1
|
Sharma SP, van der Bie J, van Straten M, Hirsch A, Bos D, Dijkshoorn ML, Booij R, Budde RPJ. Coronary calcium scoring on virtual non-contrast and virtual non-iodine reconstructions compared to true non-contrast images using photon-counting computed tomography. Eur Radiol 2024; 34:3699-3707. [PMID: 37940711 PMCID: PMC11166815 DOI: 10.1007/s00330-023-10402-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 08/17/2023] [Accepted: 09/17/2023] [Indexed: 11/10/2023]
Abstract
OBJECTIVES To compare coronary artery calcification (CAC) scores measured on virtual non-contrast (VNC) and virtual non-iodine (VNI) reconstructions computed from coronary computed tomography angiography (CCTA) using photon-counting computed tomography (PCCT) to true non-contrast (TNC) images. METHODS We included 88 patients (mean age = 59 years ± 13.5, 69% male) who underwent a TNC coronary calcium scan followed by CCTA on PCCT. VNC images were reconstructed in 87 patients and VNI in 88 patients by virtually removing iodine from the CCTA images. For all reconstructions, CAC scores were determined, and patients were classified into risk categories. The overall agreement of the reconstructions was analyzed by Bland-Altman plots and the level of matching classifications. RESULTS The median CAC score on TNC was 27.8 [0-360.4] compared to 8.5 [0.2-101.6] (p < 0.001) on VNC and 72.2 [1.3-398.8] (p < 0.001) on VNI. Bland-Altman plots depicted a bias of 148.8 (ICC = 0.82, p < 0.001) and - 57.7 (ICC = 0.95, p < 0.001) for VNC and VNI, respectively. Of all patients with CACTNC = 0, VNC reconstructions scored 63% of the patients correctly, while VNI scored 54% correctly. Of the patients with CACTNC > 0, VNC and VNI reconstructions detected the presence of coronary calcium in 90% and 92% of the patients. CACVNC tended to underestimate CAC score, whereas CACVNI overestimated, especially in the lower risk categories. According to the risk categories, VNC misclassified 55% of the patients, while VNI misclassified only 32%. CONCLUSION Compared to TNC images, VNC underestimated and VNI overestimated the actual CAC scores. VNI reconstructions quantify and classify coronary calcification scores more accurately than VNC reconstructions. CLINICAL RELEVANCE STATEMENT Photon-counting CT enables spectral imaging, which might obviate the need for non-contrast enhanced coronary calcium scoring, but optimization is necessary for the clinical implementation of the algorithms. KEY POINTS • Photon-counting computed tomography uses spectral information to virtually remove the signal of contrast agents from contrast-enhanced scans. • Virtual non-contrast reconstructions tend to underestimate coronary artery calcium scores compared to true non-contrast images, while virtual non-iodine reconstructions tend to overestimate the calcium scores. • Virtual non-iodine reconstructions might obviate the need for non-contrast enhanced calcium scoring, but optimization is necessary for the clinical implementation of the algorithms.
Collapse
Affiliation(s)
- Simran P Sharma
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
- Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Judith van der Bie
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Marcel van Straten
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Alexander Hirsch
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
- Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Daniel Bos
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
- Department of Epidemiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Marcel L Dijkshoorn
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Ronald Booij
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
| |
Collapse
|
2
|
Dobrolinska MM, Koetzier LR, Greuter MJW, Vliegenthart R, van der Bie J, Prakken NHJ, Slart RHJA, Leiner T, Budde RPJ, Mastrodicasa D, Booij R, Fleischmann D, Willemink MJ, van Straten M, van der Werf NR. Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study. Eur Radiol 2024:10.1007/s00330-024-10806-4. [PMID: 38789792 DOI: 10.1007/s00330-024-10806-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 03/23/2024] [Accepted: 04/05/2024] [Indexed: 05/26/2024]
Abstract
BACKGROUND The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on photon counting CT (PCCT) for coronary artery calcium (CAC) scoring, and second, to assess the feasibility of calculating CAC scores from CCTA, in comparison to reference calcium scoring CT (CSCT) scans. METHODS In this phantom study, an artificial coronary artery was translated at velocities corresponding to 0, < 60, and 60-75 beats per minute (bpm) within an anthropomorphic phantom. The density of calcifications was 100 (very low), 200 (low), 400 (medium), and 800 (high) mgHA/cm3, respectively. CCTA was reconstructed with the following parameters: virtual non-iodine (VNI), with and without iterative reconstruction (QIR level 2, QIR off, respectively); kernels Qr36 and Qr44f; slice thickness/increment 3.0/1.5 mm and 0.4/0.2 mm. The agreement in risk group classification between CACCCTA and CACCSCT scoring was measured using Cohen weighted linear κ with 95% CI. RESULTS For CCTA reconstructed with 0.4 mm slice thickness, calcium detectability was perfect (100%). At < 60 bpm, CACCCTA of low, and medium density calcification was underestimated by 53%, and 15%, respectively. However, CACCCTA was not significantly different from CACCSCT of very low, and high-density calcifications. The best risk agreement was achieved when CCTA was reconstructed with QIR off, Qr44f, and 0.4 mm slice thickness (κ = 0.762, 95% CI 0.671-0.853). CONCLUSION In this dynamic phantom study, the detection of calcifications with different densities was excellent with CCTA on PCCT using thin-slice VNI reconstruction. Agatston scores were underestimated compared to CSCT but agreement in risk classification was substantial. CLINICAL RELEVANCE STATEMENT Photon counting CT may enable the implementation of coronary artery calcium scoring from coronary CTA in daily clinical practice. KEY POINTS Photon-counting CTA allows for excellent detectability of low-density calcifications at all heart rates. Coronary artery calcium scoring from coronary CTA acquired on photon counting CT is feasible, although improvement is needed. Adoption of the standard acquisition and reconstruction protocol for calcium scoring is needed for improved quantification of coronary artery calcium to fully employ the potential of photon counting CT.
Collapse
Affiliation(s)
- Magdalena M Dobrolinska
- Department of Radiology and Nuclear Medicine Rotterdam, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Medical Imaging Center, Groningen, The Netherlands.
| | - Lennart R Koetzier
- Department of Radiology and Nuclear Medicine Rotterdam, Erasmus MC University Medical Center, Rotterdam, The Netherlands
- Department of Radiology Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Marcel J W Greuter
- Department of Radiology, University of Groningen, University Medical Center Groningen, Medical Imaging Center, Groningen, The Netherlands
| | - Rozemarijn Vliegenthart
- Department of Radiology, University of Groningen, University Medical Center Groningen, Medical Imaging Center, Groningen, The Netherlands
| | - Judith van der Bie
- Department of Radiology and Nuclear Medicine Rotterdam, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Niek H J Prakken
- Department of Radiology, University of Groningen, University Medical Center Groningen, Medical Imaging Center, Groningen, The Netherlands
| | - Riemer H J A Slart
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Medical Imaging Center, Groningen, The Netherlands
| | - Tim Leiner
- Department of Radiology Rochester, Mayo Clinic, Rochester, MN, USA
| | - Ricardo P J Budde
- Department of Radiology and Nuclear Medicine Rotterdam, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Domenico Mastrodicasa
- Department of Radiology Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Ronald Booij
- Department of Radiology and Nuclear Medicine Rotterdam, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Dominik Fleischmann
- Department of Radiology Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Martin J Willemink
- Department of Radiology Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Marcel van Straten
- Department of Radiology and Nuclear Medicine Rotterdam, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Niels R van der Werf
- Department of Radiology and Nuclear Medicine Rotterdam, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
3
|
McDermott MC, Sartoretti T, Stammen L, Martens B, Jost G, Pietsch H, Gutjahr R, Schmidt B, Flohr TG, Alkadhi H, Wildberger JE. Countering Calcium Blooming With Personalized Contrast Media Injection Protocols: The 1-2-3 Rule for Photon-Counting Detector CCTA. Invest Radiol 2024:00004424-990000000-00217. [PMID: 38742928 DOI: 10.1097/rli.0000000000001078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
OBJECTIVE Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. MATERIALS AND METHODS A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. RESULTS Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. CONCLUSIONS This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.
Collapse
Affiliation(s)
- Michael C McDermott
- From the Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands (M.C.M., T.S., L.S., B.M., T.G.F., J.E.W.); Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (T.S., H.A.); Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, the Netherlands (M.C.M., T.S., L.S., B.M., J.E.W.); Bayer AG, Berlin, Germany (M.C.M., G.J., H.P.); and Computed Tomography Division, Siemens Healthineers AG, Forchheim, Germany (R.G., B.S., T.G.F.)
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Breiding PS, Gomollon AMT, Martini K, Nakhostin D, Alkadhi H, Euler A. Photon-Counting Detector CT for Kidney Stone Detection in Excretory Phase CT-Comparison Between Virtual Non-contrast and Virtual Non-iodine Reconstructions in a 3D Printed Kidney Phantom. Acad Radiol 2024:S1076-6332(24)00209-5. [PMID: 38641450 DOI: 10.1016/j.acra.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 03/24/2024] [Accepted: 04/04/2024] [Indexed: 04/21/2024]
Abstract
RATIONALE AND OBJECTIVES To evaluate and compare the effectiveness of contrast media subtraction and kidney stone detection between a virtual non-iodine reconstruction algorithm (VNI; PureCalcium) and a virtual non-contrast (VNC) algorithm in excretory phase photon-counting detector computed tomography (PCD-CT), using a 3D printed kidney phantom under various tube voltages and radiation doses. MATERIALS AND METHODS A 3D-printed kidney phantom, holding Calcium Oxalate (CaOx) and uric acid stones within contrast-enhanced calyces, was created. The calyx density mirrored the average density observed in 200 excretory phase patients (916 HU at 110 kV). Imaging was conducted on a clinical dual-source PCD-CT at 120 kV and 140 kV, with radiation doses set at 5, 10, and 15 mGy. VNI and VNC algorithms were applied. Two blinded readers evaluated the image quality, along with the degree of contrast media and kidney stone subtraction, using visual scales. Krippendorff's alpha was calculated to determine inter-reader agreement, and the Chi-squared test was employed for comparing ordinal data. RESULTS Reader 2 rated overall image quality higher for VNI than VNC (4.90 vs. 4.00; P < .05), while Reader 1 found no significant difference (4.96 vs. 5.00; P > .05). Substantial agreement was observed between readers for contrast media subtraction in both VNC and VNI (Krippendorff's alpha range: 0.628-0.748). Incomplete contrast media subtraction occurred more frequently with VNI for both readers (Reader 1: 29% vs. 15%; P < .05; Reader 2: 24% vs. 20%; P > .05). Uric acid and smaller stones (<5 mm) were more likely to be subtracted than CaOx and larger stones in both VNC and VNI. Overall, a higher rate of stone subtraction was noted with VNI compared to VNC (Reader 1: 22% vs. 16%; Reader 2: 25% vs. 10%; P < .05). Neither radiation dose nor tube voltage significantly influenced stone subtraction (P > .05). CONCLUSION VNC demonstrated greater accuracy than VNI for contrast media subtraction and kidney stone visibility. Radiation dose and tube voltage had no significant impact. Nonetheless, both algorithms still exhibited frequent incomplete contrast media subtraction and partial kidney stone subtraction.
Collapse
Affiliation(s)
- Philipe S Breiding
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; University Institute of Diagnostic and Interventional Neuroradiology, Inselspital, University of Bern, Bern, Switzerland
| | - Ana Maria Turrion Gomollon
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Katharina Martini
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Dominik Nakhostin
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - André Euler
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland; Department of Radiology, Kantonsspital Baden, Baden, Switzerland.
| |
Collapse
|
5
|
Meloni A, Maffei E, Clemente A, De Gori C, Occhipinti M, Positano V, Berti S, La Grutta L, Saba L, Cau R, Bossone E, Mantini C, Cavaliere C, Punzo B, Celi S, Cademartiri F. Spectral Photon-Counting Computed Tomography: Technical Principles and Applications in the Assessment of Cardiovascular Diseases. J Clin Med 2024; 13:2359. [PMID: 38673632 PMCID: PMC11051476 DOI: 10.3390/jcm13082359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/15/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024] Open
Abstract
Spectral Photon-Counting Computed Tomography (SPCCT) represents a groundbreaking advancement in X-ray imaging technology. The core innovation of SPCCT lies in its photon-counting detectors, which can count the exact number of incoming x-ray photons and individually measure their energy. The first part of this review summarizes the key elements of SPCCT technology, such as energy binning, energy weighting, and material decomposition. Its energy-discriminating ability represents the key to the increase in the contrast between different tissues, the elimination of the electronic noise, and the correction of beam-hardening artifacts. Material decomposition provides valuable insights into specific elements' composition, concentration, and distribution. The capability of SPCCT to operate in three or more energy regimes allows for the differentiation of several contrast agents, facilitating quantitative assessments of elements with specific energy thresholds within the diagnostic energy range. The second part of this review provides a brief overview of the applications of SPCCT in the assessment of various cardiovascular disease processes. SPCCT can support the study of myocardial blood perfusion and enable enhanced tissue characterization and the identification of contrast agents, in a manner that was previously unattainable.
Collapse
Affiliation(s)
- Antonella Meloni
- Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.)
