1
|
Bighi B, Ragazzini G, Gallerani A, Mescola A, Scagliarini C, Zannini C, Marcuzzi M, Olivi E, Cavallini C, Tassinari R, Bianchi M, Corsi L, Ventura C, Alessandrini A. Cell stretching devices integrated with live cell imaging: a powerful approach to study how cells react to mechanical cues. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2024; 7:012005. [PMID: 39655854 DOI: 10.1088/2516-1091/ad9699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2024] [Accepted: 11/20/2024] [Indexed: 12/18/2024]
Abstract
Mechanical stimuli have multiple effects on cell behavior, affecting a number of cellular processes including orientation, proliferation or apoptosis, migration and invasion, the production of extracellular matrix proteins, the activation and translocation of transcription factors, the expression of different genes such as those involved in inflammation and the reprogramming of cell fate. The recent development of cell stretching devices has paved the way for the study of cell reactions to stretching stimuliin-vitro, reproducing physiological situations that are experienced by cells in many tissues and related to functions such as breathing, heart beating and digestion. In this work, we review the highly-relevant contributions cell stretching devices can provide in the field of mechanobiology. We then provide the details for the in-house construction and operation of these devices, starting from the systems that we already developed and tested. We also review some examples where cell stretchers can supply meaningful insights into mechanobiology topics and we introduce new results from our exploitation of these devices.
Collapse
Affiliation(s)
- Beatrice Bighi
- Department of Physics, Informatics and Mathematics, University of Modena and Reggio Emilia, via Campi 213/A, 41125 Modena, Italy
- CNR-Nanoscience Institute-S3, via Campi 213/A, 41125 Modena, Italy
| | | | - Alessia Gallerani
- Department of Physics, Informatics and Mathematics, University of Modena and Reggio Emilia, via Campi 213/A, 41125 Modena, Italy
| | - Andrea Mescola
- CNR-Nanoscience Institute-S3, via Campi 213/A, 41125 Modena, Italy
| | - Chiara Scagliarini
- Department of Physics, Informatics and Mathematics, University of Modena and Reggio Emilia, via Campi 213/A, 41125 Modena, Italy
| | - Chiara Zannini
- Eldor Lab, via di Corticella 183, 40128 Bologna, Italy
- National Laboratory of Molecular Biology and Stem Cell Engineering, National Institute of Biostructures and Biosystems (I.N.B.B.), via di Corticella 183, 40128 Bologna, Italy
| | - Martina Marcuzzi
- Department of Medical and Surgical Sciences, University of Bologna, via G. Massarenti 9, Bologna 40138, Italy
| | - Elena Olivi
- Eldor Lab, via di Corticella 183, 40128 Bologna, Italy
| | - Claudia Cavallini
- Eldor Lab, via di Corticella 183, 40128 Bologna, Italy
- National Laboratory of Molecular Biology and Stem Cell Engineering, National Institute of Biostructures and Biosystems (I.N.B.B.), via di Corticella 183, 40128 Bologna, Italy
| | | | - Michele Bianchi
- Department of Life Sciences, University of Modena and Reggio Emilia, Via G. Campi 287, 41125 Modena, Italy
| | - Lorenzo Corsi
- Department of Life Sciences, University of Modena and Reggio Emilia, Via G. Campi 287, 41125 Modena, Italy
| | - Carlo Ventura
- Eldor Lab, via di Corticella 183, 40128 Bologna, Italy
- National Laboratory of Molecular Biology and Stem Cell Engineering, National Institute of Biostructures and Biosystems (I.N.B.B.), via di Corticella 183, 40128 Bologna, Italy
| | - Andrea Alessandrini
- Department of Physics, Informatics and Mathematics, University of Modena and Reggio Emilia, via Campi 213/A, 41125 Modena, Italy
- CNR-Nanoscience Institute-S3, via Campi 213/A, 41125 Modena, Italy
| |
Collapse
|
2
|
Yadav S, Singha P, Nguyen NK, Ooi CH, Kashaninejad N, Nguyen NT. Uniaxial Cyclic Cell Stretching Device for Accelerating Cellular Studies. MICROMACHINES 2023; 14:1537. [PMID: 37630073 PMCID: PMC10456305 DOI: 10.3390/mi14081537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 07/24/2023] [Accepted: 07/29/2023] [Indexed: 08/27/2023]
Abstract
Cellular response to mechanical stimuli is a crucial factor for maintaining cell homeostasis. The interaction between the extracellular matrix and mechanical stress plays a significant role in organizing the cytoskeleton and aligning cells. Tools that apply mechanical forces to cells and tissues, as well as those capable of measuring the mechanical properties of biological cells, have greatly contributed to our understanding of fundamental mechanobiology. These tools have been extensively employed to unveil the substantial influence of mechanical cues on the development and progression of various diseases. In this report, we present an economical and high-performance uniaxial cell stretching device. This paper reports the detailed operation concept of the device, experimental design, and characterization. The device was tested with MDA-MB-231 breast cancer cells. The experimental results agree well with previously documented morphological changes resulting from stretching forces on cancer cells. Remarkably, our new device demonstrates comparable cellular changes within 30 min compared with the previous 2 h stretching duration. This third-generation device significantly improved the stretching capabilities compared with its previous counterparts, resulting in a remarkable reduction in stretching time and a substantial increase in overall efficiency. Moreover, the device design incorporates an open-source software interface, facilitating convenient parameter adjustments such as strain, stretching speed, frequency, and duration. Its versatility enables seamless integration with various optical microscopes, thereby yielding novel insights into the realm of mechanobiology.
