1
|
Teunis T, Sayegh GE, Fatehi A, Ring D, Vagner G, Reichel L. Does lidocaine reduce pain intensity during corticosteroid injection? A double-blind randomized controlled equivalence trial. J Hand Surg Eur Vol 2024; 49:1202-1208. [PMID: 38641946 PMCID: PMC11523541 DOI: 10.1177/17531934241245036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 03/12/2024] [Accepted: 03/16/2024] [Indexed: 04/21/2024]
Abstract
Of the strategies considered to limit the discomfort of corticosteroid injection, one is to inject without lidocaine to reduce the total volume and avoid acidity. In a Bayesian trial, adults receiving corticosteroid injections were randomized to receive 0.5 mL of triamcinolone with or without 0.5 mL of lidocaine. Serial analysis was performed until a 95% probability of presence or absence of a 1.0-point difference in pain intensity on the 0-10 Numerical Rating Scale was reached. Injections with lidocaine were associated with a median of 2.4-point lower pain intensity during injection with a 95% probability of at least a 1-point reduction. The 95% probability was confirmed in 90% of the repeated analysis (36/40). Lidocaine is associated with lower immediate pain intensity during corticosteroid injection for hand and wrist conditions.Level of evidence: I.
Collapse
Affiliation(s)
- Teun Teunis
- Department of Surgery and Perioperative Care Dell Medical School, Austin, TX, USA
| | - George E. Sayegh
- Department of Surgery and Perioperative Care Dell Medical School, Austin, TX, USA
| | - Amir Fatehi
- Department of Surgery and Perioperative Care Dell Medical School, Austin, TX, USA
| | - David Ring
- Department of Surgery and Perioperative Care Dell Medical School, Austin, TX, USA
| | - Gregg Vagner
- Department of Surgery and Perioperative Care Dell Medical School, Austin, TX, USA
| | - Lee Reichel
- Department of Surgery and Perioperative Care Dell Medical School, Austin, TX, USA
| |
Collapse
|
2
|
Akinseye C, Fiorini A, Jarvis EL, Fry M, Raza A, Soleman S, Igwe S, Palmer M. Investigation into the Acceptability of Moderate-to-Large Volume Subcutaneous Injections in Healthy Volunteers: Results from a Single-Center Randomized Controlled Study. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2024; 17:369-384. [PMID: 39479340 PMCID: PMC11522010 DOI: 10.2147/mder.s479507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 10/11/2024] [Indexed: 11/02/2024] Open
Abstract
Purpose Therapeutic proteins are often delivered by subcutaneous (SC) autoinjector to enable self-administration. Autoinjectors typically deliver up to 1 mL injected volumes per dose. Delivery of larger volumes may be limited by injection site discomfort, including pain, swelling, and redness. Delivery at a slower rate may mitigate this discomfort. This single-center, randomized, crossover study evaluated the acceptability and tolerability of varying volumes and delivery rates of SC saline in healthy volunteers. Patients and Methods Eligible participants were adults (18-65 years) with a body mass index of 18.5-32.0 kg/m2. Participants (N = 24) were randomized to multiple sequences of infusions over five visits, with infusions ranging from 1 to 5 mL at rates of 1.50-6.00 mL/minute (min) and including a 1 mL SC infusion in 10 seconds (s) at a rate of 6.00 mL/min. The primary objective was to identify acceptable volume and delivery rates of SC saline, as assessed by visual analogue scale (VAS) pain scores, a tolerability and acceptability questionnaire, and infusion leakage. Results Infusions that met the acceptability criteria were 1 mL in 10s, 4 mL in 58s, and 3 mL in 2 mins. Higher delivery volumes and rates were associated with higher VAS pain scores but remained within the VAS acceptability criteria. Conclusion These findings may support the development of larger-volume injectors for self-administration of future medicines.
Collapse
Affiliation(s)
| | | | | | - Michelle Fry
- GSK Rx Global Clinical Delivery, Stockley Park, UK
| | | | - Sara Soleman
- GSK Clinical Unit, Addenbrooke’s Centre for Clinical Investigation, Cambridge, UK
| | - Stephanie Igwe
- GSK Clinical Unit, Addenbrooke’s Centre for Clinical Investigation, Cambridge, UK
| | | |
Collapse
|
3
|
Abouchaleh N, Bayart C. Strategies to minimize procedure-related pain and anxiety: lessons from pediatric dermatology. Curr Opin Pediatr 2024; 36:406-410. [PMID: 38957126 DOI: 10.1097/mop.0000000000001371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
PURPOSE OF REVIEW Recent studies have suggested that prolonged or repeated episodes of general anesthesia early in childhood may adversely affect neurodevelopment. This, combined with rising healthcare costs and decreasing access, has sparked interest in performing pediatric procedures in the office setting when possible. It is essential to address the physical and psychological discomfort that often accompany this experience, particularly in children. RECENT FINDINGS Healthcare providers performing procedures on children can draw from a spectrum of established techniques, new technology, and novel use of medications to decrease peri-procedural pain and anxiety. These techniques include distraction, optimization of local anesthesia, and mild to moderate sedation. SUMMARY We recommend using a combination of techniques to minimize pain and anxiety to improve safety, decrease healthcare costs, improve patient experience, and prevent childhood trauma and persistent negative perception of the healthcare system.
Collapse
Affiliation(s)
| | - Cheryl Bayart
- Cincinnati Children's Hospital Medical Center, University of Cincinnati-Affiliate, Cincinnati, Ohio, USA
| |
Collapse
|
4
|
Moschetti V, Buschke S, Bertulis J, Hohl K, McCabe D. Relative bioavailability, immunogenicity, and safety of two adalimumab-adbm formulations in healthy volunteers: a double-blind, randomized, single-dose, parallel-arm Phase I trial (VOLTAIRE-HCLF). Expert Opin Biol Ther 2024; 24:673-679. [PMID: 38739422 DOI: 10.1080/14712598.2024.2354902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 05/09/2024] [Indexed: 05/14/2024]
Abstract
OBJECTIVE VOLTAIRE-HCLF compared the relative bioavailability of citrate-free high-concentration and reference formulations of the biosimilar adalimumab-adbm (Cyltezo®), including pharmacokinetic (PK) profiles, immunogenicity, and safety profiles in healthy volunteers. METHODS Healthy volunteers (N = 200) aged 18-55 years and with body mass index of 18.5-29.9 kg/m2 and no prior exposure to adalimumab were randomized in a 1:1 ratio to receive a single subcutaneous injection of either adalimumab-adbm 40 mg/0.4 mL (high-concentration formulation) or 40 mg/0.8 mL (reference formulation). Participants completed 13 follow-up visits over 57 days, followed by a safety follow-up period of up to 70 days. RESULTS The main PK parameters were similar for the high-concentration and reference groups. For all primary endpoints, the geometric mean ratios and 90% confidence intervals of AUC0-1344, AUC0-∞, and Cmax for both groups were entirely within the standard 80-125% bioequivalence acceptance range at 101.88% (93.31-111.23%), 105.38% (95.06-116.81%), and 91.29% (84.38-98.76%), respectively. There were no differences in the proportion of anti-drug antibody-positive participants or in the distribution of anti-drug antibody titers between the two formulations at any time point after drug dosing. Participants who were given the high-concentration formulation of adalimumab-adbm experienced a lower incidence of adverse events and local reactions than those who were given the reference formulation. CONCLUSIONS Overall, the high-concentration and reference adalimumab-adbm formulations had highly similar PK and immunogenicity profiles and were safe and well tolerated. CLINICAL TRIAL REGISTRATION NCT05203289.
Collapse
Affiliation(s)
- Viktoria Moschetti
- Global Clinical Development & Operations, Boehringer Ingelheim Pharma GmbH & Co. KG, Ingelheim am Rhein, Germany
| | - Susanne Buschke
- Clinical Pharmacology, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach/Riss, Germany
| | - Julia Bertulis
- Clinical Pharmacology, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach/Riss, Germany
| | - Kathrin Hohl
- Clinical Pharmacology, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach/Riss, Germany
| | - Dorothy McCabe
- Specialty Medicine, Boehringer Ingelheim Pharmaceuticals, Inc, Ridgefield, CT, USA
| |
Collapse
|
5
|
Ignaut D, Fukuda T, Bandi R, Ermer M, Stoffel MS, Zijlstra E, Paavola C. An Investigation Into Local Infusion Site Pain After Infusion of Ultra Rapid Lispro Excipients Across Sites and Depths. J Diabetes Sci Technol 2024; 18:920-929. [PMID: 36326260 PMCID: PMC11307233 DOI: 10.1177/19322968221135217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND This phase 1, randomized, one-day, five-period crossover study in adults with type 1 diabetes on continuous subcutaneous insulin infusion investigated local infusion site pain following infusion of the excipients of ultra rapid lispro (URLi; without insulin) across infusion sites and depths. METHODS Forty participants (mean age, 40.5 years; body mass index [BMI], 27.5) were randomized to one of five infusion site sequences consisting of the arm, thigh, buttock (6 mm cannula depth), and abdomen (6 and 9 mm depth). Basal infusion of sodium citrate and treprostinil in diluent with magnesium chloride was initiated (10 μL/h) and at three, six, and nine hours after basal initiation, 15 unit-equivalent boluses (150 μL) were given. Participants rated their pain on a 0 to 100 mm validated visual analog scale (VAS) at 5 minutes pre-bolus and 1 and 15 minutes post-bolus. RESULTS At one minute post-bolus, increased VAS scores were occasionally reported. Most one minute post-bolus scores were ≤10 mm (little to no discomfort) while 7 of 577 were >45 mm (generally considered clinically meaningful pain). Painful infusions were reported more frequently for the arm, and mean VAS scores were higher for the arm compared with the thigh and abdomen. The VAS score distributions were similar between cannula depths. By 15 minutes post-bolus, VAS scores returned to pre-bolus levels. CONCLUSIONS Local infusion site discomfort after infusion of URLi excipients was reported by a small subset of participants; it was transient, tolerable, and dependent on infusion site but not infusion depth. Given differences within individuals, patients may consider using a different infusion site if they experience discomfort. CLINICALTRIAL.GOV IDENTIFIER NCT05067270.
Collapse
|
6
|
Mathias N, Huille S, Picci M, Mahoney RP, Pettis RJ, Case B, Helk B, Kang D, Shah R, Ma J, Bhattacharya D, Krishnamachari Y, Doucet D, Maksimovikj N, Babaee S, Garidel P, Esfandiary R, Gandhi R. Towards more tolerable subcutaneous administration: Review of contributing factors for improving combination product design. Adv Drug Deliv Rev 2024; 209:115301. [PMID: 38570141 DOI: 10.1016/j.addr.2024.115301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/21/2024] [Accepted: 03/28/2024] [Indexed: 04/05/2024]
Abstract
Subcutaneous (SC) injections can be associated with local pain and discomfort that is subjective and may affect treatment adherence and overall patient experience. With innovations increasingly focused on finding ways to deliver higher doses and volumes (≥2 mL), there is a need to better understand the multiple intertwined factors that influence pain upon SC injection. As a priority for the SC Drug Development & Delivery Consortium, this manuscript provides a comprehensive review of known attributes from published literature that contribute to pain/discomfort upon SC injection from three perspectives: (1) device and delivery factors that cause physical pain, (2) formulation factors that trigger pain responses, and (3) human factors impacting pain perception. Leveraging the Consortium's collective expertise, we provide an assessment of the comparative and interdependent factors likely to impact SC injection pain. In addition, we offer expert insights and future perspectives to fill identified gaps in knowledge to help advance the development of patient-centric and well tolerated high-dose/high-volume SC drug delivery solutions.