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Erica Maffei
- Department of Radiology, Istituto di Ricovero e Cura a Carattere Scientifico SYNLAB SDN, 80131 Naples, Italy; (E.M.); (C.C.); (B.P.)
| | - Alberto Clemente
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Carmelo De Gori
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Mariaelena Occhipinti
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Vicenzo Positano
- Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.)
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Sergio Berti
- Diagnostic and Interventional Cardiology Department, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Ludovico La Grutta
- Department of Radiology, University Hospital “P. Giaccone”, 90127 Palermo, Italy;
| | - Luca Saba
- Department of Radiology, University Hospital of Cagliari, 09042 Monserrato (CA), Italy; (L.S.); (R.C.)
| | - Riccardo Cau
- Department of Radiology, University Hospital of Cagliari, 09042 Monserrato (CA), Italy; (L.S.); (R.C.)
| | - Eduardo Bossone
- Department of Cardiology, Ospedale Cardarelli, 80131 Naples, Italy;
| | - Cesare Mantini
- Department of Radiology, “G. D’Annunzio” University, 66100 Chieti, Italy;
| | - Carlo Cavaliere
- Department of Radiology, Istituto di Ricovero e Cura a Carattere Scientifico SYNLAB SDN, 80131 Naples, Italy; (E.M.); (C.C.); (B.P.)
| | - Bruna Punzo
- Department of Radiology, Istituto di Ricovero e Cura a Carattere Scientifico SYNLAB SDN, 80131 Naples, Italy; (E.M.); (C.C.); (B.P.)
| | - Simona Celi
- BioCardioLab, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Filippo Cademartiri
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| |
Collapse
|
6
|
Cui M, Bao S, Li J, Dong H, Xu Z, Yan F, Yang W. CT radiomic features reproducibility of virtual non-contrast series derived from photon-counting CCTA datasets using a novel calcium-preserving reconstruction algorithm compared with standard non-contrast series: focusing on epicardial adipose tissue. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2024:10.1007/s10554-024-03096-w. [PMID: 38587689 DOI: 10.1007/s10554-024-03096-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 03/26/2024] [Indexed: 04/09/2024]
Abstract
PURPOSE We aimed to evaluate the reproducibility of computed tomography (CT) radiomic features (RFs) about Epicardial Adipose Tissue (EAT). The features derived from coronary photon-counting computed tomography (PCCT) angiography datasets using the PureCalcium (VNCPC) and conventional virtual non-contrast (VNCConv) algorithm were compared with true non-contrast (TNC) series. METHODS RFs of EAT from 52 patients who underwent PCCT were quantified using VNCPC, VNCConv, and TNC series. The agreement of EAT volume (EATV) and EAT density (EATD) was evaluated using Pearson's correlation coefficient and Bland-Altman analysis. A total of 1530 RFs were included. They are divided into 17 feature categories, each containing 90 RFs. The intraclass correlation coefficients (ICCs) and concordance correlation coefficients (CCCs) were calculated to assess the reproducibility of RFs. The cutoff value considered indicative of reproducible features was > 0.75. RESULTS the VNCPC and VNCConv tended to underestimate EATVs and overestimate EATDs. Both EATV and EATD of VNCPC series showed higher correlation and agreement with TNC than VNCConv series. All types of RFs from VNCPC series showed greater reproducibility than VNCConv series. Across all image filters, the Square filter exhibited the highest level of reproducibility (ICC = 67/90, 74.4%; CCC = 67/90, 74.4%). GLDM_GrayLevelNonUniformity feature had the highest reproducibility in the original image (ICC = 0.957, CCC = 0.958), exhibiting a high degree of reproducibility across all image filters. CONCLUSION The accuracy evaluation of EATV and EATD and the reproducibility of RFs from VNCPC series make it an excellent substitute for TNC series exceeding VNCConv series.
Collapse
Affiliation(s)
- MengXu Cui
- Department of Radiology, Ruijin Hospital affiliated to School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - ShouYu Bao
- Department of Radiology, Ruijin Hospital affiliated to School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - JiQiang Li
- Department of Radiology, Ruijin Hospital affiliated to School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - HaiPeng Dong
- Department of Radiology, Ruijin Hospital affiliated to School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - ZhiHan Xu
- Siemens Healthineers CT Collaboration, Erlangen, Germany
| | - Fuhua Yan
- Department of Radiology, Ruijin Hospital affiliated to School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Wenjie Yang
- Department of Radiology, Ruijin Hospital affiliated to School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
7
|
Risch F, Harmel E, Rippel K, Wein B, Raake P, Girdauskas E, Elvinger S, Owais T, Scheurig-Muenkler C, Kroencke T, Schwarz F, Braun F, Decker JA. Virtual non-contrast series of photon-counting detector computed tomography angiography for aortic valve calcium scoring. Int J Cardiovasc Imaging 2024; 40:723-732. [PMID: 38175389 PMCID: PMC11052824 DOI: 10.1007/s10554-023-03040-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 12/20/2023] [Indexed: 01/05/2024]
Abstract
The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.
Collapse
Affiliation(s)
- Franka Risch
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
| | - Eva Harmel
- Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany
| | - Katharina Rippel
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
| | - Bastian Wein
- Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany
| | - Philip Raake
- Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany
| | - Evaldas Girdauskas
- Department of Cardiac Surgery, University Hospital Augsburg, Augsburg, Germany
| | - Sébastien Elvinger
- Medical Clinic, Department of Cardiology, University Hospital Augsburg, Augsburg, Germany
| | - Tamer Owais
- Department of Cardiac Surgery, University Hospital Augsburg, Augsburg, Germany
| | - Christian Scheurig-Muenkler
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
| | - Thomas Kroencke
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany.
- Centre for Advanced Analytics and Predictive Sciences, Augsburg University, Augsburg, Germany.
| | - Florian Schwarz
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
- Clinic for Diagnostic and Interventional Radiology, Donau-Isar-Klinikum, Deggendorf, Germany
| | - Franziska Braun
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
| | - Josua A Decker
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
| |
Collapse
|
8
|
Sakuma H. Virtual Noncontrast CT for Coronary Artery Calcification Scoring Using Photon-Counting CT. Radiology 2024; 310:e240476. [PMID: 38530180 DOI: 10.1148/radiol.240476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Affiliation(s)
- Hajime Sakuma
- From the Department of Radiology, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie 5148507, Japan
| |
Collapse
|
9
|
Risch F, Schwarz F, Kroencke T, Decker JA. Heart rate sensitivity of virtual non-contrast calcium scores derived from photon counting detector CT data: a phantom study. LA RADIOLOGIA MEDICA 2024; 129:401-410. [PMID: 38319495 PMCID: PMC10943147 DOI: 10.1007/s11547-024-01773-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 01/03/2024] [Indexed: 02/07/2024]
Abstract
PURPOSE To assess the reliability of virtual non-contrast (VNC) derived coronary artery calcium quantities in relation to heart rate and the VNC algorithm used compared to reference true non-contrast (TNC), considering several clinically established acquisition modes. MATERIAL AND METHODS An ad hoc built coronary phantom containing four calcified lesions and an iodinated lumen was scanned using three cardiac acquisition modes three times within an anthropomorphic cardiac motion phantom simulating different heart rates (0, 60, 80, 100 bpm) and reconstructed with a conventional (VNCconv) and a calcium-sensitive (VNCpc) VNC algorithm. TNC reference was scanned at 0 bpm with non-iodinated lumen. Calcium scores were assessed in terms of number of lesions detected, Agatston and volume scores and global noise was measured. Paired t-test and Wilcoxon test were performed to test measurements for significant difference. RESULTS For both VNC algorithms used, calcium levels or noise were not significantly affected by heart rate. Measurements on VNCpc reconstructions best reproduced TNC results, but with increased variability (Agatston scores at 0 bpm for TNC, VNCconv, and VNCpc were 47.1 ± 1.1, 6.7 ± 2.8 (p < 0.001), and 45.3 ± 7.6 (p > 0.05), respectively). VNC reconstructions showed lower noise levels compared to TNC, especially for VNCpc (noiseheart on TNC, VNCconv and VNCpc at 0 bpm was 5.0 ± 0.4, 4.5 ± 0.2, 4.2 ± 0.2). CONCLUSION No significant heart rate dependence of VNC-based calcium scores was observed in an intra-reconstruction comparison. VNCpc reproduces TNC scores better than VNCconv without significant differences and decreased noise, however, with an increasing average deviation with rising heart rates. VNC-based CACS should be used with caution as the measures show higher variability compared to reference TNC and therefore hold the potential of incorrect risk categorization.
Collapse
Affiliation(s)
- Franka Risch
- Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
| | - Florian Schwarz
- Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
- Medical Faculty, Ludwig Maximilian University Munich, Munich, Germany
- Clinic for Diagnostic and Interventional Radiology, Donau-Isar-Klinikum, Deggendorf, Germany
| | - Thomas Kroencke
- Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany.
- Centre for Advanced Analytics and Predictive Sciences (CAAPS), University Augsburg, Augsburg, Germany.
| | - Josua A Decker
- Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany
| |
Collapse
|
10
|
Haag NP, Michael AE, Lennartz S, Panknin C, Niehoff JH, Borggrefe J, Shahzadi I, Zwanenburg A, Kroeger JR. Coronary Artery Calcium Scoring Using Virtual Versus True Noncontrast Images From Photon-Counting Coronary CT Angiography. Radiology 2024; 310:e230545. [PMID: 38530174 DOI: 10.1148/radiol.230545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
Background Coronary artery calcium scoring (CACS) for coronary artery disease requires true noncontrast (TNC) CT alongside contrast-enhanced coronary CT angiography (CCTA). Photon-counting CT provides an algorithm (PureCalcium) for reconstructing virtual noncontrast images from CCTA specifically for CACS. Purpose To assess CACS differences based on PureCalcium images derived from contrast-enhanced photon-counting CCTA compared with TNC images and evaluate the impact of these differences on the clinically relevant classification of patients into plaque burden groups. Materials and Methods Photon-counting CCTA images acquired between August 2022 and May 2023 were retrospectively identified. Agatston scores were derived from both TNC and PureCalcium images and tested for differences with use of the Wilcoxon signed-rank test. The agreement was assessed with use of equivalence tests, Bland-Altman analysis, and intraclass correlation coefficient. Plaque burden groups were established based on Agatston scores, and agreement was evaluated using weighted Cohen kappa. The dose-length product was analyzed. Results Among 170 patients (mean age, 63 years ± 13 [SD]; 92 male), 111 had Agatston scores higher than 0. Median Agatston scores did not differ between TNC and PureCalcium images (4.8 [IQR, 0-84.4; range, 0.0-2151.8] vs 2.7 [IQR, 0-90.7; range, 0.0-2377.1]; P = .99), with strong correlation (intraclass correlation coefficient, 0.98 [95% CI: 0.97, 0.99]). The equivalence test was inconclusive, with a 95% CI of 0.90, 1.19. Bland-Altman analysis showed wide repeatability limits, indicating low agreement between the two scores. With use of the PureCalcium algorithm, 125 of 170 patients (74%) were correctly classified into plaque burden groups (excellent agreement, κ = 0.88). Patients without plaque burden were misclassified at higher than normal rates (P < .001). TNC image acquisition contributed a mean of 19.7% ± 8.8 of the radiation dose of the entire examination. Conclusion PureCalcium images show potential to replace TNC images for measuring Agatston scores, thereby reducing radiation dose in CCTA. There was strong correlation in calcium scores between TNC and PureCalcium, but limited agreement. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Sakuma in this issue.
