1
|
Boyd S, Murphy CJ, Snyman L. Single-use vs. reusable flexible bronchoscopes for airway management and in critical care: a narrative review. Anaesthesia 2024. [PMID: 39344667 DOI: 10.1111/anae.16430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/08/2024] [Indexed: 10/01/2024]
Abstract
INTRODUCTION Flexible bronchoscopes have become essential in the operating theatre environment and in critical care. This narrative review compared single-use and reusable flexible bronchoscopes with a focus on safety, efficacy, cost-effectiveness and environmental impact. METHODS We searched MEDLINE, Embase and PubMed databases for studies related to flexible bronchoscopes for airway management or use in critical care. Human or animal studies of any design assessing single-use and reusable flexible bronchoscopes were included and qualitatively synthesised. We also searched manufacturer websites for relevant data. RESULTS We included 52 studies and data from six manufacturer websites. There was mixed evidence for safety, and data on usability also showed significant heterogeneity, with different parameters, manufacturers and models examined. Neither single-use nor reusable flexible bronchoscopes appeared convincingly superior to the other for safety or usability. Cost analyses showed that the rate of use of flexible bronchoscopes per year, along with several other factors, affects cost-effectiveness for each institution, though the risk of cross-contamination is an advantage of single-use devices. However, sufficient evidence on the rate of bronchoscopy-induced infection in the operating theatre and critical care environment is lacking. Due to the risk of cross-contamination, single-use flexible bronchoscopes must be sterilised or incinerated after use, and completely recyclable single-use models are not currently available. CONCLUSIONS Further research is required on safety, usability and life cycle assessment in the operating theatre and critical care environment, as well as on the rate of bronchoscopy-induced infection. Future comparative studies, including new manufacturers and designs, may lend further insights.
Collapse
Affiliation(s)
- Sean Boyd
- Department of Anaesthesiology, Tallaght University Hospital, Tallaght, Dublin, Ireland
| | - Ciara J Murphy
- Department of Anaesthesiology, Tallaght University Hospital, Tallaght, Dublin, Ireland
| | - Lindi Snyman
- Department of Anaesthesiology, Tallaght University Hospital, Tallaght, Dublin, Ireland
| |
Collapse
|
2
|
Grimm DR, Halagur AS, Ayoub N. Complications Associated with AMBU™ Scope Use: An FDA MAUDE Analysis. Otolaryngol Head Neck Surg 2024. [PMID: 38988303 DOI: 10.1002/ohn.898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 06/21/2024] [Accepted: 06/29/2024] [Indexed: 07/12/2024]
Abstract
Ambu® aScope™ is a disposable flexible videoscope used for a wide range of medical procedures. However, adverse events associated with this device can occur. The Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database was explored for patient-related adverse events associated with Ambu® aScope™ use between January 1, 2000 and December 15, 2023. Search terms included "Ambu" and "Ascope." Thirty unique adverse events were identified. Twenty-one of the events were associated with patient injury, and 9 with device malfunction. Eight patient-reported problems were documented as foreign bodies, 3 events as airway obstruction, desaturation, or hypoxic events, and 1 event as anxiety/cardiac arrest. The remaining 18 reported insufficient information other than associated with patient injury. We found that Ambu® aScope™ flexible nasolaryngoscopes and bronchoscopes are a common and effective tool for airway evaluations that may infrequently serve as a rare form of foreign body with potentially life-threatening consequences.
