1
|
Tao Y, Zhuang W, Fan W, Zhou L, Fan L, Qin H, Zhu Y. Dual-functional silver nanoparticle-enhanced ZnO nanorods for improved reactive oxygen species generation and cancer treatment. iScience 2025; 28:111858. [PMID: 40017508 PMCID: PMC11867527 DOI: 10.1016/j.isci.2025.111858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 08/22/2024] [Accepted: 01/17/2025] [Indexed: 03/01/2025] Open
Abstract
Recent advancements in sonodynamic therapy (SDT) for cancer treatment have highlighted the potential of enhancing reactive oxygen species (ROS) generation and improving therapeutic outcomes. This study introduces zinc oxide (ZnO) nanorods (NRs) in situ loaded with silver nanoparticles (ZnO@Ag NRs), designed to optimize ROS production under ultrasound irradiation and offer significant advantages in tumor specificity and biosafety. The transmission electron microscopy and elemental mapping confirmed the consistent size and monodispersed Ag nanoparticle for ZnO@Ag NR. Sonodynamic properties showed that ZnO@Ag NRs produce higher singlet oxygen and hydroxyl radicals under ultrasound. In vitro studies demonstrated excellent biocompatibility and enhanced cell-killing effects of ZnO@Ag NRs on CT-26 cells, while in vivo results confirmed its superior anti-tumor efficacy and biosafety. Furthermore, the ZnO@Ag NRs' antibacterial properties were also confirmed, suggesting additional benefits in treating cancers associated with bacterial infections. Collectively, these findings establish ZnO@Ag NRs as a potent and safe agent for ultrasound-driven cancer therapy.
Collapse
Affiliation(s)
- Yichao Tao
- School of Medicine, Nantong University, Nantong 226001, China
- Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai 200072, China
- Zhangjiagang Hospital of Traditional Chinese Medicine, Suzhou 215600, China
| | - Wenbin Zhuang
- School of Medicine, Nantong University, Nantong 226001, China
- Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai 200072, China
| | - Wensi Fan
- Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai 200072, China
| | - Longxiang Zhou
- Department of General Surgery, Jinshan Central Hospital Affiliated to Shanghai University of Medicine & Health Sciences, No.147, Jiankang Road, Shanghai 201599, China
| | - Lihong Fan
- School of Medicine, Nantong University, Nantong 226001, China
- Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai 200072, China
| | - Huanlong Qin
- School of Medicine, Nantong University, Nantong 226001, China
- Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai 200072, China
| | - Yefei Zhu
- Department of Gastroenterology, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou 225001, China
| |
Collapse
|
2
|
Włodarski M, Nowak MP, Putkonen M, Nyga P, Norek M. Surface Modification of ZnO Nanotubes by Ag and Au Coatings of Variable Thickness: Systematic Analysis of the Factors Leading to UV Light Emission Enhancement. ACS OMEGA 2024; 9:1670-1682. [PMID: 38222608 PMCID: PMC10785295 DOI: 10.1021/acsomega.3c08253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 12/07/2023] [Accepted: 12/11/2023] [Indexed: 01/16/2024]
Abstract
Surface modification by plasmonic metals is one of the most promising ways to increase the band-to-band excitonic recombination in zinc oxide (ZnO) nanostructures. However, the metal-induced modulation of the UV light emission depends strongly on the production method, making it difficult to recognize the mechanism responsible for charge/energy transfer between the semiconductor and a metal. Therefore, in this study, the ZnO/Ag and Au hybrids were produced by the same, fully controlled experimental approach. ZnO nanotubes (NTs), fabricated by a template-assisted ALD synthesis, were coated by metals of variable mass thickness (1-6.5 nm thick) using the electron beam PVD technique. The deposited Ag and Au metals grew in the form of island films made of metallic nanoparticles (NPs). The size of the NPs and their size distribution decreased, while the spacing between the NPs increased as the mass of the deposited Ag and Au metals decreased. Systematic optical analysis allowed us to unravel a specific role of surface defects in ZnO NTs in the processes occurring at the ZnO/metal interface. The enhancement of the UV emission was observed only in the ZnO/Ag system. The phenomena were tentatively ascribed to the coupling between the defect-related (DL) excitonic recombination in ZnO and the localized surface plasmon resonance (LSPR) at the Ag NPs. However, the enhancement of UV light was observed only for a narrow range of Ag NP dimensions, indicating the great importance of the size and internanoparticle spacing in the plasmonic coupling. Moreover, the enhancement factors were much stronger in ZnO NTs characterized by robust DL-related emission before metal deposition. In contrast to Ag, Au coatings caused quenching of the UV emission from ZnO NTs, which was attributed to the uncoupling between the DL and LSP energies in this system and a possible formation of the ohmic contact between the Au metal and the ZnO.
