1
|
Jacobs PS, Wilson N, Brink W, Swain A, Armbruster R, Hanumapur A, Tisdall MD, Detre J, Nanga RPR, Elliott MA, Reddy R. In vivo B 1 + enhancement of calf MRI at 7 T via optimized flexible metasurfaces. Magn Reson Med 2024; 92:1277-1289. [PMID: 38469893 PMCID: PMC11209820 DOI: 10.1002/mrm.30060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/18/2024] [Accepted: 02/05/2024] [Indexed: 03/13/2024]
Abstract
PURPOSE Ultrahigh field (≥7 T) MRI is at the cutting edge of medical imaging, enabling enhanced spatial and spectral resolution as well as enhanced susceptibility contrast. However, transmit (B 1 + $$ {\mathrm{B}}_1^{+} $$ ) field inhomogeneity due to standing wave effects caused by the shortened RF wavelengths at 7 T is still a challenge to overcome. Novel hardware methods such as dielectric pads have been shown to improve theB 1 + $$ {\mathrm{B}}_1^{+} $$ field inhomogeneity but are currently limited in their corrective effect by the range of high-permittivity materials available and have a fixed shelf life. In this work, an optimized metasurface design is presented that demonstrates in vivo enhancement of theB 1 + $$ {\mathrm{B}}_1^{+} $$ field. METHODS A prototype metasurface was optimized by an empirical capacitor sweep and by varying the period size. Phantom temperature experiments were performed to evaluate potential metasurface heating effects during scanning. Lastly, in vivo gradient echo images andB 1 + $$ {\mathrm{B}}_1^{+} $$ maps were acquired on five healthy subjects on a 7 T system. Dielectric pads were also used as a comparison throughout the work as a standard comparison. RESULTS The metasurfaces presented here enhanced the average relative SNR of the gradient echo images by a factor of 2.26 compared to the dielectric pads factor of 1.61. AverageB 1 + $$ {\mathrm{B}}_1^{+} $$ values reflected a similar enhancement of 27.6% with the metasurfaces present versus 8.9% with the dielectric pads. CONCLUSION The results demonstrate that metasurfaces provide superior performance to dielectric padding as shown byB 1 + $$ {\mathrm{B}}_1^{+} $$ maps reflecting their direct effects and resulting enhancements in image SNR at 7 T.
Collapse
Affiliation(s)
- Paul S Jacobs
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Neil Wilson
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Wyger Brink
- Magnetic Detection and Imaging group, TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Anshuman Swain
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Ryan Armbruster
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Aniketh Hanumapur
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - M. Dylan Tisdall
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - John Detre
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
- Department of Neurology, University of Pennsylvania, Philadelphia, PA, United States
| | - Ravi Prakash Reddy Nanga
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Mark A. Elliott
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Ravinder Reddy
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| |
Collapse
|
2
|
Koloskov V, Brink WM, Webb AG, Shchelokova A. Flexible metasurface for improving brain imaging at 7T. Magn Reson Med 2024; 92:869-880. [PMID: 38469911 DOI: 10.1002/mrm.30088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 02/14/2024] [Accepted: 03/01/2024] [Indexed: 03/13/2024]
Abstract
PURPOSE Ultra-high field MRI offers unprecedented detail for noninvasive visualization of the human brain. However, brain imaging is challenging at 7T due to the B 1 + $$ {}_1^{+} $$ field inhomogeneity, which results in signal intensity drops in temporal lobes and a bright region in the brain center. This study aims to evaluate using a metasurface to improve brain imaging at 7T and simplify the investigative workflow. METHODS Two flexible metasurfaces comprising a periodic structure of copper strips and parallel-plate capacitive elements printed on an ultra-thin substrate were optimized for brain imaging and implemented via PCB. We considered two setups: (1) two metasurfaces located near the temporal lobes and (2) one metasurface placed near the occipital lobe. The effect of metasurface placement on the transmit efficiency and specific absorption rate was evaluated via electromagnetic simulation studies with voxelized models. In addition, their impact on signal-to-noise ratio (SNR) and diagnostic image quality was assessed in vivo for two male and one female volunteers. RESULTS Placement of metasurfaces near the regions of interest led to an increase in homogeneity of the transmit field by 5% and 10.5% in the right temporal lobe and occipital lobe for a male subject, respectively. SAR efficiency values changed insignificantly, dropping by less than 8% for all investigated setups. In vivo studies also confirmed the numerically predicted improvement in field distribution and receive sensitivity in the desired ROI. CONCLUSION Optimized metasurfaces enable homogenizing transmit field distribution in the brain at 7T. The proposed lightweight and flexible structure can potentially provide MR examination with higher diagnostic value images.
Collapse
Affiliation(s)
- Vladislav Koloskov
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia
| | - Wyger M Brink
- Magnetic Detection & Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Andrew G Webb
- C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Alena Shchelokova
- School of Physics and Engineering, ITMO University, St. Petersburg, Russia
| |
Collapse
|
3
|
Sayyid ZN, Jung D, Chen JX, Paez AG, Hua J, Deng F, Carey JP, Ward BK. Clinical Application of 7T MRI: A Case Study of Vestibular Schwannoma Imaging. Otol Neurotol 2024; 45:e494-e496. [PMID: 38773857 PMCID: PMC11239100 DOI: 10.1097/mao.0000000000004210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2024]
Affiliation(s)
- Zahra N Sayyid
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Diane Jung
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Jenny X Chen
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Adrian G Paez
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD
| | | | - Francis Deng
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD
| | - John P Carey
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Bryan K Ward
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD
| |
Collapse
|
4
|
Jacobs PS, Brink W, Reddy R. A review of recent developments and applications of high-permittivity dielectric shimming in magnetic resonance. NMR IN BIOMEDICINE 2024; 37:e5094. [PMID: 38214202 DOI: 10.1002/nbm.5094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/20/2023] [Accepted: 11/29/2023] [Indexed: 01/13/2024]
Abstract
We present a review outlining the basic mechanism, background, recent technical developments, and clinical applications of aqueous dielectric padding in the field of MRI. Originally meant to be a temporary solution, it has gained traction as an effective method for correcting B1 + inhomogeneities due to the unique properties of the calcium titanate and barium titanate perovskites used. Aqueous dielectric pads have used a variety of high-permittivity materials over the years to improve the quality of MRI acquisitions at 1.5 and 3 T and more recently for 7 T neuroimaging applications. The technical development and assessment of these pads have been advanced by an increased use of mathematical modeling and electromagnetic simulations. These tools have allowed for a more complete understanding of the physical interactions between dielectric pads and the RF coil, making testing and safety assessments more accurate. The ease of use and effectiveness that dielectric pads offer have allowed them to become more commonplace in tackling imaging challenges in more clinically focused environments. More recently, they have seen usage not only in anatomical imaging methods but also in specialized metabolic imaging sequences such as GluCEST and NOEMTR . New colossally high-permittivity materials have been proposed; however, practical utilization has been a continued challenge due to unfavorable frequency dependences as well as safety limitations. A new class of metasurfaces has been under development to address the shortcomings of conventional dielectric padding while also providing increased performance in enhancing MRI images.
