1
|
Mireles M, Jiménez-Valerio G, Morales-Dalmau J, Johansson JD, Martínez-Lozano M, Vidal-Rosas EE, Navarro-Pérez V, Busch DR, Casanovas O, Durduran T, Vilches C. Prediction of the response to antiangiogenic sunitinib therapy by non-invasive hybrid diffuse optics in renal cell carcinoma. BIOMEDICAL OPTICS EXPRESS 2024; 15:5773-5789. [PMID: 39421783 PMCID: PMC11482189 DOI: 10.1364/boe.532052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 08/21/2024] [Accepted: 08/25/2024] [Indexed: 10/19/2024]
Abstract
In this work, broadband diffuse reflectance spectroscopy (DRS) and diffuse correlation spectroscopy (DCS) were used to quantify deep tissue hemodynamics in a patient-derived orthotopic xenograft mouse model of clear cell renal cancer undergoing antiangiogenic treatment. A cohort of twenty-two mice were treated with sunitinib and compared to thirteen control untreated mice, and monitored by DRS/DCS. A reduction in total hemoglobin concentration (THC, p = 0.03), oxygen saturation (SO2, p = 0.03) and blood flow index (BFI, p = 0.02) was observed over the treatment course. Early changes in tumor microvascular blood flow and total hemoglobin concentration were correlated with the final microvessel density (p = 0.014) and tumor weight (p = 0.024), respectively. Higher pre-treatment tumor microvascular blood flow was observed in non-responder mice with respect to responder mice, which was statistically predictive of the tumor intrinsic resistance (p = 0.01). This hybrid diffuse optical technique provides a method for predicting tumor intrinsic resistance to antiangiogenic therapy and could be used as predictive biomarker of response to antiangiogenic therapies in pre-clinical models.
Collapse
Affiliation(s)
- Miguel Mireles
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Barcelona, Spain
- Computational Optics and Translational Imaging Lab, Northeastern University, Boston, Massachusetts 02115, USA
| | - Gabriela Jiménez-Valerio
- Computational Optics and Translational Imaging Lab, Northeastern University, Boston, Massachusetts 02115, USA
| | - Jordi Morales-Dalmau
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Barcelona, Spain
| | - Johannes D. Johansson
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Barcelona, Spain
- Department of Biomedical Engineering, Linköping University, SE-581 83 Linköping, Sweden
| | - Mar Martínez-Lozano
- Tumor Angiogenesis Group, ProCURE, Catalan Institute of Oncology - IDIBELL, 08908 L’Hospitalet de Llobregat, Spain
| | - Ernesto E. Vidal-Rosas
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Barcelona, Spain
- Digital Health and Biomedical Engineering, School of Electronics and Computer Science, University of Southampton, SO17 1BJ Southampton, UK
| | - Valentí Navarro-Pérez
- Clinical Research Unit, Institut Català d’Oncologia, 08908 L’Hospitalet de Llobregat, Spain
| | - David R. Busch
- University of Texas Southwestern Medical Center, Departments of Anesthesiology and Pain Management, Neurology, and Biomedical Engineering Dallas, Texas 75390-9003, USA
| | - Oriol Casanovas
- Tumor Angiogenesis Group, ProCURE, Catalan Institute of Oncology - IDIBELL, 08908 L’Hospitalet de Llobregat, Spain
| | - Turgut Durduran
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Barcelona, Spain
- ICREA - Institució Catalana de Recerca i Estudis Avançats, 08010 Barcelona, Spain
| | - Clara Vilches
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Barcelona, Spain
| |
Collapse
|
2
|
Robbins CM, Qian K, Zhang YJ, Kainerstorfer JM. Monte Carlo simulation of spatial frequency domain imaging for breast tumors during compression. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:096001. [PMID: 39282216 PMCID: PMC11399730 DOI: 10.1117/1.jbo.29.9.096001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Revised: 08/16/2024] [Accepted: 08/19/2024] [Indexed: 09/18/2024]
Abstract
Significance Near-infrared optical imaging methods have shown promise for monitoring response to neoadjuvant chemotherapy (NAC) for breast cancer, with endogenous contrast coming from oxy- and deoxyhemoglobin. Spatial frequency domain imaging (SFDI) could be used to detect this contrast in a low-cost and portable format, but it has limited imaging depth. It is possible that local tissue compression could be used to reduce the effective tumor depth. Aim To evaluate the potential of SFDI for therapy response prediction, we aim to predict how changes to tumor size, stiffness, and hemoglobin concentration would be reflected in contrast measured by SFDI under tissue compression. Approach Finite element analysis of compression on an inclusion-containing soft material is combined with Monte Carlo simulation to predict the measured optical contrast. Results When the effect of compression on blood volume is not considered, contrast gain from compression increases with the size and stiffness of the inclusion and decreases with the inclusion depth. With a model of reduction of blood volume from compression, compression reduces imaging contrast, an effect that is greater for larger inclusions and stiffer inclusions at shallower depths. Conclusions This computational modeling study represents a first step toward tracking tumor changes induced by NAC using SFDI and local compression.
Collapse
Affiliation(s)
- Constance M Robbins
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
- University of Pittsburgh, Department of Radiology, Pittsburgh, Pennsylvania, United States
| | - Kuanren Qian
- Carnegie Mellon University, Department of Mechanical Engineering, Pittsburgh, Pennsylvania, United States
| | - Yongjie Jessica Zhang
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
- Carnegie Mellon University, Department of Mechanical Engineering, Pittsburgh, Pennsylvania, United States
| | - Jana M Kainerstorfer
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
- Carnegie Mellon University, Neuroscience Institute, Pittsburgh, Pennsylvania, United States
| |
Collapse
|
3
|
Wang Q, Pan M, Kreiss L, Samaei S, Carp SA, Johansson JD, Zhang Y, Wu M, Horstmeyer R, Diop M, Li DDU. A comprehensive overview of diffuse correlation spectroscopy: Theoretical framework, recent advances in hardware, analysis, and applications. Neuroimage 2024; 298:120793. [PMID: 39153520 DOI: 10.1016/j.neuroimage.2024.120793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Revised: 07/23/2024] [Accepted: 08/14/2024] [Indexed: 08/19/2024] Open
Abstract
Diffuse correlation spectroscopy (DCS) is a powerful tool for assessing microvascular hemodynamic in deep tissues. Recent advances in sensors, lasers, and deep learning have further boosted the development of new DCS methods. However, newcomers might feel overwhelmed, not only by the already-complex DCS theoretical framework but also by the broad range of component options and system architectures. To facilitate new entry to this exciting field, we present a comprehensive review of DCS hardware architectures (continuous-wave, frequency-domain, and time-domain) and summarize corresponding theoretical models. Further, we discuss new applications of highly integrated silicon single-photon avalanche diode (SPAD) sensors in DCS, compare SPADs with existing sensors, and review other components (lasers, sensors, and correlators), as well as data analysis tools, including deep learning. Potential applications in medical diagnosis are discussed and an outlook for the future directions is provided, to offer effective guidance to embark on DCS research.
Collapse
Affiliation(s)
- Quan Wang
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom
| | - Mingliang Pan
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom
| | - Lucas Kreiss
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Saeed Samaei
- Department of Medical and Biophysics, Schulich School of Medical & Dentistry, Western University, London, Ontario, Canada; Lawson Health Research Institute, Imaging Program, London, Ontario, Canada
| | - Stefan A Carp
- Massachusetts General Hospital, Optics at Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School, Charlestown, MA, United States
| | | | - Yuanzhe Zhang
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom
| | - Melissa Wu
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Roarke Horstmeyer
- Department of Biomedical Engineering, Duke University, Durham, NC, United States
| | - Mamadou Diop
- Department of Medical and Biophysics, Schulich School of Medical & Dentistry, Western University, London, Ontario, Canada; Lawson Health Research Institute, Imaging Program, London, Ontario, Canada
| | - David Day-Uei Li
- Department of Biomedical Engineering, Faculty of Engineering, University of Strathclyde, Glasgow, United Kingdom.
| |
Collapse
|
4
|
Mule N, Maffeis G, Cubeddu R, Santangelo C, Bianchini G, Panizza P, Taroni P. Monitoring of neoadjuvant chemotherapy through time domain diffuse optics: breast tissue composition changes and collagen discriminative potential. BIOMEDICAL OPTICS EXPRESS 2024; 15:4842-4858. [PMID: 39346975 PMCID: PMC11427201 DOI: 10.1364/boe.527968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 06/26/2024] [Accepted: 06/26/2024] [Indexed: 10/01/2024]
Abstract
The purpose of this clinical study is to test a broad spectral range (635-1060 nm) time-domain diffuse optical spectroscopy in monitoring the response of breast cancer patients to neoadjuvant chemotherapy (NAC). The broadband operation allows us to fully analyze tissue composition in terms of hemoglobin, water, lipids and collagen concentration, which has never been systematically studied until now during the course of therapy. Patients are subjected to multiple breast optical imaging sessions, each one performed at different stages of NAC, both on tumor-bearing and contralateral healthy breasts. We correlate the optical results with conventional imaging techniques and pathological response. Preliminary outcomes on 10 patients' data show an average significant reduction in the concentrations of oxy-hemoglobin (-53%, p = 0.0020), collagen (-36%, p = 0.0039) and water (-15%, p = 0.0195), and increase in lipids (+39%, p = 0.0137) from baseline to the end of therapy in the tumor-bearing breast of patients who responded to therapy at least partially. With respect to scattering, the scattering amplitude, a, increases slightly (+15%, p = 0.0039) by the end of the therapy compared to the baseline, while the scattering slope, b, shows no significant change (+4%, p = 0.9219). Some change in the constituents' concentrations was also noticed in the contralateral healthy breast, even though it was significant only for oxy-hemoglobin concentration. We observed that collagen seems to be the only component distinguishing between complete and partial responders by the end of 2-3 weeks from the baseline. In the complete responder group, collagen significantly decreased after 2-3 weeks with respect to baseline (p = 0.0423). While the partial responder group also showed a decrease, it did not reach statistical significance (p = 0.1012). This suggests that collagen could serve as a potential biomarker to measure NAC effectiveness early during treatment. Even though obtained on a small group of patients, these initial results are consistent with those of standard medical modalities and highlight the sensitivity of the technique to changes that occur in breast composition during NAC.
Collapse
Affiliation(s)
- Nikhitha Mule
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano, Italy
- Scientific Institute (IRCCS) Ospedale San Raffaele, Breast Imaging Unit, Via Olgettina 60, 20132 Milano, Italy
| | - Giulia Maffeis
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano, Italy
| | - Rinaldo Cubeddu
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano, Italy
| | - Carolina Santangelo
- Scientific Institute (IRCCS) Ospedale San Raffaele, Breast Imaging Unit, Via Olgettina 60, 20132 Milano, Italy
| | - Giampaolo Bianchini
- Scientific Institute (IRCCS) Ospedale San Raffaele, Department of Medical Oncology, Via Olgettina 60, 20132 Milano, Italy
- School of Medicine and Surgery, Università Vita-Salute San Raffaele, Via Olgettina 60, 20132 Milano, Italy
| | - Pietro Panizza
- Scientific Institute (IRCCS) Ospedale San Raffaele, Breast Imaging Unit, Via Olgettina 60, 20132 Milano, Italy
| | - Paola Taroni
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano, Italy
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| |
Collapse
|
5
|
Deng B, Muldoon A, Cormier J, Mercaldo ND, Niehoff E, Moffett N, Saksena MA, Isakoff SJ, Carp SA. Functional hemodynamic imaging markers for the prediction of pathological outcomes in breast cancer patients treated with neoadjuvant chemotherapy. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:066001. [PMID: 38737790 PMCID: PMC11088438 DOI: 10.1117/1.jbo.29.6.066001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 04/12/2024] [Accepted: 04/12/2024] [Indexed: 05/14/2024]
Abstract
Significance Achieving pathologic complete response (pCR) after neoadjuvant chemotherapy (NACT) is a significant predictor of increased likelihood of survival in breast cancer patients. Early prediction of pCR is of high clinical value as it could allow personalized adjustment of treatment regimens in non-responding patients for improved outcomes. Aim We aim to assess the association between hemoglobin-based functional imaging biomarkers derived from diffuse optical tomography (DOT) and the pathological outcome represented by pCR at different timepoints along the course of NACT. Approach Twenty-two breast cancer patients undergoing NACT were enrolled in a multimodal DOT and X-ray digital breast tomosynthesis (DBT) imaging study in which their breasts were imaged at different compression levels. Logistic regressions were used to study the associations between DOT-derived imaging markers evaluated after the first and second cycles of chemotherapy, respectively, with pCR status determined after the conclusion of NACT at the time of surgery. Receiver operating characteristic curve analysis was also used to explore the predictive performance of selected DOT-derived markers. Results Normalized tumor HbT under half compression was significantly lower in the pCR group compared to the non-pCR group after two chemotherapy cycles (p = 0.042 ). In addition, the change in normalized tumor StO 2 upon reducing compression from full to half mammographic force was identified as another potential indicator of pCR at an earlier time point, i.e., after the first chemo cycle (p = 0.038 ). Exploratory predictive assessments showed that AUCs using DOT-derived functional imaging markers as predictors reach as high as 0.75 and 0.71, respectively, after the first and second chemo cycle, compared to AUCs of 0.50 and 0.53 using changes in tumor size measured on DBT and MRI. Conclusions These findings suggest that breast DOT could be used to assist response assessment in women undergoing NACT, a critical but unmet clinical need, and potentially enable personalized adjustments of treatment regimens.
