1
|
Hanno KI, Metwally NA. The wettability of complete denture base materials constructed by conventional versus digital techniques: an in-vitro study. BMC Oral Health 2024; 24:1081. [PMID: 39272090 PMCID: PMC11395271 DOI: 10.1186/s12903-024-04800-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2024] [Accepted: 08/23/2024] [Indexed: 09/15/2024] Open
Abstract
BACKGROUND Decreased salivary flow can make the patients uncomfortable with their complete dentures and affects the retention of the dentures. Milling and 3D printing have become an alternative to conventional denture construction techniques. The goal of this study was to evaluate the effect of conventional and digital techniques of the complete denture construction on the denture surface wettability with distilled water and saliva substitute before and after thermocycling. METHODS A total of 30 specimens were utilized in the present study. Specimens were divided according to the construction techniques into 3 groups (n = 10 each). Group I: Heat-polymerized polymethylmethacrylate (PMMA) group, group II: Milled group, and group III: 3-dimensional (3D)-printed group. All the specimens were subjected to 2000 cycles of thermal aging in a thermocycler. The wettability of all specimens to water and saliva substitute was measured via a contact angle goniometer (Olympus TGHM, Rame-hart Inc, USA) before and after thermocycling. Descriptive statistical analysis, plots, and the Shapiro-Wilk test were used to verify normality for each variable. One-way ANOVA was used to compare the 3 study groups, while paired samples t-test was used to compare the differences within each group (P < .05). RESULTS The smallest contact angle of drop of water to the denture base specimens before and after thermocycling were recorded in the milled group (53.0 ± 4.77 and 50.27 ± 2.30, respectively), followed by the heat polymerized PMMA group (85.65 ± 4.71 and 65.06 ± 2.27, respectively), and the 3D-printed group (91.34 ± 6.74 and 90.86 ± 8.57, respectively). While the smallest contact angle of drop of saliva substitute to denture base specimens was recorded in the milled group (56.82 ± 2.29 and 34.85 ± 7.51, respectively), followed by the 3D-printed group (72.87 ± 4.83 and 58.14 ± 9.58, respectively) and the heat polymerized PMMA group (83.62 ± 4.12 and 67.82 ± 4.93, respectively). There was statistically significant difference between the groups (P < .05). A significant decline in the average contact angle of drop of saliva has been reported in all groups after thermocycling. The contact angle values differed significantly between saliva substitute and distilled water in both 3D-printed and milled groups after thermocycling (P < .001). CONCLUSIONS The milled denture base material presented the best wettability to water and saliva substitute than the 3D-printed and the heat-polymerized PMMA materials. Saliva substitutes improve the wetting ability of denture base materials manufactured by CAD/CAM compared with water.
Collapse
Affiliation(s)
- Kenda I Hanno
- Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Champolion St, Alexandria, Egypt
| | - Nayrouz Adel Metwally
- Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Champolion St, Alexandria, Egypt.
| |
Collapse
|
2
|
Ellakany P, Madi M, Elwan AH, Alshehri T, Aljubran H, Aly NM. Influence of CAD-CAM manufacturing methods on the accuracy and mechanical properties of implant-supported prostheses: A systematic review. J Prosthodont 2024. [PMID: 39233444 DOI: 10.1111/jopr.13933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Accepted: 08/06/2024] [Indexed: 09/06/2024] Open
Abstract
PURPOSE This systematic review aimed to provide comprehensive insights on the accuracy, fit, and mechanical characteristics of implant-supported computer-aided design and computer-aided manufacturing (CAD-CAM) prostheses, with a focus on milled and 3D-printed approaches. METHODS The research question focused on implant-supported dental prostheses, comparing different manufacturing techniques (conventional, milled, and 3D-printed) to determine the different factors affecting the mechanical properties and fit of the CAD-CAM implant-supported prosthesis. The eligibility criteria encompassed studies involving implant-supported restorations, clear reporting of manufacturing techniques, and English-language publications from the last decade. The search was conducted across three main databases, MEDLINE, Scopus, and Web of Science in September 2023. Publication details, study characteristics, and methodological details of each included study were described. RESULTS Of the initial 1964 articles, 581 met the inclusion criteria, and 104 studies were included in the final qualitative analysis. The majority of studies were conducted in the United States, Turkey, and Brazil. Fourteen studies evaluated accuracy parameters, while four studies focused on mechanical characteristics. The studies revealed variability in mechanical properties and marginal and internal fit, with fabrication methods impacting the structural integrity and stress distribution of the prostheses. CONCLUSIONS The findings suggest that digital manufacturing workflows, both milling and 3D printing, yield acceptable properties for implant-supported restorations with minimal variations in fit and accuracy. Notably, 3D printing and hybrid techniques demonstrate advantages in specific aspects like marginal fit and stress distribution. However, the milled prosthesis provided superior results in flexural strength and fracture resistance compared to conventional methods. Further research is needed to confirm these findings in clinical settings.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Amira H Elwan
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hussain Aljubran
- Department of Periodontics, Penn Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Nourhan M Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
3
|
Al-Fodeh RS, Al-Dwairi ZN, Almasri M, Baba NZ. Mechanical properties of 3D-printed resin denture teeth: An in vitro study. J Prosthodont 2024. [PMID: 39210663 DOI: 10.1111/jopr.13939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 08/17/2024] [Indexed: 09/04/2024] Open
Abstract
PURPOSE The purpose of this study was to compare the wear, fracture strength, and mode of failure of various brands of 3D-printed resin denture teeth with prefabricated acrylic resin. Additionally, the study aimed to analyze the different modes of failure exhibited by these teeth. MATERIALS AND METHODS The study utilized 90 3D-printed and 30 prefabricated, 3D-printed resin teeth from three brands: L = Optiprint Lumina, A = ASIGA DentaTooth, P = Power resins, along with prefabricated acrylic teeth from M = Major Super Lux. Each of the 30 samples per main group was divided into two subgroups: The first subgroup samples (M1, A1, L1, P1) were subjected to thermal cycling and mechanical loading; M2, A2, L2, and P2 were not aged and tested directly. A scan of a prefabricated acrylic tooth was taken using an intraoral scanner, and then the STL file was printed using an Asiga 3Dprinter. The specimens underwent aging to simulate 5 years of clinical use with 10,000 thermal cycles and 1,200,000 dynamic load cycles on a chewing simulator. Surface roughness parameters (Rz, Ra, Rq) were measured using a 3D Optical Profilometer, fracture resistance was assessed using a universal testing machine, and SEM analysis was performed to observe failure modes. Statistical analysis using T-test, one-way analysis, and two-way analysis processed by the Statistical Package for Social Sciences (SPSS) software version 23.0 (SPSS: Inc., Chicago, IL, USA) was done with a level of significance set at <0.05. RESULTS The results showed that the difference in surface roughness parameters (Rz, Ra, Rq) before and after aging for Group M, Group A, Group L, and Group P was statistically significant (p < 0.05). Two-way ANOVA for wear resistance between aging and groups on dependent variable Rz (p = 0.002), Ra (p = 0.001), Rq (p = 0.001) were significant. Multiple comparisons for surface roughness parameters showed Group A and Group L were lower than Group P and Group M (p < 0.05). For fracture strength, One-way ANOVA showed a significant difference between groups for fracture strength either without or after the aging procedure (p < 0.05). Multiple comparisons for fracture strength without aging showed no significant difference between Group M, Group A, and Group L (p > 0.05). After the aging procedure fracture strength for Group M was higher than Group A, Group L, and Group P (p < 0.05). CONCLUSION 3D-printed resin teeth showed a greater and comparable wear resistance to prefabricated acrylic teeth. Fracture strength was comparable between prefabricated acrylic teeth and 3D-printed resin (Asiga and Lumina) before aging, but after aging 3D-printed resin teeth showed less fracture strength.
Collapse
Affiliation(s)
- Rami S Al-Fodeh
- Department of Prosthodontics, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Ziad N Al-Dwairi
- Department of Prosthodontics, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
- Dean, Faculty of Dentistry, The Hashemite University, Zarqa, Jordan
| | - Mahmoud Almasri
- Department of Prosthodontics, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan
| | - Nadim Z Baba
- Advanced Specialty Education Program in Implant Dentistry, Loma Linda University, School of Dentistry, California, USA
| |
Collapse
|
4
|
Lins LBC, Leão RDS, Pellizzer EP, Vasconcelos BCDE, de Moraes SLD. Effect of three-dimensional print angle on integrity of interim crowns: A systematic review. J Prosthet Dent 2024:S0022-3913(24)00504-3. [PMID: 39181773 DOI: 10.1016/j.prosdent.2024.07.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 07/18/2024] [Accepted: 07/19/2024] [Indexed: 08/27/2024]
Abstract
STATEMENT OF PROBLEM Three-dimensional printing is a rapid and cost-effective method that eliminates material waste during the manufacture of indirect restorations. Parameters such as print angle significantly affect the physical properties of the printed material. Several manufacturers suggest using an angle of 45 degrees to perform printing; however, different angles have been used, and the optimum parameters are unclear. PURPOSE The purpose of this systematic review was to compare the 45-degree print angle with other protocols and evaluate the effect of print angle on the physical and mechanical material properties. MATERIAL AND METHODS Two researchers independently searched for relevant studies published up to June 2023 in the PubMed/MEDLINE, Scopus, Web of Science, and Lilacs electronic databases. The population, intervention, comparison, outcome (PICO) question was: "Does the 45-degree print angle promote better physical characteristics for 3-dimensionally printed interim crowns?" Studies that compared the properties of the different print angles of interim crowns were analyzed. RESULTS Ten in vitro studies were selected for qualitative analysis. When evaluating marginal and internal fits, most studies selected the 45-degree angle, resulting in less discrepancy. The results of flexural strength analysis showed a high level of heterogeneity. The 0-degree print angle yielded better results in 3 studies, followed by the 90-degree print angle in 2 studies. The 45-degree angle yielded the highest fracture resistance value in 1 study and similar results to those of the control group (milled PMMA) in another study. CONCLUSIONS The marginal and internal adaptation and resistance to flexure of printed interim crowns are satisfactory when a 45-degree print angle is used.
Collapse
Affiliation(s)
- Laura Buarque Caminha Lins
- Master's student, Division of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Brazil
| | - Rafaella de Souza Leão
- Adjunct Professor, Division of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Brazil.
| | - Eduardo Piza Pellizzer
- Associate Professor, Department of Oral and Maxillo facial Surgery, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Brazil
| | | | - Sandra Lúcia Dantas de Moraes
- Associate Professor, Division of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Brazil
| |
Collapse
|
5
|
Bassenheim D, Rist K, Moszner N, Catel Y, Liska R, Knaack P. Color-Stable Formulations for 3D-Photoprintable Dental Materials. Polymers (Basel) 2024; 16:2323. [PMID: 39204542 PMCID: PMC11359577 DOI: 10.3390/polym16162323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 08/03/2024] [Accepted: 08/13/2024] [Indexed: 09/04/2024] Open
Abstract
Color stability is crucial for dental materials to ensure they perfectly match a patient's tooth color. This is particularly challenging in photoresist-based additive manufacturing. Although some studies have addressed this issue, the exact causes of discoloration and ways to minimize it remain unclear. In this study, the intrinsic causes of discoloration in materials intended for 3D printing are investigated by examining thin-film samples (1200 µm) of various compositions, which are stored under different conditions. The samples are evaluated by measuring the UV-Vis absorption spectra at regular intervals to monitor changes. The findings reveal that both the composition of the formulations and the storage conditions significantly influence the discoloration behavior. Furthermore, methods have been developed to reduce or completely prevent discoloration. The use of photoinitiators with sterically demanding benzoyl moieties, as well as the addition of stabilizers, effectively decreases the intensity of emerging discoloration. Furthermore, incorporating the oxidizing agent cumene hydroperoxide (CHP) results in materials that maintain color stability.
Collapse
Affiliation(s)
- David Bassenheim
- Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9/163 MC, A-1060 Vienna, Austria
| | - Kai Rist
- Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein (Y.C.)
| | - Norbert Moszner
- Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein (Y.C.)
| | - Yohann Catel
- Ivoclar Vivadent AG, Bendererstrasse 2, FL-9494 Schaan, Liechtenstein (Y.C.)
| | - Robert Liska
- Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9/163 MC, A-1060 Vienna, Austria
| | - Patrick Knaack
- Institute of Applied Synthetic Chemistry, Vienna University of Technology, Getreidemarkt 9/163 MC, A-1060 Vienna, Austria
| |
Collapse
|
6
|
Korkes A, Jomaa J, Kavouris A, Lalani T, King P, Lee S, Li H, Li A, Khuu W, Law KHJ, Abduo J. Seating accuracy of removable partial denture frameworks fabricated by different digital workflows in comparison to conventional workflow. J Prosthodont 2024. [PMID: 39118292 DOI: 10.1111/jopr.13923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 07/28/2024] [Indexed: 08/10/2024] Open
Abstract
PURPOSE To evaluate the seating accuracy of removable partial denture (RPD) frameworks fabricated by two digital workflows involving selective laser melting (SLM) in comparison to the conventional workflow. MATERIALS AND METHODS A Kennedy class III modification 1 partially edentulous mandibular arch was used as a master model. Three RPD framework groups were included: (1) a conventional workflow group with conventional impression and casting (CC), (2) a partial digital workflow group with conventional impression and digital fabrication (CD), and (3) a complete digital workflow group with digital impression and digital fabrication (DD). A total of 10 frameworks were produced for each group. The marginal gaps at the occlusal rests, retention arms, and reciprocating arms were measured by a traveling microscope. The data were analyzed with the one-way analysis of variance test. RESULTS At the framework level, the most superior fit was observed for the CD group (79.5 µm) followed by DD (85.3 µm) and CC (114.2 µm) groups. The CD and DD groups were significantly superior to CC (p < 0.001). This fit pattern was consistent for the retention and reciprocating arms, while the occlusal rest fit was similar among all the groups. CONCLUSIONS The SLM frameworks had a promising seating accuracy in comparison to conventional frameworks. The type of impression, conventional or digital, did not affect the accuracy of SLM frameworks. The differences observed in the present study are likely to be of minimal clinical significance.
