1
|
Liu J, Fan Z, Ye X, Zhang Y, Liu M, Deng X. Modelling of the in-stent thrombus formation by dissipative particle dynamics. J Theor Biol 2024; 582:111758. [PMID: 38336241 DOI: 10.1016/j.jtbi.2024.111758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 12/05/2023] [Accepted: 01/30/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND Stent implantation is a highly efficacious intervention for the treatment of coronary atherosclerosis. Nevertheless, stent thrombosis and other post-operative complications persist, and the underlying mechanism of adverse event remains elusive. METHODS In the present study, a dissipative particle dynamics model was formulated to simulate the motion, adhesion, activation, and aggregation of platelets, with the aim of elucidating the mechanisms of in-stent thrombosis. FINDINGS The findings suggest that stent thrombosis arises from a complex interplay of multiple factors, including endothelial injury resulting from stent implantation and alterations in the hemodynamic milieu. Furthermore, the results suggest a noteworthy association between in-stent thrombosis and both the length of the endothelial injured site and the degree of stent malposition. Specifically, the incidence of stent thrombosis appears to rise in tandem with the extent of the injured site, while moderate stent malposition is more likely to result in in-stent thrombosis compared to severe or minor malposition. INTERPRETATION This study offers novel research avenues for investigating the plasticity mechanism of stent thrombosis, while also facilitating the clinical prediction of stent thrombosis formation and the development of more precise treatment strategies.
Collapse
Affiliation(s)
- Jiashuai Liu
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou Jiangsu 213001, China
| | - Zhenmin Fan
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou Jiangsu 213001, China.
| | - Xia Ye
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou Jiangsu 213001, China
| | - Yingying Zhang
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Center for Rehabilitation Technical Aids, Beijing 100176, China.
| | - Mingyuan Liu
- Department of Vascular Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing Center of Vascular Surgery, Beijing 100050, China
| | - Xiaoyan Deng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| |
Collapse
|
2
|
Teeraratkul C, Tomaiuolo M, Stalker TJ, Mukherjee D. Investigating clot-flow interactions by integrating intravital imaging with in silico modeling for analysis of flow, transport, and hemodynamic forces. Sci Rep 2024; 14:696. [PMID: 38184693 PMCID: PMC10771506 DOI: 10.1038/s41598-023-49945-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 12/13/2023] [Indexed: 01/08/2024] Open
Abstract
As a blood clot forms, grows, deforms, and embolizes following a vascular injury, local clot-flow interactions lead to a highly dynamic flow environment. The local flow influences transport of biochemical species relevant for clotting, and determines the forces on the clot that in turn lead to clot deformation and embolization. Despite this central role, quantitative characterization of this dynamic clot-flow interaction and flow environment in the clot neighborhood remains a major challenge. Here, we propose an approach that integrates dynamic intravital imaging with computer geometric modeling and computational flow and transport modeling to develop a unified in silico framework to quantify the dynamic clot-flow interactions. We outline the development of the methodology referred to as Intravital Integrated In Silico Modeling or IVISim, and then demonstrate the method on a sample set of simulations comprising clot formation following laser injury in two mouse cremaster arteriole injury model data: one wild-type mouse case, and one diYF knockout mouse case. Simulation predictions are verified against experimental observations of transport of caged fluorescent Albumin (cAlb) in both models. Through these simulations, we illustrate how the IVISim methodology can provide insights into hemostatic processes, the role of flow and clot-flow interactions, and enable further investigations comparing and contrasting different biological model scenarios and parameter variations.
Collapse
Affiliation(s)
- Chayut Teeraratkul
- Paul M Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA
| | - Maurizio Tomaiuolo
- Cardeza Foundation for Hematologic Research, Department of Medicine, Thomas Jefferson University, Philadelphia, USA
| | | | - Debanjan Mukherjee
- Paul M Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, USA.
| |
Collapse
|
3
|
Tsyu NG, Belyaev AV. Coarse-grained simulations of von Willebrand factor adsorption to collagen with consequent platelet recruitment. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3747. [PMID: 37366014 DOI: 10.1002/cnm.3747] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 05/18/2023] [Accepted: 06/11/2023] [Indexed: 06/28/2023]
Abstract
A multimeric glycoprotein of blood plasma-Von Willebrand factor (VWF)-mediates platelet adhesion to the fibrillar collagen of the subendothelial matrix if the blood vessel walls are damaged. The adsorption of VWF to collagen is thus essential for the initial stages of platelet hemostasis and thrombosis, as it plays a role of a molecular bridge between the injury and platelet adhesion receptors. Biomechanical complexity and sensitivity to the hydrodynamics are inherent in this system, therefore, modern computational methods supplement experimental studies of biophysical and molecular mechanisms that underlie platelet adhesion and aggregation in the blood flow. In the present paper, we propose a simulation framework for the VWF-mediated platelet adhesion to a plane wall with immobilized binding sites for VWF under the action of shear flow. VWF multimers and platelets are represented in the model by particles connected by elastic bonds and immersed in a viscous continuum fluid. This work complements the scientific field by taking into account the shape of a flattened platelet, but keeping a compromise between the detail of the description and the computational complexity of the model.
Collapse
Affiliation(s)
- Noel G Tsyu
- Faculty of Physics, M.V. Lomonosov Moscow State University, Moscow, Russia
| | - Aleksey V Belyaev
- Faculty of Physics, M.V. Lomonosov Moscow State University, Moscow, Russia
| |
Collapse
|
4
|
Guerrero-Hurtado M, Garcia-Villalba M, Gonzalo A, Martinez-Legazpi P, Kahn AM, McVeigh E, Bermejo J, del Alamo JC, Flores O. Efficient multi-fidelity computation of blood coagulation under flow. PLoS Comput Biol 2023; 19:e1011583. [PMID: 37889899 PMCID: PMC10659216 DOI: 10.1371/journal.pcbi.1011583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 11/20/2023] [Accepted: 10/09/2023] [Indexed: 10/29/2023] Open
Abstract
Clot formation is a crucial process that prevents bleeding, but can lead to severe disorders when imbalanced. This process is regulated by the coagulation cascade, a biochemical network that controls the enzyme thrombin, which converts soluble fibrinogen into the fibrin fibers that constitute clots. Coagulation cascade models are typically complex and involve dozens of partial differential equations (PDEs) representing various chemical species' transport, reaction kinetics, and diffusion. Solving these PDE systems computationally is challenging, due to their large size and multi-scale nature. We propose a multi-fidelity strategy to increase the efficiency of coagulation cascade simulations. Leveraging the slower dynamics of molecular diffusion, we transform the governing PDEs into ordinary differential equations (ODEs) representing the evolution of species concentrations versus blood residence time. We then Taylor-expand the ODE solution around the zero-diffusivity limit to obtain spatiotemporal maps of species concentrations in terms of the statistical moments of residence time, [Formula: see text], and provide the governing PDEs for [Formula: see text]. This strategy replaces a high-fidelity system of N PDEs representing the coagulation cascade of N chemical species by N ODEs and p PDEs governing the residence time statistical moments. The multi-fidelity order (p) allows balancing accuracy and computational cost providing a speedup of over N/p compared to high-fidelity models. Moreover, this cost becomes independent of the number of chemical species in the large computational meshes typical of the arterial and cardiac chamber simulations. Using a coagulation network with N = 9 and an idealized aneurysm geometry with a pulsatile flow as a benchmark, we demonstrate favorable accuracy for low-order models of p = 1 and p = 2. The thrombin concentration in these models departs from the high-fidelity solution by under 20% (p = 1) and 2% (p = 2) after 20 cardiac cycles. These multi-fidelity models could enable new coagulation analyses in complex flow scenarios and extensive reaction networks. Furthermore, it could be generalized to advance our understanding of other reacting systems affected by flow.
Collapse
Affiliation(s)
| | | | - Alejandro Gonzalo
- Department of Mechanical Engineering, University of Washington, Seattle, Washington, United States of America
| | - Pablo Martinez-Legazpi
- Department of Mathematical Physics and Fluids, Facultad de Ciencias, Universidad Nacional de Educación a Distancia, UNED, Spain
- CIBERCV, Madrid, Spain
| | - Andrew M. Kahn
- Division of Cardiovascular Medicine, University of California San Diego, La Jolla, California, United States of America
| | - Elliot McVeigh
- Division of Cardiovascular Medicine, University of California San Diego, La Jolla, California, United States of America
- Department of Bioengineering, University of California San Diego, La Jolla, California, United States of America
- Department of Radiology, University of California San Diego, La Jolla, California, United States of America
| | - Javier Bermejo
- CIBERCV, Madrid, Spain
- Hospital General Universitario Gregorio Marañón, Madrid, Spain
- Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain
- Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain
| | - Juan C. del Alamo
- Department of Mechanical Engineering, University of Washington, Seattle, Washington, United States of America
- Center for Cardiovascular Biology, University of Washington, Seattle, Washington, United States of America
- Division of Cardiology, University of Washington, Seattle, Washington, United States of America
| | - Oscar Flores
- Department of Aerospace Engineering, Universidad Carlos III de Madrid, Leganés, Spain
| |
Collapse
|
5
|
Spartera M, Stracquadanio A, Pessoa-Amorim G, Harston G, Mazzucco S, Young V, Von Ende A, Hess AT, Ferreira VM, Kennedy J, Neubauer S, Casadei B, Wijesurendra RS. Reduced Left Atrial Rotational Flow Is Independently Associated With Embolic Brain Infarcts. JACC Cardiovasc Imaging 2023; 16:1149-1159. [PMID: 37204381 DOI: 10.1016/j.jcmg.2023.03.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 02/22/2023] [Accepted: 03/10/2023] [Indexed: 05/20/2023]
Abstract
BACKGROUND Up to 25% of embolic strokes occur in individuals without atrial fibrillation (AF) or other identifiable mechanisms. OBJECTIVES This study aims to assess whether left atrial (LA) blood flow characteristics are associated with embolic brain infarcts, independently of AF. METHODS The authors recruited 134 patients: 44 with a history of ischemic stroke and 90 with no history of stroke but CHA2DS2VASc score ≥1. Cardiac magnetic resonance (CMR) evaluated cardiac function and LA 4-dimensional flow parameters, including velocity and vorticity (a measure of rotational flow), and brain magnetic resonance imaging (MRI) was performed to detect large noncortical or cortical infarcts (LNCCIs) (likely embolic), or nonembolic lacunar infarcts. RESULTS Patients (41% female; age 70 ± 9 years) had moderate stroke risk (median CHA2DS2VASc = 3, Q1-Q3: 2-4). Sixty-eight (51%) had diagnosed AF, of whom 58 (43%) were in AF during CMR. Thirty-nine (29%) had ≥1 LNCCI, 20 (15%) had ≥1 lacunar infarct without LNCCI, and 75 (56%) had no infarct. Lower LA vorticity was significantly associated with prevalent LNCCIs after adjustment for AF during CMR, history of AF, CHA2DS2VASc score, LA emptying fraction, LA indexed maximum volume, left ventricular ejection fraction, and indexed left ventricular mass (OR: 2.06 [95% CI: 1.08-3.92 per SD]; P = 0.027). By contrast, LA flow peak velocity was not significantly associated with LNCCIs (P = 0.21). No LA parameter was associated with lacunar infarcts (all P > 0.05). CONCLUSIONS Reduced LA flow vorticity is significantly and independently associated with embolic brain infarcts. Imaging LA flow characteristics may aid identification of individuals who would benefit from anticoagulation for embolic stroke prevention, regardless of heart rhythm.
Collapse
Affiliation(s)
- Marco Spartera
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, United Kingdom; Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom.
| | - Antonio Stracquadanio
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, United Kingdom; Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom
| | - Guilherme Pessoa-Amorim
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, United Kingdom; Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom; CTSU Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| | - George Harston
- Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom
| | - Sara Mazzucco
- Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom; Wolfson Centre for Prevention of Stroke and Dementia, Nuffield Department of Clinical Neuroscience, Oxford, United Kingdom
| | - Victoria Young
- Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom
| | - Adam Von Ende
- CTSU Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| | - Aaron T Hess
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, United Kingdom
| | - Vanessa M Ferreira
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, United Kingdom; Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom
| | - James Kennedy
- Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, United Kingdom; Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom
| | - Barbara Casadei
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom
| | - Rohan S Wijesurendra
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom; University of Oxford Centre for Clinical Magnetic Resonance Research, Oxford, United Kingdom; Oxford University Hospital NHS Foundation Trust, Oxford, United Kingdom; CTSU Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
6
|
Hao Y, Závodszky G, Tersteeg C, Barzegari M, Hoekstra AG. Image-based flow simulation of platelet aggregates under different shear rates. PLoS Comput Biol 2023; 19:e1010965. [PMID: 37428797 PMCID: PMC10358939 DOI: 10.1371/journal.pcbi.1010965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 06/10/2023] [Indexed: 07/12/2023] Open
Abstract
Hemodynamics is crucial for the activation and aggregation of platelets in response to flow-induced shear. In this paper, a novel image-based computational model simulating blood flow through and around platelet aggregates is presented. The microstructure of aggregates was captured by two different modalities of microscopy images of in vitro whole blood perfusion experiments in microfluidic chambers coated with collagen. One set of images captured the geometry of the aggregate outline, while the other employed platelet labelling to infer the internal density. The platelet aggregates were modelled as a porous medium, the permeability of which was calculated with the Kozeny-Carman equation. The computational model was subsequently applied to study hemodynamics inside and around the platelet aggregates. The blood flow velocity, shear stress and kinetic force exerted on the aggregates were investigated and compared under 800 s-1, 1600 s-1 and 4000 s-1 wall shear rates. The advection-diffusion balance of agonist transport inside the platelet aggregates was also evaluated by local Péclet number. The findings show that the transport of agonists is not only affected by the shear rate but also significantly influenced by the microstructure of the aggregates. Moreover, large kinetic forces were found at the transition zone from shell to core of the aggregates, which could contribute to identifying the boundary between the shell and the core. The shear rate and the rate of elongation flow were investigated as well. The results imply that the emerging shapes of aggregates are highly correlated to the shear rate and the rate of elongation. The framework provides a way to incorporate the internal microstructure of the aggregates into the computational model and yields a better understanding of the hemodynamics and physiology of platelet aggregates, hence laying the foundation for predicting aggregation and deformation under different flow conditions.