Collapse
Affiliation(s)
- Bin Deng
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Boston, Massachusetts, United States
| | - Ailis Muldoon
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
| | - Jayne Cormier
- Massachusetts General Hospital, Breast Imaging Division, Department of Radiology, Boston, Massachusetts, United States
| | - Nathaniel D. Mercaldo
- Harvard Medical School, Boston, Massachusetts, United States
- Massachusetts General Hospital, Institute for Technology Assessment, Boston, Massachusetts, United States
| | - Elizabeth Niehoff
- Massachusetts General Hospital, Cancer Center, Boston, Massachusetts, United States
| | - Natalie Moffett
- Massachusetts General Hospital, Cancer Center, Boston, Massachusetts, United States
| | - Mansi A. Saksena
- Harvard Medical School, Boston, Massachusetts, United States
- Massachusetts General Hospital, Breast Imaging Division, Department of Radiology, Boston, Massachusetts, United States
| | - Steven J. Isakoff
- Harvard Medical School, Boston, Massachusetts, United States
- Massachusetts General Hospital, Cancer Center, Boston, Massachusetts, United States
| | - Stefan A. Carp
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Boston, Massachusetts, United States
| |
Collapse
|
6
|
Kobayashi Frisk L, Verma M, Bešlija F, Lin CHP, Patil N, Chetia S, Trobaugh JW, Culver JP, Durduran T. Comprehensive workflow and its validation for simulating diffuse speckle statistics for optical blood flow measurements. BIOMEDICAL OPTICS EXPRESS 2024; 15:875-899. [PMID: 38404339 PMCID: PMC10890893 DOI: 10.1364/boe.502421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 12/19/2023] [Accepted: 12/20/2023] [Indexed: 02/27/2024]
Abstract
Diffuse optical methods including speckle contrast optical spectroscopy and tomography (SCOS and SCOT), use speckle contrast (κ) to measure deep blood flow. In order to design practical systems, parameters such as signal-to-noise ratio (SNR) and the effects of limited sampling of statistical quantities, should be considered. To that end, we have developed a method for simulating speckle contrast signals including effects of detector noise. The method was validated experimentally, and the simulations were used to study the effects of physical and experimental parameters on the accuracy and precision of κ. These results revealed that systematic detector effects resulted in decreased accuracy and precision of κ in the regime of low detected signals. The method can provide guidelines for the design and usage of SCOS and/or SCOT instruments.
Collapse
Affiliation(s)
- Lisa Kobayashi Frisk
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Manish Verma
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Faruk Bešlija
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Chen-Hao P. Lin
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63110, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Nishighanda Patil
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Sumana Chetia
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Jason W. Trobaugh
- Department of Electrical and Systems Engineering, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Joseph P. Culver
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63110, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110, USA
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| |
Collapse
|
7
|
Cortese L, Fernández Esteberena P, Zanoletti M, Lo Presti G, Aranda Velazquez G, Ruiz Janer S, Buttafava M, Renna M, Di Sieno L, Tosi A, Dalla Mora A, Wojtkiewicz S, Dehghani H, de Fraguier S, Nguyen-Dinh A, Rosinski B, Weigel UM, Mesquida J, Squarcia M, Hanzu FA, Contini D, Mora Porta M, Durduran T. In vivocharacterization of the optical and hemodynamic properties of the human sternocleidomastoid muscle through ultrasound-guided hybrid near-infrared spectroscopies. Physiol Meas 2023; 44:125010. [PMID: 38061053 DOI: 10.1088/1361-6579/ad133a] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 12/07/2023] [Indexed: 12/28/2023]
Abstract
Objective.In this paper, we present a detailedin vivocharacterization of the optical and hemodynamic properties of the human sternocleidomastoid muscle (SCM), obtained through ultrasound-guided near-infrared time-domain and diffuse correlation spectroscopies.Approach.A total of sixty-five subjects (forty-nine females, sixteen males) among healthy volunteers and thyroid nodule patients have been recruited for the study. Their SCM hemodynamic (oxy-, deoxy- and total hemoglobin concentrations, blood flow, blood oxygen saturation and metabolic rate of oxygen extraction) and optical properties (wavelength dependent absorption and reduced scattering coefficients) have been measured by the use of a novel hybrid device combining in a single unit time-domain near-infrared spectroscopy, diffuse correlation spectroscopy and simultaneous ultrasound imaging.Main results.We provide detailed tables of the results related to SCM baseline (i.e. muscle at rest) properties, and reveal significant differences on the measured parameters due to variables such as side of the neck, sex, age, body mass index, depth and thickness of the muscle, allowing future clinical studies to take into account such dependencies.Significance.The non-invasive monitoring of the hemodynamics and metabolism of the sternocleidomastoid muscle during respiration became a topic of increased interest partially due to the increased use of mechanical ventilation during the COVID-19 pandemic. Near-infrared diffuse optical spectroscopies were proposed as potential practical monitors of increased recruitment of SCM during respiratory distress. They can provide clinically relevant information on the degree of the patient's respiratory effort that is needed to maintain an optimal minute ventilation, with potential clinical application ranging from evaluating chronic pulmonary diseases to more acute settings, such as acute respiratory failure, or to determine the readiness to wean from invasive mechanical ventilation.
Collapse
Affiliation(s)
- Lorenzo Cortese
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, E-08860 Castelldefels (Barcelona), Spain
| | - Pablo Fernández Esteberena
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, E-08860 Castelldefels (Barcelona), Spain
| | - Marta Zanoletti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, E-08860 Castelldefels (Barcelona), Spain
- Politecnico di Milano, Dipartimento di Fisica, I-20133 Milano, Italy
| | - Giuseppe Lo Presti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, E-08860 Castelldefels (Barcelona), Spain
| | | | - Sabina Ruiz Janer
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, E-08036 Barcelona, Spain
| | - Mauro Buttafava
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, I-20133 Milano, Italy
- Now at PIONIRS s.r.l., I-20124 Milano, Italy
| | - Marco Renna
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, I-20133 Milano, Italy
- Now at Athinoula A. Martinos Center for Biomedical Imaging, MGH, Harvard Medical School, Charlestown, MA 02129, United States of America
| | - Laura Di Sieno
- Politecnico di Milano, Dipartimento di Fisica, I-20133 Milano, Italy
| | - Alberto Tosi
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, I-20133 Milano, Italy
| | | | - Stanislaw Wojtkiewicz
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, United Kingdom
- Now at Nalecz Institute of Biocybernetics and Biomedical Engineering, 02-109 Warsaw, Poland
| | - Hamid Dehghani
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, United Kingdom
| | | | | | | | - Udo M Weigel
- HemoPhotonics S.L., E-08860 Castelldefels (Barcelona), Spain
| | - Jaume Mesquida
- Área de Crítics, Parc Taulí Hospital Universitari, E-08208 Sabadell, Spain
| | - Mattia Squarcia
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, E-08036 Barcelona, Spain
- Neuroradiology Department, Hospital Clínic of Barcelona, E-08036 Barcelona, Spain
| | - Felicia A Hanzu
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, E-08036 Barcelona, Spain
- Endocrinology and Nutrition Department, Hospital Clínic of Barcelona, E-08036 Barcelona, Spain
- Centro de Investigación Biomédica en Red Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), E-28029 Madrid, Spain
| | - Davide Contini
- Politecnico di Milano, Dipartimento di Fisica, I-20133 Milano, Italy
| | - Mireia Mora Porta
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, E-08036 Barcelona, Spain
- Endocrinology and Nutrition Department, Hospital Clínic of Barcelona, E-08036 Barcelona, Spain
- Centro de Investigación Biomédica en Red Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), E-28029 Madrid, Spain
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, E-08860 Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), E-08010 Barcelona, Spain
| |
Collapse
|
8
|
Zhang J, Zhang L, Liu Z, Zhang Y, Liu D, Jia M, Gao F. Tikhonov regularization-based extended Kalman filter technique for robust and accurate reconstruction in diffuse optical tomography. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2023; 40:10-20. [PMID: 36607070 DOI: 10.1364/josaa.476795] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Accepted: 11/09/2022] [Indexed: 06/17/2023]
Abstract
Diffuse optical tomography (DOT) is a non-invasive imaging modality that uses near-infrared light to probe the optical properties of tissue. In conventionally used deterministic methods for DOT inversion, the measurement errors were not taken into account, resulting in unsatisfactory noise robustness and, consequently, affecting the DOT image reconstruction quality. In order to overcome this defect, an extended Kalman filter (EKF)-based DOT reconstruction algorithm was introduced first, which improved the reconstruction results by incorporating a priori information and measurement errors to the model. Further, to mitigate the instability caused by the ill-condition of the observation matrix in the tomographic imaging problem, a new, to the best of our knowledge, estimation algorithm was derived by incorporating Tikhonov regularization to the EKF method. To verify the effectiveness of the EKF algorithm and Tikhonov regularization-based EKF algorithm for DOT imaging, a series of numerical simulations and phantom experiments were conducted, and the experimental results were quantitatively evaluated and compared with two conventionally used deterministic methods involving the algebraic reconstruction technique and Levenberg-Marquardt algorithm. The results show that the two EKF-based algorithms can accurately estimate the location and size of the target, and the imaging accuracy and noise robustness are obviously improved. Furthermore, the Tikhonov regularization-based EKF obtained optimal parameter estimations, especially under the circumstance of low absorption contrast (1.2) and high noise level (10%).
Collapse
|
9
|
Taylor-Williams M, Spicer G, Bale G, Bohndiek SE. Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220074VR. [PMID: 35922891 PMCID: PMC9346606 DOI: 10.1117/1.jbo.27.8.080901] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/27/2022] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE Measurement and imaging of hemoglobin oxygenation are used extensively in the detection and diagnosis of disease; however, the applied instruments vary widely in their depth of imaging, spatiotemporal resolution, sensitivity, accuracy, complexity, physical size, and cost. The wide variation in available instrumentation can make it challenging for end users to select the appropriate tools for their application and to understand the relative limitations of different methods. AIM We aim to provide a systematic overview of the field of hemoglobin imaging and sensing. APPROACH We reviewed the sensing and imaging methods used to analyze hemoglobin oxygenation, including pulse oximetry, spectral reflectance imaging, diffuse optical imaging, spectroscopic optical coherence tomography, photoacoustic imaging, and diffuse correlation spectroscopy. RESULTS We compared and contrasted the ability of different methods to determine hemoglobin biomarkers such as oxygenation while considering factors that influence their practical application. CONCLUSIONS We highlight key limitations in the current state-of-the-art and make suggestions for routes to advance the clinical use and interpretation of hemoglobin oxygenation information.
Collapse
Affiliation(s)
- Michaela Taylor-Williams
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Graham Spicer
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| | - Gemma Bale
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Electrical Division, Department of Engineering, Cambridge, United Kingdom, United Kingdom
| | - Sarah E Bohndiek
- University of Cambridge, Department of Physics, Cavendish Laboratory, Cambridge, United Kingdom, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom, United Kingdom
| |
Collapse
|
10
|
Wang J, Chu Y, Wang B, Jiang T. A Narrative Review of Ultrasound Technologies for the Prediction of Neoadjuvant Chemotherapy Response in Breast Cancer. Cancer Manag Res 2021; 13:7885-7895. [PMID: 34703310 PMCID: PMC8523361 DOI: 10.2147/cmar.s331665] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 09/29/2021] [Indexed: 12/21/2022] Open
Abstract
The incidence and mortality rate of breast cancer (BC) in women currently ranks first worldwide, and neoadjuvant chemotherapy (NAC) is widely used in patients with BC. A variety of imaging assessment methods have been used to predict and evaluate the response to NAC. Ultrasound (US) has many advantages, such as being inexpensive and offering a convenient modality for follow-up detection without radiation emission. Although conventional grayscale US is typically used to predict the response to NAC, this approach is limited in its ability to distinguish viable tumor tissue from fibrotic scar tissue. Contrast-enhanced ultrasound (CEUS) combined with a time-intensity curve (TIC) not only provides information on blood perfusion but also reveals a variety of quantitative parameters; elastography has the potential capacity to predict NAC efficiency by evaluating tissue stiffness. Both CEUS and elastography can greatly improve the accuracy of predicting NAC responses. Other US techniques, including three-dimensional (3D) techniques, quantitative ultrasound (QUS) and US-guided near-infrared (NIR) diffuse optical tomography (DOT) systems, also have advantages in assessing NAC response. This paper reviews the different US technologies used for predicting NAC response in BC patients based on the previous literature.