Collapse
Affiliation(s)
- Andrea Korkes
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Janine Jomaa
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Anastasios Kavouris
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Tahyr Lalani
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Phillip King
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Samantha Lee
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Hongyi Li
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Aixi Li
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Wilson Khuu
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Ka Ho Jesper Law
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Jaafar Abduo
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| |
Collapse
|
7
|
Silva SEGD, Silva NRD, Santos JVDN, Moreira FGDG, Özcan M, Souza RODAE. Accuracy, adaptation and margin quality of monolithic zirconia crowns fabricated by 3D printing versus subtractive manufacturing technique: A systematic review and meta-analysis of in vitro studies. J Dent 2024; 147:105089. [PMID: 38772449 DOI: 10.1016/j.jdent.2024.105089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2024] [Revised: 04/28/2024] [Accepted: 05/18/2024] [Indexed: 05/23/2024] Open
Abstract
OBJECTIVE The purpose of this systematic review and meta-analysis was to evaluate the accuracy (trueness and precision), marginal and internal adaptation, and margin quality of zirconia crowns made by additive manufacturing compared to subtractive manufacturing technology. METHODS The investigation adhered to the PRISMA-ScR guidelines for systematic reviews and was registered at the Prospero database (n°CRD42023452927). Four electronic databases, including PubMed, Scopus, Embase, and Web of Science and manual search was conducted to find relevant studies published until September 2023. In vitro studies that assessed the trueness and precision, marginal and internal adaptation, and margin quality of printed crowns compared to milled ones were included. Studies on crowns over implants, pontics, temporary restorations, laminates, or exclusively experimental materials were excluded. RESULTS A total of 9 studies were included in the descriptive reporting and 7 for meta-analysis. The global meta-analysis of the trueness (P<0.74,I2=90 %) and the margin quality (P<0.61,I2=0 %) indicated no significant difference between the root mean square of printed and milled zirconia crowns. The subgroup analysis for the printing system showed a significant effect (P<0.01). The meta-analysis of the crown areas indicated no significant difference in most of the areas, except for the marginal (favoring milled crowns) and axial (favoring printed crowns) areas. For precision and adaptation, both methods showed a clinically acceptable level. CONCLUSIONS Additive manufacturing technology produces crowns with trueness and margin quality comparable to subtractive manufacturing. Both techniques have demonstrated the ability to produce crowns with precision levels, internal discrepancy, and marginal fit within clinically acceptable limits. CLINICAL SIGNIFICANCE 3D printing emerges as a promising and potentially applicable alternative method for manufacturing zirconia crowns, as it shows trueness and margin quality comparable to restorations produced by the subtractive method.
Collapse
Affiliation(s)
- Sarah Emille Gomes da Silva
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, CEP 59056-000, Brazil
| | - Nathalia Ramos da Silva
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, CEP 59056-000, Brazil
| | - João Vitor do Nascimento Santos
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, CEP 59056-000, Brazil
| | - Fernanda Gurgel de Gois Moreira
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, CEP 59056-000, Brazil
| | - Mutlu Özcan
- University of Zurich, Clinic for Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, Zentrum für Zahnmedizin, Plattenstrasse, 11, 8032 Zurich, Switzerland
| | - Rodrigo Othávio de Assunção E Souza
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787, Lagoa Nova, Natal, RN, CEP 59056-000, Brazil.
| |
Collapse
|
8
|
Yeslam HE, Freifrau von Maltzahn N, Nassar HM. Revolutionizing CAD/CAM-based restorative dental processes and materials with artificial intelligence: a concise narrative review. PeerJ 2024; 12:e17793. [PMID: 39040936 PMCID: PMC11262301 DOI: 10.7717/peerj.17793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 07/01/2024] [Indexed: 07/24/2024] Open
Abstract
Artificial intelligence (AI) is increasingly prevalent in biomedical and industrial development, capturing the interest of dental professionals and patients. Its potential to improve the accuracy and speed of dental procedures is set to revolutionize dental care. The use of AI in computer-aided design/computer-aided manufacturing (CAD/CAM) within the restorative dental and material science fields offers numerous benefits, providing a new dimension to these practices. This study aims to provide a concise overview of the implementation of AI-powered technologies in CAD/CAM restorative dental procedures and materials. A comprehensive literature search was conducted using keywords from 2000 to 2023 to obtain pertinent information. This method was implemented to guarantee a thorough investigation of the subject matter. Keywords included; "Artificial Intelligence", "Machine Learning", "Neural Networks", "Virtual Reality", "Digital Dentistry", "CAD/CAM", and "Restorative Dentistry". Artificial intelligence in digital restorative dentistry has proven to be highly beneficial in various dental CAD/CAM applications. It helps in automating and incorporating esthetic factors, occlusal schemes, and previous practitioners' CAD choices in fabricating dental restorations. AI can also predict the debonding risk of CAD/CAM restorations and the compositional effects on the mechanical properties of its materials. Continuous enhancements are being made to overcome its limitations and open new possibilities for future developments in this field.
Collapse
Affiliation(s)
- Hanin E. Yeslam
- Department of Restorative Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | | | - Hani M. Nassar
- Department of Restorative Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
9
|
Lee B, Hwang J, Lim JH, Kim JE, Shim JS, Shin Y. Three-axis load analysis of high-speed handpiece on dental training teeth and computer-aided design/computer-aided manufacturing blocks. J Mech Behav Biomed Mater 2024; 155:106552. [PMID: 38701678 DOI: 10.1016/j.jmbbm.2024.106552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 04/04/2024] [Accepted: 04/11/2024] [Indexed: 05/05/2024]
Abstract
This study aimed to evaluate and compare the mechanical properties of dental training teeth with subtractive and additive computer-aided design/computer-aided manufacturing (CAD/CAM) materials used to fabricate dental simulation models. Therefore, the three-axis load generated during cutting movements, including drilling and milling performed using a dental handpiece, was measured and compared. The samples were cut vertically downward by 1.5 mm, horizontally by 6 mm, and vertically upward at a constant speed (1 mm/s), while the rotational speed of the bur was maintained at 200,000 rotations per minute. A three-axis load cell was used to measure the X-, Y-, and Z-axis loads on the specimen. The median value of the X-, Y-, and Z-axis measurements and the resultant load during the vertical-downward, horizontal, and vertical-upward movements were compared using a one-way analysis of variance and Tukey's post hoc test. For vertical downward movement, the drilling force of the dental training teeth was lower than that of Vita Enamic® and similar to that of Lava™ Ultimate. In contrast to subtractive CAD/CAM blocks, the drilling force of the dental training teeth was higher than that of 3D-printed resin blocks. Regarding horizontal movement, the milling force of dental training teeth was lower than that of Vita Enamic®. In contrast, the milling force of Nissin was similar to that of Lava™ Ultimate, while that of Frasaco was lower. Furthermore, compared to additive CAD/CAM blocks, the milling force of the dental training teeth was higher than that of 3D-printed resin blocks. Regarding vertical upward movement, the resultant loads of dental training teeth was lower than that of Vita Enamic®. Similarly, the resultant load of Nissin was similar to that of Lava™ Ultimate, while that of Frasaco was lower. Additionally, compared to additive CAD/CAM blocks, the resultant loads of the dental training teeth were similar to those of the 3D-printed resin blocks.
Collapse
Affiliation(s)
- Bora Lee
- Department of Dental Education, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Juyeon Hwang
- Department of Conservative Dentistry, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Jung-Hwa Lim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - June-Sung Shim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Yooseok Shin
- Department of Conservative Dentistry, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
10
|
Pandey R, Kamble R, Kanani H. Revolutionizing Smiles: Advancing Orthodontics Through Digital Innovation. Cureus 2024; 16:e64086. [PMID: 39114257 PMCID: PMC11305434 DOI: 10.7759/cureus.64086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Accepted: 07/08/2024] [Indexed: 08/10/2024] Open
Abstract
Orthodontics is undergoing a digital revolution, transforming traditional techniques with modern technology. This evolution is driven by the need for precise diagnosis and treatment planning. Digital platforms, including digital radiography and cone beam computed tomography (CBCT), are replacing conventional methods, enhancing documentation, analysis, and appliance production. Three-dimensional imaging enables customized treatment plans and appliance design using computer-aided design and computer-aided manufacture (CAD/CAM). Integration of digital models and software facilitates treatment simulation and patient communication. Digital videography enhances diagnostic capabilities. Embracing digital processes is essential for improved patient care and practice efficiency in orthodontics. This review article on digital orthodontics aims to provide a comprehensive overview and critical analysis of the current advancements, technologies, applications, benefits, and challenges in the field of orthodontics utilizing digital tools and technologies.
Collapse
Affiliation(s)
- Ruchika Pandey
- Orthodontics and Dentofacial Orthopedics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Ranjit Kamble
- Orthodontics and Dentofacial Orthopedics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Harikishan Kanani
- Pediatric Dentistry, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| |
Collapse
|
11
|
Chander NG, Gopi A. Trends and future perspectives of 3D printing in prosthodontics. Med J Armed Forces India 2024; 80:399-403. [PMID: 39071750 PMCID: PMC11280134 DOI: 10.1016/j.mjafi.2024.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 05/09/2024] [Indexed: 07/30/2024] Open
Abstract
The three-dimensional (3D) printing technology has led to transformative shift in prosthodontics. This review summarizes the evolution, processing techniques, materials, integration of digital plan, challenges, clinical applications and future directions of 3D printing in prosthodontics. It appraises from the launch of 3D printing to its current applications in prosthodontics. The convergence of printing technology with digital dentistry has facilitated the creation of accurate, customized prostheses, redefining treatment planning, design, and manufacturing processes. The progression of this technology is from generating models to prosthesis like-fixed dental prosthesis (FDP), implants, and splints. Additionally, it exhibits more wide capabilities. The exploration of materials for 3D printing provides various options like polymers, ceramics, metals, and hybrids, each with distinctive properties that are applicable to different clinical scenarios. The combination of 3D-printing technology and digital workflow simplifies the processes of data transfer, computer-aided design (CAD) design to fabrication, decreasing errors and chairside time. The clinical benefits include enhanced accuracy, comfort, conservative lab procedures, and economics. Challenges in the technology involve significant aspects like initial investment, material availability, and skill requirements. Future trends emphasize on research for improved materials, bioprinting integration, artificial intelligence (AI) application, regularization efforts to ensure safe and common use of the technology. 3D printing offers promise in prosthodontics, addressing challenges through research. The material improvements will promote its broader adoption and revolutionize the future of dental rehabilitation.
Collapse
Affiliation(s)
| | - Anup Gopi
- Associate Professor, Department of Dental Surgery & Instructor (Prosthodontics), Armed Forces Medical College, Pune, India
| |
Collapse
|
12
|
Mani G, Porter D, Collins S, Schatz T, Ornberg A, Shulfer R. A review on manufacturing processes of cobalt-chromium alloy implants and its impact on corrosion resistance and biocompatibility. J Biomed Mater Res B Appl Biomater 2024; 112:e35431. [PMID: 38817036 DOI: 10.1002/jbm.b.35431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 03/23/2024] [Accepted: 05/13/2024] [Indexed: 06/01/2024]
Abstract
Cobalt-Chromium (CoCr) alloys are currently used for various cardiovascular, orthopedic, fracture fixation, and dental implants. A variety of processes such as casting, forging, wrought processing, hot isostatic pressing, metal injection molding, milling, selective laser melting, and electron beam melting are used in the manufacture of CoCr alloy implants. The microstructure and precipitates (carbides, nitrides, carbonitrides, and intermetallic compounds) formed within the alloy are primarily determined by the type of manufacturing process employed. Although the effects of microstructure and precipitates on the physical and mechanical properties of CoCr alloys are well reviewed and documented in the literature, the effects on corrosion resistance and biocompatibility are not comprehensively reviewed. This article reviews the various processes used to manufacture CoCr alloy implants and discusses the effects of manufacturing processes on corrosion resistance and biocompatibility. This review concludes that the microstructure and precipitates formed in the alloy are unique to the manufacturing process employed and have a significant impact on the corrosion resistance and biocompatibility of CoCr alloys. Additionally, a historical and scientific overview of corrosion and biocompatibility for metallic implants is included in this review. Specifically, the failure of CoCr alloys when used in metal-on-metal bearing surfaces of total hip replacements is highlighted. It is recommended that the type of implant/application (orthopedic, dental, cardiovascular, etc.) should be the first and foremost factor to be considered when selecting biomaterials for medical device development.
Collapse
Affiliation(s)
- Gopinath Mani
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Deanna Porter
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Shell Collins
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Tim Schatz
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Andreas Ornberg
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| | - Robert Shulfer
- Global Biocompatibility and Science & Technology Organization, Abbott, St. Paul, Minnesota, USA
| |
Collapse
|
13
|
Han JY, Shin JH, Shim JS, Kim RJY. Effects of dentin bonding agents and silanization on bond strength between 3D printed resin and composite resin. Dent Mater J 2024; 43:400-406. [PMID: 38719585 DOI: 10.4012/dmj.2023-181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2024]
Abstract
This study aimed to evaluate the effects of dentin bonding agents and silanization on the bond strength between 3D printed resin and composite resin and compare it with a conventional composite resin. 3D printed resin cylinders (PCB) and composite resin substrates (Z250) were prepared and divided into eight subgroups based on the bonding agents used (n=12). The shear bond strength was measured using a universal testing machine, and the failure modes were evaluated. The bond strength was found to vary significantly among the bonding agents and substrate types. Silane application did not significantly improve the bond strength. Among the bonding agents, the universal adhesives exhibited the highest bond strengths for both substrates. Compared to PCB, Z250 demonstrated stronger bonds and exhibited more cohesive failures. Further research is needed to optimize the surface treatments and resin formulations for enhanced bond strength and durability between 3D printed and composite resins.
Collapse
Affiliation(s)
- Jae-Yeon Han
- Department of Conservative Dentistry, Korea University Medical Center Guro Hospital
| | - Joo-Hee Shin
- Department of Conservative Dentistry, Korea University Medical Center Guro Hospital
| | - Ji-Suk Shim
- Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Guro Hospital
| | - Ryan Jin Young Kim
- Department of Dental Science, Dental Research Institute, School of Dentistry, Seoul National University
| |
Collapse
|
14
|
Echhpal UR, Ahmed N, Kiran R. In Vitro Analysis of the Accuracy of the Use of Waste Zirconia Dust Compared With Optical Scanning Spray on Implant Abutment Models in Extraoral Scanning Protocol. Cureus 2024; 16:e61633. [PMID: 38966468 PMCID: PMC11223720 DOI: 10.7759/cureus.61633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 06/03/2024] [Indexed: 07/06/2024] Open
Abstract
Introduction The evolution of computer-aided design/computer-aided manufacturing (CAD/CAM) systems has heightened the significance of digital models in dentistry, particularly for fabricating prostheses like inlays, crowns, and bridges. While digital dentistry offers enhanced speed and precision, the initial investment in intraoral scanners may pose a barrier for some clinicians. Extraoral or lab scanners, however, offer a viable alternative, reducing laboratory time and providing accurate prostheses fit, though challenges such as reflective surfaces and availability of scanning sprays persist, impacting scanning quality and operator technique. Optical scanning using laboratory scanners is a routine practice in today's age of digital dentistry. Often these require powder opacification to record fine details. There are numbered studies on the accuracy of scanning sprays. Materials and methods Ten casts, poured with type 4 dental stone (Elite Rock, Zhermack, Italy) with single implants, were used for the purpose of this study. Each cast was scanned by two different operators, using both mediums. It was scanned using an extraoral scanner (E4, 3Shape, Copenhagen, Denmark). Operator A used easy scan (Alphadent, Korea), followed by zirconia dust (Upcera, Guangdong, China), whereas operator B used zirconia dust first. Digital models within each group were superimposed individually to measure precision. Results Easy scan operator 1 and zirconia dust operator 1 differ by 0.16000 (p = 0.0802). In scenario 2, easy scan operator 2 and zirconia dust operator 2 differ by 0.21900 (p = 0.0212) . Operator type significantly affects performance, emphasizing the need to account for operator variability in relevant contexts. The trueness values obtained for zirconia dust and easy scan among both operators were statistically insignificant. Conclusion Zirconia dust can be reliably used for extraoral scanning of abutments in place of optical scanning sprays.
