1
|
Lehrkinder A, Rydholm O, Wänström A, Nakamura K, Örtengren U. The formation of cariogenic plaque to contemporary adhesive restorative materials: an in vitro study. Odontology 2024; 112:1090-1102. [PMID: 38502470 DOI: 10.1007/s10266-024-00913-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 02/07/2024] [Indexed: 03/21/2024]
Abstract
The research exploiting the ability of dental materials to induce or prevent secondary caries (SC) development still seems inconclusive. Controlling bacterial adhesion by releasing bacteriostatic ions and improving the surface structure has been suggested to reduce the occurrence of SC. This paper analyses the impact of five distinctively composed dental materials on cariogenic biofilm formation. Forty-five specimens of three composites (CeramX Spectra ST, Admira Fusion, Beautifil II) and two glass-ionomers (Fuji II LC, Caredyne Restore), respectively, were incubated in bacterial suspension composed of Streptococcus mutans, Lactobacillus acidophilus, Streptococcus mitis, Streptococcus sanguinis, and Streptococcus salivarius at pH 7.0 and 5.5. Coverslips were used as a control. Adhered bacteria were collected after 2, 4, 6, 12, 24, and 48 h and analyzed using quantitative polymerase chain reaction (qPCR). Fluoride leakage was measured at each collection. The specimens' surface topography was assessed using interferometry. In the present study, surface roughness seemed to have a partial role in bacterial adhesion and biofilm formation, together with chemical composition of the materials tested. Despite differences in fluoride leakage, biofilm accumulation was similar across materials, but the number of adhered bacteria differed significantly. A release of other ions may also affect adhesion. These variations suggest that certain materials may be more prone to initiating secondary caries.
Collapse
Affiliation(s)
- Anna Lehrkinder
- Department of Cariology, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Box 450, 405 30, Göteborg, Sweden
| | - Olivia Rydholm
- Department of Cariology, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Box 450, 405 30, Göteborg, Sweden
| | - Anna Wänström
- Department of Cariology, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Box 450, 405 30, Göteborg, Sweden
| | - Keisuke Nakamura
- Department of Advanced Free Radical Science, Tohoku University Graduate School of Dentistry, Sendai, Japan
| | - Ulf Örtengren
- Department of Cariology, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Box 450, 405 30, Göteborg, Sweden.
- Department of Material Science and Technology, Faculty of Odontology, Malmö University, Malmö, Sweden.
| |
Collapse
|
2
|
Kitaygorodskiy A, Gregory RL, Lim G, Hamada Y. In Vitro Comparison of Titanium Disc Surface Roughness and Bacterial Colonization After Ultrasonic Instrumentation With Three Different Tips. J ORAL IMPLANTOL 2024; 50:537-543. [PMID: 39023858 DOI: 10.1563/aaid-joi-d-24-00049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/20/2024]
Abstract
During implant maintenance, preserving a smooth surface on the machined transmucosal abutment is critical to reduce biofilm attachment and colonization. The present study compared the surface roughness and bacterial colonization of machined titanium surfaces after instrumentation with various materials. Forty-four machined grade 23 titanium discs were instrumented with a round polyether ether ketone (PEEK) tip, a plastic curette tip, or a pure titanium curette tip with piezoelectric devices. Before and after instrumentation, the surface roughness (Ra and Rz) values were analyzed with a profilometer and scanning electron microscopy (SEM). Streptococcus sanguinis was cultured and incubated for 24 hours on the instrumented discs, and colony-forming units per milliliter were obtained for each group. Samples instrumented with the metal ultrasonic tip significantly increased surface roughness compared with the other groups. This resulted in greater colonization by S. sanguinis than surfaces instrumented with PEEK tips or the negative control. Samples instrumented with PEEK and plastic tips did not exhibit any statistically significant increase in surface roughness, and SEM analysis revealed a significantly rougher surface of discs instrumented with metal compared with discs instrumented with plastic or PEEK tips despite the possibility of debris from tip dissolution. Our results suggest that instrumentation with metal ultrasonic tips with piezoelectric devices significantly increased machined titanium's surface roughness and elicited higher biofilm formation in vitro. Meanwhile, instrumentation of machined titanium with PEEK or plastic ultrasonic tips did not affect the surface roughness or bacterial adhesion.
Collapse
Affiliation(s)
| | - Richard L Gregory
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, Indiana
| | | | - Yusuke Hamada
- Section of Periodontics, UCLA School of Dentistry, Los Angeles, California
| |
Collapse
|
3
|
Bunz O, Diekamp M, Bizhang M, Testrich H, Piwowarczyk A. Surface roughness associated with bacterial adhesion on dental resin-based materials. Dent Mater J 2024; 43:621-628. [PMID: 39218688 DOI: 10.4012/dmj.2023-234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
This study investigates the surface quality and bacterial adhesion properties of various dental materials, including indirect composites, veneering composites, direct composites, polyether ether ketone (PEEK), and two millable polymethyl methacrylate (PMMA). Material specimens were processed following manufacturer instructions, initially evaluated for surface roughness and Streptococcus sanguinis (S. sanguinis) adhesion. Subsequently, toothbrushing simulation was employed to simulate aging, and changes in material surfaces were assessed via roughness measurements and bacterial adhesion testing. Prior to simulated aging, direct and indirect composites exhibited the lowest roughness values. However, after the simulated toothbrushing, veneering composites displayed the highest roughness levels. Both PMMA materials demonstrated the highest S. sanguinis adhesion levels, both before and after artificial aging. Interestingly, the indirect composite material showed a reduction in bacterial adhesion following toothbrushing simulation. Surprisingly, this study did not reveal a clear correlation between roughness and bacterial adhesion.
Collapse
Affiliation(s)
- Oskar Bunz
- Department of Prosthodontics, Faculty of Health, School of Dentistry, Witten/Herdecke University
| | | | - Mozhgan Bizhang
- Department of Operative and Preventive Dentistry, Faculty of Health, School of Dentistry, Witten/Herdecke University
| | | | - Andree Piwowarczyk
- Department of Prosthodontics, Faculty of Health, School of Dentistry, Witten/Herdecke University
| |
Collapse
|
4
|
Gnilitskyi I, Dolgov L, Tamm A, Ferraria AM, Diedkova K, Kopanchuk S, Tsekhmister Y, Veiksina S, Polewczyk V, Pogorielov M. Enhanced osteointegration and osteogenesis of osteoblast cells by laser-induced surface modification of Ti implants. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2024; 62:102785. [PMID: 39306023 DOI: 10.1016/j.nano.2024.102785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 08/24/2024] [Accepted: 09/10/2024] [Indexed: 09/28/2024]
Abstract
Dental and orthopedic implants have become routine medical technologies for tooth replacement and bone fixation. Despite significant progress in implantology, achieving sufficient osseointegration remains a challenge, often leading to implant failure over the long term. Nanotechnology offers the potential to mimic the natural patterns of living tissues, providing a promising platform for tissue engineering and implant surface design. Among the various methods for developing nanostructures, High-Regular Laser-Induced Periodic Surface Structures (HR-LIPSS) techniques stand out for their ability to fabricate highly ordered nanostructures with excellent long-range repeatability and production efficiency. In this study, we utilized an innovative technical approach to generate traditional laser-induced superficial LIPSS nanostructures, followed by detailed surface analysis using classical microscopy and physicochemical methods. Our findings demonstrate for the first time that nanostructured LIPSS surfaces can significantly enhance cell adhesion and proliferation while providing an optimal environment for cell metabolism. Given the high reproducibility, low cost, and potential of HR-LIPSS techniques to support cell growth and differentiation, this novel technology has the potential to impact both the industrial development of new implants and clinical outcomes after implantation.
Collapse
Affiliation(s)
- Iaroslav Gnilitskyi
- NoviNano Inc., 5 Pasternaka Str., 79015 Lviv, Ukraine; Department of Applied Physics and Nanomaterials Science, Lviv Polytechnic National University, 12, S.Bandera Str, 79013 Lviv, Ukraine.
| | - Leonid Dolgov
- Institute of Physics, University of Tartu, 1 Ostwaldi str., 50411 Tartu, Estonia
| | - Aile Tamm
- Institute of Physics, University of Tartu, 1 Ostwaldi str., 50411 Tartu, Estonia
| | - Ana Maria Ferraria
- BSIRG-iBB-Institute for Bioengineering and Biosciences, Universidade de Lisboa, Alameda da Universidade, 1049-001 Lisbon, Portugal; Associate Laboratory i4HB-Institute for Health and Bioeconomy at Instituto Superior Técnico, Universidade de Lisboa, Alameda da Universidade, 1049-001 Lisboa, Portugal
| | - Kateryna Diedkova
- Biomedical Research Centre, Sumy State University, R-Korsakova Str., 40007 Sumy, Ukraine; Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas Str., LV-1004 Riga, Latvia
| | - Sergei Kopanchuk
- Institute of Chemistry, University of Tartu, 14a Ravila str., 50411 Tartu, Estonia
| | - Yaroslav Tsekhmister
- Ukrainian Medical Lyceum at O.O. Bogomolets National Medical University, 13/7 Tarasa Shevchenko Blvd, Kyiv, Ukraine
| | - Santa Veiksina
- Institute of Physics, University of Tartu, 1 Ostwaldi str., 50411 Tartu, Estonia
| | - Vincent Polewczyk
- Université deVersailles Saint-Quentin en Yvelines & CNRS, 78035 Versailles, France
| | - Maksym Pogorielov
- Biomedical Research Centre, Sumy State University, R-Korsakova Str., 40007 Sumy, Ukraine; Institute of Atomic Physics and Spectroscopy, University of Latvia, Jelgavas Str., LV-1004 Riga, Latvia.
| |
Collapse
|
5
|
Bakitian FA. A Comprehensive Review of the Contemporary Methods for Enhancing Osseointegration and the Antimicrobial Properties of Titanium Dental Implants. Cureus 2024; 16:e68720. [PMID: 39238921 PMCID: PMC11376426 DOI: 10.7759/cureus.68720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/05/2024] [Indexed: 09/07/2024] Open
Abstract
Titanium dental implants with various restorative options are popular for replacing missing teeth due to their comfortable fit, excellent stability, natural appearance, and impressive track record in clinical settings. However, challenges such as potential issues with osseointegration, peri-implant bone loss, and peri-implantitis might lead to implant failure, causing concern for patients and dental staff. Surface modification has the potential to significantly enhance the success rate of titanium implants and meet the needs of clinical applications. This involves the application of various physical, chemical, and bioactive coatings, as well as adjustments to implant surface topography, offering significant potential for enhancing implant outcomes in terms of osseointegration and antimicrobial properties. Many surface modification methods have been employed to improve titanium implants, showcasing the diversity of approaches in this field including sandblasting, acid etching, plasma spraying, plasma immersion ion implantation, physical vapor deposition, electrophoretic deposition, electrochemical deposition, anodization, microarc oxidation, laser treatments, sol-gel method, layer-by-layer self-assembly technology, and the adsorption of biomolecules. This article provides a comprehensive overview of the surface modification methods for titanium implants to address issues with insufficient osseointegration and implant-related infections. It encompasses the physical, chemical, and biological aspects of these methods to provide researchers and dental professionals with a robust resource to aid them in their study and practical use of dental implant materials, ensuring they are thoroughly knowledgeable and well-prepared for their endeavors.
Collapse
Affiliation(s)
- Fahad A Bakitian
- Department of Restorative Dentistry, Faculty of Dental Medicine, Umm Al-Qura University, Makkah, SAU
| |
Collapse
|
6
|
Shah SD, Zheng F, Seghi RR, Lee DJ. Strength of titanium-zirconium alloy implants with a conical connection after implantoplasty. J Prosthet Dent 2024; 132:593-599. [PMID: 36150928 DOI: 10.1016/j.prosdent.2022.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 08/04/2022] [Accepted: 08/05/2022] [Indexed: 10/14/2022]
Abstract
STATEMENT OF PROBLEM Peri-implantitis occurs around dental implants, and implantoplasty has been used to address this ongoing disease; however, the changes to the physical properties of an implant after implantoplasty have not been well documented. PURPOSE The purpose of this in vitro study was to determine the effect of implantoplasty on fracture strength and the load required for plastic deformation after cyclic fatigue on dental implants. MATERIAL AND METHODS Twenty-six titanium/zirconium (TiZr) alloy implants (Roxolid Bone Level Implant; 4.1×10 mm) were embedded with 50% thread exposure and divided into 4 groups based on whether they had implantoplasty treatment by using different diamond rotary instruments and/or cyclic loading at 250 N for 2 million cycles: C0 (control, no cyclic loading), T0 (test, no cyclic loading), CM (control, cyclic loading), and TM (test, cyclic loading). After implantoplasty and/or cyclic loading, all implants underwent a load-to-failure test. The maximum fracture strength (FS) and load required for the onset of plastic deformation (PD) were recorded in Newtons. One-way ANOVA and nonparametric comparisons with control by using the Dunn and Wilcoxon method for joint ranking were used for statistical analysis. RESULTS The mean ±standard deviation FS for C0, CM, T0, and TM was 1465.2 ±86.4 N, 1480.7 ±64.1 N, 1299.3 ±123.8 N, and 1252.1 ±85.7 N, respectively. The mean ±standard deviation load for onset of PD for C0, CM, T0, and TM was 860.2 ±88.1 N, 797.0 ±130.5 N, 776.5 ±181.8 N, and 631.3 ±84.5 N, respectively. The TM group had a significantly lower FS and PD than the C0, CM, and T0 groups (P<.05) CONCLUSIONS: Both fracture strength (FS) and the onset of plastic deformation (PD) were significantly reduced after a TiZr alloy implant received implantoplasty and cyclic loading.
Collapse
Affiliation(s)
- Sweety D Shah
- Former Resident, Advanced Prosthodontics Program, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio; Private practice, Charlotte, NC
| | - Fengyuan Zheng
- Associate Clinical Professor and Director, Advanced Education in Prosthodontics Program, Department of Restorative Sciences, Division of Prosthodontics, University of Minnesota School of Dentistry; Minneapolis, Minn
| | - Robert R Seghi
- Professor Emeritus, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
| | - Damian J Lee
- Associate Professor and Director, Advanced Prosthodontics Program, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio.
| |
Collapse
|
7
|
Cichos KH, Christie MC, Ponce BA, Ghanem ES. Biofilm Growth on Orthopaedic Cerclage Materials: Nonmetallic Polymers Are Less Resistant to Methicillin-Resistant Staphylococcus Aureus Bacterial Adhesion. J Arthroplasty 2024; 39:S469-S475.e1. [PMID: 38642854 DOI: 10.1016/j.arth.2024.04.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 04/11/2024] [Accepted: 04/12/2024] [Indexed: 04/22/2024] Open
Abstract
BACKGROUND Data on bacterial adhesion to cerclage cables are sparse. We aimed to compare 5 cerclage products for methicillin-resistant Staphylococcus aureus (MRSA) adhesion to determine the claim: Are nonmetallic polymer cables more resistant to bacterial adhesion than common metallic wires and cables? METHODS The following 5 cerclage products were compared: (1) monofilament stainless steel (SS) wires; (2) multifilament SS cables; (3) multifilament cobalt chrome cables; (4) multifilament Vitallium alloy (cobalt-chrome-molybdenum [Co-Cr-Mo]) cables; and (5) multifilament nonmetallic polymer cables. Each was cut into 2 cm lengths and placed into 12-well plates. Of the wells, 5 were wire or cables in trypticase soy broth with MRSA, with the remaining wells being appropriate controls incubated for 24 hours at 37° C and 5% CO2 with shaking. Wires and cables were prepared and randomly imaged via scanning electron microscopy, with bacterial counts performed on 3 images of 3 different wires or cables per study group. The scanning electron microscopy technician and counting investigator were blinded. Additionally, SS wire and polymer cables were analyzed by microcalorimetry for metabolic activity and bacterial load. RESULTS Bacterial attachment differed significantly between study groups in the middle section (P = .0003). Post hoc comparison showed no difference between groups individually (all P > .05) apart from polymer cables (median 551 bacteria) having significantly increased attached bacteria compared to the Vitallium alloy cable (157, P = .0004), SS cable (101, P = .0004), and SS wire (211, P = .0004). There was no difference between polymer and cobalt chrome cables (133, P = .056). Microcalorimetry supported these results, as polymer cables had a shorter time to max heat flow (6.2 versus 7.5 hours, P = .006), increased max heat flow (117 versus 64 uW, P = .045), and increased colony-forming units, indicating an increased bacterial load compared to SS wires. CONCLUSIONS This in vitro study demonstrated that polymer cables have increased MRSA adhesion compared to common metallic wires and cables. Future studies are necessary to confirm the translation of increased bacterial adherence on polymer cables to increased rates of orthopaedic infections.
