Şişli E, Yıldırım C, Aka İB, Tuncer ON, Atay Y, Özbaran M, Pekkan K. Switching the Left and the Right Hearts: A Novel Bi-ventricle Mechanical Support Strategy with Spared Native Single-Ventricle. Ann Biomed Eng 2023; 51:2853-2872. [PMID: 37635154 DOI: 10.1007/s10439-023-03348-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 08/09/2023] [Indexed: 08/29/2023]
Abstract
End-stage Fontan patients with single-ventricle (SV) circulation are often bridged-to-heart transplantation via mechanical circulatory support (MCS). Donor shortage and complexity of the SV physiology demand innovative MCS. In this paper, an out-of-the-box circulation concept, in which the left and right ventricles are switched with each other is introduced as a novel bi-ventricle MCS configuration for the "failing" Fontan patients. In the proposed configuration, the systemic circulation is maintained through a conventional mechanical ventricle assist device (VAD) while the venous circulation is delegated to the native SV. This approach spares the SV and puts it to a new use at the right-side providing the most-needed venous flow pulsatility to the failed Fontan circulation. To analyze its feasibility and performance, eight SV failure modes have been studied via an established multi-compartmental lumped parameter cardiovascular model (LPM). Here the LPM model is experimentally validated against the corresponding pulsatile mock-up flow loop measurements of a representative 15-year-old Fontan patient employing a clinically-approved VAD (Medtronic-HeartWare). The proposed surgical configuration maintained the healthy cardiac index (3-3.5 l/min/m2) and the normal mean systemic arterial pressure levels. For a failed SV with low ejection fraction (EF = 26%), representing a typical systemic Fontan failure, the proposed configuration enabled a ~ 28 mmHg amplitude in the venous/pulmonary waveforms and a 2 mmHg decrease in the central venous pressure (CVP) together with acceptable mean pulmonary artery pressures (17.5 mmHg). The pulmonary vascular resistance (PVR)-SV failure case provided a ~ 5 mmHg drop in the CVP, with venous/pulmonary pulsatility reaching to ~ 22 mmHg. For the high PVR failure case with a healthy SV (EF = 44%) pulmonary hypertension is likely to occur as expected. While this condition is routinely encountered during the heart transplantation and managed through pulmonary vasodilators a need for precise functional assessment of the spared failed-ventricle is recommended if utilized in the PVR failure mode. Comprehensive in vitro and in silico results encourage this novel concept as a low-cost, more physiological alternative to the conventional bi-ventricle MCS pending animal experiments.
Collapse
Affiliation(s)
- Emrah Şişli
- Pediatric Cardiovascular Surgery, Department of Cardiovascular Surgery, Osmangazi University Faculty of Medicine, Büyükdere District, Campus of Meşelik, Tepebaşı, 26480, Eskisehir, Turkey.
| | - Canberk Yıldırım
- Department of Biomedical Sciences and Engineering, Koç University, Istanbul, Turkey
| | - İbrahim Başar Aka
- Department of Mechatronics Engineering, İstanbul Bilgi University, Istanbul, Turkey
| | - Osman Nuri Tuncer
- Pediatric Cardiovascular Surgery, Department of Cardiovascular Surgery, Ege University Faculty of Medicine, Izmir, Turkey
| | - Yüksel Atay
- Pediatric Cardiovascular Surgery, Department of Cardiovascular Surgery, Ege University Faculty of Medicine, Izmir, Turkey
| | - Mustafa Özbaran
- Heart Transplantation, Department of Cardiovascular Surgery, Ege University Faculty of Medicine, Izmir, Turkey
| | - Kerem Pekkan
- Department of Mechanical Engineering, Koç University, Rumeli Feneri Campus, Sarıyer, Istanbul, Turkey.
| |
Collapse
|
2
|
A Mechanistic Lumped Parameter Model of the Berlin Heart EXCOR to Analyze Device Performance and Physiologic Interactions. Cardiovasc Eng Technol 2022; 13:603-623. [PMID: 34997556 DOI: 10.1007/s13239-021-00603-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 12/09/2021] [Indexed: 11/02/2022]
Abstract
PURPOSE The Berlin Heart EXCOR (BH) is the only FDA-approved, extracorporeal pulsatile ventricular assist device (VAD) for infants and children with heart failure. Clinicians control four settings on the device-systolic and diastolic drive pressures, device pump rate, and systolic time as a percentage of the pump cycle. However, interactions between BH pneumatics and the native circulation remain poorly understood. Thus, establishing appropriate device size and settings can be challenging on a patient-to-patient basis. METHODS In this study we develop a novel lumped parameter network based on simplified device mechanics. We perform parametric studies to characterize device behavior, study interactions between the left ventricle (LV) and BH across different device settings, and develop patient-specific simulations. We then simulate the impact of changing device parameters for each of three patients. RESULTS Increasing systolic pressure and systolic time increased device output. We identified previously unobserved cycle-to-cycle variations in LV-BH interactions that may impact patient health. Patient-specific simulations demonstrated the model's ability to replicate BH performance, captured trends in LV behavior after device implantation, and emphasized the importance of device rate and volume in optimizing BH efficiency. CONCLUSION We present a novel, mechanistic model that can be readily adjusted to study a wide range of device settings and clinical scenarios. Physiologic interactions between the BH and the native LV produced large variability in cardiac loading. Our findings showed that operating the BH at a device rate greater than the patient's native heart decreases variability in physiological interactions between the BH and LV, increasing cardiac offloading while maintaining cardiac output. Device rates that are close to the resting heart rate may result in unfavorable cardiac loading conditions. Our work demonstrates the utility of our model to investigate BH performance for patient-specific physiologies.
Collapse
|
3
|
OUP accepted manuscript. Eur J Cardiothorac Surg 2022; 62:6570589. [DOI: 10.1093/ejcts/ezac262] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 04/03/2022] [Accepted: 04/14/2022] [Indexed: 11/13/2022] Open
|
4
|
In-Vitro Validation of Self-Powered Fontan Circulation for Treatment of Single Ventricle Anomaly. FLUIDS 2021. [DOI: 10.3390/fluids6110401] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Around 8% of all newborns with a Congenital Heart Defect (CHD) have only a single functioning ventricle. The Fontan operation has served as palliation for this anomaly for decades, but the surgery entails multiple complications, and the survival rate is less than 50% by adulthood. A rapidly testable novel alternative is proposed by creating a bifurcating graft, or Injection Jet Shunt (IJS), used to “entrain” the pulmonary flow and thus provide assistance while reducing the caval pressure. A dynamically scaled Mock Flow Loop (MFL) has been configured to validate this hypothesis. Three IJS nozzles of varying diameters 2, 3, and 4 mm with three aortic anastomosis angles and pulmonary vascular resistance (PVR) reduction have been tested to validate the hypothesis and optimize the caval pressure reduction. The MFL is based on a Lumped-Parameter Model (LPM) of a non-fenestrated Fontan circulation. The best outcome was achieved with the experimental testing of a 3 mm IJS by producing an average caval pressure reduction of more than 5 mmHg while maintaining the clinically acceptable pulmonary flow rate (Qp) to systemic flow rate (Qs) ratio of ~1.5. Furthermore, alteration of the PVR helped in achieving higher caval pressure reduction with the 3 mm IJS at the expense of an increase in Qp/Qs ratio.
Collapse
|
5
|
Engineering Perspective on Cardiovascular Simulations of Fontan Hemodynamics: Where Do We Stand with a Look Towards Clinical Application. Cardiovasc Eng Technol 2021; 12:618-630. [PMID: 34114202 DOI: 10.1007/s13239-021-00541-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 04/30/2021] [Indexed: 01/02/2023]
Abstract
BACKGROUND Cardiovascular simulations for patients with single ventricles undergoing the Fontan procedure can assess patient-specific hemodynamics, explore surgical advances, and develop personalized strategies for surgery and patient care. These simulations have not yet been broadly accepted as a routine clinical tool owing to a number of limitations. Numerous approaches have been explored to seek innovative solutions for improving methodologies and eliminating these limitations. PURPOSE This article first reviews the current state of cardiovascular simulations of Fontan hemodynamics. Then, it will discuss the technical progress of Fontan simulations with the emphasis of its clinical impact, noting that substantial improvements have been made in the considerations of patient-specific anatomy, flow, and blood rheology. The article concludes with insights into potential future directions involving clinical validation, uncertainty quantification, and computational efficiency. The advancements in these aspects could promote the clinical usage of Fontan simulations, facilitating its integration into routine clinical practice.
Collapse
|
6
|
Rosalia L, Ozturk C, Van Story D, Horvath MA, Roche ET. Object‐Oriented Lumped‐Parameter Modeling of the Cardiovascular System for Physiological and Pathophysiological Conditions. ADVANCED THEORY AND SIMULATIONS 2021. [DOI: 10.1002/adts.202000216] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Luca Rosalia
- Institute for Medical Engineering and Science Massachusetts Institute of Technology Cambridge MA 02139 USA
- Harvard‐MIT Program in Health Sciences and Technology Massachusetts Institute of Technology Cambridge MA 02139 USA
| | - Caglar Ozturk
- Institute for Medical Engineering and Science Massachusetts Institute of Technology Cambridge MA 02139 USA
| | - David Van Story
- Institute for Medical Engineering and Science Massachusetts Institute of Technology Cambridge MA 02139 USA
| | - Markus A. Horvath
- Institute for Medical Engineering and Science Massachusetts Institute of Technology Cambridge MA 02139 USA
- Harvard‐MIT Program in Health Sciences and Technology Massachusetts Institute of Technology Cambridge MA 02139 USA
| | - Ellen T. Roche
- Institute for Medical Engineering and Science Massachusetts Institute of Technology Cambridge MA 02139 USA
- Harvard‐MIT Program in Health Sciences and Technology Massachusetts Institute of Technology Cambridge MA 02139 USA
- Department of Mechanical Engineering Massachusetts Institute of Technology Cambridge MA 02139 USA
| |
Collapse
|
7
|
Rubtsova E, Markov A, Selishchev S, Karimov JH, Telyshev D. Mathematical modeling of the Fontan blood circulation supported with pediatric ventricular assist device. Comput Methods Biomech Biomed Engin 2021; 24:653-662. [PMID: 33427490 DOI: 10.1080/10255842.2020.1843640] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
The decompensated univentricular circulation is identified as one of the most challenging conditions and the application of the mechanical circulatory support (MCS) devices is proposed as therapeutic option for Fontan failure. Modelling methodologies are reported to identify the optimized types, extent and duration of required hemodynamic support using MCS. The specific parameters of device-body interaction during support of failing Fontan circulation within the design points of dedicated pediatric ventricular assist devices has not been previously defined. In this work, we introduce a mathematical model developed to simulate the interaction between the Fontan single-ventricular circulation and a constant-flow pediatric ventricular assist device (VAD) Sputnik. The interaction is studied at a pump rotor speed of 5000-9000 rpm. This simulation demonstrates that the pump replacing pulmonary ventricle of the heart creates necessary pressure differential between the systemic veins (7 mmHg) and the pulmonary artery (17.3 mmHg). Moreover, it increases the venous return that, according to the Frank-Starling mechanism, increases the stroke volume up to 32 ml/bpm (26 ml/bpm - without using a pump). For the first time, a simulation for the pediatric VAD Sputnik has been carried out. The simulation results confirm pediatric VAD Sputnik can be a possible tool to normalize the Fontan circulation in pediatric patients.
