1
|
Yu ZL, Wu ZY, Liu XC, Ji CX, Wang X, Fu QY, Chen G, Wu M, Hong SL, Jia J. Predictive Analysis in Oral Cancer Immunotherapy: Profiling Dual PD-L1-Positive Extracellular Vesicle Subtypes with Step-Wedge Microfluidic Chips. Anal Chem 2024; 96:14980-14988. [PMID: 39235216 DOI: 10.1021/acs.analchem.4c03101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/06/2024]
Abstract
PD-L1-positive extracellular vesicles (PD-L1+ EVs) play a pivotal role as predictive biomarkers in cancer immunotherapy. These vesicles, originating from immune cells (I-PD-L1+ EVs) and tumor cells (T-PD-L1+ EVs), hold distinct clinical predictive values, emphasizing the importance of deeply differentiating the PD-L1+ EV subtypes for effective liquid biopsy analyses. However, current methods such as ELISA lack the ability to differentiate their cellular sources. In this study, a novel step-wedge microfluidic chip that combines magnetic microsphere separation with single-layer fluorescence counting is developed. This chip integrates magnetic microspheres modified with anti-PD-L1 antibodies and fluorescent nanoparticles targeting EpCAM (tumor cell marker) or CD45 (immunocyte marker), enabling simultaneous quantification and sensitive analysis of PD-L1+ EV subpopulations in oral squamous cell carcinoma (OSCC) patients' saliva without background interference. Analysis results indicate reduced levels of I-PD-L1+ EVs in OSCC patients compared to those in healthy individuals, with varying levels of heterogeneous PD-L1+ EVs observed among different patient groups. During immunotherapy, responders exhibit decreased levels of total PD-L1+ EVs and T-PD-L1+ EVs, accompanied by reduced levels of I-PD-L1+ EVs. Conversely, nonresponders show increased levels of I-PD-L1+ EVs. Utilizing the step-wedge microfluidic chip allows for simultaneous detection of PD-L1+ EV subtypes, facilitating the precise prediction of oral cancer immunotherapy outcomes.
Collapse
Affiliation(s)
- Zi-Li Yu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
- Department of Oral and Maxillofacial Surgery, School and Hospital of Stomatology, Wuhan University, Wuhan 430079, China
| | - Zhou-Yang Wu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
| | - Xing-Chi Liu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
| | - Chang-Xin Ji
- College of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China
| | - Xuan Wang
- College of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China
| | - Qiu-Yun Fu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
| | - Gang Chen
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
- Department of Oral and Maxillofacial Surgery, School and Hospital of Stomatology, Wuhan University, Wuhan 430079, China
- TaiKang Center for Life and Medical Sciences, Wuhan University, Wuhan 430071, China
- Frontier Science Center for Immunology and Metabolism, Wuhan University, Wuhan 430071, China
| | - Min Wu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
| | - Shao-Li Hong
- College of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China
| | - Jun Jia
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
- Department of Oral and Maxillofacial Surgery, School and Hospital of Stomatology, Wuhan University, Wuhan 430079, China
| |
Collapse
|
2
|
Surappa S, Multani P, Parlatan U, Sinawang PD, Kaifi J, Akin D, Demirci U. Integrated "lab-on-a-chip" microfluidic systems for isolation, enrichment, and analysis of cancer biomarkers. LAB ON A CHIP 2023; 23:2942-2958. [PMID: 37314731 PMCID: PMC10834032 DOI: 10.1039/d2lc01076c] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The liquid biopsy has garnered considerable attention as a complementary clinical tool for the early detection, molecular characterization and monitoring of cancer over the past decade. In contrast to traditional solid biopsy techniques, liquid biopsy offers a less invasive and safer alternative for routine cancer screening. Recent advances in microfluidic technologies have enabled handling of liquid biopsy-derived biomarkers with high sensitivity, throughput, and convenience. The integration of these multi-functional microfluidic technologies into a 'lab-on-a-chip' offers a powerful solution for processing and analyzing samples on a single platform, thereby reducing the complexity, bio-analyte loss and cross-contamination associated with multiple handling and transfer steps in more conventional benchtop workflows. This review critically addresses recent developments in integrated microfluidic technologies for cancer detection, highlighting isolation, enrichment, and analysis strategies for three important sub-types of cancer biomarkers: circulating tumor cells, circulating tumor DNA and exosomes. We first discuss the unique characteristics and advantages of the various lab-on-a-chip technologies developed to operate on each biomarker subtype. This is then followed by a discussion on the challenges and opportunities in the field of integrated systems for cancer detection. Ultimately, integrated microfluidic platforms form the core of a new class of point-of-care diagnostic tools by virtue of their ease-of-operation, portability and high sensitivity. Widespread availability of such tools could potentially result in more frequent and convenient screening for early signs of cancer at clinical labs or primary care offices.
