1
|
Sharma S, Kalyani N, Dutta T, Velázquez-González JS, Llamas-Garro I, Ung B, Bas J, Dubey R, Mishra SK. Optical Devices for the Diagnosis and Management of Spinal Cord Injuries: A Review. BIOSENSORS 2024; 14:296. [PMID: 38920599 PMCID: PMC11201428 DOI: 10.3390/bios14060296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 05/21/2024] [Accepted: 06/02/2024] [Indexed: 06/27/2024]
Abstract
Throughout the central nervous system, the spinal cord plays a very important role, namely, transmitting sensory and motor information inwardly so that it can be processed by the brain. There are many different ways this structure can be damaged, such as through traumatic injury or surgery, such as scoliosis correction, for instance. Consequently, damage may be caused to the nervous system as a result of this. There is no doubt that optical devices such as microscopes and cameras can have a significant impact on research, diagnosis, and treatment planning for patients with spinal cord injuries (SCIs). Additionally, these technologies contribute a great deal to our understanding of these injuries, and they are also essential in enhancing the quality of life of individuals with spinal cord injuries. Through increasingly powerful, accurate, and minimally invasive technologies that have been developed over the last decade or so, several new optical devices have been introduced that are capable of improving the accuracy of SCI diagnosis and treatment and promoting a better quality of life after surgery. We aim in this paper to present a timely overview of the various research fields that have been conducted on optical devices that can be used to diagnose spinal cord injuries as well as to manage the associated health complications that affected individuals may experience.
Collapse
Affiliation(s)
- Sonika Sharma
- Department of Physics, Graphic Era Hill University, Dehradun 248002, Uttarakhand, India;
| | - Neeti Kalyani
- Department of Biotechnology and Biomedicine, Denmark Technical University, 2800 Kongens Lyngby, Denmark;
| | - Taposhree Dutta
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Shibpur, Howarh 711103, West Bengal, India;
| | - Jesús Salvador Velázquez-González
- Navigation and Positioning, Center Technologic de Telecomunicacions de Catalunya (CTTC), Avinguda Carl Friedrich Gauss, 11, 08860 Castelldefels, Spain; (J.S.V.-G.); (I.L.-G.)
| | - Ignacio Llamas-Garro
- Navigation and Positioning, Center Technologic de Telecomunicacions de Catalunya (CTTC), Avinguda Carl Friedrich Gauss, 11, 08860 Castelldefels, Spain; (J.S.V.-G.); (I.L.-G.)
| | - Bora Ung
- Electrical Engineering Department, Ecole de Technologie Superieure, Montreal, QC H3C 1K3, Canada;
| | - Joan Bas
- Space and Resilient Communications and Systems (SRCOM), Center Technologic de Telecomunicacions de Catalunya (CTTC), Avinguda Carl Friedrich Gauss, 11, 08860 Castelldefels, Spain;
| | - Rakesh Dubey
- Institute of Physics, University of Szczecin, 70-453 Szczecin, Poland;
| | - Satyendra K. Mishra
- Space and Resilient Communications and Systems (SRCOM), Center Technologic de Telecomunicacions de Catalunya (CTTC), Avinguda Carl Friedrich Gauss, 11, 08860 Castelldefels, Spain;
| |
Collapse
|
2
|
Wu T, Shi H, Zhou X, Liu Y, Wang L, Shi Y, Wang J, Lu Y, Gu X, He C. Full-range depth-encoded swept source polarization sensitive optical coherence tomography. OPTICS EXPRESS 2024; 32:9374-9383. [PMID: 38571173 DOI: 10.1364/oe.510970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 02/09/2024] [Indexed: 04/05/2024]
Abstract
To realize the high sensitivity polarization sensitive optical coherence tomography (PS-OCT) imaging, a fiber-based full-range depth-encoded swept source PS-OCT (SS-PS-OCT) method is proposed. The two OCT images corresponding to the orthogonal polarized input light are located on the high sensitivity imaging region of the opposite sides relative to the zero optical path difference position. The full-range OCT images can be obtained by implementing the spatial phase modulation in the reference arm. The detection sensitivity of the system was measured experimentally to be 67 dB when the imaging depth approaching to 2 mm. The imaging of the biological tissue verifies that the proposed full-range depth-encoded SS-PS-OCT system has the higher detection sensitivity compared with the conventional depth encoded SS-PS-OCT system. Finally, we demonstrated the full-range high sensitivity phase retardation image of the bovine tendon and skin of human fingertip. The fiber-based full-range depth-encoded SS-PS-OCT method can realize the high sensitivity birefringence imaging in the medical diagnosis scenes with the requirements for long imaging range and high detection sensitivity.
Collapse
|
3
|
Duan MQ, Byers RA, Danby SG, Sahib S, Cha A, Zang C, Werth J, Adiri R, Taylor RN, Cork MJ, Matcher SJ. Potential application of PS-OCT in the safety assessment of non-steroidal topical creams for atopic dermatitis treatment. BIOMEDICAL OPTICS EXPRESS 2023; 14:4126-4136. [PMID: 37799702 PMCID: PMC10549734 DOI: 10.1364/boe.494464] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 06/16/2023] [Accepted: 06/27/2023] [Indexed: 10/07/2023]
Abstract
Crisaborole 2% ointment is a non-steroidal treatment for mild-moderate atopic dermatitis (AD) and may produce fewer adverse effects than topical corticosteroids (TCS). We used PS-OCT to quantify dermal collagen at baseline and after 29 days of treatment with crisaborole and betamethasone valerate (BMV), in 32 subjects. PS-OCT detected a mean increase 1 × 10-6, 95% CI (6.3, 1.37) × 10-6 in dermal birefringence following TCS use (p < 0.0001, ad-hoc, not powered), whereas a change of -4 × 10-6, 95% CI (-32, 24) × 10-6 was detected for crisaborole (p = 0.77, ad-hoc, not powered). These results could suggest a differential effect on dermal collagen between the two compounds. PS-OCT may thus find an important role in safety assessment of novel AD treatment' and larger trials are warranted.
