1
|
Khan AZ, Maxwell MJ, Parrott RM, Bowler AR, Glass EA, Miller D, Vasconcellos D, Brownhill JR, Austin LS, Cuff DJ, Murthi AM, Smith MJ, Wiater JM, Jawa A. Effect of vitamin E-enhanced highly cross-linked polyethylene on wear rate and particle debris in anatomic total shoulder arthroplasty: a biomechanical comparison to ultrahigh-molecular-weight polyethylene. J Shoulder Elbow Surg 2024; 33:1465-1472. [PMID: 38182025 DOI: 10.1016/j.jse.2023.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 11/03/2023] [Accepted: 11/14/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Particle-induced osteolysis resulting from polyethylene wear remains a source of implant failure in anatomic total shoulder designs. Modern polyethylene components are irradiated in an oxygen-free environment to induce cross-linking, but reducing the resulting free radicals with melting or heat annealing can compromise the component's mechanical properties. Vitamin E has been introduced as an adjuvant to thermal treatments. Anatomic shoulder arthroplasty models with a ceramic head component have demonstrated that vitamin E-enhanced polyethylene show improved wear compared with highly cross-linked polyethylene (HXLPE). This study aimed to assess the biomechanical wear properties and particle size characteristics of a novel vitamin E-enhanced highly cross-linked polyethylene (VEXPE) glenoid compared to a conventional ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid against a cobalt chromium molybdenum (CoCrMo) head component. METHODS Biomechanical wear testing was performed to compare the VEXPE glenoid to UHMWPE glenoid with regard to pristine polyethylene wear and abrasive endurance against a polished CoCrMo alloy humeral head in an anatomic shoulder wear-simulation model. Cumulative mass loss (milligrams) was recorded, and wear rate calculated (milligrams per megacycle [Mc]). Under pristine wear conditions, particle analysis was performed, and functional biologic activity (FBA) was calculated to estimate particle debris osteolytic potential. In addition, 95% confidence intervals for all testing conditions were calculated. RESULTS The average pristine wear rate was statistically significantly lower for the VEXPE glenoid compared with the HXLPE glenoid (0.81 ± 0.64 mg/Mc vs. 7.00 ± 0.45 mg/Mc) (P < .05). Under abrasive wear conditions, the VEXPE glenoid had a statistically significant lower average wear rate compared with the UHMWPE glenoid comparator device (18.93 ± 5.80 mg/Mc vs. 40.47 ± 2.63 mg/Mc) (P < .05). The VEXPE glenoid demonstrated a statistically significant improvement in FBA compared with the HXLPE glenoid (0.21 ± 0.21 vs. 1.54 ± 0.49 (P < .05). CONCLUSIONS A new anatomic glenoid component with VEXPE demonstrated significantly improved pristine and abrasive wear properties with lower osteolytic particle debris potential compared with a conventional UHMWPE glenoid component. Vitamin E-enhanced polyethylene shows early promise in shoulder arthroplasty components. Long-term clinical and radiographic investigation needs to be performed to verify if these biomechanical wear properties translate to diminished long-term wear, osteolysis, and loosening.
Collapse
Affiliation(s)
- Adam Z Khan
- Northwest Permanente P.C., Portland, OR, USA
| | | | | | | | | | | | | | | | - Luke S Austin
- Department of Orthopaedic Surgery, The Rothman Institute, Philadelphia, PA, USA
| | - Derek J Cuff
- Suncoast Orthopaedic Surgery and Sports Medicine, Venice, FL, USA
| | | | - Matthew J Smith
- Department of Orthopedic Surgery, University of Missouri, Columbia, MO, USA
| | - J Michael Wiater
- Department of Orthopaedic Surgery, Beaumont Hospital, Royal Oak, MI, USA
| | - Andrew Jawa
- New England Baptist Hospital, Boston, MA, USA.
| |
Collapse
|
2
|
Kalashnikov O, Sulyma O, Osadchuk T, Zayets V, Nizalov T, Kozak R, Chernyak P. Use of hyaluronic acid preparations for treatment of osteoarthritis of major ligaments. PAIN MEDICINE 2021. [DOI: 10.31636/pmjua.v6i2.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The authors of the article analyzed the experience of domestic and foreign experts in the effectiveness of the use of HA preparations in the treatment of osteoarthritis of major ligaments.
