Sculco PK, Flevas DA, Jerabek SA, Jiranek WA, Bostrom MP, Haddad FS, Fehring TK, Gonzalez Della Valle A, Berry DJ, Brenneis M, Bornes TD, Rojas Marcos CE, Wright TM, Sculco TP. Management of Bone Loss in Revision Total Knee Arthroplasty: An International Consensus Symposium. HSS J 2024; 20:141-181. [PMID: 39281983 PMCID: PMC11393633 DOI: 10.1177/15563316231202750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 06/20/2023] [Indexed: 09/18/2024]
Abstract
The evaluation, classification, and treatment of significant bone loss after total knee arthroplasty (TKA) continue to be a complex and debated topic in revision TKA (rTKA). Despite the introduction of new evidence and innovative technologies aimed at addressing the approach and care of severe bone loss in rTKA, there is no single document that systematically incorporates these newer surgical approaches. Therefore, a comprehensive review of the treatment of severe bone loss in rTKA is necessary. The Stavros Niarchos Foundation Complex Joint Reconstruction Center Hospital for Special Surgery, dedicated to clinical care and research primarily in revision hip and knee replacement, convened a Management of Bone Loss in Revision TKA symposium on June 24, 2022. At this meeting, the 42 international invited experts were divided into groups; each group was assigned to discuss questions related to 1 of the 4 topics: (1) assessing preoperative workup and imaging, anticipated bone loss, classification system, and implant surveillance; (2) achieving durable fixation in the setting of significant bone loss in revision TKA; (3) managing patellar bone loss and the extensor mechanism in cases of severe bone loss; and (4) considering the use of complex modular replacement systems: hinges, distal femoral, and proximal tibial replacements. Each group came to consensus, when possible, based on an extensive literature review and interactive discussion on their group topic. This document reviews each these 4 areas, the consensus of each group, and directions for future research.
Collapse
Affiliation(s)
- Peter Keyes Sculco
- Hospital for Special Surgery, New York, NY, USA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Dimitrios A Flevas
- Hospital for Special Surgery, New York, NY, USA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | | | - William A Jiranek
- Department of Orthopaedics, Duke University Medical Center, Durham, NC, USA
| | | | - Fares S Haddad
- University College London Hospitals NHS Foundation Trust, London, UK
- The Bone & Joint Journal, London, UK
| | - Thomas K Fehring
- Hip & Knee Center, OrthoCarolina, Charlotte, NC, USA
- Musculoskeletal Institute, Atrium Health, Charlotte, NC, USA
| | | | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Marco Brenneis
- Hospital for Special Surgery, New York, NY, USA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Troy D Bornes
- Hospital for Special Surgery, New York, NY, USA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Carolena E Rojas Marcos
- Hospital for Special Surgery, New York, NY, USA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | | | - Thomas P Sculco
- Hospital for Special Surgery, New York, NY, USA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
2
|
Kao A, Tawse-Smith A, Ma S, Duncan WJ, Reid M, Atieh MA. Quantity and Size of Titanium Particles Released from Different Mechanical Decontamination Procedures on Titanium Discs: An In Vitro Study. Dent J (Basel) 2024; 12:123. [PMID: 38786521 PMCID: PMC11119952 DOI: 10.3390/dj12050123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 04/11/2024] [Accepted: 04/17/2024] [Indexed: 05/25/2024] Open
Abstract
Complications such as peri-implantitis could ultimately affect the survival of a dental implant. The prevention and treatment of peri-implant diseases require managing bacterial biofilm and controlling environmental risks, including the presence of pro-inflammatory titanium (Ti) particles in the peri-implant niche. Objectives included the evaluation of the size and quantity of Ti particles released from moderately roughened Ti surfaces during common mechanical surface decontamination methods. One hundred and forty moderately roughened Ti discs were divided into seven groups (n = 20 per group); six groups received mechanical decontamination procedures (ultrasonic scaling (US) with a metal tip and poly-ether-ketone (PEEK) under low and medium power settings, air-polishing with erythritol powder, and Ti brush), and the control group underwent air-water spray using a dental triplex. The rinsing solution was collected for Ti mass analysis using inductively coupled plasma mass spectrometry (ICPMS), as well as for Ti particle size and count analysis under scanning electron microscopy (SEM) with energy-dispersive spectroscopy (EDS). US metal tip instrumentation generated 34.00 ± 12.54 μg and 34.44 ± 6.08 μg of Ti under low and medium power settings, respectively. This amount of Ti generation was significantly higher than other instrumentation methods. The mean Ti particle size of the US groups ranged from 0.89 ± 0.27 μm to 1.25 ± 0.24 μm. No statistically significant difference was found in the particle size among US groups and Ti brush group (1.05 ± 0.11 μm), except for US with the PEEK tip, where a significantly smaller mean particle diameter was found at the low power setting (0.89 ± 0.27 μm). Mechanical instrumentation can produce Ti particulates and modify the implant surfaces. US using a metal tip generated the highest amount of Ti with smaller Ti size particles compared to all other commonly used mechanical surface instrumentations. The EDS analysis confirmed Ti in PEEK US tips. It can be suggested that deterioration from the PEEK US tip and Ti brush, as observed under SEM, is an additional source of Ti release during Ti surface decontamination.
Collapse
Affiliation(s)
- Anthony Kao
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Andrew Tawse-Smith
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Sunyoung Ma
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Warwick J. Duncan
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
| | - Malcolm Reid
- Department of Chemistry and Centre for Trace Element Analysis, Department of Geology, Dunedin 9054, New Zealand;
| | - Momen A. Atieh
- Sir John Walsh Research Institute, Faculty of Dentistry, 310 Great King Street, Dunedin 9016, New Zealand; (A.K.); (S.M.); (W.J.D.); (M.A.A.)
- Department of Oral Diagnostics and Surgical Sciences, Hamdan Bin Mohammed College of Dental Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai P.O. Box 505055, United Arab Emirates
- School of Dentistry, University of Jordan, Amman 11942, Jordan
| |
Collapse
|
3
|
Mccullough JA, Peterson BT, Upfill-Brown AM, Hardin TJ, Hopkins JB, Soohoo NF, Clites TR. Compliant Intramedullary Stems for Joint Reconstruction. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2024; 12:314-327. [PMID: 38486844 PMCID: PMC10939320 DOI: 10.1109/jtehm.2024.3365305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 02/02/2024] [Accepted: 02/09/2024] [Indexed: 03/17/2024]
Abstract
The longevity of current joint replacements is limited by aseptic loosening, which is the primary cause of non-infectious failure for hip, knee, and ankle arthroplasty. Aseptic loosening is typically caused either by osteolysis from particulate wear, or by high shear stresses at the bone-implant interface from over-constraint. Our objective was to demonstrate feasibility of a compliant intramedullary stem that eliminates over-constraint without generating particulate wear. The compliant stem is built around a compliant mechanism that permits rotation about a single axis. We first established several models to understand the relationship between mechanism geometry and implant performance under a given angular displacement and compressive load. We then used a neural network to identify a design space of geometries that would support an expected 100-year fatigue life inside the body. We additively manufactured one representative mechanism for each of three anatomic locations, and evaluated these prototypes on a KR-210 robot. The neural network predicts maximum stress and torsional stiffness with 2.69% and 4.08% error respectively, relative to finite element analysis data. We identified feasible design spaces for all three of the anatomic locations. Simulated peak stresses for the three stem prototypes were below the fatigue limit. Benchtop performance of all three prototypes was within design specifications. Our results demonstrate the feasibility of designing patient- and joint-specific compliant stems that address the root causes of aseptic loosening. Guided by these results, we expect the use of compliant intramedullary stems in joint reconstruction technology to increase implant lifetime.
Collapse
Affiliation(s)
- John A Mccullough
- Department of Mechanical and Aerospace EngineeringUniversity of California Los Angeles Los Angeles CA 90095 USA
| | - Brandon T Peterson
- David Geffen School of MedicineUniversity of California Los Angeles Los Angeles CA 90095 USA
| | | | - Thomas J Hardin
- Material, Physical, and Chemical Sciences CenterSandia National Laboratories Albuquerque NM 87123 USA
| | - Jonathan B Hopkins
- Department of Mechanical and Aerospace EngineeringUniversity of California Los Angeles Los Angeles CA 90095 USA
| | - Nelson F Soohoo
- David Geffen School of MedicineUniversity of California Los Angeles Los Angeles CA 90095 USA
| | - Tyler R Clites
- Department of Mechanical and Aerospace EngineeringUniversity of California Los Angeles Los Angeles CA 90095 USA
- Department of Orthopaedic SurgeryUniversity of California Los Angeles Los Angeles CA 90095 USA
| |
Collapse
|
4
|
Keiderling L, Rosendorf J, Owens CE, Varadarajan KM, Hart AJ, Schwab J, Tallman TN, Ghaednia H. Comparing machine learning algorithms for non-invasive detection and classification of failure in piezoresistive bone cement via electrical impedance tomography. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:124103. [PMID: 38100565 DOI: 10.1063/5.0131671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 11/21/2023] [Indexed: 12/17/2023]
Abstract
At an estimated cost of $8 billion annually in the United States, revision surgeries to total joint replacements represent a substantial financial burden to the health care system and a tremendous mental and physical burden on patients and their caretakers. Fixation failures, such as implant loosening, wear, and mechanical instability of the poly(methyl methacrylate) (PMMA) cement, which bonds the implant to the bone, are the main causes of long-term implant failure. Early and accurate diagnosis of cement failure is critical for developing novel therapeutic strategies and reducing the high risk of a misjudged revision. Unfortunately, prevailing imaging modalities, notably plain radiographs, struggle to detect the precursors of implant failure and are often interpreted incorrectly. Our prior work has shown that the modification of PMMA bone cement with low concentrations of conductive fillers makes it piezoresistive and therefore self-sensing. When combined with a conductivity imaging modality such as electrical impedance tomography (EIT), it is possible to monitor load transfer across the PMMA using cost-effective, physiologically benign, non-contact, and real-time electrical measurements. Despite the ability of EIT for monitoring load transfer across self-sensing PMMA bone cement, it is unable to accurately characterize failure mechanisms. Overcoming this challenge is critical to the success of this technology in practice. Therefore, we herein expand upon our previous results by integrating machine learning techniques with EIT for cement condition characterization with the goal of establishing the feasibility of even off-the-shelf machine learning algorithms to address this important problem. We survey a wide variety of different machine learning algorithms for application to this problem, including neural networks on voltage readings of an EIT phantom for tracking the spatial position of a sample, specifying defect orientation within a sample, and classifying defect types, including cracks and delaminations. In addition, we explore the utilization of principal component analysis (PCA) for pre-treating impedance signals in each of these problems. Within the tested algorithms, our results show clear advantages of neural networks, support vector machines, and K-nearest neighbor algorithms for interpreting EIT signals. We also show that PCA is an effective addition to machine learning. These preliminary results demonstrate that the combination of smart materials, EIT, and machine learning may be a powerful instrumentation tool for diagnosing the origin and evolution of mechanical failure in joint replacements.
Collapse
Affiliation(s)
- L Keiderling
- Department of Orthopaedic Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - J Rosendorf
- Department of Orthopaedic Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - C E Owens
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - K M Varadarajan
- Department of Orthopaedic Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - A J Hart
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - J Schwab
- Department of Orthopaedic Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - T N Tallman
- School of Aeronautics and Astronautics, Purdue University, West Lafayette, Indiana 47907, USA
| | - H Ghaednia
- Department of Orthopaedic Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| |
Collapse
|
5
|
Wang B, Guo Y, Xu J, Zeng F, Ren T, Guo W. Efficacy of bone defect therapy involving various surface treatments of titanium alloy implants: an in vivo and in vitro study. Sci Rep 2023; 13:20116. [PMID: 37978333 PMCID: PMC10656537 DOI: 10.1038/s41598-023-47495-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 11/14/2023] [Indexed: 11/19/2023] Open
Abstract
Multiple surface treatment methods for titanium alloy prostheses, widely used in orthopedics, are available; however, these can affect bone integration and regeneration efficiency. In this study, through cell and animal experiments, we devised seven bone implant categories of Ti6Al4V based on surface preparation and post-processing technology (polishing, grit-blasting, fine titanium spraying, coarse titanium spraying, electron beam melting [EBM] printing, selective laser melting [SLM] printing, and post-processed SLM printing) and imaged each microscopic surface structure with a scanning electron microscope (SEM). Mechanical testing revealed excessive post-processing damaged the mechanical properties of the implants. In vitro, human bone marrow mesenchymal stem cells (hBMSCs) were cultured with implants, and the morphology of the cells adhering to the implant surface was observed using SEM and confocal laser scanning microscopy. Cell Counting Kit-8 (CCK-8) semi-quantitatively determined cell activity, indirectly reflecting the proliferation of hBMSCs. Alizarin red and alkaline phosphatase experiments assessed osteogenic differentiation. In vivo, experiments utilized the New Zealand rabbit femoral condyle bone defect model to assess bone regeneration and integration using micro-computed tomography, Van Giesen staining, and Masson staining. We found that 3D-printed implants with regular pore structures were more conducive to hBMSC osteogenic differentiation, while the presence of metal powder on NPT-SLM-printed implants hindered such differentiation. The post-treatment SLM scaffold surface may have some residual semi-melted powder; however, these powder residues have no significant effect on cell activity and differentiation. Surface treatment (grit-blasting and titanium spraying) of planar structures can enhance hBMSC adhesion but does not necessarily promote their differentiation. The framework structure of 3D printing may affect the osteogenic differentiation of hBMSCs, and for SLM-printed implants, excessive pursuit of a "powderless" state will damage the mechanical properties of the implant.
