1
|
Recent advances in surface plasmon resonance imaging and biological applications. Talanta 2023; 255:124213. [PMID: 36584617 DOI: 10.1016/j.talanta.2022.124213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 12/19/2022] [Accepted: 12/20/2022] [Indexed: 12/28/2022]
Abstract
Surface Plasmon Resonance Imaging (SPRI) is a robust technique for visualizing refractive index changes, which enables researchers to observe interactions between nanoscale objects in an imaging manner. In the past period, scholars have been attracted by the Prism-Coupled and Non-prism Coupled configurations of SPRI and have published numerous experimental results. This review describes the principle of SPRI and discusses recent developments in Prism-Coupled and Non-prism Coupled SPRI techniques in detail, respectively. And then, major advances in biological applications of SPRI are reviewed, including four sub-fields (cells, viruses, bacteria, exosomes, and biomolecules). The purpose is to briefly summarize the recent advances of SPRI and provide an outlook on the development of SPRI in various fields.
Collapse
|
2
|
Zhou P, Ding L, Yan Y, Wang Y, Su B. Recent advances in label-free imaging of cell-matrix adhesions. Chem Commun (Camb) 2023; 59:2341-2351. [PMID: 36744880 DOI: 10.1039/d2cc06499e] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Cell-matrix adhesions play an essential role in mediating and regulating many biological processes. The adhesion receptors, typically transmembrane integrins, provide dynamic correlations between intracellular environments and extracellular matrixes (ECMs) by bi-directional signaling. In-depth investigations of cell-matrix adhesion and integrin-mediated cell adhesive force are of great significance in biology and medicine. The emergence of advanced imaging techniques and principles has facilitated the understanding of the molecular composition and structure dynamics of cell-matrix adhesions, especially the label-free imaging methods that can be used to study living cell dynamics without immunofluorescence staining. This highlight article aims to give an overview of recent developments in imaging cell-matrix adhesions in a label-free manner. Electrochemiluminescence microscopy (ECLM) and surface plasmon resonance microscopy (SPRM) are briefly introduced and their applications in imaging analysis of cell-matrix adhesions are summarized. Then we highlight the advances in mapping cell-matrix adhesion force based on molecular tension probes and fluorescence microscopy (collectively termed as MTFM). The biomaterials including polyethylene glycol (PEG), peptides and DNA for constructing tension probes in MTFM are summarized. Finally, the outlook and perspectives on the further developments of cell-matrix adhesion imaging are presented.
Collapse
Affiliation(s)
- Ping Zhou
- Key Laboratory of Excited-State Materials of Zhejiang Province, Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| | - Lurong Ding
- Key Laboratory of Excited-State Materials of Zhejiang Province, Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| | - Yajuan Yan
- Key Laboratory of Excited-State Materials of Zhejiang Province, Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| | - Yafeng Wang
- Key Laboratory of Excited-State Materials of Zhejiang Province, Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| | - Bin Su
- Key Laboratory of Excited-State Materials of Zhejiang Province, Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
3
|
Tontarawongsa S, Visitsattapongse S, Pechprasarn S. Analysis of the surface plasmon resonance interferometric imaging performance of scanning confocal surface plasmon microscopy. BIOMEDICAL OPTICS EXPRESS 2022; 13:485-501. [PMID: 35154887 PMCID: PMC8803038 DOI: 10.1364/boe.448085] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 12/08/2021] [Accepted: 12/08/2021] [Indexed: 05/03/2023]
Abstract
Here, we apply rigorous coupled-wave theory to analyze the optical phase imaging performance of scanning confocal surface plasmon microscope. The scanning confocal surface plasmon resonance microscope is an embedded interferometric microscope interfering between two integrated optical beams. One beam is provided by the central part around the normal incident angle of the back focal plane, and the other beam is the incident angles beyond the critical angle, exciting the surface plasmon. Furthermore, the two beams can form an interference signal inside a confocal pinhole in the image plane, which provides a well-defined path for the surface plasmon propagation. The scanning confocal surface plasmon resonance microscope operates by scanning the sample along the optical axis z, so-called V(z). The study investigates two imaging modes: non-quantitative imaging and quantitative imaging modes. We also propose a theoretical framework to analyze the scanning confocal surface plasmon resonance microscope compared to non-interferometric surface plasmon microscopes and quantify quantitative performance parameters including spatial resolution and optical contrast for non-quantitative imaging; sensitivity and crosstalk for quantitative imaging. The scanning confocal SPR microscope can provide a higher spatial resolution, better sensitivity, and lower crosstalk measurement. The confocal SPR microscope configuration is a strong candidate for high throughput measurements since it requires a smaller sensing channel than the other SPR microscopes.