Collapse
Affiliation(s)
- Yue Hao
- Computational Science Lab, Informatics Institute, Faculty of Science, University of Amsterdam, Amsterdam, The Netherlands
| | - Gábor Závodszky
- Computational Science Lab, Informatics Institute, Faculty of Science, University of Amsterdam, Amsterdam, The Netherlands
- Department of Hydrodynamic Systems, Budapest University of Technology and Economics, Budapest, Hungary
| | - Claudia Tersteeg
- Laboratory for Thrombosis Research, IRF Life Sciences, KU Leuven Campus Kulak Kortrijk, Kortrijk, Belgium
| | - Mojtaba Barzegari
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Alfons G Hoekstra
- Computational Science Lab, Informatics Institute, Faculty of Science, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
7
|
Guerrero-Hurtado M, Garcia-Villalba M, Gonzalo A, Martinez-Legazpi P, Kahn AM, McVeigh E, Bermejo J, Del Alamo JC, Flores O. Efficient multi-fidelity computation of blood coagulation under flow. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.05.29.542763. [PMID: 37398367 PMCID: PMC10312426 DOI: 10.1101/2023.05.29.542763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/04/2023]
Abstract
Clot formation is a crucial process that prevents bleeding, but can lead to severe disorders when imbalanced. This process is regulated by the coagulation cascade, a biochemical network that controls the enzyme thrombin, which converts soluble fibrinogen into the fibrin fibers that constitute clots. Coagulation cascade models are typically complex and involve dozens of partial differential equations (PDEs) representing various chemical species' transport, reaction kinetics, and diffusion. Solving these PDE systems computationally is challenging, due to their large size and multi-scale nature. We propose a multi-fidelity strategy to increase the efficiency of coagulation cascade simulations. Leveraging the slower dynamics of molecular diffusion, we transform the governing PDEs into ordinary differential equations (ODEs) representing the evolution of species concentrations versus blood residence time. We then Taylor-expand the ODE solution around the zero-diffusivity limit to obtain spatiotemporal maps of species concentrations in terms of the statistical moments of residence time, , and provide the governing PDEs for . This strategy replaces a high-fidelity system of N PDEs representing the coagulation cascade of N chemical species by N ODEs and p PDEs governing the residence time statistical moments. The multi-fidelity order( p ) allows balancing accuracy and computational cost, providing a speedup of over N/p compared to high-fidelity models. Using a simplified coagulation network and an idealized aneurysm geometry with a pulsatile flow as a benchmark, we demonstrate favorable accuracy for low-order models of p = 1 and p = 2. These models depart from the high-fidelity solution by under 16% ( p = 1) and 5% ( p = 2) after 20 cardiac cycles. The favorable accuracy and low computational cost of multi-fidelity models could enable unprecedented coagulation analyses in complex flow scenarios and extensive reaction networks. Furthermore, it can be generalized to advance our understanding of other systems biology networks affected by blood flow.
Collapse
|
8
|
Morphology, Connectivity, and Encoding Features of Tactile and Motor Representations of the Fingers in the Human Precentral and Postcentral Gyrus. J Neurosci 2023; 43:1572-1589. [PMID: 36717227 PMCID: PMC10008061 DOI: 10.1523/jneurosci.1976-21.2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 09/11/2022] [Accepted: 09/14/2022] [Indexed: 02/01/2023] Open
Abstract
Despite the tight coupling between sensory and motor processing for fine manipulation in humans, it is not yet totally clear which specific properties of the fingers are mapped in the precentral and postcentral gyrus. We used fMRI to compare the morphology, connectivity, and encoding of the motor and tactile finger representations (FRs) in the precentral and postcentral gyrus of 25 5-fingered participants (8 females). Multivoxel pattern and structural and functional connectivity analyses demonstrated the existence of distinct motor and tactile FRs within both the precentral and postcentral gyrus, integrating finger-specific motor and tactile information. Using representational similarity analysis, we found that the motor and tactile FRs in the sensorimotor cortex were described by the perceived structure of the hand better than by the actual hand anatomy or other functional models (finger kinematics, muscles synergies). We then studied a polydactyly individual (i.e., with a congenital 6-fingered hand) showing superior manipulation abilities and divergent anatomic-functional hand properties. The perceived hand model was still the best model for tactile representations in the precentral and postcentral gyrus, while finger kinematics better described motor representations in the precentral gyrus. We suggest that, under normal conditions (i.e., in subjects with a standard hand anatomy), the sensorimotor representations of the 5 fingers in humans converge toward a model of perceived hand anatomy, deviating from the real hand structure, as the best synthesis between functional and structural features of the hand.SIGNIFICANCE STATEMENT Distinct motor and tactile finger representations exist in both the precentral and postcentral gyrus, supported by a finger-specific pattern of anatomic and functional connectivity across modalities. At the representational level, finger representations reflect the perceived structure of the hand, which might result from an adapting process harmonizing (i.e., uniformizing) the encoding of hand function and structure in the precentral and postcentral gyrus. The same analyses performed in an extremely rare polydactyly subject showed that the emergence of such representational geometry is also found in neuromechanical variants with different hand anatomy and function. However, the harmonization process across the precentral and postcentral gyrus might not be possible because of divergent functional-structural properties of the hand and associated superior manipulation abilities.
Collapse
|
9
|
Zhu G, Modepalli S, Anand M, Li H. Computational modeling of hypercoagulability in COVID-19. Comput Methods Biomech Biomed Engin 2023; 26:338-349. [PMID: 36154346 DOI: 10.1080/10255842.2022.2124858] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Coronavirus disease 2019 (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has infected more than 100 million people worldwide and claimed millions of lives. While the leading cause of mortality in COVID-19 patients is the hypoxic respiratory failure from acute respiratory distress syndrome, there is accumulating evidence that shows excessive coagulation also increases the fatalities in COVID-19. Thus, there is a pressing demand to understand the association between COVID-19-induced hypercoagulability and the extent of formation of undesired blood clots. Mathematical modeling of coagulation has been used as an important tool to identify novel reaction mechanisms and to identify targets for new drugs. Here, we employ the coagulation factor data of COVID-19 patients reported from published studies as inputs for two mathematical models of coagulation to identify how the concentrations of coagulation factors change in these patients. Our simulation results show that while the levels of many of the abnormal coagulation factors measured in COVID-19 patients promote the generation of thrombin and fibrin, two key components of blood clots, the increased level of fibrinogen and then the reduced level of antithrombin are the factors most responsible for boosting the level of fibrin and thrombin, respectively. Altogether, our study demonstrates the potential of mathematical modeling to identify coagulation factors responsible for the increased clot formation in COVID-19 patients where clinical data is scarce.
Collapse
Affiliation(s)
- Ge Zhu
- Center for Biomedical Engineering, Brown University, Providence, USA
| | | | - Mohan Anand
- Department of Chemical Engineering, Indian Institute of Technology Hyderabad, Hyderabad, India
| | - He Li
- School of Chemical, Materials & Biomedical Engineering, University of Georgia, Athens, USA
| |
Collapse
|
10
|
Belyaev AV, Kushchenko YK. Biomechanical activation of blood platelets via adhesion to von Willebrand factor studied with mesoscopic simulations. Biomech Model Mechanobiol 2023; 22:785-808. [PMID: 36627458 PMCID: PMC9838538 DOI: 10.1007/s10237-022-01681-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 12/22/2022] [Indexed: 01/12/2023]
Abstract
Platelet adhesion and activation are essential initial processes of arterial and microvascular hemostasis, where high hydrodynamic forces from the bloodflow impede coagulation. The process relies on von Willebrand factor (VWF)-a linear multimeric protein of blood plasma plays a pivotal role in mechanochemical regulation of shear-induced platelet aggregation (SIPA). Adhesive interactions between VWF and glycoprotein receptors GPIb are crucial for platelet recruitment under high shear stress in fluid. Recent advances in experimental studies revealed that mechanical tension on the extracellular part of GPIb may trigger a cascade of biochemical reactions in platelets leading to activation of integrins [Formula: see text] (also known as GPIIb/IIIa) and strengthening of the adhesion. The present paper is aimed at investigation of this process by three-dimensional computer simulations of platelet adhesion to surface-grafted VWF multimers in pressure-driven flow of platelet-rich plasma. The simulations demonstrate that GPIb-mediated mechanotransduction is a feasible way of platelet activation and stabilization of platelet aggregates under high shear stress. Quantitative understanding of mechanochemical processes involved in SIPA would potentially promote the discovery of new anti-platelet medication and the development of multiscale numerical models of platelet thrombosis and hemostasis.
Collapse
Affiliation(s)
- Aleksey V. Belyaev
- grid.14476.300000 0001 2342 9668Faculty of Physics, M.V. Lomonosov Moscow State University, 1-2 Leninskiye Gory, Moscow, Russia 119991
| | - Yulia K. Kushchenko
- grid.14476.300000 0001 2342 9668Faculty of Physics, M.V. Lomonosov Moscow State University, 1-2 Leninskiye Gory, Moscow, Russia 119991
| |
Collapse
|
11
|
Choi JS, Ham DH, Kim JH, Marcial HBF, Jeong PH, Choi JH, Park WT. Quantitative image analysis of thrombus formation in microfluidic in-vitro models. MICRO AND NANO SYSTEMS LETTERS 2022. [DOI: 10.1186/s40486-022-00166-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
AbstractIn this study, we present a method to quantitatively analyze the thrombus formation process through image analysis in an in vitro thrombus model with a circular cross section. The thrombus model used was designed based on the mechanism between the physical principle of wall shear rate (WSR) and thrombus formation. Image analysis was used to help visualize the thrombus formation process and calculate the thrombus area. Through this method, the thrombus formation and growth from the channel wall was demonstrated without the use of fluorescence. In addition, by dividing the image into sub-sections, the accuracy of the thrombus growth pattern was improved. The departing blood clots which are called embolus, were observed being separated from the thrombus.
Collapse
|
12
|
Zhussupbekov M, Méndez Rojano R, Wu WT, Antaki JF. von Willebrand factor unfolding mediates platelet deposition in a model of high-shear thrombosis. Biophys J 2022; 121:4033-4047. [PMID: 36196057 PMCID: PMC9675031 DOI: 10.1016/j.bpj.2022.09.040] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 06/21/2022] [Accepted: 09/27/2022] [Indexed: 11/30/2022] Open
Abstract
Thrombosis under high-shear conditions is mediated by the mechanosensitive blood glycoprotein von Willebrand factor (vWF). vWF unfolds in response to strong flow gradients and facilitates rapid recruitment of platelets in flowing blood. While the thrombogenic effect of vWF is well recognized, its conformational response in complex flows has largely been omitted from numerical models of thrombosis. We recently presented a continuum model for the unfolding of vWF, where we represented vWF transport and its flow-induced conformational change using convection-diffusion-reaction equations. Here, we incorporate the vWF component into our multi-constituent model of thrombosis, where the local concentration of stretched vWF amplifies the deposition rate of free-flowing platelets and reduces the shear cleaning of deposited platelets. We validate the model using three benchmarks: in vitro model of atherothrombosis, a stagnation point flow, and the PFA-100, a clinical blood test commonly used for screening for von Willebrand disease (vWD). The simulations reproduced the key aspects of vWF-mediated thrombosis observed in these experiments, such as the thrombus location, thrombus growth dynamics, and the effect of blocking platelet-vWF interactions. The PFA-100 simulations closely matched the reported occlusion times for normal blood and several hemostatic deficiencies, namely, thrombocytopenia, vWD type 1, and vWD type 3. Overall, this multi-constituent model of thrombosis enables macro-scale 3D simulations of thrombus formation in complex geometries over a wide range of shear rates and accounts for qualitative and quantitative hemostatic deficiencies in patient blood.