Collapse
Affiliation(s)
| | - Nabeel Ahmed
- Prosthodontics, Saveetha Dental College, Chennai, IND
| | - Ram Kiran
- Prosthodontics, Saveetha Dental College, Chennai, IND
| |
Collapse
|
15
|
Mosaddad SA, Peláez J, Panadero RA, Ghodsi S, Akhlaghian M, Suárez MJ. Do 3D-printed and milled tooth-supported complete monolithic zirconia crowns differ in accuracy and fit? A systematic review and meta-analysis of in vitro studies. J Prosthet Dent 2024:S0022-3913(24)00283-X. [PMID: 38772783 DOI: 10.1016/j.prosdent.2024.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 04/03/2024] [Accepted: 04/04/2024] [Indexed: 05/23/2024]
Abstract
STATEMENT OF PROBLEM Additive (3-dimensional printing) and subtractive (milling) methods are digital approaches to fabricating zirconia restorations. Comparisons of their resultant fabrication accuracy and restoration fit are lacking. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the accuracy and fit of monolithic zirconia crowns fabricated by 3-dimensional printing and milling. MATERIAL AND METHODS The PubMed (Medline), Scopus, Embase, Web of Science, Cochrane Library, and Google Scholar databases were searched up to August 2023. Eligible records were included, and the standardized mean difference (SMD) analyzed 4 outcomes: marginal fit, intaglio fit, trueness, and precision. Publication bias was analyzed with Trim-and-fill, the Egger regression test, and Begg funnel plot. Methodological quality was rated using the QUIN tool. RESULTS A total of 15 publications were found eligible out of the initial 6539 records. The 3-dimensional printing group demonstrated a lower marginal fit (SMD=1.46, 95% CI=[0.67, 2.26], P<.001; I2=83%, P<.001) and trueness (SMD=0.69, 95% CI=[0.20, 1.18], P=.006; I2=88%, P<.001) and a significantly higher precision (SMD=-2.19, 95% CI=[-2.90, -1.48], P<.001; I2=56%, P=.045). The intaglio fit did not differ significantly across the study groups (SMD=0.77, 95% CI=[-0.22, 1.77], P=.127; I2=87%, P<.001). CONCLUSIONS Given the high degree of heterogeneity, it can be cautiously concluded that while 3-dimensional printing led to greater precision, the outcomes of the 2 accuracy and adaptation parameters most crucial to the longevity of the restorations-trueness and marginal fit-showed the superiority of the milling technique.
Collapse
Affiliation(s)
- Seyed Ali Mosaddad
- Researcher, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain; and Adjunct Faculty Member, Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
| | - Jesús Peláez
- Adjunct Professor, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain.
| | - Rubén Agustín Panadero
- Professor, Department of Stomatology, Faculty of Medicine and Dentistry, Valencia University, Valencia, Spain
| | - Safoura Ghodsi
- Associate Professor, Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran
| | - Marzieh Akhlaghian
- Assistant Professor, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - María J Suárez
- Professor, Department of Conservative Dentistry and Bucofacial Prosthesis, Faculty of Odontology, Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
16
|
Vohra F, Alsaif R, Khan R, Bukhari IA. Comparison of De-Torque and Failure Load Evaluation of Selective-Laser-Sintered CoCr, CAD-CAM ZrO, and Machined Implant Abutment/Restoration. Bioengineering (Basel) 2024; 11:448. [PMID: 38790315 PMCID: PMC11118100 DOI: 10.3390/bioengineering11050448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 04/16/2024] [Accepted: 04/18/2024] [Indexed: 05/26/2024] Open
Abstract
AIM This study aimed to compare the torque loss, fracture load, compressive strength, and failure types of selective-laser-sintered cobalt chromium (SLM-Co-Cr), computer-aided design and computer-aided manufacturing zirconium oxide (CAD-CAM-ZrO), and machined titanium (Ti) implant abutments. METHODS Thirty endosseous dental implants were vertically embedded with machined Ti (control group), CAD-CAM-ZrO, and SLM-Co-Cr abutments. Abutment fabrication involved CAD-CAM milling and SLM technology. The de-torque assessment included preload reverse torque values (RTVs), cyclic loading, and post-RTVs using a customized protocol. Fracture load assessment employed ISO-14801 standards, and statistical analysis was conducted using ANOVA and Tukey Post hoc tests (p < 0.05). RESULTS In pre-load RTVs, SLM-Co-Cr showed the lowest mean torque loss (24.30 ± 2.13), followed by machined Ti (27.33 ± 2.74) and CAD-CAM-ZrO (22.07 ± 2.20). Post-load RTVs decreased for all groups. Fracture load and compressive strength were highest for SLM-Co-Cr, with significant differences among groups (p < 0.001). Fracture types included abutment failures in SLM-Co-Cr and machined Ti, while CAD-CAM-ZrO exhibited crown separation with deformation. CONCLUSION SLM-Co-Cr-fabricated implant abutments exhibited superior stability and resistance to rotational forces, higher fracture loads, and greater compressive strength compared to CAD-CAM-ZrO and machined Ti.
Collapse
Affiliation(s)
- Fahim Vohra
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 12485-6541, Saudi Arabia;
| | - Rawan Alsaif
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 12485-6541, Saudi Arabia;
| | - Rawaiz Khan
- Engineer Abdullah Bugshan Research Chair for Dental and Oral Rehabilitation, College of Dentistry, King Saud University, Riyadh 12485-6541, Saudi Arabia;
| | - Ishfaq A. Bukhari
- Department of Pharmacology, College of Medicine, King Saud University, Riyadh 12485-6541, Saudi Arabia;
| |
Collapse
|
17
|
Giti R, Farrahi P. Marginal fit of 3-unit implant-supported fixed partial dentures: Influence of pattern fabrication method and repeated porcelain firings. PLoS One 2024; 19:e0301799. [PMID: 38625846 PMCID: PMC11020902 DOI: 10.1371/journal.pone.0301799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 03/23/2024] [Indexed: 04/18/2024] Open
Abstract
BACKGROUND Marginal fit significantly impacts the long-term success of dental restorations. Different pattern fabrication methods, including hand-waxing, milling, or 3D printing, may affect restorations accuracy. The effect of porcelain firing cycles on the marginal fit of metal-ceramic restorations remains controversial, with conflicting findings across studies. PURPOSE The aim was to evaluate the potential effects of multiple porcelain firings (3, 5, 7 cycles) as well as pattern fabrication method (conventional hand-waxing, milling, and 3D printing) on the marginal adaptation of 3-unit implant-supported metal-ceramic fixed partial dentures. It was hypothesized that neither the wax pattern fabrication method nor repeated ceramic firings would significantly affect the marginal adaptation of metal-ceramic crowns. METHODS In this in-vitro study, 30 Cobalt-Chromium alloy frameworks were fabricated based on pattern made through three techniques: conventional hand-waxing, CAD-CAM milling, and CAD-CAM 3D printing (n = 10 per group). Sixteen locations were marked on each abutment to measure the vertical marginal gap at four stages: before porcelain veneering and after 3, 5, and 7 firing cycles. The vertical marginal gap was measured using direct microscopic technique at ×80 magnification. Mean vertical marginal gap values were calculated and two-way ANOVA and Tukey's post hoc tests were used for inter-group comparisons (α = 0.05). RESULTS The 3D printing group showed significantly lower (P<0.001) mean vertical marginal gaps (60-76 μm) compared to the milling (77-115 μm) and conventional hand-waxing (102-110 μm) groups. The milling group exhibited a significant vertical gap increase after 3 firing cycles (P<0.001); while the conventional (P = 0.429) and 3D printing groups (P = 0.501) showed no significant changes after 7 firing cycles. Notably, the vertical marginal gap in all groups remained below the clinically acceptable threshold of 120 μm. CONCLUSION CAD-CAM 3D printing provided superior marginal fit compared to CAD-CAM milling and conventional hand-wax pattern fabrication methods. The impact of porcelain firing on the mean marginal gap was significant only in the milling group. All three fabrication techniques yielded clinically acceptable vertical marginal adaptation after repeated firings. Additive manufacturing holds promise to produce precise implant-supported prostheses.
Collapse
Affiliation(s)
- Rashin Giti
- Oral and Dental Diseases Research Center, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
- Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Pardis Farrahi
- Student Research Committee, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| |
Collapse
|
18
|
Yıldırım M, Aykent F, Özdoğan MS. Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling. J Adv Prosthodont 2024; 16:115-125. [PMID: 38694194 PMCID: PMC11058348 DOI: 10.4047/jap.2024.16.2.115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 02/18/2024] [Accepted: 04/09/2024] [Indexed: 05/04/2024] Open
Abstract
PURPOSE The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.
Collapse
Affiliation(s)
- Mesut Yıldırım
- Duaçınarı Oral and Tooth Health Hospital Bursa, Bursa, Türkiye
| | - Filiz Aykent
- Department of Prosthodontics, Faculty of Dentistry, Ankara Yıldırım Beyazıt University, Ankara, Türkiye
| | - Mahmut Sertaç Özdoğan
- Department of Prosthodontics, Faculty of Dentistry, Ankara Yıldırım Beyazıt University, Ankara, Türkiye
| |
Collapse
|
19
|
Chuchulska B, Dimitrova M, Vlahova A, Hristov I, Tomova Z, Kazakova R. Comparative Analysis of the Mechanical Properties and Biocompatibility between CAD/CAM and Conventional Polymers Applied in Prosthetic Dentistry. Polymers (Basel) 2024; 16:877. [PMID: 38611135 PMCID: PMC11013798 DOI: 10.3390/polym16070877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/14/2024] [Accepted: 03/19/2024] [Indexed: 04/14/2024] Open
Abstract
Modern media often portray CAD/CAM technology as widely utilized in the fabrication of dental prosthetics. This study presents a comparative analysis of the mechanical properties and biocompatibility of CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) polymers and conventional polymers commonly utilized in prosthetic dentistry. With the increasing adoption of CAD/CAM technology in dental laboratories and practices, understanding the differences in material properties is crucial for informed decision-making in prosthodontic treatment planning. Through a narrative review of the literature and empirical data, this study evaluates the mechanical strength, durability, esthetics, and biocompatibility of CAD/CAM polymers in comparison to traditional polymers. Furthermore, it examines the implications of these findings on the clinical outcomes and long-term success of prosthetic restorations. The results provide valuable insights into the advantages and limitations of CAD/CAM polymers, informing clinicians and researchers about their suitability for various dental prosthetic applications. This study underscores the considerable advantages of CAD/CAM polymers over conventional ones in terms of mechanical properties, biocompatibility, and esthetics for prosthetic dentistry. CAD/CAM technology offers improved mechanical strength and durability, potentially enhancing the long-term performance of dental prosthetics, while the biocompatibility of these polymers makes them suitable for a broad patient demographic, reducing the risk of adverse reactions. The practical implications of these findings for dental technicians and dentists are significant, as understanding these material differences enables tailored treatment planning to meet individual patient needs and preferences. Integration of CAD/CAM technology into dental practices can lead to more predictable outcomes and heightened patient satisfaction with prosthetic restorations.
Collapse
Affiliation(s)
- Bozhana Chuchulska
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Ilian Hristov
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Zlatina Tomova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (I.H.); (Z.T.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| |
Collapse
|
20
|
Temizci T, Bozoğulları HN. Effect of thermal cycling on the flexural strength of 3-D printed, CAD/CAM milled and heat-polymerized denture base materials. BMC Oral Health 2024; 24:357. [PMID: 38509542 PMCID: PMC10953149 DOI: 10.1186/s12903-024-04122-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Accepted: 03/07/2024] [Indexed: 03/22/2024] Open
Abstract
BACKGROUND This study compared the impact of thermal cycling on the flexural strength of denture-base materials produced through conventional and digital methods, using both subtractive and additive approaches. METHODS In total, 60 rectangular specimens were fabricated with specific dimensions for flexural strength tests. The dimensions were set according to the International Organization for Standardization (ISO) guideline 20795-1:2013 as 64 × 10 × 3.3 ± 0.2 mm. Specimens from each material group were divided into two subgroups (thermal cycled or nonthermal cycled, n = 10/group). We used distinct methods to produce three different denture-base materials: Ivobase (IB), which is a computer-aided-design/computer-aided-manufacturing-type milled pre-polymerized polymethyl methacrylate resin disc; Formlabs (FL), a 3D-printed denture-base resin; and Meliodent (MD), a conventional heat-polymerized acrylic. Flexural strength tests were performed on half of the samples without a thermal-cycle procedure, and the other half were tested after a thermal cycle. The data were analyzed using a two-way analysis of variance and a post hoc Tukey test (α = 0.05). RESULTS Based on the results of flexural-strength testing, the ranking was as follows: FL > IB > MD. The effect of thermal aging was statistically significant for the FL and IB bases, but not for the MD base. CONCLUSIONS Digitally produced denture bases exhibited superior flexural strength compared with conventionally manufactured bases. Although thermal cycling reduced flexural strength in all groups, the decrease was not statistically significant in the heat-polymerized acrylic group.
Collapse
Affiliation(s)
- Tuğba Temizci
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey.
| | - Hatice Nalan Bozoğulları
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey
| |
Collapse
|
21
|
Temizci T, Bozoğulları HN. Effect of thermocycling on the mechanical properties of permanent composite-based CAD-CAM restorative materials produced by additive and subtractive manufacturing techniques. BMC Oral Health 2024; 24:334. [PMID: 38486195 PMCID: PMC10938812 DOI: 10.1186/s12903-024-04016-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 02/12/2024] [Indexed: 03/18/2024] Open
Abstract
BACKGROUND The aim of the study was to determine and compare the biaxial flexural strength (BFS) and Vickers hardness (VHN) of additive and subtractive manufactured permanent composite-based restorative materials, before and after thermal aging. METHODS A total of 200 specimens were prepared; 100 disc-shaped specimens (diameter 13 × 1.2 mm) for the BFS test and 100 square specimens (14 × 14 × 2 mm) for the VHN test. The specimens were made from various materials: two subtractive composite-based blocks (Cerasmart 270 [CS], Vita Enamic [VE]), two additive composite-based resins used for two different vat polymerization methods (digital light processing [DLP]; Saremco Print Crowntec [SC] and stereolithography [SLA]; Formlabs Permanent Crown Resin [FP]), and one feldspathic glass-matrix ceramic block (Vita Mark II [VM]) as the control group. Specimens of each material were divided into two subgroups: thermal cycled or non-thermal cycled (n = 10). BFS and VHN tests were performed on all groups. Data were analyzed with two-way ANOVA and post hoc Tukey test (α = 0.05). RESULTS The type of restorative material used for the specimen had a statistically significant influence on both BFS and VHN values. However, thermal cycling did not affect the BFS and VHN values. After thermal cycling, the results of the BFS test were ranked from best to worst as follows: CS, FP, SC, VE, then VM. For the VHN values, the order from best to worst was as follows: VM, VE, CS, FP, then SC. CONCLUSIONS 3D printed and milled composite groups showed higher BFS than feldspathic ceramics. When the VHN results were examined, it was seen that the 3D resin groups had the lowest VHN values. Furthermore, it was observed that the thermal cycle had no effect on BFS or VHN.
