Higa T, Ketterling JA, Mamou J, Hoerig C, Nagano N, Hirata S, Yoshida K, Yamaguchi T. Relationship between transmission/reception conditions of high-frequency plane wave compounding and evaluation accuracy of extended amplitude envelope statistics. JAPANESE JOURNAL OF APPLIED PHYSICS (2008) 2024; 63:04SP81. [PMID: 38911013 PMCID: PMC11192551 DOI: 10.35848/1347-4065/ad3a70] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/25/2024]
Abstract
The double-Nakagami (DN) model provides a method for analyzing the amplitude envelope statistics of quantitative ultrasound (QUS). In this study, the relationship between the sound field characteristics and the robustness of QUS evaluation was evaluated using five HF linear array probes and tissue-mimicking phantoms. Compound plane-wave imaging (CPWI) was used to acquire echo data. Five phantoms containing two types of scatterers were used to mimic fatty liver tissue. After clarifying the relationship between the sound field characteristics of the probes and QUS parameters, DN QUS parameters in 10 rat livers with different lipidification were evaluated using one HF linear array probe. For both phantom and in situ liver analyses, correlations between fat content and multiple QUS parameters were confirmed, suggesting that the combination of CPWI using a HF linear array probe with the DN model is a robust method for quantifying fatty liver and has potential clinical diagnostic applications.
Collapse
Affiliation(s)
- Taisei Higa
- Graduate School of Science and Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Jeffrey A. Ketterling
- Department of Radiology, Weill Cornell Medicine, New York, NY 10022, United States of America
| | - Jonathan Mamou
- Department of Radiology, Weill Cornell Medicine, New York, NY 10022, United States of America
| | - Cameron Hoerig
- Department of Radiology, Weill Cornell Medicine, New York, NY 10022, United States of America
| | - Nahoko Nagano
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Shinnosuke Hirata
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Kenji Yoshida
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Tadashi Yamaguchi
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| |
Collapse
|
2
|
Ringgaard E, Levassort F, Wang K, Vaitekunas J, Nagata H. Lead-Free Piezoelectric Transducers. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:3-15. [PMID: 38060358 DOI: 10.1109/tuffc.2023.3340950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
Research activities on lead-free piezoelectric materials have been ongoing for over 20 years. Generally, the applicability of the main material families is less universal than that of lead-based compositions such as lead zirconate titanate, but in some cases, the corresponding applications have already been identified. Due to the extensive research, it is now possible to manufacture demonstrators and prototypes for different applications and the authors propose in this article to take stock of these advances. For this, we have chosen to first recall briefly the main new material systems using a simplistic "soft" and "hard" classification for approaching the various resonant transducer applications. Medical imaging applications that represent one of the most important fields are presented in a second step together with other low-power transducers. Then, a variety of applications are merged under the heading of high-power transducers. In addition, we mention two points that are important to consider when manufacturing at a larger scale. For the design of transducers, complete datasets must be available, especially if modeling tools are used. Finally, the commercialization of these lead-free materials imposes essential secondary requirements in terms of availability, reproducibility, sample size, and so on.
Collapse
|
3
|
Gunderman A, Montayre R, Ranjan A, Chen Y. Review of Robot-Assisted HIFU Therapy. SENSORS (BASEL, SWITZERLAND) 2023; 23:3707. [PMID: 37050766 PMCID: PMC10098661 DOI: 10.3390/s23073707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/07/2023] [Accepted: 03/14/2023] [Indexed: 06/19/2023]
Abstract
This paper provides an overview of current robot-assisted high-intensity focused ultrasound (HIFU) systems for image-guided therapies. HIFU is a minimally invasive technique that relies on the thermo-mechanical effects of focused ultrasound waves to perform clinical treatments, such as tumor ablation, mild hyperthermia adjuvant to radiation or chemotherapy, vein occlusion, and many others. HIFU is typically performed under ultrasound (USgHIFU) or magnetic resonance imaging guidance (MRgHIFU), which provide intra-operative monitoring of treatment outcomes. Robot-assisted HIFU probe manipulation provides precise HIFU focal control to avoid damage to surrounding sensitive anatomy, such as blood vessels, nerve bundles, or adjacent organs. These clinical and technical benefits have promoted the rapid adoption of robot-assisted HIFU in the past several decades. This paper aims to present the recent developments of robot-assisted HIFU by summarizing the key features and clinical applications of each system. The paper concludes with a comparison and discussion of future perspectives on robot-assisted HIFU.
Collapse
Affiliation(s)
- Anthony Gunderman
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Rudy Montayre
- Department of Physiological Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK 74078, USA
| | - Ashish Ranjan
- Department of Physiological Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK 74078, USA
| | - Yue Chen
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| |
Collapse
|
4
|
Banquart A, Calle S, Gregoire JM, Ossant F, Fritsch L, Capri A, Inglese JM, Chevalliot S, Levassort F. Inkjet-printed P(VDF-TrFE) film for high-frequency annular array. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; PP:313-323. [PMID: 37022397 DOI: 10.1109/tuffc.2023.3242073] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
An innovative processing to deposit P(VDF-TrFE) film on silicon wafers by an inkjet printing method was used to fabricate high-frequency annular array prototype. This prototype has a total aperture of 7.3 mm and 8 active elements. A polymer-based lens with low acoustic attenuation was added to the flat deposition on the wafer, setting the geometric focus to 13.8 mm. With a thickness of around 11 μm, the electromechanical performance of P(VDF-TrFE) films was evaluated with an effective thickness coupling factor of 22%. Electronics allowing all elements to simultaneously emit as a single element transducer was developed. In reception, a dynamic focusing, based on eight independent amplifying channels, was preferred. The center frequency of the prototype was 21.3 MHz, the insertion loss was 48.5 dB and the -6 dB fractional bandwidth was 143%. The trade-off sensitivity/bandwidth has rather favored the large bandwidth. Dynamic focusing on reception was applied and allowed to improvements in the lateral-full width at half maximum as shown on images obtained with a wire phantom at several depths. The next step, for a fully operational multi-element transducer, will be to achieve a significant increase of the acoustic attenuation in the silicon wafer.
Collapse
|
5
|
Aristizábal O, Qiu Z, Gallego E, Aristizábal M, Mamou J, Wang Y, Ketterling JA, Turnbull DH. Longitudinal in Utero Analysis of Engrailed-1 Knockout Mouse Embryonic Phenotypes Using High-Frequency Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:356-367. [PMID: 36283941 PMCID: PMC9712241 DOI: 10.1016/j.ultrasmedbio.2022.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 09/08/2022] [Accepted: 09/11/2022] [Indexed: 06/16/2023]
Abstract
Large-scale international efforts to generate and analyze loss-of-function mutations in each of the approximately 20,000 protein-encoding gene mutations are ongoing using the "knockout" mouse as a model organism. Because one-third of gene knockouts are expected to result in embryonic lethality, it is important to develop non-invasive in utero imaging methods to detect and monitor mutant phenotypes in mouse embryos. We describe the utility of 3-D high-frequency (40-MHz) ultrasound (HFU) for longitudinal in utero imaging of mouse embryos between embryonic days (E) 11.5 and E14.5, which represent critical stages of brain and organ development. Engrailed-1 knockout (En1-ko) mouse embryos and their normal control littermates were imaged with HFU in 3-D, enabling visualization of morphological phenotypes in the developing brains, limbs and heads of the En1-ko embryos. Recently developed deep learning approaches were used to automatically segment the embryonic brain ventricles and bodies from the 3-D HFU images, allowing quantitative volumetric analyses of the En1-ko brain phenotypes. Taken together, these results show great promise for the application of longitudinal 3-D HFU to analyze knockout mouse embryos in utero.
Collapse
Affiliation(s)
- Orlando Aristizábal
- Skirball Institute of Biomolecular Medicine and Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Ziming Qiu
- Department of Electrical and Computer Engineering, New York University Tandon School of Engineering, New York, New York, USA
| | - Estefania Gallego
- Skirball Institute of Biomolecular Medicine and Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Matias Aristizábal
- Skirball Institute of Biomolecular Medicine and Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA
| | - Jonathan Mamou
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | - Yao Wang
- Department of Electrical and Computer Engineering, New York University Tandon School of Engineering, New York, New York, USA
| | | | - Daniel H Turnbull
- Skirball Institute of Biomolecular Medicine and Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
| |
Collapse
|
6
|
Ren D, Li C, Shi J, Chen R. A Review of High-Frequency Ultrasonic Transducers for Photoacoustic Imaging Applications. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1848-1858. [PMID: 34941509 DOI: 10.1109/tuffc.2021.3138158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Photoacoustic imaging (PAI) is a new and rapidly growing hybrid biomedical imaging modality that combines the virtues of both optical and ultrasonic (US) imaging. The nature of the interaction between light and ultrasound waves allows PAI to make good use of the rich contrast produced by optics while retaining the imaging depths in US imaging. High-frequency US transducers are an important part of the PAI systems, used to detect the high-frequency and broad-bandwidth photoacoustic signals excited by the target tissues irradiated by short laser pulses. Advancement in high-frequency US transducer technology has influenced the boost of PAI to broad applications. Here, we present a review on high-frequency US transducer technologies for PAI applications, including advanced piezoelectric materials and representative transducers. In addition, we discuss the new challenges and directions facing the development of high-frequency US transducers for PAI applications.