Collapse
Affiliation(s)
- Sorawit Tontarawongsa
- Department of Biomedical Engineering, School of Engineering, King Mongkut's Institute of Technology, Ladkrabang, Bangkok 10520, Thailand
| | - Sarinporn Visitsattapongse
- Department of Biomedical Engineering, School of Engineering, King Mongkut's Institute of Technology, Ladkrabang, Bangkok 10520, Thailand
| | - Suejit Pechprasarn
- College of Biomedical Engineering, Rangsit University, Pathum Thani 12000, Thailand
| |
Collapse
|
4
|
Zhang P, Zhou X, Wang R, Jiang J, Wan Z, Wang S. Label-Free Imaging of Nanoscale Displacements and Free-Energy Profiles of Focal Adhesions with Plasmonic Scattering Microscopy. ACS Sens 2021; 6:4244-4254. [PMID: 34711049 PMCID: PMC8638434 DOI: 10.1021/acssensors.1c01938] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Cell adhesion plays a critical role in cell communication, cell migration, cell proliferation, and integration of medical implants with tissues. Focal adhesions physically link the cell cytoskeleton to the extracellular matrix, but it remains challenging to image single focal adhesions directly. Here, we show that plasmonic scattering microscopy (PSM) can directly image the single focal adhesions in a label-free, real-time, and non-invasive manner with sub-micrometer spatial resolution. PSM is developed based on surface plasmon resonance (SPR) microscopy, and the evanescent illumination makes it immune to the interference of intracellular structures. Unlike the conventional SPR microscopy, PSM can provide a high signal-to-noise ratio and sub-micrometer spatial resolution for imaging the analytes with size down to a single-molecule level, thus allowing both the super-resolution lateral localization for measuring the nanoscale displacement and precise tracking of vertical distances between the analyte centroid and the sensor surface for analysis of free-energy profiles. PSM imaging of the RBL-2H3 cell with temporal resolution down to microseconds shows that the focal adhesions have random diffusion behaviors in addition to their directional movements during the antibody-mediated activation process. The free-energy mapping also shows a similar movement tendency, indicating that the cell may change its morphology upon varying the binding conditions of adhesive structures. PSM provides insights into the individual focal adhesion activities and can also serve as a promising tool for investigating the cell/surface interactions, such as cell capture and detection and tissue adhesive materials screening.
Collapse
Affiliation(s)
- Pengfei Zhang
- Biodesign Center for Bioelectronics and Biosensors, Arizona State University, Tempe, Arizona 85287, USA
| | - Xinyu Zhou
- Biodesign Center for Bioelectronics and Biosensors, Arizona State University, Tempe, Arizona 85287, USA
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona 85287, USA
| | - Rui Wang
- Biodesign Center for Bioelectronics and Biosensors, Arizona State University, Tempe, Arizona 85287, USA
| | - Jiapei Jiang
- Biodesign Center for Bioelectronics and Biosensors, Arizona State University, Tempe, Arizona 85287, USA
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona 85287, USA
| | - Zijian Wan
- Biodesign Center for Bioelectronics and Biosensors, Arizona State University, Tempe, Arizona 85287, USA
- School of Electrical, Energy and Computer Engineering, Arizona State University, Tempe, Arizona 85287, USA
| | - Shaopeng Wang
- Biodesign Center for Bioelectronics and Biosensors, Arizona State University, Tempe, Arizona 85287, USA
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona 85287, USA
| |
Collapse
|
5
|
Real-time and wide-field mapping of cell-substrate adhesion gap and its evolution via surface plasmon resonance holographic microscopy. Biosens Bioelectron 2021; 174:112826. [PMID: 33262060 DOI: 10.1016/j.bios.2020.112826] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 10/17/2020] [Accepted: 11/14/2020] [Indexed: 12/11/2022]
Abstract
As one of the most common biological phenomena, cell adhesion plays a vital role in the cellular activities such as the growth and apoptosis, attracting tremendous research interests over the past decades. Taking the cell evolution under drug injection as an example, the dynamics of cell-substrate adhesion gap can provide valuable information in the fundamental research of cell contacts. A robust technique of monitoring the cell adhesion gap and its evolution in real time is highly desired. Herein, we develop a surface plasmon resonance holographic microscopy to achieve the novel functionality of real-time and wide-field mapping of the cell-substrate adhesion gap and its evolution in situ. The cell adhesion gap images of mouse osteoblast cells and human breast cancer cells have been effectively extracted in a dynamic and label-free manner. The proposed technique opens up a new avenue of revealing the cell-substrate interaction mechanism and renders the wide applications in the biosensing area.
Collapse
|
6
|
Son T, Lee C, Moon G, Lee D, Cheong E, Kim D. Enhanced surface plasmon microscopy based on multi-channel spatial light switching for label-free neuronal imaging. Biosens Bioelectron 2019; 146:111738. [PMID: 31600626 DOI: 10.1016/j.bios.2019.111738] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 09/27/2019] [Indexed: 02/04/2023]
Abstract
In this paper, we have investigated multi-channel switching of light incidence in multiple directions to improve image clarity in surface plasmon microscopy (SPM) for robust and consistent imaging performance regardless of the pattern geometry and shape. Multi-channel light switching in SPM allows significant reduction of adverse scattering effects by surface plasmon (SP). For proof of concept, an eight-channel spatially switched SPM (ssSPM) system has been set up. The results with reference objects including square arrays and Siemens stars experimentally confirm much improved images with ssSPM by reducing the artifacts of SP scattering significantly. On a quantitative basis, contrast analysis preformed with square arrays shows image contrast enhanced by more than three times over conventional SPM. Three image reconstruction algorithms were evaluated for optimal image acquisition. It is suggested that averaging combined with minimum-filtering produces the highest resolution. ssSPM was applied to label-free imaging of primary neuron cultures and shown to present enhanced images with clarity far better than conventional SPM.
