1
|
Fujita Y, Khoo HM, Kimoto Y, Emura T, Iwata T, Matsuhashi T, Miura S, Yanagisawa T, Hosomi K, Tani N, Oshino S, Hirata M, Kishima H. Accuracy of Boltless Frame-Based Stereo-Electroencephalography Electrode Implantation. Oper Neurosurg (Hagerstown) 2024:01787389-990000000-01196. [PMID: 38888309 DOI: 10.1227/ons.0000000000001209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/13/2024] [Indexed: 06/20/2024] Open
Abstract
BACKGROUND AND OBJECTIVES Boltless implantation of stereo-electroencephalography electrode is a useful alternative especially when anchor bolt is not available such as in country with limited resources or is less appropriate such as placement in patients with thin skull or at the occiput area, despite some drawbacks including potential dislodgement. While the accuracy of implantation using anchor bolt is well-studied, data on boltless implantation remain scarce. This study aimed to reveal the accuracy, permissible error for actual placement of electrodes within the grey matter, and delayed electrode dislodgement in boltless implantation. METHODS A total of 120 electrodes were implanted in 15 patients using a Leksell Stereotactic G Frame with each electrode fixed on the scalp using sutures. Target point error was defined as the Euclidean distance between the planned target and the electrode tip on immediate postimplantation computed tomography. Similarly, delayed dislodgement was defined as the Euclidean distance between the electrode tips on immediate postimplantation computed tomography and delayed MRI. The factors affecting accuracy were evaluated using multiple linear regression. The permissible error was defined as the largest target point error that allows the maximum number of planned gray matter electrode contacts to be actually placed within the gray matter as intended. RESULTS The median (IQR) target point error was 2.6 (1.7-3.5) mm, and the permissible error was 3.2 mm. The delayed dislodgement, with a median (IQR) of 2.2 (1.4-3.3) mm, was dependent on temporal muscle penetration (P = 5.0 × 10-4), scalp thickness (P < 5.1 × 10-3), and insertion angle (P = 3.4 × 10-3). CONCLUSION Boltless implantation of stereo-electroencephalography electrode offers an accuracy comparable to those using anchor bolt. During the planning of boltless implantation, target points should be placed within 3.2 mm from the gray-white matter junction and a possible delayed dislodgement of 2.2 mm should be considered.
Collapse
Affiliation(s)
- Yuya Fujita
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Hui Ming Khoo
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Yuki Kimoto
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Takuto Emura
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Takamitsu Iwata
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Takahiro Matsuhashi
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Shimpei Miura
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Takufumi Yanagisawa
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Koichi Hosomi
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Naoki Tani
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Satoru Oshino
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Masayuki Hirata
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| | - Haruhiko Kishima
- Department of Neurosurgery, Osaka University Graduate School of Medicine, Suita, Japan
- Epilepsy Center, Osaka University Hospital, Suita, Japan
| |
Collapse
|
2
|
Collavini S, Pérez JJ, Berjano E, Fernández-Corazza M, Oddo S, Irastorza RM. Impact of surrounding tissue-type and peri-electrode gap in stereoelectroencephalography guided (SEEG) radiofrequency thermocoagulation (RF-TC): a computational study. Int J Hyperthermia 2024; 41:2364721. [PMID: 38880496 DOI: 10.1080/02656736.2024.2364721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 06/01/2024] [Indexed: 06/18/2024] Open
Abstract
PURPOSE To use computational modeling to provide a complete and logical description of the electrical and thermal behavior during stereoelectroencephalography-guided (SEEG) radiofrequency thermo-coagulation (RF-TC). METHODS A coupled electrical-thermal model was used to obtain the temperature distributions in the tissue during RF-TC. The computer model was first validated by an ex vivo model based on liver fragments and later used to study the impact of three different factors on the coagulation zone size: 1) the difference in the tissue surrounding the electrode (gray/white matter), 2) the presence of a peri-electrode gap occupied by cerebrospinal fluid (CSF), and 3) the energy setting used (power-duration). RESULTS The model built for the experimental validation was able to predict both the evolution of impedance and the short diameter of the coagulation zone (error < 0.01 mm) reasonably well but overestimated the long diameter by 2 - 3 mm. After adapting the model to clinical conditions, the simulation showed that: 1) Impedance roll-off limited the coagulation size but involved overheating (around 100 °C); 2) The type of tissue around the contacts (gray vs. white matter) had a moderate impact on the coagulation size (maximum difference 0.84 mm), and 3) the peri-electrode gap considerably altered the temperature distributions, avoided overheating, although the diameter of the coagulation zone was not very different from the no-gap case (<0.2 mm). CONCLUSIONS This study showed that computer modeling, especially subject- and scenario-specific modeling, can be used to estimate in advance the electrical and thermal performance of the RF-TC in brain tissue.
Collapse
Affiliation(s)
- Santiago Collavini
- Institute of Engineering and Agronomy, National University Arturo Jauretche, Buenos Aires, Argentina
- Neurosciences and Complex Systems Unit (EnyS), CONICET, Hosp. "El Cruce N. Kirchner", National University A. Jauretche (UNAJ), Buenos Aires, Argentina
| | - Juan J Pérez
- BioMIT, Departamento de Ingeniería Electrónica, Universitat Politècnica de València, València, Spain
| | - Enrique Berjano
- BioMIT, Departamento de Ingeniería Electrónica, Universitat Politècnica de València, València, Spain
| | - Mariano Fernández-Corazza
- Research Institute of Electronics, Control and Signal Processing (LEICI), National University of La Plata-CONICET, La Plata, Argentina
| | - Silvia Oddo
- Neurosciences and Complex Systems Unit (EnyS), CONICET, Hosp. "El Cruce N. Kirchner", National University A. Jauretche (UNAJ), Buenos Aires, Argentina
| | - Ramiro M Irastorza
- Institute of Engineering and Agronomy, National University Arturo Jauretche, Buenos Aires, Argentina
- Institute of Physics of Liquids and Biological Systems (IFLySiB CONICET La Plata), La Plata, Argentina
- Granular Materials Group, Department of Mechanical Engineering, La Plata Regional Faculty, National Technological University, La Plata, Argentina
| |
Collapse
|
3
|
Zauli FM, Del Vecchio M, Pigorini A, Russo S, Massimini M, Sartori I, Cardinale F, d'Orio P, Mikulan E. Localizing hidden Interictal Epileptiform Discharges with simultaneous intracerebral and scalp high-density EEG recordings. J Neurosci Methods 2024:110193. [PMID: 38871302 DOI: 10.1016/j.jneumeth.2024.110193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 05/02/2024] [Accepted: 06/08/2024] [Indexed: 06/15/2024]
Abstract
BACKGROUND Scalp EEG is one of the main tools in the clinical evaluation of epilepsy. In some cases intracranial Interictal Epileptiform Discharges (IEDs) are not visible from the scalp. Recent studies have shown the feasibility of revealing them in the EEG if their timings are extracted from simultaneous intracranial recordings, but their potential for the localization of the epileptogenic zone is not yet well defined. NEW METHOD We recorded simultaneous high-density EEG (HD-EEG) and stereo-electroencephalography (SEEG) during interictal periods in 8 patients affected by drug-resistant focal epilepsy. We identified IEDs in the SEEG and systematically analyzed the time-locked signals on the EEG by means of evoked potentials, topographical analysis and Electrical Source Imaging (ESI). The dataset has been standardized and is being publicly shared. RESULTS Our results showed that IEDs that were not clearly visible at single-trials could be uncovered by averaging, in line with previous reports. They also showed that their topographical voltage distributions matched the position of the SEEG electrode where IEDs had been identified, and that ESI techniques can reconstruct it with an accuracy of ~2 cm. Finally, the present dataset provides a reference to test the accuracy of different methods and parameters. COMPARISON WITH EXISTING METHODS Our study is the first to systematically compare ESI methods on simultaneously recorded IEDs, and to share a public resource with in-vivo data for their evaluation. CONCLUSIONS Simultaneous HD-EEG and SEEG recordings can unveil hidden IEDs whose origins can be reconstructed using topographical and ESI analyses, but results depend on the selected methods and parameters.
Collapse
Affiliation(s)
- Flavia Maria Zauli
- Department of Philosophy "P. Martinetti". Università degli Studi di Milano, Milan, Italy; Department of Biomedical and Clinical Sciences "L. Sacco". Università degli Studi di Milano, Milan, Italy; ASST GOM Niguarda. Piazza dell'Ospedale Maggiore 3, Milan, Italy
| | - Maria Del Vecchio
- Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy
| | - Andrea Pigorini
- Department of Biomedical, Surgical and Dental Sciences. Università degli Studi di Milano, Milan, Italy; UOC Maxillo-facial Surgery and dentistry, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy
| | - Simone Russo
- Department of Biomedical and Clinical Sciences "L. Sacco". Università degli Studi di Milano, Milan, Italy; Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Marcello Massimini
- Department of Biomedical and Clinical Sciences "L. Sacco". Università degli Studi di Milano, Milan, Italy; Istituto Di Ricovero e Cura a Carattere Scientifico, Fondazione Don Carlo Gnocchi, Milan, Italy
| | - Ivana Sartori
- ASST GOM Niguarda. Piazza dell'Ospedale Maggiore 3, Milan, Italy
| | - Francesco Cardinale
- ASST GOM Niguarda. Piazza dell'Ospedale Maggiore 3, Milan, Italy; Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy; Department of Medicine and Surgery, Unit of Neuroscience, Università degli Studi di Parma, Parma, Italy
| | - Piergiorgio d'Orio
- ASST GOM Niguarda. Piazza dell'Ospedale Maggiore 3, Milan, Italy; Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy; Department of Medicine and Surgery, Unit of Neuroscience, Università degli Studi di Parma, Parma, Italy
| | - Ezequiel Mikulan
- Department of Health Sciences. Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
4
|
Abarrategui B, Pelliccia V, Giovannelli G, Nichelatti M, Valenzano S, Mikulan E, Pigorini A, Revay M, Scarpa P, Tassi L. New stimulation procedures for language mapping in stereo-EEG. Epilepsia 2024; 65:1720-1729. [PMID: 38581367 DOI: 10.1111/epi.17963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 03/08/2024] [Accepted: 03/11/2024] [Indexed: 04/08/2024]
Abstract
OBJECTIVE Cortical intracerebral electrical stimulation is an important tool for language mapping in the presurgical work-up of patients with drug-resistant focal epilepsy. Language mapping with stereo-electroencephalography (EEG) is usually performed by high-frequency stimulations (HFS: 50 Hz), whereas low-frequency stimulations (LFS: 1 Hz) are usually considered useful for primary cortices mapping. Little is known in literature about "intermediate" frequencies (IFS: 6-15 Hz). Our objective is to explore the clinical usefulness of IFS in language mapping and identify factors, beyond the electrical parameters, that impact the mapping. METHODS We studied 23 patients submitted to stereo-EEG for presurgical evaluation. Language mapping was performed in the anterior, posterior and/or basal language region of the dominant hemisphere for language. We included all contact positions within these regions stimulated by HFS (50 Hz, 5 s, 1-3 mA) and IFS (6-15 Hz, 15 s, 5 mA). We compared the capability of both stimulation methods to induce a language deficit without afterdischarges (ADs), and we analyzed factors related to clinical examination, region, and stimulation technique by multivariate analysis. RESULTS A total of 211 stimulations (98 HFS, 113 IFS) in 70 cortical sites within the anterior (84 stimulations), posterior (137), and basal language region (60) were included. IFS induced more frequently language deficits not associated to AD compared to HFS (37.1% vs 25.7%, p = .0043), whereas HFS provoked more diffuse AD (34.7% vs 15.0%, p = .001). Investigating multiple language functions increased the probability of revealing a deficit (odds ratio [OR] 3.16, p = .0016), independently of the stimulation method. SIGNIFICANCE IFS are valuable for language mapping, thereby improving the probability of inducing a clinical deficit not accompanied by an AD. The completeness of the clinical examination independently affects the sensitivity of the mapping. IFS are a new tool with potential usefulness for the cortical mapping of other associative cortical regions.
Collapse
Affiliation(s)
- Belén Abarrategui
- Neurology Department, Hospital Universitario Puerta de Hierro, Majadahonda, Spain
- Claudio Munari Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Istituto di Neuroscienze, Consiglio Nazionale delle Ricerche, Parma, Italy
| | - Veronica Pelliccia
- Claudio Munari Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Ginevra Giovannelli
- Claudio Munari Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Department of Neurology 2, Careggi University Hospital, Florence, Italy
| | - Michele Nichelatti
- Service of Biostatistics, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Serena Valenzano
- Center for Neuroscience, University of Camerino, Camerino, Italy
- Department of Biomedical and Clinical Sciences "L. Sacco", Università Degli Studi di Milano, Milan, Italy
| | - Ezequiel Mikulan
- Department of Health Sciences, Università Degli Studi di Milano, Milan, Italy
| | - Andrea Pigorini
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
- UOC Maxillo-facial Surgery and Dentistry, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy
| | - Martina Revay
- Claudio Munari Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Department of Medicine and Surgery, Unit of Neuroscience, University of Parma, Parma, Italy
| | - Pina Scarpa
- Department of Neuroscience, Cognitive Neuropsychology Centre, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Laura Tassi
- Claudio Munari Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| |
Collapse
|
5
|
Di Giacomo R, Burini A, Chiarello D, Pelliccia V, Deleo F, Garbelli R, de Curtis M, Tassi L, Gnatkovsky V. Ictal fast activity chirps as markers of the epileptogenic zone. Epilepsia 2024; 65:e97-e103. [PMID: 38686942 DOI: 10.1111/epi.17995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 04/11/2024] [Accepted: 04/11/2024] [Indexed: 05/02/2024]
Abstract
The identification of the epileptogenic zone (EZ) boundaries is crucial for effective focal epilepsy surgery. We verify the value of a neurophysiological biomarker of focal ictogenesis, characterized by a low-voltage fast-activity ictal pattern (chirp) recorded with intracerebral electrodes during invasive presurgical monitoring (stereoelectroencephalography [SEEG]). The frequency content of SEEG signals was retrospectively analyzed with semiautomatic software in 176 consecutive patients with focal epilepsies that either were cryptogenic or presented with discordant anatomoelectroclinical findings. Fast activity seizure patterns with the spectrographic features of chirps were confirmed by computer-assisted analysis in 95.4% of patients who presented with heterogeneous etiologies and diverse lobar location of the EZ. Statistical analysis demonstrated (1) correlation between seizure outcome and concordance of sublobar regions included in the EZ defined by visual analysis and chirp-generating regions, (2) high concordance in contact-by contact analysis of 68 patients with Engel class Ia outcome, and (3) that discordance between chirp location and the visually outlined EZ correlated with worse seizure outcome. Seizure outcome analysis confirms the fast activity chirp pattern is a reproducible biomarker of the EZ in a heterogeneous group of patients undergoing SEEG.
Collapse
Affiliation(s)
- Roberta Di Giacomo
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Alessandra Burini
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
- Clinical Neurology, Department of Medicine (DAME), University of Udine, Udine, Italy
| | - Daniela Chiarello
- "Claudio Munari" Epilepsy Surgery Center, Niguarda Hospital, Milan, Italy
| | - Veronica Pelliccia
- "Claudio Munari" Epilepsy Surgery Center, Niguarda Hospital, Milan, Italy
| | - Francesco Deleo
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Rita Garbelli
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Marco de Curtis
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Laura Tassi
- "Claudio Munari" Epilepsy Surgery Center, Niguarda Hospital, Milan, Italy
| | - Vadym Gnatkovsky
- Epilepsy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
- Department of Epileptology, Universitätsklinikum Bonn, Bonn, Germany
| |
Collapse
|
6
|
Del Vecchio M, Bontemps B, Lance F, Gannerie A, Sipp F, Albertini D, Cassani CM, Chatard B, Dupin M, Lachaux JP. Introducing HiBoP: a Unity-based visualization software for large iEEG datasets. J Neurosci Methods 2024; 409:110179. [PMID: 38823595 DOI: 10.1016/j.jneumeth.2024.110179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 05/02/2024] [Accepted: 05/22/2024] [Indexed: 06/03/2024]
Abstract
BACKGROUND Intracranial EEG data offer a unique spatio-temporal precision to investigate human brain functions. Large datasets have become recently accessible thanks to new iEEG data-sharing practices and tighter collaboration with clinicians. Yet, the complexity of such datasets poses new challenges, especially regarding the visualization and anatomical display of iEEG. NEW METHOD We introduce HiBoP, a multi-modal visualization software specifically designed for large groups of patients and multiple experiments. Its main features include the dynamic display of iEEG responses induced by tasks/stimulations, the definition of Regions and electrodes Of Interest, and the shift between group-level and individual-level 3D anatomo-functional data. RESULTS We provide a use-case with data from 36 patients to reveal the global cortical dynamics following tactile stimulation. We used HiBoP to visualize high-gamma responses [50-150 Hz], and define three major response components in primary somatosensory and premotor cortices and parietal operculum. COMPARISON WITH EXISTING METHODS(S) Several iEEG softwares are now publicly available with outstanding analysis features. Yet, most were developed in languages (Python/Matlab) chosen to facilitate the inclusion of new analysis by users, rather than the quality of the visualization. HiBoP represents a visualization tool developed with videogame standards (Unity/C#), and performs detailed anatomical analysis rapidly, across multiple conditions, patients, and modalities with an easy export toward third-party softwares. CONCLUSION HiBoP provides a user-friendly environment that greatly facilitates the exploration of large iEEG datasets, and helps users decipher subtle structure/function relationships.
