1
|
Schramm JE, Dykes JC, Hopper RK, Feinstein JA, Rosenthal DN, Kameny RJ. Pulmonary Vasodilator Therapy in Pediatric Patients on Ventricular Assist Device Support: A Single-Center Experience and Proposal for Use. ASAIO J 2023; 69:1025-1030. [PMID: 37556563 DOI: 10.1097/mat.0000000000002023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2023] Open
Abstract
Pediatric precapillary pulmonary hypertension can develop in response to systemic atrial hypertension. Systemic atrial decompression following ventricular assist device (VAD) implantation may not sufficiently lower pulmonary vascular resistance (PVR) to consider heart transplant candidacy. Prostacyclins have been used in adult VAD patients with success, but pediatric data on safety and efficacy in this population are limited. We sought to describe our center's experience to show its safety and to present our current protocol for perioperative use. We reviewed our use of prostacyclin therapy in pediatric patients on VAD support with high PVR from 2016 to 2021. Of the 17 patients who met inclusion, 12 survived to transplant and 1 is alive with VAD in situ . All patients survived posttransplant. With continuous intravenous (IV) epoprostenol or treprostinil therapy, there were no bleeding complications or worsening of end-organ function. A significant reduction was observed in vasoactive inotropic scores by 49% in the first 24 hours post-prostacyclin initiation. The proportion of patients surviving to transplant in this high-risk cohort is favorable. In conclusion, prostacyclins may be safe to use in patients with elevated PVR as part of their VAD and transplant course and may provide a transplant option in those otherwise not candidates.
Collapse
Affiliation(s)
- Jennifer E Schramm
- From the Department of Anesthesia and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - John C Dykes
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Palo Alto, California
| | - Rachel K Hopper
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Palo Alto, California
| | - Jeffrey A Feinstein
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Palo Alto, California
| | - David N Rosenthal
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Palo Alto, California
| | - Rebecca J Kameny
- Department of Pediatrics (Cardiology), Stanford University School of Medicine, Palo Alto, California
| |
Collapse
|
2
|
Roy S, Kloner RA, Salloum FN, Jovin IS. Cardiac Effects of Phosphodiesterase-5 Inhibitors: Efficacy and Safety. Cardiovasc Drugs Ther 2023; 37:793-806. [PMID: 34652581 PMCID: PMC9010479 DOI: 10.1007/s10557-021-07275-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/01/2021] [Indexed: 01/23/2023]
Abstract
The coexistence of cardiovascular disease and erectile dysfunction is widespread, possibly owing to underlying endothelial dysfunction in both diseases. Millions of patients with cardiovascular disease are prescribed phosphodiesterase-5 (PDE5) inhibitors for the management of erectile dysfunction. Although the role of PDE5 inhibitors in erectile dysfunction therapy is well established, their effects on the cardiovascular system are unclear. Preclinical studies investigating the effect of PDE5 inhibitors on ischemia-reperfusion injury, pressure overload-induced hypertrophy, and chemotoxicity suggested a possible clinical role for each of these medications; however, attempts to translate these findings to the bedside have resulted in mixed outcomes. In this review, we explore the biologic preclinical effects of PDE5 inhibitors in mediating cardioprotection. We then examine clinical trials investigating PDE5 inhibition in patients with heart failure, coronary artery disease, and ventricular arrhythmias and discuss why the studies likely have yet to show positive results and efficacy with PDE5 inhibition despite no safety concerns.
Collapse
Affiliation(s)
- Sumon Roy
- Pauley Heart Center, Virginia Commonwealth University Medical Center, McGuire VAMC, 1201 Broad Rock Boulevard, 111J, Richmond, VA, 23249, USA
| | - Robert A Kloner
- Huntington Medical Research Institute, Pasadena, CA, USA
- Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Fadi N Salloum
- Pauley Heart Center, Virginia Commonwealth University Medical Center, McGuire VAMC, 1201 Broad Rock Boulevard, 111J, Richmond, VA, 23249, USA
| | - Ion S Jovin
- Pauley Heart Center, Virginia Commonwealth University Medical Center, McGuire VAMC, 1201 Broad Rock Boulevard, 111J, Richmond, VA, 23249, USA.
