1
|
Rolf-Pissarczyk M, Schussnig R, Fries TP, Fleischmann D, Elefteriades JA, Humphrey JD, Holzapfel GA. Mechanisms of aortic dissection: From pathological changes to experimental and in silico models. PROGRESS IN MATERIALS SCIENCE 2025; 150:101363. [PMID: 39830801 PMCID: PMC11737592 DOI: 10.1016/j.pmatsci.2024.101363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2025]
Abstract
Aortic dissection continues to be responsible for significant morbidity and mortality, although recent advances in medical data assimilation and in experimental and in silico models have improved our understanding of the initiation and progression of the accumulation of blood within the aortic wall. Hence, there remains a pressing necessity for innovative and enhanced models to more accurately characterize the associated pathological changes. Early on, experimental models were employed to uncover mechanisms in aortic dissection, such as hemodynamic changes and alterations in wall microstructure, and to assess the efficacy of medical implants. While experimental models were once the only option available, more recently they are also being used to validate in silico models. Based on an improved understanding of the deteriorated microstructure of the aortic wall, numerous multiscale material models have been proposed in recent decades to study the state of stress in dissected aortas, including the changes associated with damage and failure. Furthermore, when integrated with accessible patient-derived medical data, in silico models prove to be an invaluable tool for identifying correlations between hemodynamics, wall stresses, or thrombus formation in the deteriorated aortic wall. They are also advantageous for model-guided design of medical implants with the aim of evaluating the deployment and migration of implants in patients. Nonetheless, the utility of in silico models depends largely on patient-derived medical data, such as chosen boundary conditions or tissue properties. In this review article, our objective is to provide a thorough summary of medical data elucidating the pathological alterations associated with this disease. Concurrently, we aim to assess experimental models, as well as multiscale material and patient data-informed in silico models, that investigate various aspects of aortic dissection. In conclusion, we present a discourse on future perspectives, encompassing aspects of disease modeling, numerical challenges, and clinical applications, with a particular focus on aortic dissection. The aspiration is to inspire future studies, deepen our comprehension of the disease, and ultimately shape clinical care and treatment decisions.
Collapse
Affiliation(s)
| | - Richard Schussnig
- High-Performance Scientific Computing, University of Augsburg, Germany
- Institute of Structural Analysis, Graz University of Technology, Austria
| | - Thomas-Peter Fries
- Institute of Structural Analysis, Graz University of Technology, Austria
| | - Dominik Fleischmann
- 3D and Quantitative Imaging Laboratory, Department of Radiology, Stanford University, USA
| | | | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, USA
| | - Gerhard A. Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
2
|
Rothenberger SM, Zhang J, Markl M, Craig BA, Vlachos PP, Rayz VL. 4D flow MRI velocity uncertainty quantification. Magn Reson Med 2025; 93:397-410. [PMID: 39270010 DOI: 10.1002/mrm.30287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 07/27/2024] [Accepted: 08/20/2024] [Indexed: 09/15/2024]
Abstract
PURPOSE An automatic method is presented for estimating 4D flow MRI velocity measurement uncertainty in each voxel. The velocity distance (VD) metric, a statistical distance between the measured velocity and local error distribution, is introduced as a novel measure of 4D flow MRI velocity measurement quality. METHODS The method uses mass conservation to assess the local velocity error variance and the standardized difference of means (SDM) velocity to estimate the velocity error correlations. VD is evaluated as the Mahalanobis distance between the local velocity measurement and the local error distribution. The uncertainty model is validated synthetically and tested in vitro under different flow resolutions and noise levels. The VD's application is demonstrated on two in vivo thoracic vasculature 4D flow datasets. RESULTS Synthetic results show the proposed uncertainty quantification method is sensitive to aliased regions across various velocity-to-noise ratios and assesses velocity error correlations in four- and six-point acquisitions with correlation errors at or under 3.2%. In vitro results demonstrate the method's sensitivity to spatial resolution, venc settings, partial volume effects, and phase wrapping error sources. Applying VD to assess in vivo 4D flow MRI in the aorta demonstrates the expected increase in measured velocity quality with contrast administration and systolic flow. CONCLUSION The proposed 4D flow MRI uncertainty quantification method assesses velocity measurement error owing to sources including noise, intravoxel phase dispersion, and velocity aliasing. This method enables rigorous comparison of 4D flow MRI datasets obtained in longitudinal studies, across patient populations, and with different MRI systems.
Collapse
Affiliation(s)
- Sean M Rothenberger
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Jiacheng Zhang
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Michael Markl
- Department of Radiology at the Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Bruce A Craig
- Department of Statistics, Purdue University, West Lafayette, Indiana, USA
| | - Pavlos P Vlachos
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Vitaliy L Rayz
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
- School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA
| |
Collapse
|
3
|
Maimaiti P, Shu J, Miao T, Keqike N, Tuersun A, Ruiqi Yang, Wang N. Aerobic Training and Ointment Effect on range of motion, von Willebrand factor, vascular endothelial factor and Femoral Artery Hemodynamics in Joint Contracture: A Rat Model. Biol Res Nurs 2025; 27:17-27. [PMID: 39141917 DOI: 10.1177/10998004241274290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/16/2024]
Abstract
OBJECTIVE Using a rat model, we investigated the effect of multidisciplinary rehabilitation, including aerobic training and ointment, on the ROM, vWF, VEGF content, and femoral artery hemodynamics in rats with joint contracture. METHODS A total of 44 Wistar rats were divided into the normal control group (NC, eight rats) and the experimental group (EG). A joint contracture model was established for the rats in the EG group by an external fixator. After fixator removal, 32 rats are further divided into the MC, SC, RE, and SR groups (n = 8). Before and after the 42 day intervention, the ROM, vWF, VEGF, PS, ED, and RI were measured using X-ray imaging, ELISA, and color Doppler ultrasound, respectively. RESULTS After fixator removal, ROM for EG group was lower than that of the NC group (p < .01). After the intervention, ROM for the SR, RE, and SC groups was improved. The ROM for the SR group reached a similar value for NC group. vWF and VEGF levels in SR group were lower than in the MC, SC, and RE groups (p < .05), and had a similar value to the NC groups. PS value for SR and RE groups was higher than the MC and SC groups. The RI value for SR group was higher than that of NC and MC groups. CONCLUSION Multidisciplinary rehabilitation used in this study can treat joint contracture synergistically. It improves the ROM of the joint, reduces the content of vWF and VEGF, and improves the femoral artery hemodynamics.
Collapse
Affiliation(s)
| | - Jiaojiao Shu
- Nursing School, Xinjiang Medical University, Urumqi, China
| | - Tianyu Miao
- Nursing School, Xinjiang Medical University, Urumqi, China
| | - Nuerbiya Keqike
- Department of Nursing, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
| | | | - Ruiqi Yang
- Nursing School, Xinjiang Medical University, Urumqi, China
| | - Ningning Wang
- Nursing School, Xinjiang Medical University, Urumqi, China
| |
Collapse
|
4
|
Yin Z, Armour C, Kandail H, O'Regan DP, Bahrami T, Mirsadraee S, Pirola S, Xu XY. Fluid-structure interaction analysis of a healthy aortic valve and its surrounding haemodynamics. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3865. [PMID: 39209425 DOI: 10.1002/cnm.3865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 07/23/2024] [Accepted: 08/17/2024] [Indexed: 09/04/2024]
Abstract
The opening and closing dynamics of the aortic valve (AV) has a strong influence on haemodynamics in the aortic root, and both play a pivotal role in maintaining normal physiological functions of the valve. The aim of this study was to establish a subject-specific fluid-structure interaction (FSI) workflow capable of simulating the motion of a tricuspid healthy valve and the surrounding haemodynamics under physiologically realistic conditions. A subject-specific aortic root was reconstructed from magnetic resonance (MR) images acquired from a healthy volunteer, whilst the valve leaflets were built using a parametric model fitted to the subject-specific aortic root geometry. The material behaviour of the leaflets was described using the isotropic hyperelastic Ogden model, and subject-specific boundary conditions were derived from 4D-flow MR imaging (4D-MRI). Strongly coupled FSI simulations were performed using a finite volume-based boundary conforming method implemented in FlowVision. Our FSI model was able to simulate the opening and closing of the AV throughout the entire cardiac cycle. Comparisons of simulation results with 4D-MRI showed a good agreement in key haemodynamic parameters, with stroke volume differing by 7.5% and the maximum jet velocity differing by less than 1%. Detailed analysis of wall shear stress (WSS) on the leaflets revealed much higher WSS on the ventricular side than the aortic side and different spatial patterns amongst the three leaflets.
Collapse
Affiliation(s)
- Zhongjie Yin
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Chlöe Armour
- Department of Chemical Engineering, Imperial College London, London, UK
- National Heart and Lung Institute, Imperial College London, London, UK
| | | | - Declan P O'Regan
- Laboratory of Medical Sciences, Imperial College London, London, UK
| | - Toufan Bahrami
- National Heart and Lung Institute, Imperial College London, London, UK
- Department of Cardiothoracic Surgery, Royal Brompton and Harefield Hospitals NHS Trust, London, UK
| | - Saeed Mirsadraee
- National Heart and Lung Institute, Imperial College London, London, UK
- Department of Radiology, Royal Brompton and Harefield Hospitals NHS Trust, London, UK
| | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, UK
- Department of BioMechanical Engineering, TU Delft, Delft, The Netherlands
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| |
Collapse
|
5
|
Forneris A, Hassanabad AF, Appoo JJ, Di Martino ES. Predicting Aneurysmal Degeneration in Uncomplicated Residual Type B Aortic Dissection. Bioengineering (Basel) 2024; 11:690. [PMID: 39061772 PMCID: PMC11274148 DOI: 10.3390/bioengineering11070690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 06/18/2024] [Accepted: 06/19/2024] [Indexed: 07/28/2024] Open
Abstract
The formation of an aneurysm in the false lumen (FL) is a long-term complication in a significant percentage of type B aortic dissection (AD) patients. The ability to predict which patients are likely to progress to aneurysm formation is key to justifying the risks of interventional therapy. The investigation of patient-specific hemodynamics has the potential to enable a patient-tailored approach to improve prognosis by guiding disease management for type B dissection. CFD-derived hemodynamic descriptors and geometric features were used to retrospectively assess individual aortas for a population of residual type B AD patients and analyze correlations with known outcomes (i.e., rapid aortic growth, death). The results highlight great variability in flow patterns and hemodynamic descriptors. A rapid aortic expansion was found to be associated with a larger FL. Time-averaged wall shear stress at the tear region emerged as a possible indicator of the dynamics of flow exchange between lumens and its effect on the evolution of individual aortas. High FL flow rate and tortuosity were associated with adverse outcomes suggesting a role as indicators of risk. AD induces complex changes in vessel geometry and hemodynamics. The reported findings emphasize the need for a patient-tailored approach when evaluating uncomplicated type B AD patients and show the potential of CFD-derived hemodynamics to complement anatomical assessment and help disease management.
Collapse
Affiliation(s)
- Arianna Forneris
- Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada;
- R&D Department, ViTAA Medical Solutions, Montreal, QC H2K 1M6, Canada
| | - Ali F. Hassanabad
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.F.H.); (J.J.A.)
| | - Jehangir J. Appoo
- Section of Cardiac Surgery, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, Calgary, AB T2N 1N4, Canada; (A.F.H.); (J.J.A.)
| | - Elena S. Di Martino
- Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, AB T2N 1N4, Canada;
- R&D Department, ViTAA Medical Solutions, Montreal, QC H2K 1M6, Canada
| |
Collapse
|
6
|
Daneker M, Cai S, Qian Y, Myzelev E, Kumbhat A, Li H, Lu L. Transfer learning on physics-informed neural networks for tracking the hemodynamics in the evolving false lumen of dissected aorta. NEXUS (NEW YORK, N.Y.) 2024; 1:100016. [PMID: 39949515 PMCID: PMC11824901 DOI: 10.1016/j.ynexs.2024.100016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/16/2025]
Abstract
Aortic dissection is a life-threatening event that is responsible for significant morbidity and mortality in individuals ranging in age from children to older adults. A better understanding of the complex hemodynamic environment inside the aorta enables clinicians to assess patient-specific risk of complications and administer timely interventions. In this study, we propose to develop and validate a new computational framework, warm-start physics-informed neural networks (WS-PINNs), to address the limitations of the current approaches in analyzing the hemodynamics inside the false lumen (FL) of type B aortic dissection vessels reconstructed from apolipoprotein null mice infused with AngII, thereby significantly reducing the amount of required measurement data and eliminating the dependency of predictions on the accuracy and availability of the inflow/outflow boundary conditions. Specifically, we demonstrate that the WS-PINN models allow us to focus on assessing the 3D flow field inside FL without modeling the true lumen and various branched vessels. Furthermore, we investigate the impact of the spatial and temporal resolutions of MRI data on the prediction accuracy of the PINN model, which can guide the data acquisition to reduce time and financial costs. Finally, we consider the use of transfer learning to provide faster results when looking at similar but new geometries. Our results indicate that the proposed framework can enhance the capacity of hemodynamic analysis in vessels with aortic dissections, with the promise of eventually leading to improved prognostic ability and understanding of the development of aneurysms.