Collapse
Affiliation(s)
- M. Q. Duan
- Department of Electronic and Electrical Engineering, The
University of Sheffield, The Kroto Building, Broad Lane, Sheffield, S3 7HQ, UK
| | - Robert A. Byers
- Sheffield Dermatology Research, Department of Infection and Immunity and Cardiovascular Disease, The University of Sheffield Medical School, Beech Hill Road, Sheffield, S10 2RX, UK
| | - Simon G. Danby
- Sheffield Dermatology Research, Department of Infection and Immunity and Cardiovascular Disease, The University of Sheffield Medical School, Beech Hill Road, Sheffield, S10 2RX, UK
| | - Sura Sahib
- Sheffield Dermatology Research, Department of Infection and Immunity and Cardiovascular Disease, The University of Sheffield Medical School, Beech Hill Road, Sheffield, S10 2RX, UK
| | - Amy Cha
- Pfizer, Inc, New York, NY, USA
| | | | | | - Roni Adiri
- Pfizer Pharmaceutical Israel LTD, Israel
| | - Rosie N. Taylor
- The Statistical Service Unit, The University of Sheffield, Sheffield, UK
| | - Michael J. Cork
- Sheffield Dermatology Research, Department of Infection and Immunity and Cardiovascular Disease, The University of Sheffield Medical School, Beech Hill Road, Sheffield, S10 2RX, UK
| | - Stephen J. Matcher
- Department of Electronic and Electrical Engineering, The
University of Sheffield, The Kroto Building, Broad Lane, Sheffield, S3 7HQ, UK
| |
Collapse
|
4
|
Bouma B, de Boer J, Huang D, Jang I, Yonetsu T, Leggett C, Leitgeb R, Sampson D, Suter M, Vakoc B, Villiger M, Wojtkowski M. Optical coherence tomography. NATURE REVIEWS. METHODS PRIMERS 2022; 2:79. [PMID: 36751306 PMCID: PMC9901537 DOI: 10.1038/s43586-022-00162-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
Optical coherence tomography (OCT) is a non-contact method for imaging the topological and internal microstructure of samples in three dimensions. OCT can be configured as a conventional microscope, as an ophthalmic scanner, or using endoscopes and small diameter catheters for accessing internal biological organs. In this Primer, we describe the principles underpinning the different instrument configurations that are tailored to distinct imaging applications and explain the origin of signal, based on light scattering and propagation. Although OCT has been used for imaging inanimate objects, we focus our discussion on biological and medical imaging. We examine the signal processing methods and algorithms that make OCT exquisitely sensitive to reflections as weak as just a few photons and that reveal functional information in addition to structure. Image processing, display and interpretation, which are all critical for effective biomedical imaging, are discussed in the context of specific applications. Finally, we consider image artifacts and limitations that commonly arise and reflect on future advances and opportunities.
Collapse
Affiliation(s)
- B.E. Bouma
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, USA,Institute for Medical Engineering and Physics, Massachusetts Institute of Technology, Cambridge, MA, USA,Harvard Medical School, Boston, MA, USA,Corresponding author:
| | - J.F. de Boer
- Department of Physics and Astronomy, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - D. Huang
- Casey Eye Institute, Oregon Health and Science University, Portland, OR, USA
| | - I.K. Jang
- Harvard Medical School, Boston, MA, USA,Cardiology Division, Massachusetts General Hospital, Boston, MA, USA
| | - T. Yonetsu
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University
| | - C.L. Leggett
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, MN, USA
| | - R. Leitgeb
- Institute of Medical Physics, University of Vienna, Wien, Austria
| | - D.D. Sampson
- School of Physics and School of Biosciences and Medicine, University of Surrey, Guildford, United Kingdom
| | - M. Suter
- Harvard Medical School, Boston, MA, USA,Division of Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA
| | - B. Vakoc
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, USA,Harvard Medical School, Boston, MA, USA
| | - M. Villiger
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, USA,Harvard Medical School, Boston, MA, USA
| | - M. Wojtkowski
- Institute of Physical Chemistry and International Center for Translational Eye Research, Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland,Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Torun, Poland
| |
Collapse
|
5
|
Baumann B, Harper DJ, Eugui P, Gesperger J, Lichtenegger A, Merkle CW, Augustin M, Woehrer A. Improved accuracy of quantitative birefringence imaging by polarization sensitive OCT with simple noise correction and its application to neuroimaging. JOURNAL OF BIOPHOTONICS 2021; 14:e202000323. [PMID: 33332741 DOI: 10.1002/jbio.202000323] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Revised: 12/13/2020] [Accepted: 12/14/2020] [Indexed: 05/25/2023]
Abstract
Polarization-sensitive optical coherence tomography (PS-OCT) enables three-dimensional imaging of biological tissues based on the inherent contrast provided by scattering and polarization properties. In fibrous tissue such as the white matter of the brain, PS-OCT allows quantitative mapping of tissue birefringence. For the popular PS-OCT layout using a single circular input state, birefringence measurements are based on a straight-forward evaluation of phase retardation data. However, the accuracy of these measurements strongly depends on the signal-to-noise ratio (SNR) and is prone to mapping artifacts when the SNR is low. Here we present a simple yet effective approach for improving the accuracy of PS-OCT phase retardation and birefringence measurements. By performing a noise bias correction of the detected OCT signal amplitudes, the impact of the noise floor on retardation measurements can be markedly reduced. We present simulation data to illustrate the influence of the noise bias correction on phase retardation measurements and support our analysis with real-world PS-OCT image data.
Collapse
Affiliation(s)
- Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Danielle J Harper
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Pablo Eugui
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Johanna Gesperger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- Division of Neuropathology and Neurochemistry, Department of Neurology, Medical University of Vienna, Vienna, Austria
| | - Antonia Lichtenegger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Conrad W Merkle
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Marco Augustin
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Adelheid Woehrer
- Division of Neuropathology and Neurochemistry, Department of Neurology, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
6
|
Sharma S, Hartl G, Naveed SK, Blessing K, Sharma G, Singh K. Input polarization-independent polarization-sensitive optical coherence tomography using a depolarizer. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:043706. [PMID: 32357732 DOI: 10.1063/5.0001871] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Accepted: 03/25/2020] [Indexed: 06/11/2023]
Abstract
Polarization-sensitive optical coherence tomography is gaining attention because of its ability to diagnose certain pathological conditions at an early stage. The majority of polarization-sensitive optical coherence tomography systems require a polarization controller and a polarizer to obtain the optimal polarization state of the light at the sample. Such systems are prone to misalignment since any movement of the optical fiber normally coupled to the light source will change the polarization state of the incident beam. We propose and demonstrate an input polarization-independent polarization-sensitive optical coherence tomography system using a depolarizer that works for any input polarization state of the light source. The change in the optical power at the sample for arbitrary input polarized light for the standard polarization-sensitive optical coherence tomography system was found to be approximately 84% compared to 9% for our proposed method. The developed system was used to measure the retardance and optical axis orientation of a quarter-wave plate and the obtained values matched closely to the expectation. To further demonstrate the capability of measuring the birefringent properties of biological samples, we also imaged the nail bed. We believe that the proposed system is a robust polarization-sensitive optical coherence tomography system and that it will improve the diagnostic capabilities in clinical settings.