Collapse
Affiliation(s)
- Boyang Wang
- Musculoskeletal Tumor Center, Peking University People's Hospital, No. 11 Xizhimen South Street, Beijing, 100044, People's Republic of China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China
| | - Yu Guo
- Musculoskeletal Tumor Center, Peking University People's Hospital, No. 11 Xizhimen South Street, Beijing, 100044, People's Republic of China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China
| | - Jiuhui Xu
- Musculoskeletal Tumor Center, Peking University People's Hospital, No. 11 Xizhimen South Street, Beijing, 100044, People's Republic of China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China
| | - Fanwei Zeng
- Musculoskeletal Tumor Center, Peking University People's Hospital, No. 11 Xizhimen South Street, Beijing, 100044, People's Republic of China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China
| | - Tingting Ren
- Musculoskeletal Tumor Center, Peking University People's Hospital, No. 11 Xizhimen South Street, Beijing, 100044, People's Republic of China
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China
| | - Wei Guo
- Musculoskeletal Tumor Center, Peking University People's Hospital, No. 11 Xizhimen South Street, Beijing, 100044, People's Republic of China.
- Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, People's Republic of China.
| |
Collapse
|
6
|
Albahkali T, Abdo HS, Salah O, Fouly A. Adaptive Neuro-Fuzzy-Based Models for Predicting the Tribological Properties of 3D-Printed PLA Green Composites Used for Biomedical Applications. Polymers (Basel) 2023; 15:3053. [PMID: 37514443 PMCID: PMC10383854 DOI: 10.3390/polym15143053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 07/30/2023] Open
Abstract
Tribological performance is a critical aspect of materials used in biomedical applications, as it can directly impact the comfort and functionality of devices for individuals with disabilities. Polylactic Acid (PLA) is a widely used 3D-printed material in this field, but its mechanical and tribological properties can be limiting. This study focuses on the development of an artificial intelligence model using ANFIS to predict the wear volume of PLA composites under various conditions. The model was built on data gathered from tribological experiments involving PLA green composites with different weight fractions of date particles. These samples were annealed for different durations to eliminate residual stresses from 3D printing and then subjected to tribological tests under varying normal loads and sliding distances. Mechanical properties and finite element models were also analyzed to better understand the tribological results and evaluate the load-carrying capacity of the PLA composites. The ANFIS model demonstrated excellent compatibility and robustness in predicting wear volume, with an average percentage error of less than 0.01% compared to experimental results. This study highlights the potential of heat-treated PLA green composites for improved tribological performance in biomedical applications.
Collapse
Affiliation(s)
- Thamer Albahkali
- Mechanical Engineering Department, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia;
- The King Salman Center for Disability Research, Riyadh 11421, Saudi Arabia
| | - Hany S. Abdo
- Center of Excellence for Research in Engineering Materials (CEREM), Deanship of Scientific Research, King Saud University, Riyadh 11421, Saudi Arabia;
- Mechanical Design and Materials Department, Faculty of Energy Engineering, Aswan University, Aswan 81521, Egypt
| | - Omar Salah
- Department of Mechatronics, Faculty of Engineering, Assuit University, Assuit 71515, Egypt;
| | - Ahmed Fouly
- Mechanical Engineering Department, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia;
- Department of Production Engineering and Mechanical Design, Faculty of Engineering, Minia University, Minia 61519, Egypt
| |
Collapse
|
7
|
Tátrai M, Halasi T, Tállay A, Tátrai A, Pavlik A. Low Femoral Tunnel Widening Incidence Rate After ACL Reconstruction Using Patellar Tendon Graft with Press-Fit Fixation. Indian J Orthop 2023; 57:596-602. [PMID: 37006732 PMCID: PMC10050510 DOI: 10.1007/s43465-023-00836-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 01/26/2023] [Indexed: 03/30/2023]
Abstract
Abstract
Background
Femoral tunnel widening after ACL reconstruction is a common phenomenon. We hypothesized that using a patellar tendon graft with a press-fit fixation technique without any fixation device reduces the incidence of femoral tunnel widening.
Methods
This study was conducted on 467 patients with ACL surgery between 2003 and 2015. Two hundred and nineteen of them had an ACL surgery with patellar tendon (PT) graft, and two hundred and forty-eight of them with hamstring tendon (HS). Exclusion criteria were history of previous ACL reconstruction of either knee, multiple ligament injury, or evidence of osteoarthritis on radiographs. The femoral tunnels were measured on the anteroposterior (ap) and lateral radiographs 6 months after the operation. Two independent orthopedic surgeons measured all radiographs twice and recorded the tunnel widenings. We hypothesized that using an implant-free press-fit technique with PT graft can reduce the femoral tunnel widening incidence rate.
Results
The mean incidence rate of the tunnel widening in the HS group was, on the AP and the lateral femoral views, 88% (n = 217) and 83% (n = 205), while in the PT group, 17% (n = 37) and 2% (n = 4), respectively. There was a significant difference both on AP and lateral radiographs (HS vs. PT: fem. AP: 89% vs. 17% p < 0.001; HS vs. PT: fem. lat: 84% vs. 2% p < 0.001).
Conclusion
The femoral tunnel widening incidence rate during an ACL reconstruction is significantly less when using PT tendon with femoral press-fit fixation than when using HT tendon with suspensory fixation method.
Collapse
|
8
|
Kim YH, Park JW, Jang YS, Kim EJ. Is Highly Cross-Linked Polyethylene Safe for Use in High-Flexion Posterior Stabilized Total Knee Arthroplasty? J Arthroplasty 2023; 38:286-292. [PMID: 36028177 DOI: 10.1016/j.arth.2022.08.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 08/11/2022] [Accepted: 08/12/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Application of highly cross-linked polyethylene (HXLPE) to a posterior cruciate-substituting total knee arthroplasty (TKA) might add the risk of fracture and failure of the tibial polyethylene insert. The purpose of this study is to evaluate the long-term (up to 19 years) clinical and radiographic results of posterior cruciate-substituting TKAs with HXLPE or conventional polyethylene. METHODS This study analyzed the results of 1,217 patients (444 men and 773 women; mean age of 65 ± 7 years, range, 31-85) (2,434 knees) who had received a NexGen LPS-Flex prosthesis with a conventional tibial insert in one knee and the same prosthesis with an HXLPE tibial insert in the contralateral knee. The mean duration of follow-up was 17 years (range, 15-19). RESULTS The 2 groups did not differ significantly (P > .05) with regard to the clinical and radiographic results. No knee in either group had a fracture of the tibial polyethylene post or failure of the locking mechanism of the tibial polyethylene insert or osteolysis. Twenty-eight knees (2.3%) in the HXLPE group and 26 knees (2.1%) in the conventional polyethylene group were revised. The estimated survival rate at 17 years was 97.7% in the HXLPE group and 97.9% in the conventional polyethylene group. CONCLUSION The data suggest that clinical and radiographic findings at a mean of 17 years after posterior cruciate-substituting TKA are the same for patients treated with HXLPE and those treated with conventional polyethylene.
Collapse
Affiliation(s)
- Young-Hoo Kim
- The Joint Replacement Center of Seoul Metropolitan SeoNam Hospital, Seoul, Republic of Korea
| | - Jang-Won Park
- Department of Orthopeadic Surgery, Ewha Womans University, Seoul Hospital, Seoul, Republic of Korea
| | - Young-Soo Jang
- The Joint Replacement Center of Seoul Metropolitan SeoNam Hospital, Seoul, Republic of Korea
| | - Eun-Jung Kim
- The Joint Replacement Center of Seoul Metropolitan SeoNam Hospital, Seoul, Republic of Korea
| |
Collapse
|
9
|
Zhou F, Zhang G, Wu Y, Xiong Y. Inflammasome Complexes: Crucial mediators in osteoimmunology and bone diseases. Int Immunopharmacol 2022; 110:109072. [DOI: 10.1016/j.intimp.2022.109072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Revised: 06/15/2022] [Accepted: 07/14/2022] [Indexed: 11/05/2022]
|
10
|
Evaluating the Performance of 3D-Printed PLA Reinforced with Date Pit Particles for Its Suitability as an Acetabular Liner in Artificial Hip Joints. Polymers (Basel) 2022; 14:polym14163321. [PMID: 36015578 PMCID: PMC9416500 DOI: 10.3390/polym14163321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/10/2022] [Accepted: 08/12/2022] [Indexed: 11/21/2022] Open
Abstract
Off-the-shelf hip joints are considered essential parts in rehabilitation medicine that can help the disabled. However, the failure of the materials used in such joints can cause individual discomfort. In support of the various motor conditions of the influenced individuals, the aim of the current research is to develop a new composite that can be used as an acetabular liner inside the hip joint. Polylactic acid (PLA) can provide the advantage of design flexibility owing to its well-known applicability as a 3D printed material. However, using PLA as an acetabular liner is subject to limitations concerning mechanical properties. We developed a complete production process of a natural filler, i.e., date pits. Then, the PLA and date pit particles were extruded for homogenous mixing, producing a composite filament that can be used in 3D printing. Date pit particles with loading fractions of 0, 2, 4, 6, 8, and 10 wt.% are dispersed in the PLA. The thermal, physical, and mechanical properties of the PLA–date pit composites were estimated experimentally. The incorporation of date pit particles into PLA enhanced the compressive strength and stiffness but resulted in a reduction in the elongation and toughness. A finite element model (FEM) for hip joints was constructed, and the contact stresses on the surface of the acetabular liner were evaluated. The FEM results showed an enhancement in the composite load carrying capacity, in agreement with the experimental results.
Collapse
|
11
|
Does Focal Osteolysis in a PRECICE Stryde Intramedullary Lengthening Nail Resolve after Explantation? CHILDREN 2022; 9:children9060860. [PMID: 35740797 PMCID: PMC9221827 DOI: 10.3390/children9060860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/01/2022] [Accepted: 06/05/2022] [Indexed: 11/30/2022]
Abstract
Concerns surrounding osteolysis near and around the modular junction of a stainless-steel intramedullary lengthening rod prompted a manufacturer recall from the United States market in early 2021. These actions were preceded by similar steps taken in Europe. A concomitant review of stainless-steel lengthenings at our institution demonstrated signs of adverse tissue reaction including periosteal reaction and osteolysis at the modular junction and/or male-sided locking screws. Nearly half of our patients presented with these findings on radiographic images. At the time of the previous review, only half of the nearly 60 implanted stainless-steel devices met a 6-month follow-up. At this juncture, many patients have had their devices explanted. Given the suspected adverse tissue reactions caused by a component of the internal device, we sought to examine the rate of osteolysis post-explantation following removal of a stainless-steel nail. We reviewed a consecutive series of patients who underwent implantation of a stainless-steel limb lengthening device in the femur and/or tibia at a single institution between December 2018 and December 2020. Patients were included if their device was explanted. Periosteal reaction and osteolysis was classified according to a novel and validated classification system, as analyzed by five fellowship-trained surgeons. In addition, changes observed prior to explantation were tracked post-explantation to assess for resolution. The incidence of periosteal reaction and osteolysis prior to explantation was 22/57 (39%) and 15/57 (26%), respectively. Of the 15 patients with osteolysis pre-explantation, 14 patients’ implants were explanted. Of these, eight patients had available follow-up films. Two patients were identified as having partial osteolysis resolution at mean 1-year follow-up, while six patients were identified as having complete osteolysis at mean 18-months follow-up. Periosteal tissue reaction and osteolysis largely resolved following explantation in a subset of patients. These results provide further support to the claim that the stainless-steel device contributed to the changes seen. Further follow-up is warranted to examine the longer-term effects of adverse tissue reaction in this patient population.