Collapse
Affiliation(s)
- Maria Del Vecchio
- Istituto di Neuroscienze, Consiglio Nazionale delle Ricerche, Parma 43125, Italy
| | - Benjamin Bontemps
- Lyon Neuroscience Research Center, EDUWELL team, INSERM UMRS 1028, CNRS UMR 5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon F-69000, France
| | - Florian Lance
- Lyon Neuroscience Research Center, EDUWELL team, INSERM UMRS 1028, CNRS UMR 5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon F-69000, France
| | - Adrien Gannerie
- Lyon Neuroscience Research Center, EDUWELL team, INSERM UMRS 1028, CNRS UMR 5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon F-69000, France
| | - Florian Sipp
- Lyon Neuroscience Research Center, EDUWELL team, INSERM UMRS 1028, CNRS UMR 5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon F-69000, France
| | - Davide Albertini
- Dipartimento di Medicina e Chirurgia, Università di Parma, Via Volturno 39, Parma 43125, Italy
| | - Chiara Maria Cassani
- Istituto di Neuroscienze, Consiglio Nazionale delle Ricerche, Parma 43125, Italy; Department of School of Advanced Studies, University of Camerino, Italy
| | - Benoit Chatard
- Lyon Neuroscience Research Center, EDUWELL team, INSERM UMRS 1028, CNRS UMR 5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon F-69000, France
| | - Maryne Dupin
- Lyon Neuroscience Research Center, EDUWELL team, INSERM UMRS 1028, CNRS UMR 5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon F-69000, France
| | - Jean-Philippe Lachaux
- Lyon Neuroscience Research Center, EDUWELL team, INSERM UMRS 1028, CNRS UMR 5292, Université Claude Bernard Lyon 1, Université de Lyon, Lyon F-69000, France.
| |
Collapse
|
7
|
Hines K, Smit RD, Vinjamuri S, Momin AA, Fayed I, Ebede K, Atik AF, Matias CM, Sharan A, Wu C. Learning Curves during Implementation of Robotic Stereotactic Surgery. Stereotact Funct Neurosurg 2024:1-7. [PMID: 38735282 DOI: 10.1159/000538379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Accepted: 03/13/2024] [Indexed: 05/14/2024]
Abstract
INTRODUCTION Adoption of robotic techniques is increasing for neurosurgical applications. Common cranial applications include stereoelectroencephalography (sEEG) and deep brain stimulation (DBS). For surgeons to implement robotic techniques in these procedures, realistic learning curves must be anticipated for surgeons to overcome the challenges of integrating new techniques into surgical workflow. One such way of quantifying learning curves in surgery is cumulative sum (CUSUM) analysis. METHODS Here, the authors present retrospective review of stereotactic cases to perform a CUSUM analysis of operative time for robotic cases at a single institution performed by 2 surgeons. The authors demonstrate learning phase durations of 20 and 16 cases in DBS and sEEG, respectively. RESULTS After plateauing of operative time, mastery phases started at cases 132 and 72 in DBS and sEEG. A total of 273 cases (188 DBS and 85 sEEG) were included in the study. The authors observed a learning plateau concordant with change of location of surgery after exiting the learning phase. CONCLUSION This study demonstrates the learning curve of 2 stereotactic workflows when integrating robotics as well as being the first study to examine the robotic learning curve in DBS via CUSUM analysis. This work provides data on what surgeons may expect when integrating this technology into their practice for cranial applications.
Collapse
Affiliation(s)
- Kevin Hines
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| | - Rupert D Smit
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| | - Shreya Vinjamuri
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| | - Arbaz A Momin
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| | - Islam Fayed
- Department of Neurological Surgery, Cooper University Health Care, Camden, New Jersey, USA
| | - Kenechi Ebede
- Department of Anesthesiology and Perioperative Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Ahmet F Atik
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| | - Caio Marconato Matias
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| | - Ashwini Sharan
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| | - Chengyuan Wu
- Department of Neurological Surgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania, USA
| |
Collapse
|
8
|
Russo S, Claar L, Marks L, Krishnan G, Furregoni G, Zauli FM, Hassan G, Solbiati M, d’Orio P, Mikulan E, Sarasso S, Rosanova M, Sartori I, Bazhenov M, Pigorini A, Massimini M, Koch C, Rembado I. Thalamic feedback shapes brain responses evoked by cortical stimulation in mice and humans. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.01.31.578243. [PMID: 38352535 PMCID: PMC10862802 DOI: 10.1101/2024.01.31.578243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Cortical stimulation with single pulses is a common technique in clinical practice and research. However, we still do not understand the extent to which it engages subcortical circuits which contribute to the associated evoked potentials (EPs). Here we find that cortical stimulation generates remarkably similar EPs in humans and mice, with a late component similarly modulated by the subject's behavioral state. We optogenetically dissect the underlying circuit in mice, demonstrating that the late component of these EPs is caused by a thalamic hyperpolarization and rebound. The magnitude of this late component correlates with the bursting frequency and synchronicity of thalamic neurons, modulated by the subject's behavioral state. A simulation of the thalamo-cortical circuit highlights that both intrinsic thalamic currents as well as cortical and thalamic GABAergic neurons contribute to this response profile. We conclude that the cortical stimulation engages cortico-thalamo-cortical circuits highly preserved across different species and stimulation modalities.
Collapse
Affiliation(s)
- Simone Russo
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
- Department of Philosophy ‘Piero Martinetti’, University of Milan, Milan, Italy
- Brain and Consciousness, Allen Institute, Seattle, United States
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Leslie Claar
- Brain and Consciousness, Allen Institute, Seattle, United States
| | - Lydia Marks
- Brain and Consciousness, Allen Institute, Seattle, United States
| | - Giri Krishnan
- Department of Medicine, University of California San Diego, La Jolla, CA, 92093, USA
| | - Giulia Furregoni
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
| | - Flavia Maria Zauli
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
- Department of Philosophy ‘Piero Martinetti’, University of Milan, Milan, Italy
- ASST Grande Ospedale Metropolitano Niguarda, “C. Munari” Epilepsy Surgery Centre, Department of Neuroscience, Italy
| | - Gabriel Hassan
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
- Department of Philosophy ‘Piero Martinetti’, University of Milan, Milan, Italy
| | - Michela Solbiati
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
- ASST Grande Ospedale Metropolitano Niguarda, “C. Munari” Epilepsy Surgery Centre, Department of Neuroscience, Italy
| | - Piergiorgio d’Orio
- ASST Grande Ospedale Metropolitano Niguarda, “C. Munari” Epilepsy Surgery Centre, Department of Neuroscience, Italy
- University of Parma, Parma 43121, Italy
| | - Ezequiel Mikulan
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
| | - Simone Sarasso
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
| | - Mario Rosanova
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
| | - Ivana Sartori
- ASST Grande Ospedale Metropolitano Niguarda, “C. Munari” Epilepsy Surgery Centre, Department of Neuroscience, Italy
| | - Maxim Bazhenov
- Department of Medicine, University of California San Diego, La Jolla, CA, 92093, USA
- Neurosciences Graduate Program, University of California San Diego, La Jolla, CA, 92093, USA
| | - Andrea Pigorini
- Department of Biomedical, Surgical and Dental Sciences, Università degli Studi di Milano, Milan 20122, Italy
- UOC Maxillo-facial Surgery and dentistry, Fondazione IRCCS Cà Granda, Ospedale Maggiore Policlinico, Milan, Italy
| | - Marcello Massimini
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan 20157, Italy
- Istituto Di Ricovero e Cura a Carattere Scientifico, Fondazione Don Carlo Gnocchi, Milan 20122, Italy
- Azrieli Program in Brain, Mind and Consciousness, Canadian Institute for Advanced Research (CIFAR), Toronto, Ontario M5G 1M1, Canada
| | - Christof Koch
- Brain and Consciousness, Allen Institute, Seattle, United States
| | - Irene Rembado
- Brain and Consciousness, Allen Institute, Seattle, United States
| |
Collapse
|
9
|
Chen J, Cheng X, Huang J, Luo P, Mao D, Yang H. Three-Dimensional Structure Light Robot-Assisted Frameless Stereotactic Brain Biopsy. Oper Neurosurg (Hagerstown) 2024:01787389-990000000-01107. [PMID: 38578714 DOI: 10.1227/ons.0000000000001138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Accepted: 01/03/2024] [Indexed: 04/07/2024] Open
Abstract
BACKGROUND AND OBJECTIVES To assess the feasibility, accuracy, and safety of 3-dimensional (3D) structure light robot-assisted frameless stereotactic brain biopsy. METHODS Five consecutive patients (3 males, 2 females) were included in this study. The patients' clinical, imaging, and histological data were analyzed, and all patients received a 3D structure light robot-assisted frameless stereotactic brain biopsy. The raw and/or analyzed data of the study are available from the corresponding author. RESULTS The statistical results showed a mean age of 59.6 years (range 40-70 years), a mean target depth of 60.9 mm (range 53.5-65.8 mm), a mean radial error of 1.2 ± 0.7 mm (mean ± SD), a mean depth error of 0.7 ± 0.3 mm, and a mean absolute tip error of 1.5 ± 0.6 mm. The calculated Pearson product-moment correlation coefficient (r = 0.23) revealed no correlation between target depth and absolute tip error. All biopsy needles were placed in line with the planned trajectory successfully, and diagnostic specimens were harvested in all cases. Histopathological analysis revealed lymphoma (2 cases), lung adenocarcinoma (1 case), glioblastoma multiforme (1 case), and oligodendroglioma (1 case). CONCLUSION Surface registration using the 3D structure light technique is fast and precise because of the achievable million-scale point cloud data of the head and face. 3D structure light robot-assisted frameless stereotactic brain biopsy is feasible, accurate, and safe.
Collapse
Affiliation(s)
- Jie Chen
- Department of Neuro-Oncology, Chongqing University Cancer Hospital, Chongqing, China
| | | | | | | | | | | |
Collapse
|
10
|
Myrov V, Siebenhühner F, Juvonen JJ, Arnulfo G, Palva S, Palva JM. Rhythmicity of neuronal oscillations delineates their cortical and spectral architecture. Commun Biol 2024; 7:405. [PMID: 38570628 PMCID: PMC10991572 DOI: 10.1038/s42003-024-06083-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 03/20/2024] [Indexed: 04/05/2024] Open
Abstract
Neuronal oscillations are commonly analyzed with power spectral methods that quantify signal amplitude, but not rhythmicity or 'oscillatoriness' per se. Here we introduce a new approach, the phase-autocorrelation function (pACF), for the direct quantification of rhythmicity. We applied pACF to human intracerebral stereoelectroencephalography (SEEG) and magnetoencephalography (MEG) data and uncovered a spectrally and anatomically fine-grained cortical architecture in the rhythmicity of single- and multi-frequency neuronal oscillations. Evidencing the functional significance of rhythmicity, we found it to be a prerequisite for long-range synchronization in resting-state networks and to be dynamically modulated during event-related processing. We also extended the pACF approach to measure 'burstiness' of oscillatory processes and characterized regions with stable and bursty oscillations. These findings show that rhythmicity is double-dissociable from amplitude and constitutes a functionally relevant and dynamic characteristic of neuronal oscillations.
Collapse
Affiliation(s)
- Vladislav Myrov
- Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland.
| | - Felix Siebenhühner
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- BioMag Laboratory, HUS Medical Imaging Center, Helsinki, Finland
| | - Joonas J Juvonen
- Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
| | - Gabriele Arnulfo
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- Department of Informatics, Bioengineering, Robotics and System Engineering, University of Genoa, Genoa, Italy
| | - Satu Palva
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- Centre for Cognitive Neuroimaging, School of Psychology and Neuroscience, University of Glasgow, Glasgow, UK
| | - J Matias Palva
- Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- Centre for Cognitive Neuroimaging, School of Psychology and Neuroscience, University of Glasgow, Glasgow, UK
| |
Collapse
|
11
|
Du C, Wang L, Yan J, Li G, Wu Y, Zhao G, Cui D, Jin W, Yin S. The Association Between Trajectory-Skull Angle and Accuracy of Stereoelectroencephalography Electrode Implantation in Drug-Resistant Epilepsy. World Neurosurg 2024; 184:e408-e416. [PMID: 38309654 DOI: 10.1016/j.wneu.2024.01.139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 01/24/2024] [Indexed: 02/05/2024]
Abstract
OBJECTIVE To analyze the relationship between trajectory-skull angle and stereoelectroencephalography electrode implantation accuracy in drug-resistant epilepsy patients, aiming to guide clinical electrode placement and enhance surgical precision and safety. METHODS We conducted a retrospective analysis of medical records and surgical characteristics of 32 consecutive patients diagnosed with drug-resistant epilepsy, who underwent stereoelectroencephalography procedures at our center from June 2020 to June 2023. To evaluate the accuracy of electrode implantation, we utilized preoperative and postoperative computed tomography scans fused with SinoPlan software-planned trajectories. Entry radial error and target vector error were assessed as measurements of electrode implantation accuracy. RESULTS After adjusting for confounders, we found a significant positive correlation between trajectory-skull angle and entry radial error (β = 0.02, 95% CI: 0.01-0.03, P < 0.001). Likewise, a significant positive correlation existed between trajectory-skull angle and target vector error in all three models (β = 0.03, 95% CI: 0.01-0.04, P < 0.001). Additionally, a U-shaped relationship between trajectory-skull angle and target vector error was identified using smooth curve fitting. This U-shaped pattern persisted in both frame-based and robot-guided stereotactic techniques. According to the two-piecewise linear regression model, the inflection points were 9° in the frame-based group and 16° in the robot-guided group. CONCLUSIONS This study establishes a significant positive linear correlation between trajectory-skull angle and entry radial error, along with a distinctive U-shaped pattern in the relationship between trajectory-skull angle and target vector error. Our findings suggest that trajectory-skull angles of 9° (frame-based) and 16° (robot-guided) may optimize the accuracy of target vector error.
Collapse
Affiliation(s)
- Chuan Du
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China; Department of Neurosurgery, Affiliated Hospital of Chengdu University, Chengdu, China
| | - Le Wang
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China
| | - Jingtao Yan
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Guangfeng Li
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Yuzhang Wu
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Guangrui Zhao
- Clinical College of Neurology, Neurosurgery and Neurorehabilitation, Tianjin Medical University, Tianjin, China
| | - Deqiu Cui
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China
| | - Weipeng Jin
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China
| | - Shaoya Yin
- Department of Neurosurgery, Huanhu Hospital, Tianjin University, Tianjin, China.
| |
Collapse
|
12
|
Kullmann A, Akberali F, Van Gompel JJ, McGovern RA, Marsh WR, Kridner D, Diaz-Botia CA, Park MC. Implantation accuracy of novel polyimide stereotactic electroencephalographic depth electrodes-a human cadaveric study. FRONTIERS IN MEDICAL TECHNOLOGY 2024; 6:1320762. [PMID: 38456122 PMCID: PMC10917981 DOI: 10.3389/fmedt.2024.1320762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Accepted: 02/12/2024] [Indexed: 03/09/2024] Open
Abstract
Introduction Stereoelectroencephalography (sEEG) is a minimally invasive procedure that uses depth electrodes stereotactically implanted into brain structures to map the origin and propagation of seizures in epileptic patients. Implantation accuracy of sEEG electrodes plays a critical role in the safety and efficacy of the procedure. This study used human cadaver heads, simulating clinical practice, to evaluate (1) neurosurgeon's ability to implant a new thin-film polyimide sEEG electrode according to the instructions for use (IFU), and (2) implantation accuracy. Methods Four neurosurgeons (users) implanted 24 sEEG electrodes into two cadaver heads with the aid of the ROSA robotic system. Usability was evaluated using a questionnaire that assessed completion of all procedure steps per IFU and user errors. For implantation accuracy evaluation, planned electrode trajectories were compared with post-implantation trajectories after fusion of pre- and postoperative computer tomography (CT) images. Implantation accuracy was quantified using the Euclidean distance for entry point error (EPE) and target point error (TPE). Results All sEEG electrodes were successfully placed following the IFU without user errors, and post-implant survey of users showed favorable handling characteristics. The EPE was 1.28 ± 0.86 mm and TPE was 1.61 ± 0.89 mm. Long trajectories (>50 mm) had significantly larger EPEs and TPEs than short trajectories (<50 mm), and no differences were found between orthogonal and oblique trajectories. Accuracies were similar or superior to those reported in the literature when using similar experimental conditions, and in the same range as those reported in patients. Discussion The results demonstrate that newly developed polyimide sEEG electrodes can be implanted as accurately as similar devices in the marker without user errors when following the IFU in a simulated clinical environment. The human cadaver ex-vivo test system provided a realistic test system, owing to the size, anatomy and similarity of tissue composition to that of the live human brain.