Collapse
Affiliation(s)
- Shivani Sharma
- Max Planck Institute for the Science of Light, Staudtsr. 2, 91058 Erlangen, Germany
| | - Georg Hartl
- Max Planck Institute for the Science of Light, Staudtsr. 2, 91058 Erlangen, Germany
| | - Sheeza K Naveed
- Max Planck Institute for the Science of Light, Staudtsr. 2, 91058 Erlangen, Germany
| | - Katharina Blessing
- Max Planck Institute for the Science of Light, Staudtsr. 2, 91058 Erlangen, Germany
| | - Gargi Sharma
- Max Planck Institute for the Science of Light, Staudtsr. 2, 91058 Erlangen, Germany
| | - Kanwarpal Singh
- Max Planck Institute for the Science of Light, Staudtsr. 2, 91058 Erlangen, Germany
| |
Collapse
|
7
|
Li W, Narice BF, Anumba DO, Matcher SJ. Polarization-sensitive optical coherence tomography with a conical beam scan for the investigation of birefringence and collagen alignment in the human cervix. BIOMEDICAL OPTICS EXPRESS 2019; 10:4190-4206. [PMID: 31453004 PMCID: PMC6701558 DOI: 10.1364/boe.10.004190] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 05/27/2019] [Accepted: 05/29/2019] [Indexed: 05/19/2023]
Abstract
By measuring the phase retardance of a cervical extracellular matrix, our in-house polarization-sensitive optical coherence tomography (PS-OCT) was shown to be capable of (1) mapping the distribution of collagen fibers in the non-gravid cervix, (2) accurately determining birefringence, and (3) measuring the distinctive depolarization of the cervical tissue. A conical beam scan strategy was also employed to explore the 3D orientation of the collagen fibers in the cervix by interrogating the samples with an incident light at 45° and successive azimuthal rotations of 0-360°. Our results confirmed previous observations by X-ray diffraction, suggesting that in the non-gravid human cervix collagen fibers adjacent to the endocervical canal and in the outermost areas tend to arrange in a longitudinal fashion whereas in the middle area they are oriented circumferentially. PS-OCT can assess the microstructure of the human cervical collagen in vitro and holds the potential to help us better understand cervical remodeling prior to birth pending the development of an in vivo probe.
Collapse
Affiliation(s)
- Wei Li
- Biophotonics Group, Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, S3 7HQ, UK
- Co-first authors with equal contribution
| | - Brenda F. Narice
- Reproductive and Developmental Medicine, Department of Oncology and Metabolism, University of Sheffield, Sheffield, S10 2SF, UK
- Co-first authors with equal contribution
| | - Dilly O. Anumba
- Reproductive and Developmental Medicine, Department of Oncology and Metabolism, University of Sheffield, Sheffield, S10 2SF, UK
| | - Stephen J. Matcher
- Biophotonics Group, Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield, S3 7HQ, UK
| |
Collapse
|
8
|
Yamanari M, Uematsu S, Ishihara K, Ikuno Y. Parallel detection of Jones-matrix elements in polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2019; 10:2318-2336. [PMID: 31149375 PMCID: PMC6524579 DOI: 10.1364/boe.10.002318] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/16/2019] [Accepted: 03/18/2019] [Indexed: 06/09/2023]
Abstract
The polarization properties of a sample can be characterized using a Jones matrix. To measure the Jones matrix without assumptions of the sample, two different incident states of polarization are usually used. This requirement often causes certain drawbacks in polarization-sensitive optical coherence tomography (PS-OCT), e.g., a decrease in the effective A-scan rate or axial depth range, if a multiplexing scheme is used. Because both the A-scan rate and axial depth range are important for clinical applications, including the imaging of an anterior eye segment, a new PS-OCT method that does not have these drawbacks is desired. Here, we present a parallel-detection approach that maintains the same A-scan rate and axial measurement range as conventional OCT. The interferometer consists of fiber-optic components, most of which are polarization-maintaining components with fast-axis blocking free from polarization management. When a parallel detection is implemented using swept-source OCT (SS-OCT), synchronization between the A-scans and synchronization between the detection channels have critical effects on the Jones-matrix measurement. Because it is difficult to achieve perfect synchronization using only hardware, we developed a solution using a numerical correction with signals from a static mirror. Using the developed system, we demonstrate the imaging of an anterior eye segment from the cornea to the back surface of the crystalline lens.
Collapse
Affiliation(s)
- Masahiro Yamanari
- Engineering Department, Tomey Corporation, 2-11-33 Noritakeshinmachi, Nishiku, Nagoya, Aichi, 451-0051, Japan
| | - Sato Uematsu
- Department of Ophthalmology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Kenji Ishihara
- Engineering Department, Tomey Corporation, 2-11-33 Noritakeshinmachi, Nishiku, Nagoya, Aichi, 451-0051, Japan
| | - Yasushi Ikuno
- Ikuno Eye Center, 2-9-10 3F Juso-Higashi, Yodogawaku, Osaka, Osaka, 532-0023, Japan
| |
Collapse
|
9
|
Wang J, Xu Y, Mesa KJ, South FA, Chaney EJ, Spillman DR, Barkalifa R, Marjanovic M, Carney PS, Higham AM, Liu ZG, Boppart SA. Complementary use of polarization-sensitive and standard OCT metrics for enhanced intraoperative differentiation of breast cancer. BIOMEDICAL OPTICS EXPRESS 2018; 9:6519-6528. [PMID: 31065446 PMCID: PMC6490989 DOI: 10.1364/boe.9.006519] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Revised: 11/11/2018] [Accepted: 11/12/2018] [Indexed: 05/19/2023]
Abstract
We report the development and implementation of an intraoperative polarization-sensitive optical coherence tomography (PS-OCT) system for enhancing breast cancer detection. A total of 3440 PS-OCT images were intraoperatively acquired from 9 human breast specimens diagnosed by H&E histology as healthy fibro-adipose tissue (n = 2), healthy stroma (n = 2), or invasive ductal carcinoma (IDC, n = 5). A standard OCT-based metric (coefficient of variation (CV)) and PS-OCT-based metrics sensitive to biological tissue from birefringence (i.e., retardation and degree of polarization uniformity (DOPU)) were derived from 398 statistically different and independent images selected by correlation coefficient analysis. We found the standard OCT-based metric and PS-OCT-based metrics were complementary for the differentiation of healthy fibro-adipose tissue, healthy stroma, and IDC. While the CV of fibro-adipose tissue was significantly higher (p<0.001) than those of either stroma or IDC, the CV difference between stroma and IDC was minimal. On the other hand, stroma was associated with significantly higher (p<0.001) retardation and significantly lower (p<0.001) DOPU as compared to IDC. By leveraging the complementary information acquired by the intraoperative PS-OCT system, healthy fibro-adipose tissue, healthy stroma, and IDC can be differentiated with an accuracy of 89.4%, demonstrating the potential of PS-OCT as an adjunct modality for enhanced intraoperative differentiation of human breast cancer.