Collapse
Affiliation(s)
- Maksymilian Włodarski
- Institute
of Optoelectronics, Military University of Technology, 2 Gen. Sylwestra Kaliskiego Str., 00-908 Warsaw, Poland
| | - Michał P. Nowak
- Institute
of Optoelectronics, Military University of Technology, 2 Gen. Sylwestra Kaliskiego Str., 00-908 Warsaw, Poland
| | - Matti Putkonen
- Department
of Chemistry, University of Helsinki, P.O. Box 55, FI-00014 Helsinki, Finland
| | - Piotr Nyga
- Institute
of Optoelectronics, Military University of Technology, 2 Gen. Sylwestra Kaliskiego Str., 00-908 Warsaw, Poland
| | - Małgorzata Norek
- Institute
of Materials Science and Engineering, Faculty of Advanced Technologies
and Chemistry, Military University of Technology, 2 Gen. Sylwestra Kaliskiego Str., 00-908 Warsaw, Poland
| |
Collapse
|
3
|
Sharu K, Chattopadhyay S, Prajapati KN, Mitra J. Leveraging plasmonic hot electrons to quench defect emission in metal-semiconductor nanostructured hybrids. J Chem Phys 2023; 159:244702. [PMID: 38146830 DOI: 10.1063/5.0171078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Accepted: 12/04/2023] [Indexed: 12/27/2023] Open
Abstract
Modeling light-matter interactions in hybrid plasmonic materials is vital to their widening relevance from optoelectronics to photocatalysis. Here, we explore photoluminescence (PL) from ZnO nanorods (ZNRs) embedded with gold nanoparticles (Au NPs). A progressive increase in Au NP concentration introduces significant structural disorder and defects in ZNRs, which paradoxically quenches defect related visible PL while intensifying the near band edge (NBE) emission. Under UV excitation, the simulated semi-classical model realizes PL from ZnO with sub-bandgap defect states, eliciting visible emissions that are absorbed by Au NPs to generate a non-equilibrium hot carrier distribution. The photo-stimulated hot carriers, transferred to ZnO, substantially modify its steady-state luminescence, reducing NBE emission lifetime and altering the abundance of ionized defect states, finally reducing visible emission. The simulations show that the change in the interfacial band bending at the Au-ZnO interface under optical illumination facilitates charge transfer between the components. This work provides a general foundation to observe and model the hot carrier dynamics and strong light-matter interactions in hybrid plasmonic systems.