Collapse
Affiliation(s)
- Taehwang Son
- School of Electrical and Electronic Engineering, Yonsei University, Seoul, 03722, South Korea
| | - Changhun Lee
- School of Electrical and Electronic Engineering, Yonsei University, Seoul, 03722, South Korea
| | - Gwiyeong Moon
- School of Electrical and Electronic Engineering, Yonsei University, Seoul, 03722, South Korea
| | - Dongsu Lee
- Department of Biotechnology, Yonsei University, Seoul, 03722, South Korea
| | - Eunji Cheong
- Department of Biotechnology, Yonsei University, Seoul, 03722, South Korea
| | - Donghyun Kim
- School of Electrical and Electronic Engineering, Yonsei University, Seoul, 03722, South Korea.
| |
Collapse
|
7
|
Gao J, Wo X, Wang Y, Li M, Zhou C, Wang W. Postrecording Pixel-Reconstruction Approach for Correcting the Lateral Drifts in Surface Plasmon Resonance Microscope. Anal Chem 2019; 91:13620-13626. [PMID: 31612709 DOI: 10.1021/acs.analchem.9b02804] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Surface plasmon resonance microscope (SPRM) sample stage inevitably suffers from lateral drifts as a result of many environmental factors including thermal fluctuation, mechanical vibration, and relaxation. It places great obstacles to time-lapsed imaging and measurements that need high spatial resolution or long recording time. Existing solutions often require experimental efforts such as the addition of optical markers together with piezoelectric stage-based active feedback configurations. Herein, we propose an all-digital, postrecording image-processing method to remove the lateral drift in a series of time-lapsed SPRM images. The method first calculates the value of lateral drift at subpixel accuracy by combining image cross-correlation analysis and superlocalization strategy. It subsequently reconstructed the drift-free image sequences in a pixel-by-pixel and frame-by-frame manner, according to the linear decomposition and reconstruction principle. This method purely relies on image processing, and it does not require any experimental efforts or hardware. In addition to SPRM, we further demonstrated the applicability of the present method in other types of optical imaging techniques including bright-field transmission microscope and dark-field scattering microscope.
Collapse
Affiliation(s)
- Jia Gao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Xiang Wo
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Yongjie Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Minghe Li
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Chunyuan Zhou
- Nikon Instruments (Shanghai) Co., Ltd. , Shanghai 200120 , P. R. China
| | - Wei Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| |
Collapse
|
8
|
Banville FA, Moreau J, Chabot K, Cattoni A, Fröhlich U, Bryche JF, Collin S, Charette PG, Grandbois M, Canva M. Nanoplasmonics-enhanced label-free imaging of endothelial cell monolayer integrity. Biosens Bioelectron 2019; 141:111478. [PMID: 31280004 DOI: 10.1016/j.bios.2019.111478] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 06/21/2019] [Accepted: 06/24/2019] [Indexed: 01/24/2023]
Abstract
Surface plasmon resonance imaging (SPRI) is a powerful label-free imaging modality for the analysis of morphological dynamics in cell monolayers. However, classical plasmonic imaging systems have relatively poor spatial resolution along one axis due to the plasmon mode attenuation distance (tens of μm, typically), which significantly limits their ability to resolve subcellular structures. We address this limitation by adding an array of nanostructures onto the metal sensing surface (25 nm thick, 200 nm width, 400 nm period grating) to couple localized plasmons with propagating plasmons, thereby reducing attenuation length and commensurately increasing spatial imaging resolution, without significant loss of sensitivity or image contrast. In this work, experimental results obtained with both conventional unstructured and nanostructured gold film SPRI sensor chips show a clear gain in spatial resolution achieved with surface nanostructuring. The work demonstrates the ability of the nanostructured SPRI chips to resolve fine morphological detail (intercellular gaps) in experiments monitoring changes in endothelial cell monolayer integrity following the activation of the cell surface protease-activated receptor 1 (PAR1) by thrombin. In particular, the nanostructured chips reveal the persistence of small intercellular gaps (<5 μm2) well after apparent recovery of cell monolayer integrity as determined by conventional unstructured surface based SPRI. This new high spatial resolution plasmonic imaging technique uses low-cost and reusable patterned substrates and is likely to find applications in cell biology and pharmacology by allowing label-free quantification of minute cell morphological activities associated with receptor dependent intracellular signaling activity.
