Sau A, Ahmed A, Chen JY, Pastika L, Wright I, Li X, Handa B, Qureshi N, Koa-Wing M, Keene D, Malcolme-Lawes L, Varnava A, Linton NWF, Lim PB, Lefroy D, Kanagaratnam P, Peters NS, Whinnett Z, Ng FS. Machine learning-derived cycle length variability metrics predict spontaneously terminating ventricular tachycardia in implantable cardioverter defibrillator recipients. EUROPEAN HEART JOURNAL. DIGITAL HEALTH 2024; 5:50-59. [PMID: 38264702 PMCID: PMC10802825 DOI: 10.1093/ehjdh/ztad064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 10/06/2023] [Accepted: 10/16/2023] [Indexed: 01/25/2024]
Abstract
Aims Implantable cardioverter defibrillator (ICD) therapies have been associated with increased mortality and should be minimized when safe to do so. We hypothesized that machine learning-derived ventricular tachycardia (VT) cycle length (CL) variability metrics could be used to discriminate between sustained and spontaneously terminating VT. Methods and results In this single-centre retrospective study, we analysed data from 69 VT episodes stored on ICDs from 27 patients (36 spontaneously terminating VT, 33 sustained VT). Several VT CL parameters including heart rate variability metrics were calculated. Additionally, a first order auto-regression model was fitted using the first 10 CLs. Using features derived from the first 10 CLs, a random forest classifier was used to predict VT termination. Sustained VT episodes had more stable CLs. Using data from the first 10 CLs only, there was greater CL variability in the spontaneously terminating episodes (mean of standard deviation of first 10 CLs: 20.1 ± 8.9 vs. 11.5 ± 7.8 ms, P < 0.0001). The auto-regression coefficient was significantly greater in spontaneously terminating episodes (mean auto-regression coefficient 0.39 ± 0.32 vs. 0.14 ± 0.39, P < 0.005). A random forest classifier with six features yielded an accuracy of 0.77 (95% confidence interval 0.67 to 0.87) for prediction of VT termination. Conclusion Ventricular tachycardia CL variability and instability are associated with spontaneously terminating VT and can be used to predict spontaneous VT termination. Given the harmful effects of unnecessary ICD shocks, this machine learning model could be incorporated into ICD algorithms to defer therapies for episodes of VT that are likely to self-terminate.
Collapse
Affiliation(s)
- Arunashis Sau
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Amar Ahmed
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
| | - Jun Yu Chen
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
| | - Libor Pastika
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
| | - Ian Wright
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Xinyang Li
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
| | - Balvinder Handa
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Norman Qureshi
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Michael Koa-Wing
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Daniel Keene
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Louisa Malcolme-Lawes
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Amanda Varnava
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Nicholas W F Linton
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Phang Boon Lim
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - David Lefroy
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Prapa Kanagaratnam
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Nicholas S Peters
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Zachary Whinnett
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
| | - Fu Siong Ng
- National Heart and Lung Institute, Hammersmith Campus, Imperial College London, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare NHS Trust, 72 Du Cane Road, W12 0HS, London, UK
- Department of Cardiology, Chelsea and Westminster Hospital NHS Foundation Trust, 369 Fulham Road, SW10 9NH, London, UK
| |
Collapse
|
2
|
Arcinas LA, Sheldon RS. Complications related to pacemakers and other cardiac implantable electronic devices: essentials for internists and emergency physicians. Intern Emerg Med 2023; 18:851-862. [PMID: 36892799 DOI: 10.1007/s11739-023-03227-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Accepted: 02/11/2023] [Indexed: 03/10/2023]
Abstract
With the aging population, improving technology, and expanding indications for diagnosing and treating arrhythmias and heart failure, many patients are receiving cardiac implantable electronic devices (CIEDs) such as pacemakers and implantable cardioverter defibrillators. Consequently, patients with CIEDs are frequently encountered in the emergency department and in the wards. It is imperative that emergency physicians and internists have a strong foundation on CIEDs and their potential complications. This review aims to help physicians develop a framework in approaching CIEDs and to recognize and manage clinical scenarios that may arise from CIED complications.
Collapse
Affiliation(s)
- Liane A Arcinas
- Section of Cardiology, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, 3280 Hospital Drive NW, Calgary, AB, T2N 4N1, Canada.
| | - Robert S Sheldon
- Section of Cardiology, Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, 3280 Hospital Drive NW, Calgary, AB, T2N 4N1, Canada
| |
Collapse
|
3
|
Morrison N, Voleti N, Cannizzaro M. A Case of 25 Inappropriate Automatic Implantable Cardioverter Defibrillator Shocks and 22 Episodes of Antitachycardia Pacing. Cureus 2023; 15:e35634. [PMID: 37009346 PMCID: PMC10065352 DOI: 10.7759/cureus.35634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/28/2023] [Indexed: 03/05/2023] Open
Abstract
An implantable cardioverter defibrillator (ICD) can save lives from fatal tachyarrhythmias. In rare cases, these devices can fail or malfunction. We present a case of a patient that suffered from 25 inappropriate shocks and 22 episodes of antitachycardia pacing (ATP), secondary to a probable non-traumatic dual lead fracture. One episode of ATP induced an R-on-T phenomenon, causing monomorphic ventricular tachycardia in the patient. The inappropriately functioning ICD also required two magnets to be placed on the patient's chest in the emergency department to convert the device to an asynchronous mode. An unexpected case of this magnitude and in such a brief timeframe has not been reported in prior ICD studies.
Collapse
|
4
|
Jawaid A, Chokshi M, Zareba W, Schuger C, Daubert J, McNitt S, Singh J, Goldenberg I, Kutyifa V. Effect of Novel Programming on Inappropriate Implantable Cardioverter-Defibrillator Therapy in Patients With Very Low Ejection Fraction (from A MADIT-RIT). Am J Cardiol 2022; 182:32-39. [PMID: 36075757 DOI: 10.1016/j.amjcard.2022.07.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 06/23/2022] [Accepted: 07/05/2022] [Indexed: 11/19/2022]
Abstract
The Multicenter Automatic Defibrillator Implantation Trial - Reduce Inappropriate Therapy showed a significant reduction in the risk of inappropriate therapy in patients with a programmed high-rate cutoff ≥200 beats per minute or delayed therapy for events ≥170 beats per minute compared with conventional programming. We aimed to characterize outcomes by left ventricular ejection fraction (LVEF) ranges for patients with high-rate, delayed, or conventional implantable cardioverter-defibrillator programming. We assessed the effect of LVEF (LVEF <15%, LVEF 15% to 25%, LVEF >25%) on the risk of inappropriate conventional implantable cardioverter-defibrillator therapy and death in Multicenter Automatic Defibrillator Implantation Trial - Reduce Inappropriate Therapy. Inappropriate therapies and death were independently evaluated by the adjudication committee. Statistical methods involved Kaplan-Meier time-to-event graphs and Cox proportional hazards regression analyses. The study involved 140 patients (9%) with LVEF 15%, 585 with LVEF 15% to 25% (39%), and 774 with LVEF >25% (52%). High-rate or delayed programming significantly reduced the risk of inappropriate therapy compared with conventional programming in patients with all LVEFs (p <0.001 for all LVEF). Patients with LVEF <15% had an exceptional 97% lower risk of inappropriate therapy, with high-rate programming than conventional programming (hazard ratio 0.028, p = 0.001), without an increase in mortality. High-rate and delayed programming is superior to conventional programming in all LVEF ranges, without adverse effects.
