1
|
Burgos CM, Frenckner B, Broman LM. Premature and Extracorporeal Life Support: Is it Time? A Systematic Review. ASAIO J 2022; 68:633-645. [PMID: 34593681 DOI: 10.1097/mat.0000000000001555] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Early preterm birth < 34 gestational weeks (GA) and birth weight (BW) <2 kg are relative contraindications for extracorporeal membrane oxygenation (ECMO). However, with improved technology, ECMO is presently managed more safely and with decreasing complications. Thus, these relative contraindications may no longer apply. We performed a systematic review to evaluate the existing literature on ECMO in early and late (34-37 GA) prematurity focusing on survival to hospital discharge and the complication intracranial hemorrhage (ICH). Data sources: MEDLINE, PubMed, Web of Science, Embase, and the Cochrane Database. Only publications in the English language were evaluated. Of the 36 included studies, 23 were related to ECMO support for respiratory failure, 10 for cardiac causes, and four for congenital diaphragmatic hernia (CDH). Over the past decades, the frequency of ICH has declined (89-21%); survival has increased in both early prematurity (25-76%), and in CDH (33-75%), with outcome similar to late prematurity (48%). The study was limited by an inherent risk of bias from overlapping single-center and registry data. Both the risk of ICH and death have decreased in prematurely born treated with ECMO. We challenge the 34 week GA time limit for ECMO and propose an international task force to revise current guidelines. At present, gestational age < 34 weeks might no longer be considered a contraindication for ECMO in premature neonates.
Collapse
Affiliation(s)
- Carmen Mesas Burgos
- From the Department of Pediatric Surgery, Karolinska University Hospital, Stockholm, Sweden
- ECMO Centre Karolinska, Pediatric Perioperative Medicine and Intensive Care, Astrid Lindgren Children's Hospital, Karolinska University Hospital, Stockholm, Sweden
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Björn Frenckner
- From the Department of Pediatric Surgery, Karolinska University Hospital, Stockholm, Sweden
- ECMO Centre Karolinska, Pediatric Perioperative Medicine and Intensive Care, Astrid Lindgren Children's Hospital, Karolinska University Hospital, Stockholm, Sweden
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Lars Mikael Broman
- ECMO Centre Karolinska, Pediatric Perioperative Medicine and Intensive Care, Astrid Lindgren Children's Hospital, Karolinska University Hospital, Stockholm, Sweden
- Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
2
|
Loverro MT, Di Naro E, Nicolardi V, Resta L, Mastrolia SA, Schettini F, Capozza M, Loverro M, Loverro G, Laforgia N. Pregnancy Complications, Correlation With Placental Pathology and Neonatal Outcomes. FRONTIERS IN CLINICAL DIABETES AND HEALTHCARE 2022; 2:807192. [PMID: 36994339 PMCID: PMC10012052 DOI: 10.3389/fcdhc.2021.807192] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 12/06/2021] [Indexed: 11/13/2022]
Abstract
PurposeWe aimed to clarify and contribute to a better comprehension of associations and correlations between placental histological findings, pregnancy evolution, and neonatal outcomes.Study DesignThis is a longitudinal and prospective observational study, performed between May 2015 and May 2019, on 506 pregnant women. Clinical data related to pregnancy outcome, neonatal health status, and placental histology were primarily collected. Twin pregnancies or malformed newborns were excluded and therefore the study was conducted on 439 cases. These cases have been then subdivided into the following study groups: (a) 282 placentas from pathological pregnancies; and, (b) a control group of 157 pregnancies over 33 weeks of gestational age, defined as physiological or normal pregnancies due to the absence of maternal, fetal, and early neonatal pathologies, most of which had undergone elective cesarean section for maternal or fetal indication.ResultsA normal placenta was present in 57.5% of normal pregnancies and in 42.5% of pathological pregnancies. In contrast, placental pathology was present in 26.2% of normal pregnancies and 73.8% of pathological pregnancies. Comparison of the neonatal health status with the pregnancy outcome showed that, among the 191 newborns classified as normal, 98 (51.3%) were born from a normal pregnancy, while 93 (48.7%) were born from mothers with a pathological pregnancy. Among the 248 pathological infants, 59 (23.8%) were born from a mother with a normal pregnancy, while 189 (76.2%) were born from pregnancies defined as pathological.ConclusionPlacental histology must be better understood in the context of natural history of disease. Retrospective awareness of placental damage is useful in prevention in successive pregnancy, but their early identification in the evolving pregnancy could help in association with biological markers or more sophisticated instruments for early diagnosis.
