1
|
Sayin O, Altinkaynak H. Macular Pigment Optical Density in First Degree Relatives of Age-Related Macular Degeneration Patients. Curr Eye Res 2023; 48:1057-1062. [PMID: 37494149 DOI: 10.1080/02713683.2023.2242012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Revised: 07/05/2023] [Accepted: 07/24/2023] [Indexed: 07/28/2023]
Abstract
PURPOSE To measure the macular pigment optical density in first-degree relatives of patients with age-related macular degeneration and compare it with a healthy control group. METHODS One hundred and twenty-eight healthy subjects who were first-degree relatives of age-related macular degeneration patients were included in the study (Group 1). As the control group, 74 healthy subjects were included in the study (Group 2). The right eyes of all cases were included in the study. Macular pigment optical density was measured with a commercially available device (MPSII®, Elektron Technology, Switzerland) using technology based on heterochromatic flicker photometry. Central foveal thickness and subfoveal choroidal thickness were measured with spectral-domain optical coherence tomography. Values were compared between the two groups. RESULTS There were 54 males and 74 females in Group 1 and 32 males and 42 females in Group 2. The mean ± SD ages of Group 1 and Group 2 were 49.0 ± 7.6 and 41.8 ± 8.6, respectively. Mean ± SD macular pigment optical density values of Group 1 and Group 2 were 0.43 ± 0.09 and 0.47 ± 0.12 (p = 0.048), mean ± SD central foveal thickness were 208 ± 19 and 216 ± 8 µm (p = 0.014), and mean ± SD subfoveal choroidal thickness were 232 ± 29 and 250 ± 21 µm (p = 0.002), respectively. CONCLUSION The macular pigment optical density values were significantly lower in the first-degree relatives of patients with age-related macular degeneration than in the control group. Macular pigment optical density may be a marker for the development of age-related macular degeneration in the future in the first-degree relatives of age-related macular degeneration patients. Further prospective studies with a larger number of participants will be needed to confirm our results moreover, to clarify its benefit as an early diagnostic biomarker.
Collapse
Affiliation(s)
- Osman Sayin
- Department of Ophthalmology, Konya City Hospital, Konya, Turkey
| | | |
Collapse
|
2
|
Sae-Lao W, Wunjuntuk K, Techakriengkrai T, Sirichakwal PP, Yaisawang S, Kom-on S. Macular pigment optical density in a Thai sample. EXPERT REVIEW OF OPHTHALMOLOGY 2022. [DOI: 10.1080/17469899.2022.2085558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Wipada Sae-Lao
- Faculty of Agriculture, Kasetsart University, Bangkok, Thailand
| | | | | | | | | | | |
Collapse
|
3
|
Macular Pigment Reflectometry: Developing Clinical Protocols, Comparison with Heterochromatic Flicker Photometry and Individual Carotenoid Levels. Nutrients 2021; 13:nu13082553. [PMID: 34444721 PMCID: PMC8399813 DOI: 10.3390/nu13082553] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 07/21/2021] [Accepted: 07/23/2021] [Indexed: 12/26/2022] Open
Abstract
The study was designed to: (1) Analyze and create protocols of obtaining measurements using the Macular Pigment Reflectometry (MPR). (2) To assess the agreement of MPOD measurements obtained using the heterochromatic flicker photometry (MPS II) and MPR. (3) To obtain the lutein and zeaxanthin optical density obtained using the MPR in the central one-degree of the macula. The measurements were performed using the MPR and heterochromatic flicker photometry. The MPR measurements were performed twice without pupillary dilation and twice following pupillary dilation. The MPR measurements were performed for a 40-s period and the spectrometer signal was parsed at different time points: 10–20, 10–30, 10–40, 20–30, 20–40, and 30–40 s. The MPR analyzes the high-resolution spectrometer signal and calculates MPOD, lutein optical density and zeaxanthin optical density automatically. The MPR-MPOD data was compared with MPPS II-MPOD results. The MPR-MPOD values are highly correlated and in good agreement with the MPS II-MPOD. Of the various parsing of the data, the data 10–30 interval was the best at obtaining the MPOD, lutein, and zeaxanthin values (8–12% coefficient of repeatability). The lutein to zeaxanthin ratio in the central one-degree of the macula was 1:2.40. Dilation was not needed to obtain the MPOD values but provided better repeatability of lutein and zeaxanthin optical density. MPR generates MPOD measurements that is in good agreement with MPS II. The device can produce lutein and zeaxanthin optical density which is not available from other clinical devices.