Collapse
Affiliation(s)
- Anas Jawaid
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - Moulin Chokshi
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - Wojciech Zareba
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - Claudio Schuger
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - James Daubert
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - Scott McNitt
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - Jagmeet Singh
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - Ilan Goldenberg
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York
| | - Valentina Kutyifa
- Clinical Cardiovascular Research Center, Department of Medicine, University of Rochester Medical Center, Rochester, New York.
| |
Collapse
|
5
|
Sharif ZI, Lubitz SA. Ventricular arrhythmia management in patients with genetic cardiomyopathies. Heart Rhythm O2 2021; 2:819-831. [PMID: 34988533 PMCID: PMC8710624 DOI: 10.1016/j.hroo.2021.10.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Genetic cardiomyopathies are associated with increased risk for cardiac arrhythmias and sudden cardiac death. The management of ventricular arrhythmias (VAs) in patients with these conditions can be nuanced due to particular disease-based considerations, yet data specifically addressing management in these patients are limited. Here we describe the current evidence-based approach to the management of ventricular rhythm disorders in patients with genetic forms of cardiomyopathy, namely, hypertrophic cardiomyopathy, arrhythmogenic cardiomyopathy, left ventricular noncompaction, and Brugada syndrome, including recommendations from consensus guideline statements when available.
Collapse
Affiliation(s)
- Zain I. Sharif
- Cardiac Arrhythmia Service, Massachusetts General Hospital, Boston, Massachusetts
| | - Steven A. Lubitz
- Cardiac Arrhythmia Service, Massachusetts General Hospital, Boston, Massachusetts
- Cardiovascular Research Center, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
6
|
Raffel DM, Crawford TC, Jung YW, Koeppe RA, Gu G, Rothley J, Frey KA. Quantifying cardiac sympathetic denervation: first studies of 18F-fluorohydroxyphenethylguanidines in cardiomyopathy patients. Eur J Nucl Med Mol Imaging 2021; 49:619-631. [PMID: 34387718 DOI: 10.1007/s00259-021-05517-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 07/29/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE 4-18F-Fluoro-m-hydroxyphenethylguanidine (18F-4F-MHPG) and 3-18F-fluoro-p-hydroxyphenethylguanidine (18F-3F-PHPG) were developed for quantifying regional cardiac sympathetic nerve density using tracer kinetic analysis. The aim of this study was to evaluate their performance in cardiomyopathy patients. METHODS Eight cardiomyopathy patients were scanned with 18F-4F-MHPG and 18F-3F-PHPG. Also, regional resting perfusion was assessed with 13N-ammonia. 18F-4F-MHPG and 18F-3F-PHPG kinetics were analyzed using the Patlak graphical method to obtain Patlak slopes Kp (mL/min/g) as measures of regional nerve density. Patlak slope polar maps were used to evaluate the pattern and extent of cardiac denervation. For comparison, "retention index" (RI) values (mL blood/min/mL tissue) were also calculated and used to assess denervation. Perfusion polar maps were used to estimate the extent of hypoperfusion. RESULTS Patlak analysis of 18F-4F-MHPG and 18F-3F-PHPG kinetics was successful in all subjects, demonstrating the robustness of this approach in cardiomyopathy patients. Substantial regional denervation was observed in all subjects, ranging from 25 to 74% of the left ventricle. Denervation zones were equal to or larger than the size of corresponding areas of hypoperfusion. The two tracers provided comparable metrics of regional nerve density and the extent of left ventricular denervation. 18F-4F-MHPG exhibited faster liver clearance than 18F-3F-PHPG, reducing spillover from the liver into the inferior wall. 18F-4F-MHPG was also metabolized more consistently in plasma, which may allow application of population-averaged metabolite corrections. CONCLUSION The advantages of 18F-4F-MHPG (more rapid liver clearance, more consistent metabolism in plasma) make it the better imaging agent to carry forward into future clinical studies in patients with cardiomyopathy. TRIAL REGISTRATION Registered at the ClinicalTrials.gov website (NCT02669563). URL: https://clinicaltrials.gov/ct2/show/NCT02669563.
Collapse
Affiliation(s)
- David M Raffel
- Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, 2276 Medical Science I, 1301 Catherine St., Ann Arbor, MI, 48109-5610, USA.
| | - Thomas C Crawford
- Division of Cardiology, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI, 48109, USA
| | - Yong-Woon Jung
- Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, 2276 Medical Science I, 1301 Catherine St., Ann Arbor, MI, 48109-5610, USA
| | - Robert A Koeppe
- Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, 2276 Medical Science I, 1301 Catherine St., Ann Arbor, MI, 48109-5610, USA
| | - Guie Gu
- Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, 2276 Medical Science I, 1301 Catherine St., Ann Arbor, MI, 48109-5610, USA
| | - Jill Rothley
- Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, 2276 Medical Science I, 1301 Catherine St., Ann Arbor, MI, 48109-5610, USA
| | - Kirk A Frey
- Division of Nuclear Medicine, Department of Radiology, University of Michigan Medical School, 2276 Medical Science I, 1301 Catherine St., Ann Arbor, MI, 48109-5610, USA
| |
Collapse
|
7
|
Deo R, Pothineni NVK. The "Shocking" Reality of ICD Therapies. J Am Coll Cardiol 2021; 77:2463-2465. [PMID: 34016258 DOI: 10.1016/j.jacc.2021.04.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 04/12/2021] [Indexed: 11/25/2022]
Affiliation(s)
- Rajat Deo
- Electrophysiology Section, Division of Cardiovascular Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA.
| | - Naga Venkata K Pothineni
- Electrophysiology Section, Division of Cardiovascular Medicine, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
8
|
Goto K, Ono Y, Osaka Y, Kurihara K, Otomo K, Sasano T. A sustained ventricular tachycardia overlooked by subcutaneous implantable cardioverter-defibrillator but recognized by co-implanted transvenous implantable cardioverter defibrillator. HeartRhythm Case Rep 2020; 6:334-337. [PMID: 32577389 PMCID: PMC7300333 DOI: 10.1016/j.hrcr.2020.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
9
|
Ayinde H, Lloyd M. A review of specialized and automated features in implantable cardiac devices. J Cardiovasc Electrophysiol 2019; 31:271-285. [PMID: 31724786 DOI: 10.1111/jce.14276] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 10/26/2019] [Accepted: 11/07/2019] [Indexed: 11/30/2022]
Abstract
Automated features available in cardiac implantable electronic devices continue to increase in number and complexity. These features are frequently confused with device malfunction and often result in unnecessary clinical attention. This review will serve as an update to some of the more commonly-encountered features discussed in terms of the behavior they exhibit.
