1
|
Velleca A, Pournaras S, Bryk E, Vigorita V. Under-reporting by surgical pathologists in tissue removed during revision surgery for metal-on-metal arthroplasties. Ann Med Surg (Lond) 2024; 86:2432-2436. [PMID: 38694334 PMCID: PMC11060295 DOI: 10.1097/ms9.0000000000001911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Accepted: 02/25/2024] [Indexed: 05/04/2024] Open
Abstract
Although adverse local tissue reactions (ALTR) have been reported for metal-on-metal implants (MoM) requiring early revision surgery, no study has looked at the accuracy of surgical pathologists in diagnosing ALTR. This study aims to investigate the accuracy of reporting adverse local tissue reactions in tissue samples following revision surgery from metal-on-metal implants. The authors reviewed histology glass slides as well as the original pathology reports of tissue processed in revision arthroplasties in 23 cases. These samples were microscopically analyzed for tissue necrosis and cystic degeneration, the presence of metal particles, corrosion byproducts, membrane formation, histiocytic cells, lymphocytic cells, and vascular pathology. The authors' findings were then compared to their corresponding original pathology reports. The authors found consistent under-reporting of the tissue findings. Most importantly, 18 samples showed evidence of metal present compared to 2 samples on original pathology reporting. The authors found that 15 samples showed evidence of pathological membranous tissue compared to just 6 on original pathology reporting. While just 3 of the original pathology reports indicated the presence of areas of predominantly lymphocytic inflammatory cells, the authors found 13 examples of such areas. Although ALTR reactions have been described as a sequala of failed MoM, the authors' data suggest that ALTR may occur more frequently than previously described. Under-reported findings of ALTR deprive both the patient and orthopaedic surgeon of important information that can help guide further follow-up.
Collapse
Affiliation(s)
- Anthony Velleca
- SUNY Downstate Health Sciences University, College of Medicine
| | - Stephen Pournaras
- Department of Orthopedic Surgery, One Brooklyn Health System/Kingsbrook Jewish Medical Center, Brooklyn
| | - Eli Bryk
- Department of Orthopedic Surgery, New York-Presbyterian/Lower Manhattan Hospital, New York, NY
| | - Vincent Vigorita
- Department of Orthopedic Surgery, One Brooklyn Health System/Kingsbrook Jewish Medical Center, Brooklyn
| |
Collapse
|
2
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|
3
|
Mathew MT, Cheng KY, Sun Y, Barao VAR. The Progress in Tribocorrosion Research (2010-21): Focused on the Orthopedics and Dental Implants. JOURNAL OF BIO- AND TRIBO-CORROSION 2023; 9:48. [PMID: 38525435 PMCID: PMC10959289 DOI: 10.1007/s40735-023-00767-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2022] [Revised: 04/20/2023] [Accepted: 05/05/2023] [Indexed: 03/26/2024]
Abstract
Tribocorrosion is an integration of two areas-tribology and corrosion. It can be defined as the material degradation caused by the combined effect of corrosion and tribological process at the material interfaces. Significant development has occurred in the field of tribocorrosion over the past years. This development is due to its applications in various fields, such as aerospace, marine, biomedical, and space. Focusing on biomedical applications, tribocorrosion finds its applications in the implants used in cardiovascular, spine, orthopedics, trauma, and dental areas. It was reported that around 7.2 million Americans are living with joint implants. Implant surgery is a traumatic and expensive procedure. Tribocorrosion can affect the lifespan of the implants, thus leading to implant failure and a potential cause of revision surgery. Hence, it is essential to understand how tribocorrosion works, its interaction with the implants, and what procedures can be implemented to protect materials from tribocorrosion. This paper discusses how tribocorrosion research has evolved over the past 11 years (2010-2021). This is a comprehensive overview of tribocorrosion research in biomedical applications.
Collapse
Affiliation(s)
- Mathew T. Mathew
- Department of Biomedical Science, UIC College of Medicine, Rockford, IL 61107, USA
- Department of Biomedical Engineering, UIC, Chicago, IL 60612, USA
- Department of Restorative Dentistry, College of Dentistry, UIC, Chicago, IL 60612, USA
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612, USA
| | - Kai-yuan Cheng
- Department of Biomedical Science, UIC College of Medicine, Rockford, IL 61107, USA
| | - Yani Sun
- Department of Biomedical Science, UIC College of Medicine, Rockford, IL 61107, USA
| | - Valentim A. R. Barao
- Departament of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, Sao Paulo 13414-903, Brazil
| |
Collapse
|
4
|
Manthe J, Cheng KY, Bijukumar D, Barba M, Pourzal R, Neto M, Mathew MT. Hip implant modular junction: The role of CoCrMo alloy microstructure on fretting-corrosion. J Mech Behav Biomed Mater 2022; 134:105402. [PMID: 36041275 PMCID: PMC10507884 DOI: 10.1016/j.jmbbm.2022.105402] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 07/09/2022] [Accepted: 07/24/2022] [Indexed: 11/29/2022]
Abstract
Cobalt-chromium-molybdenum (CoCrMo) alloy is one of the most used metals in total hip replacement (THR) due to the alloy's superior corrosion qualities and biocompatibility. Over time these prostheses may undergo wear and corrosion processes in a synergistic process known as tribocorrosion. Implant retrieval studies have shown that damage patterns on THR modular junction surfaces indicating specifically in vivo fretting-corrosion to take place. To date, there have been no studies on the fretting-corrosion behaviors of CoCrMo alloy under the consideration of specific microstructural features. A custom-built flat-on-flat fretting-corrosion setup was utilized to test the synergistic tribocorrosion behavior of fretting-corrosion. The difference in microstructure was generated through the cutting orientations of the transverse and the longitudinal direction of the bar stock material, where the longitudinal cut exhibits a characteristic banded microstructure (banded group) and the transverse cut a homogenous microstructure (unbanded group). A three-electrode system was employed to monitor the induced currents. Two different types of electrolytes were used in the current study: 1. Bovine calf serum (BCS-30 g/L protein) (normal conditions) 2. BCS with Lipopolysaccharide (LPS, 0.15 μg/ml) (simulated infectious conditions). In the free potential mode, banded samples showed an increased potential compared to the unbanded samples. In potentiostatic conditions, the banded group also exhibited a higher induced current in both electrolyte environments, indicating more corrosion loss. Both Nyquist and Bode plots showed both orientations of metal becoming more corrosion resistant post-fretting when compared to pre-fretting data. The longitudinal group at OCP demonstrated a unique shape of the fretting-loop, which might be related to tribochemical reactions. Based on the mechanical, electrochemical, and surface characterization data, the transverse group (unbanded) microstructures demonstrates a higher resistance to fretting-corrosion damage.
Collapse
Affiliation(s)
- Jacob Manthe
- RMDR Lab, Department of Biomedical Sciences, University of Illinois College of Medicine, Rockford, IL, USA
| | - Kai Yuan Cheng
- RMDR Lab, Department of Biomedical Sciences, University of Illinois College of Medicine, Rockford, IL, USA
| | - Divya Bijukumar
- RMDR Lab, Department of Biomedical Sciences, University of Illinois College of Medicine, Rockford, IL, USA
| | | | - Robin Pourzal
- Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA
| | - Mozart Neto
- Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA
| | - Mathew T Mathew
- RMDR Lab, Department of Biomedical Sciences, University of Illinois College of Medicine, Rockford, IL, USA; Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA.
| |
Collapse
|
5
|
Long-term survivorship of an exchangeable-neck hip prosthesis with a Ti-alloy/Ti-alloy neck-stem junction. Arch Orthop Trauma Surg 2022; 143:3649-3657. [PMID: 36178493 DOI: 10.1007/s00402-022-04634-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 09/18/2022] [Indexed: 11/02/2022]
Abstract
INTRODUCTION Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck-stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship. MATERIALS AND METHODS Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis. RESULTS The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5-90.1; 857 hips at risk) and 96.9% (95%CI 96.0-97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8-12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively. CONCLUSION The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.
Collapse
|
6
|
Cannella A, Greco T, Polichetti C, De Martino I, Mascio A, Maccauro G, Perisano C. A Rare Case of Adverse Reaction to Metal Debris in a Ceramic-on-Ceramic Total Hip Replacement. J Funct Biomater 2022; 13:145. [PMID: 36135580 PMCID: PMC9501357 DOI: 10.3390/jfb13030145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 09/02/2022] [Accepted: 09/05/2022] [Indexed: 11/17/2022] Open
Abstract
Adverse Reaction to Metal Debris (ARMD) is one of the most frequent complications after Total Hip Replacement (THR) and often a cause of surgical revision. This is true especially for implants with Metal-on-Metal (MoM) and Large Diameter Heads (LDHs), which are frequently used to improve stability and reduce the risk of dislocation. However, ARMD is not exclusive to MoM replacement, as it can also occur in other implants such Ceramic-on-Ceramic (CoC), Metal-on-Polyethylene (MoP), and Ceramic-on-Polyethylene (CoP). In these non-MoM implants, ARMD is not caused by the tribo-corrosion between bearing surfaces but, rather, by the fretting at the interface between neck and stem of dissimilar metals. A case of a severe ARMD that happened to a 73-year-old female patient with CoC bearing THR at the right hip is presented in this case report. In this case, the ARMD was misdiagnosed for over a year, resulting in the development of a massive pseudotumor. The treatment of choice was a two-stage revision with the implant of a hip megaprosthesis. After more than 2 years of follow-up, complete recovery of hip Range of Motion (ROM) and normalization of chromium and cobalt levels in blood and urine were achieved. Despite the relatively short follow-up period, this can be considered a successful treatment of a major and misdiagnosed ARMD in a non-MoM hip replacement.
Collapse
Affiliation(s)
- Adriano Cannella
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Tommaso Greco
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Chiara Polichetti
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Ivan De Martino
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Antonio Mascio
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Giulio Maccauro
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Orthopedics and Trauma Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy
| | - Carlo Perisano
- Orthopedics and Trauma Surgery Unit, Department of Ageing, Neurosciences, Head-Neck and Orthopedics Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| |
Collapse
|
7
|
Movassaghi K, Patel A, Miller I, Levine BR. An Atypical Adverse Local Tissue Reaction After Ceramic-on-Ceramic Primary Total Hip Arthroplasty. Arthroplast Today 2022; 14:71-75. [PMID: 35252509 PMCID: PMC8889265 DOI: 10.1016/j.artd.2022.01.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 12/11/2021] [Accepted: 01/15/2022] [Indexed: 11/14/2022] Open
Abstract
Adverse local tissue reaction is an uncommon but frequently described complication after total hip arthroplasty (THA). It is most often associated with metal-on-metal hips and less frequently with metal-on-polyethylene implants as part of a mechanically assisted crevice corrosion process. In this report, we describe a rare case of an atypical adverse local tissue reaction in a patient with a ceramic-on-ceramic THA. Abrasive backside liner wear from a prominent screw head, failure of the liner locking mechanism, and liner fragmentation secondary to component-component impingement created an atypical mass and fluid collection leading to THA failure. This case demonstrates the importance of appropriate cup-liner positioning, thorough workup of pain after THA, and the ability of ceramic debris to cause an associated, atypical adverse local tissue reaction.
