1
|
Tsai CK, Cheng HH, Hsu TY, Wang JY, Hung CH, Tsai CC, Lai YJ, Lin YJ, Huang HC, Chan JYH, Tain YL, Chen CC, Tsai TA, Yu HR. Prenatal Exposure to Di-Ethyl Phthalate (DEP) Is Related to Increasing Neonatal IgE Levels and the Altering of the Immune Polarization of Helper-T Cells. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18126364. [PMID: 34208324 PMCID: PMC8296186 DOI: 10.3390/ijerph18126364] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/07/2021] [Accepted: 06/08/2021] [Indexed: 11/20/2022]
Abstract
Introduction: Phthalates are substances that are added to plastic products to increase their plasticity. These substances are released easily into the environment and can act as endocrine disruptors. Epidemiological studies in children have showed inconsistent findings regarding the relationship between prenatal or postnatal exposure to phthalates and the risk of allergic disease. Our hypothesis is that prenatal exposure to phthalates may contribute to the development of allergies in children. Material and methods: The objective of this study was to determine the associations between urinary phthalate metabolite concentrations in pregnant women, maternal atopic diathesis, maternal lifestyle, and cord blood IgE. Pregnant mothers and paired newborns (n = 101) were enrolled from an antenatal clinic. The epidemiologic data and the clinical information were collected using standard questionnaires and medical records. The maternal blood and urine samples were collected at 24–28 weeks gestation, and cord blood IgE, IL-12p70, IL-4, and IL-10 levels were determined from the newborns at birth. The link between phthalates and maternal IgE was also assessed. To investigate the effects of phthalates on neonatal immunity, cord blood mononuclear cells (MNCs) were used for cytokine induction in another in vitro experiment. Results: We found that maternal urine monoethyl phthalate (MEP) (a metabolite of di-ethyl phthalate (DEP)) concentrations are positively correlated with the cord blood IgE of the corresponding newborns. The cord blood IL-12p70 levels of mothers with higher maternal urine MEP groups (high DEP exposure) were lower than mothers with low DEP exposure. In vitro experiments demonstrated that DEP could enhance IL-4 production of cord blood MNCs rather than adult MNCs. Conclusion: Prenatal DEP exposure is related to neonatal IgE level and alternation of cytokines relevant to Th1/Th2 polarization. This suggests the existence of a link between prenatal exposure to specific plasticizers and the future development of allergies.
Collapse
Affiliation(s)
- Chang-Ku Tsai
- Department of Pediatrics, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan; (C.-K.T.); (H.-C.H.); (Y.-L.T.); (C.-C.C.); (T.-A.T.)
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan City 33302, Taiwan
| | - Hsin-Hsin Cheng
- Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital-Kaohsiung Medical Centre, Kaohsiung 83301, Taiwan; (H.-H.C.); (T.-Y.H.); (C.-C.T.); (Y.-J.L.); (Y.-J.L.)
| | - Te-Yao Hsu
- Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital-Kaohsiung Medical Centre, Kaohsiung 83301, Taiwan; (H.-H.C.); (T.-Y.H.); (C.-C.T.); (Y.-J.L.); (Y.-J.L.)
| | - Jiu-Yao Wang
- Department of Pediatrics, College of Medicine, National Cheng Kung University, Tainan City 704302, Taiwan;
| | - Chih-Hsing Hung
- Department of Pediatrics, Kaohsiung Medical University Hospital, Kaohsiung 80756, Taiwan;
| | - Ching-Chang Tsai
- Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital-Kaohsiung Medical Centre, Kaohsiung 83301, Taiwan; (H.-H.C.); (T.-Y.H.); (C.-C.T.); (Y.-J.L.); (Y.-J.L.)
| | - Yun-Ju Lai
- Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital-Kaohsiung Medical Centre, Kaohsiung 83301, Taiwan; (H.-H.C.); (T.-Y.H.); (C.-C.T.); (Y.-J.L.); (Y.-J.L.)
| | - Yu-Ju Lin
- Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital-Kaohsiung Medical Centre, Kaohsiung 83301, Taiwan; (H.-H.C.); (T.-Y.H.); (C.-C.T.); (Y.-J.L.); (Y.-J.L.)
| | - Hsin-Chun Huang
- Department of Pediatrics, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan; (C.-K.T.); (H.-C.H.); (Y.-L.T.); (C.-C.C.); (T.-A.T.)
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan City 33302, Taiwan
| | - Julie Y. H. Chan
- Institute for Translational Research in Biomedicine, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan;
| | - You-Lin Tain
- Department of Pediatrics, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan; (C.-K.T.); (H.-C.H.); (Y.-L.T.); (C.-C.C.); (T.-A.T.)
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan City 33302, Taiwan
| | - Chih-Cheng Chen
- Department of Pediatrics, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan; (C.-K.T.); (H.-C.H.); (Y.-L.T.); (C.-C.C.); (T.-A.T.)
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan City 33302, Taiwan
| | - Ti-An Tsai
- Department of Pediatrics, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan; (C.-K.T.); (H.-C.H.); (Y.-L.T.); (C.-C.C.); (T.-A.T.)
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan City 33302, Taiwan
| | - Hong-Ren Yu
- Department of Pediatrics, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 83301, Taiwan; (C.-K.T.); (H.-C.H.); (Y.-L.T.); (C.-C.C.); (T.-A.T.)
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan City 33302, Taiwan
- Correspondence: ; Tel.: +886-7-731-7123 (ext. 8713); Fax: +886-7-733-8009
| |
Collapse
|
2
|
Kociolek LK, Espinosa RO, Gerding DN, Hauser AR, Ozer EA, Budz M, Balaji A, Chen X, Tanz RR, Yalcinkaya N, Conner ME, Savidge T, Kelly CP. Natural Clostridioides difficile Toxin Immunization in Colonized Infants. Clin Infect Dis 2021; 70:2095-2102. [PMID: 31253983 DOI: 10.1093/cid/ciz582] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Accepted: 06/26/2019] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Clostridioides (Clostridium) difficile colonization is common among infants. Serological sequelae of infant C. difficile colonization are poorly understood. METHODS In this prospective cohort study of healthy infants, stools serially collected between ages 1-2 and 9-12 months were tested for non-toxigenic and toxigenic C. difficile (TCD). Cultured isolates underwent whole-genome sequencing. Serum collected at 9-12 months underwent measurement of IgA, IgG, and IgM against TCD toxins A and B and neutralizing antibody (NAb) titers against toxin B. For comparison, antitoxin IgG and NAb were measured in cord blood from 50 mothers unrelated to study infants. RESULTS Among 32 infants, 16 (50%) were colonized with TCD; 12 were first colonized >1 month before serology measurements. A variety of sequence types were identified, and there was evidence of putative in-home (enrolled siblings) and outpatient clinic transmission. Infants first colonized with TCD >1 month prior had significantly greater serum antitoxin IgA and IgG against toxins A (P = .02 for both) and B (P = .009 and .008, respectively) compared with non-TCD-colonized infants, and greater IgG compared with unrelated cord blood (P = .005). Five of 12 (42%) colonized infants had detectable NAb titers compared with zero non-TCD-colonized infants (P = .02). Breastfeeding was not associated with differences in serological measurements. CONCLUSIONS TCD colonization is associated with a humoral immune response against toxins A and B, with evidence of toxin B neutralization in vitro. The extent and duration of protection against CDI later in life afforded by natural C. difficile immunization events require further investigation.