Collapse
|
4
|
Hayashi R, Hayashi S, Machida S. Changes in macular pigment optical density among pseudophakic patients following intake of a lutein-containing supplement. Ophthalmic Res 2021; 64:828-836. [PMID: 34148037 DOI: 10.1159/000517573] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Accepted: 05/29/2021] [Indexed: 11/19/2022]
Affiliation(s)
- Rijo Hayashi
- Department of Ophthalmology, Saitama Medical Center, Dokkyo Medical University, Koshigaya, Japan
| | - Shimmin Hayashi
- Department of Ophthalmology, Saitama Medical Center, Dokkyo Medical University, Koshigaya, Japan
- Lively Eye Clinic, Soka, Japan
| | - Shigeki Machida
- Department of Ophthalmology, Saitama Medical Center, Dokkyo Medical University, Koshigaya, Japan
| |
Collapse
|
5
|
Bartlett H, Howells O, Eperjesi F. The role of macular pigment assessment in clinical practice: a review. Clin Exp Optom 2021; 93:300-8. [DOI: 10.1111/j.1444-0938.2010.00499.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Affiliation(s)
- Hannah Bartlett
- Ophthalmic Research Group, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom
E‐mail:
| | - Olivia Howells
- Ophthalmic Research Group, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom
E‐mail:
| | - Frank Eperjesi
- Ophthalmic Research Group, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom
E‐mail:
| |
Collapse
|
6
|
Polat Gultekin B, Sahli E. Macular pigment optical density in central serous chorioretinopathy. Ther Adv Ophthalmol 2021; 13:2515841421997195. [PMID: 33738428 PMCID: PMC7934065 DOI: 10.1177/2515841421997195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 01/27/2021] [Indexed: 11/16/2022] Open
Abstract
Purpose The aim of our study was to evaluate the macular pigment optical density in patients with acute and chronic central serous chorioretinopathy and to describe the association between central retinal thickness and choroidal thickness with the macular pigment optical density. Materials and Methods Eyes with acute central serous chorioretinopathy and chronic central serous chorioretinopathy (patients, who were diagnosed as having disease activity for 6 months) were included in this study. Macular pigment was measured using the heterochromatic flicker technique of the MPS II device for both eyes in patients with acute and chronic central serous chorioretinopathy and in control subjects. Results Twenty-seven eyes with acute central serous chorioretinopathy, 23 eyes with chronic central serous chorioretinopathy, and 25 control eyes were enrolled. The mean macular pigment optical density in chronic central serous chorioretinopathy (0.480 ± 0.16 density unit (95% confidence interval: 0.390-0.570) was found to be significantly lower than in the control eyes (0.571 ± 0.128 density unit) (95% confidence interval: 0.480-0.670) (p = 0.007). In correlation analysis, no significant association was detected between the central retinal thickness, choroidal thickness, and macular pigment optical density values in central serous chorioretinopathy group (p = 0.31, p = 0.71). Conclusion Macular pigment optical density levels were significantly lower in chronic central serous chorioretinopathy patients than in controls, possibly due to degeneration of the neurosensorial retina, as a result of the long-term persistence of subretinal fluid. There was not a significant correlation between choroidal thickness and macular pigment optical density levels in central serous chorioretinopathy group.
Collapse
Affiliation(s)
- Burcu Polat Gultekin
- Department of Ophthalmology, Ministry of Health Ankara City Hospital, Ankara 06800, Turkey
| | - Esra Sahli
- Department of Ophthalmology, Ankara University Medical Faculty, Ankara, Turkey
| |
Collapse
|
7
|
Rutledge GA, Pratt SG, Richer SP, Huntjens B, Perry CB, Pratt G, Podella C. Foveal macular pigment dip in offspring of age-related macular degeneration patients is inversely associated with omega-3 index. BMC Ophthalmol 2020; 20:473. [PMID: 33267825 PMCID: PMC7709463 DOI: 10.1186/s12886-020-01742-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 11/23/2020] [Indexed: 12/23/2022] Open
Abstract
Background Offspring of parent(s) with age-related macular degeneration (AMD) have a 45% lifetime risk of developing the disease. High foveal macular pigment optical density (MPOD) is protective, whereas individuals with a “foveal macular pigment dip” (FMPD) are at increased risk. Shortage of the dietary carotenoids lutein, zeaxanthin as well as fish consumption are reported AMD risk factors. This Early Biomarkers of AMD (EBAMD) study evaluates serum factors that protect foveal MPOD architecture in Caucasian offspring of parent(s) with AMD. Methods N = 130 subjects [mean (SD) age 62.8 (8.6) years; 36/94 male/female] were recruited from Scripps Health/ Scripps Memorial Hospital/ Scripps Mericos Eye Institute between 2012 and 2017. Macula pigment 3D topography was evaluated using specular reflectance. Buccal genetic cheek swab, circulating serum dietary carotenoids and long-term RBC omega-3 fatty acid status, as well as common secondary clinical structural and vision function parameters were obtained. Results 41 % of offspring of AMD parent(s) presented with FMPD. These offspring were about 4 years younger than those without FMPD (controls; P = 0.012) and had thinner foveas (P = 0.010). There were no differences in gender, BMI, % body fat, visual acuity or contrast sensitivity between those with and without FMPD. % RBC membrane docosahexaenoic acid (DHA) was reduced in FMPD offspring vs. control offspring (P = 0.04). The Omega-3 Index was significantly decreased in the FMPD group (P = 0.03). Conclusions The percentage of FMPD in AMD offspring is nearly twice that reported for the general population in the scientific literature. Offspring presenting FMPD had similar AMD genetic risk, but significantly reduced % RBC membrane omega-3 fatty acids and thinner foveas compared with those without FMPD. Our data supports the importance of ‘essential fatty’ acids as an independent AMD risk factor.
Collapse
Affiliation(s)
- Grant A Rutledge
- Scripps Health/Scripps Memorial Hospital/Scripps Mericos Eye Institute - Scripps Clinical Research Service, La Jolla, CA, USA. .,Department of Ecology and Evolutionary Biology, University of California, Irvine, CA, USA. .,USDA Human Nutrition Research Center on Aging, Boston, MA, USA.