Collapse
Affiliation(s)
- Ekaterina Rubtsova
- Institute of Biomedical Systems, National Research University of Electronic Technology, Zelenograd, Russian Federation
| | - Aleksandr Markov
- Institute for Bionic Technologies and Engineering, I. M. Sechenov First Moscow State Medical University, Moscow, Russian Federation
| | - Sergey Selishchev
- Institute of Biomedical Systems, National Research University of Electronic Technology, Zelenograd, Russian Federation
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Dmitry Telyshev
- Institute of Biomedical Systems, National Research University of Electronic Technology, Zelenograd, Russian Federation.,Institute for Bionic Technologies and Engineering, I. M. Sechenov First Moscow State Medical University, Moscow, Russian Federation
| |
Collapse
|
8
|
A novel method for hemodynamic analysis of penile erection. Int J Impot Res 2020; 34:55-63. [PMID: 33040088 DOI: 10.1038/s41443-020-00362-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 09/22/2020] [Accepted: 09/24/2020] [Indexed: 11/08/2022]
Abstract
Measurement of blood flow velocity through the cavernosal arteries via penile color Doppler ultrasound (PDUS) is the most common objective method for the assessment of erectile function. However, in some clinical cases, this method needs to be augmented via the invasive intracavernosal pressure (ICP) measurement, which is arguably a more direct index for erectile function. The aim of this study is to develop a lumped parameter model (LPM) of the penile circulation mechanism integrated to a pulsatile, patient-specific, bi-ventricular circulation system to estimate ICP values non-invasively. PDUS data obtained from four random patients with erectile dysfunction are used to develop patient-specific LPMs. Cardiac output is estimated from the body surface area. Systemic pressure is obtained by a sphygmomanometer. Through the appropriate parameter set determined by optimization, patient-specific ICP values are predicted with only using PDUS data and validated by pre- and post-papaverine injection cavernosometry measurements. The developed model predicts the ICP with an average error value of 3 mmHg for both phases. Penile size change during erection is predicted with a ~15% error, according to the clinical size measurements. The developed mathematical model has the potential to be used as an effective non-invasive tool in erectile function evaluation, expanding the existing clinical decision parameters significantly.
Collapse
|
9
|
Kung E, Farahmand M, Gupta A. A Hybrid Experimental-Computational Modeling Framework for Cardiovascular Device Testing. J Biomech Eng 2019; 141:051012. [PMID: 30698632 DOI: 10.1115/1.4042665] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Indexed: 11/08/2022]
Abstract
Significant advances in biomedical science often leverage powerful computational and experimental modeling platforms. We present a framework named physiology simulation coupled experiment ("PSCOPE") that can capitalize on the strengths of both types of platforms in a single hybrid model. PSCOPE uses an iterative method to couple an in vitro mock circuit to a lumped-parameter numerical simulation of physiology, obtaining closed-loop feedback between the two. We first compared the results of Fontan graft obstruction scenarios modeled using both PSCOPE and an established multiscale computational fluid dynamics method; the normalized root-mean-square error values of important physiologic parameters were between 0.1% and 2.1%, confirming the fidelity of the PSCOPE framework. Next, we demonstrate an example application of PSCOPE to model a scenario beyond the current capabilities of multiscale computational methods-the implantation of a Jarvik 2000 blood pump for cavopulmonary support in the single-ventricle circulation; we found that the commercial Jarvik 2000 controller can be modified to produce a suitable rotor speed for augmenting cardiac output by approximately 20% while maintaining blood pressures within safe ranges. The unified modeling framework enables a testing environment which simultaneously operates a medical device and performs computational simulations of the resulting physiology, providing a tool for physically testing medical devices with simulated physiologic feedback.
Collapse
Affiliation(s)
- Ethan Kung
- Department of Mechanical Engineering,Clemson University,Clemson, SC 29634
- Department of Bioengineering,Clemson University,Clemson, SC 29634e-mail:
| | - Masoud Farahmand
- Department of Mechanical Engineering,Clemson University,Clemson, SC 29634e-mail:
| | - Akash Gupta
- Department of Mechanical Engineering,Clemson University,Clemson, SC 29634e-mail:
| |
Collapse
|
10
|
Broda CR, Taylor DA, Adachi I. Progress in experimental and clinical subpulmonary assistance for Fontan circulation. J Thorac Cardiovasc Surg 2018; 156:1949-1956. [PMID: 29884497 DOI: 10.1016/j.jtcvs.2018.04.102] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 04/09/2018] [Accepted: 04/24/2018] [Indexed: 11/15/2022]
Affiliation(s)
- Christopher R Broda
- Department of Pediatric Cardiology, Baylor College of Medicine/Texas Children's Hospital, Houston, Tex.
| | - Doris A Taylor
- Regenerative Medicine Research, Texas Heart Institute, Houston, Tex
| | - Iki Adachi
- Department of Congenital Heart Surgery, Baylor College of Medicine/Texas Children's Hospital, Houston, Tex
| |
Collapse
|
11
|
Pekkan K, Aka IB, Tutsak E, Ermek E, Balim H, Lazoglu I, Turkoz R. In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients. J Thorac Cardiovasc Surg 2018; 156:292-301.e7. [PMID: 29666009 PMCID: PMC6021195 DOI: 10.1016/j.jtcvs.2018.02.088] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 01/11/2018] [Accepted: 02/08/2018] [Indexed: 11/30/2022]
Abstract
Background Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation. Methods Blade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios. Results The prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow. Conclusions Our experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure.
Collapse
Affiliation(s)
- Kerem Pekkan
- Department of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey.
| | - Ibrahim Basar Aka
- Department of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey
| | - Ece Tutsak
- Department of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey
| | - Erhan Ermek
- Department of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey
| | - Haldun Balim
- Department of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey
| | - Ismail Lazoglu
- Department of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey
| | - Riza Turkoz
- Department of Cardiovascular Surgery, School of Medicine, Acıbadem University, Istanbul, Turkey
| |
Collapse
|
12
|
Ni MW, Prather RO, Rodriguez G, Quinn R, Divo E, Fogel M, Kassab AJ, DeCampli WM. Computational Investigation of a Self-Powered Fontan Circulation. Cardiovasc Eng Technol 2018; 9:202-216. [PMID: 29464511 DOI: 10.1007/s13239-018-0342-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 02/12/2018] [Indexed: 11/25/2022]
Abstract
Children born with anatomic or functional "single ventricle" must progress through two or more major operations to sustain life. This management sequence culminates in the total cavopulmonary connection, or "Fontan" operation. A consequence of the "Fontan circulation", however, is elevated central venous pressure and inadequate ventricular preload, which contribute to continued morbidity. We propose a solution to these problems by increasing pulmonary blood flow using an "injection jet" (IJS) in which the source of blood flow and energy is the ventricle itself. The IJS has the unique property of lowering venous pressure while enhancing pulmonary blood flow and ventricular preload. We report preliminary results of an analysis of this circulation using a tightly-coupled, multi-scale computational fluid dynamics model. Our calculations show that, constraining the excess volume load to the ventricle at 50% (pulmonary to systemic flow ratio of 1.5), an optimally configured IJS can lower venous pressure by 3 mmHg while increasing systemic oxygen delivery. Even this small decrease in venous pressure may have substantial clinical impact on the Fontan patient. These findings support the potential for a straightforward surgical modification to decrease venous pressure, and perhaps improve clinical outcome in selected patients.
Collapse
Affiliation(s)
- Marcus W Ni
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL, 32816, USA.
| | - Ray O Prather
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL, 32816, USA
| | - Giovanna Rodriguez
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL, 32816, USA
| | - Rachel Quinn
- College of Medicine, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL, USA
| | - Eduardo Divo
- Department of Mechanical Engineering, Embry-Riddle Aeronautical University, 600 S Clyde Morris Blvd, Daytona Beach, FL, USA
| | - Mark Fogel
- The Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA, USA.,Division of Cardiology/Department of Pediatrics and the Department of Radiology, The Children's Hospital of Philadelphia, 3401 Civic Center Blvd, Philadelphia, PA, USA
| | - Alain J Kassab
- Department of Mechanical and Aerospace Engineering, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL, 32816, USA
| | - William M DeCampli
- College of Medicine, University of Central Florida, 4000 Central Florida Blvd, Orlando, FL, USA.,Arnold Palmer Hospital for Children, 92 W Miller St, Orlando, FL, USA
| |
Collapse
|
13
|
Throckmorton A, Kapadia J, Madduri D. Mechanical axial flow blood pump to support cavopulmonary circulation. Int J Artif Organs 2018; 31:970-82. [DOI: 10.1177/039139880803101107] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We are developing a collapsible, percutaneously inserted, axial flow blood pump to support the cavopulmonary circulation in infants with a failing single ventricle physiology. An initial design of the impeller for this axial flow blood pump was performed using computational fluid dynamics analysis, including pressure-flow characteristics, scalar stress estimations, blood damage indices, and fluid force predictions. A plastic prototype was constructed for hydraulic performance testing, and these experimental results were compared with the numerical predictions. The numerical predictions and experimental findings of the pump performance demonstrated a pressure generation of 2–16 mm Hg for 50–750 ml/min over 5,500–7,500 RPM with deviation found at lower rotational speeds. The axial fluid forces remained below 0.1 N, and the radial fluid forces were determined to be virtually zero due to the centered impeller case. The scalar stress levels remained below 250 Pa for all operating conditions. Blood damage analysis yielded a mean residence time of the released particles, which was found to be less than 0.4 seconds for both flow rates that were examined, and a maximum residence time was determined to be less than 0.8 seconds. We are in the process of designing a cage with hydrodynamically shaped filament blades to act as a diffuser and optimizing the impeller blade shape to reduce the flow vorticity at the pump outlet. This blood pump will improve the clinical treatment of patients with failing Fontan physiology and provide a unique catheter-based therapeutic approach as a bridge to recovery or transplantation.