Collapse
Affiliation(s)
- Jing Wang
- Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, 310003, People's Republic of China
| | - Yanhua Chu
- Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, 310003, People's Republic of China
| | - Baohua Wang
- Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, 310003, People's Republic of China
| | - Tianan Jiang
- Department of Ultrasound, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, 310003, People's Republic of China
| |
Collapse
|
11
|
Yun S, Kim Y, Kim H, Lee S, Jeong U, Lee H, Choi YW, Cho S. Three-compartment-breast (3CB) prior-guided diffuse optical tomography based on dual-energy digital breast tomosynthesis (DBT). BIOMEDICAL OPTICS EXPRESS 2021; 12:4837-4851. [PMID: 34513228 PMCID: PMC8407844 DOI: 10.1364/boe.431244] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 07/01/2021] [Accepted: 07/03/2021] [Indexed: 05/18/2023]
Abstract
Diffuse optical tomography (DOT) is a non-invasive functional imaging modality that uses near-infrared (NIR) light to measure the oxygenation state and the concentration of hemoglobin. By complementarily using DOT with other anatomical imaging modalities, physicians can diagnose more accurately through additional functional image information. In breast imaging, diagnosis of dense breasts is often challenging because the bulky fibrous tissues may hinder the correct tumor characterization. In this work, we proposed a three-compartment-breast (3CB) decomposition-based prior-guided optical tomography for enhancing DOT image quality. We conjectured that the 3CB prior would lead to improvement of the spatial resolution and also of the contrast of the reconstructed tumor image, particularly for the dense breasts. We conducted a Monte-Carlo simulation to acquire dual-energy X-ray projections of a realistic 3D numerical breast phantom and performed digital breast tomosynthesis (DBT) for setting up a 3CB model. The 3CB prior was then used as a structural guide in DOT image reconstruction. The proposed method resulted in the higher spatial resolution of the recovered tumor even when the tumor is surrounded by the fibroglandular tissues compared with the typical two-composition-prior method or the standard Tikhonov regularization method.
Collapse
Affiliation(s)
- Sungho Yun
- Department of Nuclear and Quantum Engineering, KAIST, Daejeon 34141, Republic of Korea
| | - Yejin Kim
- Department of Nuclear and Quantum Engineering, KAIST, Daejeon 34141, Republic of Korea
| | - Hyeongseok Kim
- Department of Nuclear and Quantum Engineering, KAIST, Daejeon 34141, Republic of Korea
- KAIST Institute for Artificial Intelligence, KAIST, Daejeon 34141, Republic of Korea
| | - Seoyoung Lee
- Department of Nuclear and Quantum Engineering, KAIST, Daejeon 34141, Republic of Korea
| | - Uijin Jeong
- Department of Nuclear and Quantum Engineering, KAIST, Daejeon 34141, Republic of Korea
| | - Hoyeon Lee
- Department of Radiation and Oncology, MGH, Boston 02114, USA
| | - Young-wook Choi
- Korea Electrotechnology Research Institute, Ansan 15588, Republic of Korea
| | - Seungryong Cho
- Department of Nuclear and Quantum Engineering, KAIST, Daejeon 34141, Republic of Korea
- KAIST Institute for Artificial Intelligence, KAIST, Daejeon 34141, Republic of Korea
- KAIST Institutes for ITC and HST, KAIST, Daejeon 34141, Republic of Korea
| |
Collapse
|
12
|
Cortese L, Lo Presti G, Pagliazzi M, Contini D, Dalla Mora A, Dehghani H, Ferri F, Fischer JB, Giovannella M, Martelli F, Weigel UM, Wojtkiewicz S, Zanoletti M, Durduran T. Recipes for diffuse correlation spectroscopy instrument design using commonly utilized hardware based on targets for signal-to-noise ratio and precision. BIOMEDICAL OPTICS EXPRESS 2021; 12:3265-3281. [PMID: 34221659 PMCID: PMC8221932 DOI: 10.1364/boe.423071] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 04/18/2021] [Accepted: 05/04/2021] [Indexed: 05/09/2023]
Abstract
Over the recent years, a typical implementation of diffuse correlation spectroscopy (DCS) instrumentation has been adapted widely. However, there are no detailed and accepted recipes for designing such instrumentation to meet pre-defined signal-to-noise ratio (SNR) and precision targets. These require specific attention due to the subtleties of the DCS signals. Here, DCS experiments have been performed using liquid tissue simulating phantoms to study the effect of the detected photon count-rate, the number of parallel detection channels and the measurement duration on the precision and SNR to suggest scaling relations to be utilized for device design.
Collapse
Affiliation(s)
- Lorenzo Cortese
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- These authors equally contributed to this work. Authors are listed in alphabetical order except for the first three and the last
| | - Giuseppe Lo Presti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- These authors equally contributed to this work. Authors are listed in alphabetical order except for the first three and the last
| | - Marco Pagliazzi
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Davide Contini
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | | | - Hamid Dehghani
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, UK
| | - Fabio Ferri
- Università degli Studi dell’Insubria, Dipartimento di Scienza e Alta Tecnologia and To. Sca. Lab., 22100 Como, Italy
| | - Jonas B. Fischer
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- HemoPhotonics S.L., 08860 Castelldefels (Barcelona), Spain
| | - Martina Giovannella
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
| | - Fabrizio Martelli
- Università degli Studi di Firenze, Dipartimento di Fisica, 50100 Firenze, Italy
| | - Udo M. Weigel
- HemoPhotonics S.L., 08860 Castelldefels (Barcelona), Spain
| | - Stanislaw Wojtkiewicz
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, UK
| | - Marta Zanoletti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08015 Barcelona, Spain
| |
Collapse
|
13
|
Cortese L, Lo Presti G, Zanoletti M, Aranda G, Buttafava M, Contini D, Dalla Mora A, Dehghani H, Di Sieno L, de Fraguier S, Hanzu FA, Mora Porta M, Nguyen-Dinh A, Renna M, Rosinski B, Squarcia M, Tosi A, Weigel UM, Wojtkiewicz S, Durduran T. The LUCA device: a multi-modal platform combining diffuse optics and ultrasound imaging for thyroid cancer screening. BIOMEDICAL OPTICS EXPRESS 2021; 12:3392-3409. [PMID: 34221667 PMCID: PMC8221941 DOI: 10.1364/boe.416561] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 05/07/2021] [Accepted: 05/07/2021] [Indexed: 05/07/2023]
Abstract
We present the LUCA device, a multi-modal platform combining eight-wavelength near infrared time resolved spectroscopy, sixteen-channel diffuse correlation spectroscopy and a clinical ultrasound in a single device. By simultaneously measuring the tissue hemodynamics and performing ultrasound imaging, this platform aims to tackle the low specificity and sensitivity of the current thyroid cancer diagnosis techniques, improving the screening of thyroid nodules. Here, we show a detailed description of the device, components and modules. Furthermore, we show the device tests performed through well established protocols for phantom validation, and the performance assessment for in vivo. The characterization tests demonstrate that LUCA device is capable of performing high quality measurements, with a precision in determining in vivo tissue optical and dynamic properties of better than 3%, and a reproducibility of better than 10% after ultrasound-guided probe repositioning, even with low photon count-rates, making it suitable for a wide variety of clinical applications.
Collapse
Affiliation(s)
- Lorenzo Cortese
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- These authors equally contributed to this work. Authors are listed in alphabetical order except for the first three and the last
| | - Giuseppe Lo Presti
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- These authors equally contributed to this work. Authors are listed in alphabetical order except for the first three and the last
| | - Marta Zanoletti
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | - Gloria Aranda
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
| | - Mauro Buttafava
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, 20133 Milano, Italy
| | - Davide Contini
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | | | - Hamid Dehghani
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, UK
| | - Laura Di Sieno
- Politecnico di Milano, Dipartimento di Fisica, 20133 Milano, Italy
| | | | - Felicia A. Hanzu
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
- Endocrinology and Nutrition Department, Hospital Clínic of Barcelona, Barcelona, Spain
- Centro de Investigación Biomèdica en Red Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Spain
| | - Mireia Mora Porta
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
- Endocrinology and Nutrition Department, Hospital Clínic of Barcelona, Barcelona, Spain
- Centro de Investigación Biomèdica en Red Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Spain
| | | | - Marco Renna
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, 20133 Milano, Italy
- Athinoula A. Martinos Center for Biomedical Imaging, MGH, Harvard Medical School, Charlestown, MA 02129, USA
| | | | - Mattia Squarcia
- IDIBAPS, Fundació Clínic per la Recerca Biomèdica, Barcelona, Spain
- Neuroradiology Department, Hospital Clínic of Barcelona, Barcelona, Spain
| | - Alberto Tosi
- Politecnico di Milano, Dipartimento di Elettronica Informazione e Bioingegneria, 20133 Milano, Italy
| | - Udo M. Weigel
- HemoPhotonics S.L., 08860 Castelldefels (Barcelona), Spain
| | - Stanislaw Wojtkiewicz
- University of Birmingham, School of Computer Science, Edgbaston, Birmingham, B15 2TT, UK
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08015 Barcelona, Spain
| |
Collapse
|
14
|
Robbins CM, Tabassum S, Baumhauer MF, Yang J, Antaki JF, Kainerstorfer JM. Two-layer spatial frequency domain imaging of compression-induced hemodynamic changes in breast tissue. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:056005. [PMCID: PMC8145994 DOI: 10.1117/1.jbo.26.5.056005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 05/04/2021] [Indexed: 06/15/2023]
Abstract
Significance: Longitudinal tracking of hemodynamic changes in the breast has shown potential for neoadjuvant chemotherapy (NAC) outcome prediction. Spatial frequency domain imaging (SFDI) could be suitable for frequent monitoring of shallow breast tumors, but strong sensitivity to superficial absorbers presents a challenge. Aim: We investigated the efficacy of a two-layer SFDI inverse model that accounts for varying melanin concentration in the skin to improve discrimination of optical properties of deep tissue of the breast. Approach: Hemodynamic changes in response to localized breast compression were measured in 13 healthy volunteers using a handheld SFDI device. Epidermis optical thickness was determined based on spectral fitting of the model output and used to calculate subcutaneous optical properties. Results: Optical properties from a homogeneous model yielded physiologically unreasonable absorption and scattering coefficients for highly pigmented volunteers. The two-layer model compensated for the effect of melanin and yielded properties in the expected range for healthy breast. Extracted epidermal optical thickness was higher for higher Fitzpatrick types. Compression induced a decrease in total hemoglobin consistent with tissue blanching. Conclusions: The handheld SFDI device and two-layer model show potential for imaging hemodynamic responses that potentially could help predict efficacy of NAC in patients of varying skin tones.
Collapse
Affiliation(s)
- Constance M. Robbins
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - Syeda Tabassum
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - Molly F. Baumhauer
- Carnegie Mellon University, Department of Physics, Pittsburgh, Pennsylvania, United States
| | - Jason Yang
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - James F. Antaki
- Cornell University, School of Biomedical Engineering, Ithaca, New York, United States
| | - Jana M. Kainerstorfer
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
- Carnegie Mellon University, Neuroscience Institute, Pittsburgh, Pennsylvania, United States
| |
Collapse
|
15
|
Maffeis G, Ferocino E, Mora AD, Pifferi A, Cubeddu R, Taroni P. In vivo test-driven upgrade of a time domain multi-wavelength optical mammograph. BIOMEDICAL OPTICS EXPRESS 2021; 12:1105-1122. [PMID: 33680561 PMCID: PMC7901327 DOI: 10.1364/boe.412210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 01/06/2021] [Accepted: 01/19/2021] [Indexed: 05/23/2023]
Abstract
A recent upgrade of the time domain multi-wavelength optical mammograph developed by Politecnico di Milano achieved good performance in laboratory tests [Biomed. Opt. Express9, 755 (2018).10.1364/BOE.9.000755]. However, it proved unsatisfactory when in vivo measurements were finally performed. That led to a further upgrade, including the replacement of the time-to-digital converter with a new model, and the related set-up changes. The new instrument version offers improved laboratory performance (as assessed through established protocols: BIP and MEDPHOT) and good in vivo performance (extension of the scanned breast area, repeatability, consistency of estimated tissue composition with physiology). Besides introducing the new set-up and detailing its laboratory and in vivo performance, we highlight the importance of systematic in vivo testing before entering clinical trials.