Collapse
Affiliation(s)
- Tuğba Temizci
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey.
| | - Hatice Nalan Bozoğulları
- Department of Prosthodontics, Faculty of Dentistry, Karamanoğlu Mehmetbey University, Karaman, Turkey
| |
Collapse
|
22
|
Lim B, Kim D, Song JS, Kim S, Kim H, Shin Y. Influence of Post-Curing in Nitrogen-Saturated Condition on the Degree of Conversion and Color Stability of 3D-Printed Resin Crowns. Dent J (Basel) 2024; 12:68. [PMID: 38534292 DOI: 10.3390/dj12030068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 02/19/2024] [Accepted: 03/04/2024] [Indexed: 03/28/2024] Open
Abstract
Post-curing is the process of applying extra light to complete the polymerization process of 3D printing. The mechanical properties of light-cured three-dimensional (3D) printed resin can be improved by decreasing the oxygen concentrations during post-curing, and nitrogen-saturated post-curing has been applied for this purpose. This study aimed to evaluate and compare the color stability of 3D-printed resin crowns that were post-cured in both normal air and nitrogen-saturated conditions. Crowns were fabricated with a 3D printer and post-cured in normal air (control group; air) or nitrogen-saturated conditions (experimental group; nitrogen). The specimens in each group were subdivided into four subgroups, each exposed to different discoloration agents: distilled water, coffee, wine, and curry. Post-immersion color changes were measured using a digital spectrophotometer and analyzed using repeated-measures ANOVA. Fourier transform infrared (FT-IR) spectroscopy evaluated the degree of conversion of resin over immersion times for both post-curing conditions. Upon comparing the effects of post-curing conditions, a significant difference between the control and experimental groups in terms of immersion time in the wine and curry subgroups was found. FT-IR analysis showed a significant difference in the degree of conversion between the air and nitrogen groups from 10 to 300 s. These findings suggest that nitrogen-saturated post-curing can potentially enhance the conversion rate of 3D-printed resin crowns, thereby improving their color stability.
Collapse
Affiliation(s)
- Bohyun Lim
- Department of Conservative Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Republic of Korea
| | - Dohyun Kim
- Department of Conservative Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Republic of Korea
| | - Je Seon Song
- Department of Pediatric Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Republic of Korea
| | - Sunil Kim
- Department of Conservative Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Republic of Korea
| | - Hoon Kim
- Research Institute of Agriculture and Life Sciences, College of Agriculture & Life Sciences, Seoul National University, Seoul 08826, Republic of Korea
| | - Yooseok Shin
- Department of Conservative Dentistry, College of Dentistry, Yonsei University, Seoul 03722, Republic of Korea
| |
Collapse
|
23
|
Kyung KY, Park JM, Heo SJ, Koak JY, Kim SK, Ahn JS, Yi Y. Comparative analysis of flexural strength of 3D printed and milled 4Y-TZP and 3Y-TZP zirconia. J Prosthet Dent 2024; 131:529.e1-529.e9. [PMID: 38212154 DOI: 10.1016/j.prosdent.2023.12.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 12/20/2023] [Accepted: 12/20/2023] [Indexed: 01/13/2024]
Abstract
STATEMENT OF PROBLEM The mechanical properties of 3 dimensionally (3D) printed zirconia have been reported to be comparable with those of milled zirconia, except for the flexural strength. However, most previous studies tested 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), making it necessary to study 3D printed zirconia with 4 mol% yttria content (4Y-TZP). PURPOSE The purpose of this in vitro study was to compare the flexural strength of 3D printed 4Y-TZP with 3Y-TZP materials and milled 4Y-TZP. MATERIAL AND METHODS A total of 80 disk specimens (Ø15×1.5 mm) were fabricated and divided into 4 groups (n=20) using the fabrication method and yttria content: milled 3Y-TZP (Katana HT; Kuraray Noritake), 3D printed 3Y-TZP (TZ-3Y-E; Tosoh), milled 4Y-TZP (Katana STML; Kuraray Noritake), and 3D printed 4Y-TZP (3DMAT; Genoss). The biaxial flexural strength was determined with a piston-on-3-ball test (n=15). The flexural strength of each specimen was measured, and the Weibull modulus (m) and characteristic strength (σ0) were estimated from the fracture load distribution. Two intact and fractured specimens were examined with scanning electron microscopy (SEM). The crystalline phase of the specimens in each group was identified through X-ray diffraction (XRD) analysis (n=5). A 1-way ANOVA was used to compare the flexural strength among different groups. Subsequently, pairwise comparisons were conducted with the Tukey post hoc method (α=.05). RESULTS The flexural strength of 3D printed 4Y-TZP was significantly higher than that of milled 4Y-TZP (P<.001). In contrast, the flexural strength of 3D printed 3Y-TZP was significantly lower than that of milled 3Y-TZP (P<.001). X-ray diffraction (XRD) analysis revealed that the tetragonal phase was the dominant phase in all groups, with the identification of some cubic phase peaks. CONCLUSIONS Three dimensionally printed 4Y-TZP showed significantly higher flexural strength than milled 4Y-TZP and exhibited a clinically acceptable flexural strength exceeding 800 MPa.
Collapse
Affiliation(s)
- Kyu-Young Kyung
- PhD Candidate, Department of Prosthodontics & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Republic of Korea
| | - Ji-Man Park
- Associate Professor, Department of Prosthodontics & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea.
| | - Seong-Joo Heo
- Professor, Department of Prosthodontics & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Jai-Young Koak
- Professor, Department of Prosthodontics & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Seong-Kyun Kim
- Professor, Department of Prosthodontics & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Jin-Soo Ahn
- Professor, Department of Dental Biomaterials Science & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Yuseung Yi
- Assistant Professor, Department of Prosthodontics & Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
24
|
Peskersoy C, Oguzhan A. Evaluation of the Mechanical and Adhesion Characteristics of Indirect Restorations Manufactured with Three-Dimensional Printing. Polymers (Basel) 2024; 16:613. [PMID: 38475296 DOI: 10.3390/polym16050613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 02/18/2024] [Accepted: 02/21/2024] [Indexed: 03/14/2024] Open
Abstract
The aim of this study was to investigate the marginal fit and bond strength characteristics of onlay restorations manufactured by three-dimensional printing (Varseo XS, Bego GmbH, Bremen, Germany) and CAD/CAM (CAMcube, Montreal, QC, Canada) systems. Class II onlay cavities on sixty mandibular molars were prepared in cavities and restored in three separate groups using different fabrication methods. Digital and conventional impressions were taken to design the restorations in the CAD system (DWOS, Straumann GmbH, Freiburg, Germany). To evaluate the marginal fit and void volumes, all specimens were scanned with microcomputed tomography. A microshear test was performed to compare the bond strength of the restorations to the tooth surface. The marginal fit values measured for the 3D-printed and CAD/CAM onlay restorations were found to be at clinically acceptable levels (<120 µm), and no significant difference could be observed between the three different fabrication methods (p > 0.05). According to the microshear test results, the CAD/CAM group had the highest bond strength values before (34.82 MPa) and after (26.87 MPa) thermal cycling (p < 0.05), while the 3D-printed and conventionally produced onlays had similar results (p < 0.05). 3D printing technology is a promising option for indirect restorations; however, the post-production phase is as crucial as the printing and cementation phases.
Collapse
Affiliation(s)
- Cem Peskersoy
- Faculty of Dentistry, Ege University, 35030 Izmir, Turkey
| | | |
Collapse
|
25
|
Sayed ME, Reddy NK, Reddy NR, Mattoo KA, Jad YA, Hakami AJ, Hakami AK, Dighriri AM, Hurubi SY, Hamdi BA, Alshahrani AA, Alsubaiy EF, Alshehri AH, AlNijaiban MA. Evaluation of the Milled and Three-Dimensional Digital Manufacturing, 10-Degree and 20-Degree Preparation Taper, Groove and Box Auxiliary Retentive Features, and Conventional and Resin-Based Provisional Cement Type on the Adhesive Failure Stress of 3 mm Short Provisional Crowns. Med Sci Monit 2024; 30:e943237. [PMID: 38343120 PMCID: PMC10870690 DOI: 10.12659/msm.943237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Accepted: 12/05/2023] [Indexed: 02/15/2024] Open
Abstract
BACKGROUND This study evaluated the effects of milling (CADCAM), 3D printing, preparation taper angles (10-degree and 20-degree), auxiliary retentive features (groove and box), and provisional cement types (conventional and resin-based) on the adhesive failure stress of 3-mm short provisional crowns (PC). The research was motivated by the need to understand how digital dentistry technologies impact the retention and durability of provisional crowns. MATERIAL AND METHODS A total of 160 working models (3D-printed) and PCs [80 milled (CopraTemp)/80 printed (Asiga)] were fabricated from two 10- and 20-degree typodont master models and two 20-degree 3D-printed master models (groove and box), simulating a 3 mm high all-ceramic short PC. After provisional cementation with conventional (Kerr TempBond) and resin-based (ProviTemp) cements, 16 subgroups (n=10 each) underwent thermocycling (10 000 cycles; 5-55°C) and pull-off tests on a universal testing machine. Statistical analysis was performed using one-way ANOVA and post hoc Tukey test. RESULTS Conventional cement failed at lower stress for milled (47.68 to 73.54) and printed (48.40 to 77.91) as compared to resin cement for milled (104.2 to 137.27) and printed (184.85 to 328.84), respectively, with significant differences. Increased taper and groove decreased failure load except for the printed PC/resin cement combination. Use of proximal box preparation increased retention significantly. Except for 20-degree taper cemented with conventional cement, the differences in auxiliary retentive features for milled and printed provisional crowns were statistically significant at P≤0.05. CONCLUSIONS 3D-printed PC, resin-based cement, 10-degree taper, and proximal box preparation were associated with higher retention than milled, conventional cements, 20-degree taper, and vertical groove.
Collapse
Affiliation(s)
- Mohammed E. Sayed
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Nandalur Kulashekar Reddy
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Naveen R. Reddy
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Khurshid A. Mattoo
- Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Yaser Ali Jad
- Intern, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | | | | | | | - Salman Y. Hurubi
- Intern, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Bassam Ali Hamdi
- Intern, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Ahid Amer Alshahrani
- Department of Dental Technology, Applied Medical Science, King Khalid University, Abha, Saudi Arabia
| | - Ebrahim Fihaid Alsubaiy
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Abdullah Hasan Alshehri
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | | |
Collapse
|
26
|
Emam ANM, El-Esawy AA, Alyami MH, Baraka Y, Gad MM, Helal MA. Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases. Dent J (Basel) 2024; 12:32. [PMID: 38392236 PMCID: PMC10888425 DOI: 10.3390/dj12020032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 01/21/2024] [Accepted: 01/25/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND Digital technology has been introduced in prosthodontics, and it has been widely used in denture duplication instead of a conventional denture duplication technique. However, research comparing different denture duplication techniques and how they affect the fitting accuracy of the denture base is scarce. OBJECTIVES The aim was to assess the impact of duplication techniques on the accuracy of the fitting surface of computer-aided design and manufacturing (CAD-CAM) milled, 3D-printed, and injection-molded complete denture bases (CDBs). METHODOLOGY This study involved fabricating a mandibular complete denture base with three marked dimples as reference marks (A, B, and C at the incisive papilla, right molar, and left molar areas) using a conventional compression molded technique. This denture was then scanned to generate a standard tessellation language (STL) file; after that, it was duplicated using three different techniques (milling, 3D printing, and injection molding) and five denture base resin materials-two milled CAD-CAM materials (AvaDent and IvoBase), two 3D-printed materials (NextDent and HARZ Labs), and one injection-molded material (iFlextm). Based on the denture base type, the study divided them into five groups (each with n = 10). An evaluation of duplication accuracy was conducted on the fitting surface of each complete denture base (CDB) using two assessment methods. The first method was a two-dimensional evaluation, which entailed linear measurements of the distances (A-B, A-C, and B-C) between reference points on both the scanned reference mandibular denture and the duplicated dentures. Additionally, a three-dimensional superimposition technique was employed, involving the overlay of the STL files of the dentures onto the reference denture's STL file. The collected data underwent statistical analysis using a one-way analysis of variance and Tukey's pairwise post hoc tests. RESULTS Both evaluation techniques showed significant differences in fitting surface accuracy between the tested CDBs (p ˂ 0.001), as indicated by one-way ANOVA. In addition, the milled CDBs (AvaDent and IvoBase) had significantly higher fitting surface accuracy than the other groups (p ˂ 0.001) and were followed by 3D-printed CDBs (NextDent and HARZ Labs), while the injection-molded (iFlextm) CDBs had the lowest accuracy (p ˂ 0.001). CONCLUSIONS The duplication technique of complete dentures using a CAD-CAM milling system produced superior fitting surface accuracy compared to the 3D-printing and injection-molded techniques.
Collapse
Affiliation(s)
- Abdel-Naser M Emam
- Prosthetic Dental Science Department, Faculty of Dentistry, Najran University, Najran 55461, Saudi Arabia
| | - Ahmed Ayman El-Esawy
- Department of Prosthodontics, Faculty of Dental Medicine, Sina University, El-Arish 45511, Egypt
| | - Mohammed Hamad Alyami
- Prosthetic Dental Science Department, Faculty of Dentistry, Najran University, Najran 55461, Saudi Arabia
| | - Yasser Baraka
- Department of Prosthodontics, Faculty of Dental Medicine, Deraya University, Al-Menia 61111, Egypt
| | - Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia
| | - Mohamed Ahmed Helal
- Department of Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo 11884, Egypt
| |
Collapse
|
27
|
Jang G, Kim SK, Heo SJ, Koak JY. Fit analysis of stereolithography-manufactured three-unit resin prosthesis with different 3D-printing build orientations and layer thicknesses. J Prosthet Dent 2024; 131:301-312. [PMID: 36653209 DOI: 10.1016/j.prosdent.2021.11.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 11/15/2021] [Accepted: 11/15/2021] [Indexed: 01/19/2023]
Abstract
STATEMENT OF PROBLEM Printing conditions can affect the fit of a 3-dimensionally (3D) printed prosthesis. Therefore, it is important to determine the optimal printing conditions for stereolithography (SLA)-manufactured prostheses. PURPOSE The purpose of this study was to analyze the fit according to the build orientations and layer thicknesses in SLA-manufactured 3-unit resin prostheses. MATERIAL AND METHODS SLA 3D printed prostheses were produced in 5 build orientations (0, 30, 45, 60, and 90 degrees) and 2 layer thicknesses (50 and 100 μm). Milled prostheses were fabricated from the same design. The mounted prostheses on the master model were scanned with microcomputed tomography (μCT). Data were processed with the NRecon software program. For quantitative analysis, marginal and internal fits were measured by using the imageJ software program in terms of the following metrics: absolute marginal discrepancy, marginal gap, cervical area, midaxial wall area, line-angle area, and occlusal area. Internal gap volume was also measured with the CTAn software program. For statistical analysis, ANOVA and Tukey HSD tests were used (α=.05). For qualitative analysis, μCT cross-sections were compared among groups, and intaglio surfaces were imaged with a scanning electron microscope. RESULTS A layer thickness of 50 μm with build orientations of 45 and 60 degrees exhibited smaller mean gap values (P<.05) than the other conditions for all measurements except line-angle area and occlusal area. The scanning electron microscope images showed voids on the intaglio surfaces for the 0- and 90-degree groups. CONCLUSIONS For SLA 3D printed resin prostheses, a difference in fit occurred based on the printing conditions, although both 3D printed and milled prostheses showed a clinically acceptable fit. When an SLA 3D printed prosthesis is manufactured under appropriate conditions, a clinically acceptable fit can be obtained.
