1
|
Arvind A, Nanjappa R, Gupta KK, Macedo-de-Araújo RJ, Fadel D. Lid wiper epitheliopathy: Topical review of current identification strategies and future perspectives. Cont Lens Anterior Eye 2024:102312. [PMID: 39317557 DOI: 10.1016/j.clae.2024.102312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 08/13/2024] [Accepted: 09/14/2024] [Indexed: 09/26/2024]
Abstract
Lid Wiper Epitheliopathy (LWE) is a recognized ocular condition affecting visual quality and ocular comfort, characterized by the damage of the marginal conjunctiva of the upper eyelid. This review critically examines the current strategies for LWE identification and explores the multifactorial etiology of LWE and its association with various ocular surface diseases. A literature review conducted on PubMed identified 67 relevant studies, which were analyzed to enhance understanding of LWE's diagnostic criteria and its clinical implications, offering future perspectives on improving diagnostic accuracy and patient outcomes. The association between LWE and contact lens-related discomfort is examined, with studies reporting conflicting findings regarding its prevalence and severity among soft contact lens wearers. Moreover, LWE has been linked to tear film abnormalities, altered tear composition, and eyelid margin abnormalities in non-contact lens wearers, further complicating diagnosis and management. Current LWE grading systems, including subjective methods and semi-objective approaches, are reviewed, highlighting challenges such as subjectivity, complexity, and variability. Recent advances in LWE grading, including semi-automated methods and photographic scales, show promise but face implementation challenges in clinical settings. The review concludes by proposing areas for further research, including investigating factors contributing to LWE onset and development, developing more sensitive diagnostic tools, and exploring the impact of LWE on ocular surface health and visual function. Standardization, validation, and innovation in grading systems are emphasized to enhance diagnostic accuracy and improve clinical outcomes for patients with LWE. Ongoing research in LWE grading is essential for addressing diagnostic challenges and optimizing assessment methodologies in clinical practice.
Collapse
Affiliation(s)
- Anitha Arvind
- Department of Optometry, School of Healthcare and Allied Sciences, GD Goenka University, Gurugram, India.
| | - Rakesh Nanjappa
- Department of Optometry, School of Healthcare and Allied Sciences, GD Goenka University, Gurugram, India
| | - Krishna Kumar Gupta
- Department of Optometry, School of Healthcare and Allied Sciences, GD Goenka University, Gurugram, India
| | - Rute J Macedo-de-Araújo
- Clinical & Experimental Optometry Research Lab (CEORLab), Center of Physics, University of Minho, Braga, Portugal; Physics Center of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, Portugal
| | - Daddi Fadel
- Center for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| |
Collapse
|
2
|
Huang M, Yan X, Gao Y, Song W, Cheng Y, Xie L, Li Y, Zhou X, Yang S. The effect of type 2 diabetes mellitus on lid wiper epitheliopathy and ocular surface parameters. Heliyon 2024; 10:e36912. [PMID: 39281498 PMCID: PMC11402120 DOI: 10.1016/j.heliyon.2024.e36912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 08/09/2024] [Accepted: 08/23/2024] [Indexed: 09/18/2024] Open
Abstract
Introduction This cross-sectional study was conducted to investigate the impact of type 2 diabetes mellitus(DM) and its duration on indicators such as lid wiper epitheliopathy(LWE), and to assess the significance of LWE for early diagnosis of dry eye disease(DED) in DM patients. Methods A total of 137 subjects with ocular surface disease index(OSDI) score ≥13 were divided into the non-DM group, the short-term DM group (duration <5 years), and the mid-to-long-term DM group(duration ≥5 years). Evaluations were conducted for LWE, OSDI, lipid layer thickness (LLT), partial blinking rate (PBR), fluorescein tear breakup time (FTBUT), corneal fluorescein staining score (CFS), eyelid margin score, and meibomian gland dropout (MGd). Results The upper-LWE score and total LWE score in the mid-to-long-term group were higher than those in the non-DM group (p = 0.008 and p = 0.031, respectively). The lower-LWE scores were more severe than upper-LWE scores in the non-DM and short-term groups (p = 0.001 and p = 0.045, respectively).The confirmed diagnosis rate of DEWSII dry eye with LWE as the primary diagnostic indicator was significantly higher than that which utilize FTBUT<5s as the primary diagnostic indicator(p < 0.05). Compared to the non-DM group, the LLT was thinner and the MGd was more severe in the mid-to long-term group. The upper-LWE score was moderately positively correlated with the MGd, and the lower LWE score was moderately negatively correlated with LLT. Conclusion LWE, LLT, and MGd worsen with the progression of diabetes. Additionally, changes in LWE may precede the FTBUT, indicating that LWE could be considered as an important indicator for early diagnosis of DED in diabetic patients.
Collapse
Affiliation(s)
- Meiting Huang
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Xiaoming Yan
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Yuan Gao
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Wenjing Song
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Yu Cheng
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Luoying Xie
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Yingsi Li
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Xuecong Zhou
- Peking University First Hospital, Xicheng District, Beijing, China
| | - Songlin Yang
- Peking University First Hospital, Xicheng District, Beijing, China
| |
Collapse
|
3
|
Kim B, Lee Y, Son HS, Choi CY. Clinical outcomes of conjunctivochalasis treatment with a new ophthalmic radiofrequency device. BMC Ophthalmol 2024; 24:302. [PMID: 39039541 PMCID: PMC11265150 DOI: 10.1186/s12886-024-03499-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2023] [Accepted: 05/27/2024] [Indexed: 07/24/2024] Open
Abstract
PURPOSE To investigate the safety and efficacy of a new micro-controlled radiofrequency device for treatment of conjunctivochalasis (Cch). METHODS Data of 127 patients (230 eyes) who underwent ophthalmic radiofrequency treatment for Cch from January 2020 to June 2023 were analyzed retrospectively. Cch coagulation was performed with a radiofrequency electrode tip (OcuRF®, Ilooda, Korea) and a high-frequency radio-wave electric unit (0.6 ~ 0.8 watts, 2 MHz, Acutron™, Ilooda, Korea). Pre- and postoperative Cch grading, slit-lamp photography, tear film break-up time (TBUT), and bulbar conjunctival hyperemia using Keratograph 5 M (Oculus, Wetzlar, Germany) were evaluated. Cch grade 0 or 1 after surgery was regarded as 'success'. Complications, recurrence, and additional treatment rates were analyzed. RESULTS In 227 (98.7%) eyes, the radiofrequency treatment led to marked improvement of Cch, with 224 (97.4%) eyes achieving grade 0 or 1 at 2 months postoperatively. Eight eyes (3.5%) received additional treatment. TBUT improved from 3.17 ± 0.82 s to 5.28 ± 1.10 s after surgery (P < 0.001). The total bulbar conjunctival hyperemia value showed an improvement from 1.7 ± 0.6 to 1.4 ± 0.6 postoperatively (P < 0.05). No serious complications were observed. CONCLUSION The novel ophthalmic radiofrequency device led to a marked improvement of Cch with no serious adverse events during the entire follow-up period. Our results suggest that the radiofrequency device presents a safe and efficacious treatment option for Cch.
Collapse
Affiliation(s)
- Bokyung Kim
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Yongwoo Lee
- Department of Ophthalmology, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Republic of Korea
| | - Hyeck-Soo Son
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
| |
Collapse
|
4
|
Wang MTM, Power B, Xue AL, Craig JP. Discriminative performance of ocular surface staining and lid wiper epitheliopathy in dry eye disease: An investigator-masked, prospective registry-based, diagnostic accuracy study. Ocul Surf 2024; 34:165-172. [PMID: 39038751 DOI: 10.1016/j.jtos.2024.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 07/16/2024] [Accepted: 07/19/2024] [Indexed: 07/24/2024]
Abstract
PURPOSE To evaluate the diagnostic performance of corneal and conjunctival staining, and lid wiper epitheliopathy (LWE) in detecting dry eye disease, as defined by the global consensus Tear Film and Ocular Surface Society Dry Eye Workshop II (TFOS DEWS II) criteria. METHODS A total of 2066 community residents (1285 females; mean ± SD age, 40 ± 19 years) were recruited in an investigator-masked, prospective registry-based, diagnostic accuracy study. Dry eye symptomology and ocular surface parameters were assessed in a single clinical session. The Sjögren's International Collaborative Clinical Alliance (SICCA) corneal and conjunctival staining scoring and Korb lid wiper epitheliopathy (LWE) grading were evaluated by an independent masked assessor. RESULTS Overall, 807 (39 %) participants fulfilled the TFOS DEWS II criteria for dry eye disease, of which 178 (9 %) participants were classified as moderate-to-severe disease. The discriminative abilities of superior and inferior LWE (C-statistics, 0.724 and 0.712, respectively) were greater than corneal and conjunctival staining (C-statistics, 0.573 and 0.627, respectively). The Youden-optimal diagnostic cut-offs for the SICCA corneal and conjunctival staining scores were both ≥1, and the optimal thresholds for the Korb superior and inferior LWE grades were both ≥1. LWE was more commonly detected in both mild-to-moderate and moderate-to-severe dry eye disease, and demonstrated more consistent correlation with other ocular surface parameters across a broader range of disease severity. CONCLUSIONS LWE demonstrates superior diagnostic performance relative to corneal and conjunctival staining. These findings would support the routine incorporation of LWE evaluation as part of the diagnostic workup of dry eye disease.
Collapse
Affiliation(s)
- Michael T M Wang
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Barry Power
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, New Zealand; Department of Ophthalmology, Royal Victoria Eye and Ear Hospital, Dublin, Ireland
| | - Ally L Xue
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Jennifer P Craig
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, New Zealand.
| |
Collapse
|
5
|
Ballesteros-Sánchez A, Sánchez-González JM, Borrone MA, Borroni D, Rocha-de-Lossada C. The Influence of Lid-Parallel Conjunctival Folds and Conjunctivochalasis on Dry Eye Symptoms with and Without Contact Lens Wear: A Review of the Literature. Ophthalmol Ther 2024; 13:651-670. [PMID: 38217793 PMCID: PMC10853109 DOI: 10.1007/s40123-023-00877-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 12/18/2023] [Indexed: 01/15/2024] Open
Abstract
INTRODUCTION Lid-parallel conjunctival folds (LIPCOF) and conjunctivochalasis (CCH) are similar conditions that seem to be related to dry eye severity. In addition, there is a lack of studies on the topic of LIPCOF and CCH on dry eye symptoms in non-contact lens and contact lens (CL) wearers. Therefore, the aim of this study is to review the relationship of LIPCOF and CCH with dry eye symptoms in non-CL and CL wearers, as well as to report the treatment of dry eye disease (DED) in non-CL and CL wearers who present LIPCOF or CCH. METHODS A literature review of full-length original studies in two databases, PubMed and Scopus, was performed. The search period included observational studies in humans published between April 21, 2009 and March 20, 2023. RESULTS A total of 26 studies were included. The studies suggest that LIPCOF and CCH are significantly related to dry eye symptoms in non-CL and CL wearers. However, the impact of CL wear on LIPCOF and CCH may be complex and may vary depending on individual factors such as lens type, lens care regimen, and pre-existing ocular conditions. Regarding LIPCOF management, tear substitutes seem to significantly reduce LIPCOF and dry eye symptoms in non-CL wearers, while vectored thermal pulsation (VTP) and microblepharoexfoliation (MBE) are suggested as promising treatment for LIPCOF and dry eye symptoms in CL wearers. Regarding CCH management, surgical interventions may be effective in reducing CCH when medical treatments have no response. In addition, an ocular examination by slit lamp is necessary to distinguish both conditions. CONCLUSIONS Tear substitutes, VTP, MBE, and fitting CLs with low coefficient of friction (CoF) seem to reduce and prevent LIPCOF. However, surgical treatment options seem to be more effective in the complete elimination of CCH. An adequate evaluation and differentiation between LIPCOF and CCH are important, and they should be considered by practitioners in managing dry eye symptoms in non-CL and CL wearers.
Collapse
Affiliation(s)
- Antonio Ballesteros-Sánchez
- Department of Physics of Condensed Matter, Optics Area, University of Seville, Reina Mercedes Street, Seville, Spain.