Collapse
Affiliation(s)
- Hakeem Ayinde
- Section of Clinical Cardiac Electrophysiology, Emory University Hospital, Atlanta, Georgia
| | - Michael Lloyd
- Section of Clinical Cardiac Electrophysiology, Emory University Hospital, Atlanta, Georgia
| |
Collapse
|
10
|
Shenasa M, Heidary S, Shenasa H. Inappropriate ICD shock due to hot tub-induced external electrical interference. J Electrocardiol 2018; 51:852-855. [PMID: 30177327 DOI: 10.1016/j.jelectrocard.2018.06.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 06/01/2018] [Accepted: 06/26/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND A 72-year-old white male with a history of rapid nonsustained ventricular tachycardia, hypertrophic cardiomyopathy, and intermittent Brugada-type ECG had a single-lead implantable cardioverter-defibrillator (ICD) implantation and received a sudden ICD shock while in the hot tub. To the best of our knowledge this is the first case report of hot tub jet-induced inappropriate ICD shock. METHODS ICD interrogation and analysis of intracardiac electrograms and event markers. RESULTS ICD interrogation revealed inappropriate ICD shocks due to electrical interference of hot tub engine; 60-cycle electrical artifact mimicking fast ventricular fibrillation erroneously detected by the device. The device then delivered a 34.8 joules shock while the patient was actually in sinus rhythm. CONCLUSIONS Electrical interference due to external sources such as hot tub engines may occur and produce an inappropriate detection and ICD shock. Precaution and patient education is warranted.
Collapse
Affiliation(s)
- Mohammad Shenasa
- Heart & Rhythm Medical Group, San Jose, CA 95128, USA; O'Connor Hospital, San Jose, CA 95128, USA.
| | - Shahriar Heidary
- Heart & Rhythm Medical Group, San Jose, CA 95128, USA; O'Connor Hospital, San Jose, CA 95128, USA
| | - Hossein Shenasa
- Heart & Rhythm Medical Group, San Jose, CA 95128, USA; O'Connor Hospital, San Jose, CA 95128, USA
| |
Collapse
|
11
|
Inappropriate ICD Discharge Related to Electrical Muscle Stimulation in Chiropractic Therapy: A Case Report. Cardiol Ther 2017; 6:139-143. [PMID: 28258389 PMCID: PMC5446819 DOI: 10.1007/s40119-017-0086-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Indexed: 12/13/2022] Open
Abstract
Implantable cardioverter defibrillators (ICDs) have been shown to reduce mortality in high-risk patients. Despite several advances in programming ICDs, inappropriate shocks persist and continue to be psychologically and physically disturbing. External electromagnetic interference from electrocautery, welding, acupunctures, low-output transcutaneous electric nerve stimulators, and electronic muscle stimulators may result in inappropriate ICD sensing and shock. We present a 63-year-old female who presented to the emergency department after an ICD shock while undergoing electronic muscle stimulation in chiropractic treatment, during which light electrical pulses were sent through skin electrodes. Our case highlights the importance of recognizing methods used by alternative medicine doctors, including electrical muscle stimulation that may cause electromagnetic interference and inappropriate ICD discharge and therefore, a higher overall mortality risk.
Collapse
|
12
|
Hwang KW, Nam GB, Han J, Kim YG, Choi HO, Kim J, Choi KJ, Kim YH. Incidence of Atrial Tachyarrhythmias in Patients With Early Repolarization Syndrome. Int Heart J 2017; 58:43-49. [PMID: 28077816 DOI: 10.1536/ihj.16-104] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Atrial tachyarrhythmias (ATAs) occur in a significant proportion of Brugada syndrome (BrS) patients and are often an important cause of inappropriate shocks. The aim of this retrospective study was to evaluate the incidence of ATAs and ATA-induced inappropriate shocks in early repolarization syndrome (ERS) patients as compared to BrS patients.We analyzed data from 20 consecutive patients who were diagnosed with ERS and compared them with patients diagnosed with BrS (n = 31). Clinical and ICD interrogation data were collected and analyzed for all events with ICD shocks.Three patients had a history of atrial fibrillation (AF) prior to ICD implantation. One patient had AV reentrant tachycardia and was successfully ablated before ICD implantation. ATAs were newly diagnosed in 4 patients with no prior history of AF. There were no significant differences in gender, age, or left atrial diameter between ATA development. Four (20%) of 20 consecutive patients received inappropriate ICD shocks for ATAs. One suffered from repeat inappropriate shocks triggered by paroxysmal AF and received catheter ablation for AF.ATAs were not infrequent in patients with ERS and seemed to be related to inappropriate ICD therapy. Careful ICD programming is required to reduce ATA-related inappropriate ICD shock in patients with ERS.
Collapse
Affiliation(s)
- Ki Won Hwang
- Division of Cardiology, Department of Internal Medicine, Pusan National University Yangsan Hospital, Pusan National University of Medicine
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Park KH, Lee CH, Jung BC, Cho Y, Bae MH, Kim YN, Park HS, Han S, Lee YS, Hyun DW, Kim J, Kim DK, Cha TJ, Shin DG. Effectiveness of Implantable Cardioverter-Defibrillator Therapy for Heart Failure Patients according to Ischemic or Non-Ischemic Etiology in Korea. Korean Circ J 2016; 47:72-81. [PMID: 28154594 PMCID: PMC5287190 DOI: 10.4070/kcj.2016.0242] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2016] [Revised: 08/25/2016] [Accepted: 09/13/2016] [Indexed: 11/20/2022] Open
Abstract
Background and Objectives This study was performed to describe clinical characteristics of patients with left ventriculars (LV) dysfunction and implantable cardioverter-defibrillator (ICD), and to evaluate the effect of ICD therapy on survival in Yeongnam province of Korea. Subjects and Methods From a community-based device registry (9 centers, Yeongnam province, from November 1999 to September 2012), 146 patients with LV dysfunction and an ICD implanted for primary or secondary prophylaxis, were analyzed. The patients were divided into two groups, based on the etiology (73 with ischemic cardiomyopathy and 73 with non-ischemic cardiomyopathy), and indication for the device implantation (36 for primary prevention and 110 for secondary prevention). The cumulative first shock rate, all cause death, and type and mode of death, were determined according to the etiology and indication. Results Over a mean follow-up of 3.5 years, the overall ICD shock rate was about 39.0%. ICD shock therapy was significantly more frequent in the secondary prevention group (46.4% vs. 16.7%, p=0.002). The cumulative probability of a first appropriate shock was higher in the secondary prevention group (p=0.015). There was no significant difference in the all-cause death, cardiac death, and mode of death between the groups according to the etiology and indication. Conclusion Studies from this multicenter regional registry data shows that in both ischemic and non-ischemic cardiomyopathy patients, the ICD shock therapy rate was higher in the secondary prevention group than primary prevention group.