Collapse
|
7
|
Zhang M, Narumi R, Azuma T, Okita K, Takagi S. Numerical study on sector-vortex phased irradiation method using annular array transducer in High-Intensity Focused Ultrasound treatment. ULTRASONICS 2021; 115:106464. [PMID: 34000665 DOI: 10.1016/j.ultras.2021.106464] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 04/17/2021] [Accepted: 05/04/2021] [Indexed: 06/12/2023]
Abstract
Sector-vortex phased irradiation from annular array transducer was numerically studied with breast model constructed from MRI data of real patient. Phase compensation (PC) based on time reversal pre-computation was applied in order to handle phase delay caused by heterogeneity of breast tissues, and results showed great effectiveness on single-focus case, insignificant effectiveness on multi-focus cases with 4 and 8 phase-sectors, but ineffectiveness on multi-focus case with 12 phase-sectors, where enormous undesired outer ablation occurred. For single-focus case, phase compensation not only produced real focus very close to targeted site (0.1 mm deviation), but also decreased thermal peak ratio (outer/focal) largely by 30%. However, phase compensation did not increase total ablated size. For multi-focus cases with 4 and 8 phase-sectors, deformed focal shapes by tissue heterogeneity were restored by phase compensation, but the 4-phase-sector case had higher thermal peak ratio and smaller ablation than 8-phase-sector case for strong cancelling effect between phase-sector borders. Ineffectiveness of phase compensation on multi-focus case with 12 phase-sectors had three considerable reasons. 1st, inequality of piezo-element number between sectors; 2nd, heterogeneous attenuation of breast model; 3rd, insufficient number of piezo-elements per sector; where the 2nd reason originated from breast model, and other two reasons were related to array transducer. This research gave several preliminary indications. 1st, ineffectiveness of phase compensation occurs on case with large phase-sector number when using annular array transducer; 2nd, with same input energy and same irradiation time, sector-vortex phased irradiation creates smaller focal ablation, but withstands longer than single-focus irradiation free of outer ablation; 3rd, phase-difference π between neighboring phase-sectors is disadvantageous because of energy loss; 4th, phase compensation is effective on single-focus for improving pinpoint ablation but not for increasing total ablated size.
Collapse
Affiliation(s)
- Mingzhen Zhang
- The University of Tokyo, Dept. of Mechanical Engineering, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Ryuta Narumi
- The University of Tokyo, Dept. of Bioengineering, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Takashi Azuma
- The University of Tokyo, Dept. of Bioengineering, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Kohei Okita
- Nihon University, College of Industrial Technology, 1-2-1 Izumi-cho, Narashino, Chiba 275-8575, Japan
| | - Shu Takagi
- The University of Tokyo, Dept. of Mechanical Engineering, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| |
Collapse
|
8
|
Qiu Z, Xu T, Langerman J, Das W, Wang C, Nair N, Aristizabal O, Mamou J, Turnbull DH, Ketterling JA, Wang Y. A Deep Learning Approach for Segmentation, Classification, and Visualization of 3-D High-Frequency Ultrasound Images of Mouse Embryos. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2460-2471. [PMID: 33755564 PMCID: PMC8274381 DOI: 10.1109/tuffc.2021.3068156] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Segmentation and mutant classification of high-frequency ultrasound (HFU) mouse embryo brain ventricle (BV) and body images can provide valuable information for developmental biologists. However, manual segmentation and identification of BV and body requires substantial time and expertise. This article proposes an accurate, efficient and explainable deep learning pipeline for automatic segmentation and classification of the BV and body. For segmentation, a two-stage framework is implemented. The first stage produces a low-resolution segmentation map, which is then used to crop a region of interest (ROI) around the target object and serve as the probability map of the autocontext input for the second-stage fine-resolution refinement network. The segmentation then becomes tractable on high-resolution 3-D images without time-consuming sliding windows. The proposed segmentation method significantly reduces inference time (102.36-0.09 s/volume ≈ 1000× faster) while maintaining high accuracy comparable to previous sliding-window approaches. Based on the BV and body segmentation map, a volumetric convolutional neural network (CNN) is trained to perform a mutant classification task. Through backpropagating the gradients of the predictions to the input BV and body segmentation map, the trained classifier is found to largely focus on the region where the Engrailed-1 (En1) mutation phenotype is known to manifest itself. This suggests that gradient backpropagation of deep learning classifiers may provide a powerful tool for automatically detecting unknown phenotypes associated with a known genetic mutation.
Collapse
|
9
|
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays. Nat Biomed Eng 2021; 5:749-758. [PMID: 34272524 DOI: 10.1038/s41551-021-00763-4] [Citation(s) in RCA: 67] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 06/10/2021] [Indexed: 02/06/2023]
Abstract
Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.
Collapse
|
10
|
Wang Z, Yang F, Ma H, Cheng Z, Yang S. Photoacoustic and ultrasound (PAUS) dermoscope with high sensitivity and penetration depth by using a bimorph transducer. JOURNAL OF BIOPHOTONICS 2020; 13:e202000145. [PMID: 32506704 DOI: 10.1002/jbio.202000145] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/29/2020] [Accepted: 06/02/2020] [Indexed: 06/11/2023]
Abstract
A bimorph transducer was proposed to improve the detection sensitivity and imaging depth of photoacoustic and ultrasound (PAUS) dermoscope. By applying the bimorph transducer, the imaging depth and sensitivity of PAUS dermoscope were enhanced by simultaneously improving excitation efficiency and reception bandwidth. The integrated design of the imaging head of the dermoscope makes it highly convenient for detecting human skin. The PAUS imaging performance was demonstrated via visualizing subcutaneous tumor and depicting full structures of different skin layers from epidermis to subcutaneous tissue. The results confirm that the dermoscope with the bimorph transducer is well suited for PA and US dual-modality imaging, which can provide multi-information for skin disease.
Collapse
Affiliation(s)
- Zhiyang Wang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Fei Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Haigang Ma
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Zhongwen Cheng
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Sihua Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| |
Collapse
|
11
|
Manwar R, Kratkiewicz K, Avanaki K. Overview of Ultrasound Detection Technologies for Photoacoustic Imaging. MICROMACHINES 2020; 11:E692. [PMID: 32708869 PMCID: PMC7407969 DOI: 10.3390/mi11070692] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 07/14/2020] [Accepted: 07/14/2020] [Indexed: 12/15/2022]
Abstract
Ultrasound detection is one of the major components of photoacoustic imaging systems. Advancement in ultrasound transducer technology has a significant impact on the translation of photoacoustic imaging to the clinic. Here, we present an overview on various ultrasound transducer technologies including conventional piezoelectric and micromachined transducers, as well as optical ultrasound detection technology. We explain the core components of each technology, their working principle, and describe their manufacturing process. We then quantitatively compare their performance when they are used in the receive mode of a photoacoustic imaging system.
Collapse
Affiliation(s)
- Rayyan Manwar
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA;
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| | - Karl Kratkiewicz
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
| | - Kamran Avanaki
- Richard and Loan Hill Department of Bioengineering, University of Illinois at Chicago, Chicago, IL 60607, USA;
- Department of Biomedical Engineering, Wayne State University, Detroit, MI 48201, USA;
- Department of Dermatology, University of Illinois at Chicago, Chicago, IL 60607, USA
| |
Collapse
|
12
|
Mizoguchi T, Yoshida K, Mamou J, Ketterling JA, Yamaguchi T. Improved evaluation of backscatter characteristics of soft tissue using high-frequency annular array. JAPANESE JOURNAL OF APPLIED PHYSICS (2008) 2020; 59:SKKE17. [PMID: 34744182 PMCID: PMC8570616 DOI: 10.35848/1347-4065/ab8bcb] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Clinical ultrasound is widely used for quantitative diagnosis. To clarify the relationship between anatomical and acoustic properties, high resolution imaging using high-frequency ultrasound (HFU) is required. However, when tissue properties are evaluated using HFU, the depth of field (DOF) is limited. To overcome this problem, an annular array transducer, which has a simple structure and produces high-quality images, is applied to HFU measurement. In previous phantom experiments, we demonstrated that the HFU annular array extends the DOF compared to that of a single-element transducer for quantitative ultrasound (QUS) analysis. Here, we extend that work by applying QUS methods to an ex vivo rat liver. The present study demonstrates that an annular array extends the region and improves the resolution for tissue characterization for an excised healthy rat liver. Amplitude envelope statistics and spectral-based analysis are used as QUS methods.