Collapse
Affiliation(s)
- A.L. Throckmorton
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, Virginia - USA
| | - J. Kapadia
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, Virginia - USA
| | - D. Madduri
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, Virginia - USA
| |
Collapse
|
14
|
Ündar A. The Relative Citation Ratio: Measuring Impact of Publications From an International Conference With a New NIH Metric. Artif Organs 2017; 41:1085-1091. [DOI: 10.1111/aor.13079] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Accepted: 10/16/2017] [Indexed: 01/01/2023]
Affiliation(s)
- Akif Ündar
- Department of Pediatrics - H085. Penn State College of Medicine; Penn State Health Children's Hospital, 500 University Drive; Hershey PA 17033-0850 USA
| |
Collapse
|
15
|
Piskin S, Unal G, Arnaz A, Sarioglu T, Pekkan K. Tetralogy of Fallot Surgical Repair: Shunt Configurations, Ductus Arteriosus and the Circle of Willis. Cardiovasc Eng Technol 2017; 8:107-119. [PMID: 28382440 PMCID: PMC5446850 DOI: 10.1007/s13239-017-0302-5] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Accepted: 03/27/2017] [Indexed: 11/09/2022]
Abstract
In this study, hemodynamic performance of three novel shunt configurations that are considered for the surgical repair of tetralogy of Fallot (TOF) disease are investigated in detail. Clinical experience suggests that the shunt location, connecting angle, and its diameter can influence the post-operative physiology and the neurodevelopment of the neonatal patient. An experimentally validated second order computational fluid dynamics (CFD) solver and a parametric neonatal diseased great artery model that incorporates the ductus arteriosus (DA) and the full patient-specific circle of Willis (CoW) are employed. Standard truncated resistance CFD boundary conditions are compared with the full cerebral arterial system, which resulted 21, -13, and 37% difference in flow rate at the brachiocephalic, left carotid, and subclavian arteries, respectively. Flow splits at the aortic arch and cerebral arteries are calculated and found to change with shunt configuration significantly for TOF disease. The central direct shunt (direct shunt) has pulmonary flow 5% higher than central oblique shunt (oblique shunt) and 23% higher than modified Blalock Taussig shunt (RPA shunt) while the DA is closed. Maximum wall shear stress (WSS) in the direct shunt configuration is 9 and 60% higher than that of the oblique and RPA shunts, respectively. Patent DA, significantly eliminated the pulmonary flow control function of the shunt repair. These results suggests that, due to the higher flow rates at the pulmonary arteries, the direct shunt, rather than the central oblique, or right pulmonary artery shunts could be preferred by the surgeon. This extended model introduced new hemodynamic performance indices for the cerebral circulation that can correlate with the post-operative neurodevelopment quality of the patient.
Collapse
Affiliation(s)
- Senol Piskin
- Department of Mechanical Engineering, Koç University, Rumeli Feneri Kampüsü, Sarıyer, Istanbul, Turkey
| | - Gozde Unal
- Faculty of Engineering and Natural Sciences, Sabancı University, Tuzla, Istanbul, Turkey
| | - Ahmet Arnaz
- Department of Cardiovascular Surgery, Acıbadem Bakırköy Hospital, Istanbul, Turkey
| | - Tayyar Sarioglu
- Department of Pediatric Cardiovascular Surgery, School of Medicine, Acıbadem University, Istanbul, Turkey
| | - Kerem Pekkan
- Department of Mechanical Engineering, Koç University, Rumeli Feneri Kampüsü, Sarıyer, Istanbul, Turkey.
| |
Collapse
|
16
|
A Numerical Simulation Comparing a Cavopulmonary Assist Device and VA ECMO for Failing Fontan Support. ASAIO J 2017; 63:604-612. [PMID: 28319522 DOI: 10.1097/mat.0000000000000560] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
A cavopulmonary assist device (CPAD) has been developed for failing Fontan support. This CPAD pumps blood from superior/inferior vena cavae (SVC/IVC) to pulmonary artery. In this study, we compared failing Fontan support with CPAD versus veno-arterial extracorporeal membrane oxygenation (VA ECMO) in silico. A numerical lumped-parameter circulatory system model was used to simulate Fontan circulation. Failing Fontan was simulated by increased pulmonary resistance. Central venous pressure (CVP), mean pulmonary arterial pressure (mPAP), left atrial pressure (LAP), and univentricular outflow (CO) were simulated and compared with published clinical data. The CPAD and VA ECMO were simulated using 1-5 L/min pump flows. In agreement with published clinical data, the simulated failing Fontan condition had increased CVP (19 mmHg) and mPAP (18 mmHg) with decreased LAP (7 mmHg) and cardiac output (3 L/min) compared with functional Fontan condition. The CPAD achieved total Fontan assistance with pump flows higher than original CO. Veno-arterial extracorporeal membrane oxygenation provided partial Fontan assistance with low pump flows. Blood went through pulmonary circulation with CPAD whereas VA ECMO bypassed pulmonary circulation and diminished univentricular blood flow (0.8 L/min). This in silico study demonstrated that CPAD preserved heart/lung function whereas VA ECMO had very low univentricular flow, potentially leading to thrombosis or univentricular atrophy.
Collapse
|
17
|
Swartz MF, DiVincenti L, Smith K, Westcott R, Belmont K, Harris W, Gensini F, Alfieris GM. A modified LVAD technique to augment caval and pulmonary arterial blood flow in the “failing Fontan” circulation. J Card Surg 2017; 32:126-132. [DOI: 10.1111/jocs.12931] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Michael F. Swartz
- Department of Surgery; University of Rochester Medical Center; Rochester New York
| | - Louis DiVincenti
- Department of Veterinary Medicine; University of Rochester Medical Center; Rochester New York
| | - Karen Smith
- Department of Surgery; University of Rochester Medical Center; Rochester New York
| | - Robin Westcott
- Department of Veterinary Medicine; University of Rochester Medical Center; Rochester New York
| | - Kevin Belmont
- Department of Surgery; University of Rochester Medical Center; Rochester New York
| | - William Harris
- Department of Surgery; University of Rochester Medical Center; Rochester New York
| | - Francisco Gensini
- Department of Surgery; University of Rochester Medical Center; Rochester New York
| | - George M. Alfieris
- Department of Surgery; University of Rochester Medical Center; Rochester New York
| |
Collapse
|
18
|
Di Molfetta A, Ferrari G, Iacobelli R, Filippelli S, Amodeo A. Concurrent use of continuous and pulsatile flow Ventricular Assist Device on a fontan patient: A simulation study. Artif Organs 2016; 41:32-39. [PMID: 28025826 DOI: 10.1111/aor.12859] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 07/07/2016] [Accepted: 08/18/2016] [Indexed: 01/15/2023]
Abstract
The aim of this work is to develop and test a lumped parameter model of the cardiovascular system to simulate the concurrent use of pulsatile (PVAD) and continuous flow (CVAD) ventricular assist device (VAD) on Fontan patients. Echocardiographic and hemodynamic data of five Fontan patients were retrospectively collected and used to simulate the patients' baseline hemodynamics. Then, for each patient, the following assistance modality was simulated for the cavopulmonary and the single ventricle (SV): (a) CVAD for cavopulmonary assistance (RCF) and PVAD assisting the SV (LCF) (RPF + LCF), (b) CVAD assisting SV and PVAD for cavopulmonary assistance (LPF + RCF). The numerical model can well reproduce patients' baseline. The cardiac output increases more importantly in the LCF + RPF configuration (35 vs. 8%). Ventricular volume decreases more evidently in the configuration LCF + RPF (28 vs. 6%), atrial pressure decreases in the LCF + RPF modality (10%), while it slightly increases in the RCF + LPF modality. The pulmonary arterial pressure slightly decreases (increases) in the configuration RCF + LPF (LCF + RPF). Ventricular external work increases in both configurations because of the total increment of the cardiac output. However, artero-ventricular coupling improves in both configurations: RCF + LPF-14%, LCF + RPF-41%. The pulsatility index decreases (increases) by 8% (13.8%) in the configuration LCF + RPF (RCF + LPF). A model could permit us to simulate extreme physiological conditions of the implantation of both CF and PF VAD on the Fontan patient and could permit to choose the proper VAD on the base of patients' condition. The configuration LCF + RPF seems to maximize the hemodynamic benefits.
Collapse
Affiliation(s)
- Arianna Di Molfetta
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù
| | | | - Roberta Iacobelli
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù
| | - Sergio Filippelli
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù
| | - Antonio Amodeo
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù
| |
Collapse
|
19
|
A Mathematical Model of the Cardiovascular System of Pediatric Patients with Congenital Heart Defect. BIOMEDICAL ENGINEERING 2016. [DOI: 10.1007/s10527-016-9626-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
20
|
Good BC, Deutsch S, Manning KB. Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model. Ann Biomed Eng 2016; 44:1019-35. [PMID: 26159560 PMCID: PMC4707135 DOI: 10.1007/s10439-015-1370-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Accepted: 06/16/2015] [Indexed: 10/23/2022]
Abstract
Congenital heart disease is the leading cause of infant death in the United States with over 36,000 newborns affected each year. Despite this growing problem there are few mechanical circulatory support devices designed specifically for pediatric and neonate patients. Previous research has been done investigating pediatric ventricular assist devices (PVADs) assuming blood to be a Newtonian fluid in computational fluid dynamics (CFD) simulations, ignoring its viscoelastic and shear-thinning properties. In contrast to adult VADs, PVADs may be more susceptible to hemolysis and thrombosis due to altered flow into the aorta, and therefore, a more accurate blood model should be used. A CFD solver that incorporates a modified Oldroyd-B model designed specifically for pediatric blood is used to investigate important hemodynamic parameters in a pediatric aortic model under pulsatile flow conditions. These results are compared to Newtonian blood simulations at three physiological pediatric hematocrits. Minor differences are seen in both velocity and wall shear stress (WSS) during early stages of the cardiac cycle between the Newtonian and viscoelastic models. During diastole, significant differences are seen in the velocities in the descending aorta (up to 12%) and in the aortic branches (up to 30%) between the two models. Additionally, peak WSS differences are seen between the models throughout the cardiac cycle. At the onset of diastole, peak WSS differences of 43% are seen between the Newtonian and viscoelastic model and between the 20 and 60% hematocrit viscoelastic models at peak systole of 41%.