Collapse
Affiliation(s)
- Kyu-Hwan Park
- Division of Cardiology, Department of Internal Medicine, Yeungnam University Medical Center, Daegu, Korea
| | - Chan-Hee Lee
- Division of Cardiology, Department of Internal Medicine, Yeungnam University Medical Center, Daegu, Korea
| | - Byung Chun Jung
- Division of Cardiology, Department of Internal Medicine, Daegu Fatima Hospital, Daegu, Korea
| | - Yongkeun Cho
- Division of Cardiology, Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea
| | - Myung Hwan Bae
- Division of Cardiology, Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea
| | - Yoon-Nyun Kim
- Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, Korea
| | - Hyoung-Seob Park
- Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, Korea
| | - Seongwook Han
- Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, Korea
| | - Young Soo Lee
- Division of Cardiology, Department of Internal Medicine, Catholic University Medical Center, Daegu, Korea
| | - Dae-Woo Hyun
- Cardiovascular Center, Andong Medical Group, Andong, Korea
| | - Jun Kim
- Division of Cardiology, Department of Internal Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Dae Kyeong Kim
- Division of Cardiology, Department of Internal Medicine, Inje University Busan Paik Hospital, Busan, Korea
| | - Tae-Jun Cha
- Division of Cardiology, Department of Internal Medicine, Kosin University Gospel Hospital, Busan, Korea
| | - Dong-Gu Shin
- Division of Cardiology, Department of Internal Medicine, Yeungnam University Medical Center, Daegu, Korea
| |
Collapse
|
14
|
Very high rate programming in primary prevention patients with reduced ejection fraction implanted with a defibrillator: Results from a large multicenter controlled study. Heart Rhythm 2016; 14:211-217. [PMID: 27989789 DOI: 10.1016/j.hrthm.2016.10.024] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Indexed: 11/24/2022]
Abstract
BACKGROUND Programming implantable cardioverter-defibrillators (ICDs) with a high-rate therapy strategy has proven to be effective in reducing shocks and is associated with a reduced mortality. OBJECTIVE We sought to determine the impact of a very high rate cutoff programming strategy on outcomes in patients with a primary indication for an ICD due to reduced left ventricular ejection fraction. METHODS Using data from the multicenter French DAI-PP registry, this cohort-controlled study compared outcomes in 500 patients programmed with a very high rate cutoff (VH-RATE group: monitor zone 170-219 beats/min; ventricular fibrillation zone ≥220 beats/min with 13 ± 4 detection intervals) with 1500 matched control patients programmed with 1 or 2 therapy zone. All ICDs were implanted for primary prevention in patients with systolic dysfunction. Risks of events were compared after propensity score matching of sex, age, ejection fraction, New York Heart Association class, cardiomyopathy, atrial fibrillation, and type of device. RESULTS After a mean follow-up of 3.6 ± 2.3 years, VH-RATE programming was associated with a reduction of appropriate therapy risk (hazard ratio [HR] 0.40; 95% confidence interval [CI] 0.31-0.51; P < .0001) and inappropriate shock (HR 0.42; 95% CI 0.27-0.63; P < .0001). It was also associated with a decreased risk of sudden cardiac death (HR 0.43; 95% CI 0.17-0.99; P = .04) as compared with patients programmed with 2 therapy zones. There was no significant difference in overall survival between the groups. CONCLUSION In patients implanted with an ICD in primary prevention with left ventricular dysfunction, very high rate cutoff programming (single therapy zone ≥220 beats/min) was associated with a 60% reduction of appropriate therapies as well as inappropriate shocks, without affecting mortality.
Collapse
|
15
|
Cardoso RN, Healy C, Viles-Gonzalez J, Coffey JO. ICD discrimination of SVT versus VT with 1:1 V-A conduction: A review of the literature. Indian Pacing Electrophysiol J 2016; 15:236-44. [PMID: 27134440 PMCID: PMC4834441 DOI: 10.1016/j.ipej.2016.02.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Inappropriate ICD shocks are associated with increased mortality. They also impair patients' quality of life, increase hospitalizations, and raise health-care costs. Nearly 80% of inappropriate ICD shocks are caused by supraventricular tachycardia. Here we report the case of a patient who received a single-lead dual-chamber sensing ICD for primary prevention of sudden cardiac death and experienced inappropriate ICD shocks. V-A time, electrogram morphology, and response to antitachycardia pacing suggested atrioventricular nodal reentry tachycardia, which was confirmed in an electrophysiology study. Inspired by this case, we performed a literature review to discuss mechanisms for discrimination of supraventricular tachycardia with 1:1 A:V relationship from ventricular tachycardia with 1:1 retrograde conduction.
Collapse
Affiliation(s)
- Rhanderson N Cardoso
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| | - Chris Healy
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| | - Juan Viles-Gonzalez
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| | - James O Coffey
- Cardiovascular Division, Department of Medicine, University of Miami, Miller School of Medicine, Miami, USA
| |
Collapse
|
16
|
Atreya AR, Cook JR, Lindenauer PK. Complications arising from cardiac implantable electrophysiological devices: review of epidemiology, pathogenesis and prevention for the clinician. Postgrad Med 2016; 128:223-30. [DOI: 10.1080/00325481.2016.1151327] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
17
|
Wilkoff BL, Fauchier L, Stiles MK, Morillo CA, Al-Khatib SM, Almendral J, Aguinaga L, Berger RD, Cuesta A, Daubert JP, Dubner S, Ellenbogen KA, Estes NAM, Fenelon G, Garcia FC, Gasparini M, Haines DE, Healey JS, Hurtwitz JL, Keegan R, Kolb C, Kuck KH, Marinskis G, Martinelli M, McGuire M, Molina LG, Okumura K, Proclemer A, Russo AM, Singh JP, Swerdlow CD, Teo WS, Uribe W, Viskin S, Wang CC, Zhang S. 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. J Arrhythm 2016; 32:1-28. [PMID: 26949427 PMCID: PMC4759125 DOI: 10.1016/j.joa.2015.12.001] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Key Words
- AF, atrial fibrillation
- ATP, antitachycardia pacing
- Bradycardia mode and rate
- CI, confidence interval
- CL, cycle length
- CRT, cardiac resynchronization therapy
- CRT-D, cardiac resynchronization therapy–defibrillator
- DT, defibrillation testing
- Defibrillation testing
- EEG, electroencephalography
- EGM, electrogram
- HF, heart failure
- HR, hazard ratio
- ICD, implantable cardioverter-defibrillator
- Implantable cardioverter-defibrillator
- LV, left ventricle
- LVEF, left ventricular ejection fraction
- MI, myocardial infarction
- MVP, managed ventricular pacing
- NCDR, National Cardiovascular Data Registry
- NYHA, New York Heart Association
- OR, odds ratio
- PEA, peak endocardial acceleration
- PVC, premature ventricular contraction
- Programming
- RCT, randomized clinical trial
- RV, right ventricle
