1
|
Platelet Adhesion and Thrombus Formation in Microchannels: The Effect of Assay-Dependent Variables. Int J Mol Sci 2020; 21:ijms21030750. [PMID: 31979370 PMCID: PMC7037340 DOI: 10.3390/ijms21030750] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 01/13/2020] [Accepted: 01/21/2020] [Indexed: 12/12/2022] Open
Abstract
Microfluidic flow chambers (MFCs) allow the study of platelet adhesion and thrombus formation under flow, which may be influenced by several variables. We developed a new MFC, with which we tested the effects of different variables on the results of platelet deposition and thrombus formation on a collagen-coated surface. Methods: Whole blood was perfused in the MFC over collagen Type I for 4 min at different wall shear rates (WSR) and different concentrations of collagen-coating solutions, keeping blood samples at room temperature or 37 °C before starting the experiments. In addition, we tested the effects of the antiplatelet agent acetylsalicylic acid (ASA) (antagonist of cyclooxygenase-1, 100 µM) and cangrelor (antagonist of P2Y12, 1 µM). Results: Platelet deposition on collagen (I) was not affected by the storage temperature of the blood before perfusion (room temperature vs. 37 °C); (II) was dependent on a shear rate in the range between 300/s and 1700/s; and (III) was influenced by the collagen concentration used to coat the microchannels up to a value of 10 µg/mL. ASA and cangrelor did not cause statistically significant inhibition of platelet accumulation, except for ASA at low collagen concentrations. Conclusions: Platelet deposition on collagen-coated surfaces is a shear-dependent process, not influenced by the collagen concentration beyond a value of 10 µg/mL. However, the inhibitory effect of antiplatelet drugs is better observed using low concentrations of collagen.
Collapse
|
2
|
Disease diagnostics using hydrodynamic flow focusing in microfluidic devices: Beyond flow cytometry. Biomed Eng Lett 2020; 10:241-257. [PMID: 32431954 DOI: 10.1007/s13534-019-00144-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 11/23/2019] [Accepted: 11/28/2019] [Indexed: 01/09/2023] Open
Abstract
The multi-disciplinary field of microfluidics has the potential to provide solutions to a diverse set of problems. It offers the advantages of high-throughput, continuous, rapid and expeditious analysis requiring minute quantities of sample. However, even as this field has yielded many mass-manufacturable and cost-efficient point-of-care devices, its direct and practical applications into the field of disease diagnostics still remain limited and largely overlooked by the industry. This review focuses on the phenomenon of hydrodynamic focusing and its potential to materialize solutions for appropriate diagnosis and prognosis. The study aims to look beyond its intended cytometric applications and focus on unambiguous disease detection, monitoring, drug delivery, studies conducted on DNA and highlight the instances in the scientific literature that have proposed such approach.
Collapse
|
3
|
Szydzik C, Brazilek RJ, Akbaridoust F, de Silva C, Moon M, Marusic I, Ooi ASH, Nandurkar HH, Hamilton JR, Mitchell A, Nesbitt WS. Active Micropump-Mixer for Rapid Antiplatelet Drug Screening in Whole Blood. Anal Chem 2019; 91:10830-10839. [PMID: 31343155 DOI: 10.1021/acs.analchem.9b02486] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
There is a need for scalable automated lab-on-chip systems incorporating precise hemodynamic control that can be applied to high-content screening of new more efficacious antiplatelet therapies. This paper reports on the development and characterization of a novel active micropump-mixer microfluidic to address this need. Using a novel reciprocating elastomeric micropump design, we take advantage of the flexible structural and actuation properties of this framework to manage the hemodynamics for on-chip platelet thrombosis assay on type 1 fibrillar collagen, using whole blood. By characterizing and harnessing the complex three-dimensional hemodynamics of the micropump operation in conjunction with a microvalve controlled reagent injection system we demonstrate that this prototype can act as a real-time assay of antiplatelet drug pharmacokinetics. In a proof-of-concept preclinical application, we utilize this system to investigate the way in which rapid dosing of human whole blood with isoform selective inhibitors of phosphatidylinositol 3-kinase dose dependently modulate platelet thrombus dynamics. This modular system exhibits utility as an automated multiplexable assay system with applications to high-content chemical library screening of new antiplatelet therapies.