Collapse
|
12
|
Wang N, Meenashisundaram GK, Kandilya D, Fuh JYH, Dheen ST, Kumar AS. A biomechanical evaluation on Cubic, Octet, and TPMS gyroid Ti6Al4V lattice structures fabricated by selective laser melting and the effects of their debris on human osteoblast-like cells. BIOMATERIALS ADVANCES 2022; 137:212829. [PMID: 35929262 DOI: 10.1016/j.bioadv.2022.212829] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 04/20/2022] [Accepted: 04/23/2022] [Indexed: 06/15/2023]
Abstract
Lattice structures are widely used in orthopedic implants due to their unique features, such as high strength-to-weight ratios and adjustable biomechanical properties. Based on the type of unit cell geometry, lattice structures may be classified into two types: strut-based structures and sheet-based structures. In this study, strut-based structures (Cubic & Octet) and sheet-based structure (triply periodic minimal surface (TPMS) gyroid) were investigated. The biomechanical properties of the three different Ti6Al4V lattice structures fabricated by selective laser melting (SLM) were investigated using room temperature compression testing. Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) were used to check the 3D printing quality with regards to defects and quantitative compositional information of 3D printed parts. Experimental results indicated that TPMS gyroid has superior biomechanical properties when compared to Cubic and Octet. Also, TPMS gyroid was found to be less affected by the variations in relative density. The biocompatibility of Ti6Al4V lattice structures was validated through the cytotoxicity test with human osteoblast-like SAOS2 cells. The debris generated during the degradation process in the form of particles and ions is among the primary causes of implant failure over time. In this study, Ti6Al4V particles with spherical and irregular shapes having average particle sizes of 36.5 μm and 28.8 μm, respectively, were used to mimic the actual Ti6Al4V particles to understand their harmful effects better. Also, the effects and amount of Ti6Al4V ions released after immersion within the cell culture media were investigated using the indirect cytotoxicity test and ion release test.
Collapse
Affiliation(s)
- Niyou Wang
- Department of Mechanical Engineering, 9 Engineering Drive 1, #07-08 Block EA, National University of Singapore, 117575, Singapore
| | | | - Deepika Kandilya
- Department of Anatomy, 4 Medical Drive, MD10, Yong Loo Lin School of Medicine, National University of Singapore, 117594, Singapore
| | - Jerry Ying Hsi Fuh
- Department of Mechanical Engineering, 9 Engineering Drive 1, #07-08 Block EA, National University of Singapore, 117575, Singapore
| | - S Thameem Dheen
- Department of Anatomy, 4 Medical Drive, MD10, Yong Loo Lin School of Medicine, National University of Singapore, 117594, Singapore
| | - A Senthil Kumar
- Department of Mechanical Engineering, 9 Engineering Drive 1, #07-08 Block EA, National University of Singapore, 117575, Singapore.
| |
Collapse
|
13
|
GSK-3β suppression upregulates Gli1 to alleviate osteogenesis inhibition in titanium nanoparticle-induced osteolysis. J Nanobiotechnology 2022; 20:148. [PMID: 35305665 PMCID: PMC8934501 DOI: 10.1186/s12951-022-01351-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2021] [Accepted: 03/03/2022] [Indexed: 01/08/2023] Open
Abstract
Wear particle-induced periprosthetic osteolysis (PPO) have become a major reason of joint arthroplasty failure and secondary surgery following joint arthroplasty and thus pose a severe threat to global public health. Therefore, determining how to effectively suppress particle-induced PPO has become an urgent problem. The pathological mechanism involved in the PPO signaling cascade is still unclear. Recently, the interaction between osteogenic inhibition and wear particles at the implant biological interface, which has received increasing attention, has been revealed as an important factor in pathological process. Additionally, Hedgehog (Hh)-Gli1 is a crucial signaling cascade which was regulated by multiple factors in numerous physiological and pathological process. It was revealed to exert a crucial part during embryonic bone development and metabolism. However, whether Hh-Gli1 is involved in wear particle-induced osteogenic inhibition in PPO remains unknown. Our present study explored the mechanism by which the Hh-Gli1 signaling cascade regulates titanium (Ti) nanoparticle-induced osteolysis. We found that Hh-Gli1 signaling was dramatically downregulated upon Ti particle treatment. Mechanistically, glycogen synthesis kinase 3β (GSK-3β) activation was significantly increased in Ti particle-induced osteogenic inhibition via changes in GSK-3β phosphorylation level and was found to participate in the posttranslational modification and degradation of the key transcription factor Gli1, thus decreasing the accumulation of Gli1 and its translocation from the cytoplasm to the nucleus. Collectively, these findings suggest that the Hh-Gli1 signaling cascade utilizes a GSK3β-mediated mechanism and may serve as a rational new therapeutic target against nanoparticle-induced PPO.
Collapse
|
14
|
Marx D, Papini M, Towler M. In vitro immunomodulatory effects of novel strontium and zinc-containing GPCs. Biomed Mater Eng 2022; 33:377-391. [PMID: 35180104 DOI: 10.3233/bme-211346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Glass polyalkenoate cements (GPCs) are bio-adhesives which consist of ionomeric glass particles embedded in a poly-salt matrix. These materials have been used in dentistry and orthodontics extensively but are presently being optimized as bone putties for orthopedic applications. OBJECTIVE This study utilized a patented ionomeric glass (mole fraction: SiO2:0.48, ZnO:0.36, CaO:0.12, SrO:0.04) to formulate two GPCs: GPC A (<45 μm particle size glass) and GPC B (45 μm-63 μm). These formulations were previously assessed for their effect on osteoblast viability and osteogenic function. However, the immunomodulatory effects of GPC A and B have not previously been investigated. METHOD Non-toxic concentrations of (a) GPC dissolution products and (b) fragmented GPC particles were tested for their ability to affect the secretion of cytokines (TNF-α, IL-1β, IL-6 and IL-10) by rat peripheral blood mononuclear cells (PBMCs), in the presence or absence of the stimulant liposaccharide (LPS). Additionally, the ionic concentrations of Sr, Zn, Ca, and Si were measured in GPC ionic extracts, and the size, shape and concentration of fragmented GPC particles in deionized water were characterized using an optical microscope-based particle analyzer. RESULTS The results showed that GPC A ionic products reduced the concentration of TNF-α secreted by stimulated cells compared with cells stimulated in the absence of GPC products. Interestingly, the particles released from GPC A significantly increased the secretion of both TNF-α and IL-6 from unstimulated cells, compared to control cells. CONCLUSION Neither GPC B ionic products nor released particles were found to be biologically active with respect to PBMC cytokine secretion.
Collapse
Affiliation(s)
- Daniella Marx
- Department of Biomedical Engineering, Ryerson University, Toronto, ON, Canada.,Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, ON, Canada
| | - Marcello Papini
- Department of Biomedical Engineering, Ryerson University, Toronto, ON, Canada.,Department of Mechanical Engineering, Ryerson University, Toronto, ON, Canada
| | - Mark Towler
- Department of Biomedical Engineering, Ryerson University, Toronto, ON, Canada.,Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, ON, Canada.,Department of Mechanical Engineering, Ryerson University, Toronto, ON, Canada
| |
Collapse
|
15
|
De Meurechy N, Aktan MK, Boeckmans B, Huys S, Verwilghen DR, Braem A, Mommaerts MY. Surface wear in a custom manufactured temporomandibular joint prosthesis. J Biomed Mater Res B Appl Biomater 2022; 110:1425-1438. [PMID: 35088936 PMCID: PMC9306732 DOI: 10.1002/jbm.b.35010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 11/22/2021] [Accepted: 12/09/2021] [Indexed: 11/10/2022]
Abstract
The wear of a novel temporomandibular joint (TMJ) prosthesis was evaluated in an animal model. The prosthesis consisted of an additively manufactured titanium alloy (Ti6Al4V) mandibular condyle and glenoid fossa created through selective laser melting, with a machined vitamin E‐enriched ultra‐high molecular weight polyethylene (UHMWPE) surface attached to the fossa. Thirteen TMJ prosthesis were implanted in sheep, six of which had condylar heads coated with HadSat® diamond‐like carbon (H‐DLC). Euthanasia took place after 288 days, equaling 22 years of human mastication. Linear and volumetric wear analysis of the fossa was performed by optical scanning. The condylar head surfaces were assessed by scanning electron and confocal laser microscopy. The average linear UHMWPE wear, when combined with the coated condyle, was 0.67 ± 0.28 mm (range: 0.34–1.15 mm), not significantly differing (p = .3765, t‐test) from the non‐coated combination average (0.88 ± 0.41 mm; range: 0.28–1.48 mm). The respective mean volumetric wear volumes were 25.29 ± 11.43 mm3 and 45.85 ± 22.01 mm3, not significantly differing (p = .1448, t‐test). Analysis of the coated condylar surface produced a mean Ra of 0.12 ± 0.04 μm and Sa of 0.69 ± 0.07 μm. The non‐coated condylar surface measured a mean Ra of 0.28 ± 0.17 μm and Sa of 2.40 ± 2.08 μm. Both Sa (p = .0083, Mann–Whitney U test) and Ra (p = .0182, Mann–Whitney U test), differed significantly. The prosthesis exhibits acceptable wear resistance and addition of the H‐DLC‐coating significantly improved long‐term condylar surface smoothness.
Collapse
Affiliation(s)
- Nikolas De Meurechy
- European Face Centre, Universitair Ziekenhuis Brussel, Brussels, Belgium.,Doctoral School of Life Sciences and Medicine, Vrije Universiteit Brussel, Brussels, Belgium
| | | | - Bart Boeckmans
- Department of Mechanical Engineering, KU Leuven, Heverlee, Belgium.,Flanders Make, Heverlee, Belgium
| | - Stijn Huys
- Department of Mechanical Engineering, KU Leuven, Heverlee, Belgium
| | - Denis R Verwilghen
- Sydney School of Veterinary Sciences, Faculty of Science, University of Sydney, Sydney, Australia
| | - Annabel Braem
- Department of Materials Engineering, KU Leuven, Heverlee, Belgium
| | - Maurice Y Mommaerts
- European Face Centre, Universitair Ziekenhuis Brussel, Brussels, Belgium.,Doctoral School of Life Sciences and Medicine, Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
16
|
Bistolfi A, Giustra F, Bosco F, Faccenda C, Viotto M, Sabatini L, Berchialla P, Sciannameo V, Graziano E, Massè A. Comparable results between crosslinked polyethylene and conventional ultra-high molecular weight polyethylene implanted in total knee arthroplasty: systematic review and meta-analysis of randomised clinical trials. Knee Surg Sports Traumatol Arthrosc 2022; 30:3120-3130. [PMID: 35182171 PMCID: PMC9418273 DOI: 10.1007/s00167-022-06879-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/14/2021] [Accepted: 01/12/2022] [Indexed: 12/17/2022]
Abstract
PURPOSE Total knee arthroplasty (TKA) has experienced exponential growth over the last decade, including increasingly younger patients with high functional demands. Highly crosslinked polyethylene (HXLPE) has been proven effective in reducing osteolysis and loosening revisions while improving long-term survival and performance in total hip arthroplasty; nevertheless, this superiority is not demonstrated in TKA. The aim of this systematic review and meta-analysis was to examine whether HXLPE improved overall survival and postoperative functional and radiological outcomes compared to conventional polyethylene (CPE) in TKA. METHODS According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline, a literature search of five databases (PubMed, Medline, Scopus, Science Direct and Embase) was made. A PICOS model was performed. The initial screening identified 2541 studies. Each eligible clinical article was analysed according to the Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence (LoE). Only randomised clinical trials (RCTs) of LoE 1 and 2 were included. The methodological quality of the articles was assessed using the Risk of Bias 2 (RoB 2) tool. RESULTS Six clinical studies were included in the final study. This systematic review and meta-analysis were registered on the International Prospective Register of Systematic Reviews (PROSPERO). A total of 2285 knees were included. Eight outcomes (total reoperations, reoperations for prosthesis loosening and infections, radiolucent lines, osteolysis, mechanical failure, postoperative KSS knee score and function score) were analysed. For none of them, a statistically significant difference was found about the superiority of HXLPE over CPE (p > 0.05). CONCLUSIONS There were no statistically significant differences between HXLPE and CPE for TKA concerning clinical, radiological, and functional outcomes; nevertheless, HXLPE did not show higher failure rates or complications and can be safely used for TKA. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Alessandro Bistolfi
- Orthopaedics and Traumatology, Ospedale Cardinal Massaia Asti, via Conte Verde 125, 14100 Asti, Italy
| | | | | | | | | | - Luigi Sabatini
- grid.432329.d0000 0004 1789 4477AO Città della Salute e della Scienza, Turin, Italy
| | - Paola Berchialla
- grid.7605.40000 0001 2336 6580Department of Clinical and Biological Sciences, University of Torino, Turin, Italy
| | - Veronica Sciannameo
- grid.7605.40000 0001 2336 6580Department of Clinical and Biological Sciences, University of Torino, Turin, Italy
| | - Eugenio Graziano
- Orthopaedics and Traumatology, Ospedale Cardinal Massaia Asti, via Conte Verde 125, 14100 Asti, Italy
| | - Alessandro Massè
- University of the Studies of Turin, Turin, Italy ,grid.432329.d0000 0004 1789 4477AO Città della Salute e della Scienza, Turin, Italy
| |
Collapse
|
17
|
Li H, Hu Y, Zeng M, Yang J, Fan X, Wang Y, Xie J. Exosomes From Human Urine-Derived Stem Cells Encapsulated Into PLGA Nanoparticles for Therapy in Mice With Particulate Polyethylene-Induced Osteolysis. Front Med (Lausanne) 2021; 8:781449. [PMID: 34938750 PMCID: PMC8685253 DOI: 10.3389/fmed.2021.781449] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 11/17/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Periprosthetic osteolysis is the primary reason for arthroplasty failure after total joint replacement because of the generation of wear particles and subsequent bone erosion around the prosthesis, which leads to aseptic loosening. Periprosthetic osteolysis is often treated with revision surgery because of the lack of effective therapeutic agents. As key messengers of intercellular interactions, exosomes can be independently used as therapeutic agents to promote tissue repair and regeneration. In this study, we fabricated poly(lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) that carry exosomes derived from human urine stem cells (USC-Exos) and explored their effects on polyethylene-induced osteolysis. Methods: USCs were identified by multipotent differentiation and flow cytometry analyses. USC-Exos were isolated and identified by transmission electron microscopy (TEM), dynamic light scattering (DLS), and western blotting. PLGA microspheres containing USC-Exos were fabricated to synthesize NPs using the mechanical double-emulsion method. The obtained NPs were characterized in terms of stability, toxicity, exosome release, and cell uptake. Then, these NPs were implanted into the murine air pouch model, and their effects on polyethylene-induced osteolysis were evaluated by microcomputed tomography (micro-CT) and histological analyses. Results: The average NP diameter was ~282 ± 0.4 nm, and the zeta potential was -2.02 ± 0.03 mV. After long-term storage at room temperature and 4°C, the NP solution was stable without significant coaggregation. In vitro release profiles indicated sustained release of exosomes for 12 days. In vivo, injection of NPs into the murine air pouch caused less osteolysis than that of USC-Exos, and NPs significantly reduced bone absorption, as indicated by histology and micro-CT scanning. Conclusion: Our findings suggest that USC-Exo-based PLGA NPs can prevent particulate polyethylene-induced osteolysis and bone loss.