Collapse
Affiliation(s)
- Takeru Mizoguchi
- Graduate School of Science and Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Kenji Yoshida
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Jonathan Mamou
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY 10038, United States of America
| | - Jeffrey A. Ketterling
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY 10038, United States of America
| | - Tadashi Yamaguchi
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| |
Collapse
|
13
|
Torke PR, Nuster R, Paltauf G. Conical ring array detector for large depth of field photoacoustic macroscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:2461-2475. [PMID: 32499937 PMCID: PMC7249821 DOI: 10.1364/boe.386585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 01/31/2020] [Accepted: 02/26/2020] [Indexed: 05/07/2023]
Abstract
Photoacoustic microscopy and macroscopy (PAM) using focused detector scanning are emerging imaging methods for biological tissue, providing high resolution and high sensitivity for structures with optical absorption contrast. However, achieving a constant lateral resolution over a large depth of field for deeply penetrating photoacoustic macroscopy is still a challenge. In this work, a detector design for scanning photoacoustic macroscopy is presented. Based on simulation results, a sensor array geometry is developed and fabricated that consists of concentric ring elements made of polyvinylidene fluoride (PVDF) film in a geometry that combines a centered planar ring with several inclined outer ring elements. The reconstruction algorithm, which uses dynamic focusing and coherence weighting, is explained and its capability to reduce artefacts occurring for single element conical sensors is demonstrated. Several phantoms are manufactured to evaluate the performance of the array in experimental measurements. The sensor array provides a constant axial and lateral resolution of 95 µm and 285 µm, respectively, over a depth of field of 20 mm. The depth of field corresponds approximately to the maximum imaging depth in biological tissue, estimated from the sensitivity of the array. With its ability to achieve the maximum resolution even with a very small scanning range, the array is believed to have applications in the imaging of limited regions of interest buried in biological tissue.
Collapse
|
14
|
Improved Depth-of-Field Photoacoustic Microscopy with a Multifocal Point Transducer for Biomedical Imaging. SENSORS 2020; 20:s20072020. [PMID: 32260296 PMCID: PMC7181221 DOI: 10.3390/s20072020] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 03/21/2020] [Accepted: 04/02/2020] [Indexed: 12/24/2022]
Abstract
In this study, a photoacoustic microscopy (PAM) system based on a multifocal point (MFP) transducer was fabricated to produce a large depth-of-field tissue image. The customized MFP transducer has seven focal points, distributed along with the transducer’s axis, fabricated by separate spherically-focused surfaces. These surfaces generate distinct focal zones that are overlapped to extend the depth-of-field. This design allows extending the focal zone of 10 mm for the 11 MHz MFP transducer, which is a great improvement over the 0.48 mm focal zone of the 11 MHz single focal point (SFP) transducer. The PAM image penetration depths of a chicken-hemoglobin phantom using SFP and MFP transducers were measured as 5 mm and 8 mm, respectively. The significant increase in the PAM image-based penetration depth of the chicken-hemoglobin phantom was a result of using the customized MFP transducer.
Collapse
|
15
|
Abstract
A wide range of medical devices have significant electronic components. Compared to open-source medical software, open (and open-source) electronic hardware has been less published in peer-reviewed literature. In this review, we explore the developments, significance, and advantages of using open platform electronic hardware for medical devices. Open hardware electronics platforms offer not just shorter development times, reduced costs, and customization; they also offer a key potential advantage which current commercial medical devices lack—seamless data sharing for machine learning and artificial intelligence. We explore how various electronic platforms such as microcontrollers, single board computers, field programmable gate arrays, development boards, and integrated circuits have been used by researchers to design medical devices. Researchers interested in designing low cost, customizable, and innovative medical devices can find references to various easily available electronic components as well as design methodologies to integrate those components for a successful design.
Collapse
|
16
|
Fatima A, Kratkiewicz K, Manwar R, Zafar M, Zhang R, Huang B, Dadashzadeh N, Xia J, Avanaki K(M. Review of cost reduction methods in photoacoustic computed tomography. PHOTOACOUSTICS 2019; 15:100137. [PMID: 31428558 PMCID: PMC6693691 DOI: 10.1016/j.pacs.2019.100137] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 05/11/2019] [Accepted: 06/13/2019] [Indexed: 05/18/2023]
Abstract
Photoacoustic Computed Tomography (PACT) is a major configuration of photoacoustic imaging, a hybrid noninvasive modality for both functional and molecular imaging. PACT has rapidly gained importance in the field of biomedical imaging due to superior performance as compared to conventional optical imaging counterparts. However, the overall cost of developing a PACT system is one of the challenges towards clinical translation of this novel technique. The cost of a typical commercial PACT system originates from optical source, ultrasound detector, and data acquisition unit. With growing applications of photoacoustic imaging, there is a tremendous demand towards reducing its cost. In this review article, we have discussed various approaches to reduce the overall cost of a PACT system, and provided a cost estimation to build a low-cost PACT system.
Collapse
Affiliation(s)
- Afreen Fatima
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
- Department of Electrical & Computer Engineering, Wayne State University, Detroit, MI, USA
| | - Karl Kratkiewicz
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | - Rayyan Manwar
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | - Mohsin Zafar
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | | | - Bin Huang
- 3339 Northwest Ave, Bellingham, WA, USA
| | | | - Jun Xia
- Department of Biomedical Engineering, The State University of New York, Buffalo, NY, USA
| | - Kamran (Mohammad) Avanaki
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
- Department of Neurology, Wayne State University School of Medicine, Detroit, MI, USA
- Molecular Imaging Program, Barbara Ann Karmanos Cancer Institute, Wayne State University, Detroit, MI, USA
| |
Collapse
|
17
|
Mizoguchi T, Tamura K, Mamou J, Ketterling JA, Yoshida K, Yamaguchi T. Comprehensive backscattering characteristics analysis for quantitative ultrasound with an annular array: a basic study on homogeneous scattering phantom. JAPANESE JOURNAL OF APPLIED PHYSICS (2008) 2019; 58:SGGE08. [PMID: 31327873 PMCID: PMC6641553 DOI: 10.7567/1347-4065/ab0df9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
High-frequency ultrasound (HFU, >20 MHz) and quantitative ultrasound (QUS) methods permit a means to understand the relationship between anatomical and acoustic characteristics. In our previous research, we showed that analyzing the acoustic scattering with HFU was an effective method for noninvasive diagnosis. However, the depth of field (DOF) of HFU transducers was limited, which constrains the range of QUS analysis. In this study, we seek to improve the accuracy of HFU, QUS-based parameters on the envelope statistics and frequency-based analysis by using an annular array that allows for an extended DOF. A 20-MHz annular-array transducer with five elements was employed to obtain signals which were beamformed in post-processing. Two kinds of low concentration scattering phantoms were scanned with 30-μm step size. Two QUS analysis techniques were employed: the Nakagami distribution and the reflector method. The results demonstrated that the annular array provides a stable analysis over an extended axial range.
Collapse
Affiliation(s)
- Takeru Mizoguchi
- Graduate School of Science and Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Kazuki Tamura
- Graduate School of Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Jonathan Mamou
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY 10038, United States of America
| | - Jeffrey A. Ketterling
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY 10038, United States of America
| | - Kenji Yoshida
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| | - Tadashi Yamaguchi
- Center for Frontier Medical Engineering, Chiba University, Yayoicho, Inage, Chiba 263-8522, Japan
| |
Collapse
|
18
|
Nguyen TP, Truong NTP, Bui NQ, Nguyen VT, Hoang G, Choi J, Phan TTV, Pham VH, Kim BG, Oh J. Design, Fabrication, and Evaluation of Multifocal Point Transducer for High-Frequency Ultrasound Applications. SENSORS (BASEL, SWITZERLAND) 2019; 19:E609. [PMID: 30717095 PMCID: PMC6386936 DOI: 10.3390/s19030609] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 01/28/2019] [Accepted: 01/29/2019] [Indexed: 12/30/2022]
Abstract
The present study illustrates the design, fabrication, and evaluation of a novel multifocal point (MFP) transducer based on polyvinylidene fluoride (PVDF) film for high-frequency ultrasound application. The fabricated MFP surface was press-focused using a computer numerical control (CNC) machining tool-customized multi-spherical pattern object. The multi-spherical pattern has five spherical surfaces with equal area and connected continuously to have the same energy level at focal points. Center points of these spheres are distributed in a linear pattern with 1 mm distance between each two points. The radius of these spheres increases steadily from 10 mm to 13.86 mm. The designed MFP transducer had a center frequency of 50 MHz and a -6 dB bandwidth of 68%. The wire phantom test was conducted to study and demonstrate the advantages of this novel design. The obtained results for MFP transducer revealed a significant increase (4.3 mm) of total focal zone in the near-field and far-field area compared with 0.48 mm obtained using the conventional single focal point transducer. Hence, the proposed method is promising to fabricate MFP transducers for deeper imaging depth applications.
Collapse
Affiliation(s)
- Thanh Phuoc Nguyen
- Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea.
- Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan 48513, Korea.
| | - Nguyen Thanh Phong Truong
- Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea.
| | - Nhat Quang Bui
- Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan 48513, Korea.
| | - Van Tu Nguyen
- Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea.
| | - Giang Hoang
- Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan 48513, Korea.
| | - Jaeyeop Choi
- Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea.
| | - Thi Tuong Vy Phan
- Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea.
- Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan 48513, Korea.
| | - Van Hiep Pham
- Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea.
| | - Byung-Gak Kim
- College of Future Convergence, Pukyong National University, Busan 48513, Korea.
| | - Junghwan Oh
- Interdisciplinary Program of Biomedical Mechanical and Electrical Engineering, Pukyong National University, Busan 48513, Korea.
- Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan 48513, Korea.
- Department of Biomedical Engineering, Pukyong National University, Busan 48513, Korea.
| |
Collapse
|
19
|
Lee JE, Leung SN. Multi-stage crystallization mechanism of electroactive phase polyvinylidene fluoride induced by thermal and supercritical carbon dioxide processing. CrystEngComm 2018. [DOI: 10.1039/c8ce00531a] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The multi-stage crystallization mechanism of electroactive PVDF induced by thermal and supercritical CO2 processing was identified.