Collapse
Affiliation(s)
- Maria Teresa Loverro
- Department of Biomedical Science and Human Oncology, Section of Neonatology and Neonatal Intensive Care, Azienda Ospedaliero-Universitaria Policlinico di Bari, School of Medicine, University of Bari “Aldo Moro”, Bari, Italy
| | - Edoardo Di Naro
- Department Interdisciplinary Medicine, Unit of Obstetrics and Gynecology, Azienda Ospedaliero-Universitaria Policlinico di Bari, School of Medicine, University of Bari “Aldo Moro”, Bari, Italy
| | - Vittorio Nicolardi
- Department of Economics and Finance University of Bari “Aldo Moro”, Bari, Italy
| | - Leonardo Resta
- Department Emergency and Organ Transplantation, Institute of Pathology, Azienda Ospedaliero-Universitaria Policlinico di Bari, School of Medicine, University of Bari “Aldo Moro”, Bari, Italy
| | - Salvatore Andrea Mastrolia
- Department of Obstetrics and Gynecology, Ospedale dei Bambini “Vittore Buzzi”, University of Milan, Milan, Italy
- *Correspondence: Salvatore Andrea Mastrolia,
| | - Federico Schettini
- Department of Biomedical Science and Human Oncology, Section of Neonatology and Neonatal Intensive Care, Azienda Ospedaliero-Universitaria Policlinico di Bari, School of Medicine, University of Bari “Aldo Moro”, Bari, Italy
| | - Manuela Capozza
- Department of Biomedical Science and Human Oncology, Section of Neonatology and Neonatal Intensive Care, Azienda Ospedaliero-Universitaria Policlinico di Bari, School of Medicine, University of Bari “Aldo Moro”, Bari, Italy
| | - Matteo Loverro
- Department of Women and Child Health, Fondazione Policlinico Universitario Agostino Gemelli Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Giuseppe Loverro
- Department Interdisciplinary Medicine, Unit of Obstetrics and Gynecology, Azienda Ospedaliero-Universitaria Policlinico di Bari, School of Medicine, University of Bari “Aldo Moro”, Bari, Italy
| | - Nicola Laforgia
- Department of Biomedical Science and Human Oncology, Section of Neonatology and Neonatal Intensive Care, Azienda Ospedaliero-Universitaria Policlinico di Bari, School of Medicine, University of Bari “Aldo Moro”, Bari, Italy
| |
Collapse
|
3
|
van der Hout-van der Jagt MB, Verweij EJT, Andriessen P, de Boode WP, Bos AF, Delbressine FLM, Eggink AJ, Erwich JJHM, Feijs LMG, Groenendaal F, Kramer BWW, Lely AT, Loop RFAM, Neukamp F, Onland W, Oudijk MA, te Pas AB, Reiss IKM, Schoberer M, Scholten RR, Spaanderman MEA, van der Ven M, Vermeulen MJ, van de Vosse FN, Oei SG. Interprofessional Consensus Regarding Design Requirements for Liquid-Based Perinatal Life Support (PLS) Technology. Front Pediatr 2022; 9:793531. [PMID: 35127593 PMCID: PMC8809135 DOI: 10.3389/fped.2021.793531] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 12/14/2021] [Indexed: 12/23/2022] Open
Abstract
Liquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design. The aim of this paper is to provide a framework for research and development of PLS technology. These requirements are considering the possible respective user perspectives, with the aim to co-create a PLS system that facilitates physiological growth and development for extremely preterm born infants.
