1
|
Tomar P. Impact of nanotechnology at heterogeneous interphases @ Sustainability. Heliyon 2024; 10:e26943. [PMID: 38449639 PMCID: PMC10915510 DOI: 10.1016/j.heliyon.2024.e26943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 02/21/2024] [Accepted: 02/21/2024] [Indexed: 03/08/2024] Open
Abstract
The 21st century information and communication industries have played the pivotal role of bio-sensing technologies, refining privacy policies for human performance, facilitating scientific innovation, shaping e-governance, and reinforcing public confidence using nanotechnology. Human body is a thermodynamic heat engine in providing effective mechanical work as a function of psyche, conventional fuel transformation into enriched protein meal, and balancing of work-life fulcrum. The triboelectric effect of rubbing surfaces, interfaces, and interphases is invincible from the large field of the planet to nanodomains.
Collapse
|
2
|
Brito C, Silva JV, Gonzaga RV, La-Scalea MA, Giarolla J, Ferreira EI. A Review on Carbon Nanotubes Family of Nanomaterials and Their Health Field. ACS OMEGA 2024; 9:8687-8708. [PMID: 38434894 PMCID: PMC10905599 DOI: 10.1021/acsomega.3c08824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 01/17/2024] [Accepted: 01/24/2024] [Indexed: 03/05/2024]
Abstract
The use of carbon nanotubes (CNTs), which are nanometric materials, in pathogen detection, protection of environments, food safety, and in the diagnosis and treatment of diseases, as efficient drug delivery systems, is relevant for the improvement and advancement of pharmacological profiles of many molecules employed in therapeutics and in tissue bioengineering. It has contributed to the advancement of science due to the development of new tools and devices in the field of medicine. CNTs have versatile mechanical, physical, and chemical properties, in addition to their great potential for association with other materials to contribute to applications in different fields of medicine. As, for example, photothermal therapy, due to the ability to convert infrared light into heat, in tissue engineering, due to the mechanical resistance, flexibility, elasticity, and low density, in addition to many other possible applications, and as biomarkers, where the electronic and optics properties enable the transduction of their signals. This review aims to describe the state of the art and the perspectives and challenges of applying CNTs in the medical field. A systematic search was carried out in the indexes Medline, Lilacs, SciELO, and Web of Science using the descriptors "carbon nanotubes", "tissue regeneration", "electrical interface (biosensors and chemical sensors)", "photosensitizers", "photothermal", "drug delivery", "biocompatibility" and "nanotechnology", and "Prodrug design" and appropriately grouped. The literature reviewed showed great applicability, but more studies are needed regarding the biocompatibility of CNTs. The data obtained point to the need for standardized studies on the applications and interactions of these nanostructures with biological systems.
Collapse
Affiliation(s)
- Charles
L. Brito
- Department
of Pharmacy, Faculty of Pharmaceutical Sciences, University of São Paulo, Avenida Professor Lineu Prestes, 580, Bloco 13, São Paulo CEP 05508-000, Brazil
| | - João V. Silva
- Department
of Pharmacy, Faculty of Pharmaceutical Sciences, University of São Paulo, Avenida Professor Lineu Prestes, 580, Bloco 13, São Paulo CEP 05508-000, Brazil
| | - Rodrigo V. Gonzaga
- Department
of Pharmacy, Faculty of Pharmaceutical Sciences, University of São Paulo, Avenida Professor Lineu Prestes, 580, Bloco 13, São Paulo CEP 05508-000, Brazil
| | - Mauro A. La-Scalea
- Department
of Chemistry, Federal University of São
Paulo, Diadema 09972-270, Brazil
| | - Jeanine Giarolla
- Department
of Pharmacy, Faculty of Pharmaceutical Sciences, University of São Paulo, Avenida Professor Lineu Prestes, 580, Bloco 13, São Paulo CEP 05508-000, Brazil
| | - Elizabeth I. Ferreira
- Department
of Pharmacy, Faculty of Pharmaceutical Sciences, University of São Paulo, Avenida Professor Lineu Prestes, 580, Bloco 13, São Paulo CEP 05508-000, Brazil
| |
Collapse
|
3
|
Gholami A, Mousavi SM, Masoumzadeh R, Binazadeh M, Bagheri Lankarani K, Omidifar N, Arjmand O, Chiang WH, Moghadami M, Pynadathu Rumjit N. Advanced Theranostic Strategies for Viral Hepatitis Using Carbon Nanostructures. MICROMACHINES 2023; 14:1185. [PMID: 37374770 DOI: 10.3390/mi14061185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 05/27/2023] [Accepted: 05/29/2023] [Indexed: 06/29/2023]
Abstract
There are several treatment protocols for acute viral hepatitis, and it is critical to recognize acute hepatitis in its earliest stages. Public health measures to control these infections also rely on rapid and accurate diagnosis. The diagnosis of viral hepatitis remains expensive, and there is no adequate public health infrastructure, while the virus is not well-controlled. New methods for screening and detecting viral hepatitis through nanotechnology are being developed. Nanotechnology significantly reduces the cost of screening. In this review, the potential of three-dimensional-nanostructured carbon substances as promising materials due to fewer side effects, and the contribution of these particles to effective tissue transfer in the treatment and diagnosis of hepatitis due to the importance of rapid diagnosis for successful treatment, were extensively investigated. In recent years, three-dimensional carbon nanomaterials such as graphene oxide and nanotubes with special chemical, electrical, and optical properties have been used for the diagnosis and treatment of hepatitis due to their high potential. We expect that the future position of nanoparticles in the rapid diagnosis and treatment of viral hepatitis can be better determined.
Collapse
Affiliation(s)
- Ahmad Gholami
- Biotechnology Research Center, Shiraz University of Medical Science, Shiraz 71439-14693, Iran
- Pharmaceutical Sciences Research Center, Department of Pharmaceutical Biotechnology, Faculty of Pharmacy, Shiraz University of Medical Science, Shiraz 71439-14693, Iran
| | - Seyyed Mojtaba Mousavi
- Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Reza Masoumzadeh
- Department of Medical, Shiraz University of Medical Sciences, Shiraz 71439-14693, Iran
| | - Mojtaba Binazadeh
- Department of Chemical Engineering, School of Chemical and Petroleum Engineering, Shiraz 71557-13876, Iran
| | - Kamran Bagheri Lankarani
- Health Policy Research Center, Health Institute, Shiraz University of Medical Sciences, Shiraz 71439-14693, Iran
| | - Navid Omidifar
- Biotechnology Research Center, Shiraz University of Medical Science, Shiraz 71439-14693, Iran
- Department of Pathology, Shiraz University of Medical Sciences, Shiraz 71439-14693, Iran
| | - Omid Arjmand
- Department of Chemical Engineering, South Tehran Branch, Islamic Azad University, Tehran 14687-63785, Iran
| | - Wei-Hung Chiang
- Department of Chemical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Mohsen Moghadami
- Non-Communicable Diseases Research Center, Shiraz University of Medical Sciences, Shiraz 71439-14693, Iran
| | - Nelson Pynadathu Rumjit
- Nanotechnology and Catalysis Research Centre (NANOCAT), Level 3, Block A, Institute for Advanced Studies (IAS), University of Malaya (UM), Kuala Lumpur 50603, Malaysia
| |
Collapse
|
4
|
Shimizu M, Hojo M, Ikushima K, Yamamoto Y, Maeno A, Sakamoto Y, Ishimaru N, Taquahashi Y, Kanno J, Hirose A, Suzuki J, Inomata A, Nakae D. Continuous infiltration of small peritoneal macrophages in the mouse peritoneum through CCR2-dependent and -independent routes during fibrosis and mesothelioma development induced by a multiwalled carbon nanotube, MWNT-7. J Toxicol Sci 2023; 48:617-639. [PMID: 38044124 DOI: 10.2131/jts.48.617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
Although toxicities of multiwalled carbon nanotube (MWCNT) have been found to be related with activities of macrophages phagocytosing the fibers, the exact relationship between macrophage population and pathogenesis of fibrosis and mesotheliomas induced by MWCNTs is largely unknown. CCL2-CCR2 axis, a major monocyte/macrophage infiltration route, is thought to be involved in not only acute inflammation but also the formation of tumor microenvironment. We therefore described a time-course of alteration of macrophage population in an attempt to clarify the contribution of the Ccr2 gene to mesotheliomagenesis. Wild-type (WT) C57BL/6 mice and Ccr2-knockout (KO) mice were intraperitoneally administered with MWNT-7 and were sequentially necropsied at 1, 7, 28, 90, and 245 day(s) after the injection. Peritoneal fibrosis was prominent in all MWCNT-treated mice, with a lower severity in the KO mice. No differences were observed in the incidences of neoplastic lesions of mesothelia between WT and KO mice. A flow cytometric analysis revealed that after gross disappearance of macrophages after MWCNT exposure, small peritoneal macrophages (SPMs) were exclusively refurbished by the CCR2-dependent route at day 1 (as Ly-6C+MHC class II- cells), followed by additional CCR2-independent routes (as Ly-6C-MHC class II- cells); i.e., the only route in KO mice; with a delay of 1-7 days. The SPMs derived from both routes appeared to differentiate into maturated cells as Ly-6C-MHC class II+, whose ratio increased in a time-dependent manner among the total SPM population. Additionally, most macrophages expressed M1-like features, but a small fraction of macrophages exhibited an M1/M2 mixed status in MWCNT-treated animals. Our findings demonstrate a long-persistent activation of the CCL2-CCR2 axis after MWCNT exposure and enable a better understanding of the participation and potential roles of SPMs in fibrous material-induced chronic toxicities.
