1
|
Ferentinos P, Snape D, Koivula F, Faustini S, Nicholson-Little A, Stacey M, Gifford R, Parsons I, Lamb L, Greeves J, O'Hara J, Cunningham AF, Woods D, Richter A, O'Shea MK. Validation of dried blood spot sampling for detecting SARS-CoV-2 antibodies and total immunoglobulins in a large cohort of asymptomatic young adults. J Immunol Methods 2023; 518:113492. [PMID: 37201783 DOI: 10.1016/j.jim.2023.113492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 04/12/2023] [Accepted: 04/13/2023] [Indexed: 05/20/2023]
Abstract
BACKGROUND Detecting antibody responses following infection with SARS-CoV-2 is necessary for sero-epidemiological studies and assessing the role of specific antibodies in disease, but serum or plasma sampling is not always viable due to logistical challenges. Dried blood spot sampling (DBS) is a cheaper, simpler alternative and samples can be self-collected and returned by post, reducing risk for SARS-CoV-2 exposure from direct patient contact. The value of large-scale DBS sampling for the assessment of serological responses to SARS-CoV-2 has not been assessed in depth and provides a model for examining the logistics of using this approach to other infectious diseases. The ability to measure specific antigens is attractive for remote outbreak situations where testing may be limited or for patients who require sampling after remote consultation. METHODS We compared the performance of SARS-CoV-2 anti-spike and anti-nucleocapsid antibody detection from DBS samples with matched serum collected by venepuncture in a large population of asymptomatic young adults (N = 1070) living and working in congregate settings (military recruits, N = 625); university students, N = 445). We also compared the effect of self-sampling (ssDBS) with investigator-collected samples (labDBS) on assay performance, and the quantitative measurement of total IgA, IgG and IgM between DBS eluates and serum. RESULTS Baseline seropositivity for anti-Spike IgGAM antibody was significantly higher among university students than military recruits. Strong correlations were observed between matched DBS and serum samples in both university students and recruits for the anti-spike IgGAM assay. Minimal differences were found in results by ssDBS and labDBS and serum by Bland Altman and Cohen kappa analyses. LabDBS achieved 82.0% sensitivity and 98.2% specificity and ssDBS samples 86.1% sensitivity and 96.7% specificity for detecting anti-Spike IgGAM antibodies relative to serum samples. For anti-SARS-CoV-2 nucleocapsid IgG there was qualitatively 100% agreement between serum and DBS samples and weak correlation in ratio measurements. Strong correlations were observed between serum and DBS-derived total IgG, IgA, and IgM. CONCLUSIONS This is the largest validation of DBS against paired serum for SARS-CoV-2 specific antibody measurement and we have shown that DBS retains performance from prior smaller studies. There were no significant differences regarding DBS collection methods, suggesting that self-collected samples are a viable sampling collection method. These data offer confidence that DBS can be employed more widely as an alternative to classical serology.
Collapse
Affiliation(s)
- P Ferentinos
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK
| | - D Snape
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK
| | - F Koivula
- Department of Army Health and Performance Research, Andover, Hampshire, UK
| | - S Faustini
- Clinical Immunology Service, University of Birmingham, Birmingham, UK
| | - A Nicholson-Little
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK
| | - M Stacey
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK; Research & Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK
| | - R Gifford
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK; Research & Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK
| | - I Parsons
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK; Research & Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK
| | - L Lamb
- Research & Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK
| | - J Greeves
- Department of Army Health and Performance Research, Andover, Hampshire, UK
| | - J O'Hara
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK
| | - A F Cunningham
- Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham, UK
| | - D Woods
- Research Institute for Sport, Physical Activity and Leisure, Carnegie School of Sport, Leeds Beckett University, UK; Research & Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK
| | - A Richter
- Clinical Immunology Service, University of Birmingham, Birmingham, UK; Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham, UK
| | - M K O'Shea
- Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham, UK; Research & Clinical Innovation, Royal Centre for Defence Medicine, Birmingham, UK.
| |
Collapse
|
2
|
Baillargeon KR, Mace CR. Microsampling tools for collecting, processing, and storing blood at the point-of-care. Bioeng Transl Med 2023; 8:e10476. [PMID: 36925672 PMCID: PMC10013775 DOI: 10.1002/btm2.10476] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 11/29/2022] [Accepted: 12/07/2022] [Indexed: 01/01/2023] Open
Abstract
In the wake of the COVID-19 global pandemic, self-administered microsampling tools have reemerged as an effective means to maintain routine healthcare assessments without inundating hospitals or clinics. Finger-stick collection of blood is easily performed at home, in the workplace, or at the point-of-care, obviating the need for a trained phlebotomist. While the initial collection of blood is facile, the diagnostic or clinical utility of the sample is dependent on how the sample is processed and stored prior to transport to an analytical laboratory. The past decade has seen incredible innovation for the development of new materials and technologies to collect low-volume samples of blood with excellent precision that operate independently of the hematocrit effect. The final application of that blood (i.e., the test to be performed) ultimately dictates the collection and storage approach as certain materials or chemical reagents can render a sample diagnostically useless. Consequently, there is not a single microsampling tool that is capable of addressing every clinical need at this time. In this review, we highlight technologies designed for patient-centric microsampling blood at the point-of-care and discuss their utility for quantitative sampling as a function of collection material and technique. In addition to surveying methods for collecting and storing whole blood, we emphasize the need for direct separation of the cellular and liquid components of blood to produce cell-free plasma to expand clinical utility. Integrating advanced functionality while maintaining simple user operation presents a viable means of revolutionizing self-administered microsampling, establishing new avenues for innovation in materials science, and expanding access to healthcare.
Collapse
Affiliation(s)
- Keith R. Baillargeon
- Department of Chemistry, Laboratory for Living DevicesTufts UniversityMedfordMassachusettsUSA
| | - Charles R. Mace
- Department of Chemistry, Laboratory for Living DevicesTufts UniversityMedfordMassachusettsUSA
| |
Collapse
|
3
|
Development and Implementation of Dried Blood Spot-Based COVID-19 Serological Assays for Epidemiologic Studies. Microbiol Spectr 2022; 10:e0247121. [PMID: 35612315 PMCID: PMC9241704 DOI: 10.1128/spectrum.02471-21] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Serological surveillance studies of infectious diseases provide population-level estimates of infection and antibody prevalence, generating crucial insight into population-level immunity, risk factors leading to infection, and effectiveness of public health measures. These studies traditionally rely on detection of pathogen-specific antibodies in samples derived from venipuncture, an expensive and logistically challenging aspect of serological surveillance. During the COVID-19 pandemic, guidelines implemented to prevent the spread of SARS-CoV-2 infection made collection of venous blood logistically difficult at a time when SARS-CoV-2 serosurveillance was urgently needed. Dried blood spots (DBS) have generated interest as an alternative to venous blood for SARS-CoV-2 serological applications due to their stability, low cost, and ease of collection; DBS samples can be self-generated via fingerprick by community members and mailed at ambient temperatures. Here, we detail the development of four DBS-based SARS-CoV-2 serological methods and demonstrate their implementation in a large serological survey of community members from 12 cities in the East Bay region of the San Francisco metropolitan area using at-home DBS collection. We find that DBS perform similarly to plasma/serum in enzyme-linked immunosorbent assays and commercial SARS-CoV-2 serological assays. In addition, we show that DBS samples can reliably detect antibody responses months postinfection and track antibody kinetics after vaccination. Implementation of DBS enabled collection of valuable serological data from our study population to investigate changes in seroprevalence over an 8-month period. Our work makes a strong argument for the implementation of DBS in serological studies, not just for SARS-CoV-2, but any situation where phlebotomy is inaccessible. IMPORTANCE Estimation of community-level antibody responses to SARS-CoV-2 from infection or vaccination is critical to inform public health responses. Traditional studies of antibodies rely on collection of blood via venipuncture, an invasive procedure not amenable to pandemic-related social-distancing measures. Dried blood spots (DBS) are an alternative to venipuncture, since they can be self-collected by study participants at home and do not require refrigeration for shipment or storage. However, DBS-based assays to measure antibody levels to SARS-CoV-2 have not been widely utilized. Here, we show that DBS are comparable to blood as a sampling method for antibody responses to SARS-CoV-2 infection and vaccination over time measured using four distinct serological assays. The DBS format enabled antibody surveillance in a longitudinal cohort where study participants self-collected samples, ensuring the participants’ safety during an ongoing pandemic. Our work demonstrates that DBS are an excellent sampling method for measuring antibody responses whenever venipuncture is impractical.
Collapse
|
4
|
Athanasiou LV, Katsogiannou EG, Tsokana CN, Dedousi A, Boutsini S, Papakonstantinou G, Papatsiros VG. Detection of Antibodies Against Toxoplasma gondii in Filter Paper-Dried Blood Dot Spots Compared with Serum in Pigs and Assessment of Variation Associated with Packed Cell Volume. Foodborne Pathog Dis 2022; 19:394-399. [PMID: 35443790 DOI: 10.1089/fpd.2021.0115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The aim of this study was to assess the agreement between anti-Toxoplasma gondii IgG antibody detection in serum and filter paper (FP) blood spots using the indirect immunofluorescence antibody assay (IFA) and to evaluate the potential impact of the packed cell volume (PCV) on antibody detection in FPs. A pair of a serum and an FP sample was collected from 96 sows at various farms in Greece, with previously identified high seropositivity and/or risk factors associated with high seropositivity against T. gondii. The PCV value was determined using the microhematocrit method. IFA was used for the detection of antibodies against T. gondii. T. gondii-specific antibodies were detected in 45.8% serum samples and 41.6% FP samples showing almost perfect agreement. Detection in FP samples presented high sensitivity (87.1-92.8%) and excellent specificity (100%) when compared with detection in serum, regardless of the PCV values. The findings of this study support the reliability of FPs for the evaluation of the serological status of swine against T. gondii. FPs could be a good alternative sample type compared with serum for large-scale epidemiological studies.