Collapse
Affiliation(s)
- Gaejun Jang
- Post-Doctor, Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Seong-Kyun Kim
- Professor, Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, Seoul, Republic of Korea.
| | - Seong-Joo Heo
- Professor, Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Jai-Young Koak
- Professor, Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
28
|
Lee Y, Wang S, Yan P, Zhao Y, Liu Y. Effect of storage temperature on the dimensional stability of DLP printed casts. J Prosthet Dent 2024; 131:331.e1-331.e7. [PMID: 37978005 DOI: 10.1016/j.prosdent.2023.10.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/22/2023] [Accepted: 10/23/2023] [Indexed: 11/19/2023]
Abstract
STATEMENT OF PROBLEM Despite studies focusing on the accuracy and dimensional stability of additive manufacturing, research on the impact of storage conditions on these properties of 3-dimensional (3D) printed objects is lacking. PURPOSE The purpose of this in vitro study was to investigate the influence of storage temperature on the dimensional stability of digital light processing (DLP) printed casts and to determine how different locations in printed casts react differently. MATERIAL AND METHODS A completely dentate maxillary typodont model was digitized with a desktop laser scanner. The typodont was subsequently modified with a software program by adding cuboids with a side length of 3 mm on both maxillary central incisors, first molars, and second molars. The file was saved in the standard tessellation language (STL) format. The modified digitized typodont was then processed through the DLP technology printing process with a desktop DLP printer and photopolymerizing resin. The casts were printed 32 times and stored in sealed plastic bags, shielded from light, and subjected to 4 different temperature conditions (-20 °C, 4 °C, 20 °C, and 37 °C, n=8 each). The cuboids on the central incisors were labeled as the P1 group, first molars as the P2 group, and second molars as the P3 group. The distance between the cuboids was measured 5 times, with results recorded immediately after cast production and at 1, 2, 3, 5, 7, 14, and 28 days after. Repeated analysis of variance (ANOVA) and the Tukey honestly significant difference (HSD) test were used to compare the recorded values among the groups (α=.05). RESULTS In the P1 group, the casts stored at -20 °C exhibited the smallest overall size change, with a mean ±standard deviation volume of 99.42 ±0.04% compared with the original casts after 28 days of storage. This was followed by the casts stored at 4 °C, 20 °C, and 37 °C, with remaining volumes of 99.39 ±0.06% (P=.139), 99.14 ±0.08% (P<.001), and 98.96 ±0.03% (P<.001), respectively. For the P2 and P3 groups, casts stored at 4 °C retained the most volume at 99.82 ±0.01%, whereas those stored at -20 °C, 20 °C, and 37 °C underwent greater changes, with remaining volumes of 99.66 ±0.03%, 100.32 ±0.02%, and 100.44 ±0.02%, respectively (P<.001). The P3 group exhibited a similar trend to that of the P2 group, with the casts stored at 4 °C remaining closest to the original dimensions at 99.86 ±0.02%, while casts stored at -20 °C showed 99.73 ±0.03% of the original volume and those stored at 20 °C and 37 °C expanded with volumes of 100.37 ±0.03% and 100.48 ±0.03%, respectively (P<.001). CONCLUSIONS DLP printed casts stored at 4 °C exhibited the greatest overall dimensional stability, followed sequentially by those stored at -20 °C, 20 °C, and 37 °C. Additionally, the study confirmed that the posterior and anterior teeth regions of DLP printed casts respond differently to different storage temperatures.
Collapse
Affiliation(s)
- Yeh Lee
- Master's Candidate and Resident, Department of Prosthodontics , Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Shimin Wang
- Technician, Dental Laboratory, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China, Peking University School and Hospital of Stomatology, Beijing, PR China; and Department of Dental Materials, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Pengtao Yan
- Researcher, Postgraduate Research Program, Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Yijiao Zhao
- Senior Engineer, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Yunsong Liu
- Professor and Dean, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China.
| |
Collapse
|
29
|
Hajjaj MS, Alamoudi RAA, Babeer WA, Rizg WY, Basalah AA, Alzahrani SJ, Yeslam HE. Flexural strength, flexural modulus and microhardness of milled vs. fused deposition modeling printed Zirconia; effect of conventional vs. speed sintering. BMC Oral Health 2024; 24:38. [PMID: 38185744 PMCID: PMC10771678 DOI: 10.1186/s12903-023-03829-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 12/26/2023] [Indexed: 01/09/2024] Open
Abstract
BACKGROUND Various methods can be used for creating zirconia dental restorations, including 3-dimensional (3D) printing and computer-aided design/ computer-aided manufacturing (CAD/CAM) milling. The fused deposition modeling (FDM) printing method for zirconia presents numerous advantages, albeit research on the mechanical properties of these materials and resultant restorations remains scarce. Such developments are undeniably intriguing and warrant further investigation. The objective of the present study was to evaluate the impact of the sintering firing cycle (Conventional vs. Speed sintering) on the flexural strength, flexural modulus, and Vickers Microhardness of milled vs. FDM printed zirconia. METHODS A total of 60 bars (2 × 5 × 27 mm) were fabricated for flexural strength testing, along with 40 discs (12 × 1.5 mm) for Vickers microhardness testing. Half of the specimens underwent conventional sintering, while the other half underwent a speed sintering cycle. The flexural strength and modulus were determined by a three-point bending test in a universal testing machine. The microhardness of the specimens was evaluated using a Vickers microhardness tester. Statistical analysis was performed using a two-way ANOVA test with a post-hoc Tukey test (p < 0.05). RESULTS CAD/CAM milled zirconia had significantly higher flexural strength and modulus than FDM-printed zirconia. The sintering process did not significantly affect the flexural strength or modulus of milled or FDM-printed zirconia. The milled speed sintering group had significantly higher values in the Vickers microhardness test compared to the other groups. CONCLUSIONS The mechanical properties of FDM-printed zirconia specimens were not found to be comparable to those of milled zirconia. Speed sintering cycle may produce milled zirconia restorations with similar flexural strength and modulus to conventional sintering, and even higher Vickers Microhardness values.
Collapse
Affiliation(s)
- Maher S Hajjaj
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
- Advanced Technology Dental Research Laboratory, King Abdulaziz University, P.O. Box 80209, Jeddah, 21589, Saudi Arabia.
| | - Rana A A Alamoudi
- Prosthodontic Master Student, Department of Oral and Maxillofacial Rehabilitation, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Walaa A Babeer
- Department of Oral and Maxillofacial Rehabilitation, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Waleed Y Rizg
- Department of Pharmaceutics, Faculty of Pharmacy, King Abdulaziz University, Jeddah, 21589, Saudi Arabia
- Center of Innovation in Personalized Medicine (CIPM), 3D Bioprinting Unit, King Abdulaziz University, Jeddah, 21589, Saudi Arabia
| | - Ahmad A Basalah
- Mechanical Engineering Department, College of Engineering and Architecture, Umm Al Qura University, Makkah, Saudi Arabia
| | - Saeed J Alzahrani
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Hanin E Yeslam
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
30
|
Lee CG, Jin G, Lim JH, Liu Y, Afrashtehfar KI, Kim JE. Influence of hydrothermal aging on the shear bond strength of 3D printed denture-base resin to different relining materials. J Mech Behav Biomed Mater 2024; 149:106221. [PMID: 37976994 DOI: 10.1016/j.jmbbm.2023.106221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 10/31/2023] [Accepted: 11/03/2023] [Indexed: 11/19/2023]
Abstract
OBJECTIVES This study evaluated the repairability of three-dimensional printed (3DP) denture bases based on different conventional relining materials and aging. MATERIAL AND METHODS The groups for surface characterization (surface-roughness and contact-angle measurements) were divided based on the denture base and surface treatment. Shear bond strength test and failure-mode analysis were conducted by a combination of three variables: denture base, relining materials, and hydrothermal aging (HA). The initial characterization involved quantifying the surface roughness (n = 10) and contact angle (n = 10) of denture base specimens with and without sandblasting (SB) treatment. Four relining materials (Kooliner [K], Vertex Self-Curing [V], Tokuyama Rebase II (Normal) [T], and Ufi Gel Hard [U]) were applied to 3DP, heat-cured (HC), and self-cured (SC) denture-base resin specimens. Shear bond strength (n = 15) and failure-mode analyses (n = 15) were performed before and after HA, along with evaluations of the fractured surfaces (n = 4). Statistical analyses were performed using a two-way analysis of variance (ANOVA) for surface characterization, and a three-way ANOVA was conducted for shear bond strength. RESULTS The surface roughness peaked in HC groups and increased after SB. The 3DP group displayed significantly lower contact angles, which increased after treatment, similar to the surface roughness. The shear bond strength was significantly lower for 3DP and HC denture bases than for SC denture bases, and peaked for U at 10.65 ± 1.88 MPa (mean ± SD). HA decreased the shear bond strength relative to untreated samples. Furthermore, 3DP, HC, and SC mainly showed mixed or cohesive failures with V, T, and U. K, on the other hand, trended toward adhesive failures when bonded with HC and SC. CONCLUSION This study has validated the repairability of 3DP dentures through relining them with common materials used in clinical practice. The repairability of the 3DP denture base was on par with that of conventional materials, but it decreased after aging. Notably, U, which had a postadhesive application, proved to be the most effective material for repairing 3DP dentures.
Collapse
Affiliation(s)
- Chan-Gyu Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Oral Science Research Center, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| | - Gan Jin
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Oral Science Research Center, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| | - Jung-Hwa Lim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| | - Yunqi Liu
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Oral Science Research Center, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| | - Kelvin I Afrashtehfar
- Division of Restorative Dental Sciences, College of Dentistry, Ajman University, University Street, Al Jerf 1, 346 Ajman, United Arab Emirates; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010, Bern, Switzerland; Department of Operative Dentistry, Periodontology and Preventive Dentistry, RWTH Aachen University Hospital, Pauwelsstrasse 30, 52074, Aachen, Germany.
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
31
|
Prakash J, Shenoy M, Alhasmi A, Al Saleh AA, C SG, Shivakumar S. Biocompatibility of 3D-Printed Dental Resins: A Systematic Review. Cureus 2024; 16:e51721. [PMID: 38318586 PMCID: PMC10839546 DOI: 10.7759/cureus.51721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 01/05/2024] [Indexed: 02/07/2024] Open
Abstract
BACKGROUND The biocompatibility of 3D-printed dental resins has become a critical concern in modern dentistry due to the increasing utilization of additive manufacturing (AM) techniques in dental applications. These resins serve as essential materials for fabricating dental prostheses, orthodontic devices, and various dental components. As the clinical adoption of 3D printing in dentistry grows, it is imperative to comprehensively assess the biocompatibility of these materials to ensure patient safety and dental treatment efficacy. This systematic review aimed to evaluate the existing body of literature on the biocompatibility of 3D-printed dental resins, thereby providing valuable insights into the potential biological risks associated with their use. METHODS The search strategy to identify relevant papers was implemented across PubMed/MEDLINE, Scopus, Web of Science, Embase, Cochrane Library, CINAHL, and Google Scholar to identify relevant studies. Study selection was not limited to any particular timeframe of publishing. The revised CONSORT criteria were used to ascertain the authenticity and dependability of the review's outcomes. Comprehensive screening and eligibility assessment processes were conducted to select studies meeting predefined criteria. Biocompatibility-related parameters, including toxicity, mechanical properties, cell viability, and other relevant outcomes, were analyzed across selected studies using a standardized variable extraction protocol. RESULTS A total of 9 studies were included in the systematic review. The findings encompassed various aspects of biocompatibility assessment, including material composition, mechanical properties, cell viability, and cytotoxicity. Some studies revealed significant improvements in flexural strength and cell viability with specific resin formulations, demonstrating their potential for enhanced clinical utility. Conversely, certain resins exhibited cytotoxicity, while others displayed promising biocompatibility profiles. CONCLUSION As per the assessed findings, material composition, post-processing techniques, and manufacturing methods emerged as critical factors influencing biocompatibility outcomes. While some resins exhibited favorable biocompatibility profiles, others raised concerns due to cytotoxicity. These findings emphasize the need for careful consideration when selecting and implementing 3D-printed dental resins, with a focus on materials engineering and comprehensive biocompatibility testing. Further research is warranted to elucidate the long-term biocompatibility and clinical implications of these materials.
Collapse
Affiliation(s)
- Jayant Prakash
- Department of Prosthodontics, Dental Institute, Rajendra Institute of Medical Sciences, Ranchi, IND
| | - Mahesh Shenoy
- Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Medicine and Dentistry, Riyadh Elm University, Riyadh, SAU
| | - Abdulmajeed Alhasmi
- Department of Periodontics, King Salman Hospital, Ministry of Health, Riyadh, SAU
| | | | - Shivakumar G C
- Department of Oral Medicine and Radiology, People's College of Dental Sciences and Research Centre, Bhopal, IND
| | - Sahana Shivakumar
- Department of Public Health Dentistry, People's College of Dental Sciences and Research Centre, Bhopal, IND
| |
Collapse
|
32
|
Ibrahim H, El Kateb M, Morsy N. Effect of modifying occlusal cement spacer on the fit accuracy of digitally manufactured zirconia crowns. J Prosthet Dent 2024; 131:93.e1-93.e6. [PMID: 37867014 DOI: 10.1016/j.prosdent.2023.09.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 09/27/2023] [Accepted: 09/27/2023] [Indexed: 10/24/2023]
Abstract
STATEMENT OF PROBLEM Cement spacer has a crucial influence on the adaptation of fixed restorations. Recently, digitally fabricated zirconia crowns have become more popular, but studies on the effect of occlusal cement spacer on the fit accuracy of digitally designed and milled zirconia crowns are lacking. PURPOSE The purpose of this in vitro study was to investigate the effect of modifying digital occlusal spacer on the marginal and internal fit of digitally manufactured zirconia crowns. MATERIAL AND METHODS A maxillary molar typodont tooth was prepared for a zirconia crown, scanned with the Medit i700 intraoral scanner (IOS), and the standard tessellation language (STL) file was used to produce 3-dimensionally (3D) printed definitive dies assigned to 3 groups (n=12). All dies were scanned with the IOS, and the obtained STL files were exported to a computer-aided design (CAD) software program for the designing and milling of 36 complete contour zirconia crowns. The zirconia crown design was identical in the 3 groups for all parameters (default parameters in the CAD software program) with a 80-µm radial spacer 1 mm from the finish lines. The occlusal cement spacer was adjusted to 80 µm, 40 µm, and 0 µm for group 80-80, group 40-80, and group 0-80 respectively. The internal and marginal fit of the crowns were measured on their corresponding definitive dies with the replica technique. The Kruskal-Wallis test followed by the Dunn test with the Bonferroni correction was used for statistical analysis of the results (α=.05). RESULTS The modification of occlusal cement spacer significantly affected the marginal and internal fit of digitally manufactured crowns (P<.05). Group 0-80 and group 40-80 had similar marginal gap values, which were significantly lower than those of group 80-80 (P<.017). For internal fit accuracy, group 0-80 displayed significantly lower gap values than group 40-80 and group 80-80 for all measured areas. Group 40-80 had significantly lower gap values than group 80-80 at the mid-occlusal and axio-occlusal areas (P<.017). CONCLUSIONS Modifying occlusal cement spacer significantly affected the fit of digitally fabricated zirconia crowns. Reducing or eliminating occlusal spacer resulted in significantly improved fit accuracy.