Collapse
Affiliation(s)
- Giulia Maffeis
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Edoardo Ferocino
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Alberto Dalla Mora
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Antonio Pifferi
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
- CNR-Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Rinaldo Cubeddu
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Paola Taroni
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
- CNR-Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| |
Collapse
|
16
|
Effects of neoadjuvant chemotherapy on the contralateral non-tumor-bearing breast assessed by diffuse optical tomography. Breast Cancer Res 2021; 23:16. [PMID: 33517909 PMCID: PMC7849076 DOI: 10.1186/s13058-021-01396-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Accepted: 01/20/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The purpose of this study is to evaluate whether the changes in optically derived parameters acquired with a diffuse optical tomography breast imager system (DOTBIS) in the contralateral non-tumor-bearing breast in patients administered neoadjuvant chemotherapy (NAC) for breast cancer are associated with pathologic complete response (pCR). METHODS In this retrospective evaluation of 105 patients with stage II-III breast cancer, oxy-hemoglobin (ctO2Hb) from the contralateral non-tumor-bearing breast was collected and analyzed at different time points during NAC. The earliest monitoring imaging time point was after 2-3 weeks receiving taxane. Longitudinal data were analyzed using linear mixed-effects modeling to evaluate the contralateral breast ctO2Hb changes across chemotherapy when corrected for pCR status, age, and BMI. RESULTS Patients who achieved pCR to NAC had an overall decrease of 3.88 μM for ctO2Hb (95% CI, 1.39 to 6.37 μM), p = .004, after 2-3 weeks. On the other hand, non-pCR subjects had a non-significant mean reduction of 0.14 μM (95% CI, - 1.30 to 1.58 μM), p > .05. Mixed-effect model results indicated a statistically significant negative relationship of ctO2Hb levels with BMI and age. CONCLUSIONS This study demonstrates that the contralateral normal breast tissue assessed by DOTBIS is modifiable after NAC, with changes associated with pCR after only 2-3 weeks of chemotherapy.
Collapse
|
17
|
Hayashi M, Yoshizawa N, Ueda Y, Mimura T, Ohmae E, Yoshimoto K, Wada H, Nasu H, Ogura H, Sakahara H. Effect of Source-Detector Distance on the Measurement of Hemoglobin Using Near-Infrared Spectroscopy in Breast Cancer. Technol Cancer Res Treat 2019; 18:1533033819830411. [PMID: 30764728 PMCID: PMC6378435 DOI: 10.1177/1533033819830411] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
We measured total hemoglobin concentrations in breast tumors by near-infrared time-resolved spectroscopy. Muscles interfere with measurement when the probe is close to the chest wall. Since the target area of measurement depends on the distance between the light source and probe detector, we inferred that this issue could be solved by reducing the source-detector distance. The purpose of this study was to examine the effects of the source-detector distance on the measurement of total hemoglobin concentration in the breast. We examined 26 patients with breast tumors. Total hemoglobin concentration was measured in tumors and the contralateral normal breasts at source-detector distances of 20 and 30 mm. The difference in total hemoglobin concentration between each tumor and the contralateral breast was calculated. The normal breast total hemoglobin concentration was significantly smaller for the source-detector distance of 20 mm than for the source-detector distance of 30 mm. Differences in source-detector distance did not significantly affect tumor total hemoglobin. The difference in total hemoglobin concentration between the tumor and the contralateral breast obtained at the source-detector distance of 20 mm was significantly higher than that obtained at the source-detector distance of 30 mm. From these results, we considered that measurement with a source-detector distance of 20 mm is less affected by the chest wall than with a source-detector distance of 30 mm and that the difference in total hemoglobin concentration between the tumor and the contralateral breast at a source-detector distance of 20 mm can better reflect the net total hemoglobin concentrations of the breast tumors. In conclusion, using a probe with a source-detector distance of 20 mm can more accurately evaluate the total hemoglobin concentration in breast tumors.
Collapse
Affiliation(s)
- Maho Hayashi
- 1 Department of Diagnostic Radiology & Nuclear Medicine, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Nobuko Yoshizawa
- 1 Department of Diagnostic Radiology & Nuclear Medicine, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Yukio Ueda
- 1 Department of Diagnostic Radiology & Nuclear Medicine, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Tetsuya Mimura
- 2 Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Etsuko Ohmae
- 2 Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Kenji Yoshimoto
- 2 Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Hiroko Wada
- 2 Central Research Laboratory, Hamamatsu Photonics K.K., Hamamatsu, Shizuoka, Japan
| | - Hatusko Nasu
- 1 Department of Diagnostic Radiology & Nuclear Medicine, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Hiroyuki Ogura
- 3 First Department of Surgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| | - Harumi Sakahara
- 1 Department of Diagnostic Radiology & Nuclear Medicine, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
| |
Collapse
|
18
|
Mireles M, Morales-Dalmau J, Johansson JD, Vidal-Rosas EE, Vilches C, Martínez-Lozano M, Sanz V, de Miguel I, Casanovas O, Quidant R, Durduran T. Non-invasive and quantitative in vivo monitoring of gold nanoparticle concentration and tissue hemodynamics by hybrid optical spectroscopies. NANOSCALE 2019; 11:5595-5606. [PMID: 30860518 DOI: 10.1039/c8nr08790c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Owing to their unique combination of chemical and physical properties, inorganic nanoparticles show a great deal of potential as suitable agents for early diagnostics and less invasive therapies. Yet, their translation to the clinic has been hindered, in part, by the lack of non-invasive methods to quantify their concentration in vivo while also assessing their effect on the tissue physiology. In this work, we demonstrate that diffuse optical techniques, employing near-infrared light, have the potential to address this need in the case of gold nanoparticles which support localized surface plasmons. An orthoxenograft mouse model of clear cell renal cell carcinoma was non-invasively assessed by diffuse reflectance and correlation spectroscopies before and over several days following a single intravenous tail vein injection of polyethylene glycol-coated gold nanorods (AuNRs-PEG). Our platform enables to resolve the kinetics of the AuNR-PEG uptake by the tumor in quantitative agreement with ex vivo inductively coupled plasma mass spectroscopy. Furthermore, it allows for the simultaneous monitoring of local tissue hemodynamics, enabling us to conclude that AuNRs-PEG do not significantly alter the animal physiology. We note that the penetration depth of this current probe was a few millimeters but can readily be extended to centimeters, hence gaining clinical relevance. This study and the methodology presented here complement the nanomedicine toolbox by providing a flexible platform, extendable to other absorbing agents that can potentially be translated to human trials.
Collapse
Affiliation(s)
- Miguel Mireles
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Barcelona, Spain.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Han S, Proctor AR, Ren J, Benoit DSW, Choe R. Temporal blood flow changes measured by diffuse correlation tomography predict murine femoral graft healing. PLoS One 2018; 13:e0197031. [PMID: 29813078 PMCID: PMC5973582 DOI: 10.1371/journal.pone.0197031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 04/25/2018] [Indexed: 12/18/2022] Open
Abstract
Blood flow changes during bone graft healing have the potential to provide important information about graft success, as the nutrients, oxygen, circulating cells and growth factors essential for integration are delivered by blood. However, longitudinal monitoring of blood flow changes during graft healing has been a challenge due to limitations in current techniques. To this end, non-invasive diffuse correlation tomography (DCT) was investigated to enable longitudinal monitoring of three-dimensional blood flow changes in deep tissue. Specific to this study, longitudinal blood flow changes were utilized to predict healing outcomes of common interventions for massive bone defects using a common mouse femoral defect model. Weekly blood flow changes were non-invasively measured using a diffuse correlation tomography system for 9 weeks in three types of grafts: autografts (N = 7), allografts (N = 6) and tissue-engineered allografts (N = 6). Healing outcomes were quantified using an established torsion testing method 9 weeks after transplantation. Analysis of the spatial and temporal blood flow reveals that major differences among the three groups were captured in weeks 1-5 after graft transplantation. A multivariate model to predict maximum torque by relative blood flow changes over 5 weeks after graft transplantation was built using partial least squares regression. The results reveal lower bone strength correlates with greater cumulative blood flow over an extended period of time (i.e., 1-5 weeks). The current research demonstrates that DCT-measured blood flow changes after graft transplantation can be utilized to predict long-term healing outcomes in a mouse femoral graft model.
Collapse
Affiliation(s)
- Songfeng Han
- Institute of Optics, University of Rochester, Rochester, NY, United States of America
| | - Ashley R. Proctor
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States of America
| | - Jingxuan Ren
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States of America
| | - Danielle S. W. Benoit
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States of America
- Department of Orthopaedics and Center for Musculoskeletal Research, University of Rochester Medical Center, Rochester, NY, United States of America
- Department of Chemical Engineering, University of Rochester, Rochester, NY, United States of America
- Department of Biomedical Genetics, University of Rochester Medical Center, Rochester, NY, United States of America
| | - Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, NY, United States of America
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY, United States of America
- * E-mail:
| |
Collapse
|
20
|
Lee S, Kim JG. Breast tumor hemodynamic response during a breath-hold as a biomarker to predict chemotherapeutic efficacy: preclinical study. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-5. [PMID: 29706036 DOI: 10.1117/1.jbo.23.4.048001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 04/13/2018] [Indexed: 06/08/2023]
Abstract
Continuous wave diffuse optical tomographic/spectroscopic system does not provide absolute concentrations of chromophores in tissue and monitor only the changes of chromophore concentration. Therefore, it requires a perturbation of physiological signals, such as blood flow and oxygenation. In that sense, a few groups reported that monitoring a relative hemodynamic change during a breast tissue compression or a breath-hold to a patient can provide good contrast between tumor and nontumor. However, no longitudinal study reports the utilization of a breath-hold to predict tumor response during chemotherapy. A continuous wave near-infrared spectroscopy was employed to monitor hemodynamics in rat breast tumor during a hyperoxic to normoxic inhalational gas intervention to mimic a breath-hold during tumor growth and chemotherapy. The reduced oxyhemoglobin concentration during inhalational gas intervention correlated well with tumor growth, and it responded one day earlier than the change of tumor volume after chemotherapy. In conclusion, monitoring tumor hemodynamics during a breath-hold may serve as a biomarker to predict chemotherapeutic efficacy of tumor.
Collapse
Affiliation(s)
- Songhyun Lee
- Gwangju Institute of Science and Technology, Department of Biomedical Science and Engineering, Gwang, Republic of Korea
| | - Jae Gwan Kim
- Gwangju Institute of Science and Technology, Department of Biomedical Science and Engineering, Gwang, Republic of Korea
- Gwangju Institute of Science and Technology, School of Electrical Engineering and Computer Science,, Republic of Korea
| |
Collapse
|
21
|
Deng B, Lundqvist M, Fang Q, Carp SA. Impact of errors in experimental parameters on reconstructed breast images using diffuse optical tomography. BIOMEDICAL OPTICS EXPRESS 2018; 9:1130-1150. [PMID: 29541508 PMCID: PMC5846518 DOI: 10.1364/boe.9.001130] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 12/18/2017] [Accepted: 12/30/2017] [Indexed: 05/18/2023]
Abstract
Near-infrared diffuse optical tomography (NIR-DOT) is an emerging technology that offers hemoglobin based, functional imaging tumor biomarkers for breast cancer management. The most promising clinical translation opportunities are in the differential diagnosis of malignant vs. benign lesions, and in early response assessment and guidance for neoadjuvant chemotherapy. Accurate quantification of the tissue oxy- and deoxy-hemoglobin concentration across the field of view, as well as repeatability during longitudinal imaging in the context of therapy guidance, are essential for the successful translation of NIR-DOT to clinical practice. The ill-posed and ill-condition nature of the DOT inverse problem makes this technique particularly susceptible to model errors that may occur, for example, when the experimental conditions do not fully match the assumptions built into the image reconstruction process. To evaluate the susceptibility of DOT images to experimental errors that might be encountered in practice for a parallel-plate NIR-DOT system, we simulated 7 different types of errors, each with a range of magnitudes. We generated simulated data by using digital breast phantoms derived from five actual mammograms of healthy female volunteers, to which we added a 1-cm tumor. After applying each of the experimental error types and magnitudes to the simulated measurements, we reconstructed optical images with and without structural prior guidance and assessed the overall error in the total hemoglobin concentrations (HbT) and in the HbT contrast between the lesion and surrounding area vs. the best-case scenarios. It is found that slight in-plane probe misalignment and plate rotation did not result in large quantification errors. However, any out-of-plane probe tilting could result in significant deterioration in lesion contrast. Among the error types investigated in this work, optical images were the least likely to be impacted by breast shape inaccuracies but suffered the largest deterioration due to cross-talk between signal channels. However, errors in optical images could be effectively controlled when experimental parameters were properly estimated during data acquisition and accounted for in the image processing procedure. Finally, optical images recovered using structural priors were, in general, less susceptible to experimental errors; however, lesion contrasts were more sensitive to errors when tumor locations were used as a priori info. Findings in this simulation study can provide guidelines for system design and operation in optical breast imaging studies.