Collapse
Affiliation(s)
- Motomu Shimizu
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Motoki Hojo
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Kiyomi Ikushima
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Yukio Yamamoto
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Ai Maeno
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Yoshimitsu Sakamoto
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Naozumi Ishimaru
- Department of Oral Molecular Pathology, Tokushima University Graduate School of Biomedical Sciences
| | - Yuhji Taquahashi
- Division of Cellular and Molecular Toxicology, Center for Biological Safety and Research, National Institute of Health Sciences
| | - Jun Kanno
- Division of Cellular and Molecular Toxicology, Center for Biological Safety and Research, National Institute of Health Sciences
| | - Akihiko Hirose
- Chemicals Assessment and Research Center, Chemicals Evaluation and Research Institute, Japan
| | - Jin Suzuki
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Akiko Inomata
- Department of Pharmaceutical and Environmental Sciences, Tokyo Metropolitan Institute of Public Health
| | - Dai Nakae
- Department of Medical Sports, Faculty of Health Care and Medical Sports, Teikyo Heisei University
| |
Collapse
|
5
|
Horie M, Sugino S, Ohno T. Follow the time course of inflammation caused by intraperitoneal administration of multi-wall carbon nanotubes in mice. Int J Immunopathol Pharmacol 2023; 37:3946320231176402. [PMID: 37846071 PMCID: PMC10583511 DOI: 10.1177/03946320231176402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Accepted: 04/26/2023] [Indexed: 10/18/2023] Open
Abstract
OBJECTIVE Understand the progress of inflammation over time caused by multi-walled carbon nanotubes (MWCNT). METHODS Two types of MWCNTs were administered to C57BL/6N mice via intraperitoneal administration at low and high doses (0.05 and 1.0 mg/mouse, respectively). Inflammation was evaluated until 6 months after administration based on cytokine levels and pathological observations. The abdominal cavity lavage fluid was collected and analyzed 1 week, 1, 3, and 6 month(s) after administration. IL-6 expression markedly increased 3 months after the administration of high-dose MWCNT-7. RESULTS Notable inflammation was observed in the groups administered with one of the MWCNT, MWCNT-7. On the other hand, inflammation in another MWCNT-treated group was milder than that in the MWCNT-7-treated group. MWCNT-7 induced pronounced inflammation but did not induce tumor formation during the experimental period. Inflammation reaction is one of the most important biological responses to MWCNT. CONCLUSION Three months post-exposure becomes a turning point for the harmful effects of the intraperitoneally administered MWCNT-7.
Collapse
Affiliation(s)
- Masanori Horie
- Health and medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Takamatsu, Japan
| | - Sakiko Sugino
- Health and medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Takamatsu, Japan
| | - Tomoki Ohno
- Health and medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Takamatsu, Japan
| |
Collapse
|
6
|
Salih SJ, Ghobadi MZ. Evaluating the cytotoxicity and pathogenicity of multi-walled carbon nanotube through weighted gene co-expression network analysis: a nanotoxicogenomics study. BMC Genom Data 2022; 23:12. [PMID: 35176998 PMCID: PMC8851761 DOI: 10.1186/s12863-022-01031-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 02/08/2022] [Indexed: 11/20/2022] Open
Abstract
Background Multi-walled carbon nanotube (MWCNT) is one of the most momentous carbonaceous nanoparticles which is widely used for various applications such as electronics, vehicles, and therapeutics. However, their possible toxicity and adverse effects convert them into a major health threat for humans and animals. Results In this study, we employed weighted gene co-expression network analysis (WGCNA) to identify the co-expressed gene groups and dysregulated pathways due to the MWCNT exposure. For this purpose, three weighted gene co-expression networks for the microarray gene expression profiles of the mouse after 1, 6, and 12-month post-exposure to MWCNT were constructed. The module-trait analysis specified the significant modules related to different doses (1, 10, 40, and 80 µg) of MWCNT. Afterward, common genes between co-regulated and differentially expressed genes were determined. The further pathway analysis highlighted the enrichment of genes including Actb, Ube2b, Psme3, Ezh2, Alas2, S100a10, Ypel5, Rhoa, Rac1, Ube2l6, Prdx2, Ctsb, Bnip3l, Gp6, Myh9, Ube2k, Mbnl1, Kbtbd8, Riok3, Itgb1, Rap1a, and Atp5h in immune-, inflammation-, and protein metabolism-related pathways. Conclusions This study discloses the genotoxicity and cytotoxicity effects of various doses of MWCNT which also affect the metabolism system. The identified genes can serve as potential biomarkers and therapeutic candidates. However, further studies should be performed to validate them in human cells. Supplementary Information The online version contains supplementary material available at 10.1186/s12863-022-01031-3.
Collapse
Affiliation(s)
- Shameran Jamal Salih
- Department of Chemistry, Faculty of Science and Health, Koya University, KOY45, Koya, Kurdistan Region, Iraq
| | | |
Collapse
|
7
|
Alberto AR, Matos C, Carmona-Aparicio G, Iten M. Nanomaterials, a New Challenge in the Workplace. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1357:379-402. [DOI: 10.1007/978-3-030-88071-2_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
AbstractNanomaterials are a nanotechnological product of increasing importance given the possibilities they offer to improve quality of life and support sustainable development. Safe management of nanomaterials is needed to ensure that this emerging technology has the highest levels of acceptance among different interest groups, including workers. This chapter reviews the current state that presents the different stages of risk management applied to nanomaterials, including standardisation, regulation, risk assessment and risk control. Particularly, the chapter contextualizes the development of nanotechnologies at European level and analyses the scientific evidence available on the risks derived from nanomaterials use. Furthermore, it highlights the required conditions to encourage the responsible development of nanomaterials, as well as reflects on the lack of consensus in terms of approaches and frameworks that could facilitate standardisation adoption, regulatory enforcement and industry intervention concerning nanomaterials.