Collapse
Affiliation(s)
- Crispin Szydzik
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia.,School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia
| | - Rose J Brazilek
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Farzan Akbaridoust
- School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia.,Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia
| | - Charitha de Silva
- Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia.,School of Mechanical and Manufacturing Engineering , The University of New South Wales , Sydney , New South Wales 2052 , Australia
| | - Mitchell Moon
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Ivan Marusic
- Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia
| | - Andrew S H Ooi
- Department of Mechanical Engineering, Melbourne School of Engineering , The University of Melbourne , Melbourne , Victoria 3010 , Australia
| | - Harshal H Nandurkar
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Justin R Hamilton
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia
| | - Arnan Mitchell
- School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia
| | - Warwick S Nesbitt
- The Australian Centre for Blood Diseases , Monash University , 99 Commercial Road , Melbourne , Victoria 3004 , Australia.,School of Engineering , RMIT University , 124 La Trobe Street , Melbourne , Victoria 3000 , Australia
| |
Collapse
|
4
|
Lordkipanidzé M, Hvas AM, Harrison P. Clinical Tests of Platelet Function. Platelets 2019. [DOI: 10.1016/b978-0-12-813456-6.00033-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
5
|
Kennedy C, Wong L, Sexton DJ, Cowman J, Oglesby I, Kenny M, Conlon PJ, Kenny D. Successful kidney transplantation normalizes platelet function. Clin Kidney J 2018; 11:574-580. [PMID: 30087773 PMCID: PMC6070122 DOI: 10.1093/ckj/sfx148] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 11/27/2017] [Indexed: 12/23/2022] Open
Abstract
Background Uraemic platelet dysfunction is not completely understood, in part due to non-physiological platelet function assays. We have developed a physiological flow-based assay that quantifies platelet function in microlitre volumes of blood under arterial shear. The aim of this study was to characterize platelet function before and after kidney transplantation. Methods Ten patients scheduled for living donor kidney transplant surgery and nine healthy controls were analysed using the assay. The motional parameters of platelet behaviour on von Willebrand factor (VWF) were recorded using customized platelet tracking software. The assay was repeated 3–8 weeks post-transplant in the transplant group and at an interval of >3 weeks in normal healthy volunteers. Results Platelet–VWF interactions were markedly reduced in the 10 pre-transplant patients compared with the healthy controls. In seven patients with immediate graft function, dynamic platelet function returned to normal (despite a small decrease in haemoglobin and haematocrit), but remained markedly abnormal in the three patients with delayed graft function (DGF). Conclusions Dynamic platelet function returned to normal following transplantation in those with immediate graft function. This early improvement was not observed in those with DGF. There may be important clinical implications, as patients with DGF are more likely to undergo invasive procedures, including transplant biopsies and insertion of central venous catheters.
Collapse
Affiliation(s)
- Claire Kennedy
- Department of Nephrology, Beaumont Hospital, Dublin, Ireland.,Department of Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Limy Wong
- Department of Nephrology, Beaumont Hospital, Dublin, Ireland
| | - Donal J Sexton
- Department of Nephrology, Beaumont Hospital, Dublin, Ireland
| | - Jonathan Cowman
- Department of Molecular and Cellular Therapeutics, Royal College of Surgeons in Ireland, Dublin, Ireland.,Irish Centre for Vascular Biology, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Irene Oglesby
- Department of Molecular and Cellular Therapeutics, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Martin Kenny
- Department of Molecular and Cellular Therapeutics, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Peter J Conlon
- Department of Nephrology, Beaumont Hospital, Dublin, Ireland.,Department of Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Dermot Kenny
- Department of Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland.,Irish Centre for Vascular Biology, Royal College of Surgeons in Ireland, Dublin, Ireland
| |
Collapse
|
6
|
Ward J, Dunne E, Bishop D, Boyd A, Kenny D, Meenan BJ. Entrapment of Autologous von Willebrand Factor on Polystyrene/Poly(methyl methacrylate) Demixed Surfaces. Polymers (Basel) 2017; 9:polym9120700. [PMID: 30966006 PMCID: PMC6419233 DOI: 10.3390/polym9120700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 11/30/2017] [Accepted: 12/06/2017] [Indexed: 12/01/2022] Open