| | - Steven G Pratt
- Scripps Health/Scripps Memorial Hospital/Scripps Mericos Eye Institute - Scripps Clinical Research Service, La Jolla, CA, USA
| | - Stuart P Richer
- Eye Clinics, Captain James A. Lovell Federal Health Care Center, North Chicago, IL, USA
| | - Byki Huntjens
- Centre for Applied Vision Research, Division of Optometry and Vision Sciences, City, University of London, London, UK
| | - C Blake Perry
- Scripps Health/Scripps Memorial Hospital/Scripps Mericos Eye Institute - Scripps Clinical Research Service, La Jolla, CA, USA
| | - Gunilla Pratt
- Scripps Health/Scripps Memorial Hospital/Scripps Mericos Eye Institute - Scripps Clinical Research Service, La Jolla, CA, USA
| | - Carla Podella
- Eye Clinics, Captain James A. Lovell Federal Health Care Center, North Chicago, IL, USA
| |
Collapse
|
8
|
Huchzermeyer C, Fars J, Kremers J. Photoreceptor-Specific Loss of Perifoveal Temporal Contrast Sensitivity in Retinitis Pigmentosa. Transl Vis Sci Technol 2020; 9:27. [PMID: 32821524 PMCID: PMC7409023 DOI: 10.1167/tvst.9.6.27] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 04/01/2020] [Indexed: 02/07/2023] Open
Abstract
Purpose Inherited retinal diseases affect the L-, M-, S-cones and rods in distinct ways, which calls for new methods that enable quantification of photoreceptor-specific functions. We tested the feasibility of using the silent substitution paradigm to estimate photoreceptor-driven temporal contrast sensitivity (tCS) functions in patients with retinitis pigmentosa. Methods The silent substitution paradigm is based on substitution of lights of different spectral composition; this offers considerable advantage over other stimulation techniques. We used a four-primary LED stimulator to create perifoveal annular stimuli (2° inner, 12° outer diameters) and used a triple silent substitution to probe photoreceptor-selective tCS. Measurements were performed in a heterogeneous cohort of 15 patients with retinitis pigmentosa and related to those in a control group of nine color-normal healthy observers. Age differences between groups were addressed with a model of age-related normal contrast sensitivity derived from measurements in 20 healthy observers aged between 23 and 83 years. Results The age-related loss of tCS amounted to 0.1 dB/year in healthy subjects across all photoreceptor subtypes. In patients, tCS was decreased for every photoreceptor subtype; however, S-cone- and rod-driven sensitivities were most strongly affected. Postreceptoral mechanisms were not affected. Conclusions This feasibility study provides evidence that the silent substitution technique enables the estimation of photoreceptor-selective tCS functions and can serve as an accurate biomarker of photoreceptor-specific contrast sensitivity loss in patients with retinitis pigmentosa. Translational Relevance We aim to develop tests of visual function for clinical trials of novel therapies for inherited retinal diseases from methods that can currently be used only in vision research labs.
Collapse
Affiliation(s)
- Cord Huchzermeyer
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| | - Julien Fars
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| | - Jan Kremers
- Department of Ophthalmology, University Hospital Erlangen, Erlangen, Germany
| |
Collapse
|
9
|
Romano MR, Cennamo G, Grassi P, Sparnelli F, Allegrini D, Cennamo G. Changes in macular pigment optical density after membrane peeling. PLoS One 2018; 13:e0197034. [PMID: 29758035 PMCID: PMC5951543 DOI: 10.1371/journal.pone.0197034] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2017] [Accepted: 04/25/2018] [Indexed: 12/03/2022] Open
Abstract
Introduction To highlight the differences in macular pigment optical density (MPOD) between eyes with vitreoretinal interface syndrome and healthy control eyes, to assess the changes in MPOD in eyes treated with macular peeling, to investigate the relationships between MPOD changes and measures of retinal sensitivity such as best corrected visual acuity (BCVA) and microperimetry. Methods In this cross-sectional comparative study, 30 eyes affected by idiopathic epiretinal membrane (iERM, 15eyes) or full-thickness macular hole (FTMH, 15eyes) were compared with 60 eyes from 30 healthy age-matched patients. MPOD values (mean MPOD, maximum MPOD, MPOD area, and MPOD volume) were measured in a range of 4°–7° of eccentricity around the fovea, using the one-wavelength reflectometry method (Visucam 200, Carl-Zeiss Meditec). Patients affected by iERM and FTMH were treated with vitrectomy and epiretinal membrane-inner limiting membrane (ERM-ILM) peeling, with follow-up examinations performed preoperatively and 6 months postoperatively. The main outcome measures were the differences in MPOD between eyes with vitreoretinal interface syndrome and healthy eyes, changes in MPOD after ERM-ILM peeling, and relationships between MPOD and functional changes. Results Mean MPOD differed significantly between control eyes and those with iERM (P = .0001) or FTMH (P = .0006). The max MPOD and MPOD area increased, but not significantly. After peeling, the only significant change in MPOD was in MPOD volume (P = .01). In the ERM group, postoperative mean MPOD correlated significantly with best-corrected visual acuity (r = .739, P = .002). Conclusions MPOD was reduced in patients with iERM or FTMH compared with healthy eyes. We found a significant correlation between the mean postoperative MPOD and postoperative BCVA, hypothesizing that the postoperative increase in mean MPOD could be due to a change in distribution for unfolding and expansion of the fovea after the peeling. MOPD may be considered as a prognostic factor associated with a good visual prognosis in patients with iERM.
Collapse
Affiliation(s)
- Mario R. Romano
- Eye Clinic, Department of Bioscience, Humanitas University, Rozzano, Milan, Italy
- Eye Clinic, Department of Neuroscience, University Federico II, Naples, Italy
| | - Gilda Cennamo
- Eye Clinic, Department of Neuroscience, University Federico II, Naples, Italy
| | - Piergiacomo Grassi
- Eye Clinic, Department of Neuroscience, University Federico II, Naples, Italy
| | - Federica Sparnelli
- Eye Clinic, Department of Neuroscience, University Federico II, Naples, Italy
| | - Davide Allegrini
- Eye Clinic, Department of Bioscience, Humanitas University, Rozzano, Milan, Italy
- * E-mail:
| | - Giovanni Cennamo
- Eye Clinic, Department of Neuroscience, University Federico II, Naples, Italy
| |
Collapse
|
10
|
Jorge LPC, Pereira CEG, Jorge E, de Ávila MP. Macular pigment optical density in a Brazilian sample. Int J Retina Vitreous 2018; 4:4. [PMID: 29387455 PMCID: PMC5776767 DOI: 10.1186/s40942-018-0107-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Accepted: 01/06/2018] [Indexed: 01/21/2023] Open
Abstract
Background To evaluate macular pigment optical density (MPOD) and to identify its determinants in a sample of Brazilian individuals. Methods This was a cross-sectional study. One hundred three healthy individuals had both eyes photographed using a Visucam 500 digital fundus camera (Carl Zeiss Meditec, Jena, Germany) in combination with the MPOD module. Four variables were obtained: maximum MPOD, mean MPOD, MPOD volume, and MPOD area. Demographic data and information on lifestyle habits were also collected.