- Department of Ophthalmology, Clínica Novovisión, Murcia, Spain.
| | - José-María Sánchez-González
- Department of Physics of Condensed Matter, Optics Area, University of Seville, Reina Mercedes Street, Seville, Spain
| | - María Agustina Borrone
- Department of Ophthalmology, Hospital General de Agudos Dr Ignacio Pirovano, Buenos Aires, Argentina
| | - Davide Borroni
- Department of Doctoral Studies, Riga Stradins University, Riga, 1007, Latvia
- Advalia Vision, Cornea Research Unit, 20145, Milan, Italy
| | - Carlos Rocha-de-Lossada
- Qvision, Ophthalmology Department, VITHAS Almeria Hospital, 04120, Almeria, Spain
- Ophthalmology Department, VITHAS Malaga, 29016, Malaga, Spain
- Regional University Hospital of Malaga, Hospital Civil Square, 29009, Malaga, Spain
- Surgery Department, Ophthalmology Area, University of Seville, Doctor Fedriani, 41009, Seville, Spain
| |
Collapse
|
6
|
Ravikumar A, Queener HM, Osae EA, Ritchey ER. A Hue-Value method for semi-automated assessment of Lid Wiper Epitheliopathy. Cont Lens Anterior Eye 2024; 47:102090. [PMID: 37977904 DOI: 10.1016/j.clae.2023.102090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 10/24/2023] [Accepted: 11/03/2023] [Indexed: 11/19/2023]
Abstract
BACKGROUND Lid wiper epitheliopathy (LWE) is a marker of an abnormal lid/cornea interaction. This study proposes an automated Hue-Value grading algorithm of LWE staining following manual selection of the region of interest. METHODS Images of LWE staining were processed using Hue and Value from HSV (Hue-Saturation-Value) color space with a custom MATLAB program. Thirty-one images were successfully analyzed. Examiners analyzed images in random order twice, separated by more than a week. Bland Altman and Intraclass Correlation Coefficients (ICC) were performed. RESULTS There was no difference (p > 0.05) between upper (UL) and lower (LL) eyelids for LWE height (UL: 0.12 ± 0.12 mm, LL: 0.12 ± 0.07 mm), width (UL: 10.70 ± 3.84 mm, LL: 10.26 ± 3.49 mm), or area (UL: 2.85 ± 2.67 mm2, LL: 2.63 ± 1.71 mm2). There was no between examiner difference for all eyelid LWE height or area (p > 0.05), but a difference in LWE width (0.16 mm; p = 0.031). ICC for LWE height, width and area were 0.996 (95% CI: 0.993 to 0.998), 0.997 (95% CI: 0.992 to 0.998) and 0.999 (95% CI: 0.998 to 0.999). There was no between examiner difference for height or area (p > 0.05) for UL, but a difference in LWE width (0.28 mm; p = 0.026). ICC for height, width and area were 0.999 (95% CI: 0.996 to 1.00), 0.995 (95% CI: 0.982 to 0.999) and 1.00 (95% CI: 0.999 to 1.00). There was no difference in LWE height, width or area for LL (all p > 0.05). ICC were 0.991 (95% CI: 0.973 to 0.997) for height, 0.998 (95% CI: 0.995 to 0.999) for width and 0.997 (95% CI: 0.990 to 0.999) for area. CONCLUSIONS This novel method results in highly repeatable interexaminer measures of LWE staining after general lid region delineation. Small differences in LWE width were observed between examiners.
Collapse
Affiliation(s)
| | - Hope M Queener
- The University of Houston College of Optometry, Houston, TX, USA
| | - Eugene A Osae
- The University of Houston College of Optometry, Houston, TX, USA
| | - Eric R Ritchey
- The University of Houston College of Optometry, Houston, TX, USA.
| |
Collapse
|
7
|
Valencia-Nieto L, López-de la Rosa A, López-Miguel A, González-García MJ. Clinical characterisation of contact lens discomfort progression. Cont Lens Anterior Eye 2024; 47:102096. [PMID: 38097423 DOI: 10.1016/j.clae.2023.102096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 10/15/2023] [Accepted: 11/27/2023] [Indexed: 01/22/2024]
Abstract
PURPOSE This study aimed to assess the subjective and objective differences among the steps of the contact lens discomfort (CLD) progression classification established by the Tear Film & Ocular Surface Society (TFOS) using questionnaires and clinical signs, and to propose a simplified classification. METHODS Contact lens (CL) wearers were evaluated in a single visit. The Contact Lens Dry Eye Questionnaire (CLDEQ)-8, the Contact Lens Discomfort Index, and Visual Analog Scales for discomfort and dryness were administered. The non-invasive break-up time, the tear film lipid layer thickness, conjunctival hyperaemia and papillae, lid-parallel conjunctival folds, the fluorescein tear film break-up time, corneal and conjunctival staining, lid wiper epitheliopathy, and the Schirmer test were assessed. Sign and symptom scores were compared among TFOS CLD progression steps using analysis of variance or the Kruskal-Wallis H test. Steps 1 and 2 (reduced comfort), and steps 3 and 4 (reduced wearing time) of the TFOS classification were combined to obtain a simplified classification, and the same comparison was performed. A p-value ≤ 0.05 was considered statistically significant. RESULTS One hundred-fifty CL wearers (97 women and 53 men) aged 34.4 ± 12.6 years were included. In the TFOS classification, there were significant differences between step 0 (no CLD) and the rest of the severity steps for the scores obtained in all questionnaires (p ≤ 0.015). All steps were differentiated (p ≤ 0.032) based on the simplified classification for all questionnaires, except steps 1 and 2 for the CLDEQ-8 and dryness VAS (p = 0.089 and p = 0.051, respectively). There were no differences (all p ≥ 0.06) between the sign scores among the steps of either classification. CONCLUSION CLD management is encouraged from its first appearance. Simplifying the phases of CLD severity may allow a more accurate classification and a better awareness of the problem by clinicians and CL wearers by using more straightforward simple messages.
Collapse
Affiliation(s)
- Laura Valencia-Nieto
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain
| | - Alberto López-de la Rosa
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, University of Valladolid, Valladolid, Spain.
| | - María J González-García
- Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
8
|
Martinez-Carrasco R, Rachagani S, Batra SK, Argüeso P, Fini ME. Roles unveiled for membrane-associated mucins at the ocular surface using a Muc4 knockout mouse model. Sci Rep 2023; 13:13558. [PMID: 37604830 PMCID: PMC10442421 DOI: 10.1038/s41598-023-40491-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 08/11/2023] [Indexed: 08/23/2023] Open
Abstract
Membrane-associated mucins (MAMs) are proposed to play critical roles at the ocular surface; however, in vivo evidence has been lacking. Here we investigate these roles by phenotyping of a Muc4 KO mouse. Histochemical analysis for expression of the beta-galactosidase transgene replacing Muc4 revealed a spiraling ribbon pattern across the corneal epithelium, consistent with centripetal cell migration from the limbus. Depletion of Muc4 compromised transcellular barrier function, as evidenced by an increase in rose bengal staining. In addition, the corneal surface was less smooth, consistent with disruption of tear film stability. While surface cells presented with well-developed microprojections, an increase in the number of cells with fewer microprojections was observed. Moreover, an increase in skin-type keratin K10 and a decrease in transcription factor Pax6 was observed, suggesting an incipient transdifferentiation. Despite this, no evidence of inflammatory dry eye disease was apparent. In addition, Muc4 had no effect on signaling by toll-like receptor Tlr4, unlike reports for MUC1 and MUC16. Results of this study provide the first in vivo evidence for the role of MAMs in transcellular barrier function, tear film stability, apical epithelial cell architecture, and epithelial mucosal differentiation at the ocular surface.
Collapse
Affiliation(s)
- Rafael Martinez-Carrasco
- New England Eye Center, Tufts Medical Center and Department of Ophthalmology, Tufts University School of Medicine, Boston, MA, 02111, USA
| | - Satyanarayan Rachagani
- Department of Biochemistry & Molecular Biology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Surinder K Batra
- Department of Biochemistry & Molecular Biology, University of Nebraska Medical Center, Omaha, NE, USA
- Department of Pathology, University of Nebraska Medical Center, Omaha, NE, USA
- Buffett Cancer Center, Eppley Institute for Research in Cancer and Allied Diseases, University of Nebraska Medical Center, Omaha, NE, USA
| | - Pablo Argüeso
- New England Eye Center, Tufts Medical Center and Department of Ophthalmology, Tufts University School of Medicine, Boston, MA, 02111, USA
- Program in Immunology, Tufts Graduate School of Biomedical Sciences, Tufts University, Boston, MA, USA
- Program in Genetics, Molecular & Cellular Biology, Tufts Graduate School of Biomedical Sciences, Tufts University, Boston, MA, USA
- Program in Pharmacology & Drug Development, Tufts Graduate School of Biomedical Sciences, Tufts University, Boston, MA, USA
| | - M Elizabeth Fini
- New England Eye Center, Tufts Medical Center and Department of Ophthalmology, Tufts University School of Medicine, Boston, MA, 02111, USA.
- Program in Genetics, Molecular & Cellular Biology, Tufts Graduate School of Biomedical Sciences, Tufts University, Boston, MA, USA.
- Program in Pharmacology & Drug Development, Tufts Graduate School of Biomedical Sciences, Tufts University, Boston, MA, USA.
| |
Collapse
|
9
|
Oganov A, Yazdanpanah G, Jabbehdari S, Belamkar A, Pflugfelder S. Dry eye disease and blinking behaviors: A narrative review of methodologies for measuring blink dynamics and inducing blink response. Ocul Surf 2023; 29:166-174. [PMID: 37257694 DOI: 10.1016/j.jtos.2023.05.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 04/28/2023] [Accepted: 05/28/2023] [Indexed: 06/02/2023]
Abstract
Dry eye disease (DED) is a leading cause of ophthalmology clinical encounters with prevalence ranging from 8.7% to 64% in various populations. Blinking is an endogenous process to refresh the tear film, clear debris and maintain quality vision. Altered blinking behavior is a common feature of DED and is implicated in the pathology of the disease. However, lack of a comprehensive review on the relationship between altered blinking behavior and DED is notable in the literature. Blinking behavior may be an effect of DED due to an unstable tear film sensitizing a motor response or be its cause due to destabilization of the tear film in conditions such as benign essential blepharospasm. In this comprehensive review, we summarize the current models and theories of tear film dynamics and blinking behavior to better understand their connection to DED and introduce contemporary technologies and measurement tools used in the evaluation and induction of blinking behavior. We also describe future directions of research to better understand the relationship between DED and blinking and explore therapies that address the abnormal blinking component of DED.
Collapse
Affiliation(s)
- Anthony Oganov
- Department of Ophthalmology, Renaissance School of Medicine, Stony Brook, NY, USA
| | - Ghasem Yazdanpanah
- Illinois Eye and Ear Infirmary, Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Illinois, USA
| | - Sayena Jabbehdari
- Jones Eye Institute, University of Arkansas for Medical Sciences, Arkansas, USA
| | - Aditya Belamkar
- Indiana University School of Medicine, Indianapolis, IN, USA
| | | |
Collapse
|
10
|
Itah S, Elad D, Jaffa AJ, Grisaru D, Rosner M. Transmembrane Mucin Response in Conjunctival Epithelial Cells Exposed to Wall Shear Stresses. Int J Mol Sci 2023; 24:ijms24076589. [PMID: 37047561 PMCID: PMC10095083 DOI: 10.3390/ijms24076589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/08/2023] [Accepted: 03/20/2023] [Indexed: 04/05/2023] Open
Abstract
Human conjunctival epithelium cells (HCEC) line the inner surface of the eyelid and cover the sclera and are continuously subjected to wall shear stresses (WSS). The effects of external forces on the conjunctival epithelium are not fully known. The conjunctival epithelium contains stratified squamous cells that synthesize the membrane-spanning mucins MUC1 and MUC16, which play important roles in protecting the ocular surface. Alterations in both gel-forming and membrane-tethered mucins occur in drying ocular surface diseases. The aim of this study was to explore the mechanobiological characteristics of transmembrane mucin secretion and cellular alterations of primary HCEC exposed to airflow-induced WSS perturbations. We exposed the HCEC to a steady WSS of 0.5 dyne/cm2 for durations of 15 and 30 min. Cytoskeletal alterations and MUC1 secretions were studied using immunohistochemically fluorescent staining with specific antibodies. We investigated for the first time an in vitro model of membrane-tethered mucin secretion by HCEC in response to WSS. The exposure of HCEC to WSS increased the polymerization of F-actin, altered the cytoskeletal shape and reduced the secretion of membrane-tethered MUC1.