Collapse
Affiliation(s)
- Mansur Zhussupbekov
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York
| | | | - Wei-Tao Wu
- Department of Aerospace Science and Technology, Nanjing University of Science and Technology, Nanjing, China
| | - James F Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York.
| |
Collapse
|
13
|
Wang Y, Luan J, Luo K, Fan J, Zhu T. Model reduction of coagulation cascade based on genetic algorithm. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3652. [PMID: 36167948 DOI: 10.1002/cnm.3652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 08/18/2022] [Accepted: 09/17/2022] [Indexed: 06/16/2023]
Abstract
Fibrin is an important product of the coagulation cascade, and plays an eminent role in platelet stabilization. Since coagulation cascade models typically involve the reaction kinetics of dozens of proteins, which will incur burdensome computational costs when coupled to blood flow in complex geometries, researchers often ignore this process when constructing thrombosis models. However, previous studies have shown that fundamental aspects of coagulation can be reproduced with simpler models, which motivated us to obtain a reduced-order model of fibrin generation through a systematic approach. Therefore, we introduced a semi-automatic framework to perform model-reduction of cascade reactions in this study, which consisted of two processes. Specifically, the retained protein species and cascade reactions were determined based on published studies and simulation results from the full cascade model, while the optimal reaction rates for the new cascade network were determined using a genetic algorithm. The framework has been applied to a 19-species coagulation model that triggers fibrin generation in internal fields via reactive boundaries, and a 10-species reduced-order model was obtained to reproduce the kinetics of fibrinogenesis in the full cascade model at different boundary tissue factor concentrations. This reduced-order model of fibrinogenesis would be valuable for thrombosis modeling that considers both the coagulation cascade and platelet activity. Furthermore, the framework proposed herein can also be applied to the reductions of other cascade reaction models.
Collapse
Affiliation(s)
- Yan Wang
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China
| | - Jingyang Luan
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Kun Luo
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China
| | - Jianren Fan
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China
| | - Ting Zhu
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
14
|
Méndez Rojano R, Lai A, Zhussupbekov M, Burgreen GW, Cook K, Antaki JF. A fibrin enhanced thrombosis model for medical devices operating at low shear regimes or large surface areas. PLoS Comput Biol 2022; 18:e1010277. [PMID: 36190991 PMCID: PMC9560616 DOI: 10.1371/journal.pcbi.1010277] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 10/13/2022] [Accepted: 09/15/2022] [Indexed: 11/06/2022] Open
Abstract
Over the past decade, much of the development of computational models of device-related thrombosis has focused on platelet activity. While those models have been successful in predicting thrombus formation in medical devices operating at high shear rates (> 5000 s−1), they cannot be directly applied to low-shear devices, such as blood oxygenators and catheters, where emerging information suggest that fibrin formation is the predominant mechanism of clotting and platelet activity plays a secondary role. In the current work, we augment an existing platelet-based model of thrombosis with a partial model of the coagulation cascade that includes contact activation of factor XII and fibrin production. To calibrate the model, we simulate a backward-facing-step flow channel that has been extensively characterized in-vitro. Next, we perform blood perfusion experiments through a microfluidic chamber mimicking a hollow fiber membrane oxygenator and validate the model against these observations. The simulation results closely match the time evolution of the thrombus height and length in the backward-facing-step experiment. Application of the model to the microfluidic hollow fiber bundle chamber capture both gross features such as the increasing clotting trend towards the outlet of the chamber, as well as finer local features such as the structure of fibrin around individual hollow fibers. Our results are in line with recent findings that suggest fibrin production, through contact activation of factor XII, drives the thrombus formation in medical devices operating at low shear rates with large surface area to volume ratios. Patients treated with blood-contacting medical devices suffer from clotting complications. Over the past decades, a great effort has been made to develop computational tools to predict and prevent clot formation in these devices. However, most models have focused on platelet activity and neglected other important parts of the problem such as the coagulation cascade reactions that lead to fibrin formation. In the current work, we incorporate this missing element into a well-established and validated model for platelet activity. We then use this novel approach to predict thrombus formation in two experimental configurations. Our results confirm that to accurately predict the clotting process in devices where surface area to volume ratios are large and flow velocity and shear stresses remain low, coagulation reactions and subsequent fibrin formation must be considered. This new model could have great implications for the design and optimization of medical devices such as blood oxygenators. In the long term, the model could evolve into a functional tool to inform anticoagulation therapies for these patients.
Collapse
Affiliation(s)
- Rodrigo Méndez Rojano
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, United States of America
- * E-mail:
| | - Angela Lai
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, United States of America
| | - Mansur Zhussupbekov
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, United States of America
| | - Greg W. Burgreen
- Center for Advanced Vehicular Systems, Mississippi State University, Starkville, Mississippi, United States of America
| | - Keith Cook
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, United States of America
| | - James F. Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, United States of America
| |
Collapse
|
15
|
Akther F, Zhang J, Tran HDN, Fallahi H, Adelnia H, Phan HP, Nguyen NT, Ta HT. Atherothrombosis-on-Chip: A Site-Specific Microfluidic Model for Thrombus Formation and Drug Discovery. Adv Biol (Weinh) 2022; 6:e2101316. [PMID: 35666057 DOI: 10.1002/adbi.202101316] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 05/06/2022] [Indexed: 01/28/2023]
Abstract
Atherothrombosis, an atherosclerotic plaque disruption condition with superimposed thrombosis, is the underlying cause of cardiovascular episodes. Herein, a unique design is presented to develop a microfluidic site-specific atherothrombosis-on-chip model, providing a universal platform for studying the crosstalk between blood cells and plaque components. The device consists of two interconnected microchannels, namely main and supporting channels: the former mimics the vessel geometry with different stenosis, and the latter introduces plaque components to the circulation simultaneously. The unique design allows the site-specific introduction of plaque components in stenosed channels ranging from 0% to above 50%, resulting in thrombosis, which has not been achieved previously. The device successfully explains the correlation between vessel geometry and thrombus formation phenomenon as well as the influence of shear rate on platelet aggregation, confirming the reliability and the effectiveness of the design. The device exhibits significant sensitivity to aspirin. In therapeutic doses (50 × 10-6 and 100 × 10-6 m), aspirin delays and prevents platelet adhesion, thereby reducing the thrombus area in a dose-dependent manner. Finally, the device is effectively employed in testing the targeted binding of the RGD (arginyl-glycyl-aspartic acid) labeled polymeric nanoparticles on the thrombus, extending the use of the device to examine targeted drug carriers.
Collapse
Affiliation(s)
- Fahima Akther
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia
| | - Jun Zhang
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Huong D N Tran
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia
| | - Hedieh Fallahi
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Hossein Adelnia
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia
| | - Hoang-Phuong Phan
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia
| | - Hang Thu Ta
- Queensland Micro- and Nanotechnology, Griffith University, Nathan, Queensland, 4111, Australia.,Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, Queensland, 4072, Australia.,School of Environment and Science, Griffith University, Nathan, Queensland, 4111, Australia
| |
Collapse
|
16
|
Aghilinejad A, Wei H, Magee GA, Pahlevan NM. Model-Based Fluid-Structure Interaction Approach for Evaluation of Thoracic Endovascular Aortic Repair Endograft Length in Type B Aortic Dissection. Front Bioeng Biotechnol 2022; 10:825015. [PMID: 35813993 PMCID: PMC9259938 DOI: 10.3389/fbioe.2022.825015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 05/11/2022] [Indexed: 11/26/2022] Open
Abstract
Thoracic endovascular aortic repair (TEVAR) is a commonly performed operation for patients with type B aortic dissection (TBAD). The goal of TEVAR is to cover the proximal entry tear between the true lumen (TL) and the false lumen (FL) with an endograft to induce FL thrombosis, allow for aortic healing, and decrease the risk of aortic aneurysm and rupture. While TEVAR has shown promising outcomes, it can also result in devastating complications including stroke, spinal cord ischemia resulting in paralysis, as well as long-term heart failure, so treatment remains controversial. Similarly, the biomechanical impact of aortic endograft implantation and the hemodynamic impact of endograft design parameters such as length are not well-understood. In this study, a fluid-structure interaction (FSI) computational fluid dynamics (CFD) approach was used based on the immersed boundary and Lattice–Boltzmann method to investigate the association between the endograft length and hemodynamic variables inside the TL and FL. The physiological accuracy of the model was evaluated by comparing simulation results with the true pressure waveform measurements taken during a live TEVAR operation for TBAD. The results demonstrate a non-linear trend towards increased FL flow reversal as the endograft length increases but also increased left ventricular pulsatile workload. These findings suggest a medium-length endograft may be optimal by achieving FL flow reversal and thus FL thrombosis, while minimizing the extra load on the left ventricle. These results also verify that a reduction in heart rate with medical therapy contributes favorably to FL flow reversal.
Collapse
Affiliation(s)
- Arian Aghilinejad
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, United States
| | - Heng Wei
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, United States
| | - Gregory A. Magee
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, United States
| | - Niema M. Pahlevan
- Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, United States
- Division of Cardiovascular Medicine, Department of Medicine, University of Southern California, Los Angeles, CA, United States
- *Correspondence: Niema M. Pahlevan,
| |
Collapse
|
17
|
Numerical investigation of abdominal aortic aneurysm hemodynamics using the reduced unified continuum formulation for vascular fluid-structure interaction. FORCES IN MECHANICS 2022. [DOI: 10.1016/j.finmec.2022.100089] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
18
|
Méndez Rojano R, Zhussupbekov M, Antaki JF, Lucor D. Uncertainty quantification of a thrombosis model considering the clotting assay PFA-100®. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3595. [PMID: 35338596 DOI: 10.1002/cnm.3595] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 02/11/2022] [Accepted: 03/17/2022] [Indexed: 06/14/2023]
Abstract
Mathematical models of thrombosis are currently used to study clinical scenarios of pathological thrombus formation. As these models become more complex to predict thrombus formation dynamics high computational cost must be alleviated and inherent uncertainties must be assessed. Evaluating model uncertainties allows to increase the confidence in model predictions and identify avenues of improvement for both thrombosis modeling and anti-platelet therapies. In this work, an uncertainty quantification analysis of a multi-constituent thrombosis model is performed considering a common assay for platelet function (PFA-100®). The analysis is facilitated thanks to time-evolving polynomial chaos expansions used as a parametric surrogate for the full thrombosis model considering two quantities of interest; namely, thrombus volume and occlusion percentage. The surrogate is thoroughly validated and provides a straightforward access to a global sensitivity analysis via computation of Sobol' coefficients. Six out of 15 parameters linked to thrombus consitution, vWF activity, and platelet adhesion dynamics were found to be most influential in the simulation variability considering only individual effects; while parameter interactions are highlighted when considering the total Sobol' indices. The influential parameters are related to thrombus constitution, vWF activity, and platelet to platelet adhesion dynamics. The surrogate model allowed to predict realistic PFA-100® closure times of 300,000 virtual cases that followed the trends observed in clinical data. The current methodology could be used including common anti-platelet therapies to identify scenarios that preserve the hematological balance.
Collapse
Affiliation(s)
| | - Mansur Zhussupbekov
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - James F Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York, USA
| | - Didier Lucor
- Laboratoire Interdisciplinaire des Sciences du Numérique, CNRS, Université Paris-Saclay, Orsay, France
| |
Collapse
|
19
|
Multiphysics and multiscale modeling of microthrombosis in COVID-19. PLoS Comput Biol 2022; 18:e1009892. [PMID: 35255089 PMCID: PMC8901059 DOI: 10.1371/journal.pcbi.1009892] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 02/02/2022] [Indexed: 12/21/2022] Open
Abstract
Emerging clinical evidence suggests that thrombosis in the microvasculature of patients with Coronavirus disease 2019 (COVID-19) plays an essential role in dictating the disease progression. Because of the infectious nature of SARS-CoV-2, patients’ fresh blood samples are limited to access for in vitro experimental investigations. Herein, we employ a novel multiscale and multiphysics computational framework to perform predictive modeling of the pathological thrombus formation in the microvasculature using data from patients with COVID-19. This framework seamlessly integrates the key components in the process of blood clotting, including hemodynamics, transport of coagulation factors and coagulation kinetics, blood cell mechanics and adhesive dynamics, and thus allows us to quantify the contributions of many prothrombotic factors reported in the literature, such as stasis, the derangement in blood coagulation factor levels and activities, inflammatory responses of endothelial cells and leukocytes to the microthrombus formation in COVID-19. Our simulation results show that among the coagulation factors considered, antithrombin and factor V play more prominent roles in promoting thrombosis. Our simulations also suggest that recruitment of WBCs to the endothelial cells exacerbates thrombogenesis and contributes to the blockage of the blood flow. Additionally, we show that the recent identification of flowing blood cell clusters could be a result of detachment of WBCs from thrombogenic sites, which may serve as a nidus for new clot formation. These findings point to potential targets that should be further evaluated, and prioritized in the anti-thrombotic treatment of patients with COVID-19. Altogether, our computational framework provides a powerful tool for quantitative understanding of the mechanism of pathological thrombus formation and offers insights into new therapeutic approaches for treating COVID-19 associated thrombosis. Emerging clinical evidence suggests that thrombosis in the microvasculature of patients with Coronavirus disease 2019 (COVID-19) plays an essential role in dictating the disease progression. We employ a novel multiphysics and multiscale computational framework to investigate the underlying mechanism of the pathological formation of microthrombi and circulating cell clusters in COVID-19. We quantify the contributions of many prothrombotic factors reported in the literature, such as stasis, the derangement in blood coagulation factor levels and activities, inflammatory responses of endothelial cells and leukocytes to the microthrombus formation in COVID-19, through which we identify the potential targets that should be further evaluated, and prioritized in the anti-thrombotic treatment of patients with COVID-19.