Abstract
Human platelets play a vital role in haemostasis, pathological bleeding and thrombosis. The haemostatic mechanism is concerned with the control of bleeding from injured blood vessels, whereby platelets interact with the damaged inner vessel wall to form a clot (thrombus) at the site of injury. This adhesion of platelets and their subsequent aggregation is dependent on the presence of the blood protein von Willebrand Factor (vWF). It is proposed here that the entrapment of vWF on a substrate surface offers the opportunity to assess an individual’s platelet function in a clinical diagnostic context. Spin coating from demixed solutions of polystyrene (PS) and poly(methyl methacrylate) (PMMA) onto glass slides has been shown previously to support platelet adhesion but the mechanism by which this interaction occurs, including the role of vWF, is not fully understood. In this work, we report a study of the interaction of platelets in whole blood with surfaces produced by spin coating from a solution of a weight/weight mixture of a 25% PS and 75% PMMA (25PS/75PMMA) in chloroform in the context of the properties required for their use as a Dynamic Platelet Function Assay (DPFA) substrate. Atomic Force Microscopy (AFM) indicates the presence of topographical features on the polymer demixed surfaces in the sub-micron to nanometer range. X-ray Photoelectron Spectroscopy (XPS) analysis confirms that the uppermost surface chemistry of the coatings is solely that of PMMA. The deliberate addition of various amounts of 50 μm diameter PS microspheres to the 25PS/75PMMA system has been shown to maintain the PMMA chemistry, but to significantly change the surface topography and to subsequently effect the scale of the resultant platelet interactions. By blocking specific platelet binding sites, it has been shown that their interaction with these surfaces is a consequence of the entrapment and build-up of vWF from the same whole blood sample.
Collapse
Affiliation(s)
- Joanna Ward
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Jordanstown BT37 0QB, UK.
| | - Eimear Dunne
- Royal College of Surgeons in Ireland, 123 St. Stephen's Green, Dublin 2, Ireland.
| | - David Bishop
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Jordanstown BT37 0QB, UK.
| | - Adrian Boyd
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Jordanstown BT37 0QB, UK.
| | - Dermot Kenny
- Royal College of Surgeons in Ireland, 123 St. Stephen's Green, Dublin 2, Ireland.
| | - Brian J Meenan
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Jordanstown BT37 0QB, UK.
| |
Collapse
|
7
|
Brazilek RJ, Tovar-Lopez FJ, Wong AKT, Tran H, Davis AS, McFadyen JD, Kaplan Z, Chunilal S, Jackson SP, Nandurkar H, Mitchell A, Nesbitt WS. Application of a strain rate gradient microfluidic device to von Willebrand's disease screening. LAB ON A CHIP 2017; 17:2595-2608. [PMID: 28660968 DOI: 10.1039/c7lc00498b] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Von Willebrand's disease (VWD) is the most common inherited bleeding disorder caused by either quantitative or qualitative defects of von Willebrand factor (VWF). Current tests for VWD require relatively large blood volumes, have low throughput, are time-consuming, and do not incorporate the physiologically relevant effects of haemodynamic forces. We developed a microfluidic device incorporating micro-contractions that harnesses well-defined haemodynamic strain gradients to initiate platelet aggregation in citrated whole blood. The microchannel architecture has been specifically designed to allow for continuous real-time imaging of platelet aggregation dynamics. Subjects aged ≥18 years with previously diagnosed VWD or who presented for evaluation of a bleeding disorder, where the possible diagnosis included VWD, were tested. Samples were obtained for device characterization as well as for pathology-based testing. Platelet aggregation in the microfluidic device is independent of platelet amplification loops but dependent on low-level platelet activation, GPIb/IX/V and integrin αIIbβ3 engagement. Microfluidic output directly correlates with VWF antigen levels and is able to sensitively detect aggregation defects associated with VWD subtypes. Testing demonstrated a strong correlation with standard clinical laboratory-based tests. Head-to-head comparison with PFA100® demonstrated equivalent, if not improved, sensitivity for screening aggregation defects associated with VWD. This strain rate gradient microfluidic prototype has the potential to be a clinically useful, rapid and high throughput-screening tool for VWD as well as other strain-dependent platelet disorders. In addition, the microfluidic device represents a novel approach to examine the effects of high magnitude/short duration (ms) strain rate gradients on platelet function.