Collapse
Affiliation(s)
- Neil Mathias
- Bristol-Myers Squibb, Co., 1 Squibb Dr, New Brunswick, NJ, 08901 USA
| | - Sylvain Huille
- Sanofi, 13 quai Jules Guesde, 94400 Vitry-Sur-Seine, France.
| | - Marie Picci
- Novartis Pharma AG, Fabrikstrasse 4, CH-4056 Basel, Switzerland
| | - Robert P Mahoney
- Comera Life Sciences, 12 Gill St, Suite 4650, Woburn, MA 01801 USA
| | - Ronald J Pettis
- Becton-Dickinson, 21 Davis Drive, Research Triangle Park, NC 27513 USA
| | - Brian Case
- KORU Medical Systems, 100 Corporate Dr, Mahwah, NJ 07430 USA
| | - Bernhard Helk
- Novartis Pharma AG, Werk Klybeck, WKL-681.4.42, CH-4057 Basel, Switzerland
| | - David Kang
- Halozyme Therapeutics, Inc., 12390 El Camino Real, San Diego, CA 92130 USA
| | - Ronak Shah
- Bristol-Myers Squibb, Co., 1 Squibb Dr, New Brunswick, NJ, 08901 USA
| | - Junchi Ma
- Johnson & Johnson Innovative Medicine, 200 Great Valley Pkwy, Malvern, PA 19355 USA
| | | | | | - Dany Doucet
- GSK, 1250 South Collegeville Road, Collegeville, PA 19426 USA
| | | | - Sahab Babaee
- Merck & Co., Inc., 126 E. Lincoln Ave., Rahway, NJ 07065 USA
| | - Patrick Garidel
- Boehringer Ingelheim Pharma GmbH & Co. KG, Birkendorfer Straße 65, 88397 Biberach/Riss, Germany
| | | | - Rajesh Gandhi
- Bristol-Myers Squibb, Co., 1 Squibb Dr, New Brunswick, NJ, 08901 USA
| |
Collapse
|
7
|
Stevenson J, Poker R, Schoss J, Campbell M, Everitt C, Holly B, Stones N, Pettis RJ, Sanchez-Felix M. Pharmaceutical and biotech industry perspectives on optimizing patient experience and treatment adherence through subcutaneous drug delivery design. Adv Drug Deliv Rev 2024; 209:115322. [PMID: 38677443 DOI: 10.1016/j.addr.2024.115322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Revised: 04/06/2024] [Accepted: 04/19/2024] [Indexed: 04/29/2024]
Abstract
Subcutaneous (SC) drug delivery can be a safe, effective alternative to the traditional intravenous route of administration, potentially offering notable advantages for both patients and healthcare providers. The SC Drug Development & Delivery Consortium convened in 2018 to raise awareness of industry challenges to advance the development of patient-centric SC drug delivery strategies. The SC Consortium identified better understanding of patient preferences and perspectives as necessary to optimize SC product design attributes and help guide design decisions during SC product development. This manuscript provides a comprehensive overview of patient-centric factors for consideration in the SC drug delivery design and development process with the aim of establishing a foundation of existing knowledge for patient experiences related to SC drug delivery. This overview is informed by the outcomes of a multi-step survey of Consortium members and key pharmaceutical stakeholders. Framed in the context of the patient's treatment journey, the survey findings offer future perspectives to fill data gaps to advance patient-centric SC drug delivery.
Collapse
Affiliation(s)
| | - Rachel Poker
- AstraZeneca, Human Factors Engineering, BioPharmaceutical Development, Biopharmaceuticals R&D, 121 Oyster Point Blvd, South San Francisco, CA 94080, USA
| | | | | | - Claire Everitt
- Pfizer, Granta Park, Great Abington, Cambridge CB21 6GP, UK
| | - Brian Holly
- Pfizer, Granta Park, Great Abington, Cambridge CB21 6GP, UK
| | - Nicholas Stones
- Novartis Pharma AG, Lichtstrasse 35, CH-4056 Basel, Switzerland
| | - Ronald J Pettis
- Becton-Dickinson, 21 Davis Drive, Research Triangle Park, NC 27513, USA
| | | |
Collapse
|
8
|
Allegretti JR, Brady JH, Wicker A, Latymer M, Wells A. Relevance of Adalimumab Product Attributes to Patient Experience in the Biosimilar Era: A Narrative Review. Adv Ther 2024; 41:1775-1794. [PMID: 38466559 PMCID: PMC11052875 DOI: 10.1007/s12325-024-02818-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 02/07/2024] [Indexed: 03/13/2024]
Abstract
Adalimumab (ADL, Humira®, reference product), an anti-TNF-α biologic, has transformed the treatment of chronic, immune-mediated inflammatory diseases. However, the high cost of ADL therapy has driven the development of more affordable ADL biosimilars, agents with no clinically meaningful differences from the reference product. This review summarizes the product attributes of reference ADL and the nine ADL biosimilars approved and available in the USA in relation to patient experience of injection-site pain (ISP). Product formulation, delivery volume and device features (e.g., type and needle gauge size) influence patient experience of ISP with potential clinical consequences. Citrate-free formulations generally cause less ISP; injection volumes of > 1.5 ml may be associated with increased ISP. Reference ADL and all ADL biosimilars offer a citrate-free formulation, and reference ADL and four ADL biosimilars offer a high-concentration solution that allows a smaller injection volume. All available ADL products are injected subcutaneously using either a pre-filled pen (PFP) or pre-filled syringe (PFS). Patients prefer the PFP, but the PFS permits better control over the speed and duration of injection. Smaller (29-gauge) needle outer diameter is associated with less ISP; reference ADL and seven ADL biosimilars offer a device with a 29-gauge needle. In the USA, an approved biosimilar can be designated "interchangeable," allowing pharmacy-level substitution, where state law permits. In the USA, two ADL biosimilars have received interchangeability designation; others are seeking interchangeability designation from the Food and Drug Administration (n = 2), are being evaluated in clinical studies to support interchangeability (n = 2), or do not have/are not seeking interchangeability designation (n = 3). Product-related attributes influence patient experience of ISP caused by subcutaneous ADL injection. Reference ADL and ADL biosimilar products differ in their attributes, so discussion with patients about treatment options is essential to optimize adherence and outcomes.
Collapse
Affiliation(s)
- Jessica R Allegretti
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA.
| | | | | | | | - Alvin Wells
- Department of Rheumatology, Advocate Health Medical Group, Franklin, WI, USA
| |
Collapse
|
9
|
Davis JD, Bravo Padros M, Conrado DJ, Ganguly S, Guan X, Hassan HE, Hazra A, Irvin SC, Jayachandran P, Kosloski MP, Lin KJ, Mukherjee K, Paccaly A, Papachristos A, Partridge MA, Prabhu S, Visich J, Welf ES, Xu X, Zhao A, Zhu M. Subcutaneous Administration of Monoclonal Antibodies: Pharmacology, Delivery, Immunogenicity, and Learnings From Applications to Clinical Development. Clin Pharmacol Ther 2024; 115:422-439. [PMID: 38093583 DOI: 10.1002/cpt.3150] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 12/06/2023] [Indexed: 01/11/2024]
Abstract
Subcutaneous (s.c.) administration of monoclonal antibodies (mAbs) can reduce treatment burden for patients and healthcare systems compared with intravenous (i.v.) infusion through shorter administration times, made possible by convenient, patient-centric devices. A deeper understanding of clinical pharmacology principles related to efficacy and safety of s.c.-administered mAbs over the past decade has streamlined s.c. product development. This review presents learnings from key constituents of the s.c. mAb development pathway, including pharmacology, administration variables, immunogenicity, and delivery devices. Restricted mAb transportation through the hypodermis explains their incomplete absorption at a relatively slow rate (pharmacokinetic (PK)) and may impact mAb-cellular interactions and/or onset and magnitude of physiological responses (pharmacodynamic). Injection volumes, formulation, rate and site of injection, and needle attributes may affect PKs and the occurrence/severity of adverse events like injection-site reactions or pain, with important consequences for treatment adherence. A review of immunogenicity data for numerous compounds reveals that incidence of anti-drug antibodies (ADAs) is generally comparable across i.v. and s.c. routes, and complementary factors including response magnitude (ADA titer), persistence over time, and neutralizing antibody presence are needed to assess clinical impact. Finally, four case studies showcase how s.c. biologics have been clinically developed: (i) by implementation of i.v./s.c. bridging strategies to streamline PD-1/PD-L1 inhibitor development, (ii) through co-development with i.v. presentations for anti-severe acute respiratory syndrome-coronavirus 2 antibodies to support rapid deployment of both formulations, (iii) as the lead route for bispecific T cell engagers (BTCEs) to mitigate BTCE-mediated cytokine release syndrome, and (iv) for pediatric patients in the case of dupilumab.
Collapse
Affiliation(s)
- John D Davis
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | | | - Samit Ganguly
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Xiaowen Guan
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Hazem E Hassan
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Anasuya Hazra
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Susan C Irvin
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | | | - Kuan-Ju Lin
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | - Anne Paccaly
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | | | - Saileta Prabhu
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | | | - Erik S Welf
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Xiaoying Xu
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - An Zhao
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| | - Min Zhu
- Regeneron Pharmaceuticals, Inc., Tarrytown, New York, USA
| |
Collapse
|
10
|
Li Z, Du X, Wang YMC. A survey of FDA Approved Monoclonal Antibodies and Fc-fusion Proteins for Manufacturing Changes and Comparability Assessment. Pharm Res 2024; 41:13-27. [PMID: 37910341 DOI: 10.1007/s11095-023-03627-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/16/2023] [Indexed: 11/03/2023]
Abstract
OBJECTIVE Manufacturing changes occur commonly throughout stages of biologics development and may result in product quality attribute changes. As changes in critical quality attributes have the potential to affect clinical safety and efficacy of products, it is imperative to ensure the quality and clinical performance before introducing the after-change products. Thus, we embarked on this project to understand what data have supported the manufacturing changes for licensed products with pre- and post-approval changes. METHODS We surveyed the manufacturing changes of 85 monoclonal antibodies and 10 Fc fusion proteins approved by the Food and Drug Administration as of December 25, 2021. After collecting the type and timing of changes for these products, we investigated the approaches that provided supporting data for the changes. The source documents included reports submitted by applicants and FDA's regulatory reviews. RESULTS Analytical comparability was assessed to support all identified manufacturing changes. Supporting clinical data were available in 92% of these manufacturing changes; including data from pharmacokinetic comparability studies alone (3%), other studies on efficacy or safety (70%) and a combination of both (19%). Clinical pharmacokinetic comparability data contributed to supporting substantial changes, such as host cell type or master cell bank changes, concentration or formulation changes, and changes from pre-filled syringes to autoinjectors, especially when introduced after completing pivotal studies. CONCLUSION Our comprehensive retrospective analysis provides an understanding of the regulatory experience and industry practice, which could facilitate developing appropriate comparability approaches to support manufacturing changes in the future.
