1
|
Haak A, Lesslich HM, Dietzel ID. Visualization of the membrane surface and cytoskeleton of oligodendrocyte progenitor cell growth cones using a combination of scanning ion conductance and four times expansion microscopy. Biol Chem 2024; 405:31-41. [PMID: 37950644 DOI: 10.1515/hsz-2023-0217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 10/17/2023] [Indexed: 11/13/2023]
Abstract
Growth cones of oligodendrocyte progenitor cells (OPCs) are challenging to investigate with conventional light microscopy due to their small size. Especially substructures such as filopodia, lamellipodia and their underlying cytoskeleton are difficult to resolve with diffraction limited microscopy. Light microscopy techniques, which surpass the diffraction limit such as stimulated emission depletion microscopy, often require expensive setups and specially trained personnel rendering them inaccessible to smaller research groups. Lately, the invention of expansion microscopy (ExM) has enabled super-resolution imaging with any light microscope without the need for additional equipment. Apart from the necessary resolution, investigating OPC growth cones comes with another challenge: Imaging the topography of membranes, especially label- and contact-free, is only possible with very few microscopy techniques one of them being scanning ion conductance microscopy (SICM). We here present a new imaging workflow combining SICM and ExM, which enables the visualization of OPC growth cone nanostructures. We correlated SICM recordings and ExM images of OPC growth cones captured with a conventional widefield microscope. This enabled the visualization of the growth cones' membrane topography as well as their underlying actin and tubulin cytoskeleton.
Collapse
Affiliation(s)
- Annika Haak
- Nanoscopy, RUBION, Ruhr-Universität Bochum, Universitätsstraße 150, D-44801 Bochum, Germany
| | - Heiko M Lesslich
- Nanoscopy, RUBION, Ruhr-Universität Bochum, Universitätsstraße 150, D-44801 Bochum, Germany
| | - Irmgard D Dietzel
- Department of Biochemistry II, Electrobiochemistry of Neural Cells, Ruhr-Universität Bochum, D-44801 Bochum, Germany
| |
Collapse
|
2
|
Xu X, Valavanis D, Ciocci P, Confederat S, Marcuccio F, Lemineur JF, Actis P, Kanoufi F, Unwin PR. The New Era of High-Throughput Nanoelectrochemistry. Anal Chem 2023; 95:319-356. [PMID: 36625121 PMCID: PMC9835065 DOI: 10.1021/acs.analchem.2c05105] [Citation(s) in RCA: 34] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Xiangdong Xu
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.
| | | | - Paolo Ciocci
- Université
Paris Cité, ITODYS, CNRS, F-75013 Paris, France
| | - Samuel Confederat
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, U.K.,Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, U.K.
| | - Fabio Marcuccio
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, U.K.,Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, U.K.,Faculty
of Medicine, Imperial College London, London SW7 2AZ, United Kingdom
| | | | - Paolo Actis
- School
of Electronic and Electrical Engineering and Pollard Institute, University of Leeds, Leeds LS2 9JT, U.K.,Bragg
Centre for Materials Research, University
of Leeds, Leeds LS2 9JT, U.K.,
| | | | - Patrick R. Unwin
- Department
of Chemistry, University of Warwick, Coventry CV4 7AL, U.K.,
| |
Collapse
|
3
|
Leitao S, Drake B, Pinjusic K, Pierrat X, Navikas V, Nievergelt AP, Brillard C, Djekic D, Radenovic A, Persat A, Constam DB, Anders J, Fantner GE. Time-Resolved Scanning Ion Conductance Microscopy for Three-Dimensional Tracking of Nanoscale Cell Surface Dynamics. ACS NANO 2021; 15:17613-17622. [PMID: 34751034 PMCID: PMC8613909 DOI: 10.1021/acsnano.1c05202] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Nanocharacterization plays a vital role in understanding the complex nanoscale organization of cells and organelles. Understanding cellular function requires high-resolution information about how the cellular structures evolve over time. A number of techniques exist to resolve static nanoscale structure of cells in great detail (super-resolution optical microscopy, EM, AFM). However, time-resolved imaging techniques tend to either have a lower resolution, are limited to small areas, or cause damage to the cells, thereby preventing long-term time-lapse studies. Scanning probe microscopy methods such as atomic force microscopy (AFM) combine high-resolution imaging with the ability to image living cells in physiological conditions. The mechanical contact between the tip and the sample, however, deforms the cell surface, disturbs the native state, and prohibits long-term time-lapse imaging. Here, we develop a scanning ion conductance microscope (SICM) for high-speed and long-term nanoscale imaging of eukaryotic cells. By utilizing advances in nanopositioning, nanopore fabrication, microelectronics, and controls engineering, we developed a microscopy method that can resolve spatiotemporally diverse three-dimensional (3D) processes on the cell membrane at sub-5-nm axial resolution. We tracked dynamic changes in live cell morphology with nanometer details and temporal ranges of subsecond to days, imaging diverse processes ranging from endocytosis, micropinocytosis, and mitosis to bacterial infection and cell differentiation in cancer cells. This technique enables a detailed look at membrane events and may offer insights into cell-cell interactions for infection, immunology, and cancer research.
Collapse
Affiliation(s)
- Samuel
M. Leitao
- Laboratory
for Bio- and Nano-Instrumentation, Institute of Bioengineering, School
of Engineering, Swiss Federal Institute
of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Barney Drake
- Laboratory
for Bio- and Nano-Instrumentation, Institute of Bioengineering, School
of Engineering, Swiss Federal Institute
of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Katarina Pinjusic
- Laboratory
of Developmental and Cancer Cell Biology, Institute for Experimental
Cancer Research, School of Life Sciences, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Xavier Pierrat
- Laboratory
of Microbial Mechanics, Institute of Bioengineering and Global Health,
School of Life Sciences, Swiss Federal Institute
of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Vytautas Navikas
- Laboratory
of Nanoscale Biology, Institute of Bioengineering, School of Engineering, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Adrian P. Nievergelt
- Laboratory
for Bio- and Nano-Instrumentation, Institute of Bioengineering, School
of Engineering, Swiss Federal Institute
of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Charlène Brillard
- Laboratory
for Bio- and Nano-Instrumentation, Institute of Bioengineering, School
of Engineering, Swiss Federal Institute
of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Denis Djekic
- Institute
of Smart Sensors, Universität Stuttgart, Stuttgart 70049, Germany
| | - Aleksandra Radenovic
- Laboratory
of Nanoscale Biology, Institute of Bioengineering, School of Engineering, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Alexandre Persat
- Laboratory
of Microbial Mechanics, Institute of Bioengineering and Global Health,
School of Life Sciences, Swiss Federal Institute
of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Daniel B. Constam
- Laboratory
of Developmental and Cancer Cell Biology, Institute for Experimental
Cancer Research, School of Life Sciences, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| | - Jens Anders
- Institute
of Smart Sensors, Universität Stuttgart, Stuttgart 70049, Germany
| | - Georg E. Fantner
- Laboratory
for Bio- and Nano-Instrumentation, Institute of Bioengineering, School
of Engineering, Swiss Federal Institute
of Technology Lausanne (EPFL), Lausanne 1015, Switzerland
| |
Collapse
|
4
|
Abstract
Scanning ion conductance microscopy (SICM) has emerged as a versatile tool for studies of interfaces in biology and materials science with notable utility in biophysical and electrochemical measurements. The heart of the SICM is a nanometer-scale electrolyte filled glass pipette that serves as a scanning probe. In the initial conception, manipulations of ion currents through the tip of the pipette and appropriate positioning hardware provided a route to recording micro- and nanoscopic mapping of the topography of surfaces. Subsequent advances in instrumentation, probe design, and methods significantly increased opportunities for SICM beyond recording topography. Hybridization of SICM with coincident characterization techniques such as optical microscopy and faradaic electrodes have brought SICM to the forefront as a tool for nanoscale chemical measurement for a wide range of applications. Modern approaches to SICM realize an important tool in analytical, bioanalytical, biophysical, and materials measurements, where significant opportunities remain for further exploration. In this review, we chronicle the development of SICM from the perspective of both the development of instrumentation and methods and the breadth of measurements performed.