Collapse
Affiliation(s)
- Paul S Jacobs
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Wyger Brink
- Magnetic Detection and Imaging group, TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Ravinder Reddy
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
5
|
Jacobs PS, Benyard B, Cao Q, Swain A, Wilson N, Nanga RPR, Tisdall MD, Detre J, Elliott MA, Haris M, Reddy R. B 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneity correction of volumetric brain NOE MTR via high permittivity dielectric padding at 7 T. Magn Reson Med 2023; 90:1537-1546. [PMID: 37279010 PMCID: PMC10425166 DOI: 10.1002/mrm.29739] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 04/23/2023] [Accepted: 05/16/2023] [Indexed: 06/07/2023]
Abstract
PURPOSE Nuclear Overhauser effect magnetization transfer ratio (NOEMTR ) is a technique used to investigate brain lipids and macromolecules in greater detail than other techniques and benefits from increased contrast at 7 T. However, this contrast can become degraded because ofB 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities present at ultra-high field strengths. High-permittivity dielectric pads (DP) have been used to correct for these inhomogeneities via displacement currents generating secondary magnetic fields. The purpose of this work is to demonstrate that dielectric pads can be used to mitigateB 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities and improve NOEMTR contrast in the temporal lobes at 7 T. METHODS Partial 3D NOEMTR contrast images and whole brainB 1 + $$ {\mathrm{B}}_1^{+} $$ field maps were acquired on a 7 T MRI across six healthy subjects. Calcium titanate DP, having a relative permittivity of 110, was placed next to the subject's head near the temporal lobes. Pad corrected NOEMTR images had a separate postprocessing linear correction applied. RESULTS DP provided supplementalB 1 + $$ {\mathrm{B}}_1^{+} $$ to the temporal lobes while also reducing theB 1 + $$ {\mathrm{B}}_1^{+} $$ magnitude across the posterior and superior regions of the brain. This resulted in a statistically significant increase in NOEMTR contrast in substructures of the temporal lobes both with and without linear correction. The padding also produced a convergence in NOEMTR contrast toward approximately equal mean values. CONCLUSION NOEMTR images showed significant improvement in temporal lobe contrast when DP were used, which resulted from an increase inB 1 + $$ {\mathrm{B}}_1^{+} $$ homogeneity across the entire brain slab. DP-derived improvements in NOEMTR are expected to increase the robustness of the brain substructural measures both in healthy and pathological conditions.
Collapse
Affiliation(s)
- Paul S Jacobs
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Blake Benyard
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Quy Cao
- Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, PA, United States
| | - Anshuman Swain
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Neil Wilson
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Ravi Prakash Reddy Nanga
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - M. Dylan Tisdall
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - John Detre
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
- Department of Neurology, University of Pennsylvania, Philadelphia, PA, United States
| | - Mark A Elliott
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Mohammad Haris
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| | - Ravinder Reddy
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
| |
Collapse
|
6
|
Brink WM, Remis RF, Webb AG. Radiofrequency safety of high permittivity pads in MRI-Impact of insulation material. Magn Reson Med 2023; 89:2109-2116. [PMID: 36708148 DOI: 10.1002/mrm.29580] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 11/30/2022] [Accepted: 12/26/2022] [Indexed: 01/29/2023]
Abstract
PURPOSE High permittivity dielectric pads are known to be effective for tailoring the RF field and improving image quality in high field MRI. Despite a number of studies reporting benign specific absorption rate (SAR) effects, their "universal" safety remains an open concern. In this work, we evaluate the impact of the insulation material in between the pad and the body, using both RF simulations as well as phantom experiments. METHODS A 3T configuration with high permittivity material was simulated and characterized experimentally in terms of B1 + fields and RF power absorption, both with and without electrical insulation in between the high permittivity material and the sample. Different insulation conditions were compared, and electromagnetic analyses on the induced current density were performed to elucidate the effect. RESULTS Increases in RF heating of up to 49% were observed experimentally in a tissue-mimicking phantom after removing the material insulation. The B1 + magnitude and RF transceive phase were not affected. Simulations indicated that an insulation thickness of 0.5-2 mm should be accounted for in numerical models in order to ensure reliable results. CONCLUSION A reliable RF safety assessment of high permittivity dielectric pads requires accounting for the insulating properties of the plastic encasing. Ignoring the electrical insulation can lead to erroneous results with substantial increases in local SAR at the interface. Conversely, the material insulation does not need to be modeled to predict the B1 + effects during the design of the pad geometry.
Collapse
Affiliation(s)
- Wyger M Brink
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.,Magnetic Detection & Imaging Group, TechMed Centre, University of Twente, Enschede, The Netherlands
| | - Rob F Remis
- Circuits and Systems Group, Department of Microelectronics, Delft University of Technology, Delft, The Netherlands
| | - Andrew G Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
7
|
Jacobs PS, Benyard B, Cember A, Nanga RPR, Cao Q, Tisdall MD, Wilson N, Das S, Davis KA, Detre J, Roalf D, Reddy R. Repeatability of B 1 + inhomogeneity correction of volumetric (3D) glutamate CEST via High-permittivity dielectric padding at 7T. Magn Reson Med 2022; 88:2475-2484. [PMID: 36178233 PMCID: PMC9529237 DOI: 10.1002/mrm.29409] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 12/03/2023]
Abstract
PURPOSE Ultra-high field MR imaging lacks B1 + inhomogeneity due to shorter RF wavelengths used at higher field strengths compared to human anatomy. CEST techniques tend to be highly susceptible to B1 + inhomogeneities due to a high and uniform B1 + field being necessary to create the endogenous contrast. High-permittivity dielectric pads have seen increasing usage in MR imaging due to their ability to tailor the spatial distribution of the B1 + field produced. The purpose of this work is to demonstrate that dielectric materials can be used to improve glutamate weighted CEST (gluCEST) at 7T. THEORY AND METHODS GluCEST images were acquired on a 7T system on six healthy volunteers. Aqueous calcium titanate pads, with a permittivity of approximately 110, were placed on either side in the subject's head near the temporal lobes. A post-processing correction algorithm was implemented in combination with dielectric padding to compare contrast improvement. Tissue segmentation was performed to assess the effect of dielectric pads on gray and white matter separately. RESULTS GluCEST images demonstrated contrast enhancement in the lateral temporal lobe regions with dielectric pad placement. Tissue segmentation analysis showed an increase in correction effectiveness within the gray matter tissue compared to white matter tissue. Statistical testing suggested a significant difference in gluCEST contrast when pads were used and showed a difference in the gray matter tissue segment. CONCLUSION The use of dielectric pads improved the B1 + field homogeneity and enhanced gluCEST contrast for all subjects when compared to data that did not incorporate padding.
Collapse
Affiliation(s)
- Paul S Jacobs
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Blake Benyard
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Abigail Cember
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravi Prakash Reddy Nanga
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Quy Cao
- Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - M Dylan Tisdall
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Neil Wilson
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Sandhitsu Das
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Kathryn A Davis
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - John Detre
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
- Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - David Roalf
- Department of Psychiatry, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravinder Reddy
- Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
8
|
Nagururu NV, Akbar A, Ward BK. Using magnetic resonance imaging to improve diagnosis of peripheral vestibular disorders. J Neurol Sci 2022; 439:120300. [DOI: 10.1016/j.jns.2022.120300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 05/18/2022] [Accepted: 05/23/2022] [Indexed: 12/01/2022]
|
9
|
Novel materials in magnetic resonance imaging: high permittivity ceramics, metamaterials, metasurfaces and artificial dielectrics. MAGNETIC RESONANCE MATERIALS IN PHYSICS, BIOLOGY AND MEDICINE 2022; 35:875-894. [PMID: 35471464 PMCID: PMC9596558 DOI: 10.1007/s10334-022-01007-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 02/18/2022] [Accepted: 03/07/2022] [Indexed: 11/01/2022]
Abstract
AbstractThis article reviews recent developments in designing and testing new types of materials which can be: (i) placed around the body for in vivo imaging, (ii) be integrated into a conventional RF coil, or (iii) form the resonator itself. These materials can improve the quality of MRI scans for both in vivo and magnetic resonance microscopy applications. The methodological section covers the basic operation and design of two different types of materials, namely high permittivity materials constructed from ceramics and artificial dielectrics/metasurfaces formed by coupled conductive subunits, either in air or surrounded by dielectric material. Applications of high permittivity materials and metasurfaces placed next to the body to neuroimaging and extremity imaging at 7 T, body and neuroimaging at 3 T, and extremity imaging at 1.5 T are shown. Results using ceramic resonators for both high field in vivo imaging and magnetic resonance microscopy are also shown. The development of new materials to improve MR image quality remains an active area of research, but has not yet found significant use in clinical applications. This is mainly due to practical issues such as specific absorption rate modelling, accurate and reproducible placement, and acceptable size/weight of such materials. The most successful area has been simple “dielectric pads” for neuroimaging at 7 T which were initially developed somewhat as a stop-gap while parallel transmit technology was being developed, but have continued to be used at many sites. Some of these issues can potentially be overcome using much lighter metasurfaces and artificial dielectrics, which are just beginning to be assessed.