Collapse
Affiliation(s)
| | | | | | | | | | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre (QMNC), Griffith University, Nathan, QLD 4111, Australia; (S.Y.); (P.S.); (N.-K.N.); (C.H.O.); (N.K.)
| |
Collapse
|
3
|
Stewart L, Turner NA. Channelling the Force to Reprogram the Matrix: Mechanosensitive Ion Channels in Cardiac Fibroblasts. Cells 2021; 10:990. [PMID: 33922466 PMCID: PMC8145896 DOI: 10.3390/cells10050990] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/13/2021] [Accepted: 04/21/2021] [Indexed: 02/06/2023] Open
Abstract
Cardiac fibroblasts (CF) play a pivotal role in preserving myocardial function and integrity of the heart tissue after injury, but also contribute to future susceptibility to heart failure. CF sense changes to the cardiac environment through chemical and mechanical cues that trigger changes in cellular function. In recent years, mechanosensitive ion channels have been implicated as key modulators of a range of CF functions that are important to fibrotic cardiac remodelling, including cell proliferation, myofibroblast differentiation, extracellular matrix turnover and paracrine signalling. To date, seven mechanosensitive ion channels are known to be functional in CF: the cation non-selective channels TRPC6, TRPM7, TRPV1, TRPV4 and Piezo1, and the potassium-selective channels TREK-1 and KATP. This review will outline current knowledge of these mechanosensitive ion channels in CF, discuss evidence of the mechanosensitivity of each channel, and detail the role that each channel plays in cardiac remodelling. By better understanding the role of mechanosensitive ion channels in CF, it is hoped that therapies may be developed for reducing pathological cardiac remodelling.
Collapse
Affiliation(s)
| | - Neil A. Turner
- Discovery and Translational Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, School of Medicine, University of Leeds, Leeds LS2 9JT, UK;
| |
Collapse
|
4
|
Kah D, Winterl A, Přechová M, Schöler U, Schneider W, Friedrich O, Gregor M, Fabry B. A low-cost uniaxial cell stretcher for six parallel wells. HARDWAREX 2021; 9:e00162. [PMID: 35492050 PMCID: PMC9041267 DOI: 10.1016/j.ohx.2020.e00162] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 12/02/2020] [Accepted: 12/03/2020] [Indexed: 05/22/2023]
Abstract
Cells in the lungs, the heart, and numerous other organs, are constantly exposed to dynamic forces and deformations. To mimic these dynamic mechanical loading conditions and to study the resulting cellular responses such as morphological changes or the activation of biochemical signaling pathways, cells are typically seeded on flexible 2D substrates that are uniaxially or biaxially stretched. Here, we present an open-source cell stretcher built from parts of an Anet A8 3D printer. The cell stretcher is controlled by a fully programmable open-source software using GCode and Python. Up to six flexible optically clear substrates can be stretched simultaneously, allowing for comparative multi-batch biological studies including microscopic image analysis. The cell yield from the cell culture area of 4 cm2 per substrate is sufficient for Western-blot protein analysis. As a proof-of-concept, we study the activation of the Yes-associated protein (YAP) mechanotransduction pathway in response to increased cytoskeletal tension induced by uniaxial stretching of epithelial cells. Our data support the previously observed activation of the YAP transcription pathway by stretch-induced increase in cytoskeletal tension and demonstrate the suitability of the cell stretcher to study complex mechano-biological processes.
Collapse
Affiliation(s)
- Delf Kah
- Biophysics Group, Department of Physics, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Alexander Winterl
- Biophysics Group, Department of Physics, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Magdalena Přechová
- Laboratory of Integrative Biology, Institute of Molecular Genetics of the Czech Academy of Sciences, Prague, Czech Republic
| | - Ulrike Schöler
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, FAU, Erlangen, Germany
- School in Advanced Optical Technologies, FAU, Erlangen, Germany
| | - Werner Schneider
- Biophysics Group, Department of Physics, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Oliver Friedrich
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, FAU, Erlangen, Germany
- School in Advanced Optical Technologies, FAU, Erlangen, Germany
| | - Martin Gregor
- Laboratory of Integrative Biology, Institute of Molecular Genetics of the Czech Academy of Sciences, Prague, Czech Republic
| | - Ben Fabry
- Biophysics Group, Department of Physics, Friedrich-Alexander University Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
5
|
A Fully Integrated Arduino-Based System for the Application of Stretching Stimuli to Living Cells and Their Time-Lapse Observation: A Do-It-Yourself Biology Approach. Ann Biomed Eng 2021; 49:2243-2259. [PMID: 33728867 DOI: 10.1007/s10439-021-02758-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 02/20/2021] [Indexed: 10/21/2022]
Abstract
Mechanobiology has nowadays acquired the status of a topic of fundamental importance in a degree in Biological Sciences. It is inherently a multidisciplinary topic where biology, physics and engineering competences are required. A course in mechanobiology should include lab experiences where students can appreciate how mechanical stimuli from outside affect living cell behaviour. Here we describe all the steps to build a cell stretcher inside an on-stage cell incubator. This device allows exposing living cells to a periodic mechanical stimulus similar to what happens in physiological conditions such as, for example, in the vascular system or in the lungs. The reaction of the cells to the periodic mechanical stretching represents a prototype of a mechanobiological signal integrated by living cells. We also provide the theoretical and experimental aspects related to the calibration of the stretcher apparatus at a level accessible to researchers not used to dealing with topics like continuum mechanics and analysis of deformations. We tested our device by stretching cells of two different lines, U87-MG and Balb-3T3 cells, and we analysed and discussed the effect of the periodic stimulus on both cell reorientation and migration. We also discuss the basic aspects related to the quantitative analysis of the reorientation process and of cell migration. We think that the device we propose can be easily reproduced at low-cost within a project-oriented course in the fields of biology, biotechnology and medical engineering.
Collapse
|
6
|
Li X, Garcia-Elias A, Benito B, Nattel S. The effects of cardiac stretch on atrial fibroblasts: Analysis of the evidence and potential role in atrial fibrillation. Cardiovasc Res 2021; 118:440-460. [PMID: 33576384 DOI: 10.1093/cvr/cvab035] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 11/27/2020] [Accepted: 02/09/2021] [Indexed: 01/06/2023] Open
Abstract
Atrial fibrillation (AF) is an important clinical problem. Chronic pressure/volume overload of the atria promotes AF, particularly via enhanced extracellular matrix (ECM) accumulation manifested as tissue fibrosis. Loading of cardiac cells causes cell-stretch that is generally considered to promote fibrosis by directly activating fibroblasts, the key cell-type responsible for ECM-production. The primary purpose of this article is to review the evidence regarding direct effects of stretch on cardiac fibroblasts, specifically: (i) the similarities and differences among studies in observed effects of stretch on cardiac-fibroblast function; (ii) the signaling-pathways implicated; and (iii) the factors that affect stretch-related phenotypes. Our review summarizes the most important findings and limitations in this area and gives an overview of clinical data and animal models related to cardiac stretch, with particular emphasis on the atria. We suggest that the evidence regarding direct fibroblast activation by stretch is weak and inconsistent, in part because of variability among studies in key experimental conditions that govern the results. Further work is needed to clarify whether, in fact, stretch induces direct activation of cardiac fibroblasts and if so, to elucidate the determining factors to ensure reproducible results. If mechanical load on fibroblasts proves not to be clearly profibrotic by direct actions, other mechanisms like paracrine influences, the effects of systemic mediators and/or the direct consequences of myocardial injury or death, might account for the link between cardiac stretch and fibrosis. Clarity in this area is needed to improve our understanding of AF pathophysiology and assist in therapeutic development.