Collapse
Affiliation(s)
- Bin Deng
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA 02129, USA
| | - Mats Lundqvist
- Philips Healthcare, Torshamnsgatan 30A, 164 40 Kista, Sweden
| | - Qianqian Fang
- Department of Bioengineering, Northeastern University, Boston, MA 02115, USA
| | - Stefan A. Carp
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA 02129, USA
| |
Collapse
|
22
|
Ferocino E, Martinenghi E, Dalla Mora A, Pifferi A, Cubeddu R, Taroni P. High throughput detection chain for time domain optical mammography. BIOMEDICAL OPTICS EXPRESS 2018; 9:755-770. [PMID: 29552410 PMCID: PMC5854076 DOI: 10.1364/boe.9.000755] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 12/16/2017] [Accepted: 01/09/2018] [Indexed: 05/04/2023]
Abstract
A novel detection chain, based on 8 Silicon Photomultipliers (forming a wide-area custom-made detection probe) and on a time-to-digital converter, was developed to improve the signal level in multi-wavelength (635-1060 nm) time domain optical mammography. The performances of individual components and of the overall chain were assessed using established protocols (BIP and MEDPHOT). The photon detection efficiency was improved by up to 3 orders of magnitude, and the maximum count rate level was increased by a factor of 10 when compared to the previous system, based on photomultiplier tubes and conventional time-correlated single-photon counting boards. In the estimate of optical parameters, the novel detection chain provides performances comparable to the previous system, widely validated in clinics, but with higher signal level, higher robustness, and at a lower price per channel, thus targeting important requirements for clinical applications.
Collapse
Affiliation(s)
- Edoardo Ferocino
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Edoardo Martinenghi
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Alberto Dalla Mora
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Antonio Pifferi
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
- CNR-Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Rinaldo Cubeddu
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| | - Paola Taroni
- Politecnico di Milano, Department of Physics, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
- CNR-Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy
| |
Collapse
|
23
|
Lee S, Jeong H, Seong M, Kim JG. Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:121603. [PMID: 28698890 DOI: 10.1117/1.jbo.22.12.121603] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Accepted: 05/31/2017] [Indexed: 05/22/2023]
Abstract
Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor response from chemotherapy by monitoring tumor volume changes. We used near-infrared spectroscopy (NIRS) to predict breast cancer treatment efficacy earlier than tumor volume changes by monitoring tumor vascular reactivity during inhalational gas interventions. The results show that the amplitude of oxy-hemoglobin changes (vascular reactivity) during hyperoxic gas inhalation is well correlated with tumor growth and responded one day earlier than tumor volume changes after chemotherapy. These results may imply that NIRS with respiratory challenges can be useful in early detection of tumor and in the prediction of tumor response to chemotherapy.
Collapse
Affiliation(s)
- Songhyun Lee
- Gwangju Institute of Science and Technology, Department of Biomedical Science and Engineering, Gwangju, Republic of Korea
| | - Hyeryun Jeong
- Gwangju Institute of Science and Technology, Department of Biomedical Science and Engineering, Gwangju, Republic of Korea
| | - Myeongsu Seong
- Gwangju Institute of Science and Technology, Department of Biomedical Science and Engineering, Gwangju, Republic of Korea
| | - Jae Gwan Kim
- Gwangju Institute of Science and Technology, Department of Biomedical Science and Engineering, Gwangju, Republic of KoreabGwangju Institute of Science and Technology, School of Electrical Engineering and Computer Science, Gwangju, Republic of Korea
| |
Collapse
|
24
|
Robbins CM, Raghavan G, Antaki JF, Kainerstorfer JM. Feasibility of spatial frequency-domain imaging for monitoring palpable breast lesions. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-9. [PMID: 28831792 PMCID: PMC5997013 DOI: 10.1117/1.jbo.22.12.121605] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Accepted: 07/27/2017] [Indexed: 05/04/2023]
Abstract
In breast cancer diagnosis and therapy monitoring, there is a need for frequent, noninvasive disease progression evaluation. Breast tumors differ from healthy tissue in mechanical stiffness as well as optical properties, which allows optical methods to detect and monitor breast lesions noninvasively. Spatial frequency-domain imaging (SFDI) is a reflectance-based diffuse optical method that can yield two-dimensional images of absolute optical properties of tissue with an inexpensive and portable system, although depth penetration is limited. Since the absorption coefficient of breast tissue is relatively low and the tissue is quite flexible, there is an opportunity for compression of tissue to bring stiff, palpable breast lesions within the detection range of SFDI. Sixteen breast tissue-mimicking phantoms were fabricated containing stiffer, more highly absorbing tumor-mimicking inclusions of varying absorption contrast and depth. These phantoms were imaged with an SFDI system at five levels of compression. An increase in absorption contrast was observed with compression, and reliable detection of each inclusion was achieved when compression was sufficient to bring the inclusion center within ∼12 mm of the phantom surface. At highest compression level, contrasts achieved with this system were comparable to those measured with single source-detector near-infrared spectroscopy.
Collapse
Affiliation(s)
- Constance M. Robbins
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - Guruprasad Raghavan
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - James F. Antaki
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
| | - Jana M. Kainerstorfer
- Carnegie Mellon University, Department of Biomedical Engineering, Pittsburgh, Pennsylvania, United States
- Address all correspondence to: Jana M. Kainerstorfer, E-mail:
| |
Collapse
|
25
|
Farzam P, Johansson J, Mireles M, Jiménez-Valerio G, Martínez-Lozano M, Choe R, Casanovas O, Durduran T. Pre-clinical longitudinal monitoring of hemodynamic response to anti-vascular chemotherapy by hybrid diffuse optics. BIOMEDICAL OPTICS EXPRESS 2017; 8:2563-2582. [PMID: 28663891 PMCID: PMC5480498 DOI: 10.1364/boe.8.002563] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 03/20/2017] [Accepted: 03/30/2017] [Indexed: 05/20/2023]
Abstract
The longitudinal effect of an anti-vascular endothelial growth factor receptor 2 (VEGFR-2) antibody (DC 101) therapy on a xenografted renal cell carcinoma (RCC) mouse model was monitored using hybrid diffuse optics. Two groups of immunosuppressed male nude mice (seven treated, seven controls) were measured. Tumor microvascular blood flow, total hemoglobin concentration and blood oxygenation were investigated as potential biomarkers for the monitoring of the therapy effect twice a week and were related to the final treatment outcome. These hemodynamic biomarkers have shown a clear differentiation between two groups by day four. Moreover, we have observed that pre-treatment values and early changes in hemodynamics are highly correlated with the therapeutic outcome demonstrating the potential of diffuse optics to predict the therapy response at an early time point.
Collapse
Affiliation(s)
- Parisa Farzam
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona),
Spain
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129,
USA
| | - Johannes Johansson
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona),
Spain
- Department of Biomedical Engineering, Linköping University, 58185 Linköping,
Sweden
| | - Miguel Mireles
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona),
Spain
| | - Gabriela Jiménez-Valerio
- Program Against Cancer Therapeutic Resistance (ProCURE), Catalan Institute of Oncology, Bellvitge Biomedical Research Institute – IDIBELL, 08908, L’Hospitalet de Llobregat (Barcelona),
Spain
| | - Mar Martínez-Lozano
- Program Against Cancer Therapeutic Resistance (ProCURE), Catalan Institute of Oncology, Bellvitge Biomedical Research Institute – IDIBELL, 08908, L’Hospitalet de Llobregat (Barcelona),
Spain
| | - Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Oriol Casanovas
- Program Against Cancer Therapeutic Resistance (ProCURE), Catalan Institute of Oncology, Bellvitge Biomedical Research Institute – IDIBELL, 08908, L’Hospitalet de Llobregat (Barcelona),
Spain
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Sciences and Technology, 08860, Castelldefels (Barcelona),
Spain
- Instituciò Catalana de Recerca i Estudis Avançats (ICREA), 08015, Barcelona,
Spain
| |
Collapse
|
26
|
Cochran JM, Chung SH, Leproux A, Baker WB, Busch DR, DeMichele AM, Tchou J, Tromberg BJ, Yodh AG. Longitudinal optical monitoring of blood flow in breast tumors during neoadjuvant chemotherapy. Phys Med Biol 2017; 62:4637-4653. [PMID: 28402286 DOI: 10.1088/1361-6560/aa6cef] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
We measure tissue blood flow markers in breast tumors during neoadjuvant chemotherapy and investigate their correlation to pathologic complete response in a pilot longitudinal patient study (n = 4). Tumor blood flow is quantified optically by diffuse correlation spectroscopy (DCS), and tissue optical properties, blood oxygen saturation, and total hemoglobin concentration are derived from concurrent diffuse optical spectroscopic imaging (DOSI). The study represents the first longitudinal DCS measurement of neoadjuvant chemotherapy in humans over the entire course of treatment; it therefore offers a first correlation between DCS flow indices and pathologic complete response. The use of absolute optical properties measured by DOSI facilitates significant improvement of DCS blood flow calculation, which typically assumes optical properties based on literature values. Additionally, the combination of the DCS blood flow index and the tissue oxygen saturation from DOSI permits investigation of tissue oxygen metabolism. Pilot results from four patients suggest that lower blood flow in the lesion-bearing breast is correlated with pathologic complete response. Both absolute lesion blood flow and lesion flow relative to the contralateral breast exhibit potential for characterization of pathological response. This initial demonstration of the combined optical approach for chemotherapy monitoring provides incentive for more comprehensive studies in the future and can help power those investigations.
Collapse
Affiliation(s)
- J M Cochran
- Department of Physics and Astronomy, University of Pennsylvania, 209 S 33rd St, Philadelphia, PA 19104, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Ban HY, Schweiger M, Kavuri VC, Cochran JM, Xie L, Busch DR, Katrašnik J, Pathak S, Chung SH, Lee K, Choe R, Czerniecki BJ, Arridge SR, Yodh AG. Heterodyne frequency-domain multispectral diffuse optical tomography of breast cancer in the parallel-plane transmission geometry. Med Phys 2017; 43:4383. [PMID: 27370153 DOI: 10.1118/1.4953830] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
PURPOSE The authors introduce a state-of-the-art all-optical clinical diffuse optical tomography (DOT) imaging instrument which collects spatially dense, multispectral, frequency-domain breast data in the parallel-plate geometry. METHODS The instrument utilizes a CCD-based heterodyne detection scheme that permits massively parallel detection of diffuse photon density wave amplitude and phase for a large number of source-detector pairs (10(6)). The stand-alone clinical DOT instrument thus offers high spatial resolution with reduced crosstalk between absorption and scattering. Other novel features include a fringe profilometry system for breast boundary segmentation, real-time data normalization, and a patient bed design which permits both axial and sagittal breast measurements. RESULTS The authors validated the instrument using tissue simulating phantoms with two different chromophore-containing targets and one scattering target. The authors also demonstrated the instrument in a case study breast cancer patient; the reconstructed 3D image of endogenous chromophores and scattering gave tumor localization in agreement with MRI. CONCLUSIONS Imaging with a novel parallel-plate DOT breast imager that employs highly parallel, high-resolution CCD detection in the frequency-domain was demonstrated.