Collapse
|
20
|
Deng YX, Chang HY, Li H. Recent Advances in Computational Modeling of Biomechanics and Biorheology of Red Blood Cells in Diabetes. Biomimetics (Basel) 2022; 7:15. [PMID: 35076493 PMCID: PMC8788472 DOI: 10.3390/biomimetics7010015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/01/2022] [Accepted: 01/08/2022] [Indexed: 02/06/2023] Open
Abstract
Diabetes mellitus, a metabolic disease characterized by chronically elevated blood glucose levels, affects about 29 million Americans and more than 422 million adults all over the world. Particularly, type 2 diabetes mellitus (T2DM) accounts for 90-95% of the cases of vascular disease and its prevalence is increasing due to the rising obesity rates in modern societies. Although multiple factors associated with diabetes, such as reduced red blood cell (RBC) deformability, enhanced RBC aggregation and adhesion to the endothelium, as well as elevated blood viscosity are thought to contribute to the hemodynamic impairment and vascular occlusion, clinical or experimental studies cannot directly quantify the contributions of these factors to the abnormal hematology in T2DM. Recently, computational modeling has been employed to dissect the impacts of the aberrant biomechanics of diabetic RBCs and their adverse effects on microcirculation. In this review, we summarize the recent advances in the developments and applications of computational models in investigating the abnormal properties of diabetic blood from the cellular level to the vascular level. We expect that this review will motivate and steer the development of new models in this area and shift the attention of the community from conventional laboratory studies to combined experimental and computational investigations, aiming to provide new inspirations for the development of advanced tools to improve our understanding of the pathogenesis and pathology of T2DM.
Collapse
Affiliation(s)
- Yi-Xiang Deng
- School of Engineering, Brown University, Providence, RI 02912, USA;
| | - Hung-Yu Chang
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA;
| | - He Li
- Center for Biomedical Engineering, Brown University, Providence, RI 02912, USA
| |
Collapse
|
21
|
Li H, Deng Y, Sampani K, Cai S, Li Z, Sun JK, Karniadakis GE. Computational investigation of blood cell transport in retinal microaneurysms. PLoS Comput Biol 2022; 18:e1009728. [PMID: 34986147 PMCID: PMC8730408 DOI: 10.1371/journal.pcbi.1009728] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 12/07/2021] [Indexed: 12/15/2022] Open
Abstract
Microaneurysms (MAs) are one of the earliest clinically visible signs of diabetic retinopathy (DR). MA leakage or rupture may precipitate local pathology in the surrounding neural retina that impacts visual function. Thrombosis in MAs may affect their turnover time, an indicator associated with visual and anatomic outcomes in the diabetic eyes. In this work, we perform computational modeling of blood flow in microchannels containing various MAs to investigate the pathologies of MAs in DR. The particle-based model employed in this study can explicitly represent red blood cells (RBCs) and platelets as well as their interaction in the blood flow, a process that is very difficult to observe in vivo. Our simulations illustrate that while the main blood flow from the parent vessels can perfuse the entire lumen of MAs with small body-to-neck ratio (BNR), it can only perfuse part of the lumen in MAs with large BNR, particularly at a low hematocrit level, leading to possible hypoxic conditions inside MAs. We also quantify the impacts of the size of MAs, blood flow velocity, hematocrit and RBC stiffness and adhesion on the likelihood of platelets entering MAs as well as their residence time inside, two factors that are thought to be associated with thrombus formation in MAs. Our results show that enlarged MA size, increased blood velocity and hematocrit in the parent vessel of MAs as well as the RBC-RBC adhesion promote the migration of platelets into MAs and also prolong their residence time, thereby increasing the propensity of thrombosis within MAs. Overall, our work suggests that computational simulations using particle-based models can help to understand the microvascular pathology pertaining to MAs in DR and provide insights to stimulate and steer new experimental and computational studies in this area.
Collapse
Affiliation(s)
- He Li
- School of Engineering, Brown University, Providence, Rhode Island, United States of America
| | - Yixiang Deng
- School of Engineering, Brown University, Providence, Rhode Island, United States of America
| | - Konstantina Sampani
- Beetham Eye Institute, Joslin Diabetes Center, Boston, Massachusetts, United States of America
- Department of Medicine, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Shengze Cai
- Division of Applied Mathematics, Brown University, Providence, Rhode Island, United States of America
| | - Zhen Li
- Department of Mechanical Engineering, Clemson University, Clemson, South Carolina, United States of America
| | - Jennifer K. Sun
- Beetham Eye Institute, Joslin Diabetes Center, Boston, Massachusetts, United States of America
- Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, United States of America
| | - George E. Karniadakis
- School of Engineering, Brown University, Providence, Rhode Island, United States of America
- Division of Applied Mathematics, Brown University, Providence, Rhode Island, United States of America
| |
Collapse
|
22
|
Shankar KN, Zhang Y, Sinno T, Diamond SL. A three-dimensional multiscale model for the prediction of thrombus growth under flow with single-platelet resolution. PLoS Comput Biol 2022; 18:e1009850. [PMID: 35089923 PMCID: PMC8827456 DOI: 10.1371/journal.pcbi.1009850] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 02/09/2022] [Accepted: 01/18/2022] [Indexed: 11/18/2022] Open
Abstract
Modeling thrombus growth in pathological flows allows evaluation of risk under patient-specific pharmacological, hematological, and hemodynamical conditions. We have developed a 3D multiscale framework for the prediction of thrombus growth under flow on a spatially resolved surface presenting collagen and tissue factor (TF). The multiscale framework is composed of four coupled modules: a Neural Network (NN) that accounts for platelet signaling, a Lattice Kinetic Monte Carlo (LKMC) simulation for tracking platelet positions, a Finite Volume Method (FVM) simulator for solving convection-diffusion-reaction equations describing agonist release and transport, and a Lattice Boltzmann (LB) flow solver for computing the blood flow field over the growing thrombus. A reduced model of the coagulation cascade was embedded into the framework to account for TF-driven thrombin production. The 3D model was first tested against in vitro microfluidics experiments of whole blood perfusion with various antiplatelet agents targeting COX-1, P2Y1, or the IP receptor. The model was able to accurately capture the evolution and morphology of the growing thrombus. Certain problems of 2D models for thrombus growth (artifactual dendritic growth) were naturally avoided with realistic trajectories of platelets in 3D flow. The generalizability of the 3D multiscale solver enabled simulations of important clinical situations, such as cylindrical blood vessels and acute flow narrowing (stenosis). Enhanced platelet-platelet bonding at pathologically high shear rates (e.g., von Willebrand factor unfolding) was required for accurately describing thrombus growth in stenotic flows. Overall, the approach allows consideration of patient-specific platelet signaling and vascular geometry for the prediction of thrombotic episodes. The excessive formation of blood clots under flow within the circulatory system (thrombosis) is known to initiate heart attacks and strokes. Therefore, obtaining insights into the formation and progression of these clots will be useful in evaluating pharmacological options. To this end, we have developed a 3D computational model that tracks the growth of a blood clot under flow from initial platelet deposition to full vessel occlusion in the presence of soluble platelet agonists. We first validated the model against experimental predictions of blood clots formed in vitro. Due to the construction of the model in 3D, we were able to carry out simulations of clot formation under important clinical situations, namely cylindrical blood vessels and acute flow narrowings (stenoses). To our knowledge, our model is the first of its kind that can account for patient-specific platelet phenotypes to perform robust 3D simulations of thrombus growth in geometries of clinical relevance.
Collapse
Affiliation(s)
- Kaushik N. Shankar
- Department of Chemical and Biomolecular Engineering, Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Yiyuan Zhang
- Department of Chemical and Biomolecular Engineering, Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Talid Sinno
- Department of Chemical and Biomolecular Engineering, Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Scott L. Diamond
- Department of Chemical and Biomolecular Engineering, Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
- * E-mail:
| |
Collapse
|
23
|
Hatoum H, Gooden SCM, Sathananthan J, Sellers S, Kutting M, Marx P, Lilly SM, Ihdayhid AR, Thourani VH, Dasi LP. Neosinus and Sinus Flow After Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv 2021; 14:2657-2666. [PMID: 34838462 DOI: 10.1016/j.jcin.2021.09.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/10/2021] [Accepted: 09/14/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate flow dynamics in the aortic sinus and the neosinus (NS) after transcatheter heart valve (THV) implantation in valve-in-valve (ViV). BACKGROUND Leaflet thrombosis may occur on THVs and affect performance and durability. Differences in flow dynamics may affect the risk for leaflet thrombosis. METHODS Hemodynamic assessment following THV implantation in a surgical aortic valve was performed in a left heart simulator under pulsatile physiological conditions. Assessment was performed using a 23-mm polymeric surgical aortic valve (not diseased) and multiple THV platforms, including self-expanding devices (26-mm Evolut, 23-mm Allegra, small ACURATE neo) and a balloon-expandable device (23-mm SAPIEN 3). Particle image velocimetry was performed to assess flow in the sinus and NS. Sinus and NS washout, shear stress, and velocity were calculated. RESULTS Sinus and NS washout was fastest and approximately 1 cardiac cycle for each with the Evolut, ACURATE neo, and Allegra compared with the SAPIEN 3, with washout in 2 and 3 cardiac cycles, respectively. The Allegra showed the largest shear stress distribution in the sinus, followed by the SAPIEN 3. In the NS, all 4 valves showed equal likelihoods of occurrence of shear stress <1 Pa, but the Allegra showed the highest likelihoods of occurrence for shear stress >1 Pa. The velocities in the sinus and NS were 0.05, 0.078, 0.080, and 0.075 m/s for Evolut, SAPIEN 3, ACURATE neo, and Allegra ViV, respectively. CONCLUSIONS Sinus and NS flow dynamics differ substantially among THVs after ViV. Self-expanding supra-annular valves seem to have faster washouts compared with an equivalent-size balloon-expandable THV.
Collapse
Affiliation(s)
- Hoda Hatoum
- Biomedical Engineering Department, Michigan Technological University, Houghton, Michigan, USA; Health Research Institute, Houghton, Michigan, USA; Center for Biocomputing and Digital Health, Michigan Technological University, Houghton, Michigan, USA.
| | - Shelley C M Gooden
- Biomedical Engineering Department, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Janarthanan Sathananthan
- Center for Cardiovascular Innovation, Cardiovascular Translational Laboratory, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | - Stephanie Sellers
- Center for Cardiovascular Innovation, Cardiovascular Translational Laboratory, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
| | | | | | - Scott M Lilly
- Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
| | - Abdul R Ihdayhid
- Fiona Stanley Hospital, Harry Perkins Institute of Medical Research, Perth, Australia
| | - Vinod H Thourani
- Department of Cardiovascular Surgery, Marcus Valve Center, Piedmont Heart Institute, Atlanta, Georgia, USA
| | - Lakshmi Prasad Dasi
- Biomedical Engineering Department, Georgia Institute of Technology, Atlanta, Georgia, USA
| |
Collapse
|
24
|
Spartera M, Stracquadanio A, Pessoa-Amorim G, Von Ende A, Fletcher A, Manley P, Ferreira VM, Hess AT, Hopewell JC, Neubauer S, Wijesurendra RS, Casadei B. The impact of atrial fibrillation and stroke risk factors on left atrial blood flow characteristics. Eur Heart J Cardiovasc Imaging 2021; 23:115-123. [PMID: 34687541 PMCID: PMC8685601 DOI: 10.1093/ehjci/jeab213] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 10/06/2021] [Indexed: 12/03/2022] Open
Abstract
AIMS Altered left atrial (LA) blood flow characteristics account for an increase in cardioembolic stroke risk in atrial fibrillation (AF). Here, we aimed to assess whether exposure to stroke risk factors is sufficient to alter LA blood flow even in the presence of sinus rhythm (SR). METHODS AND RESULTS We investigated 95 individuals: 37 patients with persistent AF, who were studied before and after cardioversion [Group 1; median CHA2DS2-VASc = 2.0 (1.5-3.5)]; 35 individuals with no history of AF but similar stroke risk to Group 1 [Group 2; median CHA2DS2-VASc = 3.0 (2.0-4.0)]; and 23 low-risk individuals in SR [Group 3; median CHA2DS2-VASc = 0.0 (0.0-0.0)]. Cardiac function and LA flow characteristics were evaluated using cardiac magnetic resonance. Before cardioversion, Group 1 displayed impaired left ventricular (LV) and LA function, reduced LA flow velocities and vorticity, and a higher normalized vortex volume (all P < 0.001 vs. Groups 2 and 3). After restoration of SR at ≥4-week post-cardioversion, LV systolic function and LA flow parameters improved significantly (all P < 0.001 vs. pre-cardioversion) and were no longer different from those in Group 2. However, in the presence of SR, LA flow peak and mean velocity, and vorticity were lower in Groups 1 and 2 vs. Group 3 (all P < 0.01), and were associated with impaired LA emptying fraction (LAEF) and LV diastolic dysfunction. CONCLUSION Patients at moderate-to-high stroke risk display altered LA flow characteristics in SR in association with an LA myopathic phenotype and LV diastolic dysfunction, regardless of a history of AF.