Collapse
Affiliation(s)
- David R Grimm
- Department of Otolaryngology-Head and Neck Surgery, Stanford University School of Medicine, Palo Alto, California, USA
| | - Akash S Halagur
- Department of Otolaryngology-Head and Neck Surgery, Stanford University School of Medicine, Palo Alto, California, USA
| | - Noel Ayoub
- Department of Otolaryngology-Head and Neck Surgery, Division of Rhinology and Skull Base Surgery, Mass Eye and Ear, Boston, Massachusetts, USA
| |
Collapse
|
3
|
Wayne MT, Valley TS, Arenberg DA, De Cardenas J, Prescott HC. Temporal Trends and Variation in Bronchoscopy Use for Acute Respiratory Failure in the United States. Chest 2023; 163:128-138. [PMID: 36007595 PMCID: PMC9859725 DOI: 10.1016/j.chest.2022.08.2210] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 07/26/2022] [Accepted: 08/10/2022] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND National data on bronchoscopy for the evaluation of acute respiratory failure are lacking, and the limited available data suggest wide variation in use. RESEARCH QUESTION How commonly is bronchoscopy performed among hospitalizations with acute respiratory failure? How has use changed over time and across hospitals? STUDY DESIGN AND METHODS This was an observational cohort study of adult hospitalizations (2012-2018) treated with invasive mechanical ventilation (IMV) using the National Inpatient Sample, which represents 97% of all hospitalizations in the United States. We measured the proportion of hospitalizations treated with IMV who underwent bronchoscopy and assessed trends in bronchoscopy use over time. Multilevel linear regression models were used to quantify hospital-level variation, adjusting for differences in patient and hospital characteristics. RESULTS We identified 6,101,070 IMV-treated hospitalizations (2012-2018), of whom 609,405 underwent bronchoscopy; among hospitalizations receiving bronchoscopy, mean age was 61 years, 41.8% were women, and in-hospital mortality was 30.8%. The percentage of IMV-treated hospitalizations receiving bronchoscopy increased from 9.5% (95% CI, 9.1%-9.9%) in 2012 to 10.8% (95% CI, 10.4%-11.2%) in 2018 (P < .001 for difference). In 2018, bronchoscopy use varied from 0% to 57.1% among 1,787 hospitals, and in multilevel models adjusted for patient and hospital characteristics, 16.0% of the variation was explained at the hospital level. The median OR was 2.13 (95% CI, 2.05-2.21), indicating 113% increased odds of receiving bronchoscopy if moving from a lower-use to a higher-use hospital. INTERPRETATION Bronchoscopy use among hospitalizations treated with IMV has increased over time. The large variation in use of bronchoscopy across hospitals suggests potentially unwarranted practice variation and need for further studies to clarify which patients benefit from bronchoscopy.
Collapse
Affiliation(s)
- Max T Wayne
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ann Arbor, MI.
| | - Thomas S Valley
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ann Arbor, MI; VA Center for Clinical Management Research, Ann Arbor, MI
| | - Douglas A Arenberg
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ann Arbor, MI
| | - Jose De Cardenas
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ann Arbor, MI; Section of Thoracic Surgery, Department of Surgery, University of Michigan, Ann Arbor, MI
| | - Hallie C Prescott
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Ann Arbor, MI; VA Center for Clinical Management Research, Ann Arbor, MI
| |
Collapse
|
4
|
Endlich Y, Hore PJ, Baker PA, Beckmann LA, Bradley WP, Chan KLE, Chapman GA, Jephcott CGA, Kruger PS, Newton A, Roessler P. Updated guideline on equipment to manage difficult airways: Australian and New Zealand College of Anaesthetists. Anaesth Intensive Care 2022; 50:430-446. [PMID: 35722809 DOI: 10.1177/0310057x221082664] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The Australian and New Zealand College of Anaesthetists (ANZCA) recently reviewed and updated the guideline on equipment to manage a difficult airway. An ANZCA-established document development group, which included representatives from the Australasian College for Emergency Medicine and the College of Intensive Care Medicine of Australia and New Zealand, performed the review, which is based on expert consensus, an extensive literature review, and bi-nationwide consultation. The guideline (PG56(A) 2021, https://www.anzca.edu.au/getattachment/02fe1a4c-14f0-4ad1-8337-c281d26bfa17/PS56-Guideline-on-equipment-to-manage-difficult-airways) is accompanied by a detailed background paper (PG56(A)BP 2021, https://www.anzca.edu.au/getattachment/9ef4cd97-2f02-47fe-a63a-9f74fa7c68ac/PG56(A)BP-Guideline-on-equipment-to-manage-difficult-airways-Background-Paper), from which the current recommendations are reproduced on behalf of, and with the permission of, ANZCA. The updated 2021 guideline replaces the 2012 version and aims to provide an updated, objective, informed, transparent, and evidence-based review of equipment to manage difficult airways.