Collapse
|
8
|
Fujita K, Obara S, Maru J. Pulmonary toxicity, cytotoxicity, and genotoxicity of submicron-diameter carbon fibers with different diameters and lengths. Toxicology 2021; 466:153063. [PMID: 34890706 DOI: 10.1016/j.tox.2021.153063] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 11/30/2021] [Accepted: 12/06/2021] [Indexed: 12/30/2022]
Abstract
Submicron-diameter carbon fibers (SCFs) are a type of fine-diameter fibrous carbon material that can be used in various applications. To accelerate their practical application, a hazard assessment of SCFs must be undertaken. This study demonstrated the pulmonary toxicity, cytotoxicity, and genotoxicity of three types of SCFs with different diameters and lengths. The average diameter and length of SCFs were 259.2 nm and 11.7 μm in SCF1 suspensions, 248.5 nm and 6.7 μm in SCF2 suspensions, and 183.0 nm and 13.7 μm in SCF3 suspensions, respectively. The results of pulmonary inflammation and recovery following intratracheal instillation with SCFs at doses of 0.25, 0.5, or 1.0 mg/kg showed that the pulmonary toxicity of SCFs was SCF3 > SCF1 > SCF2. These results suggest that SCF diameter and length are most likely important contributing factors associated with lung SCF clearance, pulmonary inflammation, and recovery. Furthermore, SCFs are less pulmonary toxic than bent multi-walled carbon nanotubes. Cell viability, pro-inflammatory cytokine and intracellular reactive oxygen species productions, morphological changes, gene expression profiling in NR8383 rat alveolar macrophage cells showed that the cytotoxic potency of SCFs is: SCF3 > SCF1 > SCF2. These results showed that SCFs with small diameters had high cytotoxicity, and SCFs with short lengths had low cytotoxicity. We conclude that pulmonary toxicity and cytotoxicity are associated with the diameter and length distributions of SCFs. In addition, a standard battery for genotoxicity testing, namely the Ames test, an in vitro chromosomal aberration test, and a mammalian erythrocyte micronucleus test, demonstrated that the three types of SCFs did not induce genotoxicity. Our findings provide new evidence for evaluating the potential toxicity of not only SCFs used in this study but also various SCFs which differ depending on the manufacturing processes or physicochemical properties.
Collapse
Affiliation(s)
- Katsuhide Fujita
- Research Institute of Science for Safety and Sustainability (RISS), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, 305-8569, Japan.
| | - Sawae Obara
- Research Institute of Science for Safety and Sustainability (RISS), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, 305-8569, Japan
| | - Junko Maru
- Research Institute of Science for Safety and Sustainability (RISS), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, 305-8569, Japan
| |
Collapse
|
9
|
Cosnier F, Seidel C, Valentino S, Schmid O, Bau S, Vogel U, Devoy J, Gaté L. Retained particle surface area dose drives inflammation in rat lungs following acute, subacute, and subchronic inhalation of nanomaterials. Part Fibre Toxicol 2021; 18:29. [PMID: 34353337 PMCID: PMC8340536 DOI: 10.1186/s12989-021-00419-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Accepted: 06/23/2021] [Indexed: 01/05/2023] Open
Abstract
Background An important aspect of nanomaterial (NM) risk assessment is establishing relationships between physicochemical properties and key events governing the toxicological pathway leading to adverse outcomes. The difficulty of NM grouping can be simplified if the most toxicologically relevant dose metric is used to assess the toxicological dose-response. Here, we thoroughly investigated the relationship between acute and chronic inflammation (based on polymorphonuclear neutrophil influx (% PMN) in lung bronchoalveolar lavage) and the retained surface area in the lung. Inhalation studies were performed in rats with three classes of NMs: titanium dioxides (TiO2) and carbon blacks (CB) as poorly soluble particles of low toxicity (PSLT), and multiwall carbon nanotubes (MWCNTs). We compared our results to published data from nearly 30 rigorously selected articles. Results This analysis combined data specially generated for this work on three benchmark materials - TiO2 P25, the CB Printex-90 and the MWCNT MWNT-7 - following subacute (4-week) inhalation with published data relating to acute (1-week) to subchronic (13-week) inhalation exposure to the classes of NMs considered. Short and long post-exposure recovery times (immediately after exposure up to more than 6 months) allowed us to examine both acute and chronic inflammation. A dose-response relationship across short-term and long-term studies was revealed linking pulmonary retained surface area dose (measured or estimated) and % PMN. This relationship takes the form of sigmoid curves, and is independent of the post-exposure time. Curve fitting equations depended on the class of NM considered, and sometimes on the duration of exposure. Based on retained surface area, long and thick MWCNTs (few hundred nm long with an aspect ratio greater than 25) had a higher inflammatory potency with 5 cm2/g lung sufficient to trigger an inflammatory response (at 6% PMN), whereas retained surfaces greater than 150 cm2/g lung were required for PSLT. Conclusions Retained surface area is a useful metric for hazard grouping purposes. This metric would apply to both micrometric and nanometric materials, and could obviate the need for direct measurement in the lung. Indeed, it could alternatively be estimated from dosimetry models using the aerosol parameters (rigorously determined following a well-defined aerosol characterization strategy). Supplementary Information The online version contains supplementary material available at 10.1186/s12989-021-00419-w.
Collapse
Affiliation(s)
- Frédéric Cosnier
- Institut National de Recherche et de Sécurité, 1 Rue du Morvan, CS 60027, 54519, Vandœuvre-les-Nancy Cedex, France.
| | - Carole Seidel
- Institut National de Recherche et de Sécurité, 1 Rue du Morvan, CS 60027, 54519, Vandœuvre-les-Nancy Cedex, France
| | - Sarah Valentino
- Institut National de Recherche et de Sécurité, 1 Rue du Morvan, CS 60027, 54519, Vandœuvre-les-Nancy Cedex, France
| | - Otmar Schmid
- Institute of Lung Biology and Disease, Helmholtz Zentrum München, 85764, Neuherberg, Germany.,Comprehensive Pneumology Center, Munich (CPC-M) - Member of the German Center for Lung Research (DZL), 81377, Munich, Germany
| | - Sébastien Bau
- Institut National de Recherche et de Sécurité, 1 Rue du Morvan, CS 60027, 54519, Vandœuvre-les-Nancy Cedex, France
| | - Ulla Vogel
- National Research Centre for the Working Environment, Lersø Parkallé 105, DK-2100, Copenhagen, Denmark.,Department of Health Technology by DTU Food, Technical University of Denmark, DK-2800, Kgs. Lyngby, Denmark
| | - Jérôme Devoy
- Institut National de Recherche et de Sécurité, 1 Rue du Morvan, CS 60027, 54519, Vandœuvre-les-Nancy Cedex, France
| | - Laurent Gaté
- Institut National de Recherche et de Sécurité, 1 Rue du Morvan, CS 60027, 54519, Vandœuvre-les-Nancy Cedex, France
| |
Collapse
|
10
|
Occupational Exposure to Carbon Nanotubes and Carbon Nanofibres: More Than a Cobweb. NANOMATERIALS 2021; 11:nano11030745. [PMID: 33809629 PMCID: PMC8002294 DOI: 10.3390/nano11030745] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 03/11/2021] [Accepted: 03/13/2021] [Indexed: 01/20/2023]
Abstract
Carbon nanotubes (CNTs) and carbon nanofibers (CNFs) are erroneously considered as singular material entities. Instead, they should be regarded as a heterogeneous class of materials bearing different properties eliciting particular biological outcomes both in vitro and in vivo. Given the pace at which the industrial production of CNTs/CNFs is increasing, it is becoming of utmost importance to acquire comprehensive knowledge regarding their biological activity and their hazardous effects in humans. Animal studies carried out by inhalation showed that some CNTs/CNFs species can cause deleterious effects such as inflammation and lung tissue remodeling. Their physico-chemical properties, biological behavior and biopersistence make them similar to asbestos fibers. Human studies suggest some mild effects in workers handling CNTs/CNFs. However, owing to their cross-sectional design, researchers have been as yet unable to firmly demonstrate a causal relationship between such an exposure and the observed effects. Estimation of acceptable exposure levels should warrant a proper risk management. The aim of this review is to challenge the conception of CNTs/CNFs as a single, unified material entity and prompt the establishment of standardized hazard and exposure assessment methodologies able to properly feed risk assessment and management frameworks.