Collapse
Affiliation(s)
- Sushruta Surappa
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Lab, Department of Radiology, School of Medicine, Stanford University, Palo Alto, CA 94304, USA.
| | - Priyanka Multani
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Lab, Department of Radiology, School of Medicine, Stanford University, Palo Alto, CA 94304, USA.
| | - Ugur Parlatan
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Lab, Department of Radiology, School of Medicine, Stanford University, Palo Alto, CA 94304, USA.
| | - Prima Dewi Sinawang
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Lab, Department of Radiology, School of Medicine, Stanford University, Palo Alto, CA 94304, USA.
- Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
| | - Jussuf Kaifi
- Department of Surgery, School of Medicine, University of Missouri, Columbia, MO 65212, USA
- Harry S. Truman Memorial Veterans' Hospital, Columbia, MO 65201, USA
| | - Demir Akin
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Lab, Department of Radiology, School of Medicine, Stanford University, Palo Alto, CA 94304, USA.
- Center for Cancer Nanotechnology Excellence for Translational Diagnostics (CCNE-TD), School of Medicine, Stanford University, Stanford, CA 94305, USA
| | - Utkan Demirci
- Canary Center at Stanford for Cancer Early Detection, Bio-Acoustic MEMS in Medicine (BAMM) Lab, Department of Radiology, School of Medicine, Stanford University, Palo Alto, CA 94304, USA.
| |
Collapse
|
3
|
Qian Y, Gu Y, Deng J, Cai Z, Wang Y, Zhou R, Zhu D, Lu H, Wang Z. Combined SERS Microfluidic Chip with Gold Nanocone Array for Effective Early Lung Cancer Prognosis in Mice Model. Int J Nanomedicine 2023; 18:3429-3442. [PMID: 37383221 PMCID: PMC10295598 DOI: 10.2147/ijn.s411395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 06/19/2023] [Indexed: 06/30/2023] Open
Abstract
Introduction As the most common malignant tumor in the world, the prognosis of patients with advanced lung cancer remains poor even after treatment. There are many prognostic marker assays available, but there is still more room for the development of high-throughput and sensitive detection of circulating tumor DNA (ctDNA). Surface-enhanced Raman spectroscopy (SERS), a spectroscopic detection method that has received wide attention in recent years, can achieve exponential amplification of Raman signals by using different metallic nanomaterials. Integrating SERS with signal amplification strategy into the microfluidic chip and applying it to ctDNA detection is expected to be an effective tool for the prognosis of lung cancer treatment effect in the future. Methods To construct a high-throughput SERS microfluidic chip integrated with enzyme-assisted signal amplification (EASA) and catalytic hairpin self-assembly (CHA) signal amplification strategies, using hpDNA-functionalized Au nanocone arrays (AuNCAs) as capture substrates and cisplatin-treated lung cancer mice to simulate the detection environment for sensitive detection of ctDNA in serum of lung cancer patients after treatment. Results The SERS microfluidic chip constructed by this scheme, with two reaction zones, can simultaneously and sensitively detect the concentrations of four prognostic ctDNAs in the serum of three lung cancer patients with a limit of detection (LOD) as low as the aM level. The results of the ELISA assay are consistent with this scheme, and its accuracy is guaranteed. Conclusion This high-throughput SERS microfluidic chip has high sensitivity and specificity in the detection of ctDNA. This could be a potential tool for prognostic assessment of lung cancer treatment efficacy in future clinical applications.