Collapse
Affiliation(s)
- Kyle H Cichos
- Hughston Foundation, Columbus, Georgia; Hughston Clinic, Columbus, Georgia
| | | | | | - Elie S Ghanem
- Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri
| |
Collapse
|
8
|
Park WB, Okany KP, Park W, Han JY, Lim HC, Kang P. Atypical and Late-Developed Sinus Graft Complications Following Maxillary Sinus Augmentation: Successful Management with Guided Bone Regeneration. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1246. [PMID: 39202527 PMCID: PMC11355990 DOI: 10.3390/medicina60081246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 07/16/2024] [Accepted: 07/23/2024] [Indexed: 09/03/2024]
Abstract
Complications that occur after maxillary sinus floor augmentation (MSA) can be divided into early and late complications. Early complication is a side effect that occurs during the MSA procedure or during the initial healing period. Usually, late complication refers to a side effect that occurs after 3 weeks of MSA. However, in the longer term, there are cases that occur during the follow-up period after the prosthesis is delivered, and most of them present with peri-implantitis. In the present two cases, sinus graft complications occurred 1-2 years after prosthesis delivery but were independent of peri-implantitis and had atypical features showing asymptomatic results. Although the route of the infection source is unclear, the lesions were presumed to be caused by slow and delayed inflammation of oral bacteria infiltrating the bone graft area of the maxillary sinus. Within the limitations of present case reports, bone defects were successfully managed with a guided bone regeneration (GBR) procedure that included thorough defect degranulation, surface decontamination of exposed implant, and regrafting. Periodic monitoring of radiographic images is required for the detection of unusual sinus graft complications in sinus-augmented sites.
Collapse
Affiliation(s)
- Won-Bae Park
- Department of Periodontology, School of Dentistry, Kyung Hee University; Seoul 02447, Republic of Korea;
- Private Practice in Periodontics and Implant Dentistry, Seoul 02771, Republic of Korea
| | - Kenechi P. Okany
- Division of Periodontics, Section of Oral, Diagnostic and Rehabilitation Sciences Columbia University College of Dental Medicine, #PH7E-110, 630 W. 168 St., New York, NY 10032, USA;
| | - Wonhee Park
- Department of Dentistry, Division of Dentistry, College of Medicine, Hanyang University, Gyeongchun-ro, Guri-si 11923, Republic of Korea;
| | - Ji-Young Han
- Department of Periodontology, Division of Dentistry, College of Medicine, Hanyang University, 222-1 Wangsimni-ro, Seongdong-gu, Seoul 04763, Republic of Korea;
| | - Hyun-Chang Lim
- Department of Periodontology, Periodontal-Implant Clinical Research Institute, School of Dentistry, Kyunghee Daero 23, Dongdaemoon-gu, Seoul 02447, Republic of Korea
| | - Philip Kang
- Division of Periodontics, Section of Oral, Diagnostic and Rehabilitation Sciences Columbia University College of Dental Medicine, #PH7E-110, 630 W. 168 St., New York, NY 10032, USA;
| |
Collapse
|
9
|
Feng Z, Zhu J, Zhang L, Li C, Su D, Wang H, Yu Y, Song L. Microbiological and functional traits of peri-implant mucositis and correlation with disease severity. mSphere 2024; 9:e0005924. [PMID: 38980075 PMCID: PMC11287996 DOI: 10.1128/msphere.00059-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 06/05/2024] [Indexed: 07/10/2024] Open
Abstract
Osseointegrated dental implants replace missing teeth and create an artificial surface for biofilms of complex microbial communities to grow. These biofilms on implants and dental surfaces can trigger infection and inflammation in the surrounding tissue. This study investigated the microbial characteristics of peri-implant mucositis (PM) and explored the correlation between microbial ecological imbalance, community function, and disease severity by comparing the submucosal microflora from PM with those of healthy inter-subject implants and intra-subject gingivitis (G) within a group of 32 individuals. We analyzed submucosal plaques from PM, healthy implant (HI), and G sites using metagenome shotgun sequencing. The bacterial diversity of HIs was higher than that of PM, according to the Simpson index. Beta diversity revealed differences in taxonomic and functional compositions across the groups. Linear discriminant analysis of the effect size identified 15 genera and 37 species as biomarkers that distinguished PM from HIs. Pathways involving cell motility and protein processing in the endoplasmic reticulum were upregulated in PM, while pathways related to the metabolism of cofactors and vitamins were downregulated. Microbial dysbiosis correlated positively with the severity of clinical inflammation measured by the sulcus bleeding index (SBI) in PM. Prevotella and protein processing in the endoplasmic reticulum also correlated positively with the SBI. Our study revealed PM's microbiological and functional traits and suggested the importance of certain functions in disease severity.IMPORTANCEPeri-implant mucositis is an early stage in the progression of peri-implantitis. The high prevalence of it has been a threat to the widespread use of implant prosthodontics. The link between the submucosal microbiome and peri-implant mucositis was demonstrated previously. Nevertheless, the taxonomic and functional composition of the peri-implant mucositis microbiome remains controversial. In this study, we comprehensively characterize the microbial signature of peri-implant mucositis and for the first time, we investigate the correlations between microbial dysbiosis, functional potential, and disease severity. With the help of metagenomic sequencing, we find the positive correlations between microbial dysbiosis, genus Prevotella, pathway of protein processing in the endoplasmic reticulum, and more severe mucosal bleeding in the peri-implant mucositis. Our studies offer insight into the pathogenesis of peri-implant mucositis by providing information on the relationships between community function and disease severity.
Collapse
Affiliation(s)
- Ziying Feng
- Department of Stomatology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, China
| | - Jinzan Zhu
- Department of Stomatology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, China
| | - Limin Zhang
- Department of Stomatology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, China
| | - Chunchun Li
- Department of Stomatology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, China
| | - Duyao Su
- Department of Stomatology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, China
| | - Huihui Wang
- Department of Stomatology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, China
| | - Youcheng Yu
- Department of Stomatology, Zhongshan Hospital of Fudan University, Shanghai, China
| | - Liang Song
- Department of Stomatology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai, China
| |
Collapse
|
10
|
Dotta TC, D'Ercole S, Iezzi G, Pedrazzi V, Galo R, Petrini M. The Interaction between Oral Bacteria and 3D Titanium Porous Surfaces Produced by Selective Laser Melting-A Narrative Review. Biomimetics (Basel) 2024; 9:461. [PMID: 39194440 DOI: 10.3390/biomimetics9080461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Revised: 07/17/2024] [Accepted: 07/26/2024] [Indexed: 08/29/2024] Open
Abstract
The interaction between oral bacteria and dental implant surfaces is a critical factor in the success and longevity of dental implants. With advancements in additive manufacturing technologies, selective laser melting (SLM) has emerged as a prominent method for producing titanium implants with highly controlled microstructures and porosities. These 3D printed titanium surfaces offer significant benefits, such as enhanced osseointegration and improved mechanical properties. However, the same surface features that promote bone cell attachment and proliferation may also provide favorable conditions for bacterial adhesion and biofilm formation. Understanding the dynamics of these interactions is essential for developing implant surfaces that can effectively resist bacterial colonization while promoting tissue integration. This narrative review explores the complex interplay between oral bacteria and SLM-produced titanium porous surfaces, examining current research findings and potential strategies for optimizing implant design to mitigate the risks of infection and ensure successful clinical outcomes.
Collapse
Affiliation(s)
- Tatiane Cristina Dotta
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, São Paulo 14040-904, Brazil
| | - Simonetta D'Ercole
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy
| | - Giovanna Iezzi
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy
| | - Vinicius Pedrazzi
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, São Paulo 14040-904, Brazil
| | - Rodrigo Galo
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, São Paulo 14040-904, Brazil
| | - Morena Petrini
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, 66100 Chieti, Italy
| |
Collapse
|
11
|
Barutçugil Ç, Tayfun D, Çetin Tuncer N, Dündar A. Bacterial adhesion and surface properties of computer-aided design-computer-aided manufacturing restorative materials. J Oral Sci 2024; 66:157-162. [PMID: 38866551 DOI: 10.2334/josnusd.24-0056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
PURPOSE This study aimed to evaluate the surface properties and bacterial adhesion of computer-aided design-computer-aided manufacturing (CAD-CAM) restorative materials. METHODS Four CAD-CAM resin-based blocks (Vita Enamic, Shofu block HC, Cerasmart [CS] and Lava Ultimate [LU]) and a leucite-reinforced glass ceramic block (IPS Empress CAD) were used in the present study. Specimens prepared with dimensions of 10 × 10 × 1 mm were polished. Surface characteristics were assessed with hydrophobicity and surface free energy (SFE) analysis. Surface roughness was measured using a profilometer, and elemental and topographic evaluations were performed with SEM-EDX analysis. After being kept in artificial saliva for 1 h, Streptococcus mutans (S. mutans) and Streptococcus mitis (S. mitis) were incubated separately in 5% CO2 atmosphere at 37°C for 24 h. The adhered bacteria were counted as ×108 CFU/mL. RESULTS Surface roughness, contact angle and SFE measurement values were found to be in the range of 0.144-0.264 Ra, 28.362°-70.074° and 39.65-63.62 mN/m, respectively. The highest adhered amount of S. mutans was found in CS and the lowest in LU, while there was no significant difference between the amounts of adhered S. mitis. CONCLUSION Despite differences in the surface properties of the materials used for the study, the materials exhibited identical properties with respect to bacterial adhesion.
Collapse
Affiliation(s)
- Çağatay Barutçugil
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University
| | | | - Nurgül Çetin Tuncer
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University
| | - Ayşe Dündar
- Department of Restorative Dentistry, Faculty of Dentistry, Akdeniz University
| |
Collapse
|
12
|
Hussain B, Grytten JI, Rongen G, Sanz M, Haugen HJ. Surface Topography Has Less Influence on Peri-Implantitis than Patient Factors: A Comparative Clinical Study of Two Dental Implant Systems. ACS Biomater Sci Eng 2024; 10:4562-4574. [PMID: 38916970 PMCID: PMC11234333 DOI: 10.1021/acsbiomaterials.3c01809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 06/15/2024] [Accepted: 06/17/2024] [Indexed: 06/27/2024]
Abstract
OBJECTIVES This study aims to assess the risk of peri-implantitis (PI) onset among different implant systems and evaluate the severity of the disease from a population of patients treated in a university clinic. Furthermore, this study intends to thoroughly examine the surface properties of the implant systems that have been identified and investigated. MATERIAL AND METHODS Data from a total of six hundred and 14 patients were extracted from the Institute of Clinical Dentistry, Dental Faculty, University of Oslo. Subject- and implant-based variables were collected, including the type of implant, date of implant installation, medical records, recall appointments up to 2022, periodontal measurements, information on diabetes, smoking status, sex, and age. The outcome of interest was the diagnosis of PI, defined as the occurrence of bleeding on probing (BoP), peri-implant probing depth (PD) ≥ 5 mm, and bone loss (BL). Data were analyzed using multivariate linear and logistic regression. Scanning electron microscopy, light laser profilometer, and X-ray photoelectron spectroscopy were utilized for surface and chemical analyses. RESULTS Among the patients evaluated, 6.8% were diagnosed with PI. A comparison was made between two different implant systems: Dentsply Sirona, OsseospeedTM and Straumann SLActive, with mean follow-up times of 3.84 years (SE: 0.15) and 3.34 years (SE: 0.15), respectively. The surfaces have different topographies and surface chemistry. However, no significant association was found between PI and implant surface/system, including no difference in the onset or severity of the disease. Nonetheless, plaque control was associated with an increased risk of developing PI, along with the gender of the patient. Furthermore, patients suffering from PI exhibited increased BL in the anterior region. CONCLUSION No differences were observed among the evaluated implant systems, although the surfaces have different topography and chemistry. Factors that affected the risk of developing PI were plaque index and male gender. The severity of BL in patients with PI was more pronounced in the anterior region. Consequently, our findings show that success in implantology is less contingent on selecting implant systems and more on a better understanding of patient-specific risk factors, as well as on implementing biomaterials that can more effectively debride dental implants.
Collapse
Affiliation(s)
- Badra Hussain
- Department
of Biomaterials, Institute of Clinical Dentistry, University of Oslo, Oslo 0316, Norway
| | | | - Gunnar Rongen
- Institute
of Community Dentistry, University of Oslo, Oslo 0316, Norway
| | - Mariano Sanz
- Section
of Periodontology, Faculty of Odontology, University Complutense of Madrid, Madrid 28040, Spain
- ETEP
(Etiology and Therapy of Periodiontal and Peri-Implant Diseases) Research
Group, Complutense University, Madrid 28040, Spain
| | - Håvard Jostein Haugen
- Department
of Biomaterials, Institute of Clinical Dentistry, University of Oslo, Oslo 0316, Norway
| |
Collapse
|
13
|
Phatphutthitham C, Niyatiwatchanchai B, Rujiraprasert P, Tagami J, Osathanon T, Srijunbarl A, Singthong T, Suriyasangpetch S, Nantanapiboon D. Effect of Grinding and Polishing Protocols on Surface Roughness, Flexural Strength, and Phase Transformation of High-Translucent 5 mol% Yttria-Partially Stabilized Zirconia. Eur J Dent 2024. [PMID: 38942054 DOI: 10.1055/s-0044-1787001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/30/2024] Open
Abstract
OBJECTIVES This study evaluated surface roughness, biaxial flexural strength, and phase transformation of 5Y-PSZ after grinding and polishing with different protocols. MATERIAL AND METHODS Two commercial 5Y-PSZ, Lava Esthetic (L) and Cercon xt (C), were used and divided into 3 groups: LC and CC represented unpolished control groups; LE and CE were polished with protocol I (EVE DIASYNT® PLUS HP following with EVE DIACERA RA); and LJ and CJ were polished with protocol II (Superfine diamond bur following with Jota ZIR Gloss polishing kit). Surface roughness was evaluated after polishing step-by-step with a contact-type profilometer. After high-gross polishing, the specimens were subjected to biaxial flexural strength test, crystallographic microstructure analysis using an X-ray diffractometer (XRD), and surface micro-topography using scanning electron microscopy (SEM). STATISTICAL ANALYSIS Surface roughness differences after each step and biaxial flexural strength between groups were evaluated with one-way ANOVA, followed by Bonferroni post-hoc analysis. Changes in surface roughness across four different time points within groups were assessed using one-way repeated measures ANOVA, followed by Bonferroni post-hoc analysis. RESULTS After high-gross polishing, both polishing protocols showed significantly lower surface roughness than the grinding group (p < 0.05). The LE and CE groups exhibited the highest surface roughness values, which were significant differences from the LJ and CJ groups (p < 0.05). The LE group showed significantly lower biaxial flexural strength compared to the LC group (p < 0.05). However, there was no statistically significant difference in the CE and CJ groups compared to the control group (p > 0.05). Furthermore, all polishing protocols did not change the phase transformation of zirconia. CONCLUSION Polishing protocol II provided a smoother surface than the protocol I after high-gross polishing, while the biaxial flexural strength of materials remained unaffected.