Collapse
Affiliation(s)
- Larry K Kociolek
- Department of Pediatrics, Northwestern University Feinberg School of Medicine.,Division of Infectious Diseases, Ann & Robert H. Lurie Children's Hospital of Chicago
| | - Robyn O Espinosa
- Division of Infectious Diseases, Ann & Robert H. Lurie Children's Hospital of Chicago
| | - Dale N Gerding
- Department of Medicine, Loyola University Chicago Stritch School of Medicine, Hines.,Department of Medicine, Edward Hines Jr Veterans Administration Hospital, Research Service, Hines
| | - Alan R Hauser
- Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago.,Department of Microbiology-Immunology, Northwestern University Feinberg School of Medicine, Chicago
| | - Egon A Ozer
- Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago
| | - Maria Budz
- Special Infectious Diseases Laboratory, Ann & Robert H. Lurie Children's Hospital of Chicago, Illinois
| | - Aakash Balaji
- Department of Pediatrics, Northwestern University Feinberg School of Medicine
| | - Xinhua Chen
- Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Robert R Tanz
- Department of Pediatrics, Northwestern University Feinberg School of Medicine.,Division of Academic General Pediatrics and Primary Care, Ann & Robert H. Lurie Children's Hospital of Chicago, Illinois
| | - Nazli Yalcinkaya
- Department of Pathology and Immunology, Baylor College of Medicine and Texas Children's Hospital, Houston
| | - Margaret E Conner
- Department of Molecular Virology and Microbiology, Baylor College of Medicine, Houston, Texas
| | - Tor Savidge
- Department of Pathology and Immunology, Baylor College of Medicine and Texas Children's Hospital, Houston
| | - Ciaran P Kelly
- Division of Gastroenterology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
3
|
Abstract
Natural antibodies are an innate-like subset of serum antibodies involved in host defense, tumor surveillance, homeostasis, and autoimmunity. Defining the natural antibody repertoire is critical for identifying biomarkers, developing vaccines, controlling and preventing autoimmunity, and understanding the development and organization of the immune system. While natural antibodies to protein antigens have been studied in depth, little is known about natural antibodies to carbohydrate antigens. To address this, we profiled IgM from umbilical cord blood and matched maternal sera on a glycan microarray. Since standard methods to detect maternal contamination in cord serum did not have sufficient sensitivity for our study, we developed a highly sensitive microarray-based assay. Using this method, we found that over 50% of the cord samples had unacceptable levels of maternal contamination. For the cord samples with high purity, anti-glycan IgM antibodies were prevalent and recognized a broad range of non-human and human glycans. Using principal component analysis and hierarchical clustering, cord IgM repertoires showed a high degree of similarity with each other but were distinct from maternal IgM repertoires. Our results demonstrate that many anti-glycan antibodies in human serum are natural antibodies and provide new insights into the development of anti-glycan antibody repertoires.
Collapse
|
4
|
Susanto NH, Schoos AMM, Standl M, Lowe AJ, Dharmage SC, Svanes C, Salim A, von Berg A, Lehmann I, Rasmussen MA, Werchan M, Bergmann KC, Lodge C, Abramson MJ, Heinrich J, Bisgaard H, Erbas B. Environmental grass pollen levels in utero and at birth and cord blood IgE: Analysis of three birth cohorts. ENVIRONMENT INTERNATIONAL 2018; 119:295-301. [PMID: 29990949 DOI: 10.1016/j.envint.2018.06.036] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 06/26/2018] [Accepted: 06/26/2018] [Indexed: 06/08/2023]
Abstract
BACKGROUND Early life factors are associated with allergic respiratory diseases, but the role of high grass pollen concentrations during pregnancy and shortly after birth is not known. OBJECTIVE To assess outdoor levels of grass pollen during the intrauterine period and at birth during peak pollen season on cord blood IgE in birth cohorts. METHODS Three birth cohorts were included: MACS (n = 429), Australia; COPSAC2000 (n = 200), Denmark; and LISA (n = 1968), Germany. Cord blood IgE was categorized (<0.5 kU/L, 0.5-1 kU/L, >1 kU/L) and dichotomized (high IgE ≥ 0.5 kU/L). Birth during the grass pollen season months and cumulative exposure to outdoor grass pollen counts during pregnancy with cord blood IgE were analysed using multinomial regression and analysed in meta-analysis using binomial regression adjusted for potential confounders. RESULTS Birth during the grass pollen season had higher pooled odds of cord blood IgE >0.5 kU/L 1.37 (95% CI 1.06, 1.77) in a meta-analysis with little heterogeneity between the three cohorts. Cumulative exposure to outdoor grass pollen counts during the entire pregnancy was associated with slightly lower pooled odds but significant (OR = 0.98, 95% CI: 0.96 to 0.99). CONCLUSIONS Birth during grass pollen seasons were associated with increased risk of high cord blood IgE in cities from both hemispheres, but high pollen loads in the environment during the entire pregnancy appeared protective. As IgE responses develop during the first months of life, our study findings provide new insights into the mechanisms of grass pollen exposure at birth and shortly after on possible allergic respiratory diseases.
Collapse
Affiliation(s)
- Nugroho Harry Susanto
- School of Pyschology and Public Health, La Trobe University, Melbourne, Australia; Indonesia Research Partnership on Infectious Diseases (INA-RESPOND), Jakarta, Indonesia; Epidemiology and Biostatistics Division, Public Health Department, Faculty of Medicine, Padjadjaran University, Bandung, Indonesia
| | - Ann-Marie Malby Schoos
- Copenhagen Prospective Studies on Asthma in Childhood, Faculty of Health and Medical Sciences, University of Copenhagen & Danish Pediatric Asthma Center, Gentofte Hospital, University of Copenhagen, Denmark
| | - Marie Standl
- Institute of Epidemiology I, Helmholtz Zentrum München - German Research Center for Environmental Health, Neuherberg, Germany
| | - Adrian J Lowe
- Allergy and Lung Health Unit, School of Population and Global Health, The University of Melbourne, Melbourne, Australia
| | - Shyamali C Dharmage
- Allergy and Lung Health Unit, School of Population and Global Health, The University of Melbourne, Melbourne, Australia
| | - Cecilie Svanes
- Centre for International Health, University of Bergen, Norway; Department of Occupational Medicine, Haukeland University Hospital, Norway
| | - Agus Salim
- Department of Mathematics and Statistics, La Trobe University, Melbourne, Australia
| | - Andrea von Berg
- Research Institute, Department of Pediatrics, Marien-Hospital Wesel, Wesel, Germany
| | - Irina Lehmann
- Department of Environmental Immunology/Core Facility Studies, Helmholtz Centre for Environmental Research - UFZ, Leipzig, Germany
| | - Morten Arendt Rasmussen
- Copenhagen Prospective Studies on Asthma in Childhood, Faculty of Health and Medical Sciences, University of Copenhagen & Danish Pediatric Asthma Center, Gentofte Hospital, University of Copenhagen, Denmark
| | | | | | - Caroline Lodge
- Allergy and Lung Health Unit, School of Population and Global Health, The University of Melbourne, Melbourne, Australia
| | - Michael J Abramson
- School of Public Health & Preventive Medicine, Monash University, Melbourne, Australia
| | - Joachim Heinrich
- Institute of Epidemiology I, Helmholtz Zentrum München - German Research Center for Environmental Health, Neuherberg, Germany; Institute and Outpatient Clinic for Occupational, Social and Environmental Medicine, Inner City Clinic, University Hospital of Ludwig Maximilians University, Munich, Comprehensive Pneumology Centre (LMU), Munich, German Centre for Lung Research, Germany
| | - Hans Bisgaard
- Copenhagen Prospective Studies on Asthma in Childhood, Faculty of Health and Medical Sciences, University of Copenhagen & Danish Pediatric Asthma Center, Gentofte Hospital, University of Copenhagen, Denmark
| | - Bircan Erbas
- School of Pyschology and Public Health, La Trobe University, Melbourne, Australia.