Collapse
|
10
|
Zhao AJ, Liu BC, Gao CY, Quan DZ, Xia EL, Zhang FX. Evaluation of high-dielectric pads for macaque brain imaging at 7 T. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:104101. [PMID: 34717383 DOI: 10.1063/5.0057847] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 09/08/2021] [Indexed: 06/13/2023]
Abstract
A non-human primate is a valuable model for investigating the structure and function of the brain. Different from the human brain imaging using radio frequency (RF) head coils, in the present study, on a human whole-body 7 T magnetic resonance imaging system, we used an RF knee coil for monkey brain imaging in vivo due to the smaller size of the macaque's brain compared to that of a human, and particularly, high-dielectric pads were also utilized in order to improve brain imaging performance. Our experimental results suggest that high-dielectric pads can effectively enhance the B1 field strength and receive sensitivity, leading to a higher flip-angle magnitude, an image signal-to-noise ratio, and tissue contrast, and in the meantime, we did not observe elevated receive array element coupling and receive noise amplification nor apparent magnetic susceptibility-induced artifact or distortion, showing that the pads do not introduce adverse RF interferences in macaque brain imaging at 7 T.
Collapse
Affiliation(s)
- A Jie Zhao
- Key Laboratory for Biomedical Engineering of Ministry of Education, Zhejiang University, Hangzhou 310027, China
| | - B Chunyi Liu
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection & School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, China
| | - C Yang Gao
- Interdisciplinary Institute of Neuroscience and Technology, School of Medicine, Zhejiang University, Hangzhou 310029, China
| | - D Zhiyan Quan
- Interdisciplinary Institute of Neuroscience and Technology, School of Medicine, Zhejiang University, Hangzhou 310029, China
| | - E Ling Xia
- Key Laboratory for Biomedical Engineering of Ministry of Education, Zhejiang University, Hangzhou 310027, China
| | - F Xiaotong Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Zhejiang University, Hangzhou 310027, China
| |
Collapse
|
11
|
Evaluation of the whole auditory pathway using high-resolution and functional MRI at 7T parallel-transmit. PLoS One 2021; 16:e0254378. [PMID: 34492032 PMCID: PMC8423236 DOI: 10.1371/journal.pone.0254378] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 06/24/2021] [Indexed: 11/29/2022] Open
Abstract
Purpose The aim of the present study is to show a MR procedure for the evaluation of simultaneous left and right auditory functions with functional MRI, and high-resolution acquisition of anatomical auditory pathway using parallel-transmit (pTx) methods at 7T. Methods The time-efficient MR acquisition included two steps: RF weights were optimized for the regions-of-interest and high-resolution MR images of the inner-ear were acquired for the first 30 min (400 μm-iso resolution) followed by functional MRI acquisitions along the whole auditory pathway during the next 20 minutes. Data was processed with a linear cross-correlation analysis to define frequency preferences for each voxel in the auditory relays. Results Tonotopic maps revealed ordered bilateral frequency gradients in the auditory relays whereas at the level of the cochlear nuclei and superior olivary complexes the frequency gradients were less evident. A 21% increase in transmit-field efficiency was achieved over the left/right inner-ear regions and thus its main structures were clearly discernible using the pTx methods, compared to a single transmit RF coil. Conclusion Using 7T pTx allows a fast (less than 60 min in total) and qualitative evaluation of the simultaneous left and right auditory response along the entire auditory pathway, together with high-resolution anatomical images of the inner-ear. This could be further used for patient examination at 7T.
Collapse
|
12
|
Mitigation of B 1+ inhomogeneity for ultra-high-field magnetic resonance imaging: hybrid mode shaping with auxiliary EM potential. Sci Rep 2020; 10:11752. [PMID: 32678182 PMCID: PMC7366730 DOI: 10.1038/s41598-020-68651-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 06/29/2020] [Indexed: 11/25/2022] Open
Abstract
The notion of mode shaping based on evanescent coupling has been successfully applied in various fields of optics, such as in the dispersion engineering of optical waveguides. Here, we show that the same concept provides an opportunity for the seemingly different field of ultra-high-field MRI, addressing transmit RF magnetic field (B1+) inhomogeneity. In this work, treating the human phantom as a resonator, we employ an evanescently coupled high-index cladding layer to study the effects of the auxiliary potential on shaping the B1+ field distribution inside the phantom. Controlling the strength and coupling of the auxiliary potential ultimately determining the hybridized mode, we successfully demonstrate the global 2D homogenization of axial B1+ for a simplified cylindrical phantom and for a more realistic phantom of spheroidal geometry. The mode-shaping potentials with a magnetic permeability or material loss are also tested to offer additional degrees of freedom in the selection of materials as well as in the manipulation of the B1+ distribution, opening up the possibility of B1+ homogenization for 3D MRI scanning.
Collapse
|
13
|
Delgado PR, Kuehne A, Periquito JS, Millward JM, Pohlmann A, Waiczies S, Niendorf T. B 1 inhomogeneity correction of RARE MRI with transceive surface radiofrequency probes. Magn Reson Med 2020; 84:2684-2701. [PMID: 32447779 DOI: 10.1002/mrm.28307] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 03/27/2020] [Accepted: 04/13/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE The use of surface radiofrequency (RF) coils is common practice to boost sensitivity in (pre)clinical MRI. The number of transceive surface RF coils is rapidly growing due to the surge in cryogenically cooled RF technology and ultrahigh-field MRI. Consequently, there is an increasing need for effective correction of the excitation field ( B 1 + ) inhomogeneity inherent in these coils. Retrospective B1 correction permits quantitative MRI, but this usually requires a pulse sequence-specific analytical signal intensity (SI) equation. Such an equation is not available for fast spin-echo (Rapid Acquisition with Relaxation Enhancement, RARE) MRI. Here we present, test, and validate retrospective B1 correction methods for RARE. METHODS We implemented the commonly used sensitivity correction and developed an empirical model-based method and a hybrid combination of both. Tests and validations were performed with a cryogenically cooled RF probe and a single-loop RF coil. Accuracy of SI quantification and T1 contrast were evaluated after correction. RESULTS The three described correction methods achieved dramatic improvements in B1 homogeneity and significantly improved SI quantification and T1 contrast, with mean SI errors reduced from >40% to >10% following correction in all cases. Upon correction, images of phantoms and mouse heads demonstrated homogeneity comparable to that of images acquired with a volume resonator. This was quantified by SI profile, SI ratio (error < 10%), and percentage of integral uniformity (PIU > 80% in vivo and ex vivo compared to PIU > 87% with the reference RF coil). CONCLUSION This work demonstrates the efficacy of three B1 correction methods tailored for transceive surface RF probes and RARE MRI. The corrected images are suitable for quantification and show comparable results between the three methods, opening the way for T1 measurements and X-nuclei quantification using surface transceiver RF coils. This approach is applicable to other MR techniques for which no analytical SI exists.
Collapse
Affiliation(s)
- Paula Ramos Delgado
- Berlin Ultrahigh Field Facility (B.U.F.F), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | | | - João S Periquito
- Berlin Ultrahigh Field Facility (B.U.F.F), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Jason M Millward
- Berlin Ultrahigh Field Facility (B.U.F.F), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Sonia Waiczies
- Berlin Ultrahigh Field Facility (B.U.F.F), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F), Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,Experimental and Clinical Research Center, a joint cooperation between the Charité Medical Faculty and the Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany.,MRI.TOOLS GmbH, Berlin, Germany
| |
Collapse
|
14
|
Image Artifact Management for Clinical Magnetic Resonance Imaging on a 7 T Scanner Using Single-Channel Radiofrequency Transmit Mode. Invest Radiol 2020; 54:781-791. [PMID: 31503079 DOI: 10.1097/rli.0000000000000598] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVES The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. MATERIALS AND METHODS Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 and B1 inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. RESULTS Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. CONCLUSIONS Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.