Collapse
Affiliation(s)
- Labrini V Athanasiou
- Clinic of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece
| | - Eleni G Katsogiannou
- Clinic of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece
| | - Constantina N Tsokana
- Clinic of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece
| | - Anna Dedousi
- Veterinary Research Institute, HAO-Demeter, Thessaloniki, Greece
| | - Sofia Boutsini
- Parasitology - Parasitic Diseases, Entomology, and Bee Health Department, Veterinary Center of Athens/General Directorate of Veterinary Services, Athens, Greece
| | - George Papakonstantinou
- Clinic of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece
| | - Vasileios G Papatsiros
- Clinic of Medicine, Faculty of Veterinary Medicine, University of Thessaly, Karditsa, Greece
| |
Collapse
|
5
|
Wood J, Minter LJ, Bibus D, Tollefson TN, Ange-van Heugten K. Assessment of the effects of storage temperature on fatty acid analysis using dried blood spot cards from managed southern white rhinoceroses ( Ceratotherium simum simum): implications for field collection and nutritional care. PeerJ 2022; 10:e12896. [PMID: 35186484 PMCID: PMC8852271 DOI: 10.7717/peerj.12896] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 01/16/2022] [Indexed: 01/11/2023] Open
Abstract
BACKGROUND Southern white rhinoceroses (Ceratotherium simum simum) are an endangered species in decline due to poaching and negative habitat changes. Conservation of the species has become increasingly important and a focus on better human management has become prevalent. One area of management that impacts southern white rhinoceroses is nutritional health monitoring, which is often conducted through blood analysis. Blood analysis conducted during field research can be difficult due to temperature, distance, and limited technological resources, so new methods of fast, and relatively stable blood collection are being pursued. One method that has been used in humans for many years is beginning to make its way into wildlife studies: the use of dried blood spot (DBS) cards. These cards are used as a tool to store single drops of whole blood on specialized filter paper and, once dried, can be used for nutritional biomarker analysis. An area of interest for southern white rhinoceroses and nutrition is monitoring fatty acid percentages for cardiovascular, immune, and reproductive health. The time and temperature limitations for storing blood fractions or liquid whole blood when analyzing fatty acids have been investigated, but few studies have performed storage studies on DBS cards colder than -20 °C or in non-human species. METHODS In order to better understand the limitations of DBS cards and the impact of temperature on fatty acid DBS samples in long-term storage, triplicate samples from seven adult southern white rhinoceroses at the North Carolina Zoo were collected and subjected to three storage treatments (immediate, room temperature (23 °C), or frozen (-80 °C) for 1 year). RESULTS Stearidonic (18:4w3) (Δ 0.3%), arachdic (20:0) (Δ 0.1%), eicosatetraenoic (20:4w3) (Δ 0.2%), and erucic acid (22:1w9) (Δ 0.1%) were in higher concentration in frozen than initial. Fatty acids in higher concentrations in the initial samples than frozen were myristic (14:0) (Δ 0.2%), mead (20:3w9) (Δ 0.1%), docosatetraenoic (22:4w6) (Δ 0.2%), nervonic (24:1) (Δ 0.1%), and total highly unsaturated fatty acids (HUFAs) (Δ 0.7%). Stearic (18:0) (Δ 2.2%), stearidonic (18:4w3) (Δ 0.3%), arachdic (20:0) (Δ 0.2%), paullinic (20:1w7) (Δ 0.4%), eicosatetraenoic (20:4w3) (Δ 0.1%), eicosapentaenoic (20:5w3) (Δ 0.1%), docosatetraenoic (22:4w6) (Δ 0.2%), nervonic acid (24:1) (Δ 0.2%), monoenes (Δ 1.9%), and total saturates (Δ 3.6%) had higher concentrations in room temperature than initial. Linoleic (18:2w6) (Δ 4.9%), mead acid (20:3w9) (Δ 0.1%), total polyunsaturated fatty acids (5.3%), and total omega-6 fatty acids (Δ 4.8%) had higher concentrations in initial compared to room temperature. Arachidonic (20:4w6) (Δ 0.4%) and omega-3 docosapentaenoic acid (22:5w3) (Δ 0.1%), had higher concentrations in frozen than in room temperature. DISCUSSION The frozen samples had the fewest statistical differences compared to room temperature samples and essential omega-3 and -6 fatty acids were stable with freezing up to 1 year. While more research is still warranted, current results suggest that DBS samples are best utilized when immediate analysis or -80 °C storage is available.
Collapse
Affiliation(s)
- Jordan Wood
- Animal Science, North Carolina State University, Raleigh, North Carolina, United States
| | | | - Doug Bibus
- Lipid Technologies LLC, Austin, Minnesota, United States
| | - Troy N. Tollefson
- Mazuri® Exotic Animal Nutrition, PMI Nutrition, Land O’ Lakes, Inc., St. Louis, Missouri, United States
| | | |
Collapse
|
6
|
Development and Validation of a Multiplex Microsphere Immunoassay Using Dried Blood Spots for SARS-CoV-2 Seroprevalence: Application in First Responders in Colorado, USA. J Clin Microbiol 2021; 59:JCM.00290-21. [PMID: 33795412 PMCID: PMC8315929 DOI: 10.1128/jcm.00290-21] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 03/26/2021] [Indexed: 01/19/2023] Open
Abstract
Serological testing of large representative populations for antibodies to SARS-CoV-2 is needed to estimate seroprevalence, transmission dynamics, and the duration of antibody responses from natural infection and vaccination. In this study, a high-throughput SARS-CoV-2 multiplex microsphere immunoassay (MMIA) was developed for the receptor binding domain (RBD) and nucleocapsid (N) that was more sensitive than enzyme-linked immunosorbent assay (ELISA) (98% versus 87%). The MMIA was then applied and validated in 264 first responders in Colorado using serum and dried blood spot (DBS) eluates, compared to ELISA, and evaluated for neutralizing antibodies. Four percent (11/264) of first responders were seropositive in July to August 2020. Serum and DBS were highly correlated for anti-RBD and anti-N antibodies (R = 0.83, P < 0.0001 and R = 0.87, P < 0.0001, respectively) by MMIA. The MMIA accurately predicted SARS-CoV-2 neutralizing antibodies using DBS (R = 0.76, P = 0.037). On repeat antibody testing 3 months later, anti-RBD IgG decreased less rapidly than anti-N IgG measured by MMIA, with a median change in geometric median fluorescence intensity of 62% versus 79% (P < 0.01) for anti-RBD and anti-N IgG, respectively. This novel MMIA using DBS could be scalable for rapid and affordable SARS-CoV-2 serosurveillance in the United States and globally.
Collapse
|
7
|
Page M, Atabani S, Arumainayagam J, Wilson S, Hartland D, Taylor S. Are all blood-based postal sampling kits the same? A comparative service evaluation of the performance of dried blood spot and mini tube sample collection systems for postal HIV and syphilis testing. Sex Transm Infect 2021; 97:209-214. [PMID: 33214322 PMCID: PMC7677894 DOI: 10.1136/sextrans-2020-054692] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 10/01/2020] [Accepted: 10/18/2020] [Indexed: 12/02/2022] Open
Abstract
OBJECTIVES We comparatively evaluated two HIV and syphilis blood sampling kits (dried blood spot (DBS) and mini tube (MT)) as part of an online STI postal sampling service that included tests for chlamydia and gonorrhoea. We aimed to see how the blood collection systems compared regarding sample return rates and result rates. Additionally, we aimed to observe differences in false-positive results and describe a request-to-result ratio (RRR)-the required number of kit requests needed to obtain one successful result. METHODS We reviewed data from an online postal STI kit requesting service for a client transitioning from MT to DBS blood collection systems. We described service user baseline characteristics and compared kit requests, kit and blood sample return rates, and the successful resulting rates for HIV and syphilis for MT and DBS. Pearson's χ2 and Fisher's exact test were used to determine statistical differences, and statistical formulae were applied to produce CIs for differences in proportions. RESULTS 5670 STI postal kit requests from a Midlands region were reviewed from 6 September 2016-2 January 2019 (1515 MT and 4155 DBS). Baseline characteristics between the two groups were comparable (68.0% female, 74.0% white British and 87.5% heterosexual, median age 26 years). Successful processing rates for DBS were 94.6% and 54.4% for MT (p<0.001) with a percentage difference of 40.2% (95% CI 36.9% to 43.4%). The RRR for MT was 2.9 cf. 1.6 for DBS. False-positive results for MT samples were 5.2% (HIV) and 0.4% (syphilis), and those for DBS were 0.4% (HIV) and 0.0% (syphilis). CONCLUSIONS This comparative analysis demonstrated the superior successful processing rates for postal DBS collection systems compared with MT. Reasons for this included insufficient volumes, high false-positive rates and degradation of blood quality in MT samples. A postal sampling service using DBS to screen for HIV, syphilis and other blood-borne viruses could be a viable alternative.
Collapse
Affiliation(s)
- Matthew Page
- Directorate of Infection and Immunology, University Hospitals Birmingham, NHS Foundation Trust, Birmingham, West Midlands, UK
- Institute of Applied Health Research, University of Birmingham, Birmingham, West Midlands, UK
| | - Sowsan Atabani
- Public Health Laboratory Birmingham, Public Health England Midlands and East Region, Birmingham, Birmingham, UK
| | - Joseph Arumainayagam
- Walsall Integrated Contraception and Sexual Health Services, Walsall Healthcare NHS Trust, Walsall, Walsall, UK
| | - Steven Wilson
- Public Health Laboratory Birmingham, Public Health England Midlands and East Region, Birmingham, Birmingham, UK
| | - Daniel Hartland
- The Saving Lives Charity, Lifford Hall, Lifford Lane, Birmingham, West Midlands, UK
| | - Stephen Taylor
- Directorate of Infection and Immunology, University Hospitals Birmingham, NHS Foundation Trust, Birmingham, West Midlands, UK
- Institute of Applied Health Research, University of Birmingham, Birmingham, West Midlands, UK
| |
Collapse
|
8
|
Mulchandani R, Brown B, Brooks T, Semper A, Machin N, Linley E, Borrow R, Wyllie D. Use of dried blood spot samples for SARS-CoV-2 antibody detection using the Roche Elecsys ® high throughput immunoassay. J Clin Virol 2021; 136:104739. [PMID: 33588354 PMCID: PMC7817498 DOI: 10.1016/j.jcv.2021.104739] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 12/24/2020] [Accepted: 01/14/2021] [Indexed: 02/06/2023]
Abstract
Dried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing Hepatitis C and by Public Health England for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches for SARS-CoV-2 antibody detection is uncertain. The study aimed to compare antibody detection in DBS eluates using the Roche Elecsys ® immunoassay with antibody detection in paired plasma samples, using the same assay. The study was in one Police and one Fire & Rescue facility in England; it comprised of 195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome measures were sensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. 18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using an experimental cut-off, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. DBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.
Collapse
Affiliation(s)
- Ranya Mulchandani
- Field Service, Public Health England, United Kingdom; UK Field Epidemiology Training Programme, Public Health England, United Kingdom.
| | - Ben Brown
- Public Health Laboratory Manchester, Public Health England, United Kingdom
| | - Tim Brooks
- Porton Down, Public Health England, United Kingdom
| | | | - Nicholas Machin
- Public Health Laboratory Manchester, Public Health England, United Kingdom
| | - Ezra Linley
- Public Health Laboratory Manchester, Public Health England, United Kingdom
| | - Ray Borrow
- Public Health Laboratory Manchester, Public Health England, United Kingdom
| | - David Wyllie
- Field Service, Public Health England, United Kingdom
| |
Collapse
|
9
|
Boyce RM, Collins M, Muhindo R, Nakakande R, Ciccone EJ, Grounds S, Espinoza D, Zhu Y, Matte M, Ntaro M, Nyehangane D, Juliano JJ, Mulogo EM. Dengue in Western Uganda: a prospective cohort of children presenting with undifferentiated febrile illness. BMC Infect Dis 2020; 20:835. [PMID: 33176708 PMCID: PMC7661220 DOI: 10.1186/s12879-020-05568-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 10/30/2020] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND The spatial distribution and burden of dengue in sub-Saharan Africa remains highly uncertain, despite high levels of ecological suitability. The goal of this study was to describe the epidemiology of dengue among a cohort of febrile children presenting to outpatient facilities located in areas of western Uganda with differing levels of urbanicity and malaria transmission intensity. METHODS Eligible children were first screened for malaria using rapid diagnostic tests. Children with a negative malaria result were tested for dengue using a combination NS1/IgM/IgG rapid test (SD Bioline Dengue Duo). Confirmatory testing by RT-PCR was performed in a subset of participants. Antigen-capture ELISA was performed to estimate seroprevalence. RESULTS Only 6 of 1416 (0.42%) children had a positive dengue rapid test, while none of the RT-PCR results were positive. ELISA testing demonstrated reactive IgG antibodies in 28 (2.2%) participants with the highest prevalence seen at the urban site in Mbarara (19 of 392, 4.9%, p < 0.001). CONCLUSIONS Overall, these findings suggest that dengue, while present, is an uncommon cause of non-malarial, pediatric febrile illness in western Uganda. Further investigation into the eocological factors that sustain low-level transmission in urban settings are urgently needed to reduce the risk of epidemics.