Collapse
Affiliation(s)
- Mitchell Daneker
- Department of Statistics and Data Science, Yale University, New Haven, CT 06511, USA
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
- These authors contributed equally
| | - Shengze Cai
- Institute of Cyber-System & Control, College of Control Science & Engineering, Zhejiang University, Hangzhou 310058, China
- These authors contributed equally
| | - Ying Qian
- School of Chemical, Materials, and Biomedical Engineering, University of Georgia, Athens, GA 30602, USA
| | - Eric Myzelev
- Department of Mathematics, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Arsh Kumbhat
- Department of Mathematics, ETH Zurich, 8092 Zurich, Switzerland
| | - He Li
- School of Chemical, Materials, and Biomedical Engineering, University of Georgia, Athens, GA 30602, USA
| | - Lu Lu
- Department of Statistics and Data Science, Yale University, New Haven, CT 06511, USA
- Wu Tsai Institute, Yale University, New Haven, CT 06510, USA
- Lead contact
| |
Collapse
|
7
|
Girardin L, Stokes C, Thet MS, Oo AY, Balabani S, Díaz-Zuccarini V. Patient-Specific Haemodynamic Analysis of Virtual Grafting Strategies in Type-B Aortic Dissection: Impact of Compliance Mismatch. Cardiovasc Eng Technol 2024; 15:290-304. [PMID: 38438692 PMCID: PMC11239731 DOI: 10.1007/s13239-024-00713-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 01/02/2024] [Indexed: 03/06/2024]
Abstract
INTRODUCTION Compliance mismatch between the aortic wall and Dacron Grafts is a clinical problem concerning aortic haemodynamics and morphological degeneration. The aortic stiffness introduced by grafts can lead to an increased left ventricular (LV) afterload. This study quantifies the impact of compliance mismatch by virtually testing different Type-B aortic dissection (TBAD) surgical grafting strategies in patient-specific, compliant computational fluid dynamics (CFD) simulations. MATERIALS AND METHODS A post-operative case of TBAD was segmented from computed tomography angiography data. Three virtual surgeries were generated using different grafts; two additional cases with compliant grafts were assessed. Compliant CFD simulations were performed using a patient-specific inlet flow rate and three-element Windkessel outlet boundary conditions informed by 2D-Flow MRI data. The wall compliance was calibrated using Cine-MRI images. Pressure, wall shear stress (WSS) indices and energy loss (EL) were computed. RESULTS Increased aortic stiffness and longer grafts increased aortic pressure and EL. Implementing a compliant graft matching the aortic compliance of the patient reduced the pulse pressure by 11% and EL by 4%. The endothelial cell activation potential (ECAP) differed the most within the aneurysm, where the maximum percentage difference between the reference case and the mid (MDA) and complete (CDA) descending aorta replacements increased by 16% and 20%, respectively. CONCLUSION This study suggests that by minimising graft length and matching its compliance to the native aorta whilst aligning with surgical requirements, the risk of LV hypertrophy may be reduced. This provides evidence that compliance-matching grafts may enhance patient outcomes.
Collapse
Affiliation(s)
- Louis Girardin
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley Street, London, W1W 7TS, UK
| | - Catriona Stokes
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley Street, London, W1W 7TS, UK
| | - Myat Soe Thet
- Department of Cardiothoracic Surgery, St Bartholomew's Hospital, West Smithfield, London, EC1A 7BE, UK
| | - Aung Ye Oo
- Department of Cardiothoracic Surgery, St Bartholomew's Hospital, West Smithfield, London, EC1A 7BE, UK
| | - Stavroula Balabani
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley Street, London, W1W 7TS, UK
| | - Vanessa Díaz-Zuccarini
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE, UK.
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley Street, London, W1W 7TS, UK.
| |
Collapse
|
8
|
Keramati H, Birgersson E, Kim S, Leo HL. A Monte Carlo Sensitivity Analysis for a Dimensionally Reduced-Order Model of the Aortic Dissection. Cardiovasc Eng Technol 2024; 15:333-345. [PMID: 38381368 DOI: 10.1007/s13239-024-00718-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 01/11/2024] [Indexed: 02/22/2024]
Abstract
PURPOSE Aortic dissection is associated with a high mortality rate. Although computational approaches have shed light on many aspects of the disease, a sensitivity analysis is required to determine the significance of different factors. Because of its complex geometry and high computational expense, the three-dimensional (3D) fluid-structure interaction (FSI) simulation is not a suitable approach for sensitivity analysis. METHODS We performed a Monte Carlo simulation (MCS) to investigate the sensitivity of hemodynamic quantities to the lumped parameters of our zero-dimensional (0D) model with numerically calculated lumped parameters. We performed local and global analyses on the effect of the model parameters on important hemodynamic quantities. RESULTS The MCS showed that a larger lumped resistance value for the false lumen and the tears result in a higher retrograde flow rate in the false lumen (the coefficient of variation,c v , i = 0.0183 , the sensitivityS X i σ = 0.54 , Spearman's coefficient,ρ s = 0.464 ). For the intraluminal pressure, our results show a significant role in the resistance and inertance of the true lumen (the coefficient of variation,c v , i = 0.0640 , the sensitivityS X i σ = 0.85 , and Spearman's coefficient,ρ s = 0.855 for the inertance of the true lumen). CONCLUSION This study highlights the necessity of comparing the results of the local and global sensitivity analyses to understand the significance of multiple lumped parameters. Because of the efficiency of the method, our approach is potentially useful to investigate and analyze medical planning.
Collapse
Affiliation(s)
- Hamed Keramati
- Integrative Sciences and Engineering Programme (ISEP), National University of Singapore, Singapore, Singapore
- Department of Biomedical Engineering, National University of Singapore, Singapore, 117576, Singapore
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Erik Birgersson
- Department of Mechanical Engineering, National University of Singapore, Singapore, 117575, Singapore
| | - Sangho Kim
- Integrative Sciences and Engineering Programme (ISEP), National University of Singapore, Singapore, Singapore
- Department of Biomedical Engineering, National University of Singapore, Singapore, 117576, Singapore
| | - Hwa Liang Leo
- Integrative Sciences and Engineering Programme (ISEP), National University of Singapore, Singapore, Singapore.
- Department of Biomedical Engineering, National University of Singapore, Singapore, 117576, Singapore.
| |
Collapse
|
9
|
Gheysen L, Maes L, Caenen A, Segers P, Peirlinck M, Famaey N. Uncertainty quantification of the wall thickness and stiffness in an idealized dissected aorta. J Mech Behav Biomed Mater 2024; 151:106370. [PMID: 38224645 DOI: 10.1016/j.jmbbm.2024.106370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 12/21/2023] [Accepted: 01/01/2024] [Indexed: 01/17/2024]
Abstract
Personalized treatment informed by computational models has the potential to markedly improve the outcome for patients with a type B aortic dissection. However, existing computational models of dissected walls significantly simplify the characteristic false lumen, tears and/or material behavior. Moreover, the patient-specific wall thickness and stiffness cannot be accurately captured non-invasively in clinical practice, which inevitably leads to assumptions in these wall models. It is important to evaluate the impact of the corresponding uncertainty on the predicted wall deformations and stress, which are both key outcome indicators for treatment optimization. Therefore, a physiology-inspired finite element framework was proposed to model the wall deformation and stress of a type B aortic dissection at diastolic and systolic pressure. Based on this framework, 300 finite element analyses, sampled with a Latin hypercube, were performed to assess the global uncertainty, introduced by 4 uncertain wall thickness and stiffness input parameters, on 4 displacement and stress output parameters. The specific impact of each input parameter was estimated using Gaussian process regression, as surrogate model of the finite element framework, and a δ moment-independent analysis. The global uncertainty analysis indicated minor differences between the uncertainty at diastolic and systolic pressure. For all output parameters, the 4th quartile contained the major fraction of the uncertainty. The parameter-specific uncertainty analysis elucidated that the material stiffness and relative thickness of the dissected membrane were the respective main determinants of the wall deformation and stress. The uncertainty analysis provides insight into the effect of uncertain wall thickness and stiffness parameters on the predicted deformation and stress. Moreover, it emphasizes the need for probabilistic rather than deterministic predictions for clinical decision making in aortic dissections.
Collapse
Affiliation(s)
- Lise Gheysen
- Institute for Biomedical Engineering and Technology, Electronics and Information Systems, Ghent University, Belgium.
| | - Lauranne Maes
- Biomechanics Section, Mechanical Engineering, KU Leuven, Belgium
| | - Annette Caenen
- Institute for Biomedical Engineering and Technology, Electronics and Information Systems, Ghent University, Belgium; Cardiovascular Imaging and Dynamics, Department of Cardiovascular Sciences, KU Leuven, Belgium
| | - Patrick Segers
- Institute for Biomedical Engineering and Technology, Electronics and Information Systems, Ghent University, Belgium
| | - Mathias Peirlinck
- Department of BioMechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, the Netherlands
| | - Nele Famaey
- Biomechanics Section, Mechanical Engineering, KU Leuven, Belgium
| |
Collapse
|
10
|
Zimmermann J, Bäumler K, Loecher M, Cork TE, Marsden AL, Ennis DB, Fleischmann D. Hemodynamic effects of entry and exit tear size in aortic dissection evaluated with in vitro magnetic resonance imaging and fluid-structure interaction simulation. Sci Rep 2023; 13:22557. [PMID: 38110526 PMCID: PMC10728172 DOI: 10.1038/s41598-023-49942-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 12/13/2023] [Indexed: 12/20/2023] Open
Abstract
Understanding the complex interplay between morphologic and hemodynamic features in aortic dissection is critical for risk stratification and for the development of individualized therapy. This work evaluates the effects of entry and exit tear size on the hemodynamics in type B aortic dissection by comparing fluid-structure interaction (FSI) simulations with in vitro 4D-flow magnetic resonance imaging (MRI). A baseline patient-specific 3D-printed model and two variants with modified tear size (smaller entry tear, smaller exit tear) were embedded into a flow- and pressure-controlled setup to perform MRI as well as 12-point catheter-based pressure measurements. The same models defined the wall and fluid domains for FSI simulations, for which boundary conditions were matched with measured data. Results showed exceptionally well matched complex flow patterns between 4D-flow MRI and FSI simulations. Compared to the baseline model, false lumen flow volume decreased with either a smaller entry tear (- 17.8 and - 18.5%, for FSI simulation and 4D-flow MRI, respectively) or smaller exit tear (- 16.0 and - 17.3%). True to false lumen pressure difference (initially 11.0 and 7.9 mmHg, for FSI simulation and catheter-based pressure measurements, respectively) increased with a smaller entry tear (28.9 and 14.6 mmHg), and became negative with a smaller exit tear (- 20.6 and - 13.2 mmHg). This work establishes quantitative and qualitative effects of entry or exit tear size on hemodynamics in aortic dissection, with particularly notable impact observed on FL pressurization. FSI simulations demonstrate acceptable qualitative and quantitative agreement with flow imaging, supporting its deployment in clinical studies.