Collapse
Affiliation(s)
- Marco Spartera
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Level 6, West Wing, Headley Way, Oxford OX3 9DU, UK
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford, UK
| | - Antonio Stracquadanio
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Level 6, West Wing, Headley Way, Oxford OX3 9DU, UK
| | - Guilherme Pessoa-Amorim
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Level 6, West Wing, Headley Way, Oxford OX3 9DU, UK
| | - Adam Von Ende
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Alison Fletcher
- Acute Vascular Imaging Centre, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Peter Manley
- Acute Vascular Imaging Centre, Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Vanessa M Ferreira
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Level 6, West Wing, Headley Way, Oxford OX3 9DU, UK
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford, UK
| | - Aaron T Hess
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford, UK
| | - Jemma C Hopewell
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Level 6, West Wing, Headley Way, Oxford OX3 9DU, UK
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford, UK
| | - Rohan S Wijesurendra
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Level 6, West Wing, Headley Way, Oxford OX3 9DU, UK
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, Oxford, UK
| | - Barbara Casadei
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Level 6, West Wing, Headley Way, Oxford OX3 9DU, UK
| |
Collapse
|
25
|
Beris AN, Horner JS, Jariwala S, Armstrong MJ, Wagner NJ. Recent advances in blood rheology: a review. SOFT MATTER 2021; 17:10591-10613. [PMID: 34787149 DOI: 10.1039/d1sm01212f] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Due to the potential impact on the diagnosis and treatment of various cardiovascular diseases, work on the rheology of blood has significantly expanded in the last decade, both experimentally and theoretically. Experimentally, blood has been confirmed to demonstrate a variety of non-Newtonian rheological characteristics, including pseudoplasticity, viscoelasticity, and thixotropy. New rheological experiments and the development of more controlled experimental protocols on more extensive, broadly physiologically characterized, human blood samples demonstrate the sensitivity of aspects of hemorheology to several physiological factors. For example, at high shear rates the red blood cells elastically deform, imparting viscoelasticity, while at low shear rates, they form "rouleaux" structures that impart additional, thixotropic behavior. In addition to the advances in experimental methods and validated data sets, significant advances have also been made in both microscopic simulations and macroscopic, continuum, modeling, as well as novel, multiscale approaches. We outline and evaluate the most promising of these recent developments. Although we primarily focus on human blood rheology, we also discuss recent observations on variations observed across some animal species that provide some indication on evolutionary effects.
Collapse
Affiliation(s)
- Antony N Beris
- Center for Research in Soft Matter and Polymers, Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716, USA.
| | - Jeffrey S Horner
- Center for Research in Soft Matter and Polymers, Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716, USA.
| | - Soham Jariwala
- Center for Research in Soft Matter and Polymers, Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716, USA.
| | - Matthew J Armstrong
- Department of Chemistry and Life Science, Chemical Engineering Program, United States Military Academy, West Point, NY 10996, USA
| | - Norman J Wagner
- Center for Research in Soft Matter and Polymers, Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716, USA.
| |
Collapse
|
26
|
Manning KB, Nicoud F, Shea SM. Mathematical and Computational Modeling of Device-Induced Thrombosis. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2021; 20:100349. [PMID: 35071850 PMCID: PMC8769491 DOI: 10.1016/j.cobme.2021.100349] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Given the extensive and routine use of cardiovascular devices, a major limiting factor to their success is the thrombotic rate that occurs. This both poses direct risk to the patient and requires counterbalancing with anticoagulation and other treatment strategies, contributing additional risks. Developing a better understanding of the mechanisms of device-induced thrombosis to aid in device design and medical management of patients is critical to advance the ubiquitous use and durability. Thus, mathematical and computational modelling of device-induced thrombosis has received significant attention recently, but challenges remain. Additional areas that need to be explored include microscopic/macroscopic approaches, reconciling physical and numerical timescales, immune/inflammatory responses, experimental validation, and incorporating pathologies and blood conditions. Addressing these areas will provide engineers and clinicians the tools to provide safe and effective cardiovascular devices.
Collapse
Affiliation(s)
- Keefe B. Manning
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA, USA
| | - Franck Nicoud
- CNRS, IMAG, Université de Montpellier, Montpellier, France
| | - Susan M. Shea
- Division of Critical Care Medicine, Department of Pediatrics, Washington University School of Medicine, St. Louis, MO, USA
| |
Collapse
|
27
|
Owen DG, de Oliveira DC, Neale EK, Shepherd DET, Espino DM. Numerical modelling of blood rheology and platelet activation through a stenosed left coronary artery bifurcation. PLoS One 2021; 16:e0259196. [PMID: 34731193 PMCID: PMC8565790 DOI: 10.1371/journal.pone.0259196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 10/14/2021] [Indexed: 01/09/2023] Open
Abstract
Coronary bifurcations are prone to atherosclerotic plaque growth, experiencing regions of reduced wall shear stress (WSS) and increased platelet adhesion. This study compares effects across different rheological approaches on hemodynamics, combined with a shear stress exposure history model of platelets within a stenosed porcine bifurcation. Simulations used both single/multiphase blood models to determine which approach best predicts phenomena associated with atherosclerosis and atherothrombosis. A novel Lagrangian platelet tracking model was used to evaluate residence time and shear history of platelets indicating likely regions of thrombus formation. Results show a decrease in area of regions with pathologically low time-averaged WSS with the use of multiphase models, particularly in a stenotic bifurcation. Significant non-Newtonian effects were observed due to low-shear and varying hematocrit levels found on the outer walls of the bifurcation and distal to the stenosis. Platelet residence time increased 11% in the stenosed artery, with exposure times to low-shear sufficient for red blood cell aggregation (>1.5 s). increasing the risk of thrombosis. This shows stenotic artery hemodynamics are inherently non-Newtonian and multiphase, with variations in hematocrit (0.163-0.617) and elevated vorticity distal to stenosis (+15%) impairing the function of the endothelium via reduced time-averaged WSS regions, rheological properties and platelet activation/adhesion.
Collapse
Affiliation(s)
- David G. Owen
- Department of Mechanical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Diana C. de Oliveira
- Department of Mechanical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Emma K. Neale
- Department of Mechanical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Duncan E. T. Shepherd
- Department of Mechanical Engineering, University of Birmingham, Birmingham, United Kingdom
| | - Daniel M. Espino
- Department of Mechanical Engineering, University of Birmingham, Birmingham, United Kingdom
| |
Collapse
|
28
|
Abstract
Distinct from dilute, isotropic, and homogeneous reaction systems typically used in laboratory kinetic assays, blood is concentrated, two-phase, flowing, and highly anisotropic when clotting on a surface. This review focuses on spatial gradients that are generated and can dictate thrombus structure and function. Novel experimental and computational tools have recently emerged to explore reaction-transport coupling during clotting. Multiscale simulations help bridge tissue length scales (the coronary arteries) to millimeter scales of a growing clot to the microscopic scale of single-cell signaling and adhesion. Microfluidic devices help create and control pathological velocity profiles, albeit at a low Reynolds number. Since rate processes and force loading are often coupled, this review highlights prevailing convective-diffusive transport physics that modulate cellular and molecular processes during thrombus formation.
Collapse
|
29
|
Teeraratkul C, Mukherjee D. Microstructure aware modeling of biochemical transport in arterial blood clots. J Biomech 2021; 127:110692. [PMID: 34479090 DOI: 10.1016/j.jbiomech.2021.110692] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 07/14/2021] [Accepted: 08/09/2021] [Indexed: 01/29/2023]
Abstract
Flow-mediated transport of biochemical species is central to thrombotic phenomena. Comprehensive three-dimensional modeling of flow-mediated transport around realistic macroscale thrombi poses challenges owing to their arbitrary heterogeneous microstructure. Here, we develop a microstructure aware model for species transport within and around a macroscale thrombus by devising a custom preconditioned fictitious domain formulation for thrombus-hemodynamics interactions, and coupling it with a fictitious domain advection-diffusion formulation for transport. Microstructural heterogeneities are accounted through a hybrid discrete particle-continuum approach for the thrombus interior. We present systematic numerical investigations on unsteady arterial flow within and around a three-dimensional macroscale thrombus; demonstrate the formation of coherent flow structures around the thrombus which organize advective transport; illustrate the role of the permeation processes at the thrombus boundary and subsequent intra-thrombus transport; and characterize species transport from bulk flow to the thrombus boundary and vice versa.
Collapse
Affiliation(s)
- Chayut Teeraratkul
- Paul M Rady Department of Mechanical Engineering, University of Colorado Boulder, United States of America.
| | - Debanjan Mukherjee
- Paul M Rady Department of Mechanical Engineering, University of Colorado Boulder, United States of America.
| |
Collapse
|
30
|
Masalceva AA, Kaneva VN, Panteleev MA, Ataullakhanov F, Volpert V, Afanasyev I, Nechipurenko DY. Analysis of microvascular thrombus mechanobiology with a novel particle-based model. J Biomech 2021; 130:110801. [PMID: 34768079 DOI: 10.1016/j.jbiomech.2021.110801] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 08/20/2021] [Accepted: 09/16/2021] [Indexed: 11/18/2022]
Abstract
Platelet accumulation at the site of a vascular injury is regulated by soluble platelet agonists, which induce various types of platelet responses, including integrin activation and granule secretion. The interplay between local biochemical cues, mechanical interactions between platelets and macroscopic thrombus dynamics is poorly understood. Here we describe a novel computational model of microvascular clot formation for the detailed analysis of thrombus mechanics. We adopt a previously developed two-dimensional particle-based model focused on the thrombus shell formation and revise it to introduce the platelet agonists. Blood flow is simulated via a computational fluid dynamics approach. In order to model soluble platelet activators, we apply Langevin dynamics to a large number of non-dimensional virtual particles. Taking advantage of the available data on platelet dense granule secretion kinetics, we model platelet degranulation as a stochastic agonist-dependent process. The new model qualitatively reproduces the enhanced thrombus formation due to dense granule secretion, in line with in vivo findings, and provides a mechanism for the thrombin confinement at the early stages of clot formation. Our calculations also predict that the release of platelet dense granules results in the additional mechanical stabilization of the inner layers of thrombus. Distribution of the inter-platelet forces throughout the aggregate reveals multiple weak spots in the outer regions of a thrombus, which are expected to result in the mechanical disruptions at the later stages of clot formation.
Collapse
Affiliation(s)
- Anastasia A Masalceva
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia; Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Science, Moscow, Russia
| | - Valeriia N Kaneva
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia; Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Science, Moscow, Russia; Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia
| | - Mikhail A Panteleev
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia; Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Science, Moscow, Russia; Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia; Faculty of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudnyi, Russia
| | - Fazoil Ataullakhanov
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia; Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Science, Moscow, Russia; Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia; Faculty of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudnyi, Russia
| | - Vitaly Volpert
- Institut Camille Jordan, UMR 5208 CNRS, University Lyon 1, 69622 Villeurbanne, France; INRIA Team Dracula, INRIA Lyon La Doua, 69603 Villeurbanne, France; Peoples' Friendship University of Russia (RUDN University), 6 Miklukho-Maklaya St, Moscow 117198, Russia
| | - Ilya Afanasyev
- Moscow Center of Fundamental and Applied Mathematics, Moscow, Russia; Research Computing Center of Moscow State University, Moscow, Russia
| | - Dmitry Yu Nechipurenko
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia; Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Science, Moscow, Russia; Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia.
| |
Collapse
|
31
|
Grande Gutiérrez N, Sinno T, Diamond SL. A 1D-3D Hybrid Model of Patient-Specific Coronary Hemodynamics. Cardiovasc Eng Technol 2021; 13:331-342. [PMID: 34591275 DOI: 10.1007/s13239-021-00580-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 09/07/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Coronary flow is affected by evolving events such as atherosclerotic plaque formation, rupture, and thrombosis, resulting in myocardial ischemia and infarction. Highly resolved 3D hemodynamic data at the stenosis is essential to model shear-sensitive thrombotic events in coronary artery disease. METHODS We developed a hybrid 1D-3D simulation framework to compute patient-specific coronary hemodynamics efficiently. A 1D model of the coronary flow is coupled to an image-based 3D model of the region of interest. This framework affords the advantages of reduced-order modeling, decreasing the global computational cost, without sacrificing the accuracy of the quantities of interest. RESULTS We validated our 1D-3D model against full 3D coronary simulations in healthy and diseased conditions. Our results showed good agreement between the 3D and the 1D-3D models while reducing the computational cost by 40-fold compared to the 3D simulation. The 1D-3D model predicted left/right coronary flow distribution within 3% and provided an accurate estimation of fractional flow reserve and wall shear stress distribution at the stenosis comparable to the 3D simulation. CONCLUSION Savings in computational cost may be significant in situations with changing geometry, such as growing thrombosis. Also, this approach would allow quantifying the time-dependent effect of thrombotic growth and occlusion on the global coronary circulation.
