1
|
Wang C, Xia Y, Duan W, Yu Y, Yang Q, Jie J, Zhang X, Jie J. In situ fabrication of self-filtered near-infrared Ti 3C 2T x/n-Si Schottky-barrier photodiodes for a continuous non-invasive photoplethysmographic system. NANOSCALE 2025; 17:1021-1030. [PMID: 39589233 DOI: 10.1039/d4nr03110e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2024]
Abstract
Two-dimensional (2D) MXenes have emerged as promising candidates to serve as Schottky contact electrodes for the development of high-performance photodiodes owing to their extraordinary electronic properties. However, it remains a formidable challenge to fabricate a large-area, uniform MXene layer for practical device application. Here, we develop a facile route to produce a large-area Ti3C2Tx layer by post-etching treatment of a pulsed laser-deposited Ti3AlC2 film, enabling the in situ construction of a back-illuminated Ti3C2Tx/n-Si Schottky-barrier photodiode. Significantly, the device exhibits excellent performance with a distinctive self-filtered near-infrared (NIR) photoresponse behavior in the range of 700-1100 nm. By avoiding disturbances caused by ambient light, the NIR photodiode-based transmission-type photoplethysmographic (PPG) measurement system is capable of more reliable detection of PPG waveforms than the commercial PPG sensors for continuously monitoring heart rate. This enables the accurate extraction of blood pressures using a PPG-only method. Our findings not only pave the way for fabrication of a high-quality large-area 2D MXene layer, but also provide a general design principle for developing high-performance MXene/Si photodiodes for health monitoring systems.
Collapse
Affiliation(s)
- Chen Wang
- School of Microelectronics, Micro Electromechanical System Research Center of Engineering and Technology of Anhui Province, Hefei University of Technology, Hefei, Anhui 230009, P. R. China.
| | - Yu Xia
- School of Microelectronics, Micro Electromechanical System Research Center of Engineering and Technology of Anhui Province, Hefei University of Technology, Hefei, Anhui 230009, P. R. China.
| | - Wenli Duan
- School of Microelectronics, Micro Electromechanical System Research Center of Engineering and Technology of Anhui Province, Hefei University of Technology, Hefei, Anhui 230009, P. R. China.
| | - Yongqiang Yu
- School of Microelectronics, Micro Electromechanical System Research Center of Engineering and Technology of Anhui Province, Hefei University of Technology, Hefei, Anhui 230009, P. R. China.
| | - Qingyan Yang
- Department of General Practice, The First Affiliated Hospital of USTC, Hefei 230001, P. R. China.
| | - Jianyong Jie
- Chinese Medicine Hospital of Nanfeng County, Nanfeng, Jiangxi 344500, P. R. China
| | - Xiujuan Zhang
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou, Jiangsu 215123, P. R. China.
| | - Jiansheng Jie
- Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou, Jiangsu 215123, P. R. China.
| |
Collapse
|
2
|
Böttcher S, Zabler N, Jackson M, Bruno E, Biondi A, Epitashvili N, Vieluf S, Dümpelmann M, Richardson MP, Brinkmann BH, Loddenkemper T, Schulze-Bonhage A. Effects of epileptic seizures on the quality of biosignals recorded from wearables. Epilepsia 2024; 65:3513-3525. [PMID: 39373185 DOI: 10.1111/epi.18138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 09/19/2024] [Accepted: 09/20/2024] [Indexed: 10/08/2024]
Abstract
OBJECTIVE Wearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri-ictal periods in performing a feature-based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring. METHODS This study assesses the signal quality of wearable data during peri-ictal phases of generalized tonic-clonic and focal to bilateral tonic-clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri-ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS. RESULTS We analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre- and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity. SIGNIFICANCE Motor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist-worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.