Collapse
Affiliation(s)
- H Y Ban
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - M Schweiger
- Department of Computer Science, University College London, London WC1E 7JE, United Kingdom
| | - V C Kavuri
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - J M Cochran
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - L Xie
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - D R Busch
- Division of Neurology, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania 19104
| | - J Katrašnik
- Faculty of Electrical Engineering, University of Ljubljana, Ljubljana 1000, Slovenia
| | - S Pathak
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - S H Chung
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - K Lee
- Daegu Gyeongbuk Institute of Science and Technology, Daegu 711-813, South Korea
| | - R Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14642
| | - B J Czerniecki
- Department of Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - S R Arridge
- Department of Computer Science, University College London, London WC1E 7JE, United Kingdom
| | - A G Yodh
- Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| |
Collapse
|
28
|
Sajjadi AY, Isakoff SJ, Deng B, Singh B, Wanyo CM, Fang Q, Specht MC, Schapira L, Moy B, Bardia A, Boas DA, Carp SA. Normalization of compression-induced hemodynamics in patients responding to neoadjuvant chemotherapy monitored by dynamic tomographic optical breast imaging (DTOBI). BIOMEDICAL OPTICS EXPRESS 2017; 8:555-569. [PMID: 28270967 PMCID: PMC5330555 DOI: 10.1364/boe.8.000555] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Revised: 11/04/2016] [Accepted: 12/05/2016] [Indexed: 05/03/2023]
Abstract
We characterize novel breast cancer imaging biomarkers for monitoring neoadjuvant chemotherapy (NACT) and predicting outcome. Specifically, we recruited 30 patients for a pilot study in which NACT patients were imaged using dynamic tomographic optical breast imaging (DTOBI) to quantify the hemodynamic changes due to partial mammographic compression. DTOBI scans were obtained pre-treatment (referred to as day 0), as well as 7 and 30 days into therapy on female patients undergoing NACT. We present data for the 13 patients who participated in both day 0 and 7 measurements and had evaluable data, of which 7 also returned for day 30 measurements. We acquired optical images over 2 minutes following 4-8 lbs (18-36 N) of compression. The timecourses of tissue-volume averaged total hemoglobin (HbT), as well as hemoglobin oxygen saturation (SO2) in the tumor vs. surrounding tissues were compared. Outcome prediction metrics based on the differential behavior in tumor vs. normal areas for responders (>50% reduction in maximum diameter) vs. non-responders were analyzed for statistical significance. At baseline, all patients exhibit an initial decrease followed by delayed recovery in HbT, and SO2 in the tumor area, in contrast to almost immediate recovery in surrounding tissue. At day 7 and 30, this contrast is maintained in non-responders; however, in responders, the contrast in hemodynamic time-courses between tumor and normal tissue starts decreasing at day 7 and substantially disappears at day 30. At day 30 into NACT, responding tumors demonstrate "normalization" of compression induced hemodynamics vs. surrounding normal tissue whereas non-responding tumors did not. This data suggests that DTOBI imaging biomarkers, which are governed by the interplay between tissue biomechanics and oxygen metabolism, may be suitable for guiding NACT by offering early predictions of treatment outcome.
Collapse
Affiliation(s)
- Amir Y Sajjadi
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA; These authors contributed equally to this work;
| | - Steven J Isakoff
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA; These authors contributed equally to this work;
| | - Bin Deng
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA
| | - Bhawana Singh
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA
| | - Christy M Wanyo
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Qianqian Fang
- Department of Bioengineering, Northeastern University, Boston, MA 0211, USA
| | - Michelle C Specht
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA; Department of Surgery, Harvard Medical School, Boston, MA 02114, USA
| | - Lidia Schapira
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA
| | - Beverly Moy
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA
| | - Aditya Bardia
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA
| | - David A Boas
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA
| | - Stefan A Carp
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA
| |
Collapse
|
29
|
Teng F, Cormier T, Sauer-Budge A, Chaudhury R, Pera V, Istfan R, Chargin D, Brookfield S, Ko NY, Roblyer DM. Wearable near-infrared optical probe for continuous monitoring during breast cancer neoadjuvant chemotherapy infusions. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:14001. [PMID: 28114449 PMCID: PMC5289133 DOI: 10.1117/1.jbo.22.1.014001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Accepted: 12/21/2016] [Indexed: 05/04/2023]
Abstract
We present a new continuous-wave wearable diffuse optical probe aimed at investigating the hemodynamic response of locally advanced breast cancer patients during neoadjuvant chemotherapy infusions. The system consists of a flexible printed circuit board that supports an array of six dual wavelength surface-mount LED and photodiode pairs. The probe is encased in a soft silicone housing that conforms to natural breast shape. Probe performance was evaluated using tissue-simulating phantoms and in vivo normal volunteer measurements. High SNR (71 dB), low source-detector crosstalk ( ? 60 ?? dB ), high measurement precision (0.17%), and good thermal stability (0.22% V rms / ° C ) were achieved in phantom studies. A cuff occlusion experiment was performed on the forearm of a healthy volunteer to demonstrate the ability to track rapid hemodynamic changes. Proof-of-principle normal volunteer measurements were taken to demonstrate the ability to collect continuous in vivo breast measurements. This wearable probe is a first of its kind tool to explore prognostic hemodynamic changes during chemotherapy in breast cancer patients.
Collapse
Affiliation(s)
- Fei Teng
- Boston University, Department of Electrical and Computer Engineering and Photonics Center, 8 Saint Mary’s Street, Boston, Massachusetts 02215, United States
| | - Timothy Cormier
- Boston University, Fraunhofer Center for Manufacturing Innovation, 15 Saint Mary’s Street, Brookline, Massachusetts 02446, United States
| | - Alexis Sauer-Budge
- Boston University, Fraunhofer Center for Manufacturing Innovation, 15 Saint Mary’s Street, Brookline, Massachusetts 02446, United States
| | - Rachita Chaudhury
- Boston University, Department of Biomedical Engineering, 44 Cummington Mall, Boston, Massachusetts 02215, United States
| | - Vivian Pera
- Boston University, Department of Biomedical Engineering, 44 Cummington Mall, Boston, Massachusetts 02215, United States
| | - Raeef Istfan
- Boston University, Department of Biomedical Engineering, 44 Cummington Mall, Boston, Massachusetts 02215, United States
| | - David Chargin
- Boston University, Fraunhofer Center for Manufacturing Innovation, 15 Saint Mary’s Street, Brookline, Massachusetts 02446, United States
| | - Samuel Brookfield
- Boston University, Fraunhofer Center for Manufacturing Innovation, 15 Saint Mary’s Street, Brookline, Massachusetts 02446, United States
| | - Naomi Yu Ko
- Boston Medical Center, Section of Hematology and Oncology, Women’s Health Unit, 801 Massachusetts Avenue, First Floor, Boston, Massachusetts 02118, United States
| | - Darren M. Roblyer
- Boston University, Department of Biomedical Engineering, 44 Cummington Mall, Boston, Massachusetts 02215, United States
- Address all correspondence to: Darren M. Roblyer, E-mail:
| |
Collapse
|
30
|
Ramirez G, Proctor AR, Jung KW, Wu TT, Han S, Adams RR, Ren J, Byun DK, Madden KS, Brown EB, Foster TH, Farzam P, Durduran T, Choe R. Chemotherapeutic drug-specific alteration of microvascular blood flow in murine breast cancer as measured by diffuse correlation spectroscopy. BIOMEDICAL OPTICS EXPRESS 2016; 7:3610-3630. [PMID: 27699124 PMCID: PMC5030036 DOI: 10.1364/boe.7.003610] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 08/16/2016] [Accepted: 08/17/2016] [Indexed: 05/08/2023]
Abstract
The non-invasive, in vivo measurement of microvascular blood flow has the potential to enhance breast cancer therapy monitoring. Here, longitudinal blood flow of 4T1 murine breast cancer (N=125) under chemotherapy was quantified with diffuse correlation spectroscopy based on layer models. Six different treatment regimens involving doxorubicin, cyclophosphamide, and paclitaxel at clinically relevant doses were investigated. Treatments with cyclophosphamide increased blood flow as early as 3 days after administration, whereas paclitaxel induced a transient blood flow decrease at 1 day after administration. Early blood flow changes correlated strongly with the treatment outcome and distinguished treated from untreated mice individually for effective treatments.
Collapse
Affiliation(s)
- Gabriel Ramirez
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Ashley R. Proctor
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Ki Won Jung
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Tong Tong Wu
- Department of Biostatistics and Computational Biology, University of Rochester Medical Center, Rochester, NY 14642,
USA
| | - Songfeng Han
- The Institute of Optics, University of Rochester, Rochester, NY 14627,
USA
| | - Russell R. Adams
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Jingxuan Ren
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Daniel K. Byun
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Kelley S. Madden
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Edward B. Brown
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
| | - Thomas H. Foster
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
- The Institute of Optics, University of Rochester, Rochester, NY 14627,
USA
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY 14642,
USA
| | - Parisa Farzam
- ICFO- Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona),
Spain
| | - Turgut Durduran
- ICFO- Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels (Barcelona),
Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), 08015 Barcelona,
Spain
| | - Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627,
USA
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY 14627,
USA
| |
Collapse
|
31
|
Deán-Ben XL, Fehm TF, Gostic M, Razansky D. Volumetric hand-held optoacoustic angiography as a tool for real-time screening of dense breast. JOURNAL OF BIOPHOTONICS 2016; 9:253-9. [PMID: 25966021 DOI: 10.1002/jbio.201500008] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 03/24/2015] [Accepted: 03/26/2015] [Indexed: 05/19/2023]
Abstract
Existing mammographic screening solutions are generally associated with several major drawbacks, such as exposure to ionizing radiation or insufficient sensitivity in younger populations with radiographically-dense breast. Even when combined with ultrasound or magnetic resonance imaging, X-Ray mammography may still attain unspecific or false positive results. Thus, development of new breast imaging tools represents a timely medical challenge. We report on a new approach to high-resolution functional and anatomical breast angiography using volumetric hand-held optoacoustic tomography, which employs light intensities safe for human use. Experiments in young healthy volunteers with fibroglandular-dominated dense breasts revealed the feasibility of rendering three-dimensional images representing vascular anatomy and functional blood oxygenation parameters at video rate. Sufficient contrast was achieved at depths beyond 2 cm within dense breasts without compromising the real-time imaging performance. The suggested solution may thus find applicability as a standalone or supplemental screening tool for early detection and follow-up of carcinomas in radiographically-dense breasts. Volumetric handheld optoacoustic tomography scanner uses safe pulses of near-infrared light to render three-dimensional images of deep vascular anatomy, blood oxygenation and breast parenchyma at video rate.
Collapse
Affiliation(s)
- X Luís Deán-Ben
- Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg, Germany
| | - Thomas F Fehm
- Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg, Germany
- Faculty of Medicine, Technische Universität München, Munich, Germany
| | - Monika Gostic
- Neurogenetics Group, School of Medicine, University of St. Andrews, Scotland, United Kingdom
| | - Daniel Razansky
- Institute of Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg, Germany.
- Faculty of Medicine, Technische Universität München, Munich, Germany.
| |
Collapse
|
32
|
Lindner C, Mora M, Farzam P, Squarcia M, Johansson J, Weigel UM, Halperin I, Hanzu FA, Durduran T. Diffuse Optical Characterization of the Healthy Human Thyroid Tissue and Two Pathological Case Studies. PLoS One 2016; 11:e0147851. [PMID: 26815533 PMCID: PMC4731400 DOI: 10.1371/journal.pone.0147851] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 01/08/2016] [Indexed: 12/17/2022] Open
Abstract
The in vivo optical and hemodynamic properties of the healthy (n = 22) and pathological (n = 2) human thyroid tissue were measured non-invasively using a custom time-resolved spectroscopy (TRS) and diffuse correlation spectroscopy (DCS) system. Medical ultrasound was used to guide the placement of the hand-held hybrid optical probe. TRS measured the absorption and reduced scattering coefficients (μa, μs′) at three wavelengths (690, 785 and 830 nm) to derive total hemoglobin concentration (THC) and oxygen saturation (StO2). DCS measured the microvascular blood flow index (BFI). Their dependencies on physiological and clinical parameters and positions along the thyroid were investigated and compared to the surrounding sternocleidomastoid muscle. The THC in the thyroid ranged from 131.9 μM to 144.8 μM, showing a 25–44% increase compared to the surrounding sternocleidomastoid muscle tissue. The blood flow was significantly higher in the thyroid (BFIthyroid = 16.0 × 10-9 cm2/s) compared to the muscle (BFImuscle = 7.8 × 10-9 cm2/s), while StO2 showed a small (StO2, muscle = 63.8% to StO2, thyroid = 68.4%), yet significant difference. Two case studies with thyroid nodules underwent the same measurement protocol prior to thyroidectomy. Their THC and BFI reached values around 226.5 μM and 62.8 × 10-9 cm2/s respectively showing a clear contrast to the nodule-free thyroid tissue as well as the general population. The initial characterization of the healthy and pathologic human thyroid tissue lays the ground work for the future investigation on the use of diffuse optics in thyroid cancer screening.