Collapse
Affiliation(s)
- Heba Ibrahim
- Senior Researcher in Fixed Prosthodontics, Department of Conservative Dentistry, Alexandria University, Alexandria, Egypt
| | - Mohammed El Kateb
- Professor of Fixed Prosthodontics, Department of Conservative Dentistry, Alexandria University, Alexandria, Egypt
| | - Noha Morsy
- Lecturer of Fixed Prosthodontics, Department of Conservative Dentistry, Alexandria University, Alexandria, Egypt..
| |
Collapse
|
33
|
Li R, Xu T, Wang Y, Sun Y. Accuracy of zirconia crowns manufactured by stereolithography with an occlusal full-supporting structure: An in vitro study. J Prosthet Dent 2023; 130:902-907. [PMID: 35183363 DOI: 10.1016/j.prosdent.2022.01.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 12/31/2021] [Accepted: 01/04/2022] [Indexed: 10/19/2022]
Abstract
STATEMENT OF PROBLEM Additive manufacturing is emerging as an alternative method of fabricating dental restorations, but the support design needs to be optimized. PURPOSE The purpose of this in vitro study was to evaluate the 3-dimensional trueness and adaptations of zirconia crowns manufactured by stereolithography (SLA) with an occlusal full-supporting structure, compared with those SLA-printed with pillar supports, and those made by milling. MATERIAL AND METHODS A zirconia abutment was prepared, and an anatomic contour crown was designed. The crowns were manufactured by SLA and milling (n=6). For SLA manufacturing, a full-supporting base and pillar supports were designed. The 3-dimensional (3D) trueness of the fabricated crowns was characterized by 3D deviation analysis. The adaptations of crowns in the SLA-base and milling groups were measured by using a triple-scan method. Color-difference maps and the root mean square (RMS) values were used to characterize the 3D trueness. One-way analysis of variance (ANOVA) and Tukey post hoc test were used to analyze the difference in RMS values among the 3 groups, and Student t test was used to analyze the difference in cement-gap width between the milling group and the SLA group with the full-supporting base (α=.05). RESULTS The 3D deviation analysis showed that in the external area, the RMS value of the SLA-pillar group was significantly higher than that of the SLA-base and the milling groups (P<.05). In the intaglio area, the milling group showed a lower RMS value than the 2 SLA groups (P<.05). The color-difference maps showed the SLA-base group had smaller positive errors at the cusp inclines than the SLA-pillar group. No statistically significant difference was found in adaptations between the SLA-base and milling groups (P>.05). CONCLUSIONS The occlusal full-supporting base provided improved support in fabricating the crowns, and no remnants were left after removal. The zirconia crowns manufactured by SLA with an occlusal full-supporting structure had good external 3D trueness and clinically acceptable adaptation.
Collapse
Affiliation(s)
- Rong Li
- Doctoral student, Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health, Beijing Key Laboratory of Digital Stomatology, National Clinical Research Center for Oral Disease, Beijing, PR China
| | - Tan Xu
- Engineer, Porimy 3D Printing Technology Co. Ltd, Kunshan, PR China
| | - Yong Wang
- Professor, Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health, Beijing Key Laboratory of Digital Stomatology & National Clinical Research Center for Oral Disease, Beijing, PR China
| | - Yuchun Sun
- Professor, Center of Digital Dentistry, Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health, Beijing Key Laboratory of Digital Stomatology & National Clinical Research Center for Oral Disease, Beijing, PR China.
| |
Collapse
|
34
|
Altoman MS, Gadah TS, Alfaifi MA, Kattadiyil MT. Digital beading for a CAD-CAM framework for an implant-supported overdenture: A dental technique. J Prosthodont 2023; 32:867-870. [PMID: 37186337 DOI: 10.1111/jopr.13695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 04/14/2023] [Accepted: 04/17/2023] [Indexed: 05/17/2023] Open
Abstract
The analog technique of making bead lines for a metal superstructure framework for the maxillary implant-supported overdenture is created by scribing shallow grooves on the surface of a definitive gypsum cast. This report describes a digital technique that uses computer-aided design and computer-aided manufacturing technology to make dental bead lines on an intraoral impression without using the gypsum cast.
Collapse
Affiliation(s)
- Majed S Altoman
- Department of Prosthetic Dental Sciences, King Khalid University College of Dentistry, Abha, Saudi Arabia
- Advanced Specialty Education Program in Prosthodontics, Loma Linda University School of Dentistry, Loma Linda, California, USA
| | - Thuraya S Gadah
- Department of Prosthetic Dental Sciences, King Khalid University College of Dentistry, Abha, Saudi Arabia
| | - Mohammed A Alfaifi
- Department of Prosthetic Dental Sciences, King Khalid University College of Dentistry, Abha, Saudi Arabia
- Advanced Specialty Education Program in Prosthodontics, Loma Linda University School of Dentistry, Loma Linda, California, USA
| | - Mathew T Kattadiyil
- Advanced Specialty Education Program in Prosthodontics, Loma Linda University School of Dentistry, Loma Linda, California, USA
| |
Collapse
|
35
|
Dimitrova M, Vlahova A, Kalachev Y, Zlatev S, Kazakova R, Capodiferro S. Recent Advances in 3D Printing of Polymers for Application in Prosthodontics. Polymers (Basel) 2023; 15:4525. [PMID: 38231950 PMCID: PMC10708542 DOI: 10.3390/polym15234525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/15/2023] [Accepted: 11/22/2023] [Indexed: 01/19/2024] Open
Abstract
Contemporary mass media frequently depict 3D printing as a technology with widespread utilization in the creation of dental prosthetics. This paper endeavors to provide an evidence-based assessment of the current scope of 3D printing's integration within dental laboratories and practices. Its primary objective is to offer a systematic evaluation of the existing applications of 3D-printing technology within the realm of dental prosthetic restorations. Furthermore, this article delves into potential prospects, while also critically examining the sustained relevance of conventional dental laboratory services and manufacturing procedures. The central focus of this article is to expound upon the extent to which 3D printing is presently harnessed for crafting dental prosthetic appliances. By presenting verifiable data and factual insights, this article aspires to elucidate the actual implementation of 3D printing in prosthetic dentistry and its seamless integration into dental practices. The aim of this narrative review is twofold: firstly, to provide an informed and unbiased evaluation of the role that 3D printing currently plays within dental laboratories and practices; and secondly, to instigate contemplation on the transformative potential of this technology, both in terms of its contemporary impact and its future implications, while maintaining a balanced consideration of traditional dental approaches.
Collapse
Affiliation(s)
- Mariya Dimitrova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Angelina Vlahova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Yavor Kalachev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
| | - Stefan Zlatev
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Rada Kazakova
- Department of Prosthetic Dentistry, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria; (A.V.); (Y.K.); (S.Z.); (R.K.)
- CAD/CAM Center of Dental Medicine, Research Institute, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Saverio Capodiferro
- Department of Interdisciplinary Medicine, Aldo Moro, University of Bari, 70100 Bari, Italy;
| |
Collapse
|
36
|
Dolfini Alexandrino L, Martinez Antunes LH, Jardini Munhoz AL, Ricomini Filho AP, da Silva WJ. Mechanical and surface properties of Co-Cr alloy produced by additive manufacturing for removable partial denture frameworks. J Prosthet Dent 2023; 130:780-785. [PMID: 35184888 DOI: 10.1016/j.prosdent.2021.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 12/13/2021] [Accepted: 12/13/2021] [Indexed: 11/20/2022]
Abstract
STATEMENT OF PROBLEM Conventional analog methods have been replaced with digital methods for removable partial denture (RPD) frameworks. However, limited information is available regarding the build direction of RPD frameworks and its effect on properties. PURPOSE The purpose of this in vitro study was to evaluate the mechanical and surface properties of the cobalt chromium (Co-Cr) alloy produced at different build angles by the laser powder bed fusion additive manufacturing (AM) technology used for RPD framework fabrication. MATERIAL AND METHODS Plate-shaped Co-Cr specimens (n=6) were produced by the AM technology and divided into 3 groups depending on the build angle (0, 45, or 90 degrees). The elastic modulus and fracture properties were evaluated by flexural testing. Additionally, 15 disks were printed by using the same parameters of the plates (n=5) to analyze the surface hardness with microhardness testing, and surface properties were determined by surface free energy by using the contact angle and surface roughness measured by using a profilometer. Twelve Co-Cr cylindrical specimens were produced by using the same parameters (n=4), and their microstructure was examined by using an optical microscope. One-way ANOVA was used to evaluate the overall effects of the interaction between groups, and the Tukey test was applied when the interaction was statistically significant (α=.05). RESULTS The flexural strength showed a statistically significant difference (P<.05), with the peak value exhibited by the 0-degree group. A statistical difference was also observed between the angulation and modulus of elasticity; however, the highest value was exhibited by the 45-degree group. For the fracture topography, all groups observed a dimple-like fracture, although the 45-degree group showed wider cleavage planes of fractures than other angulations. For microhardness, the 0- and 45-degree groups exhibited a statistical difference in relation to the 90-degree group (P<.05). For surface properties, no statistically significant difference (P>.05) was found in any of the evaluated parameters. Dependence on the build angles was evidenced by the molten pool boundaries during observation of the microstructure. CONCLUSIONS The build angle influenced the flexural strength and microhardness of the Co-Cr alloy produced by AM; however, it does not affect surface free energy and surface roughness.
Collapse
Affiliation(s)
- Larissa Dolfini Alexandrino
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, SP, Brazil
| | | | - André Luiz Jardini Munhoz
- National Institute of Biofabrication, School of Chemical Engineering, University of Campinas (UNICAMP), Campinas, SP, Brazil
| | - Antônio Pedro Ricomini Filho
- Department of Physiological Sciences, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, SP, Brazil
| | - Wander José da Silva
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, SP, Brazil.
| |
Collapse
|
37
|
Kaba K, Purnell B, Liu Y, Royall PG, Alhnan MA. Computer numerical control (CNC) carving as an on-demand point-of-care manufacturing of solid dosage form: A digital alternative method for 3D printing. Int J Pharm 2023; 645:123390. [PMID: 37683980 DOI: 10.1016/j.ijpharm.2023.123390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 09/03/2023] [Accepted: 09/05/2023] [Indexed: 09/10/2023]
Abstract
Computer numerical control (CNC) carving is a widely used method of industrial subtractive manufacturing of wood, plastics, and metal products. However, there have been no previous reports of applying this approach to manufacture medicines. In this work, the novel method of tablet production using CNC carving is introduced for the first time. This report provides a proof-of-concept for applying subtractive manufacturing as an alternative to formative (powder compression) and additive (3D printing) manufacturing for the on-demand production of solid dosage forms. This exemplar manufacturing approach was employed to produce patient-specific hydrocortisone (HC) tablets for the treatment of children with congenital adrenal hyperplasia. A specially made drug-polymer cast based on polyethene glycol (PEG 6,000) and hydroxypropyl cellulose was produced using thermal casting. The cast was used as a workpiece and digitally carved using a small-scale 3-dimensional (3D) CNC carving. To establish the ability of this new approach to provide an accurate dose of HC, four different sizes of CNC carved tablet were manufactured to achieve HC doses of 2.5, 5, 7.5 and 10 mg with a relative standard deviation of the tablet weight in the range of 3.69-4.79%. In addition, batches of 2.5 and 5 mg HC tablets met the British Pharmacopeia standards for weight uniformity. Thermal analysis and X-ray powder diffraction indicated that the model drug was in amorphous form. In addition, HPLC analysis indicated a level of purity of 96.5 ± 1.1% of HC. In addition, the process yielded mechanically strong cylindrical tablets with tensile strength ranging from 0.49 to 1.6 MPa and friability values of <1%, whilst maintaining an aesthetic look. In vitro, HC release from the CNC-carved tablets was slower with larger tablet sizes and higher binder contents. This is the first report on applying CNC carving in the pharmaceutical context of producing solid dosage forms. The work showed the potential of this technology as an alternative method for the on-demand manufacturing of patient-specific dosage forms.
Collapse
Affiliation(s)
- Kazim Kaba
- Centre for Pharmaceutical Medicine Research, Institute of Pharmaceutical Science, King's College London, London SE1 9NH, United Kingdom
| | - Bryn Purnell
- Centre for Pharmaceutical Medicine Research, Institute of Pharmaceutical Science, King's College London, London SE1 9NH, United Kingdom
| | - Yujing Liu
- Centre for Pharmaceutical Medicine Research, Institute of Pharmaceutical Science, King's College London, London SE1 9NH, United Kingdom
| | - Paul G Royall
- Centre for Pharmaceutical Medicine Research, Institute of Pharmaceutical Science, King's College London, London SE1 9NH, United Kingdom
| | - Mohamed A Alhnan
- Centre for Pharmaceutical Medicine Research, Institute of Pharmaceutical Science, King's College London, London SE1 9NH, United Kingdom.
| |
Collapse
|
38
|
Filokyprou T, Kesterke MJ, Liu X, Cho SH, Revilla-León M. Effect of different surface treatments on the retention force of additively manufactured interim implant-supported crowns. J Prosthodont 2023. [PMID: 37823323 DOI: 10.1111/jopr.13783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 10/08/2023] [Accepted: 10/10/2023] [Indexed: 10/13/2023] Open
Abstract
PURPOSE To compare the effect of different pre-cementation surface treatments and bonding protocols on the retention force of additively manufactured (AM) implant-supported interim crowns. MATERIAL AND METHODS A total of 50 AM interim crowns (Temporary CB resin) were cemented on implant abutments. Five groups (n = 10) were established based on the different surface pre-treatments performed in the intaglio surface of the specimens: no surface pre-treatment (Group C or control), air-abraded with 50-μm aluminium oxide particles (Group AP), air-abraded with 50-μm aluminium oxide particles followed by the application of silane (Group AMP), silane (Group MP), and air-abraded with 30 μm silica-coated aluminum oxide particles followed by the application of silane (Group CMP). Each specimen was cemented into an implant abutment using a composite resin cement (Rely X Unicem2). Afterward, the specimens underwent retention testing with a Universal Instron machine. Pull-off forces (N) and modes of failure were registered. Statistical analysis was performed using Mann-Whitney U tests with Bonferroni corrections for multiple tests (α = 0.05). RESULTS The median retention force values were 233.27 ±79.28 N for Group Control, 398.59 ±68.59 N for Group MP, 303.21 ±116.80 N for Group AMP, 349.31 ±167.73 N for Group CMP, and 219.85 ± 55.88 N for Group AP. The pull-off forces were significantly greater for Group MP, while the differences between the remaining groups were not statistically significant (P > 0.05). Group AP showed the lowest retention force values among all the groups. Failure modes after the pull-off testing were predominantly adhesive and substrate failure of the AM interim material. CONCLUSIONS The surface treatment of the intaglio AM crown tested significantly influenced the retention force values measured. Pre-treatment with an MDP-containing silane improved the retentive force values computed, whereas pre-treatment with 50-μm Al2 O3 air-particle abrasion alone is not recommended prior to cementation on a titanium-based implant abutment.
