1
|
Schmidt M, Irsig R, Duca D, Peltz C, Passig J, Zimmermann R. Laser-Pulse-Length Effects in Ultrafast Laser Desorption. Anal Chem 2023; 95:18776-18782. [PMID: 38086534 PMCID: PMC10753527 DOI: 10.1021/acs.analchem.3c03558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 11/02/2023] [Accepted: 11/09/2023] [Indexed: 12/27/2023]
Abstract
Shortening the laser pulse length opens up new opportunities for laser desorption (LD) of molecules, with benefits for mass spectrometry (MS) sampling and ionization. The capability to ablate any material without the need for an absorbing matrix and the decrease of thermal damage and molecular fragmentation has promoted various applications with very different parameters and postionization techniques. However, the key issues of the optimum laser pulse length and intensity to achieve efficient and gentle desorption of molecules for postionization in MS are not resolved, although these parameters determine the costs and complexity of the required laser system. Here, we address this research gap with a systematic study on the effect of the pulse length on the LD of molecules. Keeping all other optical and ionization parameters constant, we directly compared the pulses in the femtosecond, picosecond, and nanosecond range with respect to LD-induced fragmentation and desorption efficiency. To represent real-world applications, we investigated the LD of over-the-counter medicaments naproxen and ibuprofen directly from tablets as well as the LD of retene and ship emission aerosols from a quartz filter. With our study design, we excluded interfering effects on fragmentation and LD efficiency from, for example, collisional cooling or postionization by performing the experiments in vacuum with resonance-enhanced multiphoton ionization as the postionization technique. Regarding LD-induced fragmentation, we already found benefits for the picosecond pulses. However, the efficiency of LD was found to continuously increase with decreasing pulse length, pointing to the application potential of ultrashort pulses in trace analytics. Because many interfering effects beyond the LD pulse length could be excluded in the experiment, our results may be directly transferable to the LD applied in other techniques.
Collapse
Affiliation(s)
- Marco Schmidt
- Joint
Mass Spectrometry Centre, Analytical Chemistry, University of Rostock, 18059 Rostock, Germany
- Comprehensive
Molecular Analytics (CMA) Cooperation Group, Helmholtz Centre Munich, 81379 Munich, Germany
- Department
Life, Light & Matter, University of
Rostock, 18059 Rostock, Germany
| | - Robert Irsig
- Department
Life, Light & Matter, University of
Rostock, 18059 Rostock, Germany
- Photonion
GmbH, 19061 Schwerin, Germany
| | - Dumitru Duca
- Joint
Mass Spectrometry Centre, Analytical Chemistry, University of Rostock, 18059 Rostock, Germany
- Comprehensive
Molecular Analytics (CMA) Cooperation Group, Helmholtz Centre Munich, 81379 Munich, Germany
- Department
Life, Light & Matter, University of
Rostock, 18059 Rostock, Germany
| | - Christian Peltz
- Institute
for Physics, University of Rostock, 18059 Rostock, Germany
| | - Johannes Passig
- Joint
Mass Spectrometry Centre, Analytical Chemistry, University of Rostock, 18059 Rostock, Germany
- Comprehensive
Molecular Analytics (CMA) Cooperation Group, Helmholtz Centre Munich, 81379 Munich, Germany
- Department
Life, Light & Matter, University of
Rostock, 18059 Rostock, Germany
| | - Ralf Zimmermann
- Joint
Mass Spectrometry Centre, Analytical Chemistry, University of Rostock, 18059 Rostock, Germany
- Comprehensive
Molecular Analytics (CMA) Cooperation Group, Helmholtz Centre Munich, 81379 Munich, Germany
- Department
Life, Light & Matter, University of
Rostock, 18059 Rostock, Germany
| |
Collapse
|
2
|
Zagorac T, López Peña HA, Gross JM, Tibbetts KM, Hanley L. Experimental and Theoretical Analysis of Tricyclic Antidepressants by Ultraviolet Picosecond Laser Desorption Post-Ionization Mass Spectrometry. Anal Chem 2023; 95:17541-17549. [PMID: 37983268 DOI: 10.1021/acs.analchem.3c02735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
Imipramine class tricyclic antidepressants have low ionization efficiencies that make them difficult to detect by using secondary ion mass spectrometry. Ultraviolet picosecond laser desorption postionization (ps-LDPI-MS) is examined here for the detection of four tricyclic antidepressants: imipramine, desipramine, amitriptyline, and clomipramine. About 30 ps laser pulses at either 213 nm (5.8 eV) or 355 nm (3.5 eV) are used for desorption of samples under vacuum, 7.9 eV (157 nm) fluorine laser pulses are used for post-ionization, and the ions so formed are detected by time-of-flight mass spectrometry. Detection of imipramine by 213 nm ps-LDPI-MS shows less fragmentation than either 355 nm ps-LDPI-MS or prior results from 800 nm fs-LDPI-MS. Ionization energies of imipramine, desipramine, amitriptyline, and clomipramine are predicted using density functional theory calculations and used to explain the corresponding ps-LDPI-MS data for these four compounds as resulting from single-photon ionization. The experimental observation of low-mass amine-containing fragments with calculated ionization energies below 7.9 eV is attributed mostly to dissociation during laser desorption, followed by single-photon ionization of the neutral fragments rather than the more traditional mechanism of unimolecular dissociation following single-photon ionization of the parent molecule.