Collapse
|
8
|
Campbell P, Park S, Ebramzadeh E. Semi-quantitative histology confirms that the macrophage is the predominant cell type in metal-on-metal hip tissues. J Orthop Res 2022; 40:387-395. [PMID: 33749015 PMCID: PMC9292819 DOI: 10.1002/jor.25040] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 02/11/2021] [Accepted: 03/10/2021] [Indexed: 02/04/2023]
Abstract
Numerous studies have examined the histology of metal-on-metal hip tissues for evidence of a dose response to metal wear but have often reported inconclusive or contradictory findings. The aim of the present study was to address these discrepancies using multiple histological scoring methods to characterize the tissue features of one large group of revised metal-on-metal total hips. Periprosthetic tissues from 165 metal-on-metal hip revisions were examined for features of aseptic lymphocytic vasculitis associated lesions (ALVAL) as rated using two scoring systems as well as rankings for macrophage and lymphocyte numbers, intracellular wear debris and necrosis. Correlations between histological features and clinical variables including gender and time to revision and implant variables including articular surface wear volume or visual taper corrosion scores were examined. Both ALVAL scores reflected the macrophage dominated histology with average scores of 5.9/10 and 1.5/3. There was a statistically significant correlation between the original ALVAL score and wear rate per year (correlation coefficient = 0.17, p = .05) and a moderate correlation between the number of macrophages and wear particles and wear volume. There was no statistically significant correlation between wear and any other feature including lymphocytic inflammation or necrosis. Strong correlations between combined cup and ball wear volume and histological characteristics were not observed, although the number of macrophages was more closely correlated with wear than lymphocytes or necrosis.
Collapse
Affiliation(s)
- Patricia Campbell
- The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Department of Orthopaedic SurgeryOrthopaedic Institute for Children, UCLALos AngelesCaliforniaUSA
| | - Sang‐Hyun Park
- The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Department of Orthopaedic SurgeryOrthopaedic Institute for Children, UCLALos AngelesCaliforniaUSA
| | - Edward Ebramzadeh
- The J. Vernon Luck, Sr., M.D. Orthopaedic Research Center, Department of Orthopaedic SurgeryOrthopaedic Institute for Children, UCLALos AngelesCaliforniaUSA
| |
Collapse
|
9
|
Wolf S, Johannessen AC, Ellison P, Furnes O, Hallan G, Rogg K, Skarstein K, Høl PJ. Inflammatory tissue reactions around aseptically loose cemented hip prostheses: A retrieval study of the Spectron EF stem with Reflection All-Poly acetabular cup. J Biomed Mater Res B Appl Biomater 2022; 110:1624-1636. [PMID: 35099116 PMCID: PMC9303329 DOI: 10.1002/jbm.b.35023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 11/09/2021] [Accepted: 01/15/2022] [Indexed: 12/27/2022]
Abstract
The cemented Spectron EF stem in combination with the cemented non‐crosslinked Reflection All‐Poly cup showed a high rate of mid‐term aseptic loosening. However, the failure mechanisms are not fully known. We assessed the inflammatory tissue reactions and wear particles in periprosthetic tissues, implant wear and blood metal ion levels in 28 patients with failed implants. Histological analysis showed a macrophage pre‐dominant pattern with randomly distributed lymphocytes, with various amounts of neutrophils and giant cells. The number of different cell types in the tissue samples from patients in the cup group and in the stem group was similar. Wear particles, mainly ZrO2, CoCrMo, and polyethylene particles of different sizes and shapes, were associated with macrophages/giant cells, and total particle load/mm2 was higher in cases of stem loosening. The Spectron EF stems were heavily worn, abraded, and polished. Stem abrasion correlated with metal ion concentrations in blood. The median polyethylene wear rate of the Reflection cups was 0.23 mm/year. The high proximal roughness of the Spectron EF stem resulted in excessive cement wear during loosening. The resulting inflammatory tissue responses to the degradation products both from the cup and the stem led to massive osteolysis and subsequent implant loosening.
Collapse
Affiliation(s)
- Susann Wolf
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,National Institute of Occupational Health, Oslo, Norway
| | - Anne Christine Johannessen
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,Department of Pathology, Haukeland University Hospital, Bergen, Norway
| | - Peter Ellison
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Ove Furnes
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Geir Hallan
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Katharina Rogg
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Kathrine Skarstein
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,Department of Pathology, Haukeland University Hospital, Bergen, Norway
| | - Paul Johan Høl
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, University of Bergen, Bergen, Norway
| |
Collapse
|
10
|
Eltit F, Mohammad N, Medina I, Haegert A, Duncan CP, Garbuz DS, Greidanus NV, Masri BA, Ng TL, Wang R, Cox ME. Perivascular lymphocytic aggregates in hip prosthesis-associated adverse local tissue reactions demonstrate Th1 and Th2 activity and exhausted CD8 + cell responses. J Orthop Res 2021; 39:2581-2594. [PMID: 33506972 DOI: 10.1002/jor.24998] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 01/19/2021] [Accepted: 01/24/2021] [Indexed: 02/04/2023]
Abstract
Hip implants are a successful solution for osteoarthritis; however, some individuals with metal-on-metal (MoM) and metal-on-polyethylene (MoP) prosthetics develop adverse local tissue reactions (ALTRs). While MoM and MoP ALTRs are presumed to be delayed hypersensitivity reactions to corrosion products, MoM- and MoP-associated ALTRs present with different histological characteristics. We compared MoM- and MoP-associated ALTRs histopathology with cobalt and chromium levels in serum and synovial fluid. We analyzed the gene expression levels of leukocyte aggregates and synovial fluid chemokines/cytokines to resolve potential pathophysiologic differences. In addition, we classified ALTRs from 79 patients according to their leukocyte infiltrates as macrophage-dominant, mixed, and lymphocyte-dominant. Immune-related transcript profiles from lymphocyte-dominant MoM- and MoP-associated ALTR patients with perivascular lymphocytic aggregates were similar. Cell signatures indicated predominantly macrophage, Th1 and Th2 lymphocytic infiltrate, with strong exhausted CD8+ signature, and low Th17 and B cell, relative to healthy lymph nodes. Lymphocyte-dominant ALTR-associated synovial fluid contained higher levels of induced protein 10 (IP-10), interleukin-1 receptor antagonist (IL-1RN), IL-8, IL-6, IL-16, macrophage inflammatory protein 1 (MIP-1α), IL-18, MCP-2, and lower cell-attracting chemokine levels, when compared with prosthetic revisions lacking ALTRs. In addition, the higher levels of IP-10, IL-8, IL-6, MIP-1α, and MCP-2 were observed within the synovial fluid of the lymphocyte-dominant ALTRs relative to the macrophage-dominant ALTRs. Not all cytokines/chemokines were detected in the perivascular aggregate transcripts, suggesting the existence of other sources in the affected synovia. Our results support the hypothesis of common hypersensitivity pathogenesis in lymphocyte-dominant MoM and MoP ALTRs. The exhausted lymphocyte signature indicates chronic processes and an impaired immune response, although the cause of the persistent T-cell activation remains unclear. The cytokine/chemokine signature of lymphocyte-dominant-associated ATLRs may be of utility for diagnosing this more aggressive pathogenesis.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,Vancouver Prostate Centre, Vancouver, British Columbia, Canada
| | - Nissreen Mohammad
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | | | - Anne Haegert
- Vancouver Prostate Centre, Vancouver, British Columbia, Canada
| | - Clive P Duncan
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Donald S Garbuz
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada.,Centre for Hip Health and Mobility, Vancouver, British Columbia, Canada
| | - Nelson V Greidanus
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada
| | - Bassam A Masri
- Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada.,Centre for Hip Health and Mobility, Vancouver, British Columbia, Canada
| | - Tony L Ng
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada.,Centre for Hip Health and Mobility, Vancouver, British Columbia, Canada
| | - Michael E Cox
- Vancouver Prostate Centre, Vancouver, British Columbia, Canada.,Department of Urologic Sciences, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
11
|
Mihara M, Hirakawa K, Takayanagi S, Maekawa K, Kitagawa R, Sato T. Adverse Local Tissue Reaction and Late-Onset Eosinophilic Gastroenteritis After Primary Total Hip Arthroplasty: A Case Report. JBJS Case Connect 2021; 11:01709767-202112000-00060. [PMID: 34807887 DOI: 10.2106/jbjs.cc.21.00333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
CASE A 67-year-old woman suffered from chronic diarrhea at 10 years after right total hip arthroplasty. She also had a pseudotumor caused by an adverse local tissue reaction (ALTR) in her right pelvis. We performed revision arthroplasty, in part because we suspected the diarrhea may have been associated with the intrapelvic pseudotumor. She was later diagnosed with eosinophilic gastroenteritis (EGE). CONCLUSION Although these two diseases were thought be be related through a similar immune reaction, our patient's clinical course suggests that the ALTR and EGE were independent events.
Collapse
Affiliation(s)
- Masahiko Mihara
- Shonan Kamakura Joint Reconstruction Center, Kamakura, Japan
| | - Kazuo Hirakawa
- Shonan Kamakura Joint Reconstruction Center, Kamakura, Japan
| | | | - Kazunari Maekawa
- Division of Pathophysiology, Department of Pathology, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Ryuta Kitagawa
- Department of Gastroenterology, Juntendo University Nerima Hospital, Nerima City, Japan
| | - Toshifumi Sato
- Department of Gastroenterology, Juntendo University Nerima Hospital, Nerima City, Japan
| |
Collapse
|
12
|
Manjunath V, Badhe RV, McCoy M, Rynne J, Bhatti A, Segu A, Oral E, Jacobs JJ, Chastain P, Bijukumar D, Mathew MT. The role of Vitamin E in hip implant-related corrosion and toxicity: Initial outcome. J Mech Behav Biomed Mater 2021; 123:104769. [PMID: 34412025 PMCID: PMC10559727 DOI: 10.1016/j.jmbbm.2021.104769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 07/27/2021] [Accepted: 08/07/2021] [Indexed: 10/20/2022]
Abstract
In orthopedic healthcare, Total Hip Replacement (THR) is a common and effective solution to hip-related bone and joint diseases/fracture; however, corrosion of the hip implant and the release of degradation metal ions/particles can lead to early implant failure and pose potential toxicity risk for the surrounding tissues. The main objective of this work was to investigate the potential role of Vitamin E to minimize corrosion-related concerns from CoCrMo hip implants. The study focused on two questions (i) Can Vitamin E inhibit CoCrMo corrosion? and (ii) Does Vitamin E moderate the toxicity associated with the CoCrMo implant particles? In the study (i) the electrochemical experiments (ASTM G61) with different concentrations of Vitamin E (1, 2, 3 mg/ml against the control) were performed using normal saline and simulated synovial fluid (Bovine calf serum-BCS, 30 g/L protein, pH 7.4) as electrolytes. The polished CoCrMo disc (Ra 50 nm) was the working electrode. The findings suggested that both Vitamin E-Saline (45 ± 0.9%) and Vitamin E-BCS (91 ± 3%) solutions protected against implant corrosion at a Vitamin E concentration of 3 mg/ml, but Vitamin E-BCS showed protection at all Vitamin E (1-3 mg/ml) concentration levels. These results suggested that the Vitamin E and the protein present in the BCS imparted additive effects towards the electrochemical inhibition. In the study (ii) the role of Vitamin E in cytotoxicity inhibition was studied using a mouse neuroblastoma cell line (N2a) for CoCrMo particles and Cr ions separately. The CoCrMo particles were generated from a custom-built hip simulator. The alamarBlue assay results suggested that Vitamin E provides significant protection (85% and 75% proliferation) to N2a cells against CoCrMo particles and Cr ions, respectively at 1 μg/ml concentration, as compared to the control group. However, the results obtained from ROS expression and DNA fiber staining suggest that Vitamin E is only effective against CoCrMo degradation particles and not against Cr ions. In summary, the findings show that Vitamin E can minimize the corrosion processes and play a role in minimizing the potential toxicity associated with implants.