Collapse
Affiliation(s)
- Ross M Boyce
- Division of Infectious Diseases, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, 27599, USA. .,Department of Community Health, Faculty of Medicine, Mbarara University of Science & Technology, Mbarara, Uganda.
| | - Matthew Collins
- Division of Infectious Diseases, Emory University, Atlanta, GA, 30322, USA
| | - Rabbison Muhindo
- Department of Community Health, Faculty of Medicine, Mbarara University of Science & Technology, Mbarara, Uganda
| | - Regina Nakakande
- Department of Community Health, Faculty of Medicine, Mbarara University of Science & Technology, Mbarara, Uganda
| | - Emily J Ciccone
- Division of Infectious Diseases, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, 27599, USA
| | - Samantha Grounds
- Division of Infectious Diseases, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, 27599, USA.,College of Arts and Sciences, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, 27599, USA
| | - Daniel Espinoza
- Division of Infectious Diseases, Emory University, Atlanta, GA, 30322, USA
| | - Yerun Zhu
- Division of Infectious Diseases, Emory University, Atlanta, GA, 30322, USA
| | - Michael Matte
- Department of Community Health, Faculty of Medicine, Mbarara University of Science & Technology, Mbarara, Uganda
| | - Moses Ntaro
- Department of Community Health, Faculty of Medicine, Mbarara University of Science & Technology, Mbarara, Uganda
| | - Dan Nyehangane
- Department of Community Health, Faculty of Medicine, Mbarara University of Science & Technology, Mbarara, Uganda.,Epicentre Mbarara Research Centre, Mbarara, Uganda
| | - Jonathan J Juliano
- Division of Infectious Diseases, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, 27599, USA
| | - Edgar M Mulogo
- Department of Community Health, Faculty of Medicine, Mbarara University of Science & Technology, Mbarara, Uganda
| |
Collapse
|
10
|
Morley GL, Taylor S, Jossi S, Perez-Toledo M, Faustini SE, Marcial-Juarez E, Shields AM, Goodall M, Allen JD, Watanabe Y, Newby ML, Crispin M, Drayson MT, Cunningham AF, Richter AG, O’Shea MK. Sensitive Detection of SARS-CoV-2-Specific Antibodies in Dried Blood Spot Samples. Emerg Infect Dis 2020; 26:2970-2973. [PMID: 32969788 PMCID: PMC7706975 DOI: 10.3201/eid2612.203309] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Dried blood spot (DBS) samples can be used for the detection of severe acute respiratory syndrome coronavirus 2 spike antibodies. DBS sampling is comparable to matched serum samples with a relative 98.1% sensitivity and 100% specificity. Thus, DBS sampling offers an alternative for population-wide serologic testing in the coronavirus pandemic.
Collapse
|
11
|
Dried Blood Spot in Laboratory: Directions and Prospects. Diagnostics (Basel) 2020; 10:diagnostics10040248. [PMID: 32340321 PMCID: PMC7235996 DOI: 10.3390/diagnostics10040248] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 04/16/2020] [Accepted: 04/21/2020] [Indexed: 12/14/2022] Open
Abstract
Over the past few years, dried blood spot (DBS) technology has become a convenient tool in both qualitative and quantitative biological analysis. DBS technology consists of a membrane carrier (MC) on the surface of which a biomaterial sample becomes absorbed. Modern analytical, immunological or genomic methods can be employed for analysis after drying the sample. DBS has been described as the most appropriate method for biomaterial sampling due to specific associated inherent advantages, including the small volumes of biomaterials required, the absence of a need for special conditions for samples’ storage and transportation, improved stability of analytes and reduced risk of infection resulting from contaminated samples. This review illustrates information on the current state of DBS technology, which can be useful and helpful for biomedical researchers. The prospects of using this technology to assess the metabolomic profile, assessment, diagnosis of communicable diseases are demonstrated.
Collapse
|
12
|
Abstract
This paper focuses on one of the most commonly encountered materials in our society, namely paper. Paper is an inherently complex material, yet its use provides for chemical analysis approaches that are elegant in their simplicity of execution. In the first half of the previous century, paper in scientific research was used mainly for filtration and chromatographic separation. While its use decreased with the rise of modern elution chromatography, paper remains a versatile substrate for low-cost analytical tests. Recently, we have seen renewed interest to work with paper in (bio)analytical science, a result of the growing demand for inexpensive, portable analysis. Dried blood spotting, paper microfluidics, and paper spray ionization are areas in which paper is (re)establishing itself as an important material. These research areas all exploit several properties of paper, including stable sample storage, passive fluid movement and manipulation, chromatographic separation/extraction, modifiable surface and/or volume, easily altered shape, easy transport, and low cost. We propose that the real, and to date underexploited, potential of paper lies in utilizing its combined characteristics to add new dimensions to paper-based (bio)chemical analysis, expanding its applicability. This article provides the reader with a short historical perspective on the scientific use of paper and the developments that led to the establishment of the aforementioned research areas. We review important characteristics of paper and place them in a scientific context in this descriptive, yet critical, assessment of the achieved and the achievable in paper-based analysis. The ultimate goal is the exploration of integrative approaches at the interface between the different fields in which paper is or can be used.
Collapse
Affiliation(s)
- G Ij Salentijn
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy , University of Groningen , Antonius Deusinglaan 1 , 9713 AV Groningen , The Netherlands.,Laboratory of Organic Chemistry , Wageningen University and Research , Stippeneng 4 , 6708 WE Wageningen , The Netherlands
| | - M Grajewski
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy , University of Groningen , Antonius Deusinglaan 1 , 9713 AV Groningen , The Netherlands
| | - E Verpoorte
- Pharmaceutical Analysis, Groningen Research Institute of Pharmacy , University of Groningen , Antonius Deusinglaan 1 , 9713 AV Groningen , The Netherlands
| |
Collapse
|
13
|
Page M, Atabani SF, Wood M, Smit E, Wilson S, Atherton C, Davenport CF, Hartland D, Simpson M, Taylor S. Dried blood spot and mini-tube blood sample collection kits for postal HIV testing services: a comparative review of successes in a real-world setting. Sex Transm Infect 2018; 95:43-45. [PMID: 30072393 DOI: 10.1136/sextrans-2018-053567] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 04/30/2018] [Accepted: 05/20/2018] [Indexed: 11/03/2022] Open
Abstract
OBJECTIVES This is a comparative review between using dried blood spot (DBS) and mini-tube (MT) HIV sampling kits as part of an online sexually transmitted infection (STI) postal testing service. England has recently seen increases in internet-based and postal (eHealth) STI services. Expanding accessibility and testing for patients, cost implications and narrowing the HIV undiagnosed margin are drivers for this. METHODS In 2017, data were reviewed from an online postal STI kit requesting service at a time of transitioning from MT to DBS. We compared the STI postal kit and HIV blood sample return rates, and the successful processing/analysis rates of the DBS and MT kits. Descriptive statistics were applied to participant characteristics, with Pearson's χ2 or Fisher exact test used to demonstrate statistical differences. We also describe and calculate a 'request-to-result ratio' (RRR) for both kit types. The RRR is defined as the number of online kit requests required to produce one successfully analysed result. RESULTS 550 STI postal kit requests from a North-West of England region were reviewed from 13 June 2017 to 22 September 2017 (275 MT, 275 DBS). Baseline characteristics between the two groups were comparable (63% woman, 90% white British and 86% heterosexual with a median age of 26 years). The successful processing rate for the DBS was 98.8% c.f. 55.7% for the MT (p<0.001). The RRR for MT was 2.96, c.f. 1.70 for DBS. There was a 5.4% false positive HIV rate in the MT c.f. none in the DBS. CONCLUSIONS This comparative analysis suggests that in this community setting, the use of postal HIV DBS kits resulted in a significantly improved RRR compared with MT. The biggest factor was the large number of MT samples not analysed due to inadequate blood volumes. The unexpected level of false positive results in the MT samples needs confirming in larger studies.
Collapse
Affiliation(s)
- Matthew Page
- Birmingham Heartlands HIV Service, Heartlands Hospital, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.,Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | - Sowsan F Atabani
- Public Health England Birmingham Laboratories, Heartlands Hospital, Birmingham, UK
| | - Martyn Wood
- Sexual Health Wirral, Wirral Community NHS Foundation Trust, Birkenhead, UK
| | - Erasmus Smit
- Public Health England Birmingham Laboratories, Heartlands Hospital, Birmingham, UK
| | - Steven Wilson
- Public Health England Birmingham Laboratories, Heartlands Hospital, Birmingham, UK
| | - Carol Atherton
- Public Health England Birmingham Laboratories, Heartlands Hospital, Birmingham, UK
| | - Clare F Davenport
- Institute of Applied Health Research, University of Birmingham, Birmingham, UK
| | | | | | - Stephen Taylor
- Birmingham Heartlands HIV Service, Heartlands Hospital, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.,The Saving Lives Charity, Birmingham, UK.,Institute of Microbiology and Infection, University of Birmingham, Birmingham, UK
| |
Collapse
|
14
|
Henderson CA, McLiesh H, Then WL, Garnier G. Activity and Longevity of Antibody in Paper-Based Blood Typing Diagnostics. Front Chem 2018; 6:193. [PMID: 29900168 PMCID: PMC5988841 DOI: 10.3389/fchem.2018.00193] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 05/14/2018] [Indexed: 11/13/2022] Open
Abstract
Paper-based diagnostics provide a low-cost, reliable and easy to use mode of blood typing. The shelf-life of such products, however, can be limited due to the reduced activity of reagent antibodies sorbed on the paper cellulose fibers. This study explores the effects of aging on antibody activity for periods up to 12 months on paper and in solution under different aging and drying conditions-air-dried, lyophilized, and kept as a liquid. Paper kept wet with undiluted antibody is shown to have the longest shelf-life and the clearest negatives. Antibody diluted with bovine serum albumin (BSA) protects against the lyophilization process, however, beyond 9 months aging, false positives are seen. Paper with air-dried antibodies is not suitable for use after 1 month aging. These results inform preparation and storage conditions for the development of long shelf-life blood grouping paper-based diagnostics.
Collapse
Affiliation(s)
- Clare A Henderson
- Department of Chemical Engineering, Bioresource Processing Research Institute of Australia, Monash University, Clayton, VIC, Australia
| | - Heather McLiesh
- Department of Chemical Engineering, Bioresource Processing Research Institute of Australia, Monash University, Clayton, VIC, Australia
| | - Whui L Then
- Department of Chemical Engineering, Bioresource Processing Research Institute of Australia, Monash University, Clayton, VIC, Australia.,Haemokinesis Pty Ltd., Hallam, VIC, Australia
| | - Gil Garnier
- Department of Chemical Engineering, Bioresource Processing Research Institute of Australia, Monash University, Clayton, VIC, Australia
| |
Collapse
|
15
|
Formenti F, Buonfrate D, Prandi R, Marquez M, Caicedo C, Rizzi E, Guevara AG, Vicuña Y, Huerlo FR, Perandin F, Bisoffi Z, Anselmi M. Comparison of S. stercoralis Serology Performed on Dried Blood Spots and on Conventional Serum Samples. Front Microbiol 2016; 7:1778. [PMID: 27877170 PMCID: PMC5099234 DOI: 10.3389/fmicb.2016.01778] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 10/24/2016] [Indexed: 11/17/2022] Open
Abstract
Background: Dried blood spots (DBS) are used for epidemiological surveys on infectious diseases in settings where limited resources are available. In fact, DBS can help to overcome logistic difficulties for the collection, transport and storage of biological specimens. Objective: To evaluate the accuracy of Strongyloides stercoralis serology performed on DBS. Methods: A survey was proposed to children attending a school in the village of Borbon, Ecuador, and to their parents/guardians. Each participant gave consent to the collection of both serum and DBS specimens. DBS absorbed on filter papers were analyzed with a commercially available ELISA test for S. stercoralis antibodies, as well as with standard serology. The agreement between the two methods was assessed through the Cohen’s kappa coefficient. Results: The study sample was composed of 174 children and 61 adults, for a total of 235 serum and 235 DBS samples. The serology was positive in 31/235 (13%) serum samples, and in 27/235 (11%) DBS: 4 samples resulted discordant (positive at standard serology). Cohen’s kappa coefficient was 0.921 (95% CI 0.845 – 0.998), indicating a high rate of concordance. Conclusion: DBS are suitable for in field-surveys requiring serological testing for S. stercoralis.