- McGuire Veterans Affairs Medical Center, Richmond, VA, USA.
| |
Collapse
|
3
|
Neurologic Complications in Patients With Left Ventricular Assist Devices. Can J Cardiol 2023; 39:210-221. [PMID: 36400374 PMCID: PMC9905352 DOI: 10.1016/j.cjca.2022.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 11/10/2022] [Accepted: 11/10/2022] [Indexed: 11/16/2022] Open
Abstract
Left ventricular assist device (LVAD) use has revolutionised the care of patients with advanced heart failure, allowing more patients to survive until heart transplantation and providing improved quality for patients unable to undergo transplantation. Despite these benefits, improvements in device technology, and better clinical care and experience, LVADs are associated with neurologic complications. This review provides information on the incidence, risk factors, and management of neurologic complications among LVAD patients. Although scant guidelines exist for the evaluation and management of neurologic complications in LVAD patients, a high index of suspicion can prompt early detection of neurologic complications which may improve overall neurologic outcomes. A better understanding of the implications of continuous circulatory flow on systemic and cerebral vasculature is necessary to reduce the common occurrence of neurologic complications in this population.
Collapse
|
4
|
Post-Implant Phosphodiesterase-5 Inhibitors in Patients with Left Ventricular Assist Device: A Systematic Review and Meta-Analysis. J Clin Med 2022; 11:jcm11205988. [PMID: 36294308 PMCID: PMC9604415 DOI: 10.3390/jcm11205988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 10/04/2022] [Accepted: 10/09/2022] [Indexed: 11/17/2022] Open
Abstract
Background: Despite the improvement in left ventricular assist device (LVAD) technology and the advent of third-generation LVADs, hemocompatibility-related events remain a significant issue. Therefore, new pharmacological treatments are necessary to optimize patient management and to further reduce hemocompatibility-related events. The purpose of the present systematic review and meta-analysis was to summarize the existing data regarding the safety and efficacy of post-implant phosphodiesterase-5 inhibitors (PDE-5i) on hemocompatibility-related events. Methods: Among the 258 articles in Pubmed, Scopus, and CENTRAL that were retrieved (1990−2022), 15 studies were included in the qualitative synthesis, and 9 studies were included in the quantitative synthesis. The fixed-effects model was used because it is statistically sound for combining a very small number of studies. The primary endpoint of the study was all-cause mortality, whereas the secondary endpoints were ischemic stroke, pump thrombosis, and gastrointestinal bleeding. Results: Mortality was significantly lower in the PDE-5i group vs. the control group (OR: 0.92 [95% CI: 0.85, 0.98]; p = 0.02). The secondary endpoints ischemic stroke (OR: 0.87 [95% CI: 0.78, 0.98]; p = 0.02) and pump thrombosis (OR: 0.90 [95% CI: 0.82, 0.99]; p = 0.04) were also lower in the PDE-5i group. The incidence of gastrointestinal bleeding was significantly higher in patients with LVAD receiving PDE-5i (OR: 1.26 [95% CI: 1.11, 1.44]; p < 0.01). In the overall analysis, the heterogeneity of outcomes was low, except for pump thrombosis. Conclusions: The use of PDE-5i post-implant was associated with lower mortality and thrombotic events but with a higher risk of gastrointestinal bleeding.