Collapse
Affiliation(s)
- Yasmin Endlich
- Department of Anaesthesia and Acute Pain Medicine, Royal Adelaide Hospital, Adelaide, Australia.,Department of Paediatric Anaesthesia, Women's and Children's Hospital, North Adelaide, Australia.,Faculty of Anaesthesia, University of Adelaide, Adelaide, Australia
| | - Phillipa J Hore
- Department of Anaesthesia and Acute Pain Medicine, St Vincent's Hospital, Melbourne, Australia
| | - Paul A Baker
- Department of Anaesthesiology, University of Auckland, Auckland, New Zealand.,Department of Anaesthesia, Starship Children's Hospital, Auckland, New Zealand
| | - Linda A Beckmann
- Department of Anaesthesia and Acute Pain Medicine, Royal Brisbane and Women's Hospital, Herston, Australia
| | - William P Bradley
- Department of Anaesthesia and Perioperative Medicine, The Alfred, Melbourne, Australia.,Faculty of Anaesthesia, Monash University, Melbourne, Australia
| | - Kah L E Chan
- Department of Anaesthesia and Acute Pain Medicine, Royal Brisbane and Women's Hospital, Herston, Australia
| | - Gordon A Chapman
- Department of Anaesthesia, Royal Perth Hospital, Perth, Australia.,Faculty of Anaesthesia, University of Western Australia, Perth, Australia
| | | | - Peter S Kruger
- Department of Intensive Care Medicine, Princess Alexandra Hospital, Brisbane, Australia
| | - Alastair Newton
- Department of Emergency Medicine, The Prince Charles Hospital, Brisbane, Australia.,Retrieval Services Queensland, Brisbane, Australia
| | - Peter Roessler
- Safety and Advocacy Unit, Australian and New Zealand College of Anaesthetists, Melbourne, Australia
| |
Collapse
|
5
|
Ho E, Wagh A, Hogarth K, Murgu S. Single-Use and Reusable Flexible Bronchoscopes in Pulmonary and Critical Care Medicine. Diagnostics (Basel) 2022; 12:174. [PMID: 35054345 PMCID: PMC8775174 DOI: 10.3390/diagnostics12010174] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 01/08/2022] [Accepted: 01/10/2022] [Indexed: 02/04/2023] Open
Abstract
Flexible bronchoscopy plays a critical role in both diagnostic and therapeutic management of a variety of pulmonary disorders in the bronchoscopy suite and the intensive care unit. In the set-ting of the ongoing viral pandemic, single-use flexible bronchoscopes (SUFB) have garnered attention as various professional pulmonary societies have released guidelines regarding uses for SUFB given the concern for risk of viral transmission when using reusable flexible bronchoscopes (RFB). In addition to offering sterility, SUFBs are portable, easily accessible, and may be more cost-effective than RFB when considering the potential costs of treating bronchoscopy-related infections. Furthermore, since SUFBs are one time use, they do not require reprocessing after use, and therefore may translate to reduced cleaning and storage costs. Despite these advantages, RFBs are still routinely used to perform advanced diagnostic and therapeutic bronchoscopic procedures given the need for optimal maneuverability, handling, angle of deflection, image quality, and larger channel size for passing of ancillary instruments. Here, we review the published evidence on the applications of single-use and reusable bronchoscopes in bronchoscopy suites and intensive care units. Specifically, we will discuss the advantages and disadvantages of these devices as pertinent to fundamental, advanced, and therapeutic bronchoscopic interventions.
Collapse
Affiliation(s)
- Elliot Ho
- Section of Pulmonary and Critical Care Medicine/Interventional Pulmonology, Department of Medicine, Loma Linda University, Loma Linda, CA 92354, USA
| | - Ajay Wagh
- Section of Pulmonary and Critical Care Medicine/Interventional Pulmonology, Department of Medicine, The University of Chicago, Chicago, IL 60637, USA; (A.W.); (K.H.); (S.M.)
| | - Kyle Hogarth
- Section of Pulmonary and Critical Care Medicine/Interventional Pulmonology, Department of Medicine, The University of Chicago, Chicago, IL 60637, USA; (A.W.); (K.H.); (S.M.)
| | - Septimiu Murgu
- Section of Pulmonary and Critical Care Medicine/Interventional Pulmonology, Department of Medicine, The University of Chicago, Chicago, IL 60637, USA; (A.W.); (K.H.); (S.M.)