Results Mean MPOD was 0.14 density unit ± 0.05. MPOD was not influenced by gender, smoking history, or refractive error. MPOD was significantly higher among black individuals than among white and biracial individuals. There was a positive but low correlation between MPOD and age. Conclusion This study found MPOD values to be similar to those found in European samples but lower than other studies performed on Asian and Australian samples. This is the first data regarding MPOD in a South American Population.
Collapse
Affiliation(s)
| | | | - Eduardo Jorge
- Instituto Panamericano da Visão, Street T 8 No. 171 Setor Marista, 74150-060 Goiânia, GO Brazil
| | - Marcos Pereira de Ávila
- 2Universidade Federal de Goiás, Av 1 No. 355 Setor Universitário, 74605-020 Goiânia, GO Brazil
| |
Collapse
|
11
|
Putnam CM. Clinical imaging of macular pigment optical density and spatial distribution. Clin Exp Optom 2016; 100:333-340. [PMID: 27885710 DOI: 10.1111/cxo.12500] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 09/14/2016] [Accepted: 09/20/2016] [Indexed: 11/29/2022] Open
Abstract
Clinical research continues to provide an increasing number of studies that reveal an association between macular pigment optical density (MPOD) and both visual function and ocular health. As a result, there is a growing need for repeatable, accurate measures of MPOD that can describe peak optical density as well as spatial distribution. Measurement of MPOD in a research setting has an established history encompassing a number of both objective and subjective techniques. Transition of these techniques to a clinical setting has produced an array of commercial devices using three primary methods: heterochromatic flicker photometry, fundus autofluorescence and fundus reflectometry. The inherent differences among the techniques create difficulty in making direct comparisons between MPOD measurement devices. Understanding the limitations of each technique is critical in the clinical interpretation of MPOD results. Here, both the objective and subjective methods of MPOD measurement are reviewed with emphasis on the commercially available devices used in clinical settings.
Collapse
|
12
|
Kaluzny J, Li H, Liu W, Nesper P, Park J, Zhang HF, Fawzi AA. Bayer Filter Snapshot Hyperspectral Fundus Camera for Human Retinal Imaging. Curr Eye Res 2016; 42:629-635. [PMID: 27767345 DOI: 10.1080/02713683.2016.1221976] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE To demonstrate the versatility and performance of a compact Bayer filter snapshot hyperspectral fundus camera for in-vivo clinical applications including retinal oximetry and macular pigment optical density measurements. METHODS 12 healthy volunteers were recruited under an Institutional Review Board (IRB) approved protocol. Fundus images were taken with a custom hyperspectral camera with a spectral range of 460-630 nm. We determined retinal vascular oxygen saturation (sO2) for the healthy population using the captured spectra by least squares curve fitting. Additionally, macular pigment optical density was localized and visualized using multispectral reflectometry from selected wavelengths. RESULTS We successfully determined the mean sO2 of arteries and veins of each subject (ages 21-80) with excellent intrasubject repeatability (1.4% standard deviation). The mean arterial sO2 for all subjects was 90.9% ± 2.5%, whereas the mean venous sO2 for all subjects was 64.5% ± 3.5%. The mean artery-vein (A-V) difference in sO2 varied between 20.5% and 31.9%. In addition, we were able to reveal and quantify macular pigment optical density. CONCLUSIONS We demonstrated a single imaging tool capable of oxygen saturation and macular pigment density measurements in vivo. The unique combination of broad spectral range, high spectral-spatial resolution, rapid and robust imaging capability, and compact design make this system a valuable tool for multifunction spectral imaging that can be easily performed in a clinic setting.
Collapse
Affiliation(s)
- Joel Kaluzny
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Hao Li
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| | - Wenzhong Liu
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| | - Peter Nesper
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Justin Park
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Hao F Zhang
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| | - Amani A Fawzi
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
| |
Collapse
|
13
|
Evidence of macular pigment in the central macula in albinism. Exp Eye Res 2016; 145:468-471. [DOI: 10.1016/j.exer.2015.10.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2015] [Revised: 08/30/2015] [Accepted: 10/05/2015] [Indexed: 11/21/2022]
|
14
|
Increased Macular Pigment Optical Density and Visual Acuity following Consumption of a Buttermilk Drink Containing Lutein-Enriched Egg Yolks: A Randomized, Double-Blind, Placebo-Controlled Trial. J Ophthalmol 2016; 2016:9035745. [PMID: 27064326 PMCID: PMC4808677 DOI: 10.1155/2016/9035745] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Accepted: 02/25/2016] [Indexed: 11/24/2022] Open
Abstract
Purpose. To study the effect of 1-year daily consumption of a dairy drink containing lutein-enriched egg yolks on macular pigment optical density (MPOD) and visual function parameters in elderly subjects with ocular drusen and/or retinal pigment abnormalities. Methods. One hundred and one subjects were recruited to participate in this randomized, double-blind, placebo-controlled parallel intervention trial. Statistical analyses were performed with 46 subjects in the lutein group and 43 in the control group. MPOD, best corrected visual acuity (BCVA, logMAR), and dark adaptation were measured at the start of the study, after 6 months and after 12 months. Plasma lutein and zeaxanthin concentrations were assessed at baseline and at the end of the study. Results. In the lutein group, plasma lutein concentrations increased significantly from 205 ng/mL at baseline to 399 ng/mL after twelve months of intervention. MPOD increased significantly from 0.45 to 0.52 and BCVA improved significantly from −0.04 to −0.09 LogMar. Differences in rod dark adaptation rate between both groups were not significant. Conclusion. Daily consumption of a dairy drink containing lutein-enriched egg yolks for one year improves visual acuity, MPOD, and plasma lutein concentration in elderly subjects with drusen and/or retinal pigment epithelial abnormalities.