Collapse
Affiliation(s)
- Noelia Grande Gutiérrez
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, USA
| | - Talid Sinno
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, USA
| | - Scott L Diamond
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, USA. .,Department of Bioengineering, University of Pennsylvania, Philadelphia, USA.
| |
Collapse
|
32
|
Grande Gutiérrez N, Alber M, Kahn AM, Burns JC, Mathew M, McCrindle BW, Marsden AL. Computational modeling of blood component transport related to coronary artery thrombosis in Kawasaki disease. PLoS Comput Biol 2021; 17:e1009331. [PMID: 34491991 PMCID: PMC8448376 DOI: 10.1371/journal.pcbi.1009331] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 09/17/2021] [Accepted: 08/07/2021] [Indexed: 11/25/2022] Open
Abstract
Coronary artery thrombosis is the major risk associated with Kawasaki disease (KD). Long-term management of KD patients with persistent aneurysms requires a thrombotic risk assessment and clinical decisions regarding the administration of anticoagulation therapy. Computational fluid dynamics has demonstrated that abnormal KD coronary artery hemodynamics can be associated with thrombosis. However, the underlying mechanisms of clot formation are not yet fully understood. Here we present a new model incorporating data from patient-specific simulated velocity fields to track platelet activation and accumulation. We use a system of Reaction-Advection-Diffusion equations solved with a stabilized finite element method to describe the evolution of non-activated platelets and activated platelet concentrations [AP], local concentrations of adenosine diphosphate (ADP) and poly-phosphate (PolyP). The activation of platelets is modeled as a function of shear-rate exposure and local concentration of agonists. We compared the distribution of activated platelets in a healthy coronary case and six cases with coronary artery aneurysms caused by KD, including three with confirmed thrombosis. Results show spatial correlation between regions of higher concentration of activated platelets and the reported location of the clot, suggesting predictive capabilities of this model towards identifying regions at high risk for thrombosis. Also, the concentration levels of ADP and PolyP in cases with confirmed thrombosis are higher than the reported critical values associated with platelet aggregation (ADP) and activation of the intrinsic coagulation pathway (PolyP). These findings suggest the potential initiation of a coagulation pathway even in the absence of an extrinsic factor. Finally, computational simulations show that in regions of flow stagnation, biochemical activation, as a result of local agonist concentration, is dominant. Identifying the leading factors to a pro-coagulant environment in each case—mechanical or biochemical—could help define improved strategies for thrombosis prevention tailored for each patient. Computational studies aiming to model thrombosis often rely on an arterial wall injury. Collagen and other extracellular matrix components are exposed to the bloodstream, which facilitates platelet adhesion to the wall and subsequent clot formation. However, these models are not adequate to explain thrombosis in other settings where even in the absence of a focal lesion, clots may still form under certain flow conditions. Coronary artery aneurysm thrombosis following KD is an example of the need to understand the mechanisms of thrombus initiation in the absence of an extrinsic factor. This study provides a new framework to investigate thrombus initiation in KD from a patient-specific perspective, which integrates fluid mechanics and biochemistry and which could help quantify the pro-coagulant environment induced by the aneurysm and become a predictive tool. The work presented here has broad relevance to other clinical situations where flow stagnation and transport are driving factors in thrombus formation.
Collapse
Affiliation(s)
- Noelia Grande Gutiérrez
- Department of Mechanical Engineering, Stanford University, Stanford, California, United States of America
| | - Mark Alber
- Department of Mathematics and Interdisciplinary Center for Quantitative Modeling in Biology, University of California, Riverside, Riverside, California, United States of America
| | - Andrew M. Kahn
- Department of Medicine, University of California, San Diego, San Diego, California, United States of America
| | - Jane C. Burns
- Department of Pediatrics, University of California, San Diego, San Diego, California, United States of America
| | - Mathew Mathew
- The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Brian W. McCrindle
- The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Alison L. Marsden
- Department of Pediatrics, Bioengineering and Institute for Computational and Mathematical Engineering, Stanford University, Stanford, California, United States of America
- * E-mail:
| |
Collapse
|
33
|
Gupta P, Zhang P, Sheriff J, Bluestein D, Deng Y. A multiscale model for multiple platelet aggregation in shear flow. Biomech Model Mechanobiol 2021; 20:1013-1030. [PMID: 33782796 PMCID: PMC8274306 DOI: 10.1007/s10237-021-01428-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Accepted: 01/22/2021] [Indexed: 10/21/2022]
Abstract
We developed a multiscale model for simulating aggregation of multiple, free-flowing platelets in low-intermediate shear viscous flow, in which aggregation is mediated by the interaction of αIIbβ3 receptors on the platelet membrane and fibrinogen (Fg). This multiscale model uses coarse grained molecular dynamics (CGMD) for platelets at the microscales and dissipative particle dynamics (DPD) for the shear flow at the macroscales, employing our hybrid aggregation force field for modeling molecular level receptor ligand bonds. We define an aggregation tensor and use it to quantify the molecular level contact characteristics between platelets in an aggregate. We perform numerical studies under different flow conditions for platelet doublets and triplets and evaluate the contact area, detaching force and minimum distance between different pairs of platelets in an aggregate. We also present the dynamics of applied stress and velocity magnitude distributions on the platelet membrane during aggregation and quantify the increase in stress in the contact region under different flow conditions. Integrating the knowledge from our previously validated models, together with new aggregation scenarios, our model can dynamically quantify aggregation characteristics and map stress and velocity distribution on the platelet membrane which are difficult to measure in vitro, thus providing an insight into mechanotransduction bond formation response of platelets to flow-induced shear stresses. This modeling framework, together with the tensor method for quantifying inter-platelet contact, can be extended to simulate and analyze larger aggregates and their adhesive properties.
Collapse
Affiliation(s)
- Prachi Gupta
- Department of Applied Mathematics and Statistics, Stony Brook University, Stony Brook, NY, 11794, USA
| | - Peng Zhang
- Department of Applied Mathematics and Statistics, Stony Brook University, Stony Brook, NY, 11794, USA
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794, USA
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794, USA
| | - Yuefan Deng
- Department of Applied Mathematics and Statistics, Stony Brook University, Stony Brook, NY, 11794, USA.
| |
Collapse
|
34
|
Kaneva VN, Dunster JL, Volpert V, Ataullahanov F, Panteleev MA, Nechipurenko DY. Modeling Thrombus Shell: Linking Adhesion Receptor Properties and Macroscopic Dynamics. Biophys J 2021; 120:334-351. [PMID: 33472026 DOI: 10.1016/j.bpj.2020.10.049] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 09/10/2020] [Accepted: 10/15/2020] [Indexed: 02/06/2023] Open
Abstract
Damage to arterial vessel walls leads to the formation of platelet aggregate, which acts as a physical obstacle for bleeding. An arterial thrombus is heterogeneous; it has a dense inner part (core) and an unstable outer part (shell). The thrombus shell is very dynamic, being composed of loosely connected discoid platelets. The mechanisms underlying the observed mobility of the shell and its (patho)physiological implications are unclear. To investigate arterial thrombus mechanics, we developed a novel, to our knowledge, two-dimensional particle-based computational model of microvessel thrombosis. The model considers two types of interplatelet interactions: primary reversible (glycoprotein Ib (GPIb)-mediated) and stronger integrin-mediated interaction, which intensifies with platelet activation. At high shear rates, the former interaction leads to adhesion, and the latter is primarily responsible for stable platelet aggregation. Using a stochastic model of GPIb-mediated interaction, we initially reproduced experimental curves that characterize individual platelet interactions with a von Willebrand factor-coated surface. The addition of the second stabilizing interaction results in thrombus formation. The comparison of thrombus dynamics with experimental data allowed us to estimate the magnitude of critical interplatelet forces in the thrombus shell and the characteristic time of platelet activation. The model predicts moderate dependence of maximal thrombus height on the injury size in the absence of thrombin activity. We demonstrate that the developed stochastic model reproduces the observed highly dynamic behavior of the thrombus shell. The presence of primary stochastic interaction between platelets leads to the properties of thrombus consistent with in vivo findings; it does not grow upstream of the injury site and covers the whole injury from the first seconds of the formation. А simplified model, in which GPIb-mediated interaction is deterministic, does not reproduce these features. Thus, the stochasticity of platelet interactions is critical for thrombus plasticity, suggesting that interaction via a small number of bonds drives the dynamics of arterial thrombus shell.
Collapse
Affiliation(s)
- Valeriia N Kaneva
- Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Sciences, Moscow, Russia
| | - Joanne L Dunster
- Institute for Cardiovascular and Metabolic Research, School of Biological Sciences, University of Reading, Whiteknights, Reading, United Kingdom
| | - Vitaly Volpert
- Institut Camille Jordan, UMR 5208 CNRS, University Lyon 1, Villeurbanne, France; INRIA Team Dracula, INRIA Lyon La Doua, Villeurbanne, France; Peoples Friendship University of Russia (RUDN University), Moscow, Russian Federation
| | - Fazoil Ataullahanov
- Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Sciences, Moscow, Russia; Dmitry Rogachev National Medical Research Centre of Pediatric Hematology, Oncology and Immunology, Moscow, Russia; Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia; Faculty of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudnyi, Russia
| | - Mikhail A Panteleev
- Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Sciences, Moscow, Russia; Dmitry Rogachev National Medical Research Centre of Pediatric Hematology, Oncology and Immunology, Moscow, Russia; Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia; Faculty of Biological and Medical Physics, Moscow Institute of Physics and Technology, Dolgoprudnyi, Russia
| | - Dmitry Yu Nechipurenko
- Center for Theoretical Problems of Physico-chemical Pharmacology, Russian Academy of Sciences, Moscow, Russia; Dmitry Rogachev National Medical Research Centre of Pediatric Hematology, Oncology and Immunology, Moscow, Russia; Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia.
| |
Collapse
|
35
|
Kucukal E, Man Y, Gurkan UA, Schmidt BE. Blood Flow Velocimetry in a Microchannel During Coagulation Using Particle Image Velocimetry and Wavelet-Based Optical Flow Velocimetry. J Biomech Eng 2021; 143:1105252. [PMID: 33764427 DOI: 10.1115/1.4050647] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Indexed: 01/05/2023]
Abstract
This article describes novel measurements of the velocity of whole blood flow in a microchannel during coagulation. The blood is imaged volumetrically using a simple optical setup involving a white light source and a microscope camera. The images are processed using particle image velocimetry (PIV) and wavelet-based optical flow velocimetry (wOFV), both of which use images of individual blood cells as flow tracers. Measurements of several clinically relevant parameters such as the clotting time, decay rate, and blockage ratio are computed. The high-resolution wOFV results yield highly detailed information regarding thrombus formation and corresponding flow evolution that is the first of its kind.
Collapse
Affiliation(s)
- E Kucukal
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106
| | - Y Man
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106
| | - Umut A Gurkan
- Warren E. Rupp Associate Professor Department of Mechanical and Aerospace Engineering, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106; Department of Biomedical Engineering, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106
| | - B E Schmidt
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH 44106
| |
Collapse
|
36
|
Cai S, Li H, Zheng F, Kong F, Dao M, Karniadakis GE, Suresh S. Artificial intelligence velocimetry and microaneurysm-on-a-chip for three-dimensional analysis of blood flow in physiology and disease. Proc Natl Acad Sci U S A 2021; 118:e2100697118. [PMID: 33762307 PMCID: PMC8020788 DOI: 10.1073/pnas.2100697118] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Understanding the mechanics of blood flow is necessary for developing insights into mechanisms of physiology and vascular diseases in microcirculation. Given the limitations of technologies available for assessing in vivo flow fields, in vitro methods based on traditional microfluidic platforms have been developed to mimic physiological conditions. However, existing methods lack the capability to provide accurate assessment of these flow fields, particularly in vessels with complex geometries. Conventional approaches to quantify flow fields rely either on analyzing only visual images or on enforcing underlying physics without considering visualization data, which could compromise accuracy of predictions. Here, we present artificial-intelligence velocimetry (AIV) to quantify velocity and stress fields of blood flow by integrating the imaging data with underlying physics using physics-informed neural networks. We demonstrate the capability of AIV by quantifying hemodynamics in microchannels designed to mimic saccular-shaped microaneurysms (microaneurysm-on-a-chip, or MAOAC), which signify common manifestations of diabetic retinopathy, a leading cause of vision loss from blood-vessel damage in the retina in diabetic patients. We show that AIV can, without any a priori knowledge of the inlet and outlet boundary conditions, infer the two-dimensional (2D) flow fields from a sequence of 2D images of blood flow in MAOAC, but also can infer three-dimensional (3D) flow fields using only 2D images, thanks to the encoded physics laws. AIV provides a unique paradigm that seamlessly integrates images, experimental data, and underlying physics using neural networks to automatically analyze experimental data and infer key hemodynamic indicators that assess vascular injury.