Collapse
Affiliation(s)
| | | | - Phakvalunch Rujiraprasert
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Junji Tagami
- Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, Thailand
| | - Thanaphum Osathanon
- Center of Excellence for Dental Stem Cell Biology, Department of Anatomy, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Anucharte Srijunbarl
- Dental Material Research and Development Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Thawanrat Singthong
- Dental Material Research and Development Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| | - Sarat Suriyasangpetch
- Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
| | - Dusit Nantanapiboon
- Department of Operative Dentistry, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Dental Material Research and Development Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
- Clinic of General, Special Care, and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
14
|
Târtea DA, Manolea HO, Ionescu M, Gîngu O, Amărăscu MO, Popescu AM, Mercuţ V, Popescu SM. A Microscopy Evaluation of Emergence Profile Surfaces of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments. J Pers Med 2024; 14:699. [PMID: 39063952 PMCID: PMC11278322 DOI: 10.3390/jpm14070699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 06/21/2024] [Accepted: 06/24/2024] [Indexed: 07/28/2024] Open
Abstract
Recently, due to the high demand for dental implants, the use of dental implant stock abutments has increased significantly, especially dental custom CAD/CAM implant abutments milled by dental technicians in their laboratories. The purpose of this study is to analyze the surface quality of the emergence profile of dental custom CAD/CAM implant abutments made by a non-industrial milling machine, compared to original and compatible dental implant stock abutments made by industrial machines. Thirty dental implant abutments were divided into six study lots. Lot 1 (control group): original dental implant stock abutments-industrial machined; lot 2 (study group): compatible dental implant stock abutments-industrial machined; lots 3, 4, 5, and 6 (study groups): compatible custom CAD/CAM dental implant abutments-non-industrial milled with hyperDENT CAM software and Paragon Tools. The Nikon SMZ745T stereomicroscope was used to analyze the emergence profile surface of each dental implant abutment. The structure of the analyzed surfaces did not show significant differences between original and compatible abutments that were industrially machined. As for the customized dental implant abutments, the greatest similarity with the original was obtained for lot 6, and a significant statistical difference was obtained for lot 4. Stepover and Feed Rate parameters of the milling process influenced the surface roughness of the emergence profile for the customized dental implant abutments. The digital technology of non-industrial milling compatible custom CAD/CAM dental implant abutments is reliable and within the correct milling parameters.
Collapse
Affiliation(s)
- Daniel Adrian Târtea
- Department of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania (S.M.P.)
| | - Horia Octavian Manolea
- Department of Dental Materials, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Mihaela Ionescu
- Department of Medical Informatics and Biostatistics, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
| | - Oana Gîngu
- Department of Engineering and Management of Technological Systems, Faculty of Mechanics, University of Craiova, 200512 Craiova, Romania;
| | - Marina Olimpia Amărăscu
- Department of Dental Morphology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Adrian Marcel Popescu
- Department of Prosthetic Dentistry, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (A.M.P.); (V.M.)
| | - Veronica Mercuţ
- Department of Prosthetic Dentistry, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (A.M.P.); (V.M.)
| | - Sanda Mihaela Popescu
- Department of Oral Rehabilitation, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania (S.M.P.)
| |
Collapse
|
15
|
Hussain U, Campobasso A, Noman M, Alam S, Mujeeb R, Shehzad S, Papageorgiou SN. Influence of elastomeric and steel ligatures on periodontal health during fixed appliance orthodontic treatment: a systematic review and meta-analysis. Prog Orthod 2024; 25:24. [PMID: 38880839 PMCID: PMC11180646 DOI: 10.1186/s40510-024-00520-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 04/20/2024] [Indexed: 06/18/2024] Open
Abstract
INTRODUCTION Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health. AIM This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances. METHODS Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach. RESULTS A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias. CONCLUSIONS Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load. REGISTRATION PROSPERO (CRD42023444383).
Collapse
Affiliation(s)
| | - Alessandra Campobasso
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | | | - Shamsul Alam
- Health Department Khyber Pakhtunkhwa, Peshawar, Pakistan
| | | | - Sofia Shehzad
- Community Dentistry, Sardar Begum Dental College, Gandhara University, Peshawar, Pakistan
| | - Spyridon N Papageorgiou
- Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland.
| |
Collapse
|
16
|
Fonseca D, de Tapia B, Pons R, Aparicio C, Guerra F, Messias A, Gil J. The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2944. [PMID: 38930312 PMCID: PMC11206074 DOI: 10.3390/ma17122944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 06/04/2024] [Accepted: 06/13/2024] [Indexed: 06/28/2024]
Abstract
Implantoplasty is a technique increasingly used to remove the biofilm that causes peri-implantitis on dental implants. This technique of mechanization of the titanium surface makes it possible to eliminate bacterial colonies, but it can generate variations in the properties of the implant. These variations, especially those in fatigue resistance and electrochemical corrosion behavior, have not been studied much. In this work, fatigue tests were performed on 60 dental implants without implantoplasty, namely 30 in air and 30 in Hank's solution at 37 °C, and 60 with implatoplasty, namely 30 in air and 30 in Hank's solution at 37 °C, using triaxial tension-compression and torsion stresses simulating human chewing. Mechanical tests were performed with a Bionix servo-hydraulic testing machine and fracture surfaces were studied by scanning electron microcopyElectrochemical corrosion tests were performed on 20 dental implants to determine the corrosion potentials and corrosion intensity for control implants and implantoplasty implants. Studies of titanium ion release to the physiological medium were carried out for each type of dental implants by Inductively Coupled-Plasma Mass Spectrometry at different immersion times at 37 °C. The results show a loss of fatigue caused by the implantoplasty of 30%, observing that the nucleation points of the cracks are in the areas of high deformation in the areas of the implant neck where the mechanization produced in the treatment of the implantoplasty causes an exaltation of fatigue cracks. It has been observed that tests performed in Hank's solution reduce the fatigue life due to the incorporation of hydrogen in the titanium causing the formation of hydrides that embrittle the dental implant. Likewise, the implantoplasty causes a reduction of the corrosion resistance with some pitting on the machined surface. Ion release analyses are slightly higher in the implantoplasted samples but do not show statistically significant differences. It has been observed that the physiological environment reduces the fatigue life of the implants due to the penetration of hydrogen into the titanium forming titanium hydrides which embrittle the implant. These results should be taken into account by clinicians to determine the convenience of performing a treatment such as implantoplasty that reduces the mechanical behavior and increases the chemical degradation of the titanium dental implant.
Collapse
Affiliation(s)
- Darcio Fonseca
- Bioengineering Institute of Technology, Medicine and Health Sciences Faculty, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain;
| | - Beatriz de Tapia
- Department of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain; (B.d.T.); (R.P.); (C.A.)
| | - Ramon Pons
- Department of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain; (B.d.T.); (R.P.); (C.A.)
| | - Conrado Aparicio
- Department of Periodontology, Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s/n, 08195 Sant Cugat del Vallès, Barcelona, Spain; (B.d.T.); (R.P.); (C.A.)
| | - Fernando Guerra
- Department Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Palácio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal; (F.G.); (A.M.)
| | - Ana Messias
- Department Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Palácio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal; (F.G.); (A.M.)
| | - Javier Gil
- Department Medicina Dentaire, Facultade de Medicina, Universidade de Coimbra, Palácio dos Grilos, Rua da Ilha, 3000-214 Coimbra, Portugal; (F.G.); (A.M.)
| |
Collapse
|
17
|
Kruse AB, Burkhardt AS, Vach K, Hellwig E, Woelber JP, Schlueter N, Ratka-Krüger P. Impact of air-polishing with erythritol on exposed root dentin: A randomized clinical trial. Int J Dent Hyg 2024. [PMID: 38852146 DOI: 10.1111/idh.12835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/08/2024] [Accepted: 05/11/2024] [Indexed: 06/11/2024]
Abstract
INTRODUCTION The effects of air-polishing on exposed root dentin surfaces are largely unknown, as there are only few studies which show heterogeneous results. Thus, this study was to investigate roughness changes of exposed dentin surfaces after air-polishing and the influence of subsequent polishing with cup and paste. METHODS Totally 54 teeth with exposed root dentin surfaces were treated using a split-mouth design by either air-polishing with erythritol and a rubber cup with polishing paste on the test side, or rubber cup and paste alone. Teeth were finally cleaned using a sonic tooth brush. Impressions were taken at relevant time points and replicated using epoxy resin. The resulting casts were profilometrically analysed to obtain the average surface roughness (sRa) and maximum peak-to-valley height (sRz), which are given as the mean ± standard deviation in μm. RESULTS After air-polishing, in comparison to the baseline, there was a slight but significant increase in sRa (0.168 ± 0.143, p < 0.001), but sRz did not change (-0.471 ± 4.857, p = 0.936). Subsequent polishing with cup and paste and cleaning with a sonic toothbrush did not reduce the surface roughness (sonic toothbrush-air-polishing, sRa -0.044 ± 0.081, p = 0.218; sRz -0.551 ± 3.563, p = 0.903). CONCLUSION The use of erythritol led to a slight increase in the roughness of the dentin surface, which was not reduced by polishing with a cup and paste. Polishing paste did not seem to conceal surface irregularities.
Collapse
Affiliation(s)
- Anne Brigitte Kruse
- Department of Operative Dentistry and Periodontology, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ann-Sophie Burkhardt
- Department of Operative Dentistry and Periodontology, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Kirstin Vach
- Department of Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Elmar Hellwig
- Department of Operative Dentistry and Periodontology, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Johan Peter Woelber
- Policlinic of Operative Dentistry, Periodontology, and Pediatric Dentistry, Medical Faculty Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Nadine Schlueter
- Department of Conservative Dentistry, Hannover Medical School, Periodontology and Preventive Dentistry, Hannover, Germany
| | - Petra Ratka-Krüger
- Department of Operative Dentistry and Periodontology, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
18
|
Alanazi KK, Wood D, Shepherd J, Stokes CW, Asencio IO. Assessing the suitability of fused deposition modeling to produce acrylic removable denture bases. Clin Exp Dent Res 2024; 10:e880. [PMID: 38798134 PMCID: PMC11128773 DOI: 10.1002/cre2.880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Revised: 02/21/2024] [Accepted: 03/03/2024] [Indexed: 05/29/2024] Open
Abstract
OBJECTIVE To study the feasibility of using poly methyl methacrylate (PMMA) filament and fused deposition modeling (FDM) to manufacture denture bases via the development of a study that considers both conventional and additive-based manufacturing techniques. MATERIALS AND METHODS Five sample groups were compared: heat and cold cured acrylic resins, CAD/CAM milled PMMA, 3D-printed PMMA (via FDM), and 3D-printed methacrylate resin (via stereolithography, SLA). All groups were subjected to mechanical testing (flexural strength, impact strength, and hardness), water sorption and solubility tests, a tooth bonding test, microbiological assessment, and accuracy of fit measurements. The performance of sample groups was referred to ISO 20795-1 and ISO/TS 19736. The data was analyzed using one-way ANOVA. RESULTS Samples manufactured using FDM performed within ISO specifications for mechanical testing, water sorption, and solubility tests. However, the FDM group failed to achieve the ISO requirements for the tooth bonding test. FDM samples presented a rough surface finish which could ultimately encourage an undesirable high level of microbial adhesion. For accuracy of fit, FDM samples showed a lower degree of accuracy than existing materials. CONCLUSIONS Although FDM samples were a cost-effective option and were able to be quickly manufactured in a reproducible manner, the results demonstrated that current recommended testing regimes for conventionally manufactured denture-based polymers are not directly applicable to additive-manufactured denture base polymers. Therefore, new standards should be developed to ensure the correct implementation of additive manufacturing techniques within denture-based fabrication workflow.
Collapse
Affiliation(s)
- Khalid K. Alanazi
- School of Clinical DentistryUniversity of SheffieldSheffieldUK
- Conservative Dental Science Department, College of DentistryPrince Sattam Bin Abdulaziz UniversitySaudi Arabia
| | - Duncan Wood
- School of Clinical DentistryUniversity of SheffieldSheffieldUK
| | - Joanna Shepherd
- School of Clinical DentistryUniversity of SheffieldSheffieldUK
| | | | | |
Collapse
|
19
|
Cesaria M, Calcagnile M, Arima V, Bianco M, Alifano P, Cataldo R. Cyclic olefin copolymer (COC) as a promising biomaterial for affecting bacterial colonization: investigation on Vibrio campbellii. Int J Biol Macromol 2024; 271:132550. [PMID: 38782326 DOI: 10.1016/j.ijbiomac.2024.132550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Revised: 03/22/2024] [Accepted: 05/20/2024] [Indexed: 05/25/2024]
Abstract
Cyclic olefin copolymer (COC) has emerged as an interesting biocompatible material for Organ-on-a-Chip (OoC) devices monitoring growth, viability, and metabolism of cells. Despite ISO 10993 approval, systematic investigation of bacteria grown onto COC is a still not documented issue. This study discusses biofilm formations of the canonical wild type BB120 Vibrio campbellii strain on a native COC substrate and addresses the impact of the physico-chemical properties of COC compared to conventional hydroxyapatite (HA) and poly(dimethylsiloxane) (PDMS) surfaces. An interdisciplinary approach combining bacterial colony counting, light microscopy imaging and advanced digital image processing remarks interesting results. First, COC can reduce biomass adhesion with respect to common biopolymers, that is suitable for tuning biofilm formations in the biological and medical areas. Second, remarkably different biofilm morphology (dendritic complex patterns only in the case of COC) was observed among the examined substrates. Third, the observed biofilm morphogenesis was related to the interaction of COC with the conditioning layer of the planktonic biological medium. Fourth, Level Co-occurrence Matrix (CGLM)-based analysis enabled quantitative assessment of the biomass textural fractal development under different coverage conditions. All of this is of key practical relevance in searching innovative biocompatible materials for pharmaceutical, implantable and medical products.
Collapse
Affiliation(s)
- Maura Cesaria
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Campus Ecotekne, Via per Arnesano, 73100 Lecce, Italy.
| | - Matteo Calcagnile
- Department of Biological and Environmental Sciences and Technologies (Di.S.Te.BA.), University of Salento, c/o Campus Ecotekne-S.P. 6, 73100 Lecce, Italy
| | - Valentina Arima
- CNR NANOTEC - Institute of Nanotechnology, c/o Campus Ecotekne, Lecce, Italy
| | - Monica Bianco
- CNR NANOTEC - Institute of Nanotechnology, c/o Campus Ecotekne, Lecce, Italy
| | - Pietro Alifano
- Department of Biological and Environmental Sciences and Technologies (Di.S.Te.BA.), University of Salento, c/o Campus Ecotekne-S.P. 6, 73100 Lecce, Italy
| | - Rosella Cataldo
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Campus Ecotekne, Via per Arnesano, 73100 Lecce, Italy
| |
Collapse
|
20
|
van Vliet K, van Splunter A, de Lange J, Lobbezoo F, Brand H. Protein Deposition on Sport Mouthguards and the Effectiveness of Two Different Cleaning Protocols. J Clin Med 2024; 13:3023. [PMID: 38892734 PMCID: PMC11172541 DOI: 10.3390/jcm13113023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 05/18/2024] [Accepted: 05/20/2024] [Indexed: 06/21/2024] Open
Abstract
Objective: To determine which salivary proteins adhere onto sport mouthguards, and to evaluate the effectiveness of different cleaning strategies in removing deposited protein. Methods: Fifteen healthy volunteers used a mouthguard for 1 h. The deposited salivary proteins were analyzed using gel electrophoresis and Western blotting techniques and compared with the protein composition of unstimulated saliva. In addition, the effectiveness of two different cleaning strategies to remove proteins from the mouthguards were compared: rinsing the mouthguards after use with cold tap water and cleaning the mouthguard with a soluble effervescent tablet. Results: Gel electrophoresis showed deposition of proteins of 50-60 kDa and 14 kDa on the mouthguards used in the mouth for 1 h. Western blotting identified these bands as amylase and lysozyme, respectively. Rinsing the mouthguard with cold tap water after use removed 91% of the total amount of deposited proteins, while cleaning with an effervescent tablet removed 99%. Conclusions: During the use of mouthguards, salivary proteins are deposited on their surface. Because salivary proteins can potentially affect bacterial adhesion to mouthguards, proper cleaning after use is recommended. Cleaning the mouthguard with cold tap water or using an effervescent tablet both seem to be effective strategies to remove proteins deposited on sport mouthguards.