Collapse
Affiliation(s)
- Claus Lindner
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- * E-mail:
| | - Mireia Mora
- Department of Endocrinology and Nutrition, Hospital Clínic, Barcelona, Spain
- Institut d’Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
| | - Parisa Farzam
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | | | - Johannes Johansson
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Udo M. Weigel
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- Hemophotonics S.L., Mediterranean Technology Park, Castelldefels (Barcelona), Spain
| | - Irene Halperin
- Department of Endocrinology and Nutrition, Hospital Clínic, Barcelona, Spain
- Institut d’Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
| | - Felicia A. Hanzu
- Department of Endocrinology and Nutrition, Hospital Clínic, Barcelona, Spain
- Institut d’Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
| | - Turgut Durduran
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| |
Collapse
|
33
|
Xu C, Vavadi H, Merkulov A, Li H, Erfanzadeh M, Mostafa A, Gong Y, Salehi H, Tannenbaum S, Zhu Q. Ultrasound-Guided Diffuse Optical Tomography for Predicting and Monitoring Neoadjuvant Chemotherapy of Breast Cancers: Recent Progress. ULTRASONIC IMAGING 2016; 38:5-18. [PMID: 25887527 PMCID: PMC5056904 DOI: 10.1177/0161734615580280] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
In this manuscript, we review the current progress of utilizing ultrasound-guided diffuse optical tomography (US-guided DOT) for predicting and monitoring neoadjuvant chemotherapy (NAC) outcomes of breast cancer patients. We also report the recent advance on optical tomography systems toward portable and robust clinical use at multiple clinical sites. The first patient who has been closely monitored before NAC, at day 2, day 8, end of first three cycles of NAC, and before surgery is given as an example to demonstrate the potential of US-guided DOT technique.
Collapse
Affiliation(s)
- Chen Xu
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Hamed Vavadi
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Alex Merkulov
- University of Connecticut Health Center, Farmington, CT, USA
| | - Hai Li
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | - Mohsen Erfanzadeh
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Atahar Mostafa
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | - Yanping Gong
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | - Hassan Salehi
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | | | - Quing Zhu
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| |
Collapse
|
34
|
Xu C, Vavadi H, Merkulov A, Li H, Erfanzadeh M, Mostafa A, Gong Y, Salehi H, Tannenbaum S, Zhu Q. Ultrasound-Guided Diffuse Optical Tomography for Predicting and Monitoring Neoadjuvant Chemotherapy of Breast Cancers: Recent Progress. ULTRASONIC IMAGING 2016. [PMID: 25887527 DOI: 10.1177/016173461558028010.1177/0161734615580280] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
In this manuscript, we review the current progress of utilizing ultrasound-guided diffuse optical tomography (US-guided DOT) for predicting and monitoring neoadjuvant chemotherapy (NAC) outcomes of breast cancer patients. We also report the recent advance on optical tomography systems toward portable and robust clinical use at multiple clinical sites. The first patient who has been closely monitored before NAC, at day 2, day 8, end of first three cycles of NAC, and before surgery is given as an example to demonstrate the potential of US-guided DOT technique.
Collapse
Affiliation(s)
- Chen Xu
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Hamed Vavadi
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Alex Merkulov
- University of Connecticut Health Center, Farmington, CT, USA
| | - Hai Li
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | - Mohsen Erfanzadeh
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| | - Atahar Mostafa
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | - Yanping Gong
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | - Hassan Salehi
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA
| | | | - Quing Zhu
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, USA Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
| |
Collapse
|
35
|
He L, Lin Y, Huang C, Irwin D, Szabunio MM, Yu G. Noncontact diffuse correlation tomography of human breast tumor. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:86003. [PMID: 26259706 PMCID: PMC4688914 DOI: 10.1117/1.jbo.20.8.086003] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Accepted: 07/09/2015] [Indexed: 05/19/2023]
Abstract
Our first step to adapt our recently developed noncontact diffuse correlation tomography (ncDCT) system for three-dimensional (3-D) imaging of blood flow distribution in human breast tumors is reported. A commercial 3-D camera was used to obtain breast surface geometry, which was then converted to a solid volume mesh. An ncDCT probe scanned over a region of interest on the mesh surface and the measured boundary data were combined with a finite element framework for 3-D image reconstruction of blood flow distribution. This technique was tested in computer simulations and in vivo human breasts with low-grade carcinoma. Results from computer simulations suggest that relatively high accuracy can be achieved when the entire tumor is within the sensitive region of diffuse light. Image reconstruction with a priori knowledge of the tumor volume and location can significantly improve the accuracy in recovery of tumor blood flow contrasts. In vivo imaging results from two breast carcinomas show higher average blood flow contrasts (5.9- and 10.9-fold) in the tumor regions compared to the surrounding tissues, which are comparable with previous findings using diffuse correlation spectroscopy. The ncDCT system has the potential to image blood flow distributions in soft and vulnerable tissues without distorting tissue hemodynamics
Collapse
Affiliation(s)
- Lian He
- University of Kentucky, Department of Biomedical Engineering, 143 Graham Avenue, Lexington, Kentucky 40506, United States
| | - Yu Lin
- University of Kentucky, Department of Biomedical Engineering, 143 Graham Avenue, Lexington, Kentucky 40506, United States
| | - Chong Huang
- University of Kentucky, Department of Biomedical Engineering, 143 Graham Avenue, Lexington, Kentucky 40506, United States
| | - Daniel Irwin
- University of Kentucky, Department of Biomedical Engineering, 143 Graham Avenue, Lexington, Kentucky 40506, United States
| | - Margaret M. Szabunio
- University of Kentucky, Markey Cancer Center, Division of Women’s Radiology, 800 Rose Street, Lexington, Kentucky 40536, United States
| | - Guoqiang Yu
- University of Kentucky, Department of Biomedical Engineering, 143 Graham Avenue, Lexington, Kentucky 40506, United States
- Address all correspondence to: Guoqiang Yu, E-mail:
| |
Collapse
|
36
|
Taroni P, Quarto G, Pifferi A, Abbate F, Balestreri N, Menna S, Cassano E, Cubeddu R. Breast tissue composition and its dependence on demographic risk factors for breast cancer: non-invasive assessment by time domain diffuse optical spectroscopy. PLoS One 2015; 10:e0128941. [PMID: 26029912 PMCID: PMC4452361 DOI: 10.1371/journal.pone.0128941] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2015] [Accepted: 05/01/2015] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Breast tissue composition is recognized as a strong and independent risk factor for breast cancer. It is a heritable feature, but is also significantly affected by several other elements (e.g., age, menopause). Nowadays it is quantified by mammographic density, thus requiring the use of ionizing radiation. Optical techniques are absolutely non-invasive and have already proved effective in the investigation of biological tissues, as they are sensitive to tissue composition and structure. METHODS Time domain diffuse optical spectroscopy was performed at 7 wavelengths (635-1060 nm) on 200 subjects to derive their breast tissue composition (in terms of water, lipid and collagen content), blood parameters (total hemoglobin content and oxygen saturation level), and information on the microscopic structure (scattering amplitude and power). The dependence of all optically-derived parameters on age, menopausal status, body mass index, and use of oral contraceptives, and the correlation with mammographic density were investigated. RESULTS Younger age, premenopausal status, lower body mass index values, and use of oral contraceptives all correspond to significantly higher water, collagen and total hemoglobin content, and lower lipid content (always p < 0.05 and often p < 10-4), while oxygen saturation level and scattering parameters show significant dependence only on some conditions. Even when age-adjusted groups of subjects are compared, several optically derived parameters (and in particular always collagen and total hemoglobin content) remain significantly different. CONCLUSIONS Time domain diffuse optical spectroscopy can probe non-invasively breast tissue composition and physiologic blood parameters, and provide information on tissue structure. The measurement is suitable for in vivo studies and monitoring of changes in breast tissue (e.g., with age, lifestyle, chemotherapy, etc.) and to gain insight into related processes, like the origin of cancer risk associated with breast density.
Collapse
Affiliation(s)
- Paola Taroni
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- * E-mail:
| | - Giovanna Quarto
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| | - Antonio Pifferi
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Francesca Abbate
- European Institute of Oncology, Breast Imaging Unit, Milano, Italy
| | - Nicola Balestreri
- European Institute of Oncology, Department of Radiology, Milano, Italy
| | - Simona Menna
- European Institute of Oncology, Breast Imaging Unit, Milano, Italy
| | - Enrico Cassano
- European Institute of Oncology, Breast Imaging Unit, Milano, Italy
| | - Rinaldo Cubeddu
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| |
Collapse
|
37
|
Zhu Q, Wang L, Tannenbaum S, Ricci A, DeFusco P, Hegde P. Pathologic response prediction to neoadjuvant chemotherapy utilizing pretreatment near-infrared imaging parameters and tumor pathologic criteria. Breast Cancer Res 2014; 16:456. [PMID: 25349073 PMCID: PMC4303135 DOI: 10.1186/s13058-014-0456-0] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2013] [Accepted: 10/06/2014] [Indexed: 01/06/2023] Open
Abstract
Introduction The purpose of this study is to develop a prediction model utilizing tumor hemoglobin parameters measured by ultrasound-guided near-infrared optical tomography (US-NIR) in conjunction with standard pathologic tumor characteristics to predict pathologic response before neoadjuvant chemotherapy (NAC) is given. Methods Thirty-four patients’ data were retrospectively analyzed using a multiple logistic regression model to predict response. These patients were split into 30 groups of training (24 tumors) and testing (12 tumors) for cross validation. Tumor vascularity was assessed using US-NIR measurements of total hemoglobin (tHb), oxygenated (oxyHb) and deoxygenated hemoglobin (deoxyHb) concentrations acquired before treatment. Tumor pathologic variables of tumor type, Nottingham score, mitotic index, the estrogen and progesterone receptors and human epidermal growth factor receptor 2 acquired before NAC in biopsy specimens were also used in the prediction model. The patients’ pathologic response was graded based on the Miller-Payne system. The overall performance of the prediction models was evaluated using receiver operating characteristic (ROC) curves. The quantitative measures were sensitivity, specificity, positive and negative predictive values (PPV and NPV) and the area under the ROC curve (AUC). Results Utilizing tumor pathologic variables alone, average sensitivity of 56.8%, average specificity of 88.9%, average PPV of 84.8%, average NPV of 70.9% and average AUC of 84.0% were obtained from the testing data. Among the hemoglobin predictors with and without tumor pathological variables, the best predictor was tHb combined with tumor pathological variables, followed by oxyHb with pathological variables. When tHb was included with tumor pathological variables as an additional predictor, the corresponding measures improved to 79%, 94%, 90%, 86% and 92.4%, respectively. When oxyHb was included with tumor variables as an additional predictor, these measures improved to 77%, 85%, 83%, 83% and 90.6%, respectively. The addition of tHb or oxyHb significantly improved the prediction sensitivity, NPV and AUC compared with using tumor pathological variables alone. Conclusions These initial findings indicate that combining widely used tumor pathologic variables with hemoglobin parameters determined by US-NIR may provide a powerful tool for predicting patient pathologic response to NAC before the start of treatment. Trial registration ClincalTrials.gov ID: NCT00908609 (registered 22 May 2009) Electronic supplementary material The online version of this article (doi:10.1186/s13058-014-0456-0) contains supplementary material, which is available to authorized users.
Collapse
|
38
|
Jiang S, Pogue BW, Kaufman PA, Gui J, Jermyn M, Frazee TE, Poplack SP, DiFlorio-Alexander R, Wells WA, Paulsen KD. Predicting breast tumor response to neoadjuvant chemotherapy with diffuse optical spectroscopic tomography prior to treatment. Clin Cancer Res 2014; 20:6006-15. [PMID: 25294916 DOI: 10.1158/1078-0432.ccr-14-1415] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
PURPOSE To determine whether pretreatment biomarkers obtained from diffuse optical spectroscopic tomographic (DOST) imaging predicts breast tumor response to neoadjuvant chemotherapy (NAC), which would have value to potentially eliminate delays in prescribing definitive local regional therapy that may occur from a standard complete 6- to 8-month course of NAC. EXPERIMENTAL DESIGN Nineteen patients undergoing NAC were imaged with DOST before, during, and after treatment. The DOST images of total hemoglobin concentration (HbT), tissue oxygen saturation (StO2), and water (H2O) fraction at different time points have been used for testing the abilities of differentiating patients having pathologic complete response (pCR) versus pathologic incomplete response (pIR). RESULTS Significant differences (P < 0.001, AUC = 1.0) were found between pCR patients versus pIR in outcome, based on the percentage change in tumor HbT within the first cycle of treatment. In addition, pretreatment tumor HbT (pretreatment HbT) relative to the contralateral breast was statistically significant (P = 0.01, AUC = 0.92) in differentiating pCR from pIR. CONCLUSIONS This is the first clinical evidence that DOST HbT may differentiate the two groups with predictive significance based on data acquired before NAC even begins. The study also demonstrates the potential of accelerating the validation of optimal NAC regimens through future randomized clinical trials by reducing the number of patients required and the length of time they need to be followed by using a validated imaging surrogate as an outcome measure.