Collapse
Affiliation(s)
- Nina P Haag
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Arwed E Michael
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Simon Lennartz
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Christoph Panknin
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Julius H Niehoff
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Jan Borggrefe
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Iram Shahzadi
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Alex Zwanenburg
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| | - Jan Robert Kroeger
- From the Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Hans-Nolte-Strasse 1, 32429 Minden, Germany (N.P.H., A.E.M., J.H.N., J.B., J.R.K.); Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany (S.L.); Siemens Healthcare, Erlangen, Germany (C.P., I.S.); and National Center for Tumor Diseases, Dresden, Germany (A.Z.)
| |
Collapse
|
11
|
Wolf EV, Halfmann MC, Varga-Szemes A, Fink N, Kloeckner R, Bockius S, Allmendinger T, Hagenauer J, Koehler T, Kreitner KF, Schoepf UJ, Münzel T, Düber C, Gori T, Yang Y, Hell MM, Emrich T. Photon-Counting Detector CT Virtual Monoenergetic Images for Coronary Artery Stenosis Quantification: Phantom and In Vivo Evaluation. AJR Am J Roentgenol 2024; 222:e2330481. [PMID: 38197760 DOI: 10.2214/ajr.23.30481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
BACKGROUND. Calcium blooming causes stenosis overestimation on coronary CTA. OBJECTIVE. The purpose of this article was to evaluate the impact of virtual monoenergetic imaging (VMI) reconstruction level on coronary artery stenosis quantification using photon-counting detector (PCD) CT. METHODS. A phantom containing two custom-made vessels (representing 25% and 50% stenosis) underwent PCD CT acquisitions without and with simulated cardiac motion. A retrospective analysis was performed of 33 patients (seven women, 26 men; mean age, 71.3 ± 9.0 [SD] years; 64 coronary artery stenoses) who underwent coronary CTA by PCD CT followed by invasive coronary angiography (ICA). Scans were reconstructed at nine VMI energy levels (40-140 keV). Percentage diameter stenosis (PDS) was measured, and bias was determined from the ground-truth stenosis percentage in the phantom and ICA-derived quantitative coronary angiography measurements in patients. Extent of blooming artifact was measured in the phantom and in calcified and mixed plaques in patients. RESULTS. In the phantom, PDS decreased for 25% stenosis from 59.9% (40 keV) to 13.4% (140 keV) and for 50% stenosis from 81.6% (40 keV) to 42.3% (140 keV). PDS showed lowest bias for 25% stenosis at 90 keV (bias, 1.4%) and for 50% stenosis at 100 keV (bias, -0.4%). Blooming artifacts decreased for 25% stenosis from 61.5% (40 keV) to 35.4% (140 keV) and for 50% stenosis from 82.7% (40 keV) to 52.1% (140 keV). In patients, PDS for calcified plaque decreased from 70.8% (40 keV) to 57.3% (140 keV), for mixed plaque decreased from 69.8% (40 keV) to 56.3% (140 keV), and for noncalcified plaque was 46.6% at 40 keV and 54.6% at 140 keV. PDS showed lowest bias for calcified plaque at 100 keV (bias, 17.2%), for mixed plaque at 140 keV (bias, 5.0%), and for noncalcified plaque at 40 keV (bias, -0.5%). Blooming artifacts decreased for calcified plaque from 78.4% (40 keV) to 48.6% (140 keV) and for mixed plaque from 73.1% (40 keV) to 44.7% (140 keV). CONCLUSION. For calcified and mixed plaque, stenosis severity measurements and blooming artifacts decreased at increasing VMI reconstruction levels. CLINICAL IMPACT. PCD CT with VMI reconstruction helps overcome current limitations in stenosis quantification on coronary CTA.
Collapse
Affiliation(s)
- Elias V Wolf
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | - Moritz C Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
- German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
| | - Akos Varga-Szemes
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | - Nicola Fink
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
- Department of Radiology, University Hospital, LMU Munich, München, Germany
| | - Roman Kloeckner
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
- Department for Interventional Radiology, University Hospital of Lübeck, Lübeck, Germany
| | - Stefanie Bockius
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
| | | | | | | | - Karl-Friedrich Kreitner
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
| | - U Joseph Schoepf
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | - Thomas Münzel
- German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
- Department of Cardiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Christoph Düber
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
| | - Tommaso Gori
- German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
- Department of Cardiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Yang Yang
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
| | - Michaela M Hell
- Department of Cardiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Tilman Emrich
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
- German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
| |
Collapse
|
12
|
Feldle P, Scheuber M, Grunz JP, Heidenreich JF, Pannenbecker P, Nora C, Huflage H, Bley TA, Petritsch B. Virtual non-iodine photon-counting CT-angiography for aortic valve calcification scoring. Sci Rep 2024; 14:4724. [PMID: 38413684 PMCID: PMC10899655 DOI: 10.1038/s41598-024-54918-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 02/18/2024] [Indexed: 02/29/2024] Open
Abstract
Photon-counting detector (PCD)-CT allows for reconstruction of virtual non-iodine (VNI) images from contrast-enhanced datasets. This study assesses the diagnostic performance of aortic valve calcification scoring (AVCS) derived from VNI datasets generated with a 1st generation clinical dual-source PCD-CT. AVCS was evaluated in 123 patients (statistical analysis only comprising patients with aortic valve calcifications [n = 56; 63.2 ± 11.6 years]), who underwent contrast enhanced electrocardiogram-gated (either prospective or retrospective or both) cardiac CT on a clinical PCD system. Patient data was reconstructed at 70 keV employing a VNI reconstruction algorithm. True non-contrast (TNC) scans at 70 keV without quantum iterative reconstruction served as reference in all individuals. Subgroup analysis was performed in 17 patients who received both, prospectively and retrospectively gated contrast enhanced scans (n = 8 with aortic valve calcifications). VNI images with prospective/retrospective gating had an overall sensitivity of 69.2%/56.0%, specificity of 100%/100%, accuracy of 85.4%/81.0%, positive predictive value of 100%/100%, and a negative predictive value of 78.2%/75.0%. VNI images with retrospective gating achieved similar results. For both gating approaches, AVCSVNI showed high correlation (r = 0.983, P < 0.001 for prospective; r = 0.986, P < 0.001 for retrospective) with AVCSTNC. Subgroup analyses demonstrated excellent intra-individual correlation between different acquisition modes (r = 0.986, P < 0.001). Thus, VNI images derived from cardiac PCD-CT allow for excellent diagnostic performance in the assessment of AVCS, suggesting potential for the omission of true non-contrast scans in the clinical workup of patients with aortic calcifications.
Collapse
Affiliation(s)
- Philipp Feldle
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany.
| | - Marit Scheuber
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany
| | - Julius F Heidenreich
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany
| | - Pauline Pannenbecker
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany
| | - Conrads Nora
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany
| | - Henner Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany
| | - Thorsten A Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacherstr. 6, 97080, Würzburg, Germany
| | - Bernhard Petritsch
- Department of Diagnostic and Interventional Radiology, Klinikum Klagenfurt am Wörthersee, Feschnigstr. 11, 9020, Klagenfurt am Wörthersee, Austria
| |
Collapse
|
13
|
Mergen V, Rusek S, Civaia F, Rossi P, Rajagopal R, Bättig E, Manka R, Candreva A, Eberhard M, Alkadhi H. Virtual calcium removal in calcified coronary arteries with photon-counting detector CT-first in-vivo experience. Front Cardiovasc Med 2024; 11:1367463. [PMID: 38455720 PMCID: PMC10917906 DOI: 10.3389/fcvm.2024.1367463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 02/09/2024] [Indexed: 03/09/2024] Open
Abstract
Purpose To evaluate the feasibility and accuracy of quantification of calcified coronary stenoses using virtual non-calcium (VNCa) images in coronary CT angiography (CCTA) with photon-counting detector (PCD) CT compared with quantitative coronary angiography (QCA). Materials and methods This retrospective, institutional-review board approved study included consecutive patients with calcified coronary artery plaques undergoing CCTA with PCD-CT and invasive coronary angiography between July and December 2022. Virtual monoenergetic images (VMI) and VNCa images were reconstructed. Diameter stenoses were quantified on VMI and VNCa images by two readers. 3D-QCA served as the standard of reference. Measurements were compared using Bland-Altman analyses, Wilcoxon tests, and intraclass correlation coefficients (ICC). Results Thirty patients [mean age, 64 years ± 8 (standard deviation); 26 men] with 81 coronary stenoses from calcified plaques were included. Ten of the 81 stenoses (12%) had to be excluded because of erroneous plaque subtraction on VNCa images. Median diameter stenosis determined on 3D-QCA was 22% (interquartile range, 11%-35%; total range, 4%-88%). As compared with 3D-QCA, VMI overestimated diameter stenoses (mean differences -10%, p < .001, ICC: .87 and -7%, p < .001, ICC: .84 for reader 1 and 2, respectively), whereas VNCa images showed similar diameter stenoses (mean differences 0%, p = .68, ICC: .94 and 1%, p = .07, ICC: .93 for reader 1 and 2, respectively). Conclusion First experience in mainly minimal to moderate stenoses suggests that virtual calcium removal in CCTA with PCD-CT, when feasible, has the potential to improve the quantification of calcified stenoses.
Collapse
Affiliation(s)
- Victor Mergen
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | - Rengarajan Rajagopal
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- Department of Diagnostic and Interventional Radiology, All India Institute of Medical Sciences, Jodhpur, India
| | - Eduardo Bättig
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- Department of Radiology, La Fe University and Polytechnic Hospital, Valencia, Spain
| | - Robert Manka
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- Department of Cardiology, University Heart Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Alessandro Candreva
- Department of Cardiology, University Heart Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Eberhard
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- Institute of Radiology, Spitäler fmi AG, Spital Interlaken, Unterseen, Switzerland
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
14
|
Rajiah PS, Alkadhi H, Van Mieghem NM, Budde RPJ. Utility of Photon Counting CT in Transcatheter Structural Heart Disease Interventions. Semin Roentgenol 2024; 59:32-43. [PMID: 38388095 DOI: 10.1053/j.ro.2023.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 11/19/2023] [Accepted: 11/20/2023] [Indexed: 02/24/2024]
Affiliation(s)
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Nicolas M Van Mieghem
- Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands
| |
Collapse
|
15
|
Flohr T, Schmidt B, Ulzheimer S, Alkadhi H. Cardiac imaging with photon counting CT. Br J Radiol 2023; 96:20230407. [PMID: 37750856 PMCID: PMC10646663 DOI: 10.1259/bjr.20230407] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 08/17/2023] [Accepted: 08/24/2023] [Indexed: 09/27/2023] Open
Abstract
CT of the heart, in particular ECG-controlled coronary CT angiography (cCTA), has become clinical routine due to rapid technical progress with ever new generations of CT equipment. Recently, CT scanners with photon-counting detectors (PCD) have been introduced which have the potential to address some of the remaining challenges for cardiac CT, such as limited spatial resolution and lack of high-quality spectral data. In this review article, we briefly discuss the technical principles of photon-counting detector CT, and we give an overview on how the improved spatial resolution of photon-counting detector CT and the routine availability of spectral data can benefit cardiac applications. We focus on coronary artery calcium scoring, cCTA, and on the evaluation of the myocardium.
Collapse
Affiliation(s)
- Thomas Flohr
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Bernhard Schmidt
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Stefan Ulzheimer
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
16
|
Risch F, Bette S, Sinzinger A, Rippel K, Scheurig-Muenkler C, Kroencke T, Decker JA. Multiphase photon counting detector CT data sets - Which combination of contrast phase and virtual non-contrast algorithm is best suited to replace true non-contrast series in the assessment of active bleeding? Eur J Radiol 2023; 168:111125. [PMID: 37804649 DOI: 10.1016/j.ejrad.2023.111125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 09/07/2023] [Accepted: 09/28/2023] [Indexed: 10/09/2023]
Abstract
PURPOSE Aim of this study was to determine which virtual non-contrast (VNC) reconstruction algorithm, applied to which contrast phase of computed tomography angiography, best matches true non-contrast (TNC) images in the assessment of active bleeding. METHOD Patients who underwent a triphasic scan (pre-contrast, arterial, portal venous contrast) on a photon-counting detector CT (PCD-CT) (120 kV, image quality level 68) with suspected active (tumor, postoperative, spontaneous or other) bleeding were retrospectively included in this study. Conventional (VNCConv) and a calcium-preserving VNC algorithm (VNCPC) were derived from both arterial (art) and portal venous (pv) contrast scans, and analyzed quantitatively and qualitatively by two independent and blinded raters. RESULTS 40 patients (22 female, mean age 76 years) were included. Measurements of CT values showed significant albeit small differences between TNC and VNC for most analyzed tissue regions without clear superiority of a VNC algorithm or contrast phase (e.g. ΔHU fat TNC to VNCPCpv 3.1 HU). However, qualitative analysis showed a preference to VNCPCpv in terms of image quality (on a 5-point Likert scale VNCConvart = 3.5 ± 0.8, VNCPCart = 3.7 ± 0.7, VNCConvpv = 3.7 ± 0.7, VNCPCpv = 3.8 ± 0.7) and residual calcium contrast (VNCConvart = 3.0 ± 0.8, VNCPCart = 3.5 ± 0.7, VNCConvpv = 3.6 ± 0.7, VNCPCpv = 3.9 ± 0.6). CONCLUSIONS When multiple post-contrast phases are available, VNCPC series based on portal venous phase are the most suitable replacement for an additional pre-contrast scan, with the prospect of a significant reduction in patient radiation dose.