Collapse
Affiliation(s)
- Xixiao Li
- Department of Medicine and Research Center, Montreal Heart Institute, Montreal, Canada.,Department of Pharmacology and Therapeutics, McGill University, Montreal, Canada
| | - Anna Garcia-Elias
- Department of Medicine and Research Center, Montreal Heart Institute, Montreal, Canada
| | - Begoña Benito
- Vascular Biology and Metabolism Program, Vall d'Hebrón Research Institute (VHIR), Barcelona, Spain.,Cardiology Department, Hospital Universitari Vall d'Hebrón, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Stanley Nattel
- Department of Medicine and Research Center, Montreal Heart Institute, Montreal, Canada.,Department of Pharmacology and Therapeutics, McGill University, Montreal, Canada.,Department of Pharmacology and Physiology of the Université de Montréal Faculty of Medicine, Montreal, Canada.,Institute of Pharmacology, West German Heart and Vascular Center, Faculty of Medicine, University Duisburg-Essen, Essen, Germany.,IHU LIRYC and Fondation Bordeaux Université, Bordeaux, France
| |
Collapse
|
7
|
Martinac B, Nikolaev YA, Silvani G, Bavi N, Romanov V, Nakayama Y, Martinac AD, Rohde P, Bavi O, Cox CD. Cell membrane mechanics and mechanosensory transduction. CURRENT TOPICS IN MEMBRANES 2020; 86:83-141. [DOI: 10.1016/bs.ctm.2020.08.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
8
|
Atcha H, Davis CT, Sullivan NR, Smith TD, Anis S, Dahbour WZ, Robinson ZR, Grosberg A, Liu WF. A Low-Cost Mechanical Stretching Device for Uniaxial Strain of Cells: A Platform for Pedagogy in Mechanobiology. J Biomech Eng 2018; 140:2678940. [PMID: 30003248 PMCID: PMC6056193 DOI: 10.1115/1.4039949] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 03/30/2018] [Indexed: 11/08/2022]
Abstract
Mechanical cues including stretch, compression, and shear stress play a critical role in regulating the behavior of many cell types, particularly those that experience substantial mechanical stress within tissues. Devices that impart mechanical stimulation to cells in vitro have been instrumental in helping to develop a better understanding of how cells respond to mechanical forces. However, these devices often have constraints, such as cost and limited functional capabilities, that restrict their use in research or educational environments. Here, we describe a low-cost method to fabricate a uniaxial cell stretcher that would enable widespread use and facilitate engineering design and mechanobiology education for undergraduate students. The device is capable of producing consistent and reliable strain profiles through the use of a servomotor, gear, and gear rack system. The servomotor can be programmed to output various waveforms at specific frequencies and stretch amplitudes by controlling the degree of rotation, speed, and acceleration of the servogear. In addition, the stretchable membranes are easy to fabricate and can be customized, allowing for greater flexibility in culture well size. We used the custom-built stretching device to uniaxially strain macrophages and cardiomyocytes, and found that both cell types displayed functional and cell shape changes that were consistent with the previous studies using commercially available systems. Overall, this uniaxial cell stretcher provides a more cost-effective alternative to study the effects of mechanical stretch on cells, and can therefore, be widely used in research and educational environments to broaden the study and pedagogy of cell mechanobiology.
Collapse
Affiliation(s)
- Hamza Atcha
- Department of Biomedical Engineering,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
| | - Chase T. Davis
- Department of Biomedical Engineering,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
| | - Nicholas R. Sullivan
- Department of Biomedical Engineering,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
| | - Tim D. Smith
- Department of Biomedical Engineering,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
| | - Sara Anis
- Department of Biomedical Engineering,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
| | - Waleed Z. Dahbour
- Department of Biomedical Engineering,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
| | - Zachery R. Robinson
- Department of Biomedical Engineering,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
| | - Anna Grosberg
- Department of Biomedical Engineering,Center for Complex Biological Systems,
The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
- Department of Chemical Engineeringand Materials Science,
University of California Irvine,
Irvine, CA 92697
e-mail:
| | - Wendy F. Liu
- Department of Biomedical Engineering,The Edwards Lifesciences Center for
Advanced Cardiovascular Technology,
University of California Irvine,
Irvine, CA 92697
- Department of Chemical Engineeringand Materials Science,
University of California Irvine,
Irvine, CA 92697
e-mail:
| |
Collapse
|
9
|
Nguyen-Truong M, Wang Z. Biomechanical Properties and Mechanobiology of Cardiac ECM. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1098:1-19. [PMID: 30238363 DOI: 10.1007/978-3-319-97421-7_1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
The heart is comprised of cardiac cells and extracellular matrix (ECM) which function together to pump blood throughout the body, provide organs with nutrients and oxygen, and remove metabolic wastes. Cardiac ECM provides a scaffold to cardiac cells and contributes to the mechanical properties and function of the cardiac tissue. Recently, more evidence suggests that cardiac ECM plays an active role in cardiac remodeling in response to mechanical loads. To that end, we provide an overview of the structure and function of the heart and the currently available in vivo and ex vivo mechanical measurements of cardiac tissues. We also review the biomechanical properties of cardiac tissues including the myocardium and heart valves, with a discussion on the differences between the right ventricle and left ventricle. Lastly, we go into the mechanical factors involved in cardiac remodeling and review the mechanobiology of cardiac tissues, i.e., the biomechanical responses at the cellular and tissue level, with an emphasis on the impact on the cardiac ECM. The regulation of cardiac ECM on cell function, which is a new and open area of research, is also briefly discussed. Future investigation into the ECM deposition and the interaction of cardiac cells and ECM components for mechanotransduction can assist to understand cardiac remodeling and inspire new therapies for cardiac diseases.