Collapse
Affiliation(s)
- Shudong Jiang
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
| | - Brian W Pogue
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Peter A Kaufman
- Department of Medicine, Giesel School of Medicine, Hanover, New Hampshire
| | - Jiang Gui
- Department of Community and Family Medicine, Giesel School of Medicine, Hanover, New Hampshire
| | - Michael Jermyn
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
| | - Tracy E Frazee
- Department of Diagnostic Radiology, Giesel School of Medicine, Hanover, New Hampshire
| | - Steven P Poplack
- Department of Diagnostic Radiology, Giesel School of Medicine, Hanover, New Hampshire
| | | | - Wendy A Wells
- Department of Pathology, Giesel School of Medicine, Hanover, New Hampshire
| | - Keith D Paulsen
- Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire. Department of Diagnostic Radiology, Giesel School of Medicine, Hanover, New Hampshire
| |
Collapse
|
39
|
Choe R, Putt ME, Carlile PM, Durduran T, Giammarco JM, Busch DR, Jung KW, Czerniecki BJ, Tchou J, Feldman MD, Mies C, Rosen MA, Schnall MD, DeMichele A, Yodh AG. Optically measured microvascular blood flow contrast of malignant breast tumors. PLoS One 2014; 9:e99683. [PMID: 24967878 PMCID: PMC4072684 DOI: 10.1371/journal.pone.0099683] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Accepted: 05/16/2014] [Indexed: 02/03/2023] Open
Abstract
Microvascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS), a near-infrared optical method that quantifies deep tissue microvascular blood flow. Tumor-to-normal perfusion ratios are derived from thirty-two human subjects. Mean (95% confidence interval) tumor-to-normal ratio using surrounding normal tissue was 2.25 (1.92–2.63); tumor-to-normal ratio using normal tissues at the corresponding tumor location in the contralateral breast was 2.27 (1.94–2.66), and using normal tissue in the contralateral breast was 2.27 (1.90–2.70). Thus, the mean tumor-to-normal ratios were significantly different from unity irrespective of the normal tissue chosen, implying that tumors have significantly higher blood flow than normal tissues. Therefore, the study demonstrates existence of breast cancer contrast in blood flow measured by DCS. The new, optically accessible cancer contrast holds potential for cancer detection and therapy monitoring applications, and it is likely to be especially useful when combined with diffuse optical spectroscopy/tomography.
Collapse
Affiliation(s)
- Regine Choe
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
- * E-mail:
| | - Mary E. Putt
- Department of Biostatistics & Epidemiology, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Peter M. Carlile
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
| | - Turgut Durduran
- ICFO- Institut de Ciències Fotòniques, Castelldefels (Barcelona), Spain
| | - Joseph M. Giammarco
- Department of Astronomy & Physics, Eastern University, St. Davids, Pennsylvania, United States of America
| | - David R. Busch
- Department of Physics & Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, United States of America
| | - Ki Won Jung
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, United States of America
| | - Brian J. Czerniecki
- Department of Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Julia Tchou
- Department of Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Michael D. Feldman
- Department of Pathology and Laboratory Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Carolyn Mies
- Department of Pathology and Laboratory Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Mark A. Rosen
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Mitchell D. Schnall
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Angela DeMichele
- Department of Medicine (Hematology/Oncology), Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Arjun G. Yodh
- Department of Physics & Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| |
Collapse
|
40
|
Busch DR, Choe R, Durduran T, Friedman DH, Baker WB, Maidment AD, Rosen MA, Schnall MD, Yodh AG. Blood flow reduction in breast tissue due to mammographic compression. Acad Radiol 2014; 21:151-61. [PMID: 24439328 DOI: 10.1016/j.acra.2013.10.009] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2013] [Revised: 10/08/2013] [Accepted: 10/14/2013] [Indexed: 10/25/2022]
Abstract
RATIONALE AND OBJECTIVES This study measures hemodynamic properties such as blood flow and hemoglobin concentration and oxygenation in the healthy human breast under a wide range of compressive loads. Because many breast-imaging technologies derive contrast from the deformed breast, these load-dependent vascular responses affect contrast agent-enhanced and hemoglobin-based breast imaging. METHODS Diffuse optical and diffuse correlation spectroscopies were used to measure the concentrations of oxygenated and deoxygenated hemoglobin, lipid, water, and microvascular blood flow during axial breast compression in the parallel-plate transmission geometry. RESULTS Significant reductions (P < .01) in total hemoglobin concentration (∼30%), blood oxygenation (∼20%), and blood flow (∼87%) were observed under applied pressures (forces) of up to 30 kPa (120 N) in 15 subjects. Lipid and water concentrations changed <10%. CONCLUSIONS Imaging protocols based on injected contrast agents should account for variation in tissue blood flow due to mammographic compression. Similarly, imaging techniques that depend on endogenous blood contrasts will be affected by breast compression during imaging.
Collapse
|
41
|
Durduran T, Yodh AG. Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement. Neuroimage 2014; 85 Pt 1:51-63. [PMID: 23770408 PMCID: PMC3991554 DOI: 10.1016/j.neuroimage.2013.06.017] [Citation(s) in RCA: 322] [Impact Index Per Article: 29.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 05/10/2013] [Accepted: 06/06/2013] [Indexed: 12/25/2022] Open
Abstract
Diffuse correlation spectroscopy (DCS) uses the temporal fluctuations of near-infrared (NIR) light to measure cerebral blood flow (CBF) non-invasively. Here, we provide a brief history of DCS applications in the brain with an emphasis on the underlying physical ideas, common instrumentation and validation. Then we describe recent clinical research that employs DCS-measured CBF as a biomarker of patient well-being, and as an indicator of hemodynamic and metabolic responses to functional stimuli.
Collapse
Affiliation(s)
- Turgut Durduran
- ICFO- Institut de Ciències Fotòniques, Mediterranean Technology Park, 08860 Castelldefels, Barcelona, Spain.
| | | |
Collapse
|
42
|
Enfield LC, Hebden JC, Gibson AP. The reproducibility of optical mammography in healthy volunteers. Phys Med Biol 2013; 58:4579-94. [PMID: 23771048 DOI: 10.1088/0031-9155/58/13/4579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This study was designed to determine the reproducibility of optical mammography. Eight healthy pre-menopausal volunteers were scanned at different time intervals (minutes, weeks and months apart) to investigate the effects of within-subject variation, between-subject variation and systematic variations on both the raw data and images. The study shows that the greatest source of variation in optical mammography raw data and images is between different subjects, and scans of the same subject are very reproducible. The averaged total haemoglobin concentration from the eight volunteers was (24 ± 10) µM, and the average tissue oxygen saturation was (70 ± 10)%, which is comparable with other data in the literature. The average absorption coefficient at 780 nm was (0.0048 ± 0.0017) mm(-1) and the average reduced scatter coefficient at 780 nm was (0.80 ± 0.12) mm(-1). Again, this is comparable with published values. When our data are combined with the published values, the weighted average total haemoglobin concentration and tissue oxygen saturation for pre-menopausal breasts are (29 ± 8) µM and (73 ± 3)%, respectively. The results of our study show that we can be reassured that any changes within the tumour region seen during neoadjuvant therapy are likely to be due to a real physiological response to treatment, as the physiological properties of the breast remain relatively constant. However, in this study, we cannot distinguish between a tumour response to treatment and systemic changes in the healthy breast.
Collapse
Affiliation(s)
- L C Enfield
- Department of Medical Physics and Bioengineering, UCL, Gower Street, London WC1E 6BT, UK
| | | | | |
Collapse
|
43
|
Busch DR, Choe R, Durduran T, Yodh AG. Towards non-invasive characterization of breast cancer and cancer metabolism with diffuse optics. PET Clin 2013; 8. [PMID: 24244206 DOI: 10.1016/j.cpet.2013.04.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
We review recent developments in diffuse optical imaging and monitoring of breast cancer, i.e. optical mammography. Optical mammography permits non-invasive, safe and frequent measurement of tissue hemodynamics oxygen metabolism and components (lipids, water, etc.), the development of new compound indices indicative of the risk and malignancy, and holds potential for frequent non-invasive longitudinal monitoring of therapy progression.
Collapse
|
44
|
Carp SA, Sajjadi AY, Wanyo CM, Fang Q, Specht MC, Schapira L, Moy B, Bardia A, Boas DA, Isakoff SJ. Hemodynamic signature of breast cancer under fractional mammographic compression using a dynamic diffuse optical tomography system. BIOMEDICAL OPTICS EXPRESS 2013; 4:2911-24. [PMID: 24409390 PMCID: PMC3862147 DOI: 10.1364/boe.4.002911] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 10/24/2013] [Accepted: 10/25/2013] [Indexed: 05/03/2023]
Abstract
Near infrared dynamic diffuse optical tomography measurements of breast hemodynamics during fractional mammographic compression offer a novel contrast mechanism for detecting breast cancer and monitoring chemotherapy. Tissue viscoelastic relaxation during the compression period leads to a slow reduction in the compression force and reveals biomechanical and metabolic differences between healthy and lesion tissue. We measured both the absolute values and the temporal evolution of hemoglobin concentration during 25-35 N of compression for 22 stage II and III breast cancer patients scheduled to undergo neoadjuvant chemotherapy. 17 patients were included in the group analysis (average tumor size 3.2 cm, range: 1.3-5.7 cm). We observed a statistically significant differential decrease in total and oxy-hemoglobin, as well as in hemoglobin oxygen saturation in tumor areas vs. healthy tissue, as early as 30 seconds into the compression period. The hemodynamic contrast is likely driven by the higher tumor stiffness and different viscoelastic relaxation rate, as well as the higher tumor oxygen metabolism rate.
Collapse
Affiliation(s)
- Stefan A Carp
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA ; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA ; These authors contributed equally to this work
| | - Amir Y Sajjadi
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA ; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA ; These authors contributed equally to this work ;
| | - Christy M Wanyo
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA
| | - Qianqian Fang
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA ; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA
| | - Michelle C Specht
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA ; Department of Surgery, Harvard Medical School, Boston, MA 02114, USA
| | - Lidia Schapira
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA ; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA
| | - Beverly Moy
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA ; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA
| | - Aditya Bardia
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA ; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA
| | - David A Boas
- Optics Division, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA 02129, USA ; Department of Radiology, Harvard Medical School, Charlestown, MA 02129, USA
| | - Steven J Isakoff
- Massachusetts General Hospital Cancer Center, Boston, MA 02114, USA ; Department of Medicine, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
45
|
Busch DR, Choe R, Rosen MA, Guo W, Durduran T, Feldman MD, Mies C, Czerniecki BJ, Tchou J, DeMichele A, Schnall MD, Yodh AG. Optical malignancy parameters for monitoring progression of breast cancer neoadjuvant chemotherapy. BIOMEDICAL OPTICS EXPRESS 2013; 4:105-21. [PMID: 23304651 PMCID: PMC3539198 DOI: 10.1364/boe.4.000105] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Revised: 11/27/2012] [Accepted: 11/28/2012] [Indexed: 05/03/2023]
Abstract
We introduce and demonstrate use of a novel, diffuse optical tomography (DOT) based breast cancer signature for monitoring progression of neoadjuvant chemotherapy. This signature, called probability of malignancy, is obtained by statistical image analysis of total hemoglobin concentration, blood oxygen saturation, and scattering coefficient distributions in the breast tomograms of a training-set population with biopsy-confirmed breast cancers. A pilot clinical investigation adapts this statistical image analysis approach for chemotherapy monitoring of three patients. Though preliminary, the study shows how to use the malignancy parameter for separating responders from partial-responders and demonstrates the potential utility of the methodology compared to traditional DOT quantification schemes.
Collapse
Affiliation(s)
- David R. Busch
- Dept. of Physics and Astronomy, University of Pennsylvania, 209 S. 33rd St.,
Philadelphia, PA 19104 USA
| | - Regine Choe
- Dept. of Biomedical Engineering, University of Rochester NY 14627
USA
| | - Mark A. Rosen
- Dept. of Radiology, University of Pennsylvania, PA 19104
USA
| | - Wensheng Guo
- Dept. of Biostatistics, University of Pennsylvania, PA 19104
USA
| | - Turgut Durduran
- Institut de Ciències Fotòniques, Castelldefels, Barcelona
Spain
| | - Michael D. Feldman
- Dept. of Pathology and Laboratory Medicine, University of Pennsylvania, PA 19104
USA
| | - Carolyn Mies
- Dept. of Pathology and Laboratory Medicine, University of Pennsylvania, PA 19104
USA
| | | | - Julia Tchou
- Dept. of Surgery, University of Pennsylvania, PA 19104 USA
| | - Angela DeMichele
- Depts. of Medicine (Hematology/Oncology) and Epidemiology, University of
Pennsylvania, PA 19104 USA
| | | | - Arjun G. Yodh
- Dept. of Physics and Astronomy, University of Pennsylvania, 209 S. 33rd St.,
Philadelphia, PA 19104 USA
| |
Collapse
|