Collapse
Affiliation(s)
- Ji Eun Lee
- Department of Mechanical Engineering
- Lassonde School of Engineering
- York University
- Toronto
- M3J 1P3 Canada
| | - Siu Ning Leung
- Department of Mechanical Engineering
- Lassonde School of Engineering
- York University
- Toronto
- M3J 1P3 Canada
| |
Collapse
|
20
|
Diagnostic Imaging of the Anterior Segment in Glaucoma: An Update. Int Ophthalmol Clin 2017; 57:125-136. [PMID: 28590286 DOI: 10.1097/iio.0000000000000173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
21
|
A Wideband High-Voltage Power Amplifier Post-Linearizer for Medical Ultrasound Transducers. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7040354] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
22
|
Qiu W, Xia J, Shi Y, Mu P, Wang X, Gao M, Wang C, Xiao Y, Yang G, Liu J, Sun L, Zheng H. A Delayed-Excitation Data Acquisition Method for High-Frequency Ultrasound Imaging. IEEE Trans Biomed Eng 2017; 65:15-20. [PMID: 28368803 DOI: 10.1109/tbme.2017.2687948] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
High-frequency ultrasound imaging (at >20 MHz) has gained widespread attention due to its high spatial resolution being useful for basic cardiovascular and cancer research involving small animals. The sampling rate of the analog-to-digital converter in a high-frequency ultrasound system usually needs to be higher than 120 MHz in order to satisfy the Nyquist sampling-rate requirement. However, the sampling rate is typically within the range of 40-60 MHz in a traditional ultrasound system, and so we propose a delayed-excitation method for performing high-frequency ultrasound imaging with a traditional data acquisition scheme. In this method, the transmitted pulse is delayed by a certain time period so that the ultrasound echo data are aligned into high-sampling-rate slots. Wire and tissue-mimicking phantoms were imaged to evaluate the performance of the proposed method, whereas a porcine small-intestine specimen and an excised rabbit eyeball were used for in vitro imaging evaluations. The test results demonstrate that the proposed method allows high-frequency ultrasound imaging to be implemented using a traditional ultrasound sampling system.
Collapse
|
23
|
Lee JE, Guo Y, Lee RE, Leung SN. Fabrication of electroactive poly(vinylidene fluoride) through non-isothermal crystallization and supercritical CO2 processing. RSC Adv 2017. [DOI: 10.1039/c7ra09162a] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A new strategy using non-isothermal crystallization and supercritical CO2 processing is found to promote the electroactive phase content in PVDF.
Collapse
Affiliation(s)
- Ji Eun Lee
- Department of Mechanical Engineering
- Lassonde School of Engineering
- York University
- Toronto
- Canada
| | - Yanting Guo
- Department of Mechanical Engineering
- Lassonde School of Engineering
- York University
- Toronto
- Canada
| | - Richard Eungkee Lee
- Department of Mechanical Engineering
- Lassonde School of Engineering
- York University
- Toronto
- Canada
| | - Siu Ning Leung
- Department of Mechanical Engineering
- Lassonde School of Engineering
- York University
- Toronto
- Canada
| |
Collapse
|
24
|
Abstract
The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via ciliodestruction), tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities.
Collapse
Affiliation(s)
- Ronald H Silverman
- Department of Ophthalmology, Columbia University Medical Center
- F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA
| |
Collapse
|
25
|
High Frequency Ex Vivo Ultrasound Imaging of the Middle Ear to Show Simulated Ossicular Pathology. Otol Neurotol 2016; 37:586-92. [DOI: 10.1097/mao.0000000000001003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
26
|
Chitnis PV, Aristizábal O, Filoux E, Sampathkumar A, Mamou J, Ketterling JA. Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer. ULTRASONIC IMAGING 2016; 38:32-43. [PMID: 25925675 PMCID: PMC5002350 DOI: 10.1177/0161734615583981] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
This paper presents an adaptive synthetic-focusing scheme that, when applied to photoacoustic (PA) data acquired using an annular array, improves focusing across a greater imaging depth and enhances spatial resolution. The imaging system was based on a 40-MHz, 5-element, annular-array transducer with a focal length of 12 mm and an 800-µm diameter hole through its central element to facilitate coaxial delivery of 532-nm laser. The transducer was raster-scanned to facilitate 3D acquisition of co-registered ultrasound and PA image data. Three synthetic-focusing schemes were compared for obtaining PA A-lines for each scan location: delay-and-sum (DAS), DAS weighted with a coherence factor (DAS + CF), and DAS weighted with a sign-coherence factor (DAS + SCF). Bench-top experiments that used an 80-µm hair were performed to assess the enhancement provided by the two coherence-based schemes. Both coherence-based schemes increased the signal-to-noise ratio by approximately 10 dB. When processed using the DAS-only scheme, the lateral dimension of the hair in a PA image with 20 dB dynamic range was between 300 µm and 1 mm for imaging depth ranging from 8 to 20 mm. In comparison, the DAS + CF scheme resulted in a lateral dimension of 200 to 450 µm over the same range. The DAS + SCF synthetic focusing further improved the smallest-resolvable dimension, which was between 150 and 400 µm over the same range of imaging depth. When used on PA data obtained from a 12-day-old mouse embryo, the DAS + SCF processing improved visualization of neurovasculature.
Collapse
Affiliation(s)
- Parag V Chitnis
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA
| | - Orlando Aristizábal
- Skirball Institute of Biomolecular Medicine, NYU School of Medicine, New York, NY, USA
| | - Erwan Filoux
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA
| | - Ashwin Sampathkumar
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA
| | - Jonathan Mamou
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA
| | - Jeffrey A Ketterling
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA
| |
Collapse
|
27
|
Cha JH, Kang B, Jang J, Chang JH. A 15-MHz 1-3 Piezocomposite Concave Array Transducer for Ophthalmic Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:1994-2004. [PMID: 26881281 DOI: 10.1109/tuffc.2015.007288] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Because of the spherical shape of the human eye, the anterior segments of the eye, particularly the cornea and the lens, create high levels of refraction and reflection of ultrasound which negatively affect the performance of linear and convex arrays. To minimize the ultrasound energy loss, a 15-MHz concave array transducer was designed, fabricated, and characterized; its footprint is able to mesh well with the shape of the cornea. The concave array has a curvature with a radius of 15 mm and 128 elements with a 1.44- pitch. Its elevational focus and view angle are 30 mm and 72.3°, respectively, thus allowing the imaging area to cover the retinal region of interest in the posterior segment. As an active layer, a 1-3 piezocomposite was designed and fabricated in response to the bidirectional (i.e., azimuthal and elevational) curvature of the concave array and the high coupling coefficient. From the performance evaluation, it was found that the completed concave array is able to provide a center frequency of 15.95 MHz and a -6-dB fractional bandwidth of 67.8% after electrical tuning has been conducted. The crosstalk level was measured to be less than -25 dB. It was verified that the concave array is robust to the refraction and reflection from the cornea through pulse-echo testing using a custom-made eye-mimicking phantom. Furthermore, images of both the wire-target phantom and the ex vivo porcine eye were acquired by the finished concave array, which was connected to a commercial ultrasound scanner equipped with a research package. The evaluation results demonstrated that the developed concave array transducer is a possible alternative to conventional arrays for effectively imaging the posterior segment of the eye.
Collapse
|
28
|
Brown J, Sharma S, Leadbetter J, Cochran S, Adamson R. Mass-spring matching layers for high-frequency ultrasound transducers: a new technique using vacuum deposition. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:1911-1921. [PMID: 25389169 DOI: 10.1109/tuffc.2014.006480] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We have developed a technique of applying multiple matching layers to high-frequency (>30 MHz) imaging transducers, by using carefully controlled vacuum deposition alone. This technique uses a thin mass-spring matching layer approach that was previously described in a low-frequency (1 to 10 MHz) transducer design with epoxied layers. This mass- spring approach is more suitable to vacuum deposition in highfrequency transducers over the conventional quarter-wavelength resonant cavity approach, because thinner layers and more versatile material selection can be used, the difficulty in precisely lapping quarter-wavelength matching layers is avoided, the layers are less attenuating, and the layers can be applied to a curved surface. Two different 3-mm-diameter 45-MHz planar lithium niobate transducers and one geometrically curved 3-mm lithium niobate transducer were designed and fabricated using this matching layer approach with copper as the mass layer and parylene as the spring layer. The first planar lithium niobate transducer used a single mass-spring matching network, and the second planar lithium niobate transducer used a single mass-spring network to approximate the first layer in a dual quarter-wavelength matching layer system in addition to a conventional quarter-wavelength layer as the second matching layer. The curved lithium niobate transducer was press focused and used a similar mass-spring plus quarter-wavelength matching layer network. These transducers were then compared with identical transducers with no matching layers and the performance improvement was quantified. The bandwidth of the lithium niobate transducer with the single mass-spring layer was measured to be 46% and the insertion loss was measured to be -21.9 dB. The bandwidth and insertion loss of the lithium niobate transducer with the mass-spring network plus quarter-wavelength matching were measured to be 59% and -18.2 dB, respectively. These values were compared with the unmatched transducer, which had a bandwidth of 28% and insertion loss of -34.1 dB. The bandwidth and insertion loss of the curved lithium niobate transducer with the mass-spring plus quarter-wavelength matching layer combination were measured to be 68% and -26 dB, respectively; this compared with the measured unmatched bandwidth and insertion loss of 35% and -37 dB. All experimentally measured values were in excellent agreement with theoretical Krimholtz-Leedom-Matthaei (KLM) model predictions.