Collapse
Affiliation(s)
- Teodora Zagorac
- Department of Chemistry, University of Illinois Chicago, Chicago, Illinois 60607, United States
| | - Hugo Andrés López Peña
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| | - Jason M Gross
- Department of Chemistry, University of Illinois Chicago, Chicago, Illinois 60607, United States
| | - Katharine Moore Tibbetts
- Department of Chemistry, Virginia Commonwealth University, Richmond, Virginia 23284, United States
| | - Luke Hanley
- Department of Chemistry, University of Illinois Chicago, Chicago, Illinois 60607, United States
| |
Collapse
|
3
|
Parise RJ, Dassanayake DR, Levis RJ. Pulse Duration Effects on Solution-Phase Protein Desorption in Laser Electrospray Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:701-709. [PMID: 36947866 DOI: 10.1021/jasms.2c00362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The effect of laser pulse duration on the ablation of aqueous myoglobin is investigated using laser electrospray mass spectrometry (LEMS). Pulse durations of 55 femtoseconds (fs), 56 piscoseconds (ps), and 10 nanoseconds (ns) were used to ablate aqueous myoglobin from stainless-steel and quartz substrates. The integrated signal intensity of myoglobin increases with decreasing pulse duration for both substrates. Laser-induced thermal effects are assessed by the relative amount of solvent adduction and number of phosphate moieties adducted to myoglobin by each laser pulse duration. The mass spectra for 55 fs vaporization shows myoglobin with appreciable solvent and phosphate adduction and baseline elevation. The mass spectra for 10 ns ablation have minimal adduction and limited baseline elevation. Heat-induced conformation changes in myoglobin were used to measure the amount of thermal energy deposited by each laser pulse duration. Ablation using the 55 fs pulse revealed the highest ratio of unfolded to folded myoglobin in comparison to the 56 ps and 10 ns measurements due to increased droplet lifetime and consequent interaction with the acid in the electrospray solvent. Collisional activation and heated capillary temperature were employed to reduce the droplet lifetime and demonstrate that fs ablation preserves approximately 2 times more myoglobin folded conformation in comparison to ps and ns pulses.
Collapse
Affiliation(s)
- Rachel J Parise
- Department of Chemistry, Temple University, 1901 North 13th Street, Philadelphia, Pennsylvania 19122, United States
- Center for Advanced Photonics Research, Temple University, 1901 North 13th Street, Philadelphia, Pennsylvania 19122, United States
| | - Dilini R Dassanayake
- Department of Chemistry, Temple University, 1901 North 13th Street, Philadelphia, Pennsylvania 19122, United States
- Center for Advanced Photonics Research, Temple University, 1901 North 13th Street, Philadelphia, Pennsylvania 19122, United States
| | - Robert J Levis
- Department of Chemistry, Temple University, 1901 North 13th Street, Philadelphia, Pennsylvania 19122, United States
- Center for Advanced Photonics Research, Temple University, 1901 North 13th Street, Philadelphia, Pennsylvania 19122, United States
| |
Collapse
|
4
|
Pulukkody AC, Yung YP, Donnarumma F, Murray KK, Carlson RP, Hanley L. Spatially resolved analysis of Pseudomonas aeruginosa biofilm proteomes measured by laser ablation sample transfer. PLoS One 2021; 16:e0250911. [PMID: 34292966 PMCID: PMC8297752 DOI: 10.1371/journal.pone.0250911] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 06/22/2021] [Indexed: 12/18/2022] Open
Abstract
Heterogeneity in the distribution of nutrients and oxygen gradients during biofilm growth gives rise to changes in phenotype. There has been long term interest in identifying spatial differences during biofilm development including clues that identify chemical heterogeneity. Laser ablation sample transfer (LAST) allows site-specific sampling combined with label free proteomics to distinguish radially and axially resolved proteomes for Pseudomonas aeruginosa biofilms. Specifically, differential protein abundances on oxic vs. anoxic regions of a biofilm were observed by combining LAST with bottom up proteomics. This study reveals a more active metabolism in the anoxic region of the biofilm with respect to the oxic region for this clinical strain of P. aeruginosa, despite this organism being considered an aerobe by nature. Protein abundance data related to cellular acclimations to chemical gradients include identification of glucose catabolizing proteins, high abundance of proteins from arginine and polyamine metabolism, and proteins that could also support virulence and environmental stress mediation in the anoxic region. Finally, the LAST methodology requires only a few mm2 of biofilm area to identify hundreds of proteins.