Collapse
|
11
|
Rau JV, Fosca M, Fadeeva IV, Kalay S, Culha M, Raucci MG, Fasolino I, Ambrosio L, Antoniac IV, Uskoković V. Tricalcium phosphate cement supplemented with boron nitride nanotubes with enhanced biological properties. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 114:111044. [DOI: 10.1016/j.msec.2020.111044] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Revised: 04/26/2020] [Accepted: 04/30/2020] [Indexed: 11/26/2022]
|
12
|
Kondej D, Sosnowski TR. Interfacial rheology for the assessment of potential health effects of inhaled carbon nanomaterials at variable breathing conditions. Sci Rep 2020; 10:14044. [PMID: 32820205 PMCID: PMC7441146 DOI: 10.1038/s41598-020-70909-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Accepted: 07/27/2020] [Indexed: 01/01/2023] Open
Abstract
Lung surface is the first line of contact between inhaled carbon nanomaterials, CNMs, and the organism, so this is the place where pulmonary health effects begin. The paper analyzes the influence of several CNMs (single- and multi-walled nanotubes with various surface area: 90-1,280 m2/g and aspect ratio: 8-3,750) on the surface-active properties of the lung surfactant, LS, model (Survanta). Effects of CNM concentration (0.1-1 mg/ml) and surface oscillation rate were determined using the oscillating drop method at simulated breathing conditions (2-10 s per cycle, 37 °C). Based on the values of apparent elasticity and viscosity of the interfacial region, new parameters: Sε and Sμ were proposed to evaluate potential effect of particles on the LS at various breathing rates. Some of tested CNMs (e.g., COOH- functionalized short nanotubes) significantly influenced the surfactant dynamics, while the other had weaker effects even at high particle concentration. Analysis of changes in Sε and Sμ provides a new way to evaluate of a possible disturbance of the basic functions of LS. The results show that the expected pulmonary effects caused by inhaled CNMs at variable breathing rate depend not only on particle concentration (inhaled dose) but also on their size, structure and surface properties.
Collapse
Affiliation(s)
- Dorota Kondej
- Central Institute for Labour Protection - National Research Institute, Czerniakowska 16, 00-701, Warsaw, Poland
| | - Tomasz R Sosnowski
- Faculty of Chemical and Process Engineering, Warsaw University of Technology, Waryńskiego 1, 00-645, Warsaw, Poland.
| |
Collapse
|
13
|
Di Ianni E, Møller P, Mortensen A, Szarek J, Clausen PA, Saber AT, Vogel U, Jacobsen NR. Organomodified nanoclays induce less inflammation, acute phase response, and genotoxicity than pristine nanoclays in mice lungs. Nanotoxicology 2020; 14:869-892. [PMID: 32536294 DOI: 10.1080/17435390.2020.1771786] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Surface modification by different quaternary ammonium compounds (QAC) makes nanoclays more compatible with various polymeric matrices, thereby expanding their potential applications. The growing industrial use of nanoclays could potentially pose a health risk for workers. Here, we assessed how surface modification of nanoclays modulates their pulmonary toxicity. An in vitro screening of the unmodified nanoclay Bentonite (montmorillonite) and four organomodified nanoclays (ONC); coated with various QAC, including benzalkonium chloride (BAC), guided the selection of the materials for the in vivo study. Mice were exposed via a single intratracheal instillation to 18, 54, and 162 µg of unmodified Bentonite or dialkyldimethyl-ammonium-coated ONC (NanofilSE3000), or to 6, 18, and 54 µg of a BAC-coated ONC (Nanofil9), and followed for one, 3, or 28 days. All materials induced dose- and time-dependent responses in the exposed mice. However, all doses of Bentonite induced larger, but reversible, inflammation (BAL neutrophils) and acute phase response (Saa3 gene expression in lung) than the two ONC. Similarly, highest levels of DNA strand breaks were found in BAL cells of mice exposed to Bentonite 1 day post-exposure. A significant increase of DNA strand breaks was detected also for NanofilSE3000, 3 days post-exposure. Only mice exposed to Bentonite showed increased Tgf-β gene expression in lung, biomarker of pro-fibrotic processes and hepatic extravasation, 3 days post-exposure. This study indicates that Bentonite treatment with some QAC changes main physical-chemical properties, including shape and surface area, and may decrease their pulmonary toxicity in exposed mice.
Collapse
Affiliation(s)
- Emilio Di Ianni
- National Research Centre for the Working Environment, Copenhagen, Denmark
| | - Peter Møller
- Department of Public Health, University of Copenhagen, Copenhagen, Denmark
| | - Alicja Mortensen
- National Research Centre for the Working Environment, Copenhagen, Denmark
| | - Józef Szarek
- Department of Pathophysiology, Forensic Veterinary Medicine and Administration, University of Warmia and Mazury in Olsztyn, Olsztyn, Poland
| | - Per Axel Clausen
- National Research Centre for the Working Environment, Copenhagen, Denmark
| | | | - Ulla Vogel
- National Research Centre for the Working Environment, Copenhagen, Denmark.,Department of Micro- and Nanotechnology, DTU, Lyngby, Denmark
| | | |
Collapse
|
14
|
O’Shaughnessy P, Stoltenberg A, Holder C, Altmaier R. Laboratory evaluation of a personal aethalometer for assessing airborne carbon nanotube exposures. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2020; 17:262-273. [PMID: 32286917 PMCID: PMC7282999 DOI: 10.1080/15459624.2020.1740237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Aethalometers are direct-reading instruments primarily used for measuring black carbon (BC) concentrations in workplace and ambient atmospheres. Aethalometer BC measurements of carbon nanotubes (CNTs) were compared to measurements made by other methods when subjected to high (>30 µg/m3) and low (1-30 µg/m3) CNT aerosol concentrations representing worst-case and typical workplace concentrations, respectively. A laboratory-based system was developed to generate carbon black, as an example of a nearly pure carbon, micron-sized aerosol, and two forms of multi-walled carbon nanotubes (CNTs): small-diameter (<8 nm) and large-diameter (50-80 nm). High-concentration trials were conducted during which a scanning mobility particle sizer (SMPS) was used to track particle count concentrations over time. Relative to the behavior of the SMPS counts over time, aethalometer readings exhibited a downward drift, which is indicative of aethalometer response subjected to high BC loading on the receiving filter of the instrument. A post-sample mathematical method was applied that adequately corrected for the drift. Low-concentration trials, during which concentration drift did not occur, were conducted to test aethalometer accuracy. The average BC concentration during a trial was compared to elemental carbon (EC) concentration sampled with a quartz-fiber filter and quantified by NIOSH Method 5040. The CB and large-diameter CNT concentrations measured with the aethalometer produced slopes when regressed on EC that were not significantly different from unity, whereas the small-diameter CNTs were under-sampled by the aethalometer relative to EC. These results indicate that aethalometer response may drift when evaluating CNT exposure scenarios, such as cleaning and powder handling, that produce concentrations >30 µg/m3. However, aethalometer accuracy remains consistent over time when sampling general work zones in which CNT concentrations are expected to be <30 µg/m3. A calibration check of aethalometer response relative to EC measured with Method 5040 is recommended to ensure that the aethalometer readings are not under sampling CNT concentrations as occurred with one of the CNTs evaluated in this study.
Collapse
Affiliation(s)
- Patrick O’Shaughnessy
- Department of Occupational and Environmental Health, College of Public Health, 100 CPHB, S320, The University of Iowa, Iowa City, Iowa
| | - Adrianne Stoltenberg
- Department of Occupational and Environmental Health, College of Public Health, 100 CPHB, S320, The University of Iowa, Iowa City, Iowa
| | - Craig Holder
- Department of Occupational and Environmental Health, College of Public Health, 100 CPHB, S320, The University of Iowa, Iowa City, Iowa
| | - Ralph Altmaier
- Department of Occupational and Environmental Health, College of Public Health, 100 CPHB, S320, The University of Iowa, Iowa City, Iowa
| |
Collapse
|
15
|
Barfod KK, Bendtsen KM, Berthing T, Koivisto AJ, Poulsen SS, Segal E, Verleysen E, Mast J, Holländer A, Jensen KA, Hougaard KS, Vogel U. Increased surface area of halloysite nanotubes due to surface modification predicts lung inflammation and acute phase response after pulmonary exposure in mice. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY 2020; 73:103266. [PMID: 31707308 DOI: 10.1016/j.etap.2019.103266] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 09/14/2019] [Accepted: 09/17/2019] [Indexed: 06/10/2023]
Abstract
The toxicological potential of halloysite nanotubes (HNTs) and variants after functional alterations to surface area are not clear. We assessed the toxicological response to HNTs (NaturalNano (NN)) before and after surface etching (NN-etched). Potential cytotoxicity of the two HNTs was screened in vitro in MutaTMMouse lung epithelial cells. Lung inflammation, acute phase response and genotoxicity were assessed 1, 3, and 28 days after a single intratracheal instillation of adult female C57BL/6 J BomTac mice. The doses were 6, 18 or 54 μg of HNTs, compared to vehicle controls and the Carbon black NP (Printex 90) of 162 μg/mouse. The cellular composition of bronchoalveolar lavage (BAL) fluid was determined as a measure of lung inflammation. The pulmonary and hepatic acute phase responses were assessed by Serumamyloida mRNA levels in lung and liver tissue by real-time quantitative PCR. Pulmonary and systemic genotoxicity were analyzed by the alkaline comet assay as DNA strand breaks in BAL cells, lung and liver tissue. The etched HNT (NN-etched) had 4-5 times larger BET surface area than the unmodified HNT (NN). Instillation of NN-etched at the highest dose induced influx of neutrophils into the lungs at all time points and increased Saa3 mRNA levels in lung tissue on day 1 and 3 after exposure. No genotoxicity was observed at any time point. In conclusion, functionalization by etching increased BET surface area of the studied NN and enhanced pulmonary inflammatory toxicity in mice.