Collapse
Affiliation(s)
- Kritika Sharu
- School of Physics, Indian Institute of Science Education and Research Thiruvananthapuram, Thiruvananthapuram, Kerala 695551, India
| | - Shashwata Chattopadhyay
- School of Physics, Indian Institute of Science Education and Research Thiruvananthapuram, Thiruvananthapuram, Kerala 695551, India
| | - K N Prajapati
- School of Physics, Indian Institute of Science Education and Research Thiruvananthapuram, Thiruvananthapuram, Kerala 695551, India
| | - J Mitra
- School of Physics, Indian Institute of Science Education and Research Thiruvananthapuram, Thiruvananthapuram, Kerala 695551, India
| |
Collapse
|
4
|
Lizunova AA, Malo D, Guzatov DV, Vlasov IS, Kameneva EI, Shuklov IA, Urazov MN, Ramanenka AA, Ivanov VV. Plasmon-Enhanced Ultraviolet Luminescence in Colloid Solutions and Nanostructures Based on Aluminum and ZnO Nanoparticles. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:4051. [PMID: 36432340 PMCID: PMC9696599 DOI: 10.3390/nano12224051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Revised: 11/07/2022] [Accepted: 11/14/2022] [Indexed: 06/16/2023]
Abstract
Aluminum nanoparticles attract scientific interest as a promising low-cost material with strong plasmon resonance in the ultraviolet region, which can be used in various fields of photonics. In this paper, for the first time, ultraviolet luminescence of zinc oxide nanoparticles in colloid solutions and nanostructure films in the presence of plasmonic aluminum nanoparticles 60 nm in size with a metal core and an aluminum oxide shell were studied. Mixture colloids of ZnO and Al nanoparticles in isopropyl alcohol solution with concentrations from 0.022 to 0.44 g/L and 0.057 to 0.00285 g/L, correspondingly, were investigated. The enhancement of up to 300% of ZnO emission at 377 nm in colloids mixtures with metal nanoparticles due to formation of Al-ZnO complex agglomerates was achieved. Plasmon nanostructures with different configurations of layers, such as Al on the surface of ZnO, ZnO on Al, sandwich-like structure and samples prepared from a colloidal mixture of ZnO and Al nanoparticles, were fabricated by microplotter printing. We demonstrated that photoluminescence can be boosted 2.4-fold in nanostructures prepared from a colloidal mixture of ZnO and Al nanoparticles, whereas the sandwich-like structure gave only 1.1 times the amplification of luminescence. Calculated theoretical models of photoluminescence enhancement of ideal and weak emitters near aluminum nanoparticles of different sizes showed comparable results with the obtained experimental data.
Collapse
Affiliation(s)
- Anna A. Lizunova
- Moscow Institute of Physics and Technology, National Research University, 141701 Dolgoprudny, Russia
| | - Dana Malo
- Moscow Institute of Physics and Technology, National Research University, 141701 Dolgoprudny, Russia
| | - Dmitry V. Guzatov
- Physico-Technical Department, Yanka Kupala State University of Grodno, Ozheshko Str. 22, 230023 Grodno, Belarus
| | - Ivan S. Vlasov
- Moscow Institute of Physics and Technology, National Research University, 141701 Dolgoprudny, Russia
| | - Ekaterina I. Kameneva
- Moscow Institute of Physics and Technology, National Research University, 141701 Dolgoprudny, Russia
| | - Ivan A. Shuklov
- Moscow Institute of Physics and Technology, National Research University, 141701 Dolgoprudny, Russia
| | - Maxim N. Urazov
- Moscow Institute of Physics and Technology, National Research University, 141701 Dolgoprudny, Russia
| | - Andrei A. Ramanenka
- B. I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Nezavisimosti Ave. 68-2, 220072 Minsk, Belarus
| | - Victor V. Ivanov
- Moscow Institute of Physics and Technology, National Research University, 141701 Dolgoprudny, Russia
| |
Collapse
|
5
|
Ma S, Wei H, Zhu H, Ling FCC, Wang X, Su S. Higher-Order Multiphoton Absorption Upconversion Lasing Based on ZnO/ZnMgO Multiple Quantum Wells. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:3073. [PMID: 36080110 PMCID: PMC9457886 DOI: 10.3390/nano12173073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 08/11/2022] [Accepted: 08/31/2022] [Indexed: 06/15/2023]
Abstract
In the progress of nonlinear optics, multiphoton absorption (MPA) upconversion lasing enables many vital applications in bioimaging, three-dimensional optical data storage, and photodynamic therapy. Here, efficient four-photon absorption upconversion lasing from the ZnO/ZnMgO multiple quantum wells (MQWs) at room temperature is realized. Moreover, the MPA upconversion lasing and third-harmonic generation peak generated in the MQWs under the excitation of a femtosecond (fs) laser pulse were observed concurrently, and the essential differences between each other were studied comprehensively. Compared with the ZnO film, the upconversion lasing peak of the ZnO/ZnMgO MQWs exhibits a clear blue shift. In addition, the four-photon absorption upconversion photoluminescence (PL) intensity was enhanced in the MQWs/Au nanoparticles (NPs) by the metal-localized surface plasmons (LSPs). The work paves the way for short-wavelength lasers by taking advantage of the high stability and large exciton binding energy of the MQWs' structures.