Collapse
Affiliation(s)
- Thaleia Filokyprou
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA
| | - Matthew J Kesterke
- Department of Orthodontics, College of Dentistry, Texas A&M University, Dallas, Texas, USA
| | - Xiaohua Liu
- Department of Biomedical Sciences, College of Dentistry, Texas A&M University, Dallas, Texas, USA
| | - Seok-Hwan Cho
- Department of Prosthodontics, College of Dentistry and Dental Clinics, University of Iowa, Iowa City, Iowa, USA
| | - Marta Revilla-León
- Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts, USA
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA
- Kois Center, Seattle, Washington, USA
| |
Collapse
|
39
|
Sürer E, Ünal M, Gül Aygün EB, Ucar Y. Evaluating the conversion degree of interim restorative materials produced by different 3-dimensional printer technologies. J Prosthet Dent 2023; 130:654.e1-654.e6. [PMID: 37563026 DOI: 10.1016/j.prosdent.2023.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 07/03/2023] [Accepted: 07/05/2023] [Indexed: 08/12/2023]
Abstract
STATEMENT OF PROBLEM Three-dimensional (3D) printers are a relatively new technology, but the degree of conversion (DC) of the resin specimens produced by using this method is currently unknown. However, the DC of resin interim restorative materials is critical for their biocompatibility and physical properties. PURPOSE The purpose of this in vitro study was to evaluate the DC of interim restorative materials produced by using different 3D printer technologies and compare them with conventionally manufactured polymethyl methacrylate. MATERIAL AND METHODS Stereolithography, digital light processing, and liquid crystal display 3D printers were used as experimental groups, and a conventional (C) method was used as the control. Five different 3D printers (DWS Systems, Formlabs [FL], Asiga, Mega, and Vega) were included. The 3D printed specimens were designed in a rectangular prism geometry (10×4×2.5 mm) by using a computer-aided design software program (Materialise 3-matic) and printed with a layer thickness of 50 µm in the horizontal direction (n=15). Fourier transform infrared spectroscopy (FT-IR) spectra were measured in 3 steps: the liquid state of the resins, after washing with 99% isopropanol, and after final polymerization. For the C method, FT-IR spectra were assessed in 2 steps: immediately after mixing the liquid and powder and after polymerization. Statistical analysis of the data was performed with 1-way ANOVA followed by the post hoc Tukey honestly significant difference (HSD) test (α=.05). RESULTS There was no statistically significant difference in DC values between the 3D printed groups (P>.05). There was a statistically significant difference only between FL and the C in terms of DC (P=.042). CONCLUSIONS Three-dimensionally printed interim resin materials found comparable results with those of the C group. The DC was not affected by different 3D printing technologies.
Collapse
Affiliation(s)
- Ebru Sürer
- Research Assistant, Department of Prosthetic Dentistry, Faculty of Dentistry, Çukurova University, Adana, Turkey
| | - Mehmet Ünal
- Research Assistant, Department of Prosthetic Dentistry, Faculty of Dentistry, Çukurova University, Adana, Turkey
| | - Esma Başak Gül Aygün
- Associate Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Çukurova University, Adana, Turkey.
| | - Yurdanur Ucar
- Professor, Department of Prosthetic Dentistry, Faculty of Dentistry, Çukurova University, Adana, Turkey; and Private practice, Antalya, Turkey
| |
Collapse
|
40
|
Lee WJ, Jo YH, Yilmaz B, Yoon HI. Effect of build angle, resin layer thickness and viscosity on the surface properties and microbial adhesion of denture bases manufactured using digital light processing. J Dent 2023; 137:104608. [PMID: 37433380 DOI: 10.1016/j.jdent.2023.104608] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 06/20/2023] [Accepted: 07/08/2023] [Indexed: 07/13/2023] Open
Abstract
OBJECTIVES To investigate differences in the surface properties and microbial adhesion of denture base resins for digital light processing (DLP) with varying resin layer thicknesses (LT), build angles (BA), and resin viscosities. METHODS Two denture base resins for DLP with different viscosities (high and low) were used to prepare disk specimens applying two manufacturing parameters: 1) LT (50 or 100 μm) and 2) BA (0-, 45-, and 90-degree). Surface roughness and contact angle values were measured on the test surfaces (n=10 per group). Streptococcus oralis and Candida albicans absorbance was measured to assess microorganism attachment (n=6 per group). A three-way analysis of variance (ANOVA) was conducted, considering the main effects and their interactions (viscosity, LT, and BA). Post-hoc multiple pairwise comparisons were performed. All data were analyzed at a level of significance (P) of 0.05. RESULTS LT and BA significantly affected the surface roughness and contact angle of the specimens, depending on resin viscosity (P<.001). Absorbance measurement showed no significant interaction between the three factors (P>.05). However, significant interactions were observed between viscosity and BA (P<.05) and between LT and BA (P<.05). CONCLUSIONS Regardless of the viscosity and LT, discs with a 0-degree BA showed the least roughness. High-viscosity specimens fabricated with a 0-degree BA had the lowest contact angle. Regardless of the LT and viscosity, discs with a 0-degree BA showed the lowest S. oralis attachment. Attachment of C. albicans was the least on the disk with 50 μm LT, irrespective of the viscosity. CLINICAL SIGNIFICANCE Clinicians should consider the effects of LT and BA on surface roughness, contact angle, and microbial adhesion of DLP-generated dentures, which can differ depending on resin viscosity. A 50 μm LT and 0-degree BA can be used with a high-viscosity resin to fabricate denture bases with less microbial adhesion.
Collapse
Affiliation(s)
- Won-Jun Lee
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Ye-Hyeon Jo
- Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - Hyung-In Yoon
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
41
|
Abduo J, Ho G, Centorame A, Chohan S, Park C, Abdouni R, Le P, Ngo C. Marginal Accuracy of Monolithic and Veneered Zirconia Crowns Fabricated by Conventional and Digital Workflows. J Prosthodont 2023; 32:706-713. [PMID: 36321644 DOI: 10.1111/jopr.13618] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 10/21/2022] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To compare the marginal accuracy of zirconia crowns fabricated by different workflows (conventional and digital) and designs (monolithic and veneered). MATERIALS AND METHODS A prepared maxillary first molar was used for the study. Four workflow combinations were evaluated: (1) intraoral scanning and monolithic zirconia (IOS-M), (2) intraoral scanning and veneered zirconia (IOS-V), (3) conventional impression and monolithic zirconia (IMP-M), and (4) conventional impression and veneered zirconia (IMP-V). All of the specimens had similar designs. The veneered groups had a buccal cutback for esthetic veneer application. A total of 10 crowns were produced in each workflow. The vertical and horizontal marginal accuracies were measured with a traveling microscope. Depending on the normality of the data, one-way analysis of variance test or Kruskal-Wallis test were applied to evaluate the differences among the groups (α = 0.05). RESULTS The most superior vertical marginal accuracy was observed for IOS-V (mean = 22.5 μm; SD = 6.7 μm), followed by IMP-V (mean = 23.9 μm; SD = 7.8 μm), IOS-M (mean = 28.7 μm; SD = 10.3 μm), and IMP-M (mean = 39.8 μm; SD = 22.0 μm), respectively (p < 0.001). The IOS-M had the greatest mean horizontal discrepancies (mean = 23.9 μm; SD = 4.3 μm) followed by IMP-M (mean = 21.3 μm; SD = 5.7 μm), IMP-V (mean = 19.2 μm; SD = 5.3 μm) and IOS-V (mean = 17.6 μm; SD = 5.7 μm) (p < 0.001). CONCLUSIONS Monolithic zirconia crowns fabricated digitally had superior marginal accuracy than monolithic zirconia crowns fabricated conventionally. Esthetic buccal veneering of predominantly monolithic zirconia copings improved the vertical and horizontal marginal accuracies.
Collapse
Affiliation(s)
- Jaafar Abduo
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Grace Ho
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Alannah Centorame
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Simran Chohan
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Clara Park
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Ramiz Abdouni
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Phillip Le
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Christopher Ngo
- Restorative Section, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| |
Collapse
|
42
|
Thomas AA, Daniel AY, Gandhi N, Roy N, Varghese KG, Wadhwa S, Mathew JE. Surface trueness and precision of interim restorations fabricated by digital light processing and CAD-CAM milling systems. J Prosthet Dent 2023; 130:611.e1-611.e7. [PMID: 37643941 DOI: 10.1016/j.prosdent.2023.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 07/13/2023] [Accepted: 07/13/2023] [Indexed: 08/31/2023]
Abstract
STATEMENT OF PROBLEM The development of digital dental technologies has enabled clinicians to use additive and subtractive manufacturing techniques to fabricate interim restorations. However, knowledge of the trueness and precision of such restorations fabricated using digital light processing (DLP) and computer-aided design and computer-aided manufacturing (CAD-CAM) methods is limited. PURPOSE The purpose of this in vitro study was to assess and compare the accuracy of interim crowns fabricated using DLP and CAD-CAM methods. MATERIAL AND METHODS A typodont mandibular first molar was prepared for a ceramic crown, and a digital scan (Medit T500) was obtained to design interim crowns by using the CAD software program. The CAD data were designated as the reference data. A total of 20 crowns were fabricated by DLP and CAD-CAM technology. The fabricated interim crowns were further scanned using a laboratory scanner and were superimposed with the CAD data by using a 3-dimensional (3D) point cloud assessing software program (CloudCompare) for the evaluation of trueness and precision. Root mean square values (RMS) were obtained for the evaluation of discrepancies. The Student t test was used to compare data as the Shapiro-Wilk test confirmed the normal distribution. RESULTS RMS values for the trueness values of the external and intaglio surfaces of the 3D printed and milled interim crown displayed no statistically significant differences (P>.05). Precision for the external surface reported significance (P<.05), whereas that for the intaglio surface reported no significance (P>.05). CONCLUSIONS The accuracy of interim crowns fabricated by using DLP was comparable with that of milled crowns. Both manufacturing systems produced a true reproduction of the CAD. As for precision, the external surface of the DLP interim crown was statistically different from that of the milled group as it relates to the CAD.
Collapse
Affiliation(s)
- Achsah Ann Thomas
- Postgraduate Resident, Department of Prosthodontics and Crown & Bridge, Christian Dental College, Ludhiana, Punjab, India.
| | - Angleena Y Daniel
- HOD & Professor, Department of Prosthodontics and Crown & Bridge, Christian Dental College, Ludhiana, Punjab, India
| | - Nitasha Gandhi
- Ex-Professor, Department of Prosthodontics and Crown & Bridge, Christian Dental College, Ludhiana, Punjab, India
| | - Neethu Roy
- Associate Professor, Department of Prosthodontics and Crown & Bridge, Christian Dental College, Ludhiana, Punjab, India
| | - Kevin George Varghese
- Assistant Professor, Department of Prosthodontics and Crown & Bridge, Christian Dental College, Ludhiana, Punjab, India..
| | - Samiksha Wadhwa
- Postgraduate Resident, Department of Prosthodontics and Crown & Bridge, Christian Dental College, Ludhiana, Punjab, India
| | - Jemin Elizabeth Mathew
- Postgraduate Resident, Department of Prosthodontics and Crown & Bridge, Christian Dental College, Ludhiana, Punjab, India
| |
Collapse
|
43
|
Palavicini J, Quin SL, Zakkour W, Zakkour K, Manafi Varkiani S, Xu X, Lawson NC, Nejat AH. Bond Strength of Reline Materials to 3D-Printed Provisional Crown Resins. Polymers (Basel) 2023; 15:3745. [PMID: 37765598 PMCID: PMC10537094 DOI: 10.3390/polym15183745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 08/31/2023] [Accepted: 09/05/2023] [Indexed: 09/29/2023] Open
Abstract
(1) Purpose: The aim of the present study was to compare the bond strength between two 3D-printed resins designed for long-term provisional crowns and three different reline materials. (2) Materials and Methods: Rectangular specimens were prepared from two 3D-printed resins (Envision Tech and NextDent C&B) and a conventional self-cure PMMA. Transparent tubes filled with three different reline materials including composite resin, Bis-acryl, and PMMA were bonded to the 3D-printed specimens (n = 11 per group, total of 6 study groups). Tubes filled with PMMA were bonded to the prepared PMMA specimens which served as the control group (n = 11, control group). The specimens were subjected to a shear bond strength (SBS) test, and mode of failure was recorded using light microscopy. Statistical analysis was performed using a one-way ANOVA and post hoc Tukey's tests (alpha = 0.05). (3) Results: The highest SBS value was achieved to both 3D-printed materials with the PMMA reline material. The bond to both 3D-printed materials was lower with Bis-acrylic or composite resin relines in comparison to that with PMMA (p-value < 0.05). No significant difference was found between the control PMMA group and either 3D-printed material when relined with PMMA (p-value > 0.05). (4) Conclusion: The tested 3D-printed resins achieved a clinically acceptable bond strength when relined with PMMA.
Collapse
Affiliation(s)
- Jorge Palavicini
- Department of Prosthodontics, Louisiana State University Health Science Center, School of Dentistry, New Orleans, LA 70119, USA
| | - Sherrod L. Quin
- Department of Comprehensive Dentistry, Louisiana State University Health Science Center, School of Dentistry, New Orleans, LA 70119, USA
| | | | - Karim Zakkour
- Department of General Surgery, Saint George University of Beirut, Beirut 1100-2807, Lebanon
| | - Safa Manafi Varkiani
- Henry M. Goldman School of Dental Medicine, Boston University, Boston, MA 02118, USA
| | - Xiaoming Xu
- Department of Oral and Craniofacial Biology, Louisiana State University Health Science Center, School of Dentistry, New Orleans, LA 70119, USA
| | - Nathaniel C. Lawson
- Division of Dental Materials, University of Alabama at Birmingham School of Dentistry, Birmingham, AL 35233, USA
| | - Amir Hossein Nejat
- Department of Prosthodontics, Louisiana State University Health Science Center, School of Dentistry, New Orleans, LA 70119, USA
| |
Collapse
|
44
|
Saláta J, Szabó F, Csuti P, Antal M, Márton P, Hermann P, Borbély J, Ábrám E. Effect of thickness, translucency, and substrates on the masking ability of a polymer-infiltrated ceramic-network material. J ESTHET RESTOR DENT 2023; 35:886-895. [PMID: 37335072 DOI: 10.1111/jerd.13071] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/23/2023] [Accepted: 06/03/2023] [Indexed: 06/21/2023]
Abstract
OBJECTIVE The aim of this in vitro study is to evaluate the masking ability of polymer-infiltrated ceramic-network materials (PICN) with different translucencies and thicknesses on multiple types of substrates. MATERIALS AND METHODS Ceramic samples were prepared of VITA ENAMIC blocks in two different translucencies (2M2-T, 2M2-HT) in a thickness range of 0.5-2.5 mm (±0.05 mm). Layered specimens were obtained using composite substrates in nine shades and transparent try-in paste. Spectral reflectance of specimens was measured using a Konica Minolta CM-3720d spectrophotometer and D65 standard illumination. CIEDE2000 color difference (ΔE00 ) between two samples was evaluated using 50%:50% perceptibility and acceptability thresholds. Specular component of the reflection was examined with Specular Component Excluded (SCE) and Included (SCI) settings. Statistical evaluation was performed by linear regression analysis, Kruskal-Wallis test, and multiplicative effect analysis. RESULTS An increase in thickness of 0.5 mm reduces ΔE00 of HT samples to 73.5%, of T samples to 60.5% (p < 0.0001). Five substrates with HT specimens, and three substrates with T specimens had significantly different results from average (p < 0.05). There is a significant difference between SCE and SCI data depending on the wavelength (p < 0.0001). CONCLUSIONS Masking ability of PICN materials is influenced by the thickness and translucency of the ceramic, and by the substrate. Reflection of the examined PICN material is characterized by both diffuse and specular reflection. CLINICAL SIGNIFICANCE Although PICN materials have been available on the market for 10 years now, there is a lack of information regarding their masking ability. Acquiring in-depth data and thereby practical experience of the factors affecting the esthetics of PICN materials is essential for creating perfectly lifelike restorations.