Collapse
Affiliation(s)
- Hui Li
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China.,Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, China
| | - Yihe Hu
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China.,Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, China
| | - Min Zeng
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China.,Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, China
| | - Junxiao Yang
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China.,Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, China
| | - Xiaolei Fan
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China.,Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, China
| | - Yinan Wang
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China.,Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, China
| | - Jie Xie
- Department of Orthopedics, Xiangya Hospital, Central South University, Changsha, China.,Hunan Engineering Research Center of Biomedical Metal and Ceramic Implants, Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
18
|
Bergvinsson H, Zampelis V, Sundberg M, Flivik G. Highly cross-linked polyethylene still outperforms conventional polyethylene in THA: 10-year RSA results. Acta Orthop 2021; 92:568-574. [PMID: 34139928 PMCID: PMC8519538 DOI: 10.1080/17453674.2021.1932140] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Cup wear in total hip arthroplasty (THA) can be affected by different manufacturing processes of the polyethylene (PE). We report the long-term wear pattern differences, as well as early creep behavior, between conventional PE and highly cross-linked PE (HXLPE) liners, as measured with radiostereometry (RSA) up to 10 years. We also compare migration and clinical outcome of 2 similar uncemented cups with different backside surface roughness.Patients and methods - We included 45 patients with primary osteoarthritis. 23 received a conventional liner and 22 an HXLPE liner in a similar uncemented cup, but with a slightly rougher surface. The patients were followed up with RSA and hip-specific outcome questionnaire (HOOS) at 3 months, 1, 2, 5, and 10 years.Results - During the first 3 months both liners showed expected deformation with mean proximal head penetration of 0.39 mm (conventional PE) and 0.21 mm (HXLPE). Between 3 months and 10 years there was a difference in annual wear with 0.12 mm/year for the conventional liner and 0.02 mm/year for the HXLPE liner. The cup with rougher surface had less initial migration but both types had stabilized after 3 months. The HOOS scores improved after surgery and remained high for both groups throughout the study period.Interpretation - Up to 10 years the HXLPE has consistent lower annual wear, possibly contributing to longer survival of the THA, compared with conventional PE. All patients reported good results regardless of liner type.
Collapse
Affiliation(s)
- Halldor Bergvinsson
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden,Correspondence:
| | - Vasilis Zampelis
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| | - Martin Sundberg
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| | - Gunnar Flivik
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
19
|
Liu S, Hall DJ, Della Valle CJ, Walsh MJ, Jacobs JJ, Pourzal R. Simultaneous Characterization of Implant Wear and Tribocorrosion Debris within Its Corresponding Tissue Response Using Infrared Chemical Imaging. ACTA ACUST UNITED AC 2021; 26. [PMID: 33829077 DOI: 10.1016/j.biotri.2021.100163] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Biotribology is one of the key branches in the field of artificial joint development. Wear and corrosion are among fundamental processes which cause material loss in a joint biotribological system; the characteristics of wear and corrosion debris are central to determining the in vivo bioreactivity. Much effort has been made elucidating the debris-induced tissue responses. However, due to the complexity of the biological environment of the artificial joint, as well as a lack of effective imaging tools, there is still very little understanding of the size, composition, and concentration of the particles needed to trigger adverse local tissue reactions, including periprosthetic osteolysis. Fourier transform infrared spectroscopic imaging (FTIR-I) provides fast biochemical composition analysis in the direct context of underlying physiological conditions with micron-level spatial resolution, and minimal additional sample preparation in conjunction with the standard histopathological analysis workflow. In this study, we have demonstrated that FTIR-I can be utilized to accurately identify fine polyethylene debris accumulation in macrophages that is not achievable using conventional or polarized light microscope with histological staining. Further, a major tribocorrosion product, chromium phosphate, can be characterized within its histological milieu, while simultaneously identifying the involved immune cell such as macrophages and lymphocytes. In addition, we have shown the different spectral features of particle-laden macrophages through image clustering analysis. The presence of particle composition variance inside macrophages could shed light on debris evolution after detachment from the implant surface. The success of applying FTIR-I in the characterization of prosthetic debris within their biological context may very well open a new avenue of research in the orthopedics community.
Collapse
Affiliation(s)
- Songyun Liu
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States.,Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States
| | - Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States
| | - Craig J Della Valle
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States
| | - Michael J Walsh
- Material Sciences and Biomedical Engineering Department, University of Wisconsin-Eau Claire, Eau Claire, WI, United States
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States
| |
Collapse
|
20
|
Xu J, Li D, Cai Z, Sun H, Su B, Qiu M, Ma R. Exosomal lncRNAs NONMMUT000375.2 and NONMMUT071578.2 derived from titanium particle treated RAW264.7 cells regulate osteogenic differentiation of MC3T3-E1 cells. J Biomed Mater Res A 2020; 108:2251-2262. [PMID: 32363719 DOI: 10.1002/jbm.a.36983] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 03/25/2020] [Accepted: 04/19/2020] [Indexed: 12/19/2022]
Abstract
Periprosthetic osteolysis and the subsequent aseptic loosening can lead to the failure of joint replacement. Wear particles are well known to be the initiative cause inducing osteolysis through enhancing osteoclast-mediated bone resorption and reducing osteogenic differentiation. The purpose of this study was to investigate the effects of osteoclast-secreted exosomal long noncoding RNAs (lncRNAs) on osteogenesis in the process of particle-induced osteolysis. RAW264.7 cells were treated by titanium particles (TI). The inflammatory cytokines were increased, and expression of Receptor Activator of Nuclear Factor-κB and Nuclear factor of activated T cells c1 were also increased, indicating osteoclast differentiation occurred. The purified exosomes from RAW264.7 cells induced with TI inhibited osteogenic differentiation of MC3T3-E1 cells. RNA sequencing generated lncRNAs expression profiles (458 up-regulated and 1641 down-regulated) of the exosomes derived from RAW264.7 cells treated with TI. Based on the results of gene ontology/Kyoto Encyclopedia of Genes and Genomes analysis and quantitative real time polymerase chain reaction validation, we confirmed two candidate lncRNAs, NONMMUT000375.2 and NONMMUT071578.2. The regulation network presented that some vital genes involved in osteoclast differentiation, such as Bcl2, Wnt11, TGF-β, and Pdk1, were under the regulation of NONMMUT000375.2 and NONMMUT071578.2. Taken together, exosomes derived from TI treated RAW264.7 cells inhibit the osteogenic activity of MC3T3-E1 cells. Exosomal lncRNAs, NONMMUT000375.2 and NONMMUT071578.2 may potentially play their roles in promoting osteoclast differentiation and suppressing osteogenesis, which aggravates the osteoclastogenesis/osteogenesis imbalance.
Collapse
Affiliation(s)
- Jie Xu
- Department of Joint Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Deng Li
- Department of Joint Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Zhiqing Cai
- Department of Joint Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Hao Sun
- Department of Joint Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Baohua Su
- Department of Joint Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Meiling Qiu
- Department of Joint Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| | - Ruofan Ma
- Department of Joint Surgery, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
21
|
Lademann F, Hofbauer LC, Rauner M. The Bone Morphogenetic Protein Pathway: The Osteoclastic Perspective. Front Cell Dev Biol 2020; 8:586031. [PMID: 33178699 PMCID: PMC7597383 DOI: 10.3389/fcell.2020.586031] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 09/29/2020] [Indexed: 12/29/2022] Open
Abstract
Bone health crucially relies on constant bone remodeling and bone regeneration, both tightly controlled processes requiring bone formation and bone resorption. Plenty of evidence identifies bone morphogenetic proteins (BMP) as major players in osteoblast differentiation and thus, bone formation. However, in recent past years, researchers also increasingly reported on the pivotal role of these multi-functional growth factors in osteoclast formation and activity. This review aims to summarize the current knowledge of BMP signaling within the osteoclast lineage, its role in bone resorption, and osteoblast-osteoclast coupling. Furthermore, subsequent clinical implications for recombinant BMP therapy will be discussed in view of recent preclinical and clinical studies.
Collapse
Affiliation(s)
- Franziska Lademann
- Department of Medicine III, Technische Universität Dresden, Dresden, Germany
- Center for Healthy Aging, Technische Universität Dresden, Dresden, Germany
| | - Lorenz C. Hofbauer
- Department of Medicine III, Technische Universität Dresden, Dresden, Germany
- Center for Healthy Aging, Technische Universität Dresden, Dresden, Germany
| | - Martina Rauner
- Department of Medicine III, Technische Universität Dresden, Dresden, Germany
- Center for Healthy Aging, Technische Universität Dresden, Dresden, Germany
| |
Collapse
|
22
|
Kim YH, Park JW. Long-Term Assessment of Highly Cross-Linked and Compression-Molded Polyethylene Inserts for Posterior Cruciate-Substituting TKA in Young Patients: A Concise Follow-up of a Previous Report. J Bone Joint Surg Am 2020; 102:1623-1627. [PMID: 32590398 DOI: 10.2106/jbjs.20.00261] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The purpose of the present study was to determine the long-term clinical and radiographic results, survival rate, prevalence of osteolysis, and prevalence of fracture of the tibial polyethylene insert following total knee arthroplasty (TKA). Three hundred patients (600 knees) were included in this follow-up study. The mean age of the patients (and standard deviation) was 60.3 ± 4.3 years, and the mean duration of follow-up was 13.2 years (range, 12 to 14 years). Revision of the TKA prosthesis was performed in 7 knees (2.3%) with a compression-molded polyethylene (CPE) tibial insert and 6 knees (2%) with a highly cross-linked polyethylene (HXLPE) tibial insert. The rate of survival at 14 years was 97.7% (95% confidence interval [CI], 94%-100%) in the CPE group and 98% (95% CI, 94%-100%) in the HXLPE group with reoperation for any reason as the end point. The rate of survival at 14 years was 98% (95% CI, 94%-100%) in both groups with reoperation for mechanical failure as the end point. No knee had osteolysis or fracture of the tibial polyethylene insert. There were no between-group differences. LEVEL OF EVIDENCE:: Therapeutic Level I. See Instruction for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Young-Hoo Kim
- The Joint Replacement Center of Seoul Metropolitan SeoNam Hospital, Seoul, Republic of Korea
| | - Jang-Won Park
- The Joint Replacement Center of Ewha Womans University Seoul Hospital, Seoul, Republic of Korea
| |
Collapse
|
23
|
Yamaguchi H, Takahashi M, Sasaki K, Takada Y. Mechanical properties and microstructures of cast dental Ti-Fe alloys. Dent Mater J 2020; 40:61-67. [PMID: 32848101 DOI: 10.4012/dmj.2019-254] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Binary Ti-Fe alloys of varying concentrations of Fe between 5-25% were made, and their castings evaluated in terms of microstructures formed and mechanical properties. The aim of this study was to explore the composition of Ti-Fe alloys that offers improved wear resistance of titanium. X-ray diffraction and microstructural observation revealed that 5-7% Fe, 8-15% Fe, and 20-25% Fe consisted of α+β, single β, and β+Ti-Fe phases, respectively. The hardness of alloys with 8-13% Fe was almost equal to that of Co-Cr alloys but lower than of the other Ti-Fe alloys. Elongation of the Ti-Fe alloys was negligible. However, dimples were observed in specimen containing 7-11% Fe. Alloys with 9% Fe demonstrated the highest strength of more than 850 MPa. We believe that Ti-Fe alloys with 8-11% Fe may be applicable in development of an alloy with good wear resistance due to the exhibited properties of high hardness and ductility albeit low.