Collapse
Affiliation(s)
- Kirsten van Vliet
- Academic Centre for Dentistry (ACTA)—Academic Medical Center Amsterdam (UMC), Department of Oral and Maxillofacial Surgery, 1081 HV Amsterdam, The Netherlands
| | - Annina van Splunter
- Academic Centre for Dentistry (ACTA), Department of Oral Biochemistry, 1081 LA Amsterdam, The Netherlands
| | - Jan de Lange
- Academic Centre for Dentistry (ACTA)—Academic Medical Center Amsterdam (UMC), Department of Oral and Maxillofacial Surgery, 1081 HV Amsterdam, The Netherlands
| | - Frank Lobbezoo
- Academic Centre for Dentistry (ACTA), Department of Orofacial Pain and Dysfunction, 1081 LA Amsterdam, The Netherlands
| | - Henk Brand
- Academic Centre for Dentistry (ACTA), Department of Oral Biochemistry, 1081 LA Amsterdam, The Netherlands
| |
Collapse
|
21
|
Goulart TS, Hawerroth T, da Silveira Teixeira C, Cesca K, Silva RR, de Moraes RR, Minamisako MC, Umeda Takashima MT, Cábia NC, Bortoluzzi EA, Mazzon RR, de Almeida J, da Fonseca Roberti Garcia L. Assessment of multispecies biofilm growth on root canal dentin under different radiation therapy regimens. Clin Oral Investig 2024; 28:324. [PMID: 38761225 DOI: 10.1007/s00784-024-05719-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 05/08/2024] [Indexed: 05/20/2024]
Abstract
OBJECTIVES To assess the growth of a multispecies biofilm on root canal dentin under different radiotherapy regimens. MATERIALS AND METHODS Sixty-three human root dentin cylinders were distributed into six groups. In three groups, no biofilm was formed (n = 3): NoRT) non-irradiated dentin; RT55) 55 Gy; and RT70) 70 Gy. In the other three groups (n = 18), a 21-day multispecies biofilm (Enterococcus faecalis, Streptococcus mutans, and Candida albicans) was formed in the canal: NoRT + Bio) non-irradiated + biofilm; RT55 + Bio) 55 Gy + biofilm; and RT70 + Bio) 70 Gy + biofilm. The biofilm was quantified (CFUs/mL). Biofilm microstructure was assessed under SEM. Microbial penetration into dentinal tubules was assessed under CLSM. For the biofilm biomass and dentin microhardness pre- and after biofilm growth assessments, 45 bovine dentin specimens were distributed into three groups (n = 15): NoRT) non-irradiated + biofilm; RT55 + Bio) 55 Gy + biofilm; and RT70 + Bio) 70 Gy + biofilm. RESULTS Irradiated specimens (70 Gy) had higher quantity of microorganisms than non-irradiated (p = .010). There was gradual increase in biofilm biomass from non-irradiated to 55 Gy and 70 Gy (p < .001). Irradiated specimens had greater reduction in microhardness after biofilm growth. Irradiated dentin led to the growth of a more complex and irregular biofilm. There was microbial penetration into the dentinal tubules, regardless of the radiation regimen. CONCLUSION Radiotherapy increased the number of microorganisms and biofilm biomass and reduced dentin microhardness. Microbial penetration into dentinal tubules was noticeable. CLINICAL RELEVANCE Cumulative and potentially irreversible side effects of radiotherapy affect biofilm growth on root dentin. These changes could compromise the success of endodontic treatment in oncological patients undergoing head and neck radiotherapy.
Collapse
Affiliation(s)
- Taynara Santos Goulart
- Department of Dentistry - Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus Reitor João David Ferreira Lima, Florianópolis, CEP: 88040-900, Santa Catarina, Brazil
| | - Tainara Hawerroth
- Department of Endodontics, University of Southern Santa Catarina, Palhoça, Santa Catarina, Brazil
| | - Cleonice da Silveira Teixeira
- Department of Dentistry - Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus Reitor João David Ferreira Lima, Florianópolis, CEP: 88040-900, Santa Catarina, Brazil
| | - Karina Cesca
- Department of Chemical Engineering, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Rodrigo Rohenkohl Silva
- Department of Restorative Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| | - Rafael Ratto de Moraes
- Department of Restorative Dentistry, Federal University of Pelotas, Pelotas, Rio Grande do Sul, Brazil
| | | | | | - Nayara Cardoso Cábia
- Department of Radiotherapy, Oncology Research Center (CEPON), Florianópolis, SC, Brazil
| | - Eduardo Antunes Bortoluzzi
- Department of Diagnosis & Oral Health, Endodontics Division, University of Louisville, Louisville, KY, USA
| | - Ricardo Ruiz Mazzon
- Department of Microbiology, Immunology and Parasitology, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Josiane de Almeida
- Department of Endodontics, University of Southern Santa Catarina, Palhoça, Santa Catarina, Brazil
| | - Lucas da Fonseca Roberti Garcia
- Department of Dentistry - Endodontics Division, Health Sciences Center, Federal University of Santa Catarina, Campus Reitor João David Ferreira Lima, Florianópolis, CEP: 88040-900, Santa Catarina, Brazil.
| |
Collapse
|
22
|
Vulović S, Todorović A, Toljić B, Nikolić-Jakoba N, Tovilović TV, Milić-Lemić A. Evaluation of early bacterial adhesion on CAD/CAM dental materials: an in situ study. Odontology 2024:10.1007/s10266-024-00944-y. [PMID: 38705962 DOI: 10.1007/s10266-024-00944-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Accepted: 04/24/2024] [Indexed: 05/07/2024]
Abstract
The aim of this research was to determine if there are differences in early bacterial adhesion among CAD/CAM dental materials after 24 h exposure in the oral environment. One hundred twenty specimens were prepared according to the manufacturer's recommendations and divided into six groups: RBC (resin-based composite), PMMA (polymethyl methacrylate), PEEK (polyether ether ketone), ZP (zirconia polished), ZG (zirconia glazed), and cobalt-chromium alloy (CoCr alloy). Twenty healthy participants were instructed to carry an intraoral device with six specimens, one per group, for 24 h. Thereafter, real-time polymerase chain reaction (qPCR) and scanning electron microscopy (SEM) analyses enabled quantification and 2D view of biofilm formed on the specimens' surfaces. Kruskal-Wallis test and Dunn's post hoc analysis were used for inter-group comparison and data were presented as median (minimum-maximum). RBC specimens accumulated less bacteria, in comparison with ZG (p = 0.017) and PEEK specimens (p = 0.030), that dominated with the highest amount of adhered bacterial biofilm. PMMA, CoCr, and ZP specimens adhered more bacteria than RBC (p > 0.05), and less than ZG (p > 0.05) and PEEK (p > 0.05). The bacterial number varied considerably among participants. The obtained results enable a closer view into the susceptibility of CAD/CAM materials to microorganisms during the presence in the oral environment, which can be beneficial for a proper selection of these materials for a variety of dental restorations.
Collapse
Affiliation(s)
- Stefan Vulović
- Department of Prosthodontics, School of Dental Medicine, University of Belgrade, Belgrade, Serbia.
| | - Aleksandar Todorović
- Department of Prosthodontics, School of Dental Medicine, University of Belgrade, Belgrade, Serbia
| | - Boško Toljić
- Department of Human Genetics, School of Dental Medicine, University of Belgrade, Belgrade, Serbia
| | - Nataša Nikolić-Jakoba
- Department of Periodontology and Oral Medicine, School of Dental Medicine, University of Belgrade, Belgrade, Serbia
| | - Tamara Vlajić Tovilović
- Department of Microbiology and Immunology, School of Dental Medicine, University of Belgrade, Belgrade, Serbia
| | - Aleksandra Milić-Lemić
- Department of Prosthodontics, School of Dental Medicine, University of Belgrade, Belgrade, Serbia
| |
Collapse
|
23
|
Verma M, Pathak AK, Verma UP, Patil RK, Yadav L, Tiwari AK. Comparison of bone loss around submerged and non-submerged implants during osseointegration phase. Natl J Maxillofac Surg 2024; 15:252-261. [PMID: 39234133 PMCID: PMC11371283 DOI: 10.4103/njms.njms_116_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 08/25/2022] [Accepted: 12/14/2022] [Indexed: 09/06/2024] Open
Abstract
Background In Modern dentistry, the implant is the most popular and desirable management of tooth loss. Traditionally two stage (submerged) or one-stage (non-submerged) system has been added by many investigators. In the present study we evaluated the crestal bone loss during osseointegration phase among the three groups (i.e. submerged implants, non-submerged implants with anatomical healing abutment and non- submerged implants with esthetic healing abutment). Material and Methods 10 subjects with 30 implants, were enrolled in the study. Subjects were randomized in three groups i.e., group 1 submerged (n=10), group 2 non-submerged with anatomical healing abutment (n=10), group 3 non submerged with esthetic healing abutments (n=10). Intraoral periapical radiograph (IOPA), IMAGE J software and CBCT were used to evaluate the crestal bone loss around each implant at baseline, 1 and 3 months after implant placement. Results Crestal bone loss at the end of the 3months (osseointegration phase) was lowest in the submerged group (0.18+-0.06mm) followed by non-submerged esthetic group (0.21+-0.03mm) but it was statistically insignificant. Maximum amount of bone loss was observed in non-submerged anatomical abutment group (0.34+-0.03mm) which was highly significant. Conclusion It can be concluded that submerged implants technique is a better option in comparison to non-submerged implant technique in terms of radiographical performance during initial phases of osseointegration.
Collapse
Affiliation(s)
- Manisha Verma
- Department of Periodontology, Faculty of Dental Sciences, King George’s Medical University, Lucknow, Uttar Pradesh, India
| | - Anjani K. Pathak
- Department of Periodontology, Faculty of Dental Sciences, King George’s Medical University, Lucknow, Uttar Pradesh, India
| | - Umesh P. Verma
- Department of Periodontology, Faculty of Dental Sciences, King George’s Medical University, Lucknow, Uttar Pradesh, India
| | - Ranjit K. Patil
- Department of Oral Medicine and Radiology, Faculty of Dental Sciences, King George’s Medical University, Lucknow, Uttar Pradesh, India
| | - Lakshya Yadav
- Department of Prosthodontics Crown and Bridge, Faculty of Dental Sciences, King George’s Medical University, Lucknow, Uttar Pradesh, India
| | - Arunesh K. Tiwari
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Sciences, King George’s Medical University, Lucknow, Uttar Pradesh, India
| |
Collapse
|
24
|
Topçu S, Tekçe N, Kopuz D, Özcelik EY, Kolaylı F, Tuncer S, Demirci M. Effect of surface roughness and biofilm formation on the color properties of resin-infiltrated ceramic and lithium disilicate glass-ceramic CAD-CAM materials. J Prosthet Dent 2024; 131:935.e1-935.e8. [PMID: 38431509 DOI: 10.1016/j.prosdent.2024.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 02/06/2024] [Accepted: 02/09/2024] [Indexed: 03/05/2024]
Abstract
STATEMENT OF PROBLEM Computer-aided design and computer-aided manufacturing (CAD-CAM) materials have become popular for dental restorations; however, which materials should be preferred in terms of surface properties after biofilm formation is unclear. PURPOSE The purpose of this in vitro study was to investigate the effect of biofilm formation on the discoloration properties of resin-infiltrated ceramic and glass-ceramic CAD-CAM materials and human teeth and to examine the effect of the brushing procedure on color change. MATERIAL AND METHODS One hundred and six 2-mm-thick specimens were prepared from IPS e.max CAD and Cerasmart, and a total of 53 intact human teeth were used. Five specimens from each group were used to measure the amount of live biomass in the biofilm. The remaining 48 specimens in each group were divided into 4 subgroups: kept in distilled water without the formation of dental biofilm (DW), kept in tea without the formation of dental biofilm (T), kept in distilled water after the formation of dental biofilm (DWB), and kept in tea after the formation of dental biofilm (TB) (n=12). After finishing and polishing the materials, initial color measurements were made using a spectrophotometer, and surface roughness measurements were made using noncontact profilometer. After creating a biofilm layer in DWB and TB, all specimens were kept in their solutions at 37 °C for 24 hours, and the color measurements were repeated. After the biofilm layer had been removed by brushing, a third color measurement was made. The data were statistically analyzed with one-way analysis of variance (ANOVA) and two-way ANOVA (α=.05). RESULTS The lowest roughness value was observed in Cerasmart. Tooth-IPS e.max CAD gave similar results. The Cerasmart material had the most viable biomass, whereas the IPS e.max CAD material had the least. TB had the highest ΔE1 value for all materials and DW had the lowest (P<.05). The brushing procedure caused the materials to return to their initial colors or reduce the color change in most groups. CONCLUSIONS The presence of biofilm on CAD-CAM materials immersed in distilled water caused an unacceptable degree of discoloration (ΔE>1.8), and immersion in tea led to greater color change. The adhesion of biofilm to restorative dental materials plays an important role in the coloring of these dental materials.
Collapse
Affiliation(s)
- Sümeyra Topçu
- Research Assistant, Department of Restorative Dentistry, Kocaeli University, Kocaeli, Turkey
| | - Neslihan Tekçe
- Professor, Department of Restorative Dentistry, Kocaeli University, Kocaeli, Turkey
| | - Dilan Kopuz
- Assistant Professor, Department of Restorative Dentistry, Istanbul Kent University, Istanbul, Turkey.
| | - Eda Yazıcı Özcelik
- Research Assistant, Department of Microbiology and Clinical Microbiology, Kocaeli University, Kocaeli, Turkey
| | - Fetiye Kolaylı
- Professor, Department of Microbiology and Clinical Microbiology, Kocaeli University, Kocaeli, Turkey
| | - Safa Tuncer
- Professor, Department of Restorative Dentistry, Istanbul University, Istanbul, Turkey
| | - Mustafa Demirci
- Professor, Department of Restorative Dentistry, Istanbul University, Istanbul, Turkey
| |
Collapse
|
25
|
Schubert A, Griesmüller C, Gersdorff N, Bürgers R, Wiechens B, Wassmann T. Antibacterial coating of orthodontic elastomeric ligatures with silver and bismuth nanofilms by magnetron sputtering: A feasibility study. Clin Exp Dent Res 2024; 10:e864. [PMID: 38433291 PMCID: PMC10909824 DOI: 10.1002/cre2.864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 01/11/2024] [Accepted: 01/20/2024] [Indexed: 03/05/2024] Open
Abstract
OBJECTIVES Magnetron sputtering was evaluated to equip surfaces of orthodontic elastomeric ligatures with silver and bismuth nanofilms. MATERIAL AND METHODS Antibacterial properties were evaluated by the adhesion of Streptococcus mutans. Polyurethane-based elastomeric ligatures were coated with silver and bismuth nanofilms via direct current magnetron sputtering. Surface roughness (Ra ) and surface-free energy (SFE) were assessed. Coated specimens were incubated with S. mutans for 2 h. Adhering bacteria were visualized by Hoechst staining and quantified by an ATP-based luminescence assay. One-way analysis of variance with Tukey post hoc testing and Pearson correlation analysis were performed (p < .05) to relate bacterial adhesion to surface roughness and surface-free energy. RESULTS Elastomeric ligatures were successfully coated with silver and bismuth nanofilms. Ra was significantly reduced by silver coating. Silver and bismuth coatings showed significantly higher SFE than controls. Adhesion of S. mutans was significantly decreased by silver coating. No correlation between bacterial adhesion and SFE was found. Correlation between bacterial adhesion and Ra was positive but not statistically significant. CONCLUSIONS Magnetron sputtering proved to be a feasible method to equip orthodontic elastomeric ligatures with silver and bismuth nanofilms. Silver coatings of elastomeric ligatures may reduce white spots and carious lesions in orthodontic patients. Future research is required to stabilize coatings.