Collapse
Affiliation(s)
| | - Kathrin Bäumler
- Department of Radiology, Stanford University, Stanford, CA, USA.
| | - Michael Loecher
- Department of Radiology, Stanford University, Stanford, CA, USA
- Division of Radiology, Veterans Affairs Health Care System, Palo Alto, CA, USA
| | - Tyler E Cork
- Department of Radiology, Stanford University, Stanford, CA, USA
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Alison L Marsden
- Department of Bioengineering, Stanford University, Stanford, CA, USA
- Department of Pediatrics, Stanford University, Stanford, CA, USA
| | - Daniel B Ennis
- Department of Radiology, Stanford University, Stanford, CA, USA
- Division of Radiology, Veterans Affairs Health Care System, Palo Alto, CA, USA
| | | |
Collapse
|
11
|
Pirola S, Pirola S, Mastroiacovo G, Bonomi A, Manchester EL, Fisichella SM, Maragna R, Baggiano A, Mushtaq S, Muscogiuri G, Guglielmo M, Yun Xu X, Pontone G, Polvani G. Does the AVNeo valve reduce wall stress on the aortic wall? A cardiac magnetic resonance analysis with 4D-flow for the evaluation of aortic valve replacement with the Ozaki technique. Eur J Cardiothorac Surg 2023; 64:ezad299. [PMID: 37656941 DOI: 10.1093/ejcts/ezad299] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 08/15/2023] [Accepted: 08/31/2023] [Indexed: 09/03/2023] Open
Abstract
OBJECTIVES Aortic valve neocuspidalization aims to replace the 3 aortic cusps with autologous pericardium pre-treated with glutaraldehyde, and it is a surgical alternative to the classical aortic valve replacement (AVR). Image-based patient-specific computational fluid dynamics allows the derivation of shear stress on the aortic wall [wall shear stress (WSS)]. Previous studies support a potential link between increased WSS and histological alterations of the aortic wall. The aim of this study is to compare the WSS of the ascending aorta in patients undergoing aortic valve neocuspidalization versus AVR with biological prostheses. METHODS This is a prospective nonrandomized clinical trial. Each patient underwent a 4D-flow cardiac magnetic resonance scan after surgery, which informed patient-specific computational fluid dynamics models to evaluate WSS at the ascending aortic wall. The adjusted variables were calculated by summing the residuals obtained from a multivariate linear model (with ejection fraction and left ventricle outflow tract-aorta angle as covariates) to the mean of the variables. RESULTS Ten patients treated with aortic valve neocuspidalization were enrolled and compared with 10 AVR patients. The aortic valve neocuspidalization group showed a significantly lower WSS in the outer curvature segments of the proximal and distal ascending aorta as compared to AVR patients (P = 0.0179 and 0.0412, respectively). WSS levels remained significantly lower along the outer curvature of the proximal aorta in the aortic valve neocuspidalization population, even after adjusting the WSS for the ejection fraction and the left ventricle outflow tract-aorta angle [2.44 Pa (2.17-3.01) vs 1.94 Pa (1.72-2.01), P = 0.02]. CONCLUSIONS Aortic valve neocuspidalization hemodynamical features are potentially associated with a lower WSS in the ascending aorta as compared to commercially available bioprosthetic valves.
Collapse
Affiliation(s)
- Sergio Pirola
- Department of Cardiovascular Surgery, IRCCS Centro Cardiologico Monzino, Milan, Italy
| | - Selene Pirola
- Institute of Clinical Sciences, Imperial College London, London, UK
- Department of BioMechanical Engineering, TU Delft, Delft, Netherlands
| | - Giorgio Mastroiacovo
- Department of Cardiovascular Surgery, IRCCS Centro Cardiologico Monzino, Milan, Italy
| | - Alice Bonomi
- Department of Biostatistics, IRCCS Centro Cardiologico Monzino, Milan, Italy
| | | | | | - Riccardo Maragna
- Department of Cardiac imaging, IRCCS Centro Cardiologico Monzino, Milan, Italy
| | - Andrea Baggiano
- Department of Cardiac imaging, IRCCS Centro Cardiologico Monzino, Milan, Italy
- Department of Cardiovascular Sciences and Community Health, University of Milan, Milan, Italy
| | | | - Giuseppe Muscogiuri
- Department of Radiology, IRCCS Istituto Auxologico Italiano, San Luca Hospital, Milan, Italy
| | - Marco Guglielmo
- Department of Cardiology, Division of Heart and Lungs, Utrecht University, Utrecht University Medical Center, Utrecht, Netherlands
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, UK
| | - Gianluca Pontone
- Department of Cardiac imaging, IRCCS Centro Cardiologico Monzino, Milan, Italy
| | - Gianluca Polvani
- Department of Cardiovascular Surgery, IRCCS Centro Cardiologico Monzino, Milan, Italy
- Department of Surgical and Dental Biomedical Sciences, University of Milan, Italy
| |
Collapse
|
12
|
Guo B, Akhtar R, Liu H, Yan C, Guo D, Patterson B, Fu W. Staged surgically created type B aortic dissection model with endovascular reintervention for different morphological features. INTERDISCIPLINARY CARDIOVASCULAR AND THORACIC SURGERY 2023; 37:ivad133. [PMID: 37561091 PMCID: PMC10656095 DOI: 10.1093/icvts/ivad133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 05/28/2023] [Accepted: 08/09/2023] [Indexed: 08/11/2023]
Abstract
OBJECTIVES Understanding morphology and how this relates to treatment strategy is critical for achieving remodelling in aortic dissection. A controllable and reproducible large animal model is required for investigating new therapeutic devices and interventions. METHODS Our experimental protocol involved the development of surgically created type B aortic dissection (TBAD) and endovascular reintervention-induced TBAD porcine models. The sample was randomly divided into 2 groups: 1 underwent a secondary tear creation (STC) procedure and the other underwent a false lumen extension (FLE) procedure. Anatomical features were observed at 1 and 3 months, and 2 animals in each group were euthanized at 3 months after the procedures. The aorta and main branches were harvested en bloc, cross-sectioned and prepared for histological examination. RESULTS All surgically created TBAD models were successfully generated, and no unintended complications occurred. The endovascular reintervention-induced TBAD model was successfully created in 11 of 12 animals, with 6 in the STC group and 5 in the FLE group. In the STC group, the intraoperative mean diameter of the new secondary tear was 7.23 mm, and a slight increase was observed at first 30 days (P = 0.0026). In the FLE group, the intraoperative new propagation length was (235.80 ± 84.94) mm. The FL propagation length at the 1-month follow-up was significantly longer than that measured intraoperatively (P = 0.0362). Histological evaluation demonstrated that the elastic fibres in the media layer of the aortic wall were disrupted and appeared to be significantly stretched on the adventitial side of the false lumen. CONCLUSIONS Our endovascular reintervention is a reliable, minimally invasive approach for producing specific TBAD models with different morphologies.
Collapse
Affiliation(s)
- Baolei Guo
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
- Fudan Zhangjiang Institute, Shanghai, China
| | - Riaz Akhtar
- Department of Mechanical, Materials and Aerospace Engineering, School of Engineering, University of Liverpool, Liverpool, UK
| | - Haofei Liu
- Department of Mechanics, Tianjin University, Tianjin, China
| | - Cheng Yan
- National Clinical Research Center for Interventional Medicine, Shanghai, China
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Daqiao Guo
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Benjamin Patterson
- Department of Vascular Surgery, University Hospital Southampton, Southampton, UK
| | - Weiguo Fu
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
- National Clinical Research Center for Interventional Medicine, Shanghai, China
| |
Collapse
|
13
|
Garg I, Grist TM, Nagpal P. MR Angiography for Aortic Diseases. Magn Reson Imaging Clin N Am 2023; 31:373-394. [PMID: 37414467 DOI: 10.1016/j.mric.2023.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
Aortic pathologic conditions represent diverse disorders, including aortic aneurysm, acute aortic syndrome, traumatic aortic injury, and atherosclerosis. Given the nonspecific clinical features, noninvasive imaging is critical in screening, diagnosis, management, and posttherapeutic surveillance. Of the commonly used imaging modalities, including ultrasound, computed tomography, and MR imaging, the final choice often depends on a combination of factors: acuity of clinical presentation, suspected underlying diagnosis, and institutional practice. Further research is needed to identify the potential clinical role and define appropriate use criteria for advanced MR applications such as four-dimenional flow to manage patients with aortic pathologic conditions.
Collapse
Affiliation(s)
- Ishan Garg
- Department of Internal Medicine, University of New Mexico Health Sciences Center, 1 University Of New Mexico, Albuquerque, NM 87131, USA
| | - Thomas M Grist
- Department of Radiology, University of Wisconsin-Madison, E3/366 Clinical Science Center 600 Highland Avenue Madison, WI 53792, USA
| | - Prashant Nagpal
- Cardiovascular and Thoracic Radiology, University of Wisconsin School of Medicine and Public Health, E3/366 Clinical Science Center, 600 Highland Avenue, Madison, WI 53792, USA.
| |
Collapse
|
14
|
Wang K, Armour CH, Ma T, Dong Z, Xu XY. Hemodynamic parameters impact the stability of distal stent graft-induced new entry. Sci Rep 2023; 13:12123. [PMID: 37495611 PMCID: PMC10372056 DOI: 10.1038/s41598-023-39130-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 07/19/2023] [Indexed: 07/28/2023] Open
Abstract
Stent graft-induced new entry tear (SINE) is a serious complication in aortic dissection patients caused by the stent-graft itself after thoracic endovascular aortic repair (TEVAR). The stability of SINE is a key indicator for the need and timing of reinterventions. This study aimed to understand the role of hemodynamics in SINE stability by means of computational fluid dynamics (CFD) analysis based on patient-specific anatomical information. Four patients treated with TEVAR who developed a distal SINE (dSINE) were included; two patients had a stable dSINE and two patients experienced expansion of the dSINE upon follow-up examinations. CFD simulations were performed on geometries reconstructed from computed tomography scans acquired upon early detection of dSINE in these patients. Computational results showed that stable dSINEs presented larger regions with low time-averaged wall shear stress (TAWSS) and high relative residence time (RRT), and partial thrombosis was observed at subsequent follow-ups. Furthermore, significant systolic antegrade flow was observed in the unstable dSINE which also had a larger retrograde flow fraction (RFF) on the SINE plane. In conclusion, this pilot study suggested that high RRT and low TAWSS may indicate stable dSINE by promoting thrombosis, whereas larger RFF and antegrade flows inside dSINE might be associated with its expansion.
Collapse
Affiliation(s)
- Kaihong Wang
- Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Chlӧe H Armour
- Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Tao Ma
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Zhihui Dong
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
| |
Collapse
|
15
|
Salmasi MY, Pirola S, Mahuttanatan S, Fisichella SM, Sengupta S, Jarral OA, Oo A, O'Regan D, Xu XY, Athanasiou T. Geometry and flow in ascending aortic aneurysms are influenced by left ventricular outflow tract orientation: Detecting increased wall shear stress on the outer curve of proximal aortic aneurysms. J Thorac Cardiovasc Surg 2023; 166:11-21.e1. [PMID: 34217540 DOI: 10.1016/j.jtcvs.2021.06.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 05/31/2021] [Accepted: 06/02/2021] [Indexed: 12/27/2022]
Abstract
BACKGROUND The geometrical characterization of ascending thoracic aortic aneurysms in clinical practice is limited to diameter measurements. Despite growing interest in hemodynamic assessment, its relationship with ascending thoracic aortic aneurysm pathogenesis is poorly understood. This study examines the relationship between geometry of the ventriculo-aortic junction and blood flow patterns in ascending thoracic aortic aneurysm disease. METHODS Thirty-three patients with ascending thoracic aortic aneurysms (exclusions: bicuspid aortic valves, connective tissue disease) underwent 4-dimensional flow magnetic resonance imaging. After image segmentation, geometrical parameters were measured, including aortic curvature, tortuosity, length, and diameter. A unique angular measurement made by the trajectory of the left ventricular outflow tract axis and the proximal aorta was also conducted. Velocity profiles were quantitatively and qualitatively analyzed. In addition, 11 patients (33%) underwent wall shear stress mapping of the ascending thoracic aortic aneurysm region using computational fluid dynamics simulation. RESULTS Greater left ventricular outflow tract aortic angles were associated with larger aortic diameters at the levels of the sinus (coefficient = 0.387, P = .014) and ascending aorta (coefficient = 0.284, P = .031). Patients with left ventricular outflow tract aortic angles greater than 60° had marked asymmetric flow acceleration on the outer curvature in the proximal aorta, ascertained from 4-dimensional flow analysis. For patients undergoing computational fluid dynamics assessment, regression analysis found that higher left ventricular outflow tract aortic angles were associated with significantly higher wall shear stress values in the outer curve of the aorta (coefficient 0.07, 95% confidence interval 0.04-0.11, P = .002): Angles greater than 50° yielded time-averaged wall shear stress values greater than 2.5 Pa, exhibiting a linear relationship. CONCLUSIONS Our findings strengthen the hypothesis of flow-mediated ascending thoracic aortic aneurysm disease progression and that left ventricular outflow tract aortic angle may be a predictor of disease severity.