Collapse
Affiliation(s)
- Cheng Zhu
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Kaixiang Huang
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Natasha P Siepser
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Lane A Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
5
|
Iwata F, Shirasawa T, Mizutani Y, Ushiki T. Scanning ion-conductance microscopy with a double-barreled nanopipette for topographic imaging of charged chromosomes. Microscopy (Oxf) 2021; 70:423-435. [PMID: 33644794 DOI: 10.1093/jmicro/dfab009] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 02/12/2021] [Accepted: 02/26/2021] [Indexed: 11/13/2022] Open
Abstract
Scanning ion conductance microscopy (SICM) is useful for imaging soft and fragile biological samples in liquids because it probes the samples' surface topography by detecting ion currents under non-contact and force-free conditions. SICM acquires the surface topographical height by detecting the ion current reduction that occurs when an electrolyte-filled glass nanopipette approaches the sample surface. However, most biological materials have electrically charged surfaces in liquid environments, which sometimes affect the behavior of the ion currents detected by SICM and, especially, make topography measurements difficult. For measuring such charged samples, we propose a novel imaging method that uses a double-barrel nanopipette as an SICM probe. The ion current between the two apertures of the nanopipette desensitizes the surface charge effect on imaging. In this study, metaphase chromosomes of Indian muntjac were imaged by this technique because, owing to their strongly negatively charged surfaces in phosphate-buffered saline, it is difficult to obtain the topography of the chromosomes by the conventional SICM with a single-aperture nanopipette. Using the proposed method with a double-barrel nanopipette, the surfaces of the chromosomes were successfully measured, without any surface charge confounder. Since the detailed imaging of sample topography can be performed in physiological liquid conditions regardless of the sample charge, it is expected to be used for analyzing the high-order structure of chromosomes in relation to their dynamic changes in the cell division.
Collapse
Affiliation(s)
- Futoshi Iwata
- Graduate School of Integrated Science and Technology, Shizuoka University, Hamamatsu, Shizuoka 432-8561, Japan.,Research Institute of Electronics, Shizuoka University, Hamamatsu, Shizuoka 432-8011, Japan
| | - Tatsuru Shirasawa
- Graduate School of Integrated Science and Technology, Shizuoka University, Hamamatsu, Shizuoka 432-8561, Japan
| | - Yusuke Mizutani
- Office of Institutional Research, Hokkaido University, Sapporo, Hokkaido 060-0808, Japan.,Division of Microscopic Anatomy, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8510, Japan
| | - Tatsuo Ushiki
- Division of Microscopic Anatomy, Graduate School of Medical and Dental Sciences, Niigata University, Niigata 951-8510, Japan
| |
Collapse
|
6
|
Klenerman D, Korchev Y, Novak P, Shevchuk A. Noncontact Nanoscale Imaging of Cells. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2021; 14:347-361. [PMID: 34314223 DOI: 10.1146/annurev-anchem-091420-120101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The reduction in ion current as a fine pipette approaches a cell surface allows the cell surface topography to be imaged, with nanoscale resolution, without contact with the delicate cell surface. A variety of different methods have been developed and refined to scan the topography of the dynamic cell surface at high resolution and speed. Measurement of cell topography can be complemented by performing local probing or mapping of the cell surface using the same pipette. This can be done by performing single-channel recording, applying force, delivering agonists, using pipettes fabricated to contain an electrochemical probe, or combining with fluorescence imaging. These methods in combination have great potential to image and map the surface of live cells at the nanoscale.
Collapse
Affiliation(s)
- David Klenerman
- Department of Chemistry, University of Cambridge, Cambridge CB2 1EW, United Kingdom;
| | - Yuri Korchev
- Imperial College Faculty of Medicine, London Centre for Nanotechnology, London W12 0NN, United Kingdom
- Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan
| | - Pavel Novak
- Imperial College Faculty of Medicine, London Centre for Nanotechnology, London W12 0NN, United Kingdom
- National University of Science and Technology (MISiS), Moscow 119991, Russia
| | - Andrew Shevchuk
- Imperial College Faculty of Medicine, London Centre for Nanotechnology, London W12 0NN, United Kingdom
| |
Collapse
|
7
|
Scanning ion conductance microscopy of isolated metaphase chromosomes in a liquid environment. Chromosome Res 2021; 29:95-106. [PMID: 33694044 DOI: 10.1007/s10577-021-09659-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 02/28/2021] [Accepted: 03/04/2021] [Indexed: 10/21/2022]
Abstract
Scanning probe microscopy (SPM) uses a probing tip which scans over a sample surface for obtaining information on the sample surface characteristics. Among various types of SPM, atomic force microscopy (AFM) has been widely applied to imaging of biological samples including chromosomes. Scanning ion conductance microscopy (SICM) has been also introduced for visualizing the surface structure of biological samples because it can obtain "contact-free" topographic images in liquid conditions by detecting ion current flow through a pipette opening. However, we recently noticed that the consistent imaging of chromosomes is difficult by SICM. In this paper, the behaviors of the ion current on the sample surfaces were precisely investigated for obtaining SICM images of isolated muntjac metaphase chromosomes more consistently than at present. The present study revealed that application of positive potential to the pipette electrode was acceptable for obtaining the topographic image of chromosomes, while application of negative potential failed in imaging. The approach curves were then studied for analyzing the relationship between the ion current and the tip sample distance when the pipette is approaching chromosomes. The current-voltage (I-V) curve further provided us the accurate interpretation of the ion current behavior during chromosome imaging. These data were further compared with those for SICM imaging of HeLa cells. Our findings indicated that chromosomes are electrically charged and the net charge is strongly negative in normal Dulbecco's phosphate buffered saline. We finally showed that the ion concentration of the bath electrolyte is important for imaging chromosomes by SICM.
Collapse
|
8
|
Li P, Li G. Advances in Scanning Ion Conductance Microscopy: Principles and Applications. IEEE NANOTECHNOLOGY MAGAZINE 2021. [DOI: 10.1109/mnano.2020.3037431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
9
|
Zhuang J, Yan H, Zheng Q, Wang T, Liao X. Study on a Rapid Imaging Method for Scanning Ion Conductance Microscopy Using a Double-Barreled Theta Pipette. Anal Chem 2020; 92:15789-15798. [PMID: 33283496 DOI: 10.1021/acs.analchem.0c02840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Scanning ion conductance microscopy (SICM) is a new noncontact, high-resolution scanning probe microscopy technique, which has become increasingly popular in recent years. The hopping mode-currently the most widely used scanning mode-can be used for imaging samples with complicated surface topographies. However, its slow scanning rate seriously restricts its broader application. This paper proposes a fast imaging control mode using a double-barreled theta pipette as the probe, which effectively increases the imaging rate. In this mode, sample surface height information is obtained when the double-barreled theta pipette approaches the sample in a two-step downward process. The ion current sum of two barrels and ion current of one barrel are used as feedback signals to approach the sample until the feedback signals decrease to the set threshold, respectively, thereby obtaining the height of the imaging point. First, this work used COMSOL to establish an SICM model and perform simulation analysis. The simulation results verified the proposed method's feasibility. Second, a scanning time mathematical model was established. The results revealed that the new method is superior to the traditional method in terms of imaging rate. Finally, experiments were performed on poly(dimethylsiloxane) (PDMS) samples using the two imaging modes described above. The results demonstrated that the new scanning mode could significantly improve the imaging rate of SICM without a loss in imaging quality and stability.