Collapse
|
15
|
Lutein, Zeaxanthin, and meso-Zeaxanthin in the Clinical Management of Eye Disease. J Ophthalmol 2015; 2015:865179. [PMID: 26819755 PMCID: PMC4706936 DOI: 10.1155/2015/865179] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 11/29/2015] [Indexed: 11/18/2022] Open
Abstract
Lutein, zeaxanthin, and meso-zeaxanthin are xanthophyll carotenoids found within the retina and throughout the visual system. The retina is one of the most metabolically active tissues in the body. The highest concentration of xanthophylls is found within the retina, and this selective presence has generated many theories regarding their role in supporting retinal function. Subsequently, the effect of xanthophylls in the prevention and treatment of various eye diseases has been examined through epidemiological studies, animal studies, and clinical trials. This paper attempts to review the epidemiological studies and clinical trials investigating the effects of xanthophylls on the incidence and progression of various eye diseases. Observational studies have reported that increased dietary intake and higher serum levels of lutein and zeaxanthin are associated with lower risk of age-related macular degeneration (AMD), especially late AMD. Randomized, placebo-controlled clinical trials have demonstrated that xanthophyll supplementation increases macular pigment levels, improves visual function, and decreases the risk of progression to late AMD, especially neovascular AMD. Current publications on the preventive and therapeutic effects of lutein and zeaxanthin on cataracts, diabetic retinopathy, and retinopathy of prematurity have reported encouraging results.
Collapse
|
16
|
Smollon WE, Wooten BR, Hammond BR. Stimulus edge effects in the measurement of macular pigment using heterochromatic flicker photometry. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:115004. [PMID: 26562031 DOI: 10.1117/1.jbo.20.11.115004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2015] [Accepted: 10/13/2015] [Indexed: 06/05/2023]
Abstract
Heterochromatic flicker photometry (HFP) is the most common technique of measuring macular pigment optical density (MPOD). Some data strongly suggest that HFP samples MPOD specifically at the edge of center-fixated circular stimuli. Other data have led to the conclusion that HFP samples over the entire area of the stimulus. To resolve this disparity, MPOD was measured using HFP and a series of solid discs of varying radii (0.25 to 2.0 deg) and with thin annuli corresponding to the edge of those discs. MPOD assessed with the two methods yielded excellent correspondence and linearity: Y=0.01+0.98X , r=0.96. A second set of experiments showed that if a disc stimulus is adjusted for no-flicker (the standard procedure) and simply reduced in size, no flicker is observed despite the higher level of MPOD in the smaller area. Taken together, these results confirm that MPOD is determined at the edge of the measuring stimulus when using stimulus sizes in the range that is in dispute (up to a radius of 0.75 deg). The basis for this edge effect can be explained by quantitative differences in the spatial-temporal properties of the visual field as a function of angular distance from the fixation point.
Collapse
Affiliation(s)
- William E Smollon
- Brown University, Department of Psychology, 190 Thayer Street, Providence, Rhode Island 02912, United States
| | - Billy R Wooten
- Brown University, Department of Psychology, 190 Thayer Street, Providence, Rhode Island 02912, United States
| | - Billy R Hammond
- University of Georgia, Brain and Behavioral Sciences, 125 Baldwin Street, Athens, Georgia 30602, United States
| |
Collapse
|
17
|
Chen Y, Lan W, Schaeffel F. Size of the foveal blue scotoma related to the shape of the foveal pit but not to macular pigment. Vision Res 2015; 106:81-9. [DOI: 10.1016/j.visres.2014.10.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 09/15/2014] [Accepted: 10/01/2014] [Indexed: 10/24/2022]
|
18
|
Huchzermeyer C, Schlomberg J, Welge-Lüssen U, Berendschot TTJM, Pokorny J, Kremers J. Macular pigment optical density measured by heterochromatic modulation photometry. PLoS One 2014; 9:e110521. [PMID: 25354049 PMCID: PMC4212909 DOI: 10.1371/journal.pone.0110521] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Accepted: 09/15/2014] [Indexed: 01/05/2023] Open
Abstract
Purpose To psychophysically determine macular pigment optical density (MPOD) employing the heterochromatic modulation photometry (HMP) paradigm by estimating 460 nm absorption at central and peripheral retinal locations. Methods For the HMP measurements, two lights (B: 460 nm and R: 660 nm) were presented in a test field and were modulated in counterphase at medium or high frequencies. The contrasts of the two lights were varied in tandem to determine flicker detection thresholds. Detection thresholds were measured for different R:B modulation ratios. The modulation ratio with minimal sensitivity (maximal threshold) is the point of equiluminance. Measurements were performed in 25 normal subjects (11 male, 14 female; age: 30±11 years, mean ± sd) using an eight channel LED stimulator with Maxwellian view optics. The results were compared with those from two published techniques – one based on heterochromatic flicker photometry (Macular Densitometer) and the other on fundus reflectometry (MPR). Results We were able to estimate MPOD with HMP using a modified theoretical model that was fitted to the HMP data. The resultant MPODHMP values correlated significantly with the MPODMPR values and with the MPODHFP values obtained at 0.25° and 0.5° retinal eccentricity. Conclusions HMP is a flicker-based method with measurements taken at a constant mean chromaticity and luminance. The data can be well fit by a model that allows all data points to contribute to the photometric equality estimate. Therefore, we think that HMP may be a useful method for MPOD measurements, in basic and clinical vision experiments.