Collapse
|
5
|
Grandin EW, Gulati G, Nunez JI, Kennedy K, Rame JE, Atluri P, Pagani FD, Kirklin JK, Kormos RL, Teuteberg J, Kiernan M. Outcomes With Phosphodiesterase-5 Inhibitor Use After Left Ventricular Assist Device: An STS-INTERMACS Analysis. Circ Heart Fail 2022; 15:e008613. [PMID: 35332780 PMCID: PMC9205418 DOI: 10.1161/circheartfailure.121.008613] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 12/17/2021] [Indexed: 11/16/2022]
Abstract
BACKGROUND Elevated right ventricular afterload following continuous-flow left ventricular assist device (CF-LVAD) may contribute to late right heart failure (LRHF). PDE5i (phosphodiesterase-5 inhibitors) are used to treat pulmonary hypertension and right heart dysfunction after CF-LVAD, but their impact on outcomes is uncertain. METHODS We queried Interagency Registry for Mechanically Assisted Circulatory Support from 2012 to 2017 for adults receiving a primary CF-LVAD and surviving ≥30 days from index discharge. Patients receiving early PDE5i (ePDE5i) at 1 month were propensity-matched 1:1 with controls. The primary outcome was the cumulative incidence of LRHF, defined using prevailing Interagency Registry for Mechanically Assisted Circulatory Support criteria; secondary outcomes included all-cause mortality and major bleeding. RESULTS Among 9627 CF-LVAD recipients analyzed, 2463 (25.6%) received ePDE5i and 1600 were propensity-matched 1:1 with controls. Before implant, ePDE5i patients had more severe RV dysfunction (13.1% versus 9.6%) and higher pulmonary vascular resistance (2.8±2.7 versus 2.2±2.4 WU), both P<0.001, but clinical factors were well-balanced after propensity-matching. In the unmatched cohort, ePDE5i patients had a higher 3-year cumulative incidence of LRHF, mortality, and major bleeding, but these differences were attenuated in the propensity-matched cohort: LRHF 40.8% versus 35.7% (hazard ratio, 1.14 [95% CI, 0.99-1.32]; P=0.07); mortality 38.6% versus 35.8% (hazard ratio, 0.99 [95% CI, 0.86-1.15]; P=0.93); major bleeding 51.2% versus 46.0% (hazard ratio, 1.12 [95% CI, 0.99-1.27]; P=0.06). CONCLUSIONS Compared with propensity-matched controls, adult CF-LVAD patients receiving ePDE5i had similar rates of LRHF, mortality, and major bleeding. While intrinsic patient risk factors likely account for more adverse outcomes with ePDE5i in the unmatched cohort, there is no obvious benefit of ePDE5i in the LVAD population.
Collapse
Affiliation(s)
- E. Wilson Grandin
- Cardiovascular Institute, Beth Israel Deaconess Medical Center, Boston MA
- Smith Center for Outcomes Research in Cardiology, Beth Israel Deaconess Medical Center, Boston MA
| | - Gaurav Gulati
- Cardiovascular Center, Tufts Medical Center, Boston MA
| | - Jose I Nunez
- Cardiovascular Institute, Beth Israel Deaconess Medical Center, Boston MA
| | - Kevin Kennedy
- Smith Center for Outcomes Research in Cardiology, Beth Israel Deaconess Medical Center, Boston MA
| | - J Eduardo Rame
- Division of Cardiology, Jefferson Heart Institute, Philadelphia, PA
| | - Pavan Atluri
- Division of Cardiothoracic Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA
| | - Francis D Pagani
- Division of Cardiothoracic Surgery, University of Michigan School of Medicine, Ann Arbor, MI
| | - James K Kirklin
- Division of Cardiothoracic Surgery, University of Alabama Birmingham School of Medicine, Birmingham, AL
| | - Robert L Kormos
- Division of Cardiothoracic Surgery, University of Pittsburgh; Abbott Laboratories, Austin, TX
| | - Jeffrey Teuteberg
- Division of Cardiovascular Medicine, Stanford University Medical Center, Stanford, CA
| | | |
Collapse
|
6
|
Xanthopoulos A, Wolski K, Wang Q, Blackstone EH, Randhawa VK, Soltesz EG, Young JB, Nissen SE, Estep JD, Triposkiadis F, Starling RC. Postimplant Phosphodiesterase-5 Inhibitor Use in Centrifugal Flow Left Ventricular Assist Devices. JACC. HEART FAILURE 2022; 10:89-100. [PMID: 35115092 DOI: 10.1016/j.jchf.2021.09.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 09/24/2021] [Accepted: 09/28/2021] [Indexed: 12/20/2022]