Collapse
Affiliation(s)
- Zhe Li
- Office of Clinical Pharmacology, Center for Drug Evaluation and Research, U.S. Food and Drug Administration (OCP/CDER/FDA), 10903 New Hampshire Avenue, Silver Spring, MD, USA.
| | - Xiulian Du
- Office of Clinical Pharmacology, Center for Drug Evaluation and Research, U.S. Food and Drug Administration (OCP/CDER/FDA), 10903 New Hampshire Avenue, Silver Spring, MD, USA
| | - Yow-Ming C Wang
- Office of Clinical Pharmacology, Center for Drug Evaluation and Research, U.S. Food and Drug Administration (OCP/CDER/FDA), 10903 New Hampshire Avenue, Silver Spring, MD, USA
| |
Collapse
|
11
|
Abitbol V, Benkhalifa S, Habauzit C, Marotte H. Navigating adalimumab biosimilars: an expert opinion. J Comp Eff Res 2023; 12:e230117. [PMID: 37855223 PMCID: PMC10690439 DOI: 10.57264/cer-2023-0117] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 09/22/2023] [Indexed: 10/20/2023] Open
Abstract
The patent expiry of Humira® in 2018 opened up the current European market to eight adalimumab biosimilars - (in alphabetical order) Amgevita®, Amsparity®, Hulio®, Hukyndra®, Hyrimoz®, Idacio®, Imraldi® and Yuflyma® - for the treatment of various immune and inflammatory conditions. Amjevita, Hadlima®, Hyrimoz and Yuflyma have recently become available in the USA, with others expected to reach this market in 2023 as the US patent protection for Humira ends. Although adalimumab biosimilars demonstrate efficacy, safety and immunogenicity similar to the originator, they may differ in product excipient(s) and preservatives, along with their device type(s). Physicians may find it both difficult and time consuming to navigate their way among the array of available adalimumab biosimilars when they need to make a treatment decision. This article explores the characteristics of various adalimumab biosimilars to help clinicians navigate the various options available across Europe and the USA. In addition to drug selection, effective patient-physician communication is needed to nurture realistic patient expectations and minimise potential nocebo effects when prescribing biosimilars.
Collapse
Affiliation(s)
- Vered Abitbol
- Service de gastroentérologie, Hôpital Cochin, AP-HP, Université Paris Cité, Paris, 75014, France
| | | | | | - Hubert Marotte
- Université Jean Monnet Saint-Étienne, CHU Saint-Étienne, Service de Rhumatologie, Mines Saint-Etienne, INSERM, SAINBIOSE U1059, Saint-Etienne, 42023, France
| |
Collapse
|
12
|
Yu J, Chen W, Liu Q, Mi J. Investigating 3D-printed disk compressing against skin for pain relief in intradermal infiltration anesthesia: a randomized controlled trial. BMC Anesthesiol 2023; 23:144. [PMID: 37118673 PMCID: PMC10148480 DOI: 10.1186/s12871-023-02088-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 04/10/2023] [Indexed: 04/30/2023] Open
Abstract
BACKGROUND Pain intensity may be varied during the needle advancing through different skin layers, injection into the intradermal layer may exclude mixed pain from deeper planes. This study aimed to investigate whether compressing a three-dimensional (3D)-printed disk against the skin may relieve pain associated with intradermal injection of local anesthetic which mimics the skin test procedure. METHODS After institutional review board approval, 3D-printed disks with projections were designed for this study. Enrolled patients were randomized to receive either a disk compressing against the axillary skin during the intradermal injection of local anesthesia (compressing disk group) or an intradermal injection of local anesthesia without any compression (no compressing disk group). The primary outcomes were pain intensity (100-mm visual analog scale) and satisfaction (5-point Likert scale) as assessed by patients. RESULTS Ninety patients with American Society of Anesthesiologists I-II physical status receiving intradermal local anesthesia prior to an ultrasound-guided axillary approach were included. Eighty-seven patients completed the study, with 44 and 43 patients in disk and no disk groups, respectively. Pain scores were significantly different (P < 0.001) in compressing disk (median, 10; IQR, 5-20) and no compressing disk (median, 30; IQR, 20-40) groups. The median satisfaction score was 5 in both groups. No complications occurred during follow-up. CONCLUSION Compressing a 3D-printed disk against the skin may reduce intradermal needle pain and offers an effective alternative for nerve block induction.
Collapse
Affiliation(s)
- Jiong Yu
- Department of Sports Medicine, Wuxi 9Th People's Hospital Affiliated to Soochow University, Wuxi, Jiangsu, China.
| | - Wenxuan Chen
- Medical College, Soochow University, Suzhou, Jiangsu, China
| | - Qianyuan Liu
- Medical College, Soochow University, Suzhou, Jiangsu, China
| | - Jingyi Mi
- Department of Sports Medicine, Wuxi 9Th People's Hospital Affiliated to Soochow University, Wuxi, Jiangsu, China.
| |
Collapse
|
13
|
Sugumar V, Hayyan M, Madhavan P, Wong WF, Looi CY. Current Development of Chemical Penetration Enhancers for Transdermal Insulin Delivery. Biomedicines 2023; 11:biomedicines11030664. [PMID: 36979643 PMCID: PMC10044980 DOI: 10.3390/biomedicines11030664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 02/09/2023] [Accepted: 02/10/2023] [Indexed: 02/25/2023] Open
Abstract
The use of the transdermal delivery system has recently gained ample recognition due to the ability to deliver drug molecules across the skin membrane, serving as an alternative to conventional oral or injectable routes. Subcutaneous insulin injection is the mainstay treatment for diabetes mellitus which often leads to non-compliance among patients, especially in younger patients. Apart from its invasiveness, the long-term consequences of insulin injection cause the development of physical trauma, which includes lipohypertrophy at the site of administration, scarring, infection, and sometimes nerve damage. Hence, there is a quest for a better alternative to drug delivery that is non-invasive and easily adaptable. One of the potential solutions is the transdermal delivery method. However, the stratum corneum (the top layer of skin) is the greatest barrier in transporting large molecules like insulin. Therefore, various chemical enhancers have been proposed to promote stratum corneum permeability, or they are designed to increase the permeability of the full epidermis, such as the use of ionic liquid, peptides, chemical pre-treatment as well as packaging insulin with carriers or nanoparticles. In this review, the recent progress in the development of chemical enhancers for transdermal insulin delivery is discussed along with the possible mechanistic of action and the potential outlook on the proposed permeation approaches in comparison to other therapeutical drugs
Collapse
Affiliation(s)
- Vaisnevee Sugumar
- School of Medicine, Faculty of Health & Medical Sciences, Taylor’s University, 1 Jalan Taylors, Subang Jaya 47500, Malaysia
| | - Maan Hayyan
- Chemical Engineering Program, Faculty of Engineering & Technology, Muscat University, P.O. Box 550, Muscat P.C.130, Oman
- Correspondence: (M.H.); (W.F.W.); (C.Y.L.)
| | - Priya Madhavan
- School of Medicine, Faculty of Health & Medical Sciences, Taylor’s University, 1 Jalan Taylors, Subang Jaya 47500, Malaysia
- Medical Advancement for Better Quality of Life Impact Lab, Taylor’s University, 1, Jalan Taylors, Subang Jaya 47500, Malaysia
| | - Won Fen Wong
- Department of Medical Microbiology, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia
- Correspondence: (M.H.); (W.F.W.); (C.Y.L.)
| | - Chung Yeng Looi
- Medical Advancement for Better Quality of Life Impact Lab, Taylor’s University, 1, Jalan Taylors, Subang Jaya 47500, Malaysia
- School of Biosciences, Faculty of Health & Medical Sciences, Taylor’s University, Subang Jaya 47500, Malaysia
- Correspondence: (M.H.); (W.F.W.); (C.Y.L.)
| |
Collapse
|
14
|
Schneider A, Kolrep H, Horn HP, Jordi C, Gierig S, Lange J. Understanding patient preferences for handheld autoinjectors versus wearable large-volume injectors. Expert Opin Drug Deliv 2023; 20:273-283. [PMID: 36546325 DOI: 10.1080/17425247.2022.2162037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVE While interest in the use of wearable large-volume injectors for subcutaneous drug delivery is increasing, it remains unclear whether and under what conditions these emerging dosing options are preferred over more frequent but shorter administration of smaller doses using handheld autoinjectors. Therefore, the objective of this study was to examine the characteristics of patients diagnosed with cancer, diabetes, inflammatory and cardiovascular diseases, and treatment attributes that determine device preferences. METHODS Based on a cross-sectional online choice experiment, 191 participants expressed their preferences without being physically exposed to the devices or performing injections. Logistic hierarchical regression models were used to assess which patient characteristics, and how changes in treatment attributes, drive device preferences. RESULTS Participant quality of life reduced the likelihood of preferring wearable large-volume injectors to handheld autoinjectors. Moreover, reducing injection frequency from biweekly to monthly to quarterly injections, and shortening injection duration from 33 to 8 min, significantly increased the likelihood of patients preferring large-volume injectors to autoinjectors (p < 0.001). CONCLUSION The study revealed patient quality of life as predictor of device preference and identified critical inflection points in injection duration and injection frequency, at which patient preferences shift from handheld autoinjectors to wearable large-volume injectors.
Collapse
Affiliation(s)
| | | | | | | | - Sina Gierig
- HFC Human-Factors-Consult GmbH, Berlin, Germany
| | | |
Collapse
|
15
|
Coutant M, Malmkvist J, Kaiser M, Foldager L, Herskin MS. Piglets' acute responses to local anesthetic injection and surgical castration: Effects of the injection method and interval between injection and castration. Front Vet Sci 2022; 9:1009858. [PMID: 36246321 PMCID: PMC9556771 DOI: 10.3389/fvets.2022.1009858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 09/02/2022] [Indexed: 11/13/2022] Open
Abstract
Although applied in some countries, efficacy of local anesthetics based on procaine to mitigate acute responses to piglet castration remains questioned. This paper presents results from a factorial study examining the effects of two methods of injection of a procaine-based drug (intra-funicular, IF, vs. intra-testicular, IT), and four intervals between drug injection and castration (2.5, 5, 10, and 30 min) on acute responses of 3–4 day old piglets. The study involved 597 male piglets, and 13 treatments: surgical castration without anesthesia (CC), local anesthesia followed by castration involving all combinations of injection method and interval, and sham handling separated by the same four intervals (SH). Responses of piglets to drug injection, castration and sham handling were evaluated based on quantification of intra-procedural vocalizations and leg movements, as well as saliva cortisol concentration in samples taken before and after castration. No differences were found between IF and the simpler IT injection method. Intervals of 2.5 or 30 min led to stronger piglet responses than the other intervals. Overall, treatments involving anesthesia led to significantly stronger responses than sham handling, during both injection and castration. All treatments, even sham handling, led to a significant increase in saliva cortisol, with no differences between anesthesia treatments and controls. Based on these results, castration 5–10 min after intra-testicular injection of procaine seems to be preferable as compared to the other treatments tested. However, piglets still showed measurable signs of pain and stress during both injection and castration, while handling alone (including the use of a castration bench) triggered a noticeable stress response. In light of these findings, the overall benefit of the procedure in terms of piglet welfare remains arguable.
