1
|
Fonager SV, Winther G, Wittenborn TR, Jensen L, Fahlquist-Hagert C, Hansen LA, Füchtbauer EM, Romero-Ramos M, Degn SE. Increased maternofoetal transfer of antibodies in a murine model of systemic lupus erythematosus, but no immune activation and neuroimmune sequelae in offspring. J Neuroimmunol 2022; 370:577927. [PMID: 35858501 DOI: 10.1016/j.jneuroim.2022.577927] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 05/27/2022] [Accepted: 07/09/2022] [Indexed: 10/17/2022]
Abstract
Maternally transferred autoantibodies can negatively impact the development and health of offspring, increasing the risk of neurodevelopmental disorders. We used embryo transfers to examine maternofoetal immune imprinting in the autoimmune BXSB/MpJ mouse model. Anti-double-stranded DNA antibodies and total immunoglobulins were measured, using allotypes of the IgG subclass to distinguish maternally transferred antibodies from those produced endogenously. Frequencies of germinal center and plasma cells were analysed by flow cytometry. Microglial morphology in offspring CNS was assessed using immunohistochemistry. In contrast to prior findings, our results indicate that BXSB/MpJ mothers display a mild autoimmune phenotype, which does not significantly impact the offspring.
Collapse
Affiliation(s)
- Sofie Vestergaard Fonager
- Department of Biomedicine, Aarhus University, Denmark; Department of Molecular Biology and Genetics, Aarhus University, Denmark
| | | | | | | | | | | | | | - Marina Romero-Ramos
- Department of Biomedicine, Aarhus University, Denmark; DANDRITE, Danish Research Institute of Translational Neuroscience, Aarhus University, 8000, Aarhus C, Denmark
| | | |
Collapse
|
2
|
Koefoed-Nielsen P, Bistrup C, Christiansen M. Protein a Immunoadsorption May Hamper the Decision to Transplant Due to Interference With CDC Crossmatch Results. J Clin Apher 2016; 32:163-169. [PMID: 27258774 DOI: 10.1002/jca.21476] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Accepted: 05/16/2016] [Indexed: 11/10/2022]
Abstract
Transplanting immunized patients requires immunological monitoring in the pretransplant phase to follow reduction of donor specific HLA antibodies (DSA) after Staphylococcus aureus protein A (SPA) immunoadsorption (IA) or therapeutic plasma exchange followed by IVIG and Rituximab administration. Pretreatment aims to significantly reduce DSA strength. The Tissue Typing Lab at Aarhus University Hospital performs immunological monitoring of approximately 150 kidney transplantation patients per year from two transplant centers. From 2012 to 2013, we experienced seven patients desensitized using SPA IA, initially presenting negative cytotoxic complement dependent (CDC) T-cell crossmatches but positive B and T cell flowcytometric crossmatch, who despite significant DSA reduction developed weakly positive CDC T-cell crossmatch shortly prior to transplantation. We hypothesised that leached SPA during IA could be the cause, as the complication was not observed in patients who received plasma exchanges. We found that the positive CDC was not donor specific and SPA column material incubated with control serum reproduced a positive CDC T-cell crossmatch. Finally, we detected leached SPA in one of the patient samples using a highly sensitive time-resolved fluorescent assay. In conclusion, the results emphasize the importance of carefully considering CDC crossmatch results subsequent to IA, before a planned transplantation is either postponed or cancelled. J. Clin. Apheresis 32:163-169, 2017. © 2016 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
| | - Claus Bistrup
- Department of Nephrology, Odense University Hospital, Odense, Denmark
| | - Mette Christiansen
- Department of Clinical Immunology, Aarhus University Hospital, Aarhus N, Denmark
| |
Collapse
|
3
|
Salminen T, Juntunen E, Khanna N, Pettersson K, Talha SM. Anti-HCV immunoassays based on a multiepitope antigen and fluorescent lanthanide chelate reporters. J Virol Methods 2015; 228:67-73. [PMID: 26615808 DOI: 10.1016/j.jviromet.2015.11.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Revised: 11/05/2015] [Accepted: 11/06/2015] [Indexed: 02/06/2023]
Abstract
There is a need for simple to produce immunoassays for hepatitis C virus (HCV) antibody capable of detecting all genotypes worldwide. Current commonly used third generation immunoassays use three to six separate recombinant proteins or synthetic peptides. We have developed and expressed in Escherichia coli a single recombinant antigen incorporating epitopes from different HCV proteins. This multiepitope protein (MEP) was used to develop two types of HCV antibody immunoassays: a traditional antibody immunoassay using a labeled secondary antibody (indirect assay) and a double-antigen assay with the same MEP used as capture binder and labeled binder. The secondary antibody assay was evaluated with 171 serum/plasma samples and double-antigen assay with 148 samples. These samples included an in-house patient sample panel, two panels of samples with different HCV genotypes and a seroconversion panel. The secondary antibody immunoassay showed 95.6% sensitivity and 100% specificity while the double-antigen assay showed 91.4% sensitivity and 100% specificity. Both assays detected samples from all six HCV genotypes. The results showed that combining a low-cost recombinant MEP binder antigen with a high sensitivity fluorescent lanthanide reporter can provide a sensitive and specific immunoassay for HCV serology. The results also showed that the sensitivity of HCV double-antigen assays may suffer from the low avidity immune response of acute infections.
