1
|
Ozcan BB, Wanniarachchi H, Mason RP, Dogan BE. Current status of optoacoustic breast imaging and future trends in clinical application: is it ready for prime time? Eur Radiol 2024:10.1007/s00330-024-10600-2. [PMID: 38308678 DOI: 10.1007/s00330-024-10600-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 12/07/2023] [Accepted: 12/26/2023] [Indexed: 02/05/2024]
Abstract
Optoacoustic imaging (OAI) is an emerging field with increasing applications in patients and exploratory clinical trials for breast cancer. Optoacoustic imaging (or photoacoustic imaging) employs non-ionizing, laser light to create thermoelastic expansion in tissues and detect the resulting ultrasonic emission. By combining high optical contrast capabilities with the high spatial resolution and anatomic detail of grayscale ultrasound, OAI offers unique opportunities for visualizing biological function of tissues in vivo. Over the past decade, human breast applications of OAI, including benign/malignant mass differentiation, distinguishing cancer molecular subtype, and predicting metastatic potential, have significantly increased. We discuss the current state of optoacoustic breast imaging, as well as future opportunities and clinical application trends. CLINICAL RELEVANCE STATEMENT: Optoacoustic imaging is a novel breast imaging technique that enables the assessment of breast cancer lesions and tumor biology without the risk of ionizing radiation exposure, intravenous contrast, or radionuclide injection. KEY POINTS: • Optoacoustic imaging (OAI) is a safe, non-invasive imaging technique with thriving research and high potential clinical impact. • OAI has been considered a complementary tool to current standard breast imaging techniques. • OAI combines parametric maps of molecules that absorb light and scatter acoustic waves (like hemoglobin, melanin, lipids, and water) with anatomical images, facilitating scalable and real-time molecular evaluation of tissues.
Collapse
Affiliation(s)
- B Bersu Ozcan
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard MC 8896, Dallas, TX, 75390-8896, USA.
| | - Hashini Wanniarachchi
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard MC 8896, Dallas, TX, 75390-8896, USA
| | - Ralph P Mason
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard MC 8896, Dallas, TX, 75390-8896, USA
| | - Basak E Dogan
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard MC 8896, Dallas, TX, 75390-8896, USA
| |
Collapse
|
2
|
Rai N, Kailashiya V, Gautam V. Exploring the Protective Effect against 7,12-Dimethylbenz[a]anthracene-Induced Breast Tumors of Palmitoylethanolamide. ACS Pharmacol Transl Sci 2024; 7:97-109. [PMID: 38230286 PMCID: PMC10789129 DOI: 10.1021/acsptsci.3c00188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 10/26/2023] [Accepted: 10/31/2023] [Indexed: 01/18/2024]
Abstract
Breast cancer remains a global health burden, and the need for effective therapies is of chief importance. The current study explored the in vivo chemoprotective activity of palmitoylethanolamide (PEA) against 7,12-dimethylbenz[a]anthracene (DMBA)-induced breast tumor in rats. Results of noninvasive photoacoustic imaging showed real-time progression in the tumor area and volume in DMBA-induced rats, while there was a reduction in tumor area and volume in PEA-treated tumor-bearing rats. The increase in the average oxygen saturation (sO2 %) and decrease in the average total hemoglobin (HbT %) indicated the PEA-mediated attenuation of hypoxia-induced neovascularization in DMBA-induced rats. Histopathological investigations confirmed the efficacy of PEA in mitigating breast carcinoma, hepatotoxicity and nephrotoxicity driven by DMBA. Moreover, PEA-mediated alterations in the metabolic activity of the tumor microenvironment were evidenced by decreased glucose and lactate dehydrogenase enzyme level in the blood plasma and mammary tissue. PEA also maintained the redox balance by inhibiting nitric oxide level, reducing malondialdehyde (a product of lipid peroxidation), and increasing the level of antioxidant enzyme reduced glutathione. PEA altered the expression of apoptosis-related genes (BAX, P53,BCL-XL, CASPASE-8, and CASPASE-9) and induced the activity of Caspase-3 protein in the mammary tissue of tumor-bearing rats, indicating its apoptosis inducing ability. Taken together, the findings of this study suggest that PEA may have a protective effect against DMBA-induced breast tumors.