Collapse
Affiliation(s)
- Jianfeng Wang
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Yang Xu
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Kelly J. Mesa
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Fredrick A. South
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Eric J. Chaney
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Darold R. Spillman
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Ronit Barkalifa
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Marina Marjanovic
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - P. Scott Carney
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | | | | | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Bioengineering, University of Illinois at Urbana–Champaign, Urbana, Illinois, USA
- Carle Illinois College of Medicine, University of Illinois at Urbana–Champaign Urbana, Illinois, USA
| |
Collapse
|
10
|
Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7050474] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
11
|
Amin MN, Faisal M. Highly nonlinear polarization-maintaining photonic crystal fiber with nanoscale GaP strips. APPLIED OPTICS 2016; 55:10030-10037. [PMID: 27958407 DOI: 10.1364/ao.55.010030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A highly birefringent silica photonic crystal fiber (PCF) is proposed with nanoscale gallium phosphide strips at the core and modified spiral cladding air hole distribution. Optical properties of the PCF are simulated using the finite element method. Significant influences of low-refractive-index slot region confinement and high-index strips confinement are observed for two different modes. This introduces a high birefringence of ∼0.58 at 1.55 μm wavelength. Moreover, a high nonlinearity coefficient of the order of ∼104 W-1 km-1 is achieved in the wavelength range from 1.4 to 1.7 μm. The proposed fiber will find promising applications in coherent optical communications and sensing applications.
Collapse
|
12
|
South FA, Liu YZ, Xu Y, Shemonski ND, Carney PS, Boppart SA. Polarization-sensitive interferometric synthetic aperture microscopy. APPLIED PHYSICS LETTERS 2015; 107:211106. [PMID: 26648593 PMCID: PMC4662671 DOI: 10.1063/1.4936236] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Accepted: 11/10/2015] [Indexed: 05/20/2023]
Abstract
Three-dimensional optical microscopy suffers from the well-known compromise between transverse resolution and depth-of-field. This is true for both structural imaging methods and their functional extensions. Interferometric synthetic aperture microscopy (ISAM) is a solution to the 3D coherent microscopy inverse problem that provides depth-independent transverse resolution. We demonstrate the extension of ISAM to polarization sensitive imaging, termed polarization-sensitive interferometric synthetic aperture microscopy (PS-ISAM). This technique is the first functionalization of the ISAM method and provides improved depth-of-field for polarization-sensitive imaging. The basic assumptions of polarization-sensitive imaging are explored, and refocusing of birefringent structures is experimentally demonstrated. PS-ISAM enables high-resolution volumetric imaging of birefringent materials and tissue.
Collapse
|
13
|
Claeson AA, Yeh YJ, Black AJ, Akkin T, Barocas VH. Marker-Free Tracking of Facet Capsule Motion Using Polarization-Sensitive Optical Coherence Tomography. Ann Biomed Eng 2015; 43:2953-66. [PMID: 26055969 DOI: 10.1007/s10439-015-1349-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Accepted: 05/27/2015] [Indexed: 12/28/2022]
Abstract
We proposed and tested a method by which surface strains of biological tissues can be captured without the use of fiducial markers by instead, utilizing the inherent structure of the tissue. We used polarization-sensitive optical coherence tomography (PS OCT) to obtain volumetric data through the thickness and across a partial surface of the lumbar facet capsular ligament during three cases of static bending. Reflectivity and phase retardance were calculated from two polarization channels, and a power spectrum analysis was performed on each a-line to extract the dominant banding frequency (a measure of degree of fiber alignment) through the maximum value of the power spectrum (maximum power). Maximum powers of all a-lines for each case were used to create 2D visualizations, which were subsequently tracked via digital image correlation. In-plane strains were calculated from measured 2D deformations and converted to 3D surface strains by including out-of-plane motion obtained from the PS OCT image. In-plane strains correlated with 3D strains (R(2) ≥ 0.95). Using PS OCT for marker-free motion tracking of biological tissues is a promising new technique because it relies on the structural characteristics of the tissue to monitor displacement instead of external fiducial markers.
Collapse
Affiliation(s)
- Amy A Claeson
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA.
| | - Yi-Jou Yeh
- Department of Electrical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Adam J Black
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Taner Akkin
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Victor H Barocas
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, 55455, USA.
| |
Collapse
|
14
|
Duan L, Marvdashti T, Ellerbee AK. Polarization-sensitive interleaved optical coherence tomography. OPTICS EXPRESS 2015; 23:13693-703. [PMID: 26074618 DOI: 10.1364/oe.23.013693] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We introduce a new strategy for single-mode fiber based polarization-sensitive (PS-) optical coherence tomography (OCT) using orthogonally polarized optical frequency combs (OFC) in the sample arm. The two OFCs are tuned to be interleaved in the spectral domain, permitting simultaneous measurement of both polarization states from the same spatial region C close to the location of zero pathlength delay. The two polarization states of the beam in the sample arm are demultiplexed by interpolation after performing wavelength stabilization via a two-mirror calibration method. The system uses Jones matrix methods to measure quantitatively the round-trip phase retardation B-scans in the sample. A glass plate and quarter-wave plate were measured to validate the accuracy of the birefringence measurement. Further, we demonstrated the potential of this system for biomedical applications by measurement of chicken breast muscle.