Collapse
Affiliation(s)
- Fabio Formenti
- Centre for Tropical Diseases, Sacro Cuore Hospital Verona, Italy
| | - Dora Buonfrate
- Centre for Tropical Diseases, Sacro Cuore Hospital Verona, Italy
| | - Rosanna Prandi
- Centro de Epidemiología Comunitaria y Medicina Tropical Esmeraldas, Ecuador
| | - Monica Marquez
- Centro de Epidemiología Comunitaria y Medicina Tropical Esmeraldas, Ecuador
| | - Cintia Caicedo
- Centro de Epidemiología Comunitaria y Medicina Tropical Esmeraldas, Ecuador
| | - Eleonora Rizzi
- Centre for Tropical Diseases, Sacro Cuore Hospital Verona, Italy
| | - Angel G Guevara
- Instituto de Biomedicina, Carrera de Medicina, Universidad Central del Ecuador Quito, Ecuador
| | - Yosselin Vicuña
- Instituto de Biomedicina, Carrera de Medicina, Universidad Central del Ecuador Quito, Ecuador
| | | | | | - Zeno Bisoffi
- Centre for Tropical Diseases, Sacro Cuore Hospital Verona, Italy
| | - Mariella Anselmi
- Centre for Tropical Diseases, Sacro Cuore HospitalVerona, Italy; Centro de Epidemiología Comunitaria y Medicina TropicalEsmeraldas, Ecuador
| |
Collapse
|
16
|
Ulum MF, Maylina L, Noviana D, Wicaksono DHB. EDTA-treated cotton-thread microfluidic device used for one-step whole blood plasma separation and assay. LAB ON A CHIP 2016; 16:1492-1504. [PMID: 27021631 DOI: 10.1039/c6lc00175k] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This study aims to observe the wicking and separation characteristics of blood plasma in a cotton thread matrix functioning as a microfluidic thread-based analytical device (μTAD). We investigated several cotton thread treatment methods using ethylenediaminetetraacetic acid (EDTA) anticoagulant solution for wicking whole blood samples and separating its plasma. The blood of healthy Indonesian thin tailed sheep was used in this study to understand the properties of horizontal wicking and separation on the EDTA-treated μTAD. The wicking distance and blood cell separation from its plasma was observed for 120 s and documented using a digital phone camera. The results show that untreated cotton-threads stopped the blood wicking process on the μTAD. On the other hand, the deposition of EDTA anticoagulant followed by its drying on the thread at room temperature for 10 s provides the longest blood wicking with gradual blood plasma separation. Furthermore, the best results in terms of the longest wicking and the clearest on-thread separation boundary between blood cells and its plasma were obtained using the μTAD treated with EDTA deposition followed by 60 min drying at refrigerated temperature (2-8 °C). The separation length of blood plasma in the μTADs treated with dried-EDTA at both room and refrigerated temperatures was not statistically different (P > 0.05). This separation occurs through the synergy of three factors, cotton fiber, EDTA anticoagulant and blood platelets, which induce the formation of a fibrin-filter via a partial coagulation process in the EDTA-treated μTAD. An albumin assay was employed to demonstrate the efficiency of this plasma separation method during a one-step assay on the μTAD. Albumin in blood is an important biomarker for kidney and heart disease. The μTAD has a slightly better limit of detection (LOD) than conventional blood analysis, with an LOD of 114 mg L(-1) compared to 133 mg L(-1), respectively. However, the μTAD performed faster to get results after 3 min compared to 14 min for centrifuged analysis of sheep blood samples. In conclusion, on-thread dried-EDTA anticoagulant deposition was able to increase the wicking distance and has a better capability to separate blood plasma and is suitable for combining separation and the assay system in a single device.
Collapse
Affiliation(s)
- Mokhamad Fakhrul Ulum
- Medical Devices and Technology Group (MediTeg), Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia (UTM), Skudai 81310, Johor, Malaysia. and Faculty of Veterinary Medicine, Bogor Agricultural University (IPB), Bogor, Indonesia.
| | - Leni Maylina
- Faculty of Veterinary Medicine, Bogor Agricultural University (IPB), Bogor, Indonesia.
| | - Deni Noviana
- Faculty of Veterinary Medicine, Bogor Agricultural University (IPB), Bogor, Indonesia.
| | - Dedy Hermawan Bagus Wicaksono
- Medical Devices and Technology Group (MediTeg), Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia (UTM), Skudai 81310, Johor, Malaysia. and IJN-UTM Cardiovascular Engineering Centre (CEC), Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia (UTM), Skudai 81310, Johor, Malaysia
| |
Collapse
|
17
|
McAllister G, Shepherd S, Templeton K, Aitken C, Gunson R. Long term stability of HBsAg, anti-HBc and anti-HCV in dried blood spot samples and eluates. J Clin Virol 2015; 71:10-7. [PMID: 26370308 DOI: 10.1016/j.jcv.2015.07.303] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 07/23/2015] [Accepted: 07/25/2015] [Indexed: 11/15/2022]
Abstract
BACKGROUND Dried blood spots (DBS) are a useful specimen collection tool in situations where venous access is problematic, however, detection of biomarkers from this specimen type is subject to variation depending on storage conditions and storage time. OBJECTIVES The objective of this study is to assess the detection of HBsAg, anti-HBc and anti-HCV from DBS after storage. STUDY DESIGN DBS specimens were stored at -70°C, -20°C, 4°C, 22 to 28°C and 37°C either with or without desiccant. Eluates were also prepared from DBS specimens and stored at -20°C and -70°C. DBS cards and eluates were tested for HBsAg, anti-HBc and anti-HCV at baseline on day 0 and thereafter at intervals of 14, 70 and 200 days. RESULTS Loss of detection of both HBsAg and anti-HBc was evident by the first time point (14 days) in all storage conditions except for the samples (DBS and eluates) stored at -20°C or -70°C. Both HBsAg and anti-HBc stored under these conditions showed minimal variation up to the final time point (200 days) of storage. The detection of anti-HCV did not differ between the 22 to 28°C, 4°C, -20°C and -70°C DBS nor the -20°C or the -70°C stored eluates over the 200 day time period. CONCLUSION We suggest that extended storage of DBS intended for downstream testing is best carried out by freezing either the DBS, or eluate, at -20°C or -70°C as soon as possible following collection for optimal detection of HBsAg, anti-HBc and anti-HCV.
Collapse
Affiliation(s)
- Georgina McAllister
- East of Scotland Specialist Virology Centre, Edinburgh Royal Infirmary, 51 Little France Crescent, Edinburgh, Scotland, UK.
| | - Samantha Shepherd
- West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, Scotland, UK
| | - Kate Templeton
- East of Scotland Specialist Virology Centre, Edinburgh Royal Infirmary, 51 Little France Crescent, Edinburgh, Scotland, UK
| | - Celia Aitken
- West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, Scotland, UK
| | - Rory Gunson
- West of Scotland Specialist Virology Centre, Glasgow Royal Infirmary, Glasgow, Scotland, UK
| |
Collapse
|
18
|
Randriamparany T, Kouakou KV, Michaud V, Fernández-Pinero J, Gallardo C, Le Potier MF, Rabenarivahiny R, Couacy-Hymann E, Raherimandimby M, Albina E. African Swine Fever Diagnosis Adapted to Tropical Conditions by the Use of Dried-blood Filter Papers. Transbound Emerg Dis 2014; 63:379-88. [PMID: 25430732 DOI: 10.1111/tbed.12295] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2014] [Indexed: 11/26/2022]
Abstract
The performance of Whatman 3-MM filter papers for the collection, drying, shipment and long-term storage of blood at ambient temperature, and for the detection of African swine fever virus and antibodies was assessed. Conventional and real-time PCR, viral isolation and antibody detection by ELISA were performed on paired samples (blood/tissue versus dried-blood 3-MM filter papers) collected from experimentally infected pigs and from farm pigs in Madagascar and Côte d'Ivoire. 3-MM filter papers were used directly in the conventional and real-time PCR without previous extraction of nucleic acids. Tests that performed better with 3-MM filter papers were in descending order: virus isolation, real-time UPL PCR and conventional PCR. The analytical sensitivity of real-time UPL PCR on filter papers was similar to conventional testing (virus isolation or conventional PCR) on organs or blood. In addition, blood-dried filter papers were tested in ELISA for antibody detection and the observed sensitivity was very close to conventional detection on serum samples and gave comparable results. Filter papers were stored up to 9 months at 20-25°C and for 2 months at 37°C without significant loss of sensitivity for virus genome detection. All tests on 3-MM filter papers had 100% specificity compared to the gold standards. Whatman 3-MM filter papers have the advantage of being cheap and of preserving virus viability for future virus isolation and characterization. In this study, Whatman 3-MM filter papers proved to be a suitable support for the collection, storage and use of blood in remote areas of tropical countries without the need for a cold chain and thus provide new possibilities for antibody testing and virus isolation.
Collapse
Affiliation(s)
- T Randriamparany
- Laboratoire National de Diagnostic Vétérinaire, Antananarivo, Madagascar
| | - K V Kouakou
- Laboratoire National d'Appui au Développement Agricole, Bingerville, Côte-d'Ivoire
| | - V Michaud
- CIRAD, UMR CMAEE, Montpellier, France.,INRA, UMR1309 CMAEE, Montpellier, France
| | - J Fernández-Pinero
- Centro de Investigacion en Sanidad Animal (CISA-INIA), Valdeolmos, Spain
| | - C Gallardo
- Centro de Investigacion en Sanidad Animal (CISA-INIA), Valdeolmos, Spain
| | - M-F Le Potier
- Anses, Laboratoire de Ploufragan, Unité Virologie Immunologie Porcines, Ploufragan, France
| | - R Rabenarivahiny
- Laboratoire National de Diagnostic Vétérinaire, Antananarivo, Madagascar
| | - E Couacy-Hymann
- LANADA/Laboratoire Central de Pathologie Animale, Bingerville, Côte-d'Ivoire
| | | | - E Albina
- INRA, UMR1309 CMAEE, Montpellier, France.,CIRAD, UMR CMAEE, Petit-Bourg, Guadeloupe, France
| |
Collapse
|
19
|
|
20
|
Blood collected on filter paper for wildlife serology: evaluating storage and temperature challenges of field collections. J Wildl Dis 2014; 50:308-21. [PMID: 24499329 DOI: 10.7589/2012-06-150] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Filter-paper (FP) blood sampling can facilitate wildlife research and expand disease surveillance. Previous work indicated that Nobuto FP samples from caribou and reindeer (Rangifer tarandus subspecies) had comparable sensitivity and specificity to serum samples (≥ 80% for both) in competitive enzyme-linked immunosorbent assays (cELISAs) for Brucella spp., Neospora caninum, and West Nile virus. The same sensitivity and specificity criteria were met in indirect ELISAs for Brucella spp., bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV), with adjusted FP thresholds used for PI-3 and BRSV. Comparable sensitivity and specificity values to serum were also observed for FP in virus neutralization (VN) assays for bovine viral diarrhea virus types I and II; however, reduced sensitivity is a potential limitation of FP samples in protocols that require undiluted serum (i.e., VN and N. caninum cELISA). We evaluated the performance of FP samples from reindeer and caribou in these nine assays after simulating potential challenges of high-latitude field collections: 1) different durations of storage and 2) different processing/storage regimes involving freezing or drying. Sample pairs (serum and FP) were collected from reindeer and caribou populations in 2007-10 and were tested in duplicate. Comparable performance to serum was defined as sensitivity and specificity ≥ 80%. In the storage experiments, FP performance was determined after 2 mo of storage dry at room temperature, and after two longer periods (variable depending on assay; up to 2 yr). After 1 yr, compared to frozen serum stored for the same period, sensitivity was ≥ 88% for all but two assays (68% BHV-1; 75% PI-3), and specificity remained >90%. A limited trial evaluated the effect of freezing FP samples as opposed to drying them for storage. There were no observed detrimental effects of freezing on FP sample performance, but rigorous investigation is warranted.