Collapse
Affiliation(s)
- Shushu Ma
- School of Semiconductor Science and Technology, South China Normal University, Foshan 528225, China
| | - Haiyuan Wei
- School of Physics, Sun Yat-Sen University, Guangzhou 510275, China
| | - Hai Zhu
- School of Physics, Sun Yat-Sen University, Guangzhou 510275, China
| | | | - Xianghu Wang
- School of Materials, Shanghai Dianji University, Shanghai 200245, China
| | - Shichen Su
- School of Semiconductor Science and Technology, South China Normal University, Foshan 528225, China
- Guangdong Engineering Research Center of Optoelectronic Functional Materials and Devices, Guangzhou 510631, China
| |
Collapse
|
6
|
Zhang Y, Yu J, Zhang H, Li Y, Wang L. Nanofibrous dressing: Potential alternative for fighting against antibiotic‐resistance wound infections. J Appl Polym Sci 2022. [DOI: 10.1002/app.52178] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Yingjie Zhang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles Donghua University Shanghai China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology Donghua University Shanghai China
| | - Juan Yu
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles Donghua University Shanghai China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology Donghua University Shanghai China
| | - Huiru Zhang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles Donghua University Shanghai China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology Donghua University Shanghai China
| | - Yan Li
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles Donghua University Shanghai China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology Donghua University Shanghai China
| | - Lu Wang
- Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles Donghua University Shanghai China
- Key Laboratory of Textile Industry for Biomedical Textile Materials and Technology Donghua University Shanghai China
| |
Collapse
|
7
|
Nirmal NK, Awasthi KK, John PJ. Hepatotoxicity of graphene oxide in Wistar rats. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:46367-46376. [PMID: 32632678 DOI: 10.1007/s11356-020-09953-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Accepted: 06/26/2020] [Indexed: 06/11/2023]
Abstract
Graphene oxide (GO) has a multitude of applications in areas of nanomedicine, electronics, textile, water purification, and catalysis among others. GO is relatively easier to manufacture and customize as compared with other carbon-based nanomaterials. In the present work, GO was administered intraperitoneally to adult Wistar rats in four incremental doses, i.e., 0.0 mg/kg (control), 0.4 mg/kg (low dose), 2.0 mg/kg (mid-dose), and 10.0 mg/kg (high dose). After 15 repeated doses over a period of 30 days, biochemical assays for alanine transaminase (ALT), aspartate transaminase (AST), alkaline phosphatase (ALP), catalase (CAT), and malondialdehyde (MDA) were carried out. Histopathological and morphometric analyses of liver and kidney were also performed. Results demonstrated dose-dependent toxicity of GO. General behavior and liver indices remained unaffected in the study. Serum levels of ALT, ALP, and AST were altered significantly in high-dose treated animals. Changes were found insignificant in the low- and mid-dose groups. Catalase activity in liver tissue homogenates was decreased in the high-dose group. MDA levels were found elevated in treated rats. Unlike control and low dose, mid- and high-dose treated rats exhibited varying degrees of histopathological changes like inflammation around the central vein and portal veins, vacuolations, hepatocytic injury, and near normal to abnormal hepatic sinusoids. These findings show that GO has considerable toxic potential to mammalian liver and thorough toxicity studies are needed before these nanosheets are used in biomedicine.
Collapse
Affiliation(s)
- Naresh K Nirmal
- Department of Zoology, University of Rajasthan, Jaipur, 302004, India
| | - Kumud K Awasthi
- Department of Life Sciences, Vivekananda Global University, Jaipur, 303012, India
| | - Placheril J John
- Department of Zoology, University of Rajasthan, Jaipur, 302004, India.