Collapse
Affiliation(s)
- Teppo Salminen
- Department of Biotechnology, University of Turku, Turku, Finland.
| | - Etvi Juntunen
- Department of Biotechnology, University of Turku, Turku, Finland
| | - Navin Khanna
- Recombinant Gene Products Group, International Centre for Genetic Engineering & Biotechnology, Aruna Asaf Ali Marg, New Delhi, India; Translational Health Science & Technology Institute, NCR Biotech Science Cluster, Faridabad, India; Department of Paediatrics, Emory University School of Medicine, Atlanta, GA, USA
| | - Kim Pettersson
- Department of Biotechnology, University of Turku, Turku, Finland
| | - Sheikh M Talha
- Department of Biotechnology, University of Turku, Turku, Finland
| |
Collapse
|
4
|
Talha SM, Nemani SK, Salminen T, Kumar S, Swaminathan S, Soukka T, Pettersson K, Khanna N. Escherichia coli-expressed near full length HIV-1 envelope glycoprotein is a highly sensitive and specific diagnostic antigen. BMC Infect Dis 2012. [PMID: 23186021 PMCID: PMC3519745 DOI: 10.1186/1471-2334-12-325] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Background The Human Immunodeficiency Virus type 1 (HIV-1) envelope glycoprotein gp160, useful in detecting anti-HIV-1 antibodies, is difficult to express in heterologous hosts. The major hurdles are its signal sequence, strong hydrophobic regions and heavy glycosylation. While it has not been possible to express full length recombinant (r)-gp160 in E. coli, it can be expressed in insect and mammalian cells, but at relatively higher cost. In this work, we report E. coli-based over-expression of r-gp160 variant and evaluate its performance in diagnostic immunoassays for the detection of anti-HIV-1 antibodies. Methods A deletion variant of r-gp160 lacking hydrophobic regions of the parent full length molecule was expressed in E. coli and purified to near homogeneity using single-step Ni(II)-affinity chromatography. Biotinylated and europium(III) chelate-labeled versions of this antigen were used to set up one- and two-step time-resolved fluorometric double antigen sandwich assays. The performance of these assays was evaluated against a collection of well-characterized human sera (n=131), that included an in-house panel and four commercially procured panels. Results In-frame deletion of three hydrophobic regions, spanning amino acid residues 1–43, 519–538 and 676–706, of full length HIV-1 gp160 resulted in its expression in E. coli. Both the one- and two-step assays manifested high sensitivity unambiguously identifying 75/77 and 77/77 HIV-1 positive sera, respectively. Both assays also identified all 52 HIV-seronegative sera correctly. Between the two assays, the mean signal-to-cutoff value of the two-step assay was an order of magnitude greater than that of the one-step assay. Both assays were highly specific manifesting no cross-reactivity towards antibodies specific to other viruses like hepatitis B, C, and human T cell leukemia viruses. Conclusions This study has demonstrated the expression of r-gp160 variant in E. coli, by deletion of hydrophobic regions, and its purification in reasonable yields. This underscores the potential for cost saving in antigen production. Evaluation of this antigen in a double antigen sandwich two-step assay showed it to be a highly sensitive and specific HIV-1 diagnostic reagent. The amenability of this assay to the one-step format suggests its potential utility in developing a rapid point-of-care HIV-1 diagnostic test.
Collapse
Affiliation(s)
- Sheikh M Talha
- Department of Biotechnology, University of Turku, 20520 Turku, Finland.