Collapse
Affiliation(s)
| | - Zhijie Wang
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA. .,Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA.
| |
Collapse
|
10
|
Adding dimension to cellular mechanotransduction: Advances in biomedical engineering of multiaxial cell-stretch systems and their application to cardiovascular biomechanics and mechano-signaling. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2017. [DOI: 10.1016/j.pbiomolbio.2017.06.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
11
|
|
12
|
Ugolini GS, Rasponi M, Pavesi A, Santoro R, Kamm R, Fiore GB, Pesce M, Soncini M. On-chip assessment of human primary cardiac fibroblasts proliferative responses to uniaxial cyclic mechanical strain. Biotechnol Bioeng 2016; 113:859-869. [PMID: 26444553 DOI: 10.1002/bit.25847] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 08/29/2015] [Accepted: 09/29/2015] [Indexed: 01/05/2025]
Abstract
Cardiac cell function is substantially influenced by the nature and intensity of the mechanical loads the cells experience. Cardiac fibroblasts (CFs) are primarily involved in myocardial tissue remodeling: at the onset of specific pathological conditions, CFs activate, proliferate, differentiate, and critically alter the amount of myocardial extra-cellular matrix with important consequences for myocardial functioning. While cyclic mechanical strain has been shown to increase matrix synthesis of CFs in vitro, the role of mechanical cues in CFs proliferation is unclear. We here developed a multi-chamber cell straining microdevice for cell cultures under uniform, uniaxial cyclic strain. After careful characterization of the strain field, we extracted human heart-derived CFs and performed cyclic strain experiments. We subjected cells to 2% or 8% cyclic strain for 24 h or 72 h, using immunofluorescence to investigate markers of cell morphology, cell proliferation (Ki67, EdU, phospho-Histone-H3) and subcellular localization of the mechanotransduction-associated transcription factor YAP. Cell morphology was affected by cyclic strain in terms of cell area, cell and nuclear shape and cellular alignment. We additionally observed a strain intensity-dependent control of cell growth: a significant proliferation increase occurred at 2% cyclic strain, while time-dependent effects took place upon 8% cyclic strain. The YAP-dependent mechano-transduction pathway was similarly activated in both strain conditions. These results demonstrate a differential effect of cyclic strain intensity on human CFs proliferation control and provide insights into the YAP-dependent mechano-sensing machinery of human CFs.
Collapse
Affiliation(s)
| | - Marco Rasponi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Andrea Pavesi
- BioSyM IRG, Singapore-MIT Alliance for Research and Technology, Singapore
| | - Rosaria Santoro
- Unità di Ingegneria Tissutale Cardiovascolare, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Roger Kamm
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts
| | | | - Maurizio Pesce
- Unità di Ingegneria Tissutale Cardiovascolare, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Monica Soncini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
13
|
Schürmann S, Wagner S, Herlitze S, Fischer C, Gumbrecht S, Wirth-Hücking A, Prölß G, Lautscham LA, Fabry B, Goldmann WH, Nikolova-Krstevski V, Martinac B, Friedrich O. The IsoStretcher: An isotropic cell stretch device to study mechanical biosensor pathways in living cells. Biosens Bioelectron 2016; 81:363-372. [PMID: 26991603 DOI: 10.1016/j.bios.2016.03.015] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Revised: 03/07/2016] [Accepted: 03/08/2016] [Indexed: 12/31/2022]
Abstract
Mechanosensation in many organs (e.g. lungs, heart, gut) is mediated by biosensors (like mechanosensitive ion channels), which convert mechanical stimuli into electrical and/or biochemical signals. To study those pathways, technical devices are needed that apply strain profiles to cells, and ideally allow simultaneous live-cell microscopy analysis. Strain profiles in organs can be complex and multiaxial, e.g. in hollow organs. Most devices in mechanobiology apply longitudinal uniaxial stretch to adhered cells using elastomeric membranes to study mechanical biosensors. Recent approaches in biomedical engineering have employed intelligent systems to apply biaxial or multiaxial stretch to cells. Here, we present an isotropic cell stretch system (IsoStretcher) that overcomes some previous limitations. Our system uses a rotational swivel mechanism that translates into a radial displacement of hooks attached to small circular silicone membranes. Isotropicity and focus stability are demonstrated with fluorescent beads, and transmission efficiency of elastomer membrane stretch to cellular area change in HeLa/HEK cells. Applying our system to lamin-A overexpressing fibrosarcoma cells, we found a markedly reduced stretch of cell area, indicative of a stiffer cytoskeleton. We also investigated stretch-activated Ca(2+) entry into atrial HL-1 myocytes. 10% isotropic stretch induced robust oscillating increases in intracellular Fluo-4 Ca(2+) fluorescence. Store-operated Ca(2+) entry was not detected in these cells. The Isostretcher provides a useful versatile tool for mechanobiology.
Collapse
Affiliation(s)
- S Schürmann
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany
| | - S Wagner
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany; Department of Physics, Biophysics Group, FAU, Henkestr. 91, 91052 Erlangen, Germany
| | - S Herlitze
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany
| | - C Fischer
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany
| | - S Gumbrecht
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany
| | - A Wirth-Hücking
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany
| | - G Prölß
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany
| | - L A Lautscham
- Department of Physics, Biophysics Group, FAU, Henkestr. 91, 91052 Erlangen, Germany
| | - B Fabry
- Department of Physics, Biophysics Group, FAU, Henkestr. 91, 91052 Erlangen, Germany
| | - W H Goldmann
- Department of Physics, Biophysics Group, FAU, Henkestr. 91, 91052 Erlangen, Germany
| | - V Nikolova-Krstevski
- Molecular Cardiology Division, Victor Chang Cardiac Research Institute, 405 Liverpool St, Darlinghurst, NSW 2010 Sydney, Australia
| | - B Martinac
- Mechanosensory Biophysics Laboratory, Victor Chang Cardiac Research Institute, Darlinghurst NSW 2010, Australia; St Vincent's Clinical School, University of New South Wales, Darlinghurst NSW 2010, Australia
| | - O Friedrich
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str.3, 91052 Erlangen, Germany.