| |
Collapse
|
8
|
Chakraborty M, Mitra I, Roy AJ, Paul S, Mallick A, Das S, Saha A, Show B, Chakrabarti PK, Ganguly T. Contrasting spectroscopic response of human hemoglobin in presence of graphene oxides and its reduced form: Comparative approach with carbon quantum dots. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 247:119079. [PMID: 33120118 DOI: 10.1016/j.saa.2020.119079] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2020] [Revised: 09/29/2020] [Accepted: 10/10/2020] [Indexed: 06/11/2023]
Abstract
Recently, a considerable amount of research is being directed towards study of graphene oxide (GO) and its reduced form (RGO) since their exposed functional groups make them better candidates in nanobiotechnolgy. In order to assess their biocompatibility, the nature of interactions between Human Hemoglobin (HHb) and GO/RGO are monitored since a comparative spectroscopic approach towards understanding their nature of interactions has not been investigated previously. UV-vis spectroscopy reveals hyperchromicity for HHb-GO system and hypochromicity for HHb-RGO system in the region of absorption of tryptophan/tyrosine residues. Notably, although steady-state fluorescence static quenching of HHb for GO and enhancement of fluorescence for RGO is noticed, but average fluorescence-lifetime is remaining unchanged in presence of GO/RGO. Calorimetric data illustrates three-site and five-site binding model to be the best-fit model for GO and RGO respectively. Also, synchronous fluorescence quenching corresponding to alterations in microenvironment of tryptophan/ tyrosine residues is observed only in presence of GO. Likewise FTIR spectroscopy elucidates involvement of both amide I and amide II bond of HHb backbone through H-bonding interaction only for GO. Furthermore RLS spectra demonstrate an increase and a decrease in signal for GO and RGO respectively. Surprisingly, secondary structure of HHb is maintained upon interaction with both GO/RGO, as revealed by CD spectroscopy, thus supporting their potential application in biological microenvironment. Thus it appears that the spectroscopic properties of HHb upon interaction with GO is altered upon its reduction to RGO. Furthermore the role of HHb as good candidate for bimolecular interaction has been highlighted.
Collapse
Affiliation(s)
| | - Ishani Mitra
- Department of Physics, Jadavpur University, Kolkata 700032, India
| | - Arka J Roy
- School Bio-Science, Jadavpur University, Kolkata 700032, India
| | - Somnath Paul
- School of Laser Science and Engineering, Jadavpur University, Kolkata 700032, India
| | - Ayan Mallick
- Department of Physics, University of Burdwan, Burdwan, India
| | - Subrata Das
- Department of CSS, Indian Association for the Cultivation of Science, Kolkata 700032, India
| | - Abhijit Saha
- UGC-DAE Consortium for Scientific Research, III/LB-B Bidhannagar, Kolkata 700 098, India
| | | | | | - Tapan Ganguly
- School of Laser Science and Engineering, Jadavpur University, Kolkata 700032, India.
| |
Collapse
|
9
|
Hasan MS, Geza M, Petersen JB, Gadhamshetty V. Graphene oxide transport and retention in biochar media. CHEMOSPHERE 2021; 264:128397. [PMID: 33032229 DOI: 10.1016/j.chemosphere.2020.128397] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 09/11/2020] [Accepted: 09/20/2020] [Indexed: 06/11/2023]
Abstract
This study explores the use of biochar (BC), an inexpensive filtration media, for removing graphene oxide (GO) contaminants from the aquatic subsurface environments. Mass balance approaches and column dissection tests were used to analyze the retention behavior of GO in a series of model fixed-bed columns as a function of ionic strength (IS) and flowrate. The column based on the biochar media (BC) displayed 3.6-fold higher retention compared to the quartz sand (control). To overcome the challenges of unfavorable electrostatic interactions between GO and BC, we used a facile functionalization strategy to modify the BC surfaces with nanoscale zero-valent iron (BC-nZVI). The BC-nZVI (5:1, w/w) retained 2.6-fold higher amounts of GO compared with bare biochar. Furthermore, the performance of BC-nZVI increased with decreasing values of IS, attributed to the attachment of GO to nZVI where nZVI was partially dissolved by the presence of higher chloride ion at high IS. A better GO retention (86%) at higher IS was observed in BC where the GO was primarily retained due to the higher aggregation via straining.