Background and Objective. To analyze the literature sources in order to determine the effectiveness of the use of HA preparations in the treatment of osteoarthritis of major ligaments.
Materials and methods. Articles in specialized scientific journals and collections, Internet resource.
Results. The analysis of literature sources determined the important role of HA preparations in the supplying and functioning of the articular cartilage. Researchers are inclined to believe that the ideal HA preparation should be as close as possible to the physiological HA of the synovial fluid of the joint. The developed domestic drug Arthro-Patch fully corresponds to these parameters.
Conclusions. The use of modern injectable HA preparations is advisable at stages 1–3 of OA. Anti-inflammatory effect of HA preparations makes it possible to reduce the dose and time of administration of non-steroidal anti-inflammatory drugs and, as a consequence, reduce the risk of developing many adverse side effects of NSAIDs. The high level of safety of HA preparations, the absence of serious side effects during their long-term use determine their widespread use in the clinical practice of modern orthopedists.
Collapse
|
3
|
Schwiesau J, Fritz B, Bergmann G, Puente Reyna AL, Schilling C, Grupp TM. Influence of radiation conditions on the wear behaviour of Vitamin E treated UHMWPE gliding components for total knee arthroplasty after extended artificial aging and simulated daily patient activities. J Mech Behav Biomed Mater 2021; 122:104652. [PMID: 34246078 DOI: 10.1016/j.jmbbm.2021.104652] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 06/08/2021] [Accepted: 06/16/2021] [Indexed: 10/21/2022]
Abstract
The long term performance of total knee arthroplasty (TKA) with regards to the bearing materials is related to the aging behaviour of these materials. The use of highly crosslinked materials in hip arthroplasty improved the clinical outcome. Nevertheless, the outcome for these materials compared to conventional UHMWPE (ultra-high molecular weight polyethylene) remains controversial in TKA and alternative bearing materials may be advantageous to improve its outcome in the second and third decade. The aim of this study is the evaluation of the influence of radiation conditions on the wear behaviour of Vitamin E blended UHMWPE gliding components for TKA by simulation of extended aging and high demanding daily patient activities. For a medium radiation dose (30 kGy), the influence of the irradiation type (E-beam or Gamma radiation) and the thermal conditions (room temperature (RT) or heated to 115 °C) are evaluated in comparison to non-irradiated material. Significant influences on the wear behaviour were found for the radiation source and temperature during irradiation. Furthermore, no relevant degradation of the tested materials was observed after extended artificial aging. There was a good correspondence between the wear pattern in this study and retrievals.
Collapse
Affiliation(s)
- Jens Schwiesau
- Aesculap AG Research & Development, Tuttlingen, Germany; Ludwig Maximilians University Munich Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern, Munich, Germany.
| | | | - Georg Bergmann
- Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | | | | | - Thomas M Grupp
- Aesculap AG Research & Development, Tuttlingen, Germany; Ludwig Maximilians University Munich Department of Orthopaedic Surgery, Physical Medicine & Rehabilitation, Campus Grosshadern, Munich, Germany
| |
Collapse
|
4
|
Hameister R, Kaur C, Dheen ST, Lohmann CH, Singh G. Reactive oxygen/nitrogen species (ROS/RNS) and oxidative stress in arthroplasty. J Biomed Mater Res B Appl Biomater 2020; 108:2073-2087. [PMID: 31898397 DOI: 10.1002/jbm.b.34546] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/19/2019] [Accepted: 12/08/2019] [Indexed: 12/16/2022]
Abstract
The interplay between implant design, biomaterial characteristics, and the local microenvironment adjacent to the implant is of utmost importance for implant performance and success of the joint replacement surgery. Reactive oxygen and nitrogen species (ROS/RNS) are among the various factors affecting the host as well as the implant components. Excessive formation of ROS and RNS can lead to oxidative stress, a condition that is known to damage cells and tissues and also to affect signaling pathways. It may further compromise implant longevity by accelerating implant degradation, primarily through activation of inflammatory cells. In addition, wear products of metallic, ceramic, polyethylene, or bone cement origin may also generate oxidative stress themselves. This review outlines the generation of free radicals and oxidative stress in arthroplasty and provides a conceptual framework on its implications for soft tissue remodeling and bone resorption (osteolysis) as well as implant longevity. Key findings derived from cell culture studies, animal models, and patients' samples are presented. Strategies to control oxidative stress by implant design and antioxidants are explored and areas of controversy and challenges are highlighted. Finally, directions for future research are identified. A better understanding of the host-implant interplay and the role of free radicals and oxidative stress will help to evaluate therapeutic approaches and will ultimately improve implant performance in arthroplasty.