| |
Collapse
|
5
|
Kawamoto N, Kamemura N, Kido H, Fukao T. Detection of ovomucoid-specific low-affinity IgE in infants and its relationship to eczema. Pediatr Allergy Immunol 2017; 28:355-361. [PMID: 28140473 DOI: 10.1111/pai.12702] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/26/2017] [Indexed: 01/19/2023]
Abstract
BACKGROUND Allergen-specific low-affinity IgE was previously detected in cord blood by a highly sensitive densely carboxylated protein (DCP) chip, but not by ImmunoCAP. Here, we investigated the presence of low-affinity IgE during the early life of infants and observed its relationship with eczema. METHODS We conducted a birth cohort study, collecting sera at birth and 6 and 14 months of age (n = 110). We monitored the ovomucoid (OM)- and egg white (EW)-specific IgE (sIgE) by ImmunoCAP or DCP chip and analyzed the antigen affinity of sIgE by binding inhibition assays in the presence or absence of a mild chaotropic agent, diethyl amine (DEA). The low- and high-affinity OM-sIgEs and sensitization risk factors were analyzed by a multivariate logistic analysis. RESULTS The OM-sIgE measured by DCP chip significantly correlated with that measured by ImmunoCAP, but some samples assessed as OM-sIgE positive by DCP chip were considered OM-sIgE negative by ImmunoCAP. Binding inhibition analysis after DEA treatment was performed for participants judged as OM-sIgE positive by DCP chip at 14 M. The group assessed as negative for OM- and EW-sIgE by ImmunoCAP at 6 and 14 months showed a larger binding inhibition curve shift after DEA treatment than did the group assessed as positive at these times, indicating the presence of low-affinity sIgE antibodies at 14 months. The logistic regression analysis found that persistent eczema from 6 to 14 months is a significant risk factor for developing high-affinity, but not low-affinity, sIgE. CONCLUSIONS Human infant peripheral blood contains allergen-specific low-affinity sIgE. Persistent eczema is related to the development of high-affinity, but not low-affinity, IgE.
Collapse
Affiliation(s)
- Norio Kawamoto
- Department of Pediatrics, Graduate School of Medicine, Gifu University, Gifu, Japan
| | - Norio Kamemura
- Division of Enzyme Chemistry, Institute for Enzyme Research, Tokushima University, Tokushima, Japan
| | - Hiroshi Kido
- Division of Enzyme Chemistry, Institute for Enzyme Research, Tokushima University, Tokushima, Japan
| | - Toshiyuki Fukao
- Department of Pediatrics, Graduate School of Medicine, Gifu University, Gifu, Japan
| |
Collapse
|
6
|
Ashley-Martin J, Lavigne E, Arbuckle TE, Johnson M, Hystad P, Crouse DL, Marshall JS, Dodds L. Air Pollution During Pregnancy and Cord Blood Immune System Biomarkers. J Occup Environ Med 2016; 58:979-986. [PMID: 27483336 PMCID: PMC5704662 DOI: 10.1097/jom.0000000000000841] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES We aimed to determine whether average and trimester-specific exposures to ambient measures of nitrogen dioxide (NO2) and particular matter (PM2.5) were associated with elevated cord blood concentrations of immunoglobulin E (IgE) and two epithelial cell produced cytokines: interleukin-33 (IL-33) and thymic stromal lymphopoietin (TSLP). METHODS This study utilized data and biospecimens from the Maternal-Infant Research on Environmental Chemicals (MIREC) Study. There were 2001 pregnant women recruited between 2008 and 2011 from 10 Canadian cities. Maternal exposure to NO2 and PM2.5 was estimated using land use regression and satellite-derived models. RESULTS We observed statistically significant associations between maternal NO2 exposure and elevated cord blood concentrations of both IL-33 and TSLP among girls but not boys. CONCLUSIONS Maternal NO2 exposure may impact the development of the newborn immune system as measured by cord blood concentrations of two cytokines.
Collapse
Affiliation(s)
- Jillian Ashley-Martin
- Departments of Obstetrics & Gynecology and Pediatrics, Dalhousie University, Halifax, Nova Scotia (Drs Ashley-Martin, Dodds); Air Health Science Division (Drs Lavigne, Johnson), Population Studies Division, Healthy Environments and Consumer Safety Branch, Health Canada, Ottawa, Ontario, Canada (Dr Arbuckle); College of Public Health and Human Sciences, Oregon State University, Corvallis (Dr Hystad); Department of Sociology, University of New Brunswick, Fredericton, New Brunswick (Dr Crouse); and Department of Microbiology and Immunology, Dalhousie University, Halifax, Nova Scotia, Canada (Dr Marshall)
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Ashley-Martin J, Dodds L, Arbuckle TE, Marshall J. Prenatal triclosan exposure and cord blood immune system biomarkers. Int J Hyg Environ Health 2016; 219:454-7. [PMID: 27167448 DOI: 10.1016/j.ijheh.2016.04.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2016] [Revised: 04/22/2016] [Accepted: 04/23/2016] [Indexed: 01/01/2023]
Abstract
Triclosan is widely used as an antimicrobial agent and preservative that has been hypothesized to play a role in asthma and allergic disease. The limited body of literature regarding the allergenicity of triclosan has not evaluated prenatal exposure and subsequent potential effects on the developing immune system. The objective of the present study was to determine the association between prenatal urinary triclosan concentrations and cord blood immune system biomarker concentrations. Umbilical cord blood samples were obtained from the Maternal-Infant Research on Environmental Chemicals (MIREC) Biobank and were tested for three immune system biomarkers: immunoglobulin E (IgE), thymic stromal lymphopoietin (TSLP), and interleukin-33 (IL-33). Triclosan concentrations were measured in urine at 6-13 weeks gestation. No statistically significant associations were observed between prenatal triclosan concentrations and elevated concentrations of any immune system biomarker (n=1219 participants). Longitudinal studies are necessary to determine how the observed findings at birth translate into childhood.
Collapse
Affiliation(s)
- Jillian Ashley-Martin
- Perinatal Epidemiology Research Unit, Departments of Obstetrics & Gynecology and Pediatrics, Dalhousie University, Halifax, NS B3K 6R8, Canada.
| | - Linda Dodds
- Perinatal Epidemiology Research Unit, Departments of Obstetrics & Gynecology and Pediatrics, Dalhousie University, Halifax, NS B3K 6R8, Canada.
| | - Tye E Arbuckle
- Population Studies Division, Healthy Environments and Consumer Safety Branch, Health Canada, Ottawa, ON K1A 0K9, Canada.
| | - Jean Marshall
- Department of Microbiology & Immunology, Dalhousie University, Halifax, NS B3H 4R2, Canada.
| |
Collapse
|
8
|
Bundhoo A, Paveglio S, Rafti E, Dhongade A, Blumberg RS, Matson AP. Evidence that FcRn mediates the transplacental passage of maternal IgE in the form of IgG anti-IgE/IgE immune complexes. Clin Exp Allergy 2016; 45:1085-98. [PMID: 25652137 PMCID: PMC4437844 DOI: 10.1111/cea.12508] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2014] [Revised: 12/13/2014] [Accepted: 01/12/2015] [Indexed: 01/05/2023]
Abstract
BACKGROUND The mechanism(s) responsible for acquisition of maternal antibody isotypes other than IgG are not fully understood. This uncertainty is a major reason underlying the continued controversy regarding whether cord blood (CB) IgE originates in the mother or fetus. OBJECTIVE To investigate the capacity of maternal IgE to be transported across the placenta in the form of IgG anti-IgE/IgE immune complexes (ICs) and to determine the role of the neonatal Fc receptor (FcRn) in mediating this process. METHODS Maternal and CB serum concentrations of IgE, IgG anti-IgE, and IgG anti-IgE/IgE ICs were determined in a cohort of allergic and non-allergic mother/infant dyads. Madin-Darby canine kidney (MDCK) cells stably transfected with human FcRn were used to study the binding and transcytosis of IgE in the form of IgG anti-IgE/IgE ICs. RESULTS Maternal and CB serum concentrations of IgG anti-IgE/IgE ICs were highly correlated, regardless of maternal allergic status. IgG anti-IgE/IgE ICs generated in vitro bound strongly to FcRn-expressing MDCK cells and were transcytosed in an FcRn-dependent manner. Conversely, monomeric IgE did not bind to FcRn and was not transcytosed. IgE was detected in solutions of transcytosed IgG anti-IgE/IgE ICs, even though essentially all the IgE remained in complex form. Similarly, the majority of IgE in CB sera was found to be complexed to IgG. CONCLUSIONS AND CLINICAL RELEVANCE These data indicate that human FcRn facilitates the transepithelial transport of IgE in the form of IgG anti-IgE/IgE ICs. They also strongly suggest that the majority of IgE in CB sera is the result of FcRn-mediated transcytosis of maternal-derived IgG anti-IgE/IgE ICs. These findings challenge the widespread perception that maternal IgE does not cross the placenta. Measuring maternal or CB levels of IgG anti-IgE/IgE ICs may be a more accurate predictor of allergic risk.