Collapse
Affiliation(s)
- Aruni Chathurya Pulukkody
- Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois, United States of America
| | - Yeni P. Yung
- Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois, United States of America
| | - Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, United States of America
| | - Kermit K. Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, United States of America
| | - Ross P. Carlson
- Department of Chemical and Biological Engineering, Center for Biofilm Engineering, Montana State University, Bozeman, Montana, United States of America
| | - Luke Hanley
- Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois, United States of America
| |
Collapse
|
5
|
Trimpin S, Marshall DD, Karki S, Madarshahian S, Hoang K, Meher AK, Pophristic M, Richards AL, Lietz CB, Fischer JL, Elia EA, Wang B, Pagnotti VS, Lutomski CA, El-Baba TJ, Lu IC, Wager-Miller J, Mackie K, McEwen CN, Inutan ED. An overview of biological applications and fundamentals of new inlet and vacuum ionization technologies. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35 Suppl 1:e8829. [PMID: 32402102 DOI: 10.1002/rcm.8829] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 05/01/2020] [Accepted: 05/10/2020] [Indexed: 06/11/2023]
Abstract
RATIONALE The developments of new ionization technologies based on processes previously unknown to mass spectrometry (MS) have gained significant momentum. Herein we address the importance of understanding these unique ionization processes, demonstrate the new capabilities currently unmet by other methods, and outline their considerable analytical potential. METHODS The inlet and vacuum ionization methods of solvent-assisted ionization (SAI), matrix-assisted ionization (MAI), and laserspray ionization can be used with commercial and dedicated ion sources producing ions from atmospheric or vacuum conditions for analyses of a variety of materials including drugs, lipids, and proteins introduced from well plates, pipet tips and plate surfaces with and without a laser using solid or solvent matrices. Mass spectrometers from various vendors are employed. RESULTS Results are presented highlighting strengths relative to ionization methods of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization. We demonstrate the utility of multi-ionization platforms encompassing MAI, SAI, and ESI and enabling detection of what otherwise is missed, especially when directly analyzing mixtures. Unmatched robustness is achieved with dedicated vacuum MAI sources with mechanical introduction of the sample to the sub-atmospheric pressure (vacuum MAI). Simplicity and use of a wide array of matrices are attained using a conduit (inlet ionization), preferably heated, with sample introduction from atmospheric pressure. Tissue, whole blood, urine (including mouse, chicken, and human origin), bacteria strains and chemical on-probe reactions are analyzed directly and, especially in the case of vacuum ionization, without concern of carryover or instrument contamination. CONCLUSIONS Examples are provided highlighting the exceptional analytical capabilities associated with the novel ionization processes in MS that reduce operational complexity while increasing speed and robustness, achieving mass spectra with low background for improved sensitivity, suggesting the potential of this simple ionization technology to drive MS into areas currently underserved, such as clinical and medical applications.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | - Darrell D Marshall
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | - Santosh Karki
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | | | - Khoa Hoang
- MS™, LLC, Newark, DE, 19711, USA
- University of the Sciences, Philadelphia, PA, 19104, USA
| | - Anil K Meher
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
| | - Milan Pophristic
- MS™, LLC, Newark, DE, 19711, USA
- University of the Sciences, Philadelphia, PA, 19104, USA
| | - Alicia L Richards
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | | | - Joshua L Fischer
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - Efstathios A Elia
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - Beixi Wang
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | | | - Corinne A Lutomski
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - Tarick J El-Baba
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - I-Chung Lu
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
| | - James Wager-Miller
- Gill Center for Biomolecular Science and Department of Psychological and Brain Sciences, Indiana University, Bloomington, IN, 47405, USA
| | - Ken Mackie
- Gill Center for Biomolecular Science and Department of Psychological and Brain Sciences, Indiana University, Bloomington, IN, 47405, USA
| | - Charles N McEwen
- MS™, LLC, Newark, DE, 19711, USA
- University of the Sciences, Philadelphia, PA, 19104, USA
| | - Ellen D Inutan
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- MS™, LLC, Newark, DE, 19711, USA
- Mindanao State University Iligan Institute of Technology, Iligan City, 9200, Philippines
| |
Collapse
|
6
|
Beneito-Cambra M, Gilbert-López B, Moreno-González D, Bouza M, Franzke J, García-Reyes JF, Molina-Díaz A. Ambient (desorption/ionization) mass spectrometry methods for pesticide testing in food: a review. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:4831-4852. [PMID: 33000770 DOI: 10.1039/d0ay01474e] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Ambient mass spectrometry refers to the family of techniques that allows ions to be generated from condensed phase samples under ambient conditions and then, collected and analysed by mass spectrometry. One of their key advantages relies on their ability to allow the analysis of samples with minimal to no sample workup. This feature maps well to the requirements of food safety testing, in particular, those related to the fast determination of pesticide residues in foods. This review discusses the application of different ambient ionization methods for the qualitative and (semi)quantitative determination of pesticides in foods, with the focus on different specific methods used and their ionization mechanisms. More popular techniques used are those commercially available including desorption electrospray ionization (DESI-MS), direct analysis on real time (DART-MS), paper spray (PS-MS) and low-temperature plasma (LTP-MS). Several applications described with ambient MS have reported limits of quantitation approaching those of reference methods, typically based on LC-MS and generic sample extraction procedures. Some of them have been combined with portable mass spectrometers thus allowing "in situ" analysis. In addition, these techniques have the ability to map surfaces (ambient MS imaging) to unravel the distribution of agrochemicals on crops.
