1
|
Almada DL, Alves ADR, Leon LAA, Macedo DFR, de Oliveira SA, Siqueira MM, Brown D, Cubel Garcia RDCN. Use of oral fluid samples for the investigation of outbreaks of human parvovirus B19 infection. Braz J Microbiol 2022; 53:1959-1967. [PMID: 36149627 PMCID: PMC9679058 DOI: 10.1007/s42770-022-00828-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 09/08/2022] [Indexed: 01/13/2023] Open
Abstract
The use of oral fluid (OF) samples for serological diagnosis of parvovirus B19 infection during outbreaks of erythema infectiosum had already been demonstrated, but the feasibility of using OF for the characterization of B19 genotypes circulating during outbreaks has not been described. The aim of this study was to assess the use of "in-house" PCR-based assays as a powerful tool for a rapid diagnosis and molecular characterization of B19 strains in OF samples during outbreaks. Paired serum and OF samples collected from anti-B19 IgM-positive patients, during two outbreaks of ertythema infectiosum (1999-2000 and 2004-2005), were tested by conventional (cPCR) and quantitative PCR (qPCR). qPCR was more sensitive than cPCR for detecting B19-DNA in both OF and serum. Overall, OF presented lower viral load (9.97 × 106 UI/mL) than serum (2.42 × 1010 UI/mL) and this difference was statistically significant. All OF samples obtained from patients in the age group < 14 years presented low viral load (< 104 IU/mL). No correlation was found between viral load and the number of days of onset of rash. Sequence analysis from PCR positive OF samples confirmed the circulation of subgenotype 1a (G1a) during these outbreaks. Our findings indicate that PCR-based assays may fail to detect B19-DNA in approximately 50% of OF compared to serum samples. Nevertheless, our study has shown for the first time that the genome sequence of the amplicon from non-invasive clinical sample is useful for molecular genotyping and may be a tool to clarify the genetic diversity of B19 strains circulating in distinct outbreaks.
Collapse
Affiliation(s)
- Daiana Lima Almada
- Departamento de Microbiologia e Parasitologia, Instituto Biomédico, Universidade Federal Fluminense, Niterói, RJ, Brazil
| | - Arthur Daniel Rocha Alves
- Laboratório de Desenvolvimento Tecnológico em Virologia, Instituto Oswaldo Cruz, Fundação Oswaldo Cruz, Rio de Janeiro, RJ, Brazil
| | - Luciane Almeida Amado Leon
- Laboratório de Desenvolvimento Tecnológico em Virologia, Instituto Oswaldo Cruz, Fundação Oswaldo Cruz, Rio de Janeiro, RJ, Brazil
| | | | - Solange Artimos de Oliveira
- Serviço de Infectologia do Hospital Universitário Antônio Pedro, Universidade Federal Fluminense, Niterói, RJ, Brazil
| | - Marilda Mendonça Siqueira
- Laboratório de Vírus Respiratórios e do Sarampo, Instituto Oswaldo Cruz, Fundação Oswaldo Cruz, Rio de Janeiro, RJ, Brazil
| | - David Brown
- Laboratório de Vírus Respiratórios e do Sarampo, Instituto Oswaldo Cruz, Fundação Oswaldo Cruz, Rio de Janeiro, RJ, Brazil
| | | |
Collapse
|
2
|
Cnc Garcia RD, Leon LA. Human parvovirus B19: a review of clinical and epidemiological aspects in Brazil. Future Microbiol 2021; 16:37-50. [PMID: 33438475 DOI: 10.2217/fmb-2020-0123] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Since the first evidence of human parvovirus B19 (B19V) infection in late 80s, several studies have been conducted to clarify the spectrum of clinical diseases in Brazil. B19V infection is prevalent in the general population and has exhibited a cyclical pattern of occurrence every 4-5 years, with the predominance of genotype 1 over 3b. During epidemic periods the wide range of clinical conditions, such as ertythema infectiosum, arthropathy, transient aplastic crisis, nonimmune hydrops fetalis and B19V-hepatitis were diagnosed. However, many infections are likely asymptomatic or have a self-limiting clinical course and are not readly diagnosed. Besides, the similarity of the symptoms of ertythema infectiosum to other rash diseases and the broadly circulation of arboviruses makes differential diagnosis more difficult. In this article, we provide a historical comprehensive overview of the research on parvovirus B19 conducted in Brazil, with a focus on the clinical and epidemiological aspects of the infection.