Collapse
Affiliation(s)
- A Bundhoo
- Division of Neonatology, Connecticut Children's Medical Center, Hartford, CT, USA.,Department of Pediatrics, University of Connecticut School of Medicine, Farmington, CT, USA
| | - S Paveglio
- Department of Pediatrics, University of Connecticut School of Medicine, Farmington, CT, USA
| | - E Rafti
- Department of Pediatrics, University of Connecticut School of Medicine, Farmington, CT, USA
| | - A Dhongade
- Division of Neonatology, Connecticut Children's Medical Center, Hartford, CT, USA.,Department of Pediatrics, University of Connecticut School of Medicine, Farmington, CT, USA
| | - R S Blumberg
- Division of Gastroenterology, Brigham and Women's Hospital, Boston, MA, USA
| | - A P Matson
- Division of Neonatology, Connecticut Children's Medical Center, Hartford, CT, USA.,Department of Pediatrics, University of Connecticut School of Medicine, Farmington, CT, USA.,Department of Immunology, University of Connecticut School of Medicine, Farmington, CT, USA
| |
Collapse
|
9
|
Ashley-Martin J, Dodds L, Levy AR, Platt RW, Marshall JS, Arbuckle TE. Prenatal exposure to phthalates, bisphenol A and perfluoroalkyl substances and cord blood levels of IgE, TSLP and IL-33. ENVIRONMENTAL RESEARCH 2015; 140:360-368. [PMID: 25913155 DOI: 10.1016/j.envres.2015.04.010] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2015] [Revised: 04/10/2015] [Accepted: 04/14/2015] [Indexed: 06/04/2023]
Abstract
The fetal time period is a critical window of immune system development and resulting heightened susceptibility to the adverse effects of environmental exposures. Epidemiologists and toxicologists have hypothesized that phthalates, bisphenol A (BPA) and perfluoroalkyl substance have immunotoxic properties. Immunotoxic effects of chemicals may manifest in an altered immune system profile at birth. Immunoglobulin E, thymic stromal lymphopoietin (TSLP), and interleukin-33 (IL-33) are integral in the etiology of childhood allergy and detectable at birth. The objective of this study was to determine the association between maternal levels of phthalates, bisphenol A (BPA), and perfluoroalkyl substances and elevated umbilical cord blood levels of IgE, TSLP, and IL-33. This study utilized data collected in the Maternal-Infant Research on Environmental Chemicals (MIREC) Study, a trans-Canada cohort study of 2001 pregnant women. Of these women, 1258 had a singleton, term birth and cord blood sample. A Bayesian hierarchical model was employed to determine associations between log-transformed continuous variables and immune system biomarkers while adjusting for potential confounding from correlated environmental contaminants. Inverse, nonlinear associations were observed between maternal urinary MCPP levels and elevated levels of both IL-33/TSLP and IgE and between maternal urinary BPA levels and elevated levels of IL-33/TSLP. In this primarily urban Canadian population of pregnant women and their newborns, maternal urinary and plasma concentrations of phthalate metabolites, BPA, and perfluoroalkyl substances were not associated with immunotoxic effects that manifest as increased odds of elevated levels of IgE, TSLP or IL-33.
Collapse
Affiliation(s)
- Jillian Ashley-Martin
- Interdisciplinary PhD Program, Dalhousie University, IDPhD c/o Faculty of Graduate Studies, Room, 314 H Hicks Building, 6299 South Street, Halifax, NS, Canada B3H 4H6.
| | - Linda Dodds
- Department of Obstetrics & Gynaecology and Paediatrics, Dalhousie University, Perinatal Epidemiology Research Unit, 7th Floor Women's Site, IWK Health Centre, 5980 University Avenue, PO Box 9700, Halifax, NS, Canada B3H 6R8.
| | - Adrian R Levy
- Department of Community Health & Epidemiology, Dalhousie University, Centre for Clinical Research, 5790 University Avenue, Halifax, NS, Canada B3H 1V7.
| | - Robert W Platt
- Department of Epidemiology and Biostatistics, McGill University, Purvis Hall, 1020 Pine Avenue, West Montreal, QC, Canada H3A 1A2.
| | - Jean S Marshall
- Department of Microbiology & Immunology, Dalhousie University, Sir Charles Tupper Medical Building, Room 7-C 5850 College Street, Halifax, NS, Canada.
| | - Tye E Arbuckle
- Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Dr., AL 0801A, Ottawa, ON, Canada K1A 0K9.
| |
Collapse
|
10
|
Ashley-Martin J, Levy AR, Arbuckle TE, Platt RW, Marshall JS, Dodds L. Maternal exposure to metals and persistent pollutants and cord blood immune system biomarkers. Environ Health 2015; 14:52. [PMID: 26084354 PMCID: PMC4470054 DOI: 10.1186/s12940-015-0046-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2015] [Accepted: 06/08/2015] [Indexed: 05/06/2023]
Abstract
BACKGROUND The fetal time period is a critical window of immune system development and resulting heightened susceptibility to the adverse effects of environmental exposures. Epidemiologists and toxicologists have hypothesized that persistent organic pollutants, pesticides and metals have immunotoxic properties. Immunotoxic effects may manifest as an altered immune system profile at birth. Immunoglobulin E, thymic stromal lymphopoietin (TSLP), and interleukin-33 (IL-33) may be implicated in the etiology of childhood allergy and are detectable at birth. The objective of this study was to examine the potential relationship between maternal concentrations of metals, persistent organic pollutants, and pesticides and elevated umbilical cord blood concentrations of IgE, TSLP, and IL-33 in a Canadian birth cohort. METHODS This study utilized data collected in the Maternal-Infant Research on Environmental Chemicals (MIREC) Study, a trans-Canada cohort study of 2,001 pregnant women. Of these women, 1258 had a singleton, term birth and cord blood sample. Logistic regression was used to determine associations between log-transformed continuous variables and immune system biomarkers. RESULTS Inverse relationships were observed between lead, DDE, PCB-118, and a summary index of organophosphorous metabolites and jointly elevated concentrations of IL-33 and TSLP. None of the environmental contaminants were associated with increased odds of a high cord blood immune system biomarker concentration. CONCLUSIONS In this primarily urban Canadian population of pregnant women and their newborns, maternal blood or urine concentrations of persistent organic pollutants, pesticides, and metals were not associated with immunotoxic effects that manifest as increased odds of elevated concentrations of IgE, TSLP or IL-33.