Collapse
|
15
|
Ruytenberg T, O'Reilly TP, Webb AG. Design and characterization of receive-only surface coil arrays at 3T with integrated solid high permittivity materials. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 311:106681. [PMID: 31923765 DOI: 10.1016/j.jmr.2019.106681] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/16/2019] [Accepted: 12/28/2019] [Indexed: 06/10/2023]
Abstract
A receive-only surface coil array for 3 Tesla integrating a high-permittivity material (HPM) with a relative permittivity of 660 was designed and constructed and subsequently its performance was evaluated and compared in terms of transmit field efficiency and specific absorption ratio (SAR) during transmission, and signal-to-noise ratio during reception, with a conventional identically-sized surface coil array. Finite-difference time-domain simulations, bench measurements and in-vivo neck imaging on three healthy volunteers were performed using a three-element surface coil array with integrated HPMs placed around the larynx. Simulation results show an increase in local transmit efficiency of the body coil of ~10-15% arising from the presence of the HPM. The receiver efficiency also increased by approximately 15% close to the surface. Phantom experiments confirmed these results. In-vivo scans using identical transmit power resulted in SNR gains throughout the laryngeal area when compared with the conventional surface coil array. In particular specifically around the carotid arteries an average SNR gain of 52% was measured averaged over the three subjects, while in the spine an average of 20% SNR gain was obtained.
Collapse
Affiliation(s)
- Thomas Ruytenberg
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.
| | - Thomas P O'Reilly
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Andrew G Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
16
|
Jethwa K, Aphiwatthanasumet K, Mougin O, Bowtell R, Auer D, Gowland P. Phase enhanced PSIR T1 weighted imaging improves contrast resolution of the nucleus basalis of Meynert at 7 T: a preliminary study. Magn Reson Imaging 2019; 61:296-299. [PMID: 31202788 DOI: 10.1016/j.mri.2019.06.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/29/2019] [Accepted: 06/02/2019] [Indexed: 01/29/2023]
Abstract
BACKGROUND The nucleus basalis of Meynert (NBM) provides the majority of cortical cholinergic innervation which is required for memory formation, maintaining attention and promoting learning. Neuronal loss within this area is implicated in a number of neurodegenerative disorders. Imaging the NBM is however limited by its small size and suboptimal contrast resolution at the base of the brain. PURPOSE To develop a novel method of processing T1 weighted MRI data for improving contrast resolution and delineation of the NBM. STUDY TYPE Technical development, case series. SUBJECTS Five healthy volunteers. FIELD STRENGTH, SEQUENCE, ANALYSIS Volunteers were scanned on a Philips 7 T Achieva imaging system. T1-weighted images were constructed from a double inversion phase sensitive inversion recovery (PSIR) sequence. Inversion recovery data were combined with the filtered phase data from the long inversion time image to produce a novel susceptibility weighted-PSIR (SW-PSIR) map. This process is similar to that used to combine T2* weighted image and phase maps to create susceptibility weighted images (SWI), but with the processing parameters optimized in terms of contrast-to-noise ratio to the NBM in the final SW-PSIR maps. Average NBM thickness was reported as mean ± standard deviation (SD). Intra-observer and inter-observer reliability were tested using intra-class correlation coefficient (ICC). RESULTS 0.7mm3 isotropic resolution images were acquired in a 5 min and 50 s scan. The mean thickness ± SD of the left (right) NBM was 3.5 ± 0.4 mm and 3.8 ± 0.5 mm (3.6 ± 0.5 mm and 3.7 ± 0.5 mm) by the first and second observers respectively with excellent intra-observer and inter-observer agreement (>0.90). CONCLUSION In this pilot study the SW-PSIR imaging approach improves delineation of the NBM between the ventral pallidum and chiasmatic cistern allowing accurate thickness measurement. The role of this sequence, in enabling robust morphometry of the NBM in health and disease, can be tested further in larger studies.
Collapse
Affiliation(s)
- Ketan Jethwa
- National Institute of Health Research Nottingham Biomedical Research Centre, Queens Medical Centre, Derby Road, Nottingham NG7 2UH, United Kingdom; Sir Peter Mansfield Imaging Centre, University Park, University of Nottingham, NG7 2RD, United Kingdom.
| | - Kingkarn Aphiwatthanasumet
- National Institute of Health Research Nottingham Biomedical Research Centre, Queens Medical Centre, Derby Road, Nottingham NG7 2UH, United Kingdom
| | - Olivier Mougin
- National Institute of Health Research Nottingham Biomedical Research Centre, Queens Medical Centre, Derby Road, Nottingham NG7 2UH, United Kingdom
| | - Richard Bowtell
- National Institute of Health Research Nottingham Biomedical Research Centre, Queens Medical Centre, Derby Road, Nottingham NG7 2UH, United Kingdom
| | - Dorothee Auer
- National Institute of Health Research Nottingham Biomedical Research Centre, Queens Medical Centre, Derby Road, Nottingham NG7 2UH, United Kingdom; Sir Peter Mansfield Imaging Centre, University Park, University of Nottingham, NG7 2RD, United Kingdom
| | - Penny Gowland
- National Institute of Health Research Nottingham Biomedical Research Centre, Queens Medical Centre, Derby Road, Nottingham NG7 2UH, United Kingdom
| |
Collapse
|
17
|
Golestanirad L, Angelone LM, Kirsch J, Downs S, Keil B, Bonmassar G, Wald LL. Reducing RF-induced Heating near Implanted Leads through High-Dielectric Capacitive Bleeding of Current (CBLOC). IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES 2019; 67:1265-1273. [PMID: 31607756 PMCID: PMC6788634 DOI: 10.1109/tmtt.2018.2885517] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Patients with implanted medical devices such as deep brain stimulation or spinal cord stimulation are often unable to receive magnetic resonance imaging (MRI). This is because once the device is within the radiofrequency (RF) field of the MRI scanner, electrically conductive leads act as antenna, amplifying the RF energy deposition in the tissue and causing possible excessive tissue heating. Here we propose a novel concept in lead design in which 40cm lead wires are coated with a ~1.2mm layer of high dielectric constant material (155 < ε r < 250) embedded in a weakly conductive insulation (σ = 20S/m). The technique called High-Dielectric Capacitive Bleeding of Current, or CBLOC, works by forming a distributed capacitance along the lengths of the lead, efficiently dissipating RF energy before it reaches the exposed tip. Measurements during RF exposure at 64 MHz and 123 MHz demonstrated that CBLOC leads generated 20-fold less heating at 1.5 T, and 40-fold less heating at 3 T compared to control leads. Numerical simulations of RF exposure at 297 MHz (7T) predicted a 15-fold reduction in specific absorption rate (SAR) of RF energy around the tip of CBLOC leads compared to control leads.
Collapse
Affiliation(s)
- Laleh Golestanirad
- A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Charlestown, MA 02129 USA, and the Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago IL 60611 USA
| | - Leonardo M Angelone
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Device and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| | - John Kirsch
- A. A. Martinos Center for Biomedical Imaging, Charlestown MA 02129 USA (, , , )
| | - Sean Downs
- A. A. Martinos Center for Biomedical Imaging, Charlestown MA 02129 USA (, , , )
| | - Boris Keil
- Department of Life Science Engineering, Institute of Medical Physics and Radiation Protection, Giessen, Germany
| | - Giorgio Bonmassar
- A. A. Martinos Center for Biomedical Imaging, Charlestown MA 02129 USA (, , , )
| | - Lawrence L Wald
- A. A. Martinos Center for Biomedical Imaging, Charlestown MA 02129 USA (, , , )
| |
Collapse
|
18
|
Zivkovic I, Teeuwisse W, Slobozhanyuk A, Nenasheva E, Webb A. High permittivity ceramics improve the transmit field and receive efficiency of a commercial extremity coil at 1.5 Tesla. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019; 299:59-65. [PMID: 30580045 DOI: 10.1016/j.jmr.2018.12.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Revised: 12/07/2018] [Accepted: 12/14/2018] [Indexed: 06/09/2023]
Abstract
OBJECTIVE The purpose of this work is to investigate the use of ceramic materials (based on BaTiO3 with ZrO2 and CeO2-additives) with very high relative permittivity (εr ∼ 4500) to increase the local transmit field and signal-to-noise ratio (SNR) for commercial extremity coils on a clinical 1.5 T MRI system. METHODS Electromagnetic simulations of transmit efficiency and specific absorption rate (SAR) were performed using four ferroelectric ceramic blocks placed around a cylindrical phantom, as well as placing these ceramics around the wrist of a human body model. Results were compared with experimental scans using the transmit body coil of the 1.5 T MRI system and an eight-element extremity receive array designed for the wrist. SNR measurements were also performed for both phantom and in vivo scans. RESULTS Electromagnetic simulations and phantom/in vivo experiments showed an increased in the local transmit efficiency from the body coil of ∼20-30%, resulting in an ∼50% lower transmit power level and a significant reduction in local and global SAR throughout the body. For in vivo wrist experiments, the SNR of a commercial eight-channel receive array, integrated over the entire volume, was improved by ∼45% with the ceramic. CONCLUSION The local transmit efficiency as well as the SNR can be increased for 1.5 T extremity MRI with commercial array coils by using materials with very high permittivity.
