1
|
Cersosimo A, Salerno N, Sabatino J, Scatteia A, Bisaccia G, De Rosa S, Dellegrottaglie S, Bucciarelli-Ducci C, Torella D, Leo I. Underlying mechanisms and cardioprotective effects of SGLT2i and GLP-1Ra: insights from cardiovascular magnetic resonance. Cardiovasc Diabetol 2024; 23:94. [PMID: 38468245 PMCID: PMC10926589 DOI: 10.1186/s12933-024-02181-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 02/26/2024] [Indexed: 03/13/2024] Open
Abstract
Originally designed as anti-hyperglycemic drugs, Glucagon-Like Peptide-1 receptor agonists (GLP-1Ra) and Sodium-glucose cotransporter-2 inhibitors (SGLT2i) have demonstrated protective cardiovascular effects, with significant impact on cardiovascular morbidity and mortality. Despite several mechanisms have been proposed, the exact pathophysiology behind these effects is not yet fully understood. Cardiovascular imaging is key for the evaluation of diabetic patients, with an established role from the identification of early subclinical changes to long-term follow up and prognostic assessment. Among the different imaging modalities, CMR may have a key-role being the gold standard for volumes and function assessment and having the unique ability to provide tissue characterization. Novel techniques are also implementing the possibility to evaluate cardiac metabolism through CMR and thereby further increasing the potential role of the modality in this context. Aim of this paper is to provide a comprehensive review of changes in CMR parameters and novel CMR techniques applied in both pre-clinical and clinical studies evaluating the effects of SGLT2i and GLP-1Ra, and their potential role in better understanding the underlying CV mechanisms of these drugs.
Collapse
Affiliation(s)
- Angelica Cersosimo
- Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy
| | - Nadia Salerno
- Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy
| | - Jolanda Sabatino
- Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy
| | - Alessandra Scatteia
- Advanced Cardiovascular Imaging Unit, Ospedale Medico-Chirurgico Accreditato Villa dei Fiori, Naples, Italy
| | - Giandomenico Bisaccia
- Department of Neuroscience, Imaging and Clinical Sciences, Institute for Advanced Biomedical Technologies "G. d'Annunzio", University of Chieti-Pescara, Chieti, Italy
| | - Salvatore De Rosa
- Department of Medical and Surgical Sciences, Magna Graecia University, Catanzaro, Italy
| | - Santo Dellegrottaglie
- Advanced Cardiovascular Imaging Unit, Ospedale Medico-Chirurgico Accreditato Villa dei Fiori, Naples, Italy
| | - Chiara Bucciarelli-Ducci
- CMR Unit, Royal Brompton and Harefield Hospitals, Guy's and St Thomas' NHS Foundation Trust, London, UK
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, Kings College London, London, UK
| | - Daniele Torella
- Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy.
| | - Isabella Leo
- Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy.
| |
Collapse
|
2
|
Campbell-Washburn AE, Varghese J, Nayak KS, Ramasawmy R, Simonetti OP. Cardiac MRI at Low Field Strengths. J Magn Reson Imaging 2024; 59:412-430. [PMID: 37530545 PMCID: PMC10834858 DOI: 10.1002/jmri.28890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 08/03/2023] Open
Abstract
Cardiac MR imaging is well established for assessment of cardiovascular structure and function, myocardial scar, quantitative flow, parametric mapping, and myocardial perfusion. Despite the clear evidence supporting the use of cardiac MRI for a wide range of indications, it is underutilized clinically. Recent developments in low-field MRI technology, including modern data acquisition and image reconstruction methods, are enabling high-quality low-field imaging that may improve the cost-benefit ratio for cardiac MRI. Studies to-date confirm that low-field MRI offers high measurement concordance and consistent interpretation with clinical imaging for several routine sequences. Moreover, low-field MRI may enable specific new clinical opportunities for cardiac imaging such as imaging near metal implants, MRI-guided interventions, combined cardiopulmonary assessment, and imaging of patients with severe obesity. In this review, we discuss the recent progress in low-field cardiac MRI with a focus on technical developments and early clinical validation studies. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Adrienne E Campbell-Washburn
- Cardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD USA
| | - Juliet Varghese
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
- Alfred Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD USA
| | - Orlando P Simonetti
- Division of Cardiovascular Medicine, Department of Internal Medicine, College of Medicine, The Ohio State University, Columbus, OH, USA
- Department of Radiology, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
3
|
Božić‐Iven M, Rapacchi S, Tao Q, Pierce I, Thornton G, Nitsche C, Treibel TA, Schad LR, Weingärtner S. Improved reproducibility for myocardial ASL: Impact of physiological and acquisition parameters. Magn Reson Med 2024; 91:118-132. [PMID: 37667643 PMCID: PMC10962577 DOI: 10.1002/mrm.29834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Revised: 07/26/2023] [Accepted: 07/31/2023] [Indexed: 09/06/2023]
Abstract
PURPOSE To investigate and mitigate the influence of physiological and acquisition-related parameters on myocardial blood flow (MBF) measurements obtained with myocardial Arterial Spin Labeling (myoASL). METHODS A Flow-sensitive Alternating Inversion Recovery (FAIR) myoASL sequence with bSSFP and spoiled GRE (spGRE) readout is investigated for MBF quantification. Bloch-equation simulations and phantom experiments were performed to evaluate how variations in acquisition flip angle (FA), acquisition matrix size (AMS), heart rate (HR) and bloodT 1 $$ {\mathrm{T}}_1 $$ relaxation time (T 1 , B $$ {\mathrm{T}}_{1,B} $$ ) affect quantification of myoASL-MBF. In vivo myoASL-images were acquired in nine healthy subjects. A corrected MBF quantification approach was proposed based on subject-specificT 1 , B $$ {\mathrm{T}}_{1,B} $$ values and, for spGRE imaging, subtracting an additional saturation-prepared baseline from the original baseline signal. RESULTS Simulated and phantom experiments showed a strong dependence on AMS and FA (R 2 $$ {R}^2 $$ >0.73), which was eliminated in simulations and alleviated in phantom experiments using the proposed saturation-baseline correction in spGRE. Only a very mild HR dependence (R 2 $$ {R}^2 $$ >0.59) was observed which was reduced when calculating MBF with individualT 1 , B $$ {\mathrm{T}}_{1,B} $$ . For corrected spGRE, in vivo mean global spGRE-MBF ranged from 0.54 to 2.59 mL/g/min and was in agreement with previously reported values. Compared to uncorrected spGRE, the intra-subject variability within a measurement (0.60 mL/g/min), between measurements (0.45 mL/g/min), as well as the inter-subject variability (1.29 mL/g/min) were improved by up to 40% and were comparable with conventional bSSFP. CONCLUSION Our results show that physiological and acquisition-related factors can lead to spurious changes in myoASL-MBF if not accounted for. Using individualT 1 , B $$ {\mathrm{T}}_{1,B} $$ and a saturation-baseline can reduce these variations in spGRE and improve reproducibility of FAIR-myoASL against acquisition parameters.
Collapse
Affiliation(s)
- Maša Božić‐Iven
- Medical Faculty MannheimHeidelberg UniversityMannheimGermany
- Department of Imaging PhysicsDelft University of TechnologyDelftThe Netherlands
| | | | - Qian Tao
- Department of Imaging PhysicsDelft University of TechnologyDelftThe Netherlands
| | - Iain Pierce
- Barts Heart CentreSt Bartholomew's HospitalLondonUK
| | - George Thornton
- Barts Heart CentreSt Bartholomew's HospitalLondonUK
- Institute of Cardiovascular ScienceUniversity College LondonLondonUK
| | - Christian Nitsche
- Barts Heart CentreSt Bartholomew's HospitalLondonUK
- Institute of Cardiovascular ScienceUniversity College LondonLondonUK
- Division of CardiologyMedical University of ViennaViennaAustria
| | - Thomas A. Treibel
- Barts Heart CentreSt Bartholomew's HospitalLondonUK
- Institute of Cardiovascular ScienceUniversity College LondonLondonUK
| | - Lothar R. Schad
- Medical Faculty MannheimHeidelberg UniversityMannheimGermany
| | | |
Collapse
|
4
|
Taso M, Aramendía-Vidaurreta V, Englund EK, Francis S, Franklin S, Madhuranthakam AJ, Martirosian P, Nayak KS, Qin Q, Shao X, Thomas DL, Zun Z, Fernández-Seara MA. Update on state-of-the-art for arterial spin labeling (ASL) human perfusion imaging outside of the brain. Magn Reson Med 2023; 89:1754-1776. [PMID: 36747380 DOI: 10.1002/mrm.29609] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 01/09/2023] [Accepted: 01/16/2023] [Indexed: 02/08/2023]
Abstract
This review article provides an overview of developments for arterial spin labeling (ASL) perfusion imaging in the body (i.e., outside of the brain). It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group. In this review, we focus on specific challenges and developments tailored for ASL in a variety of body locations. After presenting common challenges, organ-specific reviews of challenges and developments are presented, including kidneys, lungs, heart (myocardium), placenta, eye (retina), liver, pancreas, and muscle, which are regions that have seen the most developments outside of the brain. Summaries and recommendations of acquisition parameters (when appropriate) are provided for each organ. We then explore the possibilities for wider adoption of body ASL based on large standardization efforts, as well as the potential opportunities based on recent advances in high/low-field systems and machine-learning. This review seeks to provide an overview of the current state-of-the-art of ASL for applications in the body, highlighting ongoing challenges and solutions that aim to enable more widespread use of the technique in clinical practice.