Collapse
Affiliation(s)
- M Yousuf Salmasi
- Department of Surgery, Imperial College London, London, United Kingdom.
| | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Suchaya Mahuttanatan
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Serena M Fisichella
- Department of Chemical Engineering, Imperial College London, London, United Kingdom; Politecnico di Milano, Milan, Italy
| | - Sampad Sengupta
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Omar A Jarral
- Department of Surgery, Imperial College London, London, United Kingdom
| | - Aung Oo
- Barts Heart Centre, London, United Kingdom
| | - Declan O'Regan
- London Institute of Medical Sciences, Imperial College London, London, United Kingdom
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Thanos Athanasiou
- Department of Surgery, Imperial College London, London, United Kingdom
| |
Collapse
|
16
|
Motoki K, Zhu Y, Mirsadraee S, Rosendahl U, Pepper J, Xu XY. A computational study of the effects of size, location, and number of tears on haemodynamics in surgically repaired type A aortic dissection. Front Cardiovasc Med 2023; 10:1215720. [PMID: 37388636 PMCID: PMC10301719 DOI: 10.3389/fcvm.2023.1215720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 06/05/2023] [Indexed: 07/01/2023] Open
Abstract
Objective This study aimed to comprehensively examine the roles of size, location, and number of tears in the progression of surgically repaired type A aortic dissection (TAAD) by assessing haemodynamic changes through patient-specific computational fluid dynamic (CFD) simulations. Methods Two patient-specific TAAD geometries with replaced ascending aorta were reconstructed based upon computed 15 tomography (CT) scans, after which 10 hypothetical models (5 per patient) with different tear configurations were artificially created. CFD simulations were performed on all the models under physiologically realistic boundary conditions. Results Our simulation results showed that increasing either the size or number of the re-entry tears reduced the luminal pressure difference (LPD) and maximum time-averaged wall shear stress (TAWSS), as well as areas exposed to abnormally high or low TAWSS values. Models with a large re-entry tear outperformed the others by reducing the maximum LPD by 1.88 mmHg and 7.39 mmHg, for patients 1 and 2, respectively. Moreover, proximally located re-entry tears in the descending aorta were more effective at reducing LPD than distal re-entry tears. Discussion These computational results indicate that the presence of a relatively large re-entry tear in the proximal descending aorta might help stabilize post-surgery aortic growth. This finding has important implications for the management and risk stratification of surgically repaired TAAD patients. Nevertheless, further validation in a large patient cohort is needed.
Collapse
Affiliation(s)
- Kyosuke Motoki
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Yu Zhu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Saeed Mirsadraee
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Radiology, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - Ulrich Rosendahl
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - John Pepper
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| |
Collapse
|
17
|
Saitta S, Maga L, Armour C, Votta E, O'Regan DP, Salmasi MY, Athanasiou T, Weinsaft JW, Xu XY, Pirola S, Redaelli A. Data-driven generation of 4D velocity profiles in the aneurysmal ascending aorta. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 233:107468. [PMID: 36921465 DOI: 10.1016/j.cmpb.2023.107468] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 02/15/2023] [Accepted: 03/05/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND AND OBJECTIVE Numerical simulations of blood flow are a valuable tool to investigate the pathophysiology of ascending thoratic aortic aneurysms (ATAA). To accurately reproduce in vivo hemodynamics, computational fluid dynamics (CFD) models must employ realistic inflow boundary conditions (BCs). However, the limited availability of in vivo velocity measurements, still makes researchers resort to idealized BCs. The aim of this study was to generate and thoroughly characterize a large dataset of synthetic 4D aortic velocity profiles sampled on a 2D cross-section along the ascending aorta with features similar to clinical cohorts of patients with ATAA. METHODS Time-resolved 3D phase contrast magnetic resonance (4D flow MRI) scans of 30 subjects with ATAA were processed through in-house code to extract anatomically consistent cross-sectional planes along the ascending aorta, ensuring spatial alignment among all planes and interpolating all velocity fields to a reference configuration. Velocity profiles of the clinical cohort were extensively characterized by computing flow morphology descriptors of both spatial and temporal features. By exploiting principal component analysis (PCA), a statistical shape model (SSM) of 4D aortic velocity profiles was built and a dataset of 437 synthetic cases with realistic properties was generated. RESULTS Comparison between clinical and synthetic datasets showed that the synthetic data presented similar characteristics as the clinical population in terms of key morphological parameters. The average velocity profile qualitatively resembled a parabolic-shaped profile, but was quantitatively characterized by more complex flow patterns which an idealized profile would not replicate. Statistically significant correlations were found between PCA principal modes of variation and flow descriptors. CONCLUSIONS We built a data-driven generative model of 4D aortic inlet velocity profiles, suitable to be used in computational studies of blood flow. The proposed software system also allows to map any of the generated velocity profiles to the inlet plane of any virtual subject given its coordinate set.
Collapse
Affiliation(s)
- Simone Saitta
- Department of Information, Electronics and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Ludovica Maga
- Department of Information, Electronics and Bioengineering, Politecnico di Milano, Milan, Italy; Department of Chemical Engineering, Imperial College London, London, UK
| | - Chloe Armour
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Emiliano Votta
- Department of Information, Electronics and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Declan P O'Regan
- MRC London Institute of Medical Sciences, Imperial College London, London, United Kingdom
| | - M Yousuf Salmasi
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Thanos Athanasiou
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Jonathan W Weinsaft
- Department of Medicine (Cardiology), Weill Cornell College, New York, NY, USA
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, UK; Department of BioMechanical Engineering, 3mE Faculty, Delft University of Technology, Delft, Netherlands.
| | - Alberto Redaelli
- Department of Information, Electronics and Bioengineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
18
|
Zhu Y, Xu XY, Rosendahl U, Pepper J, Mirsadraee S. Advanced risk prediction for aortic dissection patients using imaging-based computational flow analysis. Clin Radiol 2023; 78:e155-e165. [PMID: 36610929 DOI: 10.1016/j.crad.2022.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 11/28/2022] [Accepted: 12/02/2022] [Indexed: 12/24/2022]
Abstract
Patients with either a repaired or medically managed aortic dissection have varying degrees of risk of developing late complications. High-risk patients would benefit from earlier intervention to improve their long-term survival. Currently serial imaging is used for risk stratification, which is not always reliable. On the other hand, understanding aortic haemodynamics within a dissection is essential to fully evaluate the disease and predict how it may progress. In recent decades, computational fluid dynamics (CFD) has been extensively applied to simulate complex haemodynamics within aortic diseases, and more recently, four-dimensional (4D)-flow magnetic resonance imaging (MRI) techniques have been developed for in vivo haemodynamic measurement. This paper presents a comprehensive review on the application of image-based CFD simulations and 4D-flow MRI analysis for risk prediction in aortic dissection. The key steps involved in patient-specific CFD analyses are demonstrated. Finally, we propose a workflow incorporating computational modelling for personalised assessment to aid in risk stratification and treatment decision-making.
Collapse
Affiliation(s)
- Y Zhu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - X Y Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - U Rosendahl
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, UK; National Heart and Lung Institute, Imperial College London, London, UK
| | - J Pepper
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, UK; National Heart and Lung Institute, Imperial College London, London, UK
| | - S Mirsadraee
- National Heart and Lung Institute, Imperial College London, London, UK; Department of Radiology, Royal Brompton and Harefield Hospitals, London, UK.
| |
Collapse
|
19
|
Lim E, Shi Y, Leo HL, Al Abed A. Editorial: Data assimilation in cardiovascular medicine: Merging experimental measurements with physics-based computational models. Front Physiol 2023; 14:1153861. [PMID: 36846318 PMCID: PMC9948236 DOI: 10.3389/fphys.2023.1153861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 02/01/2023] [Indexed: 02/11/2023] Open
Affiliation(s)
- E. Lim
- University of Malaya, Kuala Lumpur, Malaysia,*Correspondence: E. Lim,
| | - Y. Shi
- Shaanxi University of Chinese Medicine, Xianyang, Shaanxi, China
| | - H. L. Leo
- National University of Singapore, Singapore, Singapore
| | - A. Al Abed
- University of New South Wales, Kensington, NSW, Australia
| |
Collapse
|
20
|
Tricarico R, Berceli SA, Tran-Son-Tay R, He Y. Non-invasive estimation of the parameters of a three-element windkessel model of aortic arch arteries in patients undergoing thoracic endovascular aortic repair. Front Bioeng Biotechnol 2023; 11:1127855. [PMID: 36926690 PMCID: PMC10011467 DOI: 10.3389/fbioe.2023.1127855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 02/17/2023] [Indexed: 03/08/2023] Open
Abstract
Background: Image-based computational hemodynamic modeling and simulations are important for personalized diagnosis and treatment of cardiovascular diseases. However, the required patient-specific boundary conditions are often not available and need to be estimated. Methods: We propose a pipeline for estimating the parameters of the popular three-element Windkessel (WK3) models (a proximal resistor in series with a parallel combination of a distal resistor and a capacitor) of the aortic arch arteries in patients receiving thoracic endovascular aortic repair of aneurysms. Pre-operative and post-operative 1-week duplex ultrasound scans were performed to obtain blood flow rates, and intra-operative pressure measurements were also performed invasively using a pressure transducer pre- and post-stent graft deployment in arch arteries. The patient-specific WK3 model parameters were derived from the flow rate and pressure waveforms using an optimization algorithm reducing the error between simulated and measured pressure data. The resistors were normalized by total resistance, and the capacitor was normalized by total resistance and heart rate. The normalized WK3 parameters can be combined with readily available vessel diameter, brachial blood pressure, and heart rate data to estimate WK3 parameters of other patients non-invasively. Results: Ten patients were studied. The medians (interquartile range) of the normalized proximal resistor, distal resistor, and capacitor parameters are 0.10 (0.07-0.15), 0.90 (0.84-0.93), and 0.46 (0.33-0.58), respectively, for common carotid artery; 0.03 (0.02-0.04), 0.97 (0.96-0.98), and 1.91 (1.63-2.26) for subclavian artery; 0.18 (0.08-0.41), 0.82 (0.59-0.92), and 0.47 (0.32-0.85) for vertebral artery. The estimated pressure showed fairly high tolerance to patient-specific inlet flow rate waveforms using the WK3 parameters estimated from the medians of the normalized parameters. Conclusion: When patient-specific outflow boundary conditions are not available, our proposed pipeline can be used to estimate the WK3 parameters of arch arteries.
Collapse
Affiliation(s)
- Rosamaria Tricarico
- Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States
| | - Scott A Berceli
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, University of Florida, Gainesville, FL, United States.,North Florida/South Georgia Veterans Health System, Gainesville, FL, United States
| | - Roger Tran-Son-Tay
- Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States.,Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, United States
| | - Yong He
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, University of Florida, Gainesville, FL, United States
| |
Collapse
|
21
|
Wang Q, Guo X, Brooks M, Chuen J, Poon EKW, Ooi A, Lim RP. MRI in CFD for chronic type B aortic dissection: Ready for prime time? Comput Biol Med 2022; 150:106138. [PMID: 36191393 DOI: 10.1016/j.compbiomed.2022.106138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/31/2022] [Accepted: 09/18/2022] [Indexed: 11/24/2022]
Abstract
OBJECTIVES Better tools are needed for risk assessment of Type B aortic dissection (TBAD) to determine optimal treatment for patients with uncomplicated disease. Magnetic resonance imaging (MRI) has the potential to inform computational fluid dynamics (CFD) simulations for TBAD by providing individualised quantification of haemodynamic parameters, for assessment of complication risks. This systematic review aims to present an overview of MRI applications for CFD studies of TBAD. METHODS Following PRISMA guidelines, a search in Medline, Embase, and the Scopus Library identified 136 potentially relevant articles. Studies were included if they used MRI to inform CFD simulation in TBAD. RESULTS There were 20 articles meeting the inclusion criteria. 19 studies used phase contrast MRI (PC-MRI) to provide data for CFD flow boundary conditions. In 12 studies, CFD haemodynamic parameter results were validated against PC-MRI. In eight studies, geometric models were developed from MR angiography. In three studies, aortic wall or intimal flap motion data were derived from PC/cine MRI. CONCLUSIONS MRI provides complementary patient-specific information in CFD haemodynamic studies for TBAD that can be used for personalised care. MRI provides structural, dynamic and flow data to inform CFD for pre-treatment planning, potentially advancing its integration into clinical decision-making. The use of MRI to inform CFD in TBAD surgical planning is promising, however further validation and larger cohort studies are required.