Collapse
Affiliation(s)
- Irena Zivkovic
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Wouter Teeuwisse
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Alexey Slobozhanyuk
- Department of Nanophotonics and Metamaterials, ITMO University, Saint Petersburg, Russia
| | | | - Andrew Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.
| |
Collapse
|
19
|
van Gemert J, Brink W, Webb A, Remis R. High-permittivity pad design tool for 7T neuroimaging and 3T body imaging. Magn Reson Med 2018; 81:3370-3378. [PMID: 30561797 PMCID: PMC6519234 DOI: 10.1002/mrm.27629] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2018] [Revised: 10/18/2018] [Accepted: 11/16/2018] [Indexed: 11/20/2022]
Abstract
Purpose High‐permittivity materials in the form of flexible “dielectric pads” have proved very useful for addressing RF inhomogeneities in high field MRI systems. Finding the optimal design of such pads is, however, a tedious task, reducing the impact of this technique. We present an easy‐to‐use software tool which allows researchers and clinicians to design dielectric pads efficiently on standard computer systems, for 7T neuroimaging and 3T body imaging applications. Methods The tool incorporates advanced computational methods based on field decomposition and model order reduction as a framework to efficiently evaluate the B1+ fields resulting from dielectric pads. The tool further incorporates optimization routines which can either optimize the position of a given dielectric pad, or perform a full parametric design. The optimization procedure can target either a single target field, or perform a sweep to explore the trade‐off between homogeneity and efficiency of the B1+ field in a specific region of interest. The 3T version further allows for shifting of the imaging landmark to enable different imaging targets to be centered in the body coil. Results Example design results are shown for imaging the inner ear at 7T and for cardiac imaging at 3T. Computation times for all cases are approximately a minute per target field. Conclusion The developed tool can be easily used to design dielectric pads for any 7T neuroimaging and 3T body imaging application within minutes. This bridges the gap between the advanced design methods and the practical application by the MR community.
Collapse
Affiliation(s)
- Jeroen van Gemert
- Circuits & Systems Group, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands
| | - Wyger Brink
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew Webb
- Circuits & Systems Group, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands
| | - Rob Remis
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
20
|
Studying neurons and glia non-invasively via anomalous subdiffusion of intracellular metabolites. Brain Struct Funct 2018; 223:3841-3854. [DOI: 10.1007/s00429-018-1719-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2018] [Accepted: 07/12/2018] [Indexed: 12/31/2022]
|
21
|
Markenroth Bloch K, Töger J, Ståhlberg F. Investigation of cerebrospinal fluid flow in the cerebral aqueduct using high-resolution phase contrast measurements at 7T MRI. Acta Radiol 2018; 59:988-996. [PMID: 29141450 DOI: 10.1177/0284185117740762] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background The cerebral aqueduct is a central conduit for cerebrospinal fluid (CSF), and non-invasive quantification of CSF flow in the aqueduct may be an important tool for diagnosis and follow-up of treatment. Magnetic resonance (MR) methods at clinical field strengths are limited by low spatial resolution. Purpose To investigate the feasibility of high-resolution through-plane MR flow measurements (2D-PC) in the cerebral aqueduct at high field strength (7T). Material and Methods 2D-PC measurements in the aqueduct were performed in nine healthy individuals at 7T. Measurement accuracy was determined using a phantom. Aqueduct area, mean velocity, maximum velocity, minimum velocity, net flow, and mean flow were determined using in-plane resolutions 0.8 × 0.8, 0.5 × 0.5, 0.3 × 0.3, and 0.2 × 0.2 mm2. Feasibility criteria were defined based on scan time and spatial and temporal resolution. Results Phantom validation of 2D-PC MR showed good accuracy. In vivo, stroke volume was -8.2 ± 4.4, -4.7 ± 2.8, -6.0 ± 3.8, and -3.7 ± 2.1 µL for 0.8 × 0.8, 0.5 × 0.5, 0.3 × 0.3, and 0.2 × 0.2 mm2, respectively. The scan with 0.3 × 0.3 mm2 resolution fulfilled the feasibility criteria for a wide range of heart rates and aqueduct diameters. Conclusion 7T MR enables non-invasive quantification of CSF flow and velocity in the cerebral aqueduct with high spatial resolution.
Collapse
Affiliation(s)
| | - Johannes Töger
- Department of Diagnostic Radiology, Lund University, Skåne University Hospital, Lund, Sweden
| | - Freddy Ståhlberg
- Department of Diagnostic Radiology, Lund University, Skåne University Hospital, Lund, Sweden
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
| |
Collapse
|
22
|
van Gemert JHF, Brink WM, Webb AG, Remis RF. High-Permittivity Pad Design for Dielectric Shimming in Magnetic Resonance Imaging Using Projection-Based Model Reduction and a Nonlinear Optimization Scheme. IEEE TRANSACTIONS ON MEDICAL IMAGING 2018; 37:1035-1044. [PMID: 29610080 DOI: 10.1109/tmi.2018.2791179] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Inhomogeneities in the transmit radio frequency magnetic field ( ) reduce the quality of magnetic resonance (MR) images. This quality can be improved by using high-permittivity pads that tailor the fields. The design of an optimal pad is application-specific and not straightforward and would therefore benefit from a systematic optimization approach. In this paper, we propose such a method to efficiently design dielectric pads. To this end, a projection-based model order reduction technique is used that significantly decreases the dimension of the design problem. Subsequently, the resulting reduced-order model is incorporated in an optimization method in which a desired field in a region of interest can be set. The method is validated by designing a pad for imaging the cerebellum at 7 T. The optimal pad that is found is used in an MR measurement to demonstrate its effectiveness in improving the image quality.
Collapse
|
23
|
Haemer GG, Vaidya M, Collins CM, Sodickson DK, Wiggins GC, Lattanzi R. Approaching ultimate intrinsic specific absorption rate in radiofrequency shimming using high-permittivity materials at 7 Tesla. Magn Reson Med 2017; 80:391-399. [PMID: 29193307 DOI: 10.1002/mrm.27022] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/18/2017] [Accepted: 10/31/2017] [Indexed: 11/07/2022]
Abstract
PURPOSE The aim of this study was to evaluate the effect of integrated high-permittivity materials (HPMs) on excitation homogeneity and global specific absorption rate (SAR) for transmit arrays at 7T. METHODS A rapid electrodynamic simulation framework was used to calculate L-curves associated with excitation of a uniform 2D profile in a dielectric sphere. We used ultimate intrinsic SAR as an absolute performance reference to compare different transmit arrays in the presence and absence of a layer of HPM. We investigated the optimal permittivity for the HPM as a function of its thickness, the sample size, and the number of array elements. RESULTS Adding a layer of HPM can improve the performance of a 24-element array to match that of a 48-element array without HPM, whereas a 48-element array with HPM can perform as well as a 64-element array without HPM. Optimal relative permittivity values changed based on sample and coil geometry, but were always within a range obtainable with readily available materials (εr = 100-200). CONCLUSION Integration of HPMs could be a practical method to improve RF shimming performance, alternative to increasing the number of coils. The proposed simulation framework could be used to explore the design of novel transmit arrays for head imaging at ultra-high field strength. Magn Reson Med 80:391-399, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Gillian G Haemer
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,NYU WIRELESS, New York University Tandon School of Engineering, Brooklyn, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Manushka Vaidya
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,NYU WIRELESS, New York University Tandon School of Engineering, Brooklyn, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Christopher M Collins
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,NYU WIRELESS, New York University Tandon School of Engineering, Brooklyn, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Daniel K Sodickson
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,NYU WIRELESS, New York University Tandon School of Engineering, Brooklyn, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Graham C Wiggins
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Riccardo Lattanzi
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,NYU WIRELESS, New York University Tandon School of Engineering, Brooklyn, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| |
Collapse
|
24
|
Vaidya MV, Deniz CM, Collins CM, Sodickson DK, Lattanzi R. Manipulating transmit and receive sensitivities of radiofrequency surface coils using shielded and unshielded high-permittivity materials. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 31:355-366. [PMID: 29110240 DOI: 10.1007/s10334-017-0657-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 09/29/2017] [Accepted: 10/02/2017] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To use high-permittivity materials (HPM) positioned near radiofrequency (RF) surface coils to manipulate transmit/receive field patterns. MATERIALS AND METHODS A large HPM pad was placed below the RF coil to extend the field of view (FOV). The resulting signal-to-noise ratio (SNR) was compared with that of other coil configurations covering the same FOV in simulations and experiments at 7 T. Transmit/receive efficiency was evaluated when HPM discs with or without a partial shield were positioned at a distance from the coil. Finally, we evaluated the increase in transmit homogeneity for a four-channel array with HPM discs interposed between adjacent coil elements. RESULTS Various configurations of HPM increased SNR, transmit/receive efficiency, excitation/reception sensitivity overlap, and FOV when positioned near a surface coil. For a four-channel array driven in quadrature, shielded HPM discs enhanced the field below the discs as well as at the center of the sample as compared with other configurations with or without unshielded HPM discs. CONCLUSION Strategically positioning HPM at a distance from a surface coil or array can increase the overlap between excitation/reception sensitivities, and extend the FOV of a single coil for reduction of the number of channels in an array while minimally affecting the SNR.