Collapse
Affiliation(s)
- Manuel Taso
- Division of MRI Research, Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA
| | | | - Erin K Englund
- Department of Radiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Susan Francis
- Sir Peter Mansfield Imaging Center, University of Nottingham, Nottingham, UK
| | - Suzanne Franklin
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
- Center for Image Sciences, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Ananth J Madhuranthakam
- Department of Radiology, Advanced Imaging Research Center, and Biomedical Engineering, UT Southwestern Medical Center, Dallas, Texas, USA
| | - Petros Martirosian
- Section on Experimental Radiology, Department of Radiology, University Hospital of Tuebingen, Tuebingen, Germany
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Qin Qin
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, USA
| | - Xingfeng Shao
- Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - David L Thomas
- Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Zungho Zun
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA
| | | |
Collapse
|
5
|
Reiss S, Wäscher K, Caglar Özen A, Lottner T, Timo Heidt, von Zur Mühlen C, Bock M. Quantifying myocardial perfusion during MR-guided interventions without exogenous contrast agents: intra-arterial spin labeling. Z Med Phys 2023:S0939-3889(23)00002-8. [PMID: 36717310 DOI: 10.1016/j.zemedi.2023.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/05/2023] [Accepted: 01/05/2023] [Indexed: 01/30/2023]
Abstract
PURPOSE To test intra-arterial spin labeling (iASL) using active guiding catheters for myocardial perfusion measurements during magnetic resonance (MR)-guided interventions in a pig study. METHODS In this work, a single-loop radiofrequency (RF) coil at the tip of a 6F active coronary catheter was used as a transmit coil for local spin labeling. The transmit magnetic RF field (B1) of the coil and the labeling efficiency were determined, and iASL was tested in two pigs after the catheter was engaged in the aortic root, the ostium of the left coronary artery (LCA) under MR-guidance. The iASL effect was assessed by the signal difference between spin-labeling On and control (spin-labeling OFF) images, and in a cross-correlation between ON/Off states of spin-labeling a binary labeling paradigm. In addition, quantitative myocardial perfusion was calculated from the iASL experiments. RESULTS The maximum B1 in the vicinity of the catheter coil was 2.1 µT. A strong local labeling effect with a labeling efficiency of 0.45 was achieved with iASL both in vitro and in vivo. In both pigs, the proximal myocardial segments supplied by the LCA showed significant labelling effect up to distances of 60 mm from the aortic root with a relative signal difference of (3.14 ± 2.89)% in the first and (3.50 ± 1.25)% in the second animal. The mean correlation coefficients were R = 0.63 ± 0.22 and 0.42 ± 0.16, respectively. The corresponding computed myocardial perfusion values in this region of the myocardium were similar to those obtained with contrast perfusion methods ((1.2 ± 1.1) mL/min/g and (0.8 ± 0.6) mL/min/g). CONCLUSION The proposed iASL method demonstrates the feasibility of selective myocardial perfusion measurements during MR-guided coronary interventions, which with further technical improvements may provide an alternative to exogenous contrast-based perfusion. Due to the invasive nature of the iASL method, it can potentially be used in concert with MRI-guided coronary angioplasty.
Collapse
Affiliation(s)
- Simon Reiss
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Kevin Wäscher
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ali Caglar Özen
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Thomas Lottner
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Timo Heidt
- Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Constantin von Zur Mühlen
- Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
6
|
Henningsson M, Carlhäll CJ, Ebbers T, Kihlberg J. Non-contrast myocardial perfusion in rest and exercise stress using systolic flow-sensitive alternating inversion recovery. MAGMA (NEW YORK, N.Y.) 2022; 35:711-718. [PMID: 34958438 PMCID: PMC9463284 DOI: 10.1007/s10334-021-00992-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 11/19/2021] [Accepted: 12/13/2021] [Indexed: 06/14/2023]
Abstract
OBJECTIVE To evaluate systolic flow-sensitive alternating inversion recovery (FAIR) during rest and exercise stress using 2RR (two cardiac cycles) or 1RR intervals between inversion pulse and imaging. MATERIALS AND METHODS 1RR and 2RR FAIR was implemented on a 3T scanner. Ten healthy subjects were scanned during rest and stress. Stress was performed using an in-bore ergometer. Heart rate, mean myocardial blood flow (MBF) and temporal signal-to-noise ratio (TSNR) were compared using paired t tests. RESULTS Mean heart rate during stress was higher than rest for 1RR FAIR (85.8 ± 13.7 bpm vs 63.3 ± 11.1 bpm; p < 0.01) and 2RR FAIR (83.8 ± 14.2 bpm vs 63.1 ± 10.6 bpm; p < 0.01). Mean stress MBF was higher than rest for 1RR FAIR (2.97 ± 0.76 ml/g/min vs 1.43 ± 0.6 ml/g/min; p < 0.01) and 2RR FAIR (2.8 ± 0.96 ml/g/min vs 1.22 ± 0.59 ml/g/min; p < 0.01). Resting mean MBF was higher for 1RR FAIR than 2RR FAIR (p < 0.05), but not during stress. TSNR was lower for stress compared to rest for 1RR FAIR (4.52 ± 2.54 vs 10.12 ± 3.69; p < 0.01) and 2RR FAIR (7.36 ± 3.78 vs 12.41 ± 5.12; p < 0.01). 2RR FAIR TSNR was higher than 1RR FAIR for rest (p < 0.05) and stress (p < 0.001). DISCUSSION We have demonstrated feasibility of systolic FAIR in rest and exercise stress. 2RR delay systolic FAIR enables non-contrast perfusion assessment during stress with relatively high TSNR.
Collapse
Affiliation(s)
- Markus Henningsson
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Tino Ebbers
- Unit of Cardiovascular Sciences, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Johan Kihlberg
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Department of Radiology, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
7
|
Hatakeyama N, Kobayashi S. Development and practical evaluation of a saturation effect learning simulator for inflow magnetic resonance angiography. Radiol Phys Technol 2022; 15:311-322. [PMID: 36002782 DOI: 10.1007/s12194-022-00671-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 08/05/2022] [Accepted: 08/06/2022] [Indexed: 11/25/2022]
Abstract
The quality of visualization in inflow magnetic resonance angiography (MRA) depends highly on the excitation state of the longitudinal magnetization obtained using specified imaging parameters. In addition, signal intensity changes controlled by the preparation pulse-such as inversion recovery (IR) and saturation recovery (SR)-can potentially be used as quantitative physiological values. Although having practitioners understand these relationships both qualitatively and quantitatively is important, handling clinical equipment in practical learning or experiments involves limited opportunities. The simulator corresponds to a three-dimensional spoiled gradient echo sequence and allows users to freely input multiple virtual excitation effects in space and time. The purpose of this study was to quantitatively evaluate the agreement between the measured MRAs obtained in flow phantom tests and virtual MRAs simulated under similar conditions. We imaged two vascular flow phantoms on a 3.0 T MR system using three-dimensional (3D) time-of-flight (TOF) MRA and 3D inversion recovery tissue signal suppression (IR-suppression) MRA protocols. We evaluated quantitative values for consistency between the measured and virtual MRAs images with matched spatial resolution. Then we assessed the coincidence by reformatting maximum-intensity projection images with 1 mm isotropic pixels, with it ranging from 89.6 to 92.0% and 89.1 to 92.9% for TOF MRA and IR-suppression MRA, respectively. These results may be useful as a reference index for the theoretical study of MRA images by practitioners, for complementary validation by phantom testing, or for the development of MRI-related simulators.
Collapse
Affiliation(s)
- Norishige Hatakeyama
- Nagano Chuo Hospital, 1570 Nishi-Tsuruga, Nagano, 380-0814, Japan.
- Graduate School of Medicine, Science and Technology, Shinshu University, Matsumoto, Japan.
| | - Shunichi Kobayashi
- Graduate School of Medicine, Science and Technology, Shinshu University, Matsumoto, Japan
| |
Collapse
|
8
|
Abstract
Major advances in biomedical imaging have occurred over the last 2 decades and now allow many physiological, cellular, and molecular processes to be imaged noninvasively in small animal models of cardiovascular disease. Many of these techniques can be also used in humans, providing pathophysiological context and helping to define the clinical relevance of the model. Ultrasound remains the most widely used approach, and dedicated high-frequency systems can obtain extremely detailed images in mice. Likewise, dedicated small animal tomographic systems have been developed for magnetic resonance, positron emission tomography, fluorescence imaging, and computed tomography in mice. In this article, we review the use of ultrasound and positron emission tomography in small animal models, as well as emerging contrast mechanisms in magnetic resonance such as diffusion tensor imaging, hyperpolarized magnetic resonance, chemical exchange saturation transfer imaging, magnetic resonance elastography and strain, arterial spin labeling, and molecular imaging.
Collapse
Affiliation(s)
- David E Sosnovik
- Cardiology Division, Cardiovascular Research Center (D.E.S.), Massachusetts General Hospital and Harvard Medical School, Boston.,A.A. Martinos Center for Biomedical Imaging (D.E.S.), Massachusetts General Hospital and Harvard Medical School, Boston.,Harvard-MIT Program in Health Sciences and Technology, Harvard Medical School and Massachusetts Institute of Technology, Cambridge (D.E.S.)
| | - Marielle Scherrer-Crosbie
- Cardiology Division, Hospital of the University of Pennsylvania and Perelman School of Medicine, Philadelphia (M.S.-C)
| |
Collapse
|
9
|
Ismail TF, Strugnell W, Coletti C, Božić-Iven M, Weingärtner S, Hammernik K, Correia T, Küstner T. Cardiac MR: From Theory to Practice. Front Cardiovasc Med 2022; 9:826283. [PMID: 35310962 PMCID: PMC8927633 DOI: 10.3389/fcvm.2022.826283] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 01/17/2022] [Indexed: 01/10/2023] Open
Abstract
Cardiovascular disease (CVD) is the leading single cause of morbidity and mortality, causing over 17. 9 million deaths worldwide per year with associated costs of over $800 billion. Improving prevention, diagnosis, and treatment of CVD is therefore a global priority. Cardiovascular magnetic resonance (CMR) has emerged as a clinically important technique for the assessment of cardiovascular anatomy, function, perfusion, and viability. However, diversity and complexity of imaging, reconstruction and analysis methods pose some limitations to the widespread use of CMR. Especially in view of recent developments in the field of machine learning that provide novel solutions to address existing problems, it is necessary to bridge the gap between the clinical and scientific communities. This review covers five essential aspects of CMR to provide a comprehensive overview ranging from CVDs to CMR pulse sequence design, acquisition protocols, motion handling, image reconstruction and quantitative analysis of the obtained data. (1) The basic MR physics of CMR is introduced. Basic pulse sequence building blocks that are commonly used in CMR imaging are presented. Sequences containing these building blocks are formed for parametric mapping and functional imaging techniques. Commonly perceived artifacts and potential countermeasures are discussed for these methods. (2) CMR methods for identifying CVDs are illustrated. Basic anatomy and functional processes are described to understand the cardiac pathologies and how they can be captured by CMR imaging. (3) The planning and conduct of a complete CMR exam which is targeted for the respective pathology is shown. Building blocks are illustrated to create an efficient and patient-centered workflow. Further strategies to cope with challenging patients are discussed. (4) Imaging acceleration and reconstruction techniques are presented that enable acquisition of spatial, temporal, and parametric dynamics of the cardiac cycle. The handling of respiratory and cardiac motion strategies as well as their integration into the reconstruction processes is showcased. (5) Recent advances on deep learning-based reconstructions for this purpose are summarized. Furthermore, an overview of novel deep learning image segmentation and analysis methods is provided with a focus on automatic, fast and reliable extraction of biomarkers and parameters of clinical relevance.