Collapse
Affiliation(s)
- Franka Risch
- University Hospital Augsburg, Department of Diagnostic and Interventional Radiology, Stenglinstr. 2, Augsburg, Germany
| | - Stefanie Bette
- University Hospital Augsburg, Department of Diagnostic and Interventional Radiology, Stenglinstr. 2, Augsburg, Germany
| | - Andrea Sinzinger
- University Hospital Augsburg, Department of Diagnostic and Interventional Radiology, Stenglinstr. 2, Augsburg, Germany
| | - Katharina Rippel
- University Hospital Augsburg, Department of Diagnostic and Interventional Radiology, Stenglinstr. 2, Augsburg, Germany
| | - Christian Scheurig-Muenkler
- University Hospital Augsburg, Department of Diagnostic and Interventional Radiology, Stenglinstr. 2, Augsburg, Germany
| | - Thomas Kroencke
- University Hospital Augsburg, Department of Diagnostic and Interventional Radiology, Stenglinstr. 2, Augsburg, Germany; Centre for Advanced Analytics and Predictive Sciences, Augsburg University, Universitätsstr. 2, 86159 Augsburg, Germany.
| | - Josua A Decker
- University Hospital Augsburg, Department of Diagnostic and Interventional Radiology, Stenglinstr. 2, Augsburg, Germany
| |
Collapse
|
17
|
Turrion Gomollon AM, Mergen V, Sartoretti T, Polacin M, Nakhostin D, Puippe G, Alkadhi H, Euler A. Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair: Triphasic CT With True Noncontrast Versus Biphasic CT With Virtual Noniodine Imaging. Invest Radiol 2023; 58:816-821. [PMID: 37358359 PMCID: PMC10581441 DOI: 10.1097/rli.0000000000000993] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 04/25/2023] [Indexed: 06/27/2023]
Abstract
OBJECTIVES The aim of this study was to compare image quality and endoleak detection after endovascular abdominal aortic aneurysm repair between a triphasic computed tomography (CT) with true noncontrast (TNC) and a biphasic CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT). MATERIALS AND METHODS Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were retrospectively included. Endoleak detection was evaluated by 2 blinded radiologists on 2 different readout sets (triphasic CT with TNC-arterial-venous vs biphasic CT with VNI-arterial-venous). Virtual noniodine images were reconstructed from the venous phase. The radiologic report with additional confirmation by an expert reader served as reference standard for endoleak presence. Sensitivity, specificity, and interreader agreement (Krippendorf α) were calculated. Image noise was assessed subjectively in patients using a 5-point scale and objectively calculating the noise power spectrum in a phantom. RESULTS One hundred ten patients (7 women; age, 76 ± 8 years) with 41 endoleaks were included. Endoleak detection was comparable between both readout sets with a sensitivity and specificity of 0.95/0.84 (TNC) versus 0.95/0.86 (VNI) for reader 1 and 0.88/0.98 (TNC) versus 0.88/0.94 (VNI) for reader 2. Interreader agreement for endoleak detection was substantial (TNC: 0.716, VNI: 0.756). Subjective image noise was comparable between TNC and VNI (4; IQR [4, 5] vs 4; IQR [4, 5], P = 0.44). In the phantom, noise power spectrum peak spatial frequency was similar between TNC and VNI (both f peak = 0.16 mm -1 ). Objective image noise was higher in TNC (12.7 HU) as compared with VNI (11.5 HU). CONCLUSIONS Endoleak detection and image quality were comparable using VNI images in biphasic CT as compared with TNC images in triphasic CT offering the possibility to reduce scan phases and radiation exposure.
Collapse
|
18
|
Chauvie S, Mazzoni LN, O’Doherty J. A Review on the Use of Imaging Biomarkers in Oncology Clinical Trials: Quality Assurance Strategies for Technical Validation. Tomography 2023; 9:1876-1902. [PMID: 37888741 PMCID: PMC10610870 DOI: 10.3390/tomography9050149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/10/2023] [Accepted: 10/13/2023] [Indexed: 10/28/2023] Open
Abstract
Imaging biomarkers (IBs) have been proposed in medical literature that exploit images in a quantitative way, going beyond the visual assessment by an imaging physician. These IBs can be used in the diagnosis, prognosis, and response assessment of several pathologies and are very often used for patient management pathways. In this respect, IBs to be used in clinical practice and clinical trials have a requirement to be precise, accurate, and reproducible. Due to limitations in imaging technology, an error can be associated with their value when considering the entire imaging chain, from data acquisition to data reconstruction and subsequent analysis. From this point of view, the use of IBs in clinical trials requires a broadening of the concept of quality assurance and this can be a challenge for the responsible medical physics experts (MPEs). Within this manuscript, we describe the concept of an IB, examine some examples of IBs currently employed in clinical practice/clinical trials and analyze the procedure that should be carried out to achieve better accuracy and reproducibility in their use. We anticipate that this narrative review, written by the components of the EFOMP working group on "the role of the MPEs in clinical trials"-imaging sub-group, can represent a valid reference material for MPEs approaching the subject.
Collapse
Affiliation(s)
- Stephane Chauvie
- Medical Physics Division, Santa Croce e Carle Hospital, 12100 Cuneo, Italy;
| | | | - Jim O’Doherty
- Siemens Medical Solutions, Malvern, PA 19355, USA;
- Department of Radiology & Radiological Sciences, Medical University of South Carolina, Charleston, SC 20455, USA
- Radiography & Diagnostic Imaging, University College Dublin, D04 C7X2 Dublin, Ireland
| |
Collapse
|
19
|
Wu Y, Ye Z, Chen J, Deng L, Song B. Photon Counting CT: Technical Principles, Clinical Applications, and Future Prospects. Acad Radiol 2023; 30:2362-2382. [PMID: 37369618 DOI: 10.1016/j.acra.2023.05.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 05/27/2023] [Accepted: 05/28/2023] [Indexed: 06/29/2023]
Abstract
Photon-counting computed tomography (PCCT) is a new technique that utilizes photon-counting detectors to convert individual X-ray photons directly into an electrical signal, which can achieve higher spatial resolution, improved iodine signal, radiation dose reduction, artifact reduction, and multienergy imaging. This review introduces the technical principles of PCCT, and summarizes its first-in-human experience and current applications in clinical settings, and discusses the future prospects of PCCT.
Collapse
Affiliation(s)
- Yingyi Wu
- Department of Radiology, West China Hospital, Sichuan University, No. 37 Guoxue Alley, Chengdu 610041, China (Y.Y.W., Z.Y., J.C., L.P.D., B.S.)
| | - Zheng Ye
- Department of Radiology, West China Hospital, Sichuan University, No. 37 Guoxue Alley, Chengdu 610041, China (Y.Y.W., Z.Y., J.C., L.P.D., B.S.)
| | - Jie Chen
- Department of Radiology, West China Hospital, Sichuan University, No. 37 Guoxue Alley, Chengdu 610041, China (Y.Y.W., Z.Y., J.C., L.P.D., B.S.)
| | - Liping Deng
- Department of Radiology, West China Hospital, Sichuan University, No. 37 Guoxue Alley, Chengdu 610041, China (Y.Y.W., Z.Y., J.C., L.P.D., B.S.)
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, No. 37 Guoxue Alley, Chengdu 610041, China (Y.Y.W., Z.Y., J.C., L.P.D., B.S.); Department of Radiology, Sanya People' s Hospital, Sanya, Hainan, China (B.S.).
| |
Collapse
|
20
|
Douek PC, Boccalini S, Oei EHG, Cormode DP, Pourmorteza A, Boussel L, Si-Mohamed SA, Budde RPJ. Clinical Applications of Photon-counting CT: A Review of Pioneer Studies and a Glimpse into the Future. Radiology 2023; 309:e222432. [PMID: 37787672 PMCID: PMC10623209 DOI: 10.1148/radiol.222432] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 03/24/2023] [Accepted: 04/11/2023] [Indexed: 10/04/2023]
Abstract
CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.
Collapse
Affiliation(s)
| | | | - Edwin H. G. Oei
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - David P. Cormode
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Amir Pourmorteza
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Loic Boussel
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Salim A. Si-Mohamed
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Ricardo P. J. Budde
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| |
Collapse
|
21
|
Fink N, Zsarnoczay E, Schoepf UJ, O'Doherty J, Halfmann MC, Allmendinger T, Hagenauer J, Griffith JP, Vecsey-Nagy M, Pinos D, Ebersberger U, Ricke J, Varga-Szemes A, Emrich T. Impact of Cardiac Motion on coronary artery calcium scoring using a virtual non-iodine algorithm on photon-counting detector CT: a dynamic phantom study. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2023; 39:2083-2092. [PMID: 37452987 DOI: 10.1007/s10554-023-02912-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 06/27/2023] [Indexed: 07/18/2023]
Abstract
This study assessed the impact of cardiac motion and in-vessel attenuation on coronary artery calcium (CAC) scoring using virtual non-iodine (VNI) against virtual non-contrast (VNC) reconstructions on photon-counting detector CT. Two artificial vessels containing calcifications and different in-vessel attenuations (500, 800HU) were scanned without (static) and with cardiac motion (60, 80, 100 beats per minute [bpm]). Images were post-processed using a VNC and VNI algorithm at 70 keV and quantum iterative reconstruction (QIR) strength 2. Calcium mass, Agatston scores, cardiac motion susceptibility (CMS)-indices were compared to physical mass, static scores as well as between reconstructions, heart rates and in-vessel attenuations. VNI scores decreased with rising heart rate (p < 0.01) and showed less underestimation than VNC scores (p < 0.001). Only VNI scores were similar to the physical mass at static measurements, and to static scores at 60 bpm. Agatston scores using VNI were similar to static scores at 60 and 80 bpm. Standard deviation of CMS-indices was lower for VNI-based than for VNC-based CAC scoring. VNI scores were higher at 500 than 800HU (p < 0.001) and higher than VNC scores (p < 0.001) with VNI scores at 500 HU showing the lowest deviation from the physical reference. VNI-based CAC quantification is influenced by cardiac motion and in-vessel attenuation, but least when measuring Agatston scores, where it outperforms VNC-based CAC scoring.
Collapse
Affiliation(s)
- Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
- Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
- Medical Imaging Center, Semmelweis University, Korányi Sándor utca 2, Budapest, 1083, Hungary
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA.
| | - Jim O'Doherty
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
- Siemens Medical Solutions, Malvern, PA, 19355, USA
| | - Moritz C Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center of Johannes Gutenberg- University, Langenbeckstr. 1, Mainz, 55131, Germany
| | | | - Junia Hagenauer
- Siemens Healthcare GmbH, Siemensstr. 1, Forchheim, 91301, Germany
- Faculty of Medicine, Friedrich Alexander University of Erlangen-Nuremberg, Krankenhausstr. 12, Erlangen, 91054, Germany
| | - Joseph P Griffith
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
| | - Milán Vecsey-Nagy
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Varosmajor utca 68, Budapest, 1122, Hungary
| | - Daniel Pinos
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
| | - Ullrich Ebersberger
- Department of Cardiology, Munich University Clinic, Ludwig-Maximilians-University, Munich, 80636, Germany
| | - Jens Ricke
- Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC, 29425, USA
- Department of Diagnostic and Interventional Radiology, University Medical Center of Johannes Gutenberg- University, Langenbeckstr. 1, Mainz, 55131, Germany
- German Centre for Cardiovascular Research, Mainz, 55131, Germany
| |
Collapse
|
22
|
Liu LP, Shapira N, Sahbaee P, Gang GJ, Knollman FD, Chen MY, Litt HI, Noël PB. Consistency of spectral results in cardiac dual-source photon-counting CT. Sci Rep 2023; 13:14895. [PMID: 37689744 PMCID: PMC10492823 DOI: 10.1038/s41598-023-41969-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 09/04/2023] [Indexed: 09/11/2023] Open
Abstract
We evaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT). A cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned at five different heart rates (0, 60-100 bpm) with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were calculated for virtual monoenergetic images (VMI) at 50, 70, and 150 keV and iodine density maps at both diastole and systole. FWHM averaged differences of - 0.20, - 0.28, and - 0.15 mm relative to static FWHM at VMI 150 keV across acquisition parameters for high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, and retrospectively ECG-gated spiral scans, respectively. Additionally, there was no effect of heart rate and acquisition mode on FWHM at diastole (p-values < 0.001). DSC demonstrated similarity among parameters with standard deviations of 0.08, 0.09, 0.11, and 0.08 for VMI 50, 70, and 150 keV, and iodine density maps, respectively, with insignificant differences at diastole (p-values < 0.01). Similarly, eccentricity illustrated small differences across heart rate and acquisition mode for each spectral result. Consistency of spectral results at different heart rates and acquisition modes for different cardiac phase demonstrates the added benefit of spectral results from PCCT to dual-source CT to further increase confidence in quantification and advance cardiovascular diagnostics.
Collapse
Affiliation(s)
- Leening P Liu
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA.
| | - Nadav Shapira
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Grace J Gang
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Marcus Y Chen
- National Heart, Lung, and Blood Institute, Bethesda, MD, USA
| | - Harold I Litt
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Peter B Noël
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
| |
Collapse
|
23
|
Vecsey-Nagy M, Varga-Szemes A, Emrich T, Zsarnoczay E, Nagy N, Fink N, Schmidt B, Nowak T, Kiss M, Vattay B, Boussoussou M, Kolossváry M, Kubovje A, Merkely B, Maurovich-Horvat P, Szilveszter B. Calcium scoring on coronary computed angiography tomography with photon-counting detector technology: Predictors of performance. J Cardiovasc Comput Tomogr 2023; 17:328-335. [PMID: 37635032 DOI: 10.1016/j.jcct.2023.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/10/2023] [Accepted: 08/05/2023] [Indexed: 08/29/2023]
Abstract
INTRODUCTION Obtaining accurate coronary artery calcium (CAC) score measurements from CCTA datasets with virtual non-iodine (VNI) algorithms would reduce acquisition time and radiation dose. We aimed to assess the agreement of VNI-derived and conventional true non-contrast (TNC)-based CAC scores and to identify the predictors of accuracy. METHODS CCTA datasets were acquired with either 120 or 140 kVp. CAC scores and volumes were calculated from TNC and VNI images in 197 consecutive patients undergoing CCTA. CAC density score, mean volume/lesion, aortic Hounsfield units and standard deviations were then measured. Finally, percentage deviation (VNI - TNC/TNC∗100) of CTA-derived CAC scores from non-enhanced scans was calculated for each patient. Predictors (including anthropometric and acquisition parameters, as well as CAC characteristics) of the degree of discrepancy were evaluated using linear regression analysis. RESULTS While the agreement between TNC and VNI was substantial (mean bias, 6.6; limits of agreement, 178.5/145.3), a non-negligible proportion of patients (36/197, 18.3%) were falsely reclassified as CAC score = 0 on VNI. The use of higher tube voltage significantly decreased the percentage deviation relative to TNC-based values (β = -0.21 [95%CI: 0.38 to -0.03], p = 0.020) and a higher CAC density score also proved to be an independent predictor of a smaller difference (β = -0.22 [95%CI: 0.37 to -0.07], p = 0.006). CONCLUSION The performance of VNI-based calcium scoring may be improved by increased tube voltage protocols, while the accuracy may be compromised for calcified lesions of lower density. The implementation of VNI in clinical routine, however, needs to be preceded by a solution for detecting smaller lesions as well.