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shaikali Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Gurpal Singh
- Centre for Orthopaedics Pte Ltd, Singapore, Singapore
| |
Collapse
|
5
|
Spece H, Schachtner JT, MacDonald DW, Klein GR, Mont MA, Lee GC, Kurtz SM. Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty. J Arthroplasty 2019; 34:3088-3093. [PMID: 31416742 PMCID: PMC6864268 DOI: 10.1016/j.arth.2019.07.018] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 07/11/2019] [Accepted: 07/14/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In order to improve oxidation resistance, antioxidants such as vitamin-E are added to polyethylene used in the bearing surfaces of orthopedic components. Currently, little is known about the efficacy of this treatment in vivo. This study therefore reports on the reasons for revision, surface damage mechanisms, and oxidation of retrieved vitamin E-stabilized highly crosslinked polyethylene (HXLPE) for total knee arthroplasty. METHODS We examined 103 retrieved knee inserts fabricated from vitamin E (VE)-stabilized HXLPE and 67 fabricated from remelted HXLPE as a control. The implantation times were 1.2 ± 1.3 and 1.5 ± 1.3 years for the VE and control cohorts, respectively. The inserts were evaluated for 7 surface damage mechanisms using a semiquantitative scoring method and analyzed for oxidation using Fourier-transform infrared spectroscopy. Reasons for revision were also assessed using operative notes created at time of retrieval. RESULTS Both groups were revised primarily for instability, infection, and loosening. Burnishing, pitting, and scratching were the most common damage mechanisms observed, with the VE cohort demonstrating less surface damage than the control. Measured oxidation for the cohort was low, with a median oxidation index of 0.09 ± .05 for the articulating surface, 0.05 ± 0.06 for the backside, 0.08 ± 0.06 for the anterior/posterior surfaces, and 0.08 ± 0.05 for the stabilizing post. As compared to the control cohort, oxidation tended to be less for the VE group at the articulating (P < .001) and backside (P = .003) surfaces, although the median differences were minimal and may not be clinically significant. CONCLUSION The results indicate positive fatigue damage resistance and oxidation resistance for the retrieved VE-stabilized total knee arthroplasty inserts.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Center at Drexel University, Philadelphia, PA
| | | | | | - Gregg R. Klein
- Hartzband Center for Hip and Knee Replacement, Paramus, NJ
| | | | - Gwo-Chin Lee
- Department of Orthopaedic Surgery, Penn Presbyterian Medical Center, University of Pennsylvania, Philadelphia, PA
| | - Steven M. Kurtz
- Implant Research Center at Drexel University, Philadelphia, PA,Exponent, Inc, Philadelphia, PA
| |
Collapse
|
6
|
Yao L, Li C, Li J. [Research progress in artificial metacarpophalangeal joint and interphalangeal joint prostheses]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2019; 33:1326-1330. [PMID: 31544447 DOI: 10.7507/1002-1892.201902015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To summarize the research progress in artificial metacarpophalangeal joint and interphalangeal joint prostheses. Methods The research literature on artificial metacarpophalangeal joint and interphalangeal joint prostheses at home and abroad was reviewed and summarized from anatomy, prosthesis design, and material development. Results The artificial joint replacement can correct deformity, relieve pain, and improve function immediately. In the past 50 years, many researches have focused on the design and material of prostheses and surgical technique of joint replacement. There are three types of prostheses, including hinged limit-type-prosthesis, semi-limit-type-prosthesis, and non-limit-type-prosthesis. The prostheses have their own advantages and disadvantages, the long-term effectiveness of joint replacement is not ideal. Conclusion The metacarpophalangeal joint and interphalangeal joint prostheses with more anatomical structure and biocompatible materials are needed.