Collapse
Affiliation(s)
- Nilesh Rai
- Centre
of Experimental Medicine and Surgery, Institute of Medical Sciences, Banaras Hindu University, Varanasi 221005, India
| | - Vikas Kailashiya
- Department
of Pathology, Institute of Medical Sciences, Banaras Hindu University, Varanasi 221005, India
| | - Vibhav Gautam
- Centre
of Experimental Medicine and Surgery, Institute of Medical Sciences, Banaras Hindu University, Varanasi 221005, India
| |
Collapse
|
3
|
Sridharan B, Lim HG. Advances in photoacoustic imaging aided by nano contrast agents: special focus on role of lymphatic system imaging for cancer theranostics. J Nanobiotechnology 2023; 21:437. [PMID: 37986071 PMCID: PMC10662568 DOI: 10.1186/s12951-023-02192-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 11/03/2023] [Indexed: 11/22/2023] Open
Abstract
Photoacoustic imaging (PAI) is a successful clinical imaging platform for management of cancer and other health conditions that has seen significant progress in the past decade. However, clinical translation of PAI based methods are still under scrutiny as the imaging quality and clinical information derived from PA images are not on par with other imaging methods. Hence, to improve PAI, exogenous contrast agents, in the form of nanomaterials, are being used to achieve better image with less side effects, lower accumulation, and improved target specificity. Nanomedicine has become inevitable in cancer management, as it contributes at every stage from diagnosis to therapy, surgery, and even in the postoperative care and surveillance for recurrence. Nanocontrast agents for PAI have been developed and are being explored for early and improved cancer diagnosis. The systemic stability and target specificity of the nanomaterials to render its theranostic property depends on various influencing factors such as the administration route and physico-chemical responsiveness. The recent focus in PAI is on targeting the lymphatic system and nodes for cancer diagnosis, as they play a vital role in cancer progression and metastasis. This review aims to discuss the clinical advancements of PAI using nanoparticles as exogenous contrast agents for cancer theranostics with emphasis on PAI of lymphatic system for diagnosis, cancer progression, metastasis, PAI guided tumor resection, and finally PAI guided drug delivery.
Collapse
Affiliation(s)
- Badrinathan Sridharan
- Department of Biomedical Engineering, Pukyong National University, Busan, 48513, Republic of Korea
| | - Hae Gyun Lim
- Department of Biomedical Engineering, Pukyong National University, Busan, 48513, Republic of Korea.
| |
Collapse
|
4
|
Gao S, Jiang Y, Li M, Wang Y, Shen Y, Flegal MC, Nephew BC, Fischer GS, Liu Y, Fichera L, Zhang HK. Laparoscopic Photoacoustic Imaging System Based on Side-Illumination Diffusing Fibers. IEEE Trans Biomed Eng 2023; 70:3187-3196. [PMID: 37224375 PMCID: PMC10592404 DOI: 10.1109/tbme.2023.3279772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVE To develop a flexible miniaturized photoacoustic (PA) imaging probe for detecting anatomical structures during laparoscopic surgery. The proposed probe aimed to facilitate intraoperative detection of blood vessels and nerve bundles embedded in tissue not directly visible to the operating physician to preserve these delicate and vital structures. METHODS We modified a commercially available ultrasound laparoscopic probe by incorporating custom-fabricated side-illumination diffusing fibers that illuminate the probe's field of view. The probe geometry, including the position and orientation of the fibers and the emission angle, was determined using computational models of light propagation in the simulation and subsequently validated through experimental studies. RESULTS In wire phantom studies within an optical scattering medium, the probe achieved an imaging resolution of 0.43 ±0.09 mm and a signal-to-noise ratio of 31.2±1.84 dB. We also conducted an ex vivo study using a rat model, demonstrating the successful detection of blood vessels and nerves. CONCLUSION Our results indicate the viability of a side-illumination diffusing fiber PA imaging system for guidance during laparoscopic surgery. SIGNIFICANCE The potential clinical translation of this technology could enhance the preservation of critical vascular structures and nerves, thereby minimizing post-operative complications.