Collapse
Affiliation(s)
- Bryan C Good
- Department of Biomedical Engineering, The Pennsylvania State University, 205 Hallowell Building, University Park, PA, 16802, USA
| | - Steven Deutsch
- Department of Biomedical Engineering, The Pennsylvania State University, 205 Hallowell Building, University Park, PA, 16802, USA
| | - Keefe B Manning
- Department of Biomedical Engineering, The Pennsylvania State University, 205 Hallowell Building, University Park, PA, 16802, USA.
- Department of Surgery, Penn State Hershey Medical Center, Hershey, PA, 17033, USA.
| |
Collapse
|
21
|
Good BC, Deutsch S, Manning KB. Continuous and Pulsatile Pediatric Ventricular Assist Device Hemodynamics with a Viscoelastic Blood Model. Cardiovasc Eng Technol 2016; 7:23-43. [PMID: 26643646 PMCID: PMC4767652 DOI: 10.1007/s13239-015-0252-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2015] [Accepted: 11/23/2015] [Indexed: 11/25/2022]
Abstract
To investigate the effects of pulsatile and continuous pediatric ventricular assist (PVAD) flow and pediatric blood viscoelasticity on hemodynamics in a pediatric aortic graft model. Hemodynamic parameters of pulsatility, along with velocity and wall shear stress (WSS), are analyzed and compared between Newtonian and viscoelastic blood models at a range of physiological pediatric hematocrits using computational fluid dynamics. Both pulsatile and continuous PVAD flow lead to a decrease in pulsatility (surplus hemodynamic energy, ergs/cm(3)) compared to healthy aortic flow but with continuous PVAD pulsatility up to 2.4 times lower than pulsatile PVAD pulsatility at each aortic outlet. Significant differences are also seen between the two flow modes in velocity and WSS. The higher velocity jet during systole with pulsatile flow leads to higher WSSs at the anastomotic toe and at the aortic branch bifurcations. The lower velocity but continuous flow jet leads to a much different flow field and higher WSSs into diastole. Under a range of physiological pediatric hematocrit (20-60%), both velocity and WSS can vary significantly with the higher hematocrit blood model generally leading to higher peak WSSs but also lower WSSs in regions of flow separation. The large decrease in pulsatility seen from continuous PVAD flow could lead to complications in pediatric vascular development while the high WSSs during peak systole from pulsatile PVAD flow could lead to blood damage. Both flow modes lead to similar regions prone to intimal hyperplasia resulting from low time-averaged WSS and high oscillatory shear index.
Collapse
Affiliation(s)
- Bryan C Good
- Department of Biomedical Engineering, The Pennsylvania State University, 205 Hallowell Building, University Park, PA, 16802, USA
| | - Steven Deutsch
- Department of Biomedical Engineering, The Pennsylvania State University, 205 Hallowell Building, University Park, PA, 16802, USA
| | - Keefe B Manning
- Department of Biomedical Engineering, The Pennsylvania State University, 205 Hallowell Building, University Park, PA, 16802, USA.
- Department of Surgery, Penn State Hershey Medical Center, Hershey, PA, 17033, USA.
| |
Collapse
|
22
|
Di Molfetta A, Amodeo A, Fresiello L, Filippelli S, Pilati M, Iacobelli R, Adorisio R, Colella D, Ferrari G. The use of a numerical model to simulate the cavo-pulmonary assistance in Fontan circulation: a preliminary verification. J Artif Organs 2015; 19:105-13. [PMID: 26545595 DOI: 10.1007/s10047-015-0874-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Accepted: 10/26/2015] [Indexed: 12/30/2022]
Abstract
The lack of an established experience on the use of VAD for the cavo-pulmonary assistance leads to the need of dedicated VADs development and animal experiments. A dedicated numerical model could support clinical and experimental strategies design and new VADs testing. The aim of this work is to perform a preliminary verification of a lumped parameter model of the cardiovascular system to simulate Fontan physiology and the effect of cavo-pulmonary assistance. Literature data of 4 pigs were used to simulate animals' baseline, and then the model was tested in simulating Fontan circulation and cavo-pulmonary-assisted condition comparing the simulation outcome (Sim) with measured literature data (Me). The results show that the numerical model can well reproduce experimental data in all three conditions (baseline, Fontan and assisted Fontan) [cardiac output (l/min): Me = 2.8 ± 1.7, Sim = 2.8 ± 1.8; ejection fraction (%): Me = 57 ± 17, Sim = 54 ± 17; arterial systemic pressure (mmHg): Me = 41.8 ± 18.6, Sim = 43.8 ± 18.1; pulmonary arterial pressure (mmHg): Me = 15.4 ± 8.9, Sim = 17.7 ± 9.9; caval pressure (mmHg): Me = 6.8 ± 4.1, Sim = 7 ± 4.6]. Systolic elastance, arterial systemic and arterial pulmonary resistances increase (10, 69, and 100 %) passing from the biventricular circulation to the Fontan physiology and then decrease (21, 39, and 50 %) once the VAD was implanted. The ventricular external work decreases (71 %) passing from the biventricular circulation to the Fontan physiology and it increases three times after the VAD implantation in parallel with the VAD power consumption. A numerical model could support clinicians in an innovative and challenging field as the use of VAD to assist the Fontan physiology and it could be helpful to personalize the VAD insertion on the base of ventricular systo-diastolic function, circulatory parameters and energetic variables.
Collapse
Affiliation(s)
- Arianna Di Molfetta
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Via San Martino della Battaglia, 44, 00185, Rome, Italy.
| | - Antonio Amodeo
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Via San Martino della Battaglia, 44, 00185, Rome, Italy
| | | | - Sergio Filippelli
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Via San Martino della Battaglia, 44, 00185, Rome, Italy
| | - Mara Pilati
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Via San Martino della Battaglia, 44, 00185, Rome, Italy
| | - Roberta Iacobelli
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Via San Martino della Battaglia, 44, 00185, Rome, Italy
| | - Rachele Adorisio
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Via San Martino della Battaglia, 44, 00185, Rome, Italy
| | - Dionisio Colella
- Cardiac Surgery Intensive Care Unit, University of Tor Vergata, Rome, Italy
| | | |
Collapse
|
23
|
Control of respiration-driven retrograde flow in the subdiaphragmatic venous return of the Fontan circulation. ASAIO J 2015; 60:391-9. [PMID: 24814833 DOI: 10.1097/mat.0000000000000093] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Respiration influences the subdiaphragmatic venous return in the total cavopulmonary connection (TCPC) of the Fontan circulation whereby both the inferior vena cava (IVC) and hepatic vein flows can experience retrograde motion. Controlling retrograde flows could improve patient outcomes. Using a patient-specific model within a Fontan mock circulatory system with respiration, we inserted a valve into the IVC to examine its effects on local hemodynamics while varying retrograde volumes by changing vascular impedances. A bovine valved conduit reduced IVC retrograde flow to within 3% of antegrade flow in all cases. The valve closed only under conditions supporting retrograde flow and its effects on local hemodynamics increased with larger retrograde volume. Liver and TCPC pressures improved only when the valve leaflets were closed whereas cycle-averaged pressures improved only slightly (<1 mm Hg). Increased pulmonary vascular resistance raised mean circulation pressures, but the valve functioned and cardiac output improved and stabilized. Power loss across the TCPC improved by 12%-15% (p < 0.05) with a valve. The effectiveness of valve therapy is dependent on patient vascular impedance.
Collapse
|
24
|
Di Molfetta A, Amodeo A, Gagliardi MG, Trivella MG, Fresiello L, Filippelli S, Toscano A, Ferrari G. Hemodynamic Effects of Ventricular Assist Device Implantation on Norwood, Glenn, and Fontan Circulation: A Simulation Study. Artif Organs 2015; 40:34-42. [PMID: 26526959 DOI: 10.1111/aor.12591] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The growing population of failing single-ventricle (SV) patients might benefit from ventricular assist device (VAD) support as a bridge to heart transplantation. However, the documented experience is limited to isolated case reports. Considering the complex and different physiopathology of Norwood, Glenn, and Fontan patients and the lack of established experience, the aim of this work is to realize and test a lumped parameter model of the cardiovascular system able to simulate SV hemodynamics and VAD implantation effects to support clinical decision. Hemodynamic and echocardiographic data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output and the mean arterial systemic pressure in all the three palliation conditions (Norwood 77.2 and 19.7%, Glenn 38.6 and 32.2%, and Fontan 17.2 and 14.2%); (ii) decreases the SV external work (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) decreases the pressure pulsatility index (Norwood 65.2%, Glenn 81.3%, and Fontan 64.8%); (iv) increases the pulmonary arterial pressure in particular in the Norwood circulation (Norwood 39.7%, Glenn 12.1% and Fontan 3%); and (v) decreases the atrial pressure (Norwood 2%, Glenn 10.6%, and Fontan 8.6%). Finally, the VAD work is lower in the Norwood circulation (30.4 mL·mm Hg) in comparison with Fontan (40.3 mL·mm Hg) and to Glenn (64.5 mL·mm Hg) circulations. The use of VAD in SV physiology could be helpful to bridge patients to heart transplantations by increasing the CO and unloading the SV with a decrement of the atrial pressure and the SV external work. The regulation of the pulmonary flow is challenging because the Pap is increased by the presence of VAD. The hemodynamic changes are different in the different SV palliation step. The use of numerical models could be helpful to support patient and VAD selection to optimize the clinical outcome.