Collapse
Affiliation(s)
- Aura Kullmann
- NeuroOne Medical Technologies, Eden Prairie, MN, United States
| | | | | | - Robert A. McGovern
- Department of Neurosurgery, University of Minnesota Medical Center, Minneapolis, MN, United States
| | - W. Richard Marsh
- Department of Neurosurgery, Mayo Clinic, Rochester, MN, United States
| | - Debra Kridner
- NeuroOne Medical Technologies, Eden Prairie, MN, United States
| | | | - Michael C. Park
- Department of Neurosurgery, University of Minnesota Medical Center, Minneapolis, MN, United States
- Department of Neurology, University of Minnesota Medical Center, Minneapolis, MN, United States
| |
Collapse
|
13
|
Han CL, Chou CC, Chen HH, Chen YH, Lin CF, Chen C, Yu HY, Chen YW, Lee CC. Frame-based versus robot-assisted stereo-electro-encephalography for drug-resistant epilepsy. Acta Neurochir (Wien) 2024; 166:85. [PMID: 38361129 DOI: 10.1007/s00701-024-05983-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 01/11/2024] [Indexed: 02/17/2024]
Abstract
BACKGROUND Stereoelectroencephalography (SEEG) is an effective presurgical invasive evaluation for drug-resistant epilepsies. The introduction of robotic devices provides a simplified, accurate, and safe alternative to the conventional SEEG technique. We report our institutional experience with robot-assisted SEEG and compare its in vivo accuracy, operation efficiency, and safety with the more traditional SEEG workflow. METHODS All patients with medically refractory focal epilepsy who underwent SEEG depth electrode implantation between 2014 and 2022 were included in this study. Technical advancements of the robot-assisted technique are described. Analyses of patient demographics, electrode implantation accuracy, operation time, and procedure-related complications were performed. RESULTS One hundred and sixty-six patients underwent 167 SEEG procedures. The first 141 procedures were performed using a conventional approach involving a Leksell stereotactic system, and the last 26 procedures were robot-assisted. Among the 1726 depth electrodes that were inserted, the median entry point localization error was as follows: conventional (1.0 mm; range, 0.1-33.5 mm) and robot-assisted (1.1 mm; range, 0-4.8 mm) (P = 0.17). The median target point localization error was as follows: conventional (2.8 mm; range, 0.1-49 mm) and robot-assisted (1.8 mm; range, 0-30.3 mm) (P < 0.001). The median operation time was significantly reduced with the robot-assisted workflow (90 min vs. 77.5 min; P < 0.01). Total complication rates were as follows: conventional (17.7%) and robot-assisted (11.5%) (P = 0.57). Major complication rates were 3.5% and 7.7% (P = 0.77), respectively. CONCLUSIONS SEEG is a safe and highly accurate method that provides essential guidance for epilepsy surgery. Implementing SEEG in conjunction with multimodal planning systems and robotic devices can further increase safety margin, surgical efficiency, and accuracy.
Collapse
Affiliation(s)
- Chang-Lin Han
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Chien-Chen Chou
- Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Hsin-Hung Chen
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Yi-Hsiu Chen
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Chun-Fu Lin
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chien Chen
- Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Hsiang-Yu Yu
- Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Yu-Wei Chen
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Cheng-Chia Lee
- Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan.
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
- Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan.
| |
Collapse
|
14
|
Kaewborisutsakul A, Chernov M, Yokosako S, Kubota Y. Usefulness of Robotic Stereotactic Assistance (ROSA ®) Device for Stereoelectroencephalography Electrode Implantation: A Systematic Review and Meta-analysis. Neurol Med Chir (Tokyo) 2024; 64:71-86. [PMID: 38220166 PMCID: PMC10918457 DOI: 10.2176/jns-nmc.2023-0119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 10/17/2023] [Indexed: 01/16/2024] Open
Abstract
The aim of this study was to systematically review and meta-analyze the efficiency and safety of using the Robotic Stereotactic Assistance (ROSA®) device (Zimmer Biomet; Warsaw, IN, USA) for stereoelectroencephalography (SEEG) electrode implantation in patients with drug-resistant epilepsy. Based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a literature search was carried out. Overall, 855 nonduplicate relevant articles were determined, and 15 of them were selected for analysis. The benefits of the ROSA® device use in terms of electrode placement accuracy, as well as operative time length, perioperative complications, and seizure outcomes, were evaluated. Studies that were included reported on a total of 11,257 SEEG electrode implantations. The limited number of comparative studies hindered the comprehensive evaluation of the electrode implantation accuracy. Compared with frame-based or navigation-assisted techniques, ROSA®-assisted SEEG electrode implantation provided significant benefits for reduction of both overall operative time (mean difference [MD], -63.45 min; 95% confidence interval [CI] from -88.73 to -38.17 min; P < 0.00001) and operative time per implanted electrode (MD, -8.79 min; 95% CI from -14.37 to -3.21 min; P = 0.002). No significant differences existed in perioperative complications and seizure outcomes after the application of the ROSA® device and other techniques for electrode implantation. To conclude, the available evidence shows that the ROSA® device is an effective and safe surgical tool for trajectory-guided SEEG electrode implantation in patients with drug-resistant epilepsy, offering benefits for saving operative time and neither increasing the risk of perioperative complications nor negatively impacting seizure outcomes.
Collapse
Affiliation(s)
- Anukoon Kaewborisutsakul
- Neurological Surgery Unit, Division of Surgery, Faculty of Medicine, Prince of Songkla University
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| | - Mikhail Chernov
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| | - Suguru Yokosako
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| | - Yuichi Kubota
- Department of Neurosurgery, Tokyo Women's Medical University Adachi Medical Center
| |
Collapse
|
15
|
Sickler RW, Chandran AS, Funke ME, Mosher JC, Kommuru IM, Lankford J, Varnado SS, Von Allmen G, Watkins MW, Bonfante EE, Samant R, Kamali A, Miller BA, Shah MN. Comparison of 2 Robotic Systems for Pediatric Stereoelectroencephalography Implantation. World Neurosurg 2024; 182:e486-e492. [PMID: 38042289 DOI: 10.1016/j.wneu.2023.11.125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 11/24/2023] [Accepted: 11/25/2023] [Indexed: 12/04/2023]
Abstract
BACKGROUND Stereoelectroencephalography (SEEG) remains critical in guiding epilepsy surgery. Robot-assisted techniques have shown promise in improving SEEG implantation outcomes but have not been directly compared. In this single-institution series, we compared ROSA and Stealth AutoGuide robots in pediatric SEEG implantation. METHODS We retrospectively reviewed 21 sequential pediatric SEEG implantations consisting of 6 ROSA and 15 AutoGuide procedures. We determined mean operative time, time per electrode, root mean square (RMS) registration error, and surgical complications. Three-dimensional radial distances were calculated between each electrode's measured entry and target points with respective errors from the planned trajectory line. RESULTS Mean overall/per electrode operating time was 73.5/7.5 minutes for ROSA and 126.1/10.9 minutes for AutoGuide (P = 0.030 overall, P = 0.082 per electrode). Mean RMS registration error was 0.77 mm (0.55-0.93 mm) for ROSA and 0.6 mm (0.2-1.0 mm) for AutoGuide (P = 0.26). No procedures experienced complications. The mean radial (entry point error was 1.23 ± 0.11 mm for ROSA and 2.65 ± 0.12 mm for AutoGuide (P < 0.001), while the mean radial target point error was 1.86 ± 0.15 mm for ROSA and 3.25 ± 0.16 mm for AutoGuide (P < 0.001). CONCLUSIONS Overall operative time was greater for AutoGuide procedures, although there was no statistically significant difference in time per electrode. Both systems are highly accurate with no significant RMS error difference. While the ROSA robot yielded significantly lower entry and target point errors, both robots are safe and reliable for deep electrode insertion in pediatric epilepsy.
Collapse
Affiliation(s)
- Robert W Sickler
- Department of Pediatric Surgery, Division of Pediatric Neurosurgery, McGovern Medical School, Houston, Texas, USA
| | - Arjun S Chandran
- Department of Pediatric Surgery, Division of Pediatric Neurosurgery, McGovern Medical School, Houston, Texas, USA.
| | - Michael E Funke
- Department of Pediatrics, Division of Child Neurology, McGovern Medical School, Houston, Texas, USA; Department of Neurology, McGovern Medical School, Houston, Texas, USA
| | - John C Mosher
- Department of Neurology, McGovern Medical School, Houston, Texas, USA
| | - Indira M Kommuru
- Department of Pediatrics, Division of Child Neurology, McGovern Medical School, Houston, Texas, USA
| | - Jeremy Lankford
- Department of Pediatrics, Division of Child Neurology, McGovern Medical School, Houston, Texas, USA
| | - Shelley S Varnado
- Department of Pediatrics, Division of Child Neurology, McGovern Medical School, Houston, Texas, USA
| | - Gretchen Von Allmen
- Department of Pediatrics, Division of Child Neurology, McGovern Medical School, Houston, Texas, USA
| | - Michael W Watkins
- Department of Pediatrics, Division of Child Neurology, McGovern Medical School, Houston, Texas, USA
| | - Eliana E Bonfante
- Department of Radiology, McGovern Medical School, Houston, Texas, USA
| | - Rohan Samant
- Department of Neurology, McGovern Medical School, Houston, Texas, USA
| | - Arash Kamali
- Department of Neurology, McGovern Medical School, Houston, Texas, USA
| | - Brandon A Miller
- Department of Pediatric Surgery, Division of Pediatric Neurosurgery, McGovern Medical School, Houston, Texas, USA
| | - Manish N Shah
- Department of Pediatric Surgery, Division of Pediatric Neurosurgery, McGovern Medical School, Houston, Texas, USA
| |
Collapse
|
16
|
Bratu IF, Makhalova J, Garnier E, Villalon SM, Jegou A, Bonini F, Lagarde S, Pizzo F, Trébuchon A, Scavarda D, Carron R, Bénar C, Bartolomei F. Permutation entropy-derived parameters to estimate the epileptogenic zone network. Epilepsia 2024; 65:389-401. [PMID: 38041564 DOI: 10.1111/epi.17849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 11/30/2023] [Accepted: 11/30/2023] [Indexed: 12/03/2023]
Abstract
OBJECTIVE Quantification of the epileptogenic zone network (EZN) most frequently implies analysis of seizure onset. However, important information can also be obtained from the postictal period, characterized by prominent changes in the EZN. We used permutation entropy (PE), a measure of signal complexity, to analyze the peri-ictal stereoelectroencephalography (SEEG) signal changes with emphasis on the postictal state. We sought to determine the best PE-derived parameter (PEDP) for identifying the EZN. METHODS Several PEDPs were computed retrospectively on SEEG-recorded seizures of 86 patients operated on for drug-resistant epilepsy: mean baseline preictal entropy, minimum ictal entropy, maximum postictal entropy, the ratio between the maximum postictal and the minimum ictal entropy, and the ratio between the maximum postictal and the baseline preictal entropy. The performance of each biomarker was assessed by comparing the identified epileptogenic contacts or brain regions against the EZN defined by clinical analysis incorporating the Epileptogenicity Index and the connectivity epileptogenicity index methods (EZNc), using the receiver-operating characteristic and precision-recall. RESULTS The ratio between the maximum postictal and the minimum ictal entropy (defined as the Permutation Entropy Index [PEI]) proved to be the best-performing PEDP to identify the EZNC . It demonstrated the highest area under the curve (AUC) and F1 score at the contact level (AUC 0.72; F1 0.39) and at the region level (AUC 0.78; F1 0.47). PEI values gradually decreased between the EZN, the propagation network, and the non-involved regions. PEI showed higher performance in patients with slow seizure-onset patterns than in those with fast seizure-onset patterns. The percentage of resected epileptogenic regions defined by PEI was significantly correlated with surgical outcome. SIGNIFICANCE PEI is a promising tool to improve the delineation of the EZN. PEI combines ease and robustness in a routine clinical setting with high sensitivity for seizures without fast activity at seizure onset.
Collapse
Affiliation(s)
- Ionuț-Flavius Bratu
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Julia Makhalova
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
- APHM, Timone Hospital, CEMEREM, Marseille, France
| | - Elodie Garnier
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Samuel Medina Villalon
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Aude Jegou
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Francesca Bonini
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Stanislas Lagarde
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Francesca Pizzo
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Agnès Trébuchon
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Didier Scavarda
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- APHM Paediatric Neurosurgery Department, Marseille, France
| | - Romain Carron
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- APHM Functional Neurosurgery Department, Marseille, France
| | - Christian Bénar
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| | - Fabrice Bartolomei
- APHM, Timone Hospital, Epileptology and Cerebral Rhythmology, Marseille, France
- Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, Marseille, France
| |
Collapse
|
17
|
Niznik T, Grossen A, Shi H, Stephens M, Herren C, Desai VR. Learning Curve in Robotic Stereoelectroencephalography: Single Platform Experience. World Neurosurg 2024; 182:e442-e452. [PMID: 38030071 DOI: 10.1016/j.wneu.2023.11.119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 11/22/2023] [Accepted: 11/23/2023] [Indexed: 12/01/2023]
Abstract
BACKGROUND Learning curve, training, and cost impede widespread implementation of new technology. Neurosurgical robotic technology introduces challenges to visuospatial reasoning and requires the acquisition of new fine motor skills. Studies detailing operative workflow, learning curve, and patient outcomes are needed to describe the utility and cost-effectiveness of new robotic technology. METHODS A retrospective analysis was performed of pediatric patients who underwent robotic stereoelectroencephalography (sEEG) with the Medtronic Stealth Autoguide. Workflow, total operative time, and time per electrode were evaluated alongside target accuracy assessed via error measurements and root sum square. Patient demographics and clinical outcomes related to sEEG were also assessed. RESULTS Robot-assisted sEEG was performed in 12 pediatric patients. Comparison of cases over time demonstrated a mean operative time of 363.3 ± 109.5 minutes for the first 6 cases and 256.3 ± 59.1 minutes for the second 6 cases, with reduced operative time per electrode (P = 0.037). Mean entry point error, target point error, and depth point error were 1.82 ± 0.77 mm, 2.26 ± 0.71 mm, and 1.27 ± 0.53 mm, respectively, with mean root sum square of 3.23 ± 0.97 mm. Error measurements between magnetic resonance imaging and computed tomography angiography found computed tomography angiography to be more accurate with significant differences in mean entry point error (P = 0.043) and mean target point error (P = 0.035). The epileptogenic zone was identified in 11 patients, with therapeutic surgeries following in 9 patients, of whom 78% achieved an Engel class I. CONCLUSIONS This study demonstrated institutional workflow evolution and learning curve for the Autoguide in pediatric sEEG, resulting in reduced operative times and increased accuracy over a small number of cases. The platform may seamlessly and quickly be incorporated into clinical practice, and the provided workflow can facilitate a smooth transition.
Collapse
Affiliation(s)
- Taylor Niznik
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Audrey Grossen
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Helen Shi
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Mark Stephens
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Cherie Herren
- Department of Neurology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA
| | - Virendra R Desai
- Department of Neurosurgery, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA; Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA.
| |
Collapse
|
18
|
Winter F, Krueger MT, Delev D, Theys T, Van Roost DMP, Fountas K, Schijns OE, Roessler K. Current state of the art of traditional and minimal invasive epilepsy surgery approaches. BRAIN & SPINE 2024; 4:102755. [PMID: 38510599 PMCID: PMC10951767 DOI: 10.1016/j.bas.2024.102755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 01/11/2024] [Accepted: 01/21/2024] [Indexed: 03/22/2024]
Abstract
Introduction Open resective surgery remains the main treatment modality for refractory epilepsy, but is often considered a last resort option due to its invasiveness. Research question This manuscript aims to provide an overview on traditional as well as minimally invasive surgical approaches in modern state of the art epilepsy surgery. Materials and methods This narrative review addresses both historical and contemporary as well as minimal invasive surgical approaches in epilepsy surgery. Peer-reviewed published articles were retrieved from PubMed and Scopus. Only articles written in English were considered for this work. A range of traditional and minimally invasive surgical approaches in epilepsy surgery were examined, and their respective advantages and disadvantages have been summarized. Results The following approaches and techniques are discussed: minimally invasive diagnostics in epilepsy surgery, anterior temporal lobectomy, functional temporal lobectomy, selective amygdalohippocampectomy through a transsylvian, transcortical, or subtemporal approach, insulo-opercular corticectomies compared to laser interstitial thermal therapy, radiofrequency thermocoagulation, stereotactic radiosurgery, neuromodulation, high intensity focused ultrasound, and disconnection surgery including callosotomy, hemispherotomy, and subpial transections. Discussion and conclusion Understanding the benefits and disadvantages of different surgical approaches and strategies in traditional and minimal invasive epilepsy surgery might improve the surgical decision tree, as not all procedures are appropriate for all patients.