Collapse
Affiliation(s)
- Miriam Beneito-Cambra
- Analytical Chemistry Research Group (FQM-323), Department of Physical and Analytical Chemistry, University of Jaen, 23071 Jaén, Spain.
| | | | | | | | | | | | | |
Collapse
|
7
|
Trimpin S. Novel ionization processes for use in mass spectrometry: 'Squeezing' nonvolatile analyte ions from crystals and droplets. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33 Suppl 3:96-120. [PMID: 30138957 DOI: 10.1002/rcm.8269] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 07/29/2018] [Accepted: 08/15/2018] [Indexed: 05/25/2023]
Abstract
Together with my group and collaborators, I have been fortunate to have had a key role in the discovery of new ionization processes that we developed into new flexible, sensitive, rapid, reliable, and robust ionization technologies and methods for use in mass spectrometry (MS). Our current research is focused on how best to understand, improve, and use these novel ionization processes which convert volatile and nonvolatile compounds from solids or liquids into gas-phase ions for analysis by MS using e.g. mass-selected fragmentation and ion mobility spectrometry to provide reproducible, accurate, and improved mass and drift time resolution. In my view, the apex was the discovery of vacuum matrix-assisted ionization (vMAI) in 2012 on an intermediate pressure matrix-assisted laser desorption/ionization (MALDI) source without the use of a laser, high voltages, or any other added energy. Only exposure of the matrix:analyte to the sub-atmospheric pressure of the mass spectrometer was necessary to initiate ionization. These findings were initially rejected by three different scientific journals, with comments related to 'how can this work?', 'where do the charges come from?', and 'it is not analytically useful'. Meanwhile, we and others have demonstrated analytical utility without a complete understanding of the mechanism. In reality, MALDI and electrospray ionization are widely used in science and their mechanisms are still controversially discussed despite use and optimization of now 30 years. This Perspective covers the applications and mechanistic aspects of the novel ionization processes for use in MS that guided us in instrument developments, and provides our perspective on how they relate to traditional ionization processes.
Collapse
Affiliation(s)
- Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA
- Cardiovascular Research Institute, Wayne State University School of Medicine, Detroit, MI, 48201, USA
- MSTM, LLC, Newark, DE, 19711, USA
| |
Collapse
|
8
|
Perez CJ, Bagga AK, Prova SS, Yousefi Taemeh M, Ifa DR. Review and perspectives on the applications of mass spectrometry imaging under ambient conditions. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33 Suppl 3:27-53. [PMID: 29698560 DOI: 10.1002/rcm.8145] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 04/06/2018] [Accepted: 04/12/2018] [Indexed: 05/18/2023]
Abstract
Ambient mass spectrometry (AMS)-based techniques are performed under ambient conditions in which the ionization and desorption occur in the open environment allowing the direct analysis of molecules with minimal or no sample preparation. A selected group of AMS techniques demonstrate imaging capabilities that can provide information about the localization of molecules on complex sample surfaces such as biological tissues. 2D, 3D, and multimodal imaging have unlocked an array of applications to systematically address complex problems in many areas of research such as drug monitoring, natural products, forensics, and cancer diagnostics. In the present review, we summarize recent advances in the field with respect to the implementation of new ambient ionization techniques and current applications in the last 5 years. In more detail, we mainly focus on imaging applications in topics related to animal whole bodies and tissues, single cells, cancer diagnostics and biomarkers, microbial cultures and co-cultures, plant and natural product metabolomics, and forensic applications. Finally, we discuss new areas of research, future perspectives, and the overall direction that the field may take in the years to come.
Collapse
Affiliation(s)
- Consuelo J Perez
- Centre for Research in Mass Spectrometry, Department of Chemistry, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Aafreen K Bagga
- Centre for Research in Mass Spectrometry, Department of Chemistry, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Shamina S Prova
- Centre for Research in Mass Spectrometry, Department of Chemistry, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Maryam Yousefi Taemeh
- Centre for Research in Mass Spectrometry, Department of Chemistry, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| | - Demian R Ifa
- Centre for Research in Mass Spectrometry, Department of Chemistry, York University, 4700 Keele Street, Toronto, ON, M3J 1P3, Canada
| |
Collapse
|
9
|
Hanley L, Wickramasinghe R, Yung YP. Laser Desorption Combined with Laser Postionization for Mass Spectrometry. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:225-245. [PMID: 30786215 DOI: 10.1146/annurev-anchem-061318-115447] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Lasers with pulse lengths from nanoseconds to femtoseconds and wavelengths from the mid-infrared to extreme ultraviolet (UV) have been used for desorption or ablation in mass spectrometry. Such laser sampling can often benefit from the addition of a second laser for postionization of neutrals. The advantages offered by laser postionization include the ability to forego matrix application, high lateral resolution, decoupling of ionization from desorption, improved analysis of electrically insulating samples, and potential for high sensitivity and depth profiling while minimizing differential detection. A description of postionization by vacuum UV radiation is followed by a consideration of multiphoton, short pulse, and other postionization strategies. The impacts of laser pulse length and wavelength are considered for laser desorption or laser ablation at low pressures. Atomic and molecular analysis via direct laser desorption/ionization using near-infrared ultrashort pulses is described. Finally, the postionization of clusters, the role of gaseous collisions, sampling at ambient pressure, atmospheric pressure photoionization, and the addition of UV postionization to MALDI are considered.