Abstract
OBJECTIVES This study examined the association between phosphodiesterase-5 inhibitor (PDE-5i) use and outcomes in patients with contemporary centrifugal flow left ventricular assist devices (LVADs). BACKGROUND PDE-5i use may affect outcomes in patients with continuous flow LVADs. METHODS Patients enrolled in INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support), with HeartMate 3 (n = 4,628) or HeartWare Ventricular Assist Device (HVAD) (n = 2,601) implant were included in the analysis. The mean duration of follow-up was 11.94 ± 8.65 months. PDE-5is were used in 2,173 patients. The primary endpoint was the composite of all-cause mortality, ischemic stroke, and pump thrombosis. Propensity matching and stabilized inverse probability of treatment weights were used to adjust for baseline differences between patients receiving and not receiving PDE-5i. Adjusted Cox proportional hazards analysis was performed for each outcome. RESULTS The primary endpoint was lower in the PDE-5i group (adjusted HR: 0.77; 95% CI: 0.69-0.86; P < 0.0001; HeartMate 3: adjusted HR: 0.77; 95% CI: 0.64-0.92; P = 0.0044; HVAD: adjusted HR: 0.76; 95% CI: 0.66-0.88; P = 0.0002). All-cause mortality was lower with PDE-5is (adjusted HR: 0.75; 95% CI: 0.65-0.86; P < 0.0001; HeartMate 3: adjusted HR: 0.70; 95% CI: 0.57-0.86; P = 0.0007; HVAD: adjusted HR: 0.78; 95% CI: 0.65-0.94; P = 0.0098) and fewer ischemic strokes with PDE-5is were observed (adjusted HR: 0.71; 95% CI: 0.56-0.89; P = 0.003; HeartMate 3: adjusted HR: 0.67; 95% CI: 0.45-0.99; P = 0.045; HVAD: adjusted HR: 0.73; 95% CI: 0.56-0.97; P = 0.03). LVAD thrombosis was unchanged with PDE-5is, with overall low event rates observed. CONCLUSIONS Postimplant PDE-5i use was associated with lower mortality and ischemic strokes in patients with centrifugal flow LVADs.
Collapse
Affiliation(s)
- Andrew Xanthopoulos
- Department of Cardiology, University General Hospital of Larissa, Larissa, Greece
| | - Kathy Wolski
- Department of Cardiovascular Medicine, Cleveland Clinic Coordinating Center for Clinical Research, Heart, Vascular, and Thoracic Institute, Cleveland, Ohio, USA
| | - Qiuqing Wang
- Department of Cardiovascular Medicine, Cleveland Clinic Coordinating Center for Clinical Research, Heart, Vascular, and Thoracic Institute, Cleveland, Ohio, USA
| | - Eugene H Blackstone
- Department of Thoracic and Cardiovascular Surgery, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Varinder Kaur Randhawa
- Kaufman Center for Heart Failure Treatment and Recovery, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Edward G Soltesz
- Kaufman Center for Heart Failure Treatment and Recovery, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - James B Young
- Kaufman Center for Heart Failure Treatment and Recovery, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Steven E Nissen
- Department of Cardiovascular Medicine, Cleveland Clinic Coordinating Center for Clinical Research, Heart, Vascular, and Thoracic Institute, Cleveland, Ohio, USA
| | - Jerry D Estep
- Kaufman Center for Heart Failure Treatment and Recovery, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | | | - Randall C Starling
- Kaufman Center for Heart Failure Treatment and Recovery, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
| |
Collapse
|
7
|