| |
Collapse
|
6
|
Sampsonas F, Kakoullis L, Karampitsakos T, Papaioannou O, Katsaras M, Papachristodoulou E, Kyriakou G, Bellou A, Tzouvelekis A. Bronchoscopy during the COVID-19 pandemic: effect on current practices and strategies to reduce procedure-associated transmission. Expert Rev Respir Med 2021; 15:773-779. [PMID: 33798401 DOI: 10.1080/17476348.2021.1913058] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Introduction: Bronchoscopy and related procedures have unambiguously been affected during the Corona Virus Disease 2019 (COVID-19) pandemic caused by Severe Acute Respiratory Syndrome-Corona Virus-2 (SARS COV-2). Ordinary bronchoscopy practices and lung cancer services might have changed over this pandemic and for the years to come.Areas covered: This manuscript summarizes the utility of bronchoscopy in COVID-19 patients, and the impact of the pandemic in lung cancer diagnostic services, in view of possible viral spread during these We conducted a literature review of articles published in PubMed/Medline from inception to November 5th, 2020 using relevant terms.Expert opinion: Without doubt this pandemic has changed the way bronchoscopy and related procedures are being performed. Mandatory universal personal protective equipment, pre-bronchoscopy PCR tests, dedicated protective barriers and disposable bronchoscopes might be the safest and simpler way to perform even the most complicated procedures.
Collapse
Affiliation(s)
- Fotios Sampsonas
- Respiratory Medicine Department, Internal Medicine Division, University Hospital of Patras, Patras, Greece
| | - Loukas Kakoullis
- Respiratory Medicine Department, Internal Medicine Division, University Hospital of Patras, Patras, Greece
| | - Theodoros Karampitsakos
- Respiratory Medicine Department, Internal Medicine Division, University Hospital of Patras, Patras, Greece
| | - Ourania Papaioannou
- Respiratory Medicine Department, Internal Medicine Division, University Hospital of Patras, Patras, Greece
| | - Matthaios Katsaras
- Respiratory Medicine Department, Internal Medicine Division, University Hospital of Patras, Patras, Greece
| | | | | | - Aggeliki Bellou
- Respiratory Medicine Department, Internal Medicine Division, University Hospital of Patras, Patras, Greece
| | - Argyrios Tzouvelekis
- Respiratory Medicine Department, Internal Medicine Division, University Hospital of Patras, Patras, Greece
| |
Collapse
|
7
|
Matek J, Kolek F, Klementova O, Michalek P, Vymazal T. Optical Devices in Tracheal Intubation-State of the Art in 2020. Diagnostics (Basel) 2021; 11:diagnostics11030575. [PMID: 33810158 PMCID: PMC8004982 DOI: 10.3390/diagnostics11030575] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 03/15/2021] [Accepted: 03/18/2021] [Indexed: 12/28/2022] Open
Abstract
The review article is focused on developments in optical devices, other than laryngoscopes, in airway management and tracheal intubation. It brings information on advantages and limitations in their use, compares different devices, and summarizes benefits in various clinical settings. Supraglottic airway devices may be used as a conduit for fiberscope-guided tracheal intubation mainly as a rescue plan in the scenario of difficult or failed laryngoscopy. Some of these devices offer the possibility of direct endotracheal tube placement. Hybrid devices combine the features of two different intubating tools. Rigid and semi-rigid optical stylets represent another option in airway management. They offer benefits in restricted mouth opening and may be used also for retromolar intubation. Awake flexible fiberoptic intubation has been a gold standard in predicted difficult laryngoscopy for decades. Modern flexible bronchoscopes used in anesthesia and intensive care are disposable devices and contain optical lenses instead of fibers. Endotracheal tubes with an incorporated optics are used mainly in thoracic anesthesia for lung separation. They are available in double-lumen and single-lumen versions. They offer a benefit of direct view to the carina and do not require flexible fiberscope for their correct placement.