| |
Collapse
|
14
|
Aydin O, Aksoy B, Akalin OB, Bayraktar H, Alaca BE. Time-resolved local strain tracking microscopy for cell mechanics. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:023905. [PMID: 26931864 DOI: 10.1063/1.4941715] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A uniaxial cell stretching technique to measure time-resolved local substrate strain while simultaneously imaging adherent cells is presented. The experimental setup comprises a uniaxial stretcher platform compatible with inverted microscopy and transparent elastomer samples with embedded fluorescent beads. This integration enables the acquisition of real-time spatiotemporal data, which is then processed using a single-particle tracking algorithm to track the positions of fluorescent beads for the subsequent computation of local strain. The present local strain tracking method is demonstrated using polydimethylsiloxane (PDMS) samples of rectangular and dogbone geometries. The comparison of experimental results and finite element simulations for the two sample geometries illustrates the capability of the present system to accurately quantify local deformation even when the strain distribution is non-uniform over the sample. For a regular dogbone sample, the experimentally obtained value of local strain at the center of the sample is 77%, while the average strain calculated using the applied cross-head displacement is 48%. This observation indicates that considerable errors may arise when cross-head measurement is utilized to estimate strain in the case of non-uniform sample geometry. Finally, the compatibility of the proposed platform with biological samples is tested using a unibody PDMS sample with a well to contain cells and culture media. HeLa S3 cells are plated on collagen-coated samples and cell adhesion and proliferation are observed. Samples with adherent cells are then stretched to demonstrate simultaneous cell imaging and tracking of embedded fluorescent beads.
Collapse
Affiliation(s)
- O Aydin
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sariyer 34450 Istanbul, Turkey
| | - B Aksoy
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sariyer 34450 Istanbul, Turkey
| | - O B Akalin
- Biomedical Science and Engineering, Koç University, Rumelifeneri Yolu, Sariyer 34450 Istanbul, Turkey
| | - H Bayraktar
- Biomedical Science and Engineering, Koç University, Rumelifeneri Yolu, Sariyer 34450 Istanbul, Turkey
| | - B E Alaca
- Department of Mechanical Engineering, Koç University, Rumelifeneri Yolu, Sariyer 34450 Istanbul, Turkey
| |
Collapse
|
15
|
A Uniaxial Cell Stretcher In Vitro Model Simulating Tissue Expansion of Plastic Surgery. J Craniofac Surg 2013; 24:1431-5. [DOI: 10.1097/scs.0b013e31828dcc1f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
16
|
Wang Y, Fang Q, Lu Y, Song B, Li W, Li L. Effects of mechanical stretch on interstitial cells of Cajal in guinea pig bladder. J Surg Res 2010; 164:e213-9. [PMID: 20828727 DOI: 10.1016/j.jss.2010.04.040] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2010] [Revised: 04/10/2010] [Accepted: 04/21/2010] [Indexed: 11/18/2022]
Abstract
OBJECTIVES C-kit positive interstitial cells of Cajal (ICCs) play an important role in the regulation of the smooth muscle motility. In this study, we investigated the mechanical sensitivity of ICCs in guinea pig bladder and their possible relationship with detrusor overactivity (DO). METHODS Stretch load was performed in vivo in DO models produced by 4 wk of partial bladder outlet obstruction (PBOO). Number and morphology of ICCs were examined using a specific ICC marker, c-kit, immunochemistry staining. The spontaneous and stretch-induced calcium transients (SICT) of ICCs were investigated in cells cultured onto flexible silicone membranes preloaded with the Ca(2+) indicator fluo-4AM in vitro. RESULTS C-kit positive ICCs were mainly located along and between bladder smooth muscle bundles. ICCs in DO bladders displayed more lateral branching with mutual connections. The number of c-kit positive bladder ICCs was increased in the DO group compared with the control group (n = 50, P < 0.05). Cultured ICCs from DO bladders showed spontaneous calcium waves with higher frequency and lower amplitude than those from control bladders (n = 15, P < 0.05). Significant SICT were detected in cultured bladder ICCs. SICT generated in ICCs from DO were more likely to transfer to adjacent smooth muscle cells through cell membrane connection than ICCs from control bladders. CONCLUSIONS Long-term overload tension following PBOO caused changes in morphology, quantity and spontaneous calcium transients of ICCs in guinea pig bladder. Mechanical sensitivity and interaction with SMC of ICCs may contribute to the mechanosensitive conductances in bladder regulation, and may play a role in the pathogenesis of DO.
Collapse
Affiliation(s)
- Yongquan Wang
- Center of Urology, Southwest Hospital, Third Military Medical University, Chongqing, China
| | | | | | | | | | | |
Collapse
|
17
|
Tissue Engineering. Plast Reconstr Surg 2010. [DOI: 10.1007/978-1-84882-513-0_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
18
|
Shimko VF, Claycomb WC. Effect of mechanical loading on three-dimensional cultures of embryonic stem cell-derived cardiomyocytes. Tissue Eng Part A 2008. [PMID: 18333804 DOI: 10.1089/ten.2007.0092] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Cardiomyocytes selected from murine embryonic stem cells (ESCs) using the cardiac-specific promoter alpha-myosin heavy chain were embedded into collagen and fibronectin scaffolds. A custom-built device was used to expose these constructs to mechanical loading (10% stretch at 1, 2, or 3 Hz) or no loading. Constructs were evaluated using reverse transcriptase polymerase chain reaction, histology, and immunohistochemistry. Mechanical loading significantly affected gene expression, and these changes were dependent on the frequency of stretch. A 1 Hz cyclical stretch resulted in significantly lower gene expression, whereas a 3 Hz cyclical stretch resulted in significantly greater gene expression than in unstretched controls. These constructs also developed cardiac-specific cell structures similar to those found in vivo. This study describes a 3-dimensional model to examine the direct effect of mechanical loading on the differentiation of ESC-derived cardiomyocytes embedded in a defined extracellular matrix scaffold. A technique was also developed to isolate the areas within the constructs undergoing the most homogeneous strain so that the effect of mechanical loading on gene expression could be directly evaluated. These experiments emphasize that ESC-derived cardiomyocytes are actively responding to cues from their environment and that those cues can drive phenotypic control and cardiomyocyte differentiation.