Collapse
Affiliation(s)
- Qingdi Wang
- Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia.
| | - Xiaojing Guo
- Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia
| | - Mark Brooks
- Department of Radiology, Austin Health, Heidelberg, VIC, 3084, Australia; School of Medicine, Deakin University, Melbourne, Australia
| | - Jason Chuen
- Department of Surgery, Austin Health, Heidelberg, VIC, 3084, Australia; Department of Surgery, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia
| | - Eric K W Poon
- Department of Medicine, St Vincent's Hospital, Melbourne Medical School, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia
| | - Andrew Ooi
- Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia
| | - Ruth P Lim
- Department of Radiology, Austin Health, Heidelberg, VIC, 3084, Australia; Department of Surgery, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia; Department of Radiology, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Melbourne, VIC, 3010, Australia
| |
Collapse
|
22
|
Jafarinia A, Armour CH, Gibbs RGJ, Xu XY, Hochrainer T. Shear-driven modelling of thrombus formation in type B aortic dissection. Front Bioeng Biotechnol 2022; 10:1033450. [PMID: 36394040 PMCID: PMC9643857 DOI: 10.3389/fbioe.2022.1033450] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 10/13/2022] [Indexed: 11/27/2022] Open
Abstract
Background: Type B aortic dissection (TBAD) is a dangerous pathological condition with a high mortality rate. TBAD is initiated by an intimal tear that allows blood to flow between the aortic wall layers, causing them to separate. As a result, alongside the original aorta (true lumen), a false lumen (FL) develops. TBAD compromises the whole cardiovascular system, in the worst case resulting in complete aortic rupture. Clinical studies have shown that dilation and rupture of the FL are related to the failure of the FL to thrombose. Complete FL thrombosis has been found to improve the clinical outcomes of patients with chronic TBAD and is the desired outcome of any treatment. Partial FL thrombosis has been associated with late dissection-related deaths and the requirement for re-intervention, thus the level of FL thrombosis is dominant in classifying the risk of TBAD patients. Therefore, it is important to investigate and understand under which conditions complete thrombosis of the FL occurs. Method: Local FL hemodynamics play an essential role in thrombus formation and growth. In this study, we developed a simplified phenomenological model to predict FL thrombosis in TBAD under physiological flow conditions. Based on an existing shear-driven thrombosis model, a comprehensive model reduction study was performed to improve computational efficiency. The reduced model has been implemented in Ansys CFX and applied to a TBAD case following thoracic endovascular aortic repair (TEVAR) to test the model. Predicted thrombus formation based on post-TEVAR geometry at 1-month was compared to actual thrombus formation observed on a 3-year follow-up CT scan. Results: The predicted FL status is in excellent agreement with the 3-year follow-up scan, both in terms of thrombus location and total volume, thus validating the new model. The computational cost of the new model is significantly lower than the previous thrombus model, with an approximate 65% reduction in computational time. Such improvement means the new model is a significant step towards clinical applicability. Conclusion: The thrombosis model developed in this study is accurate and efficient at predicting FL thrombosis based on patient-specific data, and may assist clinicians in choosing individualized treatments in the future.
Collapse
Affiliation(s)
- Alireza Jafarinia
- Institute of Strength of Materials, Graz University of Technology, Graz, Austria
- *Correspondence: Alireza Jafarinia, ; Xiao Yun Xu,
| | - Chlöe H. Armour
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Richard G. J. Gibbs
- Regional Vascular Unit, St Mary’s Hospital, Imperial College Healthcare National Health Service Trust, Imperial College London, London, United Kingdom
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
- *Correspondence: Alireza Jafarinia, ; Xiao Yun Xu,
| | - Thomas Hochrainer
- Institute of Strength of Materials, Graz University of Technology, Graz, Austria
| |
Collapse
|
23
|
Liu D, Wang X, Zhao D, Sun Z, Biekan J, Wen Z, Xu L, Liu J. Influence of MRI-based boundary conditions on type B aortic dissection simulations in false lumen with or without abdominal aorta involvement. Front Physiol 2022; 13:977275. [PMID: 36160847 PMCID: PMC9490059 DOI: 10.3389/fphys.2022.977275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 08/15/2022] [Indexed: 11/13/2022] Open
Abstract
Most computational hemodynamic studies of aortic dissections rely on idealized or general boundary conditions. However, numerical simulations that ignore the characteristics of the abdominal branch arteries may not be conducive to accurately observing the hemodynamic changes below the branch arteries. In the present study, two men (M-I and M-II) with type B aortic dissection (TBAD) underwent arterial-phase computed tomography angiography and four-dimensional flow magnetic resonance imaging (MRI) before and after thoracic endovascular aortic repair (TEVAR). The finite element method was used to simulate the computational fluid dynamic parameters of TBAD [false lumen (FL) with or without visceral artery involvement] under MRI-specific and three idealized boundary conditions in one cardiac cycle. Compared to the results of zero pressure and outflow boundary conditions, the simulations with MRI boundary conditions were closer to the initial MRI data. The pressure difference between true lumen and FL after TEVAR under the other three boundary conditions was lower than that of the MRI-specific results. The results of the outflow boundary conditions could not characterize the effect of the increased wall pressure near the left renal artery caused by the impact of Tear-1, which raised concerns about the distal organ and limb perfused by FL. After TEVAR, the flow velocity and wall pressure in the FL and the distribution areas of high time average wall shear stress and oscillating shear index were reduced. The difference between the calculation results for different boundary conditions was lower in M-II, wherein FL did not involve the abdominal aorta branches than in M-I. The boundary conditions of the abdominal branch arteries from MRI data might be valuable in elucidating the hemodynamic changes of the descending aorta in TBAD patients before and after treatment, especially those with FL involving the branch arteries.
Collapse
Affiliation(s)
- Dongting Liu
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Xuan Wang
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China
| | - Dongliang Zhao
- Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China
| | - Zhonghua Sun
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, WA, Australia
- *Correspondence: Jiayi Liu, ; Zhonghua Sun,
| | | | - Zhaoying Wen
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Lei Xu
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Jiayi Liu
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
- *Correspondence: Jiayi Liu, ; Zhonghua Sun,
| |
Collapse
|
24
|
Cherry M, Khatir Z, Khan A, Bissell M. The impact of 4D-Flow MRI spatial resolution on patient-specific CFD simulations of the thoracic aorta. Sci Rep 2022; 12:15128. [PMID: 36068322 PMCID: PMC9448751 DOI: 10.1038/s41598-022-19347-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Accepted: 08/29/2022] [Indexed: 11/29/2022] Open
Abstract
Magnetic Resonance Imaging (MRI) is considered the gold standard of medical imaging technologies as it allows for accurate imaging of blood vessels. 4-Dimensional Flow Magnetic Resonance Imaging (4D-Flow MRI) is built on conventional MRI, and provides flow data in the three vector directions and a time resolved magnitude data set. As such it can be used to retrospectively calculate haemodynamic parameters of interest, such as Wall Shear Stress (WSS). However, multiple studies have indicated that a significant limitation of the imaging technique is the spatiotemporal resolution that is currently available. Recent advances have proposed and successfully integrated 4D-Flow MRI imaging techniques with Computational Fluid Dynamics (CFD) to produce patient-specific simulations that have the potential to aid in treatments,surgical decision making, and risk stratification. However, the consequences of using insufficient 4D-Flow MRI spatial resolutions on any patient-specific CFD simulations is currently unclear, despite being a recognised limitation. The research presented in this study aims to quantify the inaccuracies in patient-specific 4D-Flow MRI based CFD simulations that can be attributed to insufficient spatial resolutions when acquiring 4D-Flow MRI data. For this research, a patient has undergone four 4D-Flow MRI scans acquired at various isotropic spatial resolutions and patient-specific CFD simulations have subsequently been run using geometry and velocity data produced from each scan. It was found that compared to CFD simulations based on a \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$1.5\,{\text {mm}} \times 1.5\,{\text {mm}} \times 1.5\,{\text {mm}}$$\end{document}1.5mm×1.5mm×1.5mm, using a spatial resolution of \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$4\,{\text {mm}} \times 4\,{\text {mm}} \times 4\,{\text {mm}}$$\end{document}4mm×4mm×4mm substantially underestimated the maximum velocity magnitude at peak systole by \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$110.55\%$$\end{document}110.55%. The impacts of 4D-Flow MRI spatial resolution on WSS calculated from CFD simulations have been investigated and it has been shown that WSS is underestimated in CFD simulations that are based on a coarse 4D-Flow MRI spatial resolution. The authors have concluded that a minimum 4D-Flow MRI spatial resolution of \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$1.5\,{\text {mm}} \times 1.5\,{\text {mm}} \times 1.5\,{\text {mm}}$$\end{document}1.5mm×1.5mm×1.5mm must be used when acquiring 4D-Flow MRI data to perform patient-specific CFD simulations. A coarser spatial resolution will produce substantial differences within the flow field and geometry.
Collapse
Affiliation(s)
- Molly Cherry
- CDT in Fluid Dynamics, School of Computing, University of Leeds, Leeds, LS2 9JT, UK.
| | - Zinedine Khatir
- School of Engineering and the Built Environment, Birmingham City University, Birmingham, B4 7XG, UK.,School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT, UK
| | - Amirul Khan
- School of Civil Engineering, University of Leeds, Leeds, LS2 9JT, UK
| | | |
Collapse
|
25
|
Zhang X, Chen D, Wu M, Dong H, Wan Z, Jia H, Liang S, Shao J, Zheng J, Xu S, Xiong J, Guo W. Functional Evaluation of Embedded Modular Single-Branched Stent Graft: Application to Type B Aortic Dissection With Aberrant Right Subclavian Artery. Front Cardiovasc Med 2022; 9:869505. [PMID: 35586645 PMCID: PMC9108238 DOI: 10.3389/fcvm.2022.869505] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 04/12/2022] [Indexed: 11/13/2022] Open
Abstract
Background Endovascular repair of type B aortic dissection (TBAD) with aberrant right subclavian artery (ARSA) is challenging due to anatomical complexity. The embedded modular single-branched stent graft (EMSBSG) could solve this problem. However, the hemodynamic efficacy of this innovative technique has not been fully assessed. This study aimed to propose morphometric and functional indicators to quantify the outcomes of EMSBSG in treating TBAD with ARSA. Material and Methods A patient who had TBAD with ARSA underwent EMSBSG implantation was admitted. Computational fluid dynamics (CFD) and three-dimensional structural analyses were conducted based on CTA datasets before the operation (Pre-1) and at 4 and 25 days after EMSBSG implantation (Post-1 and Post-2). Quantitative and qualitative functional analyses were conducted via pressure-, velocity- and wall shear stress (WSS) -based parameters, such as the luminal pressure difference (LPD), total energy loss, and flow distribution ratio. By precisely registering the aortas at the three time points, parameter variations in the EMSBSG region were also computed to investigate the prognostic improvement after EMSBSG implantation. Results The first balance point of LPD distally shifted to the abdominal aorta in Post-1 by a distance of 20.172 cm, and shifted out of the dissected region in Post-2, indicating positive pressure recovery post EMSBSG. The flow distribution ratios of all aortic arch branches increased after EMSBSG implantation. A positive normal deformation index in the EMSBSG region confirmed true lumen expansion; dominant ARN (area ratio of negative value) of pressure and WSS-based parameters indicated an improved prognosis from Post-1 to Post-2. Conclusions The short-term results of EMSBSG in treating TBAD with ARSA proved to be promising, especially in EMSBSG region. Comprehensive evaluation could provide new insight into the therapy of TBAD with ARSA. Thus, it might guide the further management of complex aortic arch lesions.
Collapse
|
26
|
Li Z, Xu H, Armour CH, Guo Y, Xiong J, Xu X, Chen D. The Necessity to Seal the Re-Entry Tears of Aortic Dissection After TEVAR: A Hemodynamic Indicator. Front Bioeng Biotechnol 2022; 10:831903. [PMID: 35433660 PMCID: PMC9009393 DOI: 10.3389/fbioe.2022.831903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 01/11/2022] [Indexed: 11/13/2022] Open
Abstract
Thoracic endovascular aortic repair (TEVAR) is a common treatment for Stanford type B aortic dissection (TBAD). However, re-entry tears might be found distal to the stented region which transports blood between the true and false lumens. Sealing the re-entry tears, especially for the thoracic tears, could further reduce blood perfusion to the false lumen; however, it might also bring risks by re-intervention or surgery. Wise determination of the necessity to seal the re-entry tears is needed. In this study, patient-specific models of TBAD were reconstructed, and the modified models were established by virtually excluding the thoracic re-entries. Computational hemodynamics was investigated, and the variation of the functional index and first balance position (FBP) of the luminal pressure difference, due to the sealing of the re-entries, was reported. The results showed that the direction of the net flow through the unstented thoracic re-entries varied among cases. Excluding the re-entries with the net flow toward the false lumen may induce the FBP moving distally and the relative particle residence time increasing in the false lumen. This study preliminarily demonstrated that the hemodynamic status of the re-entry tears might serve as an indicator to the necessity of sealing. By quantifying the through-tear flow exchange and shift of FBP, one can predict the hemodynamic benefit by sealing the thoracic re-entries and thus wisely determine the necessity of further interventional management.