Collapse
Affiliation(s)
- Sebastian Böttcher
- Epilepsy Center, University Medical Center-University of Freiburg, Freiburg, Germany
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
| | - Nicolas Zabler
- Epilepsy Center, University Medical Center-University of Freiburg, Freiburg, Germany
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
| | - Michele Jackson
- Division of Epilepsy and Clinical Neurophysiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Elisa Bruno
- Department of Basic and Clinical Neuroscience, Institute of Psychiatry, Psychology, and Neuroscience, King's College London, London, UK
| | - Andrea Biondi
- Department of Basic and Clinical Neuroscience, Institute of Psychiatry, Psychology, and Neuroscience, King's College London, London, UK
| | - Nino Epitashvili
- Epilepsy Center, University Medical Center-University of Freiburg, Freiburg, Germany
| | - Solveig Vieluf
- Division of Epilepsy and Clinical Neurophysiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
- Department of Medicine I, LMU University Hospital, LMU Munich, Munich, Germany
- German Center for Cardiovascular Research, Partner Site Munich Heart Alliance, Munich, Germany
| | - Matthias Dümpelmann
- Epilepsy Center, University Medical Center-University of Freiburg, Freiburg, Germany
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
| | - Mark P Richardson
- Department of Basic and Clinical Neuroscience, Institute of Psychiatry, Psychology, and Neuroscience, King's College London, London, UK
| | - Benjamin H Brinkmann
- Department of Neurology and Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, USA
| | - Tobias Loddenkemper
- Division of Epilepsy and Clinical Neurophysiology, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | | |
Collapse
|
3
|
Wireless monitoring devices in hospitalized children: a scoping review. Eur J Pediatr 2023; 182:1991-2003. [PMID: 36859727 PMCID: PMC9977642 DOI: 10.1007/s00431-023-04881-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 02/06/2023] [Accepted: 02/14/2023] [Indexed: 03/03/2023]
Abstract
The purpose of this study is to provide a structured overview of existing wireless monitoring technologies for hospitalized children. A systematic search of the literature published after 2010 was conducted in Medline, Embase, Scielo, Cochrane, and Web of Science. Two investigators independently reviewed articles to determine eligibility for inclusion. Information on study type, hospital setting, number of participants, use of a reference sensor, type and number of vital signs monitored, duration of monitoring, type of wireless information transfer, and outcomes of the wireless devices was extracted. A descriptive analysis was applied. Of the 1130 studies identified from our search, 42 met eligibility for subsequent analysis. Most included studies were observational studies with sample sizes of 50 or less published between 2019 and 2022. Common problems pertaining to study methodology and outcomes observed were short duration of monitoring, single focus on validity, and lack information on wireless transfer and data management. Conclusion: Research on the use of wireless monitoring for children in hospitals has been increasing in recent years but often limited by methodological problems. More rigorous studies are necessary to establish the safety and accuracy of novel wireless monitoring devices in hospitalized children. What is Known: • Continuous monitoring of vital signs using wired sensors is the standard of care for hospitalized pediatric patients. However, the use of wires may pose significant challenges to optimal care. What is New: • Interest in wireless monitoring for hospitalized pediatric patients has been rapidly growing in recent years. • However, most devices are in early stages of clinical testing and are limited by inconsistent clinical and technological reporting.