Collapse
Affiliation(s)
- Fabian Winter
- Department of Neurosurgery, Medical University of Vienna, Austria
| | - Marie T. Krueger
- Department of Clinical and Movement Neurosciences, UCL Queen Square Institute of Neurology, The National Hospital for Neurology and Neurosurgery, London, UK
- Department of Stereotactic and Functional Neurosurgery, Medical Center of the University of Freiburg, Freiburg, Germany
| | - Daniel Delev
- Department of Neurosurgery, Faculty of Medicine, RWTH Aachen University, Aachen, Germany
- Center for Integrated Oncology, Universities Aachen, Bonn, Cologne, Düsseldorf (CIO ABCD), Germany
| | - Tom Theys
- Department of Neurosurgery, Universitair Ziekenhuis Leuven, UZ Leuven, Belgium
| | | | - Kostas Fountas
- Department of Neurosurgery, University of Thessaly, Greece
| | - Olaf E.M.G. Schijns
- Department of Neurosurgery, Maastricht University Medical Center, Maastricht, the Netherlands
- School for Mental Health and Neuroscience (MHeNS), University Maastricht, Maastricht, the Netherlands
- Academic Center for Epileptology, Maastricht University Medical Center & Kempenhaeghe, Maastricht, Heeze, the Netherlands
| | - Karl Roessler
- Department of Neurosurgery, Medical University of Vienna, Austria
| |
Collapse
|
19
|
Mutoh M, Maesawa S, Nakatsubo D, Ishizaki T, Tanei T, Torii J, Ito Y, Hashida M, Saito R. Boltless nylon-suture technique for stereotactic electroencephalography as a safe, effective alternative when the anchor bolt is inappropriate. Acta Neurochir (Wien) 2024; 166:18. [PMID: 38231293 DOI: 10.1007/s00701-024-05889-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 11/23/2023] [Indexed: 01/18/2024]
Abstract
BACKGROUND The use of anchor bolts to secure electrodes to the skull can be difficult in some clinical situations. Herein, we present the boltless technique to secure electrodes to the scalp using nylon sutures to overcome the problems associated with anchor bolts. We investigated the safety, accuracy errors, and patient-related and operative factors affecting errors in the boltless technique. METHODS This single-institution retrospective series analyzed 103 electrodes placed in 12 patients. The target-point localization error (TPLE), entry-point localization error (EPLE), radial error (RE), and depth error (DE) of the electrodes were calculated. RESULTS The median of the mean operative time per electrode was 9.3 min. The median TPLE, EPLE, RE, and absolute DE value were 4.1 mm, 1.6 mm, 2.7 mm, and 1.9 mm, respectively. Positive correlations were observed between the preoperative scalp thickness, mean operative time per electrode, EPLE, RE, and the absolute value of DE versus TPLE (r = .228, p = .02; r = .678, p = .015; r = .228, p = .02; r = .445, p < .01; r = .630, p < .01, respectively), and electrode approach angle versus EPLE (r = .213, p = .031). Multivariate analysis revealed that the absolute value of DE had the strongest influence on the TPLE, followed by RE and preoperative scalp thickness, respectively (β = .938, .544, .060, respectively, p < .001). No complications related to SEEG insertion and monitoring were encountered. CONCLUSION The boltless technique using our unique planning and technical method is a safe, effective, and low-cost alternative in cases where anchor bolts are contraindicated.
Collapse
Affiliation(s)
- Manabu Mutoh
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
| | - Satoshi Maesawa
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan.
- Brain and Mind Research Center, Nagoya University, Nagoya, Aichi, Japan.
| | - Daisuke Nakatsubo
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
- Focused Ultrasound Therapy Center, Nagoya Kyoritsu Hospital, Nagoya, Aichi, Japan
| | - Tomotaka Ishizaki
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
| | - Takafumi Tanei
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
| | - Jun Torii
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
| | - Yoshiki Ito
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
| | - Miki Hashida
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
| | - Ryuta Saito
- Department of Neurosurgery, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi, 4668650, Japan
| |
Collapse
|
20
|
van den Boom MA, Gregg NM, Valencia GO, Lundstrom BN, Miller KJ, van Blooijs D, Huiskamp GJ, Leijten FS, Worrell GA, Hermes D. ER-detect: a pipeline for robust detection of early evoked responses in BIDS-iEEG electrical stimulation data. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.01.09.574915. [PMID: 38260687 PMCID: PMC10802406 DOI: 10.1101/2024.01.09.574915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2024]
Abstract
Human brain connectivity can be measured in different ways. Intracranial EEG (iEEG) measurements during single pulse electrical stimulation provide a unique way to assess the spread of electrical information with millisecond precision. To provide a robust workflow to process these cortico-cortical evoked potential (CCEP) data and detect early evoked responses in a fully automated and reproducible fashion, we developed Early Response (ER)-detect. ER-detect is an open-source Python package and Docker application to preprocess BIDS structured iEEG data and detect early evoked CCEP responses. ER-detect can use three response detection methods, which were validated against 14-manually annotated CCEP datasets from two different sites by four independent raters. Results showed that ER-detect's automated detection performed on par with the inter-rater reliability (Cohen's Kappa of ~0.6). Moreover, ER-detect was optimized for processing large CCEP datasets, to be used in conjunction with other connectomic investigations. ER-detect provides a highly efficient standardized workflow such that iEEG-BIDS data can be processed in a consistent manner and enhance the reproducibility of CCEP based connectivity results.
Collapse
Affiliation(s)
- Max A. van den Boom
- Department of Physiology and Biomedical Engineering, Mayo Clinic; Rochester, MN, USA
- Department of Neurosurgery, Mayo Clinic; Rochester, MN, USA
| | | | | | | | - Kai J. Miller
- Department of Neurosurgery, Mayo Clinic; Rochester, MN, USA
| | - Dorien van Blooijs
- Department of Neurology and Neurosurgery, UMC Utrecht Brain Center, University Medical Center Utrecht; Utrecht, NL
- Stichting Epilepsie Instellingen Nederland (SEIN); Zwolle, The Netherlands
| | - Geertjan J.M. Huiskamp
- Department of Neurology and Neurosurgery, UMC Utrecht Brain Center, University Medical Center Utrecht; Utrecht, NL
| | - Frans S.S. Leijten
- Department of Neurology and Neurosurgery, UMC Utrecht Brain Center, University Medical Center Utrecht; Utrecht, NL
| | - Gregory A. Worrell
- Department of Physiology and Biomedical Engineering, Mayo Clinic; Rochester, MN, USA
- Department of Neurology, Mayo Clinic, Rochester, MN; USA
| | - Dora Hermes
- Department of Physiology and Biomedical Engineering, Mayo Clinic; Rochester, MN, USA
| |
Collapse
|
21
|
Liu Q, Lin Z, Shen Y, Zhu J, Song J, Zhang C, Lu Y, Xu J. Use of Compressed Sensing Accelerated, Low-Velocity Encoded, Isotropic Resolution, Phase Contrast Magnetic Resonance Angiography for SEEG Electrode Implantation. World Neurosurg 2024; 181:e18-e28. [PMID: 36791880 DOI: 10.1016/j.wneu.2023.02.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 02/05/2023] [Accepted: 02/06/2023] [Indexed: 02/15/2023]
Abstract
OBJECTIVE We assessed the feasibility of using compressed sensing accelerated, low-velocity encoded, isotropic resolution phase contrast (CLIP) magnetic resonance angiography (MRA) for avascular trajectory planning of stereoelectroencephalography. METHODS Ten healthy subjects (1 woman and 9 men; age, 33.6 ± 9.0 years) and 20 consecutive patients (12 female patients; age, 22 ± 13.6 years) were enrolled in the present study. The healthy subjects underwent CLIP-MRA, and 3 other phase contrast MRA protocols with conventional parallel imaging (PI) acceleration, including low resolution with twofold PI (PI2), high resolution (HR) with fivefold PI (PI5), and HR-PI2. The patients underwent CLIP-MRA and computed tomography angiography (CTA). The image qualities were evaluated. The numbers and locations of trajectory-vessel conflict detected using CLIP-MRA were noted. RESULTS With similar scan durations, CLIP-MRA achieved higher spatial resolution compared with low resolution with PI2 and detected significantly more branches compared with HR-PI5. With the same spatial resolution, the signal/noise and contrast/noise ratios of CLIP-MRA were higher than those with HR-PI2 with a shorter scan duration. For the 12 adult patients (10 female patients; 28.8 ± 12.7 years), CLIP-MRA had better signal/noise and contrast/noise ratios than CTA. The trajectory had required modification for 14 of the 20 patients (70%), with a proportion of trajectory modification of 10.7% (23 of 215 electrodes). The middle meningeal artery, cortical vessel, and skull vessel were the main vessels with conflict (n = 11, n = 7, and n = 5, respectively). CONCLUSIONS In the present study, CLIP-MRA provided a clear cortical vascular display noninvasively without intravascular contrast and radiation. The middle meningeal artery and diploic and emissary veins were the main conflict vessels and could be clearly displayed using CLIP-MRA but not CTA.
Collapse
Affiliation(s)
- Qiangqiang Liu
- Clinical Neuroscience Center Comprehensive Epilepsy Unit, Department of Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China; Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Zengping Lin
- United Imaging Healthcare Group, Shanghai, People's Republic of China
| | - Yiwen Shen
- Department of Radiology, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Jiachen Zhu
- United Imaging Healthcare Group, Shanghai, People's Republic of China
| | - Jian Song
- Wuhan United Imaging Healthcare Surgical Technology Co., Ltd., Wuhan, People's Republic of China
| | - Chencheng Zhang
- Department of Neurosurgery, Center for Functional Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Yong Lu
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Jiwen Xu
- Clinical Neuroscience Center Comprehensive Epilepsy Unit, Department of Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China; Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
| |
Collapse
|
22
|
Brimley C, Shimony N. Accuracy and Utility of Frameless Stereotactic Placement of Stereoelectroencephalography Electrodes. World Neurosurg 2023; 180:e226-e232. [PMID: 37739177 DOI: 10.1016/j.wneu.2023.09.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 09/10/2023] [Accepted: 09/11/2023] [Indexed: 09/24/2023]
Abstract
BACKGROUND Successful surgery for epilepsy hinges on identification of the epileptogenic focus. Stereoelectroencephalography (sEEG) is the most effective way to identify most seizure foci. There are multiple methods of inserting depth electrodes, including frame-based, frameless, and robot-assisted techniques. Studies have shown the accuracy of frame-based and robotic-assisted techniques to be statistically similar, while only one study has detailed the frameless sEEG insertion technique. METHODS Patients underwent placement of sEEG depth electrodes using frameless stereotaxy from September 2019 to September 2021 at Geisinger Medical Center by a single surgeon. Seizure history, electrode placement accuracy relative to the planned trajectories, surgical times, success rate of identifying the epileptogenic focus, and subsequent seizure control rates after surgical treatment were documented. RESULTS Data were available for 21 patients and 181 electrodes inserted using the VarioGuide frameless stereotactic system. Each insertion took an average of 14.5 minutes per lead. Average entry variance was 2.7 mm with an average target variance of 4.6 mm. The epileptogenic focus was identified in 19 of 21 patients, and further surgical treatment was performed in 18 of 21 patients (85.7%). CONCLUSIONS VarioGuide frameless stereotaxy for sEEG placement is comparable to frame-based and robotic-assisted techniques with statistically similar rates of epileptic focus identification. Lead placement accuracy is slightly lower and time per lead is slightly higher relative to robot-assisted surgeries. When a robot system is unavailable, surgeons can consider using a frameless stereotactic technique for sEEG insertion, allowing patients to benefit from a similarly high rate of epileptic zone identification.
Collapse
Affiliation(s)
- Cameron Brimley
- Geisinger Neuroscience Institute, Geisinger Commonwealth School of Medicine, Danville, Pennsylvania, USA; Department of Surgery, St. Jude Children's Research Hospital, Memphis, Tennessee, USA; Le Bonheur Neuroscience Institute, Le Bonheur Children's Hospital, Memphis, Tennessee, USA; Department of Neurosurgery, University of Tennessee Health Science Center/Semmes-Murphey Clinic, Memphis, Tennessee, USA.
| | - Nir Shimony
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA; Department of Surgery, St. Jude Children's Research Hospital, Memphis, Tennessee, USA; Le Bonheur Neuroscience Institute, Le Bonheur Children's Hospital, Memphis, Tennessee, USA; Department of Neurosurgery, University of Tennessee Health Science Center/Semmes-Murphey Clinic, Memphis, Tennessee, USA
| |
Collapse
|
23
|
Liu X, Zhang Q, Li J, Xu Q, Zhuo Z, Li J, Zhou X, Lu M, Zhou Q, Pan H, Wu N, Zhou Q, Shi F, Lu G, Liu Y, Zhang Z. Coordinatized lesion location analysis empowering ROI-based radiomics diagnosis on brain gliomas. Eur Radiol 2023; 33:8776-8787. [PMID: 37382614 DOI: 10.1007/s00330-023-09871-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 05/09/2023] [Accepted: 05/16/2023] [Indexed: 06/30/2023]
Abstract
OBJECTIVES To assess the value of coordinatized lesion location analysis (CLLA), in empowering ROI-based imaging diagnosis of gliomas by improving accuracy and generalization performances. METHODS In this retrospective study, pre-operative contrasted T1-weighted and T2-weighted MR images were obtained from patients with gliomas from three centers: Jinling Hospital, Tiantan Hospital, and the Cancer Genome Atlas Program. Based on CLLA and ROI-based radiomic analyses, a fusion location-radiomics model was constructed to predict tumor grades, isocitrate dehydrogenase (IDH) status, and overall survival (OS). An inter-site cross-validation strategy was used for assessing the performances of the fusion model on accuracy and generalization with the value of area under the curve (AUC) and delta accuracy (ACC) (ACCtesting-ACCtraining). Comparisons of diagnostic performances were performed between the fusion model and the other two models constructed with location and radiomics analysis using DeLong's test and Wilcoxon signed ranks test. RESULTS A total of 679 patients (mean age, 50 years ± 14 [standard deviation]; 388 men) were enrolled. Based on tumor location probabilistic maps, fusion location-radiomics models (averaged AUC values of grade/IDH/OS: 0.756/0.748/0.768) showed the highest accuracy in contrast to radiomics models (0.731/0.686/0.716) and location models (0.706/0.712/0.740). Notably, fusion models ([median Delta ACC: - 0.125, interquartile range: 0.130]) demonstrated improved generalization than that of radiomics model ([- 0.200, 0.195], p = 0.018). CONCLUSIONS CLLA could empower ROI-based radiomics diagnosis of gliomas by improving the accuracy and generalization of the models. CLINICAL RELEVANCE STATEMENT This study proposed a coordinatized lesion location analysis for glioma diagnosis, which could improve the performances of the conventional ROI-based radiomics model in accuracy and generalization. KEY POINTS • Using coordinatized lesion location analysis, we mapped anatomic distribution patterns of gliomas with specific pathological and clinical features and constructed glioma prediction models. • We integrated coordinatized lesion location analysis into ROI-based analysis of radiomics to propose new fusion location-radiomics models. • Fusion location-radiomics models, with the advantages of being less influenced by variabilities, improved accuracy, and generalization performances of ROI-based radiomics models on predicting the diagnosis of gliomas.
Collapse
Affiliation(s)
- Xiaoxue Liu
- Department of Diagnostic Radiology, Affiliated Jinling Hospital, Medical School of Nanjing University, 305#, Eastern Zhongshan Rd, Nanjing, 210002, China
| | - Qirui Zhang
- Department of Diagnostic Radiology, Affiliated Jinling Hospital, Medical School of Nanjing University, 305#, Eastern Zhongshan Rd, Nanjing, 210002, China
| | - Jianrui Li
- Department of Diagnostic Radiology, Affiliated Jinling Hospital, Medical School of Nanjing University, 305#, Eastern Zhongshan Rd, Nanjing, 210002, China
| | - Qiang Xu
- Department of Diagnostic Radiology, Affiliated Jinling Hospital, Medical School of Nanjing University, 305#, Eastern Zhongshan Rd, Nanjing, 210002, China
| | - Zhizheng Zhuo
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China
| | - Junjie Li
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China
| | - Xian Zhou
- Department of Diagnostic Radiology, Affiliated Jinling Hospital, Medical School of Nanjing University, 305#, Eastern Zhongshan Rd, Nanjing, 210002, China
| | - Mengjie Lu
- School of Public Health, Shanghai JiaoTong University School of Medicine, Shanghai, 200240, China
| | - Qingqing Zhou
- Department of Radiology, The Affiliated Jiangning Hospital of Nanjing Medical University, Nanjing, 211100, China
| | - Hao Pan
- Department of Neurosurgery, Affiliated Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, China
| | - Nan Wu
- Department of Pathology, Affiliated Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, China
| | - Qing Zhou
- Department of Research and Development, Shanghai United Imaging Intelligence Co., Ltd., Shanghai, 200232, China
| | - Feng Shi
- Department of Research and Development, Shanghai United Imaging Intelligence Co., Ltd., Shanghai, 200232, China
| | - Guangming Lu
- Department of Diagnostic Radiology, Affiliated Jinling Hospital, Medical School of Nanjing University, 305#, Eastern Zhongshan Rd, Nanjing, 210002, China
- State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, 210093, China
| | - Yaou Liu
- Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China
| | - Zhiqiang Zhang
- Department of Diagnostic Radiology, Affiliated Jinling Hospital, Medical School of Nanjing University, 305#, Eastern Zhongshan Rd, Nanjing, 210002, China.