Collapse
Affiliation(s)
- Vikas Manjunath
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Ravindra V Badhe
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Maureen McCoy
- Department of Biochemistry, University of Illinois, Urbana-Champaign, IL, USA
| | - Josiah Rynne
- Department of Mechanical Science and Engineering, University of Illinois, Urbana-Champaign, IL, USA
| | - Aisha Bhatti
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Abhijith Segu
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Ebru Oral
- Department of Orthopedic Surgery, Harvard Medical School, Boston, MA, USA
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Paul Chastain
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Divya Bijukumar
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Mathew T Mathew
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA.
| |
Collapse
|
13
|
Matar HE, Porter PJ, Porter ML. Metal allergy in primary and revision total knee arthroplasty : a scoping review and evidence-based practical approach. Bone Jt Open 2021; 2:785-795. [PMID: 34587776 PMCID: PMC8558451 DOI: 10.1302/2633-1462.210.bjo-2021-0098.r1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Aims Metal allergy in knee arthroplasty patients is a controversial topic. We aimed to conduct a scoping review to clarify the management of metal allergy in primary and revision total knee arthroplasty (TKA). Methods Studies were identified by searching electronic databases: Cochrane Central Register of Controlled Trials, Ovid MEDLINE, and Embase, from their inception to November 2020, for studies evaluating TKA patients with metal hypersensitivity/allergy. All studies reporting on diagnosing or managing metal hypersensitivity in TKA were included. Data were extracted and summarized based on study design, study population, interventions and outcomes. A practical guide is then formulated based on the available evidence. Results We included 38 heterogeneous studies (two randomized controlled trials, six comparative studies, 19 case series, and 11 case reports). The evidence indicates that metal hypersensitivity is a rare complication with some histopathological features leading to pain and dissatisfaction with no reliable screening tests preoperatively. Hypoallergenic implants are viable alternatives for patients with self-reported/confirmed metal hypersensitivity if declared preoperatively; however, concerns remain over their long-term outcomes with ceramic implants outperforming titanium nitride-coated implants and informed consent is paramount. For patients presenting with painful TKA, metal hypersensitivity is a diagnosis of exclusion where patch skin testing, lymphocyte transformation test, and synovial biopsies are useful adjuncts before revision surgery is undertaken to hypoallergenic implants with shared decision-making and informed consent. Conclusion Using the limited available evidence in the literature, we provide a practical approach to metal hypersensitivity in TKA patients. Future national/registry-based studies are needed to identify the scale of metal hypersensitivity, agreed diagnostic criteria, and management strategies. Cite this article: Bone Jt Open 2021;2(10):785–795.
Collapse
Affiliation(s)
- Hosam E Matar
- Wrightington Hospital, Wigan, UK.,Nottingham Elective Orthopaedic Services, Nottingham University Hospital NHS Trust, Nottingham, UK
| | | | | |
Collapse
|
14
|
Eltit F, Noble J, Sharma M, Benam N, Haegert A, Bell RH, Simon F, Duncan CP, Garbuz DS, Greidanus NV, Masri BA, Ng TL, Wang R, Cox ME. Cobalt ions induce metabolic stress in synovial fibroblasts and secretion of cytokines/chemokines that may be diagnostic markers for adverse local tissue reactions to hip implants. Acta Biomater 2021; 131:581-594. [PMID: 34192572 DOI: 10.1016/j.actbio.2021.06.039] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 06/17/2021] [Accepted: 06/22/2021] [Indexed: 12/18/2022]
Abstract
Adverse local tissue reactions (ALTRs) are a prominent cause of hip implant failure. ALTRs are characterized by aseptic necrosis and leukocyte infiltration of synovial tissue. The prevalence of ALTRs in hips with failing metal implants, with highest rates occurring in patients with metal-on-metal articulations, suggests a role for CoCrMo corrosion in ALTR formation. Although hypersensitivity reactions are the most accepted etiology, the precise cellular mechanism driving ALTR pathogenesis remains enigmatic. Here we show that cobalt ions released by failing hip implants induce mitochondrial stress and cytokine secretion by synovial fibroblasts: the presumptive initiators of ALTR pathogenesis. We found that in-vitro treatment of synovial fibroblasts with cobalt, but not chromium, generated gene expression changes indicative of hypoxia and mitophagy responses also observed in ALTRs biopsies. Inflammatory factors secreted by cobalt-exposed synovial fibroblasts were among those most concentrated in ALTR synovial fluid. Furthermore, both conditioned media from cobalt-exposed synovial fibroblasts, and synovial fluid from ALTRs patients, elicit endothelial activation and monocyte migration. Finally, we identify the IL16/CTACK ratio in synovial fluid as a possible diagnostic marker of ALTRs. Our results provide evidence suggesting that metal ions induce cell stress in synovial fibroblasts that promote an inflammatory response consistent with initiating ALTR formation. STATEMENT OF SIGNIFICANCE: We demonstrate that the cytotoxic effects of cobalt ions on the synovial cells (fibroblast) is sufficient to trigger inflammation on hip joints with metal implants. Cobalt ions affect mitochondrial function, leading to the auto phagocytosis of mitochondria and trigger a hypoxic response. The cell's hypoxic response includes secretion of cytokines that are capable of trigger inflammation by activating blood vessels and enhancing leukocyte migration. Among the secreted cytokines is IL-16, which is highly concentrated in the synovial fluid of the patients with adverse local tissue reactions and could be use as diagnostic marker. In conclusion we define the cells of the hip joint as key players in triggering the adverse reactions to hip implants and providing biomarkers for early diagnosis of adverse reactions to hip implants.
Collapse
|
15
|
Bernardinello N, Petrarulo S, Balestro E, Cocconcelli E, Veltkamp M, Spagnolo P. Pulmonary Sarcoidosis: Diagnosis and Differential Diagnosis. Diagnostics (Basel) 2021; 11:diagnostics11091558. [PMID: 34573900 PMCID: PMC8472810 DOI: 10.3390/diagnostics11091558] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Revised: 08/11/2021] [Accepted: 08/25/2021] [Indexed: 12/14/2022] Open
Abstract
Sarcoidosis is a multisystem disorder of unknown origin and poorly understood pathogenesis that predominantly affects lungs and intrathoracic lymph nodes and is characterized by the presence of noncaseating granulomatous inflammation in involved organs. The disease is highly heterogeneous and can mimic a plethora of other disorders, making diagnosis a challenge even for experienced physicians. The evolution and severity of sarcoidosis are highly variable: many patients are asymptomatic and their disease course is generally benign with spontaneous resolution. However, up to one-third of patients develop chronic or progressive disease mainly due to pulmonary or cardiovascular complications that require long-term therapy. The diagnosis of sarcoidosis requires histopathological evidence of noncaseating granulomatous inflammation in one or more organs coupled with compatible clinical and radiological features and the exclusion of other causes of granulomatous inflammation; however, in the presence of typical disease manifestations such as Löfgren’s syndrome, Heerfordt’s syndrome, lupus pernio and asymptomatic bilateral and symmetrical hilar lymphadenopathy, the diagnosis can be established with high level of certainty on clinical grounds alone. This review critically examines the diagnostic approach to sarcoidosis and emphasizes the importance of a careful exclusion of alternative diagnoses.
Collapse
Affiliation(s)
- Nicol Bernardinello
- Respiratory Disease Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (N.B.); (S.P.); (E.B.); (E.C.)
| | - Simone Petrarulo
- Respiratory Disease Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (N.B.); (S.P.); (E.B.); (E.C.)
| | - Elisabetta Balestro
- Respiratory Disease Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (N.B.); (S.P.); (E.B.); (E.C.)
| | - Elisabetta Cocconcelli
- Respiratory Disease Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (N.B.); (S.P.); (E.B.); (E.C.)
| | - Marcel Veltkamp
- Department of Pulmonology, ILD Center of Excellence, St. Antonius Hospital, 3430 EM Nieuwegein, The Netherlands;
| | - Paolo Spagnolo
- Respiratory Disease Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (N.B.); (S.P.); (E.B.); (E.C.)
- Correspondence: ; Tel.: +39-049-8211272; Fax: +39-049-8213110
| |
Collapse
|
16
|
Perino G, De Martino I, Zhang L, Xia Z, Gallo J, Natu S, Langton D, Huber M, Rakow A, Schoon J, Gomez-Barrena E, Krenn V. The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty. EFORT Open Rev 2021; 6:399-419. [PMID: 34267931 PMCID: PMC8246109 DOI: 10.1302/2058-5241.6.210013] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The histopathological examination of the periprosthetic soft tissue and bone has contributed to the identification and description of the morphological features of adverse local tissue reactions (ALTR)/adverse reactions to metallic debris (ARMD). The need of a uniform vocabulary for all disciplines involved in the diagnosis and management of ALTR/ARMD and of clarification of the parameters used in the semi-quantitative scoring systems for their classification has been considered a pre-requisite for a meaningful interdisciplinary evaluation. This review of key terms used for ALTR/ARMD has resulted in the following outcomes: (a) pseudotumor is a descriptive term for ALTR/ARMD, classifiable in two main types according to its cellular composition defining its clinical course; (b) the substitution of the term metallosis with presence of metallic wear debris, since it cannot be used as a category of implant failure or histological diagnosis; (c) the term aseptic lymphocytic-dominated vasculitis- associated lesion (ALVAL) should be replaced due to the absence of a vasculitis with ALLTR/ALRMD for lymphocytic-predominant and AMLTR/AMRMD for macrophage-predominant reaction. This review of the histopathological classifications of ALTR/ARMD has resulted in the following outcomes: (a) distinction between cell death and tissue necrosis; (b) the association of corrosion metallic debris with adverse local lymphocytic reaction and tissue necrosis; (c) the importance of cell and particle debris for the viscosity and density of the lubricating synovial fluid; (d) a consensus classification of lymphocytic infiltrate in soft tissue and bone marrow; (e) evaluation of the macrophage infiltrate in soft tissues and bone marrow; (f) classification of macrophage induced osteolysis/aseptic loosening as a delayed type of ALTR/ARMD; (g) macrophage motility and migration as possible driving factor for osteolysis; (h) usefulness of the histopathological examination for the natural history of the adverse reactions, radiological correlation, post-marketing surveillance, and implant registries. The review of key terms used for the description and histopathological classification of ALTR/ARMD has resulted in a comprehensive, new standard for all disciplines involved in their diagnosis, clinical management, and long-term clinical follow-up.