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Bernth-Jensen JM, Møller BK, Jensenius JC, Thiel S. Biological variation of anti-αGal-antibodies studied by a novel Time-Resolved ImmunoFluorometric Assay. J Immunol Methods 2011; 373:26-35. [DOI: 10.1016/j.jim.2011.07.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2011] [Revised: 07/04/2011] [Accepted: 07/18/2011] [Indexed: 10/17/2022]
|
6
|
Talha SM, Salminen T, Swaminathan S, Soukka T, Pettersson K, Khanna N. A highly sensitive and specific time resolved fluorometric bridge assay for antibodies to HIV-1 and -2. J Virol Methods 2011; 173:24-30. [PMID: 21232554 DOI: 10.1016/j.jviromet.2011.01.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2010] [Revised: 12/20/2010] [Accepted: 01/04/2011] [Indexed: 11/28/2022]
Abstract
This study addresses the continuing need to develop human immunodeficiency virus-1 (HIV-1) and HIV-2 immunoassays with increased sensitivity. Two chimeric antigens, r-HIV-1env, incorporating immunoreactive regions of HIV-1 glycoprotein (gp) 120 and gp41, and r-HIV-2env, incorporating HIV-2 gp125 and gp36, and their corresponding in vivo biotinylated versions, r-Bio-HIV-1env and r-Bio-HIV-2env, were expressed in Escherichia coli and purified by single step affinity chromatography. These antigens were used to set up a bridge assay for the detection of anti-HIV antibodies. Anti-HIV-1 and HIV-2 antibodies in sera were captured using a mixture of the biotinylated antigens, immobilized on streptavidin-coated microtiter wells, and revealed using a mixture of the non-biotinylated antigens, labeled with either Eu(3+) chelate or with nanoparticles doped with the Eu(3+) chelate, followed by fluorescence measurement using time resolved fluorometry (TRF). The performance of this TRF immunoassay was compared to that of five commercial HIV ELISAs using well-characterized sera panels. The results show that the TRF immunoassay using either form of the label was in complete agreement with the commercial assays. The use of the Eu(3+) chelate label enhanced sensitivity significantly when used in the nanoparticle format as evidenced by the very high signal-to-cut-off ratios.
Collapse
Affiliation(s)
- Sheikh M Talha
- International Centre for Genetic Engineering & Biotechnology, Aruna Asaf Ali Marg, New Delhi 110067, India
| | | | | | | | | | | |
Collapse
|
7
|
A novel antibody avidity methodology for rapid point-of-care serological diagnosis. J Virol Methods 2010; 166:86-91. [DOI: 10.1016/j.jviromet.2010.02.028] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2009] [Revised: 02/21/2010] [Accepted: 02/25/2010] [Indexed: 11/20/2022]
|
8
|
Koskinen JO, Vaarno J, Vainionpää R, Meltola NJ, Soini AE. A novel separation-free assay technique for serum antibodies using antibody bridging assay principle and two-photon excitation fluorometry. J Immunol Methods 2005; 309:11-24. [PMID: 16387323 DOI: 10.1016/j.jim.2005.10.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2005] [Revised: 10/03/2005] [Accepted: 10/27/2005] [Indexed: 11/30/2022]
Abstract
A new technique for separation-free detection of antigen-specific antibodies is presented. The new technique employs antibody bridging assay principle and the recently developed ArcDia TPX fluorescence detection technology. According to the assay scheme, antibody molecules from the sample bind with one arm to an antigen on polymer microspheres and with the other arm to a fluorescently labeled secondary antigen reagent. Consequently, fluorescent immunocomplexes are formed on the surface of microspheres in proportion to the concentration of the analyte in the sample. The fluorescence signal from individual microspheres is measured by means of two-photon excited fluorescence detection. In order to demonstrate the applicability of the new assay technique, an assay for anti-adenovirus antibodies was constructed. The function of the assay method was tested both with monoclonal anti-adenovirus antibody preparation (standard analyte), and with positive serum samples. Standard class-specific ELISA was used as a reference method. The new assay method provides comparable sensitivity and precision, and wider dynamic range for IgG antibodies than the ELISA method. The standard curve showed linear response (R(2)=0.999) with a dynamic range of three orders of magnitude, detection limit (mean+3S.D.) of 8 pM, and intra-assay signal precision of 5%. Applicability of the new method for clinical serodiagnostics is discussed.