Collapse
Affiliation(s)
- Luke Hanley
- Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois 60607, USA;
| | | | | |
Collapse
|
10
|
Archer JJ, Karki S, Shi F, Sistani H, Levis RJ. Quantification of Protein-Ligand Interactions by Laser Electrospray Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:1484-1492. [PMID: 29654537 DOI: 10.1007/s13361-018-1935-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Revised: 03/01/2018] [Accepted: 03/02/2018] [Indexed: 06/08/2023]
Abstract
Laser electrospray mass spectrometry (LEMS) measurement of the dissociation constant (Kd) for hen egg white lysozyme (HEWL) and N,N',N″-triacetylchitotriose (NAG3) revealed an apparent Kd value of 313.2 ± 25.9 μM for the ligand titration method. Similar measurements for N,N',N″,N″'-tetraacetylchitotetraose (NAG4) revealed an apparent Kd of 249.3 ± 13.6 μM. An electrospray ionization mass spectrometry (ESI-MS) experiment determined a Kd value of 9.8 ± 0.6 μM. In a second LEMS approach, a calibrated measurement was used to determine a Kd value of 6.8 ± 1.5 μM for NAG3. The capture efficiency of LEMS was measured to be 3.6 ± 1.8% and is defined as the fraction of LEMS sample detected after merging with the ESI plume. When the dilution is factored into the ligand titration measurement, the adjusted Kd value was 11.3 μM for NAG3 and 9.0 μM for NAG4. The calibration method for measuring Kd developed in this study can be applied to solutions containing unknown analyte concentrations. Graphical Abstract.
Collapse
Affiliation(s)
- Jieutonne J Archer
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, Philadelphia, PA, 19122, USA
| | - Santosh Karki
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, Philadelphia, PA, 19122, USA
| | - Fengjian Shi
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, Philadelphia, PA, 19122, USA
| | - Habiballah Sistani
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, Philadelphia, PA, 19122, USA
| | - Robert J Levis
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, Philadelphia, PA, 19122, USA.
| |
Collapse
|
11
|
Lu Y, Pieterse CL, Robertson WD, Miller RJD. Soft Picosecond Infrared Laser Extraction of Highly Charged Proteins and Peptides from Bulk Liquid Water for Mass Spectrometry. Anal Chem 2018. [PMID: 29522677 DOI: 10.1021/acs.analchem.7b04306] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We report the soft laser extraction and production of highly charged peptide and protein ions for mass spectrometry directly from bulk liquid water at atmospheric pressure and room temperature, using picosecond infrared laser ablation. Stable ion signal from singly charged small molecules, as well as highly charged biomolecular ions, from aqueous solutions at low laser pulse fluence (∼0.3 J cm-2) is demonstrated. Sampling via single picosecond laser pulses is shown to extract less than 27 pL of volume from the sample, producing highly charged peptide and protein ions for mass spectrometry detection. The ablation and ion generation is demonstrated to be soft in nature, producing natively folded proteins ions under sample conditions described for native mass spectrometry. The method provides laser-based sampling flexibility, precision and control with highly charged ion production directly from water at low and near neutral pH. This approach does not require an additional ionization device or high voltage applied directly to the sample.
Collapse
Affiliation(s)
- Yinfei Lu
- Max Planck Institute for the Structure and Dynamics of Matter , Luruper Chaussee 149 , Hamburg 22761 , Germany
| | - Cornelius L Pieterse
- Max Planck Institute for the Structure and Dynamics of Matter , Luruper Chaussee 149 , Hamburg 22761 , Germany
| | - Wesley D Robertson
- Max Planck Institute for the Structure and Dynamics of Matter , Luruper Chaussee 149 , Hamburg 22761 , Germany
| | - R J Dwayne Miller
- Max Planck Institute for the Structure and Dynamics of Matter , Luruper Chaussee 149 , Hamburg 22761 , Germany
| |
Collapse
|
12
|
Yung YP, Wickramasinghe R, Vaikkinen A, Kauppila TJ, Veryovkin IV, Hanley L. Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry. Anal Chem 2017. [PMID: 28632988 PMCID: PMC5518277 DOI: 10.1021/acs.analchem.7b01745] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
![]()
A hand-held diode
laser is implemented for solid sampling in portable
ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave
battery-powered surgical laser diode is employed for portable laser
diode thermal desorption (LDTD) at 940 nm and compared with nanosecond
pulsed laser ablation at 2940 nm. Postionization is achieved in both
cases using atmospheric pressure photoionization (APPI). The laser
ablation atmospheric pressure photoionization (LAAPPI) and LDTD-APPI
mass spectra of sage leaves (Salvia officinalis) using a field-deployable quadrupole ion trap MS display many similar
ion peaks, as do the mass spectra of membrane grown biofilms of Pseudomonas aeruginosa. These results indicate that
LDTD-APPI method should be useful for in-field sampling of plant and
microbial communities, for example, by portable ambient MS. The feasibility
of many portable MS applications is facilitated by the availability
of relatively low cost, portable, battery-powered diode lasers. LDTD
could also be coupled with plasma- or electrospray-based ionization
for the analysis of a variety of solid samples.