Collapse
Affiliation(s)
- Shir Itah
- Department of Biomedical Engineering, Faculty of Engineering, Tel-Aviv University, Tel-Aviv 69978, Israel
| | - David Elad
- Department of Biomedical Engineering, Faculty of Engineering, Tel-Aviv University, Tel-Aviv 69978, Israel
| | - Ariel J. Jaffa
- Department of Obstetrics and Gynecology, Tel-Aviv University, Tel-Aviv 69978, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel-Aviv 69978, Israel
| | - Dan Grisaru
- Sackler Faculty of Medicine, Tel Aviv University, Tel-Aviv 69978, Israel
- Department of Gynecological Oncology, Lis Maternity Hospital, Tel-Aviv Medical Center, Tel-Aviv 64239, Israel
| | - Mordechai Rosner
- Sackler Faculty of Medicine, Tel Aviv University, Tel-Aviv 69978, Israel
- Department of Ophthalmology, Sheba Medical Center, Ramat-Gan 52620, Israel
- Assuta Medical Centers, Tel-Aviv 69710, Israel
| |
Collapse
|
11
|
Jiang H, Fang M, Franklin R, Simms AG, Fadli Z, Wang J. Associations Between Lid Wiper Microvascular Responses, Lens Fit, and Comfort After One Day of Contact Lens Adaptation by Neophytes. Eye Contact Lens 2022; 48:340-346. [PMID: 35580543 PMCID: PMC9329170 DOI: 10.1097/icl.0000000000000898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/29/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine associations between lid wiper microvascular responses, lens fit, and comfort after 1 day of contact lens adaptation by neophytes. METHODS Functional slitlamp biomicroscopy was used to image the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva. Fractal dimension was obtained to represent vessel density. Ultra-high-resolution optical coherence tomography was used to image the lens edge and fitting characteristics, including lens movement and lens-induced conjunctival indentation. Ocular comfort was rated using a 50-point visual analogue scale (VAS). Forty-nine healthy subjects without a history of contact lens wear were recruited. A contact lens was then fitted in the right eye. Imaging was taken at baseline and 6 hr after lens wear. RESULTS The changes of VAS comfort score were negatively related to the changes of the vessel density in the lid-wiper (R 2 =0.18, P =0.002) and bulbar conjunctiva (R 2 =0.13, P =0.009). However, the changes of VAS were positively related to the changes in vessel density of the tarsal conjunctiva (R 2 =0.11, P =0.02). The changes of ocular microvasculature were not related to the objective metrics of the lens-fitting characteristics ( P >0.05). Similarly, the changes in the VAS comfort score were not related to the objective metrics of the lens-fitting characteristics ( P >0.05). CONCLUSION Contact lens discomfort seemed to relate to lid wiper microvascular responses rather than fitting characteristics after 1 day of contact lens adaptation by neophytes.
Collapse
Affiliation(s)
- Hong Jiang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Department of Neurology, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Min Fang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
- Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Jinan University, Shenzhen, Guangdong, China
| | - Ross Franklin
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | - Ava-Gaye Simms
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Zohra Fadli
- Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA
| | - Jianhua Wang
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
12
|
Finite Element Analysis of Cornea and Lid Wiper during Blink, with and without Contact Lens. J Ophthalmol 2022; 2022:7930334. [PMID: 35620413 PMCID: PMC9129998 DOI: 10.1155/2022/7930334] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Accepted: 04/26/2022] [Indexed: 11/18/2022] Open
Abstract
Ocular surface disorders such as Lid Wiper Epitheliopathy (LWE), Superior Epithelial Arcuate Lesion (SEAL), and contact lens-induced Limbal Stem Cell Deficiency (LSCD) as well as Superior Limbic Keratoconjunctivitis (SLK) affect one’s quality of life. Hence, it is imperative to investigate the underlying causes of these ocular surface disorders. During blink, the undersurface of the eyelid tends to interact with the cornea and the conjunctiva. The presence of a contact lens can add to the biomechanical frictional changes on these surfaces. To estimate these changes with and without a contact lens, a finite element model (FEM) of the eyelid wiper, eyeball, and contact lens was developed using COMSOL Multiphysics. Biomechanical properties such as von Mises stress (VMS) and displacement were calculated. Our study concluded that (a) maximum VMS was observed in the lid wiper in the absence of contact lens in the eye and (b) maximum VMS was observed in the superior 1.3 mm of the cornea in the presence of the contact lens in the eye. Thus, the development of friction-induced ocular surface disorders such as LWE, SLK, SEAL, and LSCD could be attributed to increased VMS. FEA is a useful simulation tool that helps us to understand the effect of blink on a normal eye with and without CL.
Collapse
|
13
|
Recchioni A, Mocciardini E, Ponzini E, Tavazzi S. Viscoelastic properties of the human tear film. Exp Eye Res 2022; 219:109083. [PMID: 35460666 DOI: 10.1016/j.exer.2022.109083] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 03/25/2022] [Accepted: 04/18/2022] [Indexed: 12/21/2022]
Abstract
When considering eye blinking from a tribological perspective, tear viscosity is expected to play a fundamental role. The application of rheological techniques to describe the tear film dates back to the late 1980s, but there has been a continuous need of reappraisal due to new findings in tear film biochemistry and to the development of new methods of physico-chemical characterization. This review provides an overview on tear rheological behavior by analyzing the peer-reviewed literature on this topic. Specifically, examples of in-vitro and in-vivo viscosity measurements are detailed, highlighting experimental criticalities and the need of a standard convention for rheological techniques to compare data across different studies, of analyses on tears of single individuals even within the limits of the low volume available, and of a further development of in-vivo techniques. Then, the controversial role of specific tear components on viscosity is discussed, together with the alterations associated to dry eye disease and contact lens wear. Finally, an updated focus is reported on the viscosity of artificial tears formulations.
Collapse
Affiliation(s)
- Alberto Recchioni
- Academic Unit of Ophthalmology, Institute of Inflammation and Ageing, University of Birmingham, UK; Optometry & Vision Sciences Group, School of Life & Health Sciences, Aston University, Birmingham, UK; Birmingham and Midland Eye Centre, Birmingham, UK
| | - Emanuele Mocciardini
- University of Milano Bicocca, Corso di laurea in Ottica e Optometria, via R. Cozzi 55, I-20125, Milan, Italy
| | - Erika Ponzini
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125, Milan, Italy; University of Milano Bicocca, COMiB research center, via R. Cozzi 55, I-20125, Milan, Italy.
| | - Silvia Tavazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125, Milan, Italy; University of Milano Bicocca, COMiB research center, via R. Cozzi 55, I-20125, Milan, Italy
| |
Collapse
|
14
|
Chao C, Lattery L, Qin G, Kamat M, Basso K, Lakkis C, Hasan M, Richdale K. Tear Proteomics of Children and Young Adult Soft Contact Lens, Orthokeratology and Spectacle Wearers - A Pilot Study. Curr Eye Res 2022; 47:832-842. [PMID: 35317695 DOI: 10.1080/02713683.2022.2047206] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
PURPOSE Contact lens complications occur more often in older teenagers and young adults compared to children. This study explored differences in tear proteomics between children and young adults wearing soft contact lens (SCL), orthokeratology or spectacles for >3 years. METHODS Twelve children and 12 sex- and correction-matched young adults were enrolled. Tears were collected via Schirmer strips for tear proteomic analysis using mass spectrometry. Proteome Discoverer was used for protein identification. Label-Free Quantitation was generated using Scaffold software; Fisher's Exact tests were used to compare proteins by age and correction groups. Generalized linear models were used to assess differences in overall protein levels by age and correction groups. A secondary analysis of proteins presented in >50% of samples of each group was conducted using the R/Bioconductor limma package. RESULTS There were 385 proteins present only in young adults while 183 were unique in children. There were 528 unique proteins to SCL, 96 to orthokeratology and 149 to spectacle wearers. Based on Fisher's Exact analyses, 126 proteins were higher in young adults than children (all P < 0.048). Forty-seven protein levels were higher in SCL compared to orthokeratology (all P < 0.01), 33 protein levels were higher in SCL compared to spectacles (all P < 0.01), 15 protein levels were higher in orthokeratology compared to spectacle wearers (all P < 0.01). Based on generalized linear models, young adults had higher overall protein levels than children (P = 0.001), SCL had higher protein levels than spectacle wearers (P < 0.001) but no differences were found between orthokeratology and spectacle wearers (P = 0.79). Based on the secondary analysis, only Antileukoproteinase was higher in the young adult orthokeratology group compared to other groups (P < 0.01). CONCLUSIONS Tear protein type and abundance differ by age and correction. Further research is needed to understand the effects of contact lens correction in children and young adults on the tear proteome.
Collapse
Affiliation(s)
- Cecilia Chao
- College of Optometry, University of Houston, Houston, TX, USA.,School of Optometry and Vision Science, University of New South Wales Sydney, Kensington, Australia
| | - Lauren Lattery
- College of Optometry, University of Houston, Houston, TX, USA
| | - Guoting Qin
- College of Optometry, University of Houston, Houston, TX, USA
| | - Manasi Kamat
- Department of Chemistry, University of Florida, Gainesville, FL, USA
| | - Kari Basso
- Department of Chemistry, University of Florida, Gainesville, FL, USA
| | - Carol Lakkis
- College of Optometry, University of Houston, Houston, TX, USA
| | | | | |
Collapse
|
15
|
Mimura T, Fujishima H, Uchio E, Fukagawa K, Inoue Y, Kawashima M, Kitsu K, Mizota A. Evaluation of Pollen Adhesion to Verofilcon-A Soft Contact Lenses. Open Ophthalmol J 2021. [DOI: 10.2174/1874364102115010305] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Purpose:
A new 1-day disposable soft contact lens (SCL), verofilcon-A, constructed of silicone hydrogel material, has recently become available in Japan. This SCL has a very smooth surface produced by using the SMARTSURFACE ® Technology, and it was expected that pollen particles and protein components would not adhere easily to its surface. We examined the degree of pollen adhesion to the surface of the verofilcon-A material SCL and compared the results with those of other 1-day disposable SCLs (1DSCL).
Methods:
To determine the number of pollen grains attached to the surface of different types of SCLs, 0.01 mg/ml of cedar pollen solution was dropped onto the surface of 13 types of 1DSCL. After 24 h, each 1DSCL was rinsed in a shaker and washed five times with saline (n = 10 for each 1DSCL type). The number of pollen particles adhered to the 1DSCL and the percentage of surface area occupied by pollen was determined.
Results:
The number of pollen particles on the 1DSCLs ranged from 0 to 185 in the 200 × 200 µm area. The number of particles was lowest in the delefilcon-A and verofilcon-A SCLs with 0 particles, and the number was higher in the other 11 1DSCLs. The number of pollen particles was negatively correlated with the water content (r = −0.48), oxygen permeability (Dk; r = −0.43), oxygen transmissibility (r = −0.42), and center thickness (r = −0.33) of the 1DSCLs. The pollen adhesion area ranged from 0.0% to 3.1% and was lowest in the delefilcon-A and verofilcon-A 1DSCLs. There were significant differences in the pollen adhesion area between colored 1DSCLs (2.73 ± 1.97%) and clear 1DSCLs (1.03 ± 1.01%, P<0.001) and between hydroxyethyl methacrylate-based 1DSCLs (1.84 ± 1.45%) and silicone hydrogel-based 1DSCLs (0.05 ± 0.16%, P<0.001).
Conclusion:
These findings indicate that the verofilcon-A 1DSCL processed with SMARTSURFACE™ Technology is an excellent option for SCL users with allergic conjunctivitis during the high pollen season.