Collapse
Affiliation(s)
- Ling Yao
- Department of Orthopedics, 920 Hospital of Joint Logistic Support Force of Chinese PLA, Kunming Yunnan, 650100, P.R.China;Department of Graduates, Kunming Medical University, Kunming Yunnan, 650500, P.R.China
| | - Chuan Li
- Department of Orthopedics, 920 Hospital of Joint Logistic Support Force of Chinese PLA, Kunming Yunnan, 650100, P.R.China
| | - Jun Li
- Department of Orthopedics, 920 Hospital of Joint Logistic Support Force of Chinese PLA, Kunming Yunnan, 650100,
| |
Collapse
|
7
|
Wilhelm SK, Henrichsen JL, Siljander M, Moore D, Karadsheh M. Polyethylene in total knee arthroplasty: Where are we now? J Orthop Surg (Hong Kong) 2019; 26:2309499018808356. [PMID: 30369289 DOI: 10.1177/2309499018808356] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Polyethylene (PE) remains the gold standard for the articulating surface in hip and knee arthroplasty. To increase arthroplasty longevity and improve wear resistance, newer versions of PE have been designed with resultantly different wear properties. Highly cross-linked polyethylene (HXLPE) is used in total hip arthroplasty with excellent outcomes; however, its use in total knee arthroplasty (TKA) remains conflicting. This review summarizes biomechanical and wear properties, clinical outcomes, and cost of polyethylene inserts in TKA. Simulation studies have convincingly shown decreased wear and oxidation rates with HXLPE when compared to conventional polyethylene (CPE). Registry results have been conflicting, and short- to midterm clinical studies have not demonstrated a significant difference between HXLPE and CPE. The cost of HXLPE inserts is higher than CPE. Long-term clinical data are lacking and further studies are warranted to evaluate the role of HXLPE in TKA.
Collapse
Affiliation(s)
- Spencer K Wilhelm
- 1 Oakland University William Beaumont School of Medicine, Michigan, USA
| | | | | | - Drew Moore
- 2 Beaumont Health System, Orthopaedic Surgery, Michigan, USA
| | - Mark Karadsheh
- 2 Beaumont Health System, Orthopaedic Surgery, Michigan, USA
| |
Collapse
|
8
|
The effect of vitamin E-enhanced cross-linked polyethylene on wear in shoulder arthroplasty-a wear simulator study. J Shoulder Elbow Surg 2019; 28:1771-1778. [PMID: 31029519 DOI: 10.1016/j.jse.2019.01.014] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 01/14/2019] [Accepted: 01/21/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Wear of the polyethylene glenoid component and subsequent particle-induced osteolysis remains one of the most important modes of failure of total shoulder arthroplasty. Vitamin E is added to polyethylene to act as an antioxidant to stabilize free radicals that exist as a byproduct of irradiation used to induce cross-linking. This study was performed to assess the in vitro performance of vitamin E-enhanced polyethylene compared with conventional polyethylene in a shoulder simulator model. METHODS Vitamin E-enhanced, highly cross-linked glenoid components were compared with conventional ultrahigh-molecular-weight polyethylene glenoids, both articulating with a ceramic humeral head component using a shoulder joint simulator over 500,000 cycles. Unaged and artificially aged comparisons were performed. Volumetric wear was assessed by gravimetric measurement, and wear particle analysis was also subsequently performed. RESULTS Vitamin E-enhanced polyethylene glenoid components were found to have significantly reduced wear rates compared with conventional polyethylene in both unaged (36% reduction) and artificially aged (49% reduction) comparisons. There were no differences detected in wear particle analysis between the 2 groups. CONCLUSION Vitamin E-enhanced polyethylene demonstrates improved wear compared with conventional polyethylene in both unaged and artificially aged comparisons and may have clinically relevant benefits.