Collapse
Affiliation(s)
- Janne O Koskinen
- Laboratory of Biophysics, Institute of Biomedicine, University of Turku, Finland
| | | | | | | | | |
Collapse
|
9
|
Ankelo M, Westerlund-Karlsson A, Ilonen J, Knip M, Savola K, Kankaanpää P, Meriö L, Siitari H, Hinkkanen A. Time-resolved fluorometric assay for detection of autoantibodies to glutamic acid decarboxylase (GAD65). Clin Chem 2003; 49:908-15. [PMID: 12765987 DOI: 10.1373/49.6.908] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Type 1 diabetes mellitus results from destruction of the pancreatic insulin-producing beta cells by a chronic autoimmune process. Methods are needed for the detection of circulating autoantibodies to glutamic acid decarboxylase (GAD65), a major marker of this process. METHODS Streptavidin-coated microtiter plates were incubated with biotinylated GAD65, and after incubation with serum samples from patients with type 1 diabetes mellitus and control individuals, europium-labeled GAD65 was added. After washing steps, the delayed fluorescence was measured in duplicate in a fluorometer. Samples collected from 100 patients with newly diagnosed type 1 diabetes mellitus and 100 healthy controls were measured by the new assay and by a radiobinding assay. RESULTS The detection limit of the new assay was 1.49 WHO units/mL, the calibration curve was linear to 4140 WHO units/mL, and no hook effect was observed up to 41,400 WHO units/mL. The intraassay CV was 2.1-6.3% over the calibration range. For patient serum samples, the intraassay, interassay, and total CVs were 5.4-7.0%, 9.8-13%, and 12-14%, respectively. Compared with conventional radioimmunologic methods, the analytical range was broader and the analysis time required to perform the measurements was shorter. At a cutoff with 99% specificity, the new assay and the radiobinding assay were positive in 71 and 67 patients, respectively. CONCLUSIONS The new assay provides a rapid and sensitive nonradioactive method applicable for large-scale screening for beta-cell autoimmunity. It has a broad linear analytical range, is easy to perform and automate, and has sensitivity and specificity comparable to those for the conventional radioisotope assay.
Collapse
Affiliation(s)
- Matti Ankelo
- Department of Biochemistry and Pharmacy, Abo Akademi University, FIN-20521 Turku, Finland.
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
McKie A, Vyse A, Maple C. Novel methods for the detection of microbial antibodies in oral fluid. THE LANCET. INFECTIOUS DISEASES 2002; 2:18-24. [PMID: 11892490 DOI: 10.1016/s1473-3099(01)00169-4] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Compared with blood, oral fluid has several advantages as a sample for antibody detection. It is simple, safe, painless, and cheap to collect. The only drawback is that while the antibody profiles indicate those in blood, they are at lower concentrations. Antibody capture assays are the method of choice for the detection of microbial antibodies in oral fluid, but their relative lack of sensitivity when based on conventional immunoassay techniques has mostly limited their use to epidemiological applications. Immuno-PCR and time-resolved fluorescence offer more sensitive detection systems that could be applied to oral fluid specimens. We review antibody detection in oral fluid and discuss immuno-PCR and time-resolved fluorescence as candidate systems. Both have the potential to broaden the applications of oral fluid testing to clinical diagnostics.
Collapse
Affiliation(s)
- Anne McKie
- Virus Reference Division, Central Public Health Laboratory, 61 Colindale Avenue, London NW9 5HT, UK.
| | | | | |
Collapse
|
11
|
Mehto P, Ankelo M, Hinkkanen A, Mikhailov A, Eriksson JE, Spoof L, Meriluoto J. A time-resolved fluoroimmunometric assay for the detection of microcystins, cyanobacterial peptide hepatotoxins. Toxicon 2001; 39:831-6. [PMID: 11137543 DOI: 10.1016/s0041-0101(00)00215-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
An immunoassay based on the time-resolved fluorometry (TR-FIA) was developed for microcystins, cyanobacterial peptide hepatotoxins. The assay was performed in a competitive mode and it utilised the monoclonal antibodies raised against microcystin-LR, and a europium chelate of microcystin-LR as a competitive antigen. The sensitivity of the assay was 0.1microg/l. The detection method of TR-FIA was compared to a commercially available kit based on the enzyme-linked immunosorbent assay (ELISA). The same level of sensitivity could be obtained with TR-FIA (in a non-optimised system). The simplified method of TR-FIA leads to a shorter analysis time.