Collapse
Affiliation(s)
- Yayun Qian
- Department of Pathology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, People’s Republic of China
| | - Yuexing Gu
- Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, People’s Republic of China
| | - Jialin Deng
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People’s Republic of China
| | - Zhaoying Cai
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People’s Republic of China
| | - Yang Wang
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People’s Republic of China
| | - Ruoyu Zhou
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People’s Republic of China
| | - Dongxu Zhu
- Jiangsu Key Laboratory of Integrated Traditional Chinese and Western Medicine for Prevention and Treatment of Senile Diseases, Yangzhou University, Yangzhou, People’s Republic of China
| | - Hongmei Lu
- Department of Pathology, Yangzhou Maternal and Child Health Hospital, Yangzhou, People’s Republic of China
| | - Zheng Wang
- Department of Pathology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, People’s Republic of China
| |
Collapse
|
4
|
UÇAR A, ALI HAJOOL Z, GHORBANPOOR H, DİDARİAN R, DOĞAN GÜZEL F. Effect of microfluidic channel integration onto gold microelectrode on its redox electrochemistry. Turk J Chem 2022; 47:232-241. [PMID: 37720855 PMCID: PMC10504004 DOI: 10.55730/1300-0527.3532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 02/20/2023] [Accepted: 12/07/2022] [Indexed: 02/25/2023] Open
Abstract
Microfluidic systems have attracted significant interest in recent years as they are extensively employed in lab-on-chip and organ-on-chip research. Their combination with electrochemical platforms offers many advantages, promising a high potential for sensing applications, still the microfluidic-channel integration onto electrodes might induce challenges related to changes in signal-to-noise ratios and mass transport conditions. In this study, we investigated the effect of microfluidic channel integration in redox behavior of thermally deposited gold thin film microelectrodes by voltammetric (CV and SWV) electrochemical measurements. Using different dimensions of PDMS microfluidic channels (i.e. widths of 50, 100, 250, and 500 μm) and a constant electrode dimension (200 μm), we analyzed the relationship between altered electroactive area and electrochemical response against target redox molecules. The increases in electroactive area which were determined by the microfluidic channel sizes were in well-correlation with the obtained CV and SWV redox currents as expected. There was no significant decrease in signal-to-noise ratio in microchannel-integrated electrodes. AFM and SEM characterization demonstrated that thermally deposited thin film electrodes had significantly lower (approximately 25 fold) surface roughness in comparison to commercial screen-printed electrodes. Additionally, we have observed a clear microelectrode-to-macroelectrode transition, from hemispherical to linear (planar) diffusion in other terms, with the increasing channel size.
Collapse
Affiliation(s)
- Ahmet UÇAR
- Department of Energy Systems Engineering, Faculty of Engineering and Natural Sciences, Ankara Yildirim Beyazit University, Ankara,
Turkey
| | - Zahraa ALI HAJOOL
- Department of Metallurgical and Materials Engineering, Faculty of Engineering and Natural Sciences, Ankara Yildirim Beyazit University, Ankara,
Turkey
| | - Hamed GHORBANPOOR
- Department of Biomedical Engineering, Faculty of Engineering and Architecture, Eskisehir Osmangazi University, Eskisehir,
Turkey
| | - Reza DİDARİAN
- Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Ankara Yildirim Beyazit University, Ankara,
Turkey
| | - Fatma DOĞAN GÜZEL
- Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Ankara Yildirim Beyazit University, Ankara,
Turkey
- Department of Mechanical Engineering, Faculty of Engineering and Natural Sciences, Ankara Yildirim Beyazit University, Ankara,
Turkey
| |
Collapse
|
5
|
Li C, He W, Wang N, Xi Z, Deng R, Liu X, Kang R, Xie L, Liu X. Application of Microfluidics in Detection of Circulating Tumor Cells. Front Bioeng Biotechnol 2022; 10:907232. [PMID: 35646880 PMCID: PMC9133555 DOI: 10.3389/fbioe.2022.907232] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 04/11/2022] [Indexed: 12/22/2022] Open
Abstract
Tumor metastasis is one of the main causes of cancer incidence and death worldwide. In the process of tumor metastasis, the isolation and analysis of circulating tumor cells (CTCs) plays a crucial role in the early diagnosis and prognosis of cancer patients. Due to the rarity and inherent heterogeneity of CTCs, there is an urgent need for reliable CTCs separation and detection methods in order to obtain valuable information on tumor metastasis and progression from CTCs. Microfluidic technology is increasingly used in various studies of CTCs separation, identification and characterization because of its unique advantages, such as low cost, simple operation, less reagent consumption, miniaturization of the system, rapid detection and accurate control. This paper reviews the research progress of microfluidic technology in CTCs separation and detection in recent years, as well as the potential clinical application of CTCs, looks forward to the application prospect of microfluidic technology in the treatment of tumor metastasis, and briefly discusses the development prospect of microfluidic biosensor.