- S-ICD, subcutaneous implantable cardioverter-defibrillator
- SCD, sudden cardiac death
- SVT, supraventricular tachycardia
- TIA, transient ischemic attack
- Tachycardia detection
- Tachycardia therapy
- VF, ventricular fibrillation
- VT, ventricular tachycardia (Heart Rhythm 2015;0:1–37)
- aCRT, adaptive cardiac resynchronization therapy
Collapse
Affiliation(s)
| | | | | | - Carlos A Morillo
- Department of Medicine, Cardiology Division, McMaster University-Population Health Research Institute, Hamilton, Canada
| | | | - Jesœs Almendral
- Grupo HM Hospitales, Universidad CEU San Pablo, Madrid, Spain
| | | | | | - Alejandro Cuesta
- Servicio de Arritmias, Instituto de Cardiologia Infantil, Montevideo, Uruguay
| | | | - Sergio Dubner
- Clinica y Maternidad Suizo Argentina; De Los Arcos Sanatorio, Buenos Aires, Argentina
| | | | | | | | - Fermin C Garcia
- Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - David E Haines
- William Beaumont Hospital Division of Cardiology, Royal Oak, Michigan
| | - Jeff S Healey
- Department of Medicine, Cardiology Division, McMaster University-Population Health Research Institute, Hamilton, Canada
| | | | | | | | | | | | | | | | - Luis G Molina
- Mexico's National University, Mexico's General Hospital, Mexico City, Mexico
| | - Ken Okumura
- Hirosaki University Graduate School of Medicine, Hirosaki, Aomori, Japan
| | - Alessandro Proclemer
- Azienda Ospedaliero Universitaria S. Maria della Misericordia- Udine, Udine, Italy
| | | | - Jagmeet P Singh
- Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | | | - Wee Siong Teo
- National Heart Centre Singapore, Singapore, Singapore
| | - William Uribe
- CES Cardiología and Centros Especializados San Vicente Fundación, Medellín y Rionegro, Colombia
| | - Sami Viskin
- Tel Aviv Sourasky Medical Center and Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | | | - Shu Zhang
- National Center for Cardiovascular Disease and Beijing Fu Wai Hospital, Peking Union Medical College and China Academy of Medical Sciences, Beijing, China
| |
Collapse
|
18
|
John RM, Stevenson W. Current Management of Ventricular Tachycardia: Approaches and Timing. CARDIOVASCULAR INNOVATIONS AND APPLICATIONS 2016. [DOI: 10.15212/cvia.2015.0015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
19
|
2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm 2015; 13:e50-86. [PMID: 26607062 DOI: 10.1016/j.hrthm.2015.11.018] [Citation(s) in RCA: 179] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Indexed: 12/12/2022]
|
20
|
Wilkoff BL, Fauchier L, Stiles MK, Morillo CA, Al-Khatib SM, Almendral J, Aguinaga L, Berger RD, Cuesta A, Daubert JP, Dubner S, Ellenbogen KA, Estes NAM, Fenelon G, Garcia FC, Gasparini M, Haines DE, Healey JS, Hurtwitz JL, Keegan R, Kolb C, Kuck KH, Marinskis G, Martinelli M, Mcguire M, Molina LG, Okumura K, Proclemer A, Russo AM, Singh JP, Swerdlow CD, Teo WS, Uribe W, Viskin S, Wang CC, Zhang S. 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Europace 2015; 18:159-83. [PMID: 26585598 DOI: 10.1093/europace/euv411] [Citation(s) in RCA: 97] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
21
|
Sandgren E, Rorsman C, Engdahl J, Edvardsson N. Low rate of and rapid attention to inappropriate ICD shocks with remote device and rhythm monitoring: a qualitative study. Open Heart 2015; 2:e000249. [PMID: 26244099 PMCID: PMC4521515 DOI: 10.1136/openhrt-2015-000249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2015] [Revised: 07/01/2015] [Accepted: 07/03/2015] [Indexed: 11/21/2022] Open
Abstract
Objectives Inappropriate shocks are unpleasant and painful. We hypothesise that remote monitoring and careful attention to known and incident atrial fibrillation (AF) can reduce inappropriate shocks to a very low level in clinical praxis. Methods Altogether 259 patients with implantable cardioverter defibrillator implanted for secondary (S, n=113) and primary (P, n=146) prevention were followed via remote monitoring. At implant, 42S (37%) and 54P (37%) patients had known AF. Results Inappropriate shocks, all but five due to AF, occurred in 7S (6.2%) and 11P (7.5%), and there were only inappropriate shocks in 5/7S and in 8/11P. They occurred in four of 42S (9.5%) with and in three of 71S (4.2%) without known AF, and in seven of 54P (13%) with and in four of 92P (4.3%) without known AF. The median time from shock to action was 5 and 1 day, respectively. Actions were medication with amiodarone, β blockers, β blockers+amiodarone or β blockers+digoxin (n=5), β blockers+insertion of an atrial lead (n=1), replacement of a fractured lead (n=2), reprogramming in combination with β blockers, digoxin or amiodarone (n=4), reprogramming (n=2) and none (n=4). After action, four further inappropriate shocks occurred during more than 2 years of follow-up, all due to AF. Conclusions Inappropriate shocks occurred at a low rate and most often because of AF known at implant. Remote monitoring enabled rapid action, after which few inappropriate shocks occurred over more than 2 years. Attention to known and incident AF was the most important action to reduce inappropriate shocks.
Collapse
Affiliation(s)
- Emma Sandgren
- Department of Medicine , Halland Hospital , Varberg , Sweden
| | - Cecilia Rorsman
- Department of Medicine , Halland Hospital , Varberg , Sweden
| | - Johan Engdahl
- Department of Medicine , Halland Hospital , Halmstad , Sweden
| | - Nils Edvardsson
- Sahlgrenska Academy , Sahlgrenska University Hospital , Göteborg , Sweden
| |
Collapse
|
22
|
Failure to deliver a shock in a dual-chamber implantable cardioverter-defibrillator: A case report. Rev Port Cardiol 2015; 34:495.e1-5. [DOI: 10.1016/j.repc.2014.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Revised: 11/26/2014] [Accepted: 12/30/2014] [Indexed: 11/23/2022] Open
|
23
|
Failure to deliver a shock in a dual-chamber implantable cardioverter-defibrillator: A case report. REVISTA PORTUGUESA DE CARDIOLOGIA (ENGLISH EDITION) 2015. [DOI: 10.1016/j.repce.2015.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
24
|
Silver MT, Sterns LD, Piccini JP, Joung B, Ching CK, Pickett RA, Rabinovich R, Liu S, Peterson BJ, Lexcen DR. Feedback to providers improves evidence-based implantable cardioverter-defibrillator programming and reduces shocks. Heart Rhythm 2015; 12:545-553. [DOI: 10.1016/j.hrthm.2014.11.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2014] [Indexed: 10/24/2022]
|
25
|
Abstract
Implantable cardioverter-defibrillators (ICD) have become an integral component in the management of children with life-threatening cardiac arrhythmias complicating a variety of different inherited and congenital cardiovascular conditions. Implantation often requires novel approaches and configurations to overcome the size and anatomic limitations posed by many children needing ICDs. While their use has undoubtedly saved many lives, ICD use may be associated with significant morbidity, so detailed case selection and individualised postimplant programming is critical.