Collapse
Affiliation(s)
- Andrea Schubert
- Department of ProsthodonticsUniversity Medical Center GoettingenGoettingenGermany
| | - Carolin Griesmüller
- Department of ProsthodonticsUniversity Medical Center GoettingenGoettingenGermany
| | - Nikolaus Gersdorff
- Department of ProsthodonticsUniversity Medical Center GoettingenGoettingenGermany
| | - Ralf Bürgers
- Department of ProsthodonticsUniversity Medical Center GoettingenGoettingenGermany
| | - Bernhard Wiechens
- Department of OrthodonticsUniversity Medical Center GoettingenGoettingenGermany
| | - Torsten Wassmann
- Department of ProsthodonticsUniversity Medical Center GoettingenGoettingenGermany
| |
Collapse
|
26
|
Tzimas K, Rahiotis C, Pappa E. Biofilm Formation on Hybrid, Resin-Based CAD/CAM Materials for Indirect Restorations: A Comprehensive Review. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1474. [PMID: 38611989 PMCID: PMC11012497 DOI: 10.3390/ma17071474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 03/14/2024] [Accepted: 03/21/2024] [Indexed: 04/14/2024]
Abstract
Hybrid materials are a recent addition in the field of restorative dentistry for computer-aided design/computer-aided manufacturing (CAD/CAM) indirect restorations. The long-term clinical success of modern dental restorative materials is influenced by multiple factors. Among the characteristics affecting the longevity of a restoration, the mechanical properties and physicοchemical interactions are of utmost importance. While numerous researchers constantly evaluate mechanical properties, the biological background of resin-based CAD/CAM biomaterials is scarcely investigated and, therefore, less described in the literature. This review aims to analyze biofilm formation on the surfaces of novel, hybrid, resin-based CAD/CAM materials and evaluate the methodological protocols followed to assess microbial growth. It is demonstrated that the surface structure, the composition and the finishing and polishing procedures on the surface of a dental restorative material influence initial bacterial adhesion; however, most studies focus on in vitro protocols, and in vivo and/or in situ research of microbiomics in CAD/CAM restorative materials is lacking, obstructing an accurate understanding of the bioadhesion phenomenon in the oral cavity.
Collapse
Affiliation(s)
| | - Christos Rahiotis
- Department of Operative Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece; (K.T.); (E.P.)
| | | |
Collapse
|
27
|
Areid N, Abushahba F, Riivari S, Närhi T. Effect of TiO 2 Abutment Coatings on Peri-Implant Soft Tissue Behavior: A Systematic Review of In Vivo Studies. Int J Dent 2024; 2024:9079673. [PMID: 38533472 PMCID: PMC10965279 DOI: 10.1155/2024/9079673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/21/2024] [Accepted: 03/05/2024] [Indexed: 03/28/2024] Open
Abstract
Establishing a proper soft tissue adhesion around the implant abutment is essential to prevent microbial invasion, inhibit epithelial downgrowth, and obtain an optimal healing process. This systematic review aims to evaluate the real potential of TiO2 coating on the behavior of peri-implant soft tissue health and maintenance. A specific aim was to evaluate clinically and histologically the effect of TiO2 abutment coating on epithelial and connective tissue attachment. Electronic database searches were conducted from 1990 to 2023 in MEDLINE/PubMed and the Web of Science databases. In total, 15 out of 485 publications were included. Eight studies involved humans, and seven were animal studies. Exposure time ranges from 2 days to 5 years. The peri-implant soft tissue evaluations included clinical assessment (plaque index (PI), peri-implant probing pocket depth (PPD), and bleeding on probing (BoP)), histological as well as histomorphometric analysis. The Office of Health Assessment and Translation (OHAT) Risk of Bias Rating Tool for Human and Animal Studies was used to evaluate the overall quality of the studies included in the review. The results showed some variation but remained within acceptable limits. Within the limitations of this systematic review, the present findings suggest that TiO2 coatings seem to influence soft tissue healing. TiO2-coated abutments with a roughness value between 0.2 and 0.5 μm enhance soft tissue health. Sol-gel-derived TiO2 coatings induced better soft tissue attachment than noncoated machined abutment surfaces. The anodized titanium abutments demonstrate comparable clinical and histological outcomes to conventional machined abutments. However, there was variation among the included studies concerning TiO2 coating characteristics and the measured outcomes used to evaluate the soft tissue response, and therefore, quantitative analysis was not feasible. Long-term in vivo studies with standardized soft tissue analysis and coating surface parameters are necessary before a definitive conclusion can be drawn. OSF Registration No.: 10.17605/OSF.IO/E5RQV.
Collapse
Affiliation(s)
- Nagat Areid
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku FI-20520, Finland
| | - Faleh Abushahba
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku FI-20520, Finland
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC, Institute of Dentistry, University of Turku, Turku FI-20520, Finland
- Department of Restorative Dentistry and Periodontology, Faculty of Dentistry, Libyan International Medical University (LIMU), Benghazi 339P+62Q, Libya
| | - Sini Riivari
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku FI-20520, Finland
| | - Timo Närhi
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku FI-20520, Finland
- Wellbeing Services County of South-West Finland, Turku FI-20521, Finland
| |
Collapse
|
28
|
Schwartz-Filho HO, Martins TR, Sano PR, Araújo MT, Chan DCH, Saldanha NR, Silva KDP, Graziano TS, Brandt WC, Torres CVR, Cogo-Müller K. Nanotopography and oral bacterial adhesion on titanium surfaces: in vitro and in vivo studies. Braz Oral Res 2024; 38:e021. [PMID: 38477807 PMCID: PMC11376621 DOI: 10.1590/1807-3107bor-2024.vol38.0021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 10/03/2023] [Indexed: 03/14/2024] Open
Abstract
The present study aimed to evaluate the influence of titanium surface nanotopography on the initial bacterial adhesion process by in vivo and in vitro study models. Titanium disks were produced and characterized according to their surface topography: machined (Ti-M), microtopography (Ti-Micro), and nanotopography (Ti-Nano). For the in vivo study, 18 subjects wore oral acrylic splints containing 2 disks from each group for 24 h (n = 36). After this period, the disks were removed from the splints and evaluated by microbial culture method, scanning electron microscopy (SEM), and qPCR for quantification of Streptococcus oralis, Actinomyces naeslundii, Fusobacterium nucleatum, as well as total bacteria. For the in vitro study, adhesion tests were performed with the species S. oralis and A. naeslundii for 24 h. Data were compared by ANOVA, with Tukey's post-test. Regarding the in vivo study, both the total aerobic and total anaerobic bacteria counts were similar among groups (p > 0.05). In qPCR, there was no difference among groups of bacteria adhered to the disks (p > 0.05), except for A. naeslundii, which was found in lower proportions in the Ti-Nano group (p < 0.05). In the SEM analysis, the groups had a similar bacterial distribution, with a predominance of cocci and few bacilli. In the in vitro study, there was no difference in the adhesion profile for S. oralis and A. naeslundii after 24 h of biofilm formation (p > 0.05). Thus, we conclude that micro- and nanotopography do not affect bacterial adhesion, considering an initial period of biofilm formation.
Collapse
Affiliation(s)
| | | | - Paulo Roberto Sano
- Universidade de Santo Amaro - Unisa, Department of Dentistry, São Paulo, SP, Brazil
| | - Marcela Takemoto Araújo
- Universidade Estadual de Campinas - Unicamp, Piracicaba Dental School, Department of Physiological Sciences, Piracicaba, SP, Brazil
| | - Daniel Cheuk Hong Chan
- Universidade Estadual de Campinas - Unicamp, Piracicaba Dental School, Department of Physiological Sciences, Piracicaba, SP, Brazil
| | | | - Kátia de Pádua Silva
- Universidade Estadual de Campinas - Unicamp, School of Pharmaceutical Sciences, Laboratory of Antimicrobial Pharmacology and Microbiology, Campinas, SP, Brazil
| | - Talita Signoreti Graziano
- Universidade Estadual de Campinas - Unicamp, Piracicaba Dental School, Department of Physiological Sciences, Piracicaba, SP, Brazil
| | - William Cunha Brandt
- Universidade de Santo Amaro - Unisa, Department of Dentistry, São Paulo, SP, Brazil
| | | | - Karina Cogo-Müller
- Universidade Estadual de Campinas - Unicamp, School of Pharmaceutical Sciences, Laboratory of Antimicrobial Pharmacology and Microbiology, Campinas, SP, Brazil
| |
Collapse
|
29
|
Kadirvelu L, Sivaramalingam SS, Jothivel D, Chithiraiselvan DD, Karaiyagowder Govindarajan D, Kandaswamy K. A review on antimicrobial strategies in mitigating biofilm-associated infections on medical implants. CURRENT RESEARCH IN MICROBIAL SCIENCES 2024; 6:100231. [PMID: 38510214 PMCID: PMC10951465 DOI: 10.1016/j.crmicr.2024.100231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/22/2024] Open
Abstract
Biomedical implants are crucial in providing support and functionality to patients with missing or defective body parts. However, implants carry an inherent risk of bacterial infections that are biofilm-associated and lead to significant complications. These infections often result in implant failure, requiring replacement by surgical restoration. Given these complications, it is crucial to study the biofilm formation mechanism on various biomedical implants that will help prevent implant failures. Therefore, this comprehensive review explores various types of implants (e.g., dental implant, orthopedic implant, tracheal stent, breast implant, central venous catheter, cochlear implant, urinary catheter, intraocular lens, and heart valve) and medical devices (hemodialyzer and pacemaker) in use. In addition, the mechanism of biofilm formation on those implants, and their pathogenesis were discussed. Furthermore, this article critically reviews various approaches in combating implant-associated infections, with a special emphasis on novel non-antibiotic alternatives to mitigate biofilm infections.
Collapse
Affiliation(s)
- Lohita Kadirvelu
- Research Center for Excellence in Microscopy, Department of Biotechnology, Kumaraguru College of Technology, Coimbatore, 641049, Tamil Nadu, India
| | - Sowmiya Sri Sivaramalingam
- Research Center for Excellence in Microscopy, Department of Biotechnology, Kumaraguru College of Technology, Coimbatore, 641049, Tamil Nadu, India
| | - Deepsikha Jothivel
- Research Center for Excellence in Microscopy, Department of Biotechnology, Kumaraguru College of Technology, Coimbatore, 641049, Tamil Nadu, India
| | - Dhivia Dharshika Chithiraiselvan
- Research Center for Excellence in Microscopy, Department of Biotechnology, Kumaraguru College of Technology, Coimbatore, 641049, Tamil Nadu, India
| | | | - Kumaravel Kandaswamy
- Research Center for Excellence in Microscopy, Department of Biotechnology, Kumaraguru College of Technology, Coimbatore, 641049, Tamil Nadu, India
| |
Collapse
|
30
|
Luo K, Liu Q, Alhotan A, Dai J, Li A, Xu S, Li P. Effect of post-curing conditions on surface characteristics, physico-mechanical properties, and cytotoxicity of a 3D-printed denture base polymer. Dent Mater 2024; 40:500-507. [PMID: 38184445 DOI: 10.1016/j.dental.2023.12.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/08/2024]
Abstract
OBJECTIVE This study aims to investigate the influence of post-polymerization (post-curing) conditions on surface characteristics, flexural properties, water sorption and solubility, and cytotoxicity of additively manufactured denture base materials. METHODS The tested specimens were additively manufactured using digital light processing and classified into different post-curing condition groups: submerged in water (WAT), submerged in glycerin (GLY), and air exposure (AIR). An uncured specimen (UNC) was used as a control. The surface topography and roughness were observed. The flexural strength and modulus were determined via a three-point bending test. The water sorption and solubility were subsequently tested. Finally, an extract test was performed to assess cytotoxicity. RESULTS Different post-curing conditions had no significant effects on the surface topography and roughness (Sa value). Various post-curing conditions also had no significant effects on the flexural strength. Notably, the flexural modulus of the WAT group (2671.80 ± 139.42 MPa) was significantly higher than the AIR group (2197.47 ± 197.93 MPa, p = 0.0103). After different post-curing conditions, the water sorption and solubility of the specimens met the ISO standards. Finally, all post-curing conditions effectively reduced cytotoxic effects. SIGNIFICANCES Post-curing with different oxygen levels improved flexural properties, and flexural modulus significantly increased after the specimens were submerged in water. In addition, water sorption and solubility, and cytocompatibility were optimized by post-curing, irrespective of the post-curing conditions. Therefore, the water-submerged conditions optimized the flexural modulus of the 3D-printed denture base materials.
Collapse
Affiliation(s)
- Ke Luo
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Qian Liu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Abdulaziz Alhotan
- Dental Health Department, College of Applied Medical Sciences, King Saud University, P.O.Box 10219, Riyadh 12372, Saudi Arabia
| | - Jingtao Dai
- Department of Orthodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - An Li
- Department of Periodontology, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China.
| | - Ping Li
- School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou, Guangdong 510182, China; Department of Prosthodontics, School and Hospital of Stomatology, Guangzhou Medical University, Guangzhou, Guangdong 510182, China.
| |
Collapse
|
31
|
Tagliaferri N, Pisciotta A, Orlandi G, Bertani G, Di Tinco R, Bertoni L, Sena P, Lunghi A, Bianchi M, Veneri F, Bellini P, Bertacchini J, Conserva E, Consolo U, Carnevale G. Zirconia Hybrid Dental Implants Influence the Biological Properties of Neural Crest-Derived Mesenchymal Stromal Cells. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:392. [PMID: 38470723 PMCID: PMC10934982 DOI: 10.3390/nano14050392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/14/2024] [Accepted: 02/16/2024] [Indexed: 03/14/2024]
Abstract
Dental implants are regularly employed in tooth replacement, the good clinical outcome of which is strictly correlated to the choice of an appropriate implant biomaterial. Titanium-based implants are considered the gold standard for rehabilitation of edentulous spaces. However, the insurgence of allergic reactions, cellular sensitization and low integration with dental and gingival tissues lead to poor osseointegration, affecting the implant stability in the bone and favoring infections and inflammatory processes in the peri-implant space. These failures pave the way to develop and improve new biocompatible implant materials. CERID dental implants are made of a titanium core embedded in a zirconium dioxide ceramic layer, ensuring absence of corrosion, a higher biological compatibility and a better bone deposition compared to titanium ones. We investigated hDPSCs' biological behavior, i.e., cell adhesion, proliferation, morphology and osteogenic potential, when seeded on both CERID and titanium implants, before and after cleansing with two different procedures. SEM and AFM analysis of the surfaces showed that while CERID disks were not significantly affected by the cleansing system, titanium ones exhibited well-visible modifications after brush treatment, altering cell morphology. The proliferation rate of DPSCs was increased for titanium, while it remained unaltered for CERID. Both materials hold an intrinsic potential to promote osteogenic commitment of neuro-ectomesenchymal stromal cells. Interestingly, the CERID surface mitigated the immune response by inducing an upregulation of anti-inflammatory cytokine IL-10 on activated PBMCs when a pro-inflammatory microenvironment was established. Our in vitro results pave the way to further investigations aiming to corroborate the potential of CERID implants as suitable biomaterials for dental implant applications.
Collapse
Affiliation(s)
- Nadia Tagliaferri
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
- PhD Program in Clinical and Experimental Medicine, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 41124 Modena, Italy
| | - Alessandra Pisciotta
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Giulia Orlandi
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Giulia Bertani
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
- PhD Program in Clinical and Experimental Medicine, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 41124 Modena, Italy
| | - Rosanna Di Tinco
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Laura Bertoni
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Paola Sena
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Alice Lunghi
- Center for Translational Neurophysiology of Speech and Communication, Fondazione Istituto Italiano di Tecnologia, 44121 Ferrara, Italy;
- Section of Physiology, University of Ferrara, 44121 Ferrara, Italy
| | - Michele Bianchi
- Department of Life Sciences, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Federica Veneri
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Pierantonio Bellini
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Jessika Bertacchini
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Enrico Conserva
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Ugo Consolo
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| | - Gianluca Carnevale
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Interest in Transplant, Oncology and Regenerative Medicine, University of Modena and Reggio Emilia, 41124 Modena, Italy; (N.T.); (G.O.); (G.B.); (R.D.T.); (L.B.); (P.S.); (F.V.); (P.B.); (J.B.); (E.C.); (U.C.); (G.C.)
| |
Collapse
|
32
|
Smirnov A, Yanushevich O, Krikheli N, Solis Pinargote NW, Peretyagin P, Grigoriev S, Alou L, Sevillano D, López-Piriz R, Guitian F, Bartolomé JF. 3Y-TZP/Ta Biocermet as a Dental Material: An Analysis of the In Vitro Adherence of Streptococcus Oralis Biofilm and an In Vivo Pilot Study in Dogs. Antibiotics (Basel) 2024; 13:175. [PMID: 38391561 PMCID: PMC10886202 DOI: 10.3390/antibiotics13020175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 02/24/2024] Open
Abstract
The surface adhesion of bacterial cells and the in vivo biocompatibility of a new ceramic-metal composite made of zirconium dioxide and tantalum were evaluated. Within the framework of an in vitro study using the crystal violet staining and colony counting methods, a relatively similar adhesion of Streptococcus oralis to the 3Y-TZP/Ta biocermet (roughness Ra = 0.12 ± 0.04 µm) and Ti-Al6-V4 titanium alloy (Ra = 0.04 ± 0.01 µm) was found. In addition, in an in vivo preliminary study focused on the histological analysis of a series of rods implanted in the jaws of beagle dogs for a six-month period, the absence of any fibrous tissue or inflammatory reaction at the interface between the implanted 3Y-TZP/Ta biocermets and the new bone was found. Thus, it can be concluded that the developed ceramic-metal biocomposite may be a promising new material for use in dentistry.