Collapse
Affiliation(s)
- Can Li
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
| | - Wei He
- Department of Clinical Medical Engineering, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Nan Wang
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
| | - Zhipeng Xi
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
| | - Rongrong Deng
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
| | - Xiyu Liu
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
| | - Ran Kang
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
- Department of Orthopedics, Nanjing Lishui Hospital of Traditional Chinese Medicine, Nanjing, China
| | - Lin Xie
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
| | - Xin Liu
- Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, School of Artificial Intelligence and Information Technology, Nanjing University of Chinese Medicine, Nanjing, China
| |
Collapse
|
6
|
Shi J, Zhao C, Shen M, Chen Z, Liu J, Zhang S, Zhang Z. Combination of microfluidic chips and biosensing for the enrichment of circulating tumor cells. Biosens Bioelectron 2022; 202:114025. [DOI: 10.1016/j.bios.2022.114025] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 01/12/2022] [Accepted: 01/18/2022] [Indexed: 12/26/2022]
|
7
|
CAO R, ZHANG M, YU H, QIN J. [Recent advances in isolation and detection of circulating tumor cells with a microfluidic system]. Se Pu 2022; 40:213-223. [PMID: 35243831 PMCID: PMC9404083 DOI: 10.3724/sp.j.1123.2021.07009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Indexed: 11/25/2022] Open
Abstract
The isolation and analysis of circulating tumor cells (CTCs) is an important issue in tumor research. CTCs in peripheral blood, which are important biomarkers of liquid biopsy, are closely related to the occurrence of cancer and are used to monitor the effect of treatment on cancer patients. However, the number of CTCs in the blood samples of cancer patients is very low, usually being present at only 0-10 CTCs/mL. Therefore, prior to the detection of CTCs, it is important to preprocess clinical blood samples for efficient separation and enrichment. With the advantages of low sample consumption, high separation efficiency, ease of automation and integration, microfluidic chips can be a suitable platform for the isolation of CTCs. In the last few years, CTC separation and detection using microfluidic chips have developed rapidly, and a variety of detection methods have been developed. According to the technical principle used, microfluidics for CTC separation can be divided into biological property-based methods and physical property-based methods. The biological property-based methods mainly depend on the interaction between the antigen and antibody, or the specific binding of the aptamer and target. These methods have high selectivity but low efficiency and recovery rates. Physical separation is based on the physical properties of CTCs such as their size, density, and dielectric properties. For example, CTCs can be blocked or captured by the microstructure in the channels of microfluidic chips, sorted by external physical fields (acoustic, electrical, magnetic), or screened by micro-scale hydrodynamics. Physical property-based methods generally have a higher flux but lower separation purity. However, the advantages of biological property-based methods and physical property-based methods can be integrated to provide microfluidic chips having better separation performance. In addition to the direct positive enrichment of CTCs, a negative enrichment strategy can also be adopted. The influence of direct screening on the activity of CTCs can be avoided by selectively removing white blood cells. In this paper, recent advances in microfluidics utilized in the isolation of CTCs, including physical and immune methods and positive and negative enrichment, are reviewed. We summarized the technical principles, detection methods, and research progress in CTC separation and detection using microfluidic chips. Developing trends in microfluidics for CTC separation and analysis are also discussed.