Collapse
Affiliation(s)
- Tevfik F. Ismail
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Cardiology Department, Guy's and St Thomas' Hospital, London, United Kingdom
| | - Wendy Strugnell
- Queensland X-Ray, Mater Hospital Brisbane, Brisbane, QLD, Australia
| | - Chiara Coletti
- Magnetic Resonance Systems Lab, Delft University of Technology, Delft, Netherlands
| | - Maša Božić-Iven
- Magnetic Resonance Systems Lab, Delft University of Technology, Delft, Netherlands
- Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany
| | | | - Kerstin Hammernik
- Lab for AI in Medicine, Technical University of Munich, Munich, Germany
- Department of Computing, Imperial College London, London, United Kingdom
| | - Teresa Correia
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Centre of Marine Sciences, Faro, Portugal
| | - Thomas Küstner
- Medical Image and Data Analysis (MIDAS.lab), Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Tübingen, Germany
| |
Collapse
|
10
|
Aramendía-Vidaurreta V, Gordaliza PM, Vidorreta M, Echeverría-Chasco R, Bastarrika G, Muñoz-Barrutia A, Fernández-Seara MA. Reduction of motion effects in myocardial arterial spin labeling. Magn Reson Med 2021; 87:1261-1275. [PMID: 34644410 DOI: 10.1002/mrm.29038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 09/09/2021] [Accepted: 09/20/2021] [Indexed: 11/09/2022]
Abstract
PURPOSE To evaluate the accuracy and reproducibility of myocardial blood flow measurements obtained under different breathing strategies and motion correction techniques with arterial spin labeling. METHODS A prospective cardiac arterial spin labeling study was performed in 12 volunteers at 3 Tesla. Perfusion images were acquired twice under breath-hold, synchronized-breathing, and free-breathing. Motion detection based on the temporal intensity variation of a myocardial voxel, as well as image registration based on pairwise and groupwise approaches, were applied and evaluated in synthetic and in vivo data. A region of interest was drawn over the mean perfusion-weighted image for quantification. Original breath-hold datasets, analyzed with individual regions of interest for each perfusion-weighted image, were considered as reference values. RESULTS Perfusion measurements in the reference breath-hold datasets were in line with those reported in literature. In original datasets, prior to motion correction, myocardial blood flow quantification was significantly overestimated due to contamination of the myocardial perfusion with the high intensity signal of blood pool. These effects were minimized with motion detection or registration. Synthetic data showed that accuracy of the perfusion measurements was higher with the use of registration, in particular after the pairwise approach, which probed to be more robust to motion. CONCLUSION Satisfactory results were obtained for the free-breathing strategy after pairwise registration, with higher accuracy and robustness (in synthetic datasets) and higher intrasession reproducibility together with lower myocardial blood flow variability across subjects (in in vivo datasets). Breath-hold and synchronized-breathing after motion correction provided similar results, but these breathing strategies can be difficult to perform by patients.
Collapse
Affiliation(s)
- Verónica Aramendía-Vidaurreta
- Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain.,IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain
| | - Pedro M Gordaliza
- Department of Bioengineering and Aerospace Engineering, Universidad Carlos III de Madrid, Madrid, Spain.,Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain
| | | | - Rebeca Echeverría-Chasco
- Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain.,IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain
| | - Gorka Bastarrika
- Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain.,IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain
| | - Arrate Muñoz-Barrutia
- Department of Bioengineering and Aerospace Engineering, Universidad Carlos III de Madrid, Madrid, Spain.,Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain
| | - María A Fernández-Seara
- Department of Radiology, Clínica Universidad de Navarra, Pamplona, Spain.,IdiSNA, Instituto de Investigación Sanitaria de Navarra, Pamplona, Spain
| |
Collapse
|
11
|
Ku MC, Kober F, Lai YC, Pohlmann A, Qadri F, Bader M, Carrier L, Niendorf T. Cardiovascular magnetic resonance detects microvascular dysfunction in a mouse model of hypertrophic cardiomyopathy. J Cardiovasc Magn Reson 2021; 23:63. [PMID: 34053450 PMCID: PMC8166121 DOI: 10.1186/s12968-021-00754-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 04/06/2021] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Hypertrophic cardiomyopathy (HCM) related myocardial vascular remodelling may lead to the reduction of myocardial blood supply and a subsequent progressive loss of cardiac function. This process has been difficult to observe and thus their connection remains unclear. Here we used non-invasive myocardial blood flow sensitive CMR to show an impairment of resting myocardial perfusion in a mouse model of naturally occurring HCM. METHODS We used a mouse model (DBA/2 J; D2 mouse strain) that spontaneously carries variants in the two most susceptible HCM genes-Mybpc3 and Myh7 and bears the key features of human HCM. The C57BL/6 J (B6) was used as a reference strain. Mice with either B6 or D2 backgrounds (male: n = 4, female: n = 4) underwent cine-CMR for functional assessment at 9.4 T. Left ventricular (LV) wall thickness was measured in end diastolic phase by cine-CMR. Quantitative myocardial perfusion maps (male: n = 5, female: n = 5 in each group) were acquired from arterial spin labelling (cine ASL-CMR) at rest. Myocardial perfusion values were measured by delineating different regions of interest based on the LV segmentation model in the mid ventricle of the LV myocardium. Directly after the CMR, the mouse hearts were removed for histological assessments to confirm the incidence of myocardial interstitial fibrosis (n = 8 in each group) and small vessel remodelling such as vessel density (n = 6 in each group) and perivascular fibrosis (n = 8 in each group). RESULTS LV hypertrophy was more pronounced in D2 than in B6 mice (male: D2 LV wall thickness = 1.3 ± 0.1 mm vs B6 LV wall thickness = 1.0 ± 0.0 mm, p < 0.001; female: D2 LV wall thickness = 1.0 ± 0.1 mm vs B6 LV wall thickness = 0.8 ± 0.1 mm, p < 0.01). The resting global myocardial perfusion (myocardial blood flow; MBF) was lower in D2 than in B6 mice (end-diastole: D2 MBFglobal = 7.5 ± 0.6 vs B6 MBFglobal = 9.3 ± 1.6 ml/g/min, p < 0.05; end-systole: D2 MBFglobal = 6.6 ± 0.8 vs B6 MBFglobal = 8.2 ± 2.6 ml/g/min, p < 0.01). This myocardial microvascular dysfunction was observed and associated with a reduction in regional MBF, mainly in the interventricular septal and inferior areas of the myocardium. Immunofluorescence revealed a lower number of vessel densities in D2 than in B6 (D2 capillary = 31.0 ± 3.8% vs B6 capillary = 40.7 ± 4.6%, p < 0.05). Myocardial collagen volume fraction (CVF) was significantly higher in D2 LV versus B6 LV mice (D2 CVF = 3.7 ± 1.4% vs B6 CVF = 1.7 ± 0.7%, p < 0.01). Furthermore, a higher ratio of perivascular fibrosis (PFR) was found in D2 than in B6 mice (D2 PFR = 2.3 ± 1.0%, B6 PFR = 0.8 ± 0.4%, p < 0.01). CONCLUSIONS Our work describes an imaging marker using cine ASL-CMR with a potential to monitor vascular and myocardial remodelling in HCM.
Collapse
Affiliation(s)
- Min-Chi Ku
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany.
- DZHK (German Centre for Cardiovascular Research), Partner site Berlin, Berlin, Germany.
| | - Frank Kober
- Centre de Résonance Magnétique Biologique et Médicale (CRMBM), Aix-Marseille University, CNRS, Marseille, France
| | - Yi-Ching Lai
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany
| | - Fatimunnisa Qadri
- Molecular Biology of Peptide Hormones, Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
| | - Michael Bader
- DZHK (German Centre for Cardiovascular Research), Partner site Berlin, Berlin, Germany
- Molecular Biology of Peptide Hormones, Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Berlin, Germany
| | - Lucie Carrier
- Department of Experimental Pharmacology and Toxicology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner site Hamburg/Kiel/Lübeck, Berlin, Germany
| | - Thoralf Niendorf
- Berlin Ultrahigh Field Facility (B.U.F.F.), Max Delbrück Center for Molecular Medicine in the Helmholtz Association (MDC), Robert-Rössle Strasse 10, 13125, Berlin, Germany
- DZHK (German Centre for Cardiovascular Research), Partner site Berlin, Berlin, Germany
- Experimental and Clinical Research Center (ECRC), A Joint Cooperation between the Charité Medical Faculty and the Max-Delbrück Center for Molecular Medicine, Berlin, Germany
| |
Collapse
|
12
|
Sirajuddin A, Mirmomen SM, Kligerman SJ, Groves DW, Burke AP, Kureshi F, White CS, Arai AE. Ischemic Heart Disease: Noninvasive Imaging Techniques and Findings. Radiographics 2021; 41:990-1021. [PMID: 34019437 PMCID: PMC8262179 DOI: 10.1148/rg.2021200125] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Ischemic heart disease is a leading cause of death worldwide and comprises a large proportion of annual health care expenditure. Management of ischemic heart disease is now best guided by the physiologic significance of coronary artery stenosis. Invasive coronary angiography is the standard for diagnosing coronary artery stenosis. However, it is expensive and has risks including vascular access site complications and contrast material–induced nephropathy. Invasive coronary angiography requires fractional flow reserve (FFR) measurement to determine the physiologic significance of a coronary artery stenosis. Multiple noninvasive cardiac imaging modalities can also anatomically delineate or functionally assess for significant coronary artery stenosis, as well as detect the presence of myocardial infarction (MI). While coronary CT angiography can help assess the degree of anatomic stenosis, its inability to assess the physiologic significance of lesions limits its specificity. Physiologic significance of coronary artery stenosis can be determined by cardiac MR vasodilator or dobutamine stress imaging, CT stress perfusion imaging, FFR CT, PET myocardial perfusion imaging (MPI), SPECT MPI, and stress echocardiography. Clinically unrecognized MI, another clear indicator of physiologically significant coronary artery disease, is relatively common and is best evaluated with cardiac MRI. The authors illustrate the spectrum of imaging findings of ischemic heart disease (coronary artery disease, myocardial ischemia, and MI); highlight the advantages and disadvantages of the various noninvasive imaging methods used to assess ischemic heart disease, as illustrated by recent clinical trials; and summarize current indications and contraindications for noninvasive imaging techniques for detection of ischemic heart disease. Online supplemental material is available for this article. Published under a CC BY 4.0 license.