Collapse
Affiliation(s)
- Yeni P Yung
- Department of Chemistry, University of Illinois at Chicago , Chicago, Illinois 60607, United States
| | - Raveendra Wickramasinghe
- Department of Chemistry, University of Illinois at Chicago , Chicago, Illinois 60607, United States
| | - Anu Vaikkinen
- Division of Pharmaceutical Chemistry and Technology, University of Helsinki , Helsinki, Finland
| | - Tiina J Kauppila
- Division of Pharmaceutical Chemistry and Technology, University of Helsinki , Helsinki, Finland
| | - Igor V Veryovkin
- Department of Chemistry, University of Illinois at Chicago , Chicago, Illinois 60607, United States
| | - Luke Hanley
- Department of Chemistry, University of Illinois at Chicago , Chicago, Illinois 60607, United States
| |
Collapse
|
13
|
Meher AK, Chen YC. Electrospray Modifications for Advancing Mass Spectrometric Analysis. ACTA ACUST UNITED AC 2017; 6:S0057. [PMID: 28573082 DOI: 10.5702/massspectrometry.s0057] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 12/30/2016] [Indexed: 11/23/2022]
Abstract
Generation of analyte ions in gas phase is a primary requirement for mass spectrometric analysis. One of the ionization techniques that can be used to generate gas phase ions is electrospray ionization (ESI). ESI is a soft ionization method that can be used to analyze analytes ranging from small organics to large biomolecules. Numerous ionization techniques derived from ESI have been reported in the past two decades. These ion sources are aimed to achieve simplicity and ease of operation. Many of these ionization methods allow the flexibility for elimination or minimization of sample preparation steps prior to mass spectrometric analysis. Such ion sources have opened up new possibilities for taking scientific challenges, which might be limited by the conventional ESI technique. Thus, the number of ESI variants continues to increase. This review provides an overview of ionization techniques based on the use of electrospray reported in recent years. Also, a brief discussion on the instrumentation, underlying processes, and selected applications is also presented.
Collapse
Affiliation(s)
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University
| |
Collapse
|
14
|
Moreno-García P, Grimaudo V, Riedo A, Tulej M, Wurz P, Broekmann P. Towards matrix-free femtosecond-laser desorption mass spectrometry for in situ space research. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:1031-1036. [PMID: 27003040 DOI: 10.1002/rcm.7533] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 02/03/2016] [Accepted: 02/03/2016] [Indexed: 06/05/2023]
Abstract
RATIONALE There is an increasing interest in the quest for low molecular weight biomarkers that can be studied on extra-terrestrial objects by direct laser desorption mass spectrometry (LD-MS). Although molecular structure investigations have recently been carried out by direct LD-MS approaches, there is still a lack of suitable instruments for implementation on a spacecraft due to weight, size and power consumption demands. In this contribution we demonstrate the feasibility of LD-MS structural analysis of molecular species by a miniature laser desorption-ionization mass spectrometer (instrument name LMS) originally designed for in situ elemental and isotope analysis of solids in space research. METHODS Direct LD-MS studies with molecular resolution were carried out by means of a Laser Ablation/Ionization Mass Spectrometry (LIMS) technique. Two polymer samples served as model systems: neutral polyethylene glycol (PEG) and cationic polymerizates of imidazole and epichlorohydrin (IMEP). Optimal conditions for molecular fragmentation could be identified for both polymers by tuning the laser energy and the instrument-sample distance. RESULTS PEG and IMEP polymers show sufficient stability over a relatively wide laser energy range. Under mild LD conditions only moderate fragmentation of the polymers takes place so that valuable structural characterization based on fragment ions can be achieved. As the applied laser pulse energy rises, the abundance of fragment ions increases, reaches a plateau and subsequently drops down due to more severe fragmentation and atomization of the polymers. At this final stage, usually referred to as laser ablation, only elemental/isotope analysis can be achieved. CONCLUSIONS Our investigations demonstrate the versatility of the LMS instrument that can be tuned to favourable laser desorption conditions that successfully meet molecule-specific requirements and deliver abundant fragment ion signals with detailed structural information. Overall, the results show promise for use in similar studies on planetary surfaces beyond Earth where no or minimal sample preparation is essential.