Collapse
Affiliation(s)
- Md Sazadul Hasan
- Department of Civil and Environmental Engineering, South Dakota School of Mines and Technology, 501 East Saint Joseph Street, Rapid City, SD, 57701, United States
| | - Mengistu Geza
- Department of Civil and Environmental Engineering, South Dakota School of Mines and Technology, 501 East Saint Joseph Street, Rapid City, SD, 57701, United States.
| | - Jacob B Petersen
- Engineering and Mining Experiment Station, South Dakota School of Mines and Technology, 501 East Saint Joseph Street, Rapid City, SD, 57701, United States
| | - Venkataramana Gadhamshetty
- Department of Civil and Environmental Engineering, South Dakota School of Mines and Technology, 501 East Saint Joseph Street, Rapid City, SD, 57701, United States; 2-Dimensional Materials for Biofilm Engineering Science and Technology (2DBEST) Center, South Dakota School of Mines and Technology, 501 East Saint Joseph Street, Rapid City, SD, 57701, United States
| |
Collapse
|
10
|
Graphene Oxide Coatings as Tools to Prevent Microbial Biofilm Formation on Medical Device. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2020; 1282:21-35. [PMID: 31468360 DOI: 10.1007/5584_2019_434] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The clinical challenge on surface engineering of medical devices to prevent microorganisms adhesion and biofilm formation, has become an essential aspect for medical implants. Antibacterial properties of Graphene Oxide (GO) have been demonstrated across a broad spectrum of bacteria, and the different mechanisms of action with which this nanomaterial interacts with the microbial surface have been elucidated in detail. Innovative protective coatings based on graphene film and hydrogel could represent an innovative solution for the prevention of nosocomial pathogens colonization on implantable device. This brief review mainly focuses on the applications of graphene in nanomedicine with a particular deepening on the antibacterial properties of GO and GO-based nanomaterials. In order to evaluate the possible future applications of GO as an anti-biofilm coating material for medical devices, studies on the ability of graphene coated surface to prevent microbial adhesion are also discussed. A concise review on in vitro toxicity and in vivo safety is also presented.
Collapse
|
11
|
Mousavi SM, Low FW, Hashemi SA, Lai CW, Ghasemi Y, Soroshnia S, Savardashtaki A, Babapoor A, Pynadathu Rumjit N, Goh SM, Amin N, Tiong SK. Development of graphene based nanocomposites towards medical and biological applications. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2020; 48:1189-1205. [DOI: 10.1080/21691401.2020.1817052] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Seyyed Mojtaba Mousavi
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Foo Wah Low
- Institute of Sustainable Energy, Universiti Tenaga Nasional (The National Energy University), Jalan IKRAM-UNITEN, Kajang, Malaysia
| | - Seyyed Alireza Hashemi
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Chin Wei Lai
- Nanotechnology and Catalysis Research Centre (NANOCAT), Institute for Advanced Studies (IAS), University of Malaya (UM), Kuala Lumpur, Malaysia
| | - Younes Ghasemi
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Sadaf Soroshnia
- Department of Chemical Engineering, University of Mohaghegh Ardabili (UMA), Ardabil, Iran
| | - Amir Savardashtaki
- Department of Medical Biotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Aziz Babapoor
- Department of Chemical Engineering, University of Mohaghegh Ardabili (UMA), Ardabil, Iran
| | - Nelson Pynadathu Rumjit
- Nanotechnology and Catalysis Research Centre (NANOCAT), Institute for Advanced Studies (IAS), University of Malaya (UM), Kuala Lumpur, Malaysia
| | - Su Mei Goh
- College of Engineering, Universiti Tenaga Nasional (@The Energy University), Jalan IKRAM-UNITEN, Kajang, Malaysia
| | - Nowshad Amin
- Institute of Sustainable Energy, Universiti Tenaga Nasional (The National Energy University), Jalan IKRAM-UNITEN, Kajang, Malaysia
| | - Sieh Kiong Tiong
- Institute of Sustainable Energy, Universiti Tenaga Nasional (The National Energy University), Jalan IKRAM-UNITEN, Kajang, Malaysia
| |
Collapse
|
12
|