Collapse
Affiliation(s)
- Arlene Sirajuddin
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| | - S Mojdeh Mirmomen
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| | - Seth J Kligerman
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| | - Daniel W Groves
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| | - Allen P Burke
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| | - Faraz Kureshi
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| | - Charles S White
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| | - Andrew E Arai
- From the Cardiovascular and Pulmonary Branch, National Heart Lung and Blood Institute, National Institutes of Health, 10 Center Dr, Building 10, Room B1D416, Bethesda, MD 20814 (A.S., S.M.M., A.E.A.); Department of Radiology, University of California San Diego, San Diego, Calif (S.J.K.); Departments of Medicine and Radiology, Divisions of Cardiology and Cardiothoracic Imaging, University of Colorado Anschutz Medical Campus, Aurora, Colo (D.W.G.); Department of Pathology (A.P.B.) and Department of Radiology and Nuclear Medicine (C.S.W.), School of Medicine, University of Maryland, Baltimore, Md; and St David's Healthcare and Austin Heart, Austin, Tex (F.K.)
| |
Collapse
|
13
|
Emrich T, Halfmann M, Schoepf UJ, Kreitner KF. CMR for myocardial characterization in ischemic heart disease: state-of-the-art and future developments. Eur Radiol Exp 2021; 5:14. [PMID: 33763757 PMCID: PMC7990980 DOI: 10.1186/s41747-021-00208-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 01/22/2021] [Indexed: 01/25/2023] Open
Abstract
Ischemic heart disease and its sequelae are one of the major contributors to morbidity and mortality worldwide. Over the last decades, technological developments have strengthened the role of noninvasive imaging for detection, risk stratification, and management of patients with ischemic heart disease. Cardiac magnetic resonance (CMR) imaging incorporates both functional and morphological characterization of the heart to determine presence, acuteness, and severity of ischemic heart disease by evaluating myocardial wall motion and function, the presence and extent of myocardial edema, ischemia, and scarring. Currently established clinical protocols have already demonstrated their diagnostic and prognostic value. Nevertheless, there are emerging imaging technologies that provide additional information based on advanced quantification of imaging biomarkers and improved diagnostic accuracy, therefore potentially allowing reduction or avoidance of contrast and/or stressor agents. The aim of this review is to summarize the current state of the art of CMR imaging for ischemic heart disease and to provide insights into promising future developments.
Collapse
Affiliation(s)
- Tilman Emrich
- Department of Diagnostic and Interventional Radiology, University Medical Center, Mainz; Langenbeckstraße 1, 55131, Mainz, Germany. .,German Center for Cardiovascular Research (DZHK), Partner Site Rhine Main, Mainz, Langenbeckstraße 1, 55131, Mainz, Germany. .,Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, 29425, USA.
| | - Moritz Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center, Mainz; Langenbeckstraße 1, 55131, Mainz, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Rhine Main, Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - U Joseph Schoepf
- Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, 29425, USA
| | - Karl-Friedrich Kreitner
- Department of Diagnostic and Interventional Radiology, University Medical Center, Mainz; Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
14
|
Henningsson M, Carlhäll C, Kihlberg J. Myocardial arterial spin labeling in systole and diastole using flow-sensitive alternating inversion recovery with parallel imaging and compressed sensing. NMR IN BIOMEDICINE 2021; 34:e4436. [PMID: 33150707 PMCID: PMC7816237 DOI: 10.1002/nbm.4436] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 10/08/2020] [Accepted: 10/08/2020] [Indexed: 06/11/2023]
Abstract
Quantitative myocardial perfusion can be achieved without contrast agents using flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling. However, FAIR has an intrinsically low sensitivity, which may be improved by mitigating the effects of physiological noise or by increasing the area of artifact-free myocardium. The aim of this study was to investigate if systolic FAIR may increase the amount of analyzable myocardium compared with diastolic FAIR and its effect on physiological noise. Furthermore, we compare parallel imaging acceleration with a factor of 2 with compressed sensing acceleration with a factor of 3 for systolic FAIR. Twelve healthy subjects were scanned during rest on a 3 T scanner using diastolic FAIR with parallel imaging factor 2 (FAIR-PI2D ), systolic FAIR with the same acceleration (FAIR-PI2S ) and systolic FAIR with compressed sensing factor 3 (FAIR-CS3S ). The number of analyzable pixels in the myocardium, temporal signal-to-noise ratio (TSNR) and mean myocardial blood flow (MBF) were calculated for all methods. The number of analyzable pixels using FAIR-CS3S (663 ± 55) and FAIR-PI2S (671 ± 58) was significantly higher than for FAIR-PI2D (507 ± 82; P = .001 for both), while there was no significant difference between FAIR-PI2S and FAIR-CS3S . The mean TSNR of the midventricular slice for FAIR-PI2D was 11.4 ± 3.9, similar to that of FAIR-CS3S, which was 11.0 ± 3.3, both considerably higher than for FAIR-PI2S, which was 8.4 ± 3.1 (P < .05 for both). Mean MBF was similar for all three methods. The use of compressed sensing accelerated systolic FAIR benefits from an increased number of analyzable myocardial pixels compared with diastolic FAIR without suffering from a TSNR penalty, unlike systolic FAIR with parallel imaging acceleration.
Collapse
Affiliation(s)
- Markus Henningsson
- Unit for Cardiovascular Sciences, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
- Center for Medical Image Science and Visualization (CMIV)Linköping UniversityLinköpingSweden
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Carl‐Johan Carlhäll
- Unit for Cardiovascular Sciences, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
- Center for Medical Image Science and Visualization (CMIV)Linköping UniversityLinköpingSweden
- Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
| | - Johan Kihlberg
- Center for Medical Image Science and Visualization (CMIV)Linköping UniversityLinköpingSweden
- Department of Radiology, Department of Health, Medicine and Caring SciencesLinköping UniversityLinköpingSweden
| |
Collapse
|
15
|
MnDPDP: Contrast Agent for Imaging and Protection of Viable Tissue. CONTRAST MEDIA & MOLECULAR IMAGING 2020; 2020:3262835. [PMID: 32994754 PMCID: PMC7501573 DOI: 10.1155/2020/3262835] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 05/12/2020] [Indexed: 01/22/2023]
Abstract
The semistable chelate manganese (Mn) dipyridoxyl diphosphate (MnDPDP, mangafodipir), previously used as an intravenous (i.v.) contrast agent (Teslascan™, GE Healthcare) for Mn-ion-enhanced MRI (MEMRI), should be reappraised for clinical use but now as a diagnostic drug with cytoprotective properties. Approved for imaging of the liver and pancreas, MnDPDP enhances contrast also in other targets such as the heart, kidney, glandular tissue, and potentially retina and brain. Transmetallation releases paramagnetic Mn2+ for cellular uptake in competition with calcium (Ca2+), and intracellular (IC) macromolecular Mn2+ adducts lower myocardial T1 to midway between native values and values obtained with gadolinium (Gd3+). What is essential is that T1 mapping and, to a lesser degree, T1 weighted imaging enable quantification of viability at a cellular or even molecular level. IC Mn2+ retention for hours provides delayed imaging as another advantage. Examples in humans include quantitative imaging of cardiomyocyte remodeling and of Ca2+ channel activity, capabilities beyond the scope of Gd3+ based or native MRI. In addition, MnDPDP and the metabolite Mn dipyridoxyl diethyl-diamine (MnPLED) act as catalytic antioxidants enabling prevention and treatment of oxidative stress caused by tissue injury and inflammation. Tested applications in humans include protection of normal cells during chemotherapy of cancer and, potentially, of ischemic tissues during reperfusion. Theragnostic use combining therapy with delayed imaging remains to be explored. This review updates MnDPDP and its clinical potential with emphasis on the working mode of an exquisite chelate in the diagnosis of heart disease and in the treatment of oxidative stress.