Collapse
Affiliation(s)
- Zhenfeng Li
- School of Life Science, Beijing Institute of Technology, Beijing, China
- Wenzhou Safety (Emergency) Institute of Tianjin University, Zhejiang, China
| | - Huanming Xu
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Chlöe Harriet Armour
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Yuze Guo
- School of Biomedical Engineering, University of Sydney, Sydney, NSW, Australia
| | - Jiang Xiong
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China
- *Correspondence: Jiang Xiong, ; Xiaoyun Xu,
| | - Xiaoyun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
- *Correspondence: Jiang Xiong, ; Xiaoyun Xu,
| | - Duanduan Chen
- School of Life Science, Beijing Institute of Technology, Beijing, China
- Wenzhou Safety (Emergency) Institute of Tianjin University, Zhejiang, China
| |
Collapse
|
27
|
Morris L, Tierney P, Hynes N, Sultan S. An in vitro Assessment of the Haemodynamic Features Occurring Within the True and False Lumens Separated by a Dissection Flap for a Patient-Specific Type B Aortic Dissection. Front Cardiovasc Med 2022; 9:797829. [PMID: 35369331 PMCID: PMC8968342 DOI: 10.3389/fcvm.2022.797829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 02/15/2022] [Indexed: 11/14/2022] Open
Abstract
One of the highest mortality rates of cardiovascular diseases is aortic dissections with challenging treatment options. Currently, less study has been conducted in developing in vitro patient-specific Type B aortic dissection models, which mimic physiological flow conditions along the true and false lumens separated by a dissection flap with multiple entry and exit tears. A patient-specific Stanford Type B aortic dissection scan was replicated by an in-house manufactured automatic injection moulding system and a novel modelling technique for creating the ascending aorta, aortic arch, and descending aorta incorporating arterial branching, the true/false lumens, and dissection flap with entry and exit intimal tears. The physiological flowrates and pressure values were monitored, which identified jet stream fluid flows entering and exiting the dissection tears. Pressure in the aorta’s true lumen region was controlled at 125/85 mmHg for systolic and diastolic values. Pressure values were obtained in eight sections along the false lumen using a pressure transducer. The true lumen systolic pressure varied from 122 to 128 mmHg along the length. Flow patterns were monitored by ultrasound along 12 sections. Detailed images obtained from the ultrasound transducer probe showed varied flow patterns with one or multiple jet steam vortices along the aorta model. The dissection flap movement was assessed at four sections of the patient-specific aorta model. The displacement values of the flap varied from 0.5 to 3 mm along the model. This model provides a unique insight into aortic dissection flow patterns and pressure distributions. This dissection phantom model can be used to assess various treatment options based on the surgical, endovascular, or hybrid techniques.
Collapse
Affiliation(s)
- Liam Morris
- Galway-Mayo Institute of Technology, Galway, Ireland
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
- Medical and Engineering Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
- Lero – Science Foundation Ireland Research Centre for Software, Galway-Mayo Institute of Technology, Galway, Ireland
- *Correspondence: Liam Morris,
| | - Paul Tierney
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
- Medical and Engineering Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
| | - Niamh Hynes
- CÚRAM, National University of Ireland, Galway, Ireland
| | - Sherif Sultan
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University College Hospital Galway, Galway, Ireland
- Department of Vascular and Endovascular Surgery, Galway Clinic, Royal College of Surgeons in Ireland, Doughiska, Ireland
| |
Collapse
|
28
|
Takahashi K, Sekine T, Ando T, Ishii Y, Kumita S. Utility of 4D Flow MRI in Thoracic Aortic Diseases: A Literature Review of Clinical Applications and Current Evidence. Magn Reson Med Sci 2022; 21:327-339. [PMID: 34497166 PMCID: PMC9680552 DOI: 10.2463/mrms.rev.2021-0046] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 07/17/2021] [Indexed: 11/09/2022] Open
Abstract
Despite the recent technical developments, surgery on the thoracic aorta remains challenging and is associated with significant mortality and morbidity. Decisions about when and if to operate are based on a balance between surgical risk and the hazard of aortic rupture. These decisions are sometimes difficult in elective cases of thoracic aortic diseases, including aneurysms and dissections. Abnormal wall stress derived from flow alterations influences disease progression. Therefore, a better understanding of the complex hemodynamic environment inside the aortic lumen will facilitate patient-specific risk assessments of complications, which enable clinicians to provide timely prophylactic interventions. Time-resolved 3D phase-contrast (4D flow) MRI has many advantages for the in vivo assessment of flow dynamics. Recent developments in 4D flow imaging techniques has led to significant advances in our understanding of physiological flow dynamics in healthy subjects and patients with thoracic aortic diseases. In this clinically focused review of thoracic aortic diseases, we demonstrate the clinical advances acquired with 4D flow MRI from published studies. We provide a systematic overview of key evidences and considerations regarding normal thoracic aortas, thoracic aortic aneurysms, aortic dissections, and thoracic aortas with prosthetic graft replacement.
Collapse
Affiliation(s)
| | - Tetsuro Sekine
- Department of Radiology, Nippon Medical School Musashi Kosugi Hospital, Kawasaki, Kanagawa, Japan
| | - Takahiro Ando
- Department of Radiology, Nippon Medical School, Tokyo, Japan
| | - Yosuke Ishii
- Department of Cardiovascular Surgery, Nippon Medical School, Tokyo, Japan
| | | |
Collapse
|
29
|
Zhu Y, Xu XY, Rosendahl U, Pepper J, Mirsadraee S. Prediction of aortic dilatation in surgically repaired type A dissection: A longitudinal study using computational fluid dynamics. JTCVS OPEN 2022; 9:11-27. [PMID: 36003481 PMCID: PMC9390758 DOI: 10.1016/j.xjon.2022.01.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 01/13/2022] [Indexed: 05/11/2023]
Abstract
OBJECTIVE To examine the role of a key hemodynamic parameter, namely the true and false lumen pressure difference, to predict progressive aortic dilatation following type A aortic dissection (TAAD) repair. METHODS Four patients with surgically repaired TAAD with multiple follow-up computed tomography angiography scans (4-5 scans per patient; N = 18) were included. Through-plane diameter of the residual native thoracic aorta was measured in various aortic segments during the follow up period (mean follow-up: 49.6 ± 31.2 months). Computational flow analysis was performed to estimate true and false lumen pressure difference at the same locations and the correlation with aortic size change was studied using a linear mixed effects model. RESULTS Greater pressure difference between the true and false lumen was consistent with greater aortic diameter expansion during the follow up period (linear mixed effects analysis; coefficient, 0.26; 95% confidence interval, 0.15-0.37; P < .001). Based on our limited data points, a pressure difference higher than 5 mm Hg might cause unstable aortic growth. CONCLUSIONS Computational fluid dynamic assessment of standard aortic computed tomography angiography offers a noninvasive technique that predicts the risk of aortic dilatation following TAAD. The technique may be used to plan closer observation or intervention in high-risk patients.
Collapse
Affiliation(s)
- Yu Zhu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Ulrich Rosendahl
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - John Pepper
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - Saeed Mirsadraee
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Radiology, Royal Brompton and Harefield Hospitals, London, United Kingdom
- Address for reprints: Saeed Mirsadraee, MD, PhD, Department of Radiology, Royal Brompton Hospital, Sydney St, Chelsea, London SW3 6NP, United Kingdom.
| |
Collapse
|
30
|
Saitta S, Guo B, Pirola S, Menichini C, Guo D, Shan Y, Dong Z, Xu XY, Fu W. Qualitative and Quantitative Assessments of Blood Flow on Tears in Type B Aortic Dissection With Different Morphologies. Front Bioeng Biotechnol 2021; 9:742985. [PMID: 34692660 PMCID: PMC8531216 DOI: 10.3389/fbioe.2021.742985] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Accepted: 09/21/2021] [Indexed: 12/17/2022] Open
Abstract
Objective: The interactions between aortic morphology and hemodynamics play a key role in determining type B aortic dissection (TBAD) progression and remodeling. The study aimed to provide qualitative and quantitative hemodynamic assessment in four different TBAD morphologies based on 4D flow MRI analysis. Materials and Methods: Four patients with different TBAD morphologies underwent CT and 4D flow MRI scans. Qualitative blood flow evaluation was performed by visualizing velocity streamlines and flow directionality near the tears. Quantitative analysis included flow rate, velocity and reverse flow index (RFI) measurements. Statistical analysis was performed to evaluate hemodynamic differences between the true lumen (TL) and false lumen (FL) of patients. Results: Qualitative analysis revealed blood flow splitting near the primary entry tears (PETs), often causing the formation of vortices in the FL. All patients exhibited clear hemodynamic differences between TL and FL, with the TL generally showing higher velocities and flow rates, and lower RFIs. Average velocity magnitude measurements were significantly different for Patient 1 (t = 5.61, p = 0.001), Patient 2 (t = 3.09, p = 0.02) and Patient 4 (t = 2.81, p = 0.03). At follow-up, Patient three suffered from left renal ischemia because of FL collapse. This patient presented a complex morphology with two FLs and marked flow differences between TL and FLs. In Patient 4, left renal artery malperfusion was observed at the 32-months follow-up, due to FL thrombosis growing after PET repair. Conclusion: The study demonstrates the clinical feasibility of using 4D flow MRI in the context of TBAD. Detailed patient-specific hemodynamics assessment before treatment may provide useful insights to better understand this pathology in the future.
Collapse
Affiliation(s)
- Simone Saitta
- Department of Chemical Engineering, Imperial College London, London, United Kingdom.,Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Baolei Guo
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
| | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Claudia Menichini
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Daqiao Guo
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
| | - Yan Shan
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Zhihui Dong
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Weiguo Fu
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
| |
Collapse
|
31
|
Brown SR, Still SA, Eudailey KW, Beck AW, Gunn AJ. Acute traumatic injury of the aorta: presentation, diagnosis, and treatment. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1193. [PMID: 34430634 PMCID: PMC8350653 DOI: 10.21037/atm-20-3172] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 07/24/2020] [Indexed: 12/11/2022]
Abstract
Despite advances in detection and treatment, acute traumatic aortic injury (ATAI) is associated with high rates of morbidity and mortality. Both physical and hemodynamic forces have been postulated as mechanisms of aortic injury during a traumatic event. For patients who survive the initial injury, rapid detection is critical for diagnosis and procedural planning, which requires a thorough knowledge of both its clinical presentation and the available diagnostic imaging modalities. Radiography, computed tomography (CT), and magnetic resonance imaging (MRI) can each have a role in the diagnosis of ATAI. After stabilization of the patient, the management of ATAI is guided by the severity of injury. Appropriately selected patients with low grade injuries may be managed non-operatively. When treatment is required, there are both open surgical and endovascular options. In current practice, endovascular approaches with stent-graft placement are preferred due to their high clinical success and low rates of complications. Complications from endograft placement can include: endoleak, endograft collapse, infection, endograft failure, and endograft migration. Open surgical repair is now reserved for patients with unfavorable anatomy for endovascular therapies. This review provides a comprehensive overview of ATAI including its epidemiology and demographics, mechanisms of injury, clinical and radiographic diagnosis, treatment options, and post-therapeutic follow-up.
Collapse
Affiliation(s)
- S Rodes Brown
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Sasha A Still
- Division of Cardiothoracic Surgery, Department of Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Kyle W Eudailey
- Division of Cardiothoracic Surgery, Department of Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Adam W Beck
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Andrew J Gunn
- Division of Interventional Radiology, Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
32
|
Manchester EL, Pirola S, Salmasi MY, O'Regan DP, Athanasiou T, Xu XY. Analysis of Turbulence Effects in a Patient-Specific Aorta with Aortic Valve Stenosis. Cardiovasc Eng Technol 2021; 12:438-453. [PMID: 33829405 PMCID: PMC8354935 DOI: 10.1007/s13239-021-00536-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/18/2021] [Indexed: 10/26/2022]
Abstract
Blood flow in the aorta is often assumed laminar, however aortic valve pathologies may induce transition to turbulence and our understanding of turbulence effects is incomplete. The aim of the study was to provide a detailed analysis of turbulence effects in aortic valve stenosis (AVS). METHODS Large-eddy simulation (LES) of flow through a patient-specific aorta with AVS was conducted. Magnetic resonance imaging (MRI) was performed and used for geometric reconstruction and patient-specific boundary conditions. Computed velocity field was compared with 4D flow MRI to check qualitative and quantitative consistency. The effect of turbulence was evaluated in terms of fluctuating kinetic energy, turbulence-related wall shear stress (WSS) and energy loss. RESULTS Our analysis suggested that turbulence was induced by a combination of a high velocity jet impinging on the arterial wall and a dilated ascending aorta which provided sufficient space for turbulence to develop. Turbulent WSS contributed to 40% of the total WSS in the ascending aorta and 38% in the entire aorta. Viscous and turbulent irreversible energy losses accounted for 3.9 and 2.7% of the total stroke work, respectively. CONCLUSIONS This study demonstrates the importance of turbulence in assessing aortic haemodynamics in a patient with AVS. Neglecting the turbulent contribution to WSS could potentially result in a significant underestimation of the total WSS. Further work is warranted to extend the analysis to more AVS cases and patients with other aortic valve diseases.