Collapse
Affiliation(s)
- Cord Huchzermeyer
- University Eye Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
- * E-mail: (CH); (JK)
| | - Juliane Schlomberg
- University Eye Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
- Department of Ophthalmology, Charité, University Medicine Berlin, Berlin, Germany
| | - Ulrich Welge-Lüssen
- University Eye Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
| | | | - Joel Pokorny
- Department of Ophthalmology and Visual Sciences, University of Chicago, Chicago, Illinois, United States of America
| | - Jan Kremers
- University Eye Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Erlangen, Germany
- * E-mail: (CH); (JK)
| |
Collapse
|
19
|
|
20
|
Baptista AMG, Nascimento SMC. Changes in spatial extent and peak double optical density of human macular pigment with age. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2014; 31:A87-A92. [PMID: 24695208 DOI: 10.1364/josaa.31.000a87] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The purpose of the present work was to estimate the changes in spatial distribution and optical density of macular pigment (MP) with age. A fundus imaging system with high spatial and spectral resolution was adapted to form an indirect ophthalmoscope. The double optical density at 490 nm of the MP as a function of the location in the retina was obtained for 33 healthy subjects (ages: 21-60 years). There was an increase in spatial extent and decrease in double optical density with age. Furthermore, the spatial distribution of MP showed central areas with irregular shapes and a tendency toward asymmetry.
Collapse
|
21
|
O'Brien A, Leahy C, Dainty C. Imaging system to assess objectively the optical density of the macular pigment in vivo. APPLIED OPTICS 2013; 52:6201-6212. [PMID: 24085078 DOI: 10.1364/ao.52.006201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Accepted: 06/27/2013] [Indexed: 06/02/2023]
Abstract
This paper presents an optical system called MacPI, which implements a two-color reflectance technique in combination with various hardware and software tools to assess objectively the macular pigment (MP) optical density in vivo. The system consists of a bespoke optical design, a control architecture, driver electronics, a collection of image-processing techniques, and a graphical user interface. The deficiencies of the technique employed and the solutions implemented in the MacPI system to confront those inherent frailties are presented. An overview of the effective interpretation of the acquired data and the techniques employed by MacPI in the acquisition of that data is discussed. The result of a comparison trial with an alternative device is also presented. We suggest that appropriate design of the hardware and an efficient interpretation of the acquired data should produce a system capable of consistent, accurate, and rapid measurements, while retaining the distinction of ease of use, portability, comfort for the subject, and a design that is economic to produce. Its versatility should allow both for a clinical screening application and for further investigation and establishment of the physiological role of the MP in a laboratory-based environment.
Collapse
|
22
|
Murray IJ, Hassanali B, Carden D. Macular pigment in ophthalmic practice; a survey. Graefes Arch Clin Exp Ophthalmol 2013; 251:2355-62. [PMID: 23912797 DOI: 10.1007/s00417-013-2430-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2013] [Revised: 06/25/2013] [Accepted: 07/11/2013] [Indexed: 10/26/2022] Open
Abstract
BACKGROUND Macular pigment (MP) might provide some protection against age-related eye disease, and it is now being measured in ophthalmic practice. The purpose of the survey described here was to determine the distribution of MP in a random population of patients in a typical UK ophthalmic practice. METHODS Macular pigment optical density (MPOD) was measured in 56 patients aged 11 to 87 years, mean 52 ± 19, over a 3-month period. Typically, the test requires setting flicker thresholds for a centrally and peripherally viewed blue/green alternating target. Here we describe the results when an age-based estimate of the peripheral value is used, thus avoiding the peripheral setting. In 32 observers, a comparison was made between this and values obtained with the centre and periphery method. Information on smoking habits, iris colour, diabetic status, and ethnicity were recorded. RESULTS The overall average MPOD for the population obtained with the centre-only approach for 56 individuals was 0.400 ± 0.165. The centre-only technique was an accurate predictor of values based on centre and peripheral measures, with 95% limits of agreement of 0.137 OD units. Pearson's correlation coefficient showed a high correlation between right and left eyes (r = 0.7 (p < 0.001)). There was a small difference between males and females that did not reach statistical significance (r = -0.22). There was a non-statistically significant age-related decline in MPOD in this particular population (r = -0.17). Dark irides were significantly associated with high MPOD (r = 0.28, p < 0.05). MPOD in Type II diabetic patients was 27% lower than that in non-diabetics (r = 0.29, p < 0.05). CONCLUSION The technique provides similar values of MP optical density to previous reports. As with other HFP-based methods, in a small percentage of older patients, more than one measurement is required before satisfactory results are obtained.