Collapse
|
9
|
Takemura S, Minoda Y, Sugama R, Ohta Y, Nakamura S, Ueyama H, Nakamura H. Comparison of a vitamin E-infused highly crosslinked polyethylene insert and a conventional polyethylene insert for primary total knee arthroplasty at two years postoperatively. Bone Joint J 2019; 101-B:559-564. [PMID: 31039001 DOI: 10.1302/0301-620x.101b5.bjj-2018-1355.r1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
AIMS The use of vitamin E-infused highly crosslinked polyethylene (HXLPE) in total knee prostheses is controversial. In this paper we have compared the clinical and radiological results between conventional polyethylene and vitamin E-infused HXLPE inserts in total knee arthroplasty (TKA). PATIENTS AND METHODS The study included 200 knees (175 patients) that underwent TKA using the same total knee prostheses. In all, 100 knees (77 patients) had a vitamin E-infused HXLPE insert (study group) and 100 knees (98 patients) had a conventional polyethylene insert (control group). There were no significant differences in age, sex, diagnosis, preoperative knee range of movement (ROM), and preoperative Knee Society Score (KSS) between the two groups. Clinical and radiological results were evaluated at two years postoperatively. RESULTS Differences in postoperative ROM and KSS were not statistically significant between the study and control groups. No knee exhibited osteolysis, aseptic loosening, or polyethylene failure. Additionally, there was no significant difference in the incidence of a radiolucent line between the two groups. One patient from the study group required irrigation and debridement, due to deep infection, at six months postoperatively. CONCLUSION Clinical results were comparable between vitamin E-infused HXLPE inserts and conventional polyethylene inserts at two years after TKA, without any significant clinical failure. Cite this article: Bone Joint J 2019;101-B:559-564.
Collapse
Affiliation(s)
- S Takemura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Minoda
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - R Sugama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Ohta
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - S Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Ueyama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
10
|
Okazaki Y, Hosoba M, Miura S, Mochizuki T. Effects of knee simulator control method and radiation dose on UHMWPE wear rate, and relationship between wear rate and clinical revision rate in National Joint Registry. J Mech Behav Biomed Mater 2019; 90:182-190. [DOI: 10.1016/j.jmbbm.2018.09.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 09/21/2018] [Accepted: 09/24/2018] [Indexed: 10/28/2022]
|
11
|
Ponzio DY, Weitzler L, deMeireles A, Esposito CI, Wright TM, Padgett DE. Antioxidant-stabilized highly crosslinked polyethylene in total knee arthroplasty. Bone Joint J 2018; 100-B:1330-1335. [DOI: 10.1302/0301-620x.100b10.bjj-2018-0061.r2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims The aim of this study was to evaluate the surface damage, the density of crosslinking, and oxidation in retrieved antioxidant-stabilized highly crosslinked polyethylene (A-XLPE) tibial inserts from total knee arthroplasty (TKA), and to compare the results with a matched cohort of standard remelted highly crosslinked polyethylene (XLPE) inserts. Materials and Methods A total of 19 A-XLPE tibial inserts were retrieved during revision TKA and matched to 18 retrieved XLPE inserts according to the demographics of the patients, with a mean length of implantation of 15 months (1 to 42). The percentage areas of PE damage on the articular surfaces and the modes of damage were measured. The density of crosslinking of the PE and oxidation were measured at loaded and unloaded regions on these surfaces. Results A-XLPE inserts had higher rates of burnishing and lower rates of pitting and scratching compared with XLPE. There were no differences in the density of crosslinking at loaded and unloaded regions. A-XLPE showed higher oxidation indices in the unloaded surface region compared with XLPE. There were no differences in the levels of oxidation in the loaded regions. Conclusion Retrieval analysis of A-XLPE did not reflect a clinically relevant difference in surface damage, density of crosslinking, or oxidation compared with XLPE tibial inserts at short-term evaluation. Cite this article: Bone Joint J 2018;100-B:1330–5.
Collapse
|
12
|
Achieving More Natural Motion, Stability, and Function With a Dual-Pivot ACL-substituting Total Knee Arthroplasty Design. Tech Orthop 2018. [DOI: 10.1097/bto.0000000000000274] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
13
|
Brockett CL, Carbone S, Fisher J, Jennings LM. Influence of conformity on the wear of total knee replacement: An experimental study. Proc Inst Mech Eng H 2018; 232:127-134. [PMID: 29251167 PMCID: PMC5808816 DOI: 10.1177/0954411917746433] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Accepted: 10/26/2017] [Indexed: 11/21/2022]
Abstract
Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection.