Collapse
Affiliation(s)
- Valerie F Shimko
- Department of Biomedical Engineering, Tulane University, New Orleans, Louisiana, USA
| | | |
Collapse
|
19
|
Shimko VF, Claycomb WC. Effect of mechanical loading on three-dimensional cultures of embryonic stem cell-derived cardiomyocytes. Tissue Eng Part A 2008; 14:49-58. [PMID: 18333804 DOI: 10.1089/ten.a.2007.0092] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Cardiomyocytes selected from murine embryonic stem cells (ESCs) using the cardiac-specific promoter alpha-myosin heavy chain were embedded into collagen and fibronectin scaffolds. A custom-built device was used to expose these constructs to mechanical loading (10% stretch at 1, 2, or 3 Hz) or no loading. Constructs were evaluated using reverse transcriptase polymerase chain reaction, histology, and immunohistochemistry. Mechanical loading significantly affected gene expression, and these changes were dependent on the frequency of stretch. A 1 Hz cyclical stretch resulted in significantly lower gene expression, whereas a 3 Hz cyclical stretch resulted in significantly greater gene expression than in unstretched controls. These constructs also developed cardiac-specific cell structures similar to those found in vivo. This study describes a 3-dimensional model to examine the direct effect of mechanical loading on the differentiation of ESC-derived cardiomyocytes embedded in a defined extracellular matrix scaffold. A technique was also developed to isolate the areas within the constructs undergoing the most homogeneous strain so that the effect of mechanical loading on gene expression could be directly evaluated. These experiments emphasize that ESC-derived cardiomyocytes are actively responding to cues from their environment and that those cues can drive phenotypic control and cardiomyocyte differentiation.
Collapse
Affiliation(s)
- Valerie F Shimko
- Department of Biomedical Engineering, Tulane University, New Orleans, Louisiana, USA
| | | |
Collapse
|
20
|
Yeh AT, Gibbs H, Hu JJ, Larson AM. Advances in Nonlinear Optical Microscopy for Visualizing Dynamic Tissue Properties in Culture. TISSUE ENGINEERING PART B-REVIEWS 2008; 14:119-31. [DOI: 10.1089/teb.2007.0284] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Alvin T. Yeh
- Department of Biomedical Engineering, Texas A & M University, College Staion, Texas
| | - Holly Gibbs
- Department of Biomedical Engineering, Texas A & M University, College Staion, Texas
| | - Jin-Jia Hu
- Department of Biomedical Engineering, Texas A & M University, College Staion, Texas
| | - Adam M. Larson
- Department of Biomedical Engineering, Texas A & M University, College Staion, Texas
| |
Collapse
|
21
|
Yan W, George S, Fotadar U, Tyhovych N, Kamer A, Yost MJ, Price RL, Haggart CR, Holmes JW, Terracio L. Tissue engineering of skeletal muscle. ACTA ACUST UNITED AC 2008; 13:2781-90. [PMID: 17880268 DOI: 10.1089/ten.2006.0408] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Loss of skeletal muscle profoundly affects the health and well-being of patients, and there currently is no way to replace lost muscle. We believe that a key step in the development of a prosthesis for reconstruction of dysfunctional muscular tissue is the ability to reconstitute the in vivo-like 3-dimensional (3D) organization of skeletal muscle in vitro with isolated satellite cells. In our present proof of principle studies, we have successfully constructed a multilayered culture of skeletal muscle cells, derived from neonatal satellite cells, that are distributed in a 3D pattern of organization that mimics many of the features of intact tissue. These multilayered cultures are composed of elongated multinucleated myotubes that are MyoD positive. Histological studies indicate that the multiple layers of myotubes can be distinguished. Expression of muscle-specific markers such as myosin heavy chain, dystrophin, integrin alpha-7, alpha-enolase, and beta-enolase was detected using real-time reverse transcriptase polymerase chain reaction at levels near adult values. Physiological measurements of the engineered skeletal muscle showed that they tetanize and display physiologic force length behavior, although developed force per cross-sectional area was below that of native rat skeletal muscle.
Collapse
Affiliation(s)
- Wentao Yan
- Department of Basic Sciences, New York University, New York, New York 10010, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Reinhart‐King CA, Fujiwara K, Berk BC. Chapter 2 Physiologic Stress‐Mediated Signaling in the Endothelium. Methods Enzymol 2008; 443:25-44. [DOI: 10.1016/s0076-6879(08)02002-8] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
23
|
Husse B, Briest W, Homagk L, Isenberg G, Gekle M. Cyclical mechanical stretch modulates expression of collagen I and collagen III by PKC and tyrosine kinase in cardiac fibroblasts. Am J Physiol Regul Integr Comp Physiol 2007; 293:R1898-907. [PMID: 17686880 DOI: 10.1152/ajpregu.00804.2006] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Mechanical load and chemical factors as stimuli for the different pattern of the extracellular matrix (ECM) could be responsible for cardiac dysfunction. Since fibroblasts can both synthesize and degrade ECM, ventricular fibroblasts from adult rat hearts underwent cyclical mechanical stretch (CMS; 0.33 Hz) by three different elongations (3%, 6%, 9%) and four different serum concentrations (0%, 0.5%, 5%, 10%) within 24 h. Expression of collagen I and III, as well as matrix metalloproteinase-2 (MMP-2), tissue inhibitor of MMP-2 (TIMP-2), and colligin were analyzed by RNase protection assay. In the absence of serum, 9% CMS increased the mRNA of collagen I by 1.70-fold and collagen III by 1.64-fold. This increase was prevented by the inhibition either of PKC or of tyrosine kinase but not of PKA. Inhibition of PKC or tyrosine kinase itself reduced the expression of collagen I and collagen III mRNA. The mRNA of MMP-2, TIMP-2, and colligin showed the same tendency by stretch. Combined with 10% serum, 6% CMS reduced the mRNA of collagen I (0.62-fold) and collagen III (0.79-fold). Inhibition of PKC or tyrosine kinase, but not of PKA, prevented the reduction of collagen I and collagen III mRNA in 10% serum. The results show that the response of fibroblasts to CMS depends on the serum concentration. At least two signaling pathways are involved in the stretch-induced ECM regulation. Myocardial fibrosis due to ECM remodeling contributes to the dysfunction of the failing heart, which might be attributed to changes in hemodynamic loading.