Collapse
Affiliation(s)
- Kenneth Klingenberg Barfod
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark; Department of Veterinary and Animal Sciences, University of Copenhagen, Copenhagen, DK-1014, Denmark
| | - Katja Maria Bendtsen
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark
| | - Trine Berthing
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark
| | - Antti Joonas Koivisto
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark
| | - Sarah Søs Poulsen
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark
| | - Ester Segal
- Department of Biotechnology and Food Engineering, Technion - Israel Institute of Technology, Haifa, 32000, Israel
| | | | - Jan Mast
- Sciensano, Groeselenbergstraat 99, 1180, Uccle, Belgium
| | - Andreas Holländer
- Fraunhofer-Institut für Angewandte Polymerforschung, Geiselbergstr. 69, 14476, Potsdam, Germany
| | - Keld Alstrup Jensen
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark
| | - Karin Sørig Hougaard
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark; Department of Public Health, University of Copenhagen, Copenhagen, DK-1014, Denmark
| | - Ulla Vogel
- National Research Centre for the Working Environment, Lersø Parkallé 105, Copenhagen, DK-2100, Denmark; DTU Health Tech, Technical University of Denmark, Kgs. Lyngby, DK-2800, Denmark.
| |
Collapse
|
16
|
Kiratipaiboon C, Stueckle TA, Ghosh R, Rojanasakul LW, Chen YC, Dinu CZ, Rojanasakul Y. Acquisition of Cancer Stem Cell-like Properties in Human Small Airway Epithelial Cells after a Long-term Exposure to Carbon Nanomaterials. ENVIRONMENTAL SCIENCE. NANO 2019; 6:2152-2170. [PMID: 31372228 PMCID: PMC6675031 DOI: 10.1039/c9en00183b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Cancer stem cells (CSCs) are a key driver of tumor formation and metastasis, but how they are affected by nanomaterials is largely unknown. The present study investigated the effects of different carbon-based nanomaterials (CNMs) on neoplastic and CSC-like transformation of human small airway epithelial cells and determined the underlying mechanisms. Using a physiologically relevant exposure model (long-term/low-dose) with system validation using a human carcinogen, asbestos, we demonstrated that single-walled carbon nanotubes, multi-walled carbon nanotubes, ultrafine carbon black, and crocidolite asbestos induced particle-specific anchorage-independent colony formation, DNA-strand break, and p53 downregulation, indicating genotoxicity and carcinogenic potential of CNMs. The chronic CNM-exposed cells exhibited CSC-like properties as indicated by 3D spheroid formation, anoikis resistance, and CSC markers expression. Mechanistic studies revealed specific self-renewal and epithelial-mesenchymal transition (EMT)-related transcription factors that are involved in the cellular transformation process. Pathway analysis of gene signaling networks supports the role of SOX2 and SNAI1 signaling in CNM-mediated transformation. These findings support the potential carcinogenicity of high aspect ratio CNMs and identified molecular targets and signaling pathways that may contribute to the disease development.
Collapse
Affiliation(s)
- Chayanin Kiratipaiboon
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, West Virginia, 26506, United States
| | - Todd A Stueckle
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia, 26505, United States
| | - Rajib Ghosh
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, West Virginia, 26506, United States
| | - Liying W Rojanasakul
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia, 26505, United States
| | - Yi Charlie Chen
- College of Science, Technology and Mathematics, Alderson Broaddus University, Philippi, West Virginia, 26416, United States
| | - Cerasela Zoica Dinu
- Department of Chemical Engineering, West Virginia University, Morgantown, West Virginia, 26506, United States
| | - Yon Rojanasakul
- Department of Pharmaceutical Sciences and WVU Cancer Institute, West Virginia University, Morgantown, West Virginia, 26506, United States
| |
Collapse
|
17
|
Stuttgen V, Giffney HE, Anandan A, Alabdali A, Twarog C, Belhout SA, O Loughlin M, Podhorska L, Delaney C, Geoghegan N, Mc-Fadden J, Alhadhrami NA, Fleming A, Phadke S, Yadav R, Fattah S, McCartney F, Alsharif SA, McCaul J, Singh K, Erikandath S, O Meara F, Wychowaniec JK, Cutrona MB, MacMaster G, Reynolds AL, Gaines S, Hogg B, Farrelly M, D Alton M, Coulahan P, Bhattacharjee S. The UCD nanosafety workshop (03 December 2018): towards developing a consensus on safe handling of nanomaterials within the Irish university labs and beyond - a report. Nanotoxicology 2019; 13:717-732. [PMID: 31111769 DOI: 10.1080/17435390.2019.1621402] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Careful handling of the nanomaterials (NMs) in research labs is crucial to ensure a safe working environment. As the largest university in Ireland, University College Dublin (UCD) has invested significant resources to update researchers working with NMs. Due to sizes often <100 nm, the NMs including nanoparticles, harbor unprecedented materialistic properties, for example, enhanced reactivity, conductivity, fluorescence, etc. which albeit conferring the NMs an edge over bulk materials regarding the applied aspects; depending on the dose, also render them to be toxic. Thus, a set of regulatory guidelines have emerged regarding safe handling of the NMs within occupational set-ups. Unfortunately, the current regulations based on the toxic chemicals and carcinogens are often confusing, lack clarity, and difficult to apply for the NMs. As a research-intensive university, a diverse range of research activities occur within the UCD labs, and it is difficult, at times impossible, for the UCD Safety, Insurance, Operational Risk & Compliance (SIRC) office to develop a set of common guidelines and cater throughout all its labs conducting research with the NMs. Hence, a necessity for dialog and exchange of ideas was felt across the UCD which encouraged the researchers including early stage researchers (e.g. PhDs, Postdocs) from multiple schools to participate in a workshop held on the 03 December 2018. The workshop tried to follow a pragmatic approach, where apart from discussing both the in vitro and in vivo scenarios, practical cases simulating situations faced frequently in the labs were discussed. This report summarizes the findings made during the workshop by this emerging critical mass in UCD.