Collapse
Affiliation(s)
- Mathilde Coutant
- Department of Animal Science, Aarhus University, Tjele, Denmark
- *Correspondence: Mathilde Coutant
| | - Jens Malmkvist
- Department of Animal Science, Aarhus University, Tjele, Denmark
| | - Marianne Kaiser
- Department of Animal Science, Aarhus University, Tjele, Denmark
| | - Leslie Foldager
- Department of Animal Science, Aarhus University, Tjele, Denmark
- Bioinformatics Research Centre, Aarhus University, Aarhus, Denmark
| | | |
Collapse
|
16
|
Teigen IA, Riaz M, Åm MK, Christiansen SC, Carlsen SM. Vasodilatory effects of glucagon: A possible new approach to enhanced subcutaneous insulin absorption in artificial pancreas devices. Front Bioeng Biotechnol 2022; 10:986858. [PMID: 36213069 PMCID: PMC9532737 DOI: 10.3389/fbioe.2022.986858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 08/25/2022] [Indexed: 11/18/2022] Open
Abstract
Patients with diabetes mellitus type 1 depend on exogenous insulin to keep their blood glucose concentrations within the desired range. Subcutaneous bihormonal artificial pancreas devices that can measure glucose concentrations continuously and autonomously calculate and deliver insulin and glucagon infusions is a promising new treatment option for these patients. The slow absorption rate of insulin from subcutaneous tissue is perhaps the most important factor preventing the development of a fully automated artificial pancreas using subcutaneous insulin delivery. Subcutaneous insulin absorption is influenced by several factors, among which local subcutaneous blood flow is one of the most prominent. We have discovered that micro-doses of glucagon may cause a substantial increase in local subcutaneous blood flow. This paper discusses how the local vasodilative effects of micro-doses of glucagon might be utilised to improve the performance of subcutaneous bihormonal artificial pancreas devices. We map out the early stages of our hypothesis as a disruptive novel approach, where we propose to use glucagon as a vasodilator to accelerate the absorption of meal boluses of insulin, besides using it conventionally to treat hypoglycaemia.
Collapse
Affiliation(s)
- Ingrid Anna Teigen
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
| | - Misbah Riaz
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
- Department of Endocrinology, St. Olav’s Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Marte Kierulf Åm
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
| | - Sverre Christian Christiansen
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
- Department of Endocrinology, St. Olav’s Hospital, Trondheim University Hospital, Trondheim, Norway
| | - Sven Magnus Carlsen
- Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway
- Department of Endocrinology, St. Olav’s Hospital, Trondheim University Hospital, Trondheim, Norway
| |
Collapse
|
17
|
Rini CJ, Roberts BC, Vaidyanathan A, Li A, Klug R, Sherman DB, Pettis RJ. Enabling faster subcutaneous delivery of larger volume, high viscosity fluids. Expert Opin Drug Deliv 2022; 19:1165-1176. [PMID: 36053114 DOI: 10.1080/17425247.2022.2116425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
OBJECTIVES Many current subcutaneous (SC) biologic therapies may require >1 mL volume or have increased viscosity, necessitating new delivery system approaches. This study evaluated 2-mL large-volume autoinjector (LVAI) delivery performance across varying solution viscosities and design inputs to assess the design space and identify configurations that produce practical injection times. METHODS Investigational LVAI delivery duration and volume, depot location, and tissue effects were examined in both air and in vivo models across various pre-filled syringe (PFS) cannula types (27 G Ultra-thin wall [UTW], 27 G special thin wall [STW], or 29 G thin-wall [TW]), drive spring forces (SFLOW or SFHIGH), and Newtonian solutions (2.3-50 centipoise [cP]). RESULTS Within each design configuration, increasing PFS internal diameters and spring forces reduced delivery times, while increasing viscosity increased times. The 27 G UTW PFS/SFHIGH combination achieved shorter delivery times across all injection conditions, with 2 mL in vivo durations <15 seconds at ≤31 cP and routinely <20 seconds at 39 and 51 cP, with nominal and transitory tissue effects. CONCLUSION PFS cannula and spring force combinations can be tailored to achieve various injection durations across viscosities, while UTW PFS enables faster rates to potentially better accommodate human factors during LVAI injection, especially at high viscosity.
Collapse
Affiliation(s)
- Christopher J Rini
- Translational and Clinical Sciences Center of Excellence, BD Technologies and Innovation, Durham, NC, USA
| | - Bruce C Roberts
- Translational and Clinical Sciences Center of Excellence, BD Technologies and Innovation, Durham, NC, USA
| | - Aishwarya Vaidyanathan
- Translational and Clinical Sciences Center of Excellence, BD Technologies and Innovation, Durham, NC, USA
| | | | - Rick Klug
- Translational and Clinical Sciences Center of Excellence, BD Technologies and Innovation, Durham, NC, USA
| | - Douglas B Sherman
- Translational and Clinical Sciences Center of Excellence, BD Technologies and Innovation, Durham, NC, USA
| | - Ronald J Pettis
- Translational and Clinical Sciences Center of Excellence, BD Technologies and Innovation, Durham, NC, USA
| |
Collapse
|
18
|
Chabra S, Gill BJ, Gallo G, Zhu D, Pitou C, Payne CD, Accioly A, Puig L. Ixekizumab Citrate-Free Formulation: Results from Two Clinical Trials. Adv Ther 2022; 39:2862-2872. [PMID: 35449322 PMCID: PMC9022732 DOI: 10.1007/s12325-022-02126-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 03/11/2022] [Indexed: 02/07/2023]
Abstract
Introduction Subcutaneous (SC) injection is a common route of drug administration; however, injection site pain (ISP) might create a negative patient experience. We evaluated ISP, bioequivalence, and overall safety of the citrate-free (CF) formulation of ixekizumab, a high-affinity monoclonal antibody that selectively targets interleukin-17A. Methods Two phase 1, single-blind studies were conducted in healthy participants. The crossover study A (NCT03848403) evaluated pain intensity on injection as measured by visual analog scale of pain (VAS) scores. Subjects (N = 70) were randomized 1:1:1 at the beginning to three possible treatment sequences and received a 1 mL SC injection of the three formulations sequentially in the abdomen on days 1, 8, and 15, respectively. A mixed-effects repeated measures analysis model was used to analyze VAS score by time post-injection. Study B (NCT04259346) evaluated the bioequivalence of a single 80 mg dose of CF formulation compared to the original commercial formulation. Subjects (N = 245) were randomized 1:1 to either commercial or CF formulation and received a single SC injection into the abdomen, arm, or thigh. Results Primary endpoint was achieved in both studies. In study A, least-squares mean (LSM) difference of VAS scores immediately post injection between commercial (n = 61) and CF formulation (n = 63) was − 21.7 (p < 0.0001), indicating a lower degree of pain associated with CF formulation. In study B, bioequivalence of the CF formulation was established as 90% CIs for the ratio of geometric LSM AUC0–tlast, AUC0–∞, and Cmax between treatments were contained within the prespecified limits of 0.8 and 1.25. Except for less ISP in the CF formulation, overall safety profile was comparable. Conclusion Ixekizumab CF formulation proved to be bioequivalent, was associated with less ISP, and had no other notable differences in the safety profile compared to the original commercial formulation. Trail Registration ClinicalTrials.gov identifier NCT03848403, NCT04259346. Video Abstract
Supplementary Information The online version contains supplementary material available at 10.1007/s12325-022-02126-0.
Collapse
|
19
|
Matrikines as mediators of tissue remodelling. Adv Drug Deliv Rev 2022; 185:114240. [PMID: 35378216 DOI: 10.1016/j.addr.2022.114240] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 02/21/2022] [Accepted: 03/26/2022] [Indexed: 11/21/2022]
Abstract
Extracellular matrix (ECM) proteins confer biomechanical properties, maintain cell phenotype and mediate tissue repair (via release of sequestered cytokines and proteases). In contrast to intracellular proteomes, where proteins are monitored and replaced over short time periods, many ECM proteins function for years (decades in humans) without replacement. The longevity of abundant ECM proteins, such as collagen I and elastin, leaves them vulnerable to damage accumulation and their host organs prone to chronic, age-related diseases. However, ECM protein fragmentation can potentially produce peptide cytokines (matrikines) which may exacerbate and/or ameliorate age- and disease-related ECM remodelling. In this review, we discuss ECM composition, function and degradation and highlight examples of endogenous matrikines. We then critically and comprehensively analyse published studies of matrix-derived peptides used as topical skin treatments, before considering the potential for improvements in the discovery and delivery of novel matrix-derived peptides to skin and internal organs. From this, we conclude that while the translational impact of matrix-derived peptide therapeutics is evident, the mechanisms of action of these peptides are poorly defined. Further, well-designed, multimodal studies are required.
Collapse
|
20
|
Stepping Forward to the Next Level: Totality of Evidence for the First High-Concentration Adalimumab Biosimilar, CT-P17. Clin Drug Investig 2022; 42:103-112. [PMID: 35025072 DOI: 10.1007/s40261-021-01107-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/21/2021] [Indexed: 11/03/2022]
Abstract
Biosimilar regulatory evaluation considers the totality of evidence gathered through analytical, non-clinical and clinical studies. CT-P17 is the first high-concentration (100 mg/mL), citrate-free adalimumab biosimilar to receive regulatory approval in Europe for all indications held by reference adalimumab, following comprehensive non-clinical and clinical development programmes. State-of-the art physicochemical and biological methods demonstrated quality, analytical and functional comparability between CT-P17 and reference adalimumab; non-clinical in vivo studies supported biosimilarity. Three phase I and two phase III studies were conducted, with pharmacokinetic equivalence of CT-P17 and reference adalimumab shown in healthy volunteers, and equivalent efficacy demonstrated in patients with rheumatoid arthritis. Safety and immunogenicity profiles were comparable between CT-P17 and reference adalimumab across studies. CT-P17 is available for administration by autoinjector/prefilled pen (AI/PFP), prefilled syringe (PFS) and PFS with needle guard, providing diverse self-injection options for patients. Equivalent pharmacokinetics and comparable overall safety and usability were demonstrated between AI/PFP and PFS devices during the clinical development programme. All CT-P17 devices include fine, 29-gauge needles; combined with the citrate-free, high-concentration formulation, these characteristics reflect the newer reference adalimumab formulation (100 mg/mL) and are associated with reduced injection-site pain. The high-concentration formulation also facilitates treatment delivery via fewer injections. Compared with reference adalimumab, CT-P17 remains stable for longer at room temperature, enhancing ease of storage for patients and healthcare providers. In summary, the totality of evidence supports the biosimilarity of CT-P17 to high-concentration reference adalimumab, and several distinctive features differentiate it from existing adalimumab biosimilars.