Collapse
Affiliation(s)
- Manushka V Vaidya
- Center for Advanced Imaging Innovation and Research and the Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 First Ave, Fourth Floor, New York, NY, 10016, USA. .,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, 550 First Avenue, New York, NY, 10016, USA. .,NYU WIRELESS, 2 Metro Tech Center, Brooklyn, NY, 11201, USA.
| | - Cem M Deniz
- Center for Advanced Imaging Innovation and Research and the Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 First Ave, Fourth Floor, New York, NY, 10016, USA.,NYU WIRELESS, 2 Metro Tech Center, Brooklyn, NY, 11201, USA
| | - Christopher M Collins
- Center for Advanced Imaging Innovation and Research and the Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 First Ave, Fourth Floor, New York, NY, 10016, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, 550 First Avenue, New York, NY, 10016, USA.,NYU WIRELESS, 2 Metro Tech Center, Brooklyn, NY, 11201, USA
| | - Daniel K Sodickson
- Center for Advanced Imaging Innovation and Research and the Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 First Ave, Fourth Floor, New York, NY, 10016, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, 550 First Avenue, New York, NY, 10016, USA.,NYU WIRELESS, 2 Metro Tech Center, Brooklyn, NY, 11201, USA
| | - Riccardo Lattanzi
- Center for Advanced Imaging Innovation and Research and the Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 First Ave, Fourth Floor, New York, NY, 10016, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, 550 First Avenue, New York, NY, 10016, USA.,NYU WIRELESS, 2 Metro Tech Center, Brooklyn, NY, 11201, USA
| |
Collapse
|
25
|
Rupprecht S, Sica CT, Chen W, Lanagan MT, Yang QX. Improvements of transmit efficiency and receive sensitivity with ultrahigh dielectric constant (uHDC) ceramics at 1.5 T and 3 T. Magn Reson Med 2017; 79:2842-2851. [PMID: 28948637 DOI: 10.1002/mrm.26943] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Revised: 08/09/2017] [Accepted: 09/01/2017] [Indexed: 12/11/2022]
Abstract
PURPOSE Incorporating high dielectric constant (HDC) materials into radiofrequency (RF) coils has been shown to effectively improve RF coil performance at 7 and 3 T because of the induced displacement current in the high dielectric constant materials. The displacement current is proportional to the RF field frequency and permittivity of the material. The aim of this paper is to investigate the effect of high dielectric constant materials with even greater permittivity on the RF field at 1.5 T and 3 T. METHODS Several monolithic ceramic materials with an ultrahigh dielectric constant ranging from 1200 to 3300 were investigated at 1.5 T and 3 T with phantom and human brain imaging along with computer modeling. RESULTS Experimental measurements in phantom studies showed a significant enhancement of signal-to-noise ratio (50-100%) and strong transmission power reduction (3-27-fold). Under suboptimal experimental conditions in this study, the signal-to-noise ratio in the human brain cortex was nearly doubled, which produced high-resolution image without the associated stronger magnetic susceptibility artifacts and elevated specific absorption rate concerns at higher field strengths. CONCLUSIONS Use of ultrahigh dielectric constant ceramic materials is a simple and low-cost approach that could further improve the RF technology to maximize image signal-to-noise ratio and reduce RF energy deposition for human studies. Magn Reson Med 79:2842-2851, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Sebastian Rupprecht
- Pennsylvania State College of Medicine, Department of Radiology, Hershey, Pennsylvania, USA
| | - Christopher T Sica
- Pennsylvania State College of Medicine, Department of Radiology, Hershey, Pennsylvania, USA
| | - Wei Chen
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Michael T Lanagan
- The Pennsylvania State University, Department of Engineering, Science and Mechanics, University Park, Pennsylvania, USA
| | - Qing X Yang
- Pennsylvania State College of Medicine, Department of Radiology, Hershey, Pennsylvania, USA.,Pennsylvania State College of Medicine, Department of Neurosurgery, Hershey, Pennsylvania, USA
| |
Collapse
|
26
|
Abstract
OBJECTIVE To evaluate the ability of ultra-high-field magnetic resonance imaging (UHF-MRI) at 11.7 T to visualize membranous structures of the human inner ear. SPECIMENS Three temporal bones were extracted from cadaveric human heads for use with small-bore UHF-MRI. INTERVENTION Ex vivo cadaveric temporal bone specimens were imaged using an 11.7 T magnetic resonance imaging (MRI) scanner via T1- and T2-weighted-imaging with and without contrast. MAIN OUTCOME MEASURE Qualitative visualization of membranous components of the inner ear compared with reports of UHF-MRI at lower field strengths. RESULTS The membranous anatomy of the inner ear was superbly visualized at 11.7 T. In the cochlea, Reissner's membrane, the scala media, and the basilar membrane were clearly shown on the scan. In the vestibular labyrinth, the wedge-shaped crista ampullaris and the maculae of both the saccule and utricle were visible. Details of the endolymphatic sac and duct were also demonstrated. CONCLUSION To our knowledge, this report presents the first images of the ex vivo human inner ear using 11.7 T UHF-MRI, offering near-histologic resolution. Increased field strength may be particularly useful when imaging the delicate membranous anatomy of the inner ear. Further research on the use of UHF-MRI in clinical and research settings could illuminate structural changes associated with inner ear disorders.