Collapse
Affiliation(s)
- Ian J Murray
- Faculty of Life Sciences, University of Manchester, Carys Bannister Building, Dover St, Manchester, M13 9PL, UK,
| | | | | |
Collapse
|
23
|
The relationship between foveal short-wavelength-sensitive visual function and macular pigment optical density in the ageing age. Vision Res 2013; 86:81-6. [DOI: 10.1016/j.visres.2013.04.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2012] [Revised: 12/20/2012] [Accepted: 04/02/2013] [Indexed: 11/21/2022]
|
24
|
Kaya S, Weigert G, Pemp B, Sacu S, Werkmeister RM, Dragostinoff N, Garhöfer G, Schmidt-Erfurth U, Schmetterer L. Comparison of macular pigment in patients with age-related macular degeneration and healthy control subjects - a study using spectral fundus reflectance. Acta Ophthalmol 2012; 90:e399-403. [PMID: 23035764 DOI: 10.1111/j.1755-3768.2012.02423.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE Previous studies have reported an age-dependent decline of macular pigment optical density (MPOD) as well as a relative lack of MPOD in age-related macular degeneration (AMD). Results are, however, strongly dependent on the technique used. In this study, we investigated the age dependence of MPOD using spectral fundus reflectance. In addition, we hypothesized that patients with AMD have a reduced MPOD as compared to healthy controls. METHODS A total of 85 healthy subjects and 96 patients with AMD were included in this study. The healthy control subjects showed a wide range of ages (mean, 51.6 years; range, 21-79years). Patients with AMD were significantly older (mean, 71.2 years; range, 50-89 years). Spectral fundus reflectance of the fovea was measured in a 2.3° detection field with a custom built fundus reflectometer. Calculation of MPOD was based on a previously published fundus reflectance model. RESULTS Patients with AMD showed a reduced MPOD (0.35 ± 0.12) as compared to the healthy control group (0.39 ± 0.12, p = 0.013 between groups). No age dependence of MPOD (r = -0.14, p = 0.19) was found in the healthy control group. In the AMD group, however, MPOD declined with age (r = -0.24, p = 0.019). CONCLUSIONS This study indicates that MPOD is reduced in patients with AMD. In addition, the data of this study indicate that MPOD is age dependent in AMD patients, but not in healthy controls. Taken together with data indicating that lutein supplementation increases MPOD, this provides a rationale for supplementation of the macular pigments in patients with AMD, although long-term clinical outcome data are lacking.
Collapse
Affiliation(s)
- Semira Kaya
- Department of Clinical Pharmacology, Medical University of Vienna, Austria
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Macular pigment density changes in Japanese individuals supplemented with lutein or zeaxanthin: quantification via resonance Raman spectrophotometry and autofluorescence imaging. Jpn J Ophthalmol 2012; 56:488-96. [PMID: 22699751 DOI: 10.1007/s10384-012-0157-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2011] [Accepted: 03/26/2012] [Indexed: 10/28/2022]
Abstract
PURPOSE Our purpose was to determine whether either lutein or zeaxanthin supplementation affects macular pigment concentration/optical density (MPOD) in healthy Japanese individuals. METHODS Twenty-two healthy volunteers were randomized to either 10 mg of orally administered lutein or zeaxanthin daily for up to 3 months. MPOD levels were measured by resonance Raman spectrophotometry (RRS) and one-wavelength autofluorescence imaging (AFI) at baseline and 1, 2, and 3 months after the start of supplementation. RESULTS MPOD levels measured with each method were correlated significantly at all time points. MPOD(RRS) and MPOD(AFI) levels increased >20 % from baseline at 2 and 3 months after lutein supplementation. By multiple regression analyses, the refractive error was correlated positively with MPOD(RRS) levels at baseline, whereas age and sex were not significant. In the lutein group, MPOD(RRS) levels significantly increased from baseline at all time points in individuals without high myopia exceeding -4 diopters, whereas the increase was not observed in individuals with high myopia. In the zeaxanthin group, MPOD(RRS) levels remained unchanged in those with and without high myopia. CONCLUSIONS MPOD(RRS) and MPOD(AFI) levels correlated significantly with each other. In normal healthy Japanese individuals without high myopia, lutein supplementation increased MPOD levels within the fovea more effectively than did zeaxanthin.
Collapse
|
26
|
Kijlstra A, Tian Y, Kelly ER, Berendschot TTJM. Lutein: more than just a filter for blue light. Prog Retin Eye Res 2012; 31:303-15. [PMID: 22465791 DOI: 10.1016/j.preteyeres.2012.03.002] [Citation(s) in RCA: 178] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2012] [Revised: 03/05/2012] [Accepted: 03/09/2012] [Indexed: 12/15/2022]
Abstract
Lutein is concentrated in the primate retina, where together with zeaxanthin it forms the macular pigment. Traditionally lutein is characterized by its blue light filtering and anti-oxidant properties. Eliminating lutein from the diet of experimental animals results in early degenerative signs in the retina while patients with an acquired condition of macular pigment loss (Macular Telangiectasia) show serious visual handicap indicating the importance of macular pigment. Whether lutein intake reduces the risk of age related macular degeneration (AMD) or cataract formation is currently a strong matter of debate and abundant research is carried out to unravel the biological properties of the lutein molecule. SR-B1 has recently been identified as a lutein binding protein in the retina and this same receptor plays a role in the selective uptake in the gut. In the blood lutein is transported via high-density lipoproteins (HDL). Genes controlling SR-B1 and HDL levels predispose to AMD which supports the involvement of cholesterol/lutein transport pathways. Apart from beneficial effects of lutein intake on various visual function tests, recent findings show that lutein can affect immune responses and inflammation. Lutein diminishes the expression of various ocular inflammation models including endotoxin induced uveitis, laser induced choroidal neovascularization, streptozotocin induced diabetes and experimental retinal ischemia and reperfusion. In vitro studies show that lutein suppresses NF kappa-B activation as well as the expression of iNOS and COX-2. Since AMD has features of a chronic low-grade systemic inflammatory response, attention to the exact role of lutein in this disease has shifted from a local effect in the eye towards a possible systemic anti-inflammatory function.