Collapse
Affiliation(s)
- Elizabeth S DeWitt
- Division of Cardiac Electrophysiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Dominic J Abrams
- Division of Cardiac Electrophysiology, Boston Children's Hospital, Boston, Massachusetts, USA
| |
Collapse
|
26
|
Bhavnani SP, Giedrimiene D, Coleman CI, Guertin D, Azeem M, Kluger J. The healthcare utilization and cost of treating patients experiencing inappropriate implantable cardioverter defibrillator shocks: a propensity score study. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2014; 37:1315-23. [PMID: 25139346 DOI: 10.1111/pace.12465] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Revised: 04/30/2014] [Accepted: 05/31/2014] [Indexed: 11/30/2022]
Abstract
BACKGROUND Inappropriate shocks (IASs) from implantable cardioverter defibrillators (ICDs) are associated with decreased quality of life, but whether they increase healthcare utilization and treatment costs is unknown. We sought to determine the impact of IASs on subsequent healthcare utilization and treatment costs. METHODS We conducted a case-control analysis of ICD patients at a single institution from 1997 to 2010 and who had ≥12 months of post-ICD implant follow-up. Cases included all patients experiencing an IAS during the first 12 months after implantation. Eligible control patients did not receive a shock of any kind during the 12 months after implantation. Propensity scores based on 36 covariates (area under curve = 0.78) were used to match cases to controls. We compared the rate (occurrences/person year [PY]) of healthcare utilization immediately following IAS to the end of the 12-month follow-up period to the rate in the no-shock group over 12 months of follow-up. We also compared 12-month postimplant treatment (outpatient clinic, emergency room, and hospitalization) costs in both groups. RESULTS A total of 76 patients experiencing ≥1 IAS during the first 12 months after implant (contributing 48 PYs) were matched to 76 no-shock patients (contributing 76 PYs). Cardiovascular (CV)-related clinic visit and hospitalization rates were increased following an IAS compared to those not receiving a shock (4.0 vs 3.3 and 0.7 vs 0.5, respectively, P = 0.02 for both). CV-related emergency room visitation (0.15 vs 0.08) rates were also numerically higher following an IAS, but did not reach statistical significance (P = 0.26). Patients experiencing an IAS accrued greater treatment costs during the 12 months postimplant compared to no-shock patients ($13,973 ± $46,345 vs $6,790 ± $19,091, P = 0.001). CONCLUSION Recipients of IAS utilize the healthcare system more frequently following an IAS than patients not experiencing a shock. This increased utilization results in higher costs of treating IAS patients during the 12 months postimplant.
Collapse
Affiliation(s)
- Sanjeev P Bhavnani
- Division of Cardiology, Section of Arrhythmia Services, Hartford Hospital, Hartford, Connecticut; Scripps Health, Scripps Translational Sciences Institute, La Jolla, California
| | | | | | | | | | | |
Collapse
|
27
|
Hindricks G, Taborsky M, Glikson M, Heinrich U, Schumacher B, Katz A, Brachmann J, Lewalter T, Goette A, Block M, Kautzner J, Sack S, Husser D, Piorkowski C, Søgaard P. Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial. Lancet 2014; 384:583-590. [PMID: 25131977 DOI: 10.1016/s0140-6736(14)61176-4] [Citation(s) in RCA: 502] [Impact Index Per Article: 50.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND An increasing number of patients with heart failure receive implantable cardioverter-defibrillators (ICDs) or cardiac resynchronisation defibrillators (CRT-Ds) with telemonitoring function. Early detection of worsening heart failure, or upstream factors predisposing to worsening heart failure, by implant-based telemonitoring might enable pre-emptive intervention and improve outcomes, but the evidence is weak. We investigated this possibility in IN-TIME, a clinical trial. METHODS We did this randomised, controlled trial at 36 tertiary clinical centres and hospitals in Australia, Europe, and Israel. We enrolled patients with chronic heart failure, NYHA class II-III symptoms, ejection fraction of no more than 35%, optimal drug treatment, no permanent atrial fibrillation, and a recent dual-chamber ICD or CRT-D implantation. After a 1 month run-in phase, patients were randomly assigned (1:1) to either automatic, daily, implant-based, multiparameter telemonitoring in addition to standard care or standard care without telemonitoring. Investigators were not masked to treatment allocation. Patients were masked to allocation unless they were contacted because of telemonitoring findings. Follow-up was 1 year. The primary outcome measure was a composite clinical score combining all-cause death, overnight hospital admission for heart failure, change in NYHA class, and change in patient global self-assessment, for the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT00538356. FINDINGS We enrolled 716 patients, of whom 664 were randomly assigned (333 to telemonitoring, 331 to control). Mean age was 65·5 years and mean ejection fraction was 26%. 285 (43%) of patients had NYHA functional class II and 378 (57%) had NYHA class III. Most patients received CRT-Ds (390; 58·7%). At 1 year, 63 (18·9%) of 333 patients in the telemonitoring group versus 90 (27·2%) of 331 in the control group (p=0·013) had worsened composite score (odds ratio 0·63, 95% CI 0·43-0·90). Ten versus 27 patients died during follow-up. INTERPRETATION Automatic, daily, implant-based, multiparameter telemonitoring can significantly improve clinical outcomes for patients with heart failure. Such telemonitoring is feasible and should be used in clinical practice. FUNDING Biotronik SE & Co. KG.
Collapse
Affiliation(s)
| | - Milos Taborsky
- Department of Internal Medicine I-Cardiology, Faculty of Medicine and Dentistry, Olomouc, Czech Republic
| | | | | | | | - Amos Katz
- Barzilai Medical Center, Ashkelon, Israel
| | | | | | | | | | - Josef Kautzner
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | | | | | | | - Peter Søgaard
- Heart Centre and Clinical Institute, Aalborg University Hospital, Aalborg, Denmark
| |
Collapse
|
28
|
Mastenbroek MH, Pedersen SS, Versteeg H, Doevendans PA, Meine M. State of the art of ICD programming: Lessons learned and future directions. Neth Heart J 2014; 22:415-20. [PMID: 25074477 PMCID: PMC4188844 DOI: 10.1007/s12471-014-0582-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
The lifesaving benefits of implantable cardioverter defibrillator (ICD) therapy are more and more weighted against possible harm (e.g. unnecessary device therapy, procedural complications, device malfunction etc.) which might have adverse effects on patients' perceived health status and quality of life. Hence, there has been an increasing interest in the optimisation of ICD programming to prevent inappropriate and appropriate but unnecessary device therapy. The purpose of the current report is to give an overview of research into the optimisation of ICD programming and present the design of the on-going ENHANCED-ICD study. The ENHANCED-ICD study is a prospective, safety monitoring study enrolling 60 primary and secondary prophylactic ICD patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology(TM), and between 18-80 years of age, were eligible to participate. In all patients a prolonged detection of 60/80 intervals was programmed. The primary objective of the study is to investigate whether enhanced programming to further reduce ICD therapies is safe. The secondary objective is to examine the impact of enhanced programming on (i) antitachycardia pacing and shocks (both appropriate and inappropriate) and (ii) quality of life and distress. The first results of the ENHANCED-ICD study are expected in 2015.