Collapse
Affiliation(s)
- Arianna Di Molfetta
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Antonio Amodeo
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Maria G Gagliardi
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Maria G Trivella
- Cardiovascular Engineering Laboratory-Institute of Clinical Physiology, CNR, Rome, Italy
| | - Libera Fresiello
- Clinical Cardiac Surgery Department, Catholic University of Leuven, Leuven, Belgium
| | - Sergio Filippelli
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Alessandra Toscano
- Department of Pediatric Cardiology and Cardiosurgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Gianfranco Ferrari
- Cardiovascular Engineering Laboratory-Institute of Clinical Physiology, CNR, Rome, Italy
| |
Collapse
|
25
|
Di Molfetta A, Ferrari G, Filippelli S, Fresiello L, Iacobelli R, Gagliardi MG, Amodeo A. Use of Ventricular Assist Device in Univentricular Physiology: The Role of Lumped Parameter Models. Artif Organs 2015; 40:444-53. [PMID: 26494529 DOI: 10.1111/aor.12583] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Failing single-ventricle (SV) patients might benefit from ventricular assist devices (VADs) as a bridge to heart transplantation. Considering the complex physiopathology of SV patients and the lack of established experience, the aim of this work was to realize and test a lumped parameter model of the cardiovascular system, able to simulate SV hemodynamics and VAD implantation effects. Data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Additionally, both the effects of ventricular assistance and cavopulmonary assistance were simulated in different pathologic conditions on Fontan patients, including systolic dysfunction, diastolic dysfunction, and pulmonary vascular resistance increment. The model can reproduce patients' baseline well. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output (CO) in all the three palliation conditions (Norwood 77.2%, Glenn 38.6%, and Fontan 17.2%); (ii) decreases the SV external work (SVEW) (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) increases the mean pulmonary arterial pressure (Pap) (Norwood 39.7%, Glenn 12.1%, and Fontan 3%). In Fontan circulation, with systolic dysfunction, the left VAD (LVAD) increases CO (35%), while the right VAD (RVAD) determines a decrement of inferior vena cava pressure (Pvci) (39%) with 34% increment of CO. With diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci. With pulmonary vascular resistance increment, the RVAD allows the highest CO (50%) increment with the highest decrement of Pvci (53%). The single ventricular external work (SVEW) increases (decreases) increasing the VAD speed in cavopulmonary (ventricular) assistance. Numeric models could be helpful in this challenging and innovative field to support patients and VAD selection to optimize the clinical outcome and personalize the therapy.
Collapse
Affiliation(s)
- Arianna Di Molfetta
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | | | - Sergio Filippelli
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Libera Fresiello
- Section of Rome, CNR, Institute of Clinical Physiology, Rome, Italy
| | - Roberta Iacobelli
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Maria G Gagliardi
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Antonio Amodeo
- Department of Pediatric Cardiology and Cardiac Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| |
Collapse
|
26
|
Vallecilla C, Khiabani RH, Trusty P, Sandoval N, Fogel M, Briceño JC, Yoganathan AP. Exercise capacity in the Bidirectional Glenn physiology: Coupling cardiac index, ventricular function and oxygen extraction ratio. J Biomech 2015; 48:1997-2004. [PMID: 25913242 PMCID: PMC4492809 DOI: 10.1016/j.jbiomech.2015.03.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Revised: 03/18/2015] [Accepted: 03/27/2015] [Indexed: 11/25/2022]
Abstract
In Bi-directional Glenn (BDG) physiology, the superior systemic circulation and pulmonary circulation are in series. Consequently, only blood from the superior vena cava is oxygenated in the lungs. Oxygenated blood then travels to the ventricle where it is mixed with blood returning from the lower body. Therefore, incremental changes in oxygen extraction ratio (OER) could compromise exercise tolerance. In this study, the effect of exercise on the hemodynamic and ventricular performance of BDG physiology was investigated using clinical patient data as inputs for a lumped parameter model coupled with oxygenation equations. Changes in cardiac index, Qp/Qs, systemic pressure, oxygen extraction ratio and ventricular/vascular coupling ratio were calculated for three different exercise levels. The patient cohort (n=29) was sub-grouped by age and pulmonary vascular resistance (PVR) at rest. It was observed that the changes in exercise tolerance are significant in both comparisons, but most significant when sub-grouped by PVR at rest. Results showed that patients over 2 years old with high PVR are above or close to the upper tolerable limit of OER (0.32) at baseline. Patients with high PVR at rest had very poor exercise tolerance while patients with low PVR at rest could tolerate low exercise conditions. In general, ventricular function of SV patients is too poor to increase CI and fulfill exercise requirements. The presented mathematical model provides a framework to estimate the hemodynamic performance of BDG patients at different exercise levels according to patient specific data.
Collapse
Affiliation(s)
| | - Reza H Khiabani
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Phillip Trusty
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Néstor Sandoval
- Department of Cardiovascular Surgery, Fundación Cardioinfantil, Bogotá, Colombia
| | - Mark Fogel
- Division of Cardiology, Children׳s Hospital of Philadelphia, Philadelphia, PA, USA
| | - Juan Carlos Briceño
- Group of Biomedical Engineering, Universidad de los Andes, Bogotá, Colombia; Research Department, Fundación Cardioinfantil, Bogotá, Colombia
| | - Ajit P Yoganathan
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.
| |
Collapse
|
27
|
Di Molfetta A, Amodeo A, Fresiello L, Trivella MG, Iacobelli R, Pilati M, Ferrari G. Simulation of Ventricular, Cavo-Pulmonary, and Biventricular Ventricular Assist Devices in Failing Fontan. Artif Organs 2015; 39:550-8. [PMID: 25808201 DOI: 10.1111/aor.12434] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Considering the lack of donors, ventricular assist devices (VADs) could be an alternative to heart transplantation for failing Fontan patients, in spite of the lack of experience and the complex anatomy and physiopathology of these patients. Considering the high number of variables that play an important role such as type of Fontan failure, type of VAD connection, and setting (right VAD [RVAD], left VAD [LVAD], or biventricular VAD [BIVAD]), a numerical model could be useful to support clinical decisions. The aim of this article is to develop and test a lumped parameter model of the cardiovascular system simulating and comparing the VAD effects on failing Fontan. Hemodynamic and echocardiographic data of 10 Fontan patients were used to simulate the baseline patients' condition using a dedicated lumped parameter model. Starting from the simulated baseline and for each patient, a systolic dysfunction, a diastolic dysfunction, and an increment of the pulmonary vascular resistance were simulated. Then, for each patient and for each pathology, the RVAD, LVAD, and BIVAD implantations were simulated. The model can reproduce patients' baseline well. In the case of systolic dysfunction, the LVAD unloads the single ventricle and increases the cardiac output (CO) (35%) and the arterial systemic pressure (Pas) (25%). With RVAD, a decrement of inferior vena cava pressure (Pvci) (39%) was observed with 34% increment of CO, but an increment of the single ventricle external work (SVEW). With the BIVAD, an increment of Pas (29%) and CO (37%) was observed. In the case of diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci, while both increase the SVEW. In the case of pulmonary vascular resistance increment, the highest CO (50%) and Pas (28%) increment is obtained with an RVAD with the highest decrement of Pvci (53%) and an increment of the SVEW but with the lowest VAD power consumption. The use of numerical models could be helpful in this innovative field to evaluate the effect of VAD implantation on Fontan patients to support patient and VAD type selection personalizing the assistance.
Collapse
Affiliation(s)
- Arianna Di Molfetta
- Cardiovascular Engineering Laboratory, Institute of Clinical Physiology-CNR, Rome, Italy
| | - Antonio Amodeo
- Department of Pediatric Cardiology and Cardio Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Libera Fresiello
- Cardiovascular Engineering Laboratory, Institute of Clinical Physiology-CNR, Rome, Italy
| | | | - Roberta Iacobelli
- Department of Pediatric Cardiology and Cardio Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Mara Pilati
- Department of Pediatric Cardiology and Cardio Surgery, Pediatric Hospital Bambino Gesù, Rome, Italy
| | - Gianfranco Ferrari
- Cardiovascular Engineering Laboratory, Institute of Clinical Physiology-CNR, Rome, Italy
| |
Collapse
|
28
|
Yigit MB, Kowalski WJ, Hutchon DJR, Pekkan K. Transition from fetal to neonatal circulation: Modeling the effect of umbilical cord clamping. J Biomech 2015; 48:1662-70. [PMID: 25773588 DOI: 10.1016/j.jbiomech.2015.02.040] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2015] [Accepted: 02/17/2015] [Indexed: 11/17/2022]
Abstract
Hemodynamics of the fetal to neonatal transition are orchestrated through complex physiological changes and results in cardiovascular adaptation to the adult biventricular circulation. Clinical practice during this critical period can influence vital organ physiology for normal newborns, premature babies and congenital heart defect patients. Particularly, the timing of the cord clamping procedure, immediate (ICC) vs. delayed cord clamping (DCC), is hypothesized to be an important factor for the transitory fetal hemodynamics. The clinical need for a quantitative understanding of this physiology motivated the development of a lumped parameter model (LPM) of the fetal cardio-respiratory system covering the late-gestation to neonatal period. The LPM was validated with in vivo clinical data and then used to predict the effects of cord clamping procedures on hemodynamics and vital gases. Clinical time-dependent resistance functions to simulate the vascular changes were introduced. For DCC, placental transfusion (31.3 ml) increased neonatal blood volume by 11.7%. This increased blood volume is reflected in an increase in preload pressures by ~20% compared to ICC, which in turn increased the cardiac output (CO) by 20% (COICC=993 ml/min; CODCC=1197 ml/min). Our model accurately predicted dynamic flow patterns in vivo. DCC was shown to maintain oxygenation if the onset of pulmonary respiration was delayed or impaired. On the other hand, a significant 25% decrease in oxygen saturations was observed when applying ICC under the same physiological conditions. We conclude that DCC has a significant impact on newborn hemodynamics, mainly because of the improved blood volume and the sustained placental respiration.