Collapse
Affiliation(s)
- József Saláta
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
- Károly Rácz Doctoral School of Clinical Medicine, Semmelweis University, Budapest, Hungary
| | - Ferenc Szabó
- LightingLab, Calibration Laboratory Ltd, Veszprém, Hungary
| | - Péter Csuti
- LightingLab, Calibration Laboratory Ltd, Veszprém, Hungary
| | - Melinda Antal
- Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Péter Márton
- Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Péter Hermann
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Emese Ábrám
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| |
Collapse
|
45
|
Salah K, Sherif AH, Mandour MH, Nossair SA. Optical effect of rapid sintering protocols on different types of zirconia. J Prosthet Dent 2023; 130:253.e1-253.e7. [PMID: 37330359 DOI: 10.1016/j.prosdent.2023.05.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 05/07/2023] [Accepted: 05/09/2023] [Indexed: 06/19/2023]
Abstract
STATEMENT OF PROBLEM Rapid sintering protocols are available for the fabrication of zirconia restorations, but whether rapid sintering influences color or translucency is unclear. PURPOSE The purpose of this in vitro study was to investigate the effect of different rapid sintering protocols on the color and translucency of cubic and tetragonal zirconias. MATERIAL AND METHODS Sixty disk-shaped specimens of 1-mm-thick cubic (DD CubeX2) and tetragonal (DD Bio ZX2) zirconia were investigated. Specimens of each type of zirconia were divided into three groups: conventional, speed, and superspeed sintering protocols. The conventional group of each zirconia type served as the control for calculating color differences. Translucency for each group was assessed by the translucency parameter and contrast ratio. Two-way analysis of variance was used for statistical analysis of the data (α=.05). RESULTS The translucency of cubic and tetragonal zirconia decreased after speed and superspeed sintering (P<.001). Superspeed sintering resulted in a greater color change than speed sintering (P<.001). CONCLUSIONS Rapid sintering protocols produced a significant effect on the color and translucency of cubic and tetragonal zirconias.
Collapse
Affiliation(s)
- Kerolos Salah
- Former Postgraduate student, Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Future University, New Cairo, Egypt.
| | - Ashraf Hussein Sherif
- Professor, Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Future University, New Cairo, Egypt
| | - Mona H Mandour
- Professor, Department of Crown and Bridge, Faculty of Dental Medicine, Al-Azhar University, Girls' Branch, Cairo, Egypt
| | - Shereen Ahmed Nossair
- Assistant Professor, Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Future University, New Cairo, Egypt
| |
Collapse
|
46
|
Oh R, Lim JH, Lee CG, Lee KW, Kim SY, Kim JE. Effects of washing solution temperature on the biocompatibility and mechanical properties of 3D-Printed dental resin material. J Mech Behav Biomed Mater 2023; 143:105906. [PMID: 37178635 DOI: 10.1016/j.jmbbm.2023.105906] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 05/07/2023] [Accepted: 05/08/2023] [Indexed: 05/15/2023]
Abstract
The use of digital manufacturing, particularly additive manufacturing using three-dimensional (3D) printing, is expanding in the field of dentistry. 3D-printed resin appliances must undergo an essential process, post-washing, to remove residual monomers; however, the effect of the washing solution temperature on the biocompatibility and mechanical properties remains unclear. Therefore, we processed 3D-printed resin samples under different post-washing temperatures (without temperature control (N/T), 30 °C, 40 °C, and 50 °C) for different durations (5, 10, 15, 30, and 60 min) and evaluated the degree of conversion rate, cell viability, flexural strength, and Vickers hardness. Increasing the washing solution temperature significantly improved the degree of conversion rate and cell viability. Conversely, increasing the solution temperature and time decreased the flexural strength and microhardness. This study confirmed that the washing temperature and time influence the mechanical and biological properties of the 3D-printed resin. Washing 3D-printed resin at 30 °C for 30 min was most efficient to maintain optimal biocompatibility and minimize changes of mechanical properties.
Collapse
Affiliation(s)
- Rojee Oh
- Dental Hospital, Veterans Health Service Medical Center, Seoul, 05368, Republic of Korea; Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Jung-Hwa Lim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Chan-Gyu Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Oral Science Research Center, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Keun-Woo Lee
- Dental Hospital, Veterans Health Service Medical Center, Seoul, 05368, Republic of Korea; Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Sung-Yong Kim
- Dental Hospital, Veterans Health Service Medical Center, Seoul, 05368, Republic of Korea.
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|
47
|
Alshamrani A, Alhotan A, Kelly E, Ellakwa A. Mechanical and Biocompatibility Properties of 3D-Printed Dental Resin Reinforced with Glass Silica and Zirconia Nanoparticles: In Vitro Study. Polymers (Basel) 2023; 15:polym15112523. [PMID: 37299322 DOI: 10.3390/polym15112523] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 05/26/2023] [Accepted: 05/29/2023] [Indexed: 06/12/2023] Open
Abstract
This study aimed to assess the mechanical and biocompatibility properties of dental resin reinforced with different nanoparticle additives. Temporary crown specimens were 3D-printed and grouped based on nanoparticle type and amount, including zirconia and glass silica. Flexural strength testing evaluated the material's ability to withstand mechanical stress using a three-point bending test. Biocompatibility was tested using MTT and dead/live cell assays to assess effects on cell viability and tissue integration. Fractured specimens were analysed using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) for fracture surface examination and elemental composition determination. Results show that adding 5% glass fillers and 10-20% zirconia nanoparticles significantly improves the flexural strength and biocompatibility of the resin material. Specifically, the addition of 10%, 20% zirconia, and 5% glass silica by weight significantly increases the flexural strength of the 3D-printed resins. Biocompatibility testing reveals cell viabilities greater than 80% in all tested groups. Reinforced 3D-printed resin holds clinical potential for restorative dentistry, as zirconia and glass fillers have been shown to enhance mechanical and biocompatibility properties of dental resin, making it a promising option for dental restorations. The findings of this study may contribute to the development of more effective and durable dental materials.
Collapse
Affiliation(s)
- Abdullah Alshamrani
- Oral Rehabilitation & Dental Biomaterial and Bioengineering, The University of Sydney, Sydney 2006, Australia
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh P.O. Box 12372, Saudi Arabia
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh P.O. Box 12372, Saudi Arabia
| | - Elizabeth Kelly
- The Cellular and Molecular Pathology Research Unit, Oral Pathology and Oral Medicine, School of Dentistry, The University of Sydney, Westmead Hospital, Westmead 2145, Australia
| | - Ayman Ellakwa
- Oral Rehabilitation & Dental Biomaterial and Bioengineering, The University of Sydney, Sydney 2006, Australia
| |
Collapse
|
48
|
Lyu J, Yang X, Li Y, Tan J, Liu X. Dimensional accuracy and clinical adaptation of monolithic zirconia crowns fabricated with the nanoparticle jetting technique. J Prosthet Dent 2023:S0022-3913(23)00260-3. [PMID: 37217418 DOI: 10.1016/j.prosdent.2023.04.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 04/07/2023] [Accepted: 04/11/2023] [Indexed: 05/24/2023]
Abstract
STATEMENT OF PROBLEM The nanoparticle jetting (NPJ) technique is a recently developed additive manufacturing method that may have useful dental applications. The manufacturing accuracy and clinical adaptation of zirconia monolithic crowns fabricated with NPJ are unknown. PURPOSE The purpose of this in vitro study was to compare the dimensional accuracy and clinical adaptation of zirconia crowns fabricated with NPJ and those fabricated with subtractive manufacturing (SM) and digital light processing (DLP). MATERIAL AND METHODS Five standardized typodont right mandibular first molars were prepared for ceramic complete crowns, and 30 zirconia monolithic crowns were fabricated using SM, DLP, and NPJ (n=10) with a completely digital workflow. The dimensional accuracy at the external, intaglio, and marginal areas was determined by superimposing the scanned data and computer-aided design data of the crowns (n=10). Occlusal, axial, and marginal adaptations were evaluated by using a nondestructive silicone replica and dual scanning method. The 3-dimensional discrepancy was evaluated to determine clinical adaptation. Differences among test groups were analyzed by using a MANOVA and the post hoc least significant difference test for normally distributed data or the Kruskal-Wallis test with Bonferroni correction for nonnormally distributed data (α=.05). RESULTS Significant differences were found in the dimensional accuracy and clinical adaptation among the groups (P<.001). The NPJ group had a lower overall root mean square (RMS) value for dimensional accuracy (22.9 ±1.4 μm) than the SM (27.3 ±5.0 μm) and DLP (36.4 ±5.9 μm) groups (P<.001). The NPJ group had a lower external RMS value (23.0 ±3.0 μm) than the SM group (28.9 ±5.4 μm) (P<.001) and equivalent marginal and intaglio RMS values than the SM group. The DLP group had larger external (33.3 ±4.3 μm), intaglio (36.1 ±10.7 μm), and marginal (79.4 ±12.9 μm) deviations than the NPJ and SM groups (P<.001). With regard to clinical adaptation, the marginal discrepancy was smaller in the NPJ group (63.9 ±27.3 μm) than in the SM group (70.8 ±27.5 μm) (P<.001). No significant differences were found between the SM and NPJ groups in terms of the occlusal (87.2 ±25.5 and 80.5 ±24.2 μm, respectively) and axial (39.1 ±19.7 and 38.4 ±13.7 μm, respectively) discrepancies. The DLP group had larger occlusal (239.0 ±60.1 μm), axial (84.9 ±29.1 μm), and marginal (140.4 ±84.3 μm) discrepancies than the NPJ and SM groups (P<.001). CONCLUSIONS Monolithic zirconia crowns fabricated using NPJ have higher dimensional accuracy and clinical adaptation than those fabricated using SM or DLP.
Collapse
Affiliation(s)
- Jizhe Lyu
- Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China
| | - Xu Yang
- Clinical Associate Professor, Department Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, China
| | - Yi Li
- Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, China
| | - Jianguo Tan
- Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, China
| | - Xiaoqiang Liu
- Associate Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, China.
| |
Collapse
|
49
|
El Samahy MM, Abdelhamid AM, El Shabrawy SM, Hanno KI. Evaluation of physicomechanical properties of milled versus 3D-printed denture base resins: A comparative in vitro study. J Prosthet Dent 2023; 129:797.e1-797.e7. [PMID: 37121625 DOI: 10.1016/j.prosdent.2023.03.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 03/14/2023] [Accepted: 03/14/2023] [Indexed: 05/02/2023]
Abstract
STATEMENT OF PROBLEM Studies comparing the physicomechanical characteristics of denture base resins manufactured by computer-aided design and computer-aided manufacturing (CAD-CAM) milling and 3-dimensional (3D) printing are sparse, resulting in challenges when choosing a fabrication method for complete dentures. PURPOSE The purpose of this in vitro study was to evaluate and compare the impact strength, flexural strength, and the surface roughness of denture base resins manufactured by CAD-CAM milling and 3D printing before and after thermocycling and polishing. MATERIAL AND METHODS Evaluation of the physicomechanical properties (n=35) was completed before and after 500 thermocycles. Impact strength (n=14) was measured with a Charpy impact tester and flexural strength (n=14) with the 3-point bend test. Surface roughness (Ra) was evaluated (n=7) with a profilometer before and after thermocycling and polishing and by viewing the surface topography before and after polishing using a scanning electron microscope at ×2000. The Mann-Whitney U test and Wilcoxon sign rank test were used for statistical analysis (α=.05). RESULTS Milled specimens showed statistically significantly higher impact strength before thermocycling and statistically significantly higher flexural strength before and after thermocycling (P=.004) compared with 3D-printed specimens. The Ra values for the milled group were significantly lower than for the 3D-printed group both before and after thermocycling (P=.006) and after polishing (P=.027). Thermocycling resulted in a statistically significant difference in flexural strength (P=.018) in both groups and in surface roughness in the milled group (P=.048); but no significant effect was found on impact strength (P>.05). Ra values for the 3D-printed group decreased after polishing (P=.048). CONCLUSIONS Milled specimens had higher flexural and impact strength and lower surface roughness values than 3D-printed specimens. Polishing significantly reduced the surface roughness in 3D-printed specimens but had no significant effect on milled specimens.
Collapse
Affiliation(s)
- Marwa M El Samahy
- Resident, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt
| | - Ahmed M Abdelhamid
- Professor, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt
| | - Sonia M El Shabrawy
- Professor, Department of Dental Biomaterials, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt
| | - Kenda I Hanno
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, University of Alexandria, Alexandria, Egypt.
| |
Collapse
|
50
|
Attia MA, Blunt L, Bills P, Tawfik A, Radawn M. Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns. J Prosthet Dent 2023:S0022-3913(23)00183-X. [PMID: 37072286 DOI: 10.1016/j.prosdent.2023.03.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/18/2023] [Accepted: 03/20/2023] [Indexed: 04/20/2023]
Abstract
STATEMENT OF PROBLEM Polyetheretherketone (PEEK) has been increasingly used as a framework material in prosthetic dentistry. However, data on the marginal and internal fit of PEEK restorations fabricated by using either the computer-aided design and computer-aided manufacturing (CAD-CAM) or heat-pressing technique are sparse. PURPOSE The aim of this in vitro study was to assess the marginal and internal fit of milled and pressed PEEK single crowns by using microcomputed tomography (μCT). MATERIAL AND METHODS A custom-made, single stainless-steel die was designed to replicate a maxillary first premolar prepared for a ceramic crown. PEEK copings (N=30) were fabricated and allocated to 3 groups (n=10) according to the fabrication technique: milled from a prefabricated PEEK blank, heat pressed from PEEK pellets, and heat pressed from PEEK granules. All copings were veneered with a composite resin material. The marginal fit was recorded at 4 predetermined points and the internal fit at 8 predetermined points on each crown by using μCT. Two-way ANOVA, pair-wise Tukey honestly significant difference (HSD), and simple main effect tests were used for statistical analysis of the data (α=.05). RESULTS Concerning marginal fit, the milled crowns demonstrated the best marginal fit overall (44 ±3 μm), followed by those pressed from pellets (92 ±3 μm), and finally by those pressed from granules (137 ±7 μm) (P<.001). The interaction between the effects of the fabrication technique and the measurement point on the marginal fit was not statistically significant (P=.142). The milled crowns demonstrated the lowest mean gap values overall, followed by those pressed from pellets and those pressed from granules (P<.001). The interaction between the effects of the fabrication technique and the measurement point on the internal fit was statistically significant (P<.001). Except for the distal occlusal gap and mesial occlusal gap, all tested groups showed a statistically significant difference (P<.001). In addition, statistically significant differences were observed among all measurement points in different fabrication techniques (P<.001). CONCLUSIONS The marginal and internal fit of milled PEEK crowns was significantly better than pressed crowns. However, both CAD-CAM and heat-pressing techniques produced PEEK crowns with a clinically acceptable marginal and internal fit. The mean marginal gap of the PEEK crowns pressed from granules was above the range of clinically acceptable value.
Collapse
Affiliation(s)
- Mazen A Attia
- Associate Professor, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt.
| | - Liam Blunt
- Professor, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Paul Bills
- Professor, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Ahmed Tawfik
- PhD Researcher, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
| | - Mohamed Radawn
- Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt
| |
Collapse
|