Collapse
Affiliation(s)
- Emily L Manchester
- Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Mohammad Yousuf Salmasi
- Department of Surgery and Cancer, St Mary's Hospital, Imperial College London, London, W2 1NY, UK
| | - Declan P O'Regan
- Hammersmith Hospital, MRC London Institute of Medical Sciences Imperial College London, London, W12 0HS, UK
| | - Thanos Athanasiou
- Department of Surgery and Cancer, St Mary's Hospital, Imperial College London, London, W2 1NY, UK
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
| |
Collapse
|
33
|
Zhu Y, Mirsadraee S, Asimakopoulos G, Gambaro A, Rosendahl U, Pepper J, Xu XY. Association of hemodynamic factors and progressive aortic dilatation following type A aortic dissection surgical repair. Sci Rep 2021; 11:11521. [PMID: 34075164 PMCID: PMC8169847 DOI: 10.1038/s41598-021-91079-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 05/13/2021] [Indexed: 12/21/2022] Open
Abstract
Type A aortic dissection (TAAD) involves the ascending aorta or the arch. Acute TAAD usually requires urgent replacement of the ascending aorta. However, a subset of these patients develops aortic rupture due to further dilatation of the residual dissected aorta. There is currently no reliable means to predict the risk of dilatation following TAAD repair. In this study, we performed a comprehensive morphological and hemodynamic analysis for patients with and without progressive aortic dilatation following surgical replacement of the ascending aorta. Patient-specific models of repaired TAAD were reconstructed from post-surgery computed tomography images for detailed computational fluid dynamic analysis. Geometric and hemodynamic parameters were evaluated and compared between patients with stable aortic diameters (N = 9) and those with aortic dilatation (N = 8). Our results showed that the number of re-entry tears and true/false lumen pressure difference were significantly different between the two groups. Patients with progressive aortic dilatation had higher luminal pressure difference (6.7 [4.6, 10.9] vs. 0.9 [0.5, 2.3] mmHg; P = 0.001) and fewer re-entry tears (1.5 [1, 2.8] vs. 5 [3.3, 7.5]; P = 0.02) compared to patients with stable aortic diameters, suggesting that these factors may serve as potential predictors of aneurysmal dilatation following surgical repair of TAAD.
Collapse
Affiliation(s)
- Yu Zhu
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Saeed Mirsadraee
- Department of Radiology, Royal Brompton and Harefield Hospitals NHS Trust, London, SW3 6NP, UK
| | - George Asimakopoulos
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals NHS Trust, London, SW3 6NP, UK
| | - Alessia Gambaro
- Department of Cardiology, Royal Brompton and Harefield Hospitals NHS Trust, London, SW3 6NP, UK
| | - Ulrich Rosendahl
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals NHS Trust, London, SW3 6NP, UK
| | - John Pepper
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals NHS Trust, London, SW3 6NP, UK
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK.
| |
Collapse
|
34
|
Li Z, Liang S, Xu H, Zhu M, Mei Y, Xiong J, Chen D. Flow analysis of aortic dissection: comparison of inflow boundary conditions for computational models based on 4D PCMRI and Doppler ultrasound. Comput Methods Biomech Biomed Engin 2021; 24:1251-1262. [PMID: 33522843 DOI: 10.1080/10255842.2021.1876036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Computational hemodynamics quantifying the flow environment is an important tool in understanding aortic dissection. In this study, various inflow boundaries were applied on a patient-specific model and compared to the individualized velocimetry. The results indicated that the computations generally overestimated the flow volume and underestimated the wall shear stress. By quantifying the accuracy of the simulation results, two inflow settings were suggested. One was individualized, the PCMRI-extracted 4D flow information, and the other was averaged by healthy data, the ultrasound-extracted averaged flow waveform with parabolic velocity profile. This study might contribute to improving the precise computation of aortic dissection hemodynamics.
Collapse
Affiliation(s)
- Zhenfeng Li
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Shichao Liang
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Huanming Xu
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Minjia Zhu
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Yuqian Mei
- School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Jiang Xiong
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Duanduan Chen
- School of Life Science, Beijing Institute of Technology, Beijing, China
| |
Collapse
|
35
|
Coccarelli A, Saha S, Purushotham T, Arul Prakash K, Nithiarasu P. On the poro-elastic models for microvascular blood flow resistance: An in vitro validation. J Biomech 2021; 117:110241. [PMID: 33486261 DOI: 10.1016/j.jbiomech.2021.110241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 11/11/2020] [Accepted: 01/04/2021] [Indexed: 10/22/2022]
Abstract
Nowadays, adequate and accurate representation of the microvascular flow resistance constitutes one of the major challenges in computational haemodynamic studies. In this work, a theoretical, porous media framework, ultimately designed for representing downstream resistance, is presented and compared against an in vitro experimental results. The resistor consists of a poro-elastic tube, with either a constant or variable porosity profile in space. The underlying physics, characterizing the fluid flow through the porous media, is analysed by considering flow variables at different network locations. Backward reflections, originated in the reservoir of the in vitro model, are accounted for through a reflection coefficient imposed as an outflow network condition. The simulation results are in good agreement with the measurements for both the homogenous and heterogeneous porosity conditions. In addition, the comparison allows identification of the range of values representing experimental reservoir reflection coefficients. The pressure drops across the heterogeneous porous media increases with respect to the simpler configuration, whilst flow remains almost unchanged. The effect of some fluid network features, such as tube Young's modulus and fluid viscosity, on the theoretical results is also elucidated, providing a reference for the invitro and insilico simulation of different microvascular conditions.
Collapse
Affiliation(s)
- Alberto Coccarelli
- Biomedical Engineering Group, Zienkiewicz Centre for Computational Engineering, College of Engineering, Swansea University, UK
| | - Supratim Saha
- Department of Applied Mechanics, Indian Institute of Technology Madras, India
| | - Tanjeri Purushotham
- Department of Applied Mechanics, Indian Institute of Technology Madras, India
| | - K Arul Prakash
- Department of Applied Mechanics, Indian Institute of Technology Madras, India
| | - Perumal Nithiarasu
- Biomedical Engineering Group, Zienkiewicz Centre for Computational Engineering, College of Engineering, Swansea University, UK; VAJRA Adjunct Professor, Indian Institute of Technology Madras, India.
| |
Collapse
|
36
|
Salmasi MY, Pirola S, Sasidharan S, Fisichella SM, Redaelli A, Jarral OA, O'Regan DP, Oo AY, Moore JE, Xu XY, Athanasiou T. High Wall Shear Stress can Predict Wall Degradation in Ascending Aortic Aneurysms: An Integrated Biomechanics Study. Front Bioeng Biotechnol 2021; 9:750656. [PMID: 34733832 PMCID: PMC8558434 DOI: 10.3389/fbioe.2021.750656] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 09/24/2021] [Indexed: 01/16/2023] Open
Abstract
Background: Blood flow patterns can alter material properties of ascending thoracic aortic aneurysms (ATAA) via vascular wall remodeling. This study examines the relationship between wall shear stress (WSS) obtained from image-based computational modelling with tissue-derived mechanical and microstructural properties of the ATAA wall using segmental analysis. Methods: Ten patients undergoing surgery for ATAA were recruited. Exclusions: bicuspid aortopathy, connective tissue disease. All patients had pre-operative 4-dimensional flow magnetic resonance imaging (4D-MRI), allowing for patient-specific computational fluid dynamics (CFD) analysis and anatomically precise WSS mapping of ATAA regions (6-12 segments per patient). ATAA samples were obtained from surgery and subjected to region-specific tensile and peel testing (matched to WSS segments). Computational pathology was used to characterize elastin/collagen abundance and smooth muscle cell (SMC) count. Results: Elevated values of WSS were predictive of: reduced wall thickness [coef -0.0489, 95% CI (-0.0905, -0.00727), p = 0.022] and dissection energy function (longitudinal) [-15,0, 95% CI (-33.00, -2.98), p = 0.048]. High WSS values also predicted higher ultimate tensile strength [coef 0.136, 95% CI (0 0.001, 0.270), p = 0.048]. Additionally, elevated WSS also predicted a reduction in elastin levels [coef -0.276, 95% (CI -0.531, -0.020), p = 0.035] and lower SMC count ([oef -6.19, 95% CI (-11.41, -0.98), p = 0.021]. WSS was found to have no effect on collagen abundance or circumferential mechanical properties. Conclusions: Our study suggests an association between elevated WSS values and aortic wall degradation in ATAA disease. Further studies might help identify threshold values to predict acute aortic events.
Collapse
Affiliation(s)
- M Yousuf Salmasi
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Sumesh Sasidharan
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Serena M Fisichella
- Department of Chemical Engineering, Imperial College London, London, United Kingdom.,Politecnico di Milano, Milan, Italy
| | | | - Omar A Jarral
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Declan P O'Regan
- MRC London Institute of Medical Sciences, Imperial College London, London, United Kingdom
| | - Aung Ye Oo
- Barts Heart Centre, London, United Kingdom
| | - James E Moore
- Department of Bioengineering, Imperial College London, London, United Kingdom
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Thanos Athanasiou
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| |
Collapse
|
37
|
Bondesson J, Suh GY, Lundh T, Dake MD, Lee JT, Cheng CP. Quantification of true lumen helical morphology and chirality in type B aortic dissections. Am J Physiol Heart Circ Physiol 2020; 320:H901-H911. [PMID: 33382638 DOI: 10.1152/ajpheart.00778.2020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Chirality is a fundamental property in many biological systems. Motivated by previous observations of helical aortic blood flow, aortic tissue fibers, and propagation of aortic dissections, we introduce methods to characterize helical morphology of aortic dissections. After validation on computer-generated phantoms, the methods were applied to patients with type B dissection. For this cohort, there was a distinct bimodal distribution of helical propagation of the dissection with either achiral or exclusively right-handed chirality, with no intermediate cases or left-handed cases. This clear grouping indicates that dissection propagation favors these two modes, which is potentially due to the right-handedness of helical aortic blood flow and cell orientation. The characterization of dissection chirality and quantification of helical morphology advances our understanding of dissection pathology and lays a foundation for applications in clinical research and treatment practice. For example, the chirality and magnitude of helical metrics of dissections may indicate risk of dissection progression, help define treatment and surveillance strategies, and enable development of novel devices that account for various helical morphologies.NEW & NOTEWORTHY A novel definition of helical propagation of type B aortic dissections reveals a distinct bimodality, with the true lumen being either achiral (nonhelical) or exclusively right-handed. This right-handed chirality is consistent with anatomic and physiological phenomena such as right-handed twist during left ventricle contraction, helical blood flow, and tissue fiber direction. The helical character of aortic dissections may be useful for pathology research, diagnostics, treatment selection, therapeutic durability prediction, and aortic device design.
Collapse
Affiliation(s)
- Johan Bondesson
- Division of Dynamics, Chalmers University of Technology, Gothenburg, Sweden
| | - Ga-Young Suh
- Department of Biomedical Engineering, California State University, Long Beach, California.,Division of Vascular Surgery, Stanford University, Stanford, California
| | - Torbjörn Lundh
- Mathematical Sciences, Chalmers University of Technology and University of Gothenburg, Gothenburg, Sweden
| | - Michael D Dake
- Department of Surgery, University of Arizona, Tucson, Arizona
| | - Jason T Lee
- Division of Vascular Surgery, Stanford University, Stanford, California
| | | |
Collapse
|
38
|
Bonfanti M, Franzetti G, Homer-Vanniasinkam S, Díaz-Zuccarini V, Balabani S. A Combined In Vivo, In Vitro, In Silico Approach for Patient-Specific Haemodynamic Studies of Aortic Dissection. Ann Biomed Eng 2020; 48:2950-2964. [PMID: 32929558 PMCID: PMC7723947 DOI: 10.1007/s10439-020-02603-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 09/02/2020] [Indexed: 12/30/2022]
Abstract
The optimal treatment of Type-B aortic dissection (AD) is still a subject of debate, with up to 50% of the cases developing late-term complications requiring invasive intervention. A better understanding of the patient-specific haemodynamic features of AD can provide useful insights on disease progression and support clinical management. In this work, a novel in vitro and in silico framework to perform personalised studies of AD, informed by non-invasive clinical data, is presented. A Type-B AD was investigated in silico using computational fluid dynamics (CFD) and in vitro by means of a state-of-the-art mock circulatory loop and particle image velocimetry (PIV). Both models not only reproduced the anatomical features of the patient, but also imposed physiologically-accurate and personalised boundary conditions. Experimental flow rate and pressure waveforms, as well as detailed velocity fields acquired via PIV, are extensively compared against numerical predictions at different locations in the aorta, showing excellent agreement. This work demonstrates how experimental and numerical tools can be developed in synergy to accurately reproduce patient-specific AD blood flow. The combined platform presented herein constitutes a powerful tool for advanced haemodynamic studies for a range of vascular conditions, allowing not only the validation of CFD models, but also clinical decision support, surgical planning as well as medical device innovation.