Collapse
|
16
|
Ponzini E, Ami D, Duse A, Santambrogio C, De Palma A, Di Silvestre D, Mauri P, Pezzoli F, Natalello A, Tavazzi S, Grandori R. Single-Tear Proteomics: A Feasible Approach to Precision Medicine. Int J Mol Sci 2021; 22:10750. [PMID: 34639092 PMCID: PMC8509675 DOI: 10.3390/ijms221910750] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 09/28/2021] [Accepted: 09/29/2021] [Indexed: 12/23/2022] Open
Abstract
Lacrimal fluid is an attractive source of noninvasive biomarkers, the main limitation being the small sample amounts typically collected. Advanced analytical methods to allow for proteomics profiling from a few microliters are needed to develop innovative biomarkers, with attractive perspectives of applications to precision medicine. This work describes an effective, analytical pipeline for single-tear analysis by ultrahigh-resolution, shotgun proteomics from 23 healthy human volunteers, leading to high-confidence identification of a total of 890 proteins. Highly reproducible quantification was achieved by either peak intensity, peak area, or spectral counting. Hierarchical clustering revealed a stratification of females vs. males that did not emerge from previous studies on pooled samples. Two subjects were monitored weekly over 3 weeks. The samples clustered by withdrawal time of day (morning vs. afternoon) but not by follow-up week, with elevated levels of components of the immune system in the morning samples. This study demonstrates feasibility of single-tear quantitative proteomics, envisaging contributions of this unconventional body fluid to individualized approaches in biomedicine.
Collapse
Affiliation(s)
- Erika Ponzini
- Materials Science Department, University of Milano-Bicocca, Via R. Cozzi 55, 20125 Milan, Italy; (A.D.); (F.P.); (S.T.)
| | - Diletta Ami
- Department of Biotechnology and Biosciences, University of Milano-Bicocca, Piazza della Scienza 2, 20126 Milan, Italy; (D.A.); (C.S.); (A.N.)
| | - Alessandro Duse
- Materials Science Department, University of Milano-Bicocca, Via R. Cozzi 55, 20125 Milan, Italy; (A.D.); (F.P.); (S.T.)
| | - Carlo Santambrogio
- Department of Biotechnology and Biosciences, University of Milano-Bicocca, Piazza della Scienza 2, 20126 Milan, Italy; (D.A.); (C.S.); (A.N.)
| | - Antonella De Palma
- Institute of Technologies in Biomedicine, National Research Council (ITB-CNR), Via Fratelli Cervi 93, 20090 Segrate, Italy; (A.D.P.); (D.D.S.); (P.M.)
| | - Dario Di Silvestre
- Institute of Technologies in Biomedicine, National Research Council (ITB-CNR), Via Fratelli Cervi 93, 20090 Segrate, Italy; (A.D.P.); (D.D.S.); (P.M.)
| | - Pierluigi Mauri
- Institute of Technologies in Biomedicine, National Research Council (ITB-CNR), Via Fratelli Cervi 93, 20090 Segrate, Italy; (A.D.P.); (D.D.S.); (P.M.)
| | - Fabio Pezzoli
- Materials Science Department, University of Milano-Bicocca, Via R. Cozzi 55, 20125 Milan, Italy; (A.D.); (F.P.); (S.T.)
| | - Antonino Natalello
- Department of Biotechnology and Biosciences, University of Milano-Bicocca, Piazza della Scienza 2, 20126 Milan, Italy; (D.A.); (C.S.); (A.N.)
| | - Silvia Tavazzi
- Materials Science Department, University of Milano-Bicocca, Via R. Cozzi 55, 20125 Milan, Italy; (A.D.); (F.P.); (S.T.)
| | - Rita Grandori
- Department of Biotechnology and Biosciences, University of Milano-Bicocca, Piazza della Scienza 2, 20126 Milan, Italy; (D.A.); (C.S.); (A.N.)
| |
Collapse
|
17
|
Wolffsohn JS, Dumbleton K, Huntjens B, Kandel H, Koh S, Kunnen CME, Nagra M, Pult H, Sulley AL, Vianya-Estopa M, Walsh K, Wong S, Stapleton F. CLEAR - Evidence-based contact lens practice. Cont Lens Anterior Eye 2021; 44:368-397. [PMID: 33775383 DOI: 10.1016/j.clae.2021.02.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Evidence-based contact lens -->practice involves finding, appraising and applying research findings as the basis for patient management decisions. These decisions should be informed by the strength of the research study designs that address the question, as well as by the experience of the practitioner and the preferences and environment of the patient. This reports reviews and summarises the published research evidence that is available to inform soft and rigid contact lens history and symptoms taking, anterior eye health examination (including the optimised use of ophthalmic dyes, grading scales, imaging techniques and lid eversion), considerations for contact lens selection (including the ocular surface measurements required to select the most appropriate lens parameter, lens modality and material selection), evaluation of lens fit, prescribing (teaching self-application and removal, adaptation, care regimen and cleaning instructions, as well as -->minimising risks of lens wear through encouraging compliance) and an aftercare routine.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- School of Optometry, University of California, Berkeley, CA, USA
| | - Byki Huntjens
- Division of Optometry and Visual Sciences at City, University of London, London, UK
| | - Himal Kandel
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Japan
| | | | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Cambridge, UK
| | - Heiko Pult
- Optometry and Vision Research, Weinheim, Germany
| | | | - Marta Vianya-Estopa
- Department of Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Karen Walsh
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Stephanie Wong
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
18
|
Mimura T, Fujishima H, Uchio E, Fukagawa K, Kawashima M, Kitsu K, Horikawa H, Mizota A. Adhesion of Pollen Particles to Daily Disposable Soft Contact Lenses. CLINICAL OPTOMETRY 2021; 13:93-101. [PMID: 33790684 PMCID: PMC8007601 DOI: 10.2147/opto.s297531] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 02/13/2021] [Indexed: 06/12/2023]
Abstract
PURPOSE Pollen and proteins attached to soft contact lenses (SCLs) exacerbate allergic conjunctivitis. The material of SCLs may affect the pollen adhesion to the SCLs. The factors associated with the number of pollen particles that are adherent to daily disposable SCL were investigated. METHODS Pollen particles were experimentally exposed to the contact lens surface of 12 types of SCLs for 1 hour, and the SCLs were washed and rinsed with a physiological saline (n=10 for each SCL type). A total of 120 contact lenses were used in this study. The pollen particles attached to the SCL were observed and photographed under a microscope. The influence of the materials of the SCLs on the degree of pollen adhesion were investigated. RESULTS The number of residual pollen particles attached to SCLs was in the range from 0-293/area of 200×200 µm. Percentage of pollen adhesion area of the surface of the SCL was in the range from 0.01% to 3.25%. There were significant differences in both the number and adhesion area of pollen particles among the 12 types of SCLs tested (P<0.0001 and P<0.0001, respectively). The number of pollen particles adhered to SCLs was significantly higher in colored SCLs than clear SCLs (unpaired t-test, p<0.001). The portion of pollen adhesion area was the lowest in the silicone hydrogel SCLs made with delefilcon-A (0.01 ± 0.02%). CONCLUSION Pollen adhesion in daily disposable SCLs depends on the characteristics and materials of the SCLs and was high in colored SCLs and lowest in delefilcon-A silicone hydrogel SCL. These results suggest that colored SCLs are not preferred during pollen season.
Collapse
Affiliation(s)
- Tatsuya Mimura
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Hiroshi Fujishima
- Department of Ophthalmology, Tsurumi University School of Dental Medicine, Yokohama, Kanagawa, Japan
| | - Eiichi Uchio
- Department of Ophthalmology, Fukuoka University School of Medicine, Fukuoka, Japan
| | - Kazumi Fukagawa
- Ryogoku Eye Clinic, Tokyo, Japan
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Makoto Kawashima
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Kazuma Kitsu
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Hiroaki Horikawa
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Atsushi Mizota
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| |
Collapse
|
19
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
20
|
Liu YC, Yam GHF, Lin MTY, Teo E, Koh SK, Deng L, Zhou L, Tong L, Mehta JS. Comparison of tear proteomic and neuromediator profiles changes between small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (LASIK). J Adv Res 2021; 29:67-81. [PMID: 33842006 PMCID: PMC8020296 DOI: 10.1016/j.jare.2020.11.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 10/29/2020] [Accepted: 11/01/2020] [Indexed: 12/19/2022] Open
Abstract
Introduction The tear proteomics and neuromediators are associated with clinical dry eye parameters following refractive surgery. Purpose To investigate and compare the tear proteomic and neuromediator profiles following small incision lenticule extraction (SMILE) versus laser-assisted in-situ keratomileusis (LASIK). Methods In this randomized controlled trial with paired-eye design, 70 patients were randomized to receive SMILE in one eye and LASIK in the other eye. Tear samples were collected preoperatively, and 1 week, 1, 3, 6 and 12 months postoperatively, and were examined for protein concentration changes using sequential window acquisition of all theoretical fragment ion mass spectrometry (SWATH-MS). The data were analyzed with DAVID Bioinformatics Resources for enriched gene ontology terms and over-represented pathways. Tear neuromediators levels were correlated with clinical parameters. Results Post-SMILE eyes had significantly better Oxford staining scores and tear break-up time (TBUT) than post-LASIK eyes at 1 and 3 months, respectively. Tear substance P and nerve growth factor levels were significantly higher in the LASIK group for 3 months and 1 year, respectively. SMILE and LASIK shared some similar biological responses postoperatively, but there was significant up-regulation in leukocyte migration and wound healing at 1 week, humoral immune response and apoptosis at 1 month, negative regulation of endopeptidase activity at 3 to 6 months, and extracellular structure organization at 1 year in the post-LASIK eyes. Tear mucin-like protein 1 and substance P levels were significantly correlated with TBUT (r = -0.47, r = -0.49, respectively). Conclusion Significant differences in the tear neuromediators and proteomics were observed between SMILE and LASIK, even though clinical dry eye signs have subsided and became comparable between 2 procedures.
Collapse
Affiliation(s)
- Yu-Chi Liu
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
- Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore
| | - Gary Hin-Fai Yam
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
- Department of Ophthalmology, University of Pittsburgh, PA, USA
| | - Molly Tzu-Yu Lin
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
| | - Ericia Teo
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
| | - Siew-Kwan Koh
- Ocular Proteomics, Singapore Eye Research Institute, Singapore
| | - Lu Deng
- Department of Statistics and Applied Probability, Faculty of Science, National University of Singapore, Singapore
| | - Lei Zhou
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore
- Ocular Proteomics, Singapore Eye Research Institute, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Louis Tong
- Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore
- Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
- Ocular Surface Group, Singapore Eye Research Institute, Singapore
| | - Jodhbir S. Mehta
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore
- Department of Cornea and External Eye Disease, Singapore National Eye Centre, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Program, Duke-NUS Medical School, Singapore
| |
Collapse
|
21
|
The correction of conjunctivochalasis using high-frequency radiowave electrosurgery improves dry eye disease. Sci Rep 2021; 11:2551. [PMID: 33510304 PMCID: PMC7844232 DOI: 10.1038/s41598-021-82088-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Accepted: 12/31/2020] [Indexed: 11/29/2022] Open
Abstract
We aimed to determine the clinical impact of conjunctivochalasis (CCh) and its correction using high-frequency radiowave electrosurgery (HFR-ES), for signs and symptoms of dry eye disease (DED). Forty patients diagnosed with symptomatic CCh were prospectively enrolled. As a result, patients with CCh had moderate to severe DED and most of them exhibited meibomian gland dysfunction (MGD). Corneo-conjunctival fluorescein staining score (CFS) and all lid-parallel-conjunctival-folds scores (LIPCOFs) were positively correlated. Nasal LIPCOF significantly correlated with symptoms and tear volume. Central, temporal, and total LIPCOF significantly correlated with MG loss, MGD stage, and lipid layer thickness. Independent significant factors associated with total LIPCOF included CFS, tear break-up time, and MGD stage. One month following HFR-ES, CCh was completely resolved in all cases. Patient age and preoperative nasal LIPCOF were determinants of outcomes associated with postoperative improvements in symptoms. Ocular surface parameters significantly improved, but MGD-related signs did not. Collectively, CCh associated with MGD severity deteriorates not only tear film stability and reservoir capacity, leading to DED exacerbation. Therefore, CCh should be corrected in patients with DED and MGD. Younger patients with nasal CCh are likely to experience more symptomatic relief after HFR-ES. Particularly, management for MGD should be maintained after CCh correction.