Collapse
Affiliation(s)
- P Mehto
- Department of Biochemistry and Pharmacy, Abo Akademi University, P.O. Box 66, 20521 Turku, Finland
| | | | | | | | | | | | | |
Collapse
|
12
|
Paugam A, Sarfati J, Romieu R, Viguier M, Dupouy-Camet J, Latgé JP. Detection of Aspergillus galactomannan: comparison of an enzyme-linked immunoassay and a europium-linked time-resolved fluoroimmunoassay. J Clin Microbiol 1998; 36:3079-80. [PMID: 9738075 PMCID: PMC105119 DOI: 10.1128/jcm.36.10.3079-3080.1998] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
With a view to improving the sensitivity of serological detection of Aspergillus galactomannan (GM), a europium-linked time-resolved fluoroimmunoassay was developed. This method was compared to an enzyme-linked immunosorbent assay using a peroxidase-conjugated detector antibody. No increase in the sensitivity of the detection of GM standards was seen with the europium-based fluoroimmunoassay.
Collapse
Affiliation(s)
- A Paugam
- Laboratoire de Mycologie, Hôpital Cochin, Paris, France.
| | | | | | | | | | | |
Collapse
|
13
|
Aggerbeck H, Nørgaard-Pedersen B, Heron I. Simultaneous quantitation of diphtheria and tetanus antibodies by double antigen, time-resolved fluorescence immunoassay. J Immunol Methods 1996; 190:171-83. [PMID: 8621952 DOI: 10.1016/0022-1759(95)00270-7] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
A dual, double antigen, time-resolved fluorescence immunoassay (DELFIA) for the simultaneous detection and quantitation of diphtheria (D) and tetanus (T) antibodies in sera has been developed. In the double antigen format one arm of the antibody binds to antigen coated microtitre wells and the other arm binds to labelled antigen to provide a fluorescent signal. This assay was found to be functionally specific for IgG antibodies and showed a good correlation with established toxin neutralization assays. Furthermore, the double antigen set-up was species independent, permitting the direct use of existing international references of animal origin to measure protective antibody levels in humans in international units (IU/ml). The detection limit corresponded to 0.0003 IU/ml with Eu(3+)-labelled toxoids and to 0.0035 IU/ml using Sm(3+)-labelled toxoids. The assay was fast with a high capacity making it a suitable method for serological surveillance studies.
Collapse
Affiliation(s)
- H Aggerbeck
- Statens Seruminstitut, Bacterial Vaccine Department, Copenhagen, Denmark
| | | | | |
Collapse
|
14
|
Schmidt M, Lindqvist C, Salmi A, Oker-Blom C. Detection of rubella virus-specific immunoglobulin M antibodies with a baculovirus-expressed E1 protein. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 1996; 3:216-8. [PMID: 8991639 PMCID: PMC170281 DOI: 10.1128/cdli.3.2.216-218.1996] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The structural proteins of rubella virus (RV) were expressed in insect cells by using the baculovirus expression vector system. The recombinant E1 envelope glycoprotein was purified by immunoaffinity chromatography and used to detect RV-specific immunoglobulin M antibodies in a time-resolved fluoroimmunoassay. Correlation analysis between the reactivities of antibodies against this recombinant E1 and the reactivities against authentic RV antigen shows that purified E1 can detect RV antibodies of the immunoglobulin M type.
Collapse
Affiliation(s)
- M Schmidt
- Department of Biochemistry and Pharmacy, Abo Akademi University, Turku, Finland
| | | | | | | |
Collapse
|
15
|
Dickson EF, Pollak A, Diamandis EP. Ultrasensitive bioanalytical assays using time-resolved fluorescence detection. Pharmacol Ther 1995; 66:207-35. [PMID: 7667396 DOI: 10.1016/0163-7258(94)00078-h] [Citation(s) in RCA: 107] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
This article reviews the use of time-resolved fluorimetric detection of lanthanide chelate luminescence as a detection method for ultrasensitive bioanalytical assays. Assay formats and detection methods, and the principle of time-resolved fluorimetric detection, are described. Detection systems, assay formats, reagents, and instrumentation for time-resolved fluorimetric detection are outlined. A review of published and commercially available immunoassays and DNA hybridization assays using time-resolved fluorimetric detection of lanthanide chelate luminescence is given.