Collapse
|
29
|
Dual-element transducer with phase-inversion for wide depth of field in high-frequency ultrasound imaging. SENSORS 2014; 14:14278-88. [PMID: 25098208 PMCID: PMC4179078 DOI: 10.3390/s140814278] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 07/14/2014] [Accepted: 07/28/2014] [Indexed: 01/04/2023]
Abstract
In high frequency ultrasound imaging (HFUI), the quality of focusing is deeply related to the length of the depth of field (DOF). In this paper, a phase-inversion technique implemented by a dual-element transducer is proposed to enlarge the DOF. The performance of the proposed method was numerically demonstrated by using the ultrasound simulation program called Field-II. A simulated dual-element transducer was composed of a disc- and an annular-type elements, and its aperture was concavely shaped to have a confocal point at 6 mm. The area of each element was identical in order to provide same intensity at the focal point. The outer diameters of the inner and the outer elements were 2.1 mm and 3 mm, respectively. The center frequency of each element was 40 MHz and the f-number (focal depth/aperture size) was two. When two input signals with 0° and 180° phases were applied to inner and outer elements simultaneously, a multi-focal zone was generated in the axial direction. The total −6 dB DOF, i.e., sum of two −6 dB DOFs in the near and far field lobes, was 40% longer than that of the conventional single element transducer. The signal to noise ratio (SNR) was increased by about two times, especially in the far field. The point and cyst phantom simulation were conducted and their results were identical to that of the beam pattern simulation. Thus, the proposed scheme may be a potential method to improve the DOF and SNR in HFUI.
Collapse
|
30
|
High performance relaxor-based ferroelectric single crystals for ultrasonic transducer applications. SENSORS 2014; 14:13730-58. [PMID: 25076222 PMCID: PMC4178991 DOI: 10.3390/s140813730] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 07/18/2014] [Accepted: 07/18/2014] [Indexed: 01/21/2023]
Abstract
Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) have drawn much attention in the ferroelectric field because of their excellent piezoelectric properties and high electromechanical coupling coefficients (d33∼2000 pC/N, kt∼60%) near the morphotropic phase boundary (MPB). Ternary Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystals also possess outstanding performance comparable with PMN-PT single crystals, but have higher phase transition temperatures (rhombohedral to tetragonal Trt, and tetragonal to cubic Tc) and larger coercive field Ec. Therefore, these relaxor-based single crystals have been extensively employed for ultrasonic transducer applications. In this paper, an overview of our work and perspectives on using PMN-PT and PIN-PMN-PT single crystals for ultrasonic transducer applications is presented. Various types of single-element ultrasonic transducers, including endoscopic transducers, intravascular transducers, high-frequency and high-temperature transducers fabricated using the PMN-PT and PIN-PMN-PT crystals and their 2-2 and 1-3 composites are reported. Besides, the fabrication and characterization of the array transducers, such as phased array, cylindrical shaped linear array, high-temperature linear array, radial endoscopic array, and annular array, are also addressed.
Collapse
|
31
|
Abellard AP, Kuscer D, Grégoire JM, Lethiecq M, Malic B, Levassort F. Lead zirconate titanate-based thick films for high-frequency focused ultrasound transducers prepared by electrophoretic deposition. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:547-556. [PMID: 24569258 DOI: 10.1109/tuffc.2014.2938] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
An electrophoretic deposition (EPD) process with high deposition rate was used to fabricate a curved piezoelectric thick film devoted to high-frequency transducers for medical imaging. Niobium-doped lead zirconate titanate (PZTNb) powder was stabilized in ethanol to prepare a suspension with high zeta potential and low conductivity. A gold layer, pad-printed and fired on a curved porous PZT substrate, was used as the working electrode for the deposition of the PZTNb thick film. This substrate was chosen because it has the required properties (acoustic impedance and attenuation) to be used directly as a backing for the high-frequency transducer, leading to a simplified process for transducer assembly with this integrated structure. PZT-Nb thick films were also deposited by EPD on flat gold-coated alumina substrates as a reference. The thickness of the films was between 20 and 35 μm, and their electromechanical performance was comparable to standard PZT bulk ceramics with a thickness coupling factor of 48%. For the curved thick film, the thickness coupling factor was slightly lower. The corresponding integrated structure was used to fabricate a transducer with a center frequency of 40 MHz and an f-number of 2.8. It was integrated into a realtime ultrasound scanner and used to image human forearm skin; the resulting images showed, for the first time, the efficacy of the EPD process for these imaging applications.
Collapse
|
32
|
Aristizábal O, Mamou J, Ketterling JA, Turnbull DH. High-throughput, high-frequency 3-D ultrasound for in utero analysis of embryonic mouse brain development. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:2321-32. [PMID: 24035625 PMCID: PMC3834109 DOI: 10.1016/j.ultrasmedbio.2013.06.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Revised: 06/21/2013] [Accepted: 06/30/2013] [Indexed: 05/05/2023]
Abstract
With the emergence of the mouse as the predominant model system for studying mammalian brain development, in utero imaging methods are urgently required to analyze the dynamics of brain growth and patterning in mouse embryos. To address this need, we combined synthetic focusing with a high-frequency (38-MHz) annular-array ultrasound imaging system for extended depth-of-field, coded excitation for improved penetration and respiratory-gated transmit/receive. This combination allowed non-invasive in utero acquisition of motion-free 3-D data from individual embryos in approximately 2 min, and data from four or more embryos in a pregnant mouse in less than 30 min. Data were acquired from 148 embryos spanning 5 d of early to mid-gestational stages of brain development. The results indicated that brain anatomy and cerebral vasculature can be imaged with this system and that quantitative analyses of segmented cerebral ventricles can be used to characterize volumetric changes associated with mouse brain development.
Collapse
Affiliation(s)
- Orlando Aristizábal
- Kimmel Center for Biology and Medicine at the Skirball Institute of Biomolecular Medicine, New York University School of Medicine, New York, NY, USA
- Department of Radiology, New York University School of Medicine, New York, NY, USA
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA
| | - Jonathan Mamou
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA
| | - Jeffrey A. Ketterling
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA
- Correspondence to: Jeffrey A. Ketterling, PhD, Lizzi Center for Biomedical Engineering, Riverside Research, 156 William Street, New York, NY, USA 10038, and Daniel H. Turnbull, PhD, Skirball Institute of Biomolecular Medicine, New York University School of Medicine, 540 First Avenue, New York, NY, USA 10016, Tel: (212) 263-7262, Fax: (212) 263-8214,
| | - Daniel H. Turnbull
- Kimmel Center for Biology and Medicine at the Skirball Institute of Biomolecular Medicine, New York University School of Medicine, New York, NY, USA
- Department of Radiology, New York University School of Medicine, New York, NY, USA
- Correspondence to: Jeffrey A. Ketterling, PhD, Lizzi Center for Biomedical Engineering, Riverside Research, 156 William Street, New York, NY, USA 10038, and Daniel H. Turnbull, PhD, Skirball Institute of Biomolecular Medicine, New York University School of Medicine, 540 First Avenue, New York, NY, USA 10016, Tel: (212) 263-7262, Fax: (212) 263-8214,
| |
Collapse
|
33
|
Alibakhshi MA, Kracht JM, Cleveland RO, Filoux E, Ketterling JA. Single-shot measurements of the acoustic field of an electrohydraulic lithotripter using a hydrophone array. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:3176-3185. [PMID: 23654419 PMCID: PMC3663848 DOI: 10.1121/1.4795801] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2012] [Revised: 02/21/2013] [Accepted: 02/27/2013] [Indexed: 06/02/2023]
Abstract
Piezopolymer-based hydrophone arrays consisting of 20 elements were fabricated and tested for use in measuring the acoustic field from a shock-wave lithotripter. The arrays were fabricated from piezopolymer films and were mounted in a housing to allow submersion into water. The motivation was to use the array to determine how the shot-to-shot variability of the spark discharge in an electrohydraulic lithotripter affects the resulting focused acoustic field. It was found that the dominant effect of shot-to-shot variability was to laterally shift the location of the focus by up to 5 mm from the nominal acoustic axis of the lithotripter. The effect was more pronounced when the spark discharge was initiated with higher voltages. The lateral beamwidth of individual, instantaneous shock waves were observed to range from 1.5 mm to 24 mm. Due to the spatial variation of the acoustic field, the average of instantaneous beamwidths were observed to be 1 to 2 mm narrower than beamwidths determined from traditional single-point measurements that average the pressure measured at each location before computing beamwidth.