Collapse
Affiliation(s)
- Hirofumi Yamaguchi
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry.,Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry
| | - Masatoshi Takahashi
- Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry
| | - Keiichi Sasaki
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
| | - Yukyo Takada
- Division of Dental Biomaterials, Tohoku University Graduate School of Dentistry
| |
Collapse
|
24
|
Fibroblast-Like-Synoviocytes Mediate Secretion of Pro-Inflammatory Cytokines via ERK and JNK MAPKs in Ti-Particle-Induced Osteolysis. MATERIALS 2020; 13:ma13163628. [PMID: 32824426 PMCID: PMC7476030 DOI: 10.3390/ma13163628] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Revised: 08/08/2020] [Accepted: 08/14/2020] [Indexed: 12/14/2022]
Abstract
Biomaterials are designed to replace and augment living tissues in order to provide functional support to skeletal deformities. However, wear debris produced from the interfaces of metal implants initiates inflammatory bone loss, causing periprosthetic osteolysis. Lately, fibroblast-like synoviocytes (FLS) have been shown to play a role in wear-debris-induced osteolysis. Thus, here we have tried to understand the underlying mechanism of FLS involvement in wear-debris-induced osteolysis. Our results demonstrate that the effects of Ti particle (1:100 cell-to-Ti particle ratio) on FLS can induce Cox-2 expression and activate NFkB signaling. Moreover, the mRNA expression of pro-inflammatory cytokines such as IL-6, IL-8, IL-11, IL-1β, and TNFα was found to be elevated. However, among these pro-inflammatory cytokines, the mRNA and protein levels of only IL-6, IL-1β, and TNFα were found to be significantly higher. Ti particles activated extracellular signal-regulated kinase (ERK) and c-Jun N-terminal kinase (JNK) mitogen-activated protein kinases (MAPKs) as an early response in FLS. Co-inhibition of ERK and JNK signaling pathways by their specific inhibitors (PD9805 and SP600125, respectively) resulted in the suppression of mRNA and protein levels of IL-6, IL-1β, and TNFα in FLS. Taken together, targeting ERK and JNK MAPKs in FLS might provide a therapeutic option for reducing the secretion of bone-resorbing pro-inflammatory cytokines, thus preventing periprosthetic osteolysis.
Collapse
|
25
|
Gupta R, Khatri S, Malhotra A, Bachhal V, Masih GD, Kaur J. Pre-operative Joint Inflammation has no Bearing on Outcome of Arthroscopic Anterior Cruciate Ligament Reconstruction at 1-Year Follow-Up; a Prospective Study. Indian J Orthop 2020; 55:360-367. [PMID: 33927814 PMCID: PMC8046866 DOI: 10.1007/s43465-020-00150-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 05/22/2020] [Indexed: 02/04/2023]
Abstract
BACKGROUND To study the effect of pre-operative joint inflammation on clinical outcome at 1 year follow-up following ACL reconstruction surgery. METHODS Male patients, aged 18-40 years, suffering from isolated ACL injury were included. All patients were randomly divided into two groups based on the type of graft used: Group A: semitendinosus gracilis graft with preserved insertions (STG-PI), Group B: bone-patellar tendon-bone graft (BPTB). Patients were categorised based on the time of presentation after injury: (a) within 6 weeks of injury, (b) between 6 and 12 weeks of injury, (c) after 12 weeks of injury. Synovial fluid levels of Interlukin-1, Interlukin-6 and TNF-α were measured in all the ACL deficient knees by taking a joint fluid sample intra-operatively. RESULTS The total number of patients in the study was 59; 23 in group A (STG-PI) and 36 in group B (BPTB). Mean age of patients was 26 ± 5.146 years. 14 out of 59 (23.7%) patients presented within 6 weeks of injury, 16 (27.11%) patients presented between 6 and 12 weeks after injury and 29 (49.1%) patients presented after 12 weeks of injury. IL-6 levels were significantly high in group with < 6 weeks of injury than in group with > 12 weeks since injury. IL-6 had significant correlation with VAS scores, KT 1000, Lysholm knee scores and Tegner level of activity. There was no difference in outcome (pain scores, mechanical stability, Lysholm knee score and Tegner level of activity) at 1 year follow-up when patients with different time intervals since injury were compared. CONCLUSION The clinical outcome in terms of pain score, mechanical stability, functional scores and return to sporting activity is comparable, irrespective of the time since injury, at short term follow-up.
Collapse
Affiliation(s)
- Ravi Gupta
- Department of Orthopaedics and Sports Injury Centre, Government Medical College Hospital, Chandigarh, India
| | - Sourabh Khatri
- Department of Orthopaedics, AIIMS, Rishikesh, Uttarkhand 249203 India
| | - Anubhav Malhotra
- Department of Orthopaedics, Government Medical College Hospital, Chandigarh, India
| | - Vikas Bachhal
- Department of Orthopaedics, PGIMER, Chandigarh, 160012 India
| | - Gladson David Masih
- Department of Orthopaedics, Government Medical College Hospital, Chandigarh, India
| | - Jasbinder Kaur
- Department of Biochemistry, Government Medical College Hospital, Chandigarh, 160030 India
| |
Collapse
|
26
|
Jalali O, Scudday T, Fickenscher MC, Barnett S, Gorab R. Third-Generation Medium Cross-Linked Polyethylene Demonstrates Very Low Wear in Total Hip Arthroplasty. Arthroplast Today 2020; 6:316-321. [PMID: 32514421 PMCID: PMC7267711 DOI: 10.1016/j.artd.2020.04.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 02/21/2020] [Accepted: 04/07/2020] [Indexed: 02/08/2023] Open
Abstract
Background Cross-linked polyethylene (XLPE) liners have shown lower wear rates than conventional polyethylene liners in total hip arthroplasty. The primary aim of our study was to report our most recent analysis of wear rates and clinical outcomes of a third-generation XLPE liner. Secondary aims were to investigate the rate of adverse events related to mechanical failure or oxidation of this liner. Methods A series of 266 total hip arthroplasties using a specific XLPE liner were retrospectively reviewed. Radiographs were examined to determine linear and volumetric wear rates and presence of osteolysis. Clinical outcomes, revision rates, mechanical failures, and risk factors for accelerated polyethylene wear were additionally investigated. Results The mean age at the time of surgery was 65.8 years and the mean follow-up was 5.5 years. The mean linear wear rate was 0.003 mm/year and the mean volumetric wear rate was 0.42 mm3/year, and there was no evidence of osteolysis. Harris hip scores increased from 50.9 preoperatively to 96.0 at the latest follow-up. The revision rate was 0.4%, with no liner rim fractures and no liner dissociations/loosenings. Femoral head material, head size, age, body mass index, and time since implantation had no effect on wear rates. Conclusion Wear rates for this third-generation XLPE liner were low at mid-term follow-up, and no adverse sequelae of oxidation or deleterious mechanical properties were observed. This remained true regardless of femoral head size and material or patient age and body mass index. Further analysis will be necessary to ensure continued wear resistance, oxidative stability, and mechanical strength at long-term follow-up.
Collapse
Affiliation(s)
- Omid Jalali
- Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | | | | | | | | |
Collapse
|
27
|
Wilson BM, Moran MM, Meagher MJ, Ross RD, Mashiatulla M, Virdi AS, Sumner DR. Early changes in serum osteocalcin and body weight are predictive of implant fixation in a rat model of implant loosening. J Orthop Res 2020; 38:1216-1227. [PMID: 31825107 PMCID: PMC7225033 DOI: 10.1002/jor.24563] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 11/30/2019] [Indexed: 02/04/2023]
Abstract
Biomarkers are of interest to identify patients at risk for peri-implant osteolysis and aseptic loosening. We used a rat model of particle-induced peri-implant osteolysis to investigate if early changes in biomarkers were associated with subsequent implant fixation strength. Implants were placed in rat femora, which were then challenged with intra-articular knee injections of either clean polyethylene, lipopolysaccharide-doped polyethylene, or cobalt-chromium alloy particles, with particle-free vehicle serving as control (n ≥ 8 per group). Rats were weighed weekly, blood was collected at weeks 0, 3, 5, and 6, and locomotor behavior was assessed 4 days before study conclusion. Rats were euthanized 6 weeks post surgery. Week 6 serum was analyzed for five bone remodeling markers, while longitudinal serum was assessed for osteocalcin. Bone-implant contact, peri-implant trabecular architecture, and implant fixation strength were measured. Rats challenged with cobalt-chromium particles had a significant reduction in implant fixation strength compared with the vehicle-control group (P = .034). This group also had elevated serum osteocalcin (P = .005), depressed weight gain (P = .001) and less frequent rearing behavior (P = .029). Regardless of group, change in serum osteocalcin at week 3 (r = -.368; P = .046), change in weight at week 2 (r = .586; P < .001), as well as weight change at all other time intervals were associated with fixation strength. The finding that early alterations in serum osteocalcin and body weight were predictive of subsequent implant fixation strength supports continued investigation of biomarkers for early detection of peri-implant osteolysis and implant loosening. Further, change in biomarker levels was found to be more indicative of implant fixation status than any single measurement.
Collapse
Affiliation(s)
- Brittany M. Wilson
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL
| | - Meghan M. Moran
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Matthew J. Meagher
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL
| | - Ryan D. Ross
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Maleeha Mashiatulla
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL
| | - Amarjit S. Virdi
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - D. Rick Sumner
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
28
|
Nanosized Alumina Particle and Proteasome Inhibitor Bortezomib Prevented inflammation and Osteolysis Induced by Titanium Particle via Autophagy and NF-κB Signaling. Sci Rep 2020; 10:5562. [PMID: 32221318 PMCID: PMC7101404 DOI: 10.1038/s41598-020-62254-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 03/11/2020] [Indexed: 12/17/2022] Open
Abstract
Autophagy and NF-κB signaling are involving in the process of Particle Disease, which was caused by the particles released from friction interface of artificial joint, implant materials of particle reinforced composite, scaffolds for tissue engineering, or material for drug delivery. However, the biological interaction of different material particles and the mechanism of proteasome inhibitor, Bortezomib (BTZ), against Titanium (Ti) particle-induced Particle Disease remain unclear. In this study, we evaluated effect of nanosized Alumina (Al) particles and BTZ on reducing and treating the Ti particle-induced inflammatory reaction in MG-63 cells and mouse calvarial osteolysis model. We found that Al particles and BTZ could block apoptosis and NF- κB activation in osteoblasts in vitro and in a mouse model of calvarial resorption induced by Ti particles. We found that Al particles and BTZ attenuated the expression of inflammatory cytokines (IL-1β, IL-6, TNF-α). And Al prevented the IL-1β expression induced by Ti via attenuating the NF- κB activation β-TRCP and reducing the expression of Casepase-3. Expressions of autophagy marker LC3 was activated in Ti group, and reduced by Al and/not BTZ. Furthermore, the expressions of OPG were also higher in these groups than the Ti treated group. Collectively, nanosized Al could prevent autophagy and reduce the apoptosis, inflammatory and osteolysis induced by Ti particles. Our data offered a basic data for implant design when it was inevitable to use Ti as biomaterials, considering the outstanding mechanical propertie of Ti. What's more, proteasome inhibitor BTZ could be a potential therapy for wear particle-induced inflammation and osteogenic activity via regulating the activity of NF- κB signaling pathway.