Cite this article: EFORT Open Rev 2021;6:399-419. DOI: 10.1302/2058-5241.6.210013
Collapse
Affiliation(s)
- Giorgio Perino
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Ivan De Martino
- Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Lingxin Zhang
- Department of Pathology and Laboratory Medicine, Sinai Health System, Toronto, Canada
| | - Zhidao Xia
- Centre for Nanohealth, Swansea University Medical School, Singleton Park, Swansea, UK
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, University Hospital, Palacky University Olomouc, Czech Republic
| | - Shonali Natu
- Department of Pathology, University Hospital of North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK
| | - David Langton
- Orthopaedic Department, Freeman Hospital, Newcastle upon Tyne, UK
| | - Monika Huber
- Pathologisch-bakteriologisches Institut, Otto Wagner Spital, Wien, Austria
| | - Anastasia Rakow
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Janosch Schoon
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Enrique Gomez-Barrena
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario La Paz-IdiPAZ, Universidad Autónoma de Madrid, Madrid, Spain
| | - Veit Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik-GmbH, Trier, Germany
| |
Collapse
|
17
|
Büchner M, Cook RB, Dommann-Scherrer C, Meier C, Dommann A, Wahl P. It's worth cleaning - The examination of the female taper could identify a particular cause of trunnionosis at revision 16 years after total hip arthroplasty. J Mech Behav Biomed Mater 2021; 115:104304. [PMID: 33445103 DOI: 10.1016/j.jmbbm.2020.104304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 11/28/2020] [Accepted: 12/29/2020] [Indexed: 11/18/2022]
Abstract
Adverse reaction to metal debris (ARMD) is an issue in metal-on-metal (MoM) total hip replacements (THR). It mainly affects large-head MoM THR, whereas 28-32 mm MoM pairings are associated with low long-term revision rates. However, the bearing surface is not necessarily the only cause of metal debris. This report documents with advanced analysis of the retrievals a particular cause of trunnionosis in late failure of a small diameter MoM THR and illustrates the importance of cleaning of the taper when seating the head in THR. A 65-year-old patient was revised due to ARMD 16 years after small diameter MoM THR. Debridement and exchange of the inlay and the head had been performed through an anterior approach. While the cup and the outer surface of the head were accessible to direct analysis by an optical coordinate measuring machine, the female taper had to be analysed indirectly by measuring an imprint. Wear from the cup and the head was within expected low ranges. The analysis of the female taper identified bone fragments, which contributed to trunnionosis. Failure due to ARMD after MoM THR is not necessarily caused by the bearing, but can be due to trunnionosis. Bone fragments within the taper contact in this case highlight the importance of meticulous cleaning of the taper before seating the head, to avoid trunnionosis.
Collapse
Affiliation(s)
- Mara Büchner
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Richard B Cook
- National Centre for Advanced Tribology at Southampton, University of Southampton, Southampton, United Kingdom
| | | | - Christoph Meier
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland
| | - Alex Dommann
- EMPA Swiss Federal Laboratories for Material Science and Technology, St. Gallen, Switzerland; ARTORG Centre for Biomedical Engineering Research, University of Berne, Berne, Switzerland
| | - Peter Wahl
- Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
| |
Collapse
|
18
|
Salloum Z, Lehoux EA, Harper ME, Catelas I. Effects of cobalt and chromium ions on glycolytic flux and the stabilization of hypoxia-inducible factor-1α in macrophages in vitro. J Orthop Res 2021; 39:112-120. [PMID: 32462687 DOI: 10.1002/jor.24758] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 05/15/2020] [Accepted: 05/25/2020] [Indexed: 02/04/2023]
Abstract
Implant wear and corrosion have been associated with adverse tissue reactions that can lead to implant failure. Wear and corrosion products are therefore of great clinical concern. For example, Co2+ and Cr3+ originating from CoCrMo-based implants have been shown to induce a proinflammatory response in macrophages in vitro. Previous studies have also shown that the polarization of macrophages by some proinflammatory stimuli is associated with a hypoxia-inducible factor-1α (HIF-1α)-dependent metabolic shift from oxidative phosphorylation (OXPHOS) towards glycolysis. However, the potential of Co2+ and Cr3+ to induce this metabolic shift, which plays a determining role in the proinflammatory response of macrophages, remains largely unexplored. We recently demonstrated that Co2+ , but not Cr3+ , increased oxidative stress and decreased OXPHOS in RAW 264.7 murine macrophages. In the present study, we analyzed the effects of Co2+ and Cr3+ on glycolytic flux and HIF-1α stabilization in the same experimental model. Cells were exposed to 6 to 24 ppm Co2+ or 50 to 250 ppm Cr3+ . Glycolytic flux was determined by analyzing extracellular flux and lactate production, while HIF-1α stabilization was analyzed by immunoblotting. Results showed that Co2+ , and to a lesser extent Cr3+ , increased glycolytic flux; however, only Co2+ acted through HIF-1α stabilization. Overall, these results, together with our previous results showing that Co2+ increases oxidative stress and decreases OXPHOS, suggest that Co2+ (but not Cr3+ ) can induce a HIF-1α-dependent metabolic shift from OXPHOS towards glycolysis in macrophages. This metabolic shift may play an early and pivotal role in the inflammatory response induced by Co2+ in the periprosthetic environment.
Collapse
Affiliation(s)
- Zeina Salloum
- Department of Biochemistry, Microbiology, and Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Eric A Lehoux
- Department of Mechanical Engineering, Faculty of Engineering, University of Ottawa, Ottawa, Ontario, Canada
| | - Mary-Ellen Harper
- Department of Biochemistry, Microbiology, and Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.,Ottawa Institute of Systems Biology, University of Ottawa, Ottawa, Ontario, Canada
| | - Isabelle Catelas
- Department of Biochemistry, Microbiology, and Immunology, Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.,Department of Mechanical Engineering, Faculty of Engineering, University of Ottawa, Ottawa, Ontario, Canada.,Department of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
19
|
Radice S, Westrick J, Ebinger K, Mathew MT, Wimmer MA. In-vitro studies on cells and tissues in tribocorrosion processes: A systematic scoping review. ACTA ACUST UNITED AC 2020; 24. [PMID: 33015276 DOI: 10.1016/j.biotri.2020.100145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Tribocorrosion of implants has been widely addressed in the orthopedic and dental research fields. This study is a systematic scoping review about research methods that combine tribocorrosion tests with cells/tissues cultures, aimed to identify related current problems and future challenges. We used 4 different databases to identify 1022 records responding to an articulated keywords search-strategy. After removing the duplicates and the articles that didn't meet the search-criteria, we assessed 20 full-text articles for eligibility. Of the 20 eligible articles, we charted 8 records on cell cultures combined with tribocorrosion tests on implant materials (titanium, CoCrMo, and/or stainless steel). The year of publication ranged from 1991 to 2019. The cell line used was mostly murine. Two records used fretting tests, while 6 used reciprocating sliding with pin-on-disc tribometers. An electrochemical three-electrode setup was used in 4 records. We identified overall two experimental approaches: cells cultured on the metal (5 records), and cells cultured near the metal (3 records). Research activities on tribocorrosion processes in the presence of cells have been undertaken worldwide by a few groups. After a limited initial interest on this topic in the 1990's, research activities have restarted in the last decade, renewing the topic with technologically more advanced setups and analytical tools. We identified the main problems to be the lack of test reproducibility and wear particle characterization. We believe that the main challenges lay in the interdisciplinary approach, the inter-laboratory validation of experiments, and the interpretation of results, particularly in relation to potential clinical significance.
Collapse
Affiliation(s)
- S Radice
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison St., Chicago, IL 60612, USA
| | - J Westrick
- Library of Rush University Medical Center, 600 S. Paulina St., Chicago, IL 60612, USA
| | - K Ebinger
- Klinikum Garmisch-Partenkirche, Auenstraße 6, 82467 Garmisch-Partenkirchen, Germany
| | - M T Mathew
- College of Medicine at Rockford, University of Illinois, Department of Biomedical Sciences, 1601 Parkview Avenue, Rockford, IL 61107, USA
| | - M A Wimmer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison St., Chicago, IL 60612, USA
| |
Collapse
|
20
|
Hall DJ, Pourzal R, Jacobs JJ. What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty. J Arthroplasty 2020; 35:S55-S59. [PMID: 32005621 PMCID: PMC7239747 DOI: 10.1016/j.arth.2020.01.016] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/07/2020] [Indexed: 02/01/2023] Open
Abstract
Adverse local tissue reactions (ALTRs) were first associated with patients with failed metal-on-metal surface replacements and total hip arthroplasty (THA). However, an increasing number of cases of ALTR in metal-on-polyethylene (MOP) THA patients is being reported. Clinically, ALTR appears as benign, aseptic masses or bursae in the periprosthetic tissues. Histopathologically, ALTRs are distinguished by an intense lymphocyte infiltrate, destruction of the synovial surfaces, widespread necrosis, and fibrin exudate. Tribocorrosion of modular junctions appears to be the cause of ALTR in MOP patients. The various tribocorrosion damage modes occurring at modular junctions produce metal ions and a diversity of particulates in relation to size, chemical composition, and structure. The mechanisms by which these various products of tribocorrosion lead to ALTR are still a matter of considerable research. This review clarifies what constitutes ALTR, its relationship to implant factors, and highlights current methods for diagnosis and management of patients with ALTR in the setting of MOP THA.
Collapse
Affiliation(s)
- Deborah J Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Joshua J Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
21
|
Hobza M, Milde D, Slobodova Z, Gallo J. The number of lymphocytes increases in the periprosthetic tissues with increasing time of implant service in non-metal-on-metal total joint arthroplasties: A role of metallic byproducts? Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2020; 165:416-427. [PMID: 32435063 DOI: 10.5507/bp.2020.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Accepted: 04/27/2020] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND The objective of the study was to determine the association between periprosthetic concentrations of selected metals and changes induced in periprosthetic tissues (PT). METHODS PT from 24 patients with metal-on-polyethylene or ceramic-on-polyethylene total joint replacements (TJRs) were examined. Samples underwent histological examination including quantification of cellular populations. Determination of metals was performed according to the published methodology. Results were processed using correlation analysis and Principal Component Analysis (PCA), respectively. RESULTS Growing concentration of metals in the PT was found as a function of length of exposure (LoE). Differences in Ti, Co, Cr and V concentrations (per α = 0.05) depended on the type of alloy the implants were made from. On the contrary, the implant composition did not reflect in the different numbers of immune cells per 1 high power field, not even in distribution of the membrane type according to the Krenn classification. PCA revealed several clusters in dependence on the LoE, type of the membrane and presence of immune cells. High representation of lymphocytes in the PT was typical for clusters with the longest LoE while a higher representation of neutrophils was typical for a shorter time to reoperation. CONCLUSIONS Correlation between the LoE and concentrations of metals in its surroundings was demonstrated. However, the tissue image analysis cannot differentiate finer, potentially metal-induced tissue changes. Importantly, the tissues become more similar with an increasing LoE. We draw a conclusion about predominantly non-specific stimulation of the PT jointly by metal and polyethylene particles in non-metal-on-metal TJRs.