Collapse
Affiliation(s)
- Anton Smirnov
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
| | - Oleg Yanushevich
- Scientific Department, A.I. Evdokimov Moscow State University of Medicine and Dentistry, Delegatskaya St., 20, p. 1, Moscow 127473, Russia
| | - Natella Krikheli
- Scientific Department, A.I. Evdokimov Moscow State University of Medicine and Dentistry, Delegatskaya St., 20, p. 1, Moscow 127473, Russia
| | - Nestor Washington Solis Pinargote
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
| | - Pavel Peretyagin
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
- Scientific Department, A.I. Evdokimov Moscow State University of Medicine and Dentistry, Delegatskaya St., 20, p. 1, Moscow 127473, Russia
| | - Sergey Grigoriev
- Spark Plasma Sintering Research Laboratory, Moscow State University of Technology "STANKIN", Vadkovsky per. 1, Moscow 127055, Russia
| | - Luis Alou
- Microbiology Department, School of Medicine, Universidad Complutense, Avda. Complutense s/n, 28040 Madrid, Spain
| | - David Sevillano
- Microbiology Department, School of Medicine, Universidad Complutense, Avda. Complutense s/n, 28040 Madrid, Spain
| | - Roberto López-Piriz
- Instituto de Cirugía Oral Avanzada-ICOA, Calle de Fray Luis de León, 14, 28012 Madrid, Spain
| | - Francisco Guitian
- Instituto de Materiales, iMATUS-USC, Santiago de Compostela, Avenida do Mestre Mateo 25, 15782 La Coruña, Spain
| | - José Florindo Bartolomé
- Instituto de Ciencia de Materiales de Madrid (ICMM), Consejo Superior de Investigaciones Científicas (CSIC), Campus de Cantoblanco, Calle Sor Juana Inés de la Cruz 3, 28049 Madrid, Spain
| |
Collapse
|
33
|
Jiang C, Sun Y, Li G, Zhou T, Wang Q, Zhang J, Song Y, Xu W, A L. Magnetic Hydroxyapatite-Coated Iron-Chromium Microspheres for Dental Surface Polishing and Plaque Removal. ACS APPLIED MATERIALS & INTERFACES 2024; 16:5554-5567. [PMID: 38278767 DOI: 10.1021/acsami.3c16398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2024]
Abstract
This research aimed to engineer magnetic hydroxyapatite-coated iron-chromium (HAp-FeCr) microspheres to enhance dental surface polishing and plaque elimination. Utilizing a tailored sol-gel approach, the HAp-FeCr microspheres were synthesized and exhaustively characterized via scanning electron microscopy, energy-dispersive X-ray spectroscopy, ζ-potential, X-ray diffractometry, and X-ray photoelectron spectroscopy methodologies. Key findings showcased that these microspheres retained their magnetic properties post-HAp coating, as evidenced by the magnetization curves. An innovative magnetic polishing system was developed, incorporating these microspheres and a 2000 rpm magnet. Comparative evaluations between traditional air-powder polishing and the proposed magnetic technique demonstrated the latter's superiority. Notably, the magnetic polishing led to a substantial reduction in dental plaque on the tooth surface, decreasing bacterial adhesion and early biofilm formation by Streptococcus gordonii and Lactobacillus acidophilus, where the most pronounced effects were observed in samples with elevated HAp content. A significant 60% reduction in dental plaque was achieved with the magnetic method relative to air-powder polishing. Furthermore, the HAp-FeCr microspheres' biocompatibility was verified through cytotoxicity tests and animal studies. In essence, the magnetic HAp-FeCr microspheres present a novel and efficient strategy for dental treatments, holding immense potential for improving oral health.
Collapse
Affiliation(s)
- Cong Jiang
- Department of Oral Implantology, School and Hospital of Stomatology, Jilin University, Changchun 130021, China
| | - Yue Sun
- Department of Oral Implantology, School and Hospital of Stomatology, Jilin University, Changchun 130021, China
- Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering, Changchun 130021, China
| | - Gaojie Li
- Key Laboratory of Automobile Materials, Ministry of Education, College of Materials Science and Engineering, Jilin University, Changchun 130021, China
| | - Tianyu Zhou
- Department of Oral Implantology, School and Hospital of Stomatology, Jilin University, Changchun 130021, China
| | - Qiqi Wang
- Department of Periodontology, School and Hospital of Stomatology, Jilin University, Changchun 130021, China
| | - Jingdan Zhang
- Department of Periodontology, School and Hospital of Stomatology, Jilin University, Changchun 130021, China
| | - Yulai Song
- Key Laboratory of Automobile Materials, Ministry of Education, College of Materials Science and Engineering, Jilin University, Changchun 130021, China
| | - Wenzhou Xu
- Department of Periodontology, School and Hospital of Stomatology, Jilin University, Changchun 130021, China
- Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering, Changchun 130021, China
| | - Lan A
- Department of Oral Implantology, School and Hospital of Stomatology, Jilin University, Changchun 130021, China
- Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering, Changchun 130021, China
| |
Collapse
|
34
|
Dsouza FP, Dinesh S, Sharma S. Understanding the intricacies of microbial biofilm formation and its endurance in chronic infections: a key to advancing biofilm-targeted therapeutic strategies. Arch Microbiol 2024; 206:85. [PMID: 38300317 DOI: 10.1007/s00203-023-03802-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 12/04/2023] [Accepted: 12/16/2023] [Indexed: 02/02/2024]
Abstract
Bacterial biofilms can adhere to various surfaces in the environment with human beings being no exception. Enclosed in a self-secreted matrix which contains extracellular polymeric substances, biofilms are intricate communities of bacteria that play a significant role across various sectors and raise concerns for public health, medicine and industries. These complex structures allow free-floating planktonic cells to adopt multicellular mode of growth which leads to persistent infections. This is of great concern as biofilms can withstand external attacks which include antibiotics and immune responses. A more comprehensive and innovative approach to therapy is needed in view of the increasing issue of bacterial resistance brought on by the overuse of conventional antimicrobial medications. Thus, to oppose the challenges posed by biofilm-related infections, innovative therapeutic strategies are being explored which include targeting extracellular polymeric substances, quorum sensing, and persister cells. Biofilm-responsive nanoparticles show promising results by improving drug delivery and reducing the side effects. This review comprehensively examines the factors influencing biofilm formation, host immune defence mechanisms, infections caused by biofilms, diagnostic approaches, and biofilm-targeted therapies.
Collapse
Affiliation(s)
| | - Susha Dinesh
- Department of Bioinformatics, BioNome, Bengaluru, Karnataka, 560043, India.
| | - Sameer Sharma
- Department of Bioinformatics, BioNome, Bengaluru, Karnataka, 560043, India
| |
Collapse
|
35
|
Eram A, Vinay Kr R, K N C, Keni LG, Shetty DD, Zuber M, Kumar S, S P. Air-Abrasion in Dentistry: A Short Review of the Materials and Performance Parameters. J Biomed Phys Eng 2024; 14:99-110. [PMID: 38357598 PMCID: PMC10862117 DOI: 10.31661/jbpe.v0i0.2310-1670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/27/2023] [Indexed: 02/16/2024]
Abstract
The selection of abrasive material and parameters of the Air-Abrasion device for a particular application is a crucial detail. However, there are no standard recommendations or manuals for choosing these details; the operator must depend on his experience and knowledge of the procedure to select the best possible material and set of parameters. This short review attempts to identify some of the effects that the selection of material and parameters could have on the performance of the Air-Abrasion procedure for a particular application. The material and parameter data are collected from various studies and categorized according to the most popular materials in use right now. These studies are then analyzed to arrive at some inferences on the performance of Air-Abrasion materials and parameters. This review arrives at a few conclusions on the effectiveness of a material and parameter set, and that there is potential for developments in the area of standardizing parameter selection; also, there is scope for further studies on Bio-Active Glass as an alternative to the materials currently used in Air-Abrasion.
Collapse
Affiliation(s)
- Afiya Eram
- Department of Conservative Dentistry and Endodontics, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education, Manipal, India
| | - Rajath Vinay Kr
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal, India
| | - Chethan K N
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal, India
| | - Laxmikant G Keni
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal, India
| | - Divya D Shetty
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal, India
| | - Mohammad Zuber
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal, India
| | - Saurabh Kumar
- Department of Pediatric & Preventive Dentistry, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education, Manipal, India
| | - Pradeep S
- Department of Prosthodontics & Crown and Bridge, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education, Manipal, India
| |
Collapse
|
36
|
Juárez-Cepeda J, Valenzuela O, Garibay-Valdez E, Velazquez C, Garibay-Escobar A. Gene expression during the development of Mycobacterium smegmatis biofilms on hydroxyapatite surfaces. Int Microbiol 2024; 27:257-263. [PMID: 37311924 DOI: 10.1007/s10123-023-00385-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 05/19/2023] [Accepted: 05/31/2023] [Indexed: 06/15/2023]
Abstract
Bacterial biofilms are a consortium of bacteria that are strongly bound to each other and the surface on which they developed irreversibly. Bacteria can survive adverse environmental conditions and undergo changes when transitioning from a planktonic form to community cells. The process of mycobacteria adhesion is complex, involving characteristics and properties of bacteria, surfaces, and environmental factors; therefore, the formation of different biofilms is possible. Cell wall-, lipid-, and lipid transporter-related genes (glycopeptidolipids, GroEL1, protein kinase) are important in mycobacterial biofilm development. We investigated gene expression during in vitro development of Mycobacterium smegmatis biofilms on a hydroxyapatite (HAP) surface. Biofilm formation by M. smegmatis cells was induced for 1, 2, 3, and 5 days on the HAP surface. Mycobacteria on polystyrene generated an air-liquid interface biofilm, and on the fifth day, it increased by 35% in the presence of HAP. Six genes with key roles in biofilm formation were analyzed by real-time RT‒qPCR during the biofilm formation of M. smegmatis on both abiotic surfaces. The expression of groEL1, lsr2, mmpL11, mps, pknF, and rpoZ genes during biofilm formation on the HAP surface did not exhibit significant changes compared to the polystyrene surface. These genes involved in biofilm formation are not affected by HAP.
Collapse
Affiliation(s)
- Jacqueline Juárez-Cepeda
- Departmento de Ciencias Químico Biológicas, Universidad de Sonora, Rosales y Luis Encinas S/N, 83000, Hermosillo, Sonora, México
| | - Olivia Valenzuela
- Departmento de Ciencias Químico Biológicas, Universidad de Sonora, Rosales y Luis Encinas S/N, 83000, Hermosillo, Sonora, México
| | - Estefanía Garibay-Valdez
- Centro de Investigación en Alimentación y Desarrollo, A. C. Km 0.6 Carretera a La Victoria, Hermosillo, Sonora, México
| | - Carlos Velazquez
- Departmento de Ciencias Químico Biológicas, Universidad de Sonora, Rosales y Luis Encinas S/N, 83000, Hermosillo, Sonora, México
| | - Adriana Garibay-Escobar
- Departmento de Ciencias Químico Biológicas, Universidad de Sonora, Rosales y Luis Encinas S/N, 83000, Hermosillo, Sonora, México.
| |
Collapse
|
37
|
Han SA, Kim S, Seo Y, Yang SK, Rhee CS, Han DH. Dental implant as a potential risk factor for maxillary sinus fungus ball. Sci Rep 2024; 14:2483. [PMID: 38291074 PMCID: PMC10827791 DOI: 10.1038/s41598-024-52661-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 01/22/2024] [Indexed: 02/01/2024] Open
Abstract
Fungus ball is the most common form of non-invasive fungal sinusitis, and maxillary sinus is the most commonly involved site. Maxillary sinus fungus ball (MFB) accounts for a considerable proportion of unilateral maxillary sinusitis. The prevalence of MFB has recently increased; however, its contributing factors are unclear. This study analyzed the association between MFB and dental implants. One hundred one patients who underwent unilateral maxillary sinus surgery were divided into two groups based on surgical biopsy results: unilateral bacterial sinusitis (UBS, n = 45) and MFB (n = 56). Stratified random sampling of 30 patients from each group was performed to adjust for age. The number of dental implants on maxillary teeth and degree of penetration into the maxillary sinus was radiologically evaluated. The number of patients with dental implants was greater (P = 0.085) and the number of implants was significantly higher (P = 0.031) in the MFB group. Dental implant can be a potential risk factor for MFB development. Therefore, dental implant surgeons should take caution in penetrating the maxillary sinus floor during implant insertion and otolaryngologists should consider the possibility of fungus ball when assessing patients with sinusitis who have dental implants.
Collapse
Affiliation(s)
- Sun A Han
- Department of Otorhinolaryngology-Head and Neck Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Republic of Korea
| | - Sungtae Kim
- Department of Periodontology, Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Yuju Seo
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Daehakro 101, Jongno-gu, Seoul, Republic of Korea
| | - Seung Koo Yang
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Daehakro 101, Jongno-gu, Seoul, Republic of Korea
| | - Chae-Seo Rhee
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Daehakro 101, Jongno-gu, Seoul, Republic of Korea
- Graduate School of Immunology, Seoul National University College of Medicine, Seoul, Republic of Korea
- Institute of Allergy and Clinical Immunology and Sensory Organ Research Institute, Seoul National University Biomedical Research Center, Seoul, Republic of Korea
- Sensory Organ Research Institute, Seoul National University Biomedical Research Center, Seoul, Republic of Korea
| | - Doo Hee Han
- Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University College of Medicine, Daehakro 101, Jongno-gu, Seoul, Republic of Korea.
| |
Collapse
|
38
|
Papadopoulos C, Larue AE, Toulouze C, Mokhtari O, Lefort J, Libert E, Assémat P, Swider P, Malaquin L, Davit Y. A versatile micromodel technology to explore biofilm development in porous media flows. LAB ON A CHIP 2024; 24:254-271. [PMID: 38059908 DOI: 10.1039/d3lc00293d] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/08/2023]
Abstract
Bacterial biofilms that grow in porous media are critical to ecosystem processes and applications ranging from soil bioremediation to bioreactors for treating wastewater or producing value-added products. However, understanding and engineering the complex phenomena that drive the development of biofilms in such systems remains a challenge. Here we present a novel micromodel technology to explore bacterial biofilm development in porous media flows. The technology consists of a set of modules that can be combined as required for any given experiment and conveniently tuned for specific requirements. The core module is a 3D-printed micromodel where biofilm is grown into a perfusable porous substrate. High-precision additive manufacturing, in particular stereolithography, is used to fabricate porous scaffolds with precisely controlled architectures integrating flow channels with diameters down to several hundreds of micrometers. The system is instrumented with: ultraviolet-C light-emitting diodes; on-line measurements of oxygen consumption and pressure drop across the porous medium; camera and spectrophotometric cells for the detection of biofilm detachment events at the outlet. We demonstrate how this technology can be used to study the development of Pseudomonas aeruginosa biofilm for several days within a network of flow channels. We find complex dynamics whereby oxygen consumption reaches a steady-state but not the pressure drop, which instead features a permanent regime with large fluctuations. We further use X-ray computed microtomography to image the spatial distribution of biofilms and computational fluid dynamics to link biofilm development with local flow properties. By combining the advantages of additive manufacturing for the creation of reproducible 3D porous microarchitectures with the flow control and instrumentation accuracy of microfluidics, our system provides a platform to study the dynamics of biofilm development in 3D porous media and to rapidly test new concepts in process engineering.