Collapse
Affiliation(s)
- Frederic A Banville
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Laboratoire Charles Fabry (LCF), Institut d'Optique Graduate School, Université Paris-Saclay, CNRS, Palaiseau, 91127, France
| | - Julien Moreau
- Laboratoire Charles Fabry (LCF), Institut d'Optique Graduate School, Université Paris-Saclay, CNRS, Palaiseau, 91127, France
| | - Kevin Chabot
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada
| | - Andrea Cattoni
- Centre de Nanosciences et de Nanotechnologies (C2N), CNRS UMR-9001, Université Paris-Sud/Paris-Saclay, Palaiseau, 91120, France
| | - Ulrike Fröhlich
- Département de Pharmacologie et Physiologie, Institut de Pharmacologie de Sherbrooke (IPS), Université de Sherbrooke, Canada
| | - Jean-François Bryche
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada
| | - Stéphane Collin
- Centre de Nanosciences et de Nanotechnologies (C2N), CNRS UMR-9001, Université Paris-Sud/Paris-Saclay, Palaiseau, 91120, France
| | - Paul G Charette
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada
| | - Michel Grandbois
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Département de Pharmacologie et Physiologie, Institut de Pharmacologie de Sherbrooke (IPS), Université de Sherbrooke, Canada
| | - Michael Canva
- Laboratoire Nanotechnologies Nanosystèmes (LN2), CNRS UMI-3463, Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, Sherbrooke, J1K 0A5, Canada; Laboratoire Charles Fabry (LCF), Institut d'Optique Graduate School, Université Paris-Saclay, CNRS, Palaiseau, 91127, France.
| |
Collapse
|
9
|
Rubin S, Hong B, Fainman Y. Subnanometer imaging and controlled dynamical patterning of thermocapillary driven deformation of thin liquid films. LIGHT, SCIENCE & APPLICATIONS 2019; 8:77. [PMID: 31645923 PMCID: PMC6804570 DOI: 10.1038/s41377-019-0190-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 08/01/2019] [Accepted: 08/05/2019] [Indexed: 06/01/2023]
Abstract
Exploring and controlling the physical factors that determine the topography of thin liquid dielectric films are of interest in manifold fields of research in physics, applied mathematics, and engineering and have been a key aspect of many technological advancements. Visualization of thin liquid dielectric film topography and local thickness measurements are essential tools for characterizing and interpreting the underlying processes. However, achieving high sensitivity with respect to subnanometric changes in thickness via standard optical methods is challenging. We propose a combined imaging and optical patterning projection platform that is capable of optically inducing dynamical flows in thin liquid dielectric films and plasmonically resolving the resulting changes in topography and thickness. In particular, we employ the thermocapillary effect in fluids as a novel heat-based method to tune plasmonic resonances and visualize dynamical processes in thin liquid dielectric films. The presented results indicate that light-induced thermocapillary flows can form and translate droplets and create indentation patterns on demand in thin liquid dielectric films of subwavelength thickness and that plasmonic microscopy can image these fluid dynamical processes with a subnanometer sensitivity along the vertical direction.
Collapse
Affiliation(s)
- Shimon Rubin
- Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Dr., La Jolla, CA 92023 USA
| | - Brandon Hong
- Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Dr., La Jolla, CA 92023 USA
| | - Yeshaiahu Fainman
- Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Dr., La Jolla, CA 92023 USA
| |
Collapse
|
10
|
Bocková M, Slabý J, Špringer T, Homola J. Advances in Surface Plasmon Resonance Imaging and Microscopy and Their Biological Applications. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:151-176. [PMID: 30822102 DOI: 10.1146/annurev-anchem-061318-115106] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Surface plasmon resonance microscopy and imaging are optical methods that enable observation and quantification of interactions of nano- and microscale objects near a metal surface in a temporally and spatially resolved manner. This review describes the principles of surface plasmon resonance microscopy and imaging and discusses recent advances in these methods, in particular, in optical platforms and functional coatings. In addition, the biological applications of these methods are reviewed. These include the detection of a broad variety of analytes (nucleic acids, proteins, bacteria), the investigation of biological systems (bacteria and cells), and biomolecular interactions (drug-receptor, protein-protein, protein-DNA, protein-cell).
Collapse
Affiliation(s)
- Markéta Bocková
- Institute of Photonics and Electronics, Czech Academy of Sciences, 18251 Prague, Czech Republic;
| | - Jiří Slabý
- Institute of Photonics and Electronics, Czech Academy of Sciences, 18251 Prague, Czech Republic;
| | - Tomáš Špringer
- Institute of Photonics and Electronics, Czech Academy of Sciences, 18251 Prague, Czech Republic;
| | - Jiří Homola
- Institute of Photonics and Electronics, Czech Academy of Sciences, 18251 Prague, Czech Republic;
| |
Collapse
|
11
|
Hassani H, Kreysing E. Noninvasive measurement of the refractive index of cell organelles using surface plasmon resonance microscopy. OPTICS LETTERS 2019; 44:1359-1362. [PMID: 30874650 DOI: 10.1364/ol.44.001359] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Accepted: 02/09/2019] [Indexed: 06/09/2023]
Abstract
The health of a eukaryotic cell depends on the proper functioning of its cell organelles. Characterizing these nanometer- to micrometer-scaled specialized subunits without disturbing the cell is challenging but can also provide valuable insights regarding the state of a cell. We show that objective-based scanning surface plasmon resonance microscopy can be used to analyze the refractive index of cell organelles quantitatively in a noninvasive and label-free manner with a lateral resolution at the diffraction limit.