Collapse
Affiliation(s)
- Mehmet B Yigit
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - William J Kowalski
- Cardiovascular Innovation Institute, University of Louisville, Louisville, KY, USA
| | | | - Kerem Pekkan
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA; Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sariyer, Istanbul, Turkey.
| |
Collapse
|
29
|
Vallecilla C, Khiabani RH, Sandoval N, Fogel M, Briceño JC, Yoganathan AP. Effect of high altitude exposure on the hemodynamics of the bidirectional Glenn physiology: modeling incremented pulmonary vascular resistance and heart rate. J Biomech 2014; 47:1846-52. [PMID: 24755120 DOI: 10.1016/j.jbiomech.2014.03.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Revised: 01/22/2014] [Accepted: 03/11/2014] [Indexed: 10/25/2022]
Abstract
The considerable blood mixing in the bidirectional Glenn (BDG) physiology further limits the capacity of the single working ventricle to pump enough oxygenated blood to the circulatory system. This condition is exacerbated under severe conditions such as physical activity or high altitude. In this study, the effect of high altitude exposure on hemodynamics and ventricular function of the BDG physiology is investigated. For this purpose, a mathematical approach based on a lumped parameter model was developed to model the BDG circulation. Catheterization data from 39 BDG patients at stabilized oxygen conditions was used to determine baseline flows and pressures for the model. The effect of high altitude exposure was modeled by increasing the pulmonary vascular resistance (PVR) and heart rate (HR) in increments up to 80% and 40%, respectively. The resulting differences in vascular flows, pressures and ventricular function parameters were analyzed. By simultaneously increasing PVR and HR, significant changes (p <0.05) were observed in cardiac index (11% increase at an 80% PVR and 40% HR increase) and pulmonary flow (26% decrease at an 80% PVR and 40% HR increase). Significant increase in mean systemic pressure (9%) was observed at 80% PVR (40% HR) increase. The results show that the poor ventricular function fails to overcome the increased preload and implied low oxygenation in BDG patients at higher altitudes, especially for those with high baseline PVRs. The presented mathematical model provides a framework to estimate the hemodynamic performance of BDG patients at different PVR increments.
Collapse
Affiliation(s)
| | - Reza H Khiabani
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 Ferst Dr., Atlanta, GA 30332, USA
| | - Néstor Sandoval
- Department of Cardiovascular Surgery, Fundación Cardioinfantil, Bogotá, Colombia
| | - Mark Fogel
- Division of Cardiology, Children׳s Hospital of Philadelphia, Philadelphia, PA, USA
| | - Juan Carlos Briceño
- Group of Biomedical Engineering, Universidad de los Andes, Bogotá, Colombia; Research Department, Fundación Cardioinfantil, Bogotá, Colombia
| | - Ajit P Yoganathan
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 Ferst Dr., Atlanta, GA 30332, USA.
| |
Collapse
|
30
|
Rinaudo A, D'Ancona G, Baglini R, Amaducci A, Follis F, Pilato M, Pasta S. Computational fluid dynamics simulation to evaluate aortic coarctation gradient with contrast-enhanced CT. Comput Methods Biomech Biomed Engin 2014; 18:1066-1071. [PMID: 24460213 DOI: 10.1080/10255842.2013.869321] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Coarctation of aorta (CoA) is a narrowing of the aorta leading to a pressure gradient (ΔP) across the coarctation, increased afterload and reduced peripheral perfusion pressures. Indication to invasive treatment is based on values of maximal (systolic) trans-coarctation ΔP. A computational fluid dynamic (CFD) approach is herein presented for the non-invasive haemodynamic assessment of ΔP across CoA. Patient-specific CFD simulations were created from contrast-enhanced computed tomography (CT) and appropriate flow boundary conditions. Computed ΔP was validated with invasive intravascular trans-CoA pressure measurements. Haemodynamic indices, including pressure loss coefficient (PLc), time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI), were also quantified. CFD-estimated ΔP values were comparable to the invasive ones. Moreover, the aorta proximal to CoA was exposed to altered TAWSS and OSI suggesting hypertension. PLc was found as a further geometric marker of CoA severity. Finally, CFD-estimated ΔP confirmed a significant reduction after percutaneous balloon dilatation and stenting of the CoA in one patient (e.g. from ΔP∼52 mmHg to ΔP∼3 mmHg). The validation of the ΔP computations with catheterisation measurements suggests that CFD simulation, based on CT-derived anatomical data, is a useful tool to readily quantify CoA severity.
Collapse
Affiliation(s)
- Antonino Rinaudo
- a Dipartimento di Ingegneria Chimica , Gestionale, Informatica e Meccanica, Universita' di Palermo , Viale delle Scienze Ed. 8, 90128 Palermo , Italy
| | | | | | | | | | | | | |
Collapse
|
31
|
Albal PG, Menon PG, Kowalski W, Undar A, Turkoz R, Pekkan K. Novel fenestration designs for controlled venous flow shunting in failing Fontans with systemic venous hypertension. Artif Organs 2013; 37:66-75. [PMID: 23305575 DOI: 10.1111/aor.12011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The Fontan procedure is employed as the final-stage palliation in single-ventricle congenital heart patients and results in diversion of venous blood directly to the pulmonary arteries. Fontan patients have been known to suffer from postoperative systemic venous hypertension, which in turn is associated with pleural effusions and protein losing enteropathy, leading to a decreased duration and quality of life. Despite the ongoing debate on its benefits, a circular fenestration hole (typically 4 mm) establishing a venous shunt to the common atrium is traditionally employed to relieve venous pressure in the Fontan conduit and improve early postoperative Fontan hemodynamics. However, these improvements come at the cost of reduced oxygen saturation due to excessive right-to-left shunting if the fenestration is permanent. The ideal "selective" fenestration would therefore limit or eliminate shunt flow at tolerable systemic venous pressures and allow increased flow at high pressures. The objective of this study is to introduce new fenestration designs that exhibit these desirable pressure-flow characteristics. Novel plus-shaped and S-shaped fenestration designs with leaflets are introduced as alternatives to the traditional circular fenestration, each having identical effective orifice areas at the fully open states. In vitro steady leakage flow tests were performed for physiological flow-driving pressures in order to obtain pressure-drop versus flow-rate characteristics. In addition, the leaflet opening kinematics of the plus-shaped fenestration was investigated computationally using finite element simulation. Fluid-structure interaction analysis was performed to determine leaflet displacements and pressure-flow characteristics at low pressures. Further, a lumped parameter model of the single-ventricle circuit was created to simulate pulsatile flow conditions For the plus-shaped fenestration, the flow rate was found to increase nonlinearly with increased driving systemic venous pressures at high physiological-pressure drops which did not cause the leaflets to fully open, and linearly for low driving pressures. These results indicate that leaflets of the plus-shaped fenestration design activated passively after a critical systemic venous pressure threshold. This feature is ideal for minimizing undesirable excessive venous shunting. A large variability in shunting flow rate may be obtained by changing the shape, thickness, size, and material of the fenestration to suit requirements of the patient, which can further limit shunt flow in a controlled manner.
Collapse
Affiliation(s)
- Priti G Albal
- Biomedical Engineering Department, Carnegie Mellon University, Pittsburgh, PA, USA
| | | | | | | | | | | |
Collapse
|
32
|
Durham LA, Dearani JA, Burkhart HM, Joyce LD, Cetta F, Cabalka AK, Phillips SD, Sundareswaran K, Farrar D, Park SJ. Application of Computer Modeling in Systemic VAD Support of Failing Fontan Physiology. World J Pediatr Congenit Heart Surg 2013; 2:243-8. [PMID: 23804979 DOI: 10.1177/2150135110397386] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Although the Fontan procedure has been enormously successful in palliation of single-ventricle patients, many seem to experience progressive failure of the Fontan circulation over time. Ventricular assist devices (VADs) have developed into stable platforms for long-term support of adult patients with heart failure. Given the success of axial flow devices, it was hypothesized that the technology could provide clinical benefit to failing Fontan patients. The aim of this study was to use a computer model to evaluate VAD support in failing Fontan physiology. A computer model of Fontan circulation with heart failure was developed and the HeartMate II (HM II) (Thoratec Corp) axial flow ventricular assist device was connected to this model in a systemic configuration to examine its impact. Cardiac catheterization data from 7 patients (8 catheterization studies) with failing Fontan physiology were applied to this model to evaluate the impact of using the HM II in this manner. When the HM II was used in a systemic configuration at 8000 rpm, there was a 35% decrease in the systemic venous pressure in the Fontan circuit and a 63% decrease in pulmonary capillary wedge pressure with a resultant 41% increase in CI. The model also predicted patient-specific parameters where the VAD may not benefit the patient, such as fixed elevated pulmonary vascular resistance, low systemic ventricular end-diastolic pressure, and high unresponsive systemic vascular resistance. These data suggest a potential benefit from application of axial flow VAD technology in the management of failing Fontan physiology. Clinical correlation will allow for refinement of this model as a predictive tool in discerning which patients may benefit from placement of a VAD and what issues must be addressed prior to implanting the device.
Collapse
Affiliation(s)
- Lucian A Durham
- Division of Cardiovascular Surgery, The Mayo Clinic, Rochester, MN, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
|
34
|
Mirabella L, Haggerty CM, Passerini T, Piccinelli M, Powell AJ, Del Nido PJ, Veneziani A, Yoganathan AP. Treatment planning for a TCPC test case: a numerical investigation under rigid and moving wall assumptions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2013; 29:197-216. [PMID: 23345252 DOI: 10.1002/cnm.2517] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Revised: 08/17/2012] [Indexed: 05/29/2023]
Abstract
The hemodynamics in patients with total cavopulmonary connections (TCPC) is generally very complex and characterized by patient-to-patient variability. To better understand its effect on patients' outcome, CFD models are widely used, also to test and optimize surgical options before their implementation. These models often assume rigid geometries, despite the motion experienced by thoracic vessels that could influence the hemodynamics predictions. By improving their accuracy and expanding the range of simulated interventions, the benefit of treatment planning for patients is expected to increase. We simulate three types of intervention on a patient-specific 3D model, and compare their predicted outcome with baseline condition: a decrease in pulmonary vascular resistance obtainable with medications; a surgical revision of the connection design; the introduction of a fenestration in the TCPC wall. The simulations are performed both with rigid wall assumption and including patient-specific TCPC wall motion, reconstructed from a 4DMRI dataset. The results show the effect of each option on clinically important metrics and highlight the impact of patient-specific wall motion. The largest differences between rigid and moving wall models are observed in measures of energetic efficiency of TCPC as well as in hepatic flow distribution and transit time of seeded particles through the connection.