Collapse
Affiliation(s)
- M. Beatrijs van der Hout-van der Jagt
- Department of Obstetrics and Gynecology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - E. J. T. Verweij
- Department of Obstetrics and Gynecology, Division of Fetal Therapy, Leiden University Medical Center (LUMC), Leiden, Netherlands
| | - Peter Andriessen
- Department of Neonatology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Applied Physics, School of Medical Physics and Engineering Eindhoven, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Willem P. de Boode
- Division of Neonatology, Department of Perinatology, Radboud University Medical Center, Radboud Institute for Health Sciences, Amalia Children's Hospital, Nijmegen, Netherlands
| | - Arend F. Bos
- Department of Neonatology, University Medical Center Groningen, University of Groningen, Beatrix Children's Hospital, Groningen, Netherlands
| | - Frank L. M. Delbressine
- Department of Industrial Design Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Alex J. Eggink
- Department of Obstetrics and Gynecology, Erasmus Medical Centre, Rotterdam, Netherlands
| | - Jan Jaap H. M. Erwich
- Department of Obstetrics and Gynecology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Loe M. G. Feijs
- Department of Industrial Design Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Floris Groenendaal
- Department of Neonatology, Utrecht University Medical Center, Utrecht, Netherlands
| | - Boris W. W. Kramer
- Department of Neonatology, Maastricht University Medical Center (MUMC), Maastricht, Netherlands
| | - A. Titia Lely
- Department of Obstetrics and Gynecology, Utrecht University Medical Center, Utrecht, Netherlands
| | - Rachel F. A. M. Loop
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Department of Industrial Design Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Franziska Neukamp
- Institute for Applied Medical Engineering and Clinic for Neonatology, University Hospital Aachen, Aachen, Germany
| | - Wes Onland
- Department of Neonatology, Amsterdam UMC, Amsterdam, Netherlands
| | - Martijn A. Oudijk
- Amsterdam Reproduction and Development Research Institute, Department of Obstetrics, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Arjan B. te Pas
- Department of Neonatology, Leiden University Medical Center (LUMC), Leiden, Netherlands
| | - Irwin K. M. Reiss
- Department of Neonatology, Erasmus Medical Centre, Rotterdam, Netherlands
| | - Mark Schoberer
- Institute for Applied Medical Engineering and Clinic for Neonatology, University Hospital Aachen, Aachen, Germany
| | - Ralph R. Scholten
- Department of Obstetrics and Gynecology, Radboud Medical Centre, Nijmegen, Netherlands
| | - Marc E. A. Spaanderman
- Department of Obstetrics and Gynecology, Radboud Medical Centre, Nijmegen, Netherlands
- Department of Obstetrics and Gynecology, Maastricht University Medical Center (MUMC), Maastricht, Netherlands
| | - Myrthe van der Ven
- Department of Obstetrics and Gynecology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Marijn J. Vermeulen
- Department of Neonatology, Erasmus Medical Centre, Rotterdam, Netherlands
- Care4Neo Foundation, Rotterdam, Netherlands
| | - Frans N. van de Vosse
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - S. Guid Oei
- Department of Obstetrics and Gynecology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| |
Collapse
|
4
|
Segers S. The path toward ectogenesis: looking beyond the technical challenges. BMC Med Ethics 2021; 22:59. [PMID: 33985480 PMCID: PMC8120724 DOI: 10.1186/s12910-021-00630-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Accepted: 05/07/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Breakthroughs in animal studies make the topic of human application of ectogenesis for medical and non-medical purposes more relevant than ever before. While current data do not yet demonstrate a reasonable expectation of clinical benefit soon, several groups are investigating the feasibility of artificial uteri for extracorporeal human gestation. MAIN TEXT This paper offers the first comprehensive and up to date discussion of the most important pros and cons of human ectogenesis in light of clinical application, along with an examination of crucial ethical (and legal) issues that continued research into, and the clinical translation of, ectogenesis gives rise to. The expected benefits include advancing prenatal medicine, improving neonatal intensive care, and providing a novel pathway towards biological parenthood. This comes with important future challenges. Prior to human application, important questions have to be considered concerning translational research, experimental use of human fetuses and appropriate safety testing. Key questions are identified regarding risks to ectogenesis' subjects, and the physical impact on the pregnant person when transfer from the uterus to the artificial womb is required. Critical issues concerning proportionality have to be considered, also in terms of equity of access, relative to the envisaged application of ectogenesis. The advent of ectogenesis also comes with crucial issues surrounding abortion, extended fetal viability and moral status of the fetus. CONCLUSIONS The development of human ectogenesis will have numerous implications for clinical practice. Prior to human testing, close consideration should be given to whether (and how) ectogenesis can be introduced as a continuation of existing neonatal care, with due attention to both safety risks to the fetus and pressures on pregnant persons to undergo experimental and/or invasive procedures. Equally important is the societal debate about the acceptable applications of ectogenesis and how access to these usages should be prioritized. It should be anticipated that clinical availability of ectogenesis, possibly first as a way to save extremely premature fetuses, may spark demand for non-medical purposes, like avoiding physical and social burdens of pregnancy.