Collapse
|
5
|
Gao S, Wang Y, Ma X, Zhou H, Jiang Y, Yang K, Lu L, Wang S, Nephew BC, Fichera L, Fischer GS, Zhang HK. Intraoperative laparoscopic photoacoustic image guidance system in the da Vinci surgical system. BIOMEDICAL OPTICS EXPRESS 2023; 14:4914-4928. [PMID: 37791285 PMCID: PMC10545189 DOI: 10.1364/boe.498052] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/23/2023] [Accepted: 07/31/2023] [Indexed: 10/05/2023]
Abstract
This paper describes a framework allowing intraoperative photoacoustic (PA) imaging integrated into minimally invasive surgical systems. PA is an emerging imaging modality that combines the high penetration of ultrasound (US) imaging with high optical contrast. With PA imaging, a surgical robot can provide intraoperative neurovascular guidance to the operating physician, alerting them of the presence of vital substrate anatomy invisible to the naked eye, preventing complications such as hemorrhage and paralysis. Our proposed framework is designed to work with the da Vinci surgical system: real-time PA images produced by the framework are superimposed on the endoscopic video feed with an augmented reality overlay, thus enabling intuitive three-dimensional localization of critical anatomy. To evaluate the accuracy of the proposed framework, we first conducted experimental studies in a phantom with known geometry, which revealed a volumetric reconstruction error of 1.20 ± 0.71 mm. We also conducted an ex vivo study by embedding blood-filled tubes into chicken breast, demonstrating the successful real-time PA-augmented vessel visualization onto the endoscopic view. These results suggest that the proposed framework could provide anatomical and functional feedback to surgeons and it has the potential to be incorporated into robot-assisted minimally invasive surgical procedures.
Collapse
Affiliation(s)
- Shang Gao
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Yang Wang
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Xihan Ma
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Haoying Zhou
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Yiwei Jiang
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Kehan Yang
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Liang Lu
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Department of Computer Science, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Shiyue Wang
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Department of Computer Science, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Benjamin C. Nephew
- Department of Biology & Biotechnology, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Neuroscience Program, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Loris Fichera
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Gregory S. Fischer
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Department of Mechanical & Materials Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Department of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Department of Electrical & Computer Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| | - Haichong K. Zhang
- Department of Robotics Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Department of Computer Science, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
- Department of Biomedical Engineering, Worcester Polytechnic Institute, 100 Institute Rd, Worcester, MA 01609, USA
| |
Collapse
|
6
|
Zhou M, Zhang L, Zeng J, Lan Y, He F, Gao W, Li J, Wang Q, Guo W, Yuan Z, Zhang J. Visualizing the early-stage testicular torsion by dual-modal photoacoustic and ultrasound imaging. PHOTOACOUSTICS 2023; 31:100523. [PMID: 37362871 PMCID: PMC10285283 DOI: 10.1016/j.pacs.2023.100523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/27/2023] [Accepted: 06/08/2023] [Indexed: 06/28/2023]
Abstract
Delayed treatment of testicular torsion (TT) can lead to permanent loss of reproductive capacity. Photoacoustic imaging (PAI) and ultrasound imaging (USI) was tested for detecting TT at early stage in mice based on PAI-obtained oxygen saturation (sO2), and USI-collected color pixel density (CPD), peak systolic velocity (PSV) and resistance index (RI). For complete TT, both CPD (9.08 % ± 3.084 to almost zero) and sO2 data (70.09 % ± 1.656-59.84 % ± 1.427) showed an significant change 2 h post-torsion. For incomplete TT, sO2 data exhibited a strong time relationship (Mean values: 6 h, 64.83 % ± 1.898; 12 h, 60.67 % ± 3.555; 24 h, 57.85 % ± 3.575; P < 0.05). However, USI-collected CPD, PSV or IR data from the same TT models showed no significant difference. This study indicated that USI and PAI could identify complete TT. Meanwhile, PAI has shown great potential in the diagnosis of incomplete TT within 24 h based on time-related sO2 map.