Collapse
Affiliation(s)
- E F Dickson
- Department of Chemistry and Chemical Engineering, Royal Military College of Canada, Kingston, Ontario
| | | | | |
Collapse
|
16
|
|
17
|
Osborne S, Cecconato E, Griva S, Garetto F, Calogero R, Rosa C, Bonelli F. Expression in E. coli and purification of a chimeric p22-NS3 recombinant antigen of hepatitis C virus (HCV). FEBS Lett 1993; 324:253-7. [PMID: 8405360 DOI: 10.1016/0014-5793(93)80128-h] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A recombinant antigen (p22-NS3), possessing putative HCV nucleocapsid protein (p22) and non-structural protein 3 (NS3) epitopes, was heavily expressed in E. coli and purified. The p22-NS3 purified recombinant antigen strongly reacts with sera containing human antibodies directed against p22 and NS3 providing a starting point for the design of an HCV single all-encompassing antigen for a blood screening assay.
Collapse
Affiliation(s)
- S Osborne
- R&D Diagnostic Division, SORIN Biomedica S.p.A., Saluggia, Italy
| | | | | | | | | | | | | |
Collapse
|
18
|
Lombardi V, Caniglia M, Scarlatti G, Jansson M, Plebani A, D'Argenio P, Scaccia S, Wigzell H, Rossi P. Early detection of IgA specific antibodies in HIV-1 infected children by peptide-ELISA and peptide time-resolved fluoro-immunoassay. Eur J Pediatr 1993; 152:484-9. [PMID: 8335015 DOI: 10.1007/bf01955055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
The presence of specific IgA antibodies in sera from 25 infants born to HIV-1 seropositive mothers was investigated by peptide-ELISA and peptide time-resolved fluoro-immunoassay (TR-FIA). The infants had been monitored at different times after birth for clinical signs and/or symptoms of HIV-1 infection and for detection of HIV-1 in lymphocyte cultures. Serum samples had also been tested for HIV-1 IgG antibodies by commercial ELISA and Western blot and for p24 antigen. Eleven of 25 children were then identified as infected. IgA detection was performed after rProtein G treatment to remove interfering IgG. In the infected group, IgA specific antibodies to a synthetic peptide representing a highly conserved region of the transmembrane glycoprotein gp41 (env: 594-613) were detected in 27 (73%) out of 37 serum samples (9 of 11 children) by the peptide-ELISA test. IgA specific antibodies to the same peptide were found in 30 (81%) sera (9 of 11 children) by the peptide-TR-FIA. Specific HIV-1 IgA antibodies were detected as early as 2 months of age in serum samples from five out of seven children (71% sensitivity) using peptide-ELISA and from six out of seven (86% sensitivity) by peptide-TR-FIA. Conversely, IgA specific antibodies to HIV-1 were absent in two infected children as well as in the sera of all uninfected children tested during the follow up period. Since maternal IgA does not cross the placenta, IgA detection in the serum of the infant is indicative of HIV-1 infection.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- V Lombardi
- Department of Immunology, Karolinska Institute, Stockholm, Sweden
| | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Leinikki P, Lehtinen M, Hyöty H, Parkkonen P, Kantanen ML, Hakulinen J. Synthetic peptides as diagnostic tools in virology. Adv Virus Res 1993; 42:149-86. [PMID: 7679241 DOI: 10.1016/s0065-3527(08)60085-8] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- P Leinikki
- HIV Laboratory, National Public Health Institute, Helsinki, Finland
| | | | | | | | | | | |
Collapse
|
20
|
Lan SJ, Hsieh CC, Yen YY. Pooling Strategies for Screening Blood in Areas with Low Prevalence of HIV. Biom J 1993. [DOI: 10.1002/bimj.4710350505] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
21
|
Ko YC, Lan SJ, Chiang TA, Yen YY, Hsieh CC. Successful use of pooled sera to estimate HIV antibody seroprevalence and eliminate all positive cases. Asia Pac J Public Health 1992; 6:146-9. [PMID: 1342802 DOI: 10.1177/101053959200600305] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Pooling specimens when testing them in large numbers can save scarce resources and several earlier reports have indicated this to be a feasible strategy. In an HIV antibody mass screening test carried out in our laboratory, we used Dorfman's two-stage model. We sought to establish the optimal number of specimens in a pool, and to achieve maximum efficiency while maintaining both sensitivity and specificity. Before testing for HIV antibody, five positive samples were placed in a set of 1012 sera in a double blind manner, one positive sample into a second set of 1012 sera and none in a third set. The positive rate was assumed to be 0.2% for each set of 1012 sera. As indicated by our model, 22 individual serum samples were placed into each of 46 pools which, when tested by particle agglutination assays, lead to the identification of all positive samples. We concluded that the prevalence rate can be estimated in the first stage, 95% confidence intervals were given, and the efficiency rate could be calculated for the identification of all infected specimens in a large number of samples showing low prevalence rates.