Collapse
|
21
|
Wu G, Srivastava J, Zaman MH. Stability measurements of antibodies stored on paper. Anal Biochem 2013; 449:147-54. [PMID: 24361717 DOI: 10.1016/j.ab.2013.12.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2013] [Revised: 10/23/2013] [Accepted: 12/09/2013] [Indexed: 10/25/2022]
Abstract
Reagent storage has been a long-standing challenge for diagnostics, especially those designed for low-resource settings and point-of-care applications. In general, the stability of a reagent relies on careful temperature control, often by refrigeration, which is costly and often unavailable in these remote settings. Poor reagent integrity can negatively affect the reproducibility and reliability of an assay. Given the recent interest in paper-based devices designed for quantitative analysis in point-of-care settings, a better understanding of reagent stability on filter paper is critical for proper device use and its longevity. In this article, we present an independent method to examine the stability of reconstituted antibodies that were stored on filter paper using flow cytometry. We validated the method by measuring the activity as measured by the mean fluorescence intensity (MFI) of antibodies stored with known stabilizers. Furthermore, we demonstrated the potential of our method to screen the influence of other paper treatments and storage processes on antibody stability, which may be applicable to the storage of reagents on paper in general.
Collapse
Affiliation(s)
- Grace Wu
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Jaya Srivastava
- Department of Chemistry and Biochemistry, University of Texas at Austin, Austin, TX 78712, USA
| | - Muhammad H Zaman
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.
| |
Collapse
|
22
|
Sullivan TJ, Antonio-Gaddy MS, Richardson-Moore A, Styer LM, Bigelow-Saulsbery D, Parker MM. Expansion of HIV screening to non-clinical venues is aided by the use of dried blood spots for Western blot confirmation. J Clin Virol 2013; 58 Suppl 1:e123-6. [DOI: 10.1016/j.jcv.2013.08.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2013] [Revised: 07/31/2013] [Accepted: 08/03/2013] [Indexed: 10/26/2022]
|
23
|
Investigating the use of protein saver cards for storage and subsequent detection of bovine anti-Brucella abortus smooth lipopolysaccharide antibodies and gamma interferon. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2013; 20:1669-74. [PMID: 23986318 DOI: 10.1128/cvi.00033-13] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Brucella abortus, a smooth strain of the genus Brucella, is the causative agent of bovine brucellosis. To support the ongoing development of diagnostic tests for bovine brucellosis, the use of Protein Saver cards (Whatman) for bovine blood serum and plasma sample collection has been evaluated. These cards offer significant logistical and safety alternatives to transporting and storing liquid samples and may aid in diagnostic programs and validation studies. To evaluate the utility of these cards, 204 bovine blood serum samples from Brucella-infected and noninfected animals were stored on and eluted from the Protein Saver cards. Anti-Brucella smooth lipopolysaccharide (sLPS) antibody titers for the serum eluates were compared to those of the unprocessed original serum samples by indirect enzyme-linked immunosorbent assay (ELISA). The results showed a highly significant correlation between titers from the serum eluates and the unprocessed sera. Therefore, under these circumstances, serum eluates and unprocessed serum samples may be used interchangeably. Blood plasma from 113 mitogen-stimulated whole-blood samples was added to and eluted from the Protein Saver cards. The gamma interferon (IFN-γ) titers in the plasma eluates were compared to those of the unprocessed plasma samples obtained by IFN-γ ELISA. The results showed a significant correlation between the plasma eluates and the unprocessed plasma samples. To derive a signal in the plasma eluate, it was necessary to develop a novel and highly sensitive ELISA for the detection of IFN-γ. The serum samples stored on cards at room temperature over a 10-day period showed little variation in antibody titers. However, the plasma eluates showed a progressive loss of IFN-γ recovery over 10 days when stored at room temperature.
Collapse
|
24
|
LaFauci G, Adayev T, Kascsak R, Kascsak R, Nolin S, Mehta P, Brown WT, Dobkin C. Fragile X Screening by Quantification of FMRP in Dried Blood Spots by a Luminex Immunoassay. J Mol Diagn 2013; 15:508-17. [DOI: 10.1016/j.jmoldx.2013.02.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2012] [Revised: 02/11/2013] [Accepted: 02/20/2013] [Indexed: 02/03/2023] Open
|
25
|
Thi NV, De N, Praet N, Claes L, Gabriël S, Dorny P. Seroprevalence of trichinellosis in domestic animals in northwestern Vietnam. Vet Parasitol 2013; 193:200-5. [DOI: 10.1016/j.vetpar.2012.11.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2012] [Revised: 11/09/2012] [Accepted: 11/23/2012] [Indexed: 10/27/2022]
|
26
|
Smit PW, van der Vlis T, Mabey D, Changalucha J, Mngara J, Clark BD, Andreasen A, Todd J, Urassa M, Zaba B, Peeling RW. The development and validation of dried blood spots for external quality assurance of syphilis serology. BMC Infect Dis 2013; 13:102. [PMID: 23442198 PMCID: PMC3586363 DOI: 10.1186/1471-2334-13-102] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2012] [Accepted: 02/21/2013] [Indexed: 11/12/2022] Open
Abstract
Background Syphilis causes up to 1,500,000 congenital syphilis cases annually. These could be prevented if all pregnant women were screened, and those with syphilis treated with a single dose of penicillin before 28 weeks gestation. In recent years, rapid point-of-care tests have allowed greater access to syphilis screening, especially in rural or remote areas, but the lack of quality assurance of rapid testing has been a concern. We determined the feasibility of using dried blood spots (DBS) as specimens for quality assurance of syphilis serological assays. Methods We developed DBS extraction protocols for use with Treponema pallidum particle agglutination assay (TPPA), Treponema pallidum haemagglutination assay (TPHA) and an enzyme immunoassay (EIA) and compared the results with those using matching plasma samples from the same patient. Results Since DBS samples showed poor performance with TPHA and EIA (TPHA sensitivity was 50.5% (95% confidence interval: 39.9–61.2%) and EIA specificity was 50.4% (95% CI: 43.7–57.1%), only the DBS TPPA was used in the final evaluation. DBS TPPA showed an sensitivity of 95.5% (95% CI: 91.3–98.0%) and a specificity of 99.0% (95% CI: 98.1–99.5%) compared to TPPA using plasma samples as a reference. Conclusion DBS samples can be recommended for use with TPPA, and may be of value for external quality assurance of point-of-care syphilis testing.
Collapse
Affiliation(s)
- Pieter W Smit
- Leiden Cytology and Pathology Laboratory, Leiden, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Jori F, Vial L, Penrith ML, Pérez-Sánchez R, Etter E, Albina E, Michaud V, Roger F. Review of the sylvatic cycle of African swine fever in sub-Saharan Africa and the Indian ocean. Virus Res 2012; 173:212-27. [PMID: 23142551 DOI: 10.1016/j.virusres.2012.10.005] [Citation(s) in RCA: 102] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2012] [Revised: 10/05/2012] [Accepted: 10/06/2012] [Indexed: 11/17/2022]
Abstract
African swine fever (ASF) is a major limiting factor for pig production in most of the countries in Sub-Saharan Africa and the Indian Ocean. In the absence of vaccine, a good understanding of the ecology and epidemiology of the disease is fundamental to implement effective control measures. In selected countries of Southern and East Africa, the association between Ornithodoros moubata ticks and warthogs has been described in detail in the literature. However, for many other countries in the region, information related to the sylvatic cycle is lacking or incomplete. In West African countries, for instance, the role of wild pigs in the epidemiology of ASF has never been demonstrated and the existence and potential impact of a sylvatic cycle involving an association between soft ticks and warthogs is questionable. In other countries, other wild pig species such as the bushpigs (Potamochoerus spp.) can also be asymptomatically infected by the virus but their role in the epidemiology of the disease is unclear and might differ according to geographic regions. In addition, the methods and techniques required to study the role of wild hosts in ASF virus (ASFV) epidemiology and ecology are very specific and differ from the more traditional methods to study domestic pigs or other tick species. The aim of this review is (i) to provide a descriptive list of the methodologies implemented to study the role of wild hosts in African swine fever, (ii) to compile the available knowledge about the sylvatic cycle of ASFV in different regions of Sub-Saharan Africa and the Indian Ocean in addition to the one that has been described for East and Southern Africa, and (iii) to discuss current methodologies and available knowledge in order to identify new orientations for further field and experimental surveys.
Collapse
Affiliation(s)
- F Jori
- Cirad, AGIRs Research Unit, Campus International de Baillarguet, 34398 Montpellier, France.
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Montgomery ET, van der Pol B, van der Straten A, Ramjee G, de Bruyn G, Chipato T, Blanchard K, Padian NS. Discrepancies in diagnosis of incident HIV infection between antibody- and DNA-based tests in a phase III prevention trial in southern Africa. Int J STD AIDS 2012; 23:649-52. [DOI: 10.1258/ijsa.2009.009124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Dried blood spots (DBS) are widely used to test for HIV in a variety of research and service delivery settings; however, uniform guidelines regarding collection, storage and DNA extraction processes have neither been developed nor evaluated. Previously published reports suggested DBS may be stored at room temperature for up to 60 days, and intensive stability tests have shown that DBS can withstand high temperatures, humidity and freeze–thawing. During the implementation of a large randomized controlled trial (RCT) in southern Africa, with HIV acquisition as the primary endpoint, we observed 65 instances when DBS samples collected from the same day as a positive HIV antibody test yielded negative DNA polymerase chain reaction (PCR) results. The source of this discrepancy may have been due to inadequate specimen volume, filter paper or DNA extraction procedures, but were most likely due to storage conditions that have been reported as acceptable in other settings.
Collapse
Affiliation(s)
- E T Montgomery
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
| | - B van der Pol
- Indiana University School of Medicine, Infectious Disease Laboratory, Indianapolis, IN
| | - A van der Straten
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
- Center for AIDS Prevention Studies, Department of Medicine, University of California San Francisco, San Francisco, CA, USA
| | - G Ramjee
- Medical Research Council, Kwazulu-Natal
| | - G de Bruyn
- Perinatal HIV Research Unit, Johannesburg, South Africa
| | - T Chipato
- University of Zimbabwe-University of California San Francisco Research Collaborative Programme in Women's Health, Harare, Zimbabwe
| | - K Blanchard
- Ibis Reproductive Health, Cambridge, MA, USA
- Ibis Reproductive Health, Johannesburg, South Africa
| | - N S Padian
- Women's Global Health Imperative, RTI International, San Francisco Project Office, San Francisco, CA, USA
| | | |
Collapse
|
29
|
Kivuyo SL, Johannessen A, Trøseid M, Kasubi MJ, Gundersen SG, Naman E, Mushi D, Ngowi BJ, Mfinanga GS, Bruun JN. p24 antigen detection on dried blood spots is a feasible and reliable test for infant HIV infection in rural Tanzania. Int J STD AIDS 2012; 22:719-21. [PMID: 22174052 DOI: 10.1258/ijsa.2009.009382] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The difficulty of diagnosing HIV in infants is a major obstacle to early antiretroviral therapy (ART) in resource-limited settings. As serological tests are unreliable during the first 18 months of life, and the cost and complexity of polymerase chain reaction (PCR)-based assays limit their access in resource-limited settings, p24 antigen detection has emerged as an alternative diagnostic tool. In this study, the performance of an ultrasensitive p24 antigen assay on dried blood spots was evaluated under field conditions in rural Tanzania. Specimens were stored and shipped at tropical room temperature, and analysed within six weeks. In total, 27 consecutive children aged <18 months and exposed to vertical HIV transmission were enrolled. Overall sensitivity and specificity was 100% (95% confidence interval [CI], 47.8-100) and 95.5% (95% CI, 77.2-99.9), respectively. Our findings suggest that detection of p24 antigen on dried blood spots can be a reliable and feasible diagnostic tool for infant HIV infection in rural resource-limited settings.