Collapse
|
22
|
|
23
|
Talens-Estarelles C, García-Marqués JV, Cervino A, García-Lázaro S. Use of digital displays and ocular surface alterations: A review. Ocul Surf 2020; 19:252-265. [PMID: 33053438 DOI: 10.1016/j.jtos.2020.10.001] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 09/15/2020] [Accepted: 10/07/2020] [Indexed: 11/29/2022]
Abstract
Digital display use has been accepted to be implicated as a contributing factor for dry eye disease (DED). Abnormal blinking during computer operation, including a reduced blink rate and an incomplete eyelid closure, increased palpebral fissure as consequence of high visualization angles, and meibomian gland dysfunction associated to long-term display use, are behind the increased prevalence of dry eye signs and symptoms found in digital display users. Previous research reveals significant reductions in tear volume and stability, alterations in tear film composition, including increased osmolarity, inflammatory cytokines, oxidative stress markers and reduced mucin secretion, eyelid abnormalities and ocular surface damage, encompassing corneal and conjunctival staining and bulbar redness, as a direct consequence of digital display use. In this regard, individual differences in the way that the various digital displays are typically set up and used may account for differences in their effects on induced dryness signs and symptoms. Furthermore, factors such as the use of contact lenses or inappropriate working environments, usually accompanying the use of displays, may significantly increase the prevalence and the severity of induced dry eye. Other factors, such as old age and female gender are also relevant in the appearance of associated alterations. Finally, clinicians should adopt a treatment strategy based on a multidirectional approach, with various treatments being applied in conjunction.
Collapse
Affiliation(s)
- Cristian Talens-Estarelles
- Department of Optics & Optometry & Vision Sciences. University of Valencia. Dr. Moliner, 50 46100, Burjassot (Valencia), Spain
| | - José Vicente García-Marqués
- Department of Optics & Optometry & Vision Sciences. University of Valencia. Dr. Moliner, 50 46100, Burjassot (Valencia), Spain
| | - Alejandro Cervino
- Department of Optics & Optometry & Vision Sciences. University of Valencia. Dr. Moliner, 50 46100, Burjassot (Valencia), Spain
| | - Santiago García-Lázaro
- Department of Optics & Optometry & Vision Sciences. University of Valencia. Dr. Moliner, 50 46100, Burjassot (Valencia), Spain.
| |
Collapse
|
24
|
Hyun SW, Song SJ, Park B, Lee TG, Kim CS. Toxicological effects of urban particulate matter on corneal and conjunctival epithelial cells. Toxicol Res 2020; 36:311-318. [PMID: 33005590 DOI: 10.1007/s43188-019-00034-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 11/10/2019] [Accepted: 12/06/2019] [Indexed: 12/27/2022] Open
Abstract
Exposure to urban particulate matter (UPM) is a high-risk factor for various ocular surface diseases, including dry eye syndrome. However, the effects of UPM on corneal and conjunctival epithelium damage have not been fully elucidated. In this study, we investigated the toxicological effects of UPM exposure at high concentrations by using in vitro cultures. The cell viability, mucin expression, and the secreted inflammatory mediators of corneal and conjunctival epithelial cells was observed at 24 h after exposure to UPM. The progression of cell cycle was also examined by flow cytometry at 24 h after exposure to UPM. UPM reduced cell viability in a dose-dependent manner and increased cell population in S and G2 phase. The expression of mucin-1 was attenuated by UPM exposure, but that of mucin-4 was not. UPM increased interleukin (IL)-6 release and decreased IL-8 release. The intensity of 2',7'-dichlorofluorescein diacetate (DCF-DA) was highest at 4 h of UPM exposure. In conclusion, these results suggest that UPM causes the disruption of corneal and conjunctival epithelium by decreasing cell viability, altering cell cycle, disrupting mucin, and regulating inflammatory mediators.
Collapse
Affiliation(s)
- Soo-Wang Hyun
- Herbal Medicine Research Division, Korea Institute of Oriental Medicine, Daejeon, 34054 Korea.,Present Address: Medicinal Evaluation Team, Bio-Center, Gyeonggido Business and Science Accelerator (GBSA), Suwon, Gyeonggi-do 16229 Korea
| | - Su Jeong Song
- Herbal Medicine Research Division, Korea Institute of Oriental Medicine, Daejeon, 34054 Korea
| | - Bongkyun Park
- Clinical Medicine Division, Korea Institute of Oriental Medicine, 1672 Yusengdae-ro, Daejeon, 34054 Korea
| | - Tae Gu Lee
- Clinical Medicine Division, Korea Institute of Oriental Medicine, 1672 Yusengdae-ro, Daejeon, 34054 Korea
| | - Chan-Sik Kim
- Clinical Medicine Division, Korea Institute of Oriental Medicine, 1672 Yusengdae-ro, Daejeon, 34054 Korea.,Korean Convergence Medicine, University of Science Technology (UST), Daejeon, 34054 Korea
| |
Collapse
|
25
|
Omali NB, Subbaraman LN, Heynen M, Lada M, Canavan K, Fadli Z, Ngo W, Jones L. Lipid deposition on contact lenses in symptomatic and asymptomatic contact lens wearers. Cont Lens Anterior Eye 2020; 44:56-61. [PMID: 32466858 DOI: 10.1016/j.clae.2020.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 05/08/2020] [Accepted: 05/11/2020] [Indexed: 11/18/2022]
Abstract
PURPOSE Lipid deposition on contact lenses (CL) has traditionally been believed to reduce comfort during CL wear. The purpose of this study was to quantify lipid deposition on CL in a group of symptomatic and asymptomatic adapted CL wearers. METHODS This was a single-masked, randomized clinical trial. Only confirmed symptomatic (comfortable lens wear time (CWT) < 8 h and a noticeable reduction in comfort over the course of the day) and asymptomatic (CWT > 10 h and minimal reduction in comfort over the course of the day) participants were recruited to participate in the study. Participants wore senofilcon A lenses in combination with a polyquaternium-based care solution (OPTI-FREE Replenish). Worn CL samples were collected on Day 14. Deposited lipid amounts from the lenses (including cholesteryl ester, cholesterol and triolein) were quantified using a liquid chromatography-mass spectrometry technique. RESULTS Lipid deposition was significantly higher in CL extracts of asymptomatic wearers compared to the symptomatic wearers for all lipid types quantified, including cholesteryl ester (2.1 ± 0.6 vs 1.6 ± 0.5 log μg/lens), cholesterol (1.5 ± 0.3 vs 1.1 ± 0.3 log μg/lens) and triolein (0.3 ± 0.2 vs 0.1 ± 0.1 log μg/lens) (all p < 0.002). The amount of cholesteryl ester deposited was greatest (p = 0.0001), followed by cholesterol, then triolein, for both the asymptomatic and symptomatic groups (both p = 0.0001). CONCLUSION This study demonstrated that the asymptomatic group deposited a significantly greater amount of lipid on their CL. Although lipid levels measured are considered low to trigger any observable clinical deposition, they may influence other clinical outcomes, particularly comfort.
Collapse
Affiliation(s)
- Negar Babaei Omali
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Miriam Heynen
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Mark Lada
- Johnson and Johnson Vision, Jacksonville, USA
| | | | - Zohra Fadli
- Johnson and Johnson Vision, Jacksonville, USA
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
26
|
Mani R, Shobha PS, Thilagavathi S, Prema P, Viswanathan N, Vineet R, Dhanashree R, Angayarkanni N. Altered mucins and aquaporins indicate dry eye outcome in patients undergoing Vitreo-retinal surgery. PLoS One 2020; 15:e0233517. [PMID: 32437405 PMCID: PMC7241722 DOI: 10.1371/journal.pone.0233517] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 05/06/2020] [Indexed: 11/18/2022] Open
Abstract
Vitreo-retinal (VR) surgeries induce conjunctival changes. However, there are no study reports regarding prevalence and severity of dry eye after these surgeries. This study evaluated dry eye outcome after VR surgery. Patients undergoing VR surgery classified as scleral buckle and microincision vitrectomy surgery (n = 44, mean age: 56.09±10.2 years) were recruited. Dry eye evaluation was done before and 8 weeks after surgery (2 weeks after omitting topical eye drops). Conjunctival imprint cytology for goblet cell count and tear Mucin 5AC (MUC5AC) protein estimation was done. Gene expressions of MUC5AC, MUC4, MUC16, Aquaporin 4 (AQP4) and AQP5 were analyzed in the conjunctival imprint cells by qPCR. None of the patients exhibited clinical signs of dry eye after VR surgery. But the conjunctival goblet cell density (GCD) was significantly lowered post-VR surgery (63% cases, **p = 0.012) with no alterations in the tear MUC5AC protein. Post-VR surgery, the conjunctival cell gene expression of MUC4, MUC16 and AQP4 were significantly increased (*p = 0.025, *p = 0.05 and *p = 0.02 respectively) and AQP5 was significantly lowered (*p = 0.037), with no change in MUC5AC expression. Tear cytokines were significantly increased post-VR surgery (anti-inflammatory: IL1RA, IL4, IL5, IL9, FGF; PDGFbb and pro-inflammatory: IL2, IL6, IL15, GMCSF and IFNg). Though clinical signs of dry eye were not observed after VR surgery, ocular surface changes in the form of reduced GCD, altered MUC5AC, MUC4, MUC16, AQP4, AQP5 and cytokines are suggestive of dry eye outcome at the molecular level especially inpatients aged above 51 years, especially female gender and those who are diabetic.
Collapse
Affiliation(s)
- Ramalingam Mani
- RS Mehta Jain Department of Biochemistry and Cell Biology, Vision Research Foundation, SankaraNethralaya, Chennai, India
| | - P. S. Shobha
- Elite School of Optometry, Medical Research Foundation, SankaraNethralaya, Chennai, India
| | - Saravanan Thilagavathi
- Elite School of Optometry, Medical Research Foundation, SankaraNethralaya, Chennai, India
| | - Padmanabhan Prema
- Department of Cornea and Refractive Surgery, Medical Research Foundation, SankaraNethralaya, Chennai, India
| | - Natarajan Viswanathan
- Department of Bio-Statistics, Vision Research Foundation, SankaraNethralaya, Chennai, India
| | - Ratra Vineet
- Department of Comprehensive Ophthalmology, Medical Research Foundation, SankaraNethralaya, Chennai, India
| | - Ratra Dhanashree
- Department of Vitreo-retinal Diseases, Medical Research Foundation, SankaraNethralaya, Chennai, India
| | - Narayanasamy Angayarkanni
- RS Mehta Jain Department of Biochemistry and Cell Biology, Vision Research Foundation, SankaraNethralaya, Chennai, India
| |
Collapse
|
27
|
|
28
|
Georgiev GA, Eftimov P, Yokoi N. Contribution of Mucins towards the Physical Properties of the Tear Film: A Modern Update. Int J Mol Sci 2019; 20:E6132. [PMID: 31817367 PMCID: PMC6941008 DOI: 10.3390/ijms20246132] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 11/30/2019] [Accepted: 12/02/2019] [Indexed: 12/18/2022] Open
Abstract
Instability of the tear film (TF) protecting the ocular surface results in dry eye syndrome (DES), the most prevalent public health ophthalmic disease affecting the quality of life of 10 to 30% of the human population worldwide. Although the impact of the tear film lipid layer (TFLL) and of the aqueous tears (AT) to the TF stability is extensively studied, in contrast the contribution of the secretory mucins (SM) and of the membrane-associated mucins (MAM), i.e., one of the most abundant molecular classes in AT and in the corneal epithelium respectively, remains poorly defined. However, it is well known that in DES both types of mucins are quantitatively or qualitatively deficient. Numerous studies since the 1990s until now have proposed direct involvement of SM and MAM in the material properties (viscoelasticity, hydration, and protection of the ocular surface; synergistic cooperation with the rest of the TF layers; etc.) and stability of TF. These theories will be reviewed here in the context of the classical and modern in vitro and in vivo results that allow their reappraisal and in view of the novel mucin secretion enhancing pharmaceuticals, which have opened innovative routes for the therapy of DES.