Collapse
Affiliation(s)
- Seppe Segers
- Department of Philosophy and Moral Sciences, Bioethics Institute Ghent, Ghent University, Blandijnberg 2, 9000, Ghent, Belgium.
| |
Collapse
|
5
|
Didier RA, Sridharan A, Lawrence K, Coleman BG, Davey MG, Flake AW. Contrast-Enhanced Ultrasound in Extracorporeal Support: In Vitro Studies and Initial Experience and Safety Data in the Extreme Premature Fetal Lamb Maintained by the Extrauterine Environment for Neonatal Development. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:1971-1978. [PMID: 30560564 DOI: 10.1002/jum.14885] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 10/16/2018] [Indexed: 06/09/2023]
Abstract
OBJECTIVES To evaluate the effects of ultrasound contrast agent (UCA) administration on hemodynamic parameters and support equipment in in vitro and in vivo models of extracorporeal support. METHODS In vitro, incrementally increasing bolus doses of a UCA were administered proximal to a membrane oxygenator, and ultrasound cine clips were obtained. The rates of microbubble destruction across the oxygenator and over time were calculated from time-intensity-curves. Measurements across the membrane oxygenator were recorded and compared by a repeated-measures analysis of variance. In vivo, 7 premature fetal lambs were transferred from placental support to the extrauterine environment for neonatal development. Contrast agent boluses were administered for contrast-enhanced ultrasound (CEUS) examinations. Hemodynamic parameters and serum laboratory values were evaluated before and after the examinations by paired t tests. For oxygenator staining, oxygenator membranes from the in vitro circuit, study animals (n = 4), and control animals (n = 4) were stained for the adherent UCA. RESULTS In vitro, with all doses (0.1-4 mL), there was no difference in measured parameters across the oxygenator (P ≥ .09). Contrast agent destruction (3%-14%) across the oxygenator was observed at the first pass with a progressive decline in contrast intensity over time. In vivo, there was no difference in hemodynamic parameters or serum laboratory values (P ≥ .08) with any CEUS examination (n = 17). For oxygenator staining, all oxygenator membranes were negative for UCA with lipid staining. CONCLUSIONS The UCA had no detectable effect on the oxygenator or measured parameters in in vitro and in vivo studies, thus providing additional safety data to support the use of CEUS in the setting of extracorporeal support.