Collapse
Affiliation(s)
- Britta Husse
- Julius-Bernstein-Institute of Physiology, Martin-Luther-University of Halle, Germany.
| | | | | | | | | |
Collapse
|
24
|
Bullard TA, Hastings JL, Davis JM, Borg TK, Price RL. Altered PKC expression and phosphorylation in response to the nature, direction, and magnitude of mechanical stretch. Can J Physiol Pharmacol 2007; 85:243-50. [PMID: 17487266 DOI: 10.1139/y07-023] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Protein kinase C (PKC) isozymes have been shown to play a role in mechanotransduction in a variety of cell types. We sought to identify the PKC isozymes involved in transducing mechanical (cyclic vs. static), direction and intensity of stretch by examining changes in protein expression and phosphorylation. We used a 3-dimensional culture system with aligned neonatal rat cardiac myocytes on silastic membranes. Myocytes were subjected to either cyclic stretch at 5 cycles/min or static stretch for a period of 24 h at intensities of 0%, 2.5%, 5%, or 10% of full membrane length. Stretch was applied in perpendicular or parallel directions to myocyte alignment. PKC delta was most sensitive to stretch applied perpendicular to myocyte alignment regardless of the nature of stretch, while phospho PKC delta T505 increased in response to static-perpendicular stretch. PKC epsilon expression was altered by cyclic stretch but not static stretch, while phospho PKC epsilon S719 remained unchanged. PKC alpha expression was not altered by stretch; however, phospho PKC alpha S657 increased in a dose-dependent manner following cyclic-perpendicular stretch. Our results indicate that changes in PKC expression and phosphorylation state may be a mechanism for cardiac myocytes to discriminate between the nature, direction, and intensity of mechanical stretch.
Collapse
Affiliation(s)
- Tara A Bullard
- Department of Cell and Developmental Biology and Anatomy, University of South Carolina, School of Medicine, 6439 Garners Ferry Road, Columbia, SC 29209, USA.
| | | | | | | | | |
Collapse
|
25
|
Cha JM, Park SN, Noh SH, Suh H. Time-dependent Modulation of Alignment and Differentiation of Smooth Muscle Cells Seeded on a Porous Substrate Undergoing Cyclic Mechanical Strain. Artif Organs 2006; 30:250-8. [PMID: 16643383 DOI: 10.1111/j.1525-1594.2006.00212.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
The orientation of cellular alignment in smooth muscle tissue engineering is directly related to optimal movement of engineered tissue when it is transplanted in vivo. Cyclic mechanical strain has been applied to modulate the alignment, proliferation, and differentiation of smooth muscle cells. This study was conducted to investigate the effects of cyclic mechanical strain on primary cultured myofibroblasts seeded onto three-dimensional polymeric scaffolds, and to determine the optimal mechanical treatment time required to produce artificial smooth muscle. The cells were primary cultured from rabbit esophageal smooth muscle layer, and a self-designed stretching chamber was used to modulate the cells on porous polyurethane (PU) scaffolds with 10% strain at a frequency of 1 Hz. The applied cyclic strain induced cellular alignment. In particular, cellular alignment perpendicular to the direction of strain was generated in the condition strained over 18 h. In terms of proliferation, the strained groups differed significantly from the statically cultured group, but no difference was observed between groups that were subjected to straining for different lengths of time. Quantitative analysis of alpha-smooth muscle actin (SMA) showed that differentiation was significantly promoted at 18 h of strain. Penetration of primary cultured cells into the pores of PU scaffolds was shown after cyclic strain application, especially in 18 and 24 h of strain. Consequently, it is expected that myofibroblast/scaffold hybrids, cyclically strained in the defined time course, could be practically applied to organize functional smooth muscle tissues having consistent cell alignment and up-regulated SMA.
Collapse
Affiliation(s)
- Jae Min Cha
- Department of Medical Engineering, Yonsei University College of Medicine, Seoul, Korea
| | | | | | | |
Collapse
|
26
|
Atance J, Yost MJ, Carver W. Influence of the extracellular matrix on the regulation of cardiac fibroblast behavior by mechanical stretch. J Cell Physiol 2004; 200:377-86. [PMID: 15254965 DOI: 10.1002/jcp.20034] [Citation(s) in RCA: 85] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Fibroblasts are responsible in large part for production, organization, and turnover of the extracellular matrix (ECM), thereby regulating the fibrotic content of the heart. Excessive fibrosis, which has been associated with certain forms of hemodynamic overload such as hypertension, is thought to result in increased ventricular chamber stiffness, and eventual heart failure. As such, the role of mechanical stretch in regulating fibroblast activity is crucial to our understanding of healthy and diseased hearts. However, little is known about the effects of alterations in the composition of the ECM in regulating mechanotransduction in cardiac fibroblasts. In order to address this question, rat cardiac fibroblasts were cultured on silastic membranes coated with different ECM substrates, and cyclically stretched for various durations. Experiments were designed to assess the activation of signaling pathways, as well as changes in collagen production, cellular proliferation, and morphology. Mitogen activated protein kinase (MAP kinase) was most rapidly activated, and collagen I expression was most abundant, in cells stretched on randomly organized collagen, and uncoated charged membranes. Regardless of the nature of the ECM substrate, stretched cells decreased proliferation, however, this effect was most marked in cells stretched on randomly organized collagen. Finally, cells stretched on all ECM substrates increased their surface area, but this was observed most significantly in cells adherent to aligned collagen, randomly organized collagen, and uncoated, charged membranes. Taken together, these results suggest cardiac fibroblasts may differentially interpret a mechanical stimulus, in terms of both signal transduction, and specific long-term events such as gene transcription, based on the composition and organization of the ECM.
Collapse
Affiliation(s)
- Joel Atance
- Department of Cell and Developmental Biology and Anatomy, University of South Carolina-School of Medicine, Columbia, South Carolina 29209, USA
| | | | | |
Collapse
|
27
|
Peperzak KA, Gilbert TW, Wang JHC. A multi-station dynamic-culture force monitor system to study cell mechanobiology. Med Eng Phys 2004; 26:355-8. [PMID: 15121062 DOI: 10.1016/j.medengphy.2003.10.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2003] [Revised: 07/07/2003] [Accepted: 10/06/2003] [Indexed: 10/26/2022]
Abstract
To study mechanobiological responses of cells, a dynamic-culture force monitor (D-CFM) system has been developed. The D-CFM extends our previous work to measure contractile forces of a cell-populated collagen gel (CPCG) using a cantilever beam with semiconductor strain gauges. Linear actuators are used in the system and are computer controlled using a LabVIEW interface to independently apply precise motion waveforms to multiple CPCGs. The feasibility tests showed that the new system can detect the differences in force patterns resulting from different motion waveforms imparted to the CPCG. This new system will facilitate the study of the effects of dynamic mechanical loading on cells, remodeling of extracellular matrix, and cell-matrix interactions in vitro.