Collapse
Affiliation(s)
- Mohammad A Alibakhshi
- Department of Mechanical Engineering, Boston University, 110 Cummington Street, Boston, Massachusetts 02215, USA
| | | | | | | | | |
Collapse
|
34
|
Filoux E, Sampathkumar A, Chitnis PV, Aristizábal O, Ketterling JA. High-frequency annular array with coaxial illumination for dual-modality ultrasonic and photoacoustic imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2013; 84:053705. [PMID: 23742556 PMCID: PMC3676372 DOI: 10.1063/1.4804636] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This paper presents a combined ultrasound and photoacoustic (PA) imaging (PAI) system used to obtain high-quality, co-registered images of mouse-embryo anatomy and vasculature. High-frequency ultrasound (HFU, >20 MHz) is utilized to obtain high-resolution anatomical images of small animals while PAI provides high-contrast images of the vascular network. The imaging system is based on a 40 MHz, 5-element, 6 mm aperture annular-array transducer with a 800 μm diameter hole through its central element. The transducer was integrated in a cage-plate assembly allowing for a collimated laser beam to pass through the hole so that the optical and acoustic beams were collinear. The assembly was mounted on a two-axis, motorized stage to enable the simultaneous acquisition of co-registered HFU and PA volumetric data. Data were collected from all five elements in receive and a synthetic-focusing algorithm was applied in post-processing to beamform the data and increase the spatial resolution and depth-of-field (DOF) of the HFU and PA images. Phantom measurements showed that the system could achieve high-resolution images (down to 90 μm for HFU and 150 μm for PAI) and a large DOF of >8 mm. Volume renderings of a mouse embryo showed that the scanner allowed for visualizing morphologically precise anatomy of the entire embryo along with corresponding co-registered vasculature. Major head vessels, such as the superior sagittal sinus or rostral vein, were clearly identified as well as limb bud vasculature.
Collapse
Affiliation(s)
- Erwan Filoux
- Lizzi Center for Biomedical Engineering, Riverside Research, New York, New York 10038, USA
| | | | | | | | | |
Collapse
|
35
|
Jeong JS, Shung KK. Improved fabrication of focused single element P(VDF-TrFE) transducer for high frequency ultrasound applications. ULTRASONICS 2013; 53:455-458. [PMID: 23021238 PMCID: PMC3774315 DOI: 10.1016/j.ultras.2012.08.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2011] [Revised: 08/13/2012] [Accepted: 08/23/2012] [Indexed: 06/01/2023]
Abstract
We present an improved fabrication technique for the focused single element poly (vinylidene fluoride-trifluoroethylene) P(VDF-TrFE) transducer. In this work, a conductive epoxy for a backing layer was directly bonded to the 25μm thick P(VDF-TrFE) film and thus made it easy to conform the aperture of the P(VDF-TrFE) transducer. Two prototype focused P(VDF-TrFE) transducers with disk- and ring-type aperture were fabricated and their performance was evaluated using the UBM (Ultrasound Biomicroscopy) system with a wire phantom. All transducers had a spherically focused aperture with a low f-number (focal depth/aperture size=1). The center frequency of the disk-type P(VDF-TrFE) transducer was 23MHz and-6dB bandwidth was 102%. The ring-type P(VDF-TrFE) transducer had 20MHz center frequency and-6dB bandwidth of 103%. The measured pulse echo signal had reduced reverberation due to no additional adhesive layer between the P(VDF-TrFE) film and the backing layer. Hence, the proposed method is promising to fabricate a single element transducer using P(VDF-TrFE) film for high frequency applications.
Collapse
Affiliation(s)
- Jong Seob Jeong
- Department of Medical Biotechnology, Dongguk University-Seoul, Seoul 100-715, Republic of Korea.
| | | |
Collapse
|
36
|
Qiu W, Yu Y, Chabok HR, Liu C, Tsang FK, Zhou Q, Shung KK, Zheng H, Sun L. A flexible annular-array imaging platform for micro-ultrasound. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2013; 60:178-186. [PMID: 23287923 PMCID: PMC3738186 DOI: 10.1109/tuffc.2013.2548] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Micro-ultrasound is an invaluable imaging tool for many clinical and preclinical applications requiring high resolution (approximately several tens of micrometers). Imaging systems for micro-ultrasound, including single-element imaging systems and linear-array imaging systems, have been developed extensively in recent years. Single-element systems are cheaper, but linear-array systems give much better image quality at a higher expense. Annular-array-based systems provide a third alternative, striking a balance between image quality and expense. This paper presents the development of a novel programmable and real-time annular-array imaging platform for micro-ultrasound. It supports multi-channel dynamic beamforming techniques for large-depth-of-field imaging. The major image processing algorithms were achieved by a novel field-programmable gate array technology for high speed and flexibility. Real-time imaging was achieved by fast processing algorithms and high-speed data transfer interface. The platform utilizes a printed circuit board scheme incorporating state-of-the-art electronics for compactness and cost effectiveness. Extensive tests including hardware, algorithms, wire phantom, and tissue mimicking phantom measurements were conducted to demonstrate good performance of the platform. The calculated contrast-to-noise ratio (CNR) of the tissue phantom measurements were higher than 1.2 in the range of 3.8 to 8.7 mm imaging depth. The platform supported more than 25 images per second for real-time image acquisition. The depth-of-field had about 2.5-fold improvement compared to single-element transducer imaging.
Collapse
Affiliation(s)
- Weibao Qiu
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Filoux E, Mamou J, Moran CM, Pye SD, Ketterling JA. Correspondence - Characterization of the effective performance of a high-frequency annular-array-based imaging system using anechoic-pipe phantoms. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2012; 59:2825-30. [PMID: 23221233 PMCID: PMC3531879 DOI: 10.1109/tuffc.2012/2525] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
A resolution integral (RI) method based on anechoic- pipe, tissue-mimicking phantoms was used to compare the detection capabilities of high-frequency imaging systems based on a single-element transducer, a state-of-the-art 256-element linear array, or a 5-element annular array. All transducers had a central frequency of 40 MHz with similar conventionally measured axial and lateral resolutions (about 50 and 85 μm, respectively). Using the RI metric, the annular array achieved the highest performance (RI = 60), followed by the linear array (RI = 47), and the single-element transducer (RI = 24). Results showed that the RI metric could be used to efficiently quantify the effective transducer performance and compare the image quality of different systems.
Collapse
Affiliation(s)
- Erwan Filoux
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA
| | - Jonathan Mamou
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA
| | - Carmel M. Moran
- Center for Cardiovascular Science, Queen’s Medical Research Institute, University of Edinburgh, Edinburgh, UK
| | - Stephen D. Pye
- NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, UK
| | | |
Collapse
|
38
|
Ketterling JA, Filoux E. Synthetic-focusing strategies for real-time annular-array imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2012; 59:1830-9. [PMID: 22899130 PMCID: PMC3422783 DOI: 10.1109/tuffc.2012.2388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Annular arrays provide a means to achieve enhanced image quality with a limited number of elements. Synthetic-focusing (SF) strategies that rely on beamforming data from individual transmit-to-receive (TR) element pairs provide a means to improve image quality without specialized TR delay electronics. Here, SF strategies are examined in the context of high-frequency ultrasound (>15 MHz) annular arrays composed of five elements, operating at 18 and 38 MHz. Acoustic field simulations are compared with experimental data acquired from wire and anechoic-sphere phantoms, and the values of lateral beamwidth, SNR, contrast-to-noise ratio (CNR), and depth of field (DOF) are compared as a function of depth. In each case, data were acquired for all TR combinations (25 in total) and processed with SF using all 25 TR pairs and SF with the outer receive channels removed one by one. The results show that removing the outer receive channels led to an overall degradation of lateral resolution, an overall decrease in SNR, and did not reduce the DOF, although the DOF profile decreased in amplitude. The CNR was >1 and remained fairly constant as a function of depth, with a slight decrease in CNR for the case with just the central element receiving. The relative changes between the calculated and measured quantities were nearly identical for the 18- and 38-MHz arrays. B-mode images of the anechoic phantom and an in vivo mouse embryo using full SF with 25 TR pairs or reduced TR-pair approaches showed minimal qualitative difference.
Collapse
|
39
|
Lay HS, Simpson EA, Griffin G, Lockwood GR. High-frequency annular array fabrication using a flex circuit matching layer. ULTRASONIC IMAGING 2012; 34:196-204. [PMID: 22972915 DOI: 10.1177/0161734612456545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Fabricating arrays for high-frequency image applications such as ophthalmic imaging, intravascular imaging, and small animal imaging is challenging. For example, an array for intravascular imaging must be small enough to fit within the lumen of a catheter and inexpensive enough to be discarded after a single use. This article presents a new method for fabricating high-frequency annular arrays that is simple and inexpensive. The annular array elements are defined by the electrode pattern on a back surface of a polyimide quarter-wavelength matching layer that is glued to the front face of a ceramic transducer substrate (PZT5H). Electrical losses associated with bonding the matching layer to the transducer substrate are reduced by fabricating a second set of electrodes on the transducer substrate and then bonding the substrates using an anisotropic conductive epoxy. The feasibility of this technique was established by fabricating a seven-element, 20-MHz, 5-mm diameter annular array. The prototype array produced a pulse with a -6-dB factional bandwidth of 50%, an insertion loss of 22 dB, and secondary lobes in the radiation pattern at f/2 that decreased to -65 dB with respect to the main lobe with a peak amplitude of -53 dB.