Collapse
Affiliation(s)
- S L Kivuyo
- National Institute for Medical Research, Muhimbili Medical Research Centre, Dar es Salaam, Tanzania
| | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Wang J, Yiu B, Obermeyer J, Filipe CDM, Brennan JD, Pelton R. Effects of Temperature and Relative Humidity on the Stability of Paper-Immobilized Antibodies. Biomacromolecules 2012; 13:559-64. [PMID: 22257068 DOI: 10.1021/bm2017405] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Jingyun Wang
- Department of Chemical
Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4L7
| | - Brian Yiu
- Department of Chemical
Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, Canada N2L 3G1
| | - Jaclyn Obermeyer
- Department of Chemical
Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4L7
| | - Carlos D. M. Filipe
- Department of Chemical
Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4L7
| | - John D. Brennan
- Department of Chemistry
and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4M1
| | - Robert Pelton
- Department of Chemical
Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4L7
| |
Collapse
|
31
|
Anitha D, Jacob SM, Ganesan A, Sushi KM. Diagnosis of HIV-1 infection in infants using dried blood spots in Tamil Nadu, South India. Indian J Sex Transm Dis AIDS 2011; 32:99-102. [PMID: 22021971 DOI: 10.4103/0253-7184.85413] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Diagnosis of HIV infection in infants is difficult due to the presence of maternal antibodies; only nucleic acid assays are very helpful in early detection. Filter papers are especially useful for blood collection in resource-poor settings with limited access to diagnostic facilities. MATERIALS #ENTITYSTARTX00026; METHODS DBS samples were collected from the infants born to HIV seropositive mothers who had received single dose nevirapine at onset of labor. The samples were directly spotted onto the Whatman 903 cards from heel, big toe or finger prick depending on the age of the infants. A total of 766 infant samples were collected on dried blood spots (DBS) and transported to the Department of Experimental Medicine (DEM), Chennai, for testing from different government hospitals of rural and urban parts of Tamil Nadu, South India. According to National AIDS Control Organization's (NACO) protocol DNA was extracted from all these DBS and PCR was performed using the Roche kit version 1.5. RESULTS Fifteen infants were found to be HIV positive and 751 were HIV negative; all these 15 positive infants and 49 negative infants who were in the age group between 10 and 18 months were repeated with another DBS and compared with whole blood. The DBS results were concordant with the whole blood method and the sensitivity and specificity were 100%.
Collapse
Affiliation(s)
- D Anitha
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| | | | | | | |
Collapse
|
32
|
Usefulness of a genotypic resistance test using dried blood spot specimens in African HIV-infected children with virological failure according to the 2010-revised WHO criteria. Arch Virol 2011; 156:1603-6. [DOI: 10.1007/s00705-011-0997-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2011] [Accepted: 03/30/2011] [Indexed: 10/18/2022]
|
33
|
Dried blood spots in HIV monitoring: applications in resource-limited settings. Bioanalysis 2011; 2:1893-908. [PMID: 21083497 DOI: 10.4155/bio.10.120] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
By the end of 2008, 4 million people were receiving antiretroviral treatment for HIV/AIDS in low- and middle-income countries. In industrialized countries, monitoring of treatment with viral load measurements and drug resistance testing is the standard of care to ensure early detection of treatment failure and a prompt switch to a fully active second-line regimen, before drug-resistant mutations accumulate. These tests, however, require highly specialized laboratories and stringent procedures for storage and shipment of plasma, and are rarely available in resource-limited settings. Therefore, treatment failure in such settings is usually not detected until patients develop severe immunodeficiency, at which stage widespread resistance is likely. Dried blood spots (DBS) are easy to collect and store, and can be a convenient alternative to plasma in settings with limited laboratory capacity. This review provides an overview of possible applications of DBS technologies in the monitoring of HIV treatment, with the main focus on viral load quantification and drug resistance testing.
Collapse
|
34
|
Anitha D, Jacob SM, Ganesan A, Sushi KM. Diagnosis of HIV-1 infection in infants using dried blood spots in Tamil Nadu, South India. Indian J Sex Transm Dis AIDS 2011. [PMID: 22021971 PMCID: PMC3195190 DOI: 10.4103/2589-0557.85413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Diagnosis of HIV infection in infants is difficult due to the presence of maternal antibodies; only nucleic acid assays are very helpful in early detection. Filter papers are especially useful for blood collection in resource-poor settings with limited access to diagnostic facilities. MATERIALS #ENTITYSTARTX00026; METHODS DBS samples were collected from the infants born to HIV seropositive mothers who had received single dose nevirapine at onset of labor. The samples were directly spotted onto the Whatman 903 cards from heel, big toe or finger prick depending on the age of the infants. A total of 766 infant samples were collected on dried blood spots (DBS) and transported to the Department of Experimental Medicine (DEM), Chennai, for testing from different government hospitals of rural and urban parts of Tamil Nadu, South India. According to National AIDS Control Organization's (NACO) protocol DNA was extracted from all these DBS and PCR was performed using the Roche kit version 1.5. RESULTS Fifteen infants were found to be HIV positive and 751 were HIV negative; all these 15 positive infants and 49 negative infants who were in the age group between 10 and 18 months were repeated with another DBS and compared with whole blood. The DBS results were concordant with the whole blood method and the sensitivity and specificity were 100%.
Collapse
Affiliation(s)
- D. Anitha
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India,Address for correspondence: Dr D. Anitha, Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai – 600 032, India. E-mail:
| | - S. Mini Jacob
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| | - A. Ganesan
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| | - K. Mary Sushi
- Department of Experimental Medicine, The Tamil Nadu Dr. M G R Medical University, Chennai, India
| |
Collapse
|
35
|
Mei JV, Li L, Rasmussen SA, Collier S, Frias JL, Honein MA, Shaw GM, Lorey F, Meyer R, Chaing S, Canfield MA, Jones J, Hannon WH. Effect of specimen storage conditions on newborn dried blood spots used to assess Toxoplasma gondii immunoglobulin M (IgM). Clin Chim Acta 2010; 412:455-9. [PMID: 21114968 DOI: 10.1016/j.cca.2010.11.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2010] [Revised: 11/17/2010] [Accepted: 11/19/2010] [Indexed: 11/25/2022]
Abstract
BACKGROUND Newborn screening programs store-under varying conditions-residual dried blood spots (DBS). Residual DBS were used to investigate the contribution of congenital infection with Toxoplasma gondii to the etiology of hydrocephalus and as a key step, we assessed the effect of storage conditions on the stability of newborn screening biomarkers. METHODS Infants with hydrocephalus (410 cases) were identified using population-based birth defects surveillance systems in California, North Carolina, and Texas. Infants without birth defects (448 controls) were randomly selected from the same geographic areas and time periods. California stores DBS with controlled temperature, while North Carolina and Texas store DBS under ambient conditions. After removal of personal identifiers, DBS were tested for Toxo-specific immunoglobulin-M (Toxo-IgM). Because of poor elution of DBS stored in ambient conditions, additional biomarkers were tested on a specimen subset. RESULTS Among 858 DBS tested, Toxo-IgM was found in 3 cases and no controls from California (N=515) and in no specimens from North Carolina or Texas (N=343). Among the 98 specimens tested for selected biomarkers, statistically significant differences were found for California vs. combined North Carolina and Texas DBS (thyroid stimulating hormone, phenylalanine, methionine, leucine and citrulline p<0.0001; tyrosine and valine p<0.001). CONCLUSIONS Storage conditions for residual DBS had an effect on the ability to extract, recover, and accurately measure Toxo-IgM and other biomarkers from the filter paper matrix.
Collapse
Affiliation(s)
- Joanne V Mei
- Centers for Disease Control and Prevention, Atlanta, GA, United States.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Kim AA, McDougal JS, Hargrove J, Rehle T, Pillay-Van Wyk V, Puren A, Ekra A, Borget-Alloue MY, Adje-Toure C, Abdullahi AS, Odawo L, Marum L, Parekh BS. Evaluating the BED capture enzyme immunoassay to estimate HIV incidence among adults in three countries in sub-Saharan Africa. AIDS Res Hum Retroviruses 2010; 26:1051-61. [PMID: 20849299 DOI: 10.1089/aid.2009.0218] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Serological assays for estimating HIV-1 incidence are prone to misclassification, limiting the accuracy of the incidence estimate. Adjustment factors have been developed and recommended for estimating assay-based HIV-1 incidence in cross-sectional settings. We evaluated the performance of the recommended adjustment factors for estimating incidence in national HIV surveys in three countries in sub-Saharan Africa. The BED-capture enzyme immunoassay was applied to stored blood specimens from (1) pregnant women aged 15-49 years attending antenatal clinics in Côte d'Ivoire (1998-2004), (2) adults aged 15-49 years participating in a demographic health survey in Kenya (2003), and (3) adults aged 15-49 years participating in a national household serosurvey in South Africa (2005). Assay-derived incidence estimates were corrected for misclassification using recommended adjustment factors and, where possible, were compared to mathematically modeled incidence in the same populations. Trends in HIV prevalence were compared to trends in assay-derived incidence to assess plausibility in the assay-derived trends. Unadjusted incidence was 3.8% [95% confidence interval (CI) 3.3-4.5] in Côte d'Ivoire, 3.5% (2.7-4.3) in Kenya, and 4.4% (CI 2.3-6.5]) in South Africa. Adjusted incidence was 2.9% (CI 2.1-3.7) in Côte d'Ivoire, 2.6% (CI 2.0-3.2) in Kenya, and 2.4% (CI 1.7-3.1) in South Africa. After adjustment, peak incidence shifted from older to younger age groups in Côte d'Ivoire and South Africa. Modeled HIV incidence was 1.0% (CI 1.02-1.08) in Kenya and 2.0% (CI 1.7-2.4) in South Africa. After applying the recommended adjustments factors, adjusted assay-derived estimates remained implausibly high in two of three populations evaluated. For more accurate measures of assay-derived population incidence, adjustment factors must be locally derived and validated. Until improved assays are available, caution should be applied in the use and interpretation of data from incidence assays.
Collapse
Affiliation(s)
- Andrea A. Kim
- Global AIDS Program, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia
| | | | - John Hargrove
- DST/NRF Centre of Excellence in Epidemiological Modeling and Analysis, SACEMA, Stellenbosch, South Africa
| | - Thomas Rehle
- Human Sciences Research Council, Cape Town, South Africa
| | - Victoria Pillay-Van Wyk
- Human Sciences Research Council, Cape Town, South Africa
- Medical Research Council, Cape Town, South Africa
| | - Adrian Puren
- National Institute for Communicable Diseases, Johannesburg, South Africa
| | - Alexandre Ekra
- Global AIDS Program Côte d'Ivoire, U.S. Centers for Disease Control and Prevention, Abidjan, Côte d'Ivoire
| | | | - Christiane Adje-Toure
- Global AIDS Program Côte d'Ivoire, U.S. Centers for Disease Control and Prevention, Abidjan, Côte d'Ivoire
| | | | - Linus Odawo
- Global AIDS Program Kenya, US Centers for Disease Control and Prevention, Nairobi, Kenya
| | - Lawrence Marum
- Global AIDS Program Kenya, US Centers for Disease Control and Prevention, Nairobi, Kenya
| | - Bharat S. Parekh
- Global AIDS Program, Centers for Disease Control and Prevention (CDC), Atlanta, Georgia
| |
Collapse
|
37
|
Lira R, Maldonado-Rodriguez A, Rojas-Montes O, Ruiz-Tachiquin M, Torres-Ibarra R, Cano-Dominguez C, Valdez-Salazar H, Gomez-Delgado A, Muñoz O, Alvarez-Muñoz MT. Use of dried blood samples for monitoring hepatitis B virus infection. Virol J 2009; 6:153. [PMID: 19788743 PMCID: PMC2761391 DOI: 10.1186/1743-422x-6-153] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2009] [Accepted: 09/29/2009] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Hepatitis B virus (HBV) infection is a problem in several regions of the world with limited resources. Blood samples dried on filter paper (DBS) have been successfully used to diagnose and monitor several infectious diseases. In Mexico there is an urgent need for an affordable and easy sampling method for viral load (VL) testing and monitoring of chronic HBV infection. The purpose of this work was to validate the utility of DBS samples for monitoring HBV infection in patients from Mexico City. METHODS Matched samples of plasma and DBS on filter paper from 47 HBV infected patients from the Instituto Mexicano del Seguro Social (IMSS), were included. To evaluate the DNA stability and purity from DBS stored at different temperature conditions, samples from ten patients were stored at 4 degree, 25 degree, and 37 degree C for 7 days. After DBS elution and DNA extraction, the purity of these samples was determined measuring the O.D. rate 260/280. The DBS utility for molecular studies was assessed with PCR assays to amplify a 322 bp fragment from the "a" determinant region of the HBV "S" gene. The VL from all samples was determined to evaluate the correlation between plasma and DBS matched samples. RESULTS The quality of the DNA from DBS specimen is not adversely affected by storage at 4 degree, 25 degree and 37 degree C for up 7 days. Statistical ANOVA analyses did not show any significant difference. The same amplification efficiency was observed between DNA templates from samples stored at different temperatures. The Pearson correlation between the VL from DBS and plasma matched samples was 0.93 (p = 0.01). The SD was 1.48 for DBS vs.1.32 for Plasma, and an average of log10 copies/mL of 5.32 vs. 5.53. ANOVA analysis did not show any statistically significant difference between the analyzed groups (p = 0.92). CONCLUSION The results provide strong evidence that the isolation and quantification of DNA-HBV from DBS is a viable alternative for patient monitoring, and molecular characterization of the virus variants circulating in Mexico.