Collapse
Affiliation(s)
- Jillian Ashley-Martin
- Interdisciplinary PhD Program, Dalhousie University, IDPhD c/o Faculty of Graduate Studies Room 314 Henry Hicks Building 6299 South St Halifax, Halifax, NS, B3H 4H6, Canada.
| | - Adrian R Levy
- Department of Community Health & Epidemiology, Dalhousie University, Centre for Clinical Research, 5790 University Avenue, Halifax, NS, B3H 1 V7, Canada.
| | - Tye E Arbuckle
- Population Studies Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Dr., AL 0801A, Ottawa, ON, K1A 0 K9, Canada.
| | - Robert W Platt
- Department of Epidemiology and Biostatistics, McGill University, Purvis Hall 1020 Pine Ave. West, Montreal, H3A 1A2, QC, Canada.
| | - Jean S Marshall
- Department of Microbiology & Immunology, Dalhousie University Sir Charles Tupper Medical Building, Room 7-C5850 College Street, Halifax, NS, Canada.
| | - Linda Dodds
- Department of Obstetrics & Gynaecology and Paediatrics, Dalhousie University, Perinatal Epidemiology Research Unit, 7th Floor Women's Site, IWK Health Centre, 5980 University Ave, PO Box 9700, Halifax, NS, B3H 6R8, Canada.
| |
Collapse
|
11
|
Yu Z, Chen J, Zhang Q, Yin X, Wang Y, Fu J, Zou L, Kong W. Maternofetal Transfer of Antibodies and the Influence of Maternal Atopic Status on the Neonate. Am J Rhinol Allergy 2015; 29:119-23. [PMID: 25785752 DOI: 10.2500/ajra.2015.29.4139] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Background Epidemiologic evidence has shown that sensitization of allergic diseases develops early in life, even before birth. The gestational environment, including maternal atopic status and transplacentally transferred antibodies to allergens, may be of importance in the sensitization process. Objective To investigate maternofetal transfer of antibodies and the influence of maternal atopic status on the neonatal immune response. Methods Fifty-seven healthy pregnant women who underwent elective cesarean section (ECS) were recruited. Total and specific IgE (Phadiatop) levels in cord blood (CB) and maternal blood (MB) were determined using the ImmunoCAP assay. MB- and CB-specific IgG1 and IgA1 antibodies against ovalbumin and house dust mite were analyzed by enzyme linked immunosorbent assay. The cytokines, interleukin (IL)-13, interferon (IFN)-γ, and IL-10 in the supernatant of cultured CB mononuclear cells were quantified by enzyme linked immunosorbent assay. Two subgroups were defined based on the maternal levels of specific IgE (atopic group, Phadiatop IgE more than or equal to 0.35 kilo international units of allergen-specific antibody (KUA)/L; nonatopic group, Phadiatop IgE less than 0.35 KUA/L). Results Although total IgE was detectable in all MB samples, it could only be detected in 7% (4/57) of the CB samples. Specific IgE was detectable in all MB samples but undetectable in all CB samples. There was no correlation of total IgE between mothers and their neonates. The concentrations of IL-10, IL-13, and allergen-specific IgG1 and IgA1 in the CB samples did not differ significantly between the atopic and nonatopic groups. IFN-γ was undetectable in the CB samples. Conclusions Maternal IgE cannot be transferred to the child in utero. Maternal atopic status has no significant effect on neonatal immune responses.
Collapse
Affiliation(s)
- Zizhong Yu
- Department of Otorhinolaryngology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei province, China
| | - Jianjun Chen
- Department of Otorhinolaryngology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei province, China
| | - Quanming Zhang
- Department of Otorhinolaryngology, Nanshan Affiliated Hospital of Guangdong Medical College, Shenzhen, Guangdong province, China
| | - Xiaoyan Yin
- Department of Otorhinolaryngology, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei province, China
| | - Yanjun Wang
- Department of Otorhinolaryngology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei province, China
| | - Junmei Fu
- Department of Otorhinolaryngology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei province, China
| | - Li Zou
- Department of Obstetrics and Gynecology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei province, China
| | - Weijia Kong
- Department of Otorhinolaryngology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei province, China
| |
Collapse
|
12
|
Ashley-Martin J, Dodds L, Arbuckle TE, Levy AR, Platt RW, Marshall JS. Predictors of interleukin-33 and thymic stromal lymphopoietin levels in cord blood. Pediatr Allergy Immunol 2015; 26:161-7. [PMID: 25620084 PMCID: PMC4471622 DOI: 10.1111/pai.12340] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/20/2015] [Indexed: 12/24/2022]
Abstract
BACKGROUND The fetal immune system is a critical window of development. The epithelial cell-derived cytokines, thymic stromal lymphopoietin (TSLP), and interleukin-33 (IL-33) have received attention for their role in allergic responses but not been studied during this critical window. The objectives were to assess correlations among IL-33, TSLP, and IgE in umbilical cord blood samples and identify prenatal predictors of these biomarkers. METHODS This study utilized data and banked cord blood collected in the Maternal-Infant Research on Environmental Chemicals (MIREC) Study, a trans-Canada cohort study of 2001 pregnant women. Our analytic sample comprised the 1254 women with a singleton, term birth with a cord blood sample. Spearman correlation coefficients (SCC) and logistic regression models were used to examine associations between biomarkers and identify potential predictors of elevated biomarker levels. RESULTS Thymic stromal lymphopoietin and IL-33 were more strongly correlated with each other (SCC = 0.75, p < 0.0001) than with IgE (IL-33 SCC = 0.14, TSLP SCC = 0.21). Maternal allergy, heavy street traffic, and elevated birth weight were significantly associated with jointly elevated TSLP and IL-33 levels, whereas maternal age and female infant sex were inversely associated with elevated IgE. CONCLUSIONS In this population of Canadian women and infants, TSLP and IL-33 were detectable in cord blood, more strongly correlated with each other than with IgE, and associated with maternal characteristics indicative of inflammatory responses. This study motivates investigation into the value of cord blood IL-33 and TSLP levels as childhood allergy predictors and raises interesting questions regarding in utero coordinated regulation of these cytokines.
Collapse
|
13
|
Nissen SP, Kjaer HF, Høst A, Nielsen J, Halken S. Can family history and cord blood IgE predict sensitization and allergic diseases up to adulthood? Pediatr Allergy Immunol 2015; 26:42-8. [PMID: 25420698 DOI: 10.1111/pai.12264] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/08/2014] [Indexed: 11/28/2022]
Abstract
BACKGROUND Long-term studies of the predictive value of family history and cord blood IgE level until adulthood are few, and their conclusions have been contradictory. METHODS Screening of total IgE in 1617 cord blood samples was performed in a Danish birth cohort. All infants with cord blood IgE (CB-IgE) ≥ 0.5 kU/l and a corresponding randomly chosen group with CB-IgE <0.5 kU/l were chosen for follow-up. Questionnaire-based interviews, physical examination, specific IgE testing, and from 10 yr also spirometry, were carried out at 1½, 5, 10, 15, and 26 yr. Predefined diagnostic criteria were used. RESULTS A total of 455 infants were included, 188 with CB-IgE ≥ 0.5 kU/l and 267 with CB-IgE <0.5 kU/l. Follow-up rates were high, 288 (63%) attended the 26-yr follow-up. Family history and elevated CB-IgE were significantly associated to allergic disease until 26 yr. Concerning any allergic symptoms at 1½ yr the positive and negative predictive values (PPV and NPV), the sensitivity and specificity of CB-IgE ≥ 0.5 kU/l, was 29%, 81%, 54%, and 61%, respectively. The corresponding figures at 26 yr were 46%, 62%, 43%, and 65%. Overall, family history as well as CB-IgE ≥ 0.5 kU/l was associated with high NPV and specificity, but low PPV and sensitivity. CONCLUSION Although family history and elevated CB-IgE were significantly associated with primarily atopic disease until 26 yr, none of these were strong predictors for subsequent sensitization and allergic symptoms from childhood until early adulthood. It appears that the predictive capacity of CB-IgE decreases in adolescence and early adulthood.