Collapse
Affiliation(s)
- Claire L Brockett
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Silvia Carbone
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - John Fisher
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Louise M Jennings
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
14
|
Brown TS, Van Citters DW, Berry DJ, Abdel MP. The use of highly crosslinked polyethylene in total knee arthroplasty. Bone Joint J 2017; 99-B:996-1002. [PMID: 28768774 DOI: 10.1302/0301-620x.99b8.bjj-2017-0028.r1] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Accepted: 03/28/2017] [Indexed: 01/13/2023]
Abstract
Advances in polyethylene (PE) in total hip arthroplasty have led to interest and increased use of highly crosslinked PE (HXLPE) in total knee arthroplasty (TKA). Biomechanical data suggest improved wear characteristics for HXLPE inserts over conventional PE in TKA. Short-term results from registry data and few clinical trials are promising. Our aim is to present a review of the history of HXLPEs, the use of HXLPE inserts in TKA, concerns regarding potential mechanical complications, and a thorough review of the available biomechanical and clinical data. Cite this article: Bone Joint J 2017;99-B:996-1002.
Collapse
Affiliation(s)
- T S Brown
- Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA
| | - D W Van Citters
- Dartmouth College, 14 Engineering Drive, Hanover, NH 03755, USA
| | - D J Berry
- Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA
| | - M P Abdel
- Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA
| |
Collapse
|
15
|
Bracco P, Bellare A, Bistolfi A, Affatato S. Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review. MATERIALS (BASEL, SWITZERLAND) 2017; 10:E791. [PMID: 28773153 PMCID: PMC5551834 DOI: 10.3390/ma10070791] [Citation(s) in RCA: 75] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Revised: 07/06/2017] [Accepted: 07/08/2017] [Indexed: 01/03/2023]
Abstract
Ultra-high molecular weight polyethylene (UHMWPE) is the most common bearing material in total joint arthroplasty due to its unique combination of superior mechanical properties and wear resistance over other polymers. A great deal of research in recent decades has focused on further improving its performances, in order to provide durable implants in young and active patients. From "historical", gamma-air sterilized polyethylenes, to the so-called first and second generation of highly crosslinked materials, a variety of different formulations have progressively appeared in the market. This paper reviews the structure-properties relationship of these materials, with a particular emphasis on the in vitro and in vivo wear performances, through an analysis of the existing literature.
Collapse
Affiliation(s)
- Pierangiola Bracco
- Department of Chemistry and NIS (Nanostructured Interfaces and Surfaces) Center, University of Torino, 10125 Torino, Italy.
| | - Anuj Bellare
- Department of Orthopedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | | | - Saverio Affatato
- Medical Technology Laboratory, Rizzoli Orthopaedic Institute, 40136 Bologna, Italy.
| |
Collapse
|
16
|
Gigante A, Bottegoni C, Ragone V, Banci L. Effectiveness of Vitamin-E-Doped Polyethylene in Joint Replacement: A Literature Review. J Funct Biomater 2015; 6:889-900. [PMID: 26371052 PMCID: PMC4598683 DOI: 10.3390/jfb6030889] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 07/24/2015] [Accepted: 08/08/2015] [Indexed: 12/25/2022] Open
Abstract
Since polyethylene is one of the most frequently used biomaterials, such as in bearing components in joint arthroplasty, strong efforts have been made to improve the design and material properties over the last decades. Antioxidants, such as vitamin-E, seem to be a promising alternative to further increase durability and reduce polyethylene wear and degradation in the long-term. Nevertheless, even if several promising in vitro results are available, there is yet no clinical evidence that vitamin-E polyethylenes show these advantages in vivo. The aim of this paper was to provide a comprehensive overview on the current knowledge regarding the biological and mechanical proprieties of this biomaterial, underlying the in vitro and in vivo evidence for effectiveness of vitamin-E-doped polyethylene in joint arthroplasty.
Collapse
Affiliation(s)
- Antonio Gigante
- Clinical Orthopaedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, via Tronto 10/A, 60126 Ancona, Italy.
| | - Carlo Bottegoni
- Clinical Orthopaedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, via Tronto 10/A, 60126 Ancona, Italy.
| | - Vincenza Ragone
- Research and Development Department, Permedica S.p.A., via Como 38, 23807 Merate (LC), Italy.
| | - Lorenzo Banci
- Research and Development Department, Permedica S.p.A., via Como 38, 23807 Merate (LC), Italy.
| |
Collapse
|
17
|
CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities. BIOMED RESEARCH INTERNATIONAL 2014; 2014:567374. [PMID: 25506594 PMCID: PMC4258372 DOI: 10.1155/2014/567374] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2014] [Revised: 09/15/2014] [Accepted: 09/28/2014] [Indexed: 11/18/2022]
Abstract
The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.