Collapse
Affiliation(s)
- Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Heng Yan
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Qiangqiang Zheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Tingkai Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.,School of Manufacturing Science and Engineering, Key Laboratory of Testing Technology for Manufacturing Process, Ministry of Education, Southwest University of Science and Technology, Mianyang 621010, China
| |
Collapse
|
10
|
Zhuang J, Cheng L, Liao X, Zia AA, Wang Z. A fuzzy control for high-speed and low-overshoot hopping probe ion conductance microscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:033703. [PMID: 32259936 DOI: 10.1063/1.5114642] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 02/07/2020] [Indexed: 06/11/2023]
Abstract
At present, hopping probe ion conductance microscopy (HPICM) is the most capable ion conductance microscopy for imaging complex surface topography. However, the HPICM controller usually does not begin to stop the pipette sample approach until the ion current reaches a threshold, which results in short deceleration distances. Furthermore, closed-loop piezo actuation usually increases the response time. These problems tend to increase the ion current overshoot and affect imaging speed and quality. A fuzzy control system was developed to solve these problems via ion current deviation and deviation rate. This lengthens the deceleration distance to enable a high-speed approach toward the sample and smooth deceleration. Open-loop control of the piezo actuator is also used to increase sensitivity. To compensate for the nonlinearity of the actuator, a multi-section fuzzy logic strategy was used to maintain performance in all sections. Glass and poly(dimethylsiloxane) samples were used to demonstrate greater imaging speed and stability of the fuzzy controller relative to those of conventional controllers.
Collapse
Affiliation(s)
- Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Lei Cheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Ali Akmal Zia
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Zhiwu Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
11
|
Takahashi Y, Zhou Y, Miyamoto T, Higashi H, Nakamichi N, Takeda Y, Kato Y, Korchev Y, Fukuma T. High-Speed SICM for the Visualization of Nanoscale Dynamic Structural Changes in Hippocampal Neurons. Anal Chem 2019; 92:2159-2167. [PMID: 31840491 DOI: 10.1021/acs.analchem.9b04775] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Dynamic reassembly of the cytoskeleton and structural changes represented by dendritic spines, cargo transport, and synapse formation are closely related to memory. However, the visualization of the nanoscale topography is challenging because of the diffraction limit of optical microscopy. Scanning ion conductance microscopy (SICM) is an effective tool for visualizing the nanoscale topography changes of the cell surface without labeling. The temporal resolution of SICM is a critical issue of live-cell time-lapse imaging. Here, we developed a new scanning method, automation region of interest (AR)-mode SICM, to select the next imaging region by predicting the location of a cell, thus improving the scanning speed of time-lapse imaging. The newly developed algorithm reduced the scanning time by half. The time-lapse images provided not only novel information about nanoscale structural changes but also quantitative information on the dendritic spine and synaptic bouton volume changes and formation process of the neural network that are closely related to memory. Furthermore, translocation of plasmalemmal precursor vesicles (ppvs), for which fluorescent labeling has not been established, were also visualized along with the rearrangement of the cytoskeleton at the growth cone.
Collapse
Affiliation(s)
- Yasufumi Takahashi
- WPI Nano Life Science Institute (WPI-NanoLSI) , Kanazawa University , Kanazawa 920-1192 , Japan.,Precursory Research for Embryonic Science and Technology (PRESTO) , Japan Science and Technology Agency (JST) , Saitama 332-0012 , Japan
| | - Yuanshu Zhou
- WPI Nano Life Science Institute (WPI-NanoLSI) , Kanazawa University , Kanazawa 920-1192 , Japan
| | - Takafumi Miyamoto
- Department Division of Electrical Engineering and Computer Science , Kanazawa University , Kanazawa 920-1192 , Japan
| | - Hiroki Higashi
- Department Division of Electrical Engineering and Computer Science , Kanazawa University , Kanazawa 920-1192 , Japan
| | - Noritaka Nakamichi
- Faculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences , Kanazawa University , Kanazawa 920-1192 , Japan
| | - Yuka Takeda
- Faculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences , Kanazawa University , Kanazawa 920-1192 , Japan
| | - Yukio Kato
- Faculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences , Kanazawa University , Kanazawa 920-1192 , Japan
| | - Yuri Korchev
- WPI Nano Life Science Institute (WPI-NanoLSI) , Kanazawa University , Kanazawa 920-1192 , Japan.,Department of Medicine , Imperial College London , London W12 0NN , United Kingdom.,National University of Science and Technology (MISiS) , Leninskiy prospect 4 , Moscow 119049 , Russia
| | - Takeshi Fukuma
- WPI Nano Life Science Institute (WPI-NanoLSI) , Kanazawa University , Kanazawa 920-1192 , Japan
| |
Collapse
|
12
|
Simeonov S, Schäffer TE. Ultrafast Imaging of Cardiomyocyte Contractions by Combining Scanning Ion Conductance Microscopy with a Microelectrode Array. Anal Chem 2019; 91:9648-9655. [PMID: 31247725 DOI: 10.1021/acs.analchem.9b01092] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Beating cardiomyocytes undergo fast morphodynamics during the contraction-relaxation cycle. However, imaging these morphodynamics with a high spatial and temporal resolution is difficult, owing to a lack of suitable techniques. Here, we combine scanning ion conductance microscopy (SICM) with a microelectrode array (MEA) to image the three-dimensional (3D) topography of cardiomyocytes during a contraction-relaxation cycle with 1 μm spatial and 1 ms time resolution. We record the vertical motion of cardiomyocytes at many locations across a cell by SICM and synchronize these data using the simultaneously recorded action potential by the MEA as a time reference. This allows us to reconstruct the time-resolved 3D morphology of cardiomyocytes during a full contraction-relaxation cycle with a raw data rate of 200 μs/frame and to generate spatially resolved images of contractile parameters (maximum displacement, time delay, asymmetry factor). We use the MEA-SICM setup to visualize the effect of blebbistatin, a myosin II inhibitor, on the morphodynamics of contractions. Further, we find an upper limit of 0.02% for cell volume changes during an action potential. The results show that MEA-SICM provides an ultrafast imaging platform for investigating the functional interplay of cardiomyocyte electrophysiology and mechanics.
Collapse
Affiliation(s)
- Stefan Simeonov
- Institute of Applied Physics , University of Tübingen , Auf der Morgenstelle 10 , 72076 Tübingen , Germany
| | - Tilman E Schäffer
- Institute of Applied Physics , University of Tübingen , Auf der Morgenstelle 10 , 72076 Tübingen , Germany
| |
Collapse
|
13
|
Zhuang J, Wang Z, Liao X, Gao B, Cheng L. Hierarchical spiral-scan trajectory for efficient scanning ion conductance microscopy. Micron 2019; 123:102683. [PMID: 31129536 DOI: 10.1016/j.micron.2019.102683] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 05/15/2019] [Accepted: 05/16/2019] [Indexed: 10/26/2022]
Abstract
Scanning ion conductance microscopy (SICM) is an emerging technique for non-contact, high-resolution topography imaging, especially suitable for live cells investigation in a physiological environment. Despite its rapid development, the extended acquisition time issues of its typical hopping/backstep scanning mode still restrict its application for more fields. Herein, we propose a novel SICM scanning approach to effectively reduce the retract distance of existing hopping/backstep mode. In this approach, the SICM probe first gradually descends in the z-direction. Then by using Archimedes spiral trajectory, which has the advantage of higher angular velocity due to its continuous and smooth trajectory, the probe rapidly detects the highest point of the sample in the xy-plane in a layer-by-layer way. Further, the maximum height that decides the retrace distance of pipet in the detected region can be quickly achieved, avoiding a huge retrace distance usually adopted in the existing methods without any prior knowledge (sample height and steepness in the scanning region). Therefore, this new scanning method can greatly reduce the imaging time by minimizing the retrace height of each measurement point. Theoretical analysis is conducted to compare the imaging time of traditional and new method. And various factors in the new method that affect the imaging speed are analyzed. In addition, PDMS (polydimethylsiloxane) and biological samples (C2C12 cells) were imaged by SICM that was operated in the hopping mode, raster-based detecting and developed method with a single-barrel pipet, respectively. The experimental results suggest that the new method has a faster imaging speed than conventional scanning modes but does not sacrifice the imaging quality.