Collapse
Affiliation(s)
- Susanne P Nissen
- Hans Christian Andersen Children's Hospital, Odense University Hospital, Odense C, Denmark
| | | | | | | | | |
Collapse
|
14
|
Matson AP, Cloutier MM, Dhongade A, Puddington L, Rafti E. Maternal allergy is associated with surface-bound IgE on cord blood basophils. Pediatr Allergy Immunol 2013; 24:614-21. [PMID: 23980848 PMCID: PMC3798094 DOI: 10.1111/pai.12113] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/10/2013] [Indexed: 12/18/2022]
Abstract
BACKGROUND The cell type(s) mediating the maternal influence on allergic disease in children remain unclear. We set out to define the relationship between maternal allergy and frequencies of cord blood (CB) basophils, and plasmacytoid dendritic cells (pDCs); to characterize surface-bound IgE and FcεRI expressions on these cells; and to investigate the association between maternal and CB serum IgE levels with surface-bound IgE and FcεRI expressions. METHODS One hundred and three mother/infant dyads were recruited prenatally, and maternal allergic history was recorded. Maternal blood was collected prior to delivery, and CB was collected after birth. Flow cytometry was used to identify CB basophils and pDCs and to determine surface-bound IgE and FcεRI expressions. RESULTS Frequencies of CB basophils and pDCs were low and not related to maternal history of allergy. Percentages of CB basophils with surface-bound IgE were significantly higher in infants of allergic mothers compared with infants of non-allergic mothers (median, 59.60% vs. 19.70%, p = 0.01). IgE on CB basophils correlated with CB IgE levels (r = 0.72, p < 0.0001), but not with maternal IgE levels (r = 0.26, p = 0.06). IgE on CB pDCs was low and not significantly associated with maternal or CB IgE levels. Similarly, FcεRI expression by CB basophils and pDCs was not significantly associated with maternal or CB IgE levels. CONCLUSIONS Frequencies of CB basophils and pDCs are not influenced by maternal allergy. CB basophils and pDCs have surface-bound IgE and express FcεRI; however, only IgE on CB basophils appears influenced by maternal allergy.
Collapse
Affiliation(s)
- Adam P Matson
- Department of Immunology, University of Connecticut Health Center, Farmington, CT, USA.
| | | | | | | | | |
Collapse
|
15
|
Relationships between total and allergen-specific serum IgE concentrations and lung function in young adults. Ann Allergy Asthma Immunol 2012; 108:429-34. [PMID: 22626596 DOI: 10.1016/j.anai.2012.04.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2012] [Revised: 04/10/2012] [Accepted: 04/10/2012] [Indexed: 11/21/2022]
Abstract
BACKGROUND Prior studies have shown relationships between serum immunoglobulin E (IgE) and asthma. OBJECTIVE To investigate relationships between total and allergen-specific IgE concentrations and lung function in young adults. METHODS Measurements of total IgE, allergen-specific IgE to 6 common allergens, and spirometry (forced expiratory volume in one second [FEV(1)], forced vital capacity [FVC], FEV(1)/FVC, and percent change in FEV(1) after bronchodilation) were used to calculate correlations between the logarithmically transformed IgE values and measures of lung function among participants in a birth cohort not selected for risk of allergic disease stratified by current asthma, prior asthma, or no asthma. RESULTS The 428 participants were 51.6% female, 93% white, and 18.4 (standard deviation = 0.6) years old. Forty-eight (11.2%) had current asthma, 55 (12.9%) had a history of asthma, and 325 (75.9%) never had asthma. For males with current asthma, correlations between total IgE and FEV(1)% and FVC% were -0.51 (P = .06) and -0.70 (P = .005), respectively. For females with current asthma, the only significant correlation was between total IgE and the FEV(1)/FVC ratio (-0.55, P = .001). After excluding smokers and individuals without detectable allergen-specific IgE, the negative correlations for both males and females remained statistically significant. The correlations among males or females with prior asthma or no history of asthma were minimal and not statistically significant. The sum of the allergen-specific IgEs showed the same pattern of relationships to lung function as did total IgE. CONCLUSION Our results show significant negative correlations that vary by gender between both total and allergen-specific IgE and measurements of lung function in young adults with current asthma.
Collapse
|
16
|
Kamemura N, Tada H, Shimojo N, Morita Y, Kohno Y, Ichioka T, Suzuki K, Kubota K, Hiyoshi M, Kido H. Intrauterine sensitization of allergen-specific IgE analyzed by a highly sensitive new allergen microarray. J Allergy Clin Immunol 2012; 130:113-21.e2. [PMID: 22464644 DOI: 10.1016/j.jaci.2012.02.023] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2011] [Revised: 01/24/2012] [Accepted: 02/15/2012] [Indexed: 10/28/2022]
Abstract
BACKGROUND To design a rational allergy prevention program, it is important to determine whether allergic sensitization starts in utero under the maternal immune system. OBJECTIVE To investigate the origin of allergen-specific IgE antibodies in cord blood (CB) and maternofetal transfer of immunoglobulins. METHODS The levels of food and inhalant allergen-specific IgE, IgA, IgG, and IgG(4) antibodies in CB and maternal blood (MB) from 92 paired neonates and mothers were measured by using a novel allergen microarray of diamond-like-carbon-coated chip, with high-sensitivity detection of allergen-specific antibodies and allergen profiles. RESULTS The levels of allergen-specific IgE antibodies against food and inhalant allergens and allergen profiles were identical in CB and newborn blood, but the levels and profiles, specifically against inhalant allergens, were different from those in MB. The level of allergen-specific IgA antibodies was below the detection levels in CB despite clear detection in MB. Therefore, contamination with MB in CB was excluded on the basis of extremely low levels of IgA antibodies in CB and the obvious mismatch of the allergen-specific IgE and IgA profiles between CB and MB. However, the levels of allergen-specific IgG and IgG(4) antibodies and their allergen profiles were almost identical in both MB and CB. CONCLUSION Allergen-specific levels of IgE and IgA antibodies and their allergen profiles analyzed by the diamond-like-carbon allergen chip indicate that IgE antibodies in CB are of fetal origin. Food-allergen specific IgE antibodies were detected more often than inhalant-allergen specific IgE antibodies in CB, the reason of which remains unclarified.
Collapse
Affiliation(s)
- Norio Kamemura
- Division of Enzyme Chemistry, Institute for Enzyme Research, University of Tokushima, Tokushima, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Different implications of paternal and maternal atopy for perinatal IgE production and asthma development. Clin Dev Immunol 2012; 2012:132142. [PMID: 22272211 PMCID: PMC3261469 DOI: 10.1155/2012/132142] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2011] [Accepted: 10/03/2011] [Indexed: 12/16/2022]
Abstract
Asthma is a hereditary disease associated with IgE-mediated reaction. Whether maternal atopy and paternal atopy have different impacts on perinatal IgE production and asthma development remains unclear. This paper reviews and summarizes the effects of maternal and paternal atopy on the developmental aspects of IgE production and asthma. Maternal atopy affects both pre- and postnatal IgE production, whereas paternal atopy mainly affects the latter. Maternally transmitted genes GSTP1 and FceRI-beta are associated with lung function and allergic sensitization, respectively. In IgE production and asthma development, the maternal influence on gene-environment interaction is greater than paternal influence. Maternal, paternal, and/or postnatal environmental modulation of allergic responses have been linked to epigenetic mechanisms, which may be good targets for early prevention of asthma.
Collapse
|
18
|
Bønnelykke K, Pipper CB, Bisgaard H. Transfer of maternal IgE can be a common cause of increased IgE levels in cord blood. J Allergy Clin Immunol 2010; 126:657-63. [PMID: 20816197 DOI: 10.1016/j.jaci.2010.06.027] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2009] [Revised: 06/20/2010] [Accepted: 06/22/2010] [Indexed: 11/25/2022]
Abstract
BACKGROUND IgE in cord blood is thought to be a product of the fetus. A high level of total IgE is therefore used as a measure of atopic propensity in the newborn. We recently found strong evidence that allergen-specific IgE in cord blood was the result of transfer of maternal IgE to fetal blood or cord blood (maternofetal transfer) rather than fetal production. This also suggests that total IgE in cord blood might primarily be a maternal product. OBJECTIVE We sought to determine to what extent increased levels of total IgE in cord blood is the result of maternofetal transfer of IgE. METHODS Total IgE in cord blood was analyzed in a prospective birth cohort study. Maternofetal transfer of IgE was detected by means of high-sensitivity analyses of cord blood IgA and allergen-specific IgE and comparison with parental IgE levels and levels at 6 months of age. RESULTS Forty-six percent of cord blood samples with increased IgE levels (>or=0.5 IU/mL) showed indication of maternofetal transfer of IgE. Maternal origin of IgE in these samples was validated by showing reduced levels of IgE at 6 months of age compared with samples with no indication of maternofetal transfer (geometric mean, 9.4 vs 5.4 IU/mL; P = .01). Maternofetal transfer was not appropriately accounted for by the conventional method of cord blood IgA measurement. CONCLUSIONS Maternofetal transfer might be a common cause of increased cord blood IgE levels. Future studies should take potential maternofetal transfer into account or use other markers of atopy.