- State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, 210093, China.
| |
Collapse
|
24
|
Wang SH, Siebenhühner F, Arnulfo G, Myrov V, Nobili L, Breakspear M, Palva S, Palva JM. Critical-like Brain Dynamics in a Continuum from Second- to First-Order Phase Transition. J Neurosci 2023; 43:7642-7656. [PMID: 37816599 PMCID: PMC10634584 DOI: 10.1523/jneurosci.1889-22.2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 06/07/2023] [Accepted: 09/25/2023] [Indexed: 10/12/2023] Open
Abstract
The classic brain criticality hypothesis postulates that the brain benefits from operating near a continuous second-order phase transition. Slow feedback regulation of neuronal activity could, however, lead to a discontinuous first-order transition and thereby bistable activity. Observations of bistability in awake brain activity have nonetheless remained scarce and its functional significance unclear. Moreover, there is no empirical evidence to support the hypothesis that the human brain could flexibly operate near either a first- or second-order phase transition despite such a continuum being common in models. Here, using computational modeling, we found bistable synchronization dynamics to emerge through elevated positive feedback and occur exclusively in a regimen of critical-like dynamics. We then assessed bistability in vivo with resting-state MEG in healthy adults (7 females, 11 males) and stereo-electroencephalography in epilepsy patients (28 females, 36 males). This analysis revealed that a large fraction of the neocortices exhibited varying degrees of bistability in neuronal oscillations from 3 to 200 Hz. In line with our modeling results, the neuronal bistability was positively correlated with classic assessment of brain criticality across narrow-band frequencies. Excessive bistability was predictive of epileptic pathophysiology in the patients, whereas moderate bistability was positively correlated with task performance in the healthy subjects. These empirical findings thus reveal the human brain as a one-of-a-kind complex system that exhibits critical-like dynamics in a continuum between continuous and discontinuous phase transitions.SIGNIFICANCE STATEMENT In the model, while synchrony per se was controlled by connectivity, increasing positive local feedback led to gradually emerging bistable synchrony with scale-free dynamics, suggesting a continuum between second- and first-order phase transitions in synchrony dynamics inside a critical-like regimen. In resting-state MEG and SEEG, bistability of ongoing neuronal oscillations was pervasive across brain areas and frequency bands and was observed only with concurring critical-like dynamics as the modeling predicted. As evidence for functional relevance, moderate bistability was positively correlated with executive functioning in the healthy subjects, and excessive bistability was associated with epileptic pathophysiology. These findings show that critical-like neuronal dynamics in vivo involves both continuous and discontinuous phase transitions in a frequency-, neuroanatomy-, and state-dependent manner.
Collapse
Affiliation(s)
- Sheng H Wang
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, 00014 Helsinki, Finland
- Doctoral Programme Brain & Mind, University of Helsinki, 00014 Helsinki, Finland
- BioMag Laboratory, HUS Medical Imaging Center, 00290 Helsinki, Finland
- Department of Neuroscience and Biomedical Engineering, Aalto University, 00076 Espoo, Finland
| | - Felix Siebenhühner
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, 00014 Helsinki, Finland
- BioMag Laboratory, HUS Medical Imaging Center, 00290 Helsinki, Finland
| | - Gabriele Arnulfo
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, 00014 Helsinki, Finland
- Department of Informatics, Bioengineering, Robotics and System Engineering, University of Genoa, 16136 Genoa, Italy
| | - Vladislav Myrov
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, 00014 Helsinki, Finland
- Department of Neuroscience and Biomedical Engineering, Aalto University, 00076 Espoo, Finland
| | - Lino Nobili
- Department of Neurosciences, Rehabilitation, Ophthalmology, Genetics and Maternal and Children's Sciences, University of Genoa, 16136 Genoa, Italy
- Child Neuropsychiatry Unit, Istituto Di Ricovero e Cura a Carattere Scientifico Istituto Giannina Gaslini, 16147 Genoa, Italy
- Centre of Epilepsy Surgery "C. Munari," Department of Neuroscience, Niguarda Hospital, 20162 Milan, Italy
| | - Michael Breakspear
- College of Engineering, Science and Environment, College of Health and Medicine, University of Newcastle, Callaghan, 2308 Australia
| | - Satu Palva
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, 00014 Helsinki, Finland
- Centre for Cognitive Neuroimaging, Institute of Neuroscience & Psychology, University of Glasgow, Glasgow G12 8QB, United Kingdom
| | - J Matias Palva
- Neuroscience Center, Helsinki Institute of Life Science, University of Helsinki, 00014 Helsinki, Finland
- Department of Neuroscience and Biomedical Engineering, Aalto University, 00076 Espoo, Finland
- Centre for Cognitive Neuroimaging, Institute of Neuroscience & Psychology, University of Glasgow, Glasgow G12 8QB, United Kingdom
| |
Collapse
|
25
|
Agashe S, Brinkmann BH, Cox BC, Wong-Kisiel L, Van Gompel JJ, Marsh RW, Miller KJ, Krecke KN, Britton JW. Implications of intracranial hemorrhage associated with stereo-EEG. Clin Neurophysiol 2023; 155:86-93. [PMID: 37806180 DOI: 10.1016/j.clinph.2023.08.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 07/27/2023] [Accepted: 08/18/2023] [Indexed: 10/10/2023]
Abstract
OBJECTIVE Intracranial hemorrhage (ICH) is a known complication during stereo-electroencephalography (sEEG) however true rates remain unknown. We provide a comprehensive review of ICH during sEEG regardless of clinical symptoms. Secondly, we analyzed sEEG recordings to identify electrographic correlates of ICH. METHODS This is a retrospective study of patients undergoing sEEG between January 2016 and April 2022 at the Mayo Clinic in Rochester. We reviewed medical records and imaging studies to identify ICH. We analyzed ICH by type, electrode trajectories, timing, sEEG findings and outcomes. RESULTS There were a total of 201 sEEG implants, of which 23 (11%) cases or 0.9% electrodes implanted had evidence of ICH. The majority of affected patients (82%) were either asymptomatic or had mild clinical neurological manifestations. In 90% of patients who proceeded with surgical treatments, outcomes were favorable. The most common sEEG finding in contacts in proximity of ICH was either focal slowing with interictal discharges or focal electrographic seizures. CONCLUSIONS ICH associated with sEEG is likely under-reported in literature. We present electroencephalographic correlates of ICH that may aid identification of ICH in the course of performing sEEG monitoring. SIGNIFICANCE Our data provides clinically relevant information on potential risks and outcomes of ICH. Furthermore, our findings aid identification of ICH during sEEG.
Collapse
Affiliation(s)
- Shruti Agashe
- Department of Neurology, Mayo Clinic, Rochester, MN, USA.
| | | | - Benjamin C Cox
- Department of Neurology, Mayo Clinic, Rochester, MN, USA
| | | | | | | | - Kai J Miller
- Department of Neurosurgery, Mayo Clinic, Rochester, MN, USA
| | - Karl N Krecke
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
26
|
Li P, Zhou Y, Zhang Q, Yang Y, Wang M, Zhu R, Li H, Gu S, Zhao R. Frameless robot-assisted stereoelectroencephalography-guided radiofrequency: methodology, results, complications and stereotactic application accuracy in pediatric hypothalamic hamartomas. Front Neurol 2023; 14:1259171. [PMID: 37928157 PMCID: PMC10621047 DOI: 10.3389/fneur.2023.1259171] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Accepted: 10/09/2023] [Indexed: 11/07/2023] Open
Abstract
Objective We aimed to investigate the methodology, results, complications and stereotactic application accuracy of electrode implantation and its explanatory variables in stereoelectroencephalography-guided radiofrequency thermocoagulation (SEEG-RFTC) for pediatric hypothalamic hamartoma. Methods Children with hypothalamic hamartoma who underwent robot-assisted SEEG-RFTC between December 2017 and November 2021 were retrospectively analyzed. The methodology, seizure outcome, complications, in vivo accuracy of electrode implantation and its explanatory variables were analyzed. Results A total of 161 electrodes were implanted in 28 patients with 30 surgeries. Nine electrodes not following the planned trajectories due to intraoperative replanning were excluded, and the entry point and target point errors of 152 electrodes were statistically analyzed. The median entry point error was 0.87 mm (interquartile range, 0.50-1.41 mm), and the median target point error was 2.74 mm (interquartile range, 2.01-3.63 mm). Multifactor analysis showed that whether the electrode was bent (b = 2.16, p < 0.001), the length of the intracranial electrode (b = 0.02, p = 0.049), and the entry point error (b = 0.337, p = 0.017) had statistically significant effects on the target error. During follow-up (mean duration 31 months), 27 of 30 (90%) procedures were seizure-free. The implantation-related complication rate was 2.6% (4/152), and the major complication rate in all procedures was 6.7% (2/30). Conclusion Robot-assisted SEEG-RFTC is a safe, effective and accurate procedure for pediatric hypothalamic hamartoma. Explanatory variables significantly associated with the target point localization error at multivariate analysis include whether the intracranial electrode is bent, the intracranial electrode length and the entry point error.
Collapse
Affiliation(s)
- Ping Li
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
| | - Yuanfeng Zhou
- Department of Neurology, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Qin Zhang
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
| | - Yuantao Yang
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
| | - Min Wang
- Department of Neurosurgery, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Renqing Zhu
- Department of Neurosurgery, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Hao Li
- Department of Neurosurgery, Children’s Hospital of Fudan University, National Children’s Medical Center, Shanghai, China
| | - Shuo Gu
- Department of Neurosurgery, The First Affiliated Hospital of Hainan Medical University, Haikou, China
| | - Rui Zhao
- Department of Neurosurgery, Hainan Women and Children's Medical Center, Haikou, China
- Department of Neurosurgery, Children’s Hospital of Shanghai, Shanghai, China
| |
Collapse
|
27
|
Abarrategui B, Mariani V, Rizzi M, Berta L, Scarpa P, Zauli FM, Squarza S, Banfi P, d’Orio P, Cardinale F, Del Vecchio M, Caruana F, Avanzini P, Sartori I. Language lateralization mapping (reversibly) masked by non-dominant focal epilepsy: a case report. Front Hum Neurosci 2023; 17:1254779. [PMID: 37900727 PMCID: PMC10600519 DOI: 10.3389/fnhum.2023.1254779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 09/15/2023] [Indexed: 10/31/2023] Open
Abstract
Language lateralization in patients with focal epilepsy frequently diverges from the left-lateralized pattern that prevails in healthy right-handed people, but the mechanistic explanations are still a matter of debate. Here, we debate the complex interaction between focal epilepsy, language lateralization, and functional neuroimaging techniques by introducing the case of a right-handed patient with unaware focal seizures preceded by aphasia, in whom video-EEG and PET examination suggested the presence of focal cortical dysplasia in the right superior temporal gyrus, despite a normal structural MRI. The functional MRI for language was inconclusive, and the neuropsychological evaluation showed mild deficits in language functions. A bilateral stereo-EEG was proposed confirming the right superior temporal gyrus origin of seizures, revealing how ictal aphasia emerged only once seizures propagated to the left superior temporal gyrus and confirming, by cortical mapping, the left lateralization of the posterior language region. Stereo-EEG-guided radiofrequency thermocoagulations of the (right) focal cortical dysplasia not only reduced seizure frequency but led to the normalization of the neuropsychological assessment and the "restoring" of a classical left-lateralized functional MRI pattern of language. This representative case demonstrates that epileptiform activity in the superior temporal gyrus can interfere with the functioning of the contralateral homologous cortex and its associated network. In the case of presurgical evaluation in patients with epilepsy, this interference effect must be carefully taken into consideration. The multimodal language lateralization assessment reported for this patient further suggests the sensitivity of different explorations to this interference effect. Finally, the neuropsychological and functional MRI changes after thermocoagulations provide unique cues on the network pathophysiology of focal cortical dysplasia and the role of diverse techniques in indexing language lateralization in complex scenarios.
Collapse
Affiliation(s)
- Belén Abarrategui
- “Claudio Munari” Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Department of Neurology, Hospital Universitario Puerta de Hierro, Majadahonda, Spain
| | - Valeria Mariani
- “Claudio Munari” Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Neurology and Stroke Unit, ASST Santi Paolo e Carlo, Presidio San Carlo Borromeo, Milan, Italy
| | - Michele Rizzi
- “Claudio Munari” Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Department of Neurosurgery, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
| | - Luca Berta
- Department of Medical Physics, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Pina Scarpa
- Cognitive Neuropsychology Centre, Department of Neuroscience, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Flavia Maria Zauli
- “Claudio Munari” Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Department of Biomedical and Clinical Sciences, Università degli Studi di Milano, Milan, Italy
- Department of Philosophy “P. Martinetti”, Università degli Studi di Milano, Milan, Italy
| | - Silvia Squarza
- Department of Neuroradiology, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Paola Banfi
- Neurology and Stroke Unit, ASST Sette Laghi Ospedale di Circolo, Varese, Italy
| | - Piergiorgio d’Orio
- “Claudio Munari” Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Unit of Neuroscience, Department of Medicine and Surgery, Università degli Studi di Parma, Parma, Italy
- Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy
| | - Francesco Cardinale
- “Claudio Munari” Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Unit of Neuroscience, Department of Medicine and Surgery, Università degli Studi di Parma, Parma, Italy
- Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy
| | - Maria Del Vecchio
- Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy
| | - Fausto Caruana
- Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy
| | - Pietro Avanzini
- Institute of Neuroscience, Consiglio Nazionale delle Ricerche, Parma, Italy
| | - Ivana Sartori
- “Claudio Munari” Epilepsy Surgery Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy
| |
Collapse
|
28
|
Winslow NK, Olson EA, Bach SE, Maldonado AL. Neuropathologic changes associated with stereoelectroencephalography depth electrode placement. J Neurosurg Sci 2023; 67:631-637. [PMID: 35380201 DOI: 10.23736/s0390-5616.22.05616-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The aim of this study was to detail the neuropathologic changes resulting from the surgical placement of stereoelectroencephalography (SEEG) leads in an initial small group of epilepsy cases and to raise awareness of this iatrogenic pathology, especially to those medical providers who specialize in the care of epilepsy patients. METHODS Five consecutive patients who underwent epilepsy resection surgery following SEEG monitoring at OSF Saint Francis Medical Center were included in our report. Resection specimens were examined grossly and entirely submitted for microscopic evaluation by a neuropathologist. Seizure-related pathologies, as well as histologic changes related to SEEG electrode placement, were documented. RESULTS The patient cohort included two females and three males, with an age range of 9 to 47 years. Neuropathologic examination revealed one or more seizure-related pathologies in each patient's resection specimen. In addition, all brain resection specimens showed multiple microinfarcts, which appeared to correlate with the placement and size of SEEG electrodes. Patchy leptomeningeal chronic inflammation was also seen in most cases. CONCLUSIONS SEEG electrode placement is an effective procedure for determining epileptogenic regions and guiding subsequent resection surgeries in medically refractory epilepsy. Multiple microinfarcts and chronic inflammation are commonly seen in brain resection specimens following SEEG electrode insertion, but studies detailing these iatrogenic histopathologic changes are lacking. The clinical significance and long-term implications of multiple small foci of electrode-induced injury that remain in the patient's brain after resection of the epileptogenic focus are unknown and may provide a welcome area for future study.
Collapse
Affiliation(s)
- Nolan K Winslow
- Department of Neurosurgery, OSF Saint Francis Medical Center, Peoria, IL, USA -
| | - Elsa A Olson
- College of Medicine, University of Illinois, Peoria, IL, USA
| | - Sarah E Bach
- Department of Pathology, OSF Saint Francis Medical Center, Peoria, IL, USA
| | - Andres L Maldonado
- Department of Neurosurgery, OSF Saint Francis Medical Center, Peoria, IL, USA
| |
Collapse
|
29
|
Vasconcellos FDN, Almeida T, Müller Fiedler A, Fountain H, Santos Piedade G, Monaco BA, Jagid J, Cordeiro JG. Robotic-Assisted Stereoelectroencephalography: A Systematic Review and Meta-Analysis of Safety, Outcomes, and Precision in Refractory Epilepsy Patients. Cureus 2023; 15:e47675. [PMID: 38021558 PMCID: PMC10672406 DOI: 10.7759/cureus.47675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/25/2023] [Indexed: 12/01/2023] Open
Abstract
Robotic assistance in stereoelectroencephalography (SEEG) holds promising potential for enhancing accuracy, efficiency, and safety during electrode placement and surgical procedures. This systematic review and meta-analysis, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and International Prospective Register of Systematic Reviews (PROSPERO) registration, delves into the latest advancements and implications of robotic systems in SEEG, while meticulously evaluating outcomes and safety measures. Among 855 patients suffering from medication-refractory epilepsy who underwent SEEG in 29 studies, averaging 24.6 years in age, the most prevalent robots employed were robotic surgical assistant (ROSA) (450 patients), Neuromate (207), Sinovation (140), and ISys1 (58). A total of 8,184 electrodes were successfully implanted, with an average operative time of 157.2 minutes per procedure and 15.1 minutes per electrode, resulting in an overall mean operative time of 157.7 minutes across all studies. Notably, the mean target point error (TPE) stood at 2.13 mm, the mean entry point error (EPE) at 1.48 mm, and postoperative complications occurred in 7.69% of robotically assisted (RA) SEEG cases (60), with 85% of these complications being asymptomatic. This comprehensive analysis underscores the safety and efficacy of RA-SEEG in patients with medication-refractory epilepsy, characterized by low complication rates, reduced operative time, and precise electrode placement, supporting its widespread adoption in clinical practice, with no discernible differences noted among the various robotic systems.