Collapse
|
16
|
Dilsizian V, Gewirtz H, Marwick TH, Kwong RY, Raggi P, Al-Mallah MH, Herzog CA. Cardiac Imaging for Coronary Heart Disease Risk Stratification in Chronic Kidney Disease. JACC Cardiovasc Imaging 2020; 14:669-682. [PMID: 32828780 DOI: 10.1016/j.jcmg.2020.05.035] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 04/22/2020] [Accepted: 05/13/2020] [Indexed: 02/07/2023]
Abstract
Chronic kidney disease (CKD), defined as dysfunction of the glomerular filtration apparatus, is an independent risk factor for the development of coronary artery disease (CAD). Patients with CKD are at a substantially higher risk of cardiovascular mortality compared with the age- and sex-adjusted general population with normal kidney function. The risk of CAD and mortality in patients with CKD is correlated with the degree of renal dysfunction including presence of microalbuminuria. A greater cardiovascular risk, albeit lower than for patients receiving dialysis, persists even after kidney transplantation. Congestive heart failure, commonly caused by CAD, also accounts for a significant portion of the cardiovascular-related events observed in CKD. The optimal strategy for the evaluation of CAD in patients with CKD, particularly before renal transplantation, remains a topic of contention spanning over several decades. Although the evaluation of coexisting cardiac disease in patients with CKD is desirable, severe renal dysfunction limits the use of radiographic and magnetic resonance contrast agents due to concerns regarding contrast-induced nephropathy and nephrogenic systemic sclerosis, respectively. In addition, many patients with CKD have extensive and premature (often medial) calcification disproportionate to the severity of obstructive CAD, thereby limiting the diagnostic value of computed tomography angiography. As such, echocardiography, non-contrast-enhanced magnetic resonance, nuclear myocardial perfusion, and metabolic imaging offer a variety of approaches to assess obstructive CAD and cardiomyopathy of advanced CKD without the need for nephrotoxic contrast agents.
Collapse
Affiliation(s)
- Vasken Dilsizian
- Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, Maryland, USA.
| | - Henry Gewirtz
- Department of Medicine (Cardiology Division), Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Thomas H Marwick
- Baker Heart and Diabetes Institute, Melbourne, Victoria, Australia
| | - Raymond Y Kwong
- Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | - Paolo Raggi
- Mazankowski Alberta Heart Institute, University of Alberta, Edmonton, Alberta, Canada
| | - Mouaz H Al-Mallah
- Houston Methodist DeBakey Heart & Vascular Center, Houston, Texas, USA
| | - Charles A Herzog
- Department of Medicine (Cardiology Division) and Chronic Disease Research Group, Hennepin Healthcare, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
17
|
Lee NG, Javed A, Jao TR, Nayak KS. Numerical approximation to the general kinetic model for ASL quantification. Magn Reson Med 2020; 84:2846-2857. [PMID: 32367574 DOI: 10.1002/mrm.28304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 03/19/2020] [Accepted: 04/08/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE To develop a numerical approximation to the general kinetic model for arterial spin labeling (ASL) quantification that will enable greater flexibility in ASL acquisition methods. THEORY The Bloch-McConnell equations are extended to include the effects of single-compartment inflow and outflow on both the transverse and longitudinal magnetization. These can be solved using an extension of Jaynes' matrix formalism with piecewise constant approximation of incoming labeled arterial flow and a clearance operator for outgoing venous flow. METHODS The proposed numerical approximation is compared with the general kinetic model using simulations of pulsed labeling and pseudo-continuous labeling and a broad range of transit time and bolus duration for tissue blood flow of 0.6 mL/g/min. Accuracy of the approximation is studied as a function of the timestep using Monte-Carlo simulations. Three additional scenarios are demonstrated: (1) steady-pulsed ASL, (2) MR fingerprinting ASL, and (3) balanced SSFP and spoiled gradient-echo sequences. RESULTS The proposed approximation was found to be arbitrarily accurate for pulsed labeling and pseudo-continuous labeling. The pulsed labeling/pseudo-continuous labeling approximation error compared with the general kinetic model was less than 0.002% (<0.002%) and less than 0.05% (<0.05%) for timesteps of 3 ms and 35 ms, respectively. The proposed approximation matched well with customized signal expressions of steady-pulsed ASL and MR fingerprinting ASL. The simulations of simultaneous modeling of flow, T2 , and magnetization transfer showed an increase in steady-state balanced SSFP and spoiled gradient signals. CONCLUSION We demonstrate a numerical approximation of the "Bloch-McConnell flow" equations that enables arbitrarily accurate modeling of pulsed ASL and pseudo-continuous labeling signals comparable to the general kinetic model. This enables increased flexibility in the experiment design for quantitative ASL.
Collapse
Affiliation(s)
- Nam G Lee
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA
| | - Ahsan Javed
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Terrence R Jao
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
18
|
Javed A, Nayak KS. Single-shot EPI for ASL-CMR. Magn Reson Med 2020; 84:738-750. [PMID: 32060949 DOI: 10.1002/mrm.28165] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 11/23/2019] [Accepted: 12/15/2019] [Indexed: 01/08/2023]
Abstract
PURPOSE To evaluate single-shot echo planar imaging (SS-EPI), as an alternative to snapshot balanced steady state free precession (bSSFP) imaging, for arterial-spin-labeled cardiac MR (ASL-CMR). This study presents a practical implementation SS-EPI tailored to the needs of ASL-CMR at 3T and demonstrates sequential multi-slice ASL with no increase in scan time. METHODS Reduced field of view SS-EPI was performed using a 2DRF pulse. A spin-echo was used with crushers optimized to maximize blood suppression and minimize myocardial signal loss, based on experiments in 4 healthy volunteers. SS-EPI was evaluated against the widely used bSSFP reference method in single-slice ASL-CMR in 4 healthy volunteers, during both systole and diastole. Sequential multi-slice ASL-CMR with SS-EPI was demonstrated during diastole (3 slices: basal, mid, and apical short-axis) and during systole (2 slices: mid and apical short-axis), in 3 volunteers. RESULTS Global myocardial perfusion for diastolic SS-EPI (1.66 ± 0.73 mL/g/min) and systolic SS-EPI (1.50 ± 0.36 mL/g/min) were found to be statistically equivalent (2 one-sided test with a difference of 0.4 mL/g/min) to diastolic bSSFP (duration of 1 cardiac cycle, 1.60 ± 0.80 mL/g/min) with P-values of 0.022 and 0.031, respectively. Global myocardial perfusion for sequential multi-slice experiments was 1.64 ± 0.47, 1.34 ± 0.29, and 1.88 ± 0.58 for basal, mid, and apical SAX slices during diastole and was 1.61 ± 0.35, and 1.66 ± 0.49 for mid and apical slice during systole. These values are comparable to published ASL-CMR and positron emission tomography studies. CONCLUSION SS-EPI is a promising alternative to bSSFP imaging for ASL-CMR and can potentially improve the spatial coverage of ASL-CMR by 3-fold during diastole and 2-fold during systole, without increasing scan time.
Collapse
Affiliation(s)
- Ahsan Javed
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California
| |
Collapse
|
19
|
Javed A, Yoon A, Cen S, Nayak KS, Garg P. Feasibility of coronary endothelial function assessment using arterial spin labeled CMR. NMR IN BIOMEDICINE 2020; 33:e4183. [PMID: 31799707 PMCID: PMC6980265 DOI: 10.1002/nbm.4183] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2019] [Revised: 07/25/2019] [Accepted: 07/26/2019] [Indexed: 06/10/2023]
Abstract
Coronary endothelial dysfunction (CED) is an independent predictor of cardiovascular disease, but its assessment has been limited to invasive coronary angiography. Myocardial perfusion imaging using arterial spin labeled (ASL) cardiac magnetic resonance (CMR) may be an effective non-invasive alternative for detection of CED. Thirty-four patients were recruited: 10 healthy volunteers, 13 at high-risk for coronary artery disease (CAD), and 11 with established CAD. ASL-CMR was performed continuously in a single mid-short axis slice during rest, stress, and recovery. Stress was induced with sustained isometric handgrip exercise, an endothelial dependent stressor. Myocardial perfusion (MP) during rest, peak stress, and recovery were calculated and compared. After excluding subjects unable to complete the protocol or who exhibited poor data quality, 6 healthy, 10 high-risk, and 7 CAD patients were included in the analysis. Average MP (ml/g/min) was 1.31 ± 1.23, 1.61 ± 1.12, and 1.40 ± 0.97 at rest, and 1.64 ± 1.49, 2.31 ± 1.61, and 2.84 ± 1.77 during stress, for the CAD, high-risk and healthy group, respectively. The average MP response (MPstress - MPrest , ml/g/min) was 0.32 ± 1.93, 0.69 ± 1.34, and 1.44 ± 1.46 for CAD, high-risk and healthy group, respectively. MP during handgrip stress was significantly lower for both the CAD (p = 0.0005) and high-risk groups (p = 0.05) compared to the healthy volunteers. In only the healthy subjects, MP was significantly higher in stress compared to rest (p = 0.0002). Participants with CAD had significantly lower MP response compared to healthy volunteers, as detected by ASL-CMR. These findings support the feasibility of ASL-CMR for non-invasive assessment of CED.
Collapse
Affiliation(s)
- Ahsan Javed
- Ming Hsieh Department of Electrical and computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Andrew Yoon
- Division of Cardiovascular Medicine, Department of Medicine, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Steven Cen
- Department of Neurology and Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Parveen Garg
- Division of Cardiovascular Medicine, Department of Medicine, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
20
|
Do HP, Guo Y, Yoon AJ, Nayak KS. Accuracy, uncertainty, and adaptability of automatic myocardial ASL segmentation using deep CNN. Magn Reson Med 2019; 83:1863-1874. [PMID: 31729078 DOI: 10.1002/mrm.28043] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 09/23/2019] [Accepted: 09/24/2019] [Indexed: 01/25/2023]
Abstract
PURPOSE To apply deep convolution neural network to the segmentation task in myocardial arterial spin labeled perfusion imaging and to develop methods that measure uncertainty and that adapt the convolution neural network model to a specific false-positive versus false-negative tradeoff. METHODS The Monte Carlo dropout U-Net was trained on data from 22 subjects and tested on data from 6 heart transplant recipients. Manual segmentation and regional myocardial blood flow were available for comparison. We consider 2 global uncertainty measures, named "Dice uncertainty" and "Monte Carlo dropout uncertainty," which were calculated with and without the use of manual segmentation, respectively. Tversky loss function with a hyperparameter β was used to adapt the model to a specific false-positive versus false-negative tradeoff. RESULTS The Monte Carlo dropout U-Net achieved a Dice coefficient of 0.91 ± 0.04 on the test set. Myocardial blood flow measured using automatic segmentations was highly correlated to that measured using the manual segmentation (R2 = 0.96). Dice uncertainty and Monte Carlo dropout uncertainty were in good agreement (R2 = 0.64). As β increased, the false-positive rate systematically decreased and false-negative rate systematically increased. CONCLUSION We demonstrate the feasibility of deep convolution neural network for automatic segmentation of myocardial arterial spin labeling, with good accuracy. We also introduce 2 simple methods for assessing model uncertainty. Finally, we demonstrate the ability to adapt the convolution neural network model to a specific false-positive versus false-negative tradeoff. These findings are directly relevant to automatic segmentation in quantitative cardiac MRI and are broadly applicable to automatic segmentation problems in diagnostic imaging.