Collapse
|
8
|
Tang M, Chen J, Lei J, Ai Z, Liu F, Hong SL, Liu K. Precise and convenient size barcode on microfluidic chip for multiplex biomarker detection. Analyst 2021; 146:5892-5897. [PMID: 34494037 DOI: 10.1039/d1an01265g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The existing multiplex biomarker detection methods are limited by the high demand for coding material and expensive detection equipment. This paper proposes a convenient and precise coding method based on a wedge-shaped microfluidic chip, which can be further applied in multiplex biomarker detection. The proposed microfluidic chip has a microchannel with continuously varying height, which can naturally separate and code microparticles of different sizes. Our data indicate that this method can be applied to code more than 5 or 7 kinds of microparticles, even when their size discrepancies are smaller than 1 μm. Based on these, multiplex biomarker detection can be implemented by using microparticles of different sizes, hence each kind of microparticle that coats one kind of antibody represents the species of targets. This method is simple and easy to operate, with no clogging or sophisticated coding design, showing its significant potential in the area of point-of-care tests (POCT).
Collapse
Affiliation(s)
- Man Tang
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China. .,Hubei Engineering and Technology Research Centre for Functional Fibre Fabrication and Testing, Wuhan Textile University, Wuhan 430200, People's Republic of China.,Hubei Province Engineering Research Centre for Intelligent Micro-nano Medical Equipment and Key Technologies, Wuhan 30200, People's Republic of China
| | - Jinyao Chen
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China.
| | - Jia Lei
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China.
| | - Zhao Ai
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China. .,Hubei Engineering and Technology Research Centre for Functional Fibre Fabrication and Testing, Wuhan Textile University, Wuhan 430200, People's Republic of China.,Hubei Province Engineering Research Centre for Intelligent Micro-nano Medical Equipment and Key Technologies, Wuhan 30200, People's Republic of China
| | - Feng Liu
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China. .,Hubei Engineering and Technology Research Centre for Functional Fibre Fabrication and Testing, Wuhan Textile University, Wuhan 430200, People's Republic of China.,Hubei Province Engineering Research Centre for Intelligent Micro-nano Medical Equipment and Key Technologies, Wuhan 30200, People's Republic of China
| | - Shao-Li Hong
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China. .,Hubei Engineering and Technology Research Centre for Functional Fibre Fabrication and Testing, Wuhan Textile University, Wuhan 430200, People's Republic of China.,Hubei Province Engineering Research Centre for Intelligent Micro-nano Medical Equipment and Key Technologies, Wuhan 30200, People's Republic of China
| | - Kan Liu
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, People's Republic of China. .,Hubei Engineering and Technology Research Centre for Functional Fibre Fabrication and Testing, Wuhan Textile University, Wuhan 430200, People's Republic of China.,Hubei Province Engineering Research Centre for Intelligent Micro-nano Medical Equipment and Key Technologies, Wuhan 30200, People's Republic of China
| |
Collapse
|
9
|
EGFR mutation detection of lung circulating tumor cells using a multifunctional microfluidic chip. Talanta 2021; 225:122057. [PMID: 33592778 DOI: 10.1016/j.talanta.2020.122057] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 12/21/2020] [Accepted: 12/23/2020] [Indexed: 11/20/2022]
Abstract
Microfluidics has become a reliable platform for circulating tumor cells (CTCs) detection because of its high integration, small size, low consumption of reagents and rapid response. Here, we developed a multifunctional microfluidic device consists of three parts, including CTCs capture area, single-layer membrane valves area, and microcavity nucleic acid detection and analysis region based on digital polymerase chain reaction (dPCR), allowing CTCs capture, lysis, and genetic characterization to be performed on a single chip. The CTCs capture chip is coupled to the nucleic acid detection chip via a control valve. CTCs were firstly trapped in the CTC capture area, and then lysed using proteinase K to release nucleic acids. Subsequently CTCs lysate was transferred into nucleic acid detection area consisting of 12800 micro-cavity chambers for nucleic acids detection. To evaluate the performance of this chip, this study detected EGFR-L858R mutation in lung cancer cell lines H1975 and A549 cells, as well as leukocytes from normal donors. The results showed that positive signals were only observed in H1975 cells, and the detected value had a high linear relationship with the expected value (R2 = 0.9897). In conclusion, this multi-functional microfluidic chip that integrates CTCs capture, lysis and nucleic acid detection can successfully detect gene mutations in CTCs, providing reference for tumor-targeted drugs and precise diagnosis and treatment.
Collapse
|