Collapse
Affiliation(s)
- M Vecsey-Nagy
- Heart and Vascular Center of Semmelweis University, Budapest, Hungary; Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA
| | - A Varga-Szemes
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA
| | - T Emrich
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA; Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - E Zsarnoczay
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA; Medical Imaging Center of Semmelweis University, Budapest, Hungary
| | - N Nagy
- Medical Imaging Center of Semmelweis University, Budapest, Hungary
| | - N Fink
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA; Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - B Schmidt
- Siemens Healthcare GmbH, Forchheim, Germany
| | - T Nowak
- Siemens Healthcare GmbH, Forchheim, Germany
| | - M Kiss
- Siemens Healthcare GmbH, Forchheim, Germany
| | - B Vattay
- Heart and Vascular Center of Semmelweis University, Budapest, Hungary
| | - M Boussoussou
- Heart and Vascular Center of Semmelweis University, Budapest, Hungary
| | - M Kolossváry
- Gottsegen National Cardiovascular Center, Budapest, Hungary; Physiological Controls Research Center, Budapest, Hungary
| | - A Kubovje
- Medical Imaging Center of Semmelweis University, Budapest, Hungary
| | - B Merkely
- Heart and Vascular Center of Semmelweis University, Budapest, Hungary
| | | | - B Szilveszter
- Heart and Vascular Center of Semmelweis University, Budapest, Hungary.
| |
Collapse
|
24
|
Meloni A, Cademartiri F, Positano V, Celi S, Berti S, Clemente A, La Grutta L, Saba L, Bossone E, Cavaliere C, Punzo B, Maffei E. Cardiovascular Applications of Photon-Counting CT Technology: A Revolutionary New Diagnostic Step. J Cardiovasc Dev Dis 2023; 10:363. [PMID: 37754792 PMCID: PMC10531582 DOI: 10.3390/jcdd10090363] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 08/16/2023] [Accepted: 08/18/2023] [Indexed: 09/28/2023] Open
Abstract
Photon-counting computed tomography (PCCT) is an emerging technology that can potentially transform clinical CT imaging. After a brief description of the PCCT technology, this review summarizes its main advantages over conventional CT: improved spatial resolution, improved signal and contrast behavior, reduced electronic noise and artifacts, decreased radiation dose, and multi-energy capability with improved material discrimination. Moreover, by providing an overview of the existing literature, this review highlights how the PCCT benefits have been harnessed to enhance and broaden the diagnostic capabilities of CT for cardiovascular applications, including the detection of coronary artery calcifications, evaluation of coronary plaque extent and composition, evaluation of coronary stents, and assessment of myocardial tissue characteristics and perfusion.
Collapse
Affiliation(s)
- Antonella Meloni
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
- Unità Operativa Complessa di Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy
| | - Filippo Cademartiri
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
| | - Vicenzo Positano
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
- Unità Operativa Complessa di Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy
| | - Simona Celi
- BioCardioLab, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Sergio Berti
- Diagnostic and Interventional Cardiology Department, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Alberto Clemente
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
| | - Ludovico La Grutta
- Department of Radiology, University Hospital “P. Giaccone”, 90127 Palermo, Italy;
| | - Luca Saba
- Department of Radiology, University Hospital of Cagliari, 09042 Monserrato, CA, Italy;
| | - Eduardo Bossone
- Department of Cardiology, Ospedale Cardarelli, 80131 Naples, Italy;
| | - Carlo Cavaliere
- Department of Radiology, Istituto di Ricerca e Cura a Carattere Scientifico SynLab-SDN, 80131 Naples, Italy; (C.C.); (B.P.)
| | - Bruna Punzo
- Department of Radiology, Istituto di Ricerca e Cura a Carattere Scientifico SynLab-SDN, 80131 Naples, Italy; (C.C.); (B.P.)
| | - Erica Maffei
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
| |
Collapse
|
25
|
Lell M, Kachelrieß M. Computed Tomography 2.0: New Detector Technology, AI, and Other Developments. Invest Radiol 2023; 58:587-601. [PMID: 37378467 PMCID: PMC10332658 DOI: 10.1097/rli.0000000000000995] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/04/2023] [Indexed: 06/29/2023]
Abstract
ABSTRACT Computed tomography (CT) dramatically improved the capabilities of diagnostic and interventional radiology. Starting in the early 1970s, this imaging modality is still evolving, although tremendous improvements in scan speed, volume coverage, spatial and soft tissue resolution, as well as dose reduction have been achieved. Tube current modulation, automated exposure control, anatomy-based tube voltage (kV) selection, advanced x-ray beam filtration, and iterative image reconstruction techniques improved image quality and decreased radiation exposure. Cardiac imaging triggered the demand for high temporal resolution, volume acquisition, and high pitch modes with electrocardiogram synchronization. Plaque imaging in cardiac CT as well as lung and bone imaging demand for high spatial resolution. Today, we see a transition of photon-counting detectors from experimental and research prototype setups into commercially available systems integrated in patient care. Moreover, with respect to CT technology and CT image formation, artificial intelligence is increasingly used in patient positioning, protocol adjustment, and image reconstruction, but also in image preprocessing or postprocessing. The aim of this article is to give an overview of the technical specifications of up-to-date available whole-body and dedicated CT systems, as well as hardware and software innovations for CT systems in the near future.
Collapse
|
26
|
Abstract
ABSTRACT Noninvasive vascular imaging with computed tomography (CT) has become the clinical mainstay for many indications and body regions. The recent introduction of photon-counting detector (PCD)-CT into clinical routine has further broadened the spectrum of vascular applications. Technical improvements of PCD-CT, such as the decreased noise levels, improved contrast-to-noise ratio, and full spectral multienergy data information from every acquisition, have the potential to further impact on clinical decision making and ultimately on outcome of vascular patients. Early experience with the new PCD-CT technology demonstrates these improvements in various aspects. This review summarizes the main advantages of PCD-CT for vascular imaging a discussion of the PureLumen and PureCalcium algorithms.
Collapse
Affiliation(s)
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
27
|
Yamaoka T, Watanabe S. Artificial intelligence in coronary artery calcium measurement: Barriers and solutions for implementation into daily practice. Eur J Radiol 2023; 164:110855. [PMID: 37167685 DOI: 10.1016/j.ejrad.2023.110855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/29/2023] [Accepted: 04/28/2023] [Indexed: 05/13/2023]
Abstract
Coronary artery calcification (CAC) measurement is a valuable predictor of cardiovascular risk. However, its measurement can be time-consuming and complex, thus driving the desire for artificial intelligence (AI)-based approaches. The aim of this review is to explore the current status of CAC volume measurement using AI-based systems for the automated prediction of cardiovascular events. We also make proposals for the implementation of these systems into clinical practice. Research to date on applying AI to CAC scoring has shown the potential for automation and risk stratification, and, overall, efficacy and a high level of agreement with categorisation by trained clinicians have been demonstrated. However, research in this field has not been uniform or directed. One contributing factor may be a lack of integration and communication between computer scientists and cardiologists. Clinicians, institutions, and organisations should work together towards applying this technology to improve processes, preserve healthcare resources, and improve patient outcomes.
Collapse
Affiliation(s)
- Toshihide Yamaoka
- Department of Diagnostic Imaging and Interventional Radiology, Kyoto Katsura Hospital, Japan.
| | - Sachika Watanabe
- Department of Diagnostic Imaging and Interventional Radiology, Kyoto Katsura Hospital, Japan
| |
Collapse
|
28
|
McCollough CH, Rajendran K, Leng S. Standardization and Quantitative Imaging With Photon-Counting Detector CT. Invest Radiol 2023; 58:451-458. [PMID: 36728452 PMCID: PMC10272018 DOI: 10.1097/rli.0000000000000948] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
ABSTRACT Computed tomography (CT) images display anatomic structures across 3 dimensions and are highly quantitative; they are the reference standard for 3-dimensional geometric measurements and are used for 3-dimensional printing of anatomic models and custom implants, as well as for radiation therapy treatment planning. The pixel intensity in CT images represents the linear x-ray attenuation coefficient of the imaged materials after linearly scaling the coefficients into a quantity known as CT numbers that is conveyed in Hounsfield units. When measured with the same scanner model, acquisition, and reconstruction parameters, the mean CT number of a material is highly reproducible, and quantitative applications of CT scanning that rely on the measured CT number, such as for assessing bone mineral density or coronary artery calcification, are well established. However, the strong dependence of CT numbers on x-ray beam spectra limits quantitative applications and standardization from achieving robust widespread success. This article reviews several quantitative applications of CT and the challenges they face, and describes the benefits brought by photon-counting detector (PCD) CT technology. The discussed benefits of PCD-CT include that it is inherently multienergy, expands material decomposition capabilities, and improves spatial resolution and geometric quantification. Further, the utility of virtual monoenergetic images to standardize CT numbers is discussed, as virtual monoenergetic images can be the default image type in PCD-CT due to the full-time spectral nature of the technology.
Collapse
Affiliation(s)
- Cynthia H. McCollough
- Department of Radiology, Mayo Clinic, 200 First St SW Rochester, MN, United States 55905
| | - Kishore Rajendran
- Department of Radiology, Mayo Clinic, 200 First St SW Rochester, MN, United States 55905
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, 200 First St SW Rochester, MN, United States 55905
| |
Collapse
|
29
|
Jost G, McDermott M, Gutjahr R, Nowak T, Schmidt B, Pietsch H. New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT. Invest Radiol 2023; 58:515-522. [PMID: 37068840 PMCID: PMC10259215 DOI: 10.1097/rli.0000000000000978] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 03/01/2023] [Indexed: 04/19/2023]
Abstract
ABSTRACT The recent technological developments in photon-counting detector computed tomography (PCD-CT) and the introduction of the first commercially available clinical PCD-CT unit open up new exciting opportunities for contrast media research. With PCD-CT, the efficacy of available iodine-based contrast media improves, allowing for a reduction of iodine dosage or, on the other hand, an improvement of image quality in low contrast indications. Virtual monoenergetic image reconstructions are routinely available and enable the virtual monoenergetic image energy to be adapted to the diagnostic task.A key property of PCD-CT is the ability of spectral separation in combination with improved material decomposition. Thus, the discrimination of contrast media from intrinsic or pathological tissues and the discrimination of 2 or more contrasting elements that characterize different tissues are attractive fields for contrast media research. For these approaches, K-edge imaging in combination with high atomic number elements such as the lanthanides, tungsten, tantalum, or bismuth plays a central role.The purpose of this article is to present an overview of innovative contrast media concepts that use high atomic number elements. The emphasis is on improving contrast enhancement for cardiovascular plaque imaging, stent visualization, and exploring new approaches using 2 contrasting elements. Along with the published research, new experimental findings with a contrast medium that incorporates tungsten are included.Both the literature review and the new experimental data demonstrate the great potential and feasibility for new contrast media to significantly increase diagnostic performance and to enable new clinical fields and indications in combination with PCD-CT.
Collapse
Affiliation(s)
- Gregor Jost
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
| | - Michael McDermott
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Ralf Gutjahr
- Computed Tomography, Siemens Healthineers, Forchheim, Germany
| | - Tristan Nowak
- Computed Tomography, Siemens Healthineers, Forchheim, Germany
| | | | - Hubertus Pietsch
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
| |
Collapse
|
30
|
Flohr T, Schmidt B. Technical Basics and Clinical Benefits of Photon-Counting CT. Invest Radiol 2023; 58:441-450. [PMID: 37185302 PMCID: PMC10259209 DOI: 10.1097/rli.0000000000000980] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Accepted: 03/05/2023] [Indexed: 05/17/2023]
Abstract
ABSTRACT Novel photon-counting detector CT (PCD-CT) has the potential to address the limitations of previous CT systems, such as insufficient spatial resolution, limited accuracy in detecting small low-contrast structures, or missing routine availability of spectral information. In this review article, we explain the basic principles and potential clinical benefits of PCD-CT, with a focus on recent literature that has grown rapidly since the commercial introduction of a clinically approved PCD-CT.