Collapse
Affiliation(s)
- Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.
| | - Zhiwu Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China; School of Manufacturing Science and Engineering, Southwest University of Science and Technology, Mianyang, 621010, China
| | - Bingli Gao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Lei Cheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an, 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| |
Collapse
|
14
|
Simeonov S, Schäffer TE. High-speed scanning ion conductance microscopy for sub-second topography imaging of live cells. NANOSCALE 2019; 11:8579-8587. [PMID: 30994121 DOI: 10.1039/c8nr10162k] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Scanning ion conductance microscopy (SICM) is an emerging tool for non-invasive and high-resolution topography imaging of live cells. However, the imaging speed of conventional SICM setups is slow, requiring several seconds or even minutes per image, thereby making it difficult to study cellular dynamics. Here, we describe a high-speed SICM (HS-SICM) setup for topography imaging in the hopping mode with a pixel rate of 11.0 kHz, which is 15 times faster than what was reported before. In combination with a "turn step" procedure for rapid pipette retraction, we image the ultra-fast morphodynamics of live human platelets, A6 cells, and U2OS cells at a rate as fast as 0.6 s per frame. The results show that HS-SICM provides a useful platform for investigating the dynamics of cell morphology on a sub-second timescale.
Collapse
Affiliation(s)
- Stefan Simeonov
- Institute of Applied Physics, University of Tübingen, Auf der Morgenstelle 10, 72076 Tübingen, Germany.
| | | |
Collapse
|
15
|
Rheinlaender J, Schäffer TE. Mapping the creep compliance of living cells with scanning ion conductance microscopy reveals a subcellular correlation between stiffness and fluidity. NANOSCALE 2019; 11:6982-6989. [PMID: 30916074 DOI: 10.1039/c8nr09428d] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Living cells exhibit complex material properties, which play a crucial role in many aspects of cell function in health and disease, including migration, proliferation, differentiation, and apoptosis. Various techniques exist to probe the viscoelastic material properties of living cells and a frequent observation is a cell-to-cell correlation between average stiffness and fluidity in populations of cells. However, the origin of this correlation is still under discussion. Here, we introduce an imaging technique based on the scanning ion conductance microscope (SICM) to measure the creep compliance of soft samples, which allowed us to generate images of viscoelastic material properties of living cells with high spatial and temporal resolution. We observe a strong subcellular correlation between the local stiffness and fluidity across the individual living cell: stiff regions exhibit lower fluidity while soft regions exhibit higher fluidity. We find that this subcellular correlation is identical to the previously observed cell-to-cell correlation. The subcellular correlation reversibly vanishes after drug-induced disruption of the cytoskeleton, indicating that the subcellular correlation is a property of the intact cytoskeleton of the living cell.
Collapse
Affiliation(s)
- Johannes Rheinlaender
- Institute of Applied Physics, University of Tübingen, Auf der Morgenstelle 10, 72076 Tübingen, Germany.
| | | |
Collapse
|
16
|
Wang Z, Zhuang J, Gao Z, Liao X. A fast scanning ion conductance microscopy imaging method using compressive sensing and low-discrepancy sequences. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:113709. [PMID: 30501305 DOI: 10.1063/1.5048656] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Accepted: 11/02/2018] [Indexed: 06/09/2023]
Abstract
A scanning ion conductance microscope (SICM) is a multifunctional, high-resolution imaging technique whose non-contact nature makes it very suitable for imaging of biological samples such as living cells in a physiological environment. However, a drawback of hopping/backstep mode of SICM is its relatively slow imaging speed, which seriously restricts the study on the dynamic process of biological samples. This paper presents a new undersampled scanning method based on Compressed Sensing (CS-based scanning mode) theory to solve extended acquisition time issues in the hopping/backstep mode. Compressive sensing can break through the limit of the Nyquist sampling theorem and sample the original sparse/compressible signal at a rate lower than the Nyquist frequency. In the CS-based scanning mode, three sampling patterns, including the random sampling pattern and two kinds of sampling patterns produced by low-discrepancy sequences, were employed as the measurement locations to obtain the undersampled data with different undersampling ratios. Also TVAL3 (Total Variation Augmented Lagrangian ALternating-direction ALgorithm) was then utilized as a reconstruction algorithm to reconstruct the undersampled data. Compared with the nonuniform sampling points of random patterns at a low undersampling ratio, low-discrepancy sequences can produce a more uniform distribution point. Three types of samples with different complexity of topography were scanned by SICM using the conventional hopping/backstep mode and CS-based undersampled scanning mode. The comparisons of the imaging speed and quality with two scanning modes illustrate that the CS-based scanning mode can effectively speed up SICM imaging speed while not sacrificing the image quality. Also low-discrepancy sampling patterns can achieve a better reconstruction performance than that of the random sampling pattern under the same undersampling ratio.
Collapse
Affiliation(s)
- Zhiwu Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Zijun Gao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
17
|
A continuous control mode with improved imaging rate for scanning ion conductance microscope (SICM). Ultramicroscopy 2018; 190:66-76. [DOI: 10.1016/j.ultramic.2018.04.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Revised: 03/29/2018] [Accepted: 04/16/2018] [Indexed: 11/19/2022]
|
18
|
Hagemann P, Gesper A, Happel P. Correlative Stimulated Emission Depletion and Scanning Ion Conductance Microscopy. ACS NANO 2018; 12:5807-5815. [PMID: 29791140 DOI: 10.1021/acsnano.8b01731] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Correlation microscopy combining fluorescence and scanning probe or electron microscopy is limited to fixed samples due to the sample preparation and nonphysiological imaging conditions required by most probe or electron microscopy techniques. Among the few scanning probe techniques that allow imaging of living cells under physiological conditions, scanning ion conductance microscopy (SICM) has been shown to be the technique that minimizes the impact on the investigated sample. However, combinations of SICM and fluorescence microscopy suffered from the mismatch in resolution due to the limited resolution of conventional light microscopy. In the last years, the diffraction limit of light microscopy has been circumvented by various techniques, one of which is stimulated emission depletion (STED) microscopy. Here, we aimed at demonstrating the combination of STED and SICM. We show that both methods allow recording a living cellular specimen and provide a SICM and STED image of the same sample, which allowed us to correlate the membrane surface topography and the distribution of the cytoskeletal protein actin. Our proof-of-concept study exemplifies the benefit of correlating SICM with a subdiffraction fluorescence method and might form the basis for the development of a combined instrument that would allow the simultaneous recording of subdiffraction fluorescence and topography information.
Collapse
Affiliation(s)
- Philipp Hagemann
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| | - Astrid Gesper
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| | - Patrick Happel
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| |
Collapse
|
19
|
Schierbaum N, Hack M, Betz O, Schäffer TE. Macro-SICM: A Scanning Ion Conductance Microscope for Large-Range Imaging. Anal Chem 2018; 90:5048-5054. [PMID: 29569436 DOI: 10.1021/acs.analchem.7b04764] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The scanning ion conductance microscope (SICM) is a versatile, high-resolution imaging technique that uses an electrolyte-filled nanopipet as a probe. Its noncontact imaging principle makes the SICM uniquely suited for the investigation of soft and delicate surface structures in a liquid environment. The SICM has found an ever-increasing number of applications in chemistry, physics, and biology. However, a drawback of conventional SICMs is their relatively small scan range (typically 100 μm × 100 μm in the lateral and 10 μm in the vertical direction). We have developed a Macro-SICM with an exceedingly large scan range of 25 mm × 25 mm in the lateral and 0.25 mm in the vertical direction. We demonstrate the high versatility of the Macro-SICM by imaging at different length scales: from centimeters (fingerprint, coin) to millimeters (bovine tongue tissue, insect wing) to micrometers (cellular extensions). We applied the Macro-SICM to the study of collective cell migration in epithelial wound healing.