Collapse
Affiliation(s)
- Rose J Brazilek
- The Australian Centre for Blood Diseases, Monash University, Alfred Medical Research and Educational Precinct, Melbourne, Victoria, Australia
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Jose B, McCluskey P, Gilmartin N, Somers M, Kenny D, Ricco AJ, Kent NJ, Basabe-Desmonts L. Self-Powered Microfluidic Device for Rapid Assay of Antiplatelet Drugs. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2016; 32:2820-8. [PMID: 26910300 DOI: 10.1021/acs.langmuir.5b03540] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
We report the development of a microfluidic device for the rapid assay in whole blood of interfacial platelet-protein interactions indicative of the efficacy of antiplatelet drugs, for example, aspirin and Plavix, two of the world's most widely used drugs, in patients with cardiovascular disease (CVD). Because platelet adhesion to surface-confined protein matrices is an interfacial phenomenon modulated by fluid shear rates at the blood/protein interface, and because such binding is a better indicator of platelet function than platelet self-aggregation, we designed, fabricated, and characterized the performance of a family of disposable, self-powered microfluidic chips with well-defined flow and interfacial shear rates suitable for small blood volumes (≤200 μL). This work demonstrates that accurate quantification of cell adhesion to protein matrices, an important interfacial biological phenomenon, can be used as a powerful diagnostic tool in those with CVD, the world's leading cause of death. To enable such measurements, we developed a simple technique to fabricate single-use self-powered chips incorporating shear control (SpearChips). These parallel-plate flow devices integrate on-chip vacuum-driven blood flow, using a predegassed elastomer component to obviate active pumping, with microcontact-printed arrays of 6-μm-diameter fluorescently labeled fibrinogen dots on a cyclic olefin polymer base plate as a means to quantitatively count platelet-protein binding events. The use of SpearChips to assess in whole blood samples the effects of GPIIb/IIIa and P2Y12 inhibitors, two important classes of "antiplatelet" drugs, is reported.
Collapse
Affiliation(s)
- Bincy Jose
- Biomedical Diagnostics Institute (BDI), Dublin City University , Dublin 9, Ireland
| | - Peter McCluskey
- Biomedical Diagnostics Institute (BDI), Dublin City University , Dublin 9, Ireland
| | - Niamh Gilmartin
- Biomedical Diagnostics Institute (BDI), Dublin City University , Dublin 9, Ireland
| | - Martin Somers
- Biomedical Diagnostics Institute (BDI), Dublin City University , Dublin 9, Ireland
| | - Dermot Kenny
- Biomedical Diagnostics Institute (BDI), Royal College of Surgeons in Ireland , Dublin 2, Ireland
| | - Antonio J Ricco
- Biomedical Diagnostics Institute (BDI), Dublin City University , Dublin 9, Ireland
| | - Nigel J Kent
- Biomedical Diagnostics Institute (BDI), Dublin City University , Dublin 9, Ireland
- Dublin Institute of Technology , Dublin 1, Ireland
| | - Lourdes Basabe-Desmonts
- Biomedical Diagnostics Institute (BDI), Dublin City University , Dublin 9, Ireland
- BIOMICs Research Group, Lascaray Ikergunea Research Center, Univ. Basque Country, Euskal Herriko Unibertsitatea UPV EHU , 01007 Vitoria, Spain
- Basque Foundation of Science, IKERBASQUE , 48013 Bilbao, Spain
| |
Collapse
|
9
|
Combariza ME, Yu X, Nesbitt WS, Mitchell A, Tovar-Lopez FJ. Nonlinear Dynamic Modelling of Platelet Aggregation via Microfluidic Devices. IEEE Trans Biomed Eng 2015; 62:1718-27. [DOI: 10.1109/tbme.2015.2403266] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
10
|
Abstract
Platelet function tests have been traditionally used to aid in the diagnosis and management of patients with bleeding problems. Given the role of platelets in atherothrombosis, several dedicated platelet function instruments are now available that are simple to use and can be used as point-of-care assays. These can provide rapid assessment of platelet function within whole blood without the requirement of sample processing. Some tests can be used to monitor antiplatelet therapy and assess risk of bleeding and thrombosis, although current guidelines advise against this. This article discusses the potential utility of tests/instruments that are available.