Collapse
Affiliation(s)
- Hung P Do
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California
| | - Yi Guo
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California
| | - Andrew J Yoon
- Long Beach Memorial Medical Center, University of California Irvine, Irvine, California
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California
| |
Collapse
|
21
|
Kwiatkowski G, Kozerke S. Extended quantitative dynamic contrast-enhanced cardiac perfusion imaging in mice using accelerated data acquisition and spatially distributed, two-compartment exchange modeling. NMR IN BIOMEDICINE 2019; 32:e4123. [PMID: 31209939 DOI: 10.1002/nbm.4123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 04/25/2019] [Accepted: 05/04/2019] [Indexed: 05/28/2023]
Abstract
The objective of the present work was to improve data acquisition and quantification of dynamic contrast-enhanced perfusion imaging in the in vivo murine heart. Four-fold undersampled data were acquired in 14 mice and reconstructed using k-t SPARSE. A two-compartment exchange model was employed to provide additional characterization of myocardial tissue based on compartment volumes and the permeability surface area product. The feasibility of the proposed method was tested using compartment-based analysis of contrast-enhanced perfusion data acquired with intravascular and extracellular contrast agents. A significantly different permeability surface area product was measured for the intravascular versus extracellular contrast agent (0.13-0.15 ml/g/min vs 0.86-0.88 ml/g/min). The reduced extravasation also resulted in significantly smaller interstitial volumes of the intravascular versus extracellular agent (9.8-11% vs 45-47%). No difference was found for myocardial blood flow (6.5-7.2 ml/g/min vs 6.0-7.0 ml/g/min). The results presented here show that two-compartment exchange modeling in the in vivo murine heart is feasible and gives access to tissue parameters beyond myocardial blood flow.
Collapse
Affiliation(s)
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH, Zurich, Switzerland
| |
Collapse
|
22
|
Jerosch-Herold M, Slomka P. Myocardial Blood Flow Quantification With Dynamic Contrast-Enhanced Computed Tomography. Circ Cardiovasc Imaging 2019; 12:e009431. [DOI: 10.1161/circimaging.119.009431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
| | - Piotr Slomka
- Artificial Intelligence in Medicine Program, Cedars-Sinai Medical Center, Los Angeles, CA (P.S.)
| |
Collapse
|
23
|
Aramendía-Vidaurreta V, García-Osés A, Vidorreta M, Bastarrika G, Fernández-Seara MA. Optimal repetition time for free breathing myocardial arterial spin labeling. NMR IN BIOMEDICINE 2019; 32:e4077. [PMID: 30811728 DOI: 10.1002/nbm.4077] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 12/21/2018] [Accepted: 01/15/2019] [Indexed: 06/09/2023]
Abstract
The aim of this study was to improve the scan efficiency of ASL in the myocardium. Free breathing FAIR-ASL scans with different TRs were compared, while keeping the acquisition time constant. Scans were named by the trigger pulse that started each acquisition: every two (TP1), four (TP2) and six (TP3) cardiac cycles. TP2 offered the best alternative with a coefficient of variation of 17.15% intrasession and 36.85% intersession. Mean MBF increased by 0.22 ± 0.41 ml/g/min with mild stress.
Collapse
Affiliation(s)
| | | | | | - Gorka Bastarrika
- Radiology Department, Clínica Universidad de Navarra, Pamplona, Spain
| | | |
Collapse
|
24
|
Manning WJ. Journal of Cardiovascular Magnetic Resonance 2017. J Cardiovasc Magn Reson 2018; 20:89. [PMID: 30593280 PMCID: PMC6309095 DOI: 10.1186/s12968-018-0518-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 12/06/2018] [Indexed: 02/07/2023] Open
Abstract
There were 106 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2017, including 92 original research papers, 3 reviews, 9 technical notes, and 1 Position paper, 1 erratum and 1 correction. The volume was similar to 2016 despite an increase in manuscript submissions to 405 and thus reflects a slight decrease in the acceptance rate to 26.7%. The quality of the submissions continues to be high. The 2017 JCMR Impact Factor (which is published in June 2018) was minimally lower at 5.46 (vs. 5.71 for 2016; as published in June 2017), which is the second highest impact factor ever recorded for JCMR. The 2017 impact factor means that an average, each JCMR paper that were published in 2015 and 2016 was cited 5.46 times in 2017.In accordance with Open-Access publishing of Biomed Central, the JCMR articles are published on-line in continuus fashion and in the chronologic order of acceptance, with no collating of the articles into sections or special thematic issues. For this reason, over the years, the Editors have felt that it is useful to annually summarize the publications into broad areas of interest or theme, so that readers can view areas of interest in a single article in relation to each other and other contemporary JCMR articles. In this publication, the manuscripts are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought within the journal. In addition, I have elected to use this format to convey information regarding the editorial process to the readership.I hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your very best, high quality manuscripts to JCMR for consideration. I thank our very dedicated Associate Editors, Guest Editors, and Reviewers for their efforts to ensure that the review process occurs in a timely and responsible manner and that the JCMR continues to be recognized as the forefront journal of our field. And finally, I thank you for entrusting me with the editorship of the JCMR as I begin my 3rd year as your editor-in-chief. It has been a tremendous learning experience for me and the opportunity to review manuscripts that reflect the best in our field remains a great joy and highlight of my week!
Collapse
Affiliation(s)
- Warren J Manning
- Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA, 02215, USA.
| |
Collapse
|
25
|
Nery F, De Vita E, Clark CA, Gordon I, Thomas DL. Robust kidney perfusion mapping in pediatric chronic kidney disease using single-shot 3D-GRASE ASL with optimized retrospective motion correction. Magn Reson Med 2018; 81:2972-2984. [PMID: 30536817 DOI: 10.1002/mrm.27614] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 10/24/2018] [Accepted: 10/25/2018] [Indexed: 12/18/2022]
Abstract
PURPOSE To develop a robust renal arterial spin labeling (ASL) acquisition and processing strategy for mapping renal blood flow (RBF) in a pediatric cohort with severe kidney disease. METHODS A single-shot background-suppressed 3D gradient and spin-echo (GRASE) flow-sensitive alternating inversion recovery (FAIR) ASL acquisition method was used to perform 2 studies. First, an evaluation of the feasibility of single-shot 3D-GRASE and retrospective noise reduction methods was performed in healthy volunteers. Second, a pediatric cohort with severe chronic kidney disease underwent single-shot 3D-GRASE FAIR ASL and RBF was quantified following several retrospective motion correction pipelines, including image registration and threshold-free weighted averaging. The effect of motion correction on the fit errors of saturation recovery (SR) images (required for RBF quantification) and on the perfusion-weighted image (PWI) temporal signal-to-noise ratio (tSNR) was evaluated, as well as the intra- and inter-session repeatability of renal longitudinal relaxation time (T1 ) and RBF. RESULTS The mean cortical and/or functional renal parenchyma RBF in healthy volunteers and CKD patients was 295 ± 97 and 95 ± 47 mL/100 g/min, respectively. Motion-correction reduced image artefacts in both T1 and RBF maps, significantly reduced SR fit errors, significantly increased the PWI tSNR and improved the improved the repeatability of T1 and RBF in the pediatric patient cohort. CONCLUSION Single-shot 3D-GRASE ASL combined with retrospective motion correction enabled repeatable non-invasive RBF mapping in the first pediatric cohort with severe kidney disease undergoing ASL scans.
Collapse
Affiliation(s)
- Fabio Nery
- Developmental Imaging and Biophysics Section, University College London Great Ormond Street Institute of Child Health, London, United Kingdom
| | - Enrico De Vita
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King's College London, King's Health Partners, St Thomas' Hospital, London, United Kingdom
| | - Chris A Clark
- Developmental Imaging and Biophysics Section, University College London Great Ormond Street Institute of Child Health, London, United Kingdom
| | - Isky Gordon
- Developmental Imaging and Biophysics Section, University College London Great Ormond Street Institute of Child Health, London, United Kingdom
| | - David L Thomas
- Department of Brain Repair and Rehabilitation, University College London Queen Square Institute of Neurology, Queen Square, London, United Kingdom.,Leonard Wolfson Experimental Neurology Centre, University College London Queen Square Institute of Neurology, Queen Square, London, United Kingdom
| |
Collapse
|
26
|
Multi-phase 3D arterial spin labeling brain MRI in assessing cerebral blood perfusion and arterial transit times in children at 3T. Clin Imaging 2018; 53:210-220. [PMID: 30439588 DOI: 10.1016/j.clinimag.2018.11.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Revised: 10/10/2018] [Accepted: 11/02/2018] [Indexed: 12/18/2022]
Abstract
BACKGROUND 3D pseudocontinuous arterial spin labeling (pCASL) with a single post-labeling delay time is commonly used to measure cerebral blood flow (CBF). Multi-phase pCASL has been developed to simultaneously estimate CBF and arterial transit time (ATT). PURPOSE To evaluate the clinical feasibility of multi-phase 3D pCASL in pediatric patients, and to compare the estimation of ATT and CBF via linear weighted-delay and traditional non-linear iterative curve-fitting routines. MATERIAL & METHODS Forty patients (average age: 8.6 y, 5 d-22.4 y) referred for routine brain MRI underwent additional 5-7 min of pCASL scans at 3T using 5 PLDs between 300 and 2300 ms. Data were post-processed by two algorithms for estimating CBF and ATT. Average CBF and ATT values were computed for vascular territories including the anterior, middle and posterior cerebral arteries as well as regions based on the Alberta Stroke Program Early CT Score template. Pearson correlation coefficients and linear regression were used for statistical analysis. The clinical value of multi-phase CASL was evaluated by a neuroradiologist based on asymmetric CBF and ATT maps in patients. RESULTS All pCASL scans were successfully completed, generating diagnostic results. CBF computed from weighted-delay and curve-fitting methods agreed strongly, with Pearson correlation coefficients ranging from 0.97-0.99 across the measured regions (p < 0.05). Correlation coefficients for ATT ranged from 0.87-0.96 (p < 0.05). CBF and ATT maps were found to add valuable information to clinical diagnosis in 17 of 40 pediatric patients. CONCLUSION Our preliminary results demonstrate the feasibility and potential clinical utility of multi-phase pCASL for simultaneous CBF and ATT quantification in pediatric patients.