Collapse
Affiliation(s)
- Mengyu Zhou
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
- Guangdong Engine Research Center of Urinary Continence and Reproductive Medicine, The Sixth Affiliated Hospital of Guangzhou Medical University, Qingyuan, Guangdong, China
| | - Luting Zhang
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Jianwen Zeng
- Guangdong Engine Research Center of Urinary Continence and Reproductive Medicine, The Sixth Affiliated Hospital of Guangzhou Medical University, Qingyuan, Guangdong, China
| | - Yintao Lan
- Bioland Laboratory (Guangzhou Regenerative Medicine and Health—Guangdong Laboratory), Guangzhou, Guangdong, China
| | - Fengbing He
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Weijian Gao
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Jinghang Li
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Qian Wang
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Weisheng Guo
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Zhen Yuan
- Faculty of Health Sciences, University of Macao, Macao, China
| | - Jian Zhang
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China
- Guangdong Engine Research Center of Urinary Continence and Reproductive Medicine, The Sixth Affiliated Hospital of Guangzhou Medical University, Qingyuan, Guangdong, China
| |
Collapse
|
7
|
Gu Y, Sun Y, Wang X, Li H, Qiu J, Lu W. Application of photoacoustic computed tomography in biomedical imaging: A literature review. Bioeng Transl Med 2023; 8:e10419. [PMID: 36925681 PMCID: PMC10013779 DOI: 10.1002/btm2.10419] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 09/11/2022] [Accepted: 09/18/2022] [Indexed: 11/06/2022] Open
Abstract
Photoacoustic computed tomography (PACT) is a hybrid imaging modality that combines optical excitation and acoustic detection techniques. It obtains high-resolution deep-tissue images based on the deep penetration of light, the anisotropy of light absorption in objects, and the photoacoustic effect. Hence, PACT shows great potential in biomedical sample imaging. Recently, due to its advantages of high sensitivity to optical absorption and wide scalability of spatial resolution with the desired imaging depth, PACT has received increasing attention in preclinical and clinical practice. To date, there has been a proliferation of PACT systems designed for specific biomedical imaging applications, from small animals to human organs, from ex vivo to in vivo real-time imaging, and from simple structural imaging to functional and molecular imaging with external contrast agents. Therefore, it is of great importance to summarize the previous applications of PACT systems in biomedical imaging and clinical practice. In this review, we searched for studies related to PACT imaging of biomedical tissues and samples over the past two decades; divided the studies into two categories, PACT imaging of preclinical animals and PACT imaging of human organs and body parts; and discussed the significance of the studies. Finally, we pointed out the future directions of PACT in biomedical applications. With the development of exogenous contrast agents and advances of imaging technique, in the future, PACT will enable biomedical imaging from organs to whole bodies, from superficial vasculature to internal organs, from anatomy to functions, and will play an increasingly important role in biomedical research and clinical practice.