Collapse
Affiliation(s)
- Christos Papadopoulos
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
- LAAS-CNRS, CNRS & Université de Toulouse, 31400 Toulouse, France
| | - Anne Edith Larue
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
- Transverse Lab, 271 rue des Fontaines, 31300 Toulouse, France
| | - Clara Toulouze
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
| | - Omar Mokhtari
- Physikalisches Institut, Universität Bern, Gesellschaftsstrasse 6, 3012 Bern, Switzerland
| | - Julien Lefort
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
| | - Emmanuel Libert
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
| | - Pauline Assémat
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
| | - Pascal Swider
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
| | - Laurent Malaquin
- LAAS-CNRS, CNRS & Université de Toulouse, 31400 Toulouse, France
| | - Yohan Davit
- Institut de Mécanique des Fluides (IMFT), CNRS & Université de Toulouse, 31400 Toulouse, France.
| |
Collapse
|
39
|
Hernández-Escobar D, Pajares-Chamorro N, Chatzistavrou X, Hankenson KD, Hammer ND, Boehlert CJ. Tailored Coatings for Enhanced Performance of Zinc-Magnesium Alloys in Absorbable Implants. ACS Biomater Sci Eng 2024; 10:338-354. [PMID: 38109649 DOI: 10.1021/acsbiomaterials.3c01255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2023]
Abstract
Absorbable metals exhibit potential for next-generation temporary medical implants, dissolving safely in the body during tissue healing and regeneration. Their commercial incorporation could substantially diminish the need for additional surgeries and complications that are tied to permanent devices. Despite extensive research on magnesium (Mg) and iron (Fe), achieving the optimal combination of mechanical properties, biocompatibility, and controlled degradation rate for absorbable implants remains a challenge. Zinc (Zn) and Zn-based alloys emerged as an attractive alternative for absorbable implants, due to favorable combination of in vivo biocompatibility and degradation behavior. Moreover, the development of suitable coatings can enhance their biological characteristics and tailor their degradation process. In this work, four different biodegradable coatings (based on zinc phosphate (ZnP), collagen (Col), and Ag-doped bioactive glass nanoparticles (AgBGNs)) were synthesized by chemical conversion, spin-coating, or a combination of both on Zn-3Mg substrates. This study assessed the impact of the coatings on in vitro degradation behavior, cytocompatibility, and antibacterial activity. The ZnP-coated samples demonstrated controlled weight loss and a decreased corrosion rate over time, maintaining a physiological pH. Extracts from the uncoated, ZnP-coated, and Col-AgBGN-coated samples showed higher cell viability with increasing concentration. Bacterial viability was significantly impaired in all coated samples, particularly in the Col-AgBGN coating. This study showcases the potential of a strategic material-coating combination to effectively tackle multiple challenges encountered in current medical implant technologies by modifying the properties of absorbable metals to tailor patient treatments.
Collapse
Affiliation(s)
- David Hernández-Escobar
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, Michigan 48824, United States
| | - Natalia Pajares-Chamorro
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, Michigan 48824, United States
| | - Xanthippi Chatzistavrou
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, Michigan 48824, United States
- Department of Chemical Engineering, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Kurt D Hankenson
- Department of Orthopedic Surgery, University of Michigan, Ann Arbor, Michigan 48104, United States
| | - Neal D Hammer
- Department of Microbiology and Molecular Genetics, Michigan State University, East Lansing, Michigan 48824, United States
| | - Carl J Boehlert
- Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, Michigan 48824, United States
| |
Collapse
|
40
|
Özarslan M, Avcioglu NH, Bilgili Can D, Çalışkan A. Biofilm formation of C. albicans on occlusal device materials and antibiofilm effects of chitosan and eugenol. J Prosthet Dent 2024; 131:144.e1-144.e9. [PMID: 38167132 DOI: 10.1016/j.prosdent.2023.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 10/05/2023] [Accepted: 10/05/2023] [Indexed: 01/05/2024]
Abstract
STATEMENT OF PROBLEM Microbial adhesion on occlusal devices may lead to oral diseases such as candidiasis. Whether chitosan and eugenol provide antibiofilm effects is unclear. PURPOSE The purpose of this in vitro study was to evaluate the biofilm formation of C. albicans strains on occlusal device materials and the antibiofilm effects of chitosan and eugenol against C. albicans on these surfaces. MATERIAL AND METHODS A total of 88 specimens (5×10×2 mm) were produced from occlusal device materials with 4 production techniques: vacuum-formed thermoplastic (Group V), head-press (Group H), computer-aided design and computer-aided manufacture (CAD-CAM) (Group C), and 3-dimensionally (3D) printed (Group D) (n=22). After various finishing procedures, the surface properties of the specimens were evaluated by using surface free energy (SFE), surface roughness (SR) measurements, and elemental and topographic analysis. Biofilm formation of C. albicans strain and the antibiofilm effects of chitosan and eugenol against biofilm formation on these surfaces were also examined with a crystal violet assay. The distribution's normality was statistically analyzed with the Kolmogorov-Smirnov test. One-way and two-way analysis of variance with post hoc Tukey tests were used for statistical evaluations (α=.05). RESULTS Surface roughness values in Groups D and H were significantly higher than in other groups (P<.05). While the highest surface free energy values (except γp) were in Group V, Group C had the highest γp. The lowest biofilm value appeared in Group H. Chitosan exhibited an antibiofilm effect in all groups except Group H, while eugenol was effective in all groups. CONCLUSIONS The production method affected the susceptibility of occlusal device materials to the adhesion of C. albicans. Eugenol was an effective antibiofilm agent for device materials.
Collapse
Affiliation(s)
- Merve Özarslan
- Associate Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Akdeniz University, Antalya, Turkey.
| | - Nermin Hande Avcioglu
- Research Assistant, Department of Biology, Biotechnology Section, Faculty of Science, Hacettepe University, Ankara, Turkey
| | - Dilber Bilgili Can
- Associate Professor, Department of Restorative Dentistry, Faculty of Dentistry, Van Yuzuncu Yil University, Van, Turkey
| | | |
Collapse
|
41
|
Man K, Mazumder S, Dahotre NB, Yang Y. Surface Nanostructures Enhanced Biocompatibility and Osteoinductivity of Laser-Additively Manufactured CoCrMo Alloys. ACS OMEGA 2023; 8:47658-47666. [PMID: 38144145 PMCID: PMC10734289 DOI: 10.1021/acsomega.3c04305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 09/19/2023] [Indexed: 12/26/2023]
Abstract
Cobalt-chromium-molybdenum (CoCrMo) alloys are widely used in orthopedic implants due to their excellent corrosion and wear resistance and superior mechanical properties. However, their limited capability to promote cell adhesion and new bone tissue formation, poor blood compatibility, and risk of microbial infection can lead to implant failure or reduced implant lifespan. Surface structure modification has been used to improve the cytocompatibility and blood compatibility of implant materials and reduce the risk of infection. In this study, we prepared CoCrMo alloys with surface nanostructures of various aspect ratios (AR) using laser-directed energy deposition (L-DED) and biocorrosion. Our results showed that medium and high AR nanostructures reduced platelet adhesion, while all of the alloys demonstrated good blood compatibility and antibacterial properties. Moreover, the medium and high AR nanostructures promoted cell adhesion and spreading of both preosteoblast MC3T3 cells and human bone marrow mesenchymal stem cells (hMSCs). Furthermore, the nanostructure promoted the osteogenic differentiation of both cell types compared with the flat control surface, with a substantial enhancing effect for the medium and high ARs. Our study proposes a promising approach for developing implant materials with improved clinical outcomes.
Collapse
Affiliation(s)
- Kun Man
- Department
of Biomedical Engineering, University of
North Texas, Denton, Texas 76207, United States
- Center
for Agile and Adaptive Additive Manufacturing, University of North Texas, Denton, Texas 76207, United States
| | - Sangram Mazumder
- Center
for Agile and Adaptive Additive Manufacturing, University of North Texas, Denton, Texas 76207, United States
- Department
of Materials Science and Engineering, University
of North Texas, Denton, Texas 76207, United States
| | - Narendra B. Dahotre
- Center
for Agile and Adaptive Additive Manufacturing, University of North Texas, Denton, Texas 76207, United States
- Department
of Materials Science and Engineering, University
of North Texas, Denton, Texas 76207, United States
| | - Yong Yang
- Department
of Biomedical Engineering, University of
North Texas, Denton, Texas 76207, United States
| |
Collapse
|
42
|
Tahmawy YA, Mohamed FS, Elfeki S, Abd-Ellah ME. Microbiological evaluation of conjunctival anopthalmic flora after using digital 3D-printed ocular prosthesis compared to conventional one: a randomized clinical trial. BMC Oral Health 2023; 23:1012. [PMID: 38110937 PMCID: PMC10729395 DOI: 10.1186/s12903-023-03746-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Accepted: 12/07/2023] [Indexed: 12/20/2023] Open
Abstract
BACKGROUND This study aims to assess the influence of using 3D-printed acrylic resin versus conventional Poly-methyl methacrylate (PMMA) for fabricating ocular prostheses on the biofilm and microbial flora of anophthalmic socket. METHODS A randomized controlled trial was designed as a parallel group study. Participants were allocated randomly into two groups: the control group, which received conventionally fabricated ocular prostheses (CG, n = 11), and the test group, which received digitally 3D-printed ocular prostheses (DG, n = 11). Microbiological analysis was conducted before prosthesis insertion and three months after using the ocular prosthesis. Swab samples were inoculated on blood agar, MacConkey's agar, and Sabouraud's dextrose agar (SDA) for isolating Gram-positive, Gram-negative, and fungal organisms, respectively. Subsequently, the plates were incubated at 37 degrees Celsius for 48 h. Additionally, a validated questionnaire was used for subjective clinical evaluation, including parameters such as comfort level, socket discharge, lacrimation, and frequency of lubrication for each ocular prosthesis patient in both groups. RESULTS Test group (DG, n = 11) exhibited a positive, though statistically insignificant, difference (p > 0.001) in microbial growth when compared to the control group (CG, n = 11). A statistically significant difference was observed in comfort levels between the two groups, with more comfort level within group II (test group) patients. While parameters such as discharge amount, discharge location, lacrimation and lubrication frequency displayed statistically insignificant differences between the two groups, all parameters showed improved results after three months of prosthesis use. CONCLUSIONS The choice of ocular prosthesis fabrication technique did not yield a statistically significant difference in anophthalmic flora. However, the 3D-printed acrylic resin, as an artificial eye material, displayed potential advantages in reducing the colonization of opportunistic pathogens. All subjective clinical evaluation parameters exhibited enhanced outcomes after three months of prosthesis use, emphasizing the need for an adaptation period during which patients complains are alleviated. In comparison with PMMA, 3D-printed acrylic resin showcased a certain degree of anti-colonization ability against pathogenic bacteria, along with a significant level of patient comfort, suggesting its potential as a promising material for ocular prostheses. TRIAL REGISTRATION This parallel double-blinded RCT has been registered at ClinicalTrials.gov with identification number: NCT05584865, 18/10/2022.
Collapse
Affiliation(s)
- Yassmin A Tahmawy
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Champollion Street, Azarita, Alexandria, 002034868066, Egypt.
| | - Faten S Mohamed
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Champollion Street, Azarita, Alexandria, 002034868066, Egypt
| | - Suzan Elfeki
- Department of Microbiology, Faculty of Medicine, Alexandria University, Alexandria, Egypt
| | - Mervat E Abd-Ellah
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Champollion Street, Azarita, Alexandria, 002034868066, Egypt
| |
Collapse
|
43
|
Al-Kilani J, Al-Kilani S, Chrcanovic BR. Difference in marginal bone loss around implants between short implant-supported partial fixed prostheses with and without cantilever: a retrospective clinical study. Int J Implant Dent 2023; 9:46. [PMID: 38036796 PMCID: PMC10689685 DOI: 10.1186/s40729-023-00515-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 11/21/2023] [Indexed: 12/02/2023] Open
Abstract
PURPOSE To investigate the influence of cantilever prosthetic arm on the marginal bone loss (MBL) over time around dental implants supporting short fixed partial dentures (FPDs), in a record-based retrospective study. METHODS All cases of 3-unit implant-supported FPDs, supported by 2-3 implants, from the database of cases treated at one specialist clinic were considered for inclusion. Only implants with a minimum of 36 months of radiological follow-up were considered. Univariate linear regression models were used to compare MBL over time between 12 clinical covariates, after which a linear mixed-effects model was built. RESULTS One-hundred-thirty-nine patients (64 men, 75 women) with 164 3-unit implant-supported FPDs (333 implants supporting non-cantilevered FPDs, 94 supporting cantilevered FPDs) were included in the study. The patients were followed up clinically and radiographically for a mean of 154.1 ± 78.0 (min-max, 37.3-364.6) and 132.9 ± 77.3 months (min-max, 36.8-329.9), respectively. The total number of marginal bone level double measurements (mesial and distal sides of each implant) was 2909. FPDs with cantilever presented an estimated greater MBL over time compared to FPDs without cantilever. Bruxism, sex (women), implant (modified) surface, and (poor) bone quality were also associated with higher MBL over time. CONCLUSIONS The use of a cantilever extension is suggested to negatively affect the bone marginal level over time around implants supporting 3-unit FPDs. Due to the small difference of the estimated MBL over long periods of follow-up between the groups, it is a matter of debate if the observed negative effect may be of clinical significance.
Collapse
|
44
|
Wang D, Yu J, Liu H, Zhang T, Haney EF, Hancock REW, Peng L, Shen Y. Influence of a D-enantiomeric peptide on the anticorrosion ability of titanium with different surface roughness against Streptococcus mutans biofilms. J Dent 2023; 139:104777. [PMID: 37944630 DOI: 10.1016/j.jdent.2023.104777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/05/2023] [Accepted: 11/06/2023] [Indexed: 11/12/2023] Open
Abstract
OBJECTIVE To investigate the effectiveness of a d-enantiomeric antibiofilm peptide (DJK-5) on the anticorrosion ability of titanium (Ti) with different surface roughness against Streptococcus mutans biofilms. METHODS Commercially pure Ti disks with machined (MA, smooth) or sandblasted + acid-etched (SLA, rough) surfaces were prepared and characterized. All disks were divided into three groups: a positive control (PC) group with S. mutans, a DJK-5-treated group, and a negative control (NC) group without S. mutans. Biofilm formation and corrosion on Ti surfaces were determined by confocal laser scanning microscopy and scanning electron microscopy after 2 and 6 days, and the electrochemical properties were evaluated. RESULTS Ten μg/mL of DJK-5 killed 83.3 % and 87.4 % of biofilms on SLA and MA Ti surfaces, respectively after 2 days, and 72.9 % and 77.7 % after 6 days, with more bacteria surviving on SLA surfaces with higher roughness (p < 0.05). DJK-5 treatment induced less surface defects with tiny pit corrosion than PC. DJK-5 treatment when compared to PC, led to electrochemical properties more reflecting NC surfaces, including significantly less negative corrosion potential, lower corrosion current, and higher passive film resistance (p < 0.05). SLA surfaces exhibited higher current density and lower resistance than MA surfaces (p < 0.05). CONCLUSION DJK-5 effectively enhanced the corrosion resistance of Ti with different surface roughness while killing S. mutans biofilms, and smooth surfaces were more susceptible to peptide treatment. CLINICAL SIGNIFICANCE The antibiofilm peptide is promising for promoting the anticorrosion ability of Ti against biofilms, thereby preventing biofilm-related infections.