Collapse
Affiliation(s)
- Rita de Cnc Garcia
- Departamento de Microbiologia e Parasitologia, Instituto Biomédico, Universidade Federal Fluminense (UFF), Rua Professor Hernani Melo 101, Niterói, RJ 22430 190, Brazil
| | - Luciane Aa Leon
- Laboratório de Desenvolvimento Tecnológico em Virologia, Instituto Oswaldo Cruz, Fundação Oswaldo Cruz, Avenida Brasil 4365, Manguinhos, RJ 21040 360, Brazil
| |
Collapse
|
3
|
Serología en el siglo xxi: ¿continúa teniendo interés? Enferm Infecc Microbiol Clin 2019; 37 Suppl 1:40-46. [DOI: 10.1016/s0213-005x(19)30181-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
4
|
Abstract
Parvovirus B19 (B19V) and human bocavirus 1 (HBoV1), members of the large Parvoviridae family, are human pathogens responsible for a variety of diseases. For B19V in particular, host features determine disease manifestations. These viruses are prevalent worldwide and are culturable in vitro, and serological and molecular assays are available but require careful interpretation of results. Additional human parvoviruses, including HBoV2 to -4, human parvovirus 4 (PARV4), and human bufavirus (BuV) are also reviewed. The full spectrum of parvovirus disease in humans has yet to be established. Candidate recombinant B19V vaccines have been developed but may not be commercially feasible. We review relevant features of the molecular and cellular biology of these viruses, and the human immune response that they elicit, which have allowed a deep understanding of pathophysiology.
Collapse
Affiliation(s)
- Jianming Qiu
- Department of Microbiology, Molecular Genetics and Immunology, University of Kansas Medical Center, Kansas City, Kansas, USA
| | | | - Neal S Young
- Hematology Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
5
|
Mercader S, Featherstone D, Bellini WJ. Comparison of available methods to elute serum from dried blood spot samples for measles serology. J Virol Methods 2006; 137:140-9. [PMID: 16860401 DOI: 10.1016/j.jviromet.2006.06.018] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2006] [Revised: 06/08/2006] [Accepted: 06/13/2006] [Indexed: 11/18/2022]
Abstract
Six existing protocols for the extraction of serum from blood spots dried onto filter paper were compared. Assessment criteria included: detection of measles IgM and IgG by the Dade Behring Enzygnost immunoassays, volumes of recovered eluates, reproducibility, processing time and throughput, difficulty of protocol, equipment required, safety and estimated costs. Detection of measles IgM in eluates obtained by four of these protocols was as in serum, and significant differences were only observed in eluates from the two remaining protocols (p < 0.05). Significant differences were found between extraction protocols regarding measles-specific IgG detection when an IgG indeterminate DBS was analyzed (p < 0.05), but not when an IgG positive and negative DBS were studied. Sufficient eluate volumes were recovered for testing in the IgM Behring assay following all protocols but two. Sufficient eluate was recovered for testing in the IgG Behring assay following all six protocols. While all protocols were relatively easy to perform, only two protocols required less than 2h for completion. In general, compared protocols performed well on the extraction of antibodies from DBS for serology with differences being observed with eluate volume recovery, turn around time, required equipment and cost. An easy-to-implement protocol is proposed for the rapid extraction of serum for measles/rubella serology in outbreak situations for use in the World Health Organization Global Measles and Rubella Laboratory Network.