Collapse
Affiliation(s)
- Rosalia Lira
- Unidad de Investigacion Medica en Enfermedades Infecciosas y Parasitarias, Hospital de Pediatria, Centro Medico Nacional Siglo XXI, Instituto Mexicano del Seguro Social, Cuauhtemoc 330 Col, Doctores, Delegacion Cuauhtemoc, Mexico City, Mexico.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Ikomey GM, Atashili J, Okomo-Assoumou MC, Mesembe M, Ndumbe PM. Dried blood spots versus plasma for the quantification of HIV-1 RNA using the manual (PCR-ELISA) amplicor monitor HIV-1 version 1.5 assay in Yaounde, Cameroon. ACTA ACUST UNITED AC 2009; 8:181-4. [PMID: 19357423 DOI: 10.1177/1545109709333111] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Considering the recent accrued need for viral load quantification in resource-limited settings, this study evaluated the use of dried blood spots (DBS) compared to plasma as a means of sample collection and storage for HIV-1 RNA quantification using a non-automated assay. METHODS Venous blood was collected from 60 consenting HIV-1-positive patients, plasma separated within 4 hours, and stored at -20 degrees C. Venous blood, 50 microL, was blotted on 4 designated areas of Whatman filter paper and air-dried at room temperature for 2 hours. RESULTS There was a strong statistically significant correlation between HIV-1 RNA viral load using plasma and DBS (r = .955, P < .001). On average plasma viral loads were only slightly higher than DBS viral loads (mean difference: 0.06 log(10) copies/mL). CONCLUSION Even when using an entirely manual HIV-quantification assay, DBS may provide a reliable, cost-effective method for sample collection and storage for HIV-1 RNA quantification in resource-limited settings.
Collapse
Affiliation(s)
- G M Ikomey
- Center for the Study and Control of Communicable Diseases (CSCCD), Faculty of Medicine and Biomedical Sciences, University of Yaounde I, Cameroon
| | | | | | | | | |
Collapse
|
39
|
Lakshmi V, Sudha T, Dandona R, Teja VD, Kumar GA, Dandona L. Application of human immunodeficiency virus type 1 BED enzyme immunoassay on dried blood spots in India. J Med Microbiol 2009; 58:312-317. [DOI: 10.1099/jmm.0.005249-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Dried blood spots (DBSs) on filter paper are being used increasingly in population-based human immunodeficiency virus (HIV) studies. This study evaluated the application of a BED enzyme immunoassay (EIA) on DBSs to estimate HIV incidence in a population-based study in India. The Calypte HIV-1 BED Incidence EIA was performed on 224 HIV-1-positive DBS samples, after screening 12 617 individuals from a population-based sample in Guntur district in the southern Indian state of Andhra Pradesh. The number of recently infected HIV cases was identified using this BED assay and was used to estimate the annual HIV incidence rate based on calculations and adjustment formulae suggested by the Centers for Disease Control and Prevention (CDC). The updated BED data management software provided by the CDC was used for analyses. Of the 224 HIV-1 antibody-positive DBS samples, 29 (12.95 %) were estimated by the BED HIV-1 assay to have been infected within the past 155 days. After adjusting for age, gender and rural/urban distribution of the population, the annual incidence rate of HIV-1 infection was estimated to be 0.32 % (95 % confidence interval 0.20–0.44 %). This annual incidence was 18.6 % of the HIV prevalence of 1.72 % in this study. Thus, the BED assay revealed a higher incidence of HIV in this study than was expected from the prevalence. Correlation of the BED assay with panel testing and longitudinal incidence data in the Indian population is needed to calibrate it for use in India.
Collapse
Affiliation(s)
- Vemu Lakshmi
- Department of Microbiology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Talasila Sudha
- Department of Microbiology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - Rakhi Dandona
- School of Public Health and George Institute for International Health, University of Sydney, Sydney, Australia
- Health Studies Area, Administrative Staff College of India, Hyderabad, India
- George Institute for International Health – India, Hyderabad, India
| | - Vijay D. Teja
- Department of Microbiology, Nizam's Institute of Medical Sciences, Hyderabad, India
| | - G. Anil Kumar
- Health Studies Area, Administrative Staff College of India, Hyderabad, India
- George Institute for International Health – India, Hyderabad, India
| | - Lalit Dandona
- School of Public Health and George Institute for International Health, University of Sydney, Sydney, Australia
- Health Studies Area, Administrative Staff College of India, Hyderabad, India
- George Institute for International Health – India, Hyderabad, India
| |
Collapse
|
40
|
Chaillet P, Zachariah R, Harries K, Rusanganwa E, Harries AD. Dried blood spots are a useful tool for quality assurance of rapid HIV testing in Kigali, Rwanda. Trans R Soc Trop Med Hyg 2009; 103:634-7. [PMID: 19249069 DOI: 10.1016/j.trstmh.2009.01.023] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2008] [Revised: 01/27/2009] [Accepted: 01/27/2009] [Indexed: 11/26/2022] Open
Abstract
A study was conducted in two primary health facilities in Kigali, Rwanda, to determine whether dried blood spots (DBS) used for quality control of HIV testing would give comparable results with serum after being stored for a period of 14 days and 30 days at ambient temperature. DBS and serum specimens were collected from patients undergoing HIV testing. ELISA performed on serum at baseline (gold standard) was compared with DBS results. The study included a total of 491 patients, comprising 92 (19%) males and 399 (81%) females with a median age of 27 years. A total of 148 individuals (30%) were HIV-positive. The average ambient temperature under which DBS specimens were stored at the health facilities was 23 degrees C (range 18-25 degrees C). The kappa statistic at 14 days and 30 days was 0.99 (99.4% agreement) and 0.98 (99.2% agreement), respectively, signifying almost 'perfect agreement (P<0.001)' with the gold standard. In a resource-limited sub-Saharan African country embarking on scaling-up of HIV testing, DBS stored at ambient conditions for up to 1 month were found to be a useful and robust tool to perform quality control of rapid HIV testing at the health centre level.
Collapse
Affiliation(s)
- P Chaillet
- Médecins sans Frontières, Medical Department, Brussels Operational Center, Belgium
| | | | | | | | | |
Collapse
|
41
|
Diminished human immunodeficiency virus type 1 DNA yield from dried blood spots after storage in a humid incubator at 37 degrees C compared to -20 degrees C. J Clin Microbiol 2008; 46:2945-9. [PMID: 18614660 DOI: 10.1128/jcm.00359-08] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Collecting whole blood on filter paper simplifies the processing, transport, and storage of specimens used for the diagnosis of human immunodeficiency virus type 1 (HIV-1) and other tests. Specimens may be collected in tropical or rural areas with minimal facilities for handling specimens. To compare simulated tropical conditions with freezer storage, we examined the stability of HIV-1 DNA in dried blood spots (DBS) stored in humid heat and at -20 degrees C. DBS were created by spotting 50-microl aliquots of whole blood on 903 filter paper. DNA was extracted from DBS at baseline and after 2, 6, or 12 months of storage at -20 degrees C or at 37 degrees C with approximately 85% humidity. The DNA was tested undiluted or diluted using the Amplicor HIV-1 DNA PCR (Roche), version 1.5. Each reaction was scored positive, negative, or indeterminate based on optical density. Results were compared between storage conditions and over time. A total of 1,832 reactions from 916 DBS were analyzed, including 100 DBS at baseline, 418 stored at -20 degrees C, and 398 stored at 37 degrees C. A chi-square test showed fewer positive reactions for DBS stored at 37 degrees C (55%) than for those stored at -20 degrees C (78%) (P < 0.0001). Samples stored at -20 degrees C showed little change in the probability of detection of HIV-1 DNA over time; the odds ratio (OR) was 0.93 after storage for 1 year. Samples stored at 37 degrees C demonstrated a significant change in detection at 1 year (OR, 0.29). We conclude that exposure of DBS to 37 degrees C and high humidity impaired the recovery of HIV-1 DNA from DBS, whereas DNA recovery was preserved when DBS were stored frozen.
Collapse
|
42
|
Dried-blood sampling for epstein-barr virus immunoglobulin G (IgG) and IgA serology in nasopharyngeal carcinoma screening. J Clin Microbiol 2008; 46:1374-80. [PMID: 18256216 DOI: 10.1128/jcm.01368-07] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Dried-blood (DB) samples on filter paper are considered clinical specimens for diagnostic use because of the ease of collection, storage, and transport. We recently developed a synthetic-peptide-based immunoglobulin A (IgA) (EBNA1 plus viral capsid antigen [VCA]-p18) enzyme-linked immunosorbent assay (ELISA) for nasopharyngeal carcinoma (NPC) screening. Here, we evaluate the use of two filter papers for DB sampling, i.e., Schleicher & Schuell (S&S) no. 903 and Whatman no. 3; the DB samples were either taken directly from a finger prick or spotted from a Vacutainer blood collector. The elution of DB samples on filter paper was optimized and tested for IgG and IgA reactivity by ELISA (EBNA1 plus VCA-p18) and compared to simultaneously collected plasma samples. The results showed that both types of filter paper can be used for sample collection in NPC diagnosis by using either finger prick or blood spot sampling. Both DB sampling methods produced comparable ELISA (EBNA1 plus VCA-p18) results for IgG and IgA reactivity in 1:100-diluted plasma samples. DB samples of whole blood or finger prick blood show correlation coefficients (r(2)) of 0.825 to 0.954 for IgA on S&S no. 903 filter paper, 0.9133 to 0.946 for IgA on Whatman no. 3 filter paper, 0.807 to 0.886 for IgG on S&S no. 903 filter paper, and 0.819 to 0.934 for IgG on Whatman no. 3 filter paper. Using plasma IgA as a reference, DB sampling showed sensitivities and specificities of 75.0 to 96.0% and 93.5 to 100%, respectively. DB samples could be stored at 37 degrees C for 1 to 4 weeks on S&S no. 903 filter paper and 1 to 6 weeks on Whatman no. 3 filter paper without a significant loss of reactivity, with provision of transport options for tropical conditions. IgA proved to be more stable than IgG. Whatman no. 3 filter paper is a more economical yet diagnostically comparable alternative to S&S no. 903 filter paper. Finger prick DB sampling is proposed for NPC diagnosis, particularly for remote hospitals and field screening studies.
Collapse
|
43
|
Evaluation of the ultrasensitive human immunodeficiency virus type 1 (HIV-1) p24 antigen assay performed on dried blood spots for diagnosis of HIV-1 infection in infants. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2007; 15:388-91. [PMID: 18057183 DOI: 10.1128/cvi.00265-07] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The diagnostic accuracy of the modified p24 antigen assay performed on pediatric dried blood spots was evaluated. Samples analyzed within 6 weeks of collection yielded no false-positive results (specificity, 100%) and few false-negative results (sensitivity, 96.5% to 98.3%). Laboratory services with limited resources should assess this option for routine infant diagnosis.