Collapse
Affiliation(s)
- Katherin A Peperzak
- Mechanobiology Laboratory, Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, E1641 Biomedical Science Tower, 210 Lothrop Street, PO Box 71199, Pittsburgh, PA 15213, USA
| | | | | |
Collapse
|
28
|
Yost MJ, Baicu CF, Stonerock CE, Goodwin RL, Price RL, Davis JM, Evans H, Watson PD, Gore CM, Sweet J, Creech L, Zile MR, Terracio L. A Novel Tubular Scaffold for Cardiovascular Tissue Engineering. ACTA ACUST UNITED AC 2004; 10:273-84. [PMID: 15009952 DOI: 10.1089/107632704322791916] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We have developed a counter rotating cone extrusion device to produce the next generation of three-dimensional collagen scaffold for tissue engineering. The device can produce a continuously varying fibril angle from the lumen to the outside of a 5-mm-diameter collagen tube, similar to the pattern of heart muscle cells in the intact heart. Our scaffold is a novel, oriented, type I collagen, tubular scaffold. We selected collagen because we believe there are important signals from the collagen both geometrically and biochemically that elicit the in vivo -like phenotypic response from the cardiomyocytes. We have shown that cardiomyocytes can be cultured in these tubes and resemble an in vivo phenotype. This new model system will provide important information leading to the design and construction of a functional, biologically based assist device.
Collapse
Affiliation(s)
- Michael J Yost
- Department of Surgery, University of South Carolina School of Medicine, Columbia, South Carolina 29208, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Krishnan L, Weiss JA, Wessman MD, Hoying JB. Design and Application of a Test System for Viscoelastic Characterization of Collagen Gels. ACTA ACUST UNITED AC 2004; 10:241-52. [PMID: 15009949 DOI: 10.1089/107632704322791880] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Characterization and control of the mechanical properties of the extracellular matrix are critical to the interpretation of results of in vitro studies of cultured tissues and cells and for the design of functional engineered constructs. In this work a viscoelastic tensile test system and custom culture chambers were developed and characterized. The system allowed quantification of strain as well as the stresses developed during cyclic viscoelastic material testing. Finite element analysis of the culture chambers indicated that the tensile strains near the actuated ends of the gel were greater than the strains experienced by material in the center of the culture chambers. However, the strain was uniformly distributed over the central substance of the gel, validating the assumption that a homogeneous strain state existed in the central region of the chamber. Viscoelastic testing was performed on collagen gels that were created with three different collagen concentrations. Results demonstrated that there was a significant increase in the dynamic stiffness of the gels with increasing equilibrium strain, collagen concentration, and frequency of applied strain. With increasing strain rate, the phase angle, representing the energy dissipated, dropped initially and then increased at higher rates. Mechanical testing of gels at different time intervals up to 7 days after polymerization demonstrated that the material properties remained stable when appropriate environmental conditions were maintained. The ability to characterize the viscoelastic properties of gels after different periods of culture will allow the quantification of alterations in gel material properties due to changes in cell cytoskeletal organization, cell-matrix interactions, and cellular activity on the matrix. Further, the test device provides a means to apply controlled mechanical loading to growing gel cultures. Finally, the results of this study will provide guidance to the design of further experiments on this substrate.
Collapse
|
30
|
Wang DS, Proffit D, Tsao PS. Mechanotransduction of endothelial oxidative stress induced by cyclic strain. ENDOTHELIUM : JOURNAL OF ENDOTHELIAL CELL RESEARCH 2003; 8:283-91. [PMID: 11824481 DOI: 10.3109/10623320109090806] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Atherosclerotic lesions display a nonuniform distribution throughout the vascular tree. Mechanical forces produced by local alterations in blood flow may play an important role in the localization of atherosclerosis. One such force, cyclic strain, has been hypothesized to promote atherogenesis by inducing oxidative stress in endothelial cells, resulting in enhanced endothelial adhesiveness for monocytes. To investigate the signal transduction systems involved, human aortic endothelial cells were plated on flexible silicone strips that were either non-coated or adsorbed with poly-L-lysine, vitronectin, fibronectin, or collagen I. Cells were then subjected to uniform sinusoidal stretch (10%) for 6 h. Endothelial superoxide anion production was increased in cells exposed to cyclic strain compared to static conditions. Furthermore, endothelial oxidative response to stretch was matrix protein-dependent, whereas cells grown on fibronectin and collagen I produced significantly more superoxide. The oxidative response to cyclic strain was reduced by coincubation with RGD peptides, blocking antibodies to alpha2- and beta-integrins antibodies, as well as inhibitors of protein kinase C. To investigate the effect of oxidative stress on gene transcription, endothelial cells grown on collagen I were transfected with an NFkappaB-sensitive luciferase construct. Cells that underwent cyclic strain displayed a tenfold induction of NFkappaB activation compared to static controls. Strain-induced luciferase activity was blunted by coincubation with RGD peptides or calphostin C. Thus, exposure of endothelial cells to cyclic strain led to integrin activation of a PKC-sensitive pathway that results in increased superoxide anion production and mobilization of NFkappaB.
Collapse
Affiliation(s)
- D S Wang
- Department of Medicine, Stanford University, School of Medicine, CA 94305-5406, USA
| | | | | |
Collapse
|
31
|
Abstract
Extracellular matrix provides a structural, chemical, and mechanical substrate that is essential in cardiac development, growth, and responses to pathophysiological signals. Transmembrane receptors termed integrins provide a dynamic interaction of environmental cues and intracellular events. Integrins orchestrate multiple functions in the intact organism including organogenesis, regulation of gene expression, cell proliferation, differentiation, migration, and death. They are expressed in all cellular components of the cardiovascular system, including the vasculature, blood, cardiac myocytes and nonmuscle cardiac cells. The focus of this review will be on the role of integrins in the myocardium. We will provide background on integrin structure and function, discuss how the expression of integrins is critical to the form and function of the developing and postnatal myocardium, and review the known data on integrins as signaling molecules in the heart. Finally, we will offer insights to the future research directions into this important family of extracellular matrix receptors in the myocardium.
Collapse
Affiliation(s)
- R S Ross
- Department of Physiology, The Cardiovascular Research Laboratories, UCLA School of Medicine, Los Angeles, CA 90095-1751, USA.
| | | |
Collapse
|