Collapse
|
31
|
Zsarnóczay E, Varga-Szemes A, Emrich T, Szilveszter B, van der Werf NR, Mastrodicasa D, Maurovich-Horvat P, Willemink MJ. Characterizing the Heart and the Myocardium With Photon-Counting CT. Invest Radiol 2023; 58:505-514. [PMID: 36822653 DOI: 10.1097/rli.0000000000000956] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
ABSTRACT Noninvasive cardiac imaging has rapidly evolved during the last decade owing to improvements in computed tomography (CT)-based technologies, among which we highlight the recent introduction of the first clinical photon-counting detector CT (PCD-CT) system. Multiple advantages of PCD-CT have been demonstrated, including increased spatial resolution, decreased electronic noise, and reduced radiation exposure, which may further improve diagnostics and may potentially impact existing management pathways. The benefits that can be obtained from the initial experiences with PCD-CT are promising. The implementation of this technology in cardiovascular imaging allows for the quantification of coronary calcium, myocardial extracellular volume, myocardial radiomics features, epicardial and pericoronary adipose tissue, and the qualitative assessment of coronary plaques and stents. This review aims to discuss these major applications of PCD-CT with a focus on cardiac and myocardial characterization.
Collapse
Affiliation(s)
| | - Akos Varga-Szemes
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston
| | | | | | | | | | | | | |
Collapse
|
32
|
Yang Y, Fink N, Emrich T, Graafen D, Richter R, Bockius S, Wolf EV, Laux G, Kavermann L, Müller L, Hell M, Halfmann MC. Optimization of Kernel Type and Sharpness Level Improves Objective and Subjective Image Quality for High-Pitch Photon Counting Coronary CT Angiography. Diagnostics (Basel) 2023; 13:diagnostics13111937. [PMID: 37296789 DOI: 10.3390/diagnostics13111937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 05/25/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023] Open
Abstract
(1) Background: Photon-counting detector (PCD) CT offers a wide variety of kernels and sharpness levels for image reconstruction. The aim of this retrospective study was to determine optimal settings for coronary CT angiography (CCTA). (2) Methods: Thirty patients (eight female, mean age 63 ± 13 years) underwent PCD-CCTA in a high-pitch mode. Images were reconstructed using three different kernels and four sharpness levels (Br36/40/44/48, Bv36/40/44/48, and Qr36/40/44/48). To analyze objective image quality, the attenuation, image noise, contrast-to-noise ratio (CNR), and vessel sharpness were quantified in proximal and distal coronaries. For subjective image quality, two blinded readers assessed image noise, visually sharp reproduction of coronaries, and the overall image quality using a five-point Likert scale. (3) Results: Attenuation, image noise, CNR, and vessel sharpness significantly differed across kernels (all p < 0.001), with the Br-kernel reaching the highest attenuation. With increasing kernel sharpness, image noise and vessel sharpness increased, whereas CNR continuously decreased. Reconstruction with Br-kernel generally had the highest CNR (Br > Bv > Qr), except Bv-kernel had a superior CNR at sharpness level 40. Bv-kernel had significantly higher vessel sharpness than Br- and Qr-kernel (p < 0.001). Subjective image quality was rated best for kernels Bv40 and Bv36, followed by Br36 and Qr36. (4) Conclusion: Reconstructions with kernel Bv40 are beneficial to achieve optimal image quality in spectral high-pitch CCTA using PCD-CT.
Collapse
Affiliation(s)
- Yang Yang
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
- Department of Radiology, University Hospital, LMU Munich, 81377 Munich, Germany
| | - Tilman Emrich
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
| | - Dirk Graafen
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Rosa Richter
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Stefanie Bockius
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Elias V Wolf
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Gerald Laux
- Department of Cardiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Larissa Kavermann
- Department of Cardiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Lukas Müller
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Michaela Hell
- Department of Cardiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| | - Moritz C Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany
| |
Collapse
|
33
|
Williams MC, Newby DE. Photon-counting CT: A Step Change Leading to a Revolution in Coronary Imaging. Radiology 2023; 307:e231234. [PMID: 37338352 PMCID: PMC10315513 DOI: 10.1148/radiol.231234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/02/2023] [Accepted: 06/02/2023] [Indexed: 06/21/2023]
Affiliation(s)
- Michelle C. Williams
- From the British Heart Foundation Centre for Cardiovascular Science,
University of Edinburgh, Chancellor's Building, 49 Little France
Crescent, Edinburgh EH16 SUF, UK
| | - David E. Newby
- From the British Heart Foundation Centre for Cardiovascular Science,
University of Edinburgh, Chancellor's Building, 49 Little France
Crescent, Edinburgh EH16 SUF, UK
| |
Collapse
|
34
|
Mergen V, Ghouse S, Sartoretti T, Manka R, Euler A, Kasel AM, Alkadhi H, Eberhard M. Cardiac Virtual Noncontrast Images for Calcium Quantification with Photon-counting Detector CT. Radiol Cardiothorac Imaging 2023; 5:e220307. [PMID: 37404795 PMCID: PMC10316300 DOI: 10.1148/ryct.220307] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 03/29/2023] [Accepted: 05/08/2023] [Indexed: 07/06/2023]
Abstract
Purpose To assess the accuracy of aortic valve calcium (AVC), mitral annular calcium (MAC), and coronary artery calcium (CAC) quantification and risk stratification using virtual noncontrast (VNC) images from late enhancement photon-counting detector CT as compared with true noncontrast images. Materials and Methods This retrospective, institutional review board-approved study evaluated patients undergoing photon-counting detector CT between January and September 2022. VNC images were reconstructed from late enhancement cardiac scans at 60, 70, 80, and 90 keV using quantum iterative reconstruction (QIR) strengths of 2-4. AVC, MAC, and CAC were quantified on VNC images and compared with quantification of AVC, MAC, and CAC on true noncontrast images using Bland-Altman analyses, regression models, intraclass correlation coefficients (ICC), and Wilcoxon tests. Agreement between severe aortic stenosis likelihood categories and CAC risk categories determined from VNC and true noncontrast images was assessed by weighted κ analysis. Results Ninety patients were included (mean age, 80 years ± 8 [SD]; 49 male patients). Scores were similar on true noncontrast images and VNC images at 80 keV for AVC and MAC, regardless of QIR strengths, and VNC images at 70 keV with QIR 4 for CAC (all P > .05). The best results were achieved using VNC images at 80 keV with QIR 4 for AVC (mean difference, 3; ICC = 0.992; r = 0.98) and MAC (mean difference, 6; ICC = 0.998; r = 0.99), and VNC images at 70 keV with QIR 4 for CAC (mean difference, 28; ICC = 0.996; r = 0.99). Agreement between calcification categories was excellent on VNC images at 80 keV for AVC (κ = 0.974) and on VNC images at 70 keV for CAC (κ = 0.967). Conclusion VNC images from cardiac photon-counting detector CT enables patient risk stratification and accurate quantification of AVC, MAC, and CAC.Keywords: Coronary Arteries, Aortic Valve, Mitral Valve, Aortic Stenosis, Calcifications, Photon-counting Detector CT Supplemental material is available for this article © RSNA, 2023.
Collapse
|
35
|
Fink N, Zsarnoczay E, Schoepf UJ, O'Doherty J, Griffith JP, Pinos D, Tesche C, Ricke J, Willemink MJ, Varga-Szemes A, Emrich T. Radiation Dose Reduction for Coronary Artery Calcium Scoring Using a Virtual Noniodine Algorithm on Photon-Counting Detector Computed-Tomography Phantom Data. Diagnostics (Basel) 2023; 13:diagnostics13091540. [PMID: 37174932 PMCID: PMC10177425 DOI: 10.3390/diagnostics13091540] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/14/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023] Open
Abstract
Background: On the basis of the hypothesis that virtual noniodine (VNI)-based coronary artery calcium scoring (CACS) is feasible at reduced radiation doses, this study assesses the impact of radiation dose reduction on the accuracy of this VNI algorithm on a photon-counting detector (PCD)-CT. Methods: In a systematic in vitro setting, a phantom for CACS simulating three chest sizes was scanned on a clinical PCD-CT. The standard radiation dose was chosen at volumetric CT dose indices (CTDIVol) of 1.5, 3.3, 7.0 mGy for small, medium-sized, and large phantoms, and was gradually reduced by adjusting the tube current resulting in 100, 75, 50, and 25%, respectively. VNI images were reconstructed at 55 keV, quantum iterative reconstruction (QIR)1, and at 60 keV/QIR4, and evaluated regarding image quality (image noise (IN), contrast-to-noise ratio (CNR)), and CACS. All VNI results were compared to true noncontrast (TNC)-based CACS at 70 keV and standard radiation dose (reference). Results: INTNC was significantly higher than INVNI, and INVNI at 55 keV/QIR1 higher than at 60 keV/QIR4 (100% dose: 16.7 ± 1.9 vs. 12.8 ± 1.7 vs. 7.7 ± 0.9; p < 0.001 for every radiation dose). CNRTNC was higher than CNRVNI, but it was better to use 60 keV/QIR4 (p < 0.001). CACSVNI showed strong correlation and agreement at every radiation dose (p < 0.001, r > 0.9, intraclass correlation coefficient > 0.9). The coefficients of the variation in root-mean squared error were less than 10% and thus clinically nonrelevant for the CACSVNI of every radiation dose. Conclusion: This phantom study suggests that CACSVNI is feasible on PCD-CT, even at reduced radiation dose while maintaining image quality and CACS accuracy.
Collapse
Affiliation(s)
- Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
- Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
- Medical Imaging Center, Semmelweis University, Korányi Sándor utca 2, 1083 Budapest, Hungary
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
| | - Jim O'Doherty
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
- Siemens Medical Solutions, 40 Liberty Boulevard, Malvern, PA 19355, USA
| | - Joseph P Griffith
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
| | - Daniel Pinos
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
| | - Christian Tesche
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
- Department of Cardiology, Munich University Clinic, Ludwig-Maximilians-University, Marchioninistr. 15, 81377 Munich, Germany
| | - Jens Ricke
- Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany
| | - Martin J Willemink
- Department of Radiology, Stanford University School of Medicine, 291 Campus Drive, Stanford, CA 94305, USA
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
- Department of Diagnostic and Interventional Radiology, University Medical Center of Johannes-Gutenberg-University, Langenbeckstr. 1, 55131 Mainz, Germany
- German Centre for Cardiovascular Research, Partner Site Rhine-Main, 55131 Mainz, Germany
| |
Collapse
|
36
|
van der Bie J, van Straten M, Booij R, Bos D, Dijkshoorn ML, Hirsch A, Sharma SP, Oei EHG, Budde RPJ. Photon-counting CT: Review of initial clinical results. Eur J Radiol 2023; 163:110829. [PMID: 37080060 DOI: 10.1016/j.ejrad.2023.110829] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 04/05/2023] [Indexed: 04/22/2023]
Abstract
Photon-counting computed tomography (PCCT) is a new technology that enables higher spatial resolution compared to conventional CT techniques, energy resolved imaging and spectral post-processing. This leads to improved contrast-to-noise ratio, artifact and potential dose reduction as well as elimination of electronic noise. Since the introduction of clinical PCCT in 2021, a shift has been observed from solely pre-clinical studies to clinical research (i.e. use of PCCT imaging in humans). This review article is focused on the initial clinical results of PCCT by explaining the current PCCT systems, the applications themselves and, the challenges of PCCT.
Collapse
Affiliation(s)
- Judith van der Bie
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Marcel van Straten
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Ronald Booij
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Daniel Bos
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands; Department of Epidemiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Marcel L Dijkshoorn
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Alexander Hirsch
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands; Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Simran P Sharma
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands; Department of Cardiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Edwin H G Oei
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
| |
Collapse
|
37
|
Assessment of epicardial adipose tissue on virtual non-contrast images derived from photon-counting detector coronary CTA datasets. Eur Radiol 2023; 33:2450-2460. [PMID: 36462042 PMCID: PMC10017616 DOI: 10.1007/s00330-022-09257-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Revised: 10/04/2022] [Accepted: 10/19/2022] [Indexed: 12/05/2022]
Abstract
OBJECTIVES To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from coronary CTA (CCTA) datasets of a photon-counting detector (PCD) CT-system to replace true non-contrast (TNC) series. METHODS Consecutive patients (n = 42) with clinically indicated CCTA and coronary TNC were included. Two VNC series were reconstructed, using a conventional (VNCConv) and a novel calcium-preserving (VNCPC) algorithm. EAT was segmented on TNC, VNCConv, VNCPC, and CCTA (CTA-30) series using thresholds of -190 to -30 HU and an additional segmentation on the CCTA series with an upper threshold of 0 HU (CTA0). EAT volumes and their histograms were assessed for each series. Linear regression was used to correlate EAT volumes and the Euclidian distance for histograms. The paired t-test and the Wilcoxon signed-rank test were used to assess differences for parametric and non-parametric data. RESULTS EAT volumes from VNC and CCTA series showed significant differences compared to TNC (all p < .05), but excellent correlation (all R2 > 0.9). Measurements on the novel VNCPC series showed the best correlation (R2 = 0.99) and only minor absolute differences compared to TNC values. Mean volume differences were -12%, -3%, -13%, and +10% for VNCConv, VNCPC, CTA-30, and CTA0 compared to TNC. Distribution of CT values on VNCPC showed less difference to TNC than on VNCConv (mean attenuation difference +7% vs. +2%; Euclidean distance of histograms 0.029 vs. 0.016). CONCLUSIONS VNCPC-reconstructions of PCD-CCTA datasets can be used to reliably assess EAT volume with a high accuracy and only minor differences in CT values compared to TNC. Substitution of TNC would significantly decrease patient's radiation dose. KEY POINTS • Measurement of epicardial adipose tissue (EAT) volume and attenuation are feasible on virtual non-contrast (VNC) series with excellent correlation to true non-contrast series (all R2>0.9). • Differences in VNC algorithms have a significant impact on EAT volume and CT attenuation values. • A novel VNC algorithm (VNCPC) enables reliable assessment of EAT volume and attenuation with superior accuracy compared to measurements on conventional VNC- and CCTA-series.