Collapse
|
15
|
Ding Z, Liang CP, Tang Q, Chen Y. Quantitative single-mode fiber based PS-OCT with single input polarization state using Mueller matrix. BIOMEDICAL OPTICS EXPRESS 2015; 6:1828-43. [PMID: 26137383 PMCID: PMC4467718 DOI: 10.1364/boe.6.001828] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Revised: 04/12/2015] [Accepted: 04/14/2015] [Indexed: 05/18/2023]
Abstract
We present a simple but effective method to quantitatively measure the birefringence of tissue by an all single-mode fiber (SMF) based polarization-sensitive optical coherence tomography (PS-OCT) with single input polarization state. We theoretically verify that our SMF based PS-OCT system can quantify the phase retardance and optic axis orientation after a simple calibration process using a quarter wave plate (QWP). Based on the proposed method, the quantification of the phase retardance and optic axis orientation of a Berek polarization compensator and biological tissues were demonstrated.
Collapse
Affiliation(s)
- Zhenyang Ding
- College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072,
China
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742
USA
- These authors contributed equally to this work
| | - Chia-Pin Liang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742
USA
- These authors contributed equally to this work
| | - Qinggong Tang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742
USA
| | - Yu Chen
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742
USA
| |
Collapse
|
16
|
Wang Z, Lee HC, Ahsen OO, Lee B, Choi W, Potsaid B, Liu J, Jayaraman V, Cable A, Kraus MF, Liang K, Hornegger J, Fujimoto JG. Depth-encoded all-fiber swept source polarization sensitive OCT. BIOMEDICAL OPTICS EXPRESS 2014; 5:2931-49. [PMID: 25401008 PMCID: PMC4230879 DOI: 10.1364/boe.5.002931] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/23/2014] [Accepted: 07/24/2014] [Indexed: 05/18/2023]
Abstract
Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of conventional OCT and can assess depth-resolved tissue birefringence in addition to intensity. Most existing PS-OCT systems are relatively complex and their clinical translation remains difficult. We present a simple and robust all-fiber PS-OCT system based on swept source technology and polarization depth-encoding. Polarization multiplexing was achieved using a polarization maintaining fiber. Polarization sensitive signals were detected using fiber based polarization beam splitters and polarization controllers were used to remove the polarization ambiguity. A simplified post-processing algorithm was proposed for speckle noise reduction relaxing the demand for phase stability. We demonstrated systems design for both ophthalmic and catheter-based PS-OCT. For ophthalmic imaging, we used an optical clock frequency doubling method to extend the imaging range of a commercially available short cavity light source to improve polarization depth-encoding. For catheter based imaging, we demonstrated 200 kHz PS-OCT imaging using a MEMS-tunable vertical cavity surface emitting laser (VCSEL) and a high speed micromotor imaging catheter. The system was demonstrated in human retina, finger and lip imaging, as well as ex vivo swine esophagus and cardiovascular imaging. The all-fiber PS-OCT is easier to implement and maintain compared to previous PS-OCT systems and can be more easily translated to clinical applications due to its robust design.
Collapse
Affiliation(s)
- Zhao Wang
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Hsiang-Chieh Lee
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Osman Oguz Ahsen
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - ByungKun Lee
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - WooJhon Choi
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Benjamin Potsaid
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
- Advanced Imaging Group, Thorlabs, Inc., Newton, NJ, USA
| | - Jonathan Liu
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | | | - Alex Cable
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
- Advanced Imaging Group, Thorlabs, Inc., Newton, NJ, USA
| | - Martin F. Kraus
- Pattern Recognition Lab and School of Advanced Optical Technologies, University Erlangen-Nürnberg, Erlangen, Germany
| | - Kaicheng Liang
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Joachim Hornegger
- Pattern Recognition Lab and School of Advanced Optical Technologies, University Erlangen-Nürnberg, Erlangen, Germany
| | - James G. Fujimoto
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| |
Collapse
|
17
|
Lu Z, Kasaragod D, Matcher SJ. Conical scan polarization-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2014; 5:752-62. [PMID: 24688811 PMCID: PMC3959841 DOI: 10.1364/boe.5.000752] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2013] [Revised: 11/29/2013] [Accepted: 12/20/2013] [Indexed: 05/18/2023]
Abstract
We report on a new articular cartilage imaging technique with potential for clinical arthroscopic use, by supplementing the variable-incidence-angle polarization-sensitive optical coherence tomography method previously developed by us with a conical beam scan protocol. The technique is validated on bovine tendon by comparing experimental data with simulated data generated using the extended Jones matrix calculus. A unique capability of this new optical technique is that it can locate the "brushing direction" of collagen fibers in articular cartilage, which is structural information that extends beyond established methods such as split-line photography or birefringent fast-axis measurement in that it is uniquely defined over the full azimuthal-angle range of (-π, + π). The mapping of this direction over the cartilage surface may offer insights into the optimal design of tissue-engineering scaffolds for cartilage repair.
Collapse
Affiliation(s)
- Zenghai Lu
- Department of Materials Science and Engineering, the Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ, UK
- Department of Electronic and Electrical Engineering, University of Sheffield, Mappin Street, Sheffield, S1 3JD, UK
| | - Deepa Kasaragod
- Department of Materials Science and Engineering, the Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ, UK
- Currently with the Computational Optics Group, University of Tsukuba, Tsukuba, Japan
| | - Stephen J Matcher
- Department of Materials Science and Engineering, the Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ, UK
| |
Collapse
|
18
|
Lin H, Kao MC, Lai CM, Huang JC, Kuo WC. All fiber optics circular-state swept source polarization-sensitive optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:21110. [PMID: 24084890 DOI: 10.1117/1.jbo.19.2.021110] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2013] [Accepted: 09/10/2013] [Indexed: 05/28/2023]
Abstract
A swept source (SS)-based circular-state (CS) polarization-sensitive optical coherence tomography (PS-OCT) constructed entirely with polarization-maintaining fiber optics components is proposed with the experimental verification. By means of the proposed calibration scheme, bulk quarter-wave plates can be replaced by fiber optics polarization controllers to, therefore, realize an all-fiber optics CS SSPS-OCT. We also present a numerical dispersion compensation method, which can not only enhance the axial resolution, but also improve the signal-to-noise ratio of the images. We demonstrate that this compact and portable CS SSPS-OCT system with an accuracy comparable to bulk optics systems requires less stringent lens alignment and can possibly serve as a technology to realize PS-OCT instrument for clinical applications (e.g., endoscopy). The largest deviations in the phase retardation (PR) and fast-axis (FA) angle due to sample probe in the linear scanning and a rotation angle smaller than 65 deg were of the same order as those in stationary probe setups. The influence of fiber bending on the measured PR and FA is also investigated. The largest deviations of the PR were 3.5 deg and the measured FA change by ~12 to 21 deg. Finally, in vivo imaging of the human fingertip and nail was successfully demonstrated with a linear scanning probe.