Pirlamarla P, Rame E, Hoopes C, Rajapreyar I. Pulmonary vasodilator use in continuous-flow left ventricular assist device management. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:522. [PMID: 33850919 PMCID: PMC8039680 DOI: 10.21037/atm-20-4710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Pulmonary hypertension (PH) due to left heart disease is the most common etiology for PH. PH in patients with heart failure with reduced fraction (HFrEF) is associated with reduced functional capacity and increased mortality. PH-HFrEF can be isolated post-capillary or combined pre- and post-capillary PH. Chronic elevation of left-sided filling pressures may lead to reverse remodeling of the pulmonary vasculature with development of precapillary component of PH. Untreated PH in patients with HFrEF results in predominant right heart failure (RHF) with irreversible end-organ dysfunction. Management of PH-HFrEF includes diuretics, vasodilators like angiotensin-converting enzyme inhibitors or angiotensin-receptor blockers or angiotensin-receptor blocker-neprilysin inhibitors, hydralazine and nitrates. There is no role for pulmonary vasodilator use in patients with PH-HFrEF due to increased mortality in clinical trials. In patients with end-stage HFrEF and fixed PH unresponsive to vasodilator challenge, implantation of continuous-flow left ventricular assist device (cfLVAD) results in marked improvement in pulmonary artery pressures within 6 months due to left ventricular (LV) mechanical unloading. The role of pulmonary vasodilators in management of precapillary component of PH after cfLVAD is not well-defined. The purpose of this review is to discuss the pharmacologic management of PH after cfLVAD implantation.
Collapse
Affiliation(s)
- Preethi Pirlamarla
- Advanced Heart Failure and Transplant Cardiology, Sidney Kimmel Medical College, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| | - Eduardo Rame
- Advanced Heart Failure and Transplant Cardiology, Sidney Kimmel Medical College, Thomas Jefferson University Hospital, Philadelphia, PA, USA
| | - Charles Hoopes
- Division of Cardiothoracic Surgery, Department of Surgery, School of Medicine, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Indranee Rajapreyar
- Division of Cardiovascular Disease, Department of Medicine, University of Alabama-Birmingham School of Medicine, Birmingham, AL, USA
| |
Collapse
|
8
|
Kittipibul V, Blumer V, Angsubhakorn N, Hernandez GA, Chaparro S, Tedford RJ, Agarwal R. Phosphodiesterase-5 Inhibitors and Outcomes During Left Ventricular Assist Device Support: A Systematic Review and Meta-Analysis. J Card Fail 2020; 27:477-485. [PMID: 33385522 DOI: 10.1016/j.cardfail.2020.12.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 12/15/2020] [Accepted: 12/22/2020] [Indexed: 12/31/2022]
Abstract
BACKGROUND Phosphodiesterase-5 inhibitors (PDE5i) have been used to treat pulmonary hypertension and right ventricular failure in patients with left ventricular assist devices (LVAD). The effects of PDE5i on post-LVAD outcomes including hemocompatibility-related adverse events are not well-established. This systematic review and meta-analysis aims to evaluate the effects of PDE5i on post-LVAD outcomes. METHODS AND RESULTS A comprehensive literature search was conducted using Pubmed and Embase databases from inception through November 25, 2020, to compare post-LVAD outcomes in patients with or without PDE5i use. Pooled odds ratio (OR) with 95% confidence intervals (CI) and I2 statistic were calculated. Thirteen observational studies were included in this analysis. The use of PDE5i was not significantly associated with lower postoperative right ventricular failure (OR 0.38, 95% CI 0.02-5.96, P = .41). There was no significant association between PDE5i and gastrointestinal bleeding (OR 1.23, 95% CI 0.76-1.98, P = .2), overall stroke (OR 0.60, 95% CI 0.21-1.68, P = .17), ischemic stroke (OR 0.61, 95% CI 0.09-4.07, P = .38), or pump thrombosis (OR 0.71, 95% CI 0.14-3.54, P = .46). CONCLUSIONS Our meta-analysis showed no significant association between PDE5i and post-LVAD right ventricular failure. Despite the antiplatelet effects of PDE5i, there was no significant association between PDE5i and gastrointestinal bleeding, overall stroke, ischemic stroke, or pump thrombosis. Randomized controlled studies are warranted to evaluate the net benefits or harms of PDE5i in the LVAD population.