Collapse
|
21
|
Taghizadeh B, Jaafari MR, Zarghami N. New insight into the importance of formulation variables on parenteral growth hormone preparations: potential effect on the injection-site pain. Front Endocrinol (Lausanne) 2022; 13:963336. [PMID: 36263321 PMCID: PMC9576007 DOI: 10.3389/fendo.2022.963336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 09/16/2022] [Indexed: 11/16/2022] Open
Abstract
Reducing injection-site pain (ISP) in patients with chronic conditions such as growth hormone deficiency is a valuable strategy to improve patient compliance and therapeutic efficiency. Thus understanding different aspects of pain induction following subcutaneous injection of biotherapeutics and identifying the responsible factors are vital. Here we have discussed the effects of formulation's viscosity, concentration, osmolality, buffering agents, pH, and temperature as well as injection volume, dosing frequency, and different excipients on ISP following subcutaneous injection of commercially available recombinant human growth hormone products. Our literature review found limited available data on the effects of different components of parenteral rhGH products on ISP. This may be due to high cost associated with conducting various clinical trials to assess each excipient in the formulation or to determine the complex interactions of different components and its impact on ISP. Recently, conducting molecular dynamics simulation studies before formulation design has been recommended as an alternative and less-expensive approach. On the other hand, the observed inconsistencies in the available data is mainly due to different pain measurement approaches used in each study. Moreover, it is difficult to translate data obtained from animal studies to human subjects. Despite all these limitations, our investigation showed that components of parenteral rhGH products can significantly contribute to ISP. We suggest further investigation is required for development of long acting, buffer-free, preservative-free formulations. Besides, various excipients are currently being investigated for reducing ISP which can be used as alternatives for common buffers, surfactants or preservatives in designing future rhGH formulations.
Collapse
Affiliation(s)
- Bita Taghizadeh
- Department of Medical Biotechnology, School of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahmoud Reza Jaafari
- Biotechnology Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Pharmaceutical Nanotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Nosratollah Zarghami
- Department of Medical Biotechnology, School of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
- Department of Clinical Biochemistry and Laboratory Medicine, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
- *Correspondence: Nosratollah Zarghami,
| |
Collapse
|
22
|
Popovic J, Geffner ME, Rogol AD, Silverman LA, Kaplowitz PB, Mauras N, Zeitler P, Eugster EA, Klein KO. Gonadotropin-releasing hormone analog therapies for children with central precocious puberty in the United States. Front Pediatr 2022; 10:968485. [PMID: 36268040 PMCID: PMC9577333 DOI: 10.3389/fped.2022.968485] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 08/22/2022] [Indexed: 11/28/2022] Open
Abstract
Gonadotropin-releasing hormone agonists (GnRHa's) are the standard treatment for children with central precocious puberty (CPP). We aim to present data on available GnRHa options with an easy-to-review table and discuss factors that influence treatment selection. Five GnRHa's are currently FDA-approved and prescribed in the US and published data suggest similar safety and efficacy profiles over the first year of treatment. One- and 3-month intramuscular (IM) leuprolide acetate (LA) have long-term safety and efficacy data and allow for flexible dosing. Six-month IM triptorelin pamoate offers a longer duration of treatment, but without long-term efficacy and outcome data. Six-month subcutaneous (SQ) LA combines a SQ route of injection and long duration of action but lacks long-term efficacy and outcome data. The 12-month SQ histrelin acetate implant avoids injections and offers the longest duration of action, but requires a minor surgical procedure with local or general anesthesia. Factors in treatment selection include route of administration, needle size, injection volume, duration of action, and cost. The current GnRHa landscape provides options with varying benefits and risks, allowing physicians and caregivers to select the most appropriate therapy based on the specific needs and concerns of the child and the caregiver. Agents have different advantages and disadvantages for use, with no one agent displaying superiority.
Collapse
Affiliation(s)
- Jadranka Popovic
- Department of Pediatric Endocrinology, Pediatric Institute, Allegheny Health Network, Pittsburgh, PA, United States
| | - Mitchell E Geffner
- Department of Pediatric Endocrinology, Diabetes and Metabolism, The Saban Research Institute, Children's Hospital Los Angeles, Keck School of Medicine of the University of Southern California, Los Angeles, CA, United States
| | - Alan D Rogol
- Department of Pediatric Diabetes and Endocrinology, University of Virginia, Charlottesville, VA, United States
| | - Lawrence A Silverman
- Department of Pediatric Endocrinology, Goryeb Children's Hospital Atlantic Health, Morristown, NJ, United States
| | - Paul B Kaplowitz
- Department of Endocrinology, Children's National Hospital, Washington, DC, United States
| | - Nelly Mauras
- Department of Pediatrics, Nemours Children's Health System, Jacksonville, FL, United States
| | - Philip Zeitler
- Department of Pediatric Endocrinology, University of Colorado School of Medicine, Aurora, CO, United States
| | - Erica A Eugster
- Department of Pediatric Endocrinology, Riley Hospital for Children at Indiana University Health, Indianapolis, IN, United States
| | - Karen O Klein
- Department of Pediatrics, Rady Children's Hospital, University of California, San Diego, San Diego, CA, United States
| |
Collapse
|
23
|
Hindmarsh J, Adelaja M, Abd Latif S, Lee M, Pickard J. Administering esomeprazole subcutaneously via a syringe driver in the palliative demographic: A case series. J Clin Pharm Ther 2021; 47:694-698. [PMID: 34961946 DOI: 10.1111/jcpt.13582] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/05/2021] [Accepted: 11/23/2021] [Indexed: 01/06/2023]
Abstract
WHAT IS KNOWN AND OBJECTIVE Proton pump inhibitors are potent suppressors of gastric acid secretion, and are commonly prescribed in palliative medicine. Despite multiple relevant indications in patients at the end-of-life, their use is often precluded as oral and intravenous administration is frequently inappropriate or not possible. Limited anecdotal evidence suggests proton pump inhibitors may be administered subcutaneously. Our objective was to investigate the tolerability and effectiveness of the administration of esomeprazole as a continuous subcutaneous infusion over 24 h via a syringe driver. METHODS Case series (n = 7) design assessing sequential patients admitted to a specialist inpatient centre for palliative care, who required parenteral proton pump inhibitor therapy. RESULTS AND DISCUSSION Four patients reported complete resolution of dyspeptic and reflux symptoms post commencement of esomeprazole. Two patients developed upper gastrointestinal bleeding, which via observation of vomitus and stools, resolved with the initiation of esomeprazole. A single patient, deemed high risk of gastrointestinal bleeding, was commenced on esomeprazole and no bleeding events occurred. WHAT IS NEW AND CONCLUSION Esomeprazole when administered via a syringe driver over 24 h appears well tolerated and effective for the symptomatic management of dyspepsia and treatment of gastrointestinal bleeding. Overall, this series adds to the limited evidence base for using subcutaneous proton pump inhibitors in the palliative demographic.
Collapse
Affiliation(s)
- Jonathan Hindmarsh
- Specialist Centre for Palliative Care, St. Benedict's Hospice, Sunderland, UK.,Department of Pharmacy, Sunderland Royal Hospital, Sunderland, UK
| | - Mercy Adelaja
- Department of Pharmacy, Sunderland Royal Hospital, Sunderland, UK
| | - Saiful Abd Latif
- Specialist Centre for Palliative Care, St. Benedict's Hospice, Sunderland, UK
| | - Mark Lee
- Specialist Centre for Palliative Care, St. Benedict's Hospice, Sunderland, UK
| | - Jonathan Pickard
- Specialist Centre for Palliative Care, St. Benedict's Hospice, Sunderland, UK
| |
Collapse
|
24
|
Eisenberg S. Subcutaneous Administration: Evolution, Challenges, and the Role of Hyaluronidase. Clin J Oncol Nurs 2021; 25:663-671. [PMID: 34800095 DOI: 10.1188/21.cjon.663-671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND The subcutaneous (SC) route has evolved significantly. More than two dozen chemotherapy and supportive therapies have been approved for use in the oncology setting. Several IV therapies have been approved for the SC route and require a significantly higher volume than historical maximum limits. Differences exist in how these drugs are administered as compared to older chemotherapy agents. OBJECTIVES The purpose of this article is to provide a brief history of the SC route and describe its role in cancer treatment. The use of recombinant hyaluronidase is reviewed within the context of SC monoclonal antibodies. Proper administration techniques and interventions for reducing patient discomfort are discussed. METHODS Sentinel medical texts, pharmacokinetic studies, manufacturer's recommendations, and peer-reviewed articles were examined. FINDINGS The SC route offers several advantages over the oral and IV routes. A clear understanding of anatomical site selection and injection techniques is beneficial for providing requisite patient education.
Collapse
|
25
|
Lange J, Schneider A, Jordi C, Lau M, Disher T. Formative Study on the Wearability and Usability of a Large-Volume Patch Injector. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2021; 14:363-377. [PMID: 34815721 PMCID: PMC8605886 DOI: 10.2147/mder.s337670] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 11/03/2021] [Indexed: 11/23/2022] Open
Abstract
Background The subcutaneous self-administration of biologics using a single large-volume bolus dose requires novel large-volume patch injectors. However, the usability and wearability of such on-body devices has rarely been investigated thus far. Therefore, this formative simulated use experiment studies the overall handling and acceptability in terms of the size and weight of a novel 10 mL large-volume patch injector device platform. Methods Twenty-three participants, including patients and healthcare professionals, simulated two injections with the large-volume patch injector, each lasting 17 min. During the injections, the patient participants performed predefined movements and activities with the on-body devices. Perceived usability and wearability were assessed through observation by the moderator and participant-reported feedback using five-point Likert scales and open-ended interviews. Results All participants successfully completed the simulated injections. Only non-serious usability issues were identified. Users rated the device acceptability in terms of wearability and usability with high ratings. Conclusion The results suggest the safe and effective usage of a novel prefilled large-volume patch injector that enables the subcutaneous delivery of a single bolus dose of up to 10 mL with an injection duration of 15 min. The participants of the simulated use study successfully used the device regardless of the disease state, age, or body size and habitus.
Collapse
Affiliation(s)
- Jakob Lange
- Ypsomed Delivery Systems, Ypsomed AG, Burgdorf, Switzerland
| | | | | | - Michael Lau
- Insight Product Development, Chicago, IL, USA
| | | |
Collapse
|
26
|
Woodley WD, Morel DR, Sutter DE, Pettis RJ, Bolick NG. Clinical Evaluation of Large Volume Subcutaneous Injection Tissue Effects, Pain, and Acceptability in Healthy Adults. Clin Transl Sci 2021; 15:92-104. [PMID: 34268888 PMCID: PMC8742644 DOI: 10.1111/cts.13109] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 06/14/2021] [Accepted: 06/16/2021] [Indexed: 11/30/2022] Open
Abstract
Determining feasibility and tolerability of large volume viscous subcutaneous injection may enable optimized, intuitive delivery system design. A translational early feasibility clinical study examined large volume subcutaneous injection viability, tolerability, acceptability, tissue effects and depot location for ~1, 8, and 20 cP injections at volumes up to 10 ml in the abdomen and 5 ml in the thigh in 32 healthy adult subjects. A commercial syringe pump system delivered 192 randomized, constant rate (20 µl/s) injections (6/subject) with in‐line injection pressure captured versus time. Deposition location was qualified via ultrasound. Tissue effects and pain tolerability were monitored through 2 hours post‐injection with corresponding Likert acceptability questionnaires administered through 72 hours. All injection conditions were feasible and well‐tolerated with ≥79.3% favorable subject responses for injection site appearance and sensation immediately post‐injection, increasing to ≥96.8% at 24 hours. Mean subject pain measured via 100 mm visual analog scale increased at needle insertion (6.9 mm, SD 10.8), peaked during injection (26.9 mm, SD 21.7) and diminished within 10 minutes post‐removal (1.9 mm, SD 4.2). Immediate injection site wheal (90.9%) and erythema (92.6%) formation was observed with progressive although incomplete resolution through 2 hours (44.6% and 11.4% remaining, respectively). Wheal resolution occurred more rapidly at lower viscosities. Most subjects (64.5%) had no preference between abdomen and thigh. Correlations between tissue effects, injection pressure and pain were weak (Pearson’s rho ± 0–0.4). The large volume injections tested, 1–20 cP viscosities up to 10 ml in the abdomen and 5 ml in the thigh, are feasible with good subject acceptability and rapid resolution of tissue effects and pain.