Collapse
Affiliation(s)
- Yanru Gu
- Department of Radiology The Second Affiliated Hospital of Shandong First Medical University Taian China.,Department of Radiology Shandong First Medical University and Shandong Academy of Medical Sciences Taian China
| | - Yuanyuan Sun
- Department of Radiology Shandong First Medical University and Shandong Academy of Medical Sciences Taian China
| | - Xiao Wang
- College of Ocean Science and Engineering Shandong University of Science and Technology Qingdao China
| | - Hongyu Li
- College of Ocean Science and Engineering Shandong University of Science and Technology Qingdao China
| | - Jianfeng Qiu
- Department of Radiology Shandong First Medical University and Shandong Academy of Medical Sciences Taian China
| | - Weizhao Lu
- Department of Radiology The Second Affiliated Hospital of Shandong First Medical University Taian China.,Department of Radiology Shandong First Medical University and Shandong Academy of Medical Sciences Taian China
| |
Collapse
|
8
|
Bai JW, Qiu SQ, Zhang GJ. Molecular and functional imaging in cancer-targeted therapy: current applications and future directions. Signal Transduct Target Ther 2023; 8:89. [PMID: 36849435 PMCID: PMC9971190 DOI: 10.1038/s41392-023-01366-y] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 01/19/2023] [Accepted: 02/14/2023] [Indexed: 03/01/2023] Open
Abstract
Targeted anticancer drugs block cancer cell growth by interfering with specific signaling pathways vital to carcinogenesis and tumor growth rather than harming all rapidly dividing cells as in cytotoxic chemotherapy. The Response Evaluation Criteria in Solid Tumor (RECIST) system has been used to assess tumor response to therapy via changes in the size of target lesions as measured by calipers, conventional anatomically based imaging modalities such as computed tomography (CT), and magnetic resonance imaging (MRI), and other imaging methods. However, RECIST is sometimes inaccurate in assessing the efficacy of targeted therapy drugs because of the poor correlation between tumor size and treatment-induced tumor necrosis or shrinkage. This approach might also result in delayed identification of response when the therapy does confer a reduction in tumor size. Innovative molecular imaging techniques have rapidly gained importance in the dawning era of targeted therapy as they can visualize, characterize, and quantify biological processes at the cellular, subcellular, or even molecular level rather than at the anatomical level. This review summarizes different targeted cell signaling pathways, various molecular imaging techniques, and developed probes. Moreover, the application of molecular imaging for evaluating treatment response and related clinical outcome is also systematically outlined. In the future, more attention should be paid to promoting the clinical translation of molecular imaging in evaluating the sensitivity to targeted therapy with biocompatible probes. In particular, multimodal imaging technologies incorporating advanced artificial intelligence should be developed to comprehensively and accurately assess cancer-targeted therapy, in addition to RECIST-based methods.
Collapse
Affiliation(s)
- Jing-Wen Bai
- Fujian Key Laboratory of Precision Diagnosis and Treatment in Breast Cancer, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China
- Xiamen Key Laboratory of Endocrine-Related Cancer Precision Medicine, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China
- Xiamen Research Center of Clinical Medicine in Breast and Thyroid Cancers, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China
- Department of Breast-Thyroid-Surgery and Cancer Center, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China
- Department of Medical Oncology, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China
- Cancer Research Center of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China
| | - Si-Qi Qiu
- Diagnosis and Treatment Center of Breast Diseases, Clinical Research Center, Shantou Central Hospital, 515041, Shantou, China
- Guangdong Provincial Key Laboratory for Breast Cancer Diagnosis and Treatment, Shantou University Medical College, 515041, Shantou, China
| | - Guo-Jun Zhang
- Fujian Key Laboratory of Precision Diagnosis and Treatment in Breast Cancer, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China.
- Xiamen Key Laboratory of Endocrine-Related Cancer Precision Medicine, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China.
- Xiamen Research Center of Clinical Medicine in Breast and Thyroid Cancers, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China.
- Department of Breast-Thyroid-Surgery and Cancer Center, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China.