Collapse
Affiliation(s)
- Vivien Stuttgen
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Hugh E Giffney
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Ayana Anandan
- b School of Biology and Environmental Science (SBES) , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Anwar Alabdali
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Caroline Twarog
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Samir A Belhout
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Mark O Loughlin
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Lucia Podhorska
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Colm Delaney
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Niamh Geoghegan
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Jessica Mc-Fadden
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Nahlah A Alhadhrami
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Aisling Fleming
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Shreyas Phadke
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Ravi Yadav
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Sarinj Fattah
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Fiona McCartney
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Shada Ali Alsharif
- d School of Physics , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Jasmin McCaul
- e School of Biomolecular and Biomedical Science (SBBS) , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Krutika Singh
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Sumesh Erikandath
- d School of Physics , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Fergal O Meara
- e School of Biomolecular and Biomedical Science (SBBS) , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Jacek K Wychowaniec
- c School of Chemistry , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Meritxell B Cutrona
- b School of Biology and Environmental Science (SBES) , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Gwyneth MacMaster
- b School of Biology and Environmental Science (SBES) , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Alison L Reynolds
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Susan Gaines
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Bridget Hogg
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Marc Farrelly
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Mark D Alton
- f Biomedical Facilities , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Peter Coulahan
- g Safety, Insurance, Operational Risk & Compliance (SIRC) Office , University College Dublin (UCD) , Belfield , Dublin , Ireland
| | - Sourav Bhattacharjee
- a School of Veterinary Medicine , University College Dublin (UCD) , Belfield , Dublin , Ireland
| |
Collapse
|
18
|
Suganuma N, Natori Y, Kurosawa H, Nakano M, Kasai T, Morimoto Y. Update of occupational lung disease. J Occup Health 2019; 61:10-18. [PMID: 30698346 PMCID: PMC6499361 DOI: 10.1002/1348-9585.12031] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 09/01/2018] [Accepted: 09/20/2018] [Indexed: 01/06/2023] Open
Abstract
Objective Occupational Lung Disease is an oldest but still a biggest problem in occupational health. Methods Steering Committee members of the Japan Society for Occupational Health (JSOH) Occupational Lung Disease Study Group selected and summarized current topics on occupational lung diseases based on expert opinion, as informed by governmental regulation, public health concerns, and frequently discussed in related academic conferences. Results The topics included in this review are professional education in medical screening skills, 2014 update of Helsinki Criteria, respiratory diseases found in the earthquake and tsunami affected regions, newly recognized occupational lung diseases, and potential respiratory health hazards. Discussions Although occupational lung diseases seem to stay as one of the major concerns in occupational health, screening tools and control measures are standardized for the better prevention of the diseases. As this health problem usually occurs in where the most actively economically developing area is, the patients tend to increase in emerging economic powers with huge population.
Collapse
Affiliation(s)
- Narufumi Suganuma
- Japan Society for Occupational Health (JSOH) Occupational Lung Disease Study Group, Tokya, Japan.,Department of Environmental Medicine, Kochi Medical School, Kochi Univeristy, Nankoku, Japan
| | - Yuji Natori
- Japan Society for Occupational Health (JSOH) Occupational Lung Disease Study Group, Tokya, Japan.,Hirano-Kameido Himawari-Clinic, Koto-ku, Japan
| | - Hajime Kurosawa
- Japan Society for Occupational Health (JSOH) Occupational Lung Disease Study Group, Tokya, Japan.,Department of Occupational Health, Tohoku University School of Medicine, Sendai, Japan
| | - Makiko Nakano
- Japan Society for Occupational Health (JSOH) Occupational Lung Disease Study Group, Tokya, Japan.,Department of Preventive Medicine and Public Health, Keio University School of Medicine, Shinjuku, Japan
| | - Takahiko Kasai
- Japan Society for Occupational Health (JSOH) Occupational Lung Disease Study Group, Tokya, Japan.,Department of Pathology, Kinki-Chuo Chest Medical Center, Sakai, Japan
| | - Yasuo Morimoto
- Japan Society for Occupational Health (JSOH) Occupational Lung Disease Study Group, Tokya, Japan.,University of Occupational and Environmental Health, Japan, Kitakyushu, Japan
| | | |
Collapse
|
19
|
Pastrana HF, Cartagena-Rivera AX, Raman A, Ávila A. Evaluation of the elastic Young's modulus and cytotoxicity variations in fibroblasts exposed to carbon-based nanomaterials. J Nanobiotechnology 2019; 17:32. [PMID: 30797235 PMCID: PMC6387485 DOI: 10.1186/s12951-019-0460-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Accepted: 01/22/2019] [Indexed: 12/30/2022] Open
Abstract
Background The conventional approaches to assess the potential cytotoxic effects of nanomaterials (NMs) mainly rely on in vitro biochemical assays. These assays are strongly dependent on the properties of the nanomaterials, for example; specific surface area (SSA), size, surface defects, and surface charge, and the host response. The NMs properties can also interfere with the reagents of the biochemical and optical assays leading to skewed interpretations and ambiguous results related to the NMs toxicity. Here, we proposed a structured approach for cytotoxicity assessment complemented with cells’ mechanical responses represented as the variations of elastic Young’s modulus in conjunction with conventional biochemical tests. Monitoring the mechanical properties responses at various times allowed understanding the effects of NMs to the filamentous actin cytoskeleton. The elastic Young’s modulus was estimated from the force volume maps using an atomic force microscope (AFM). Results Our results show a significant decrease on Young’s modulus, ~ 20%, in cells exposed to low concentrations of graphene flakes (GF), ~ 10% decrease for cells exposed to low concentrations of multiwalled carbon nanotubes (MWCNTs) than the control cells. These considerable changes were directly correlated to the disruption of the cytoskeleton actin fibers. The length of the actin fibers in cells exposed to GF was 50% shorter than the fibers of the cells exposed to MWCNT. Applying both conventional biochemical approach and cells mechanics, we were able to detect differences in the actin networks induced by MWCNT inside the cells and GF outside the cell’s membrane. These results contrast with the conventional live/dead assay where we obtained viabilities greater than 80% after 24 h; while the elasticity dramatically decreased suggesting a fast-metabolic stress generation. Conclusions We confirmed the production of radical oxygen species (ROS) on cells exposed to CBNs, which is related to the disruption of the cytoskeleton. Altogether, the changes in mechanical properties and the length of F-actin fibers confirmed that disruption of the F-actin cytoskeleton is a major consequence of cellular toxicity. We evidenced the importance of not just nanomaterials properties but also the effect of the location to assess the cytotoxic effects of nanomaterials. Electronic supplementary material The online version of this article (10.1186/s12951-019-0460-8) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Homero F Pastrana
- Departamento de Ingeniería Eléctrica y Electrónica, Universidad de Los Andes, Bogotá D.C., Colombia.,Centro de Microelectrónica, Universidad de los Andes (CMUA), Bogotá D.C, Colombia.,Birck Nanotechnology Center, Purdue University, West Lafayette, IN, USA
| | - Alexander X Cartagena-Rivera
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA.,Birck Nanotechnology Center, Purdue University, West Lafayette, IN, USA.,Section on Auditory Mechanics, National Institute on Deafness and Other Communication Disorders (NIDCD), National Institutes of Health (NIH), Bethesda, MD, USA
| | - Arvind Raman
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, USA
| | - Alba Ávila
- Departamento de Ingeniería Eléctrica y Electrónica, Universidad de Los Andes, Bogotá D.C., Colombia. .,Centro de Microelectrónica, Universidad de los Andes (CMUA), Bogotá D.C, Colombia.
| |
Collapse
|
20
|
Schulte PA, Kuempel ED, Drew NM. Characterizing risk assessments for the development of occupational exposure limits for engineered nanomaterials. Regul Toxicol Pharmacol 2018; 95:207-219. [PMID: 29574195 PMCID: PMC6075708 DOI: 10.1016/j.yrtph.2018.03.018] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 03/05/2018] [Accepted: 03/20/2018] [Indexed: 12/16/2022]
Abstract
The commercialization of engineered nanomaterials (ENMs) began in the early 2000's. Since then the number of commercial products and the number of workers potentially exposed to ENMs is growing, as is the need to evaluate and manage the potential health risks. Occupational exposure limits (OELs) have been developed for some of the first generation of ENMs. These OELs have been based on risk assessments that progressed from qualitative to quantitative as nanotoxicology data became available. In this paper, that progression is characterized. It traces OEL development through the qualitative approach of general groups of ENMs based primarily on read-across with other materials to quantitative risk assessments for nanoscale particles including titanium dioxide, carbon nanotubes and nanofibers, silver nanoparticles, and cellulose nanocrystals. These represent prototypic approaches to risk assessment and OEL development for ENMs. Such substance-by-substance efforts are not practical given the insufficient data for many ENMs that are currently being used or potentially entering commerce. Consequently, categorical approaches are emerging to group and rank ENMs by hazard and potential health risk. The strengths and limitations of these approaches are described, and future derivations and research needs are discussed. Critical needs in moving forward with understanding the health effects of the numerous EMNs include more standardized and accessible quantitative data on the toxicity and physicochemical properties of ENMs.