Collapse
|
27
|
O'Reilly TPA, Ruytenberg T, Webb AG. Modular transmit/receive arrays using very-high permittivity dielectric resonator antennas. Magn Reson Med 2017. [PMID: 28635034 PMCID: PMC5811774 DOI: 10.1002/mrm.26784] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
PURPOSE Dielectric resonator antenna (DRAs) are compact structures that exhibit low coupling between adjacent elements and therefore can be used as MRI transmit arrays. In this study, we use very high permittivity materials to construct modular flexible transceive arrays of a variable numbers of elements for operation at 7T. METHODS DRAs were constructed using rectangular blocks of ceramic (lead zirconate titanate, εr = 1070) with the transverse electric (TE)01 mode tuned to 298 MHz. Finite-difference time-domain simulations were used to determine the B1 and specific absorption rate distributions. B1+ maps were acquired in a phantom to validate the simulations. Performance was compared to an equally sized surface coil. In vivo images were acquired of the wrist (four elements), ankle (seven elements), and calf muscle (16 elements). RESULTS Coupling between DRAs spaced 5 mm apart on a phantom was -18.2 dB compared to -9.1 dB for equivalently spaced surface coils. DRAs showed a higher B1+ intensity close to the antenna but a lower penetration depth compared to the surface coil. CONCLUSION DRAs show very low coupling compared to equally sized surface coils and can be used in transceive arrays without requiring decoupling networks. The penetration depth of the current DRA geometry means they are ideally suited to imaging of extremities. Magn Reson Med 79:1781-1788, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Collapse
Affiliation(s)
- Thomas P A O'Reilly
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Thomas Ruytenberg
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew G Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
28
|
Neves AL, Leroi L, Raolison Z, Cochinaire N, Letertre T, Abdeddaïm R, Enoch S, Wenger J, Berthelot J, Adenot-Engelvin AL, Malléjac N, Mauconduit F, Vignaud A, Sabouroux P. Compressed perovskite aqueous mixtures near their phase transitions show very high permittivities: New prospects for high-field MRI dielectric shimming. Magn Reson Med 2017; 79:1753-1765. [DOI: 10.1002/mrm.26771] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 05/05/2017] [Accepted: 05/07/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Ana L. Neves
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
- Centre Commun de Ressources en Micro-ondes, IUSTI - Tech. de Château-Gombert; Marseille France
| | - Lisa Leroi
- CEA, DRF/ISVJF/Neurospin/UNIRS; Université Paris-Saclay; Gif-sur-Yvette Cedex France
| | - Zo Raolison
- CEA, DRF/ISVJF/Neurospin/UNIRS; Université Paris-Saclay; Gif-sur-Yvette Cedex France
| | - Nicolas Cochinaire
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
| | - Thibaut Letertre
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
| | - Redha Abdeddaïm
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
| | - Stefan Enoch
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
| | - Jerome Wenger
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
| | - Johann Berthelot
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
| | | | | | | | - Alexandre Vignaud
- CEA, DRF/ISVJF/Neurospin/UNIRS; Université Paris-Saclay; Gif-sur-Yvette Cedex France
| | - Pierre Sabouroux
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel; Marseille France
| |
Collapse
|
29
|
Koolstra K, Börnert P, Brink W, Webb A. Improved image quality and reduced power deposition in the spine at 3 T using extremely high permittivity materials. Magn Reson Med 2017; 79:1192-1199. [PMID: 28543615 PMCID: PMC5811912 DOI: 10.1002/mrm.26721] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 03/06/2017] [Accepted: 03/27/2017] [Indexed: 11/22/2022]
Abstract
Purpose To explore the effect of using extremely high permittivity (εr∼1,000) materials on image quality and power requirements of spine imaging at 3 T. Theory and Methods A linear array of high permittivity dielectric blocks made of lead zirconate titanate (PZT) was designed and characterized by electromagnetic simulations and experiments. Their effect on the transmit efficiency, receive sensitivity, power deposition, and diagnostic image quality was analyzed in vivo in 10 healthy volunteers. Results Simulation results showed that for quadrature mode excitation, the PZT blocks improve the transmit efficiency by 75% while reducing the maximum 10g average specific absorption rate (SAR10) by 20%. In vivo experiments in 10 healthy volunteers showed statistically significant improvements for the transmit efficiency, and image quality. Compared to active radiofrequency shimming, image quality was similar, but the required system input power was significantly lower for quadrature excitation using the PZT blocks. Conclusion For single‐channel transmit systems, using high permittivity PZT blocks offer a way to improve transmit efficiency and image quality in the spine. Results show that the effect, and therefore optimal design, is body mass index and sex specific. Magn Reson Med 79:1192–1199, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Collapse
Affiliation(s)
- Kirsten Koolstra
- C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Peter Börnert
- C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Wyger Brink
- C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew Webb
- C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
30
|
Kraff O, Quick HH. 7T: Physics, safety, and potential clinical applications. J Magn Reson Imaging 2017; 46:1573-1589. [DOI: 10.1002/jmri.25723] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Accepted: 03/17/2017] [Indexed: 12/19/2022] Open
Affiliation(s)
- Oliver Kraff
- Erwin L. Hahn Institute for MR Imaging; University of Duisburg-Essen; Essen Germany
| | - Harald H. Quick
- Erwin L. Hahn Institute for MR Imaging; University of Duisburg-Essen; Essen Germany
- High Field and Hybrid MR Imaging; University Hospital Essen; Essen Germany
| |
Collapse
|
31
|
Van Gemert J, Brink W, Webb A, Remis R. An Efficient Methodology for the Analysis of Dielectric Shimming Materials in Magnetic Resonance Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:666-673. [PMID: 27831868 DOI: 10.1109/tmi.2016.2624507] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Interference effects in the transmit B1+ field can severely degrade the image quality in high-field Magnetic Resonance Imaging (MRI). High-permittivity pads are increasingly used to counteract these effects, but designing such pads is not trivial. In this paper, we present an efficient solution methodology for this dielectric RF shimming problem. By exploiting the fact that dielectric pads form a low rank perturbation of a large-scale background model, we are able to efficiently compute B1+ fields that correspond to a wide range of different pad realizations. This allows us to efficiently design dielectric pads that eliminate the B1+ -interference effects of high-field MRI. We show that significant speed up factors can be achieved compared with traditional field simulation approaches and we validate our approach against measurements. Measured and simulated field responses are in good agreement with each other indicating that the proposed solution methodology enables us to efficiently analyze dielectric pads in realistic MRI measurement settings.
Collapse
|
32
|
Kuhn FP, Spinner G, Del Grande F, Wyss M, Piccirelli M, Erni S, Pfister P, Ho M, Sah BR, Filli L, Ettlin DA, Gallo LM, Andreisek G, Manoliu A. MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T. Dentomaxillofac Radiol 2016; 46:20160280. [PMID: 27704872 DOI: 10.1259/dmfr.20160280] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
OBJECTIVES To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. METHODS Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. RESULTS TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). CONCLUSIONS MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T.
Collapse
Affiliation(s)
- Felix P Kuhn
- 1 Institute for Diagnostic and Interventional Radiology, Department of Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Georg Spinner
- 2 Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland
| | - Filippo Del Grande
- 3 Department of Diagnostic and Interventional Radiology, Ospedale Regionale di Lugano, Lugano, Switzerland
| | - Michael Wyss
- 2 Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland
| | - Marco Piccirelli
- 4 Department of Neuroradiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Stefan Erni
- 5 Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Pascal Pfister
- 1 Institute for Diagnostic and Interventional Radiology, Department of Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Michael Ho
- 1 Institute for Diagnostic and Interventional Radiology, Department of Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Bert-Ram Sah
- 1 Institute for Diagnostic and Interventional Radiology, Department of Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Lukas Filli
- 1 Institute for Diagnostic and Interventional Radiology, Department of Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Dominik A Ettlin
- 5 Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Luigi M Gallo
- 5 Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Gustav Andreisek
- 1 Institute for Diagnostic and Interventional Radiology, Department of Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Andrei Manoliu
- 1 Institute for Diagnostic and Interventional Radiology, Department of Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.,2 Institute for Biomedical Engineering, University of Zurich and ETH Zurich, Zurich, Switzerland.,6 Psychiatric University Hospital, Department of Psychiatry, Psychotherapy and Psychosomatics, University of Zurich, Zurich, Switzerland
| |
Collapse
|
33
|
O'Reilly TPA, Webb AG, Brink WM. Practical improvements in the design of high permittivity pads for dielectric shimming in neuroimaging at 7T. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2016; 270:108-114. [PMID: 27434779 DOI: 10.1016/j.jmr.2016.07.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2016] [Revised: 06/15/2016] [Accepted: 07/08/2016] [Indexed: 06/06/2023]
Abstract
Improvements are proposed for practical design and use of high permittivity materials in high field neuroimaging in three different areas: (i) a simple formula to predict the permittivity of tri-component aqueous-based perovskite suspensions with relative permittivities between 110 and 300, (ii) characterization of addition of a hydroxyethyl-cellulose gelling agent to improve the long-term stability and material properties of "dielectric pads", and (iii) investigation of the integration of, for example, headphones into the dielectric pads to increase patient comfort within tightly-fitting receive coil arrays.