Collapse
Affiliation(s)
- Klaus Bønnelykke
- Copenhagen Prospective Studies on Asthma in Childhood, Danish Pediatric Asthma Center, Health Sciences, University of Copenhagen, Copenhagen University Hospital, Gentofte, Copenhagen, Denmark
| | | | | |
Collapse
|
19
|
Rindsjö E, Joerink M, Johansson C, Bremme K, Malmström V, Scheynius A. Maternal allergic disease does not affect the phenotype of T and B cells or the immune response to allergens in neonates. Allergy 2010; 65:822-30. [PMID: 19930231 DOI: 10.1111/j.1398-9995.2009.02266.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND It is hypothesized that the in utero environment in allergic mothers can affect the neonatal immune responses. The aim of this study was to analyse the effect of maternal allergic disease on cord blood mononuclear cell (CBMC) phenotype and proliferative responses upon allergen stimulation. METHODS Peripheral blood mononuclear cells (PBMC) from 12 allergic and 14 nonallergic mothers and CBMC from their children were analysed. In the mothers, we determined cell proliferation, production of IL-4 and expression of FOXP3 in response to allergen stimulation. In the children, we evaluated cell proliferation and FOXP3 expression following allergen stimulation. Furthermore, expression of different homing markers on T cells and regulatory T cells and maturity of the T cells and B cell subsets were evaluated directly ex vivo. RESULTS The timothy- and birch-allergic mothers responded with increased proliferation and/or IL-4 production towards timothy and birch extract, respectively, when compared to nonallergic mothers. This could not be explained by impairment of FOXP3(+) regulatory T cells in the allergic mothers. CBMC proliferation and FOXP3 expression in response to allergens were not affected by the allergic status of the mother. Also, phenotype of T cells, FOXP3(+) regulatory T cells and B cells was not affected by the allergic status of the mother. CONCLUSION Our results suggest that maternal allergic disease has no effect on the neonatal response to allergens or the phenotype of neonatal lymphocytes. The factors studied here could, however, still affect later development of allergy.
Collapse
Affiliation(s)
- E Rindsjö
- Department of Medicine Solna, Clinical Allergy Research Unit, Karolinska University Hospital Solna and Karolinska Institutet, Stockholm, Sweden
| | | | | | | | | | | |
Collapse
|
20
|
Joerink M, Rindsjö E, Stenius F, Alm J, Lilja G, Grönlund H, Scheynius A. Evidence for allergen-specific IgE of maternal origin in human placenta. Allergy 2009; 64:905-12. [PMID: 19220215 DOI: 10.1111/j.1398-9995.2009.01941.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
BACKGROUND Immunoglobulin E (IgE) has been identified on macrophage-like cells in the villi of human placenta, irrespective of the serum IgE levels or allergy status of the mother. The origin of placental IgE is debated and it is not known if it is spontaneously produced, so-called 'natural IgE', or if it has any specificity for certain allergens. The aim of this study was to investigate if placental IgE originates from mother or child and to analyse its specificity. METHODS Immunoglobulin E was eluted from placenta by lowering the pH. Total and allergen-specific IgEs were measured in placenta eluate, maternal and cord blood plasma by means of ImmunoCAP (Phadia AB). The levels of natural antibodies were determined with an anti-phosphorylcholine (PC) enzyme-linked immunosorbent assay, as natural IgE has been shown in one previous publication with this assay. RESULTS Detectable amounts of IgE were eluted from 11/12 full-term placentas. Natural (anti-PC) IgE antibodies were detected in low amounts in maternal plasma but not in the placental eluate or in cord blood plasma. There was a significant correlation between the amount of total IgE eluted from placenta and the levels of total IgE in maternal plasma; however, not between maternal and cord blood plasma. Allergen-specific IgE was only found in placental eluates from mothers with specific IgE towards these allergens. Furthermore, there was a significant correlation between the amount of allergen-specific IgE eluted from placenta and the levels of allergen-specific IgE in maternal plasma. Allergen-specific IgE could not be detected in cord blood. CONCLUSION These results suggest a maternal origin of placental IgE, which can be allergen-specific.
Collapse
Affiliation(s)
- M Joerink
- Clinical Allergy Research Unit, Department of Medicine Solna, Stockholm, Sweden
| | | | | | | | | | | | | |
Collapse
|
21
|
Peters JL, Suglia SF, Platts-Mills TAE, Hosen J, Gold DR, Wright RJ. Relationships among prenatal aeroallergen exposure and maternal and cord blood IgE: project ACCESS. J Allergy Clin Immunol 2009; 123:1041-6. [PMID: 19361844 DOI: 10.1016/j.jaci.2009.02.027] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2008] [Revised: 02/16/2009] [Accepted: 02/17/2009] [Indexed: 01/16/2023]
Abstract
BACKGROUND Whereas some evidence suggests that antigen sensitization may begin prenatally, the influence of maternal allergen exposure during pregnancy has not been fully elucidated. OBJECTIVES We examined the relationship between prenatal maternal aeroallergen exposure and cord blood total IgE and the potential mediating/indirect effect of maternal immune response. METHODS This study was performed in 301 mother-infant pairs enrolled in the Asthma Coalition on Community, Environment, and Social Stress (ACCESS) project, a study examining the effects of prenatal and early life social and physical environmental exposures on urban asthma risk. Dust samples collected prenatally from mothers' bedrooms were analyzed for cockroach and dust mite allergens. Cord blood was analyzed for total IgE, and maternal serum collected during pregnancy for total and specific IgE. We assessed the relationship between prenatal exposure and cord blood total IgE and the potential mediation effect adjusting for maternal age, race, education, smoking status, and dust collection season; and child's sex and season of birth. RESULTS In multivariate models, elevated prenatal dust mite levels (>0.2 microg/g) increased cord blood IgE concentrations by 29% (P = .08), and continuous dust mite concentration was associated with a significant nonlinear increase in cord blood IgE (P = .02). Elevated prenatal exposure to cockroach allergen (>2 U/g) was not associated with cord blood IgE, but showed a significant indirect relationship through maternal total IgE (beta = 0.23; 95% CI, 0.08-0.41). CONCLUSION These results demonstrate that maternal prenatal exposure to household allergens may affect cord blood IgE, albeit the underlying mechanism may be allergen-specific.
Collapse
Affiliation(s)
- Junenette L Peters
- Department of Environmental Health, Harvard School of Public Health, Boston, Mass 02215, USA
| | | | | | | | | | | |
Collapse
|
22
|
Pesonen M, Kallio MJT, Siimes MA, Elg P, Björksten F, Ranki A. Cord serum immunoglobulin E as a risk factor for allergic symptoms and sensitization in children and young adults. Pediatr Allergy Immunol 2009; 20:12-8. [PMID: 18298422 DOI: 10.1111/j.1399-3038.2008.00736.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Early markers of atopic predisposition are needed for targeting allergy preventive measures to high-risk infants. An elevated cord serum immunoglobulin E (CS-IgE) level is considered a risk factor for subsequent allergy in childhood. However, the previous studies have not assessed the predictive value of CS-IgE in a follow-up extended to adulthood. We aimed at clarifying whether CS-IgE is useful in predicting subsequent atopic manifestations up to age 20 yr. A cohort of 200 unselected, full-term newborns were prospectively followed up from birth to age 20 yr. The CS-IgE level was successfully measured in 190 subjects at birth. The subjects were re-examined at ages of 5, 11 and 20 yr with assessment of the occurrence of allergic symptoms during the preceding year, skin prick testing and measurement of serum total IgE. An elevated CS-IgE level was associated with allergic symptoms and skin prick test positivity at age 5 yr (p = 0.03 and 0.01), with allergic rhinoconjunctivitis at age 20 yr (p = 0.04) and with an elevated serum total IgE at ages of 11 and 20 yr (p = 0.02 and 0.01). The sensitivity of CS-IgE, i.e. the probability of an elevated CS-IgE in an infant who subsequently develops atopy, in predicting skin prick test-verified atopy at ages of 5 and 20 yr was 50% and 26%, respectively. The combination of elevated CS-IgE and positive family history of allergy was strongly associated with subsequent atopic manifestations. Nevertheless, it showed a reduced sensitivity as compared to CS-IgE or family history of allergy. We conclude that an elevated CS-IgE level predicts subsequent atopy up to age 20 yr.