Collapse
Affiliation(s)
- P A Schulte
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, United States.
| | - E D Kuempel
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, United States
| | - N M Drew
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, United States
| |
Collapse
|
21
|
Fukushima S, Kasai T, Umeda Y, Ohnishi M, Sasaki T, Matsumoto M. Carcinogenicity of multi-walled carbon nanotubes: challenging issue on hazard assessment. J Occup Health 2018; 60:10-30. [PMID: 29046510 PMCID: PMC5799097 DOI: 10.1539/joh.17-0102-ra] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Accepted: 09/10/2017] [Indexed: 01/20/2023] Open
Abstract
OBJECTIVES This report reviews the carcinogenicity of multi-walled carbon nanotubes (MWCNTs) in experimental animals, concentrating on MWNT-7, a straight fibrous MWCNT. METHODS MWCNTs were administered to mice and rats by intraperitoneal injection, intrascrotal injection, subcutaneous injection, intratracheal instillation and inhalation. RESULTS Intraperitoneal injection of MWNT-7 induced peritoneal mesothelioma in mice and rats. Intrascrotal injection induced peritoneal mesothelioma in rats. Intratracheal instillation of MWCNT-N (another straight fibrous MWCNT) induced both lung carcinoma and pleural mesothelioma in rats. In the whole body inhalation studies, in mice MWNT-7 promoted methylcholanthrene-initiated lung carcinogenesis. In rats, inhalation of MWNT-7 induced lung carcinoma and lung burdens of MWNT-7 increased with increasing concentration of airborne MWNT-7 and increasing duration of exposure. CONCLUSIONS Straight, fibrous MWCNTs exerted carcinogenicity in experimental animals. Phagocytosis of MWCNT fibers by macrophages was very likely to be a principle factor in MWCNT lung carcinogenesis. Using no-observed-adverse-effect level-based approach, we calculated that the occupational exposure limit (OEL) of MWNT-7 for cancer protection is 0.15 μg/m3 for a human worker. Further studies on the effects of the shape and size of MWCNT fibers and mode of action on the carcinogenicity are required.
Collapse
Affiliation(s)
- Shoji Fukushima
- Japan Bioassay Research Center, Japan Organization of Occupational Health and Safety
- Association for Promotion of Research on Risk Assessment
| | - Tatsuya Kasai
- Japan Bioassay Research Center, Japan Organization of Occupational Health and Safety
| | - Yumi Umeda
- Japan Bioassay Research Center, Japan Organization of Occupational Health and Safety
| | - Makoto Ohnishi
- Japan Bioassay Research Center, Japan Organization of Occupational Health and Safety
| | - Toshiaki Sasaki
- Japan Bioassay Research Center, Japan Organization of Occupational Health and Safety
| | - Michiharu Matsumoto
- Japan Bioassay Research Center, Japan Organization of Occupational Health and Safety
| |
Collapse
|
22
|
Honda K, Naya M, Takehara H, Kataura H, Fujita K, Ema M. A 104-week pulmonary toxicity assessment of long and short single-wall carbon nanotubes after a single intratracheal instillation in rats. Inhal Toxicol 2017; 29:471-482. [PMID: 29110549 DOI: 10.1080/08958378.2017.1394930] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
We compared long-term pulmonary toxicities after a single intratracheal instillation of two types of dispersed single-wall carbon nanotubes (SWCNTs), namely, those with relatively long or short linear shapes with average lengths of 8.6 and 0.55 µm, respectively. Both types of SWCNTs were instilled intratracheally in male F344 rats at 0.2 or 1.0 mg/kg (long SWCNTs) or 1.0 mg/kg (short SWCNTs). Pulmonary responses were characterized at 26, 52 and 104 weeks after a single instillation. Inflammatory changes, test substance deposition, test substance engulfment by macrophages, and alveolar wall fibrosis were observed in the lungs of almost all test rats at 52 and 104 weeks after short nanotube instillation. The incidences of these changes were much lower in the long nanotube-treated groups. In almost all rats of the long nanotube-treated groups, fibrosis and epithelium loss in the terminal bronchiole with test substance deposition were observed. These bronchiolar changes were not observed after administering short nanotubes. Both bronchiolo-alveolar adenoma and carcinoma were found in the negative-control group, the high-dose long-nanotube group, and the short-nanotube group at 104 weeks post-instillation, although the incidences were not statistically different. The genotoxicity of the SWCNTs was also evaluated by performing in vivo comet assays with lung cells obtained 26 weeks post-instillation. No significant changes in the percent tail deoxyribonucleic acid were found in any group. These findings suggested that most long SWCNTs were deposited at the terminal bronchioles and that a considerable amount of short SWCNTs reached the alveolus, resulting in chronic inflammatory responses, but no genotoxicity in the lungs.
Collapse
Affiliation(s)
- Kazumasa Honda
- a Research Institute of Science for Safety and Sustainability , National Institute of Advanced Industrial Science and Technology (AIST) , Tsukuba , Japan.,b Technology Research Association for Single Wall Carbon Nanotubes (TASC) , Tsukuba , Japan
| | - Masato Naya
- a Research Institute of Science for Safety and Sustainability , National Institute of Advanced Industrial Science and Technology (AIST) , Tsukuba , Japan
| | - Hiroshi Takehara
- c Public Interest Incorporated Foundation, BioSafety Research Center (BSRC) , Iwata , Japan
| | - Hiromichi Kataura
- d Nanomaterials Research Institute , National Institute of Advanced Industrial Science and Technology (AIST) , Tsukuba , Japan
| | - Katsuhide Fujita
- a Research Institute of Science for Safety and Sustainability , National Institute of Advanced Industrial Science and Technology (AIST) , Tsukuba , Japan.,b Technology Research Association for Single Wall Carbon Nanotubes (TASC) , Tsukuba , Japan
| | - Makoto Ema
- a Research Institute of Science for Safety and Sustainability , National Institute of Advanced Industrial Science and Technology (AIST) , Tsukuba , Japan.,b Technology Research Association for Single Wall Carbon Nanotubes (TASC) , Tsukuba , Japan
| |
Collapse
|
23
|
Catalán J, Stockmann-Juvala H, Norppa H. A theoretical approach for a weighted assessment of the mutagenic potential of nanomaterials. Nanotoxicology 2017; 11:964-977. [DOI: 10.1080/17435390.2017.1382601] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Julia Catalán
- Work Environment, Occupational Safety, Finnish Institute of Occupational Health, Helsinki, Finland
- Department of Anatomy, Embryology and Genetics, University of Zaragoza, Zaragoza, Spain
| | - Helene Stockmann-Juvala
- Work Environment, Occupational Safety, Finnish Institute of Occupational Health, Helsinki, Finland
| | - Hannu Norppa
- Work Environment, Occupational Safety, Finnish Institute of Occupational Health, Helsinki, Finland
| |
Collapse
|
24
|
Advances in Production and Applications of Carbon Nanotubes. Top Curr Chem (Cham) 2017; 375:18. [DOI: 10.1007/s41061-017-0102-2] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Accepted: 01/02/2017] [Indexed: 12/27/2022]
|
25
|
Mihalache R, Verbeek J, Graczyk H, Murashov V, van Broekhuizen P. Occupational exposure limits for manufactured nanomaterials, a systematic review. Nanotoxicology 2017; 11:7-19. [DOI: 10.1080/17435390.2016.1262920] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Raluca Mihalache
- Finnish Institute of Occupational Health, Cochrane Work Group, Kuopio, Finland
| | - Jos Verbeek
- Finnish Institute of Occupational Health, Cochrane Work Group, Kuopio, Finland
| | | | - Vladimir Murashov
- National Institute for Occupational Safety and Health, Washington, DC, USA
| | | |
Collapse
|
26
|
The changing face of nanomaterials: Risk assessment challenges along the value chain. Regul Toxicol Pharmacol 2016; 84:105-115. [PMID: 27998719 DOI: 10.1016/j.yrtph.2016.12.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 11/17/2016] [Accepted: 12/15/2016] [Indexed: 12/25/2022]
Abstract
Risk assessment (RA) of manufactured nanomaterials (MNM) is essential for regulatory purposes and risk management activities. Similar to RA of "classical" chemicals, MNM RA requires knowledge about exposure as well as of hazard potential and dose response relationships. What makes MNM RA especially challenging is the multitude of materials (which is expected to increase substantially in the future), the complexity of MNM value chains and life cycles, the accompanying possible changes in material properties over time and in contact with various environmental and organismal milieus, and the difficulties to obtain proper exposure data and to consider the proper dose metric. This article discusses these challenges and also critically overviews the current state of the art regarding MNM RA approaches.