Collapse
|
20
|
Rheinlaender J, Schäffer TE. An Accurate Model for the Ion Current–Distance Behavior in Scanning Ion Conductance Microscopy Allows for Calibration of Pipet Tip Geometry and Tip–Sample Distance. Anal Chem 2017; 89:11875-11880. [DOI: 10.1021/acs.analchem.7b03871] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Johannes Rheinlaender
- Institute of Applied Physics, University of Tübingen, Auf der Morgenstelle 10, 72076 Tübingen, Germany
| | - Tilman E. Schäffer
- Institute of Applied Physics, University of Tübingen, Auf der Morgenstelle 10, 72076 Tübingen, Germany
| |
Collapse
|
21
|
Scanning ion conductance microscopy for visualizing the three-dimensional surface topography of cells and tissues. Semin Cell Dev Biol 2017; 73:125-131. [PMID: 28939037 DOI: 10.1016/j.semcdb.2017.09.024] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 09/17/2017] [Accepted: 09/18/2017] [Indexed: 02/01/2023]
Abstract
Scanning ion conductance microscopy (SICM), which belongs to the family of scanning probe microscopy, regulates the tip-sample distance by monitoring the ion current through the use of an electrolyte-filled nanopipette as the probing tip. Thus, SICM enables "contact-free" imaging of cell surface topography in liquid conditions. In this paper, we applied hopping mode SICM for obtaining topographical images of convoluted tissue samples such as trachea and kidney in phosphate buffered saline. Some of the SICM images were compared with the images obtained by scanning electron microscopy (SEM) after drying the same samples. We showed that the imaging quality of hopping mode SICM was excellent enough for investigating the three-dimensional surface structure of the soft tissue samples. Thus, SICM is expected to be used for imaging a wide variety of cells and tissues - either fixed or alive- at high resolution under physiologically relevant liquid conditions.
Collapse
|
22
|
Gesper A, Hagemann P, Happel P. A low-cost, large field-of-view scanning ion conductance microscope for studying nanoparticle-cell membrane interactions. NANOSCALE 2017; 9:14172-14183. [PMID: 28905955 DOI: 10.1039/c7nr04306f] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Nanoparticles have the potential to become versatile tools in the medical and life sciences. One potential application is delivering drugs or other compounds to the cell cytoplasm, which requires the nanoparticles to bind to or cross the cell membrane. However, there are only a few tools available which allow studying the interaction of nanoparticles and the cell membrane of living cells in a physiological environment. Currently, the tool which least biases living cells is Scanning Ion Conductance Microscopy (SICM). Specialized SICMs allow imaging at high resolution, however, they are cost intensive, particularly when providing a large field-of-view. In contrast, less cost intensive SICMs which provide a large field-of-view do not allow imaging at high resolutions. We have developed a SICM setup consisting of a compact three-axis piezo system and an additional fast shear-force piezo actor. This combination allows imaging fields-of-view of up to 80 μm × 80 μm, recording sections of living cells with a temporal resolution in the range of minutes as well as imaging with a spatial resolution of below 70 nm. Using our SICM we found that the cell membrane of HeLa cells treated with carboxylated latex nanoparticles was significantly more convoluted compared to control cells. The SICM setup we introduce here combines high resolution imaging with a large field-of-view at low costs. Our setup only requires a mounting adapter to extend existing inverted light microscopes, thus it could be a valuable and cost effective tool for researchers in all fields of the medical and life sciences performing investigations at the nanometer scale.
Collapse
Affiliation(s)
- Astrid Gesper
- Nanoscopy Group, Central Unit for Ion beams and Radionuclides (RUBION), Ruhr-University Bochum, Universitätsstraβe 150, D-44780 Bochum, Germany.
| | | | | |
Collapse
|
23
|
Zhuang J, Jiao Y, Mugabo V. A new scanning mode to improve scanning ion conductance microscopy imaging rate with pipette predicted movement. Micron 2017; 101:177-185. [PMID: 28763735 DOI: 10.1016/j.micron.2017.07.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 07/15/2017] [Accepted: 07/15/2017] [Indexed: 11/29/2022]
Abstract
Scanning ion conductance microscopy (SICM) is a non-contact surface topography measurement technique that has been increasingly used for soft surfaces such as living biological samples. An approach-retract scanning (ARS) mode is widely used to avoid collision between the SICM probe (i.e., pipette) and an abrupt increase in sample profile. However, the redundant pipette trajectory in the ARS mode lengthens the scan time, thus reducing SICM efficiency and time resolution. To avoid this problem, a new scanning mode is discussed that adds horizontal movement at each measurement point to predict the upcoming sample topography via variation in ion current. The pipette then retracts in response to raised topography, while it raster scans flat or downhill topography. The feasibility was verified by finite element analysis and experimental tests on three kinds of soft samples: polydimethylsiloxane, mice cardiac fibroblasts, and breast cancer cells. The pixel detection frequency during imaging and the mean square error of the sample topography were compared for the two modes. The new scanning mode enhances the SICM imaging rate without loss of imaging quality or scanning stability, while it increases efficiency and time resolution. It thus has an improved performance for characterizing biological samples.
Collapse
Affiliation(s)
- Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
| | - Yangbohan Jiao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Vincent Mugabo
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China; School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
24
|
Seifert J, Rheinlaender J, Lang F, Gawaz M, Schäffer TE. Thrombin-induced cytoskeleton dynamics in spread human platelets observed with fast scanning ion conductance microscopy. Sci Rep 2017; 7:4810. [PMID: 28684746 PMCID: PMC5500533 DOI: 10.1038/s41598-017-04999-6] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Accepted: 05/19/2017] [Indexed: 02/08/2023] Open
Abstract
Platelets are small anucleate blood cells involved in haemostasis. Platelet activation, caused by agonists such as thrombin or by contact with the extracellular matrix, leads to platelet adhesion, aggregation, and coagulation. Activated platelets undergo shape changes, adhere, and spread at the site of injury to form a blood clot. We investigated the morphology and morphological dynamics of human platelets after complete spreading using fast scanning ion conductance microscopy (SICM). In contrast to unstimulated platelets, thrombin-stimulated platelets showed increased morphological activity after spreading and exhibited dynamic morphological changes in the form of wave-like movements of the lamellipodium and dynamic protrusions on the platelet body. The increase in morphological activity was dependent on thrombin concentration. No increase in activity was observed following exposure to other activation agonists or during contact-induced activation. Inhibition of actin polymerization and inhibition of dynein significantly decreased the activity of thrombin-stimulated platelets. Our data suggest that these morphological dynamics after spreading are thrombin-specific and might play a role in coagulation and blood clot formation.
Collapse
Affiliation(s)
- Jan Seifert
- Institute of Applied Physics, University of Tübingen, Tübingen, Germany
| | | | - Florian Lang
- Department of Physiology, University of Tübingen, Tübingen, Germany
| | - Meinrad Gawaz
- Department of Cardiology and Cardiovascular Diseases, University of Tübingen, Tübingen, Germany
| | - Tilman E Schäffer
- Institute of Applied Physics, University of Tübingen, Tübingen, Germany.
| |
Collapse
|
25
|
Zhuang J, Li Z, Jiao Y. Double micropipettes configuration method of scanning ion conductance microscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:073703. [PMID: 27475561 DOI: 10.1063/1.4958643] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In this paper, a new double micropipettes configuration mode of scanning ion conductance microscopy (SICM) is presented to better overcome ionic current drift and further improve the performance of SICM, which is based on a balance bridge circuit. The article verifies the feasibility of this new configuration mode from theoretical and experimental analyses, respectively, and compares the quality of scanning images in the conventional single micropipette configuration mode and the new double micropipettes configuration mode. The experimental results show that the double micropipettes configuration mode of SICM has better effect on restraining ionic current drift and better performance of imaging. Therefore, this article not only proposes a new direction of overcoming the ionic current drift but also develops a new method of SICM stable imaging.