- Cancer Research Center of Xiamen University, School of Medicine, Xiamen University, 361100, Xiamen, China.
| |
Collapse
|
9
|
Sivasubramanian M, Lo LW. Assessment of Nanoparticle-Mediated Tumor Oxygen Modulation by Photoacoustic Imaging. BIOSENSORS 2022; 12:bios12050336. [PMID: 35624636 PMCID: PMC9138624 DOI: 10.3390/bios12050336] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/09/2022] [Accepted: 05/11/2022] [Indexed: 06/01/2023]
Abstract
Photoacoustic imaging (PAI) is an invaluable tool in biomedical imaging, as it provides anatomical and functional information in real time. Its ability to image at clinically relevant depths with high spatial resolution using endogenous tissues as contrast agents constitutes its major advantage. One of the most important applications of PAI is to quantify tissue oxygen saturation by measuring the differential absorption characteristics of oxy and deoxy Hb. Consequently, PAI can be utilized to monitor tumor-related hypoxia, which is a crucial factor in tumor microenvironments that has a strong influence on tumor invasiveness. Reactive oxygen species (ROS)-based therapies, such as photodynamic therapy, radiotherapy, and sonodynamic therapy, are oxygen-consuming, and tumor hypoxia is detrimental to their efficacy. Therefore, a persistent demand exists for agents that can supply oxygen to tumors for better ROS-based therapeutic outcomes. Among the various strategies, NP-mediated supplemental tumor oxygenation is especially encouraging due to its physio-chemical, tumor targeting, and theranostic properties. Here, we focus on NP-based tumor oxygenation, which includes NP as oxygen carriers and oxygen-generating strategies to alleviate hypoxia monitored by PAI. The information obtained from quantitative tumor oxygenation by PAI not only supports optimal therapeutic design but also serves as a highly effective tool to predict therapeutic outcomes.
Collapse
|
10
|
Lin L, Wang LV. The emerging role of photoacoustic imaging in clinical oncology. Nat Rev Clin Oncol 2022; 19:365-384. [PMID: 35322236 DOI: 10.1038/s41571-022-00615-3] [Citation(s) in RCA: 92] [Impact Index Per Article: 46.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/23/2022] [Indexed: 12/13/2022]
Abstract
Clinical oncology can benefit substantially from imaging technologies that reveal physiological characteristics with multiscale observations. Complementing conventional imaging modalities, photoacoustic imaging (PAI) offers rapid imaging (for example, cross-sectional imaging in real time or whole-breast scanning in 10-15 s), scalably high levels of spatial resolution, safe operation and adaptable configurations. Most importantly, this novel imaging modality provides informative optical contrast that reveals details on anatomical, functional, molecular and histological features. In this Review, we describe the current state of development of PAI and the emerging roles of this technology in cancer screening, diagnosis and therapy. We comment on the performance of cutting-edge photoacoustic platforms, and discuss their clinical applications and utility in various clinical studies. Notably, the clinical translation of PAI is accelerating in the areas of macroscopic and mesoscopic imaging for patients with breast or skin cancers, as well as in microscopic imaging for histopathology. We also highlight the potential of future developments in technological capabilities and their clinical implications, which we anticipate will lead to PAI becoming a desirable and widely used imaging modality in oncological research and practice.
Collapse
Affiliation(s)
- Li Lin
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Lihong V Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA. .,Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA.
| |
Collapse
|
11
|
Hsu HC, Wear KA, Joshua Pfefer T, Vogt WC. Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems. BIOMEDICAL OPTICS EXPRESS 2022; 13:1357-1373. [PMID: 35415004 PMCID: PMC8973174 DOI: 10.1364/boe.445702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 12/19/2021] [Accepted: 01/12/2022] [Indexed: 06/14/2023]
Abstract
Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400-1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8-24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10-50 MHz. Imaging results showed that tungsten filaments yielded 1.1-4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120-200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.
Collapse
|
12
|
Ground-glass opacity (GGO): a review of the differential diagnosis in the era of COVID-19. Jpn J Radiol 2021; 39:721-732. [PMID: 33900542 PMCID: PMC8071755 DOI: 10.1007/s11604-021-01120-w] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 04/07/2021] [Indexed: 02/06/2023]
Abstract
Thoracic imaging is fundamental in the diagnostic route of Coronavirus disease 2019 (COVID-19) especially in patients admitted to hospitals. In particular, chest computed tomography (CT) has a key role in identifying the typical features of the infection. Ground-glass opacities (GGO) are one of the main CT findings, but their presence is not specific for this viral pneumonia. In fact, GGO is a radiological sign of different pathologies with both acute and subacute/chronic clinical manifestations. In the evaluation of a subject with focal or diffuse GGO, the radiologist has to know the patient’s medical history to obtain a valid diagnostic hypothesis. The authors describe the various CT appearance of GGO, related to the onset of symptoms, focusing also on the ancillary signs that can help radiologist to obtain a correct and prompt diagnosis.