Collapse
Affiliation(s)
- Ryne A Didier
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Anush Sridharan
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Kendall Lawrence
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Surgery, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Center for Fetal Research, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Beverly G Coleman
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Marcus G Davey
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Surgery, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Center for Fetal Research, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| | - Alan W Flake
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Surgery, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Center for Fetal Research, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
| |
Collapse
|
6
|
McLeod JS, Church JT, Yerramilli P, Coughlin MA, Perkins EM, Rabah R, Bartlett RH, Rojas-Pena A, Greenson JK, Perrone EE, Mychaliska GB. Gastrointestinal mucosal development and injury in premature lambs supported by the artificial placenta. J Pediatr Surg 2018; 53:1240-1245. [PMID: 29605266 PMCID: PMC5994371 DOI: 10.1016/j.jpedsurg.2018.02.092] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Accepted: 02/27/2018] [Indexed: 01/19/2023]
Abstract
BACKGROUND An Artificial Placenta (AP) utilizing extracorporeal life support (ECLS) could revolutionize care of extremely premature newborns, but its effects on gastrointestinal morphology and injury need investigation. METHODS Lambs (116-121days GA, term=145; n=5) were delivered by C-section, cannulated for ECLS, had total parenteral nutrition (TPN) provided, and were supported for 7days before euthanasia. Early and Late Tissue Controls (ETC, n=5 and LTC, n=5) delivered at 115-121days and 125-131days, respectively, were immediately sacrificed. Standardized jejunal samples were formalin-fixed for histology. Crypt depth (CD), villus height (VH), and VH:CD ratios were measured. Measurements also included enterocyte proliferation (Ki-67), Paneth cell count (Lysozyme), and injury scores (H&E). ANOVA and Chi Square were used with p<0.05 considered significant. RESULTS CD, VH, and VH:CD were similar between groups (p>0.05). AP demonstrated more enterocyte proliferation (95.7±21.8) than ETC (49.4±23.4; p=0.003) and LTC (66.1+11.8; p=0.04), and more Paneth cells (81.7±17.5) than ETC (41.6±7.0; p=0.0005) and LTC (40.7±8.2, p=0.0004). Presence of epithelial injury and congestion in the bowel of all groups were not statistically different. No villus atrophy or inflammation was present in any group. CONCLUSIONS This suggests preserved small bowel mucosal architecture, high cellular turnover, and minimal evidence of injury. STUDY TYPE Research paper/therapeutic potential. LEVEL OF EVIDENCE N/A.
Collapse
Affiliation(s)
- Jennifer S McLeod
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI.
| | - Joseph T Church
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI
| | - Prathusha Yerramilli
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI
| | - Megan A Coughlin
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI
| | - Elena M Perkins
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI
| | - Raja Rabah
- Department of Pathology, Michigan Medicine, Ann Arbor, MI
| | - Robert H Bartlett
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI
| | - Alvaro Rojas-Pena
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI
| | - Joel K Greenson
- Department of Gastrointestinal Pathology, Michigan Medicine, Ann Arbor, MI
| | - Erin E Perrone
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI; Fetal Diagnosis and Treatment Center, C.S. Mott Children's Hospital, Michigan Medicine, Ann Arbor, MI
| | - George B Mychaliska
- Extracorporeal Life Support Laboratory, Department of Surgery, Michigan Medicine, Ann Arbor, MI; Fetal Diagnosis and Treatment Center, C.S. Mott Children's Hospital, Michigan Medicine, Ann Arbor, MI
| |
Collapse
|
7
|
Partridge EA, Davey MG, Hornick MA, McGovern PE, Mejaddam AY, Vrecenak JD, Mesas-Burgos C, Olive A, Caskey RC, Weiland TR, Han J, Schupper AJ, Connelly JT, Dysart KC, Rychik J, Hedrick HL, Peranteau WH, Flake AW. An extra-uterine system to physiologically support the extreme premature lamb. Nat Commun 2017; 8:15112. [PMID: 28440792 PMCID: PMC5414058 DOI: 10.1038/ncomms15112] [Citation(s) in RCA: 153] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Accepted: 03/02/2017] [Indexed: 12/18/2022] Open
Abstract
In the developed world, extreme prematurity is the leading cause of neonatal mortality and morbidity due to a combination of organ immaturity and iatrogenic injury. Until now, efforts to extend gestation using extracorporeal systems have achieved limited success. Here we report the development of a system that incorporates a pumpless oxygenator circuit connected to the fetus of a lamb via an umbilical cord interface that is maintained within a closed 'amniotic fluid' circuit that closely reproduces the environment of the womb. We show that fetal lambs that are developmentally equivalent to the extreme premature human infant can be physiologically supported in this extra-uterine device for up to 4 weeks. Lambs on support maintain stable haemodynamics, have normal blood gas and oxygenation parameters and maintain patency of the fetal circulation. With appropriate nutritional support, lambs on the system demonstrate normal somatic growth, lung maturation and brain growth and myelination.