Collapse
Affiliation(s)
- Jian Zhuang
- School of Mechanical Engineering, Xi'an Jiao Tong University, Xi'an 710049, People's Republic of China
| | - Zeqing Li
- School of Mechanical Engineering, Xi'an Jiao Tong University, Xi'an 710049, People's Republic of China
| | - Yangbohan Jiao
- School of Mechanical Engineering, Xi'an Jiao Tong University, Xi'an 710049, People's Republic of China
| |
Collapse
|
26
|
Kraus MJ, Seifert J, Strasser EF, Gawaz M, Schäffer TE, Rheinlaender J. Comparative morphology analysis of live blood platelets using scanning ion conductance and robotic dark-field microscopy. Platelets 2016; 27:541-6. [PMID: 27063564 DOI: 10.3109/09537104.2016.1158400] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Many conventional microscopy techniques for investigating platelet morphology such as electron or fluorescence microscopy require highly invasive treatment of the platelets such as fixation, drying and metal coating or staining. Here, we present two unique but entirely different microscopy techniques for direct morphology analysis of live, unstained platelets: scanning ion conductance microscopy (SICM) and robotic dark-field microscopy (RDM). We demonstrate that both techniques allow for a quantitative evaluation of the morphological features of live adherent platelets. We show that their morphology can be quantified by both techniques using the same geometric parameters and therefore can be directly compared. By imaging the same identical platelets subsequently with SICM and RDM, we found that area, perimeter and circularity of the platelets are directly correlated between SICM and dark-field microscopy (DM), while the fractal dimension (FD) differed between the two microscopy techniques. We show that SICM and RDM are both valuable tools for the ex vivo investigation of the morphology of live platelets, which might contribute to new insights into the physiological and pathophysiological role of platelet spreading.
Collapse
Affiliation(s)
- Max-Joseph Kraus
- a Geiselgasteig Ambulance , Grünwald , Munich , Germany.,b Institute for Medical Engineering and Information Processing , University of Koblenz , Koblenz , Germany
| | - Jan Seifert
- c Institute of Applied Physics , University of Tübingen , Tübingen , Germany
| | - Erwin F Strasser
- d University Hospital of Erlangen , Transfusion and Haemostaseology Department , Erlangen , Germany
| | - Meinrad Gawaz
- e Department of Cardiology and Cardiovascular Diseases , University of Tübingen , Tübingen , Germany
| | - Tilman E Schäffer
- c Institute of Applied Physics , University of Tübingen , Tübingen , Germany
| | | |
Collapse
|
27
|
Ossola D, Dorwling-Carter L, Dermutz H, Behr P, Vörös J, Zambelli T. Simultaneous Scanning Ion Conductance Microscopy and Atomic Force Microscopy with Microchanneled Cantilevers. PHYSICAL REVIEW LETTERS 2015; 115:238103. [PMID: 26684144 DOI: 10.1103/physrevlett.115.238103] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2015] [Indexed: 06/05/2023]
Abstract
We combined scanning ion conductance microscopy (SICM) and atomic force microscopy (AFM) into a single tool using AFM cantilevers with an embedded microchannel flowing into the nanosized aperture at the apex of the hollow pyramid. An electrode was positioned in the AFM fluidic circuit connected to a second electrode in the bath. We could thus simultaneously measure the ionic current and the cantilever bending (in optical beam deflection mode). First, we quantitatively compared the SICM and AFM contact points on the approach curves. Second, we estimated where the probe in SICM mode touches the sample during scanning on a calibration grid and applied the finding to image a network of neurites on a Petri dish. Finally, we assessed the feasibility of a double controller using both the ionic current and the deflection as input signals of the piezofeedback. The experimental data were rationalized in the framework of finite elements simulations.
Collapse
Affiliation(s)
- Dario Ossola
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Livie Dorwling-Carter
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Harald Dermutz
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Pascal Behr
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - János Vörös
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| | - Tomaso Zambelli
- Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
| |
Collapse
|
28
|
Jung GE, Noh H, Shin YK, Kahng SJ, Baik KY, Kim HB, Cho NJ, Cho SJ. Closed-loop ARS mode for scanning ion conductance microscopy with improved speed and stability for live cell imaging applications. NANOSCALE 2015; 7:10989-97. [PMID: 25959131 DOI: 10.1039/c5nr01577d] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Scanning ion conductance microscopy (SICM) is an increasingly useful nanotechnology tool for non-contact, high resolution imaging of live biological specimens such as cellular membranes. In particular, approach-retract-scanning (ARS) mode enables fast probing of delicate biological structures by rapid and repeated approach/retraction of a nano-pipette tip. For optimal performance, accurate control of the tip position is a critical issue. Herein, we present a novel closed-loop control strategy for the ARS mode that achieves higher operating speeds with increased stability. The algorithm differs from that of most conventional (i.e., constant velocity) approach schemes as it includes a deceleration phase near the sample surface, which is intended to minimize the possibility of contact with the surface. Analysis of the ion current and tip position demonstrates that the new mode is able to operate at approach speeds of up to 250 μm s(-1). As a result of the improved stability, SICM imaging with the new approach scheme enables significantly improved, high resolution imaging of subtle features of fixed and live cells (e.g., filamentous structures & membrane edges). Taken together, the results suggest that optimization of the tip approach speed can substantially improve SICM imaging performance, further enabling SICM to become widely adopted as a general and versatile research tool for biological studies at the nanoscale level.
Collapse
Affiliation(s)
- Goo-Eun Jung
- Research and Development Center, Park Systems, Suwon 443-270, Korea.
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Rheinlaender J, Schäffer TE. Lateral Resolution and Image Formation in Scanning Ion Conductance Microscopy. Anal Chem 2015; 87:7117-24. [DOI: 10.1021/acs.analchem.5b00900] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- Johannes Rheinlaender
- Institute of Applied Physics, University of Tübingen, Auf
der Morgenstelle 10, 72076 Tübingen, Germany
| | - Tilman E. Schäffer
- Institute of Applied Physics, University of Tübingen, Auf
der Morgenstelle 10, 72076 Tübingen, Germany
| |
Collapse
|
30
|
Seifert J, Rheinlaender J, Novak P, Korchev YE, Schäffer TE. Comparison of Atomic Force Microscopy and Scanning Ion Conductance Microscopy for Live Cell Imaging. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2015; 31:6807-13. [PMID: 26011471 DOI: 10.1021/acs.langmuir.5b01124] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Atomic force microscopy (AFM) and scanning ion conductance microscopy (SICM) are excellent and commonly used techniques for imaging the topography of living cells with high resolution. We present a direct comparison of AFM and SICM for imaging microvilli, which are small features on the surface of living cells, and for imaging the shape of whole cells. The imaging quality on microvilli increased significantly after cell fixation for AFM, whereas for SICM it remained constant. The apparent shape of whole cells in the case of AFM depended on the imaging force, which deformed the cell. In the case of SICM, cell deformations were avoided, owing to the contact-free imaging mechanism. We estimated that the lateral resolution on living cells is limited by the cell's elastic modulus for AFM, while it is not for SICM. By long-term, time-lapse imaging of microvilli dynamics, we showed that the imaging quality decreased with time for AFM, while it remained constant for SICM.
Collapse
Affiliation(s)
- Jan Seifert
- †Institute of Applied Physics, University of Tübingen, Tübingen, Germany
| | | | - Pavel Novak
- ‡Division of Medicine, Imperial College London, London, U.K
- §School of Engineering and Materials Science, Queen Mary University of London, London, U.K
| | - Yuri E Korchev
- ‡Division of Medicine, Imperial College London, London, U.K
| | - Tilman E Schäffer
- †Institute of Applied Physics, University of Tübingen, Tübingen, Germany
| |
Collapse
|
31
|
Gesper A, Thatenhorst D, Wiese S, Tsai T, Dietzel ID, Happel P. Long-term, long-distance recording of a living migrating neuron by scanning ion conductance microscopy. SCANNING 2015; 37:226-231. [PMID: 25728639 DOI: 10.1002/sca.21200] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2014] [Accepted: 02/06/2015] [Indexed: 06/04/2023]
Abstract
Bias-free, three-dimensional imaging of entire living cellular specimen is required for investigating shape and volume changes that occur during cellular growth or migration. Here we present fifty consecutive recordings of a living cultured neuron from a mouse dorsal root ganglion obtained by Scanning ion conductance microscopy (SICM). We observed a saltatory migration of the neuron with a mean velocity of approximately 20 μm/h. These results demonstrate the non-invasiveness of SICM, which makes it unique among the scanning probe microscopes. In contrast to SICM, most scanning probe techniques require a usually denaturating preparation of the cells, or they exert a non-negligible force on the cellular membrane, impeding passive observation. Moreover, the present series of recordings demonstrates the potential use of SICM for the detailed investigation of cellular migration and membrane surface dynamics even of such delicate samples as living neurons.