Collapse
|
29
|
Hallab NJ, Jacobs JJ. Orthopedic Applications. Biomater Sci 2020. [DOI: 10.1016/b978-0-12-816137-1.00070-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
30
|
Diagnosis of the failed total hip replacement. J Clin Orthop Trauma 2020; 11:2-8. [PMID: 32001976 PMCID: PMC6985031 DOI: 10.1016/j.jcot.2019.11.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 11/28/2019] [Indexed: 12/27/2022] Open
|
31
|
Ormsby RT, Solomon LB, Stamenkov R, Findlay DM, Atkins GJ. Evidence for Gender-Specific Bone Loss Mechanisms in Periprosthetic Osteolysis. J Clin Med 2019; 9:jcm9010053. [PMID: 31878362 PMCID: PMC7019811 DOI: 10.3390/jcm9010053] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 12/13/2019] [Accepted: 12/20/2019] [Indexed: 11/22/2022] Open
Abstract
Osteolysis adjacent to total hip replacement (THR) prostheses is a major cause of their eventual failure. Periprosthetic osteolysis is associated with the production of bioactive particles, produced by the wear of articulating prosthesis surfaces. Wear particles invade the periprosthetic tissue, inducing inflammation and bone resorption. Previous studies have shown that osteocytes, the most numerous cell type in mineralised bone, can respond to wear particles of multiple orthopaedic material types. Osteocytes play important roles in bone resorption, regulating bone resorption by osteoclasts and directly through osteocytic osteolysis, also known as perilacunar remodelling. In this study, we perform a histological analysis of bone biopsies obtained from cohorts of male and female patients undergoing either primary THR surgery or revision THR surgery for aseptic loosening. The osteocyte lacunae area (Ot.Lac.Ar) and percentage lacunar area/bone area (%Ot.Lac.Ar/B.Ar) were significantly larger overall in revision THR bone than bone from similar sites in primary THR. Analysis by patient gender showed that increased Ot.Lac.Ar, indicative of increased perilacunar remodelling, was restricted to female revision samples. No significant differences in osteoclast parameters were detectable between the cohorts. These findings suggest previously unrecognised gender-specific mechanisms of bone loss in orthopaedic wear particle-induced osteolysis in humans.
Collapse
Affiliation(s)
- Renee T. Ormsby
- Biomedical Orthopaedic Research Group, Centre for Orthopaedic & Trauma Research, The University of Adelaide, Adelaide, SA 5000, Australia;
| | - Lucian B. Solomon
- Centre for Orthopaedic & Trauma Research, The University of Adelaide, Adelaide, SA 5000, Australia; (L.B.S.); (D.M.F.)
- Department of Orthopaedics & Trauma, Royal Adelaide Hospital, Adelaide, SA 5000, Australia;
| | - Roumen Stamenkov
- Department of Orthopaedics & Trauma, Royal Adelaide Hospital, Adelaide, SA 5000, Australia;
| | - David M. Findlay
- Centre for Orthopaedic & Trauma Research, The University of Adelaide, Adelaide, SA 5000, Australia; (L.B.S.); (D.M.F.)
| | - Gerald J. Atkins
- Biomedical Orthopaedic Research Group, Centre for Orthopaedic & Trauma Research, The University of Adelaide, Adelaide, SA 5000, Australia;
- Correspondence: ; Tel.: +61 883137214
| |
Collapse
|
32
|
Chang JD, Kim IS, Mansukhani SA, Sharma V, Lee SS, Yoo JH. Midterm outcome of fourth-generation ceramic-on-ceramic bearing surfaces in revision total hip arthroplasty. J Orthop Surg (Hong Kong) 2019; 26:2309499018783913. [PMID: 29945472 DOI: 10.1177/2309499018783913] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
PURPOSE The purpose of this study is to evaluate the clinical and radiologic outcomes after revision total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) bearing surfaces. METHODS A total of 52 revision THAs (28 men and 19 women) using the fourth-generation CoC bearing surfaces were retrospectively evaluated. Both acetabular cup and femoral stem were revised in all cases. The mean follow-up period was 7.3 years (range, 4.0-9.9 years). The clinical results with Harris hip score (HHS), Western Ontario McMaster Osteoarthritis Index (WOMAC), and radiologic outcomes were evaluated. RESULTS At the final follow-up examination, the average HHS was 90.4 (range, 67-100). The average WOMAC pain and physical function score were 2.8 (range, 0-12) and 16.4 (range, 0-42), respectively. Complications were observed in 10 hips (19.2%). However, there were no bearing surface-related complications, and no cases of dislocation and squeaking. Retroacetabular pelvic osteolysis without cup loosening was observed in one hip at the final follow-up. However, no hip showed radiographic signs of cup loosening, vertical or horizontal acetabular cup migrations, and changes of inclinations during the follow-up period. CONCLUSION Our data showed that clinical and radiologic outcomes after revision THA using fourth-generation CoC bearing were favorable. Hence, revision THA with the use of CoC bearing surfaces can be preferentially considered. Further studies with long-term follow-up data are warranted.
Collapse
Affiliation(s)
- Jun-Dong Chang
- 1 Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - In-Sung Kim
- 1 Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - Sameer Ajit Mansukhani
- 1 Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - Vishwas Sharma
- 1 Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea
| | - Sang-Soo Lee
- 2 Department of Orthopaedic Surgery, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Republic of Korea
| | - Je-Hyun Yoo
- 3 Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Gyeonggi-do, Republic of Korea
| |
Collapse
|
33
|
Seasoning Polymethyl Methacrylate (PMMA) Bone Cements with Incorrect Mix Ratio. MATERIALS 2019; 12:ma12193073. [PMID: 31547178 PMCID: PMC6804204 DOI: 10.3390/ma12193073] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 09/03/2019] [Accepted: 09/18/2019] [Indexed: 02/07/2023]
Abstract
Cemented joint prostheses are widely used in orthopaedic surgery; however, implants/bone bonds are known to be susceptible to aseptic loosening, particularly in the case of long-term performance. The exact mechanism of this failure is under constant examination. One of the critical factors to the final mechanical functionality of bone cement can be an incorrect mix ratio of a two-component material (powdered polymer and liquid monomer). It can result in the deterioration of the final mechanical strength properties. The paper presents the results from an experimental study on the effects of the deviation from the correct mix ratio on the moisture uptake and the compression strength of cement depending on the seasoning time in Ringer's solution. The results were subjected to statistical analysis and a mathematical model was developed.
Collapse
|
34
|
Goodman SB, Pajarinen J, Yao Z, Lin T. Inflammation and Bone Repair: From Particle Disease to Tissue Regeneration. Front Bioeng Biotechnol 2019; 7:230. [PMID: 31608274 PMCID: PMC6761220 DOI: 10.3389/fbioe.2019.00230] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Accepted: 09/06/2019] [Indexed: 12/17/2022] Open
Abstract
When presented with an adverse stimulus, organisms evoke an immediate, pre-programmed, non-specific innate immune response. The purpose of this reaction is to maintain the organism's biological integrity and function, mitigate or eradicate the injurious source, and re-establish tissue homeostasis. The initial stage of this protective reaction is acute inflammation, which normally reduces or terminates the offending stimulus. As the inflammatory reaction recedes, the stage of tissue repair and regeneration follows. If the above sequence of events is perturbed, reconstitution of normal biological form and function will not be achieved. Dysregulation of these activities may result in incomplete healing, fibrosis, or chronic inflammation. Our laboratory has studied the reaction to wear particles from joint replacements as a paradigm for understanding the biological pathways of acute and chronic inflammation, and potential translational treatments to reconstitute lost bone. As inflammation is the cornerstone for healing in all anatomical locations, the concepts developed have relevance to tissue engineering and regenerative medicine in all organ systems. To accomplish our goal, we developed novel in vitro and in vivo models (including the murine femoral continuous intramedullary particle infusion model), translational strategies including modulation of macrophage chemotaxis and polarization, and methods to interfere with key transcription factors NFκB and MyD88. We purposefully modified MSCs to facilitate bone healing in inflammatory scenarios: by preconditioning the MSCs, and by genetically modifying MSCs to first sense NFκB activation and then overexpress the anti-inflammatory pro-regenerative cytokine IL-4. These advancements provide significant translational opportunities to enhance healing in bone and other organs.
Collapse
Affiliation(s)
- Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, CA, United States.,Department of Bioengineering, Stanford University, Stanford, CA, United States.,Department of Medicine, Clinicum, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Jukka Pajarinen
- Department of Medicine, Clinicum, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Zhenyu Yao
- Orthopaedic Research Laboratories, Stanford University, Stanford, CA, United States
| | - Tzuhua Lin
- Orthopaedic Research Laboratories, Stanford University, Stanford, CA, United States
| |
Collapse
|
35
|
Osteocytes respond to particles of clinically-relevant conventional and cross-linked polyethylene and metal alloys by up-regulation of resorptive and inflammatory pathways. Acta Biomater 2019; 87:296-306. [PMID: 30690207 DOI: 10.1016/j.actbio.2019.01.047] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Revised: 01/18/2019] [Accepted: 01/24/2019] [Indexed: 02/06/2023]
Abstract
Periprosthetic osteolysis is a major cause of implant failure in total hip replacements. Aseptic loosening caused by osteolytic lesions is associated with the production of bioactive wear particles from the articulations of implants. Wear particles infiltrate the surrounding tissue of implants, promoting inflammation as well as bone resorption. Osteocytes have been shown to both regulate physiological osteoclastogenesis and directly remodel their perilacunar bone matrix by the process of osteocytic osteolysis. We hypothesise that osteocytes respond to wear debris of orthopaedic implant materials by adopting a pro-catabolic phenotype and thus contribute to periprosthetic osteolysis through the known pathways of bone loss. Osteocyte responses to particles derived from clinically relevant materials, ultra-high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (XLPE) and metal alloys, Ti6Al4V and CoCrMo, were examined in vitro in human primary osteocyte-like cultures. Osteocyte-like cells exposed to both polyethylene and metal wear particle types showed upregulated expression of catabolic markers associated with osteocytic osteolysis, MMP13, carbonic anhydrase 2 (CA2) and cathepsin K (CTSK). In addition, pro-osteoclastogenesis markers RANKL and M-CSF were induced, as well as the expression of pro-inflammatory cytokines, IL-6 and TNFα, albeit with different kinetics. These findings suggest a previously unrecognised action of wear particles of multiple orthopaedic materials on osteocytes, and suggest a multifaceted role for osteocytes in periprosthetic osteolysis. STATEMENT OF SIGNIFICANCE: This study addresses periprosthetic osteolysis, a major clinical problem leading to aseptic loosening of orthopaedic implants. It is well accepted that wear particles of polyethylene and of other implant materials stimulate the activity of bone resorbing osteoclasts. Our recent work provided evidence that commercial particles of ultra-high molecular weight polyethylene (UHMWPE) stimulated osteocytes to adopt a bone catabolic state. In this study we demonstrate for the first time that particles derived from materials in clinical use, conventional UHMWPE, highly cross-linked polyethylene (XLPE), and Ti6Al4V and CoCrMo metal alloys, all stimulate human osteocyte activities of osteocyte-regulated osteoclastogenesis, osteocytic osteolysis, proinflammatory responses, osteocyte apoptosis, albeit to varying extents. This study provides further mechanistic insight into orthopaedic wear particle mediated bone disease in terms of the osteocyte, the most abundant and key controlling cell type in bone.
Collapse
|
36
|
Tuning the tribofilm nanostructures of polymer-on-metal joint replacements for simultaneously enhancing anti-wear performance and corrosion resistance. Acta Biomater 2019; 87:285-295. [PMID: 30682423 DOI: 10.1016/j.actbio.2019.01.038] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 12/14/2018] [Accepted: 01/17/2019] [Indexed: 02/08/2023]
Abstract
Total joint replacement is currently the most successful clinical treatment for improving the life quality of individuals afflicted with end-stage osteoarthritis of knee or hip joints. However, release of wear and corrosion products from the prostheses is a critical issue causing adverse physiological responses of local issues. β-SiC nanoparticles were dispersed into polyetheretherketone (PEEK) materials and their role in tribocorrosion performance of PEEK-steel joints exposed to simulated body fluid was investigated. It is demonstrated that β-SiC nanoparticles increase greatly the wear resistance of the PEEK materials, and meanwhile mitigate significantly corrosion of the steel counterpart. It is revealed that tribochemical reactions of β-SiC nanoparticles promoted formation of a robust tribofilm having complex structures providing protection and shielding effects. The present work proposes a strategy for developing high-performance polymer-on-metal joint replacement materials of enhanced lifespan and biocompatibility via tuning interface nanostructures. STATEMENT OF SIGNIFICANCE: Adverse tissue responses to metal wear and corrosion products from metal base implants remain a challenge to surgeons and patients. We demonstrated that leaching of metal ions and release of metallic debris are well decreased via tuning interface nanostructures of metal-polymer joint bearings by dispersing β-SiC nanoparticles into polyetheretherketone (PEEK). It is identified that the addition of β-SiC greatly improves the tribological performances of the PEEK materials and mitigated corrosion of the steel. Tribo-chemistry reactions of SiC induce the formation of complex structures which provide protection and shielding effects. Nanostructures of the tribofilm were also comprehensively investigated. These novel findings proposed a potential route for designing high performance metal-polymer joint replacement materials.