Collapse
Affiliation(s)
- Emily A Partridge
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Marcus G Davey
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Matthew A Hornick
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Patrick E McGovern
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Ali Y Mejaddam
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Jesse D Vrecenak
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Carmen Mesas-Burgos
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Aliza Olive
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Robert C Caskey
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Theodore R Weiland
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Jiancheng Han
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Alexander J Schupper
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - James T Connelly
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Kevin C Dysart
- Division of Neonatology, Department of Pediatrics, The Children's Hospital of Philadelphia, 3401 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Jack Rychik
- Division of Cardiology, Department of Pediatrics, The Children's Hospital of Philadelphia, 3401 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Holly L Hedrick
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - William H Peranteau
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| | - Alan W Flake
- Center for Fetal Research, Department of Surgery, The Children's Hospital of Philadelphia Research Institute, Room 1116B, 3615 Civic Center Boulevard, Philadelphia, Pennsylvania 19104, USA
| |
Collapse
|
8
|
Bird SD. Artificial placenta: Analysis of recent progress. Eur J Obstet Gynecol Reprod Biol 2016; 208:61-70. [PMID: 27894031 DOI: 10.1016/j.ejogrb.2016.11.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Revised: 10/18/2016] [Accepted: 11/10/2016] [Indexed: 12/18/2022]
Abstract
The artificial placenta (AP) has for many decades captured the imagination of scientists and authors with popular fiction including The Matrix and Aldous Huxley's "Brave New World", depicting a human surviving ex-utero in an artificial uterine environment (AUE). For scientists this has fascinated as a way forward for extremely preterm infants (EPIs) born less than 28 weeks of gestation. Early successes with mechanical ventilation (MV) for infants born above 28 weeks of gestation meant that AP research lost momentum. More recently, the gestational age limit for survival now borders on 23 weeks and corresponds to the biological milestone of lung development marked by the early canalicular stage of lung morphogenesis. The so called greyzone of 23-25 weeks represents a steep increase in mortality with decreasing gestational age and current options in neonatal care are on the fringes of efficacy for this population. A shift in thinking recognizes the vitality of EPIs as a fetus rather than a 37-40 week neonate and this has reinvigorated the concept of the AP. This review will discuss the scale of extreme preterm birth with special reference to previable infants born in the greyzone. Recent AP studies using sheep models are compared, technical obstacles discussed and future research themes identified.
Collapse
Affiliation(s)
- Stephen D Bird
- Department of Obstetrics and Gynaecology, The University of Melbourne, Australia.
| |
Collapse
|
9
|
Metelo-Coimbra C, Roncon-Albuquerque R. Artificial placenta: Recent advances and potential clinical applications. Pediatr Pulmonol 2016; 51:643-9. [PMID: 26915478 DOI: 10.1002/ppul.23401] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2015] [Revised: 12/02/2015] [Accepted: 01/21/2016] [Indexed: 12/12/2022]
Abstract
Lung immaturity remains a major cause of morbidity and mortality in extremely premature infants. Positive-pressure mechanical ventilation, the method of choice for respiratory support in premature infants, frequently promotes by itself lung injury and a negative impact in the circulatory function. Extracorporeal lung support has been proposed for more than 50 years as a potential alternative to mechanical ventilation in the treatment of severe respiratory failure of extremely premature infants. Recent advances in this field included the development of miniaturized centrifugal pumps and polymethylpentene oxygenators, as well as the successful use of pump-assisted veno-venous extracorporeal gas exchange systems in experimental artificial placenta models. This review, which includes studies published from 1958 to 2015, presents an update on the artificial placenta concept and its potential clinical applications. Special focus will be devoted to the milestones achieved so far and to the limitations that must be overcome before its clinical application. Notwithstanding, the artificial placenta stands as a promising alternative to mechanical ventilation in extremely premature infants. Pediatr Pulmonol. 2016;51:643-649. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Catarina Metelo-Coimbra
- Department of Physiology and Cardiothoracic Surgery, Faculty of Medicine of Porto, Porto, Portugal
| | - Roberto Roncon-Albuquerque
- Department of Physiology and Cardiothoracic Surgery, Faculty of Medicine of Porto, Porto, Portugal.,Department of Emergency and Intensive Care Medicine, Hospital de S.João, Porto, Portugal
| |
Collapse
|
10
|
Bratlid D. [Premature babies and treatment limits - ethics and priorities]. TIDSSKRIFT FOR DEN NORSKE LEGEFORENING 2016; 136:518-9. [PMID: 27052908 DOI: 10.4045/tidsskr.16.0146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
|