Collapse
Affiliation(s)
- Hermann Lin
- National Kaohsiung Normal University, Department of Optoelectronics & Communication Engineering, Kaohsiung 802, Taiwan
| | | | | | | | | |
Collapse
|
19
|
Yin B, Wang B, Rylander HG, Milner TE. Degradation in the degree of polarization in human retinal nerve fiber layer. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:16001. [PMID: 24390374 PMCID: PMC3881105 DOI: 10.1117/1.jbo.19.1.016001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2013] [Revised: 12/02/2013] [Accepted: 12/04/2013] [Indexed: 05/21/2023]
Abstract
Using a fiber-based swept-source (SS) polarization-sensitive optical coherence tomography (PS-OCT) system, we investigate the degree of polarization (DOP) of light backscattered from the retinal nerve fiber layer (RNFL) in normal human subjects. Algorithms for processing data were developed to analyze the deviation in phase retardation and intensity of backscattered light in directions parallel and perpendicular to the nerve fiber axis (fast and slow axes of RNFL). Considering superior, inferior, and nasal quadrants, we observe the strongest degradation in the DOP with increasing RNFL depth in the temporal quadrant. Retinal ganglion cell axons in normal human subjects are known to have the smallest diameter in the temporal quadrant, and the greater degradation observed in the DOP suggests that higher polarimetric noise may be associated with neural structure in the temporal RNFL. The association between depth degradation in the DOP and RNFL structural properties may broaden the utility of PS-OCT as a functional imaging technique.
Collapse
Affiliation(s)
- Biwei Yin
- University of Texas at Austin, Departments of Electrical and Computer Engineering, 1 University Station C0803, Austin, Texas 78712
- Address all correspondence to: Biwei Yin, E-mail:
| | - Bingqing Wang
- University of Texas at Austin, Department of Biomedical Engineering, 1 University Station, C0800, Austin, Texas 78712
| | - Henry G. Rylander
- University of Texas at Austin, Department of Biomedical Engineering, 1 University Station, C0800, Austin, Texas 78712
| | - Thomas E. Milner
- University of Texas at Austin, Department of Biomedical Engineering, 1 University Station, C0800, Austin, Texas 78712
| |
Collapse
|
20
|
Villiger M, Zhang EZ, Nadkarni SK, Oh WY, Vakoc BJ, Bouma BE. Spectral binning for mitigation of polarization mode dispersion artifacts in catheter-based optical frequency domain imaging. OPTICS EXPRESS 2013; 21:16353-69. [PMID: 23938487 PMCID: PMC3724396 DOI: 10.1364/oe.21.016353] [Citation(s) in RCA: 89] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Revised: 04/19/2013] [Accepted: 04/21/2013] [Indexed: 05/18/2023]
Abstract
Polarization mode dispersion (PMD) has been recognized as a significant barrier to sensitive and reproducible birefringence measurements with fiber-based, polarization-sensitive optical coherence tomography systems. Here, we present a signal processing strategy that reconstructs the local retardation robustly in the presence of system PMD. The algorithm uses a spectral binning approach to limit the detrimental impact of system PMD and benefits from the final averaging of the PMD-corrected retardation vectors of the spectral bins. The algorithm was validated with numerical simulations and experimental measurements of a rubber phantom. When applied to the imaging of human cadaveric coronary arteries, the algorithm was found to yield a substantial improvement in the reconstructed birefringence maps.
Collapse
Affiliation(s)
- Martin Villiger
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 40 Blossom Street, Boston, Massachusetts 02114, USA.
| | | | | | | | | | | |
Collapse
|
21
|
Bonesi M, Sattmann H, Torzicky T, Zotter S, Baumann B, Pircher M, Götzinger E, Eigenwillig C, Wieser W, Huber R, Hitzenberger CK. High-speed polarization sensitive optical coherence tomography scan engine based on Fourier domain mode locked laser. BIOMEDICAL OPTICS EXPRESS 2012; 3:2987-3000. [PMID: 23162734 PMCID: PMC3493228 DOI: 10.1364/boe.3.002987] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2012] [Revised: 10/23/2012] [Accepted: 10/23/2012] [Indexed: 05/04/2023]
Abstract
We report on a new swept source polarization sensitive optical coherence tomography scan engine that is based on polarization maintaining (PM) fiber technology. The light source is a Fourier domain mode locked laser with a PM cavity that operates in the 1300 nm wavelength regime. It is equipped with a PM buffer stage that doubles the fundamental sweep frequency of 54.5 kHz. The fiberization allows coupling of the scan engine to different delivery probes. In a first demonstration, we use the system for imaging human skin at an A-scan rate of 109 kHz. The system illuminates the sample with circularly polarized light and measures reflectivity, retardation, optic axis orientation, and Stokes vectors simultaneously. Furthermore, depolarization can be quantified by calculating the degree of polarization uniformity (DOPU). The high scanning speed of the system enables dense sampling in both, the x- and y-direction, which provides the opportunity to use 3D evaluation windows for DOPU calculation. This improves the spatial resolution of DOPU images considerably.
Collapse
Affiliation(s)
- Marco Bonesi
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| | - Harald Sattmann
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| | - Teresa Torzicky
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| | - Stefan Zotter
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| | - Michael Pircher
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| | - Erich Götzinger
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| | - Christoph Eigenwillig
- Lehrstuhl für BioMolekulare Optik, Fakultät für
Physik, Ludwig-Maximilians-Universität München, D-80538 München,
Germany
| | - Wolfgang Wieser
- Lehrstuhl für BioMolekulare Optik, Fakultät für
Physik, Ludwig-Maximilians-Universität München, D-80538 München,
Germany
| | - Robert Huber
- Lehrstuhl für BioMolekulare Optik, Fakultät für
Physik, Ludwig-Maximilians-Universität München, D-80538 München,
Germany
| | - Christoph K. Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical
University of Vienna, A-1090 Vienna, Austria
| |
Collapse
|
22
|
Robinson EC, Trägårdh J, Lindsay ID, Gersen H. Balanced detection for interferometry with a noisy source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:063705. [PMID: 22755632 DOI: 10.1063/1.4729474] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Optical properties of nanostructures depend on size, shape, material, and local environment. These characteristics can be probed interferometrically, given a broadband source. However, broadband supercontinuum sources are intrinsically noisy, limiting the measurement sensitivity. In this article we describe the application of an auto-balancing technique to reduce the noise in a broadband supercontinuum source, thus increasing the signal to noise ratio. We show a noise reduction of 41 dB allowing optical powers as small as 0.01 pW to be interferometrically detected with a 5 ms integration time.