Collapse
|
27
|
Clinical utility of arterial spin labeling for preoperative grading of glioma. Biosci Rep 2018; 38:BSR20180507. [PMID: 29769414 PMCID: PMC6117615 DOI: 10.1042/bsr20180507] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Revised: 05/09/2018] [Accepted: 05/15/2018] [Indexed: 12/30/2022] Open
Abstract
There were obvious differences in biological behavior and prognosis between low- and high-grade gliomas, it is of great importance for clinicians to make a right judgement for preoperative grading. We conducted a comprehensive meta-analysis to evaluate the clinical utility of arterial spin labeling for preoperative grading. We searched the PubMed, Embase, China National Knowledge Infrastructure, and Weipu electronic databases for articles published through 10 November 2017 and used ‘arterial spin-labeling’ or ‘ASL perfusion, grading’ or ‘differentiation, glioma’ or ‘glial tumor, diagnostic test’ as the search terms. A manual search of relevant original and review articles was performed to identify additional studies. The meta-analysis included nine studies. No obvious heterogeneity was found in the data in a fixed-effect model. The pooled sensitivity and specificity were 90% (95% confidence interval (CI): 0.84–0.94) and 91% (95% CI: 0.83–0.96), respectively, and the pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 10.40 (95% CI: 2.21–20.77) and 0.11 (95% CI: 0.07–0.18). The diagnostic odds ratio (DOR) was 92.47 (95% CI: 39.61–215.92). The diagnostic score was 4.53 (95% CI: 3.68–5.38). The area under the curve (AUC) was 0.94 (95% CI: 0.91–0.96). Subgroup analyses did not change the pooled results. No publication bias was found (P=0.102). The normalized maximal tumor blood flow/normal white matter ratio obtained with the arterial spin labeling technique was relatively accurate for distinguishing high/low-grade glioma. As a non-invasive procedure with favorable repeatability, this index may be useful for clinical diagnostics.
Collapse
|
28
|
Do HP, Ramanan V, Qi X, Barry J, Wright GA, Ghugre NR, Nayak KS. Non-contrast assessment of microvascular integrity using arterial spin labeled cardiovascular magnetic resonance in a porcine model of acute myocardial infarction. J Cardiovasc Magn Reson 2018; 20:45. [PMID: 29961424 PMCID: PMC6027570 DOI: 10.1186/s12968-018-0468-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2017] [Accepted: 06/04/2018] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Following acute myocardial infarction (AMI), microvascular integrity and function may be compromised as a result of microvascular obstruction (MVO) and vasodilator dysfunction. It has been observed that both infarcted and remote myocardial territories may exhibit impaired myocardial blood flow (MBF) patterns associated with an abnormal vasodilator response. Arterial spin labeled (ASL) CMR is a novel non-contrast technique that can quantitatively measure MBF. This study investigates the feasibility of ASL-CMR to assess MVO and vasodilator response in swine. METHODS Thirty-one swine were included in this study. Resting ASL-CMR was performed on 24 healthy swine (baseline group). A subset of 13 swine from the baseline group underwent stress ASL-CMR to assess vasodilator response. Fifteen swine were subjected to a 90-min left anterior descending (LAD) coronary artery occlusion followed by reperfusion. Resting ASL-CMR was performed post-AMI at 1-2 days (N = 9, of which 6 were from the baseline group), 1-2 weeks (N = 8, of which 4 were from the day 1-2 group), and 4 weeks (N = 4, of which 2 were from the week 1-2 group). Resting first-pass CMR and late gadolinium enhancement (LGE) were performed post-AMI for reference. RESULTS At rest, regional MBF and physiological noise measured from ASL-CMR were 1.08 ± 0.62 and 0.15 ± 0.10 ml/g/min, respectively. Regional MBF increased to 1.47 ± 0.62 ml/g/min with dipyridamole vasodilation (P < 0.001). Significant reduction in MBF was found in the infarcted region 1-2 days, 1-2 weeks, and 4 weeks post-AMI compared to baseline (P < 0.03). This was consistent with perfusion deficit seen on first-pass CMR and with MVO seen on LGE. There were no significant differences between measured MBF in the remote regions pre and post-AMI (P > 0.60). CONCLUSIONS ASL-CMR can assess vasodilator response in healthy swine and detect significant reduction in regional MBF at rest following AMI. ASL-CMR is an alternative to gadolinium-based techniques for assessment of MVO and microvascular integrity within infarcted, as well as salvageable and remote myocardium. This has the potential to provide early indications of adverse remodeling processes post-ischemia.
Collapse
Affiliation(s)
- Hung P. Do
- Department of Physics and Astronomy, University of Southern California, 3740 McClintock Ave, EEB 400, Los Angeles, California 90089-2564 USA
| | - Venkat Ramanan
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON Canada
| | - Xiuling Qi
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON Canada
| | - Jennifer Barry
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON Canada
| | - Graham A. Wright
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON Canada
- Schulich Heart Research Program, Sunnybrook Health Sciences Centre, Toronto, ON Canada
| | - Nilesh R. Ghugre
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON Canada
- Schulich Heart Research Program, Sunnybrook Health Sciences Centre, Toronto, ON Canada
| | - Krishna S. Nayak
- Ming Hsieh Department of Electrical Engineering, University of Southern California, Los Angeles, CA USA
| |
Collapse
|
29
|
Wespi P, Steinhauser J, Kwiatkowski G, Kozerke S. Overestimation of cardiac lactate production caused by liver metabolism of hyperpolarized [1- 13 C]pyruvate. Magn Reson Med 2018; 80:1882-1890. [PMID: 29607535 DOI: 10.1002/mrm.27197] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 02/08/2018] [Accepted: 03/06/2018] [Indexed: 12/20/2022]
Abstract
PURPOSE The purpose of this work was to study the contribution of liver [1-13 C]lactate to the lactate signal detected in the heart following injection of hyperpolarized [1-13 C]pyruvate. METHODS A slice-selective saturation scheme was incorporated into a hybrid metabolic imaging and spectroscopy approach to selectively presaturate lactate in the liver. Imaging and slice-selective spectroscopy of [1-13 C]pyruvate and its downstream metabolites were sequentially interleaved in the same experiment with optional presaturation of liver [1-13 C]lactate. Six healthy rats were measured, and metabolic data in the heart acquired with and without presaturation of liver lactate were compared. RESULTS When using liver lactate presaturation, a statistically significant reduction of the lactate/pyruvate ratio was observed in the spectroscopic data of the left ventricle (0.18 ± 0.03 versus 0.24 ± 0.04; p < .05) as well as in the imaging data of the blood pool (0.05 ± 0.01 versus 0.11 ± 0.01; p < .05). No significant difference in myocardial lactate was observed when using myocardium only as the region of interest in the imaging data (0.08 ± 0.01 versus 0.11 ± 0.02; p = .2). CONCLUSION Liver metabolism leads to statistically significant overestimation of cardiac lactate production in slice-selective or nonselective spectroscopic experiments. Therefore, metabolic imaging is preferred over spectroscopy to separate left-ventricular compartments within the slice and hence avoid contamination of cardiac lactate signals. Alternatively, presaturation pulses should be used in combination with spectroscopy approaches.
Collapse
Affiliation(s)
- Patrick Wespi
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Jonas Steinhauser
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Grzegorz Kwiatkowski
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| |
Collapse
|
30
|
Manning WJ. Review of Journal of Cardiovascular Magnetic Resonance (JCMR) 2015-2016 and transition of the JCMR office to Boston. J Cardiovasc Magn Reson 2017; 19:108. [PMID: 29284487 PMCID: PMC5747150 DOI: 10.1186/s12968-017-0423-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Accepted: 12/07/2017] [Indexed: 02/06/2023] Open
Abstract
The Journal of Cardiovascular Magnetic Resonance (JCMR) is the official publication of the Society for Cardiovascular Magnetic Resonance (SCMR). In 2016, the JCMR published 93 manuscripts, including 80 research papers, 6 reviews, 5 technical notes, 1 protocol, and 1 case report. The number of manuscripts published was similar to 2015 though with a 12% increase in manuscript submissions to an all-time high of 369. This reflects a decrease in the overall acceptance rate to <25% (excluding solicited reviews). The quality of submissions to JCMR continues to be high. The 2016 JCMR Impact Factor (which is published in June 2016 by Thomson Reuters) was steady at 5.601 (vs. 5.71 for 2015; as published in June 2016), which is the second highest impact factor ever recorded for JCMR. The 2016 impact factor means that the JCMR papers that were published in 2014 and 2015 were on-average cited 5.71 times in 2016.In accordance with Open-Access publishing of Biomed Central, the JCMR articles are published on-line in the order that they are accepted with no collating of the articles into sections or special thematic issues. For this reason, over the years, the Editors have felt that it is useful to annually summarize the publications into broad areas of interest or themes, so that readers can view areas of interest in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes with previously published JCMR papers to guide continuity of thought in the journal. In addition, I have elected to open this publication with information for the readership regarding the transition of the JCMR editorial office to the Beth Israel Deaconess Medical Center, Boston and the editorial process.Though there is an author publication charge (APC) associated with open-access to cover the publisher's expenses, this format provides a much wider distribution/availability of the author's work and greater manuscript citation. For SCMR members, there is a substantial discount in the APC. I hope that you will continue to send your high quality manuscripts to JCMR for consideration. Importantly, I also ask that you consider referencing recent JCMR publications in your submissions to the JCMR and elsewhere as these contribute to our impact factor. I also thank our dedicated Associate Editors, Guest Editors, and reviewers for their many efforts to ensure that the review process occurs in a timely and responsible manner and that the JCMR continues to be recognized as the leading publication in our field.