Collapse
Affiliation(s)
- M H Mastenbroek
- Cardiology, Department of Heart and Lung, University Medical Center, Heidelberglaan 100, PO Box 85500, 3584 CX, Utrecht, the Netherlands,
| | | | | | | | | |
Collapse
|
29
|
Larson ER, Porterfield JE, Sagar S, Marmol-Velez J, Panday M, Escobedo D, Michalek J, Ouyang Y, Valvano JW, Pearce JA, Feldman MD. Admittance to detect alterations in left ventricular stroke volume. Heart Rhythm 2014; 11:2075-83. [PMID: 24981870 DOI: 10.1016/j.hrthm.2014.06.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Indexed: 10/25/2022]
Abstract
BACKGROUND Implantable cardioverter-defibrillators monitor intracardiac electrograms (EGMs) to discriminate between ventricular and supraventricular tachycardias. The incidence of inappropriate shocks remains high because of misclassification of the tachycardia in an otherwise hemodynamically stable individual. Coupling EGMs with an assessment of left ventricular (LV) stroke volume (SV) could help in gauging hemodynamics during an arrhythmia and reducing inappropriate shocks. OBJECTIVE The purpose of this study was to use the admittance method to accurately derive LV SV. METHODS Ultrasonic flow probe and LV endocardial crystals were used in canines (n = 12) as the standard for LV SV. Biventricular pacing leads were inserted to obtain admittance measurements. A tetrapolar, complex impedance measurement was made between the Bi-V leads. The real and imaginary components of impedance were used to discard the myocardial component from the blood component to derive instantaneous blood conductance (Gb). Alterations in SV were measured during right ventricular pacing, dopamine infusion, and inferior vena cava occlusion. RESULTS Gb tracks steady-state changes in SV more accurately than traditional magnitude (ie, |Y|, without removal of the muscle signal) during right ventricular pacing and dopamine infusion (P = .004). Instantaneous LV volume also was tracked more accurately by Gb than ∣Y∣ in the subset of subjects that underwent inferior vena cava occlusions (n = 5, P = .025). Finite element modeling demonstrates that admittance shifts more sensitivity of the measurement to the LV blood chamber as the mechanism for improvement (see Online Appendix). CONCLUSION Monitoring LV SV is possible using the admittance method with biventricular pacing leads. The technique could be piggybacked to complement EGMs to determine if arrhythmias are hemodynamically unstable.
Collapse
Affiliation(s)
- Erik R Larson
- Department of Electrical Engineering, University of Texas at Austin, Austin, Texas
| | | | - Sandeep Sagar
- Division of Cardiology, The University of Texas Health Science Center at San Antonio, San Antonio, Texas
| | - Juan Marmol-Velez
- Division of Cardiology, The University of Texas Health Science Center at San Antonio, San Antonio, Texas
| | - Manoj Panday
- Division of Cardiology, The University of Texas Health Science Center at San Antonio, San Antonio, Texas
| | - Daniel Escobedo
- Division of Cardiology, The University of Texas Health Science Center at San Antonio, San Antonio, Texas
| | - Joel Michalek
- Department of Epidemiology and Biostatistics, The University of Texas Health Science Center at San Antonio, San Antonio, Texas
| | - Yongjian Ouyang
- Department of Epidemiology and Biostatistics, The University of Texas Health Science Center at San Antonio, San Antonio, Texas
| | - Jonathan W Valvano
- Department of Electrical Engineering, University of Texas at Austin, Austin, Texas
| | - John A Pearce
- Department of Electrical Engineering, University of Texas at Austin, Austin, Texas
| | - Marc D Feldman
- Admittance Technologies, Austin, Texas; Division of Cardiology, The University of Texas Health Science Center at San Antonio, San Antonio, Texas; Department of Veterans Affairs, South Texas Veterans Health Care System, San Antonio, Texas.
| |
Collapse
|
30
|
Thachil A, Chennapragada S, Calambur N. Inappropriate Detection of a Supraventricular Tachycardia as Dual Tachycardia by the PR Logic™ Algorithm. Indian Pacing Electrophysiol J 2014; 14:161-4. [PMID: 24920872 PMCID: PMC4032784 DOI: 10.1016/s0972-6292(16)30758-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Tachycardia detection and therapy algorithms in Implantable Cardioverter-Defibrillators (ICD) reduce, but do not eliminate inappropriate ICD shocks. Awareness of the pros and cons of a particular algorithm helps to predict its utility in specific situations. We report a case where PR logic™, an algorithm commonly used in currently implanted ICDs to differentiate supraventricular tachycardia (SVT) from ventricular tachycardia resulted in inappropriate detection and shock for an SVT, and discuss several solutions to the problem.
Collapse
|
31
|
Clementy N, Pierre B, Simeon E, Lallemand B, Fauchier L, Babuty D. Programming implantable cardioverter-defibrillators in primary prevention: Higher or later. Arch Cardiovasc Dis 2014; 107:308-18. [DOI: 10.1016/j.acvd.2014.03.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2014] [Accepted: 03/28/2014] [Indexed: 11/16/2022]
|
32
|
De Maria E, Biffi M, Cappelli S, Boriani G. Pacing-induced torsades de pointes after the short-long-short sequence in a patient with a biventricular defibrillator: What is the mechanism? Heart Rhythm 2014; 11:728-31. [DOI: 10.1016/j.hrthm.2013.12.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2013] [Indexed: 11/27/2022]
|
33
|
SANTANGELI PASQUALE, HSIA HENRYH, WANG PAULJ, AL-AHMAD AMIN. Shock-Induced Ventricular Tachycardia: What Is the Mechanism? Pacing Clin Electrophysiol 2014; 37:516-9. [DOI: 10.1111/pace.12244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/25/2013] [Revised: 07/07/2013] [Accepted: 07/11/2013] [Indexed: 11/26/2022]
Affiliation(s)
- PASQUALE SANTANGELI
- Division of Cardiovascular Medicine, Cardiac Arrhythmia Service; Stanford University; Stanford California
| | - HENRY H. HSIA
- Cardiac Arrhythmia Service; San Francisco VA Hospital and UCSF Medical Center; San Francisco California
| | - PAUL J. WANG
- Division of Cardiovascular Medicine, Cardiac Arrhythmia Service; Stanford University; Stanford California
| | - AMIN AL-AHMAD
- Division of Cardiovascular Medicine, Cardiac Arrhythmia Service; Stanford University; Stanford California
| |
Collapse
|
34
|
Chen BW, Liu Q, Wang X, Dang AM. Are dual-chamber implantable cardioverter-defibrillators really better than single-chamber ones? A systematic review and meta-analysis. J Interv Card Electrophysiol 2014; 39:273-80. [DOI: 10.1007/s10840-014-9873-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2013] [Accepted: 01/21/2014] [Indexed: 11/28/2022]
|
35
|
Stevenson WG, Asirvatham S. Fundamental concepts in electrophysiology in cases and reviews. Circ Arrhythm Electrophysiol 2013; 6:e95-100. [PMID: 24347607 DOI: 10.1161/circep.113.001044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- William G Stevenson
- The Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| | | |
Collapse
|
36
|
De Maria E, Cappelli S, Cappato R. Shock efficacy of the entirely subcutaneous defibrillator for termination of spontaneous ventricular fibrillation in Brugada syndrome. Heart Rhythm 2013; 10:1807-9. [DOI: 10.1016/j.hrthm.2013.08.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2013] [Indexed: 10/26/2022]
|
37
|
DeMazumder D, Lake DE, Cheng A, Moss TJ, Guallar E, Weiss RG, Jones SR, Tomaselli GF, Moorman JR. Dynamic analysis of cardiac rhythms for discriminating atrial fibrillation from lethal ventricular arrhythmias. Circ Arrhythm Electrophysiol 2013; 6:555-61. [PMID: 23685539 DOI: 10.1161/circep.113.000034] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Implantable cardioverter-defibrillators (ICDs), the first line of therapy for preventing sudden cardiac death in high-risk patients, deliver appropriate shocks for termination of ventricular tachycardia (VT)/ventricular fibrillation. A common shortcoming of ICDs is imperfect rhythm discrimination, resulting in the delivery of inappropriate shocks for atrial fibrillation (AF). An underexplored area for rhythm discrimination is the difference in dynamic properties between AF and VT/ventricular fibrillation. We hypothesized that the higher entropy of rapid cardiac rhythms preceding ICD shocks distinguishes AF from VT/ventricular fibrillation. METHODS AND RESULTS In a multicenter, prospective, observational study of patients with primary prevention ICDs, 119 patients received shocks from ICDs with stored, retrievable intracardiac electrograms. Blinded adjudication revealed shocks were delivered for VT/ventricular fibrillation (62%), AF (23%), and supraventricular tachycardia (15%). Entropy estimation of only 9 ventricular intervals before ICD shocks accurately distinguished AF (receiver operating characteristic curve area, 0.98; 95% confidence intervals, 0.93-1.0) and outperformed contemporary ICD rhythm discrimination algorithms. CONCLUSIONS This new strategy for AF discrimination based on entropy estimation expands on simpler concepts of variability, performs well at fast heart rates, and has potential for broad clinical application.