Collapse
Affiliation(s)
- Pavel Moreno-García
- Department of Chemistry and Biochemistry, Interfacial Electrochemistry Group, University of Bern, Freiestrasse 3, 3012, Bern, Switzerland
| | - Valentine Grimaudo
- Department of Chemistry and Biochemistry, Interfacial Electrochemistry Group, University of Bern, Freiestrasse 3, 3012, Bern, Switzerland
| | - Andreas Riedo
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
| | - Marek Tulej
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
| | - Peter Wurz
- Physics Institute, Space Research and Planetary Sciences, University of Bern, Sidlerstrasse 5, 3012, Bern, Switzerland
| | - Peter Broekmann
- Department of Chemistry and Biochemistry, Interfacial Electrochemistry Group, University of Bern, Freiestrasse 3, 3012, Bern, Switzerland
| |
Collapse
|
15
|
Shi F, Flanigan PM, Archer JJ, Levis RJ. Ambient Molecular Analysis of Biological Tissue Using Low-Energy, Femtosecond Laser Vaporization and Nanospray Postionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:542-551. [PMID: 26667178 DOI: 10.1007/s13361-015-1302-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2015] [Revised: 10/22/2015] [Accepted: 10/27/2015] [Indexed: 06/05/2023]
Abstract
Direct analysis of plant and animal tissue samples by laser electrospray mass spectrometry (LEMS) was investigated using low-energy, femtosecond duration laser vaporization at wavelengths of 800 and 1042 nm followed by nanospray postionization. Low-energy (<50 μJ), fiber-based 1042 nm LEMS (F-LEMS) allowed interrogation of the molecular species in fresh flower petal and leaf samples using 435 fs, 10 Hz bursts of 20 pulses from a Ytterbium-doped fiber laser and revealed comparable results to high energy (75-1120 μJ), 45 fs, 800 nm Ti:Sapphire-based LEMS (Ti:Sapphire-LEMS) measurements. Anthocyanins, sugars, and other metabolites were successfully detected and revealed the anticipated metabolite profile for the petal and leaf samples. Phospholipids, especially phosphatidylcholine, were identified from a fresh mouse brain section sample using Ti:Sapphire-LEMS without the application of matrix. These lipid features were suppressed in both the fiber-based and Ti:Sapphire-based LEMS measurements when the brain sample was prepared using the optimal cutting temperature compounds that are commonly used in animal tissue cryosections.
Collapse
Affiliation(s)
- Fengjian Shi
- Department of Chemistry, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA
- Center for Advanced Photonics Research, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA
| | - Paul M Flanigan
- Department of Chemistry, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA
- Center for Advanced Photonics Research, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA
- Signature Science, LLC., 2819 Fire Rd, Egg Harbor Township, NJ, 08234, USA
| | - Jieutonne J Archer
- Department of Chemistry, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA
- Center for Advanced Photonics Research, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA
| | - Robert J Levis
- Department of Chemistry, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA.
- Center for Advanced Photonics Research, Temple University, 1901 N. 13th St., Philadelphia, PA, 19122, USA.
| |
Collapse
|
16
|
Shi F, Archer JJ, Levis RJ. Nonresonant, femtosecond laser vaporization and electrospray post-ionization mass spectrometry as a tool for biological tissue imaging. Methods 2016; 104:79-85. [PMID: 26931651 DOI: 10.1016/j.ymeth.2016.02.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2015] [Revised: 02/19/2016] [Accepted: 02/24/2016] [Indexed: 12/30/2022] Open
Abstract
An ambient mass spectrometry imaging (MSI) source is demonstrated with both high spatial and mass resolution that enables measurement of the compositional heterogeneity within a biological tissue sample. The source is based on nonresonant, femtosecond laser electrospray mass spectrometry (LEMS) coupled to a quadrupole time-of-flight (QTOF) mass analyzer. No matrix deposition and minimal sample preparation is necessary for the source. The laser, translation stage, and mass spectrometer are synchronized and controlled using a customized user interface. Single or multiple laser shots may be applied to each pixel. A scanning rate of 2.0s per pixel is achieved. Measurement of a patterned ink film indicates the potential of LEMS for ambient imaging with a lateral resolution of ∼60μm. Metabolites including sugar, anthocyanins and other small metabolites were successfully mapped from plant samples without oversampling using a spot size of 60×70μm(2). Molecular identification of the detected analytes from the tissue was enabled by accurate mass measurement in conjunction with tandem mass spectrometry. Statistical analysis, non-negative matrix factorization and principle component analysis, were applied to the imaging data to extract regions with distinct and/or correlated spectral profiles.