Collapse
|
37
|
Gittings DJ, Dattilo JR, Hardaker W, Sheth NP. Evaluation and Treatment of Femoral Osteolysis Following Total Hip Arthroplasty. JBJS Rev 2019; 5:e9. [PMID: 28806267 DOI: 10.2106/jbjs.rvw.16.00118] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Daniel J Gittings
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
| | | | | | | |
Collapse
|
38
|
Hallab NJ, Samelko L, Hammond D. The Inflammatory Effects of Breast Implant Particulate Shedding: Comparison With Orthopedic Implants. Aesthet Surg J 2019; 39:S36-S48. [PMID: 30715176 PMCID: PMC6355107 DOI: 10.1093/asj/sjy335] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Currently, there is a dearth of information regarding the degree of particle shedding from breast implants (BIs) and what are the general biological consequences of BI debris. Thus, it is unclear to what degree BI debris compromises the long-term biological performance of BIs. For orthopedic implants, it is well established that the severity of biological reactivity to implant debris governs long-term clinical performance. Orthopedic implant particulate debris is generally in the range of 0.01 to 100 μm in diameter. Implant debris-induced bioreactivity/inflammation is mostly a peri-implant phenomenon caused by local innate immune cells (eg, macrophages) that produce proinflammatory cytokines such as tumor necrosis factor-α, interleukin-1β, interleukin-6, and prostaglandin 2 (PGE2). In orthopedics, there have been few systemic concerns associated with polymeric implant debris (like silicone) other than documented dissemination to remote organs (eg, liver, spleen, etc.) with no known associated pathogenicity. This is not true of metal implant debris where normal (well-functioning) implants can induce systemic reactions such as delayed type hypersensitivity. Diagnostic analysis of orthopedic tissues has focused on innate (macrophage mediated) and adaptive (lymphocyte-mediated hypersensitivity) immune responses. Orthopedic implant debris-associated lymphocyte cancers have not been reported in over 40 years of orthopedic literature. Adaptive immune responses such as hypersensitivity reactions to orthopedic implant debris have been dominated by certain implant types that produce specific kinds of debris (eg, metal-on-metal total joint prostheses). Orthopedic hypersensitivity responses and atypical BI bioreactivity such as BI-associated anaplastic large cell lymphoma share crossover markers for diagnosis. Differentiating normal innate immune reactivity to particles from anaplastic large cell lymphoma reactions from delayed type hypersensitivity reactions to BI-associated implant debris remains unclear but vital to patients and surgeons.
Collapse
Affiliation(s)
- Nadim James Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Lauryn Samelko
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | | |
Collapse
|
39
|
Matsui S, Majima T, Mominoki K, Hirayama H, Oshima Y, Takahashi K, Takai S. Effects of Endoprosthesis Head Material on Acetabular Cartilage Metabolism: An Animal Study Using Crossbred Pigs. J NIPPON MED SCH 2018; 85:309-314. [PMID: 30568056 DOI: 10.1272/jnms.jnms.2018_85-50] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Hip endoprosthesis is one option for the treatment of displaced femoral neck fractures and avascular necrosis of the femoral head. Few reports are available describing acetabular cartilage metabolism after endoprosthesis surgery of the hip. The purpose of this study was to compare the biological effects on cartilage between cobalt-chrome (Co-Cr) and alumina ceramic heads wherein the cartilage articulates directly. METHODS We used the acetabular cartilage from six hips of three immature crossbred pigs to examine the effects on cytokines, the amount of hyaluronic acid (HA), and cartilage mRNA expression of ceramic head and Co-Cr head endoprosthesis. Mechanical loading of materials of Co-Cr and ceramic heads was performed on the acetabular cartilage in culture media as an organ culture model. Thereafter, protein levels of cytokines (MMP-1, 3, TNF-alpha (α), Interleukin (IL)-1 alpha (α), and IL-1 beta (β)) and the amount of HA were measured from the culture media. Cartilage RNA extraction was performed, and quantitative reverse transcriptase-polymerase chain reaction was performed with primer sets for type I, II, and III collagens; aggrecan; MMP-1, 3, 13; TNF-α; and IL-1 α, IL-1 β. RESULTS Protein level of IL-1 β and amount of HA in the Co-Cr group were significantly higher than those of the Ceramic group. Type II collagen mRNA expression in the Ceramic group was significantly higher than in the Co-Cr group. IL-1 β mRNA expression was significantly higher in the Co-Cr group than in the Ceramic group. CONCLUSIONS The present study showed that ceramic bipolar produces smaller adverse effects on cartilage cells compared to Co-Cr bipolar. These results could have significant implications for implant usage not only in hip joints, but also in other joints, including the shoulder, talus and radial head.
Collapse
Affiliation(s)
- Shuhei Matsui
- Department of Orthopedic Surgery, Nippon Medical School
| | | | | | | | | | | | - Shinro Takai
- Department of Orthopedic Surgery, Nippon Medical School
| |
Collapse
|
40
|
Wu XD, Liu MM, Sun YY, Zhao ZH, Zhou Q, Kwong JSW, Xu W, Tian M, He Y, Huang W. Relationship between hospital or surgeon volume and outcomes in joint arthroplasty: protocol for a suite of systematic reviews and dose-response meta-analyses. BMJ Open 2018; 8:e022797. [PMID: 30552256 PMCID: PMC6303624 DOI: 10.1136/bmjopen-2018-022797] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Revised: 09/11/2018] [Accepted: 11/07/2018] [Indexed: 02/05/2023] Open
Abstract
INTRODUCTION Joint arthroplasty is a particularly complex orthopaedic surgical procedure performed on joints, including the hip, knee, shoulder, ankle, elbow, wrist and even digit joints. Increasing evidence from volume-outcomes research supports the finding that patients undergoing joint arthroplasty in high-volume hospitals or by high-volume surgeons achieve better outcomes, and minimum case load requirements have been established in some areas. However, the relationships between hospital/surgeon volume and outcomes in patients undergoing arthroplasty are not fully understood. Furthermore, whether elective arthroplasty should be restricted to high-volume hospitals or surgeons remains in dispute, and little is known regarding where the thresholds should be set for different types of joint arthroplasties. METHODS AND ANALYSES This is a protocol for a suite of systematic reviews and dose-response meta-analyses, which will be amended and updated in conjunction with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Protocols. Electronic databases, including PubMed and Embase, will be searched for observational studies examining the relationship between the hospital or surgeon volume and clinical outcomes in adult patients undergoing primary or revision of joint arthroplasty. We will use records management software for study selection and a predefined standardised file for data extraction and management. Quality will be assessed using the Newcastle-Ottawa Scale, and the meta-analysis, subgroup analysis and sensitivity analysis will be performed using Stata statistical software. Once the volume-outcome relationships are established, we will examine the potential non-linear relationships between hospital/surgeon volume and outcomes and detect whether thresholds or turning points exist. ETHICS AND DISSEMINATION Ethical approval is not required, because these studies are based on aggregated published data. The results of this suite of systematic reviews and meta-analyses will be submitted to peer-reviewed journals for publication. PROSPERO REGISTRATION NUMBER CRD42017056639.
Collapse
Affiliation(s)
- Xiang-Dong Wu
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Evidence-Based Perioperative Medicine 07 Collaboration Group, China
| | - Meng-Meng Liu
- Department of Pathology, Anhui Medical University, Hefei, China
| | - Ya-Ying Sun
- Department of Sports Medicine, Huashan Hospital, Fudan University, Shanghai, China
| | - Zhi-Hu Zhao
- Department of orthopaedic, Tianjin Hospital, Tianjin, China
| | - Quan Zhou
- Department of Science and Education, First People’s Hospital of Changde City, Changde, China
| | - Joey S W Kwong
- Department of Health Policy, National Center for Child Health and Development, Tokyo, Japan
- Department of Clinical Epidemiology, National Center for Child Health and Development, Tokyo, Japan
| | - Wei Xu
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Mian Tian
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Department of Orthopaedic Surgery, Dianjiang People’s Hospital, Chongqing, China
| | - Yao He
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
- Department of Orthopaedic Surgery, Banan People’s Hospital of Chongqing, Chongqing, China
| | - Wei Huang
- Department of Orthopaedic Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
41
|
Pettersson M, Pettersson J, Johansson A, Molin Thorén M. Titanium release in peri-implantitis. J Oral Rehabil 2018; 46:179-188. [PMID: 30325523 DOI: 10.1111/joor.12735] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Revised: 10/05/2018] [Accepted: 10/10/2018] [Indexed: 12/28/2022]
Abstract
OBJECTIVES The aim of this study was to investigate the titanium (Ti) content of biopsies from patients with severe peri-implantitis or controls without Ti exposure. BACKGROUND Peri-implantitis is considered to be an infectious disease, but recent studies have shown that Ti can aggravate inflammation in combination with bacterial products. The Ti content of peri-implantitis and periodontitis (controls) tissue is unknown. METHODS Thirteen patients referred for peri-implantitis and eleven for periodontitis treatment were included in the study. Disease severity was obtained from dental records. Biopsies were taken from both groups and chemically analysed with inductively coupled plasma mass spectrometry for Ti content. Additionally, two patients with peri-implantitis and two with periodontitis were recruited and their biopsies were analysed microscopically with light microscopy, transmission electron microscopy and scanning electron microscopy with element analysis to investigate the presence of particulate Ti. RESULTS All patients lost one or more implants despite undergoing peri-implant or treatment. Peri-implantitis tissue contained significantly higher concentrations of Ti than control samples with a mean ± SD of 98.7 ± 85.6 and 1.2 ± 0.9 μg/g, respectively. Particulate metal was identified in peri-implantitis and control biopsies, but element analyses could confirm only the presence of Ti in peri-implantitis tissue. CONCLUSION We showed that high contents of particulate and submicron Ti were present in peri-implantitis tissue. These high Ti contents in peri-implant mucosa can potentially aggravate inflammation, which might reduce the prognosis of treatment interventions.
Collapse
Affiliation(s)
- Mattias Pettersson
- Prosthetic Dentistry, Department of Odontology, Faculty of Medicine, Umeå University, Umeå, Sweden
| | - Jean Pettersson
- Department of Chemistry, BMC-Analytic Chemistry, Uppsala University, Uppsala, Sweden
| | - Anders Johansson
- Molecular Periodontology, Department of Odontology, Faculty of Medicine, Umeå University, Umeå, Sweden
| | - Margareta Molin Thorén
- Prosthetic Dentistry, Department of Odontology, Faculty of Medicine, Umeå University, Umeå, Sweden
| |
Collapse
|
42
|
Label-Free Monitoring of Uptake and Toxicity of Endoprosthetic Wear Particles in Human Cell Cultures. Int J Mol Sci 2018; 19:ijms19113486. [PMID: 30404169 PMCID: PMC6274933 DOI: 10.3390/ijms19113486] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Revised: 10/30/2018] [Accepted: 11/02/2018] [Indexed: 12/28/2022] Open
Abstract
The evaluation of the biological effects of endoprosthetic wear particles on cells in vitro relies on a variety of test assays. However, most of these methods are susceptible to particle-induced interferences; therefore, label-free testing approaches emerge as more reliable alternatives. In this study, impedance-based real-time monitoring of cellular viability and metabolic activity were performed following exposure to metallic and ceramic wear particles. Moreover, label-free imaging of particle-exposed cells was done by high-resolution darkfield microscopy (HR-ODM) and field emission scanning electron microscopy (FESEM). The isolated human fibroblasts were exposed to CoCr28Mo6 and alumina matrix composite (AMC) ceramic particles. HR-ODM and FESEM revealed ingested particles. For impedance measurements, cells were seeded on gold-plated microelectrodes. Cellular behavior was monitored over a period of 48 h. CoCr28Mo6 and AMC particle exposure affected cell viability in a concentration-dependent manner, i.e., 0.01 mg/mL particle solutions led to small changes in cell viability, while 0.05 mg/mL resulted in a significant reduction of viability. The effects were more pronounced after exposure to CoCr28Mo6 particles. The results were in line with light and darkfield microcopy observations indicating that the chosen methods are valuable tools to assess cytotoxicity and cellular behavior following exposure to endoprosthetic wear particles.
Collapse
|
43
|
Bu Y, Zheng D, Wang L, Liu J. LncRNA TSIX promotes osteoblast apoptosis in particle-induced osteolysis by down-regulating miR-30a-5p. Connect Tissue Res 2018; 59:534-541. [PMID: 29260905 DOI: 10.1080/03008207.2017.1413362] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE This study aims to investigate the role of TSIX/miR-30a-5p axis in particle-induced osteolysis (PIO). METHOD PIO mouse model was established by the implantation of Co-Cr-Mo metal particles (CoPs). MC3T3-E1 cells received CoPs stimulation. Bone mineral density (BMD) in the skull was detected to evaluate PIO development. The expression of TSIX and miR-30a-5p was detected by using qRT-PCR. Osteoblast apoptosis was measured using flow cytometry. RNA pull-down was used to verify the regulatory relationship between TSIX and miR-30a-5p. RESULT The results showed that BMD of the skull in PIO mice was significantly decreased compared with control mice, which indicated that the PIO model was established successfully. Moreover, CoPs could up-regulate TSIX level, down-regulate miR-30a-5p expression, and promote osteoblast apoptosis in vivo and in vitro. The results also found that TSIX negatively regulated miR-30a-5p expression, and knockdown of TSIX inhibited Runx2 expression. As expected, miR-30a-5p inhibitor could reverse the inhibition of si-TSIX on osteoblast apoptosis. CONCLUSION TSIX played a pivotal role in PIO development by negatively regulating miR-30a-5p.