Collapse
|
38
|
Decker JA, O'Doherty J, Schoepf UJ, Todoran TM, Aquino GJ, Brandt V, Baruah D, Fink N, Zsarnoczay E, Flohr T, Schmidt B, Allmendinger T, Risch F, Varga-Szemes A, Emrich T. Stent imaging on a clinical dual-source photon-counting detector CT system-impact of luminal attenuation and sharp kernels on lumen visibility. Eur Radiol 2023; 33:2469-2477. [PMID: 36462045 DOI: 10.1007/s00330-022-09283-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 09/07/2022] [Accepted: 11/04/2022] [Indexed: 12/04/2022]
Abstract
OBJECTIVES To assess the impact of scan modes and reconstruction kernels using a novel dual-source photon-counting detector CT (PCD-CT) on lumen visibility and sharpness of different stent sizes. METHODS A phantom containing six balloon-expandable stents (2.5 to 9 mm diameter) in silicone tubing was scanned on a PCD-CT with standard (0.6 mm and 0.4 mm thicknesses) and ultra-high-resolution (0.2 mm thickness) modes. With the use of increasing contrast medium concentrations, densities of 0, 200, 400, and 600 HU were achieved. Standard-resolution scans were reconstructed using increasing sharpness kernels, using both polyenergetic quantitative soft tissue "conventional" ((Qr40c(0.6 mm), Qr40c(0.4 mm), Qr72c(0.2 mm)) and vascular (Bv) virtual monoenergetic reconstructions (Bv44m(0.4 mm), Bv60m(0.4 mm)) at 70 keV. In-stent lumen visibility, sharpness (max. ΔHU of the stent measured in profile plots), and in-stent noise (standard deviation of HU) were measured. RESULTS In-stent lumen visibility was highest for Qr72c(0.2 mm) (86.5 ± 2.8% to 88.3 ± 2.6%) and in Bv60m(0.4 mm) reconstructions (77.3 ± 2.9 to 82.7 ± 2.5%). Lumen visibility was lowest in the smallest stent (2.5 mm) ranging from 54.1% in Qr40c(0.6 mm) to 74.1% in Qr72c(0.2 mm) and highest in the largest stent (9 mm) ranging from 93.8% in Qr40c(0.6 mm) to 99.1% in the Qr72c(0.2 mm) series. Lumen visibility decreased by 2.1% for every 200-HU increase in lumen attenuation. Max. ΔHU between stents and stent lumen was highest in Qr72c(0.2 mm) (ΔHU 892 ± 504 to 1526 ± 517) and Bv60m(0.4 mm) series (ΔHU 480 ± 357 to 1030 ± 344). Improvement of lumen visibility and sharpness in UHR and Bv60m(0.4 mm) series was strongest in smaller stent sizes. CONCLUSION UHR acquisition mode and sharp reconstruction kernels on a novel PCD-CT system significantly improve in-stent lumen visibility and sharpness-especially for smaller stent sizes. KEY POINTS • In-stent lumen visibility and sharpness of stents significantly improve using sharp reconstruction kernels (Bv60) and ultra-high-resolution mode in photon-counting detector computed tomography. • The observed improvement of stent-lumen visibility was highest in smaller stent sizes.
Collapse
Affiliation(s)
- Josua A Decker
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany
| | - Jim O'Doherty
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Siemens Medical Solutions, Malvern, PA, USA
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.
| | - Thomas M Todoran
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, USA
| | - Gilberto J Aquino
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Verena Brandt
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Cardiology and Angiology, Robert-Bosch Hospital, Stuttgart, Germany
| | - Dhiraj Baruah
- Division of Thoracic Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA
| | - Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Medical Imaging Centre, Semmelweis University, Budapest, Hungary
| | | | | | | | - Franka Risch
- Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Mainz, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany
| |
Collapse
|
39
|
Zsarnoczay E, Fink N, Schoepf UJ, O'Doherty J, Allmendinger T, Hagenauer J, Wolf EV, Griffith JP, Maurovich-Horvat P, Varga-Szemes A, Emrich T. Ultra-high resolution photon-counting coronary CT angiography improves coronary stenosis quantification over a wide range of heart rates - A dynamic phantom study. Eur J Radiol 2023; 161:110746. [PMID: 36821957 DOI: 10.1016/j.ejrad.2023.110746] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 02/01/2023] [Accepted: 02/12/2023] [Indexed: 02/18/2023]
Abstract
PURPOSE To investigate the effect of using photon-counting detector (PCD)-CT with ultra-high resolution (UHR) on stenosis quantification accuracy and blooming artifacts from low to high heart rates in a dynamic motion phantom. METHOD Two vessel phantoms (diameter: 4 mm) containing solid calcified lesions (25%, 50% stenoses), filled with different concentrations of iodine, inside an anthropomorphic thorax phantom attached to a coronary motion simulator were used. Scanning was performed on a PCD-CT system using an ECG-gated mode at UHR and standard resolution (SR) (0.2, 0.6 mm slice thickness, respectively). Images were reconstructed at 60, 80 and 100 beats per minute (bpm) (UHR: Bv56 kernel, quantum iterative reconstruction (QIR) level 3; SR: 55 keV, Bv40 kernel, QIR3). Percent diameter stenosis (PDS) and blooming artifacts were measured by two readers. RESULTS PDS measurements derived from UHR were more accurate than SR for both lesions at every heart rate (p ≤ 0.005 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 57.1% [55.2-59.2] vs. 50.0% [48.5-51.2], at 100 bpm 61.0% [58.6-64.3] vs. 52.4% [51.3-54.3]). Overall mean difference across heart rates and lesions compared to the nominal stenoses was 9.2% (Limit of Agreement (LoA), 2.4%/16.0%) for SR vs. 2.4% (LoA, -2.8%/7.5%) for UHR. Blooming artifacts decreased with UHR compared to SR for both lesions at every heart rate (p < 0.001 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 63.8% [60.6-69.5] vs. 52.5% [50.0-57.5], at 100 bpm 70.2% [64.8-78.1] vs. 56.1% [51.2-60.8]). CONCLUSIONS This motion phantom study demonstrates improved stenosis quantification accuracy and reduced blooming artifacts with UHR-PCD-CT compared to SR, independent of heart rate.
Collapse
Affiliation(s)
- Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; MTA-SE Cardiovascular Imaging Research Group, Medical Imaging Center, Semmelweis University, Korányi Sándor utca 2, Budapest 1083, Hungary.
| | - Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Department of Radiology, University Hospital, LMU Munich, Marchioninistraße 15, Munich 81377, Germany.
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States.
| | - Jim O'Doherty
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Siemens Medical Solutions USA Inc, 40 Liberty Boulevard, Malvern, PA 19355, United States.
| | | | - Junia Hagenauer
- Siemens Healthcare GmbH, Siemensstraße 1, Forchheim 91301, Germany; Faculty of Medicine, Friedrich Alexander University of Erlangen-Nuremberg, Krankenhausstraße 12, Erlangen 91054, Germany.
| | - Elias V Wolf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, Mainz 55131, Germany.
| | - Joseph P Griffith
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States.
| | - Pál Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Medical Imaging Center, Semmelweis University, Korányi Sándor utca 2, Budapest 1083, Hungary.
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States.
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, Mainz 55131, Germany; German Centre for Cardiovascular Research, Partner Site Rhine-Main, Mainz 55131, Germany.
| |
Collapse
|
40
|
Photon Counting Detector CT-Based Virtual Noniodine Reconstruction Algorithm for In Vitro and In Vivo Coronary Artery Calcium Scoring: Impact of Virtual Monoenergetic and Quantum Iterative Reconstructions. Invest Radiol 2023:00004424-990000000-00091. [PMID: 36822677 DOI: 10.1097/rli.0000000000000959] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
OBJECTIVES The aim of this study was to evaluate the impact of virtual monoenergetic imaging (VMI) and quantum iterative reconstruction (QIR) on the accuracy of coronary artery calcium scoring (CACS) using a virtual noniodine (VNI) reconstruction algorithm on a first-generation, clinical, photon counting detector computed tomography system. MATERIALS AND METHODS Coronary artery calcium scoring was evaluated in an anthropomorphic chest phantom simulating 3 different patient sizes by using 2 extension rings (small: 300 × 200 mm, medium: 350 × 250 mm, large: 400 × 300 mm) and in patients (n = 61; final analyses only in patients with coronary calcifications [n = 34; 65.4 ± 10.0 years; 73.5% male]), who underwent nonenhanced and contrast-enhanced, electrocardiogram-gated, cardiac computed tomography on a photon counting detector system. Phantom and patient data were reconstructed using a VNI reconstruction algorithm at different VMI (55-80 keV) and QIR (strength 1-4) levels (CACSVNI). True noncontrast (TNC) scans at 70 keV and QIR "off" were used as reference for phantom and patient studies (CACSTNC). RESULTS In vitro and in vivo CACSVNI showed strong correlation (r > 0.9, P < 0.001 for all) and excellent agreement (intraclass correlation coefficient > 0.9 for all) with CACSTNC at all investigated VMI and QIR levels. Phantom and patient CACSVNI significantly increased with decreasing keV levels (in vitro: from 475.2 ± 26.3 at 80 keV up to 652.5 ± 42.2 at 55 keV; in vivo: from 142.5 [7.4/737.7] at 80 keV up to 248.1 [31.2/1144] at 55 keV; P < 0.001 for all), resulting in an overestimation of CACSVNI at 55 keV compared with CACSTNC at 70 keV in some cases (in vitro: 625.8 ± 24.4; in vivo: 225.4 [35.1/959.7]). In vitro CACS increased with rising QIR at low keV. In vivo scores were significantly higher at QIR 1 compared with QIR 4 only at 60 and 80 keV (60 keV: 220.3 [29.6-1060] vs 219.5 [23.7/1048]; 80 keV: 152.0 [12.0/735.6] vs 142.5 [7.4/737.7]; P < 0.001). CACSVNI was closest to CACSTNC at 60 keV, QIR 2 (+0.1%) in the small; 55 keV, QIR 1 (±0%) in the medium; 55 keV, QIR 4 (-0.1%) in the large phantom; and at 60 keV, QIR 1 (-2.3%) in patients. CONCLUSIONS Virtual monoenergetic imaging reconstructions have a significant impact on CACSVNI. The effects of different QIR levels are less consistent and seem to depend on several individual conditions, which should be further investigated.
Collapse
|
41
|
Baeßler B, Götz M, Antoniades C, Heidenreich JF, Leiner T, Beer M. Artificial intelligence in coronary computed tomography angiography: Demands and solutions from a clinical perspective. Front Cardiovasc Med 2023; 10:1120361. [PMID: 36873406 PMCID: PMC9978503 DOI: 10.3389/fcvm.2023.1120361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 01/25/2023] [Indexed: 02/18/2023] Open
Abstract
Coronary computed tomography angiography (CCTA) is increasingly the cornerstone in the management of patients with chronic coronary syndromes. This fact is reflected by current guidelines, which show a fundamental shift towards non-invasive imaging - especially CCTA. The guidelines for acute and stable coronary artery disease (CAD) of the European Society of Cardiology from 2019 and 2020 emphasize this shift. However, to fulfill this new role, a broader availability in adjunct with increased robustness of data acquisition and speed of data reporting of CCTA is needed. Artificial intelligence (AI) has made enormous progress for all imaging methodologies concerning (semi)-automatic tools for data acquisition and data post-processing, with outreach toward decision support systems. Besides onco- and neuroimaging, cardiac imaging is one of the main areas of application. Most current AI developments in the scenario of cardiac imaging are related to data postprocessing. However, AI applications (including radiomics) for CCTA also should enclose data acquisition (especially the fact of dose reduction) and data interpretation (presence and extent of CAD). The main effort will be to integrate these AI-driven processes into the clinical workflow, and to combine imaging data/results with further clinical data, thus - beyond the diagnosis of CAD- enabling prediction and forecast of morbidity and mortality. Furthermore, data fusing for therapy planning (e.g., invasive angiography/TAVI planning) will be warranted. The aim of this review is to present a holistic overview of AI applications in CCTA (including radiomics) under the umbrella of clinical workflows and clinical decision-making. The review first summarizes and analyzes applications for the main role of CCTA, i.e., to non-invasively rule out stable coronary artery disease. In the second step, AI applications for additional diagnostic purposes, i.e., to improve diagnostic power (CAC = coronary artery classifications), improve differential diagnosis (CT-FFR and CT perfusion), and finally improve prognosis (again CAC plus epi- and pericardial fat analysis) are reviewed.