Collapse
Affiliation(s)
- Y C Ko
- School of Public Health and Graduate Institute of Medicine, Kaohsiung Medical College, Taiwan, ROC
| | | | | | | | | |
Collapse
|
22
|
Lombardi VR, Libonatti O, Alimandi M, Ansotegui I, Scarlatti G, Moschese V, Wigzell H, Rossi P. Detection of antibodies to human immunodeficiency virus type I by using synthetic peptides and time-resolved fluoroimmunoassay (TR-FIA). Eur J Epidemiol 1992; 8:298-304. [PMID: 1644152 DOI: 10.1007/bf00144818] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A simple, rapid, reproducible and sensitive peptide-Time-Resolved-Fluoroimmunoassay (TR-FIA) method is described which allows the detection of antibodies to the Human Immunodeficiency Virus type 1 (HIV-1). By using a panel of synthetic peptide antigens that covered env, gag and pol amino acid sequences, a 20 amino acid peptide (GIWGCSGKLICTTAVPWNAS) describing an immunodominant and conserved domain on the gp41 region of the BH10 clone was found to be the most reactive in this study. Optimal conditions for antigen concentration, serum dilution and incubation time were established. The peptide-TR-FIA is specific, as assessed by testing HIV-1 positive sera which included samples from AIDS, ARC patients and HIV-positive drug users. The test was used to detect HIV antibodies in 250 well characterized HIV-1 positive sera and 50 normal sera. Peptide-TR-FIA results indicate that the env peptide was highly reactive with HIV-positive sera showing a sensitivity of 100%. None of the 50 control sera showed positive reactivity against the synthetic peptide. Furthermore the peptide-TR-FIA allowed a fine titration of antibodies to defined epitopes of immunodominant HIV structural proteins that usually cannot be achieved by peptide-ELISA assays.
Collapse
Affiliation(s)
- V R Lombardi
- Dpt. of Immunology, Karolinska Institute, Stockholm, Sweden
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Zanoni RG, Nauta IM, Pauli U, Peterhans E. Expression in Escherichia coli and sequencing of the coding region for the capsid protein of Dutch maedi-visna virus strain ZZV 1050: application of recombinant protein in enzyme-linked immunosorbent assay for the detection of caprine and ovine lentiviruses. J Clin Microbiol 1991; 29:1290-4. [PMID: 1653261 PMCID: PMC270102 DOI: 10.1128/jcm.29.7.1290-1294.1991] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Maedi-visna in sheep and caprine arthritis-encephalitis in goats are caused by two closely related and widespread lentiviruses. The infections are characterized by life-long virus persistence and slow induction of antiviral antibodies. The diagnosis is based on the detection of antiviral antibodies. We have used the polymerase chain reaction (PCR) to amplify a part of the gag gene coding for the entire capsid protein and for parts of the matrix and nucleocapsid proteins. Sequencing of the PCR fragment of the Dutch maedi-visna virus strain ZZV 1050 revealed 85 and 92% homology to the DNA and deduced amino acid sequences, respectively, of the distantly related Icelandic visna virus strain 1514. The respective homologies with caprine arthritis-encephalitis virus strain CO were 76 and 80%. The PCR fragment was cloned into pGEX-2T and expressed as a glutathione S-transferase fusion protein. The recombinant protein could be detected on immunoblots by using a monoclonal antibody and polyclonal antisera and was further purified by glutathione-based affinity chromatography. Enzyme-linked immunosorbent assay with purified recombinant fusion protein is shown to be a sensitive and specific diagnostic tool for the detection of lentiviral infection in goats and sheep.
Collapse
Affiliation(s)
- R G Zanoni
- Institute of Veterinary Virology, Bern, Switzerland
| | | | | | | |
Collapse
|