Collapse
Affiliation(s)
- Jan Matek
- 1st Department of Surgery—Department of Abdominal, Thoracic Surgery and Traumatology, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, 12800 Prague, Czech Republic;
- Medical Faculty, Masaryk University, 62500 Brno, Czech Republic
| | - Frantisek Kolek
- Department of Anesthesiology and Intensive Medicine, University Hospital Motol, V Úvalu 84, 15000 Praha, Czech Republic;
| | - Olga Klementova
- Department of Anesthesiology and Intensive Medicine, University Hospital Olomouc, I.P. Pavlova 185, Nová Ulice, 77900 Olomouc, Czech Republic;
| | - Pavel Michalek
- Department of Anesthesiology and Intensive Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital, U Nemocnice 499/2, 12808 Praha, Czech Republic;
- Department of Anaesthesia, Antrim Area Hospital, Antrim BT41 2RL, UK
| | - Tomas Vymazal
- Department of Anesthesiology and Intensive Medicine, University Hospital Motol, V Úvalu 84, 15000 Praha, Czech Republic;
- Correspondence: ; Tel.: +420-606-413-489
| |
Collapse
|
8
|
Eber E, Goussard P. Bronchoscopy precautions and recommendations in the COVID-19 pandemic. Paediatr Respir Rev 2021; 37:68-73. [PMID: 33583721 PMCID: PMC7843245 DOI: 10.1016/j.prrv.2021.01.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 01/08/2021] [Indexed: 12/23/2022]
Abstract
As the airways of SARS-CoV-2 infected patients contain a high viral load, bronchoscopy is associated with increased risk of patient to health care worker transmission due to aerosolised viral particles and contamination of surfaces during bronchoscopy. Bronchoscopy is not appropriate for diagnosing SARS-CoV-2 infection and, as an aerosol generating procedure involving a significant risk of transmission, has a very limited role in the management of SARS-CoV-2 infected patients including children. During the SARS-CoV-2 pandemic rigid bronchoscopy should be avoided due to the increased risk of droplet spread. Flexible bronchoscopy should be performed first in SARS-CoV-2 positive individuals or in unknown cases, to determine if rigid bronchoscopy is indicated. When available single-use flexible bronchoscopes may be considered for use; devices are available with a range of diameters, and improved image quality and degrees of angulation. When rigid bronchoscopy is necessary, jet ventilation must be avoided and conventional ventilation be used to reduce the risk of aerosolisation. Adequate personal protection equipment is key, as is training of health care workers in correct donning and doffing. Modified full face masks are a practical and safe alternative to filtering facepieces for use in bronchoscopy. When anaesthetic and infection prevention control protocols are strictly adhered to, bronchoscopy can be performed in SARS-CoV-2 positive children.
Collapse
Affiliation(s)
- Ernst Eber
- Division of Paediatric Pulmonology and Allergology, Department of Paediatrics and Adolescent Medicine, Medical University of Graz, Auenbruggerplatz 34/2, A-8036 Graz, Austria
| | - Pierre Goussard
- Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg Hospital, Cape Town, South Africa.
| |
Collapse
|
9
|
Goussard P, Pohunek P, Eber E, Midulla F, Di Mattia G, Merven M, Janson JT. Pediatric bronchoscopy: recent advances and clinical challenges. Expert Rev Respir Med 2021; 15:453-475. [PMID: 33512252 DOI: 10.1080/17476348.2021.1882854] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Introduction: During the last 40 years equipment has been improved with smaller instruments and sufficient size working channels. This has ensured that bronchoscopy offers therapeutic and interventional options.Areas covered: We provide a review of recent advances and clinical challenges in pediatric bronchoscopy. This includes single-use bronchoscopes, endobronchial ultrasound, and cryoprobe. Bronchoscopy in persistent preschool wheezing and asthma is included. The indications for interventional bronchoscopy have amplified and included balloon dilatation, endoscopic intubation, the use of airway stents, whole lung lavage, closing of fistulas and air leak, as well as an update on removal of foreign bodies. Others include the use of laser and microdebrider in airway surgery. Experience with bronchoscope during the COVID-19 pandemic has been included in this review. PubMed was searched for articles on pediatric bronchoscopy, including rigid bronchoscopy as well as interventional bronchoscopy with a focus on reviewing literature in the past 5 years.Expert opinion: As the proficiency of pediatric interventional pulmonologists continues to grow more interventions are being performed. There is a scarcity of published evidence in this field. Courses for pediatric interventional bronchoscopy need to be developed. The COVID-19 experience resulted in safer bronchoscopy practice for all involved.