Collapse
Affiliation(s)
- Aize Kijlstra
- University Eye Clinic Maastricht, Maastricht, The Netherlands.
| | | | | | | |
Collapse
|
27
|
Panorgias A, Kulikowski JJ, Parry NRA, McKeefry DJ, Murray IJ. The relationship between peripherally matched invariant hues and unique hues: a cone-contrast approach. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2012; 29:A233-A239. [PMID: 22330384 DOI: 10.1364/josaa.29.00a233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A characteristic shift in hue and saturation occurs when colored targets are viewed peripherally compared with centrally. Four hues, one in each of the red, blue, green, and yellow regions of color space, remain unchanged when presented in the peripheral field. Apart from green, these peripherally invariant hues correspond almost exactly in color space with the unique hues. We explore this puzzling observation using asymmetric color-matching and color-naming experiments and computing cone contrasts for peripheral and central stimuli. We find that the difference between cone contrasts for the peripheral and central stimuli reaches a maximum at the chromatic axis corresponding to peripherally invariant green. We speculate that the effect is linked to a weakened signal from M-cones and probably associated with a reduced number of M-cones in peripheral retina.
Collapse
Affiliation(s)
- Athanasios Panorgias
- Faculty of Life Sciences, Carys Bannister Building, The University of Manchester, Manchester M13 9PT, UK.
| | | | | | | | | |
Collapse
|
28
|
Fawzi AA, Lee N, Acton JH, Laine AF, Smith RT. Recovery of macular pigment spectrum in vivo using hyperspectral image analysis. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:106008. [PMID: 22029355 PMCID: PMC3206925 DOI: 10.1117/1.3640813] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 08/23/2011] [Accepted: 08/30/2011] [Indexed: 05/20/2023]
Abstract
We investigated the feasibility of a novel method for hyperspectral mapping of macular pigment (MP) in vivo. Six healthy subjects were recruited for noninvasive imaging using a snapshot hyperspectral system. The three-dimensional full spatial-spectral data cube was analyzed using non-negative matrix factorization (NMF), wherein the data was decomposed to give spectral signatures and spatial distribution, in search for the MP absorbance spectrum. The NMF was initialized with the in vitro MP spectrum and rank 4 spectral signature decomposition was used to recover the MP spectrum and optical density in vivo. The recovered MP spectra showed two peaks in the blue spectrum, characteristic of MP, giving a detailed in vivo demonstration of these absorbance peaks. The peak MP optical densities ranged from 0.08 to 0.22 (mean 0.15+∕-0.05) and became spatially negligible at diameters 1100 to 1760 μm (4 to 6 deg) in the normal subjects. This objective method was able to exploit prior knowledge (the in vitro MP spectrum) in order to extract an accurate in vivo spectral analysis and full MP spatial profile, while separating the MP spectra from other ocular absorbers. Snapshot hyperspectral imaging in combination with advanced mathematical analysis provides a simple cost-effective approach for MP mapping in vivo.
Collapse
Affiliation(s)
- Amani A Fawzi
- University of Southern California, Doheny Eye Institute, Keck School of Medicine, Department of Ophthalmology, 1450 San Pablo Ave, Suite 3614, Los Angeles, California 90033, USA
| | | | | | | | | |
Collapse
|
29
|
Howells O, Eperjesi F, Bartlett H. Measuring macular pigment optical density in vivo: a review of techniques. Graefes Arch Clin Exp Ophthalmol 2011; 249:315-47. [PMID: 21221629 DOI: 10.1007/s00417-010-1577-5] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2010] [Revised: 11/04/2010] [Accepted: 11/15/2010] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Macular pigment has been the focus of much attention in recent years, as a potential modifiable risk factor for age-related macular degeneration. This interest has been heightened by the ability to measure macular pigment optical density (MPOD) in vivo. METHOD A systematic literature search was undertaken to identify all available papers that have used in vivo MPOD techniques. The papers were reviewed, and all relevant information was incorporated into this article. RESULTS Measurement of MPOD is achievable with a wide range of techniques, which are typically categorized into one of two groups: psychophysical (requiring a response from the subject) or objective (requiring minimal input from the subject). The psychophysical methods include heterochromatic flicker photometry and minimum motion photometry. The objective methods include fundus reflectometry, fundus autofluorescence, resonance Raman spectroscopy and visual evoked potentials. Even within the individual techniques, there is often much variation in how data is obtained and processed. CONCLUSION This review comprehensively details the procedure, instrumentation, assumptions, validity and reliability of each MPOD measurement technique currently available, along with their respective advantages and disadvantages. This leads us to conclude that development of a commercial instrument, based on fundus reflectometry or fundus autofluorescence, would be beneficial to macular pigment research and would support MPOD screening in a clinical setting.
Collapse
Affiliation(s)
- Olivia Howells
- Ophthalmic Research Group, School of Life and Health Sciences, Aston University, Birmingham, B4 7ET, UK.
| | | | | |
Collapse
|
30
|
Berendschot TTJM, van de Kraats J, Kanis MJ, van Norren D. Directional model analysis of the spectral reflection from the fovea and para-fovea. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:065005. [PMID: 21198169 DOI: 10.1117/1.3523370] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Directional and nondirectional spectral reflection data from 0, 1, 2, 4, and 8 deg eccentricity, and the optic disk, were analyzed from 400 to 950 nm with an existing optical reflection model. The optical model, developed for the fovea, appeared to be also suitable for more eccentric locations. The optical densities of melanin and of the macular pigments zeaxanthin and lutein peaked in the fovea, in correspondence with literature data. The amplitude of the directional component, originating in the cone photoreceptors, had its maximum at 1 deg. The maximum of the directionality (peakedness) occurred at a slightly higher eccentricity.
Collapse
|