Collapse
Affiliation(s)
- Holly S Lay
- Sonavation, Inc., Palm Beach Gardens, FL, USA.
| | | | | | | |
Collapse
|
40
|
Qiu W, Yu Y, Tsang F, Sun L. An FPGA-based open platform for ultrasound biomicroscopy. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2012; 59:1432-1442. [PMID: 22828839 DOI: 10.1109/tuffc.2012.2344] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Ultrasound biomicroscopy (UBM) has been extensively applied to preclinical studies in small animal models. Individual animal study is unique and requires different utilization of the UBM system to accommodate different transducer characteristics, data acquisition strategies, signal processing, and image reconstruction methods. There is a demand for a flexible and open UBM platform to allow users to customize the system for various studies and have full access to experimental data. This paper presents the development of an open UBM platform (center frequency 20 to 80 MHz) for various preclinical studies. The platform design was based on a field-programmable gate array (FPGA) embedded in a printed circuit board to achieve B-mode imaging and directional pulsed-wave Doppler. Instead of hardware circuitry, most functions of the platform, such as filtering, envelope detection, and scan conversion, were achieved by FPGA programs; thus, the system architecture could be easily modified for specific applications. In addition, a novel digital quadrature demodulation algorithm was implemented for fast and accurate Doppler profiling. Finally, test results showed that the platform could offer a minimum detectable signal of 25 μV, allowing a 51 dB dynamic range at 47 dB gain, and real-time imaging at more than 500 frames/s. Phantom and in vivo imaging experiments were conducted and the results demonstrated good system performance.
Collapse
Affiliation(s)
- Weibao Qiu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | | | | | | |
Collapse
|
41
|
Liu C, Djuth F, Li X, Chen R, Zhou Q, Shung KK. Micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular array. ULTRASONICS 2012; 52:497-502. [PMID: 22119324 PMCID: PMC3774318 DOI: 10.1016/j.ultras.2011.11.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2011] [Revised: 10/21/2011] [Accepted: 11/03/2011] [Indexed: 05/07/2023]
Abstract
This paper reports the design, fabrication, and performance of miniature micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular arrays. The PMN-PT single crystal 1-3 composites were made with micromachining techniques. The area of a single crystal pillar was 9×9 μm. The width of the kerf among pillars was ∼5 μm and the kerfs were filled with a polymer. The composite thickness was 25 μm. A six-element annular transducer of equal element area of 0.2 mm(2) with 16 μm kerf widths between annuli was produced. The aperture size the array transducer is about 1.5 mm in diameter. A novel electrical interconnection strategy for high density array elements was implemented. After the transducer was attached to the electric connection board and packaged, the array transducer was tested in a pulse/echo arrangement, whereby the center frequency, bandwidth, two-way insertion loss (IL), and cross talk between adjacent elements were measured for each annulus. The center frequency was 50 MHz and -6 dB bandwidth was 90%. The average insertion loss was 19.5 dB at 50 MHz and the crosstalk between adjacent elements was about -35 dB. The micromachining techniques described in this paper are promising for the fabrication of other types of high frequency transducers, e.g. 1D and 2D arrays.
Collapse
Affiliation(s)
- Changgeng Liu
- Geospace Research, Inc., 525 South Douglas Street, Suite 290, El Segundo, CA, USA.
| | | | | | | | | | | |
Collapse
|
42
|
Silverman RH, Ketterling JA, Mamou J, Lloyd HO, Filoux E, Coleman DJ. Pulse-encoded ultrasound imaging of the vitreous with an annular array. Ophthalmic Surg Lasers Imaging Retina 2011; 43:82-6. [PMID: 21902166 DOI: 10.3928/15428877-20110901-03] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2011] [Accepted: 08/12/2011] [Indexed: 11/20/2022]
Abstract
The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved 20-MHz five-element annular array ultrasound transducer, implemented a synthetic-focusing algorithm to extend the depth-of-field, and used a pulse-encoding strategy to increase sensitivity. The authors evaluated a human subject with a recent posterior vitreous detachment and compared the annular array with conventional 10-MHz ultrasound and spectral-domain optical coherence tomography. With synthetic focusing and chirp pulse-encoding, the array allowed visualization of the formed and fluid components of the vitreous with improved sensitivity and resolution compared with the conventional B-scan. Although optical coherence tomography allowed assessment of the posterior vitreoretinal interface, the ultrasound array allowed evaluation of the entire vitreous body.
Collapse
Affiliation(s)
- Ronald H Silverman
- Department of Ophthalmology, Columbia University Medical Center, New York, NY 10032, USA.
| | | | | | | | | | | |
Collapse
|
43
|
Passler K, Nuster R, Gratt S, Burgholzer P, Paltauf G. Piezoelectric annular array for large depth of field photoacoustic imaging. BIOMEDICAL OPTICS EXPRESS 2011; 2:2655-64. [PMID: 21991555 PMCID: PMC3184874 DOI: 10.1364/boe.2.002655] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2011] [Revised: 08/01/2011] [Accepted: 08/04/2011] [Indexed: 05/04/2023]
Abstract
A piezoelectric detection system consisting of an annular array is investigated for large depth of field photoacoustic imaging. In comparison to a single ring detection system, X-shaped imaging artifacts are suppressed. Sensitivity and image resolution studies are performed in simulations and in experiments and compared to a simulated spherical detector. In experiment an eight ring detection systems offers an extended depth of field over a range of 16 mm with almost constant lateral resolution.
Collapse
Affiliation(s)
- K. Passler
- Department of Physics, Karl-Franzens-Universitaet Graz, Graz, Austria
| | - R. Nuster
- Department of Physics, Karl-Franzens-Universitaet Graz, Graz, Austria
| | - S. Gratt
- Department of Physics, Karl-Franzens-Universitaet Graz, Graz, Austria
| | - P. Burgholzer
- Department of sensor technology, Recendt, Linz, Austria
| | - G. Paltauf
- Department of Physics, Karl-Franzens-Universitaet Graz, Graz, Austria
| |
Collapse
|
44
|
Filoux E, Mamou J, Aristizábal O, Ketterling JA. Characterization of the spatial resolution of different high-frequency imaging systems using a novel anechoic-sphere phantom. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:994-1005. [PMID: 21622055 DOI: 10.1109/tuffc.2011.1900] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The spatial resolution of high-frequency ultrasound (HFU, >20 MHz) imaging systems is usually determined using wires perpendicular to the beam. Recently, two tissue-mimicking phantoms (TMPs) were developed to estimate three-dimensional (3-D) resolution. Each TMP consists of nine 1-cm-wide slabs of tissue-mimicking material containing randomly distributed anechoic spheres. All anechoic spheres in one slab have the same dimensions, and their diameter is increased from 0.1 mm in the first slab to 1.09 mm in the last. The scattering background for one set of slabs was fabricated using 3.5-μm glass beads; the second set used 6.4-μm glass beads. The ability of a HFU system to detect these spheres against a speckle background provides a realistic estimation of its 3-D spatial resolution. In the present study, these TMPs were used with HFU systems using single-element transducers, linear arrays, and annular arrays. The TMPs were immersed in water and each slab was scanned using two commercial imaging systems and a custom HFU system based on a 5-element annular array. The annular array had a nominal center frequency of 40 MHz, a focal length of 12 mm, and a total aperture of 6 mm. A synthetic-focusing algorithm was used to form images with an increased depth-of-field. The penetration depth was increased by using a linear-chirp signal spanning 15 to 65 MHz over 4 μs. Results obtained with the custom system were compared with those of the commercial systems (40-MHz probes) in terms of sphere detection, i.e., 3-D spatial resolution, and contrast-to-noise ratio (CNR). Resulting B-mode images indicated that only the linear-array transducer failed to clearly resolve the 0.2-mm spheres, which showed that the 3-D spatial resolution of the single-element and annular-array transducers was superior to that of the linear array. The single-element transducer could only detect these spheres over a narrow 1.5 mm depth-of-field, whereas the annular array was able to detect them to depths of at least 7 mm. For any size of the anechoic spheres, the annular array excited by a chirp-coded signal provided images of the highest contrast, with a maximum CNR of 1.8 at the focus, compared with 1.3 when using impulse excitation and 1.6 with the single-element transducer and linear array. This imaging configuration also provided CNRs above 1.2 over a wide depth range of 8 mm, whereas CNRs would quickly drop below 1 outside the focal zone of the other configurations.