Collapse
Affiliation(s)
- Shengze Cai
- Division of Applied Mathematics, Brown University, Providence, RI 02912
| | - He Li
- Division of Applied Mathematics, Brown University, Providence, RI 02912
| | - Fuyin Zheng
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
- School of Biological Sciences, Nanyang Technological University, 639798 Singapore
| | - Fang Kong
- School of Biological Sciences, Nanyang Technological University, 639798 Singapore
| | - Ming Dao
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139;
| | - George Em Karniadakis
- Division of Applied Mathematics, Brown University, Providence, RI 02912;
- School of Engineering, Brown University, Providence, RI 02912
| | - Subra Suresh
- Nanyang Technological University, 639798 Singapore
| |
Collapse
|
37
|
Zhussupbekov M, Wu WT, Jamiolkowski MA, Massoudi M, Antaki JF. Influence of shear rate and surface chemistry on thrombus formation in micro-crevice. J Biomech 2021; 121:110397. [PMID: 33845357 DOI: 10.1016/j.jbiomech.2021.110397] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 03/03/2021] [Indexed: 02/02/2023]
Abstract
Thromboembolic complications remain a central issue in management of patients on mechanical circulatory support. Despite the best practices employed in design and manufacturing of modern ventricular assist devices, complexity and modular nature of these systems often introduces internal steps and crevices in the flow path which can serve as nidus for thrombus formation. Thrombotic potential is influenced by multiple factors including the characteristics of the flow and surface chemistry of the biomaterial. This study explored these elements in the setting of blood flow over a micro-crevice using a multi-constituent numerical model of thrombosis. The simulations reproduced the platelet deposition patterns observed experimentally and elucidated the role of flow, shear rate, and surface chemistry in shaping the deposition. The results offer insights for design and operation of blood-contacting devices.
Collapse
Affiliation(s)
- Mansur Zhussupbekov
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA
| | - Wei-Tao Wu
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, China
| | - Megan A Jamiolkowski
- U.S. Food and Drug Administration (FDA), Center for Devices and Radiological Health (CDRH), Office of Science and Engineering Laboratories (OSEL), Silver Spring, Maryland, USA
| | - Mehrdad Massoudi
- U.S. Department of Energy, National Energy Technology Laboratory (NETL), Pittsburgh, PA, USA
| | - James F Antaki
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA.
| |
Collapse
|
38
|
Spartera M, Pessoa-Amorim G, Stracquadanio A, Von Ende A, Fletcher A, Manley P, Neubauer S, Ferreira VM, Casadei B, Hess AT, Wijesurendra RS. Left atrial 4D flow cardiovascular magnetic resonance: a reproducibility study in sinus rhythm and atrial fibrillation. J Cardiovasc Magn Reson 2021; 23:29. [PMID: 33745457 PMCID: PMC7983287 DOI: 10.1186/s12968-021-00729-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 02/03/2021] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows sophisticated quantification of left atrial (LA) blood flow, and could yield novel biomarkers of propensity for intra-cardiac thrombus formation and embolic stroke. As reproducibility is critically important to diagnostic performance, we systematically investigated technical and temporal variation of LA 4D flow in atrial fibrillation (AF) and sinus rhythm (SR). METHODS Eighty-six subjects (SR, n = 64; AF, n = 22) with wide-ranging stroke risk (CHA2DS2VASc 0-6) underwent LA 4D flow assessment of peak and mean velocity, vorticity, vortex volume, and stasis. Eighty-five (99%) underwent a second acquisition within the same session, and 74 (86%) also returned at 30 (27-35) days for an interval scan. We assessed variability attributable to manual contouring (intra- and inter-observer), and subject repositioning and reacquisition of data, both within the same session (same-day scan-rescan), and over time (interval scan). Within-subject coefficients of variation (CV) and bootstrapped 95% CIs were calculated and compared. RESULTS Same-day scan-rescan CVs were 6% for peak velocity, 5% for mean velocity, 7% for vorticity, 9% for vortex volume, and 10% for stasis, and were similar between SR and AF subjects (all p > 0.05). Interval-scan variability was similar to same-day scan-rescan variability for peak velocity, vorticity, and vortex volume (all p > 0.05), and higher for stasis and mean velocity (interval scan CVs of 14% and 8%, respectively, both p < 0.05). Longitudinal changes in heart rate and blood pressure at the interval scan in the same subjects were associated with significantly higher variability for LA stasis (p = 0.024), but not for the remaining flow parameters (all p > 0.05). SR subjects showed significantly greater interval-scan variability than AF patients for mean velocity, vortex volume, and stasis (all p < 0.05), but not peak velocity or vorticity (both p > 0.05). CONCLUSIONS LA peak velocity and vorticity are the most reproducible and temporally stable novel LA 4D flow biomarkers, and are robust to changes in heart rate, blood pressure, and differences in heart rhythm.
Collapse
Affiliation(s)
- Marco Spartera
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK.
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Oxford, UK.
| | - Guilherme Pessoa-Amorim
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Oxford, UK
| | - Antonio Stracquadanio
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Oxford, UK
| | - Adam Von Ende
- Department of Population Health, CTSU Nuffield University of Oxford, Oxford, UK
| | - Alison Fletcher
- The University of Oxford Acute Vascular Imaging Centre (AVIC), Oxford, UK
| | - Peter Manley
- The University of Oxford Acute Vascular Imaging Centre (AVIC), Oxford, UK
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Oxford, UK
| | - Vanessa M Ferreira
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Oxford, UK
| | - Barbara Casadei
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK
| | - Aaron T Hess
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Oxford, UK
| | - Rohan S Wijesurendra
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, John Radcliffe Hospital, University of Oxford, West Wing, Headley Way, Oxford, UK
- The University of Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Oxford, UK
| |
Collapse
|
39
|
Liu ZL, Ku DN, Aidun CK. Mechanobiology of shear-induced platelet aggregation leading to occlusive arterial thrombosis: A multiscale in silico analysis. J Biomech 2021; 120:110349. [PMID: 33711601 DOI: 10.1016/j.jbiomech.2021.110349] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/22/2021] [Indexed: 12/13/2022]
Abstract
Occlusive thrombosis in arteries causes heart attacks and strokes. The rapid growth of thrombus at elevated shear rates (~10,000 1/s) relies on shear-induced platelet aggregation (SIPA) thought to come about from the entanglement of von Willebrand factor (VWF) molecules. The mechanism for SIPA is not yet understood in terms of cell- and molecule-level dynamics in fast flowing bloodstreams. Towards this end, we develop a multiscale computational model to recreate SIPA in silico, where the suspension dynamics and interactions of individual platelets and VWF multimers are resolved directly. The platelet-VWF interaction via GP1b-A1 bonds is prescribed with intrinsic binding rates theoretically derived and informed by single-molecule measurements. The model is validated against existing microfluidic SIPA experiments, showing good agreement with the in vitro observations in terms of the morphology, traveling distance and capture time of the platelet aggregates. Particularly, the capture of aggregates can occur in a few milliseconds, comparable to the platelet transit time through pathologic arterial stenotic sections and much shorter than the time for shear-induced platelet activation. The multiscale SIPA simulator provides a cross-scale tool for exploring the biophysical mechanisms of SIPA in silico that are difficult to access with single-molecule measurements or micro-/macro-fluidic assays only.
Collapse
Affiliation(s)
- Zixiang L Liu
- George W. Woodruff School of Mechanical Engineering, and Parker H. Petit Institute for Bioengineering and Biosciences, Georgia Institute of Technology, GE 30332, United States.
| | - David N Ku
- George W. Woodruff School of Mechanical Engineering, and Parker H. Petit Institute for Bioengineering and Biosciences, Georgia Institute of Technology, GE 30332, United States.
| | - Cyrus K Aidun
- George W. Woodruff School of Mechanical Engineering, and Parker H. Petit Institute for Bioengineering and Biosciences, Georgia Institute of Technology, GE 30332, United States.
| |
Collapse
|
40
|
Yin M, Zheng X, Humphrey JD, Em Karniadakis G. Non-invasive Inference of Thrombus Material Properties with Physics-Informed Neural Networks. COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING 2021; 375:113603. [PMID: 33414569 PMCID: PMC7785048 DOI: 10.1016/j.cma.2020.113603] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
We employ physics-informed neural networks (PINNs) to infer properties of biological materials using synthetic data. In particular, we successfully apply PINNs on inferring permeability and viscoelastic modulus from thrombus deformation data, which can be described by the fourth-order Cahn-Hilliard and Navier-Stokes Equations. In PINNs, the partial differential equations are encoded into a loss function, where partial derivatives can be obtained through automatic differentiation (AD). In addition to tackling the challenge of calculating the fourth-order derivative in the Cahn-Hilliard equation with AD, we introduce an auxiliary network along with the main neural network to approximate the second-derivative of the energy potential term. Our model can simultaneously predict unknown material parameters and velocity, pressure, and deformation gradient fields by merely training with partial information among all data, i.e., phase field and pressure measurements, while remaining highly flexible in sampling within the spatio-temporal domain for data acquisition. We validate our model by numerical solutions from the spectral/hp element method (SEM) and demonstrate its robustness by training it with noisy measurements. Our results show that PINNs can infer the material properties from noisy synthetic data, and thus they have great potential for inferring these properties from experimental multi-modality and multi-fidelity data.
Collapse
Affiliation(s)
- Minglang Yin
- Center for Biomedical Engineering, Brown University, Providence, RI 02912
- School of Engineering, Brown University, Providence, RI 02912
| | - Xiaoning Zheng
- Division of Applied Mathematics, Brown University, Providence, RI 02912
| | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT 06520
| | - George Em Karniadakis
- Division of Applied Mathematics, Brown University, Providence, RI 02912
- Corresponding author:
| |
Collapse
|
41
|
Yazdani A, Deng Y, Li H, Javadi E, Li Z, Jamali S, Lin C, Humphrey JD, Mantzoros CS, Em Karniadakis G. Integrating blood cell mechanics, platelet adhesive dynamics and coagulation cascade for modelling thrombus formation in normal and diabetic blood. J R Soc Interface 2021; 18:20200834. [PMID: 33530862 PMCID: PMC8086870 DOI: 10.1098/rsif.2020.0834] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 01/12/2021] [Indexed: 11/12/2022] Open
Abstract
Normal haemostasis is an important physiological mechanism that prevents excessive bleeding during trauma, whereas the pathological thrombosis especially in diabetics leads to increased incidence of heart attacks and strokes as well as peripheral vascular events. In this work, we propose a new multiscale framework that integrates seamlessly four key components of blood clotting, namely transport of coagulation factors, coagulation kinetics, blood cell mechanics and platelet adhesive dynamics, to model the development of thrombi under physiological and pathological conditions. We implement this framework to simulate platelet adhesion due to the exposure of tissue factor in a three-dimensional microchannel. Our results show that our model can simulate thrombin-mediated platelet activation in the flowing blood, resulting in platelet adhesion to the injury site of the channel wall. Furthermore, we simulate platelet adhesion in diabetic blood, and our results show that both the pathological alterations in the biomechanics of blood cells and changes in the amount of coagulation factors contribute to the excessive platelet adhesion and aggregation in diabetic blood. Taken together, this new framework can be used to probe synergistic mechanisms of thrombus formation under physiological and pathological conditions, and open new directions in modelling complex biological problems that involve several multiscale processes.
Collapse
Affiliation(s)
- Alireza Yazdani
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
| | - Yixiang Deng
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
- School of Engineering, Brown University, Providence, RI 02912, USA
| | - He Li
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
| | - Elahe Javadi
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA 02115, USA
| | - Zhen Li
- Department of Mechanical Engineering, Clemson University, Clemson, SC 29634, USA
| | - Safa Jamali
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA 02115, USA
| | - Chensen Lin
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
| | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA
| | - Christos S. Mantzoros
- Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA 02215, USA
| | | |
Collapse
|
42
|
Teeraratkul C, Irwin Z, Shadden SC, Mukherjee D. Computational investigation of blood flow and flow-mediated transport in arterial thrombus neighborhood. Biomech Model Mechanobiol 2021; 20:701-715. [PMID: 33438148 DOI: 10.1007/s10237-020-01411-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 12/09/2020] [Indexed: 12/19/2022]
Abstract
A pathologically formed blood clot or thrombus is central to major cardiovascular diseases like heart attack and stroke. Detailed quantitative evaluation of flow and flow-mediated transport processes in the thrombus neighborhood within large artery hemodynamics is crucial for understanding disease progression and assessing treatment efficacy. This, however, remains a challenging task owing to the complexity of pulsatile viscous flow interactions with arbitrary shape and heterogeneous microstructure of realistic thrombi. Here, we address this challenge by conducting a systematic parametric simulation-based study on characterizing unsteady hemodynamics and flow-mediated transport in the neighborhood of an arterial thrombus. We use a hybrid particle-continuum-based finite element approach to handle arbitrary thrombus shape and microstructural variations. Results from a cohort of 50 different unsteady flow scenarios are presented, including unsteady vortical structures, pressure gradient across the thrombus boundary, finite time Lyapunov exponents, and dynamic coherent structures that organize advective transport. We clearly illustrate the combined influence of three key parameters-thrombus shape, microstructure, and extent of wall disease-in terms of: (a) determining hemodynamic features in the thrombus neighborhood and (b) governing the balance between advection, permeation, and diffusion to regulate transport processes in the thrombus neighborhood.