Collapse
Affiliation(s)
- Sara Mercader
- Measles, Mumps, Rubella and Herpes Viruses Branch, Division of Viral Diseases, National Center for Immunization and Respiratory Diseases, Centers for Disease Control and Prevention, 1600 Clifton Road, M.S. C-22, Atlanta, GA 30333, USA.
| | | | | |
Collapse
|
6
|
Tapia MD, Pasetti MF, Cuberos L, Sow SO, Doumbia MN, Bagayogo M, Kotloff KL, Levine MM. Measurement of tetanus antitoxin in oral fluid: a tool to conduct serosurveys. Pediatr Infect Dis J 2006; 25:819-25. [PMID: 16940841 DOI: 10.1097/01.inf.0000232629.72160.bb] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Serosurveys that measure tetanus antitoxin can complement immunization coverage surveys to allow evaluation of immunization services in developing countries. Measurement of IgG tetanus antitoxin in oral fluid was investigated as a practical and noninvasive alternative to and correlate of serum antibodies. METHODS Serum and oral fluid were collected from Malian infants, toddlers and adults (males without a history of tetanus vaccination). Specific IgG tetanus antitoxin was measured by enzyme-linked immunosorbent assay in serum (S-ELISA) and oral fluid (OF-ELISA). RESULTS One hundred forty-two pairs of serum and oral fluid samples were collected from infants, 35 pairs from toddlers and 35 pairs from adults. IgG tetanus antitoxin titers measured by OF-ELISA were 100-fold lower than those measured by S-ELISA but they correlated strongly (r = 0.90, P < 0.001). All 35 toddlers who had received 2 or 3 doses of diphtheria-tetanus-pertussis (DTP) vaccine (100%) had serum tetanus antitoxin levels >or=0.15 IU/mL and 28 of 35 (80%) had oral fluid values >or=0.0015 IU/mL. Among adults lacking a history of tetanus immunization, only 6 of 35 (17.1%) had serum titers >or=0.15 IU/mL and 4 of 35 (11%) had oral fluid titers >or=0.0015 IU/mL in oral fluid. CONCLUSIONS IgG tetanus antitoxin in oral fluid correlates well with levels in serum. OF-ELISA values >or=0.0015 IU/mL constitute protection against tetanus and in subjects >12 months of age imply multiple prior contacts with immunization services. IgG tetanus antitoxin measured by OF-ELISA provides a logistically practical alternative for performing seroprevalence surveys.
Collapse
Affiliation(s)
- Milagritos D Tapia
- Center for Vaccine Development, University of Maryland School of Medicine, Baltimore, Maryland 21201, USA.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Cameron JE, Snowhite IV, Chaturvedi AK, Hagensee ME. Human papillomavirus-specific antibody status in oral fluids modestly reflects serum status in human immunodeficiency virus-positive individuals. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2003; 10:431-8. [PMID: 12738644 PMCID: PMC154956 DOI: 10.1128/cdli.10.3.431-438.2003] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Serological assays are valuable tools for studies of the epidemiology of human papillomaviruses (HPVs). The efficacy of a less invasive oral-fluid assay for detection of HPV antibodies was examined. Matched serum, saliva, and oral mucosal transudate (OMT) specimens collected from 150 human immunodeficiency virus-seropositive patients were tested for immunoglobulin G antibodies against HPV-6 and HPV-11 combined (HPV-6/11) and HPV-16 capsids. Antibodies to HPV were detected in both types of oral specimens. Seroprevalence rates were 55% for HPV-6/11 and 37% for HPV-16, whereas oral prevalence rates were significantly lower (for HPV-6/11 in saliva, 31%, and in OMT, 19%; for HPV-16 in saliva, 19%, and in OMT, 17%). HPV antibody detection in OMT more accurately reflected the presence of antibodies in serum than did HPV antibody detection in saliva. More stringent saliva assay cutpoints yielded stronger associations between oropositivity and seropositivity; less stringent OMT cutpoints yielded stronger associations between oropositivity and seropositivity. Although HPV antibodies were detected in oral fluids, further optimization of the assay is necessary before oral-fluid testing can be implemented as a reliable alternative to serum testing for HPV.