Collapse
Affiliation(s)
- Martin Hobza
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, I. P. Pavlova 6, 779 00, Olomouc, Czech Republic
| | - David Milde
- Department of Analytical Chemistry, Faculty of Science, Palacky University Olomouc, 17. listopadu 12, 771 46 Olomouc, Czech Republic
| | - Zuzana Slobodova
- Department of Clinical and Molecular Pathology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 3, Olomouc, Czech Republic
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, I. P. Pavlova 6, 779 00, Olomouc, Czech Republic
| |
Collapse
|
22
|
Carulli C, Sani G, Matassi F, Civinini R, Innocenti M. A Mid- to Long-Term Follow-Up Experience with a Specific Metal-on-Metal Total Hip Arthroplasty Design. JOINTS 2020; 7:91-97. [PMID: 34195536 PMCID: PMC8236331 DOI: 10.1055/s-0040-1710388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2017] [Accepted: 04/04/2020] [Indexed: 11/09/2022]
Abstract
Purrpose
Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution.
Methods
Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's
t
-test.
Results
The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups.
Conclusion
Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up.
Level of Evidence
This is a therapeutic case series, Level 4 study.
Collapse
Affiliation(s)
| | - Giacomo Sani
- Orthopaedic Clinic, University of Florence, Florence, Italy
| | | | | | | |
Collapse
|
23
|
Wang Q, Eltit F, Garbuz D, Duncan C, Masri B, Greidanus N, Wang R. CoCrMo metal release in metal‐on‐highly crosslinked polyethylene hip implants. J Biomed Mater Res B Appl Biomater 2020; 108:1213-1228. [DOI: 10.1002/jbm.b.34470] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 06/18/2019] [Accepted: 07/29/2019] [Indexed: 01/26/2023]
Affiliation(s)
- Qiong Wang
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| | - Felipe Eltit
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| | - Donald Garbuz
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Clive Duncan
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Bassam Masri
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Nelson Greidanus
- Department of OrthopaedicsUniversity of British Columbia Vancouver British Columbia Canada
| | - Rizhi Wang
- Department of Materials EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- School of Biomedical EngineeringUniversity of British Columbia Vancouver British Columbia Canada
- Centre for Hip Health and Mobility Vancouver British Columbia Canada
| |
Collapse
|
24
|
Keidel K, Thomsen M, Dierkes C, Haas H, Arnold I, Heller KD, Krenn V, Liebisch M, Otto M, Gehrke T, Krenn V. [Very rare cases of periprosthetic malignant neoplasms : Data from 4000 cases of endoprosthetic joint replacements from the histopathologic implant register]. DER ORTHOPADE 2020; 49:248-254. [PMID: 31784796 DOI: 10.1007/s00132-019-03839-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND In 2016, the AG 11 (work group for implant-material-intolerance) of the German society for Orthopaedics and Orthopaedic Surgery (DGOOC) created a histopathologic implant register (HIR). The goal was to conduct a retrospective data analysis based on the revised SLIM-consensus-classification, which defines eight different failure mechanisms. QUESTIONS The analysis of 4000 cases of endoprosthetic joint replacements addressed the following questions: 1. What is the frequency distribution of different SLIM-types? 2. How does durability of endoprosthetic joint replacements differ among SLIM-types? 3. What kind of periprosthetic malignant neoplasia can be detected and how often? RESULTS SLIM-type I was diagnosed in 1577 cases (n = 1577, 39.4%), SLIM-type II in 577 cases (n = 577; 14.4%), SLIM-type III in 146 cases (n = 146; 3,7%), SLIM-type IV in 1151 cases (n = 1151; 28.8%), SLIM-type V in 361 cases (n = 361; 9.0%), SLIM-type VI in 143 cases (n = 143; 3.6%), SLIM-type VII in 42 cases (n = 42; 1.0%), and SLIM-type VIII in 3 cases (n = 3; 0.075%). There was statistical significance in implant durability between the different SLIM types. Among the different reasons for endoprosthetic joint replacement failure, non-infectious causes have the biggest share at 81%, with SLIM-type I (39.5%), and SLIM-type IV (29.4%) being the predominant SLIM types. Three cases of periprosthetic malignant neoplasia (SLIM-type VIII) were detected: one case of small B lymphocytic lymphoma/BCLL (C85.9; ICD-O: 9670/3), one case of diffuse large B‑cell lymphoma/DLBCL (C83.3; ICD‑O 9680/3), and one case of anaplastic large cell lymphoma (C84.7; ICD-O: 9714/3), with the latter ones being the causes for joint replacement , which indicates that malignant neoplasia is a very rare cause of endoprosthetic joint replacement (n = 2; 0.05%). DISCUSSION These data are complete new, especially as concerns arthrofibrosis (SLIM-type V), adverse inflammatory reactions (SLIM-type VI), and the very rare cases of periprosthetic malignant neoplasia, SLIM-type VIII, as a reason for revision. Since neither the annual review (2017) of the EPRD, nor the national evaluation report (2017) of the IQTIG provide sufficient data, this indicates the relevance of the HIR of the AG 11 of the DGOOC.
Collapse
Affiliation(s)
- Kevin Keidel
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik GmbH, Max-Planck-Straße 5, 54296, Trier, Deutschland
| | - Marc Thomsen
- Klinik für Orthopädie und Unfallchirurgie, Baden-Baden, Deutschland
| | - Christian Dierkes
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik GmbH, Max-Planck-Straße 5, 54296, Trier, Deutschland
| | - Holger Haas
- Gemeinschaftskrankenhaus St. Elisabeth/St. Petrus/St. Johannes GmbH, Bonn, Deutschland
| | - Ingo Arnold
- Rotes Kreuz Krankenhaus Bremen gGmbH, Bremen, Deutschland
| | | | | | | | - Mike Otto
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik GmbH, Max-Planck-Straße 5, 54296, Trier, Deutschland
| | | | - Veit Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik GmbH, Max-Planck-Straße 5, 54296, Trier, Deutschland.
| |
Collapse
|
25
|
Hallab NJ, Jacobs JJ. Orthopedic Applications. Biomater Sci 2020. [DOI: 10.1016/b978-0-12-816137-1.00070-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
26
|
Goodman SB, Gallo J, Gibon E, Takagi M. Diagnosis and management of implant debris-associated inflammation. Expert Rev Med Devices 2020; 17:41-56. [PMID: 31810395 PMCID: PMC7254884 DOI: 10.1080/17434440.2020.1702024] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Accepted: 12/04/2019] [Indexed: 02/07/2023]
Abstract
Introduction: Total joint replacement is one of the most common, safe, and efficacious operations in all of surgery. However, one major long-standing and unresolved issue is the adverse biological reaction to byproducts of wear from the bearing surfaces and modular articulations. These inflammatory reactions are mediated by the innate and adaptive immune systems.Areas covered: We review the etiology and pathophysiology of implant debris-associated inflammation, the clinical presentation and detailed work-up of these cases, and the principles and outcomes of non-operative and operative management. Furthermore, we suggest future strategies for prevention and novel treatments of implant-related adverse biological reactions.Expert opinion: The generation of byproducts from joint replacements is inevitable, due to repetitive loading of the implants. A clear understanding of the relevant biological principles, clinical presentations, investigative measures and treatments for implant-associated inflammatory reactions and periprosthetic osteolysis will help identify and treat patients with this issue earlier and more effectively. Although progressive implant-associated osteolysis is currently a condition that is treated surgically, with further research, it is hoped that non-operative biological interventions could prolong the lifetime of joint replacements that are otherwise functional and still salvageable.
Collapse
Affiliation(s)
- Stuart B. Goodman
- Department of Orthopaedic Surgery, Stanford University, Redwood City, CA, USA
- Department of Bioengineering, Stanford University, Stanford, CA, USA
| | - Jiri Gallo
- Department of Orthopaedics, Palacký University Olomouc, Olomouc, Czech Republic
| | - Emmanuel Gibon
- Department of Orthopaedic Surgery, University of Florida, Gainesville, FL, USA
| | - Michiaki Takagi
- Department of Orthopaedic Surgery, Yamagata University, Yamagata, Japan
| |
Collapse
|
27
|
Goodman SB, Gallo J. Periprosthetic Osteolysis: Mechanisms, Prevention and Treatment. J Clin Med 2019; 8:E2091. [PMID: 31805704 PMCID: PMC6947309 DOI: 10.3390/jcm8122091] [Citation(s) in RCA: 127] [Impact Index Per Article: 25.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Revised: 11/28/2019] [Accepted: 11/29/2019] [Indexed: 02/06/2023] Open
Abstract
Clinical studies, as well as in vitro and in vivo experiments have demonstrated that byproducts from joint replacements induce an inflammatory reaction that can result in periprosthetic osteolysis (PPOL) and aseptic loosening (AL). Particle-stimulated macrophages and other cells release cytokines, chemokines, and other pro-inflammatory substances that perpetuate chronic inflammation, induce osteoclastic bone resorption and suppress bone formation. Differentiation, maturation, activation, and survival of osteoclasts at the bone-implant interface are under the control of the receptor activator of nuclear factor kappa-Β ligand (RANKL)-dependent pathways, and the transcription factors like nuclear factor κB (NF-κB) and activator protein-1 (AP-1). Mechanical factors such as prosthetic micromotion and oscillations in fluid pressures also contribute to PPOL. The treatment for progressive PPOL is only surgical. In order to mitigate ongoing loss of host bone, a number of non-operative approaches have been proposed. However, except for the use of bisphosphonates in selected cases, none are evidence based. To date, the most successful and effective approach to preventing PPOL is usage of wear-resistant bearing couples in combination with advanced implant designs, reducing the load of metallic and polymer particles. These innovations have significantly decreased the revision rate due to AL and PPOL in the last decade.
Collapse
Affiliation(s)
- Stuart B. Goodman
- Department of Orthopaedic Surgery, Stanford University, 450 Broadway St. M/C 6342, Redwood City, CA 94063, USA
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, I. P. Pavlova 6, 779 00 Olomouc, Czech Republic;
| |
Collapse
|
28
|
J Hill M, Qi B, Bayaniahangar R, Araban V, Bakhtiary Z, Doschak M, Goh B, Shokouhimehr M, Vali H, Presley J, Zadpoor A, Harris M, Abadi P, Mahmoudi M. Nanomaterials for bone tissue regeneration: updates and future perspectives. Nanomedicine (Lond) 2019; 14:2987-3006. [DOI: 10.2217/nnm-2018-0445] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Joint replacement and bone reconstructive surgeries are on the rise globally. Current strategies for implants and bone regeneration are associated with poor integration and healing resulting in repeated surgeries. A multidisciplinary approach involving basic biological sciences, tissue engineering, regenerative medicine and clinical research is required to overcome this problem. Considering the nanostructured nature of bone, expertise and resources available through recent advancements in nanobiotechnology enable researchers to design and fabricate devices and drug delivery systems at the nanoscale to be more compatible with the bone tissue environment. The focus of this review is to present the recent progress made in the rationale and design of nanomaterials for tissue engineering and drug delivery relevant to bone regeneration.