Collapse
Affiliation(s)
| | - Timoteo Almeida
- Department of Neurosurgery, University of Miami, Miami, USA
- Department of Radiation Oncology, University of Miami, Miami, USA
| | | | - Hayes Fountain
- Department of Neurosurgery, University of Miami, Miami, USA
| | | | - Bernardo A Monaco
- Department of Neurological Surgery, University of Miami, Miami, USA
- Department of Neurological Surgery, CDF (Clinica de Dor e Funcional), Sao Paulo, BRA
- Department of Neurological Surgery, University of Sao Paulo, Sao Paulo, BRA
| | - Jonathan Jagid
- Department of Neurological Surgery, University of Miami, Miami, USA
| | | |
Collapse
|
30
|
d'Orio P, Revay M, Bevacqua G, Battista F, Castana L, Squarza S, Chiarello D, Lo Russo G, Sartori I, Cardinale F. Stereo-electroencephalography (SEEG)-Guided Surgery in Epilepsy With Cingulate Gyrus Involvement: Electrode Implantation Strategies and Postoperative Seizure Outcome. J Clin Neurophysiol 2023; 40:516-528. [PMID: 36930225 DOI: 10.1097/wnp.0000000000001000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023] Open
Abstract
SUMMARY Surgical treatment of cingulate gyrus epilepsy is associated with good results on seizures despite its rarity and challenging aspects. Invasive EEG monitoring is often mandatory to assess the epileptogenic zone in these patients. To date, only small surgical series have been published, and a consensus about management of these complex cases did not emerge. The authors retrospectively analyzed a large surgical series of patients in whom at least part of the cingulate gyrus was confirmed as included in the epileptogenic zone by means of stereo-electroencephalography and was thus resected. One hundred twenty-seven patients were selected. Stereo-electroencephalography-guided implantation of intracerebral electrodes was performed in the right hemisphere in 62 patients (48.8%) and in the left hemisphere in 44 patients (34.7%), whereas 21 patients (16.5%) underwent bilateral implantations. The median number of implanted electrodes per patient was 13 (interquartile range 12-15). The median number of electrodes targeting the cingulate gyrus was 4 (interquartile range 3-5). The cingulate gyrus was explored bilaterally in 19 patients (15%). Complication rate was 0.8%. A favorable outcome (Engel class I) was obtained in 54.3% of patients, with a median follow-up of 60 months. The chance to obtain seizure freedom increased in cases in whom histologic diagnosis was type-IIb focal cortical dysplasia or tumor (mostly ganglioglioma or dysembryoplastic neuroepithelial tumor) and with male gender. Higher seizure frequency predicted better outcome with a trend toward significance. Our findings suggest that stereo-electroencephalography is a safe and effective methodology in achieving seizure freedom in complex cases of epilepsy with cingulate gyrus involvement.
Collapse
Affiliation(s)
- Piergiorgio d'Orio
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Department of Medicine and Surgery, Unit of Neuroscience, University of Parma, Parma, Italy
| | - Martina Revay
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Giuseppina Bevacqua
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Neurosurgery Unit, Department of Translational Medicine, Ferrara University, Ferrara, Italy
| | - Francesca Battista
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Neurosurgery Clinic, Department of Neuroscience, Psychology, Pharmacology, and Child Health, Careggi University Hospital and University of Florence, Florence, Italy; and
| | - Laura Castana
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Silvia Squarza
- Neuroradiology Department, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Daniela Chiarello
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Giorgio Lo Russo
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Ivana Sartori
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
| | - Francesco Cardinale
- "Claudio Munari" Epilepsy Surgery Centre, Azienda Socio-Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda, Milan, Italy
- Department of Medicine and Surgery, Unit of Neuroscience, University of Parma, Parma, Italy
| |
Collapse
|
31
|
Gorbachuk M, Machetanz K, Weinbrenner E, Grimm F, Wuttke TV, Wang S, Ethofer S, Tatagiba M, Rona S, Honegger J, Naros G. Robot-assisted stereoencephalography vs subdural electrodes in the evaluation of temporal lobe epilepsy. Epilepsia Open 2023; 8:888-897. [PMID: 37149851 PMCID: PMC10472365 DOI: 10.1002/epi4.12756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 04/30/2023] [Indexed: 05/09/2023] Open
Abstract
OBJECTIVE Invasive video-electroencephalography (iVEEG) is the gold standard for evaluation of refractory temporal lobe epilepsy before second stage resective surgery (SSRS). Traditionally, the presumed seizure onset zone (SOZ) has been covered with subdural electrodes (SDE), a very invasive procedure prone to complications. Temporal stereoelectroencephalography (SEEG) with conventional frame-based stereotaxy is time-consuming and impeded by the geometry of the frame. The introduction of robotic assistance promised a simplification of temporal SEEG implantation. However, the efficacy of temporal SEEG in iVEEG remains unclear. The aim of this study was therefore to describe the efficiency and efficacy of SEEG in iVEEG of temporal lobe epilepsy. METHODS This retrospective study enrolled 60 consecutive patients with medically intractable epilepsy who underwent iVEEG of a potential temporal SOZ by SDE (n = 40) or SEEG (n = 20). Surgical time efficiency was analyzed by the skin-to-skin time (STS) and the total procedure time (TPT) and compared between groups (SDE vs SEEG). Surgical risk was depicted by the 90-day complication rate. Temporal SOZ were treated by SSRS. Favorable outcome (Engel°1) was assessed after 1 year of follow-up. RESULTS Robot-assisted SEEG significantly reduced the duration of surgery (STS and TPT) compared to SDE implantations. There was no significant difference in complication rates. Notably, all surgical revisions in this study were attributed to SDE. Unilateral temporal SOZ was detected in 34/60 cases. Of the 34 patients, 30 underwent second stage SSRS. Both SDE and SEEG had a good predictive value for the outcome of temporal SSRS with no significant group difference. SIGNIFICANCE Robot-assisted SEEG improves the accessibility of the temporal lobe for iVEEG by increasing surgical time efficiency and by simplifying trajectory selection without losing its predictive value for SSRS.
Collapse
Affiliation(s)
- Mykola Gorbachuk
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Kathrin Machetanz
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Eliane Weinbrenner
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Florian Grimm
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Thomas V. Wuttke
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Sophie Wang
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Silke Ethofer
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Marcos Tatagiba
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Sabine Rona
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Jürgen Honegger
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| | - Georgios Naros
- Neurosurgical Clinic, Department of Neurosurgery and NeurotechnologyEberhard Karls UniversityTuebingenGermany
| |
Collapse
|
32
|
Williams A, Ordaz JD, Budnick H, Desai VR, Tailor Bmbch J, Raskin JS. Accuracy of Depth Electrodes is Not Time-Dependent in Robot-Assisted Stereoelectroencephalography in a Pediatric Population. Oper Neurosurg (Hagerstown) 2023; 25:269-277. [PMID: 37219595 DOI: 10.1227/ons.0000000000000764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Accepted: 03/21/2023] [Indexed: 05/24/2023] Open
Abstract
BACKGROUND AND OBJECTIVES Robot-assisted stereoelectroencephalography (sEEG) is steadily supplanting traditional frameless and frame-based modalities for minimally invasive depth electrode placement in epilepsy workup. Accuracy rates similar to gold-standard frame-based techniques have been achieved, with improved operative efficiency. Limitations in cranial fixation and placement of trajectories in pediatric patients are believed to contribute to a time-dependent accumulation of stereotactic error. Thus, we aim to study the impact of time as a marker of cumulative stereotactic error during robotic sEEG. METHODS All patients between October 2018 and June 2022 who underwent robotic sEEG were included. Radial errors at entry and target points as well as depth and Euclidean distance errors were collected for each electrode, excluding those with errors over 10 mm. Target point errors were standardized by planned trajectory length. ANOVA and error rates over time were analyzed using GraphPad Prism 9. RESULTS Forty-four patients met inclusion criteria for a total of 539 trajectories. Number of electrodes placed ranged from 6 to 22. Average root mean squared error was 0.45 ± 0.12 mm. Average entry, target, depth, and Euclidean distance errors were 1.12 ± 0.41 mm, 1.46 ± 0.44 mm, -1.06 ± 1.43 mm, and 3.01 ± 0.71 mm, respectively. There was no significant increased error with each sequential electrode placed (entry error P -value = .54, target error P -value = .13, depth error P -value = .22, Euclidean distance P -value = .27). CONCLUSION No decremental accuracy over time was observed. This may be secondary to our workflow which prioritizes oblique and longer trajectories first and then into less error-prone trajectories. Further study on the effect of level of training may reveal a novel difference in error rates.
Collapse
Affiliation(s)
- Ari Williams
- Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Josue D Ordaz
- Department of Neurological Surgery, Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Hailey Budnick
- Department of Neurological Surgery, Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Virendra R Desai
- Department of Neurosurgery, Section of Pediatric Neurosurgery, Oklahoma Children's Hospital, University of Oklahoma School of Medicine, Oklahoma City, Oklahoma, USA
| | - Jignesh Tailor Bmbch
- Department of Neurological Surgery, Section of Pediatric Neurosurgery, Riley Hospital for Children, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Jeffrey S Raskin
- Department of Neurosurgery, Section of Pediatric Neurosurgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
33
|
Fuscà M, Siebenhühner F, Wang SH, Myrov V, Arnulfo G, Nobili L, Palva JM, Palva S. Brain criticality predicts individual levels of inter-areal synchronization in human electrophysiological data. Nat Commun 2023; 14:4736. [PMID: 37550300 PMCID: PMC10406818 DOI: 10.1038/s41467-023-40056-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 07/10/2023] [Indexed: 08/09/2023] Open
Abstract
Neuronal oscillations and their synchronization between brain areas are fundamental for healthy brain function. Yet, synchronization levels exhibit large inter-individual variability that is associated with behavioral variability. We test whether individual synchronization levels are predicted by individual brain states along an extended regime of critical-like dynamics - the Griffiths phase (GP). We use computational modelling to assess how synchronization is dependent on brain criticality indexed by long-range temporal correlations (LRTCs). We analyze LRTCs and synchronization of oscillations from resting-state magnetoencephalography and stereo-electroencephalography data. Synchronization and LRTCs are both positively linearly and quadratically correlated among healthy subjects, while in epileptogenic areas they are negatively linearly correlated. These results show that variability in synchronization levels is explained by the individual position along the GP with healthy brain areas operating in its subcritical and epileptogenic areas in its supercritical side. We suggest that the GP is fundamental for brain function allowing individual variability while retaining functional advantages of criticality.
Collapse
Affiliation(s)
- Marco Fuscà
- Centre for Cognitive Neuroimaging, School of Psychology and Neuroscience, University of Glasgow, Glasgow, UK
- Neuroscience Center, HiLIFE-Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
| | - Felix Siebenhühner
- Neuroscience Center, HiLIFE-Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- BioMag Laboratory, HUS Medical Imaging Center, University of Helsinki, Aalto University, and Helsinki University Hospital, Helsinki, Finland
| | - Sheng H Wang
- Neuroscience Center, HiLIFE-Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
- CEA, NeuroSpin, Gif-sur-Yvette, France
- MIND team, Inria, Université Paris-Saclay, Bures-sur-Yvette, France
| | - Vladislav Myrov
- Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
| | - Gabriele Arnulfo
- Neuroscience Center, HiLIFE-Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- Dept. of Informatics, Bioengineering, Robotics and System engineering, University of Genoa, Genoa, Italy
| | - Lino Nobili
- Child Neuropsychiatry Unit, IRCCS, Istituto G. Gaslini, Department of Neuroscience (DINOGMI), University of Genoa, Genoa, Italy
- "Claudio Munari" Epilepsy Surgery Centre, Niguarda Hospital, Milan, Italy
| | - J Matias Palva
- Centre for Cognitive Neuroimaging, School of Psychology and Neuroscience, University of Glasgow, Glasgow, UK
- Neuroscience Center, HiLIFE-Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland
- Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
| | - Satu Palva
- Centre for Cognitive Neuroimaging, School of Psychology and Neuroscience, University of Glasgow, Glasgow, UK.
- Neuroscience Center, HiLIFE-Helsinki Institute of Life Science, University of Helsinki, Helsinki, Finland.
| |
Collapse
|
34
|
Chiarello D, Tumminelli G, Sandrin F, Vilasi C, Castana L, Lo Russo G, Liava A, Francione S. Stereo-EEG tailored resection in a child with presumed perinatal post-stroke epilepsy: The complex organization of epileptogenic zone. Epilepsy Behav Rep 2023; 23:100616. [PMID: 37635920 PMCID: PMC10448411 DOI: 10.1016/j.ebr.2023.100616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 07/26/2023] [Accepted: 08/03/2023] [Indexed: 08/29/2023] Open
Abstract
Introduction Only a few studies have focused on tailored resection in post-stroke epilepsy, in which hemispherectomy and hemispherotomy are the most recognized treatments. Case description We describe the case of a patient with drug-resistant, presumed perinatal, post-stroke epilepsy and moderate right hemiparesis. The seizures were stereotyped, both spontaneous and induced by sudden noises and somatosensory stimuli. Considering the discordant anatomic-electro-clinical data - left perisylvian malacic lesion with electrical onset over the left mesial fronto-central leads - and the patient's functional preservation, SEEG was performed. SEEG revealed sub-continuous abnormalities in the perilesional regions. Several seizures were recorded, with onset over the premotor area, rapidly involving the motor and insular-opercular regions. We decided for a combined surgical approach, SEEG-guided radiofrequency thermocoagulation, on the fronto-mesial structure but also on the central operculum, followed by resective surgery including only the fronto-mesial structures. Discussion and conclusion The SEEG allowed to localize the epileptogenic zone far away from the anatomical lesion but connected to part of it. A combined surgical approach tailored on SEEG results allowed a good outcome (Engel Ib) without additional deficits.
Collapse
Affiliation(s)
- D. Chiarello
- “Claudio Munari” Epilepsy Surgery Center, GOM Niguarda, Milano, Italy
| | - G. Tumminelli
- Epilepsy Center, Child Neuropsychiatric Unit – ASST Santi Paolo e Carlo, Milan, Italy
| | - F. Sandrin
- “Claudio Munari” Epilepsy Surgery Center, GOM Niguarda, Milano, Italy
| | - C. Vilasi
- “Claudio Munari” Epilepsy Surgery Center, GOM Niguarda, Milano, Italy
| | - L. Castana
- “Claudio Munari” Epilepsy Surgery Center, GOM Niguarda, Milano, Italy
| | - G. Lo Russo
- “Claudio Munari” Epilepsy Surgery Center, GOM Niguarda, Milano, Italy
| | - A. Liava
- Child Neuropsychiatric Department - Azienda Sanitario Locale del Verbano Cusio Ossola, Verbania, Italy
| | - S. Francione
- “Claudio Munari” Epilepsy Surgery Center, GOM Niguarda, Milano, Italy
| |
Collapse
|
35
|
Yindeedej V, Uda T, Kawashima T, Koh S, Tanoue Y, Kojima Y, Goto T. Electrode Tip Shift During the Stereotactic Electroencephalography Evaluation Period with Boltless Suture Fixation. World Neurosurg 2023; 175:e1210-e1219. [PMID: 37427700 DOI: 10.1016/j.wneu.2023.04.099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 04/24/2023] [Indexed: 07/11/2023]
Abstract
BACKGROUND Electrodes for stereotactic electroencephalography (SEEG) are typically fixed to the skull with anchor bolts. When anchor bolts are unavailable, electrodes have to be fixed using other methods, carrying the possibility of electrode shift. This study, therefore, evaluated the characteristics of electrode tip shift during SEEG monitoring in patients with electrodes fixed using the suture technique. METHODS We retrospectively included patients who underwent SEEG implantation with suture fixation and evaluated the tip shift distance (TSD) of electrodes. Possible influences evaluated included: 1) implantation period, 2) lobe of entry, 3) unilateral or bilateral implantation, 4) electrode length, 5) skull thickness, and 6) scalp thickness difference. RESULTS A total of 50 electrodes in 7 patients were evaluated. TSD was 1.4 ± 2.0 mm (mean ± standard deviation). Implantation period was 8.1 ± 2.2 days. Entry lobe was frontal for 28 electrodes and temporal for 22 electrodes. Implantation was bilateral for 25 electrodes and unilateral for 25 electrodes. Electrode length was 45.4 ± 14.3 mm. Skull thickness was 6.0 ± 3.7 mm. Scalp thickness difference was -1.5 ± 2.1 mm, which was found greater in temporal lobe entry compared with frontal lobe entry. According to univariate analyses, neither implantation period nor electrode length correlated with TSD. Multivariate regression analysis showed that only greater scalp thickness difference correlated significantly with greater TSD (P = 0.0018). CONCLUSIONS Greater scalp thickness difference correlated with greater TSD. Surgeons need to consider the degree of scalp thickness difference and electrode shift when using suture fixation, especially with temporal lobe entry.