Collapse
|
4
|
Böttcher S, Bruno E, Manyakov NV, Epitashvili N, Claes K, Glasstetter M, Thorpe S, Lees S, Dümpelmann M, Van Laerhoven K, Richardson MP, Schulze-Bonhage A. Detecting Tonic-Clonic Seizures in Multimodal Biosignal Data From Wearables: Methodology Design and Validation. JMIR Mhealth Uhealth 2021; 9:e27674. [PMID: 34806993 PMCID: PMC8663471 DOI: 10.2196/27674] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 07/23/2021] [Accepted: 09/03/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Video electroencephalography recordings, routinely used in epilepsy monitoring units, are the gold standard for monitoring epileptic seizures. However, monitoring is also needed in the day-to-day lives of people with epilepsy, where video electroencephalography is not feasible. Wearables could fill this gap by providing patients with an accurate log of their seizures. OBJECTIVE Although there are already systems available that provide promising results for the detection of tonic-clonic seizures (TCSs), research in this area is often limited to detection from 1 biosignal modality or only during the night when the patient is in bed. The aim of this study is to provide evidence that supervised machine learning can detect TCSs from multimodal data in a new data set during daytime and nighttime. METHODS An extensive data set of biosignals from a multimodal watch worn by people with epilepsy was recorded during their stay in the epilepsy monitoring unit at 2 European clinical sites. From a larger data set of 243 enrolled participants, those who had data recorded during TCSs were selected, amounting to 10 participants with 21 TCSs. Accelerometry and electrodermal activity recorded by the wearable device were used for analysis, and seizure manifestation was annotated in detail by clinical experts. Ten accelerometry and 3 electrodermal activity features were calculated for sliding windows of variable size across the data. A gradient tree boosting algorithm was used for seizure detection, and the optimal parameter combination was determined in a leave-one-participant-out cross-validation on a training set of 10 seizures from 8 participants. The model was then evaluated on an out-of-sample test set of 11 seizures from the remaining 2 participants. To assess specificity, we additionally analyzed data from up to 29 participants without TCSs during the model evaluation. RESULTS In the leave-one-participant-out cross-validation, the model optimized for sensitivity could detect all 10 seizures with a false alarm rate of 0.46 per day in 17.3 days of data. In a test set of 11 out-of-sample TCSs, amounting to 8.3 days of data, the model could detect 10 seizures and produced no false positives. Increasing the test set to include data from 28 more participants without additional TCSs resulted in a false alarm rate of 0.19 per day in 78 days of wearable data. CONCLUSIONS We show that a gradient tree boosting machine can robustly detect TCSs from multimodal wearable data in an original data set and that even with very limited training data, supervised machine learning can achieve a high sensitivity and low false-positive rate. This methodology may offer a promising way to approach wearable-based nonconvulsive seizure detection.
Collapse
Affiliation(s)
- Sebastian Böttcher
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany.,Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Elisa Bruno
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom
| | - Nikolay V Manyakov
- Data Science Analytics & Insights, Janssen Research & Development, Beerse, Belgium
| | - Nino Epitashvili
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | | | - Martin Glasstetter
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | - Sarah Thorpe
- The RADAR-CNS Patient Advisory Board, King's College London, London, United Kingdom
| | - Simon Lees
- The RADAR-CNS Patient Advisory Board, King's College London, London, United Kingdom
| | - Matthias Dümpelmann
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | - Kristof Van Laerhoven
- Ubiquitous Computing, Department of Electrical Engineering and Computer Science, University of Siegen, Siegen, Germany
| | - Mark P Richardson
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, United Kingdom.,National Institute of Health Research Biomedical Research Centre, South London and Maudsley NHS Foundation Trust, London, United Kingdom
| | - Andreas Schulze-Bonhage
- Epilepsy Center, Department of Neurosurgery, Medical Center - University of Freiburg, Freiburg im Breisgau, Germany
| | -
- see Acknowledgements, London, United Kingdom
| |
Collapse
|
5
|
Glasstetter M, Böttcher S, Zabler N, Epitashvili N, Dümpelmann M, Richardson MP, Schulze-Bonhage A. Identification of Ictal Tachycardia in Focal Motor- and Non-Motor Seizures by Means of a Wearable PPG Sensor. SENSORS (BASEL, SWITZERLAND) 2021; 21:6017. [PMID: 34577222 PMCID: PMC8470979 DOI: 10.3390/s21186017] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 08/31/2021] [Accepted: 09/01/2021] [Indexed: 11/16/2022]
Abstract
Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.