Collapse
Affiliation(s)
- Veraprapas Kittipibul
- Department of Medicine, University of Miami/Jackson Memorial Hospital, Miami, Florida
| | - Vanessa Blumer
- Division of Cardiology, Duke University Medical Center, Durham, North Carolina
| | | | - Gabriel A Hernandez
- Division of Cardiology, University of Mississippi Medical Center, Jackson, Mississippi
| | - Sandra Chaparro
- Advanced Heart Failure Program, Baptist Health South Florida, Miami, Florida
| | - Ryan J Tedford
- Division of Cardiology, Medical University of South Carolina, Charleston, South Carolina
| | - Richa Agarwal
- Division of Cardiology, Duke University Medical Center, Durham, North Carolina.
| |
Collapse
|
9
|
Hamdan R, Fakih S, Mohammad M, Charif F, Abdallah H, Safa S, Al Ali F, Issa M, Damen B, El Zein A, Younes M, Rabah A, Saab M. The Lebanese left ventricular assist device experience, a success story despite the odds. J Cardiothorac Surg 2020; 15:192. [PMID: 32723392 PMCID: PMC7388207 DOI: 10.1186/s13019-020-01235-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 07/20/2020] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND AND AIM Heart failure is still a leading cause of mortality and morbidity. Assist devices are reserved for advanced heart failure patients with no other therapeutic options. We aim in this paper to describe the characteristics and outcome of Lebanese left ventricular assist device (LVAD) patients. RESULTS From 2010 till December 2019, 78 patients were implanted with assist devices at the Beirut cardiac Institute, 82 pumps were used. To the most recent follow up after 10 years, 26 patients died (34%). 24 patients of 35 (68%) survived more than 5 years. Seven patients only (9%) died during one month of surgery. One year mortality was 19% (15 patients). The leading cause of early mortality was infection, whereas cerebrovascular accidents CVA were the leading cause of late mortality. Pump thrombosis occurred in 12% of the cases. The most serious long term complication was haemorrhagic CVA. Only seven patients (9%) received heart transplantation, with a mean time on support prior to transplantation of 1303 ± 213 days. CONCLUSION In this manuscript we reported the characteristics and outcome of the largest population of LVAD patients in Lebanon. The survival rate was 81% at one year. These findings were comparable to the international registries except for rates of heart transplantation. More efforts should be made to encourage organ donation in Lebanon.
Collapse
Affiliation(s)
- R Hamdan
- Cardiology department, Beirut Cardiac Institute, Beirut, Lebanon.