Collapse
Affiliation(s)
- Lucia Mirabella
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA, USA
| | | | | | | | | | | | | | | |
Collapse
|
35
|
Menon PG, Yoshida M, Pekkan K. Presurgical evaluation of Fontan connection options for patients with apicocaval juxtaposition using computational fluid dynamics. Artif Organs 2012; 37:E1-8. [PMID: 23145982 DOI: 10.1111/j.1525-1594.2012.01555.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Apicocaval juxtaposition (ACJ) is a rare congenital heart defect associated with single ventricle physiology where optimal positioning of the Fontan conduit for completion of total cavopulmonary connection (TCPC) is still controversial. In ACJ, the cardiac apex is ipsilateral with the inferior vena cava (IVC), risking kinking and collapse of the Fontan conduit at the apex of the heart. The purpose of this study is to evaluate two viable routes for Fontan conduit connection in patients with ACJ, using computational fluid dynamics. Internal energy loss evaluations were used to determine contribution of conduit curvature to the energy efficiency of each cavopulmonary anastomosis configuration. This percentage of energy loss contribution was found to be greater in the case of a curved extracardiac conduit connection (44%, 4.1 mW) traveling behind the ventricular apex, connecting the IVC to the left pulmonary artery, than the straighter lateral tunnel conduit (6%, 1.4 mW) installed through the ventricular apex. In contrast, net energy loss across the anastomosis was significantly lower with extracardiac TCPC (9.3 mW) in comparison with lateral tunnel TCPC (23.2 mW), highlighting that a curved Fontan conduit is favorable provided that it is traded off for a superior cavopulmonary connection efficiency. Therefore, a relatively longer and curved Fontan conduit has been demonstrated to be a suitable connection option independent of anatomical situations.
Collapse
Affiliation(s)
- Prahlad G Menon
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | | | | |
Collapse
|
36
|
Pincott ES, Burch M. Mechanical bridging to orthotopic heart transplantation in children. Future Cardiol 2012; 8:753-63. [PMID: 23013126 DOI: 10.2217/fca.12.56] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
This article discusses the main methods currently used in clinical practice to support patients with end-stage heart failure and the research into new devices under development, particularly for young children. With an increasing demand on the supply of organs available for heart transplant, alternative strategies are being sought to maintain patients with end-stage cardiac failure for longer periods of time. Devices that support a failing heart, allowing cardiac recovery in some cases, or more commonly accommodate the time to source a suitable donor heart for transplantation, provide crucial therapeutic options. Extra-corporeal membrane oxygenation and ventricular assist devices are the mainstay of such bridging therapy. Although providing essential support to critically ill patients, they are not without their own significant associated risks. Therapeutic advances aim to reduce the risks associated with these bridging systems, and new artificial devices are being developed to improve this supportive care.
Collapse
Affiliation(s)
- E Siân Pincott
- Department of Cardiology, Great Ormond Street Hospital, London, WCIN 3JH, UK
| | | |
Collapse
|
37
|
Haggerty CM, Fynn-Thompson F, McElhinney DB, Valente AM, Saikrishnan N, del Nido PJ, Yoganathan AP. Experimental and numeric investigation of Impella pumps as cavopulmonary assistance for a failing Fontan. J Thorac Cardiovasc Surg 2012; 144:563-9. [DOI: 10.1016/j.jtcvs.2011.12.063] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2011] [Revised: 11/22/2011] [Accepted: 12/14/2011] [Indexed: 11/26/2022]
|
38
|
Wendell DC, Samyn MM, Cava JR, Ellwein LM, Krolikowski MM, Gandy KL, Pelech AN, Shadden SC, LaDisa JF. Including aortic valve morphology in computational fluid dynamics simulations: initial findings and application to aortic coarctation. Med Eng Phys 2012; 35:723-35. [PMID: 22917990 DOI: 10.1016/j.medengphy.2012.07.015] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2011] [Revised: 06/13/2012] [Accepted: 07/29/2012] [Indexed: 12/29/2022]
Abstract
Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to develop a method to account for the AoV in CFD simulations, and quantify its impact on local hemodynamics. The method developed facilitates segmentation of the AoV, spatiotemporal interpolation of segments, and anatomic positioning of segments at the CFD model inlet. The AoV was included in CFD model examples of a normal (tricuspid AoV) and a post-surgical CoA patient (BAV). Velocity, turbulent kinetic energy (TKE), time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) results were compared to equivalent simulations using a plug inlet profile. The plug inlet greatly underestimated TKE for both examples. TAWSS differences extended throughout the thoracic aorta for the CoA BAV, but were limited to the arch for the normal example. OSI differences existed mainly in the ascending aorta for both cases. The impact of AoV can now be included with CFD simulations to identify regions of deleterious hemodynamics thereby advancing simulations of the thoracic aorta one step closer to reality.
Collapse
Affiliation(s)
- David C Wendell
- Department of Biomedical Engineering, Marquette University, Milwaukee, WI 53233, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Pulsatile venous waveform quality affects the conduit performance in functional and "failing" Fontan circulations. Cardiol Young 2012; 22:251-62. [PMID: 22008697 DOI: 10.1017/s1047951111001491] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To investigate the effect of pulsatility of venous flow waveform in the inferior and superior caval vessels on the performance of functional and "failing" Fontan patients based on two primary performance measures - the conduit power loss and the distribution of inferior caval flow (hepatic factors) to the lungs. METHODS Doppler angiography flows were acquired from two typical extra-cardiac conduit "failing" Fontan patients, aged 13 and 25 years, with ventricle dysfunction. Using computational fluid dynamics, haemodynamic efficiencies of "failing", functional, and in vitro-generated mechanically assisted venous flow waveforms were evaluated inside an idealised total cavopulmonary connection with a caval offset. To investigate the effect of venous pulsatility alone, cardiac output was normalised to 3 litres per minute in all cases. To quantify the pulsatile behaviour of venous flows, two new performance indices were suggested. RESULTS Variations in the pulsatile content of venous waveforms altered the conduit efficiency notably. High-frequency and low-amplitude oscillations lowered the pulsatile component of the power losses in "failing" Fontan flow waveforms. Owing to the offset geometry, hepatic flow distribution depended strongly on the ratio of time-dependent caval flows and the pulsatility content rather than mixing at the junction. "Failing" Fontan flow waveforms exhibited less balanced hepatic flow distribution to lungs. CONCLUSIONS The haemodynamic efficiency of single-ventricle circulation depends strongly on the pulsatility of venous flow waveforms. The proposed performance indices can be calculated easily in the clinical setting in efforts to better quantify the energy efficiency of Fontan venous waveforms in pulsatile settings.
Collapse
|
40
|
Hunter KS, Lammers SR, Shandas R. Pulmonary vascular stiffness: measurement, modeling, and implications in normal and hypertensive pulmonary circulations. Compr Physiol 2011; 1:1413-35. [PMID: 23733649 PMCID: PMC4113421 DOI: 10.1002/cphy.c100005] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
This article introduces the concept of pulmonary vascular stiffness, discusses its increasingly recognized importance as a diagnostic marker in the evaluation of pulmonary vascular disease, and describes methods to measure and model it clinically, experimentally, and computationally. It begins with a description of systems-level methods to evaluate pulmonary vascular compliance and recent clinical efforts in applying such techniques to better predict patient outcomes in pulmonary arterial hypertension. It then progresses from the systems-level to the local level, discusses proposed methods by which upstream pulmonary vessels increase in stiffness, introduces concepts around vascular mechanics, and concludes by describing recent work incorporating advanced numerical methods to more thoroughly evaluate changes in local mechanical properties of pulmonary arteries.
Collapse
Affiliation(s)
- Kendall S. Hunter
- Department of Bioengineering, University of Colorado at Denver Anschutz Medical Campus (UCD-AMC), Aurora, Colorado
- Division of Cardiology, Department of Pediatrics, The Children’s Hospital of Denver, UCD-AMC, Aurora, Colorado
| | - Steven R. Lammers
- Department of Bioengineering, University of Colorado at Denver Anschutz Medical Campus (UCD-AMC), Aurora, Colorado
- Cardiovascular Pulmonary (CVP) Research Laboratory, UCD-AMC, Aurora, Colorado
| | - Robin Shandas
- Department of Bioengineering, University of Colorado at Denver Anschutz Medical Campus (UCD-AMC), Aurora, Colorado
- Division of Cardiology, Department of Pediatrics, The Children’s Hospital of Denver, UCD-AMC, Aurora, Colorado
- Department of Surgery, UCD-AMC, Aurora, Colorado
| |
Collapse
|
41
|
Shi Y, Lawford P, Hose R. Review of zero-D and 1-D models of blood flow in the cardiovascular system. Biomed Eng Online 2011; 10:33. [PMID: 21521508 PMCID: PMC3103466 DOI: 10.1186/1475-925x-10-33] [Citation(s) in RCA: 171] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2010] [Accepted: 04/26/2011] [Indexed: 11/16/2022] Open
Abstract
Background Zero-dimensional (lumped parameter) and one dimensional models, based on simplified representations of the components of the cardiovascular system, can contribute strongly to our understanding of circulatory physiology. Zero-D models provide a concise way to evaluate the haemodynamic interactions among the cardiovascular organs, whilst one-D (distributed parameter) models add the facility to represent efficiently the effects of pulse wave transmission in the arterial network at greatly reduced computational expense compared to higher dimensional computational fluid dynamics studies. There is extensive literature on both types of models. Method and Results The purpose of this review article is to summarise published 0D and 1D models of the cardiovascular system, to explore their limitations and range of application, and to provide an indication of the physiological phenomena that can be included in these representations. The review on 0D models collects together in one place a description of the range of models that have been used to describe the various characteristics of cardiovascular response, together with the factors that influence it. Such models generally feature the major components of the system, such as the heart, the heart valves and the vasculature. The models are categorised in terms of the features of the system that they are able to represent, their complexity and range of application: representations of effects including pressure-dependent vessel properties, interaction between the heart chambers, neuro-regulation and auto-regulation are explored. The examination on 1D models covers various methods for the assembly, discretisation and solution of the governing equations, in conjunction with a report of the definition and treatment of boundary conditions. Increasingly, 0D and 1D models are used in multi-scale models, in which their primary role is to provide boundary conditions for sophisticate, and often patient-specific, 2D and 3D models, and this application is also addressed. As an example of 0D cardiovascular modelling, a small selection of simple models have been represented in the CellML mark-up language and uploaded to the CellML model repository http://models.cellml.org/. They are freely available to the research and education communities. Conclusion Each published cardiovascular model has merit for particular applications. This review categorises 0D and 1D models, highlights their advantages and disadvantages, and thus provides guidance on the selection of models to assist various cardiovascular modelling studies. It also identifies directions for further development, as well as current challenges in the wider use of these models including service to represent boundary conditions for local 3D models and translation to clinical application.