Collapse
Affiliation(s)
- Astrid Gesper
- Department of Biochemisty II, Electrobiochemistry of Neural Cells, Ruhr University Bochum, Bochum, Germany
- Central Unit for Ionbeams and Radionuclides (RUBION), Ruhr University Bochum, Bochum, Germany
| | - Denis Thatenhorst
- Department of Biochemisty II, Electrobiochemistry of Neural Cells, Ruhr University Bochum, Bochum, Germany
- International Graduate School of Neuroscience (IGSN), Ruhr University Bochum, Bochum, Germany
| | - Stefan Wiese
- Department of Cell Morphology and Molecular Neurobiology, Molecular Cell Biology, Ruhr-University Bochum, Bochum, Germany
| | - Teresa Tsai
- Department of Cell Morphology and Molecular Neurobiology, Molecular Cell Biology, Ruhr-University Bochum, Bochum, Germany
| | - Irmgard D Dietzel
- Department of Biochemisty II, Electrobiochemistry of Neural Cells, Ruhr University Bochum, Bochum, Germany
| | - Patrick Happel
- Central Unit for Ionbeams and Radionuclides (RUBION), Ruhr University Bochum, Bochum, Germany
| |
Collapse
|
32
|
Scheenen WJJM, Celikel T. Nanophysiology: Bridging synapse ultrastructure, biology, and physiology using scanning ion conductance microscopy. Synapse 2015; 69:233-41. [PMID: 25655013 DOI: 10.1002/syn.21807] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Accepted: 01/22/2015] [Indexed: 01/01/2023]
Abstract
Synaptic communication is at the core of neural circuit function, and its plasticity allows the nervous system to adapt to the changes in its environment. Understanding the mechanisms of this synaptic (re)organization will benefit from novel methodologies that enable simultaneous study of synaptic ultrastructure, biology, and physiology in identified circuits. Here, we describe one of these methodologies, i.e., scanning ion conductance microscopy (SICM), for electrical mapping of the membrane anatomy in tens of nanometers resolution in living neurons. When combined with traditional patch-clamp and fluorescence microscopy techniques, and the newly emerging nanointerference methodologies, SICM has the potential to mechanistically bridge the synaptic structure and function longitudinally throughout the life of a synapse.
Collapse
Affiliation(s)
- Wim J J M Scheenen
- Department of Neurophysiology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen, The Netherlands
| | | |
Collapse
|
33
|
Kim J, Kim SO, Cho NJ. Alternative configuration scheme for signal amplification with scanning ion conductance microscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:023706. [PMID: 25725851 DOI: 10.1063/1.4907360] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Scanning Ion Conductance Microscopy (SICM) is an emerging nanotechnology tool to investigate the morphology and charge transport properties of nanomaterials, including soft matter. SICM uses an electrolyte filled nanopipette as a scanning probe and detects current changes based on the distance between the nanopipette apex and the target sample in an electrolyte solution. In conventional SICM, the pipette sensor is excited by applying voltage as it raster scans near the surface. There have been attempts to improve upon raster scanning because it can induce collisions between the pipette sidewalls and target sample, especially for soft, dynamic materials (e.g., biological cells). Recently, Novak et al. demonstrated that hopping probe ion conductance microscopy (HPICM) with an adaptive scan method can improve the image quality obtained by SICM for such materials. However, HPICM is inherently slower than conventional raster scanning. In order to optimize both image quality and scanning speed, we report the development of an alternative configuration scheme for SICM signal amplification that is based on applying current to the nanopipette. This scheme overcomes traditional challenges associated with low bandwidth requirements of conventional SICM. Using our alternative scheme, we demonstrate successful imaging of L929 fibroblast cells and discuss the capabilities of this instrument configuration for future applications.
Collapse
Affiliation(s)
- Joonhui Kim
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| | - Seong-Oh Kim
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| | - Nam-Joon Cho
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| |
Collapse
|
34
|
Thatenhorst D, Rheinlaender J, Schäffer TE, Dietzel ID, Happel P. Effect of Sample Slope on Image Formation in Scanning Ion Conductance Microscopy. Anal Chem 2014; 86:9838-45. [DOI: 10.1021/ac5024414] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Denis Thatenhorst
- Department
of Biochemistry II, Electrobiochemistry of Neural Cells, Ruhr-University Bochum, Universitätsstraße 150, 44780 Bochum, Germany
- International
Graduate School of Neuroscience (IGSN), Ruhr-University Bochum, Universitätsstraße 150, 44780 Bochum, Germany
| | - Johannes Rheinlaender
- Institute
of Applied Physics and LISA+, University of Tübingen, Auf
der Morgenstelle 10, 72076 Tübingen, Germany
| | - Tilman E. Schäffer
- Institute
of Applied Physics and LISA+, University of Tübingen, Auf
der Morgenstelle 10, 72076 Tübingen, Germany
| | - Irmgard D. Dietzel
- Department
of Biochemistry II, Electrobiochemistry of Neural Cells, Ruhr-University Bochum, Universitätsstraße 150, 44780 Bochum, Germany
| | - Patrick Happel
- Central
Unit for Ionbeams and Radionuclides (RUBION), Ruhr-University Bochum, Universitätsstraße 150, 44780 Bochum, Germany
| |
Collapse
|
35
|
McKelvey K, Perry D, Byers JC, Colburn AW, Unwin PR. Bias Modulated Scanning Ion Conductance Microscopy. Anal Chem 2014; 86:3639-46. [DOI: 10.1021/ac5003118] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Kim McKelvey
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Joshua C. Byers
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Alex W. Colburn
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry and ‡MOAC Doctoral Training Centre, University of Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
36
|
Happel P, Möller K, Schwering NK, Dietzel ID. Migrating oligodendrocyte progenitor cells swell prior to soma dislocation. Sci Rep 2013; 3:1806. [PMID: 23657670 PMCID: PMC3648797 DOI: 10.1038/srep01806] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Accepted: 04/24/2013] [Indexed: 11/09/2022] Open
Abstract
The migration of oligodendrocyte progenitor cells (OPCs) to the white matter is an indispensable requirement for an intact brain function. The mechanism of cell migration in general is not yet completely understood. Nevertheless, evidence is accumulating that besides the coordinated rearrangement of the cytoskeleton, a finetuned interplay of ion and water fluxes across the cell membrane is essential for cell migration. One part of a general hypothesis is that a local volume increase towards the direction of movement triggers a mechano-activated calcium influx that regulates various procedures at the rear end of a migrating cell. Here, we investigated cell volume changes of migrating OPCs using scanning ion conductance microscopy. We found that during accelerated migration OPCs undergo an increase in the frontal cell body volume. These findings are supplemented with time lapse calcium imaging data that hint an increase in calcium content the frontal part of the cell soma.
Collapse
Affiliation(s)
- Patrick Happel
- Central Unit for Ionbeams and Radionuclides (RUBION), Ruhr-University Bochum, Bochum, Germany.
| | | | | | | |
Collapse
|
37
|
Scanning ion conductance microscopy for imaging biological samples in liquid: A comparative study with atomic force microscopy and scanning electron microscopy. Micron 2012; 43:1390-8. [DOI: 10.1016/j.micron.2012.01.012] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2011] [Revised: 01/25/2012] [Accepted: 01/25/2012] [Indexed: 11/18/2022]
|
38
|
Abstract
Scanning ion conductance microscopy (SICM) is a scanning probe technique that utilizes the increase in access resistance that occurs if an electrolyte filled glass micro-pipette is approached towards a poorly conducting surface. Since an increase in resistance can be monitored before the physical contact between scanning probe tip and sample, this technique is particularly useful to investigate the topography of delicate samples such as living cells. SICM has shown its potential in various applications such as high resolution and long-time imaging of living cells or the determination of local changes in cellular volume. Furthermore, SICM has been combined with various techniques such as fluorescence microscopy or patch clamping to reveal localized information about proteins or protein functions. This review details the various advantages and pitfalls of SICM and provides an overview of the recent developments and applications of SICM in biological imaging. Furthermore, we show that in principle, a combination of SICM and ion selective micro-electrodes enables one to monitor the local ion activity surrounding a living cell.