Collapse
Affiliation(s)
- Martin Glasstetter
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Sebastian Böttcher
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Nicolas Zabler
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Nino Epitashvili
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Matthias Dümpelmann
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| | - Mark P. Richardson
- Division of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience King’s College London, London SE5 9RT, UK;
| | - Andreas Schulze-Bonhage
- Epilepsy Center, Department of Neurosurgery, Medical Center—University of Freiburg, 79106 Freiburg im Breisgau, Germany; (S.B.); (N.Z.); (N.E.); (M.D.); (A.S.-B.)
| |
Collapse
|
6
|
Tang J, El Atrache R, Yu S, Asif U, Jackson M, Roy S, Mirmomeni M, Cantley S, Sheehan T, Schubach S, Ufongene C, Vieluf S, Meisel C, Harrer S, Loddenkemper T. Seizure detection using wearable sensors and machine learning: Setting a benchmark. Epilepsia 2021; 62:1807-1819. [PMID: 34268728 PMCID: PMC8457135 DOI: 10.1111/epi.16967] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 06/02/2021] [Accepted: 06/02/2021] [Indexed: 12/18/2022]
Abstract
OBJECTIVE Tracking seizures is crucial for epilepsy monitoring and treatment evaluation. Current epilepsy care relies on caretaker seizure diaries, but clinical seizure monitoring may miss seizures. Wearable devices may be better tolerated and more suitable for long-term ambulatory monitoring. This study evaluates the seizure detection performance of custom-developed machine learning (ML) algorithms across a broad spectrum of epileptic seizures utilizing wrist- and ankle-worn multisignal biosensors. METHODS We enrolled patients admitted to the epilepsy monitoring unit and asked them to wear a wearable sensor on either their wrists or ankles. The sensor recorded body temperature, electrodermal activity, accelerometry (ACC), and photoplethysmography, which provides blood volume pulse (BVP). We used electroencephalographic seizure onset and offset as determined by a board-certified epileptologist as a standard comparison. We trained and validated ML for two different algorithms: Algorithm 1, ML methods for developing seizure type-specific detection models for nine individual seizure types; and Algorithm 2, ML methods for building general seizure type-agnostic detection, lumping together all seizure types. RESULTS We included 94 patients (57.4% female, median age = 9.9 years) and 548 epileptic seizures (11 066 h of sensor data) for a total of 930 seizures and nine seizure types. Algorithm 1 detected eight of nine seizure types better than chance (area under the receiver operating characteristic curve [AUC-ROC] = .648-.976). Algorithm 2 detected all nine seizure types better than chance (AUC-ROC = .642-.995); a fusion of ACC and BVP modalities achieved the best AUC-ROC (.752) when combining all seizure types together. SIGNIFICANCE Automatic seizure detection using ML from multimodal wearable sensor data is feasible across a broad spectrum of epileptic seizures. Preliminary results show better than chance seizure detection. The next steps include validation of our results in larger datasets, evaluation of the detection utility tool for additional clinical seizure types, and integration of additional clinical information.
Collapse
Affiliation(s)
- Jianbin Tang
- IBM Research Australia, Melbourne, Victoria, Australia
| | - Rima El Atrache
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Shuang Yu
- IBM Research Australia, Melbourne, Victoria, Australia
| | - Umar Asif
- IBM Research Australia, Melbourne, Victoria, Australia
| | - Michele Jackson
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Subhrajit Roy
- IBM Research Australia, Melbourne, Victoria, Australia.,Google Brain, London, UK
| | | | - Sarah Cantley
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Theodore Sheehan
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Sarah Schubach
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Claire Ufongene
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Solveig Vieluf
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| | - Christian Meisel
- Department of Neurology, Charité-Universitätsmedizin Berlin, Berlin, Germany.,Berlin Institute of Health, Berlin, Germany
| | - Stefan Harrer
- IBM Research Australia, Melbourne, Victoria, Australia.,Digital Health Cooperative Research Centre, Melbourne, Victoria, Australia
| | - Tobias Loddenkemper
- Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|