Collapse
Affiliation(s)
- Chayut Teeraratkul
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, United States of America
| | - Zachariah Irwin
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, United States of America
| | - Shawn C Shadden
- Department of Mechanical Engineering, University of California, Berkeley, United States of America
| | - Debanjan Mukherjee
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, United States of America.
| |
Collapse
|
43
|
Nechipurenko DY, Shibeko AM, Sveshnikova AN, Panteleev MA. In Silico Hemostasis Modeling and Prediction. Hamostaseologie 2020; 40:524-535. [PMID: 32916753 DOI: 10.1055/a-1213-2117] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Computational physiology, i.e., reproduction of physiological (and, by extension, pathophysiological) processes in silico, could be considered one of the major goals in computational biology. One might use computers to simulate molecular interactions, enzyme kinetics, gene expression, or whole networks of biochemical reactions, but it is (patho)physiological meaning that is usually the meaningful goal of the research even when a single enzyme is its subject. Although exponential rise in the use of computational and mathematical models in the field of hemostasis and thrombosis began in the 1980s (first for blood coagulation, then for platelet adhesion, and finally for platelet signal transduction), the majority of their successful applications are still focused on simulating the elements of the hemostatic system rather than the total (patho)physiological response in situ. Here we discuss the state of the art, the state of the progress toward the efficient "virtual thrombus formation," and what one can already get from the existing models.
Collapse
Affiliation(s)
- Dmitry Y Nechipurenko
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia.,Center for Theoretical Problems of Physicochemical Pharmacology of the Russian Academy of Sciences, Moscow, Russia.,Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia
| | - Aleksey M Shibeko
- Center for Theoretical Problems of Physicochemical Pharmacology of the Russian Academy of Sciences, Moscow, Russia.,Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia
| | - Anastasia N Sveshnikova
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia.,Center for Theoretical Problems of Physicochemical Pharmacology of the Russian Academy of Sciences, Moscow, Russia.,Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia
| | - Mikhail A Panteleev
- Faculty of Physics, Lomonosov Moscow State University, Moscow, Russia.,Center for Theoretical Problems of Physicochemical Pharmacology of the Russian Academy of Sciences, Moscow, Russia.,Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia
| |
Collapse
|
44
|
Zhang S, Zhang R, Wang Y, Onck PR, den Toonder JMJ. Controlled Multidirectional Particle Transportation by Magnetic Artificial Cilia. ACS NANO 2020; 14:10313-10323. [PMID: 32806065 PMCID: PMC7450663 DOI: 10.1021/acsnano.0c03801] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 07/31/2020] [Indexed: 05/27/2023]
Abstract
Manipulation of particles in a controllable manner is highly desirable in many applications. Inspired by biological cilia, this article experimentally and numerically demonstrates a versatile particle transportation platform consisting of arrays of magnetic artificial cilia (MAC) actuated by a rotating magnet. By performing a tilted conical motion, the MAC are capable of transporting particles on their tips, along designated directions that can be fully controlled by the externally applied magnetic field, in both liquid and air, at high resolution (particle precision), with varying speeds and for a range of particle sizes. Moreover, the underlying mechanism of the controlled particle transportation is studied in depth by combining experiments with numerical simulations. The results show that the adhesion and friction between the particle and the cilia are essential ingredients of the mechanism underlying the multidirectional transportation. This work offers an advanced solution to controllably transport particles along designated paths in any direction over a surface, which has potential applications in diverse fields including lab-on-a-chip devices, in vitro biomedical sciences, and self-cleaning and antifouling.
Collapse
Affiliation(s)
- Shuaizhong Zhang
- Department of Mechanical
Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Rongjing Zhang
- Zernike Institute for Advanced Materials, University of Groningen, 9747 AG Groningen, The Netherlands
| | - Ye Wang
- Department of Mechanical
Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Patrick R. Onck
- Zernike Institute for Advanced Materials, University of Groningen, 9747 AG Groningen, The Netherlands
| | - Jaap M. J. den Toonder
- Department of Mechanical
Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
45
|
Li H, Sampani K, Zheng X, Papageorgiou DP, Yazdani A, Bernabeu MO, Karniadakis GE, Sun JK. Predictive modelling of thrombus formation in diabetic retinal microaneurysms. ROYAL SOCIETY OPEN SCIENCE 2020; 7:201102. [PMID: 32968536 PMCID: PMC7481715 DOI: 10.1098/rsos.201102] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Accepted: 07/29/2020] [Indexed: 06/11/2023]
Abstract
Microaneurysms (MAs) are one of the earliest clinically visible signs of diabetic retinopathy (DR). Vision can be reduced at any stage of DR by MAs, which may enlarge, rupture and leak fluid into the neural retina. Recent advances in ophthalmic imaging techniques enable reconstruction of the geometries of MAs and quantification of the corresponding haemodynamic metrics, such as shear rate and wall shear stress, but there is lack of computational models that can predict thrombus formation in individual MAs. In this study, we couple a particle model to a continuum model to simulate the platelet aggregation in MAs with different shapes. Our simulation results show that under a physiologically relevant blood flow rate, thrombosis is more pronounced in saccular-shaped MAs than fusiform-shaped MAs, in agreement with recent clinical findings. Our model predictions of the size and shape of the thrombi in MAs are consistent with experimental observations, suggesting that our model is capable of predicting the formation of thrombus for newly detected MAs. This is the first quantitative study of thrombosis in MAs through simulating platelet aggregation, and our results suggest that computational models can be used to predict initiation and development of intraluminal thrombus in MAs as well as provide insights into their role in the pathophysiology of DR.
Collapse
Affiliation(s)
- He Li
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
| | - Konstantina Sampani
- Beetham Eye Institute, Joslin Diabetes Center, Boston, MA, USA
- Department of Medicine, Harvard Medical School, Boston, MA, USA
| | - Xiaoning Zheng
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
| | - Dimitrios P. Papageorgiou
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - Alireza Yazdani
- Division of Applied Mathematics, Brown University, Providence, RI 02912, USA
| | - Miguel O. Bernabeu
- Centre for Medical Informatics, Usher Institute, University of Edinburgh, Edinburgh, UK
| | | | - Jennifer K. Sun
- Beetham Eye Institute, Joslin Diabetes Center, Boston, MA, USA
- Department of Ophthalmology, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
46
|
Modeling Clot Formation of Shear-Injured Platelets in Flow by a Dissipative Particle Dynamics Method. Bull Math Biol 2020; 82:83. [DOI: 10.1007/s11538-020-00760-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 06/04/2020] [Indexed: 01/08/2023]
|
47
|
Pushin DM, Salikhova TY, Zlobina KE, Guria GT. Platelet activation via dynamic conformational changes of von Willebrand factor under shear. PLoS One 2020; 15:e0234501. [PMID: 32525962 PMCID: PMC7289367 DOI: 10.1371/journal.pone.0234501] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Accepted: 05/26/2020] [Indexed: 01/10/2023] Open
Abstract
Shear-induced conformational changes of von Willebrand factor (VWF) play an important role in platelet activation. A novel approach describing VWF unfolding on the platelet surface under dynamic shear stress is proposed. Cumulative effect of dynamic shear on platelet activation via conformational changes of VWF is analysed. The critical condition of shear-induced platelet activation is formulated. The explicit expression for the threshold value of cumulative shear stress as a function of VWF multimer size is derived. The results open novel prospects for pharmacological regulation of shear-induced platelet activation through control of VWF multimers size distribution.
Collapse
Affiliation(s)
- Denis M. Pushin
- National Research Center for Hematology, Moscow, Russia
- Moscow Institute of Physics and Technology, Dolgoprudny, Russia
| | | | | | - Georgy Th. Guria
- National Research Center for Hematology, Moscow, Russia
- Moscow Institute of Physics and Technology, Dolgoprudny, Russia
- * E-mail:
| |
Collapse
|
48
|
Zheng X, Yazdani A, Li H, Humphrey JD, Karniadakis GE. A three-dimensional phase-field model for multiscale modeling of thrombus biomechanics in blood vessels. PLoS Comput Biol 2020; 16:e1007709. [PMID: 32343724 PMCID: PMC7224566 DOI: 10.1371/journal.pcbi.1007709] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 05/14/2020] [Accepted: 02/03/2020] [Indexed: 01/10/2023] Open
Abstract
Mechanical interactions between flowing and coagulated blood (thrombus) are crucial in dictating the deformation and remodeling of a thrombus after its formation in hemostasis. We propose a fully-Eulerian, three-dimensional, phase-field model of thrombus that is calibrated with existing in vitro experimental data. This phase-field model considers spatial variations in permeability and material properties within a single unified mathematical framework derived from an energy perspective, thereby allowing us to study effects of thrombus microstructure and properties on its deformation and possible release of emboli under different hemodynamic conditions. Moreover, we combine this proposed thrombus model with a particle-based model which simulates the initiation of the thrombus. The volume fraction of a thrombus obtained from the particle simulation is mapped to an input variable in the proposed phase-field thrombus model. The present work is thus the first computational study to integrate the initiation of a thrombus through platelet aggregation with its subsequent viscoelastic responses to various shear flows. This framework can be informed by clinical data and potentially be used to predict the risk of diverse thromboembolic events under physiological and pathological conditions.
Collapse
Affiliation(s)
- Xiaoning Zheng
- Division of Applied Mathematics, Brown University, Providence, Rhode Island, United States of America
| | - Alireza Yazdani
- Division of Applied Mathematics, Brown University, Providence, Rhode Island, United States of America
| | - He Li
- Division of Applied Mathematics, Brown University, Providence, Rhode Island, United States of America
| | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, United States of America
| | - George E. Karniadakis
- Division of Applied Mathematics, Brown University, Providence, Rhode Island, United States of America
- * E-mail:
| |
Collapse
|
49
|
Yi Y, Tamagawa M. Development of a novel hybrid method combining finite difference method and dissipative particle dynamics to simulate thrombus formation on orifice flow. Comput Methods Biomech Biomed Engin 2020; 23:611-626. [PMID: 32310682 DOI: 10.1080/10255842.2020.1755274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
In our previous works, the transport of activated platelets (APs) on orifice flow has been simulated by finite difference method (FDM). And the distribution of AP concentration on the flow was obtained. However, the effect of platelet aggregation on the distribution of AP concentration can't be investigated by FDM because FDM can't simulate platelet aggregation. On the other hand, platelet aggregation has been simulated by dissipative particle dynamics (DPD). In this paper, a hybrid method combining FDM and DPD is proposed to investigate the effect of platelet aggregation on the distribution of AP concentration. And the hybrid method is used to simulate thrombus formation on orifice flow. As for the effect of platelet aggregation, it is found that the distribution of AP concentration in the hybrid method is different from the distribution in FDM at the places of platelet aggregation. It is considered that the difference is induced by platelet aggregation. As for the distribution of thrombus, higher AP concentration and more aggregated APs are found around the reattachment point and in the recirculation area. It is considered that thrombus is mainly distributed at these places in the simulation. And according to our previous experimental results, thrombus is mainly distributed around the reattachment point and in the recirculation area. It is concluded that the effect of platelet aggregation on the distribution of AP concentration can be investigated by the hybrid method, and the computational results agree with our previous experimental results.
Collapse
Affiliation(s)
- Y Yi
- Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Kitakyushu, Japan
| | - M Tamagawa
- Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Kitakyushu, Japan
| |
Collapse
|
50
|
Labarrere CA, Dabiri AE, Kassab GS. Thrombogenic and Inflammatory Reactions to Biomaterials in Medical Devices. Front Bioeng Biotechnol 2020; 8:123. [PMID: 32226783 PMCID: PMC7080654 DOI: 10.3389/fbioe.2020.00123] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Accepted: 02/10/2020] [Indexed: 12/17/2022] Open
Abstract
Blood-contacting medical devices of different biomaterials are often used to treat various cardiovascular diseases. Thrombus formation is a common cause of failure of cardiovascular devices. Currently, there are no clinically available biomaterials that can totally inhibit thrombosis under the more challenging environments (e.g., low flow in the venous system). Although some biomaterials reduce protein adsorption or cell adhesion, the issue of biomaterial associated with thrombosis and inflammation still exists. To better understand how to develop more thrombosis-resistant medical devices, it is essential to understand the biology and mechano-transduction of thrombus nucleation and progression. In this review, we will compare the mechanisms of thrombus development and progression in the arterial and venous systems. We will address various aspects of thrombosis, starting with biology of thrombosis, mathematical modeling to integrate the mechanism of thrombosis, and thrombus formation on medical devices. Prevention of these problems requires a multifaceted approach that involves more effective and safer thrombolytic agents but more importantly the development of novel thrombosis-resistant biomaterials mimicking the biological characteristics of the endothelium and extracellular matrix tissues that also ameliorate the development and the progression of chronic inflammation as part of the processes associated with the detrimental generation of late thrombosis and neo-atherosclerosis. Until such developments occur, engineers and clinicians must work together to develop devices that require minimal anticoagulants and thrombolytics to mitigate thrombosis and inflammation without causing serious bleeding side effects.
Collapse
Affiliation(s)
| | - Ali E Dabiri
- California Medical Innovations Institute, San Diego, CA, United States
| | - Ghassan S Kassab
- California Medical Innovations Institute, San Diego, CA, United States
| |
Collapse
|