Collapse
Affiliation(s)
- E C Robinson
- H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL, United Kingdom
| | | | | | | |
Collapse
|
23
|
Smith RM, Black AJ, Velamakanni SS, Akkin T, Tolkacheva EG. Visualizing the complex 3D geometry of the perfusion border zone in isolated rabbit heart. APPLIED OPTICS 2012; 51:2713-2721. [PMID: 22614494 DOI: 10.1364/ao.51.002713] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2011] [Accepted: 03/14/2012] [Indexed: 06/01/2023]
Abstract
Myocardial infarction, caused by a major blockage of a coronary artery, creates a border zone (BZ) between perfused and nonperfused tissue, which is believed to be the origin of fatal cardiac arrhythmias. We used a combination of optical clearing and polarization-sensitive optical coherence tomography to visualize a three-dimensional organization of the BZ in isolated rabbit hearts (n=5) at the microscopic level with a high spatial resolution. We found that the BZ has a complex three-dimensional structure with nonperfused areas penetrating into perfused tissue with finger-like projections. These "fingers" may play an important role in the initiation and maintenance of ventricular arrhythmias.
Collapse
Affiliation(s)
- Rebecca M Smith
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, USA
| | | | | | | | | |
Collapse
|
24
|
Baumann B, Choi W, Potsaid B, Huang D, Duker JS, Fujimoto JG. Swept source/Fourier domain polarization sensitive optical coherence tomography with a passive polarization delay unit. OPTICS EXPRESS 2012; 20:10229-41. [PMID: 22535114 PMCID: PMC3366588 DOI: 10.1364/oe.20.010229] [Citation(s) in RCA: 85] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Polarization sensitive optical coherence tomography (PS-OCT) is a functional imaging method that provides additional contrast using the light polarizing properties of a sample. This manuscript describes PS-OCT based on ultrahigh speed swept source / Fourier domain OCT operating at 1050 nm at 100 kHz axial scan rates using single mode fiber optics and a multiplexing approach. Unlike previously reported PS-OCT multiplexing schemes, the method uses a passive polarization delay unit and does not require active polarization modulating devices. This advance decreases system cost and avoids complex synchronization requirements. The polarization delay unit was implemented in the sample beam path in order to simultaneously illuminate the sample with two different polarization states. The orthogonal polarization components for the depth-multiplexed signals from the two input states were detected using dual balanced detection. PS-OCT images were computed using Jones calculus. 3D PS-OCT imaging was performed in the human and rat retina. In addition to standard OCT images, PS-OCT images were generated using contrast form birefringence and depolarization. Enhanced tissue discrimination as well as quantitative measurements of sample properties was demonstrated using the additional contrast and information contained in the PS-OCT images.
Collapse
Affiliation(s)
- Bernhard Baumann
- Department of Electrical Engineering and Computer Science, and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139,
USA
- New England Eye Center and Tufts Medical Center, Tufts University, Boston, Massachusetts 02116,
USA
| | - WooJhon Choi
- Department of Electrical Engineering and Computer Science, and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139,
USA
| | - Benjamin Potsaid
- Department of Electrical Engineering and Computer Science, and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139,
USA
- Advanced Imaging Group, Thorlabs, Inc., Newton, New Jersey 07860,
USA
| | - David Huang
- Casey Eye Institute, Oregon Health & Science University, Portland, Oregon 97239,
USA
| | - Jay S. Duker
- New England Eye Center and Tufts Medical Center, Tufts University, Boston, Massachusetts 02116,
USA
| | - James G. Fujimoto
- Department of Electrical Engineering and Computer Science, and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139,
USA
| |
Collapse
|
25
|
Amini R, Whitcomb JE, Al-Qaisi MK, Akkin T, Jouzdani S, Dorairaj S, Prata T, Illitchev E, Liebmann JM, Ritch R, Barocas VH. The posterior location of the dilator muscle induces anterior iris bowing during dilation, even in the absence of pupillary block. Invest Ophthalmol Vis Sci 2012; 53:1188-94. [PMID: 22281822 DOI: 10.1167/iovs.11-8408] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To examine the effect of the posterior location of the dilator on iris anterior curvature during dilation. METHODS An in vivo human study, an ex vivo porcine experiment, and an in silico computational model were performed in parallel. Iris anterior curvature was measured in vivo before and after dilation by time-domain slit lamp optical coherence tomography (SL-OCT). All patients (n = 7) had undergone laser peripheral iridotomy to eliminate any pupillary block due to primary angle-closure glaucoma. In the ex vivo experiments, isolated porcine irides (n = 30) were secured at the periphery and immersed in an oxygenated Krebs-Ringer buffer. Dilation was induced pharmaceutically by the addition of 2.5% phenylephrine and 1% tropicamide. An in-house optical coherence tomography (OCT) system was used to obtain iris images before and after dilation. A finite element model was also developed based on typical geometry of the iris from the initial OCT image. The iris was modeled as a neo-Hookean solid, and the active muscle component was applied only to the region specified as the dilator. RESULTS An increase in curvature and a decrease in chord length after dilation were observed in both experiments. In both the in vivo and ex vivo experiments, the curvature-to-chord length ratio increased significantly during dilation. Computer simulations agreed well with the experimental results only when the proper anatomic position of dilator was used. CONCLUSIONS The posterior location of the dilator contributes to the anterior iris bowing via a nonpupillary block dependent mechanism.
Collapse
Affiliation(s)
- Rouzbeh Amini
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Zhang J, Jing J, Wang P, Chen Z. Polarization-maintaining buffered Fourier domain mode-locked swept source for optical coherence tomography. OPTICS LETTERS 2011; 36:4788-90. [PMID: 22179884 PMCID: PMC3337216 DOI: 10.1364/ol.36.004788] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
A polarization-maintaining buffered Fourier domain mode-locked (FDML) swept source with a center wavelength of 1300 nm is demonstrated. The scanning rate of the buffered FDML swept source is doubled without sacrificing the output power of the swept source by combining two orthogonally polarized outputs with a polarization beam combiner. The stability of the swept source is improved because the polarization state of the laser beam inside the laser cavity is maintained without the use of any polarization controllers. The swept source is capable of an edge-to-edge tuning range of more than 150 nm and a FWHM range of 95 nm at a 102 kHz sweeping rate and with an average power of 12 mW. A swept source optical coherence tomography (SSOCT) system is developed utilizing this buffered FDML swept source. The axial resolution of the SSOCT system is measured to be 9.4 µm in air. The sensitivity of the SSOCT system is 107.5 dB at a depth of 0.25 mm with a 6 dB roll-off at a depth of 2.25 mm.