Collapse
Affiliation(s)
- Dan Wang
- Department of Stomatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China; Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, Canada
| | - Jian Yu
- Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, Canada; State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
| | - He Liu
- Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, Canada
| | - Tian Zhang
- School of Medicine, Vanderbilt University, Nashville, TN, United States
| | - Evan F Haney
- Centre for Microbial Diseases and Immunity Research, Department of Microbiology and Immunology, University of British Columbia, Vancouver, Canada
| | - Robert E W Hancock
- Centre for Microbial Diseases and Immunity Research, Department of Microbiology and Immunology, University of British Columbia, Vancouver, Canada
| | - Lin Peng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| | - Ya Shen
- Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, Canada.
| |
Collapse
|
45
|
Tarabal VS, Abud YKD, da Silva FG, da Cruz LF, Fontes GN, da Silva JA, Filho CBS, Sinisterra RD, Granjeiro JM, Granjeiro PA. Effect of DMPEI coating against biofilm formation on PVC catheter surface. World J Microbiol Biotechnol 2023; 40:6. [PMID: 37932532 DOI: 10.1007/s11274-023-03799-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 10/09/2023] [Indexed: 11/08/2023]
Abstract
Urinary tract infections (UTIs) are a significant cause of morbidity in healthcare systems and are prominently associated with applying urethral catheters, particularly in surgeries. Polyvinyl chloride (PVC) is extensively utilized in the fabrication of catheters. Biofilms, complex polymeric constructions, provide a protective milieu for cell multiplication and the enhancement of antibiotic resistance. Strategies to counteract biofilm development on medical apparatuses' surfaces incorporate antimicrobial agents such as N,N-dodecyl, and methyl polyethylenimine (DMPEI). This research endeavored to characterize the morphology of PVC and PVC-DMPEI surfaces utilizing Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM) and to gauge hydrophobicity through contact angle measurements. Employing Escherichia coli, Staphylococcus aureus, and Candida albicans in adhesion assays enabled the assessment of DMPEI's efficacy in preventing microbial adherence to PVC. Butanol successfully solubilized 2 mg.mL-1 DMPEI without altering the PVC structure. SEM results substantiated the formation of a DMPEI layer on the PVC surface, which led to decreased surface roughness, as validated by AFM, and increased hydrophilicity, as demonstrated by contact angle evaluations. E. coli, S. aureus, and C. albicans exhibited significant adhesion reduction, 89.3%, 94.3%, and 86.6% on PVC-DMPEI surfaces. SEM visualizations confirmed reduced cellular colonization on PVC-DMPEI and highlighted considerable morphological modifications in E. coli. Consequently, DMPEI films effectively minimize the adhesion of E. coli, S. aureus, and C. albicans on PVC surfaces. DMPEI, with its potential as a protective coating for innovative medical devices, promises to inhibit biofilm adherence effectively.
Collapse
Affiliation(s)
- Vinícius S Tarabal
- Campus Centro Oeste, Federal University of São João Del-Rei, Av. Sebastião Gonçalves Coelho, 400 Bairro Chanadour, Divinópolis, MG, 35501-296, Brazil
| | - Yuri K D Abud
- National Institute of Metrology, Quality and Technology, Av. Nossa Sra. das Graças, 50 - Xerém, Duque de Caxias, RJ, 25250-020, Brazil
| | - Flávia G da Silva
- Chemistry Department, Federal University of Minas Gerais, Av. Antônio Carlos, 6627, Belo Horizonte, MG, 31270-901, Brazil
| | - Luisa F da Cruz
- Campus Centro Oeste, Federal University of São João Del-Rei, Av. Sebastião Gonçalves Coelho, 400 Bairro Chanadour, Divinópolis, MG, 35501-296, Brazil
| | - Giselle N Fontes
- National Institute of Metrology, Quality and Technology, Av. Nossa Sra. das Graças, 50 - Xerém, Duque de Caxias, RJ, 25250-020, Brazil
| | - Jose A da Silva
- Campus Centro Oeste, Federal University of São João Del-Rei, Av. Sebastião Gonçalves Coelho, 400 Bairro Chanadour, Divinópolis, MG, 35501-296, Brazil
| | - Celso B S Filho
- National Institute of Metrology, Quality and Technology, Av. Nossa Sra. das Graças, 50 - Xerém, Duque de Caxias, RJ, 25250-020, Brazil
| | - Ruben D Sinisterra
- Chemistry Department, Federal University of Minas Gerais, Av. Antônio Carlos, 6627, Belo Horizonte, MG, 31270-901, Brazil
| | - Jose M Granjeiro
- National Institute of Metrology, Quality and Technology, Av. Nossa Sra. das Graças, 50 - Xerém, Duque de Caxias, RJ, 25250-020, Brazil
- Fluminense Federal University, R. Mario Santos Braga, 28 - Centro, Niteroi, RJ, 24020-150, Brazil
| | - Paulo A Granjeiro
- Campus Centro Oeste, Federal University of São João Del-Rei, Av. Sebastião Gonçalves Coelho, 400 Bairro Chanadour, Divinópolis, MG, 35501-296, Brazil.
| |
Collapse
|
46
|
Atalay S, Çakmak G, Fonseca M, Schimmel M, Yilmaz B. Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials. J Prosthet Dent 2023; 130:787-795. [PMID: 35148889 DOI: 10.1016/j.prosdent.2021.12.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 12/07/2021] [Accepted: 12/07/2021] [Indexed: 02/04/2023]
Abstract
STATEMENT OF PROBLEM Which disinfection protocol provides optimal water contact angle and microhardness for computer-aided design and computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA) materials is unclear. PURPOSE The purpose of this in vitro study was to evaluate the effect of different disinfection protocols (1% sodium hypochlorite, denture cleanser gel, and effervescent tablet) on the water contact angle and microhardness of different CAD-CAM PMMA denture base materials by comparing them with a heat-polymerized PMMA. MATERIAL AND METHODS Disk-shaped specimens (Ø10×2 mm) were fabricated from 3 different CAD-CAM PMMAs-AvaDent (AV), Merz M-PM (M-PM), and Polident (Poli)-and a heat-polymerized PMMA (Vynacron) (CV) (n=21). Three disinfection protocols (1% sodium hypochlorite [HC], denture cleanser gel [GEL], an effervescent tablet [TAB]) were applied to simulate 180 days of cleansing. The water contact angle and microhardness of specimens were measured before and after disinfection and compared by using a 2-way ANOVA (α=.05). RESULTS For water contact angle, material (P=.010) and disinfection protocol (P=.002) had a significant effect. The material (P<.001), disinfection protocol (P=.001), and their interaction (P<.001) significantly affected the microhardness after disinfection. When the condition after disinfection was compared with that before disinfection, the water contact angle increased significantly in all material-disinfection protocol pairs (P≤.025), and microhardness increased significantly in all material-disinfection protocol pairs (P≤.040), except for GEL- (P=.689) or TAB-applied (P=.307) AV, HC-applied M-PM (P=.219), and TAB-applied Poli (P=.159). CONCLUSIONS The material and disinfection protocol affected the water contact angle of all tested PMMAs after disinfection, resulting in more hydrophobic surfaces for heat-polymerized or CAD-CAM PMMAs. The microhardness of heat-polymerized PMMA was less than that of all CAD-CAM PMMAs after disinfection, regardless of the protocol.
Collapse
Affiliation(s)
- Sevda Atalay
- Assistant Professor, Department of Prosthodontics, Istanbul Okan University, Faculty of Dentistry, Istanbul, Turkey
| | - Gülce Çakmak
- Buser Foundation Scholar for Implant Dentistry, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Manrique Fonseca
- Senior Lecturer, Department of Reconstructive Dentistry and Gerodontology. School of Dental Medicine University of Bern, Bern, Switzerland.
| | - Martin Schimmel
- Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; External Researcher, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
47
|
Lin IP, Chang CC, Tu CC, Lai CL, Su FY. Efficacy of free gingival grafting to augment keratinized mucosa around dental implants in posterior regions after restorative procedures: A retrospective clinical study. J Prosthet Dent 2023; 130:715-722. [PMID: 35000695 DOI: 10.1016/j.prosdent.2021.12.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 12/01/2021] [Accepted: 12/01/2021] [Indexed: 01/22/2023]
Abstract
STATEMENT OF PROBLEM Data on the shrinkage of free gingival grafts (FGGs) vary. Most studies have analyzed grafts in nonmolar sites because of measurement limitations and have addressed the changes in grafts and keratinized mucosa width (KMW) only in the early healing phase. PURPOSE The purpose of this retrospective clinical study was to assess the dimensional changes of an FGG in the posterior regions and their influencing factors, with the aim of obtaining sufficient and stable KMW after restoration. MATERIAL AND METHODS A total of 77 implants in 40 participants who had undergone an FGG surgery were recruited. Graft sizes during surgery and the surface areas of keratinized mucosa at the follow-up visit after restorations were compared by digital analysis and verified by clinical measurements and photographs. The association between shrinkage and the graft sizes, implant location, and sex and age of the participants was evaluated. The influence of the shrinkage of FGG on the KMW after restoration was analyzed by multivariable linear regression with generalized estimating equation (GEE) models. RESULTS The mean ±standard deviation shrinkage of FGG around implants in the posterior regions was 24.76 ±14.77%, and the mean ±standard deviation KMW was 4.16 ±1.77 mm at the follow-up visit. Larger grafts had a statistically higher shrinkage ratio (P<.001). No statistically significant difference was found regarding the effect of implant location, sex, and age on the shrinkage of FGG and final KMW (P>.05). The mean ±standard deviation follow-up period after restoration was 12.45 ±7.73 months CONCLUSIONS: Free gingival grafting was found to be a predictable treatment approach for augmentation of KMW around implants in the posterior region after the fabrication of prostheses as long as grafts of sufficient size were placed. Stable outcomes were shown in the study participants in the follow-up period of up to 3 years.
Collapse
Affiliation(s)
- I-Ping Lin
- Clinical Instructor/Director, Division of Periodontology, Department of Dentistry, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu City, Taiwan, ROC; Lecturer, Graduate Institute of Clinical Dentistry, School of Dentistry, College of Medicine, National Taiwan University, Taipei City, Taiwan, ROC
| | - Chung-Chieh Chang
- Clinical Instructor, Division of Periodontology, Department of Dentistry, Chang Gung Memorial Hospital Linkou Main Branch and Chang Gung University, Taoyuan City, Taiwan, ROC.
| | - Chia-Chun Tu
- Graduate student, Graduate Institute of Clinical Dentistry, School of Dentistry, College of Medicine, National Taiwan University, Taipei City, Taiwan, ROC
| | - Chao-Lun Lai
- Director, Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei City, Taiwan, ROC
| | - Fang-Ying Su
- Statistical Technician, Department of Medical Research, National Taiwan University Hsin-Chu Branch, Hsinchu, Taiwan, ROC
| |
Collapse
|
48
|
Lyons KM, Cannon RD, Beumer J, Bakr MM, Love RM. Microbial Analysis of Obturators During Maxillofacial Prosthodontic Treatment Over an 8-Year Period. Cleft Palate Craniofac J 2023; 60:1426-1441. [PMID: 35642284 DOI: 10.1177/10556656221104940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The aim of the study was to investigate the microbial colonization (by Candida species, anaerobic and facultative anaerobic bacteria) of maxillary obturators used for the restoration of maxillary defects, including during radiotherapy. Retrospective cohort study. Fifteen patients requiring a maxillary obturator prosthesis had swabs of their obturators and adjacent tissues taken at different stages of their treatment over a period of 8 years. Identification of microbial species from the swabs was carried out using randomly amplified polymorphic DNA polymerase chain reaction (RAPD PCR) analysis, checkerboard DNA-DNA hybridization, CHROMagar Candida chromogenic agar, and DNA sequencing. Candida species were detected in all patients and all patients developed mucositis and candidiasis during radiotherapy which was associated with an increase in colonization of surfaces with Candida spp., particularly C albicans. Microbial colonization increased during radiotherapy and as an obturator aged, and decreased following a reline, delivery of a new prosthesis, or antifungal treatment during radiotherapy. Microbial colonization of maxillary obturators was related to the stage of treatment, age of the obturator material, radiotherapy and antifungal medications, and antifungal treatment may be recommended if C albicans colonization of palatal tissues is greater than 105 colony-forming units per cm2 following the first week of radiotherapy.
Collapse
Affiliation(s)
- Karl M Lyons
- Department of Oral Rehabilitation and Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Richard D Cannon
- Department of Oral Sciences and Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - John Beumer
- Division of Advanced Prosthodontics, School of Dentistry, University of California, Los Angeles, CA, USA
| | - Mahmoud M Bakr
- School of Medicine and Dentistry, Griffith University, Queensland, Australia
| | - Robert M Love
- School of Medicine and Dentistry, Griffith University, Queensland, Australia
| |
Collapse
|
49
|
Freitas JS, Souza LFB, Pereira GKR, May LG. Surface properties and flexural fatigue strength of an advanced lithium disilicate. J Mech Behav Biomed Mater 2023; 147:106154. [PMID: 37804677 DOI: 10.1016/j.jmbbm.2023.106154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 09/23/2023] [Accepted: 09/27/2023] [Indexed: 10/09/2023]
Abstract
The aim of this study was to evaluate the surface properties and fatigue mechanical behavior of an advanced lithium disilicate ceramic in comparison to lithium disilicate and zirconia. First, discs (n = 15, diameter = 13.5 mm and thickness = 1.2 mm) were made from the following materials: 4Y-PSZ - 4% mol yttria-stabilized zirconia (IPS e.max ZirCAD A2); LD - lithium disilicate (IPS e.max CAD); ALD - advanced lithium disilicate (CEREC Tessera). The specimens were crystalized/sintered and subsequently analyzed by a rugosimeter (Mitutoyo SJ-410) to determine surface roughness (parameters Ra and Rz). Specimens were subjected to biaxial flexural fatigue testing using the step-test method (20 Hz; 10,000 cycles per step; initial stress of 200 MPa; and step size of 25 MPa) until specimen fracture. Statistical analyses included Shapiro-Wilk, Kruskal-Wallis, and post-hoc tests for roughness data, while survival analysis (Kaplan-Meier and Mantel-Cox) and reliability analysis (Weibull modulus) were applied to flexural fatigue strength data. Hardness (Vickers) results were submitted to analysis of variance (1-way ANOVA) and Tukey's test. Zirconia (4Y-PSZ) showed higher FFS, CFF (467 MPa and 115216 cycles) and survival compared to the other materials. ALD had the lowest FFS, CFF (215 MPa and 11,908 cycles) and survival. ALD showed lower Weibull modulus (m = 6.63 for FFS; m = 1.27 for CFF) than LD for FFS (m = 17.33), and lower than LD (m = 4.64) and 4Y-PSZ (m = 6.69) for CFF. ALD showed the lowest Ra (0.07 μm) and Rz (1.05 μm) values, while 4Y-PSZ (Ra = 0.22 μm; Rz = 1.91 μm) and LD (Ra = 0.21 μm; Rz = 2.17 μm) showed higher and similar values. Zirconia (4-YPSZ) was the hardest material, while lithia-based ceramics (LD and ALD) presented the lowest and similar hardness values. Fractures originated in surface defects in the tensile stress concentration region. ALD has lower flexural fatigue strength compared to the other tested materials, along with higher variability (lower structural reliability).
Collapse
Affiliation(s)
- Júlia Saccol Freitas
- MSc and PhD Post-Graduate Program in Oral Science, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiza Freitas Brum Souza
- MSc and PhD Post-Graduate Program in Oral Science, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSc and PhD Post-Graduate Program in Oral Science, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Liliana Gressler May
- MSc and PhD Post-Graduate Program in Oral Science, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
50
|
Zhai S, Tian Y, Shi X, Liu Y, You J, Yang Z, Wu Y, Chu S. Overview of strategies to improve the antibacterial property of dental implants. Front Bioeng Biotechnol 2023; 11:1267128. [PMID: 37829564 PMCID: PMC10565119 DOI: 10.3389/fbioe.2023.1267128] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 09/14/2023] [Indexed: 10/14/2023] Open
Abstract
The increasing number of peri-implant diseases and the unsatisfactory results of conventional treatment are causing great concern to patients and medical staff. The effective removal of plaque which is one of the key causes of peri-implant disease from the surface of implants has become one of the main problems to be solved urgently in the field of peri-implant disease prevention and treatment. In recent years, with the advancement of materials science and pharmacology, a lot of research has been conducted to enhance the implant antimicrobial properties, including the addition of antimicrobial coatings on the implant surface, the adjustment of implant surface topography, and the development of new implant materials, and significant progress has been made in various aspects. Antimicrobial materials have shown promising applications in the prevention of peri-implant diseases, but meanwhile, there are some shortcomings, which leads to the lack of clinical widespread use of antimicrobial materials. This paper summarizes the research on antimicrobial materials applied to implants in recent years and presents an outlook on the future development.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Shunli Chu
- Jilin Provincial Key Laboratory of Tooth Development and Bone Remodeling, Hospital of Stomatology, Jilin University, Changchun, China
| |
Collapse
|