Collapse
|
12
|
Kreysing E, Hassani H, Hampe N, Offenhäusser A. Nanometer-Resolved Mapping of Cell-Substrate Distances of Contracting Cardiomyocytes Using Surface Plasmon Resonance Microscopy. ACS NANO 2018; 12:8934-8942. [PMID: 30180539 DOI: 10.1021/acsnano.8b01396] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
It has been shown that quantitative measurements of the cell-substrate distance of steady cells are possible with scanning surface plasmon resonance microscopy setups in combination with an angle resolved analysis. However, the accuracy of the determined cell-substrate distances as well as the capabilities for the investigation of cell dynamics remained limited due to the assumption of a homogeneous refractive index of the cytosol. Strong spatial or temporal deviations between the local refractive index and the average value can result in errors in the calculated cell-substrate distance of around 100 nm, while the average accuracy was determined to 37 nm. Here, we present a combination of acquisition and analysis techniques that enables the measurement of the cell-substrate distance of contractile cells as well as the study of intracellular processes through changes in the refractive index at the diffraction limit. By decoupling the measurement of the cell-substrate distance and the refractive index of the cytoplasm, we could increase the accuracy of the distance measurement on average by a factor of 25 reaching 1.5 nm under ideal conditions. We show a temporal and spatial mapping of changes in the refractive index and the cell-substrate distance which strongly correlate with the action potentials and reconstruct the three-dimensional profile of the basal cell membrane and its dynamics, while we reached an actual measurement accuracy of 2.3 nm.
Collapse
|
13
|
Jiang Y, Wang W. Point Spread Function of Objective-Based Surface Plasmon Resonance Microscopy. Anal Chem 2018; 90:9650-9656. [PMID: 29965733 DOI: 10.1021/acs.analchem.8b02800] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Objective-based surface plasmon resonance microscopy (SPRM) is a novel optical imaging technique that can map the spatial distribution of a local refractive index based on propagating surface plasmon polaritons (SPPs). Different from some other optical microscopy that shows a dot-like point spread function (PSF), a nanosized object appears as a wave-like pattern containing parabolic tails in SPRM. The geometrical complexity of the wave-like pattern hampered the quantitative interpretation of the PSF of SPRM. Previous studies have shown that two adjacent rings were obtained in the frequency domain by applying a two-dimensional Fourier transform to such patterns. In the present work, a ring-fitting method was developed to extract geometrical features out of the dual rings and to connect these features with several experimental parameters. It was found that the radius of ring equaled to the wavevector of SPPs. Its orientation revealed the propagation direction of SPPs. The coordinate distance of the center of ring gave the parallel component of the wavevector of the incident light, which was regulated by the incident angle. The ring-broadening factor reflected the propagation length of SPPs in a reciprocal relationship. Systematical and quantitative interpretations in the frequency domain not only advanced the basic understanding on the PSF of SPRM but also opened up the possibility to utilize these frequency-domain features for detection and sensing purposes in future.
Collapse
Affiliation(s)
- Yingyan Jiang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210093 , China
| | - Wei Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210093 , China
| |
Collapse
|
14
|
Su YW, Wang W. Surface plasmon resonance sensing: from purified biomolecules to intact cells. Anal Bioanal Chem 2018; 410:3943-3951. [DOI: 10.1007/s00216-018-1008-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2018] [Revised: 02/03/2018] [Accepted: 03/07/2018] [Indexed: 12/11/2022]
|
15
|
Son T, Lee C, Seo J, Choi IH, Kim D. Surface plasmon microscopy by spatial light switching for label-free imaging with enhanced resolution. OPTICS LETTERS 2018; 43:959-962. [PMID: 29444037 DOI: 10.1364/ol.43.000959] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Accepted: 01/10/2018] [Indexed: 05/20/2023]
Abstract
In this Letter, we describe spatially switched surface plasmon microscopy (ssSPM) based on two-channel momentum sampling. The performance evaluated with periodic nanowires in comparison with conventional SPM and bright-field microscopy shows that the resolution of ssSPM is enhanced by almost 15 times over conventional SPM. ssSPM provides an extremely simple way to attain diffraction limit in SPM and to go beyond for super-resolution in label-free microscopy techniques.