Collapse
Affiliation(s)
- Wendy D Woodley
- BD Technologies & Innovation, Research Triangle Park, NC, USA
| | - Didier R Morel
- BD Medical- Pharmaceutical Systems, Le Pont de Claix, France
| | - Diane E Sutter
- BD Technologies & Innovation, Research Triangle Park, NC, USA
| | - Ronald J Pettis
- BD Technologies & Innovation, Research Triangle Park, NC, USA
| | | |
Collapse
|
27
|
Strickley RG, Lambert WJ. A review of Formulations of Commercially Available Antibodies. J Pharm Sci 2021; 110:2590-2608.e56. [PMID: 33789155 DOI: 10.1016/j.xphs.2021.03.017] [Citation(s) in RCA: 115] [Impact Index Per Article: 38.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 03/18/2021] [Accepted: 03/23/2021] [Indexed: 01/08/2023]
Abstract
This review identified 126 commercially available antibodies approved globally between 1986 and February 2021 including 10 antibody drug conjugates, 16 biosimilars, and 3 antibody fragments. Prior to 2014 there were ≤ 5 approved each year, but after 2014 there have been ≥ 7 approved each year with the years 2017, 2019 and 2020 having the most at 17 each. A total of 136 products were identified of which 36 are lyophilized powders and 100 are solutions. The routes of administration are mainly subcutaneous or intravenous infusion with three intravenous bolus, two intravitreal, and one intramuscular. The subcutaneous products are ready-to-use solutions or reconstituted lyophilized powders that do not require dilution while most intravenous products are concentrates that require dilution into saline or another intravenous fluid prior to infusion. Most are packaged in single-dose units and the exception of multi-use is Herceptin® and its biosimilars. The package configurations are vials, prefilled autoinjectors, or prefilled syringes. A typical antibody formulation contains an antibody, an excipient to adjust tonicity or osmolality for solutions or a lyoprotectant for lyophilized powders, a buffer, and a surfactant. The ionic tonicity-adjusting excipient is mainly sodium chloride and the non-ionic osmolality-adjusting excipients include sucrose, trehalose, mannitol, maltose, and sorbitol. The lyoprotectants are trehalose and sucrose. The pH range is 4.8-8.0 and the buffers or pH-modifying agents include histidine, citrate, succinate, acetate, phosphate, glutamate, adipic acid, aspartic acid, lactic acid, tromethamine, and 2-(N-morpholino)-ethanesulfonic acid. The surfactants include mostly polysorbate 20 or polysorbate 80, with four containing poloxamer 188, and one that does not contain a surfactant but contains PEG 3350. One product does not contain a buffer, and 12 do not contain a surfactant. The viscosity-lowering excipients are sodium chloride and the amino acids arginine, glycine, proline, and lysine. Arginine may also function to adjust ionic strength and minimize aggregation. Human serum albumin is used in 2 products for intravenous infusion. Other excipients include methionine as an anti-oxidant, and EDTA or DTPA as chelating agents. The maximum volume of subcutaneous injection is 15 mL administered over 3-5 minutes, but the typically volume is 0.5-2 mL. Five fixed-dose combinations have recently been approved and four contain hyaluronidase to assist the large volume subcutaneous injection of up to 15 mL, while one is a fixed-dose combination for intravenous with three antibodies. Prefilled autoinjectors and syringes are becoming more common and many come affixed with a needle of 27-gauge or 29-gauge, while a few have a 26-gauge or a 30-gauge needle. Recent advancements include hyaluronidase to assist the large subcutaneous injection volume of 5-15 mL, fixed-dose combinations, buffer-free formulation, and smaller subcutaneous injection volume (0.1 mL).
Collapse
Affiliation(s)
- Robert G Strickley
- Pliant Therapeutics, Inc., 160 Littlefield Ave, South San Francisco, CA 94020, United States.
| | - William J Lambert
- Module 3 Pharmaceutical Consulting, P.O. Box 3032, Incline Village, NV 89450, United States.
| |
Collapse
|
28
|
Immunogenicity Challenges Associated with Subcutaneous Delivery of Therapeutic Proteins. BioDrugs 2021; 35:125-146. [PMID: 33523413 PMCID: PMC7848667 DOI: 10.1007/s40259-020-00465-4] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/20/2020] [Indexed: 12/12/2022]
Abstract
The subcutaneous route of administration has provided convenient and non-inferior delivery of therapeutic proteins compared to intravenous infusion, but there is potential for enhanced immunogenicity toward subcutaneously administered proteins in a subset of patients. Unwanted anti-drug antibody response toward proteins or monoclonal antibodies upon repeated administration is shown to impact the pharmacokinetics and efficacy of multiple biologics. Unique immunogenicity challenges of the subcutaneous route have been realized through various preclinical and clinical examples, although subcutaneous delivery has often demonstrated comparable immunogenicity to intravenous administration. Beyond route of administration as a treatment-related factor of immunogenicity, certain product-related risk factors are particularly relevant to subcutaneously administered proteins. This review attempts to provide an overview of the mechanism of immune response toward proteins administered subcutaneously (subcutaneous proteins) and comments on product-related risk factors related to protein structure and stability, dosage form, and aggregation. A two-wave mechanism of antigen presentation in the immune response toward subcutaneous proteins is described, and interaction with dynamic antigen-presenting cells possessing high antigen processing efficiency and migratory activity may drive immunogenicity. Mitigation strategies for immunogenicity are discussed, including those in general use clinically and those currently in development. Mechanistic insights along with consideration of risk factors involved inspire theoretical strategies to provide antigen-specific, long-lasting effects for maintaining the safety and efficacy of therapeutic proteins.
Collapse
|
29
|
Badkar AV, Gandhi RB, Davis SP, LaBarre MJ. Subcutaneous Delivery of High-Dose/Volume Biologics: Current Status and Prospect for Future Advancements. DRUG DESIGN DEVELOPMENT AND THERAPY 2021; 15:159-170. [PMID: 33469268 PMCID: PMC7812053 DOI: 10.2147/dddt.s287323] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 12/15/2020] [Indexed: 12/15/2022]
Abstract
Subcutaneous (SC) delivery of biologics has traditionally been limited to fluid volumes of 1-2 mL, with recent increases to volumes of about 3 mL. This injection volume limitation poses challenges for high-dose biologics, as these formulations may also require increased solution concentration in many cases, resulting in high viscosities which can affect the stability, manufacturability, and delivery/administration of therapeutic drugs. Currently, there are technologies that can help to overcome these challenges and facilitate the delivery of larger amounts of drug through the SC route. This can be achieved either by enabling biologic molecules to be formulated or delivered as high-concentration injectables (>100 mg/mL for antibodies) or through facilitating the delivery of larger volumes of fluid (>3 mL). The SC Drug Delivery and Development Consortium, which was established in 2018, aims to identify and address critical gaps and issues in the SC delivery of high-dose/volume products to help expand this delivery landscape. Identified as a high priority out of the Consortium's eight problem statements, it highlights the need to shift perceptions of the capabilities of technologies that enable the SC delivery of large-volume (>3 mL) and/or high-dose biologics. The Consortium emphasizes a patient-focused approach towards the adoption of SC delivery of large-volume/high-concentration dosing products to facilitate the continued expansion of the capabilities of novel SC technologies. To raise awareness of the critical issues and gaps in high-dose/volume SC drug development, this review article provides a generalized overview of currently available and emerging technologies and devices that could facilitate SC delivery of high-dose/volume drug formulations. In addition, it discusses the challenges, gaps, and future outlook in high-dose/volume SC delivery as well as potential solutions to exploit the full value of the SC route of administration.
Collapse
Affiliation(s)
- Advait V Badkar
- Pharmaceutical Research & Development, Pfizer Inc., Andover, MA, USA
| | - Rajesh B Gandhi
- Drug Product Science & Technology, Bristol-Myers Squibb, Co., New Brunswick, NJ, USA
| | - Shawn P Davis
- BioPharmaceuticals Development, Research & Development, AstraZeneca, Cambridge, MA, UK
| | | |
Collapse
|
30
|
Evaluation of safety and immunogenicity of feline vaccines with reduced volume. Vaccine 2021; 39:1051-1057. [PMID: 33485645 DOI: 10.1016/j.vaccine.2021.01.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 01/06/2021] [Accepted: 01/09/2021] [Indexed: 12/20/2022]
Abstract
A non adjuvanted vaccine against feline herpesvirus, feline calicivirus, feline panleucopenia and feline leukemia has been formulated in reduced volume (0.5 ml) with the same antigen content as the conventional 1 ml presentation. This paper reports studies evaluating the safety and the immunogenicity of this reduced volume vaccine in comparison with the conventional volume vaccine. The safety of both vaccines was evaluated in a small sized laboratory trial. It was further tested in a randomized controlled field trial on a total of 398 cats. Immediate and delayed local and systemic adverse events were monitored after vaccination. The immunogenicity of each vaccine was also checked by serological antibody responses against the vaccines antigens during the laboratory trial. These studies showed that the 0.5 ml vaccine was well tolerated in cats, inducing less local events, while keeping the same immunogenicity as the corresponding 1 ml vaccine. Reducing the volume of the vaccine is a way to improve the convenience of administration and to help following vaccination guidelines with the aim of reducing the incidence of adverse events following vaccination.
Collapse
|
31
|
Skade L, Kristensen CS, Nielsen MBF, Diness LH. Effect of two methods and two anaesthetics for local anaesthesia of piglets during castration. Acta Vet Scand 2021; 63:1. [PMID: 33407757 PMCID: PMC7789362 DOI: 10.1186/s13028-020-00566-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 12/06/2020] [Indexed: 11/23/2022] Open
Abstract
Background Since January 2019, surgical castration of male piglets must be performed using local anaesthesia, if farmers deliver pigs to the primary exporting slaughterhouses according to the “Danish quality scheme”; a voluntary initiative taken by the Danish pig industry. The approved procedure for local anaesthesia in Denmark is a three-step injection method with procaine. A comparison of lidocaine and procaine with the same concentration and injection methods of local anaesthetics has not previously been studied. The purpose of this study was to investigate the effect of two injection methods and two local anaesthetics on piglets’ avoidance behaviour (vocalisation and resistance movements) as well as the time spent on the procedures. The study included 203 male piglets that were randomly assigned to one of five treatments: 1. Control: Sham-handling without injection of local anaesthesia, 2. Pro3: Procaine injection using a three-step method, 3. Pro2: Procaine injection using a two-step method, 4. Lid3: Lidocaine injection using a three-step method, 5. Lid2: Lidocaine injection using a two-step method. During injection of local anaesthesia and castration, vocalisation was measured using a decibel meter and resistance movements were registrated by video recordings. Results During castration, piglets treated with local anaesthesia showed significantly reduced vocalisation and resistance movements and time spent on castration was also significantly reduced compared to the control group. During injection of the local anaesthesia, the piglets had significantly increased vocalisation and resistance movements compared to the control group. Piglets injected with lidocaine had a significantly reduced resistance movement score and a tendency to reduced vocalisation compared to piglets injected with procaine. No differences in avoidance behaviour were found between the injection methods. Conclusions The use of local anaesthesia, irrespective of the method and local anaesthetic, was effective in reducing vocalisation and resistance movements during surgery as well as the time spent on castration.