Collapse
Affiliation(s)
- Jennifer E Cameron
- Department of Microbiology, Immunology, and Parasitology, Louisiana State University Health Sciences Center, New Orleans, Louisiana, USA
| | | | | | | |
Collapse
|
8
|
McKie A, Vyse A, Maple C. Novel methods for the detection of microbial antibodies in oral fluid. THE LANCET. INFECTIOUS DISEASES 2002; 2:18-24. [PMID: 11892490 DOI: 10.1016/s1473-3099(01)00169-4] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Compared with blood, oral fluid has several advantages as a sample for antibody detection. It is simple, safe, painless, and cheap to collect. The only drawback is that while the antibody profiles indicate those in blood, they are at lower concentrations. Antibody capture assays are the method of choice for the detection of microbial antibodies in oral fluid, but their relative lack of sensitivity when based on conventional immunoassay techniques has mostly limited their use to epidemiological applications. Immuno-PCR and time-resolved fluorescence offer more sensitive detection systems that could be applied to oral fluid specimens. We review antibody detection in oral fluid and discuss immuno-PCR and time-resolved fluorescence as candidate systems. Both have the potential to broaden the applications of oral fluid testing to clinical diagnostics.
Collapse
Affiliation(s)
- Anne McKie
- Virus Reference Division, Central Public Health Laboratory, 61 Colindale Avenue, London NW9 5HT, UK.
| | | | | |
Collapse
|
9
|
de Oliveira SA, Siqueira MM, Brown DW, Litton P, Camacho LA, Castro ST, Cohen BJ. Diagnosis of rubella infection by detecting specific immunoglobulin M antibodies in saliva samples: a clinic-based study in Niterói, RJ, Brazil. Rev Soc Bras Med Trop 2000; 33:335-9. [PMID: 10936945 DOI: 10.1590/s0037-86822000000400001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study was designed to investigate whether saliva could be a feasible alternative to serum for the diagnosis of recent rubella infection in a clinic setting. Forty-five paired blood and saliva samples collected 1 to 29 days after onset of illness were tested for specific immunoglobulin (Ig) M by antibody-capture radioimmunoassay (MACRIA). Rubella IgM was detected in all serum samples and in 38 (84.4%) saliva specimens. Forty-six serum and saliva samples from other patients with rash diseases were tested by MACRIA for control purposes and two saliva specimens were reactive. The saliva test had specificity of 96%. These results indicate that salivary IgM detection may be a convenient non-invasive alternative to serum for investigation of recent rubella cases, especially for disease surveillance and control programmes.
Collapse
Affiliation(s)
- S A de Oliveira
- Disciplina de Doenças Infecciosas e Parasitárias, Faculdade de Medicina, Universidade Federal Fluminense, Niterói, RJ, Brasil
| | | | | | | | | | | | | |
Collapse
|
10
|
Artimos de Oliveira S, Rodrigues CV, Camacho LA, Miagostovich MP, Araújo ES, Nogueira RM. Diagnosis of dengue infection by detecting specific immunoglobulin M antibodies in saliva samples. J Virol Methods 1999; 77:81-6. [PMID: 10029328 DOI: 10.1016/s0166-0934(98)00139-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
To investigate whether saliva could be used for diagnosis of recent dengue, serum and saliva samples were collected simultaneously from patients with suspected dengue infection. Sera (1:10 dilution) and saliva (undiluted) were tested by using an IgM capture enzyme linked immunosorbent assay (MAC-ELISA) with minor modifications (serum and saliva absorption for 3 h at 37 degrees C). The quality of saliva was evaluated by determining the IgG total concentration (enzyme immunoassay) which ranged from 2.7 to > 50 mg/l. Recent dengue infection was confirmed in 38 cases. Forty-six serum and saliva specimens were collected from these patients 1-30 days after the onset of symptoms. IgM was detected in 65.8% saliva samples. High rate of positivity ( > 80%) was observed for the saliva samples collected > or = 5 days after the onset of the disease. Fifty serum and saliva samples from other 32 patients with rash diseases were also tested and all the specimens were unreactive by MAC-ELISA. These results indicate that saliva may be a convenient non-invasive alternative to serum for diagnosis of recent dengue fever infection, especially for epidemiological studies during outbreaks of the disease.