Collapse
Affiliation(s)
- Yubing Shi
- Medical Physics Group, Department of Cardiovascular Science, Faculty of Medicine, Dentistry and Health, University of Sheffield, Sheffield S10 2RX, UK
| | | | | |
Collapse
|
42
|
Shiraishi Y, Sugai TK, Tanaka A, Yoshizawa M, Yambe T, Yamada A, Omran MH, Shiga T, Kitano T, Kamiya K, Mochizuki S, Miura H, Homma D, Yamagishi M. Structural design of a newly developed pediatric circulatory assist device for Fontan circulation by using shape memory alloy fiber. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2011:8353-8355. [PMID: 22256284 DOI: 10.1109/iembs.2011.6092060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Total cavopulmonary connection (TCPC) is commonly applied for the surgical treatment of congenital heart disease such as single ventricle in pediatric patients. Patients with no ventricle in pulmonary circulation are treated along with Fontan algorithm, in which the systemic venous return is diverted directly to the pulmonary artery without passing through subpulmonary ventricle. In order to promote the pulmonary circulation after Fontan procedure, we developed a newly designed pulmonary circulatory assist device by using shape memory alloy fibers. We developed a pulmonary circulatory assist device as a non-blood contacting mechanical support system in pediatric patients with TCPC. The device has been designed to be installed like a cuff around the ePTFE TCPC conduit, which can contract from outside. We employed a covalent type functional anisotropic shape memory alloy fiber (Biometal, Toki Corporation, Tokyo Japan) as a servo actuator of the pulmonary circulatory assist device. The diameter of this fiber was 100 microns, and its contractile frequency was 2-3 Hz. Heat generation with electric current contracts these fibers and the conduit. The maximum contraction ratio of this fiber is about 7% in length. In order to extend its contractile ratio, we fabricated and installed mechanical structural units to control the length of fibers. In this study, we examined basic contractile functions of the device in the mock system. As a result, the internal pressure of the conduit increased to 63 mmHg by the mechanical contraction under the condition of 400 msec-current supply in the mock examination with the overflow tank of 10 mmHg loading.
Collapse
Affiliation(s)
- Y Shiraishi
- Institute of Development, Aging and Cancer, Tohoku University, Sendai 980-8575, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Humpl T, Furness S, Gruenwald C, Hyslop C, Van Arsdell G. The Berlin Heart EXCOR Pediatrics-The SickKids Experience 2004-2008. Artif Organs 2010; 34:1082-6. [DOI: 10.1111/j.1525-1594.2009.00990.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
de Zélicourt DA, Marsden A, Fogel MA, Yoganathan AP. Imaging and patient-specific simulations for the Fontan surgery: current methodologies and clinical applications. PROGRESS IN PEDIATRIC CARDIOLOGY 2010; 30:31-44. [PMID: 25620865 PMCID: PMC4302339 DOI: 10.1016/j.ppedcard.2010.09.005] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Diane A. de Zélicourt
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA
| | - Alison Marsden
- Department of Mechanical and Aerospace Engineering, University of California San Diego, La Jolla, CA
| | - Mark A. Fogel
- Division of Cardiology, Children’s Hospital of Philadelphia, Philadelphia, PA
| | - Ajit P. Yoganathan
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA
| |
Collapse
|
45
|
Vignon-Clementel IE, Marsden AL, Feinstein JA. A primer on computational simulation in congenital heart disease for the clinician. PROGRESS IN PEDIATRIC CARDIOLOGY 2010. [DOI: 10.1016/j.ppedcard.2010.09.002] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
46
|
AORTIC COARCTATION: RECENT DEVELOPMENTS IN EXPERIMENTAL AND COMPUTATIONAL METHODS TO ASSESS TREATMENTS FOR THIS SIMPLE CONDITION. PROGRESS IN PEDIATRIC CARDIOLOGY 2010; 30:45-49. [PMID: 21152106 DOI: 10.1016/j.ppedcard.2010.09.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Coarctation of the aorta (CoA) is often considered a relatively simple disease, but long-term outcomes suggest otherwise as life expectancies are decades less than in the average population and substantial morbidity often exists. What follows is an expanded version of collective work conducted by the authors' and numerous collaborators that was presented at the 1st International Conference on Computational Simulation in Congenital Heart Disease pertaining to recent advances for CoA. The work begins by focusing on what is known about blood flow, pressure and indices of wall shear stress (WSS) in patients with normal vascular anatomy from both clinical imaging and the use of computational fluid dynamics (CFD) techniques. Hemodynamic alterations observed in CFD studies from untreated CoA patients and those undergoing surgical or interventional treatment are subsequently discussed. The impact of surgical approach, stent design and valve morphology are also presented for these patient populations. Finally, recent work from a representative experimental animal model of CoA that may offer insight into proposed mechanisms of long-term morbidity in CoA is presented.
Collapse
|
47
|
Tabima DM, Hacker TA, Chesler NC. Measuring right ventricular function in the normal and hypertensive mouse hearts using admittance-derived pressure-volume loops. Am J Physiol Heart Circ Physiol 2010; 299:H2069-75. [PMID: 20935149 DOI: 10.1152/ajpheart.00805.2010] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Mice are a widely used animal model for investigating cardiovascular disease. Novel technologies have been used to quantify left ventricular function in this species, but techniques appropriate for determining right ventricular (RV) function are less well demonstrated. Detecting RV dysfunction is critical to assessing the progression of pulmonary vascular diseases such as pulmonary hypertension. We used an admittance catheter to measure pressure-volume loops in anesthetized, open-chested mice before and during vena cava occlusion. Mice exposed to chronic hypoxia for 10 days, which causes hypoxia-induced pulmonary hypertension (HPH), were compared with control (CTL) mice. HPH resulted in a 27.9% increase in RV mass (P < 0.005), a 67.5% increase in RV systolic pressure (P < 0.005), and a 61.2% decrease in cardiac output (P < 0.05). Preload recruitable stroke work (PRSW) and slope of the maximum derivative of pressure (dP/dt(max))-end-diastolic volume (EDV) relationship increased with HPH (P < 0.05). Although HPH increased effective arterial elastance (E(a)) over fivefold (from 2.7 ± 1.2 to 16.4 ± 2.5 mmHg/μl), only a mild increase in the ventricular end-systolic elastance (E(es)) was observed. As a result, a dramatic decrease in the efficiency of ventricular-vascular coupling occurred (E(es)/E(a) decreased from 0.71 ± 0.27 to 0.35 ± 0.17; P < 0.005). Changes in cardiac reserve were evaluated by dobutamine infusion. In CTL mice, dobutamine significantly enhanced E(es) and dP/dt(max)-EDV but also increased E(a), causing a decrease in E(es)/E(a). In HPH mice, slight but nonsignificant decreases in E(es), PRSW, dP/dt(max)-EDV, and E(a) were observed. Thus 10 days of HPH resulted in RV hypertrophy, ventricular-vascular decoupling, and a mild decrease in RV contractile reserve. This study demonstrates the feasibility of obtaining RV pressure-volume measurements in mice. These measurements provide insight into ventricular-vascular interactions healthy and diseased states.
Collapse
Affiliation(s)
- Diana M Tabima
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706-1609, USA
| | | | | |
Collapse
|
48
|
Dur O, DeGroff CG, Keller BB, Pekkan K. Optimization of inflow waveform phase-difference for minimized total cavopulmonary power loss. J Biomech Eng 2010; 132:031012. [PMID: 20459200 DOI: 10.1115/1.4000954] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The Fontan operation is a palliative surgical procedure performed on children, born with congenital heart defects that have yielded only a single functioning ventricle. The total cavo-pulmonary connection (TCPC) is a common variant of the Fontan procedure, where the superior vena cava (SVC) and inferior vena cava (IVC) are routed directly into the pulmonary arteries (PA). Due to the limited pumping energy available, optimized hemodynamics, in turn, minimized power loss, inside the TCPC pathway is required for the best optimal surgical outcomes. To complement ongoing efforts to optimize the anatomical geometric design of the surgical Fontan templates, here, we focused on the characterization of power loss changes due to the temporal variations in between SVC and IVC flow waveforms. An experimentally validated pulsatile computational fluid dynamics solver is used to quantify the effect of phase-shift between SVC and IVC inflow waveforms and amplitudes on internal energy dissipation. The unsteady hemodynamics of two standard idealized TCPC geometries are presented, incorporating patient-specific real-time PC-MRI flow waveforms of "functional" Fontan patients. The effects of respiration and pulsatility on the internal energy dissipation of the TCPC pathway are analyzed. Optimization of phase-shift between caval flows is shown to lead to lower energy dissipation up to 30% in these idealized models. For physiological patient-specific caval waveforms, the power loss is reduced significantly (up to 11%) by the optimization of all three major harmonics at the same mean pathway flow (3 L/min). Thus, the hemodynamic efficiency of single ventricle circuits is influenced strongly by the caval flow waveform quality, which is regulated through respiratory dependent physiological pathways. The proposed patient-specific waveform optimization protocol may potentially inspire new therapeutic applications to aid postoperative hemodynamics and improve the well being of the Fontan patients.
Collapse
Affiliation(s)
- Onur Dur
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA 15219, USA
| | | | | | | |
Collapse
|
49
|
Dur O, Lara M, Arnold D, Vandenberghe S, Keller BB, DeGroff C, Pekkan K. Pulsatile In Vitro Simulation of the Pediatric Univentricular Circulation for Evaluation of Cardiopulmonary Assist Scenarios. Artif Organs 2009; 33:967-76. [DOI: 10.1111/j.1525-1594.2009.00951.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
50
|
Throckmorton AL, Kishore RA. Design of a Protective Cage for an Intravascular Axial Flow Blood Pump to Mechanically Assist the Failing Fontan. Artif Organs 2009; 33:611-21. [DOI: 10.1111/j.1525-1594.2009.00779.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|