Collapse
|
13
|
De Marchi A, Pozza S, Charrier L, Cannone F, Cavallo F, Linari A, Piana R, Geniò I, Balocco P, Massè A. Small Subcutaneous Soft Tissue Tumors (<5 cm) Can Be Sarcomas and Contrast-Enhanced Ultrasound (CEUS) Is Useful to Identify Potentially Malignant Masses. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:E8868. [PMID: 33260631 PMCID: PMC7730454 DOI: 10.3390/ijerph17238868] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 11/17/2020] [Accepted: 11/25/2020] [Indexed: 11/17/2022]
Abstract
Subcutaneous masses smaller than 5 cm can be malignant, in contrast with the international guidelines. Ultrasound (US) and magnetic resonance imaging (MRI) are useful to distinguish a potentially malignant mass from the numerous benign soft tissue (ST) lesions. Contrast-enhanced ultrasound (CEUS) was applied in ST tumors, without distinguishing the subcutaneous from the deep lesions. We evaluated CEUS and MRI accuracy in comparison to histology in differentiating malignant from nonmalignant superficial ST masses, 50% smaller than 5 cm. Sensitivity, specificity, and positive and negative predictive values (PPV, NPV) with their 95% confidence intervals (CI) were calculated. Of malignant cases, 44.4% measured ≤5 cm. At univariate analysis, no statistically significant differences emerged between benign and malignant tumors in relation with clinical characteristics, except for relationship with the deep fascia (p = 0.048). MRI accuracy: sensitivity 52.8% (CI 37.0, 68.0), specificity 74.1% (CI 55.3, 86.8), PPV 73.1% (CI 53.9, 86.3), and NPV 54.1% (CI 38.4, 69.0). CEUS accuracy: sensitivity 75% (CI 58.9, 86.3), specificity 37% (CI 21.5, 55.8), PPV 61.4% (CI 46.6, 74.3), and NPV 52.6% (CI 31.7, 72.7). CEUS showed a sensitivity higher than MRI, whereas PPV and NPV were comparable. Also, masses measuring less than 5 cm can be malignant and referral criteria for centralization could be revised.
Collapse
Affiliation(s)
- Armanda De Marchi
- Department of Imaging, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino, Italy; (A.D.M.); (S.P.); (P.B.)
| | - Simona Pozza
- Department of Imaging, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino, Italy; (A.D.M.); (S.P.); (P.B.)
| | - Lorena Charrier
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5-bis, 10126 Torino, Italy;
| | - Filadelfo Cannone
- Radiology Department, Azienda Sanitaria Provinciale di Siracusa, E. Muscatello Hospital, Contrada Granatello, 96011 Augusta, Italy;
| | - Franco Cavallo
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5-bis, 10126 Torino, Italy;
| | - Alessandra Linari
- Department of Pathology, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino, Italy;
| | - Raimondo Piana
- Department of Orthopaedic, Traumatology and Rehabilitation, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino, Italy; (R.P.); (A.M.)
| | - Irene Geniò
- Department of Imaging, Azienda Ospedaliero Universitaria G. Martino, Via Consolare Valeria 1, 98100 Messina, Italy;
| | - Paolo Balocco
- Department of Imaging, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino, Italy; (A.D.M.); (S.P.); (P.B.)
| | - Alessandro Massè
- Department of Orthopaedic, Traumatology and Rehabilitation, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, CTO Hospital, Via Zuretti 29, 10126 Torino, Italy; (R.P.); (A.M.)
| |
Collapse
|