Collapse
Affiliation(s)
- Georgi As Georgiev
- Department of Optics and Spectroscopy, Faculty of Physics, St. Kliment Ohridski University of Sofia, 5 James Bourchier Blvd, 1164 Sofia, Bulgaria
| | - Petar Eftimov
- Department of Cytology, Histology and Embryology, Faculty of Biology, St. Kliment Ohridski University of Sofia, 8 Dragan Tzankov Blvd., 1164 Sofia, Bulgaria
| | - Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-0841, Japan
| |
Collapse
|
29
|
Predictive Potential of Eyelids and Tear Film in Determining Symptoms in Contact Lens Wearers. Optom Vis Sci 2019; 95:1035-1045. [PMID: 30339638 DOI: 10.1097/opx.0000000000001290] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
SIGNIFICANCE Early diagnosis of clinical markers of contact lens discomfort can help clinicians set realistic expectations and monitor and provide prophylactic management for contact lens wearers. PURPOSE The purpose of this study was to evaluate the potential of eyelid- and tear film-related clinical markers to be used as predictive factors for diagnosing discomfort in contact lens wearers. METHODS A cross-sectional study was performed on 30 contact lens wearers (6 male, 24 female) with median age of 23 years (range, 18 to 41 years). Eyelid signs and tear film characteristics were evaluated during a single visit, and subjects completed the Contact Lens Dry Eye Questionnaire to evaluate ocular discomfort. Area under the curve (AUC) statistics and sensitivity and specificity values from receiver operating characteristic curves were analyzed to evaluate the predictive potential of clinical signs in discriminating symptoms of contact lens discomfort. RESULTS The presence of foam at meibomian gland orifices (AUC, 0.944; P < .05; sensitivity >0.7), meibomian gland secretion volume (AUC, 0.935; P < .05; sensitivity >0.7), quality (AUC, 0.969; P < .05; sensitivity >0.7), and expressibility (AUC, 0.933; P < .05; sensitivity >0.7) were significant and strong predictors of discomfort in lens wear. Tear evaporation rates with (AUC, 0.779; P < .05; sensitivity >0.7) or without contact lenses (AUC, 0.788; P < .05; sensitivity >0.7), palpebral conjunctival roughness (AUC, 0.859; P < .05; sensitivity >0.7), palpebral conjunctival staining (AUC, 0.817; P < .05; sensitivity >0.7), palpebral conjunctival hyperemia (AUC, 0.746; P < .05; sensitivity >0.7), meibomian gland orifice capping (AUC, 0.873; P < .05; sensitivity >0.7), pouting (AUC, 0.891; P < .05; sensitivity >0.7), and lid-parallel conjunctival folds (AUC, 0.770; P < .05; sensitivity >0.7) were other acceptable discriminators of symptoms of discomfort during contact lens wear. An equation was developed to identify symptomatic from asymptomatic lens wearers based on the significant predictors: Symptom discriminant function score = 3.378 (meibomian gland secretion grade) + 0.224 (meibomian gland morphology grade) + 0.61 (tear evaporation rate without contact lenses) + 0.439 (lid-parallel conjunctival folds grade) - 0.346 (palpebral conjunctival health grade) - 4.625. CONCLUSIONS This study demonstrated that clinical signs related to meibomian gland secretions and morphology, tear evaporation, lid-parallel conjunctival folds, and palpebral conjunctival health may successfully predict symptoms of discomfort in contact lens wearers.
Collapse
|
30
|
Dry Eye Symptoms May Have Association With Psychological Stress in Medical Students. Eye Contact Lens 2019; 45:310-314. [DOI: 10.1097/icl.0000000000000567] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
31
|
Read ML, Navascues-Cornago M, Keir N, Maldonado-Codina C, Morgan PB. The impact of contact lens wear on ocular surface mucins using a novel clinical fluorescence imaging system. Cont Lens Anterior Eye 2019; 43:378-388. [PMID: 31451311 DOI: 10.1016/j.clae.2019.08.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 08/14/2019] [Accepted: 08/15/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE Fluorescein-labelled wheat germ agglutinin (F-WGA) acts as a marker for ocular surface mucins. This clinical study sought to investigate whether the degree of F-WGA fluorescence observed at the ocular surface differed between symptomatic contact lens wearers, asymptomatic contact lens wearers and non-contact lens wearers, using a novel imaging system. METHODS Twenty-five participants (10 symptomatic contact lens wearers, 10 asymptomatic contact lens wearers and 5 non-contact lens wearers) attended a single study visit. Photographs of the cornea, bulbar and tarsal conjunctiva were captured following application of F-WGA solution. RESULTS The imaging system captured high-resolution images of F-WGA fluorescence at the ocular surface. The degree of fluorescence differed between the ocular surface regions (p < 0.001). A significant difference in fluorescence was observed between participant groups for the cornea (p = 0.01), with both the symptomatic and asymptomatic contact lens wearers showing lower fluorescence than the non-lens wearers. F-WGA associated fluorescence appeared diminished in the lid wiper region of the symptomatic lens wearers, compared to the asymptomatic group (p = 0.025). CONCLUSION The use of F-WGA as a clinical marker for ocular surface mucins allows an improved understanding of their distribution across the ocular surface. Contact lens wear appears to negatively impact mucin density across the ocular surface, with the most marked effect on the cornea. F-WGA fluorescence appeared diminished in the lid wiper region for the symptomatic contact lens wearing group, indicating that mechanical interaction in this region may play a role in the aetiology of contact lens discomfort. Given the ability of F-WGA to disclose mucin distribution across the ocular surface it is likely to be a key clinical tool in furthering our understanding of (i) the aetiology of contact lens related discomfort, (ii) contact lens designs/materials to minimise interaction with the ocular surface and (iii) dry eye disease and other ocular surface diseases.
Collapse
Affiliation(s)
- Michael L Read
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| | - Maria Navascues-Cornago
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| | - Nancy Keir
- CooperVision Inc., 6150 Stoneridge Mall Rd, Pleasanton, CA 94588, USA.
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| |
Collapse
|
32
|
Pult H, Riede-Pult BH. Impact of soft contact lenses on lid- parallel conjunctival folds. Cont Lens Anterior Eye 2019; 42:415-419. [DOI: 10.1016/j.clae.2018.12.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2018] [Revised: 12/11/2018] [Accepted: 12/11/2018] [Indexed: 11/26/2022]
|
33
|
Simsek C, Dogru M, Shinzawa M, Den S, Kojima T, Iseda H, Suzuki M, Shibasaki Y, Yoshida N, Shimazaki J. The Efficacy of 2% Topical Rebamipide on Conjunctival Squamous Metaplasia and Goblet Cell Density in Dry Eye Disease. J Ocul Pharmacol Ther 2019; 35:350-358. [PMID: 31259647 PMCID: PMC6659741 DOI: 10.1089/jop.2018.0130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Accepted: 04/26/2019] [Indexed: 01/03/2023] Open
Abstract
Purpose: To clarify the pharmacological effects of 2% rebamipide eye drops on mucosal membrane functions of the ocular surface epithelium, we investigated keratoconjunctival alterations at the cellular level in this study. Methods: Fifteen patients with definite dry eye disease were recruited from outpatient clinics of the Department of Ophthalmology, Ichikawa General Hospital. The patients received treatment with 2% rebamipide eye drops q.i.d for 12 weeks. Symptom score assessment, tear film breakup time, fluorescein and lissamine green ocular surface vital staining, grading of lid wiper epitheliopathy, Cochet-Bonnet corneal sensitivity, assessment of squamous metaplasia grades, and goblet cell density calculations from conjunctival impression cytology samples, as well as evaluation of nucleocytoplasmic ratios and corneal epithelial cells from in vivo confocal microscopy images before and 3 months after treatment were performed. Results: The mean symptom scores, tear film breakup time values, ocular surface fluorescein and lissamine green vital staining scores, and lid wiper scores showed a significant improvement after treatment (P < 0.01). The mean squamous metaplasia grade also showed a significant improvement (1.2 ± 0.1 → 0.3 ± 0.1) 3 months after treatment (P = 0.004). There were similar significant improvements in the mean corneal epithelial cell density (660.1 ± 62.6 → 1015.5 ± 43.5 cells/mm2) (P = 0.002) and nucleocytoplasmic ratios (0.1 ± 0.0 → 0.2 ± 0.0) (P = 0.0042) after treatment. Conclusions: Topical use of 2% rebamipide for 3 months was associated with improvements in ocular surface differentiation due to changes of mucosal functions at the cellular level. These alterations may explain objective and subjective improvements in dry eye disease.
Collapse
Affiliation(s)
- Cem Simsek
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Murat Dogru
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
- Department of Ophthalmology, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Megumi Shinzawa
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
- Department of Ophthalmology, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Seika Den
- Department of Ophthalmology, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Takashi Kojima
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Hiroyuki Iseda
- Department of Ophthalmology, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Mai Suzuki
- Department of Ophthalmology, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| | - Yoshiyuki Shibasaki
- Department of Medical Affairs, Otsuka Pharmaceutical Co., Ltd., Tokyo, Japan
| | - Naoshi Yoshida
- Department of Medical Affairs, Otsuka Pharmaceutical Co., Ltd., Tokyo, Japan
| | - Jun Shimazaki
- Department of Ophthalmology, Tokyo Dental College, Ichikawa General Hospital, Chiba, Japan
| |
Collapse
|
34
|
Lid wiper epitheliopathy: The influence of multiple lid eversions and exposure time. Cont Lens Anterior Eye 2019; 42:304-310. [DOI: 10.1016/j.clae.2018.09.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2018] [Revised: 08/20/2018] [Accepted: 09/13/2018] [Indexed: 12/24/2022]
|
35
|
Hyun SW, Kim J, Park B, Jo K, Lee TG, Kim JS, Kim CS. Apricot Kernel Extract and Amygdalin Inhibit Urban Particulate Matter-Induced Keratoconjunctivitis Sicca. Molecules 2019; 24:molecules24030650. [PMID: 30759852 PMCID: PMC6384987 DOI: 10.3390/molecules24030650] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Accepted: 02/12/2019] [Indexed: 11/16/2022] Open
Abstract
Exposure to particulate matter is a risk factor for various ocular surface diseases, including keratoconjunctivitis sicca (KCS). In this study, we investigated the protective effects of apricot kernel extract (AKE) and its bioactive compound, amygdalin, on KCS induced by exposure to urban particulate matter (UPM). In the in vivo experiments, eye drops containing 0.5 mg/mL AKE (AKE-0.5) or 1 mg/mL AKE (AKE-1) were administered directly into the eyes of female rats after UPM exposure. Additionally, the effect of AKE and amygdalin on matrix metalloproteinases (MMPs) activity and the expressions of inflammatory factors, including tumor necrosis factor (TNF)-α and interleukin (IL)-6, was investigated in conjunctival epithelial cells in vitro. Topical administration of AKE-1 attenuated UPM exposure-induced reduction of tear secretion. Both AKE-0.5 and AKE-1 inhibited UPM exposure-induced corneal epithelial damage and irregularity. AKE also protected against UPM exposure-induced disruption of the mucin-4 layer on the ocular surface. In addition, AKE and amygdalin prevented UPM-induced activation of MMPs and upregulation of TNF-α and IL-6 in conjunctival epithelial cells. Therefore, AKE may have protective effects against UPM exposure-induced KCS via the inhibition of MMPs and inflammation. The pharmacological activities of AKE may be in part due to its bioactive compound, amygdalin.