Collapse
Affiliation(s)
- Fengjian Shi
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, 1901 N. 13th St., Philadelphia, PA 19122, United States
| | - Jieutonne J Archer
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, 1901 N. 13th St., Philadelphia, PA 19122, United States
| | - Robert J Levis
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, 1901 N. 13th St., Philadelphia, PA 19122, United States.
| |
Collapse
|
17
|
Seneviratne CA, Ghorai S, Murray KK. Laser desorption sample transfer for gas chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:89-94. [PMID: 26661974 DOI: 10.1002/rcm.7419] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Accepted: 10/06/2015] [Indexed: 06/05/2023]
Abstract
RATIONALE Ambient mass spectrometry can detect small molecules directly, but complex mixtures can be a challenge. We have developed a method that incorporates small molecule separation based on laser desorption with capture on a solid-phase microextraction (SPME) fiber for injection into a gas chromatography/mass spectrometry (GC/MS) system. METHODS Samples on a metal target were desorbed by a 3 µm mid-infrared laser focused to a 250 µm spot and 1.2 mJ pulse energy. The desorbed material was aspirated into a metal tube suspended 1 mm above the laser spot and captured on a SPME fiber. The collected material was injected into a GC/MS instrument for analysis. RESULTS We have developed a versatile approach for ambient laser desorption sampling onto SPME for GC/MS analysis. The performance of the laser desorption SPME capture GC/MS system was demonstrated for small molecule standards, a mixture of nitroaromatic explosives, and collected cigarette smoke. CONCLUSIONS The utility of ambient laser desorption sampling onto SPME for GC/MS was demonstrated. The performance of the method was evaluated by preparing calibration standards of caffeine over a range from 200 to 1000 ng. Laser desorption ambient sampling of complex mixtures was accomplished using SPME GC/MS.
Collapse
Affiliation(s)
| | - Suman Ghorai
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| |
Collapse
|
18
|
Trimpin S. "Magic" Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:4-21. [PMID: 26486514 PMCID: PMC4686549 DOI: 10.1007/s13361-015-1253-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2015] [Revised: 08/05/2015] [Accepted: 08/12/2015] [Indexed: 05/11/2023]
Abstract
The systematic study of the temperature and pressure dependence of matrix-assisted ionization (MAI) led us to the discovery of the seemingly impossible, initially explained by some reviewers as either sleight of hand or the misinterpretation by an overzealous young scientist of results reported many years before and having little utility. The “magic” that we were attempting to report was that with matrix assistance, molecules, at least as large as bovine serum albumin (66 kDa), are lifted into the gas phase as multiply charged ions simply by exposure of the matrix:analyte sample to the vacuum of a mass spectrometer. Applied heat, a laser, or voltages are not necessary to achieve charge states and ion abundances only previously observed with electrospray ionization (ESI). The fundamentals of how solid phase volatile or nonvolatile compounds are converted to gas-phase ions without added energy currently involves speculation providing a great opportunity to rethink mechanistic understanding of ionization processes used in mass spectrometry. Improved understanding of the mechanism(s) of these processes and their connection to ESI and matrix-assisted laser desorption/ionization may provide opportunities to further develop new ionization strategies for traditional and yet unforeseen applications of mass spectrometry. This Critical Insights article covers developments leading to the discovery of a seemingly magic ionization process that is simple to use, fast, sensitive, robust, and can be directly applied to surface characterization using portable or high performance mass spectrometers.
Collapse
Affiliation(s)
- Sarah Trimpin
- />Department of Chemistry, Wayne State University, Detroit, MI 48202 USA
- />Cardiovascular Research Institute, Wayne State University School of Medicine, Detroit, MI 48201 USA
- />MSTM, LLC, Newark, DE 19711 USA
| |
Collapse
|
19
|
Karki S, Flanigan PM, Perez JJ, Archer JJ, Levis RJ. Increasing protein charge state when using laser electrospray mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:706-715. [PMID: 25753972 DOI: 10.1007/s13361-015-1084-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Revised: 01/20/2015] [Accepted: 01/22/2015] [Indexed: 06/04/2023]
Abstract
Femtosecond (fs) laser vaporization is used to transfer cytochrome c, myoglobin, lysozyme, and ubiquitin from the condensed phase into an electrospray (ES) plume consisting of a mixture of a supercharging reagent, m-nitrobenzyl alcohol (m-NBA), and trifluoroacetic acid (TFA), acetic acid (AA), or formic acid (FA). Interaction of acid-sensitive proteins like cytochrome c and myoglobin with the highly charged ES droplets resulted in a shift to higher charge states in comparison with acid-stable proteins like lysozyme and ubiquitin. Laser electrospray mass spectrometry (LEMS) measurements showed an increase in both the average charge states (Zavg) and the charge state with maximum intensity (Zmode) for acid-sensitive proteins compared with conventional electrospray ionization mass spectrometry (ESI-MS) under equivalent solvent conditions. A marked increase in ion abundance of higher charge states was observed for LEMS in comparison with conventional electrospray for cytochrome c (ranging from 19+ to 21+ versus 13+ to 16+) and myoglobin (ranging from 19+ to 26+ versus 18+ to 21+) using an ES solution containing m-NBA and TFA. LEMS measurements as a function of electrospray flow rate yielded increasing charge states with decreasing flow rates for cytochrome c and myoglobin.
Collapse
Affiliation(s)
- Santosh Karki
- Department of Chemistry and Center for Advanced Photonics Research, Temple University, Philadelphia, PA, 19122, USA
| | | | | | | | | |
Collapse
|