Collapse
|
32
|
St Clair-Jones A, Prignano F, Goncalves J, Paul M, Sewerin P. Understanding and Minimising Injection-Site Pain Following Subcutaneous Administration of Biologics: A Narrative Review. Rheumatol Ther 2020; 7:741-757. [PMID: 33206343 PMCID: PMC7672413 DOI: 10.1007/s40744-020-00245-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 10/03/2020] [Indexed: 02/07/2023] Open
Abstract
Injection-site pain (ISP) is a subjective side effect that is commonly reported with the subcutaneous administration of biological agents, yet it may only be a concern to some. Multiple factors related to the product formulation, such as pH, volume and excipients, and/or to the injection process have the potential to contribute to ISP, while patient-related factors, such as low body weight, gender and age, can make an individual more susceptible to experiencing ISP. While total elimination of ISP remains unlikely with any subcutaneously administered agent, it can be minimised by helping the patient to develop a confident and competent injection technique via robust and effective training. Careful management of patient expectations along with open discussion regarding the potential risk of ISP may serve to minimise treatment-related anxieties and, importantly, allow the patient to remain in control of his/her treatment. Other interventions to help minimise ISP include psychological interventions, allowing biologics to reach room temperature prior to injection, using the most suitable injection device for the individual patient and selecting an alternative drug formulation, when available. Productive patient–physician communication remains important in order to support and optimise treatment experience and adherence, while also providing the opportunity for patients to discuss any ISP-related issues.
Collapse
Affiliation(s)
- Anja St Clair-Jones
- Pharmacy Department, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK.
| | - Francesca Prignano
- Section of Dermatology, Department of Health Science, University of Florence, Florence, Italy
| | - Joao Goncalves
- iMed-Research Institute for Medicines, Faculdade de Farmácia, Universidade de Lisboa, Lisbon, Portugal
| | - Muriel Paul
- Department of Pharmacy, AP-HP, Henri-Mondor Hospital, Créteil, France
- University of Paris-Est Créteil, Epidemiology in Dermatology and Evaluation of Therapeutics (EpidermE), EA 7379, UPEC, Créteil, 94010, France
| | - Philipp Sewerin
- Department and Hiller Research Unit of Rheumatology, University Clinic Düsseldorf (UKD), Heinrich Heine University, Düsseldorf, Germany
| |
Collapse
|
33
|
de Carellán Mateo AG, Álvarez ER, Ros C. Comparison of the efficacy of 2 sedative protocols in pediatric dogs undergoing brainstem auditory-evoked response testing. THE CANADIAN VETERINARY JOURNAL = LA REVUE VETERINAIRE CANADIENNE 2020; 61:1175-1180. [PMID: 33149355 PMCID: PMC7560758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
This study compared the quality of sedation with dexmedetomidine or alfaxalone during brainstem auditory-evoked response (BAER) tests in 6- to 17-week-old dogs. This was a prospective, randomized clinical study involving 19 client-owned pediatric dogs of breeds with reported congenital deafness. Group A (GA) received alfaxalone, 2 mg/kg body weight (BW) (n = 9) and group D (GD) dexmedetomidine, 0.005 mg/kg BW, and postprocedure antagonism with atipamezole (n = 10) intramuscularly. Time from injection to sedation, duration of sedation, sedation scores, need for re-dosing, rectal temperature, pulse and respiratory rate were recorded at baseline, before and after the BAER test, and once recovered from sedation. Pulse rate was significantly lower in GD (P = 0.004) and the number of re-dosing was significantly higher in GA (P = 0.011). Both sedation protocols allowed good quality BAER test recordings in pediatric dogs. Sedation with dexmedetomidine required less re-dosing, whereas alfaxalone maintained more physiological pulse rates.
Collapse
Affiliation(s)
- Alejandra García de Carellán Mateo
- Departamento de Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Católica de Valencia, San Vicente Mártir, Valencia, Spain (García de Carellán Mateo, Ros); Hospital Veterinario Universidad Católica de Valencia San Vicente Mártir, Avenida Pérez Galdós 51, Valencia, Spain. PC: 46018 (Ríos Álvarez)
| | - Elena Ríos Álvarez
- Departamento de Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Católica de Valencia, San Vicente Mártir, Valencia, Spain (García de Carellán Mateo, Ros); Hospital Veterinario Universidad Católica de Valencia San Vicente Mártir, Avenida Pérez Galdós 51, Valencia, Spain. PC: 46018 (Ríos Álvarez)
| | - Carlos Ros
- Departamento de Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Católica de Valencia, San Vicente Mártir, Valencia, Spain (García de Carellán Mateo, Ros); Hospital Veterinario Universidad Católica de Valencia San Vicente Mártir, Avenida Pérez Galdós 51, Valencia, Spain. PC: 46018 (Ríos Álvarez)
| |
Collapse
|
34
|
Pager A, Combedazou A, Guerrero K, Tzvetkova-Chevolleau T, Morel D, Frolet C, Glezer S. User experience for manual injection of 2 mL viscous solutions is enhanced by a new prefillable syringe with a staked 8 mm ultra-thin wall needle. Expert Opin Drug Deliv 2020; 17:1485-1498. [PMID: 32700596 DOI: 10.1080/17425247.2020.1796630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES User experience was compared between a new pre-fillable 2.25 mL glass syringe equipped with an ultra-thin-wall (UTW) 8 mm staked needle and a marketed BD Neopak™ syringe equipped with a special-thin-wall (STW) 12.7 mm staked needle. METHODS Participants simulated subcutaneous injections with both syringes alone (formative Human Factors study) and in combination with a needlestick-prevention device (validation Human Factors study). RESULTS Usability results of both studies showed higher success rates for delivering the full dose of 2 mL viscous solution (30 cP) with the 8mmUTW syringe than with the 12.7mmSTW one (63% vs. 42% in the formative study). The use of the 8mmUTW syringe demonstrated also better ease of use and acceptance results and 72% of formative study participants preferred this new syringe over the current one when delivering the viscous solution. Using a shorter needle also showed a benefit in decreasing the injection-related anxiety. Besides, in the case of a non-recommended injection technique, the calculated risk of accidental intramuscular injection is reduced by 2 to 13 times with the 8mmUTW syringe. CONCLUSION Altogether, the results obtained demonstrated an improvement of the user experience with this new syringe compared to the current one in the manual delivery of 2 mL viscous solutions.
Collapse
Affiliation(s)
- Aurélie Pager
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company , Le Pont De Claix, France
| | - Anne Combedazou
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company , Le Pont De Claix, France
| | - Karen Guerrero
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company , Le Pont De Claix, France
| | | | - Didier Morel
- Global Clinical Development, Becton Dickinson and Company , Le Pont De Claix, France
| | - Cécile Frolet
- BD Medical - Pharmaceutical Systems, Becton Dickinson and Company , Le Pont De Claix, France
| | - Stanislav Glezer
- Diabetes Care, Becton Dickinson and Company , Franklin Lakes, NJ, USA
| |
Collapse
|
35
|
Rahnfeld L, Luciani P. Injectable Lipid-Based Depot Formulations: Where Do We Stand? Pharmaceutics 2020; 12:E567. [PMID: 32575406 PMCID: PMC7356974 DOI: 10.3390/pharmaceutics12060567] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 06/13/2020] [Accepted: 06/15/2020] [Indexed: 01/18/2023] Open
Abstract
The remarkable number of new molecular entities approved per year as parenteral drugs, such as biologics and complex active pharmaceutical ingredients, calls for innovative and tunable drug delivery systems. Besides making these classes of drugs available in the body, injectable depot formulations offer the unique advantage in the parenteral world of reducing the number of required injections, thus increasing effectiveness as well as patient compliance. To date, a plethora of excipients has been proposed to formulate depot systems, and among those, lipids stand out due to their unique biocompatibility properties and safety profile. Looking at the several long-acting drug delivery systems based on lipids designed so far, a legitimate question may arise: How far away are we from an ideal depot formulation? Here, we review sustained release lipid-based platforms developed in the last 5 years, namely oil-based solutions, liposomal systems, in situ forming systems, solid particles, and implants, and we critically discuss the requirements for an ideal depot formulation with respect to the used excipients, biocompatibility, and the challenges presented by the manufacturing process. Finally, we delve into lights and shadows originating from the current setups of in vitro release assays developed with the aim of assessing the translational potential of depot injectables.
Collapse
Affiliation(s)
| | - Paola Luciani
- Pharmaceutical Technology Research Group, Department of Chemistry and Biochemistry, University of Bern, Freiestrasse 3, 3012 Bern, Switzerland;
| |
Collapse
|
36
|
Zamora JM, Kong JM. Case Series of U-500 Insulin Use in Adults With Type 2 Diabetes and Severe Insulin Resistance. Can J Diabetes 2020; 45:55-58. [PMID: 32847768 DOI: 10.1016/j.jcjd.2020.05.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 05/08/2020] [Accepted: 05/11/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVES Severe insulin resistance results in large volumes of insulin to achieve glycemic control. These large volumes can result in patient discomfort and decreased satisfaction. Using the more concentrated U-500 insulin provides a solution to this problem. This case series demonstrates real-world use of U-500 insulin in a Canadian population. METHODS Seventeen patients were identified to have been started on U-500 insulin at an endocrinology clinic in Vancouver, British Columbia, Canada. The retrospective chart review looked at patients' characteristics before starting U-500 insulin and at their 1-year follow-up appointment. RESULTS At follow up, patients demonstrated improved glycated hemoglobin with a mean improvement of 1.6% at 1 year (p<0.05). There was a statistically significant increase in hypoglycemia (p<0.05), and, on average, patients gained 5.6 kg over the course of the year (p<0.05). There was no statistically significant change in number of units of insulin, injections, lipids, renal function or blood pressure. CONCLUSIONS The initiation of U-500 insulin results in improved glycemic control at the cost of increased hypoglycemia and weight gain.