Collapse
Affiliation(s)
- S Artimos de Oliveira
- Hospital Universitario Antonio Pedro, Disciplina de Doenças Infecciosas e Parasitárias, Faculdade de Medicina, Universidade Federal Fluminense, Rio de Janeiro RJ, Brazil
| | | | | | | | | | | |
Collapse
|
11
|
Oliveira SA, Siqueira MM, Brown DW, Camacho LA, Faillace T, Cohen BJ. Salivary diagnosis of measles for surveillance: a clinic-based study in Niterói, state of Rio de Janeiro, Brazil. Trans R Soc Trop Med Hyg 1998; 92:636-8. [PMID: 10326108 DOI: 10.1016/s0035-9203(98)90793-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
This study was designed to investigate whether saliva could be a feasible alternative to serum for the diagnosis of recent measles infection in a clinic setting. Forty-two paired blood and saliva samples collected 1 to 16 days after onset of illness from 29 patients with clinical measles were tested for specific immunoglobulin (Ig) M by antibody-capture radioimmunoassay. Measles IgM was detected in all serum samples and in 39 (92.9%) saliva specimens. Between 1 and 3 weeks after illness onset, virus-specific IgM was detected in 100% of saliva samples. Measles IgM was also detected in 17 saliva specimens, not paired with blood samples, collected from study patients 5 days to 3 weeks after onset. Our results indicate that salivary IgM detection is a suitable non-invasive method for investigation of notified cases under conditions of routine clinic use.
Collapse
Affiliation(s)
- S A Oliveira
- Hospital Universitário Antonio Pedro, Niterói, RJ, Brazil
| | | | | | | | | | | |
Collapse
|
12
|
Nokes DJ, Enquselassie F, Vyse A, Nigatu W, Cutts FT, Brown DW. An evaluation of oral-fluid collection devices for the determination of rubella antibody status in a rural Ethiopian community. Trans R Soc Trop Med Hyg 1998; 92:679-85. [PMID: 10326122 DOI: 10.1016/s0035-9203(98)90811-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Abstract
We compared 3 different oral-fluid collection devices to assess their suitability for use in community studies of rubella antibody. Of 58 individuals enrolled from 13 households from a southern Ethiopian village, 38 provided a blood sample and oral fluids by the 3 devices: 2 proprietary, Omni-SAL and OraSure, and a third a polystyrene sponge swab (Sponge). The Sponge swab, used like a toothbrush, was most acceptable to survey staff and to participants of all ages, although it proved ill-adapted for fluid extraction. The other devices more often caused participant discomfort or anxiety, particularly in the young. Statistical comparison of rubella-specific immunoglobulin (Ig) G in oral fluid, measured by antibody-capture radioimmunoassay, and in serum, by indirect enzyme-linked immunosorbent assay, showed no clear differences between the devices in oral-fluid performance. Specificity range was 75-100% and sensitivity 73-85%, relative to serum. Specific-antibody levels declined with increasing age, with concomitant decreases in sensitivity, as previously documented. The relationship between specific IgG and total IgG in oral fluid differed by device. Specific IgG levels were highly correlated between paired samples using the Sponge device. We consider the Sponge device to be the most suitable for community survey work, although the extraction method requires improvement. Further work is needed to improve the sensitivity of antibody status determination in adults.
Collapse
Affiliation(s)
- D J Nokes
- Department of Biological Sciences, University of Warwick, Coventry, UK.
| | | | | | | | | | | |
Collapse
|