Collapse
Affiliation(s)
- Erwan Filoux
- Riverside Research, F L Lizzi Center for Biomedical Engineering, New York, NY, USA.
| | | | | | | |
Collapse
|
45
|
Filoux E, Mamou J, Aristizábal O, Ketterling JA. Characterization of the spatial resolution of different high-frequency imaging systems using a novel anechoic-sphere phantom. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:1628-40. [PMID: 21622055 PMCID: PMC3105360 DOI: 10.1109/tuffc.2011.1990] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The spatial resolution of high-frequency ultrasound (HFU, >20 MHz) imaging systems is usually determined using wires perpendicular to the beam. Recently, two tissue-mimicking phantoms (TMPs) were developed to estimate three-dimensional (3-D) resolution. Each TMP consists of nine 1-cm-wide slabs of tissue-mimicking material containing randomly distributed anechoic spheres. All anechoic spheres in one slab have the same dimensions, and their diameter is increased from 0.1 mm in the first slab to 1.09 mm in the last. The scattering background for one set of slabs was fabricated using 3.5-μm glass beads; the second set used 6.4-μm glass beads. The ability of a HFU system to detect these spheres against a speckle background provides a realistic estimation of its 3-D spatial resolution. In the present study, these TMPs were used with HFU systems using single-element transducers, linear arrays, and annular arrays. The TMPs were immersed in water and each slab was scanned using two commercial imaging systems and a custom HFU system based on a 5-element annular array. The annular array had a nominal center frequency of 40 MHz, a focal length of 12 mm, and a total aperture of 6 mm. A synthetic-focusing algorithm was used to form images with an increased depth-of-field. The penetration depth was increased by using a linear-chirp signal spanning 15 to 65 MHz over 4 μs. Results obtained with the custom system were compared with those of the commercial systems (40-MHz probes) in terms of sphere detection, i.e., 3-D spatial resolution, and contrast-to-noise ratio (CNR). Resulting B-mode images indicated that only the linear-array transducer failed to clearly resolve the 0.2-mm spheres, which showed that the 3-D spatial resolution of the single-element and annular-array transducers was superior to that of the linear array. The single-element transducer could only detect these spheres over a narrow 1.5 mm depth-of-field, whereas the annular array was able to detect them to depths of at least 7 mm. For any size of the anechoic spheres, the annular array excited by a chirp-coded signal provided images of the highest contrast, with a maximum CNR of 1.8 at the focus, compared with 1.3 when using impulse excitation and 1.6 with the single-element transducer and linear array. This imaging configuration also provided CNRs above 1.2 over a wide depth range of 8 mm, whereas CNRs would quickly drop below 1 outside the focal zone of the other configurations.
Collapse
Affiliation(s)
- Erwan Filoux
- Riverside Research, F L Lizzi Center for Biomedical Engineering, New York, NY, USA.
| | | | | | | |
Collapse
|
46
|
Zhou Q, Lau S, Wu D, Shung KK. Piezoelectric films for high frequency ultrasonic transducers in biomedical applications. PROGRESS IN MATERIALS SCIENCE 2011; 56:139-174. [PMID: 21720451 PMCID: PMC3123890 DOI: 10.1016/j.pmatsci.2010.09.001] [Citation(s) in RCA: 124] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Piezoelectric films have recently attracted considerable attention in the development of various sensor and actuator devices such as nonvolatile memories, tunable microwave circuits and ultrasound transducers. In this paper, an overview of the state of art in piezoelectric films for high frequency transducer applications is presented. Firstly, the basic principles of piezoelectric materials and design considerations for ultrasound transducers will be introduced. Following the review, the current status of the piezoelectric films and recent progress in the development of high frequency ultrasonic transducers will be discussed. Then details for preparation and structure of the materials derived from piezoelectric thick film technologies will be described. Both chemical and physical methods are included in the discussion, namely, the sol-gel approach, aerosol technology and hydrothermal method. The electric and piezoelectric properties of the piezoelectric films, which are very important for transducer applications, such as permittivity and electromechanical coupling factor, are also addressed. Finally, the recent developments in the high frequency transducers and arrays with piezoelectric ZnO and PZT thick film using MEMS technology are presented. In addition, current problems and further direction of the piezoelectric films for very high frequency ultrasound application (up to GHz) are also discussed.
Collapse
Affiliation(s)
- Qifa Zhou
- NIH Resource Center for Medical Ultrasonic Transducer Technology, and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, United States
| | - Sienting Lau
- NIH Resource Center for Medical Ultrasonic Transducer Technology, and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, United States
| | - Dawei Wu
- NIH Resource Center for Medical Ultrasonic Transducer Technology, and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, United States
| | - K. Kirk Shung
- NIH Resource Center for Medical Ultrasonic Transducer Technology, and Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, United States
| |
Collapse
|
47
|
Chabok HR, Cannata JM, Kim HH, Williams JA, Park J, Shung KK. A high-frequency annular-array transducer using an interdigital bonded 1-3 composite. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:206-14. [PMID: 21244988 PMCID: PMC3056280 DOI: 10.1109/tuffc.2011.1787] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This paper reports the design, fabrication, and characterization of a 1-3 composite annular-array transducer. An interdigital bonded (IB) 1-3 composite was prepared using two IB operations on a fine-grain piezoelectric ceramic. The final composite had 19-μm-wide posts separated by 6-μm-wide polymer kerfs. A novel method to remove metal electrodes from polymer portions of the 1-3 composite was established to eliminate the need for patterning and aligning the electrode on the composite to the electrodes on a flexible circuit. Unloaded epoxy was used for both the matching and backing layers and a flexible circuit was used for interconnect. A prototype array was successfully fabricated and tested. The results were in reasonable agreement with those predicted by a circuit-analogous model. The average center frequency estimated from the measured pulse-echo responses of array elements was 33.5 MHz and the -6-dB fractional bandwidth was 57%. The average insertion loss recorded was 14.3 dB, and the maximum crosstalk between the nearest-neighbor elements was less than -37 dB. Images of a wire phantom and excised porcine eye were obtained to show the capabilities of the array for high-frequency ultrasound imaging.
Collapse
Affiliation(s)
- Hamid Reza Chabok
- NIH Resource Center for Medical Ultrasonic Transducer Technology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.
| | | | | | | | | | | |
Collapse
|
48
|
Torbatian Z, Adamson R, Bance M, Brown JA. A split-aperture transmit beamforming technique with phase coherence grating lobe suppression. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2010; 57:2588-2595. [PMID: 21041146 DOI: 10.1109/tuffc.2010.1725] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A small element-to-element pitch (~.5λ) is conventionally required for phased array ultrasound transducers to avoid large grating lobes. This constraint can introduce many fabrication difficulties, particularly in the development of highfrequency phased arrays at operating frequencies greater than 30 MHz. In this paper, a new transmit beamforming technique along with sign coherence factor (SCF) receive beamforming is proposed to suppress grating lobes in large-pitch phased-array transducers. It is based on splitting the transmit aperture (N elements) into N/K transmit elements and receive beamforming on all N elements to reduce the temporal length of the transmit grating lobe signal. Therefore, the use of synthetic aperture beamforming, which can introduce relative phase distortions between the echoes received over many transmit events, can be avoided. After each transmit-receive event, the received signals are weighted by the calculated SCF to suppress the grating lobes. After pulsing all sub-apertures, the RF signals are added to generate one line of the image. Simulated 2-way radiation patterns for different K values show that grating lobes can be suppressed significantly at different steering angles. Grating lobes can be suppressed by approximately 20 dB with K = 2 at steering angles greater than 25° and an element pitch greater than 0.75λ. A technique for determining the optimal transmit sub-apertures has been developed.
Collapse
|
49
|
Jiang Y, Harrison T, Ranasinghesagara J, Zemp RJ. Photoacoustic and high-frequency power Doppler ultrasound biomicroscopy: a comparative study. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:056008. [PMID: 21054102 DOI: 10.1117/1.3491126] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Both photoacoustic imaging and power Doppler ultrasound are capable of producing images of the vasculature of living subjects, however, the contrast mechanisms of the two modalities are very different. We present a quantitative and objective comparison of the two methods using phantom data, highlighting relative merits and shortcomings. An imaging system for combined photoacoustic and high-frequency power Doppler ultrasound microscopy is presented. This system uses a swept-scan 25-MHz ultrasound transducer with confocal dark-field laser illumination optics. A pulse-sequencer enables ultrasonic and laser pulses to be interlaced so that photoacoustic and power Doppler ultrasound images can be coregistered. Experiments are performed on flow phantoms with various combinations of vessel size, flow velocity, and optical wavelength. For the task of blood volume detection, power Doppler is seen to be advantageous for large vessels and high flow speeds. For small vessels with low flow speeds, photoacoustic imaging is seen to be more effective than power Doppler at the detection of blood as quantified by receiver operating characteristic analysis. A combination of the two modes could provide improved estimates of fractional blood volume in comparison with either mode used alone.
Collapse
Affiliation(s)
- Yan Jiang
- University of Alberta, Department of Electrical and Computer Engineering, Edmonton, Alberta T6G 2V4, Canada.
| | | | | | | |
Collapse
|
50
|
Abstract
A detailed review is given of the application of high-frequency ultrasound (HFUS) at frequencies of 20 MHz and above for high-resolution, cross-sectional imaging of biological soft tissue. The state of the art of HFUS imaging systems is discussed with respect to the underlying engineering concepts, system designs, and available transducer technology. Furthermore, the dependency of the spatial resolution on the system's parameters is analysed. Skin imaging, eye imaging, small animal imaging for preclinical research, and intravascular ultrasound in coronary arteries for arteriosclerotic disease diagnostics are presented as examples for the application of HFUS imaging in medical diagnostics. It is shown that, in the frame of the indicated applications, ultrasound in the frequency range 20-100MHz gives a good compromise between the contrary demands for a good spatial resolution and a sufficiently large penetration depth of ultrasound waves into the tissue. Scanning schemes for the imaging of tissue morphology are considered, including spatial compounding as a multidirectional imaging technique.
Collapse
Affiliation(s)
- M Vogt
- Department of Electrical Engineering and Information Technology, Institute of High-Frequency Engineering, Ruhr-Universität Bochum, Bochum, Germany.
| | | | | | | |
Collapse
|