Collapse
Affiliation(s)
- Deeptankar DeMazumder
- Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Recommendations for the Programming of Implantable Cardioverter-Defibrillators in New Zealand. Heart Lung Circ 2012; 21:765-77. [DOI: 10.1016/j.hlc.2012.07.017] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2011] [Revised: 07/17/2012] [Accepted: 07/21/2012] [Indexed: 11/23/2022]
|
39
|
Eickholt C, Siekiera M, Kirmanoglou K, Rodenbeck A, Heussen N, Schauerte P, Lichtenberg A, Balzer J, Rassaf T, Perings S, Kelm M, Shin DI, Meyer C. Improvement of left ventricular function under cardiac resynchronization therapy goes along with a reduced incidence of ventricular arrhythmia. PLoS One 2012; 7:e48926. [PMID: 23152822 PMCID: PMC3495960 DOI: 10.1371/journal.pone.0048926] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2012] [Accepted: 10/02/2012] [Indexed: 12/13/2022] Open
Abstract
Objectives The beneficial effects of cardiac resynchronization therapy (CRT) are thought to result from favorable left ventricular (LV) reverse remodeling, however CRT is only successful in about 70% of patients. Whether response to CRT is associated with a decrease in ventricular arrhythmias (VA) is still discussed controversially. Therefore, we investigated the incidence of VA in CRT responders in comparison with non-responders. Methods In this nonrandomized, two-center, observational study patients with moderate-to-severe heart failure, LV ejection fraction (LVEF) ≤35%, and QRS duration >120 ms undergoing CRT were included. After 6 months patients were classified as CRT responders or non-responders. Incidence of VA was compared between both groups by Kaplan-Meier analysis and Cox regression analysis. ROC analysis was performed to determine the aptitude of LVEF cut-off values to predict VA. Results In total 126 consecutive patients (64±11years; 67%male) were included, 74 were classified as responders and 52 as non-responders. While the mean LVEF at baseline was comparable in both groups (25±7% vs. 24±8%; P = 0.4583) only the responder group showed an improvement of LVEF (36±6% vs. 24±7; p<0.0001) under CRT. In total in 56 patients VA were observed during a mean follow-up of 28±14 months, with CRT responders experiencing fewer VA than non-responders (35% vs. 58%, p<0.0061). Secondary preventive CRT implantation was associated with a higher likelihood of VA. As determined by ROC analysis an increase of LVEF by >7% was found to be a predictor of a significantly lower incidence of VA (AUC = 0.606). Conclusions Improvement of left ventricular function under cardiac resynchronization therapy goes along with a reduced incidence of ventricular arrhythmia.
Collapse
Affiliation(s)
- Christian Eickholt
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Marcus Siekiera
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Kiriakos Kirmanoglou
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Astrid Rodenbeck
- Division of Cardiology, Pulmology and Angiology, University Hospital RWTH-Aachen, Aachen, Germany
| | - Nicole Heussen
- Department of Medical Statistics, University Hospital RWTH-Aachen, Aachen, Germany
| | - Patrick Schauerte
- Division of Cardiology, Pulmology and Angiology, University Hospital RWTH-Aachen, Aachen, Germany
| | - Artur Lichtenberg
- Heinrich-Heine-University Duesseldorf, Department of Cardiovascular Surgery, Dusseldorf, Germany
| | - Jan Balzer
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Tienush Rassaf
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Stefan Perings
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Malte Kelm
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Dong-In Shin
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
| | - Christian Meyer
- Heinrich-Heine-University Duesseldorf, Medical Faculty, Department of Cardiology, Pulmology and Angiology, Dusseldorf, Germany
- * E-mail:
| |
Collapse
|
40
|
John RM, Tedrow UB, Koplan BA, Albert CM, Epstein LM, Sweeney MO, Miller AL, Michaud GF, Stevenson WG. Ventricular arrhythmias and sudden cardiac death. Lancet 2012; 380:1520-9. [PMID: 23101719 DOI: 10.1016/s0140-6736(12)61413-5] [Citation(s) in RCA: 145] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Management strategies for ventricular arrhythmias are guided by the risk of sudden death and severity of symptoms. Patients with a substantial risk of sudden death usually need an implantable cardioverter defibrillator (ICD). Although ICDs effectively end most episodes of ventricular tachycardia or ventricular fibrillation and decrease mortality in specific populations of patients, they have inherent risks and limitations. Generally, antiarrhythmic drugs do not provide sufficient protection from sudden death, but do have a role in reducing arrhythmias that cause symptoms. Catheter ablation is likewise important for reducing the frequency of spontaneous arrhythmias and is curative for some patients, usually those with idiopathic arrhythmias and no heart disease. Arrhythmia surgery is now infrequent, offered by only a few specialised centres for refractory arrhythmias. Advances in understanding of genetic arrhythmia syndromes and in technology for mapping and ablation of ventricular arrhythmias, and enhanced algorithms in implantable devices for rhythm management, have contributed to improved outcomes.
Collapse
Affiliation(s)
- Roy M John
- Department of Medicine, Division of Cardiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|