Collapse
Affiliation(s)
- Bettina Baeßler
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Michael Götz
- Division of Experimental Radiology, Department for Diagnostic and Interventional Radiology, University Hospital Ulm, Ulm, Germany
| | - Charalambos Antoniades
- British Heart Foundation Chair of Cardiovascular Medicine, Cardiovascular Medicine, University of Oxford, Oxford, United Kingdom
| | - Julius F. Heidenreich
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
| | - Tim Leiner
- Department of Radiology, Mayo Clinic, Rochester, MN, United States
- Department of Radiology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Meinrad Beer
- Department for Diagnostic and Interventional Radiology, University Hospital Ulm, Ulm, Germany
| |
Collapse
|
42
|
Langenbach IL, Wienemann H, Klein K, Scholtz JE, Pennig L, Langzam E, Pahn G, Holz JA, Maintz D, Naehle CP, Langenbach MC. Coronary calcium scoring using virtual non-contrast reconstructions on a dual-layer spectral CT system: Feasibility in the clinical practice. Eur J Radiol 2023; 159:110681. [PMID: 36592582 DOI: 10.1016/j.ejrad.2022.110681] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 12/22/2022] [Accepted: 12/23/2022] [Indexed: 12/27/2022]
Abstract
PURPOSE To evaluate the clinical applicability of a prototype virtual non-contrast (VNC) reconstruction algorithm based on coronary CT angiography (cCTA) to assess calcified coronary plaques by calcium scoring (CACS). METHODS Eighty consecutive patients suspected of coronary artery disease were retrospectively included. All patients underwent a cardiac CT using a dual-layer spectral-detector CT system. The standardized acquisition protocol included unenhanced CACS and cCTA. Datasets were acquired using 120 keV. VNC-reconstructions were calculated from the cCTA images at 2.5 mm (VNC group 1), 2.5 of 0.9 mm (group 2), and 0.9 mm (group 3) slice thickness. We compared the Agatston score and Coronary Artery Calcium Data and Reporting System (CAC-DRS) of all VNC reconstructions with the true non-contrast (TNC)-dataset as the gold standard. RESULTS In total, 73 patients were evaluated. Fifty patients (68.5 %) had a CACS > 0 based on TNC. We found a significant difference in the Agatston score comparing all VNC-reconstructions (1: 1.35, 2: 3.7, 3: 10.4) with the TNC dataset (3.8) (p < 0.001). Correlation analysis of the datasets showed an excellent correlation of the TNC results with the different VNC-reconstructions (r = 0.904-0.974, p < 0.001) with a slope of 1.89-2.53. Mean differences and limits of agreement by Bland-Altman analysis between TNC and group 1 were 83 and -196 to 362, respectively. By using the VNC-reconstructions, in group 1 23 patients (31.5 %), in group 2 10 (13.7 %), and in group 3 23 (31.5 %) were reclassified according to CAC-DRS compared to TNC. Classification according to CAC-DRS revealed a significant difference between TNC and group 1 (p = 0.024) and no significance compared to groups 2 and 3 (p = 0.670 and 0.273). CONCLUSION The investigated VNC reconstruction algorithm of routine cCTA allows the detection and evaluation of coronary calcium burden without the requirement for an additional acquisition of an unenhanced CT scan for CACS and, therefore, a reduction of radiation exposure.
Collapse
Affiliation(s)
- I L Langenbach
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany; Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
| | - H Wienemann
- Clinic III for Internal Medicine, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - K Klein
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - J E Scholtz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Frankfurt, University of Frankfurt, Frankfurt, Germany
| | - L Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - E Langzam
- Philips Healthcare, Best, the Netherlands
| | - G Pahn
- Philips CT Clinical Science, Hamburg, Germany
| | - J A Holz
- Department of Radiation Oncology, University Hospital Bonn, University of Bonn, Bonn, Germany
| | - D Maintz
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - C P Naehle
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany; Radiologische Allianz, Hamburg, Germany
| | - M C Langenbach
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany; Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
43
|
Reduced Iodinated Contrast Media Administration in Coronary CT Angiography on a Clinical Photon-Counting Detector CT System: A Phantom Study Using a Dynamic Circulation Model. Invest Radiol 2023; 58:148-155. [PMID: 36165932 DOI: 10.1097/rli.0000000000000911] [Citation(s) in RCA: 30] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE The aim of this study was to evaluate strategies to reduce contrast media volumes for coronary computed tomography (CT) angiography on a clinical first-generation dual-source photon-counting detector (PCD)-CT system using a dynamic circulation phantom. MATERIALS AND METHODS Coronary CT angiograph is an established method for the assessment of coronary artery disease that relies on the administration of iodinated contrast media. Reduction of contrast media volumes while maintaining diagnostic image quality is desirable. In this study, a dynamic phantom containing a 3-dimensional-printed model of the thoracic aorta and coronary arteries was evaluated using a clinical contrast injection protocol with stepwise reduced contrast agent concentrations (100%, 75%, 50%, 40%, 30%, and 20% contrast media content of the same 50 mL bolus, resulting in iodine delivery rates of 1.5, 1.1, 0.7, 0.6, 0.4 and 0.3 gl/s) on a first-generation, dual-source PCD-CT. Polychromatic images (T3D) and virtual monoenergetic images were reconstructed in the range of 40 to 70 keV in 5-keV steps. Attenuation and noise were measured in the coronary arteries and background material and the contrast-to-noise ratio (CNR) were calculated. Attenuation of 350 HU and a CNR of the reference protocol at 70 keV were regarded as sufficient for simulation of diagnostic purposes. Vessel sharpness and noise power spectra were analyzed for the aforementioned reconstructions. RESULTS The standard clinical contrast protocol (bolus with 100% contrast) yielded diagnostic coronary artery attenuation for all tested reconstructions (>398 HU). A 50% reduction in contrast media concentration demonstrated sufficient attenuation of the coronary arteries at 40 to 55 keV (>366 HU). Virtual monoenergetic image reconstructions of 40 to 45 and 40 keV allowed satisfactory attenuation of the coronary arteries for contrast concentrations of 40% and 30% of the original protocol. A reduction of contrast agent concentration to 20% of the initial concentration provided insufficient attenuation in the target vessels for all reconstructions. The highest CNR was found for virtual monoenergetic reconstructions at 40 keV for all contrast media injection protocols, yielding a sufficient CNR at a 50% reduction of contrast agent concentration. CONCLUSIONS Using virtual monoenergetic image reconstructions at 40 keV on a dual-source PCD-CT system, contrast media concentration could be reduced by 50% to obtain diagnostic attenuation and objective image quality for coronary CT angiography in a dynamic vessel phantom. These initial feasibility study results have to be validated in clinical studies.
Collapse
|
44
|
Wolf EV, Halfmann MC, Schoepf UJ, Zsarnoczay E, Fink N, Griffith JP, Aquino GJ, Willemink MJ, O’Doherty J, Hell MM, Suranyi P, Kabakus IM, Baruah D, Varga-Szemes A, Emrich T. Intra-individual comparison of coronary calcium scoring between photon counting detector- and energy integrating detector-CT: Effects on risk reclassification. Front Cardiovasc Med 2023; 9:1053398. [PMID: 36741832 PMCID: PMC9892711 DOI: 10.3389/fcvm.2022.1053398] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 12/28/2022] [Indexed: 01/20/2023] Open
Abstract
Purpose To compare coronary artery calcium volume and score (CACS) between photon-counting detector (PCD) and conventional energy integrating detector (EID) computed tomography (CT) in a phantom and prospective patient study. Methods A commercially available CACS phantom was scanned with a standard CACS protocol (120 kVp, slice thickness/increment 3/1.5 mm, and a quantitative Qr36 kernel), with filtered back projection on the EID-CT, and with monoenergetic reconstruction at 70 keV and quantum iterative reconstruction off on the PCD-CT. The same settings were used to prospectively acquire data in patients (n = 23, 65 ± 12.1 years), who underwent PCD- and EID-CT scans with a median of 5.5 (3.0-12.5) days between the two scans in the period from August 2021 to March 2022. CACS was quantified using a commercially available software solution. A regression formula was obtained from the aforementioned comparison and applied to simulate risk reclassification in a pre-existing cohort of 514 patients who underwent a cardiac EID-CT between January and December 2021. Results Based on the phantom experiment, CACS PCD-CT showed a more accurate measurement of the reference CAC volumes (overestimation of physical volumes: PCD-CT 66.1 ± 1.6% vs. EID-CT: 77.2 ± 0.5%). CACS EID-CT and CACS PCD-CT were strongly correlated, however, the latter measured significantly lower values in the phantom (CACS PCD-CT : 60.5 (30.2-170.3) vs CACS EID-CT 74.7 (34.6-180.8), p = 0.0015, r = 0.99, mean bias -9.7, Limits of Agreement (LoA) -36.6/17.3) and in patients (non-significant) (CACS PCD-CT : 174.3 (11.1-872.7) vs CACS EID-CT 218.2 (18.5-876.4), p = 0.10, r = 0.94, mean bias -41.1, LoA -315.3/232.5). The systematic lower measurements of Agatston score on PCD-CT system led to reclassification of 5.25% of our simulated patient cohort to a lower classification class. Conclusion CACS PCD-CT is feasible and correlates strongly with CACS EID-CT , however, leads to lower CACS values. PCD-CT may provide results that are more accurate for CACS than EID-CT.
Collapse
Affiliation(s)
- Elias V. Wolf
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany,Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Moritz C. Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany,German Centre for Cardiovascular Research, Partner Site Rhine-Main, Mainz, Germany
| | - U. Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States,MTA-SE Cardiovascular Imaging Research Group, Medical Imaging Center, Semmelweis University, Budapest, Hungary
| | - Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States,Department of Radiology, University Hospital Munich, LMU Munich, Munich, Germany
| | - Joseph P. Griffith
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Gilberto J. Aquino
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Martin J. Willemink
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, United States,Segmed, Inc., Palo Alto, CA, United States
| | - Jim O’Doherty
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States,Siemens Medical Solutions USA, Inc., Malvern, PA, United States
| | - Michaela M. Hell
- Department of Cardiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Pal Suranyi
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Ismael M. Kabakus
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Dhiraj Baruah
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States
| | - Tilman Emrich
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany,Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, United States,German Centre for Cardiovascular Research, Partner Site Rhine-Main, Mainz, Germany,*Correspondence: Tilman Emrich,
| |
Collapse
|
45
|
Mergen V, Eberhard M, Manka R, Euler A, Alkadhi H. First in-human quantitative plaque characterization with ultra-high resolution coronary photon-counting CT angiography. Front Cardiovasc Med 2022; 9:981012. [PMID: 36148053 PMCID: PMC9485480 DOI: 10.3389/fcvm.2022.981012] [Citation(s) in RCA: 38] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 08/18/2022] [Indexed: 11/13/2022] Open
Abstract
PurposeTo assess the effect of ultra-high-resolution coronary CT angiography (CCTA) with photon-counting detector (PCD) CT on quantitative coronary plaque characterization.Materials and methodsIn this IRB-approved study, 22 plaques of 20 patients (7 women; mean age 77 ± 8 years, mean body mass index 26.1 ± 3.6 kg/m2) undergoing electrocardiography (ECG)-gated ultra-high-resolution CCTA with PCD-CT were included. Images were reconstructed with a smooth (Bv40) and a sharp (Bv64) vascular kernel, with quantum iterative reconstruction (strength level 4), and using a slice thickness of 0.6, 0.4, and 0.2 mm, respectively (field-of-view 200 mm × 200 mm, matrix size 512 × 512 pixels). Reconstructions with the Bv40 kernel and slice thickness of 0.6 mm served as the reference standard. After identification of a plaque in coronary arteries with a vessel diameter ≥2 mm, plaque composition was determined using a dedicated, semi-automated plaque quantification software. Total plaque, calcified, fibrotic, and lipid-rich plaque components were quantified in all datasets.ResultsMedian plaque volume was highest (23.5 mm3, interquartiles 17.9–34.3 mm3) for reconstructions with the reference standard and lowest for ultra-high-resolution reconstructions with a slice thickness of 0.2 mm and the Bv64 kernel (18.1 mm3, interquartiles 14.1–25.8 mm3, p < 0.001). Reconstructions with the reference standard showed largest calcified (85.1%, interquartiles 76.4–91.1%) and smallest lipid-rich plaque components (0.5%, interquartiles 0.0–1.5%). Smallest calcified plaque components (75.2%, interquartiles 69.9–80.8%) and largest lipid-rich components (6.7%, interquartiles 5.1–8.4%) were found for ultra-high-resolution reconstructions with a slice thickness of 0.2 mm and the Bv64 kernel. At an identical slice thickness, volume of calcified components was always lower, and volume of lipid-rich components was always higher for reconstructions with the Bv64 kernel compared with reconstructions with the Bv40 kernel (all, p < 0.001).ConclusionThis patient study indicates significant differences of ultra-high-resolution scanning with PCD-CT on quantitative coronary plaque characterization. Reduced blooming artifacts may allow improved visualization of fibrotic and lipid-rich plaque components with the ultra-high-resolution mode of PCD-CT.
Collapse
Affiliation(s)
- Victor Mergen
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Eberhard
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Robert Manka
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- Department of Cardiology, University Heart Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - André Euler
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- *Correspondence: Hatem Alkadhi,
| |
Collapse
|
46
|
Fink N, Joseph Schoepf U. Photon Counting Detectors – Not Only a Technical Breakthrough, But Also a New Era in Patient Care? Eur J Radiol 2022; 154:110435. [DOI: 10.1016/j.ejrad.2022.110435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 07/02/2022] [Indexed: 11/03/2022]
|