Collapse
Affiliation(s)
- Michael J Hill
- Department of Mechanical Engineering – Engineering Mechanics, Michigan Technological University, Houghton, MI 49931, USA
| | - Baowen Qi
- Center for Nanomedicine & Department of Anesthesiology, Brigham & Women's Hospital Harvard Medical School, Boston, MA 02115, USA
| | - Rasoul Bayaniahangar
- Department of Mechanical Engineering – Engineering Mechanics, Michigan Technological University, Houghton, MI 49931, USA
| | - Vida Araban
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Zahra Bakhtiary
- Research Center for Pharmaceutical Nanotechnology, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Michael R Doschak
- Faculty of Pharmacy & Pharmaceutical Sciences, University of Alberta, Edmonton, AB T6G 2R3, Canada
| | - Brian C Goh
- Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Mohammadreza Shokouhimehr
- Department of Materials Science & Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Hojatollah Vali
- Department of Anatomy & Cell Biology & Facility for Electron Microscopy Research, McGill University, Montreal, QC H3A 0G4, Canada
| | - John F Presley
- Department of Anatomy & Cell Biology & Facility for Electron Microscopy Research, McGill University, Montreal, QC H3A 0G4, Canada
| | - Amir A Zadpoor
- Department of Biomechanical Engineering, Delft University of Technology (TU Delft), Delft, The Netherlands
| | - Mitchel B Harris
- Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Parisa PSS Abadi
- Department of Mechanical Engineering – Engineering Mechanics, Michigan Technological University, Houghton, MI 49931, USA
| | - Morteza Mahmoudi
- Precision Health Program & Department of Radiology, Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
29
|
Chuang PJ, Swaminathan V, Pavlovsky L, Marquez-Catral L, Jones DL, Song L. Negative influence of biofilm on CoCrMo corrosion. J Biomed Mater Res A 2019; 107:2556-2566. [PMID: 31355999 DOI: 10.1002/jbm.a.36761] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 07/19/2019] [Accepted: 07/22/2019] [Indexed: 11/08/2022]
Abstract
Minimal studies exist investigating biofilm-induced corrosion of orthopaedic implants. This study investigates potential contributions of Pseudomonas aeruginosa and Staphylococcus aureus biofilms on corrosion resistance of CoCrMo under static and fretting conditions. Biofilms were cultured on CoCrMo coupons for either 4 weeks (static culture) or 6 days (fretting culture; pin-on-disk with a Ti6Al4V hemispherical tip pin). Morphology of biofilms and corrosion of coupon surfaces were analyzed via SEM. Open circuit potential and electrochemical impedance spectroscopy measurements were collected for corrosion performance evaluation. Results showed no visible corrosion on coupon surfaces in static culture, which suggests these biofilms alone do not induce severe corrosion under the conditions of this study. However, electrochemical data showed biofilm presence lowered coupon electrochemical impedance in static and fretting cultures, suggesting resistive and capacitive characteristics of the metal oxide-biofilm-media interface were altered. Under fretting, the P. aeruginosa group exhibited a distinct damage morphology and Co:Cr:Mo ratio within the wear scar when compared with S. aureus and the bacteria-free control. These differences suggest the presence of P. aeruginosa biofilms may negatively impact corrosion resistance at the fretting interface. Taken together these results demonstrate biofilms can contribute to implant corrosion by influencing the electrochemical impedance of implant metal surfaces.
Collapse
|
30
|
Papadimitriou-Olivgeri I, Brown JM, Kilpatrick AFR, Gill HS, Athanasou NA. Solochrome cyanine: A histological stain for cobalt-chromium wear particles in metal-on-metal periprosthetic tissues. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2019; 30:103. [PMID: 31493091 PMCID: PMC6731196 DOI: 10.1007/s10856-019-6304-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 08/23/2019] [Indexed: 06/10/2023]
Abstract
Metal-on-metal (MoM) hip arthroplasties produce abundant implant-derived wear debris composed mainly of cobalt (Co) and chromium (Cr). Cobalt-chromium (Co-Cr) wear particles are difficult to identify histologically and need to be distinguished from other wear particle types and endogenous components (e.g., haemosiderin, fibrin) which may be present in MoM periprosthetic tissues. In this study we sought to determine whether histological stains that have an affinity for metals are useful in identifying Co-Cr wear debris in MoM periprosthetic tissues. Histological sections of periprosthetic tissue from 30 failed MoM hip arthroplasties were stained with haematoxylin-eosin (HE), Solochrome Cyanine (SC), Solochrome Azurine (SA) and Perls' Prussian Blue (PB). Sections of periprosthetic tissue from 10 cases of non-MoM arthroplasties using other implant biomaterials, including titanium, ceramic, polymethylmethacrylate (PMMA) and ultra-high molecular weight polyethylene (UHMWP) were similarly analysed. Sections of 10 cases of haemosiderin-containing knee tenosynovial giant cell tumour (TSGCT) were also stained with HE, SC, SA and PB. In MoM periprosthetic tissues, SC stained metal debris in phagocytic macrophages and in the superficial necrotic zone which exhibited little or no trichrome staining for fibrin. In non-MoM periprosthetic tissues, UHMWP, PMMA, ceramic and titanium particles were not stained by SC. Prussian Blue, but not SC or SA, stained haemosiderin deposits in MoM periprosthetic tissues and TSGT. Our findings show that SC staining (most likely Cr-associated) is useful in distinguishing Co-Cr wear particles from other metal/non-metal wear particles types in histological preparations of periprosthetic tissue and that SC reliably distinguishes haemosiderin from Co-Cr wear debris.
Collapse
Affiliation(s)
- I Papadimitriou-Olivgeri
- Department of Histopathology, NDORMS, University of Oxford, Nuffield Orthopaedic Centre, Oxford, OX3 7HE, UK
| | - J M Brown
- Department of Histopathology, NDORMS, University of Oxford, Nuffield Orthopaedic Centre, Oxford, OX3 7HE, UK
| | - A F R Kilpatrick
- Chemistry Research Laboratory, Mansfield Road, Oxford, OX1 3TA, UK
| | - H S Gill
- Department of Mechanical Engineering, University of Bath, Bath, BA2 7AY, UK
| | - N A Athanasou
- Department of Histopathology, NDORMS, University of Oxford, Nuffield Orthopaedic Centre, Oxford, OX3 7HE, UK.
| |
Collapse
|
31
|
Reito A, Lehtovirta L, Parkkinen J, Eskelinen A. Histopathological patterns seen around failed metal‐on‐metal hip replacements: Cluster and latent class analysis of patterns of failure. J Biomed Mater Res B Appl Biomater 2019; 108:1085-1096. [DOI: 10.1002/jbm.b.34460] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 06/20/2019] [Accepted: 07/13/2019] [Indexed: 11/06/2022]
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement Tampere Finland
| | - Lari Lehtovirta
- Coxa Hospital for Joint Replacement Tampere Finland
- School of Medicine, Tampere University Tampere Finland
| | - Jyrki Parkkinen
- Coxa Hospital for Joint Replacement Tampere Finland
- Fimlab Laboratories Tampere Finland
| | | |
Collapse
|
32
|
Eltit F, Wang Q, Wang R. Mechanisms of Adverse Local Tissue Reactions to Hip Implants. Front Bioeng Biotechnol 2019; 7:176. [PMID: 31417898 PMCID: PMC6683860 DOI: 10.3389/fbioe.2019.00176] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/08/2019] [Indexed: 12/11/2022] Open
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|
33
|
Nyga A, Hart A, Tetley TD. Molecular analysis of HIF activation as a potential biomarker for adverse reaction to metal debris (ARMD) in tissue and blood samples. J Biomed Mater Res B Appl Biomater 2018; 107:1352-1362. [PMID: 30261121 DOI: 10.1002/jbm.b.34227] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 06/14/2018] [Accepted: 08/12/2018] [Indexed: 12/25/2022]
Abstract
We aimed to find a biomarker for patients with adverse reaction to metal debris (ARMD) due to a metal-on-metal (MoM) hip implant. First, we compared molecular markers of hypoxia-inducible factor (HIF) pathway activation (BNIP3, GLUT1, HO1, VEGF, and HIF1A) and inflammatory response (IL1B and COX2) in tissue from patients undergoing revision of MoM hip implant with tissue from patients undergoing primary hip replacement (PHR). Second, we compared blood levels of the above molecular markers and additional inflammatory markers: TNFA, IL18, CASPASE1, NFKB or IKB, and TLR1-4 mRNA in patients with non-failed MoM hips. We report the presence of increased expression of HIF-target genes in the periprosthetic tissue in MoM patients when compared to the PHR group. This suggests HIF pathway activation due to MoM debris and the potential of using HIF targets as a predictor of failure. Analysis of blood samples from nonoverlapping, nonfailed, MoM group showed significantly higher expression of COX2 mRNA and significant correlations between HIF1A and GLUT1 mRNA expressions, and between HIF1A mRNA and selection of inflammatory genes, including IL18, IKB, TLR1, and TLR4. HIF pathway activation in the periprosthetic tissue biopsies of patients with hip replacements may represent the first biomarker to identify early ARMD. Further studies investigating blood biomarkers could also prove beneficial in detecting ARMD that could lead to an early intervention and improved patient outcome after hip revision surgery. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1352-1362, 2019.
Collapse
Affiliation(s)
- Agata Nyga
- Department of Pharmacology and Toxicology, National Heart & Lung Institute, Imperial College London, London, UK
| | - Alister Hart
- Institute of Orthopaedics & Musculoskeletal Science, Royal National Orthopaedic Hospital, University College London, Stanmore, UK
| | - Teresa D Tetley
- Department of Pharmacology and Toxicology, National Heart & Lung Institute, Imperial College London, London, UK
| |
Collapse
|
34
|
Perino G, Sunitsch S, Huber M, Ramirez D, Gallo J, Vaculova J, Natu S, Kretzer JP, Müller S, Thomas P, Thomsen M, Krukemeyer MG, Resch H, Hügle T, Waldstein W, Böettner F, Gehrke T, Sesselmann S, Rüther W, Xia Z, Purdue E, Krenn V. Diagnostic guidelines for the histological particle algorithm in the periprosthetic neo-synovial tissue. BMC Clin Pathol 2018; 18:7. [PMID: 30158837 PMCID: PMC6109269 DOI: 10.1186/s12907-018-0074-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Accepted: 08/16/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND The identification of implant wear particles and non-implant related particles and the characterization of the inflammatory responses in the periprosthetic neo-synovial membrane, bone, and the synovial-like interface membrane (SLIM) play an important role for the evaluation of clinical outcome, correlation with radiological and implant retrieval studies, and understanding of the biological pathways contributing to implant failures in joint arthroplasty. The purpose of this study is to present a comprehensive histological particle algorithm (HPA) as a practical guide to particle identification at routine light microscopy examination. METHODS The cases used for particle analysis were selected retrospectively from the archives of two institutions and were representative of the implant wear and non-implant related particle spectrum. All particle categories were described according to their size, shape, colour and properties observed at light microscopy, under polarized light, and after histochemical stains when necessary. A unified range of particle size, defined as a measure of length only, is proposed for the wear particles with five classes for polyethylene (PE) particles and four classes for conventional and corrosion metallic particles and ceramic particles. RESULTS All implant wear and non-implant related particles were described and illustrated in detail by category. A particle scoring system for the periprosthetic tissue/SLIM is proposed as follows: 1) Wear particle identification at light microscopy with a two-step analysis at low (× 25, × 40, and × 100) and high magnification (× 200 and × 400); 2) Identification of the predominant wear particle type with size determination; 3) The presence of non-implant related endogenous and/or foreign particles. A guide for a comprehensive pathology report is also provided with sections for macroscopic and microscopic description, and diagnosis. CONCLUSIONS The HPA should be considered a standard for the histological analysis of periprosthetic neo-synovial membrane, bone, and SLIM. It provides a basic, standardized tool for the identification of implant wear and non-implant related particles at routine light microscopy examination and aims at reducing intra-observer and inter-observer variability to provide a common platform for multicentric implant retrieval/radiological/histological studies and valuable data for the risk assessment of implant performance for regional and national implant registries and government agencies.