Collapse
Affiliation(s)
- Vich Yindeedej
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan; Division of Neurosurgery, Department of Surgery, Thammasat University Hospital, Faculty of Medicine, Thammasat University, Pathumthani, Thailand
| | - Takehiro Uda
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan.
| | - Toshiyuki Kawashima
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Saya Koh
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Yuta Tanoue
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Yuichiro Kojima
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| | - Takeo Goto
- Department of Neurosurgery, Osaka Metropolitan University, Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
36
|
Janca R, Tomasek M, Kalina A, Marusic P, Krsek P, Lesko R. Automated Identification of Stereoelectroencephalography Contacts and Measurement of Factors Influencing Accuracy of Frame Stereotaxy. IEEE J Biomed Health Inform 2023; 27:3326-3336. [PMID: 37389996 DOI: 10.1109/jbhi.2023.3271857] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/02/2023]
Abstract
OBJECTIVE Stereoelectroencephalography (SEEG) is an established invasive diagnostic technique for use in patients with drug-resistant focal epilepsy evaluated before resective epilepsy surgery. The factors that influence the accuracy of electrode implantation are not fully understood. Adequate accuracy prevents the risk of major surgery complications. Precise knowledge of the anatomical positions of individual electrode contacts is crucial for the interpretation of SEEG recordings and subsequent surgery. METHODS We developed an image processing pipeline to localize implanted electrodes and detect individual contact positions using computed tomography (CT), as a substitute for time-consuming manual labeling. The algorithm automates measurement of parameters of the electrodes implanted in the skull (bone thickness, implantation angle and depth) for use in modeling of predictive factors that influence implantation accuracy. RESULTS Fifty-four patients evaluated by SEEG were analyzed. A total of 662 SEEG electrodes with 8,745 contacts were stereotactically inserted. The automated detector localized all contacts with better accuracy than manual labeling (p < 0.001). The retrospective implantation accuracy of the target point was 2.4 ± 1.1 mm. A multifactorial analysis determined that almost 58% of the total error was attributable to measurable factors. The remaining 42% was attributable to random error. CONCLUSION SEEG contacts can be reliably marked by our proposed method. The trajectory of electrodes can be parametrically analyzed to predict and validate implantation accuracy using a multifactorial model. SIGNIFICANCE This novel, automated image processing technique is a potentially clinically important, assistive tool for increasing the yield, efficiency, and safety of SEEG.
Collapse
|
37
|
Männlin J, San Antonio-Arce V, Reinacher PC, Scheiwe C, Shah MJ, Urbach H, Schulze-Bonhage A. Safety profile of subdural and depth electrode implantations in invasive EEG exploration of drug-resistant focal epilepsy. Seizure 2023; 110:21-27. [PMID: 37302157 DOI: 10.1016/j.seizure.2023.05.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 05/15/2023] [Accepted: 05/31/2023] [Indexed: 06/13/2023] Open
Abstract
PURPOSE To analyze the safety profile of subdural and depth electrode implantation in a large monocentric cohort of patients of all ages undergoing intracranial EEG exploration because of drug resistant focal epilepsy diagnosed and implanted by a constant team of epileptologists and neurosurgeons. METHODS We retrospectively analyzed data from 452 implantations in 420 patients undergoing invasive presurgical evaluation at the Freiburg Epilepsy Center from 1999 to 2019 (n = 160 subdural electrodes, n = 156 depth electrodes and n = 136 combination of both approaches). Complications were classified as hemorrhage with or without clinical manifestations, infection-associated and other complications. Furthermore, possible risk factors (age, duration of invasive monitoring, number of electrode contacts used) and changes in complication rates during the study period were analyzed. RESULTS The most frequent complications in both implantation groups were hemorrhages. Subdural electrode explorations caused significantly more symptomatic hemorrhages and required more operative interventions (SDE 9.9%, DE 0.3%, p < 0.05). Hemorrhage risk was higher for grids with 64 contacts than for smaller grids (p < 0.05). The infection rate was very low (0,2%). A transient neurological deficit occurred in 8.8% of all implantations and persisted for at least 3 months in 1.3%. Transient, but not persistent neurological deficits were more common in patients with implanted subdural electrodes than in the depth electrode group. CONCLUSION The use of subdural electrodes was associated with a higher risk of hemorrhage and transient neurological symptoms. However persistent deficits were rare with either approach, demonstrating that intracranial investigations using either subdural electrodes or depth electrodes carry acceptable risks in patients with drug-resistant focal epilepsy.
Collapse
Affiliation(s)
- Julia Männlin
- Freiburg Epilepsy Center, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 64, Freiburg im Breisgau 79106, Germany.
| | - Victoria San Antonio-Arce
- Freiburg Epilepsy Center, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 64, Freiburg im Breisgau 79106, Germany; Member of the European Reference Network for Rare and Complex Epilepsies EpiCARE, Germany
| | - Peter Christoph Reinacher
- Department of Stereotactic and Functional Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 64, Freiburg im Breisgau 79106, Germany; Fraunhofer Institute for Laser Technology (ILT), Aachen, Germany
| | - Christian Scheiwe
- Department of Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 64, Freiburg im Breisgau 79106, Germany
| | - Mukesch Johannes Shah
- Department of Stereotactic and Functional Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 64, Freiburg im Breisgau 79106, Germany
| | - Horst Urbach
- Department of Neuroradiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 64, Freiburg im Breisgau 79106, Germany
| | - Andreas Schulze-Bonhage
- Freiburg Epilepsy Center, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacher Str. 64, Freiburg im Breisgau 79106, Germany; Member of the European Reference Network for Rare and Complex Epilepsies EpiCARE, Germany.
| |
Collapse
|
38
|
Joris V, Ribeiro-Vaz JG, Finet P, El Tahry R, Elkaim LM, Raftopoulos C, Ferrao-Santos S. Stereoelectroencephalography Implantation Using Frameless Neuronavigation and Varioguide: Prospective Analysis of Accuracy and Safety in a Case Series of 11 Patients. World Neurosurg 2023; 174:e62-e71. [PMID: 36871656 DOI: 10.1016/j.wneu.2023.02.116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 02/24/2023] [Indexed: 03/06/2023]
Abstract
BACKGROUND Stereoencephalography (SEEG) is becoming a widespread diagnostic procedure for drug-resistant epilepsy investigation. Techniques include frame-based and robot-assisted implantation, and more recently, frameless neuronavigated systems (FNSs). Despite its recent use, the accuracy and safety of FNS are still under investigation. OBJECTIVE To assess in a prospective study the accuracy and safety of a specific FNS use for SEEG implantation. METHODS Twelve patients who underwent SEEG implantation using FNS (Varioguide [Brainlab]) were included in this study. Data were collected prospectively and included demographic data, postoperative complications, functional results, and implantation characteristics (i.e., duration and number of electrodes). Further analysis included accuracy at entry point and target using measurements of the euclidean distance between planned and actual trajectories. RESULTS Eleven patients underwent SEEG-FNS implantation from May 2019 to March 2020. One patient did not undergo surgery because of a bleeding disorder. The mean target deviation was 4.06 mm, and mean entry point deviation was 4.2 mm, with insular electrodes significantly more deviated. Results excluding insular electrodes showed a mean target deviation of 3.66 mm and a mean entry point deviation of 3.77 mm. No severe complications occurred; a few mild to moderate adverse events were reported (1 superficial infection, 1 seizure cluster, and 3 transient neurologic impairments). The mean implantation duration by electrodes was 18.5 minutes. CONCLUSIONS Implantation of depth electrodes for SEEG using FNS seems to be safe, but larger prospective studies are needed to validate these results. Accuracy is sufficient for noninsular trajectories but warrant caution for insular trajectories with statistically significantly less accuracy.
Collapse
Affiliation(s)
- Vincent Joris
- Department of Neurosurgery, Cliniques Universitaires St-Luc, Woluwe-St-Lambert, Belgium.
| | | | - Patrice Finet
- Department of Neurosurgery, Cliniques Universitaires St-Luc, Woluwe-St-Lambert, Belgium
| | - Riëm El Tahry
- Department of Neurology, Cliniques Universitaires St-Luc, Woluwe-St-Lambert, Belgium
| | - Lior M Elkaim
- Division of Neurology and Neurosurgery, McGill University, McGill University Health Center, Montreal, Quebec, Canada
| | - Christian Raftopoulos
- Department of Neurosurgery, Cliniques Universitaires St-Luc, Woluwe-St-Lambert, Belgium
| | - Susana Ferrao-Santos
- Department of Neurology, Cliniques Universitaires St-Luc, Woluwe-St-Lambert, Belgium
| |
Collapse
|
39
|
Gomes FC, Larcipretti ALL, Nager G, Dagostin CS, Udoma-Udofa OC, Pontes JPM, de Oliveira JS, de Souza JHC, Bannach MDA. Robot-assisted vs. manually guided stereoelectroencephalography for refractory epilepsy: a systematic review and meta-analysis. Neurosurg Rev 2023; 46:102. [PMID: 37133774 DOI: 10.1007/s10143-023-01992-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/15/2023] [Accepted: 04/06/2023] [Indexed: 05/04/2023]
Abstract
Robotic assistance has improved electrode implantation precision in stereoelectroencephalography (SEEG) for refractory epilepsy patients. We sought to assess the relative safety of the robotic-assisted (RA) procedure compared to the traditional hand-guided one. A systematic search on PubMed, Web of Science, Embase, and Cochrane was performed for studies directly comparing robot-assisted vs. manually guided SEEG to treat refractory epilepsy. The primary outcomes included target point error (TPE), entry point error (EPE), time of implantation of each electrode, operative time, postoperative intracranial hemorrhage, infection, and neurologic deficit. We included 427 patients from 11 studies, of whom 232 (54.3%) underwent robot-assisted surgery and 196 (45.7%) underwent manually guided surgery. The primary endpoint, TPE, was not statistically significant (MD 0.04 mm; 95% CI - 0.21, - 0.29; p = 0.76). Nonetheless, EPE was significantly lower in the intervention group (MD - 0.57 mm; 95% CI - 1.08; - 0.06; p = 0.03). Total operative time was significantly lower in the RA group (MD - 23.66 min; 95% CI - 32.01, - 15.31; p < 0.00001), as well as the individual time of implantation of each electrode (MD - 3.35 min; 95% CI - 3.68, - 3.03; p < 0.00001). Postoperative intracranial hemorrhage did not differ between groups: robotic (9/145; 6.2%) vs. manual (8/139; 5.7%) (RR 0.97; 95% CI 0.40-2.34; p = 0.94). There was no statistically relevant difference in infection (p = 0.4) and postoperative neurological deficit (p = 0.47) incidence between the two groups. In this analysis, there is a potential relevance in the RA procedure when comparing the traditional one, since operative time, time of implantation of each electrode, and EPE were significantly lower in the robotic group. More research is needed to corroborate the superiority of this novel technique.
Collapse
Affiliation(s)
| | | | - Gabriela Nager
- Department of Medicine, Federal University of the State of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | | | | | | | | | - Matheus de Andrade Bannach
- Department of Surgery, Neurology and Neurosurgery Unit, Federal University of Goiás, Goiânia, 74690-900, Brazil.
| |
Collapse
|
40
|
Tiesinga P, Platonov A, Pelliccia V, LoRusso G, Sartori I, Orban GA. Uncovering the fast, directional signal flow through the human temporal pole during semantic processing. Sci Rep 2023; 13:6831. [PMID: 37100843 PMCID: PMC10133264 DOI: 10.1038/s41598-023-33318-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 04/11/2023] [Indexed: 04/28/2023] Open
Abstract
The temporal pole (TP) plays a central role in semantic memory, yet its neural machinery is unknown. Intracerebral recordings in patients discriminating visually the gender or actions of an actor, yielded gender discrimination responses in the ventrolateral (VL) and tip (T) regions of right TP. Granger causality revealed task-specific signals travelling first forward from VL to T, under control of orbitofrontal cortex (OFC) and neighboring prefrontal cortex, and then, strongly, backwards from T to VL. Many other cortical regions provided inputs to or received outputs from both TP regions, often with longer delays, with ventral temporal afferents to VL signaling the actor's physical appearance. The TP response timing reflected more that of the connections to VL, controlled by OFC, than that of the input leads themselves. Thus, visual evidence for gender categories, collected by VL, activates category labels in T, and consequently, category features in VL, indicating a two-stage representation of semantic categories in TP.
Collapse
Affiliation(s)
- P Tiesinga
- Neuroinformatics Department, Faculty of Science, Radboud University, Heyendaalseweg 135, 6525AJ, Nijmegen, The Netherlands.
| | - A Platonov
- Department of Medicine and Surgery, University of Parma, Via Volturno 39/E, 43125, Parma, Italy
| | - V Pelliccia
- Claudio Munari Center for Epilepsy Surgery, Ospedale Niguarda-Ca' Granda, 20162, Milan, Italy
| | - G LoRusso
- Claudio Munari Center for Epilepsy Surgery, Ospedale Niguarda-Ca' Granda, 20162, Milan, Italy
| | - I Sartori
- Claudio Munari Center for Epilepsy Surgery, Ospedale Niguarda-Ca' Granda, 20162, Milan, Italy
| | - G A Orban
- Department of Medicine and Surgery, University of Parma, Via Volturno 39/E, 43125, Parma, Italy.
| |
Collapse
|
41
|
Liu Q, Mao Z, Wang J, Wang C, Chen W, Chen W, Ye X, Zhang C, Lu Y, Xu J. The accuracy of a novel self-tapping bone fiducial marker for frameless robot-assisted stereo-electro-encephalography implantation and registration techniques. Int J Med Robot 2023; 19:e2479. [PMID: 36346988 DOI: 10.1002/rcs.2479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/30/2022] [Accepted: 11/01/2022] [Indexed: 11/10/2022]
Abstract
BACKGROUND We aimed to evaluate the accuracy and safety of a novel self-tapping bone fiducial as a registration technique for stereoelectroencephalography (SEEG) implantation. METHODS Each patient was installed with five bone fiducial markers. All procedures were performed using the same Sinovation robot system. The accuracy was determined by calculating the target point error (TPE) and the entry point error (EPE) of electrodes. RESULTS Fourteen patients underwent SEEG implantation surgery; and the average installation time of the markers per patient was 86.1 s. In the operating theatre, the average registration time was 206.6 s, and the average registration error was 0.18 mm. The average TPE of 174 electrodes was 1.98 mm and the average EPE was 0.88 mm. CONCLUSION Our study provided a bone fiducial marker installation and registration technique that was convenient and fast, highly accurate in registration, and highly tolerated by patients.
Collapse
Affiliation(s)
- Qiangqiang Liu
- Department of Neurosurgery, Clinical Neuroscience Center Comprehensive Epilepsy Unit, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ziyu Mao
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Junjie Wang
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Changquan Wang
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wenze Chen
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Wenzhen Chen
- Department of Neurosurgery, Clinical Neuroscience Center Comprehensive Epilepsy Unit, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xiaolai Ye
- Department of Neurosurgery, Clinical Neuroscience Center Comprehensive Epilepsy Unit, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Chencheng Zhang
- Department of Neurosurgery, Center for Functional Neurosurgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Shanghai Research Center for Brain Science and Brain-Inspired Technology, Shanghai, China
| | - Yong Lu
- Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jiwen Xu
- Department of Neurosurgery, Clinical Neuroscience Center Comprehensive Epilepsy Unit, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Clinical Neuroscience Center, Ruijin Hospital Luwan Branch, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
42
|
Oliveira LPD, Pérez-Enríquez C, Barguilla A, Langohr K, Conesa G, Infante N, Principe A, Rocamora R. Stereo-electroencephalography-guided radiofrequency thermocoagulation in patients with MRI-negative focal epilepsy. J Neurosurg 2023; 138:837-846. [PMID: 35962969 DOI: 10.3171/2022.6.jns22733] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 06/13/2022] [Indexed: 01/20/2023]
Abstract
OBJECTIVE Coupled with stereo-electroencephalography (SEEG), radiofrequency thermocoagulation (RFTC) has emerged as a therapeutic alternative for patients with refractory focal epilepsy, with proven safe but highly variable results across studies. The authors aimed to describe the outcomes and safety of SEEG-RFTC, focusing on patients with MRI-negative epilepsy. METHODS A retrospective observational study was conducted on patients evaluated by SEEG in the authors' center. Of 84 total cases, 55 underwent RFTC, with 31 MRI-negative epilepsies that were ultimately included in the study. The primary outcome was freedom from disabling seizures at last follow-up. Secondary outcomes were reduction in seizure frequency (RFTC response = seizure frequency reduction > 50%), peri-interventional complications, and neuropsychological outcomes. Potential factors influencing post-RFTC outcome were considered by comparing different variables between responders and nonresponders. RESULTS The mean follow-up period was 30.9 months (range 7.1-69.8 months). Three patients underwent subsequent resection/laser interstitial thermal therapy within the 1st year after RFTC failure. All other patients completed a minimum follow-up period of 1 year. Fourteen patients (45.2%) showed at least a 50% reduction in seizure frequency (responders), and 8 were seizure free (25.8% of the whole cohort). One case showed a permanent complication not directly related to thermolesions. Most patients (76%) showed no significant cognitive decline. Electrically elicited seizures (EESs) were observed in all seizure-free patients and were more frequent in responders (p = 0.038). All patients who were seizure free at the 6-month visit maintained their status during long-term follow-up. CONCLUSIONS SEEG-RFTC is a safe procedure and leads to a good response in many cases of MRI-negative focal epilepsies. One-quarter of the patients were seizure free and almost one-half were responders at the last follow-up. Although these results are still far from those achieved through conventional resection, a nonnegligible proportion of patients may benefit from this one-stage and much less invasive approach. Factors associated with seizure outcome remain to be elucidated; however, responders were significantly more frequent among patients with EESs, and achieving 6 months of seizure freedom appears to predict a good long-term response. In addition, the positive predictive value of RFTC response may be a valuable factor in the decision to proceed to subsequent surgery.