Collapse
|
44
|
Michaud V, Gil P, Kwiatek O, Prome S, Dixon L, Romero L, Le Potier MF, Arias M, Couacy-Hymann E, Roger F, Libeau G, Albina E. Long-term storage at tropical temperature of dried-blood filter papers for detection and genotyping of RNA and DNA viruses by direct PCR. J Virol Methods 2007; 146:257-65. [PMID: 17714797 DOI: 10.1016/j.jviromet.2007.07.006] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2006] [Revised: 07/06/2007] [Accepted: 07/10/2007] [Indexed: 11/22/2022]
Abstract
In tropical countries the diagnosis of viral infections of humans or animals is often hampered by the lack of suitable clinical material and the necessity to maintain a cold chain for sample preservation up to the laboratory. This study describes the use of filter papers for rapid sample collection, and the molecular detection and genotyping of viruses when stored over long periods at elevated temperatures. Infected blood was collected on filter papers, dried and stored at different temperatures (22, 32 and 37 degrees C) for various periods (up to 9 months). Two animal viruses, African swine fever, a large double-stranded DNA virus and Peste des Petits Ruminants, a negative single-stranded RNA virus, were used to validate the method. Filter papers with dried blood containing virus or control plasmid DNA were cut in small 5mm(2) pieces and added directly to the PCR tube for conventional PCR. Nucleic acid from both viruses could still be detected after 3 months at 32 degrees C. Moreover, the DNA virus could be detected at least 9 months after conservation at 37 degrees C. PCR products obtained from the filter papers were sequenced and phylogenetic analysis carried out. The results were consistent with published sequences, demonstrating that this method can be used for virus genotyping.
Collapse
Affiliation(s)
- V Michaud
- CIRAD, UR Contrôle des Maladies, Montpellier F-34398, France
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Lakshmi V, Sudha T, Bhanurekha M, Dandona L. Evaluation of the Murex HIV Ag/Ab Combination assay when used with dried blood spots. Clin Microbiol Infect 2007; 13:1134-6. [PMID: 17725648 DOI: 10.1111/j.1469-0691.2007.01809.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This study evaluated the ability of the Murex HIV Ag/Ab Combination assay to detect human immunodeficiency virus (HIV) antibodies in 12 617 dried blood spots (DBSs) on filter paper. The assay had an overall sensitivity of 99.6% and a specificity of 99.9%. In view of its ability to detect p24 antigen and both HIV-1 and HIV-2 antibodies in samples collected in the form of DBSs, the Murex Ag/Ab Combination assay is suitable for use as a standard screening assay for seroprevalence studies, as well as for routine diagnostic use in clinical laboratories.
Collapse
Affiliation(s)
- V Lakshmi
- Department of Microbiology, Nizam's Institute of Medical Sciences, Punjagutta, Hyderabad, India.
| | | | | | | |
Collapse
|
46
|
Opstelten W, van Loon AM, Schuller M, van Wijck AJM, van Essen GA, Moons KGM, Verheij TJM. Clinical diagnosis of herpes zoster in family practice. Ann Fam Med 2007; 5:305-9. [PMID: 17664496 PMCID: PMC1934966 DOI: 10.1370/afm.707] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Family physicians usually diagnose herpes zoster on clinical grounds only, possibly resulting in false-positive diagnoses and unnecessary treatment. We wanted to determine the positive predictive value of the physicians' judgment in diagnosing herpes zoster and to assess the applicability of dried blood spot analysis for diagnosis of herpes zoster in family practice. METHODS Our study population consisted of 272 patients older than 50 years with herpes zoster (rash for less than 7 days). Dried blood spot samples were collected from all patients and sent by mail to the laboratory. Baseline measurements included clinical signs (localization, severity, and duration of rash) and symptoms (duration and severity of pain). Varicella-zoster virus antibodies were determined at baseline and 5 to 10 days later. Multivariate logistic regression was used to assess independent associations between clinical variables and serological confirmation of herpes zoster. RESULTS Dried blood spot analysis was possible in 260 patients (96%). In 236 the diagnosis of herpes zoster was confirmed serologically (positive predictive value of clinical judgment 90.8%; 95% confidence interval, 87.3%-94.3%). Independent clinical variables for serologically confirmed herpes zoster were severity and duration of rash at first examination. CONCLUSION Family physicians have good clinical judgment when diagnosing herpes zoster in older patients. Dried blood spot analysis is a logistically convenient method for serological investigation of patients in family practice, but it is rarely needed for diagnosing herpes zoster.
Collapse
Affiliation(s)
- Wim Opstelten
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
47
|
Knuchel MC, Jullu B, Shah C, Tomasik Z, Stoeckle MP, Speck RF, Nadal D, Mshinda H, Böni J, Tanner M, Schüpbach J. Adaptation of the ultrasensitive HIV-1 p24 antigen assay to dried blood spot testing. J Acquir Immune Defic Syndr 2007; 44:247-53. [PMID: 17146373 DOI: 10.1097/qai.0b013e31802c3e67] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Implementation of molecular tests for the assessment of pediatric HIV-1 infection in resource-limited countries is difficult because of technical complexity and costs. Alternatives like the ultrasensitive HIV-1 p24 antigen enzyme-linked immunosorbent assay have therefore been proposed. We have now adapted this test to dried blood spot (DBS) plasma p24 antigen (p24). High background activity was recognized as originating from endogenous peroxidase and eliminated by H2O2 quenching. The assay was evaluated with 72 pediatric specimens from Tanzania and with 210 pediatric or adult specimens from Switzerland. A real-time polymerase chain reaction assay for DBS DNA and/or plasma RNA identified HIV-1 infection in 38 Tanzanian children. HIV-1 subtypes included 18 C, 9 A1, 8 D, 1 AC, 1 J-like, and 1 unidentified. The detection rates for the different assays were as follows: DBS-p24, 32 (84%) of 38 samples; DBS DNA, 30 (79%) of 38 samples; plasma-p24, 23 (85%) of 27 samples; and plasma RNA, 30 (100%) of 30 samples. False-negative DBS-p24 was associated with subtype D (P < 0.01). DBS-p24 detection for non-D subtypes was 93% (95% confidence interval: 81% to 99%), and for subtype C, it was 94% (95% confidence interval: 76% to 99%). Specificity among 193 HIV-negative DBS samples was 100%. Correlation of DBS-p24 and plasma-p24 concentrations was excellent (R = 0.83, P < 0.0001). DBS-p24 is thus a promising alternative to molecular tests for HIV-1 in subtype C regions. It should now be evaluated in large studies of children for accurate assessment of diagnostic sensitivity.
Collapse
Affiliation(s)
- Marlyse C Knuchel
- Swiss National Centre for Retroviruses, University of Zürich, Gloriastrasse 30/32, CH-8006 Zürich, Switzerland
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Sarge-Njie R, Schim Van Der Loeff M, Ceesay S, Cubitt D, Sabally S, Corrah T, Whittle H. Evaluation of the dried blood spot filter paper technology and five testing strategies of HIV-1 and HIV-2 infections in West Africa. ACTA ACUST UNITED AC 2007; 38:1050-6. [PMID: 17148076 DOI: 10.1080/00365540600801645] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Simple robust approaches are needed to monitor the prevalence and incidence of HIV in Africa. The aim of this study was to evaluate the use of dried blood spot (DBS) as an alternative to serum or plasma for sentinel surveillance. Paired DBS and blood samples were obtained from 200 patients attending a genito-urinary medicine clinic in West Africa. The gold standard of diagnosis was based on the combination of 3 enzyme-linked immunosorbent assays (ELISA) using serum. The presence of HIV antibodies in eluates of dried blood spots was detected by ELISA, Gelatin Particle Assay (GPA) and Pepti-Lav 1-2 in 5 different testing strategies. All 200 eluates were tested individually, and in addition pools of 5 eluates each were tested. The sensitivity of the testing strategies ranged from 95.0% (83.1 - 99.4%) to 100% and the specificity from 97.5% (93.7 - 99.3%) to 100%. Testing in pools of 5 did not affect sensitivity. Dried blood spots were easy to work with. Test kit and laboratory consumable costs varied between 492 pounds and 1037 pounds (unpooled strategies) and 163 pounds and 421 pounds (pooled). The monospecific ELISAs used in this study are no longer in production; currently available differentiating assays need to be tested. DBS are recommended for sentinel surveillance in Africa.
Collapse
|
49
|
Ayele W, Schuurman R, Messele T, Dorigo-Zetsma W, Mengistu Y, Goudsmit J, Paxton WA, de Baar MP, Pollakis G. Use of dried spots of whole blood, plasma, and mother's milk collected on filter paper for measurement of human immunodeficiency virus type 1 burden. J Clin Microbiol 2007; 45:891-6. [PMID: 17251400 PMCID: PMC1829137 DOI: 10.1128/jcm.01919-06] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
We studied the use of dried spots of bodily fluids (plasma, whole blood, and mother's milk) on filter paper as a means of sample collection and storage for human immunodeficiency virus type 1 (HIV-1) viral load testing under stringent field conditions. Plasma placed directly in lysis buffer, which is customarily used for viral load assays, was used for comparison in all our experiments. Utilizing reconstruction experiments, we demonstrate no statistical differences between viral loads determined for plasma and mother's milk spotted on filter paper and those for the same fluids placed directly in lysis buffer. We found that the addition of whole blood directly to lysis buffer was unreliable and could not be considered a feasible option. However, viral load measurements for whole blood spotted onto filter paper correlated with plasma viral load values for both filter spots and lysis buffer (Pearson correlation coefficients, 0.7706 and 0.8155, respectively). In conclusion, dried spots of plasma, whole blood, or mother's milk provide a feasible means for the collection, storage, and shipment of samples for subsequent viral load measurement and monitoring. Virus material spotted and dried on filter paper is a good inexpensive alternative for collecting patient material to monitor the HIV-1 viral load. Measuring the HIV-1 burden from whole blood dried on filter paper provides a suitable alternative for low-technology settings with limited access to refrigeration, as can be found in sub-Saharan Africa.
Collapse
Affiliation(s)
- Workenesh Ayele
- Ethio-Netherlands AIDS Research Project, Addis Ababa, Ethiopia
| | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Handali S, Rodriguez S, Noh J, Gonzalez AE, Garcia HH, Gilman RH, Roberts JM, Hancock K, Tsang VCW. A simple method for collecting measured whole blood with quantitative recovery of antibody activities for serological surveys. J Immunol Methods 2007; 320:164-71. [PMID: 17270207 DOI: 10.1016/j.jim.2006.12.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2006] [Revised: 10/31/2006] [Accepted: 12/18/2006] [Indexed: 11/20/2022]
Abstract
Compliance and acceptance for the finger-prick method of blood collection is generally better than for venipuncture. A finger-prick method of blood collection with quantitative antibody recovery is even more important for seroepidemiological surveys. Finger-prick blood collected and dried onto filter paper has been used; but, unfortunately, this method has several disadvantages, including loss of antibody activity, possible contact contamination from blood spots on adjacent filter papers, and difficulties in extracting antibodies, justifying the search for other methods of collecting and transporting blood samples. We report on a simple method of collecting a measured amount of finger-prick blood onto a sample pad, which is immediately transferred to storage/extraction buffer. The diluted blood sample is never dried, and because of the storage buffer, can be transported and stored without refrigeration. Furthermore, the diluted blood samples can then be tested directly without further preparation. We systematically compared several storage/extraction buffers and commercially available filter papers. We showed that antibody recovery was not significantly affected by the type of filter papers used but was significantly affected by the storage/extraction buffer used. The best such buffer is StabilZyme Select.
Collapse
Affiliation(s)
- Sukwan Handali
- Division of Parasitic Diseases, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, GA, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|