Collapse
Affiliation(s)
- P Goussard
- Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg Hospital, Cape Town, South Africa
| | - P Pohunek
- Division of Pediatric Respiratory Diseases, Pediatric Department, 2nd Faculty of Medicine, Charles University and University Hospital Motol, Prague, Czech Republic
| | - E Eber
- Department of Paediatrics and Adolescent Medicine, Head, Division of Paediatric Pulmonology and Allergology, Medical University of Graz, Graz, Austria
| | - F Midulla
- Department of Maternal Infantile and Urological Sciences, "Sapienza" University of Rome, Rome, Italy
| | - G Di Mattia
- Department of Maternal Infantile and Urological Sciences, "Sapienza" University of Rome, Rome, Italy
| | - M Merven
- Department Otorhinolaryngology, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg Hospital, Cape Town, South Africa
| | - J T Janson
- Department of Surgical Sciences, Division of Cardio-Thoracic Surgery, Stellenbosch University, and Tygerberg Hospital, Tygerberg, South Africa
| |
Collapse
|
10
|
Barron SP, Kennedy MP. Single-Use (Disposable) Flexible Bronchoscopes: The Future of Bronchoscopy? Adv Ther 2020; 37:4538-4548. [PMID: 32944885 PMCID: PMC7497855 DOI: 10.1007/s12325-020-01495-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 09/03/2020] [Indexed: 12/11/2022]
Abstract
The coronavirus disease (COVID-19) pandemic has highlighted the importance of reducing occupational exposure to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The reprocessing procedure for reusable flexible bronchoscopes (RFBs) involves multiple episodes of handling of equipment that has been used during an aerosol-generating procedure and thus is a potential source of transmission. Single-use flexible bronchoscopes (SUFBs) eliminate this source. Additionally, RFBs pose a risk of nosocomial infection transmission between patients with the identification of human proteins, deoxyribonucleic acid (DNA) and pathogenic organisms on fully reprocessed bronchoscopes despite full adherence to the guidelines. Bronchoscopy units have been hugely impacted by the pandemic with restructuring of pre- and post-operative areas, altered patient protocols and the reassessment of air exchange and cleaning procedures. SUFBs can be incorporated into these protocols as a means of improving occupational safety. Most studies on the efficacy of SUFBs have occurred in an anaesthetic setting so it remains to be seen whether they will perform to an acceptable standard in complex respiratory procedures such as transbronchial biopsies and cryotherapy. Here, we outline their potential uses in a respiratory setting, both during and after the current pandemic.
Collapse
|
11
|
Kriege M, Dalberg J, McGrath BA, Shimabukuro-Vornhagen A, Billgren B, Lund TK, Thornberg K, Christophersen AV, Dunn MJ. Evaluation of intubation and intensive care use of the new Ambu® aScope™ 4 broncho and Ambu® aView™ compared to a customary flexible endoscope a multicentre prospective, non-interventional study. TRENDS IN ANAESTHESIA AND CRITICAL CARE 2020. [DOI: 10.1016/j.tacc.2020.02.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
12
|
Ahmad I, El-Boghdadly K, Bhagrath R, Hodzovic I, McNarry AF, Mir F, O'Sullivan EP, Patel A, Stacey M, Vaughan D. Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults. Anaesthesia 2019; 75:509-528. [PMID: 31729018 PMCID: PMC7078877 DOI: 10.1111/anae.14904] [Citation(s) in RCA: 219] [Impact Index Per Article: 43.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/06/2019] [Indexed: 12/13/2022]
Abstract
Awake tracheal intubation has a high success rate and a favourable safety profile but is underused in cases of anticipated difficult airway management. These guidelines are a comprehensive document to support decision making, preparation and practical performance of awake tracheal intubation. We performed a systematic review of the literature seeking all of the available evidence for each element of awake tracheal intubation in order to make recommendations. In the absence of high‐quality evidence, expert consensus and a Delphi study were used to formulate recommendations. We highlight key areas of awake tracheal intubation in which specific recommendations were made, which included: indications; procedural setup; checklists; oxygenation; airway topicalisation; sedation; verification of tracheal tube position; complications; management of unsuccessful awake tracheal intubation; post‐tracheal intubation management; consent; and training. We recognise that there are a range of techniques and regimens that may be effective and one such example technique is included. Breaking down the key practical elements of awake tracheal intubation into sedation, topicalisation, oxygenation and performance might help practitioners to plan, perform and address complications. These guidelines aim to support clinical practice and help lower the threshold for performing awake tracheal intubation when indicated.