Collapse
Affiliation(s)
- Warren J Manning
- From the Journal of Cardiovascular Magnetic Resonance Editorial Office and the Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
31
|
Fuetterer M, Busch J, Peereboom SM, von Deuster C, Wissmann L, Lipiski M, Fleischmann T, Cesarovic N, Stoeck CT, Kozerke S. Hyperpolarized 13C urea myocardial first-pass perfusion imaging using velocity-selective excitation. J Cardiovasc Magn Reson 2017; 19:46. [PMID: 28637508 PMCID: PMC5480203 DOI: 10.1186/s12968-017-0364-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Accepted: 06/01/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized 13C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced 1H measurements in-vivo. METHODS The proposed excitation with an echo-planar imaging readout was implemented on a clinical CMR system. Dynamic myocardial stress perfusion images were acquired in six healthy pigs after bolus injection of hyperpolarized 13C urea with the velocity-selective vs. conventional excitation, as well as standard 1H gadolinium-enhanced images. Signal-to-noise, contrast-to-noise (CNR) and homogeneity of semi-quantitative perfusion measures were compared between methods based on first-pass signal-intensity time curves extracted from a mid-ventricular slice. Diagnostic feasibility is demonstrated in a case of septal infarction. RESULTS Velocity-selective excitation provides over three-fold reduction in blood pool signal with a two-fold increase in myocardial CNR. Extracted first-pass perfusion curves reveal a significantly reduced variability of semi-quantitative first-pass perfusion measures (12-20%) for velocity-selective excitation compared to conventional excitation (28-93%), comparable to that of reference 1H gadolinium data (9-15%). Overall image quality appears comparable between the velocity-selective hyperpolarized and gadolinium-enhanced imaging. CONCLUSION The feasibility of hyperpolarized 13C first-pass perfusion CMR has been demonstrated in swine. Comparison with reference 1H gadolinium data revealed sufficient data quality and indicates the potential of hyperpolarized perfusion imaging for human applications.
Collapse
Affiliation(s)
- Maximilian Fuetterer
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Julia Busch
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Sophie M. Peereboom
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Constantin von Deuster
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Lukas Wissmann
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Miriam Lipiski
- Division of Surgical Research, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Thea Fleischmann
- Division of Surgical Research, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Nikola Cesarovic
- Division of Surgical Research, University Hospital Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Christian T. Stoeck
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
| |
Collapse
|
32
|
Paiman EHM, Lamb HJ. When should we use contrast material in cardiac MRI? J Magn Reson Imaging 2017; 46:1551-1572. [PMID: 28480596 DOI: 10.1002/jmri.25754] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Accepted: 04/18/2017] [Indexed: 12/29/2022] Open
Abstract
At present, most of the cardiac magnetic resonance imaging (MRI) examinations rely on contrast-enhanced protocols, but noncontrast alternatives are emerging. Late gadolinium enhancement (LGE) imaging for the detection of myocardial scar can be considered the main cause for the embedding of cardiac MRI into the clinical routine. The novel noncontrast technique of native T1 mapping shows promise for tissue characterization in ischemic and nonischemic cardiomyopathy and may provide additional information over conventional LGE imaging. Technical issues, including measurements variability, still need to be resolved to facilitate a wide clinical application. Ischemia detection can be performed with contrast-based stress perfusion and contrast-free stress wall motion imaging. For coronary magnetic resonance angiography (MRA), protocols with and without contrast material have been developed. Research on coronary atherosclerotic plaque characterization has introduced new applications of contrast material. For MRA of the aorta, which traditionally relied on contrast administration, several noncontrast protocols have become available. This review provides an overview of when to use contrast material in cardiac and cardiac-related vascular MRI, summarizes the major imaging building blocks, and describes the diagnostic value of the available contrast-enhanced and noncontrast techniques. Contrast material in cardiac MRI should be used for LGE imaging for tissue characterization in ischemic or nonischemic cardiomyopathy and may be used for stress perfusion imaging for the detection of ischemia. In cardiac-related vascular MRI, use of contrast material should be avoided, unless high-quality angiography is required that cannot be obtained with noncontrast protocols. LEVEL OF EVIDENCE 5 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:1551-1572.
Collapse
Affiliation(s)
- Elisabeth H M Paiman
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Hildo J Lamb
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
33
|
Mou A, Zhang C, Li M, Jin F, Song Q, Liu A, Li Z. Evaluation of myocardial microcirculation using intravoxel incoherent motion imaging. J Magn Reson Imaging 2017; 46:1818-1828. [PMID: 28306208 DOI: 10.1002/jmri.25706] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Accepted: 03/02/2017] [Indexed: 11/07/2022] Open
Affiliation(s)
- Anna Mou
- Department of Radiology; First Affiliated Hospital of Dalian Medical University; Dalian P.R. China
| | - Chen Zhang
- Department of Radiology; First Affiliated Hospital of Dalian Medical University; Dalian P.R. China
| | - Mengying Li
- Department of Radiology; First Affiliated Hospital of Dalian Medical University; Dalian P.R. China
| | - Fengqiang Jin
- Department of Radiology; First Affiliated Hospital of Dalian Medical University; Dalian P.R. China
| | - Qingwei Song
- Department of Radiology; First Affiliated Hospital of Dalian Medical University; Dalian P.R. China
| | - Ailian Liu
- Department of Radiology; First Affiliated Hospital of Dalian Medical University; Dalian P.R. China
| | - Zhiyong Li
- Department of Radiology; First Affiliated Hospital of Dalian Medical University; Dalian P.R. China
| |
Collapse
|
34
|
Vandoorne K, Vandsburger MH, Jacobs I, Han Y, Dafni H, Nicolay K, Strijkers GJ. Noninvasive mapping of endothelial dysfunction in myocardial ischemia by magnetic resonance imaging using an albumin-based contrast agent. NMR IN BIOMEDICINE 2016; 29:1500-1510. [PMID: 27604064 DOI: 10.1002/nbm.3599] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Revised: 07/10/2016] [Accepted: 07/18/2016] [Indexed: 05/28/2023]
Abstract
Noninvasive preclinical methods for the characterization of myocardial vascular function are crucial to an understanding of the dynamics of ischemic cardiac disease. Ischemic heart disease is associated with myocardial endothelial dysfunction, resulting in leakage of plasma albumin into the extravascular space. These features can be harnessed in a novel noninvasive three-dimensional magnetic resonance imaging method to measure fractional blood volume (fBV) and vascular permeability (permeability-surface area product, PS) using labeled albumin as a blood pool contrast agent. C57BL/6 mice were imaged before and 3 days after myocardial infarction (MI). Following the quantification of endogenous myocardial R1 , the dynamics of intravenously injected albumin-based contrast agent, extravasating from permeable myocardial blood vessels, were tracked on short-axis magnetic resonance images of the entire heart. This study successfully discriminated between infarcted and remote regions at 3 days post-infarct, based on a reduced fBV and increased PS in the infarcted region. These findings were confirmed using ex vivo fluorescence imaging and histology. We have demonstrated a novel method to quantify blood volume and permeability in the infarcted myocardium, providing an imaging biomarker for the assessment of endothelial dysfunction. This method has the potential to three-dimensionally visualize subtle changes in myocardial permeability and to track endothelial function for longitudinal cardiac studies determining pathophysiological processes during infarct healing.
Collapse
Affiliation(s)
- Katrien Vandoorne
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
| | | | - I Jacobs
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Y Han
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Hagit Dafni
- Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, Israel
| | - Klaas Nicolay
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Gustav J Strijkers
- Biomedical NMR, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Biomedical Engineering and Physics, Academic Medical Center (AMC), Amsterdam, the Netherlands
| |
Collapse
|
35
|
Stäb D, Roessler J, O'Brien K, Hamilton-Craig C, Barth M. ECG Triggering in Ultra-High Field Cardiovascular MRI. ACTA ACUST UNITED AC 2016; 2:167-174. [PMID: 30042961 PMCID: PMC6024401 DOI: 10.18383/j.tom.2016.00193] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Cardiac magnetic resonance imaging at ultra-high field (B0 ≥ 7 T) potentially provides improved resolution and new opportunities for tissue characterization. Although an accurate synchronization of the acquisition to the cardiac cycle is essential, electrocardiogram (ECG) triggering at ultra-high field can be significantly impacted by the magnetohydrodynamic (MHD) effect. Blood flow within a static magnetic field induces a voltage, which superimposes the ECG and often affects the recognition of the R-wave. The MHD effect scales with B0 and is particularly pronounced at ultra-high field creating triggering-related image artifacts. Here, we investigated the performance of a conventional 3-lead ECG trigger device and a state-of-the-art trigger algorithm for cardiac ECG synchronization at 7 T. We show that by appropriate subject preparation and by including a learning phase for the R-wave detection outside of the magnetic field, reliable ECG triggering is feasible in healthy subjects at 7 T without additional equipment. Ultra-high field cardiac imaging was performed with the ECG signal and the trigger events recorded in 8 healthy subjects. Despite severe ECG signal distortions, synchronized imaging was successfully performed. Recorded ECG signals, vectorcardiograms, and large consistency in trigger event spacing indicate high accuracy for R-wave detection.
Collapse
Affiliation(s)
- Daniel Stäb
- The Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia.,Department of Diagnostic and Interventional Radiology, University of Würzburg, Würzburg, Germany
| | | | | | - Christian Hamilton-Craig
- Richard Slaughter Centre of Excellence in CVMRI, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Markus Barth
- The Centre for Advanced Imaging, The University of Queensland, Brisbane, Queensland, Australia
| |
Collapse
|