Collapse
Affiliation(s)
- Maria Pesonen
- Department of Dermatology, Skin and Allergy Hospital, Helsinki University Hospital, Helsinki, Finland.
| | | | | | | | | | | |
Collapse
|
23
|
Prenatal versus postnatal priming of allergen specific immunologic memory: the debate continues. J Allergy Clin Immunol 2008; 122:717-718. [PMID: 19014763 DOI: 10.1016/j.jaci.2008.08.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2008] [Accepted: 08/19/2008] [Indexed: 01/08/2023]
|
24
|
Cord blood allergen-specific IgE is associated with reduced IFN-gamma production by cord blood cells: the Protection against Allergy-Study in Rural Environments (PASTURE) Study. J Allergy Clin Immunol 2008; 122:711-716. [PMID: 18718651 DOI: 10.1016/j.jaci.2008.06.035] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2008] [Revised: 06/19/2008] [Accepted: 06/24/2008] [Indexed: 11/20/2022]
Abstract
BACKGROUND It is currently discussed whether allergic sensitization may start in utero under the influence of the maternal immune system and environmental determinants. OBJECTIVE To investigate the relationship between allergen-specific cord blood (CB) IgE levels, parental sensitization, CB cytokine production, and environmental influences. METHODS As part of an ongoing multicenter birth cohort study, allergen-specific IgE antibodies against 20 common seasonal, perennial, and food allergens were measured in blood samples from 922 neonates, 922 mothers, and 835 fathers. Supernatants from stimulated CB cells were assessed for the production of IL-5, IFN-gamma, IL-10, and TNF-alpha. RESULTS Allergen-specific IgE antibodies were detectable in 23.9% of newborns. Contamination with maternal serum was excluded by several means of analyses, including the absence of IgA antibodies. Clear correlation between maternal and fetal IgE was found only for hen's egg, cow's milk, and soybean allergen. Fetal IgE correlated negatively with the level of IFN-gamma production, but not with IL-5 and IL-10. CONCLUSION Allergen-specific IgE antibodies most probably of fetal origin are detectable in CB and correlate with a lowered CB IFN-gamma production.
Collapse
|
25
|
Bønnelykke K, Pipper CB, Bisgaard H. Sensitization does not develop in utero. J Allergy Clin Immunol 2008; 121:646-51. [PMID: 18328892 DOI: 10.1016/j.jaci.2007.12.1149] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2007] [Revised: 11/29/2007] [Accepted: 12/10/2007] [Indexed: 11/29/2022]
Abstract
BACKGROUND Intrauterine sensitization has been suggested to play a role in the development of atopic disease in children, and this has led to current guidelines recommending allergen avoidance during pregnancy. OBJECTIVE To investigate the relevance of allergen-specific IgE in cord blood to sensitization in early infancy and the origin of such IgE. METHODS Inhalant and food allergen-specific IgE in cord blood was analyzed and compared with specific IgE in infant blood at 6 months of age and in parental blood. Cord blood IgA was measured to detect maternal blood contamination of cord blood. RESULTS Allergen-specific IgE, primarily against inhalant allergens, was detected in 14% of cord blood samples. However, corresponding specific IgE was not found in infant blood at 6 months of age. Specific IgE in cord blood completely matched specific IgE in maternal blood with respect to allergen specificity, level of specific IgE, and ratio of total IgE/specific IgE. Finally, there was a correlation between specific IgE and IgA in cord blood. CONCLUSION Allergen-specific IgE in cord blood does not reflect intrauterine sensitization but seems to be the result of transfer of maternal IgE to the fetus.
Collapse
Affiliation(s)
- Klaus Bønnelykke
- Danish Pediatric Asthma Center, Department of Pediatrics, Copenhagen University Hospital, Copenhagen, Denmark.
| | | | | |
Collapse
|
26
|
Bertino E, Bisson C, Martano C, Coscia A, Fabris C, Monti G, Testa T, Conti A. Relationship between maternal- and fetal-specific IgE. Pediatr Allergy Immunol 2006; 17:484-8. [PMID: 17014621 DOI: 10.1111/j.1399-3038.2006.00449.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
AIM A positive correlation between maternal and cord-blood IgE levels is well documented for total IgEs, but not for specific IgEs. The difficulty in detecting specific cord-blood IgEs is due to their low concentrations, which hinder their dosage by low-sensitivity methods. The study aimed to correlate maternal and foetal specific IgEs against individual cow's milk proteins, detected by highly sensitive and specific techniques. METHODS Cow's milk specific IgE detection was performed by chemiluminescence on 52 specimens of maternal and cord blood after cow's milk protein separation by 1D and 2D gel electrophoresis. Cow's milk protein (CMP) antigens were identified by mass spectrometry techniques. RESULTS Specific IgEs for CMPs were found in 25/52 (48.1%) of maternal sera and in 19/52 (37%) of cord-blood sera. In order of decreasing frequency, the proteins found were BSA, IgG heavy chain, caseins and, in a single case, b-lactoglobulin. Positive cord-blood sera in all cases corresponded to a positive maternal result, and maternal and foetal immunoreactivity patterns were closely correlated. Moreover, in no case was there a positive cord-blood response with a negative maternal response. CONCLUSION The study demonstrates a close relationship between maternal and cord-blood specific IgE patterns. The phenomenon observed could provide a model to elucidate the general production method of foetal IgEs, which might only be produced in the presence of both the corresponding maternal IgE and the related allergen.
Collapse
Affiliation(s)
- Enrico Bertino
- Neonatal Unit, Department of Pediatric Sciences, University of Turin, Piazza Polonia 94, Turin, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Legg JP, Jones CA, Warner JA, Johnston SL, Warner JO. A hypothesis: antenatal sensitisation to respiratory syncytial virus in viral bronchiolitis. Arch Dis Child 2002; 86:431-3. [PMID: 12023178 PMCID: PMC1763017 DOI: 10.1136/adc.86.6.431] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
AIM To investigate the possibility of antenatal sensitisation to respiratory syncytial virus (RSV). METHODS A total of 36 cord blood specimens were obtained from newborn infants; serum IgA was measured to exclude maternal blood contamination. Cord peripheral blood mononuclear cells were separated and cultured in the presence of either uninfected negative control cells or cells containing ultraviolet (UV) inactivated RSV. Proliferation was assessed by tritiated thymidine incorporation. Supernatant cytokine concentrations were measured using ELISA. RESULTS Significantly higher proliferative response rates to UV inactivated RSV were shown in those infants exposed in utero to the RSV epidemic after 22 weeks gestation. UV inactivated RSV stimulation induced significantly higher interferon gamma production from specimens with a positive proliferative response (sensitised) than from those with a negative response (not sensitised). CONCLUSIONS Antenatal sensitisation to RSV occurs in one third of infants exposed to an RSV epidemic at the appropriate time of gestation. This sensitisation is associated with increased interferon gamma production, suggesting a type 1 memory response. We hypothesise that priming of fetal T cells to RSV results in a reduced severity of subsequent RSV disease in these individuals and that this will explain much of the clinical diversity of RSV disease.
Collapse
Affiliation(s)
- J P Legg
- Department of Child Health, University of Southampton, Southampton, UK.
| | | | | | | | | |
Collapse
|