Collapse
Affiliation(s)
- Soo-Wang Hyun
- Herbal Medicine Research Division, Korea Institute of Oriental Medicine, Daejeon 34054, Korea.
| | - Junghyun Kim
- Department of Oral Pathology, School of Dentistry, Chonbuk National University, Jeonju 54896, Korea.
| | - Bongkyun Park
- Clinical Medicine Division, Korea Institute of Oriental Medicine, Daejeon 34054, Korea.
| | - Kyuhyung Jo
- Clinical Medicine Division, Korea Institute of Oriental Medicine, Daejeon 34054, Korea.
| | - Tae Gu Lee
- Clinical Medicine Division, Korea Institute of Oriental Medicine, Daejeon 34054, Korea.
| | - Jin Sook Kim
- Herbal Medicine Research Division, Korea Institute of Oriental Medicine, Daejeon 34054, Korea.
| | - Chan-Sik Kim
- Clinical Medicine Division, Korea Institute of Oriental Medicine, Daejeon 34054, Korea.
- Korean Medicine Life Science, University of Science and Technology (UST), Daejeon 34054, Korea.
| |
Collapse
|
36
|
Evaluation of Objective Signs and Subjective Symptoms of Dry Eye Disease in Patients with Inflammatory Bowel Disease. BIOMED RESEARCH INTERNATIONAL 2019; 2019:8310583. [PMID: 30729131 PMCID: PMC6341274 DOI: 10.1155/2019/8310583] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 12/12/2018] [Accepted: 12/20/2018] [Indexed: 12/30/2022]
Abstract
Aim To evaluate tear film parameters and relationship of objective clinical signs and subjective symptoms of dry eye disease (DED) in inflammatory bowel disease (IBD) subgroups. Methods 39 patients with Crohn's disease (CD), 26 patients with ulcerative colitis (UC), and 39 control persons with no ocular symptoms or surface disorders were included in this prospective, case-control, and cross-sectional study. The ocular surface disease index (OSDI) questionnaire was applied to evaluate dry eye symptoms, and objective tests of DED were performed on both eyes of each subject. Results The average of OSDI scores was 30.59 (±16.68) in CD patients, 24.67 (±23.48) in UC patients, and 11.19 (±5.8) in controls. Except for tear film breakup time (tBUT) and Schirmer-I values other objective parameters were better in UC patients, than in CD patients. CD patients rather than UC patients tend to develop DED. This was associated with immunosuppressant and TNF-α inhibitor use. Conclusions Clinicians must be aware of the spectrum of DED involvement in IBD and suggest using artificial tears in order to decrease severity of ocular complications.
Collapse
|
37
|
Abstract
PURPOSE The observation of lid-parallel conjunctival folds (LIPCOF) is reported to be useful in dry eye diagnoses. Around 70% of the European clinicians use this test in a dry eye clinic. This study investigated the sensitivity and specificity of LIPCOF to predict dry eye. METHODS Ocular Surface Disease Index (OSDI) outcome, noninvasive break-up time (NIKBUT) using the Keratograph (Oculus, Wetzlar, Germany), and LIPCOF of 148 randomized selected patient reports (88 females; mean age=37.0±12.9 years) from 3 different sites were analyzed. Subjects were divided into dry eye and non-dry eye groups by OSDI only, named symptomatic dry eye (OSDI scores ≥15) and by a composite score (OSDI scores ≥15 and NIKBUTaverage of ≤9 sec). RESULTS Lid-parallel conjunctival folds (temporal, nasal, Sum [=temporal+nasal]) were significantly correlated to OSDI and to NIKBUTaverage (Spearman; r>-0.185, P<0.013). NIKBUTaverage (r=-0.322; P<0.001) was significantly correlated to OSDI scores. Based on the OSDI questionnaire, 37.2% of the subjects were symptomatic and 14.7% were positive for dry eye based on the composite score. Lid-parallel conjunctival folds were a significant discriminator between healthy and dry eye subjects (P≤0.001). The areas under the receiver operating characteristic curve for temporal LIPCOF, nasal LIPCOF, and LIPCOF Sum were 0.716, 0.737, and 0.771, respectively, for the symptomatic dry eye group and 0.771, 0.719, and 0.798, respectively, for the composite dry eye group. CONCLUSIONS As LIPCOF demonstrated high predictive ability of dry eye; it appears to be a promising test in the diagnoses of dry eye.
Collapse
|
38
|
Abstract
PURPOSE This study evaluated relationships between meibomian gland loss (MGL) and age, sex, and dry eye. METHODS Dry eye and MGL of the lower eyelid was evaluated from 112 randomly selected subjects (66 women; mean age 62.8; SD ±15.7; and age range: 19-89 years) from Horst Riede GmbH, Weinheim, Germany. In addition, subjects were grouped into dry eye and non-dry eye by the Ocular Surface Disease Index (OSDI) score, lid-parallel conjunctival folds and non-invasive break-up time. Symptoms were evaluated by the OSDI. Meibography of the lower eyelid was performed using a Cobra camera (bon Optic, Lübeck, Germany), and images were analyzed by its digital grading tool. Data were analyzed by backward, multiple regression analyses and Pearson correlation. RESULTS Analyzing all subjects, multiple regression analyses detected that age and dry eye status (dry eye diagnosis or OSDI) but not sex were significantly related to MGL. In both, non-dry eye (n=66) and dry eye subjects (n=46), dry eye status (OSDI) but not age or sex was significantly related to MGL. Ocular Surface Disease Index scores were significantly correlated with MGL, but this correlation was stronger among all subjects (Pearson correlation; r=0.536, P<0.001) and dry eye group subjects (r=0.520, P<0.001) than in non-dry eye group subjects (r=0.275, P=0.014). CONCLUSIONS Dry eye group subjects showed significantly increased MGL of the lower eyelid. Age and dry eye status were related to MGL of the lower eyelid, but sex was not; dry eye status was the dominant factor.
Collapse
|
39
|
Baudouin C, Rolando M, Benitez Del Castillo JM, Messmer EM, Figueiredo FC, Irkec M, Van Setten G, Labetoulle M. Reconsidering the central role of mucins in dry eye and ocular surface diseases. Prog Retin Eye Res 2018; 71:68-87. [PMID: 30471351 DOI: 10.1016/j.preteyeres.2018.11.007] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 11/16/2018] [Accepted: 11/21/2018] [Indexed: 01/16/2023]
Abstract
Mucins are key actors in tear film quality and tear film stability. Alteration of membrane-bound mucin expression on corneal and conjunctival epithelial cells and/or gel-forming mucin secretion by goblet cells (GCs) promotes in ocular surface diseases and dry eye disease (DED). Changes in the mucin layer may lead to enhanced tear evaporation eventually contributing to tear hyperosmolarity which has been associated with ocular surface inflammation. Inflammatory mediators in turn may have a negative impact on GCs differentiation, proliferation, and mucin secretion. This sheds new light on the position of GCs in the vicious circle of DED. As contributor to ocular surface immune homeostasis, GC loss may contribute to impaired ocular surface immune tolerance observed in DED. In spite of this, there are no tools in routine clinical practice for exploring ocular surface mucin deficiency/dysregulation. Therefore, when selecting the most appropriate treatment options, there is a clear unmet need for a better understanding of the importance of mucins and options for their replacement. Here, we comprehensively revisited the current knowledge on ocular surface mucin biology, including functions, synthesis, and secretion as well as the available diagnostic tools and treatment options to improve mucin-associated homeostasis. In particular, we detailed the potential link between mucin dysfunction and inflammation as part of the uncontrolled chronic inflammation which perpetuates the vicious circle in DED.
Collapse
Affiliation(s)
- Christophe Baudouin
- Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, Paris, University Versailles Saint Quentin en Yvelines, Paris, France.
| | - Maurizio Rolando
- Ocular Surface & Dry Eye Center, ISPRE Ophthalmics, Genoa, Italy
| | | | | | - Francisco C Figueiredo
- Department of Ophthalmology, Royal Victoria Infirmary and Institute of Genetic Medicine, Newcastle University, Newcastle Upon Tyne, UK
| | - Murat Irkec
- Department of Ophthalmology, Hacettepe Faculty of Medicine, Ankara, Turkey
| | | | - Marc Labetoulle
- Hôpital Bicêtre, APHP, South Paris University, Ophthalmology, Le Kremlin-Bicêtre, France
| |
Collapse
|
40
|
Lid-parallel conjunctival fold (LIPCOF) morphology imaged by optical coherence tomography and its relationship to LIPCOF grade. Cont Lens Anterior Eye 2018; 42:299-303. [PMID: 30442513 DOI: 10.1016/j.clae.2018.10.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 10/28/2018] [Accepted: 10/31/2018] [Indexed: 11/24/2022]
Abstract
PURPOSE Lid-parallel conjunctival folds (LIPCOF) are a well-accepted clinical sign in dry eye diagnosis. Commonly, LIPCOF is classified by grading the number of folds observed by slit-lamp microscope. This study investigated the relationship between subjective grading scale and LIPCOF morphology imaged by optical coherence tomography (OCT). METHODS Temporal and nasal LIPCOF of 42 subjects (mean age 27.3 ± 8.4 (SD) years; 13 M, 29 F) were observed and classified by an experienced optometrist using the Pult LIPCOF grading scale (0: no permanent, lid-parallel conjunctival fold; 1: one fold; 2: two folds, 3: three or more folds). Additionally, LIPCOF cross-sectional area (LIPCOF-A) and fold count (LIPCOF-C), as imaged by OCT (Cirrus HD; Carl Zeiss Meditec, Jena, Germany), were analysed with ImageJ 1.50 (http://rsbweb.nih.gov/ij). Correlations between subjective grading and LIPCOF-A and LIPCOF-C were analysed by Spearman correlation, differences between subjective grading and LIPCOF-C were analysed by Wilcoxon test. RESULTS For temporal and nasal sectors, mean subjective LIPCOF grade was 1.43 ± 0.86 grade units and 0.57 ± 0.80 grade units, mean LIPCOF-C was 1.67 ± 0.82 folds and 0.69 ± 0.78 folds, and mean LIPCOF-A was 0.0676 ± 0.0236mm2 and 0.0389 ± 0.0352 mm2, respectively. Subjective temporal and nasal LIPCOF grade was significantly correlated to LIPCOF-C (r = 0.610, p < 0.001 and r = 0.645, p < 0.001, respectively), and to LIPCOF-A (r = 0.612, p < 0.001 and r = 0.583, p < 0.001, respectively). LIPCOF-C was not statistical different to subjective LIPCOF grade (p = 0.07 and p = 0.239; temporal and nasal sectors, respectively). CONCLUSIONS OCT allows for better imaging of finer details of LIPCOF morphology, and especially of LIPCOF area. OCT evaluation of LIPCOF area correlated well with subjective grading and appears to be a promising objective method for LIPCOF classification.
Collapse
|
41
|
Mcmonnies CW. Tear instability importance, mechanisms, validity and reliability of assessment. JOURNAL OF OPTOMETRY 2018; 11:203-210. [PMID: 29337016 PMCID: PMC6147744 DOI: 10.1016/j.optom.2017.11.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 10/28/2017] [Accepted: 11/29/2017] [Indexed: 06/07/2023]
Abstract
PURPOSE To examine the factors which contribute to tear stability and the validity and reliability of methods used for assessing tear break up time which is a core part of an examination of tear stability in dry eye patients. METHODS A review of publications which are relevant to tear stability and its assessment. RESULTS Tear break up time may be more invasive than intended if difficulty avoiding blinking during assessment results in reflex tearing. Notwithstanding control of instilled volume and concentration of fluorescein, on-eye dilution is highly variable according to resident tear volume. Blinking to evenly distribute fluorescein may improve tear and lipid layer thickness so habitual tear function is not assessed. Emphasis on a role for Meibomian gland dysfunction as a cause of tear instability may be appropriate in many cases but ignores the roles for other sources of tear lipid and other non-lipid contributions to tear instability such as aqueous or mucus deficiency, desiccated epitheliopathy or anomalous blinking. Objective less-invasive methods eliminate problems of inter-observer variability and can reliably 'maintain vigilance' over wide areas of the tear layer. However less-invasive results to date include mean tear break up findings which are both shorter and longer than expected for normal controls. CONCLUSIONS Fluorescein tear break up time assessments cannot be standardised and less-invasive methods are not yet standardised. Objective less-invasive and subjective fluorescein break up time tests do not appear to be measuring the same tear phenomena although both should be performed before other invasive procedures.