Collapse
Affiliation(s)
- Yanmin Bu
- a Department of Orthopedics , Tianjin Hospital , Tianjin , People's Republic of China
| | - Dezhi Zheng
- a Department of Orthopedics , Tianjin Hospital , Tianjin , People's Republic of China
| | - Lei Wang
- a Department of Orthopedics , Tianjin Hospital , Tianjin , People's Republic of China
| | - Jun Liu
- a Department of Orthopedics , Tianjin Hospital , Tianjin , People's Republic of China
| |
Collapse
|
44
|
Kurcz B, Lyons J, Sayeed Z, Anoushiravani AA, Iorio R. Osteolysis as it Pertains to Total Hip Arthroplasty. Orthop Clin North Am 2018; 49:419-435. [PMID: 30224004 DOI: 10.1016/j.ocl.2018.06.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Osteolysis is a long-term complication of total hip arthroplasty (THA). As the projected number of THAs performed annually increases, osteolysis will likely continue to occur. However, because of advancements in prosthesis design, metallurgy, and enhanced bearing surfaces, fewer revision THAs will be linked to osteolysis and aseptic loosening. Despite these improvements, no preventative therapies are currently available for the management of osteolysis other than removing and replacing the source of bearing wear.
Collapse
Affiliation(s)
- Brian Kurcz
- Division of Orthopaedic Surgery, Southern Illinois University, 701 North 1st Street, Springfield, IL 62781, USA
| | - Joseph Lyons
- Department of Surgery, Chicago Medical School, 3333 Green Bay Road, North Chicago, IL 60064, USA
| | - Zain Sayeed
- Department of Orthopaedic Surgery, Detroit Medical Center, 4201 Saint Antoine, Detroit, MI 48201, USA
| | - Afshin A Anoushiravani
- Division of Orthopaedic Surgery, Albany Medical Center, 43 New Scotland, Albany, NY, USA
| | - Richard Iorio
- Division of Orthopaedic Surgery, Albany Medical Center, 43 New Scotland, Albany, NY, USA.
| |
Collapse
|
45
|
Cerquiglini A, Henckel J, Hothi HS, Dall'Ava L, Shearing P, Hirschmann MT, Hart AJ. Computed Tomography Techniques Help Understand Wear Patterns in Retrieved Total Knee Arthroplasty. J Arthroplasty 2018; 33:3030-3037. [PMID: 29754982 DOI: 10.1016/j.arth.2018.04.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 03/23/2018] [Accepted: 04/05/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Suboptimal total knee arthroplasty (TKA) position of both femoral and tibial components is thought to be linked with poor clinical outcomes, polyethylene wear and the "unexplained" painful knee arthroplasty. The aim of this study was to better understand the effect of implant orientation on knee implant performance. METHODS We analyzed 30 retrieved contemporary TKA implants. Implant positioning measurements in the coronal plane were made prior to revision using a diagnostic algorithm, based on 3D computed tomography (CT) images. Each retrieved polyethylene component was imaged using a micro-CT scanner and a high resolution computational 3D model of each component was digitally reconstructed. The difference in thickness between medial and lateral components was calculated. Statistical analysis was performed to investigate the association between component positioning and damage patterns. RESULTS We found a significant correlation between both the tibiofemoral and femoral angles and difference in thickness between polyethylene compartments: varus angulations were strongly associated with thinner medial compartments, whilst valgus angulations were associated with thinner lateral compartments. Moreover, suboptimal tibiofemoral orientations and tibial component angulations were associated to greater differences in thickness between polyethylene compartments. CONCLUSION Our study is the first to compare accurate 3D CT measurements of prerevision TKA positioning in the coronal plane with postrevision retrieval analysis from innovative, accurate and highly reliable micro-CT-based method. Our results demonstrate the impact of component positioning on polyethylene damage and helps understanding of the in vivo performance of these implants. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Arianna Cerquiglini
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
| | - Johann Henckel
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
| | - Harry S Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
| | - Lorenzo Dall'Ava
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
| | - Paul Shearing
- Department of Chemical Engineering, Electrochemical Innovation Lab, University College London, London, UK
| | - Michael T Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Bruderholz, Switzerland
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
| |
Collapse
|
46
|
Carbon dots intensified poly (ethylene glycol)/chitosan/sodium glycerophosphate hydrogel as artificial synovium tissue with slow-release lubricant. J Mech Behav Biomed Mater 2018; 88:261-269. [PMID: 30195117 DOI: 10.1016/j.jmbbm.2018.08.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 08/18/2018] [Accepted: 08/19/2018] [Indexed: 12/19/2022]
Abstract
The ultra-high molecular weight polyethylene (UHMWPE) and metal artificial joint pair is limited by wear debris and short service life. Here we report the development of a hydrogel which exhibits lubricant release to intensify the lubrication effect of artificial joints.This study adopted an injectable method to prepare carbon dots/poly (ethylene glycol)/chitosan/sodium glycerophosphate (CDs/PEG/CS/GP) composite hydrogel, and the carbon dots were used to intensify the rheological and mechanical properties. In addition, the composite hydrogel had slow-release properties, and the release solution contained CDs, PEG and GP has excellent lubrication effect. At last, the MTT assay, LIVE/DEAD staining, H&E staining results and safety evaluation in BALC/c mice proved that the hydrogels had good biocompatibilility and were safety for application in vivo.
Collapse
|
47
|
Macrophage Biocompatibility of CoCr Wear Particles Produced under Polarization in Hyaluronic Acid Aqueous Solution. MATERIALS 2018; 11:ma11050756. [PMID: 29738506 PMCID: PMC5978133 DOI: 10.3390/ma11050756] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 04/26/2018] [Accepted: 05/02/2018] [Indexed: 02/06/2023]
Abstract
Macrophages are the main cells involved in inflammatory processes and in the primary response to debris derived from wear of implanted CoCr alloys. The biocompatibility of wear particles from a high carbon CoCr alloy produced under polarization in hyaluronic acid (HA) aqueous solution was evaluated in J774A.1 mouse macrophages cultures. Polarization was applied to mimic the electrical interactions observed in living tissues. Wear tests were performed in a pin-on-disk tribometer integrating an electrochemical cell in phosphate buffer solution (PBS) and in PBS supplemented with 3 g/L HA, an average concentration that is generally found in synovial fluid, used as lubricant solution. Wear particles produced in 3 g/L HA solution showed a higher biocompatibility in J774A.1 macrophages in comparison to those elicited by particles obtained in PBS. A considerable enhancement in macrophages biocompatibility in the presence of 3 g/L of HA was further observed by the application of polarization at potentials having current densities typical of injured tissues suggesting that polarization produces an effect on the surface of the metallic material that leads to the production of wear particles that seem to be macrophage-biocompatible and less cytotoxic. The results showed the convenience of considering the influence of the electric interactions in the chemical composition of debris detached from metallic surfaces under wear corrosion to get a better understanding of the biological effects caused by the wear products.
Collapse
|
48
|
Lu H, Ren S, Li X, Guo J, Dong G, Li J, Gao L. Poly(ethylene glycol)/chitosan/sodium glycerophosphate gel replaced the joint capsule with slow-release lubricant after joint surgery. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2018; 29:1331-1343. [PMID: 29611461 DOI: 10.1080/09205063.2018.1459351] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Body fluid is normally the only lubricant after joint replacement surgery, but wear problems have occurred because body fluid has poor lubrication ability. However, traditional lubricant would be diluted by body fluids and then absorbed by the human body. Therefore, an injectable gel with the ability to slow-release lubricant was designed to replace the joint capsule. The proposed gel, poly(ethylene glycol)/chitosan/sodium glycerophosphate (PEG/CS/GP) composite gel was then tested. The tribology results showed that the PEG/CS/GP gel had excellent slow-release properties, especially under pressure, and the PEG played an important role in improving the gel's rheological and mechanical properties. Moreover, this study revealed that the release solution had a good lubrication effect because the PEG and GP could crosslink via the hydrogen bond effect.
Collapse
Affiliation(s)
- Hailin Lu
- a Key Laboratory for Modern Design & Rotor-Bearing System, Ministry of Education, School of Mechanical Engineering , Xi'an Jiaotong University , Xi'an , P.R. China
| | - Shanshan Ren
- a Key Laboratory for Modern Design & Rotor-Bearing System, Ministry of Education, School of Mechanical Engineering , Xi'an Jiaotong University , Xi'an , P.R. China
| | - Xing Li
- a Key Laboratory for Modern Design & Rotor-Bearing System, Ministry of Education, School of Mechanical Engineering , Xi'an Jiaotong University , Xi'an , P.R. China
| | - Junde Guo
- a Key Laboratory for Modern Design & Rotor-Bearing System, Ministry of Education, School of Mechanical Engineering , Xi'an Jiaotong University , Xi'an , P.R. China
| | - Guangneng Dong
- a Key Laboratory for Modern Design & Rotor-Bearing System, Ministry of Education, School of Mechanical Engineering , Xi'an Jiaotong University , Xi'an , P.R. China
| | - Jianhui Li
- b School of Science , Xi'an Jiaotong University , Xi'an , P.R. China
| | - Li Gao
- c Department of Gynaecology and Obstetrics , The First Affiliated Hospital of Xi'an Jiaotong University, Health Science Center, Xi'an Jiaotong University , Xi'an , P.R. China
| |
Collapse
|
49
|
The remnant preservation technique reduces the amount of bone tunnel enlargement following anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 2018; 26:491-499. [PMID: 28821912 DOI: 10.1007/s00167-017-4679-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2017] [Accepted: 08/16/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE The aim of the present study was to investigate the correlation between postoperative tunnel enlargement after ACLR and remnant tissue preservation using the hamstring tendon. METHODS One hundred and ninety-two subjects (male, n = 101; female, n = 91; mean age 27.1) who had undergone double-bundle ACL reconstruction were included in the present study. The patients were divided into two groups: the remnant tissue preservation group (Group R) and the non-remnant tissue preservation group (Group N). Computed tomographic scans of the operated knee were obtained at 2 weeks and 6 months after surgery. The area of the tunnel aperture for the anteromedial femoral tunnel (FAMT), posterolateral femoral tunnel (FPLT), anteromedial tibial tunnel (TAMT), and posterolateral tibial tunnel (TPLT) was measured. The area at 2 weeks after ACLR was subtracted from the area at 6 months after ACLR and then divided by the area at 2 weeks after ACLR. The differences in the outcomes and characteristics of the two groups were evaluated. RESULTS Seventy-seven knees were classified into Group R, and 115 knees were classified into Group N. The age, gender, and body mass index did not differ to a statistically significant extent. The percentages of FAMT and TAMT enlargement in Group R were significantly smaller in comparison with Group N (P = 0.003 and P = 0.03, respectively). The percentage of FPLT and TPLT enlargement in the two groups did not differ to a statistically significant extent. CONCLUSION The remnant-preserving technique reduces the amount of bone tunnel enlargement. The present findings indicate the advantages of the remnant-preserving ACLR technique, and therefore the remnant-preserving technique should be recommended. LEVEL OF EVIDENCE II.
Collapse
|
50
|
He XB, Ma T, Zheng W, Geng QH, Guo KJ. Nano-sized titanium alloy particles inhibit the proliferation and promote the apoptosis of bone marrow mesenchymal stem cells in vitro. Mol Med Rep 2018; 17:2271-2276. [PMID: 29207046 PMCID: PMC5783474 DOI: 10.3892/mmr.2017.8105] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Accepted: 11/06/2017] [Indexed: 02/05/2023] Open
Abstract
Aseptic loosening of artificial joints is the leading cause of failure for patients who receive total joint arthroplasty. Prior reports indicate that bone marrow mesenchymal stem cells (BSMC) are critical in the stabilization of implanted artificial joints, and that deregulated interaction between BMSCs and artificial joint derived particles is a risk factor for aseptic loosening with an unknown mechanism. In the present study, the pathomechanisms whereby titanium and its alloy derived particles facilitate aseptic loosing were investigated in vitro. It was demonstrated that nano‑sized titanium alloy particles significantly inhibited the proliferation of BMSCs in a time and concentration dependent manner. Furthermore, it was demonstrated that the particles promoted the apoptosis of BMSCs in the same manner. Bax and Caspase‑3 expression of BMSCs were elevated when cultured with the particles. As BMSCs exhibit a critical role in the stabilization of artificial joints, the results of the present study may provide a novel direction for the management of aseptic loosening in clinics.
Collapse
Affiliation(s)
- Xiao-Bo He
- Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Tao Ma
- Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Wei Zheng
- Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Qing-He Geng
- Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| | - Kai-Jin Guo
- Department of Orthopedics, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu 210029, P.R. China
| |
Collapse
|