Collapse
Affiliation(s)
- Paul Harrison
- School of Immunity and Infection, University of Birmingham Medical School, Birmingham, UK.
| | | |
Collapse
|
11
|
The use of microfluidics in hemostasis: clinical diagnostics and biomimetic models of vascular injury. Curr Opin Hematol 2013; 20:417-23. [PMID: 23872531 DOI: 10.1097/moh.0b013e3283642186] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
PURPOSE OF REVIEW This article reviews the application of microfluidic technologies in hemostasis. The emphasis is on promising developments in devices for clinical applications and novel approaches to modeling complex hemodynamics. RECENT FINDINGS Microfluidics combined with micropatterning of prothrombotic substrates provides devices for measuring platelet function and coagulation with low blood volumes (∼100 μl) over a wide range of shear stresses. This technology has been applied to the diagnosis of bleeding and thrombotic disorders, as well as to dosing and monitoring of anticoagulation and antiplatelet agents. Microfluidic devices that mimic vascular geometries such as bifurcations, stenosis, and complex interconnected networks yield complex flow fields that have revealed new mechanisms of platelet adhesion and aggregation. Applying techniques from tissue engineering by endothelializing these networks is beginning to close the gap between in-vitro and in-vivo models of vascular injury. SUMMARY Microfluidic technology enables researchers to create in-vitro models of vascular disease with unprecedented control of the biochemical and biophysical conditions. Two promising directions are flow-dependent clinical assays and biomimetic vascular networks. These approaches are particularly well suited for modeling the microvasculature. However, caution should be used when extrapolating results from microfluidic channels to the pathophysiology of thrombosis in large arteries and veins.
Collapse
|
12
|
Ahmed MU, Saaem I, Wu PC, Brown AS. Personalized diagnostics and biosensors: a review of the biology and technology needed for personalized medicine. Crit Rev Biotechnol 2013; 34:180-96. [DOI: 10.3109/07388551.2013.778228] [Citation(s) in RCA: 139] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
13
|
Evander M, Ricco AJ, Morser J, Kovacs GTA, Leung LLK, Giovangrandi L. Microfluidic impedance cytometer for platelet analysis. LAB ON A CHIP 2013; 13:722-9. [PMID: 23282651 DOI: 10.1039/c2lc40896a] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We present the design and performance characteristics of a platelet analysis platform based on a microfluidic impedance cytometer. Dielectrophoretic focusing is used to centre cells in a fluid stream, which then forms the core of a two-phase flow (dielectric focusing). This flow then passes between electrodes for analysis by differential impedance spectroscopy at multiple frequencies from 280 kHz to 4 MHz. This approach increases the signal-to-noise ratio relative to a single-phase, unfocused stream, while minimising the shear forces to which the cells are subjected. The percentage of activated platelets before and after passage through the chip was measured using flow cytometry, and no significant change was measured. Measuring the in-phase amplitude at a single frequency is sufficient to distinguish platelets from erythrocytes. Using multi-frequency impedance measurements and discriminant analysis, resting platelets can be discriminated from activated platelets. This multifrequency impedance cytometer therefore allows ready determination of the degree of platelet activation in blood samples.
Collapse
Affiliation(s)
- Mikael Evander
- Dept. of Measurement Technology and Industrial Electrical Engineering, Lund University, Sweden.
| | | | | | | | | | | |
Collapse
|
14
|
|
15
|
Westein E, de Witt S, Lamers M, Cosemans JMEM, Heemskerk JWM. Monitoring in vitro thrombus formation with novel microfluidic devices. Platelets 2012; 23:501-9. [PMID: 22873212 DOI: 10.3109/09537104.2012.709653] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Cardiovascular disease is a major cause of mortality globally and is subject to ongoing research to improve clinical treatment. It is established that activation of platelets and coagulation are central to thrombosis, yet at different extents in the arterial and venous system. In vitro perfusion chamber technology has contributed significant knowledge on the function of platelets in the thrombotic process under shear conditions. Recent efforts to downscale this technique with a variety of microfluidic devices has opened new possibilities to study this process under precisely controlled flow conditions. Such microfluidic devices possess the capability to execute platelet function tests more quickly than current assays, while using small blood samples. Gradually becoming available to the clinic now, they may provide a new means to manage the treatment of cardiovascular diseases, although accurate validation studies still are missing. This review highlights the progress that has been made in monitoring aspects of thrombus formation using microfluidic devices.