| | - S Fakih
- Cardiology fellow, Cardiology department, Beirut Cardiac Institute, Beirut, Lebanon
| | - M Mohammad
- Lebanese Society of Cardiology, Cardiology department, Bahman Hospital, Beirut, Lebanon
| | - F Charif
- Critical care unit, Beirut Cardiac Institute, Beirut, Lebanon
| | - H Abdallah
- Cockrell school of engineering, University of Texas, Austin, TX, USA
| | - S Safa
- Cardiology fellow, Cardiology department, Beirut Cardiac Institute, Beirut, Lebanon
| | - F Al Ali
- Cardiac surgeon, Cardiac Surgery department, Beirut Cardiac Institute, Beirut, Lebanon
| | - M Issa
- Cardiac Surgery department, Beirut Cardiac Institute, Beirut, Lebanon
| | - B Damen
- Cardiac Surgery department, Beirut Cardiac Institute, Beirut, Lebanon
| | - A El Zein
- Cardiac Surgery department, Beirut Cardiac Institute, Beirut, Lebanon
| | - M Younes
- Cardiology department, Beirut Cardiac Institute, Beirut, Lebanon
| | - A Rabah
- Cardiac Surgery department, Beirut Cardiac Institute, Beirut, Lebanon
| | - M Saab
- Cardiac Surgery department, Beirut Cardiac Institute, Beirut, Lebanon
| |
Collapse
|
10
|
Xanthopoulos A, Tryposkiadis K, Triposkiadis F, Fukamachi K, Soltesz EG, Young JB, Wolski K, Blackstone EH, Starling RC. Postimplant Phosphodiesterase Type 5 Inhibitors Use Is Associated With Lower Rates of Thrombotic Events After Left Ventricular Assist Device Implantation. J Am Heart Assoc 2020; 9:e015897. [PMID: 32648508 PMCID: PMC7660717 DOI: 10.1161/jaha.119.015897] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Background Left ventricular assist device (LVAD) thrombosis is clinically devastating and impacts the cost effectiveness of LVAD therapy for advanced heart failure. Anticoagulation and antiplatelet therapies represent the standard of care to mitigate LVAD thrombosis. Phosphodiesterase type 5 inhibitors (PDE-5is) exhibit hemodynamic, antiplatelet, and antithrombotic effects. Using a national registry, we examined the relationship of PDE-5i use on thrombotic events in patients with continuous-flow LVADs. Methods and Results We obtained data from 13 772 patients with continuous flow LVADs participating in a national registry. Patients implanted with primary LVADs from 2012 to 2017 were included in the analysis. The primary end point was a composite of LVAD thrombosis and ischemic stroke. Patients were analyzed according to any use of PDE-5i after LVAD implantation (PDE-5i group) versus no use after LVAD implantation (no PDE-5i group). The primary end point was significantly lower in the PDE-5i group compared with the no PDE-5i group (hazard ratio [HR], 0.84; 95% CI, 0.77-0.91; P<0.001) at 48 months. The components of the primary end point (LVAD thrombosis: HR, 0.82; 95% CI, 0.74-0.90; P<0.001; and ischemic stroke: HR, 0.85; 95% CI, 0.75-0.97; P=0.019), as well as the secondary end point all-cause mortality (HR, 0.86; 95% CI, 0.79-0.93; P<0.001) were lower in the PDE-5i group versus the no PDE-5i at 48 months post LVAD. The favorable results observed with postimplant PDE-5i use were consistent with both axial and centrifugal flow devices. Conclusions The postimplant use of PDE-5i was associated with fewer thrombotic events and improved survival in LVAD patients. A randomized clinical trial is warranted to confirm these findings.
Collapse
Affiliation(s)
- Andrew Xanthopoulos
- Kaufman Center for Heart Failure, Heart and Vascular Institute Cleveland Clinic Cleveland OH
| | | | | | - Kiyotaka Fukamachi
- Kaufman Center for Heart Failure, Heart and Vascular Institute Cleveland Clinic Cleveland OH
| | - Edward G Soltesz
- Kaufman Center for Heart Failure, Heart and Vascular Institute Cleveland Clinic Cleveland OH
| | - James B Young
- Kaufman Center for Heart Failure, Heart and Vascular Institute Cleveland Clinic Cleveland OH
| | - Kathy Wolski
- Kaufman Center for Heart Failure, Heart and Vascular Institute Cleveland Clinic Cleveland OH
| | - Eugene H Blackstone
- Kaufman Center for Heart Failure, Heart and Vascular Institute Cleveland Clinic Cleveland OH
| | - Randall C Starling
- Kaufman Center for Heart Failure, Heart and Vascular Institute Cleveland Clinic Cleveland OH
| |
Collapse
|