Collapse
|
16
|
Yu H, Shan X, Wang S, Tao N. Achieving High Spatial Resolution Surface Plasmon Resonance Microscopy with Image Reconstruction. Anal Chem 2017; 89:2704-2707. [DOI: 10.1021/acs.analchem.6b05049] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Hui Yu
- State
Key Laboratory of Analytical Chemistry for Life Science, School of
Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
- Center
for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Xiaonan Shan
- Center
for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Shaopeng Wang
- Center
for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Nongjian Tao
- State
Key Laboratory of Analytical Chemistry for Life Science, School of
Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
- Center
for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| |
Collapse
|
17
|
Hackett LP, Seo S, Kim S, Goddard LL, Liu GL. Label-free cell-substrate adhesion imaging on plasmonic nanocup arrays. BIOMEDICAL OPTICS EXPRESS 2017; 8:1139-1151. [PMID: 28271009 PMCID: PMC5330562 DOI: 10.1364/boe.8.001139] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Revised: 12/07/2016] [Accepted: 12/19/2016] [Indexed: 05/10/2023]
Abstract
Cell adhesion is a crucial biological and biomedical parameter defining cell differentiation, cell migration, cell survival, and state of disease. Because of its importance in cellular function, several tools have been developed in order to monitor cell adhesion in response to various biochemical and mechanical cues. However, there remains a need to monitor cell adhesion and cell-substrate separation with a method that allows real-time measurements on accessible equipment. In this article, we present a method to monitor cell-substrate separation at the single cell level using a plasmonic extraordinary optical transmission substrate, which has a high sensitivity to refractive index changes at the metal-dielectric interface. We show how refractive index changes can be detected using intensity peaks in color channel histograms from RGB images taken of the device surface with a brightfield microscope. This allows mapping of the nonuniform refractive index pattern of a single cell cultured on the plasmonic substrate and therefore high-throughput detection of cell-substrate adhesion with observations in real time.
Collapse
Affiliation(s)
- L. P. Hackett
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 306 N Wright St, Urbana, IL 61801, USA
- Miro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
| | - S. Seo
- Miro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
- Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, 1304 W Green St, Urbana, IL 61801, USA
| | - S. Kim
- Miro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, 1270 Digital Computer Laboratory, Urbana, IL 61801, USA
| | - L. L. Goddard
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 306 N Wright St, Urbana, IL 61801, USA
- Miro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
| | - G. L. Liu
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 306 N Wright St, Urbana, IL 61801, USA
- Miro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, 208 N Wright St, Urbana, IL 61801, USA
- School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 43007, China
| |
Collapse
|
18
|
Matsuura K, Sugimoto I, Kuroda Y, Kadowaki K, Matsusaki M, Akashi M. Development of Microfluidic Systems for Fabricating Cellular Multilayers. ANAL SCI 2016; 32:1171-1176. [PMID: 27829621 DOI: 10.2116/analsci.32.1171] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
We designed a microfluidic system comprising microfluidic channels, pumps, and valves to enable the fabrication of cellular multilayers in order to reduce labor inputs for coating extracellular matrices onto adhesive cells (e.g., centrifugation). Our system was used to fabricate nanometer-sized, layer-by-layer films of the extracellular matrices on a monolayer of C2C12 myoblasts. The use of this microfluidic system allowed the fabrication of cellular multilayers in designed microfluidic channels and on commercial culture dishes. The thickness of the fabricated multilayer using this microfluidic system was higher than that of the multilayer that was formed by centrifugation. Because cellular multilayer fabrication is less laborious and the mechanical force to the cell is reduced, this novel system can be applied to tissue modeling for cell biology studies, pharmaceutical assays, and quantitative analyses of mechanical or chemical stimuli applied to multilayers.
Collapse
Affiliation(s)
- Koji Matsuura
- Research Core for Interdisciplinary Sciences, Okayama University
| | | | | | | | | | | |
Collapse
|
19
|
Kong W, Du W, Liu K, Wang C, Liu L, Zhao Z, Luo X. Launching deep subwavelength bulk plasmon polaritons through hyperbolic metamaterials for surface imaging with a tuneable ultra-short illumination depth. NANOSCALE 2016; 8:17030-17038. [PMID: 27714023 DOI: 10.1039/c6nr03313j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Hyperbolic metamaterials (HMMs) composed of multiple nanometal-dielectric films are proposed for launching deep subwavelength bulk plasmon polaritons (BPPs) as uniform, large area surface imaging illumination sources with a skin depth even beyond 10 nm. Benefiting from the coupled plasmon modes over a wide wavevector range in HMMs, the illumination depth could be continually tuned, simply by adjusting the incidence angle of light impinged on a grating structure for BPP excitation. As an example, the illumination depths of 19-63 nm at a light wavelength of 532 nm are demonstrated with SiO2-Ag multifilms. Moreover, the structure holds its deep subwavelength illumination depth for a broad light wavelength range, resembling that of light total internal reflection in a prism with an ultra high refractive index. Furthermore, a fluorescent nanoparticle based micro-zone system was employed for estimating the illumination depth of the HMM structure. The method is believed to provide access for surface imaging features in ultra thin layers especially for bio-samples.