Collapse
Affiliation(s)
- Erik Westein
- Department of Biochemistry, CARIM, Maastricht University, Maastricht, The Netherlands.
| | | | | | | | | |
Collapse
|
16
|
Gubala V, Harris LF, Ricco AJ, Tan MX, Williams DE. Point of Care Diagnostics: Status and Future. Anal Chem 2011; 84:487-515. [DOI: 10.1021/ac2030199] [Citation(s) in RCA: 832] [Impact Index Per Article: 64.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Vladimir Gubala
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Leanne F. Harris
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Antonio J. Ricco
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Ming X. Tan
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - David E. Williams
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| |
Collapse
|
17
|
Feghhi S, Sniadecki NJ. Mechanobiology of platelets: techniques to study the role of fluid flow and platelet retraction forces at the micro- and nano-scale. Int J Mol Sci 2011; 12:9009-30. [PMID: 22272117 PMCID: PMC3257114 DOI: 10.3390/ijms12129009] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2011] [Revised: 11/24/2011] [Accepted: 11/28/2011] [Indexed: 12/29/2022] Open
Abstract
Coagulation involves a complex set of events that are important in maintaining hemostasis. Biochemical interactions are classically known to regulate the hemostatic process, but recent evidence has revealed that mechanical interactions between platelets and their surroundings can also play a substantial role. Investigations into platelet mechanobiology have been challenging however, due to the small dimensions of platelets and their glycoprotein receptors. Platelet researchers have recently turned to microfabricated devices to control these physical, nanometer-scale interactions with a higher degree of precision. These approaches have enabled exciting, new insights into the molecular and biomechanical factors that affect platelets in clot formation. In this review, we highlight the new tools used to understand platelet mechanobiology and the roles of adhesion, shear flow, and retraction forces in clot formation.
Collapse
Affiliation(s)
- Shirin Feghhi
- Department of Mechanical Engineering, University of Washington, Stevens Way, Box 352600, Seattle, WA 98195, USA; E-Mail:
| | - Nathan J. Sniadecki
- Department of Mechanical Engineering, University of Washington, Stevens Way, Box 352600, Seattle, WA 98195, USA; E-Mail:
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Seattle, WA 98105, USA
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +1-206-685-6591; Fax: +1-206-685-8047
| |
Collapse
|
18
|
O'Brien S, Kent NJ, Lucitt M, Ricco AJ, McAtamney C, Kenny D, Meade G. Effective hydrodynamic shaping of sample streams in a microfluidic parallel-plate flow-assay device: matching whole blood dynamic viscosity. IEEE Trans Biomed Eng 2011; 59:374-82. [PMID: 22020664 DOI: 10.1109/tbme.2011.2172607] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We report the development of an aqueous buffer system tailored to the fluidic and hemodynamic requirements of our recently reported microfluidic platelet dynamic assay device, which uses hydrodynamic focusing to "shape" a blood sample into a thin flowing layer adjacent to its protein-functionalized surface. By matching the dynamic viscosity of whole blood (3.13 ± 0.08 mPa·s, from healthy donors), the selected buffer minimizes interfacial fluid mixing and better controls shear rate within the device, permitting platelet/protein-surface interaction assays with as little as 50 μL of whole blood. Buffers containing the viscosity-enhancing components bovine serum albumin (BSA), gelofusine/glycine, or histopaque (Ficoll gradient solution) were found not to activate platelets when incubated with blood at concentrations up to 50%, as assessed by flow cytometry quantitation of P-selectin expression and αIIbβ (3) activation. In contrast, glycerol-based buffer activated platelets (two-fold increase in P-selectin levels) at concentrations as low as 10% by volume. BSA- and gelofusine/glycine-based buffers were problematic in preparation and use, and therefore, were not used beyond initial characterization. The histopaque solution selected as the best choice for flow studies stabilizes sample contact with the device's thrombogenic surface, does not activate platelets, and does not interfere with the action of agonists added to deliberately activate platelets.
Collapse
Affiliation(s)
- Sinead O'Brien
- Biomedical Diagnostics Institute, Royal College of Surgeons in Ireland, Dublin 2, Ireland.
| | | | | | | | | | | | | |
Collapse
|
19
|
Santos-Martínez MJ, Prina-Mello A, Medina C, Radomski MW. Analysis of platelet function: role of microfluidics and nanodevices. Analyst 2011; 136:5120-6. [DOI: 10.1039/c1an15445a] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|