Collapse
|
18
|
Definition and evaluation of testing scenarios for knee wear simulation under conditions of highly demanding daily activities. Med Eng Phys 2013; 35:591-600. [DOI: 10.1016/j.medengphy.2012.07.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2011] [Revised: 06/19/2012] [Accepted: 07/09/2012] [Indexed: 11/24/2022]
|
19
|
Tikhilov RM, Kornilov NN, Kulyaba TA, Saraev AV, Ignatenko VL. MODERN TRENDS IN ORTHOPEDICS: THE KNEE ARTHROPLASTY. TRAUMATOLOGY AND ORTHOPEDICS OF RUSSIA 2012. [DOI: 10.21823/2311-2905-2012--2-5-15] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2023]
Abstract
Using PubMed the authors analyzed publications dedicated to knee arthroplasty that were published in 2011. The modern trends of knee joint replacement include improvement of implants and instruments; partial knee replacement as alternative to TKA; reducing of surgical trauma due to less-invasive approaches; achieving of deep flexion after TKA; using of computer navigation and individual cutting blocks to make surgery more precise; optimization of rehabilitation process in pre-, intra-and postoperative period; including multimodal pain control; development of complex strategies for prevention of intra- and postoperative complications. In this review the attention was attracted to the most discussed in 2011 subjects: development of new designs and materials of knee implants; navigation, robotics and individualized resection blocks; partial knee replacement; infection, blood loss and venous thromboembolism after TKA; influence of different factors on arthroplasty outcomes, especially components and leg alignment, patella resurfacing, PCL retention or substitution, uncemented fixation, mobility of PE insert, severe pre-op deformities or stiffness, previous intra-articular fractures and tibia or femur osteotomies, soft tissue deficit etc.
Collapse
|
20
|
Halder A, Kutzner I, Graichen F, Heinlein B, Beier A, Bergmann G. Influence of limb alignment on mediolateral loading in total knee replacement: in vivo measurements in five patients. J Bone Joint Surg Am 2012; 94:1023-9. [PMID: 22637208 DOI: 10.2106/jbjs.k.00927] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Malalignment after total knee replacement could cause overloading of the implant bearing as well as of the bone itself, leading to osteolysis and early loosening. To quantify the stresses the implant has to withstand and to define a safe zone of limb alignment, the total contact forces as well as their mediolateral distribution have to be determined. Analytical gait data and mathematical models have been used for this purpose. We performed this study to determine in vivo loads of five patients after implantation of an instrumented tibial baseplate. METHODS Five patients with osteoarthritis of the knee received total knee replacement. The tibial component was instrumented with strain gauges for the measurement of three forces and three moments. The signals from the gauges were transferred telemetrically to an external receiver. At twelve months after surgery, postoperative measurements were obtained with the patients walking at a self-selected comfortable speed across a level walkway. Peak axial and medial forces of fifteen to twenty gait cycles were averaged and reported as a percent of individual body weight. RESULTS During the stance phase of the gait cycle, two maxima of the axial force occurred. Typical values were 215% of body weight at the first peak and 266% of body weight at the second peak. The medial load share was typically 73% at the first axial force peak and 65% at the second axial force peak. Analysis of inter-individual variations revealed a linear correlation with limb alignment. A deviation of 1° varus from neutral alignment increased the medial load share by 5%. CONCLUSIONS Consistent with the results of previous studies, we found that the force transferred by the medial compartment was usually greater than that transferred by the lateral compartment. Concerning the design of total knee replacements, an asymmetric tibial component with a larger medial contact area could possibly reduce peak contact stress on the bone and improve fixation of the implant. Mediolateral load distribution was quantified and correlated with limb alignment, thereby permitting the effects of malalignment after total knee replacement to be estimated.
Collapse
Affiliation(s)
- Andreas Halder
- Klinik für Endoprothetik, Sana Kliniken Sommerfeld, Waldhausstrasse 44, 16766 Sommerfeld, Germany.
| | | | | | | | | | | |
Collapse
|