Collapse
|
39
|
A hybrid scanning mode for fast scanning ion conductance microscopy (SICM) imaging. Ultramicroscopy 2012; 121:1-7. [PMID: 22902298 PMCID: PMC3462995 DOI: 10.1016/j.ultramic.2012.06.015] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2012] [Revised: 05/28/2012] [Accepted: 06/26/2012] [Indexed: 11/25/2022]
Abstract
We have developed a new method of controlling the pipette for scanning ion conductance microscopy to obtain high-resolution images faster. The method keeps the pipette close to the surface during a single line scan but does not follow the exact surface topography, which is calculated by using the ion current. Using an FPGA platform we demonstrate this new method on model test samples and then on live cells. This method will be particularly useful to follow changes occurring on relatively flat regions of the cell surface at high spatial and temporal resolutions.
Collapse
|
40
|
Measuring the elastic properties of living cells through the analysis of current-displacement curves in scanning ion conductance microscopy. Pflugers Arch 2012; 464:307-16. [PMID: 22744227 DOI: 10.1007/s00424-012-1127-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2012] [Revised: 06/05/2012] [Accepted: 06/07/2012] [Indexed: 12/21/2022]
Abstract
Knowledge of mechanical properties of living cells is essential to understand their physiological and pathological conditions. To measure local cellular elasticity, scanning probe techniques have been increasingly employed. In particular, non-contact scanning ion conductance microscopy (SICM) has been used for this purpose; thanks to the application of a hydrostatic pressure via the SICM pipette. However, the measurement of sample deformations induced by weak pressures at a short distance has not yet been carried out. A direct quantification of the applied pressure has not been also achieved up to now. These two issues are highly relevant, especially when one addresses the investigation of thin cell regions. In this paper, we present an approach to solve these problems based on the use of a setup integrating SICM, atomic force microscopy, and optical microscopy. In particular, we describe how we can directly image the pipette aperture in situ. Additionally, we can measure the force induced by a constant hydrostatic pressure applied via the pipette over the entire probe-sample distance range from a remote point to contact. Then, we demonstrate that the sample deformation induced by an external pressure applied to the pipette can be indirectly and reliably evaluated from the analysis of the current-displacement curves. This method allows us to measure the linear relationship between indentation and applied pressure on uniformly deformable elastomers of known Young's modulus. Finally, we apply the method to murine fibroblasts and we show that it is sensitive to local and temporally induced variations of the cell surface elasticity.
Collapse
|
41
|
Yang X, Liu X, Lu H, Zhang X, Ma L, Gao R, Zhang Y. Real-Time Investigation of Acute Toxicity of ZnO Nanoparticles on Human Lung Epithelia with Hopping Probe Ion Conductance Microscopy. Chem Res Toxicol 2012; 25:297-304. [PMID: 22191635 DOI: 10.1021/tx2004823] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Xi Yang
- Nanomedicine Laboratory, China National Academy of Nanotechnology & Engineering, Tianjin, China 300457
- Department of Neurosurgery, Tianjin Medical University General Hospital; Tianjin Neurological Institute; Key Laboratory of Post-trauma
Neuro-repair and Regeneration in Central Nervous System, Ministry of Education; Tianjin Key Laboratory of Injuries, Variations and Regeneration of Nervous System, Tianjin, People's Republic of China 300052
| | - Xiao Liu
- Nanomedicine Laboratory, China National Academy of Nanotechnology & Engineering, Tianjin, China 300457
| | - Hujie Lu
- Nanomedicine Laboratory, China National Academy of Nanotechnology & Engineering, Tianjin, China 300457
| | - Xiaofan Zhang
- Nanomedicine Laboratory, China National Academy of Nanotechnology & Engineering, Tianjin, China 300457
| | - Liying Ma
- Nanomedicine Laboratory, China National Academy of Nanotechnology & Engineering, Tianjin, China 300457
| | - Ruiling Gao
- Nanomedicine Laboratory, China National Academy of Nanotechnology & Engineering, Tianjin, China 300457
| | - Yanjun Zhang
- Nanomedicine Laboratory, China National Academy of Nanotechnology & Engineering, Tianjin, China 300457
- Department of Neurosurgery, Tianjin Medical University General Hospital; Tianjin Neurological Institute; Key Laboratory of Post-trauma
Neuro-repair and Regeneration in Central Nervous System, Ministry of Education; Tianjin Key Laboratory of Injuries, Variations and Regeneration of Nervous System, Tianjin, People's Republic of China 300052
| |
Collapse
|
42
|
|
43
|
Yang X, Liu X, Zhang X, Lu H, Zhang J, Zhang Y. Investigation of morphological and functional changes during neuronal differentiation of PC12 cells by combined Hopping Probe Ion Conductance Microscopy and patch-clamp technique. Ultramicroscopy 2011; 111:1417-22. [PMID: 21864785 DOI: 10.1016/j.ultramic.2011.05.008] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Revised: 05/09/2011] [Accepted: 05/22/2011] [Indexed: 12/12/2022]
Affiliation(s)
- Xi Yang
- Nanomedicine Laboratory, China National Academy of Nanotechnology and Engineering, Tianjin 300457, China
| | | | | | | | | | | |
Collapse
|
44
|
Pellegrino M, Orsini P, Pellegrini M, Baschieri P, Dinelli F, Petracchi D, Tognoni E, Ascoli C. Weak hydrostatic forces in far-scanning ion conductance microscopy used to guide neuronal growth cones. Neurosci Res 2011; 69:234-40. [DOI: 10.1016/j.neures.2010.11.009] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2010] [Revised: 10/21/2010] [Accepted: 11/25/2010] [Indexed: 01/22/2023]
|
45
|
Rheinlaender J, Geisse NA, Proksch R, Schäffer TE. Comparison of scanning ion conductance microscopy with atomic force microscopy for cell imaging. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:697-704. [PMID: 21158392 DOI: 10.1021/la103275y] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We present the first direct comparison of scanning ion conductance microscopy (SICM) with atomic force microscopy (AFM) for cell imaging. By imaging the same fibroblast or myoblast cell with both technologies in series, we highlight their advantages and disadvantages with respect to cell imaging. The finite imaging force applied to the sample in AFM imaging results in a coupling of mechanical sample properties into the measured sample topography. For soft samples such as cells this leads to artifacts in the measured topography and to elastic deformation, which we demonstrate by imaging whole fixed cells and cell extensions at high resolution. SICM imaging, on the other hand, has a noncontact character and can provide the true topography of soft samples at a comparable resolution.
Collapse
Affiliation(s)
- Johannes Rheinlaender
- Institute of Applied Physics, University of Erlangen-Nuremberg, Staudtstr. 7, Bldg. A3, 91058 Erlangen, Germany
| | | | | | | |
Collapse
|
46
|
A boundary delimitation algorithm to approximate cell soma volumes of bipolar cells from topographical data obtained by scanning probe microscopy. BMC Bioinformatics 2010; 11:323. [PMID: 20550692 PMCID: PMC2912302 DOI: 10.1186/1471-2105-11-323] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2010] [Accepted: 06/15/2010] [Indexed: 11/25/2022] Open
Abstract
Background Cell volume determination plays a pivotal role in the investigation of the biophysical mechanisms underlying various cellular processes. Whereas light microscopy in principle enables one to obtain three dimensional data, the reconstruction of cell volume from z-stacks is a time consuming procedure. Thus, three dimensional topographic representations of cells are easier to obtain by scanning probe microscopical measurements. Results We present a method of separating the cell soma volume of bipolar cells in adherent cell cultures from the contributions of the cell processes from data obtained by scanning ion conductance microscopy. Soma volume changes between successive scans obtained from the same cell can then be computed even if the cell is changing its position within the observed area. We demonstrate that the estimation of the cell volume on the basis of the width and the length of a cell may lead to erroneous determination of cell volume changes. Conclusions We provide a new algorithm to repeatedly determine single cell soma volume and thus to quantify cell volume changes during cell movements occuring over a time range of hours.
Collapse
|