Collapse
Affiliation(s)
- I Ahmad
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK.,King's College London, London, UK
| | - K El-Boghdadly
- Department of Anaesthesia, Guy's and St Thomas' NHS Foundation Trust, London, UK.,King's College London, London, UK
| | - R Bhagrath
- Department of Anaesthesia, Barts Health NHS Trust, London, UK
| | - I Hodzovic
- Department of Anaesthesia, Cardiff University School of Medicine, Cardiff, UK.,Department of Anaesthesia, Aneurin Bevan University Health Board, Newport, UK
| | - A F McNarry
- Department of Anaesthesia, NHS Lothian, Edinburgh, UK
| | - F Mir
- Department of Anaesthesia, St. George's University Hospital NHS Foundation Trust, London, UK
| | - E P O'Sullivan
- Department of Anaesthesia, St James's Hospital, Dublin, Ireland
| | - A Patel
- Department of Anaesthesia, Royal National Throat Nose and Ear Hospital and University College London Hospitals NHS Foundation Trust, London, UK
| | - M Stacey
- Department of Anaesthesia, Cardiff and Vale NHS Trust (HEIW), Cardiff, UK
| | - D Vaughan
- Department of Anaesthesia, Northwick Park Hospital, London, UK
| |
Collapse
|
13
|
Experience With the Use of Single-Use Disposable Bronchoscope in the ICU in a Tertiary Referral Center of Singapore. J Bronchology Interv Pulmonol 2017; 24:136-143. [PMID: 28323727 DOI: 10.1097/lbr.0000000000000335] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Flexible bronchoscopy is performed frequently in intensive care units (ICUs) for various indications using the reusable conventional bronchoscope (CB). Recently, "single-use disposable bronchoscope" (SB) was introduced into the health care industry. The purpose of this study was to compare the utility of SB with CB in ICU. METHODS A retrospective review of medical records of patients undergoing flexible bronchoscopy in the ICUs in the year 2015. RESULTS Ninety-three patients undergoing flexible bronchoscopy in the ICU were studied. Eighty-three bronchoscopies were performed using SB in 71 patients, and 24 using CB in 22 patients. The most common indications for using the SB were percutaneous tracheostomy [n=37 (44.6%)] in neuro-ICU, followed by collecting specimens for microbiological evaluation [n=20 (24.1%)] in the medical ICU. Airway inspection [8 (9.6%)], bronchial toilet [8 (9.6%)], hemoptysis [5 (6%)], and intubation [3 (3.6%)] were other indications for which SB was used. Microbiological yield of SB was 70% (14/20) versus 70% (7/10) for CB (P=1.0). The median interval between identification of the need-to-start of the procedure was shorter with SB (10 min) versus CB (66 min, P=0.01), whereas the cost was similar, SGD450 versus SGD472, respectively. In addition, less (3 personnel) were needed to perform bronchoscopy with SB versus 5 with CB with additional resource sparing effect in terms of nursing personnel having to wheel the CB equipment to ICU. CONCLUSIONS SB is equivalent in performance to CB in ICU. In addition, the SB may confer clinical, economic, and logistical advantages over the CB.
Collapse
|
14
|
Reena. Use of Ambu® aScope™ 3 in difficult airway management in giant lipoma neck. EGYPTIAN JOURNAL OF ANAESTHESIA 2017. [DOI: 10.1016/j.egja.2016.10.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Affiliation(s)
- Reena
- Heritage Institute of Medical Sciences, Varanasi, Uttar Pradesh, India
| |
Collapse
|
15
|
Artime CA, Altamirano A, Normand KC, Ferrario L, Aijazi H, Cattano D, Hagberg CA. Flexible optical intubation via the Ambu Aura-i vs blind intubation via the single-use LMA Fastrach: a prospective randomized clinical trial. J Clin Anesth 2016; 33:41-6. [DOI: 10.1016/j.jclinane.2016.01.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 01/05/2016] [Accepted: 01/11/2016] [Indexed: 10/22/2022]
|
16
|
Aawsaj Y, Light D, Brown J, Horgan L. Use of the Ambu ® aScope 2 TM in laparoscopic common bile duct exploration. Surg Endosc 2016; 30:5153-5155. [PMID: 26983437 DOI: 10.1007/s00464-016-4839-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Accepted: 02/18/2016] [Indexed: 12/31/2022]
Abstract
BACKGROUND We have recently begun to use a sterile disposable endoscope to perform laparoscopic common bile duct exploration. We evaluated our practice in a large district general hospital and reported the early feasibility of this equipment in performing bile duct exploration. METHODS We began to use the Ambu® aScope 2TM from June 2015 in our institution. Any case eligible for a laparoscopic common bile duct exploration was included. Our study period is from June 2015 to November 2015. Data were collected and analysed retrospectively. RESULTS Thirteen patients were included. Nine were female and five were male. The mean age was 59 years old (range 28 to 82 years). Seven were performed as an emergency and six were performed for elective cases. All patients had common bile duct stones with no history of previous cholecystectomy. The Ambu® aScope 2TM was used in 11 cases, and a standard choledocoscope was used in two cases due to lack of availability of the Ambu® aScope 2TM. There was one conversion due to an impacted bile duct stone and technical difficulty intra-operatively. Five cases were performed as a transcystic exploration with 1 case being converted to a choledocotomy due to inability to pass the cystic duct using the Ambu® aScope 2TM. The mean operating time was 158 min (range 85-255 min). The mean operative time using the reusable endoscope was 130 min. The mean postoperative stay was 3 days (range 0-8 days). CONCLUSIONS The use of the Ambu® aScope 2TM is safe and feasible in laparoscopic common bile duct exploration. It confers significant financial benefits and offers an economical alternative to expensive reusable endoscopes.