Collapse
Affiliation(s)
- Charles W Mcmonnies
- School of Optometry and Vision Science, University of New South Wales, Kensington 2052, Australia.
| |
Collapse
|
42
|
Siddireddy JS, Vijay AK, Tan J, Willcox M. The eyelids and tear film in contact lens discomfort. Cont Lens Anterior Eye 2018; 41:144-153. [DOI: 10.1016/j.clae.2017.10.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 09/20/2017] [Accepted: 10/06/2017] [Indexed: 11/24/2022]
|
43
|
Stahl U, Jalbert I. Exploring the links between contact lens comfort, osmolarity and lid wiper staining. Cont Lens Anterior Eye 2018; 41:110-116. [DOI: 10.1016/j.clae.2017.09.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2017] [Revised: 09/11/2017] [Accepted: 09/11/2017] [Indexed: 12/23/2022]
|
44
|
Patient-reported Outcomes for Assessment of Quality of Life in Refractive Error: A Systematic Review. Optom Vis Sci 2017; 94:1102-1119. [PMID: 29095758 DOI: 10.1097/opx.0000000000001143] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE This review has identified the best existing patient-reported outcome (PRO) instruments in refractive error. The article highlights the limitations of the existing instruments and discusses the way forward. PURPOSE A systematic review was conducted to identify the types of PROs used in refractive error, to determine the quality of the existing PRO instruments in terms of their psychometric properties, and to determine the limitations in the content of the existing PRO instruments. METHODS Articles describing a PRO instrument measuring 1 or more domains of quality of life in people with refractive error were identified by electronic searches on the MEDLINE, PubMed, Scopus, Web of Science, and Cochrane databases. The information on content development, psychometric properties, validity, reliability, and responsiveness of those PRO instruments was extracted from the selected articles. The analysis was done based on a comprehensive set of assessment criteria. RESULTS One hundred forty-eight articles describing 47 PRO instruments in refractive error were included in the review. Most of the articles (99 [66.9%]) used refractive error-specific PRO instruments. The PRO instruments comprised 19 refractive, 12 vision but nonrefractive, and 16 generic PRO instruments. Only 17 PRO instruments were validated in refractive error populations; six of them were developed using Rasch analysis. None of the PRO instruments has items across all domains of quality of life. The Quality of Life Impact of Refractive Correction, the Quality of Vision, and the Contact Lens Impact on Quality of Life have comparatively better quality with some limitations, compared with the other PRO instruments. CONCLUSIONS This review describes the PRO instruments and informs the choice of an appropriate measure in refractive error. We identified need of a comprehensive and scientifically robust refractive error-specific PRO instrument. Item banking and computer-adaptive testing system can be the way to provide such an instrument.
Collapse
|
45
|
Lippestad M, Hodges RR, Utheim TP, Serhan CN, Dartt DA. Resolvin D1 Increases Mucin Secretion in Cultured Rat Conjunctival Goblet Cells via Multiple Signaling Pathways. Invest Ophthalmol Vis Sci 2017; 58:4530-4544. [PMID: 28892824 PMCID: PMC5595227 DOI: 10.1167/iovs.17-21914] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Purpose Goblet cells in the conjunctiva secrete mucin into the tear film protecting the ocular surface. The proresolution mediator resolvin D1 (RvD1) regulates mucin secretion to maintain homeostasis during physiological conditions and in addition, actively terminates inflammation. We determined the signaling mechanisms used by RvD1 in cultured rat conjunctival goblet cells to increase intracellular [Ca2+] ([Ca2+]i) and induce glycoconjugate secretion. Methods Increase in [Ca2+]i were measured using fura 2/AM and glycoconjugate secretion determined using an enzyme-linked lectin assay with the lectin Ulex Europaeus Agglutinin 1. Signaling pathways activated by RvD1 were studied after goblet cells were pretreated with signaling pathway inhibitors before stimulation with RvD1. The results were compared with results when goblet cells were stimulated with RvD1 alone and percent inhibition calculated. Results The increase in [Ca2+]i stimulated by RvD1 was blocked by inhibitors to phospholipases (PL-) -D, -C, -A2, protein kinase C (PKC), extracellular signal-regulated kinases (ERK)1/2 and Ca2+/calmodulin-dependent kinase (Ca2+/CamK). Glycoconjugate secretion was significantly inhibited by PLD, -C, -A2, ERK1/2 and Ca2+/CamK, but not PKC. Conclusions We conclude that RvD1 increases glycoconjugate secretion from goblet cells via multiple signaling pathways including PLC, PLD, and PLA2, as well as their signaling components ERK1/2 and Ca2+/CamK to preserve the mucous layer and maintain homeostasis by protecting the eye from desiccating stress, allergens, and pathogens.
Collapse
Affiliation(s)
- Marit Lippestad
- Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, United States.,Faculty of Medicine, University of Oslo, Oslo, Norway.,Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway
| | - Robin R Hodges
- Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, United States
| | - Tor P Utheim
- Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, United States.,Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway.,Department of Oral Biology, Faculty of Dentistry, University of Oslo, Oslo, Norway
| | - Charles N Serhan
- Center for Experimental Therapeutics and Reperfusion Injury, Department of Anesthesia, Perioperative and Pain Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts, United States
| | - Darlene A Dartt
- Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, United States.,Department of Oral Biology, Faculty of Dentistry, University of Oslo, Oslo, Norway
| |
Collapse
|
46
|
Abstract
PURPOSE To assess the impact of lens-free intervals of varying lengths on end-of-day comfort with soft contact lenses. METHODS Twenty-five symptomatic lens wearers participated in this randomized, cross-over study involving nine individual 12-hour days: one spectacle (no lens) and eight lens wear days. On each lens wear day, lenses were worn bilaterally in 2-hour intervals, separated by lens-free (recovery) periods of 0, 30, 60, or 80 minutes (repeated throughout the day). For each 2-hour lens wear interval, new lenses were worn. Ocular comfort was rated on a 0 to 100 visual analogue scale (0 = extremely uncomfortable); tear film and ocular parameters were assessed at the beginning and end of each study day. This study involved two different types of silicone hydrogel lenses, and the order of lens type and length of recovery period was randomized. Participants were unaware of the true study purpose and that a new lens pair was used for each lens wear interval. RESULTS End-of-day comfort on lens wear days was significantly worse than on the spectacle day (p < 0.002). There was no significant effect of the recovery periods on end-of-day comfort (p > 0.05). Although lens wear affected noninvasive tear film break-up time and conjunctival staining, there were no effects of recovery period length on noninvasive tear film break-up time (p > 0.05), tear meniscus height (p > 0.05), corneal staining (p > 0.05), conjunctival staining (p > 0.05), bulbar conjunctival redness (p > 0.05), or limbal redness (p > 0.05). There was no consistent effect of recovery period length on lid margin staining. CONCLUSIONS Lens-free recovery periods during a 12-hour lens wear day did not positively impact end-of-day comfort in this study. Cumulative lens wear times ranged from 8 to 12 hours, and the results suggest that once the length of lens wear exceeds the usual comfortable wear time, there is no benefit of short recovery periods.
Collapse
|
47
|
Gomes JAP, Azar DT, Baudouin C, Efron N, Hirayama M, Horwath-Winter J, Kim T, Mehta JS, Messmer EM, Pepose JS, Sangwan VS, Weiner AL, Wilson SE, Wolffsohn JS. TFOS DEWS II iatrogenic report. Ocul Surf 2017; 15:511-538. [PMID: 28736341 DOI: 10.1016/j.jtos.2017.05.004] [Citation(s) in RCA: 258] [Impact Index Per Article: 36.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2017] [Accepted: 05/02/2017] [Indexed: 01/04/2023]
Abstract
Dry eye can be caused by a variety of iatrogenic interventions. The increasing number of patients looking for eye care or cosmetic procedures involving the eyes, together with a better understanding of the pathophysiological mechanisms of dry eye disease (DED), have led to the need for a specific report about iatrogenic dry eye within the TFOS DEWS II. Topical medications can cause DED due to their allergic, toxic and immuno-inflammatory effects on the ocular surface. Preservatives, such as benzalkonium chloride, may further aggravate DED. A variety of systemic drugs can also induce DED secondary to multiple mechanisms. Moreover, the use of contact lens induces or is associated with DED. However, one of the most emblematic situations is DED caused by surgical procedures such as corneal refractive surgery as in laser-assisted in situ keratomileusis (LASIK) and keratoplasty due to mechanisms intrinsic to the procedure (i.e. corneal nerve cutting) or even by the use of postoperative topical drugs. Cataract surgery, lid surgeries, botulinum toxin application and cosmetic procedures are also considered risk factors to iatrogenic DED, which can cause patient dissatisfaction, visual disturbance and poor surgical outcomes. This report also presents future directions to address iatrogenic DED, including the need for more in-depth epidemiological studies about the risk factors, development of less toxic medications and preservatives, as well as new techniques for less invasive eye surgeries. Novel research into detection of early dry eye prior to surgeries, efforts to establish appropriate therapeutics and a greater attempt to regulate and oversee medications, preservatives and procedures should be considered.
Collapse
Affiliation(s)
- José Alvaro P Gomes
- Dept. of Ophthalmology and Visual Sciences, Federal University of Sao Paulo/Paulista School of Medicine (UNIFESP/EPM), São Paulo, SP, Brazil.
| | - Dimitri T Azar
- University of Illinois College of Medicine, Chicago, IL, USA
| | | | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Queensland, Australia
| | - Masatoshi Hirayama
- Department of Ophthalmology, School of Medicine, Keio University, Tokyo, Japan
| | | | - Terry Kim
- Duke University School of Medicine, Durham, NC, USA; Duke University Eye Center, Durham, NC, USA
| | | | - Elisabeth M Messmer
- Department of Ophthalmology, Ludwig-Maximilians-University (LMU), Munich, Germany
| | - Jay S Pepose
- Washington University School of Medicine, St. Louis, MO, USA
| | | | | | - Steven E Wilson
- Cole Eye Institute, The Cleveland Clinic, Cleveland, OH, USA
| | | |
Collapse
|
48
|
TFOS DEWS II Diagnostic Methodology report. Ocul Surf 2017; 15:539-574. [DOI: 10.1016/j.jtos.2017.05.001] [Citation(s) in RCA: 836] [Impact Index Per Article: 119.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2017] [Accepted: 05/01/2017] [Indexed: 01/09/2023]
|
49
|
McMonnies CW. Better methods of clinically assessing mucus functions are required. JOURNAL OF OPTOMETRY 2017; 10:69-70. [PMID: 28372637 PMCID: PMC5383455 DOI: 10.1016/j.optom.2017.03.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Affiliation(s)
- Charles W McMonnies
- Adjunct Professor, School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
50
|
Abstract
OBJECTIVE To review the effect of contact lens (CL) material, design, and fitting characteristics on CL discomfort. METHODS A PubMed search identified publications describing subjective comfort and CL material, fitting, and design parameters. The review included clinical signs associated with discomfort that may be a consequence of these parameters. RESULTS Reduced lens movement or more CL tightness were associated with improved comfort. Increased lens-induced paralimbal conjunctival staining and indentation, considered as quasi-indicators of CL fitting or edge design, were also associated with better comfort. No recent studies have evaluated varying CL design parameters and subjective comfort. Silicone hydrogel CLs are no different in comfort compared with hydrogel CLs. Lower equilibrium water content is associated with improved comfort in hydrogel CL wear. Coefficient of friction shows promise as a material factor potentially associated with comfort. Lid wiper epitheliopathy and lid-parallel conjunctival folds have been linked with comfort in established wearers. CONCLUSIONS Recent studies have confirmed the association between more mobile CLs and more discomfort, whereas closer conformity of the CL to the bulbar conjunctiva improved subjective comfort. There is no evidence to support the perceived comfort difference between silicone hydrogel and hydrogel CL. There has been limited progress in understanding the impact of varying specific CL design parameters. Although specific clinical signs may be predictive of discomfort, their role in the natural history of discomfort remains unclear. A better understanding of the relationship between coefficient of friction and comfort and strategies to improve lubricity may hold promise for limiting CL discomfort.
Collapse
|