Xiaoli F, Qiyue C, Weihong G, Yaqing Z, Chen H, Junrong W, Longquan S. Toxicology data of graphene-family nanomaterials: an update. Arch Toxicol 2020; 94:1915-1939. [DOI: 10.1007/s00204-020-02717-2] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Accepted: 03/12/2020] [Indexed: 12/12/2022]
|
13
|
Anirudhan TS, Chithra Sekhar V, Athira VS. Graphene oxide based functionalized chitosan polyelectrolyte nanocomposite for targeted and pH responsive drug delivery. Int J Biol Macromol 2020; 150:468-479. [PMID: 32044367 DOI: 10.1016/j.ijbiomac.2020.02.053] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2019] [Revised: 01/21/2020] [Accepted: 02/06/2020] [Indexed: 12/16/2022]
Abstract
Graphene oxide (GO) was first modified to amine functionalized GO (AGO) and acts as a cationic polyelectrolyte. Chitosan (CS) was conjugated with folic acid (FA) through N, N´ -Dicyclohexylcarbodiimide coupling to form FA-CS. After this, itaconic acid and acrylic acid monomers are grafted to the hydroxyl group of CS using ethyleneglycol dimethacrylate as cross linker and potassium peroxydisulfate as an initiator to generate -COOH functional groups and forming chemically modified chitosan (CMCS). Further doxorubicin (DOX) loaded into the FA-CMCS/AGO through π-π stacking interactions. The resulting nanocomposite was characterized by FTIR, SEM, TEM, Raman, AFM, DLS and ZP. The drug loading capacity was as high as 95.0% and the drug release rate at pH 5.3 was significantly higher than that under physiological conditions of pH 7.4. Cell viability of L929, HeLa and MCF7 cells was studied. The studies suggest the drug carrier has potential clinical applications for anticancer drug delivery.
Collapse
Affiliation(s)
- T S Anirudhan
- Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom, Trivandrum 695 581, India.
| | - V Chithra Sekhar
- Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom, Trivandrum 695 581, India
| | - V S Athira
- Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom, Trivandrum 695 581, India
| |
Collapse
|
14
|
Samadian H, Salami MS, Jaymand M, Azarnezhad A, Najafi M, Barabadi H, Ahmadi A. Genotoxicity assessment of carbon-based nanomaterials; Have their unique physicochemical properties made them double-edged swords? MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH 2020; 783:108296. [DOI: 10.1016/j.mrrev.2020.108296] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Revised: 01/03/2020] [Accepted: 01/06/2020] [Indexed: 12/26/2022]
|
15
|
Lin J, Chen X, Huang P. Graphene-based nanomaterials for bioimaging. Adv Drug Deliv Rev 2016; 105:242-254. [PMID: 27233213 PMCID: PMC5039069 DOI: 10.1016/j.addr.2016.05.013] [Citation(s) in RCA: 184] [Impact Index Per Article: 20.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 04/15/2016] [Accepted: 05/17/2016] [Indexed: 12/12/2022]
Abstract
Graphene-based nanomaterials, due to their unique physicochemical properties, versatile surface functionalization, ultra-high surface area, and good biocompatibility, have attracted considerable interest in biomedical applications such as biosensors, drug delivery, bioimaging, theranostics, and so on. In this review, we will summarize the current advances in bioimaging of graphene-based nanomaterials, including graphene, graphene oxide (GO), reduced graphene oxide (rGO), graphene quantum dots (GQDs), and their derivatives. There are two methods to synthesize graphene-based nanomaterials: in situ synthesis and binding method. We will highlight the molecular imaging modalities including optical imaging (fluorescence (FL), two-photon FL, and Raman imaging), PET/SPECT (positron emission tomography/single photon emission computed tomography), MRI (magnetic resonance imaging), PAI (photoacoustic imaging), CT (computed tomography), and multimodal imaging. In the end, we will elaborate on the prospects and challenges of their future bioimaging applications.
Collapse
Affiliation(s)
- Jing Lin
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China
| | - Xiaoyuan Chen
- Laboratory of Molecular Imaging and Nanomedicine (LOMIN), National Institute of Biomedical Imaging and Bioengineering (NIBIB), National Institutes of Health, Bethesda, MD 20892, USA.
| | - Peng Huang
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen 518060, China.
| |
Collapse
|