Collapse
Affiliation(s)
- Weijie Kong
- State Key Laboratory of Optical Technologies on Nano-Fabrication and Micro-Engineering, Institute of Optics and Electronics, Chinese Academy of Science, P.O. Box 350, Chengdu 610209, China.
| | - Wenjuan Du
- State Key Laboratory of Optical Technologies on Nano-Fabrication and Micro-Engineering, Institute of Optics and Electronics, Chinese Academy of Science, P.O. Box 350, Chengdu 610209, China. and University of Chinese Academy of Sciences, Beijing 100049, China
| | - Kaipeng Liu
- State Key Laboratory of Optical Technologies on Nano-Fabrication and Micro-Engineering, Institute of Optics and Electronics, Chinese Academy of Science, P.O. Box 350, Chengdu 610209, China.
| | - Changtao Wang
- State Key Laboratory of Optical Technologies on Nano-Fabrication and Micro-Engineering, Institute of Optics and Electronics, Chinese Academy of Science, P.O. Box 350, Chengdu 610209, China.
| | - Ling Liu
- State Key Laboratory of Optical Technologies on Nano-Fabrication and Micro-Engineering, Institute of Optics and Electronics, Chinese Academy of Science, P.O. Box 350, Chengdu 610209, China.
| | - Zeyu Zhao
- State Key Laboratory of Optical Technologies on Nano-Fabrication and Micro-Engineering, Institute of Optics and Electronics, Chinese Academy of Science, P.O. Box 350, Chengdu 610209, China.
| | - Xiangang Luo
- State Key Laboratory of Optical Technologies on Nano-Fabrication and Micro-Engineering, Institute of Optics and Electronics, Chinese Academy of Science, P.O. Box 350, Chengdu 610209, China.
| |
Collapse
|
20
|
Berguiga L, Streppa L, Boyer-Provera E, Martinez-Torres C, Schaeffer L, Elezgaray J, Arneodo A, Argoul F. Time-lapse scanning surface plasmon microscopy of living adherent cells with a radially polarized beam. APPLIED OPTICS 2016; 55:1216-27. [PMID: 26906571 DOI: 10.1364/ao.55.001216] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
We report on a fibered high-resolution scanning surface plasmon microscope for long term imaging of living adherent cells. The coupling of a high numerical aperture objective lens and a fibered heterodyne interferometer enhances both the sensitivity and the long term stability of this microscope, allowing for time-lapse recording over several days. The diffraction limit is reached with a radially polarized illumination beam. Adherence and motility of living C2C12 myoblast cells are followed for 50 h, revealing that the dynamics of these cells change after 10 h. This plasmon enhanced evanescent wave microscopy is particularly suited for investigating cell adhesion, since it can not only be performed without staining of the sample but it can also capture in real time the exchange of extracellular matrix elements between the substrate and the cells.
Collapse
|
21
|
Wei SC, Yang PT, Wu TH, Lu YL, Gu F, Sung KB, Lin CW. Characteristic investigation of scanning surface plasmon microscopy for nucleotide functionalized nanoarray. OPTICS EXPRESS 2015; 23:20104-20114. [PMID: 26367668 DOI: 10.1364/oe.23.020104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A calculation based on surface plasmon coupling condition and Maxwell-Garnett equation was performed for predicting the coupling angle shift and thin film thickness in scanning surface plasmon microscopy (SSPM). The refractive index sensitivity and lateral resolution of an SSPM system was also investigated. The limit of detection of angle shift was 0.01°, the limit of quantification of angle shift was 0.03°, and the sensitivity was around 0.12° shift per nm ZnO film when the film thickness was less than 22.6 nm. Two partially connected Au nano-discs with a center-to-center distance of 1.1 μm could be identified as two peaks. The system was applied to image nanostructure defects and a virus-probe functionalized nanoarray. We expect the potential application in nanobiosensors with further optimization in the future.
Collapse
|
22
|
Albers J, Toma K, Offenhäusser A. Engineering connectivity by multiscale micropatterning of individual populations of neurons. Biotechnol J 2015; 10:332-8. [DOI: 10.1002/biot.201400609] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2014] [Revised: 11/24/2014] [Accepted: 12/11/2014] [Indexed: 11/12/2022]
|
23
|
Toma K, Kano H, Offenhäusser A. Label-free measurement of cell-electrode cleft gap distance with high spatial resolution surface plasmon microscopy. ACS NANO 2014; 8:12612-9. [PMID: 25423587 DOI: 10.1021/nn505521e] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Understanding the interface between cells or tissues and artificial materials is of critical importance for a broad range of areas. For example, in neurotechnology, the interfaces between neurons and external devices create a link between technical and the nervous systems by stimulating or recording from neural tissue. Here, a more effective interface is required to enhance the electrical characteristics of neuronal recordings and stimulations. Up to now, the lack of a systematic characterization of cell-electrode interaction turns out to be the major bottleneck. In this work, we employed a recently developed surface plasmon microscope (SPM) to monitor in real-time the cell-metal interface and to measure in situ the gap distance of the cleft with the spatial resolution reaching to the optical diffraction limit. The SPM allowed determination of the distance of human embryonic kidney 293 cells cultured on gold surfaces coated with various peptides or proteins without any labeling. This method can dramatically simplify the interaction investigation at metal-living cell interface and should be incorporated into systematic characterization methods.