Collapse
Affiliation(s)
- Jacob M Zamora
- Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada; Division of Endocrinology and Metabolism, Department of Medicine, Vancouver General Hospital, Vancouver, British Columbia, Canada.
| | - Jason M Kong
- Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada; Division of Endocrinology and Metabolism, Department of Medicine, Vancouver General Hospital, Vancouver, British Columbia, Canada
| |
Collapse
|
37
|
Accelerating the development of novel technologies and tools for the subcutaneous delivery of biotherapeutics. J Control Release 2020; 321:475-482. [DOI: 10.1016/j.jconrel.2020.02.036] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 02/21/2020] [Accepted: 02/23/2020] [Indexed: 01/04/2023]
|
38
|
A Phase I Study to Assess the Effect of Speed of Injection on Pain, Tolerability, and Pharmacokinetics After High-volume Subcutaneous Administration of Gantenerumab in Healthy Volunteers. Clin Ther 2020; 42:108-120.e1. [DOI: 10.1016/j.clinthera.2019.11.015] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 11/15/2019] [Accepted: 11/20/2019] [Indexed: 11/20/2022]
|
39
|
Schneider A, Mueller P, Jordi C, Richard P, Sneeringer P, Nayyar R, Yovanoff M, Lange J. Hold the device against the skin: the impact of injection duration on user’s force for handheld autoinjectors. Expert Opin Drug Deliv 2019; 17:225-236. [DOI: 10.1080/17425247.2020.1704730] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
40
|
Usach I, Martinez R, Festini T, Peris JE. Subcutaneous Injection of Drugs: Literature Review of Factors Influencing Pain Sensation at the Injection Site. Adv Ther 2019; 36:2986-2996. [PMID: 31587143 PMCID: PMC6822791 DOI: 10.1007/s12325-019-01101-6] [Citation(s) in RCA: 133] [Impact Index Per Article: 26.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Indexed: 01/19/2023]
Abstract
The subcutaneous administration route is widely used to administer different types of drugs given its high bioavailability and rapid onset of action. However, the sensation of pain at the injection site might reduce patient adherence. Apart from a direct effect of the drug itself, several factors can influence the sensation of pain: needle features, injection site, volume injected, injection speed, osmolality, viscosity and pH of formulation, as well as the kind of excipients employed, including buffers and preservatives. Short and thin needles, conveniently lubricated and with sharp tips, are generally used to minimize pain, although the anatomic injection site (abdomen versus thigh) also affects the sensation of pain. Large subcutaneous injection volumes are associated with pain. In this sense, the maximum volume generally accepted is around 1.5 ml, although volumes of up to 3 ml are well tolerated when injected in the abdomen. Injected volumes of up to 0.5–0.8 ml are not expected to increase substantially the pain produced by the needle insertion. Ideally, injectable products should be formulated as isotonic solutions (osmolality of about 300 mOsm/kg) and no more than 600 mOs/kg have to be used in order to prevent pain. A pH close to the physiological one is recommended to minimize pain, irritation, and tissue damage. Buffers are frequently added to parenteral formulations to optimize solubility and stability by adjusting the pH; however, their strength should be kept as low as possible to avoid pain upon injection. The data available recommend the concentration of phosphate buffer be limited to 10 mM and that the concentration of citrate buffer should be lower than 7.3 mM to avoid an increased sensation of pain. In the case of preservatives, which are required in multiple-dose preparations, m-cresol seems to be more painful than benzyl alcohol and phenol. Funding: Sandoz SA.
Collapse
Affiliation(s)
- Iris Usach
- Department of Pharmacy and Pharmaceutical Technology and Parasitology, Faculty of Pharmacy, University of Valencia, Valencia, Spain
| | - Rafael Martinez
- Department of Medical Affairs, Sandoz SA PE Parque Norte, Edificio Roble, C/Serrano Galvache, Madrid, Spain
| | - Teodora Festini
- Department of Global Medical Affairs, Sandoz Biopharmaceuticals, Holzkirchen, Germany
| | - José-Esteban Peris
- Department of Pharmacy and Pharmaceutical Technology and Parasitology, Faculty of Pharmacy, University of Valencia, Valencia, Spain.
| |
Collapse
|
41
|
Hervé C, Laupèze B, Del Giudice G, Didierlaurent AM, Tavares Da Silva F. The how's and what's of vaccine reactogenicity. NPJ Vaccines 2019; 4:39. [PMID: 31583123 PMCID: PMC6760227 DOI: 10.1038/s41541-019-0132-6] [Citation(s) in RCA: 284] [Impact Index Per Article: 56.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 08/02/2019] [Indexed: 12/12/2022] Open
Abstract
Reactogenicity represents the physical manifestation of the inflammatory response to vaccination, and can include injection-site pain, redness, swelling or induration at the injection site, as well as systemic symptoms, such as fever, myalgia, or headache. The experience of symptoms following vaccination can lead to needle fear, long-term negative attitudes and non-compliant behaviours, which undermine the public health impact of vaccination. This review presents current knowledge on the potential causes of reactogenicity, and how host characteristics, vaccine administration and composition factors can influence the development and perception of reactogenicity. The intent is to provide an overview of reactogenicity after vaccination to help the vaccine community, including healthcare professionals, in maintaining confidence in vaccines by promoting vaccination, setting expectations for vaccinees about what might occur after vaccination and reducing anxiety by managing the vaccination setting.
Collapse
|
42
|
Cohen S, Samad A, Karis E, Stolshek BS, Trivedi M, Zhang H, Aras GA, Kricorian G, Chung JB. Decreased Injection Site Pain Associated with Phosphate-Free Etanercept Formulation in Rheumatoid Arthritis or Psoriatic Arthritis Patients: A Randomized Controlled Trial. Rheumatol Ther 2019; 6:245-254. [PMID: 30915626 PMCID: PMC6514022 DOI: 10.1007/s40744-019-0152-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Indexed: 11/26/2022] Open
Abstract
INTRODUCTION Etanercept, a tumor necrosis factor inhibitor, is used to treat rheumatoid arthritis (RA) and psoriatic arthritis (PsA), and is administered via subcutaneous injection. Injection site pain (ISP) associated with subcutaneous administration may affect compliance or hinder initiation of prescribed medications. To improve the patient experience, a new phosphate-free formulation of etanercept was evaluated for reduced ISP associated with administration. METHODS This phase 3b, multicenter, randomized, double-blind, cross-over study compared the prior formulation of etanercept to a phosphate-free formulation. Etanercept-naïve adults with RA or PsA indicated for treatment with etanercept were eligible. Patients were randomized (1:1) to receive both etanercept formulations (50 mg) in one of two crossover sequences: prior formulation followed by phosphate-free formulation (sequence AB) or phosphate-free formulation followed by prior formulation (sequence BA) at visits 1 week apart. Patients self-reported ISP using a fit-for-purpose 100-mm visual analog scale within 30 s after injection. Safety outcomes included incidence of treatment-emergent adverse events. Mixed-effects analysis of variance model was used to assess ISP, with treatment, study period, sequence, and disease indication as fixed-effect covariates and patient-within-sequence as random effect. RESULTS A total of 111 patients enrolled (56 sequence AB; 55 sequence BA). Mean ISP score for prior formulation was 23.1 mm and for phosphate-free formulation was 19.1 mm (mean difference - 4 mm; 95% confidence interval: - 8.0, 0.0; P = 0.048). Patients with the highest ISP scores from the prior formulation (by quartile cut points) had the largest reduction in pain with phosphate-free formulation. Injection site reactions were few in number and similar between formulations; no new safety signals were observed. CONCLUSIONS The new phosphate-free formulation of etanercept had statistically significantly lower mean pain scores than the prior formulation, with largest pain reductions observed among patients who reported highest pain with the prior formulation. TRIAL REGISTRATION ClinicalTrials.gov: NCT02986139. FUNDING Amgen Inc, Thousand Oaks, CA USA.
Collapse
Affiliation(s)
- Stanley Cohen
- Metroplex Clinical Research Center, Dallas, TX, USA.
| | - Ahmed Samad
- US Medical, Amgen Inc., Thousand Oaks, CA, USA
| | | | | | | | - Hao Zhang
- Biostatistics, Amgen Inc., One Amgen Center Drive, Thousand Oaks, CA, 91320, USA
| | - Girish A Aras
- Biostatistics, Amgen Inc., One Amgen Center Drive, Thousand Oaks, CA, 91320, USA
| | | | | |
Collapse
|
43
|
Hu C, Jia W. Therapeutic medications against diabetes: What we have and what we expect. Adv Drug Deliv Rev 2019; 139:3-15. [PMID: 30529309 DOI: 10.1016/j.addr.2018.11.008] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 09/01/2018] [Accepted: 11/27/2018] [Indexed: 02/06/2023]
Abstract
Diabetes has become one of the largest global health and economic burdens, with its increased prevalence and high complication ratio. Stable and satisfactory blood glucose control are vital to reduce diabetes-related complications. Therefore, continuous attempts have been made in antidiabetic drugs, treatment routes, and traditional Chinese medicine to achieve better disease control. New antidiabetic drugs and appropriate combinations of these drugs have increased diabetes control significantly. Besides, novel treatment routes including oral antidiabetic peptide delivery, nanocarrier delivery system, implantable drug delivery system are also pivotal for diabetes control, with its greater efficiency, increased bioavailability, decreased toxicity and reduced dosing frequency. Among these new routes, nanotechnology, artificial pancreas and islet cell implantation have shown great potential in diabetes therapy. Traditional Chinese medicine also offer new options for diabetes treatment. Our paper aim to overview these therapeutic methods for diabetes therapy. Proper combinations of these existing anti-diabetic medications and searching for novel routes are both necessary for better diabetes control.
Collapse
Affiliation(s)
- Cheng Hu
- Shanghai Diabetes Institute, Shanghai Key Laboratory of Diabetes Mellitus, Shanghai Key Clinical Center for Metabolic Diseases, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, People's Republic of China; Shanghai Jiao Tong University Affiliated Sixth People's Hospital South Campus, 6600 Nanfeng Road, Shanghai 200433, People's Republic of China
| | - Weiping Jia
- Shanghai Diabetes Institute, Shanghai Key Laboratory of Diabetes Mellitus, Shanghai Key Clinical Center for Metabolic Diseases, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, People's Republic of China.
| |
Collapse
|
44
|
Altun İ. May the Z-Tracking Technique to Minimize or Avoid the Pain of Insulin Injection Be an Alternative to the 10-Second Waiting Technique? J Diabetes Sci Technol 2018; 12:731-732. [PMID: 29281892 PMCID: PMC6154241 DOI: 10.1177/1932296817750405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- İnsaf Altun
- Faculty of Health Sciences, Department
of Fundamentals in Nursing, İstinye University, Cevizlibağ, İstanbul, Turkey
- İnsaf Altun, RN, MSN, PhD, Faculty of Health
Sciences, Department of Fundamentals in Nursing, İstinye University, Cevizlibağ,
İstanbul, 34010, Turkey
| |
Collapse
|
45
|
Turner MR, Balu-Iyer SV. Challenges and Opportunities for the Subcutaneous Delivery of Therapeutic Proteins. J Pharm Sci 2018; 107:1247-1260. [PMID: 29336981 PMCID: PMC5915922 DOI: 10.1016/j.xphs.2018.01.007] [Citation(s) in RCA: 89] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 12/21/2017] [Accepted: 01/03/2018] [Indexed: 12/22/2022]
Abstract
Biotherapeutics is a rapidly growing drug class, and over 200 biotherapeutics have already obtained approval, with about 50 of these being approved in 2015 and 2016 alone. Several hundred protein therapeutic products are still in the pipeline, including interesting new approaches to treatment. Owing to patients' convenience of at home administration and reduced number of hospital visits as well as the reduction in treatment costs, subcutaneous (SC) administration of biologics is of increasing interest. Although several avenues for treatment using biotherapeutics are being explored, there is still a sufficient gap in knowledge regarding the interplay of formulation conditions, immunogenicity, and pharmacokinetics (PK) of the absorption of these compounds when they are given SC. This review seeks to highlight the major concerns and important factors governing this route of administration and suggest a holistic approach for effective SC delivery.
Collapse
Affiliation(s)
- Michael R Turner
- Department of Pharmaceutical Sciences, University at Buffalo, The State University of New York, Buffalo, New York 14214
| | - Sathy V Balu-Iyer
- Department of Pharmaceutical Sciences, University at Buffalo, The State University of New York, Buffalo, New York 14214.
| |
Collapse
|