Collapse
Affiliation(s)
- Yousif Aawsaj
- Northumbria NHS Trust, Rake Lane, North Shields, NE29 8NH, UK
| | - Duncan Light
- Northumbria NHS Trust, Rake Lane, North Shields, NE29 8NH, UK.
| | - Jamie Brown
- Northumbria NHS Trust, Rake Lane, North Shields, NE29 8NH, UK
| | - Liam Horgan
- Northumbria NHS Trust, Rake Lane, North Shields, NE29 8NH, UK
| |
Collapse
|
17
|
Abstract
Recent technological advances have made airway management safer. Because difficult intubation remains challenging to predict, having tools readily available that can be used to manage a difficult airway in any setting is critical. Fortunately, video technology has resulted in improvements for intubation performance while using laryngoscopy by various means. These technologies have been applied to rigid optical stylets, flexible intubation scopes, and, most notably, rigid laryngoscopes. These tools have proven effective for the anticipated difficult airway as well as the unanticipated difficult airway.
Collapse
Affiliation(s)
- Michael Aziz
- Department of Anesthesiology & Perioperative Medicine, Oregon Health & Science University, Porltand, Oregon, 97239, USA
| |
Collapse
|
18
|
Khalifa OSM. Evaluation of Ambu® aScope™ 2 in awake nasotracheal intubation in anticipated difficult airway using conventional or facilitated technique: A randomized controlled trial. EGYPTIAN JOURNAL OF ANAESTHESIA 2015. [DOI: 10.1016/j.egja.2015.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
19
|
Randomised Controlled trial Comparing the Ambu® aScope™2 with a Conventional Fibreoptic Bronchoscope in Orotracheal Intubation of Anaesthetised Adult Patients. Anaesth Intensive Care 2015; 43:479-84. [DOI: 10.1177/0310057x1504300410] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Fibreoptic intubation remains an essential skill for anaesthetists to master. In addition to the reusable fibrescope, an alternative disposable videoscope is available (aScope™2, Ambu®, Ballerup, Denmark). A total of 60 anaesthetised adult patients were randomised to either having orotracheal intubation using the aScope 2 or a Karl Storz fibrescope. Intubations were performed by experienced operators who were familiar with both devices. The primary outcome was the Global Rating Scale score. Secondary outcomes included intubation success, number of intubation attempts and intubation time. Other subjective outcomes including practicality, useability and image quality were also recorded. There was no significant difference in the Global Rating Scale score, intubation success or intubation time between the aScope 2 or Karl Storz fibrescope. Global Rating Scale scores were three and two in the aScope 2 and Karl Storz groups respectively ( P=0.14). All of the other subjective outcomes were similar between the two groups, except that operators found it easier to use the aScope 2 compared to the fibrescope. There was no significant difference in clinical performance between the aScope 2 and the Karl Storz fibreoptic bronchoscope. The aScope's practicality, disposability and recently improved version (aScope™3) potentially make it an acceptable alternative to the reusable fibrescope.
Collapse
|
20
|
McCahon RA, Whynes DK. Cost comparison of re-usable and single-use fibrescopes in a large English teaching hospital. Anaesthesia 2015; 70:699-706. [DOI: 10.1111/anae.13011] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/14/2014] [Indexed: 01/01/2023]
Affiliation(s)
- R. A. McCahon
- Department of Anaesthesia; Queen's Medical Centre; Nottingham University Hospitals NHS Trust; Nottingham UK
| | - D. K. Whynes
- School of Economics; University of Nottingham; Nottingham UK
| |
Collapse
|