Collapse
Affiliation(s)
- G. Perino
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 E 70th Street, New York, NY 10023 USA
| | - S. Sunitsch
- Medizinische Universität Graz, Institut für Pathologie, Graz, Austria
| | - M. Huber
- Pathologisch-bakteriologisches Institut, Otto Wagner Spital, Wien, Austria
| | - D. Ramirez
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, 535 E 70th Street, New York, NY 10023 USA
| | - J. Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, University Hospital, Palacky University Olomouc, Olomouc, Czech Republic
| | - J. Vaculova
- Department of Pathology, Fakultni Nemocnice Ostrava, Ostrava, Czech Republic
| | - S. Natu
- Department of Pathology, University hospital of North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK
| | - J. P. Kretzer
- Labor für Biomechanik und Implantat-Forschung, Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Heidelberg, Heidelberg, Germany
| | - S. Müller
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Trier, Germany
| | - P. Thomas
- LMU Klinik, Klinik und Poliklinik für Dermatologie und Allergologie, Munich, Germany
| | - M. Thomsen
- Baden-Baden Klinik, Baden-Baden, Germany
| | | | - H. Resch
- Universitätsklinik für Unfallchirurgie und Sporttraumatologie, Salzburg, Austria
| | - T. Hügle
- Hôpital Orthopédique, Lausanne, Switzerland
| | - W. Waldstein
- Medizinische Universität Wien, AKH-Wien, Universitätsklinik für Orthopädie, Wien, Austria
| | - F. Böettner
- Adult Reconstruction and Joint Replacement Division, Hospital for Special Surgery, New York, NY USA
| | - T. Gehrke
- Helios Endo-Klinik, Hamburg, Germany
| | - S. Sesselmann
- Orthopädische Universitätsklinik Erlangen, Erlangen, Germany
| | - W. Rüther
- Klinik und Poliklinik für Orthopädie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| | - Z. Xia
- Centre for Nanohealth, Swansea University Medical School, Singleton Park, Swansea, UK
| | - E. Purdue
- Hospital for Special Surgery, Research Institute, New York, NY USA
| | - V. Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik, Trier, Germany
| |
Collapse
|
35
|
Marinier M, Edmiston TA, Kearns S, Hannon CP, Levine BR. A Survey of the Prevalence of and Techniques to Prevent Trunnionosis. Orthopedics 2018; 41:e557-e562. [PMID: 29813167 DOI: 10.3928/01477447-20180524-03] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 03/08/2018] [Indexed: 02/03/2023]
Abstract
Trunnionosis of total hip arthroplasty (THA) components has been an increasingly reported complication. Consensus is lacking regarding preventive practices and the overall incidence of trunnionosis. In this study, fellowship-trained adult reconstruction orthopedic surgeons were surveyed to identify expert opinions. A 25-question, web-based survey regarding trunnionosis incidence, prevention, and biomaterials was sent to 345 fellowship-trained adult reconstruction orthopedic surgeons in North America. The survey yielded 151 (43.8%) responses from surgeons with a mean of 11.97±9.49 years of experience. These surgeons believe that the material composite of the head-neck junction is the most important contributor to trunnionosis. They often choose a ceramic head with a metal alloy stem to reduce trunnionosis. They more commonly impact the femoral head 3 times than once. Fifty-one percent believe that trunnionosis leads to THA failure for between 0% and 2% of all THA revisions, whereas 48.3% believe that the failure rate is greater than 2%. More than half (53.6%) of these surgeons recommend a revision THA if a patient's serum cobalt level is greater than 10 µg/L, regardless of symptom presence. The incidence of trunnionosis appears to be increasing due to changes in implants and/or an increased awareness of the problem, with 48.3% of these surgeons believing that trunnionosis is the primary cause of THA failure for more than 1 in 50 patients. Some suggested preventive measures include cleaning and drying the trunnion, using ceramic femoral heads, matching THA components, and adding titanium sleeves on well-fixed stems that are retained during revision surgery. [Orthopedics. 2018; 41(4):e557-e562.].
Collapse
|
36
|
Bijukumar DR, Segu A, Souza JCM, Li X, Barba M, Mercuri LG, J Jacobs J, Mathew MT. Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2018; 14:951-963. [PMID: 29339190 PMCID: PMC6017990 DOI: 10.1016/j.nano.2018.01.001] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 12/22/2017] [Accepted: 01/02/2018] [Indexed: 12/12/2022]
Abstract
Despite the technological improvements in orthopedic joint replacement implants, wear and corrosion products associated with the metal components of these implants may result in adverse local tissue and perhaps systemic reactions and toxicities. The current review encompasses a literature review of the local and systemic toxicity studies concerning the effect of CoCrMo wear debris released from wear and corrosion of orthopedic implants and prostheses. Release of metallic debris is mainly in the form of micro- and nano-particles, ions of different valences, and oxides composed of Co and Cr. Though these substances alter human biology, their direct effects of these substances on specific tissue types remain poorly understood. This may partially be the consequence of the multivariate research methodologies employed, leading to inconsistent reports. This review proposes the importance of developing new and more appropriate in-vitro methodologies to study the cellular responses and toxicity mediated by joint replacement wear debris in-vivo.
Collapse
Affiliation(s)
- Divya Rani Bijukumar
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA
| | - Abhijith Segu
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA
| | - Júlio C M Souza
- Center for MicroElectromechanical Systems (CMEMS-UMINHO), University of Minho, Guimaraes, Portugal
| | - XueJun Li
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA
| | - Mark Barba
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA; OrthoIllinois, Rockford, IL, USA
| | - Louis G Mercuri
- Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA
| | - Joshua J Jacobs
- Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA
| | - Mathew Thoppil Mathew
- Regenerative Medicine and Disability Research Lab, Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, IL, USA; Department of Orthopedics, Rush University Medical Center, Chicago, IL, USA; Department of Bioengineering, University of Illinois at Chicago, IL, USA.
| |
Collapse
|
37
|
Steffen JE, Fassler EA, Reardon KJ, Egilman DS. Grave fraudulence in medical device research: a narrative review of the PIN seeding study for the Pinnacle hip system. Account Res 2017; 25:37-66. [DOI: 10.1080/08989621.2017.1405259] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
| | | | | | - David S. Egilman
- Department of Family Medicine, Brown University, Attleboro, Massachusetts, USA
| |
Collapse
|
38
|
Lehtovirta L, Reito A, Parkkinen J, Hothi H, Henckel J, Hart A, Eskelinen A. Analysis of bearing wear, whole blood and synovial fluid metal ion concentrations and histopathological findings in patients with failed ASR hip resurfacings. BMC Musculoskelet Disord 2017; 18:523. [PMID: 29228956 PMCID: PMC5725985 DOI: 10.1186/s12891-017-1894-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 12/04/2017] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Adverse Reaction to Metal Debris (ARMD) is still a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. ARMD consists of a wide range of alterations in periprosthetic tissues, most important of which are metallosis, inflammation, pseudotumors and necrosis. Studies investigating histopathological findings and their association to implant wear or indirect measures of wear have yielded inconsistent results. Therefore, we aimed to investigate bearing surface wear volume, whole blood and synovial fluid metal ion concentrations, histopathological findings in periprosthetic tissues and their associations. METHODS Seventy-eight patients with 85 hips revised for ARMD were included in the study. Prior to revision surgery, all patients had whole blood chromium and cobalt ion levels assessed. In revision surgery, a synovial fluid sample was taken and analyzed for chromium and cobalt. Periprosthetic tissue samples were taken and analyzed for histopathological findings. Explanted implants were analyzed for bearing wear volume of both acetabular cup and femoral head components. RESULTS Volumetric wear of the failed components was highly variable. The total wear volume of the head and cup had a strong correlation with whole blood chromium and cobalt ion concentrations (Cr: ρ = 0.80, p < 0.001 and Co: ρ = 0.84, p < 0.001) and a bit weaker correlation with fluid chromium and cobalt ion concentrations (Cr: ρ = 0.50, p < 0.01 and Co: ρ = 0.41, p = 0.027). Most tissues displayed only low-to-moderate amounts of macrophages and lymphocytes. Total wear volume correlated with macrophage sheet thickness (ρ = 0.25, p = 0.020) and necrosis (ρ = 0.35, p < 0.01). Whole blood chromium and cobalt ion concentrations had similar correlations. Lymphocyte cuff thickness did not correlate with either total wear volume or whole blood metal ion concentrations, but correlated with the grade of necrosis. CONCLUSIONS Bearing wear volume correlated with blood metal ion levels and the degree of necrosis and macrophage infiltration in periprosthetic tissues suggesting a dose-response relationship. Whole blood metal ion levels are a useful tool for clinician to estimate bearing wear and subsequent tissue response.
Collapse
Affiliation(s)
- Lari Lehtovirta
- Faculty of Medicine, University of Tampere, Tampere, Finland
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | | | | | | |
Collapse
|
39
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
40
|
Hopf F, Thomas P, Sesselmann S, Thomsen MN, Hopf M, Hopf J, Krukemeyer MG, Resch H, Krenn V. CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing. Acta Orthop 2017; 88:642-648. [PMID: 28787254 PMCID: PMC5694809 DOI: 10.1080/17453674.2017.1362774] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - The most frequent cause of arthroplasty failure is aseptic loosening-often induced by particles. Abrasion material triggers inflammatory reactions with lymphocytic infiltration and the formation of synovial-like interface membranes (SLIM) in the bone-implant interface. We analyzed CD3 quantities in SLIM depending on articulating materials and possible influences of proven material allergies on CD3 quantities. Patients and methods - 222 SLIM probes were obtained from revision surgeries of loosened hip and knee arthroplasties. SLIM cases were categorized according to the SLIM-consensus classification and to the particle algorithm. The CD3 quantities were analyzed immunohistochemically, quantified, and correlated to the particle types. Results - Metal-metal pairings showed the highest CD3 quantities (mean 1,367 counted cells). CD3 quantities of metal-polyethylene (mean 243), ceramic-polyethylene (mean 182), and ceramic-ceramic pairings (mean 124) were significantly smaller. Patients with contact allergy to implant materials had high but not statistically significantly higher CD3 quantities than patients without allergies. For objective assessment of the CD3 response as result of a pronounced inflammatory reaction with high lymphocytosis (adverse reaction), a defined CD3 quantity per high power field was established, the "CD3 focus score" (447 cells/0.3 mm2, sensitivity 0.92; specificity 0.90; positive predictive value 0.71; negative predictive value 0.98). Interpretation - The high CD3 quantities for metal-metal pairings may be interpreted as substrate for previously described adverse reactions that cause severe peri-implant tissue destruction and SLIM formation. It remains unclear whether the low CD3 quantities with only slight differences in the various non-metal-metal pairings and documented contact allergies to implant materials have a direct pathogenetic relevance.