Collapse
Affiliation(s)
- Luísa Panadés-de Oliveira
- 1Epilepsy Monitoring Unit, Department of Neurology, Hospital del Mar.,2Epilepsy Research Group, Hospital del Mar Medical Research Institute (IMIM)
| | - Carmen Pérez-Enríquez
- 1Epilepsy Monitoring Unit, Department of Neurology, Hospital del Mar.,2Epilepsy Research Group, Hospital del Mar Medical Research Institute (IMIM)
| | - Ainara Barguilla
- 1Epilepsy Monitoring Unit, Department of Neurology, Hospital del Mar
| | - Klaus Langohr
- 3Department of Statistics and Operations Research, Universitat Politècnica de Catalunya BarcelonaTech.,4Integrative Pharmacology and Systems Neurosciences Research Group, Neurosciences Research Program, IMIM
| | - Gerardo Conesa
- 2Epilepsy Research Group, Hospital del Mar Medical Research Institute (IMIM).,5Department of Neurosurgery, Hospital del Mar; and
| | | | - Alessandro Principe
- 1Epilepsy Monitoring Unit, Department of Neurology, Hospital del Mar.,2Epilepsy Research Group, Hospital del Mar Medical Research Institute (IMIM).,6Biomedical Engineering, Department of Medicine and Life Sciences, Universitat Pompeu Fabra, Barcelona, Spain
| | - Rodrigo Rocamora
- 1Epilepsy Monitoring Unit, Department of Neurology, Hospital del Mar.,2Epilepsy Research Group, Hospital del Mar Medical Research Institute (IMIM).,6Biomedical Engineering, Department of Medicine and Life Sciences, Universitat Pompeu Fabra, Barcelona, Spain
| |
Collapse
|
43
|
Pacreu S, Moltó L, Fernández Candil JL, Vilà E. Anesthetic implications in the placement of deep brain electrodes through a stereotactic robot in the study of drug resistant epilepsy. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2023; 70:241-242. [PMID: 36842684 DOI: 10.1016/j.redare.2022.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 02/21/2022] [Indexed: 02/26/2023]
Affiliation(s)
- S Pacreu
- Servicio de Anestesiología y Reanimación y Tratamiento del Dolor, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain.
| | - L Moltó
- Servicio de Anestesiología y Reanimación y Tratamiento del Dolor, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain
| | - J L Fernández Candil
- Servicio de Anestesiología y Reanimación y Tratamiento del Dolor, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain
| | - E Vilà
- Servicio de Anestesiología y Reanimación y Tratamiento del Dolor, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain
| |
Collapse
|
44
|
Intracerebral Electrophysiological Recordings to Understand the Neural Basis of Human Face Recognition. Brain Sci 2023; 13:brainsci13020354. [PMID: 36831897 PMCID: PMC9954066 DOI: 10.3390/brainsci13020354] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 02/09/2023] [Accepted: 02/10/2023] [Indexed: 02/22/2023] Open
Abstract
Understanding how the human brain recognizes faces is a primary scientific goal in cognitive neuroscience. Given the limitations of the monkey model of human face recognition, a key approach in this endeavor is the recording of electrophysiological activity with electrodes implanted inside the brain of human epileptic patients. However, this approach faces a number of challenges that must be overcome for meaningful scientific knowledge to emerge. Here we synthesize a 10 year research program combining the recording of intracerebral activity (StereoElectroEncephaloGraphy, SEEG) in the ventral occipito-temporal cortex (VOTC) of large samples of participants and fast periodic visual stimulation (FPVS), to objectively define, quantify, and characterize the neural basis of human face recognition. These large-scale studies reconcile the wide distribution of neural face recognition activity with its (right) hemispheric and regional specialization and extend face-selectivity to anterior regions of the VOTC, including the ventral anterior temporal lobe (VATL) typically affected by magnetic susceptibility artifacts in functional magnetic resonance imaging (fMRI). Clear spatial dissociations in category-selectivity between faces and other meaningful stimuli such as landmarks (houses, medial VOTC regions) or written words (left lateralized VOTC) are found, confirming and extending neuroimaging observations while supporting the validity of the clinical population tested to inform about normal brain function. The recognition of face identity - arguably the ultimate form of recognition for the human brain - beyond mere differences in physical features is essentially supported by selective populations of neurons in the right inferior occipital gyrus and the lateral portion of the middle and anterior fusiform gyrus. In addition, low-frequency and high-frequency broadband iEEG signals of face recognition appear to be largely concordant in the human association cortex. We conclude by outlining the challenges of this research program to understand the neural basis of human face recognition in the next 10 years.
Collapse
|
45
|
Hines K, Matias CM, Leibold A, Sharan A, Wu C. Accuracy and efficiency using frameless transient fiducial registration in stereoelectroencephalography and deep brain stimulation. J Neurosurg 2023; 138:299-305. [PMID: 35901701 DOI: 10.3171/2022.5.jns22804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/19/2022] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Stereotactic surgical methods continue to advance technologically. Frameless transient fiducial registration (FTFR) systems have been developed and avoid the need to move or position a patient in a frame after already receiving registration imaging. One such system, Neurolocate, has recently become available as a robotic attachment for the Neuromate stereotactic robot. This study is the largest in the literature to evaluate the accuracy of frameless registration using Neurolocate versus frame-based registration (FBR) methods in both deep brain stimulation (DBS) and stereoelectroencephalography (SEEG). Additionally, the authors sought to reevaluate factors affecting accuracy in both procedures. METHODS This study was a retrospective chart and imaging review of 88 consecutive procedures (involving 621 electrodes) implanting either DBS or SEEG at the authors' institution over a 5-year period from March 2015 to March 2020. Registration duration, radial target entry point, and Euclidean target implantation accuracies, as well as factors affecting accuracy, were recorded for each patient. RESULTS SEEG procedures included 38 patients and 525 implanted electrodes (294 using FBR and 231 using FTFR). DBS procedures included 50 patients and 96 implanted electrodes (65 using FBR and 31 using FTFR). Overall, FTFR registration was significantly more accurate (median 0.1 mm, IQR 0-0.4 mm) compared with FBR (median 1.3 mm, IQR 0.9-1.5 mm; p = 0.04). Likewise, FTFR had a significantly shorter duration of registration (median 84 minutes, IQR 77.3-95.3 minutes) when compared with FBR (median 110.5 minutes, IQR 107.3-138 minutes; p = 0.02). No significant differences were found when examining the radial entry point and Euclidean target implantation errors of each method. CONCLUSIONS FTFR with the Neurolocate system represents a technique that may decrease operative time while maintaining the high accuracy previously demonstrated by other stereotactic methods, despite an initial surgeon learning curve. It should be investigated in future studies to continue to improve stereotactic accuracies in neurosurgery.
Collapse
Affiliation(s)
- Kevin Hines
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Caio M. Matias
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Adam Leibold
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Ashwini Sharan
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| | - Chengyuan Wu
- Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania
| |
Collapse
|
46
|
Stangler LA, Nicolai EN, Mivalt F, Chang SY, Kim I, Kouzani AZ, Bennet K, Berk M, Uthamaraj S, Burns TC, Worrell GA, Howe CL. Development of an integrated microperfusion-EEG electrode for unbiased multimodal sampling of brain interstitial fluid and concurrent neural activity. J Neural Eng 2023; 20:016010. [PMID: 36538815 PMCID: PMC9855636 DOI: 10.1088/1741-2552/acad29] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 12/20/2022] [Indexed: 12/24/2022]
Abstract
Objective. To modify off-the-shelf components to build a device for collecting electroencephalography (EEG) from macroelectrodes surrounded by large fluid access ports sampled by an integrated microperfusion system in order to establish a method for sampling brain interstitial fluid (ISF) at the site of stimulation or seizure activity with no bias for molecular size.Approach. Twenty-four 560µm diameter holes were ablated through the sheath surrounding one platinum-iridium macroelectrode of a standard Spencer depth electrode using a femtosecond UV laser. A syringe pump was converted to push-pull configuration and connected to the fluidics catheter of a commercially available microdialysis system. The fluidics were inserted into the lumen of the modified Spencer electrode with the microdialysis membrane removed, converting the system to open flow microperfusion. Electrical performance and analyte recovery were measured and parameters were systematically altered to improve performance. An optimized device was tested in the pig brain and unbiased quantitative mass spectrometry was used to characterize the perfusate collected from the peri-electrode brain in response to stimulation.Main results. Optimized parameters resulted in >70% recovery of 70 kDa dextran from a tissue analog. The optimized device was implanted in the cortex of a pig and perfusate was collected during four 60 min epochs. Following a baseline epoch, the macroelectrode surrounded by microperfusion ports was stimulated at 2 Hz (0.7 mA, 200µs pulse width). Following a post-stimulation epoch, the cortex near the electrode was stimulated with benzylpenicillin to induce epileptiform activity. Proteomic analysis of the perfusates revealed a unique inflammatory signature induced by electrical stimulation. This signature was not detected in bulk tissue ISF.Significance. A modified dual-sensing electrode that permits coincident detection of EEG and ISF at the site of epileptiform neural activity may reveal novel pathogenic mechanisms and therapeutic targets that are otherwise undetectable at the bulk tissue level.
Collapse
Affiliation(s)
- Luke A Stangler
- School of Engineering, Deakin University, Geelong, Victoria 3216, Australia,
Division of Engineering, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Evan N Nicolai
- Mayo Clinic Graduate School of Biomedical Sciences, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Filip Mivalt
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, United States of America,
Department of Neurology, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Su-Youne Chang
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, United States of America,
Department of Neurologic Surgery, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Inyong Kim
- Department of Neurology, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Abbas Z Kouzani
- School of Engineering, Deakin University, Geelong, Victoria 3216, Australia
| | - Kevin Bennet
- Division of Engineering, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Michael Berk
- School of Medicine, Deakin University, Geelong, Victoria 3216, Australia
| | - Susheil Uthamaraj
- Division of Engineering, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Terry C Burns
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Gregory A Worrell
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, United States of America,
Department of Neurology, Mayo Clinic, Rochester, MN 55905, United States of America
| | - Charles L Howe
- Department of Neurology, Mayo Clinic, Rochester, MN 55905, United States of America,
Division of Experimental Neurology, Mayo Clinic, Rochester, MN 55905, United States of America,Author to whom any correspondence should be addressed
| |
Collapse
|
47
|
MAESAWA S, ISHIZAKI T, MUTOH M, ITO Y, TORII J, TANEI T, NAKATSUBO D, SAITO R. Clinical Impacts of Stereotactic Electroencephalography on Epilepsy Surgery and Associated Issues in the Current Situation in Japan. Neurol Med Chir (Tokyo) 2023; 63:179-190. [PMID: 37005247 DOI: 10.2176/jns-nmc.2022-0271] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2023] Open
Abstract
Stereotactic electroencephalography (SEEG) is receiving increasing attention as a safe and effective technique in the invasive evaluation for epileptogenic zone (EZ) detection. The main clinical question is whether the use of SEEG truly improves outcomes. Herein, we compared outcomes in our patients after three types of intracranial EEG (iEEG): SEEG, the subdural electrode (SDE), and a combined method using depth and strip electrodes. We present here our preliminary results from two demonstrative cases. Several international reports from large epilepsy centers found the following clinical advantages of SEEG: 1) three-dimensional analysis of structures, including bilateral and multilobar structures; 2) low rate of complications; 3) less pneumoencephalopathy and less patient burden during postoperative course, which allows the initiation of video-EEG monitoring immediately after implantation and does not require resection to be performed in the same hospitalization; and 4) a higher rate of good seizure control after resection. In other words, SEEG more accurately identified the EZ than the SDE method. We obtained similar results in our preliminary experiences under limited conditions. In Japan, as of August 2022, dedicated electrodes and SEEG accessories have not been approved and the use of the robot arm is not widespread. The Japanese medical community is hopeful that these issues will soon be resolved and that the experience with SEEG in Japan will align with that of large epilepsy centers internationally.
Collapse
Affiliation(s)
- Satoshi MAESAWA
- Department of Neurosurgery, Nagoya University School of Medicine
| | | | - Manabu MUTOH
- Department of Neurosurgery, Nagoya University School of Medicine
| | - Yoshiki ITO
- Department of Neurosurgery, Nagoya University School of Medicine
| | - Jun TORII
- Department of Neurosurgery, Nagoya University School of Medicine
| | - Takafumi TANEI
- Department of Neurosurgery, Nagoya University School of Medicine
| | | | - Ryuta SAITO
- Department of Neurosurgery, Nagoya University School of Medicine
| |
Collapse
|
48
|
Shlobin NA, Huang J, Wu C. Learning curves in robotic neurosurgery: a systematic review. Neurosurg Rev 2022; 46:14. [PMID: 36504244 DOI: 10.1007/s10143-022-01908-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The transition to performing procedures robotically generally entails a period of adjustment known as a learning curve as the surgeon develops a familiarity with the technology. However, no study has comprehensively examined robotic learning curves across the field of neurosurgery. We conducted a systematic review to characterize the scope of literature on robotic learning curves in neurosurgery, assess operative parameters that may involve a learning curve, and delineate areas for future investigation. PubMed, Embase, and Scopus were searched. Following deduplication, articles were screened by title and abstract for relevance. Remaining articles were screened via full text for final inclusion. Bibliographic and learning curve data were extracted. Of 746 resultant articles, 32 articles describing 3074 patients were included, of which 23 (71.9%) examined spine, 4 (12.5%) pediatric, 4 (12.5%) functional, and 1 (3.1%) general neurosurgery. The parameters assessed for learning curves were heterogeneous. In total, 8 (57.1%) of 14 studies found reduced operative time with increased cases, while the remainder demonstrated no learning curve. Six (60.0%) of 10 studies reported reduced operative time per component with increased cases, while the remainder indicated no learning curve. Radiation time, radiation time per component, robot time, registration time, setup time, and radiation dose were assessed by ≤ 4 studies each, with 0-66.7% of studies demonstrated a learning curve. Four (44.4%) of 9 studies on accuracy showed improvement over time, while the others indicated no improvement over time. The number of cases required to reverse the learning curve ranged from 3 to 75. Learning curves are common in robotic neurosurgery. However, existing studies demonstrate high heterogeneity in assessed parameters and the number of cases that comprise the learning curve. Future studies should seek to develop strategies to reduce the number of cases required to reach the learning curve.
Collapse
Affiliation(s)
- Nathan A Shlobin
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, 676 N. St. Clair Street, Suite 2210, Chicago, IL, 60611, USA.
| | - Jonathan Huang
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, 676 N. St. Clair Street, Suite 2210, Chicago, IL, 60611, USA
| | - Chengyuan Wu
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, PA, USA
| |
Collapse
|
49
|
A comparison between robot-guided and stereotactic frame-based stereoelectroencephalography (SEEG) electrode implantation for drug-resistant epilepsy. J Robot Surg 2022; 17:1013-1020. [DOI: 10.1007/s11701-022-01504-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 11/21/2022] [Indexed: 12/03/2022]
|
50
|
Vila‐Vidal M, Khawaja M, Carreño M, Roldán P, Rumià J, Donaire A, Deco G, Tauste Campo A. Assessing the coupling between local neural activity and global connectivity fluctuations: Application to human intracranial electroencephalography during a cognitive task. Hum Brain Mapp 2022; 44:1173-1192. [PMID: 36437716 PMCID: PMC9875936 DOI: 10.1002/hbm.26150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 10/17/2022] [Accepted: 10/20/2022] [Indexed: 11/29/2022] Open
Abstract
Cognitive-relevant information is processed by different brain areas that cooperate to eventually produce a response. The relationship between local activity and global brain states during such processes, however, remains for the most part unexplored. To address this question, we designed a simple face-recognition task performed in patients with drug-resistant epilepsy and monitored with intracranial electroencephalography (EEG). Based on our observations, we developed a novel analytical framework (named "local-global" framework) to statistically correlate the brain activity in every recorded gray-matter region with the widespread connectivity fluctuations as proxy to identify concurrent local activations and global brain phenomena that may plausibly reflect a common functional network during cognition. The application of the local-global framework to the data from three subjects showed that similar connectivity fluctuations found across patients were mainly coupled to the local activity of brain areas involved in face information processing. In particular, our findings provide preliminary evidence that the reported global measures might be a novel signature of functional brain activity reorganization when a stimulus is processed in a task context regardless of the specific recorded areas.
Collapse
Affiliation(s)
- Manel Vila‐Vidal
- Center for Brain and Cognition, Department of Information and Communication TechnologiesUniversitat Pompeu FabraBarcelonaSpain,Computational Biology and Complex Systems Group, Department of PhysicsUniversitat Politècnica de CatalunyaBarcelonaSpain
| | | | - Mar Carreño
- Epilepsy ProgramHospital ClínicBarcelonaSpain,Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS)BarcelonaSpain
| | - Pedro Roldán
- Epilepsy Program, NeurosurgeryHospital ClínicBarcelonaSpain
| | - Jordi Rumià
- Epilepsy Program, NeurosurgeryHospital ClínicBarcelonaSpain
| | - Antonio Donaire
- Epilepsy ProgramHospital ClínicBarcelonaSpain,Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS)BarcelonaSpain,CIBERBBN, Networking Centre on Bioengineering, Biomaterials and NanomedicineBarcelonaSpain
| | - Gustavo Deco
- Computational Biology and Complex Systems Group, Department of PhysicsUniversitat Politècnica de CatalunyaBarcelonaSpain,Institució Catalana de Recerca i Estudis AvançatsBarcelonaSpain
| | - Adrià Tauste Campo
- Center for Brain and Cognition, Department of Information and Communication TechnologiesUniversitat Pompeu FabraBarcelonaSpain,Computational Biology and Complex Systems Group, Department of PhysicsUniversitat Politècnica de CatalunyaBarcelonaSpain
| |
Collapse
|