Collapse
Affiliation(s)
- Koji Toma
- Institute of Bioelectronics (ICS-8/PGI-8), Forschungszentrum Jülich GmbH , 52425 Jülich, Germany
| | | | | |
Collapse
|
24
|
Peterson AW, Halter M, Tona A, Plant AL. High resolution surface plasmon resonance imaging for single cells. BMC Cell Biol 2014; 15:35. [PMID: 25441447 PMCID: PMC4289309 DOI: 10.1186/1471-2121-15-35] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2014] [Accepted: 09/30/2014] [Indexed: 11/10/2022] Open
Abstract
Background Surface plasmon resonance imaging (SPRI) is a label-free technique that can image refractive index changes at an interface. We have previously used SPRI to study the dynamics of cell-substratum interactions. However, characterization of spatial resolution in 3 dimensions is necessary to quantitatively interpret SPR images. Spatial resolution is complicated by the asymmetric propagation length of surface plasmons in the x and y dimensions leading to image degradation in one direction. Inferring the distance of intracellular organelles and other subcellular features from the interface by SPRI is complicated by uncertainties regarding the detection of the evanescent wave decay into cells. This study provides an experimental basis for characterizing the resolution of an SPR imaging system in the lateral and distal dimensions and demonstrates a novel approach for resolving sub-micrometer cellular structures by SPRI. The SPRI resolution here is distinct in its ability to visualize subcellular structures that are in proximity to a surface, which is comparable with that of total internal reflection fluorescence (TIRF) microscopy but has the advantage of no fluorescent labels. Results An SPR imaging system was designed that uses a high numerical aperture objective lens to image cells and a digital light projector to pattern the angle of the incident excitation on the sample. Cellular components such as focal adhesions, nucleus, and cellular secretions are visualized. The point spread function of polymeric nanoparticle beads indicates near-diffraction limited spatial resolution. To characterize the z-axis response, we used micrometer scale polymeric beads with a refractive index similar to cells as reference materials to determine the detection limit of the SPR field as a function of distance from the substrate. Multi-wavelength measurements of these microspheres show that it is possible to tailor the effective depth of penetration of the evanescent wave into the cellular environment. Conclusion We describe how the use of patterned incident light provides SPRI at high spatial resolution, and we characterize a finite limit of detection for penetration depth. We demonstrate the application of a novel technique that allows unprecedented subcellular detail for SPRI, and enables a quantitative interpretation of SPRI for subcellular imaging. Electronic supplementary material The online version of this article (doi:10.1186/1471-2121-15-35) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Alexander W Peterson
- Biosystems and Biomaterials Division, National Institute of Standards and Technology, 100 Bureau Drive, Mail Stop 8313, Gaithersburg, MD 20899, USA.
| | | | | | | |
Collapse
|
25
|
Halpern AR, Wood JB, Wang Y, Corn RM. Single-nanoparticle near-infrared surface plasmon resonance microscopy for real-time measurements of DNA hybridization adsorption. ACS NANO 2014; 8:1022-1030. [PMID: 24350885 DOI: 10.1021/nn405868e] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A novel 814 nm near-infrared surface plasmon resonance (SPR) microscope is used for the real-time detection of the sequence-selective hybridization adsorption of single DNA-functionalized gold nanoparticles. The objective-coupled, high numerical aperture SPR microscope is capable of imaging in situ the adsorption of single polystyrene and gold particles with diameters ranging from 450 to 20 nm onto a 90 μm × 70 μm area of a gold thin film with a time resolution of approximately 1-3 s. Initial real-time SPR imaging (SPRI) measurements were performed to detect the accumulation of 40 nm gold nanoparticles for 10 min onto a gold thin film functionalized with a 100% complementary DNA surface at concentrations from 5 pM to 100 fM by counting individual particle binding events. A 100% noncomplementary DNA surface exhibited virtually no nanoparticle adsorption. In contrast, in a second set of SPRI measurements, two component complementary/noncomplementary mixed DNA monolayers that contained a very small percentage of complementary sequences ranging from 0.1 to 0.001%, showed both permanent and transient hybridization adsorption of the gold nanoparticles that could be tracked both temporally and spatially with the SPR microscope. These experiments demonstrate that SPR imaging measurements of single biofunctionalized nanoparticles can be incorporated into bioaffinity biosensing methods at subpicomolar concentrations.
Collapse
Affiliation(s)
- Aaron R Halpern
- Department of Chemistry, University of California-Irvine , Irvine, California 92697, United States
| | | | | | | |
Collapse
|