Collapse
Affiliation(s)
- Felix Hopf
- Center for Histopathology and Molecular Pathology, Trier, Germany
| | - Peter Thomas
- Department of Dermatology and Allergologie, Ludwig-Maximilians-University (LMU), Munich, Germany
| | - Stefan Sesselmann
- Department of Orthopaedic Surgery, Friedrich-Alexander-University of Erlangen-Nuremberg, Germany,Correspondence:
| | - Marc N Thomsen
- Clinic of Orthopaedic Medicine and Emergency Surgery, Klinikum Mittelbaden Baden-Baden Balg, Baden-Baden, Germany
| | - Maximilian Hopf
- Center for Histopathology and Molecular Pathology, Trier, Germany
| | - Johannes Hopf
- Department of Orthopaedics and Traumatology, Johannes Gutenberg University, Mainz, Germany
| | | | - Herbert Resch
- University Hospital for Trauma Surgery and Sports Traumatology, Salzburg, Austria
| | - Veit Krenn
- Center for Histopathology and Molecular Pathology, Trier, Germany
| |
Collapse
|
41
|
Vaculova J, Gallo J, Hurnik P, Motyka O, Goodman SB, Dvorackova J. Low intrapatient variability of histomorphological findings in periprosthetic tissues from revised metal/ceramic on polyethylene joint arthroplasties. J Biomed Mater Res B Appl Biomater 2017; 106:2008-2018. [PMID: 29044940 DOI: 10.1002/jbm.b.33990] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2016] [Revised: 07/25/2017] [Accepted: 08/30/2017] [Indexed: 11/05/2022]
Abstract
The type of tissue response to implant by-products can be determined by examination of periprosthetic tissues. However, little is known about the most suitable location for tissue sampling. The main goal of this study was to evaluate the extent of variability in tissue response in relation to location of tissue sampling, implant fixation, age and sex in total joint arthroplasties with metal-on-polyethylene or ceramic-on-polyethylene bearing pairs. We processed 236 histology slides from 21 patients and focused on the association between the location of tissue samples and histological features. The presence of the synovial hyperplasia showed a significant association with the particular sampling site. A higher density of high endothelial cell venules was seen in the samples from around the joint, and polyethylene particles were more abundant in noncemented TJA but both findings did not show statistically significant association with the sampling site. The results showed a relatively small variance in the tissue response to prosthetic by-products among tissues sampled from the same patient. Our findings indicate that tissue samples retrieved from similar distance from around the TJA during the revision operation show comparable results of histological analysis. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2008-2018, 2018.
Collapse
Affiliation(s)
- Jana Vaculova
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic.,Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic
| | - Pavel Hurnik
- Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic.,CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic
| | - Oldrich Motyka
- Nanotechnology Centre, VŠB - Technical University of Ostrava, Ostrava-Poruba, 708 33, Czech Republic
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford Medical Center Outpatient Clinic, Redwood City, CA, 94063
| | - Jana Dvorackova
- Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic.,CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic
| |
Collapse
|
42
|
Di Laura A, Quinn PD, Panagiotopoulou VC, Hothi HS, Henckel J, Powell JJ, Berisha F, Amary F, Mosselmans JFW, Skinner JA, Hart AJ. The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue. Sci Rep 2017; 7:10952. [PMID: 28887488 PMCID: PMC5591307 DOI: 10.1038/s41598-017-11225-w] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Accepted: 08/21/2017] [Indexed: 02/08/2023] Open
Abstract
The mechanisms of metal release from the articulation at the head cup bearing and the tapered junctions of orthopaedic hip implants are known to differ and the debris generated varies in size, shape and volume. Significantly less metal is lost from the taper junction between Cobalt-Chromium-Molybdenum (CoCrMo) and Titanium (Ti) components (fretting-corrosion dominant mechanism), when compared to the CoCrMo bearing surfaces (wear-corrosion dominant mechanism). Corrosion particles from the taper junction can lead to Adverse Reactions to Metal Debris (ARMD) similar to those seen with CoCrMo bearings. We used synchrotron methods to understand the modes underlying clinically significant tissue reactions to Co, Cr and Ti by analysing viable peri-prosthetic tissue. Cr was present as Cr2O3 in the corroded group in addition to CrPO4 found in the metal-on-metal (MoM) group. Interestingly, Ti was present as TiO2 in an amorphous rather than rutile or anatase physical form. The metal species were co-localized in the same micron-scale particles as result of corrosion processes and in one cell type, the phagocytes. This work gives new insights into the degradation products from metal devices as well as guidance for toxicological studies in humans.
Collapse
Affiliation(s)
- Anna Di Laura
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom.
| | - Paul D Quinn
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, United Kingdom
| | - Vasiliki C Panagiotopoulou
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Harry S Hothi
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Johann Henckel
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Jonathan J Powell
- Biomineral Research Group, Dept Veterinary Medicine, University of Cambridge, Cambridge, United Kingdom
| | - Fitim Berisha
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Fernanda Amary
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - J Fred W Mosselmans
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, United Kingdom
| | - John A Skinner
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| | - Alister J Hart
- Institute of Orthopaedics and Musculoskeletal Science, University College London and the Royal National Orthopaedic Hospital, Stanmore, United Kingdom
| |
Collapse
|
43
|
Urish KL, Hamlin BR, Plakseychuk AY, Levison TJ, Higgs G, Kurtz S, DiGioia AM. Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head. J Arthroplasty 2017; 32:2857-2863. [PMID: 28478184 PMCID: PMC5572503 DOI: 10.1016/j.arth.2017.03.075] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Revised: 03/11/2017] [Accepted: 03/31/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Gross trunnion failure (GTF) is a rare complication in total hip arthroplasty (THA) reported across a range of manufacturers. Specific lots of the Stryker low friction ion treatment (LFIT) anatomic cobalt chromium alloy (CoCr) V40 femoral head were recalled in August 2016. In part, the recall was based out of concerns for disassociation of the femoral head from the stem and GTF. METHODS We report on 28 patients (30 implants) with either GTF (n = 18) or head-neck taper corrosion (n = 12) of the LFIT CoCr femoral head and the Accolade titanium-molybdenum-zirconium-iron alloy femoral stems. All these cases were associated with adverse local tissue reactions requiring revision of the THA. RESULTS In our series, a conservative estimate of the incidence of failure was 4.7% (n = 636 total implanted) at 8.0 ± 1.4 years from the index procedure. Failures were associated with a high-offset 127° femoral stem neck angle and increased neck lengths; 43.3% (13 of 30) of the observed failures included implant sizes outside the voluntary recall (27.8% [5 of 18] of the GTF and 75.0% [8 of 12] of the taper corrosion cases). Serum cobalt and chromium levels were elevated (cobalt: 8.4 ± 7.0 μg/mL; chromium: 3.4 ± 3.3 μ/L; cobalt/chromium ratio: 3.7). The metal artifact reduction sequence magnetic resonance imaging demonstrated large cystic fluid collections typical with adverse local tissue reactions. During revision, a pseudotumor was observed in all cases. Pathology suggested a chronic inflammatory response. Impending GTF could be diagnosed based on aspiration of black synovial fluid and an oblique femoral head as compared with the neck taper on radiographs. CONCLUSION In our series of the recalled LFIT CoCr femoral head, the risk of impending GTF or head-neck taper corrosion should be considered as a potential diagnosis in a painful LFIT femoral head and Accolade titanium-molybdenum-zirconium-iron alloy THA with unknown etiology. Almost half of the failures we observed included sizes outside of the voluntary recall.
Collapse
Affiliation(s)
- Kenneth L. Urish
- The Bone & Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA 15212. Phone: 412.736.4261; Fax: 717.531.7583,Corresponding Author: The Bone & Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center; Department of Orthopaedic Surgery, College of Medicine, University of Pittsburgh, Pittsburgh, PA 15212.
| | - Brian R. Hamlin
- The Bone & Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA 15212. Phone: 412.736.4261; Fax: 717.531.7583
| | - Anton Y. Plakseychuk
- The Bone & Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA 15212. Phone: 412.736.4261; Fax: 717.531.7583
| | - Timothy J. Levison
- The Bone & Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA 15212. Phone: 412.736.4261; Fax: 717.531.7583
| | - Genymphas Higgs
- Implant Research Center, 3401 Market St., Suite 345, Philadelphia, PA. Phone: 215-901-4520
| | - Steven Kurtz
- Implant Research Center, 3401 Market St., Suite 345, Philadelphia, PA. Phone: 215-901-4520
| | - Anthony M. DiGioia
- The Bone & Joint Center, Magee Womens Hospital of the University of Pittsburgh Medical Center, Pittsburgh, PA 15212. Phone: 412.736.4261; Fax: 717.531.7583
| |
Collapse
|
44
|
Nodzo SR, Esposito CI, Potter HG, Ranawat CS, Wright TM, Padgett DE. MRI, Retrieval Analysis, and Histologic Evaluation of Adverse Local Tissue Reaction in Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty 2017; 32:1647-1653. [PMID: 28087160 DOI: 10.1016/j.arth.2016.11.046] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 11/15/2016] [Accepted: 11/28/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The severity and location of adverse local tissue reaction (ALTR) seen in metal-on-polyethylene total hip arthroplasty (THA) is not well described. METHODS We retrospectively reviewed the records of patients who underwent a revision THA using our biomechanics database. We included all patients who underwent revision surgery for the diagnosis of ALTR with THA implants that had modularity solely at the head-neck junction and excluded patients with implant modularity at sites other than the head-neck junction. Magnetic resonance imaging (MRI) was evaluated by a fellowship-trained radiologist who specializes in evaluating metal artifact reducing MRI sequences to quantify the ALTR lesions. Histology was evaluated for findings of ALTR using the Campbell score. RESULTS We identified 11 patients in the database. Eight patients had an MRI ALTR grade of severe and 7 did based on the histology score. The mean synovial volume was 218,658 mm3 (range 23,461-451,435 mm3) with a mean maximal synovial thickness of 15.3 mm (range 3-34.3 mm). A disruptive infiltration of the abductors due to pseudocapsule invasion was seen in 67% of the patients with 3 not having abductor involvement. Mean preoperative cobalt and chromium levels were 5.4 ppb (range 1-12.3 ppb) and 1.1 ppb (range 0.6-2.4 ppb), respectively. CONCLUSION Patients with ALTR from head-neck junction corrosion in metal-on-polyethylene THA may present with large pseudotumors that have previously been under appreciated. Mean preoperative serum cobalt and chromium ion levels remained relatively low, and MRI was an effective way to characterize the size and location of these lesions.
Collapse
Affiliation(s)
- Scott R Nodzo
- Department of Orthopaedics, Hospital for Special Surgery, New York, New York
| | | | - Hollis G Potter
- Department of Radiology, Hospital for Special Surgery, New York, New York
| | | | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Douglas E Padgett
- Department of Orthopaedics, Hospital for Special Surgery, New York, New York
| |
Collapse
|
45
|
Xia Z, Ricciardi BF, Liu Z, von Ruhland C, Ward M, Lord A, Hughes L, Goldring SR, Purdue E, Murray D, Perino G. Nano-analyses of wear particles from metal-on-metal and non-metal-on-metal dual modular neck hip arthroplasty. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2017; 13:1205-1217. [DOI: 10.1016/j.nano.2016.11.003] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Revised: 10/30/2016] [Accepted: 11/17/2016] [Indexed: 01/13/2023]
|