Collapse
Affiliation(s)
- T P A O'Reilly
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
| | - A G Webb
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands.
| | - W M Brink
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
34
|
Schmidt R, Webb A. Improvements in RF Shimming in High Field MRI Using High Permittivity Materials With Low Order Pre-Fractal Geometries. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:1837-1844. [PMID: 26890643 DOI: 10.1109/tmi.2016.2531120] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Ultra-high field MRI is an area of great interest for clinical research and basic science due to the increased signal-to-noise, spatial resolution and magnetic-susceptibility-based contrast. However, the fact that the electromagnetic wavelength in tissue is comparable to the relevant body dimensions means that the uniformity of the excitation field is much poorer than at lower field strengths. In addition to techniques such as transmit arrays, one simple but effective method to counteract this effect is to use high permittivity "pads". Very high permittivities enable thinner, flexible pads to be used, but the limiting factor is wavelength effects within the pads themselves, which can lead to image artifacts. So far, all studies have used simple continuous rectangular/circular pad geometries. In this work we investigate how the wavelength effects can be partially mitigated utilizing shaped pad with holes. Several arrangements have been simulated, including low order pre-fractal geometries, which maintain the overall coverage of the pad, but can provide better image homogeneity in the region of interest or higher sensitivity depending on the setup. Experimental data in the form of in vivo human images at 7T were acquired to validate the simulation results.
Collapse
|
35
|
Compter I, Peerlings J, Eekers DBP, Postma AA, Ivanov D, Wiggins CJ, Kubben P, Küsters B, Wesseling P, Ackermans L, Schijns OEMG, Lambin P, Hoffmann AL. Technical feasibility of integrating 7 T anatomical MRI in image-guided radiotherapy of glioblastoma: a preparatory study. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 29:591-603. [DOI: 10.1007/s10334-016-0534-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Revised: 02/03/2016] [Accepted: 02/10/2016] [Indexed: 10/22/2022]
|
36
|
Magnetic Resonance Imaging of the Temporomandibular Joint at 7.0 T Using High-Permittivity Dielectric Pads. Invest Radiol 2015; 50:843-9. [DOI: 10.1097/rli.0000000000000196] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
37
|
High-permittivity thin dielectric padding improves fresh blood imaging of femoral arteries at 3 T. Invest Radiol 2015; 50:101-7. [PMID: 25329606 DOI: 10.1097/rli.0000000000000106] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Fresh blood imaging (FBI) is a useful noncontrast magnetic resonance angiographic (MRA) method for the assessment of peripheral arterial disease, particularly for imaging patients with poor renal function. Compared with 1.5 T, 3 T enables higher signal-to-noise ratio and/or spatiotemporal resolution in FBI. Indeed, previous studies have reported successful FBI of the calf station at 3 T. However, FBI of the thigh station at 3 T has been reported to suffer from signal void in the common femoral artery of 1 thigh only because of the radial symmetry in transmit radiofrequency field (B1+) variation. We sought to increase the signal of femoral artery in FBI at 3 T using high-permittivity dielectric padding. MATERIALS AND METHODS We performed FBI and B1+ mapping of the thigh station at 3 T in 13 human subjects to compare the following 3 dielectric padding settings: no padding, commercially available thick (approximately 5 cm) dielectric padding, and high-permittivity thin (approximately 2 cm) dielectric padding. We characterized the radial symmetry in B1+ variation as well as its impact on the FBI signal at baseline and how dielectric padding improves B1+ and FBI. We evaluated the quality of 3 FBI MRA acquisitions using quantitative (ie, contrast-to-noise ratio of femoral arteries) and qualitative (ie, conspicuity of femoral arteries) analyses. RESULTS With the subjects positioned on the magnetic resonance table in feet-first, supine orientation, the radial symmetry in B1+ variation attenuates the signal in the right common femoral artery. The signal void can be improved partially with commercial padding and improved further with high-permittivity padding. Averaging the results over the 13 subjects, the mean B1+, contrast-to-noise ratio, and conspicuity scores for the right common femoral artery were significantly higher with high-permittivity padding than with commercial padding and baseline (P < 0.001). CONCLUSIONS Our study shows that high-permittivity dielectric padding can be used to increase the signal of femoral artery in FBI at 3 T.
Collapse
|
38
|
|
39
|
Brink WM, Remis RF, Webb AG. A theoretical approach based on electromagnetic scattering for analysing dielectric shimming in high-field MRI. Magn Reson Med 2015; 75:2185-94. [PMID: 26125996 DOI: 10.1002/mrm.25783] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 04/15/2015] [Accepted: 05/02/2015] [Indexed: 11/12/2022]
Abstract
PURPOSE In this study, we analyzed dielectric shimming by formulating it as an electromagnetic scattering problem using integral equations. METHODS Three-dimensional simulations of the radiofrequency field in two configurations using different materials were analyzed in terms of induced currents and secondary fields. A two-dimensional integral equation method with different backgrounds was used to identify the underlying physical mechanisms. This framework was then used to develop an inversion method for the design of dielectric pads. RESULTS The effects of a dielectric pad can be attributed to the interference of a secondary field that is produced by the currents induced in the dielectric pad, radiating in an inhomogeneous background. The integral equation method with inhomogeneous background reduces the complexity of the forward and inverse problem significantly and can be used to optimize the permittivity distribution for a desired B1+ field. Agreement with experimental B1+ maps was obtained in a cylindrical phantom, demonstrating the validity of the method. CONCLUSIONS The integral equation method with inhomogeneous background yields an efficient numerical framework for the analysis and inverse design of dielectric shimming materials.
Collapse
Affiliation(s)
- Wyger M Brink
- C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
| | - Rob F Remis
- Circuits and Systems Group, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, Netherlands
| | - Andrew G Webb
- C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
40
|
|
41
|
van der Jagt MA, Brink WM, Versluis MJ, Steens SCA, Briaire JJ, Webb AG, Frijns JHM, Verbist BM. Visualization of human inner ear anatomy with high-resolution MR imaging at 7T: initial clinical assessment. AJNR Am J Neuroradiol 2014; 36:378-83. [PMID: 25147195 DOI: 10.3174/ajnr.a4084] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE In many centers, MR imaging of the inner ear and auditory pathway performed on 1.5T or 3T systems is part of the preoperative work-up of cochlear implants. We investigated the applicability of clinical inner ear MR imaging at 7T and compared the visibility of inner ear structures and nerves within the internal auditory canal with images acquired at 3T. MATERIALS AND METHODS Thirteen patients with sensorineural hearing loss eligible for cochlear implantation underwent examinations on 3T and 7T scanners. Two experienced head and neck radiologists evaluated the 52 inner ear datasets. Twenty-four anatomic structures of the inner ear and 1 overall score for image quality were assessed by using a 4-point grading scale for the degree of visibility. RESULTS The visibility of 11 of the 24 anatomic structures was rated higher on the 7T images. There was no significant difference in the visibility of 13 anatomic structures and the overall quality rating. A higher incidence of artifacts was observed in the 7T images. CONCLUSIONS The gain in SNR at 7T yielded a more detailed visualization of many anatomic structures, especially delicate ones, despite the challenges accompanying MR imaging at a high magnetic field.
Collapse
Affiliation(s)
- M A van der Jagt
- From the Departments of Otorhinolaryngology (M.A.v.d.J., J.J.B., J.H.M.F.)
| | - W M Brink
- Radiology (W.M.B., M.J.V., A.G.W., B.M.V.) C.J. Gorter Center for High-Field MRI (W.M.B., M.J.V., A.G.W.)
| | - M J Versluis
- Radiology (W.M.B., M.J.V., A.G.W., B.M.V.) C.J. Gorter Center for High-Field MRI (W.M.B., M.J.V., A.G.W.)
| | - S C A Steens
- Department of Radiology (S.C.A.S., B.M.V.), Radboud University Medical Center, Nijmegen, the Netherlands
| | - J J Briaire
- From the Departments of Otorhinolaryngology (M.A.v.d.J., J.J.B., J.H.M.F.)
| | - A G Webb
- Radiology (W.M.B., M.J.V., A.G.W., B.M.V.) C.J. Gorter Center for High-Field MRI (W.M.B., M.J.V., A.G.W.)
| | - J H M Frijns
- From the Departments of Otorhinolaryngology (M.A.v.d.J., J.J.B., J.H.M.F.) Leiden Institute for Brain and Cognition (J.H.M.F.), Leiden University Medical Center, Leiden, the Netherlands
| | - B M Verbist
- Radiology (W.M.B., M.J.V., A.G.W., B.M.V.) Department of Radiology (S.C.A.S., B.M.V.), Radboud University Medical Center, Nijmegen, the Netherlands
| |
Collapse
|