Collapse
|
27
|
Poulsen SS, Jackson P, Kling K, Knudsen KB, Skaug V, Kyjovska ZO, Thomsen BL, Clausen PA, Atluri R, Berthing T, Bengtson S, Wolff H, Jensen KA, Wallin H, Vogel U. Multi-walled carbon nanotube physicochemical properties predict pulmonary inflammation and genotoxicity. Nanotoxicology 2016; 10:1263-75. [PMID: 27323647 PMCID: PMC5020352 DOI: 10.1080/17435390.2016.1202351] [Citation(s) in RCA: 103] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Lung deposition of multi-walled carbon nanotubes (MWCNT) induces pulmonary toxicity. Commercial MWCNT vary greatly in physicochemical properties and consequently in biological effects. To identify determinants of MWCNT-induced toxicity, we analyzed the effects of pulmonary exposure to 10 commercial MWCNT (supplied in three groups of different dimensions, with one pristine and two/three surface modified in each group). We characterized morphology, chemical composition, surface area and functionalization levels. MWCNT were deposited in lungs of female C57BL/6J mice by intratracheal instillation of 0, 6, 18 or 54 μg/mouse. Pulmonary inflammation (neutrophil influx in bronchoalveolar lavage (BAL)) and genotoxicity were determined on day 1, 28 or 92. Histopathology of the lungs was performed on day 28 and 92. All MWCNT induced similar histological changes. Lymphocytic aggregates were detected for all MWCNT on day 28 and 92. Using adjusted, multiple regression analyses, inflammation and genotoxicity were related to dose, time and physicochemical properties. The specific surface area (BET) was identified as a positive predictor of pulmonary inflammation on all post-exposure days. In addition, length significantly predicted pulmonary inflammation, whereas surface oxidation (–OH and –COOH) was predictor of lowered inflammation on day 28. BET surface area, and therefore diameter, significantly predicted genotoxicity in BAL fluid cells and lung tissue such that lower BET surface area or correspondingly larger diameter was associated with increased genotoxicity. This study provides information on possible toxicity-driving physicochemical properties of MWCNT. The results may contribute to safe-by-design manufacturing of MWCNT, thereby minimizing adverse effects.
Collapse
Affiliation(s)
- Sarah S Poulsen
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Petra Jackson
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Kirsten Kling
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Kristina B Knudsen
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Vidar Skaug
- b National Institute of Occupational Health , Oslo , Norway
| | - Zdenka O Kyjovska
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Birthe L Thomsen
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Per Axel Clausen
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Rambabu Atluri
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Trine Berthing
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Stefan Bengtson
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Henrik Wolff
- c Finnish Institute of Occupational Health , Helsinki , Finland
| | - Keld A Jensen
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark
| | - Håkan Wallin
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark .,d Institute of Public Health, Copenhagen University , Copenhagen K , Denmark , and
| | - Ulla Vogel
- a National Research Centre for the Working Environment , Copenhagen Ø , Denmark .,e Department of Micro-and Nanotechnology , Technical University of Denmark , Kgs. Lyngby , Denmark
| |
Collapse
|
28
|
Schulte PA, Roth G, Hodson LL, Murashov V, Hoover MD, Zumwalde R, Kuempel ED, Geraci CL, Stefaniak AB, Castranova V, Howard J. Taking stock of the occupational safety and health challenges of nanotechnology: 2000-2015. JOURNAL OF NANOPARTICLE RESEARCH : AN INTERDISCIPLINARY FORUM FOR NANOSCALE SCIENCE AND TECHNOLOGY 2016; 18:159. [PMID: 27594804 PMCID: PMC5007006 DOI: 10.1007/s11051-016-3459-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Engineered nanomaterials significantly entered commerce at the beginning of the 21st century. Concerns about serious potential health effects of nanomaterials were widespread. Now, approximately 15 years later, it is worthwhile to take stock of research and efforts to protect nanomaterial workers from potential risks of adverse health effects. This article provides and examines timelines for major functional areas (toxicology, metrology, exposure assessment, engineering controls and personal protective equipment, risk assessment, risk management, medical surveillance, and epidemiology) to identify significant contributions to worker safety and health. The occupational safety and health field has responded effectively to identify gaps in knowledge and practice, but further research is warranted and is described. There is now a greater, if imperfect, understanding of the mechanisms underlying nanoparticle toxicology, hazards to workers, and appropriate controls for nanomaterials, but unified analytical standards and exposure characterization methods are still lacking. The development of control-banding and similar strategies has compensated for incomplete data on exposure and risk, but it is unknown how widely such approaches are being adopted. Although the importance of epidemiologic studies and medical surveillance is recognized, implementation has been slowed by logistical issues. Responsible development of nanotechnology requires protection of workers at all stages of the technological life cycle. In each of the functional areas assessed, progress has been made, but more is required.
Collapse
Affiliation(s)
- P. A. Schulte
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - G. Roth
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - L. L. Hodson
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - V. Murashov
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - M. D. Hoover
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - R. Zumwalde
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - E. D. Kuempel
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - C. L. Geraci
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - A. B. Stefaniak
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| | - V. Castranova
- School of Pharmacy, West Virginia University, Morgantown, WV, USA
| | - J. Howard
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
| |
Collapse
|
29
|
Luanpitpong S, Wang L, Davidson DC, Riedel H, Rojanasakul Y. Carcinogenic Potential of High Aspect Ratio Carbon Nanomaterials. ENVIRONMENTAL SCIENCE. NANO 2016; 3:483-493. [PMID: 27570625 PMCID: PMC4996468 DOI: 10.1039/c5en00238a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Engineered nanomaterials, including high aspect ratio carbon nanomaterials, are often commercialized without a complete human risk assessment and safety evaluation. A health concern has been raised that high aspect ratio nanomaterials such as carbon nanotubes may cause unintended health consequences, such as asbestos-like lung cancer and mesothelioma, when chronically inhaled. Considering the widespread industrial and clinical applications and the increasing incidence of human exposure to nanomaterials, it is important to address the issue of nanomaterial carcinogenicity in a timely manner. This review summarizes recent advances in nanomaterial genotoxicity and carcinogenicity with a focus on high aspect ratio carbon nanotubes, and discusses current knowledge gaps and future research directions.
Collapse
Affiliation(s)
- Sudjit Luanpitpong
- Siriraj Center of Excellence for Stem Cell Research, Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV 26506, USA
| | - Liying Wang
- Allergy and Clinical Immunology Branch, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
| | - Donna C. Davidson
- Allergy and Clinical Immunology Branch, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
| | - Heimo Riedel
- Department of Biochemistry, West Virginia University, Morgantown, WV 26506, USA
- Mary Babb Randolph Cancer Center, West Virginia University, Morgantown, WV 26506, USA
| | - Yon Rojanasakul
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV 26506, USA
- Mary Babb Randolph Cancer Center, West Virginia University, Morgantown, WV 26506, USA
| |
Collapse
|
30
|
Sajid MI, Jamshaid U, Jamshaid T, Zafar N, Fessi H, Elaissari A. Carbon nanotubes from synthesis to in vivo biomedical applications. Int J Pharm 2016; 501:278-99. [DOI: 10.1016/j.ijpharm.2016.01.064] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 01/11/2016] [Accepted: 01/25/2016] [Indexed: 10/22/2022]
|