Collapse
Affiliation(s)
- Mirko Bonfanti
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Department of Medical Physics and Biomedical Engineering, University College London, 43-45 Foley Street, London, W1W 7TS UK
| | - Gaia Franzetti
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE UK
| | - Shervanthi Homer-Vanniasinkam
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Department of Medical Physics and Biomedical Engineering, University College London, 43-45 Foley Street, London, W1W 7TS UK
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE UK
- Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds, LS1 3EX UK
| | - Vanessa Díaz-Zuccarini
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Department of Medical Physics and Biomedical Engineering, University College London, 43-45 Foley Street, London, W1W 7TS UK
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE UK
| | - Stavroula Balabani
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE UK
| |
Collapse
|
39
|
Effect of Geometric Accuracy at the Proximal Landing Zone on Simulation Results for Thoracic Endovascular Repair Patients. Cardiovasc Eng Technol 2020; 11:679-688. [PMID: 33145725 DOI: 10.1007/s13239-020-00498-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 10/20/2020] [Indexed: 02/05/2023]
Abstract
PURPOSE Existing hemodynamic studies on aortic dissection after thoracic endovascular aortic repair (TEVAR) apply geometric simplifications. This study aims to evaluate the necessity of more accurate geometries at the proximal landing zone in computational fluid dynamic (CFD) studies. METHODS Three patient-specific 3D aortic dissection models with different geometric accuracies at the proximal landing zone were manually fabricated for CFD simulations: (i) model 1 without the stent graft (SG), (ii) model 2 with the metal stent, and (iii) model 3 with the SG. The flow distribution, flow pattern, and wall shear stress (WSS)-related indicators in these three models were compared. RESULTS The flow distributions were quite similar for the three models, with a maximum absolute difference of 0.27% at the left suclavian artery (LSA) between models 1 and 3 because of partial coverage. A more chaotic flow pattern was observed at the proximal landing zone in model 3, with significant regional differences in the WSS-related indicator distributions. The upstream and downstream WSS-related indicator distributions were quite similar for the three models. CONCLUSIONS The flow pattern and hemodynamic parameter distributions were affected by the geometric accuracy only in a small region near the proximal landing zone. The flow split was hardly affected by the LSA partial coverage, indicating that the coverage may have slight effects on short-term blood perfusion. However, this conclusion needs to be verified in future studies with larger sample sizes.
Collapse
|
40
|
The effect of the entry and re-entry size in the aortic dissection: a two-way fluid-structure interaction simulation. Biomech Model Mechanobiol 2020; 19:2643-2656. [PMID: 32621161 DOI: 10.1007/s10237-020-01361-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Accepted: 06/20/2020] [Indexed: 12/16/2022]
Abstract
Aortic dissection (AD) is one of the most catastrophic cardiovascular diseases. AD occurs when a layer inside the aorta is disrupted and gives rise to the formation of a true lumen and a false lumen. These lumens can be connected through tears in the intimal flap which are known as entries. Despite being known for about two centuries, the effects of many factors on the morbidity and mortality of this disease are still unknown. As the blood interaction with the aorta is crucial in the severity and the progression of the aortic dissection, a biomechanical approach is chosen to investigate the influence of different morphologies on the severity of this disease. Using the finite element method (FEM) and the fluid-structure interaction (FSI) approach, we have evaluated the blood flow characteristics along the diseased aorta, in conjunction with the deformation of the aortic wall. In this study, an idealized geometry of a dissected descending aorta (type B) with two entries has been studied. The values for the diameter of the entry tear were chosen to be 5 mm and 10 mm. Therefore, a total of four conditions were investigated. According to our results, the retrograde flow through the proximal tear is dependent on the size of the distal re-entry and vice versa. Our results revealed that when both entry and re-entry tears are 10 mm in diameter, the flow passes through the true and false lumens with smaller resistance, resulting in a smaller flutter of the intimal flap, and therefore more stable intimal flap. Major oscillation frequencies of 2.5 Hz and 7.4 Hz were observed for the oscillation of the intimal flap, and amplitudes of the waves with higher frequencies were negligible.
Collapse
|
41
|
Xu H, Xiong J, Han X, Mei Y, Shi Y, Wang D, Zhang M, Chen D. Computed tomography-based hemodynamic index for aortic dissection. J Thorac Cardiovasc Surg 2020; 162:e165-e176. [PMID: 32217023 DOI: 10.1016/j.jtcvs.2020.02.034] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 02/03/2020] [Accepted: 02/04/2020] [Indexed: 10/25/2022]
Abstract
OBJECTIVE In this study we aimed to propose a new computed tomography-based hemodynamic indicator to quantify the functional significance of aortic dissection and predict post intervention luminal remodeling. METHODS Computational hemodynamics and 3D structural analyses were conducted in 51 patients with type B aortic dissection, at initial presentation and at approximately 1 month, 3 months, and 1 year post intervention. A functional index was proposed on the basis of luminal pressure difference. Statistical relationships between the proposed indicator and longitudinal luminal development were analyzed. RESULTS The computed luminal pressure difference (true lumen pressure minus false lumen pressure) varied overall from positive to negative along the aorta. The first balance position at which the pressure difference equals 0 was proposed as the functional indicator. A more distally located first balance position indicated better functional status. Implantation of stent graft distally shifted this balance position. Patients with the balance position shifted out of the dissected region (43%) presented the highest functional improvement after intervention; whereas those with the balance position shifted to the abdominal region (25%) showed unsatisfactory results. The magnitude of distal shifting of the first balance position at 3 months post intervention was statistically related to the subsequent true lumen expansion and false lumen reduction. CONCLUSIONS The first balance position of luminal pressure difference quantified the hemodynamic status of the dissected aorta. The magnitude of distal shifting of the balance position after intervention was associated with functional improvement and might be used predict longitudinal aortic remodeling.
Collapse
Affiliation(s)
- Huanming Xu
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Jiang Xiong
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China
| | - Xiaofeng Han
- Department of Diagnostic and Interventional Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
| | - Yuqian Mei
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China
| | - Yue Shi
- Department of Engineering and Technology, Meiyin (Beijing) Medical Device Development Ltd, Beijing, China
| | - Dianpeng Wang
- Department of Probability and Statistics, School of Mathematics and Statistics, Beijing Institute of Technology, Beijing, China
| | - Mingchen Zhang
- Department of Mathematics, University of California Santa Barbara, Santa Barbara, Calif
| | - Duanduan Chen
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing, China.
| |
Collapse
|
42
|
Zhu Y, Zhan W, Hamady M, Xu XY. A pilot study of aortic hemodynamics before and after thoracic endovascular repair with a double-branched endograft. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2019. [DOI: 10.1016/j.medntd.2020.100027] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|
43
|
Jarvis K, Pruijssen JT, Son AY, Allen BD, Soulat G, Vali A, Barker AJ, Hoel AW, Eskandari MK, Malaisrie SC, Carr JC, Collins JD, Markl M. Parametric Hemodynamic 4D Flow MRI Maps for the Characterization of Chronic Thoracic Descending Aortic Dissection. J Magn Reson Imaging 2019; 51:1357-1368. [PMID: 31714648 DOI: 10.1002/jmri.26986] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 10/11/2019] [Accepted: 10/16/2019] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Systematic evaluation of complex flow in the true lumen and false lumen (TL, FL) is needed to better understand which patients with chronic descending aortic dissection (DAD) are predisposed to complications. PURPOSE To develop quantitative hemodynamic maps from 4D flow MRI for evaluating TL and FL flow characteristics. STUDY TYPE Retrospective. POPULATION In all, 20 DAD patients (age = 60 ± 11 years; 12 male) (six medically managed type B AD [TBAD], 14 repaired type A AD [rTAAD] now with ascending aortic graft [AAo] or elephant trunk [ET1] repair) and 21 age-matched controls (age = 59 ± 10 years; 13 male) were included. FIELD STRENGTH/SEQUENCE 1.5T, 3T, 4D flow MRI. ASSESSMENT 4D flow MRI was acquired in all subjects. Data analysis included 3D segmentation of TL and FL and voxelwise calculation of forward flow, reverse flow, flow stasis, and kinetic energy as quantitative hemodynamics maps. STATISTICAL TESTS Analysis of variance (ANOVA) or Kruskal-Wallis tests were performed for comparing subject groups. Correlation and Bland-Altman analysis was performed for the interobserver study. RESULTS Patients with rTAAD presented with elevated TL reverse flow (AAo repair: P = 0.004, ET1: P = 0.018) and increased TL kinetic energy (AAo repair: P = 0.0002, ET1: P = 0.011) compared to controls. In addition, TL kinetic energy was increased vs. patients with TBAD (AAo repair: P = 0.021, ET1: P = 0.048). rTAAD was associated with higher FL kinetic energy and lower FL stasis compared to patients with TBAD (AAo repair: P = 0.002, ET1: P = 0.024 and AAo repair: P = 0.003, ET1: P = 0.048, respectively). DATA CONCLUSION Quantitative maps from 4D flow MRI demonstrated global and regional hemodynamic differences between DAD patients and controls. Patients with rTAAD vs. TBAD had significantly altered regional TL and FL hemodynamics. These findings indicate the potential of 4D flow MRI-derived hemodynamic maps to help better evaluate patients with DAD. LEVEL OF EVIDENCE 3 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1357-1368.
Collapse
Affiliation(s)
- Kelly Jarvis
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Judith T Pruijssen
- Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Andre Y Son
- Division of Cardiac Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Bradley D Allen
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Gilles Soulat
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Alireza Vali
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Alex J Barker
- Department of Radiology, University of Colorado, Denver, Colorado, USA
| | - Andrew W Hoel
- Division of Vascular Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Mark K Eskandari
- Division of Vascular Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - S Chris Malaisrie
- Division of Cardiac Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - James C Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | | | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
44
|
Birjiniuk J, Veeraswamy RK, Oshinski JN, Ku DN. Intermediate fenestrations reduce flow reversal in a silicone model of Stanford Type B aortic dissection. J Biomech 2019; 93:101-110. [PMID: 31326118 DOI: 10.1016/j.jbiomech.2019.06.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 06/03/2019] [Accepted: 06/20/2019] [Indexed: 11/17/2022]
Abstract
Pulsatile, three-dimensional hemodynamic forces influence thrombosis, and may dictate progression of aortic dissection. Intimal flap fenestration and blood pressure are clinically relevant variables in this pathology, yet their effects on dissection hemodynamics are poorly understood. The goal of this study was to characterize these effects on flow in dissection models to better guide interventions to prevent aneurysm formation and false lumen flow. Silicone models of aortic dissection with mobile intimal flap were fabricated based on patient images and installed in a flow loop with pulsatile flow. Flow fields were acquired via 4-dimensional flow MRI, allowing for quantification and visualization of relevant fluid mechanics. Pulsatile vortices and jet-like structures were observed at fenestrations immediately past the proximal entry tear. False lumen flow reversal was significantly reduced with the addition of fenestrations, from 19.2 ± 3.3% in two-tear dissections to 4.67 ± 1.5% and 4.87 ± 1.7% with each subsequent fenestration. In contrast, increasing pressure did not cause appreciable differences in flow rates, flow reversal, and vortex formation. Increasing the number of intermediate tears decreased flow reversal as compared to two-tear dissection, which may prevent false lumen thrombosis, promoting persistent false lumen flow. Vortices were noted to result from transluminal fluid motion at distal tear sites, which may lead to degeneration of the opposing wall. Increasing pressure did not affect measured flow patterns, but may contribute to stress concentrations in the aortic wall. The functional and anatomic assessment of disease with 4D MRI may aid in stratifying patient risk in this population.
Collapse
Affiliation(s)
- Joav Birjiniuk
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332-0405, United States.
| | - Ravi K Veeraswamy
- Division of Vascular Surgery, Department of Surgery, Medical University of South Carolina, 114 Doughty Street Suite BM 654 MSC 295, Charleston, SC 29425, United States
| | - John N Oshinski
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332-0405, United States; Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1364 Clifton Road NE Suite D112, Atlanta, GA 30322, United States
| | - David N Ku
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332-0405, United States; Division of Vascular Surgery, Joseph B. Whitehead Department of Surgery, Emory University School of Medicine, 1365 Clifton Road, Atlanta, GA 30322, United States
| |
Collapse
|