Collapse
Affiliation(s)
- Jun Zhang
- Beckman Laser Institute and the Department of Biomedical Engineering, University of California, Irvine, California 92612, USA.
| | | | | | | |
Collapse
|
27
|
Wang H, Black AJ, Zhu J, Stigen TW, Al-Qaisi MK, Netoff TI, Abosch A, Akkin T. Reconstructing micrometer-scale fiber pathways in the brain: multi-contrast optical coherence tomography based tractography. Neuroimage 2011; 58:984-92. [PMID: 21771662 DOI: 10.1016/j.neuroimage.2011.07.005] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2011] [Revised: 06/15/2011] [Accepted: 07/04/2011] [Indexed: 11/30/2022] Open
Abstract
Comprehensive understanding of connective neural pathways in the brain has put great challenges on the current imaging techniques, for which three-dimensional (3D) visualization of fiber tracts with high spatiotemporal resolution is desirable. Here we present optical imaging and tractography of rat brain ex-vivo using multi-contrast optical coherence tomography (MC-OCT), which is capable of simultaneously generating depth-resolved images of reflectivity, phase retardance, optic axis orientation and, for in-vivo studies, blood flow images. Using the birefringence property of myelin sheath, nerve fiber tracts as small as a few tens of micrometers can be resolved and neighboring fiber tracts with different orientations can be distinguished in cross-sectional optical slices, 2D en-face images and 3D volumetric images. Combinational contrast of MC-OCT images enables visualization of the spatial architecture and nerve fiber orientations in the brain with unprecedented detail. The results suggest that optical tractography, by virtue of its direct accessibility to nerve fibers, has the potential to validate diffusion magnetic resonance images and investigate structural connections in normal brain and neurological disorders. In addition, an endoscopic MC-OCT may be useful in neurosurgical interventions to aid in placement of deep brain stimulating electrodes.
Collapse
Affiliation(s)
- Hui Wang
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Elmaanaoui B, Wang B, Dwelle JC, McElroy AB, Liu SS, Rylander HG, Milner TE. Birefringence measurement of the retinal nerve fiber layer by swept source polarization sensitive optical coherence tomography. OPTICS EXPRESS 2011; 19:10252-68. [PMID: 21643283 PMCID: PMC3129618 DOI: 10.1364/oe.19.010252] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2011] [Revised: 04/19/2011] [Accepted: 04/28/2011] [Indexed: 05/18/2023]
Abstract
A Swept Source Polarization-Sensitive Optical Coherence Tomography (SS-PS-OCT) instrument has been designed, constructed, and verified to provide high sensitivity depth-resolved birefringence and phase retardation measurements of the retinal nerve fiber layer. The swept-source laser had a center wavelength of 1059 nm, a full-width-half-max spectral bandwidth of 58 nm and an A-line scan rate of 34 KHz. Power incident on the cornea was 440 µW and measured axial resolution was 17 µm in air. A multiple polarization state nonlinear fitting algorithm was used to measure retinal birefringence with low uncertainty. Maps of RNFL phase retardation in a subject measured with SS-PS-OCT compare well with those generated using a commercial scanning laser polarimetry instrument. Peak-to-valley variation of RNFL birefringence given here is less than values previously reported at 840nm.
Collapse
Affiliation(s)
- Badr Elmaanaoui
- Department of Electrical and Computer Engineering, University of Texas at Austin, 1 University Station C0803, Austin, TX 78712, USA.
| | | | | | | | | | | | | |
Collapse
|
29
|
Optical coherence tomography in biomedical research. Anal Bioanal Chem 2011; 400:2721-43. [DOI: 10.1007/s00216-011-5052-x] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2011] [Revised: 04/19/2011] [Accepted: 04/21/2011] [Indexed: 12/16/2022]
|
30
|
Lu Z, Kasaragod DK, Matcher SJ. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography. Phys Med Biol 2011; 56:1105-22. [PMID: 21263175 DOI: 10.1088/0031-9155/56/4/014] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincaré sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.
Collapse
Affiliation(s)
- Zenghai Lu
- Department of Materials Science and Engineering, The Kroto Research Institute, University of Sheffield, Sheffield, UK.
| | | | | |
Collapse
|
31
|
Kim KH, Park BH, Tu Y, Hasan T, Lee B, Li J, de Boer JF. Polarization-sensitive optical frequency domain imaging based on unpolarized light. OPTICS EXPRESS 2011; 19:552-61. [PMID: 21263595 DOI: 10.1364/oe.19.000552] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Polarization-sensitive optical coherence tomography (PS-OCT) is an augmented form of OCT, providing 3D images of both tissue structure and polarization properties. We developed a new method of polarization-sensitive optical frequency domain imaging (PS-OFDI), which is based on a wavelength-swept source. In this method the sample was illuminated with unpolarized light, which was composed of two orthogonal polarization states (i.e., separated by 180° in the Poincaré sphere) that are uncorrelated to each other. Reflection of these polarization states from within the sample was detected simultaneously and independently using a frequency multiplexing scheme. This simultaneous sample probing with two polarization states enabled determination of the depth-resolved Jones matrices of the sample. Polarization properties of the sample were obtained by analyzing the sample Jones matrices through eigenvector decomposition. The new PS-OFDI system ran at 31K wavelength-scans/s with 3072 pixels per wavelength-scan, and was tested by imaging a polarizer and several birefringent tissues such as chicken muscle and human skin. Lastly the new PS-OFDI was applied to imaging two cancer animal models: a mouse model by injecting cancer cells and a hamster cheek pouch model. These animal model studies demonstrated the significant differences in tissue polarization properties between cancer and normal tissues in vivo.
Collapse
Affiliation(s)
- Ki Hean Kim
- Department of Mechanical Engineering and Division of Integrative Biosciences and Biotechnology, Pohang University of Science and Technology, Pohang, Korea
| | | | | | | | | | | | | |
Collapse
|
32
|
Chuanmao Fan, Gang Yao. Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography. IEEE Trans Biomed Eng 2010; 57:2556-9. [DOI: 10.1109/tbme.2010.2053927] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|