1
|
Lin Q, Wu Z, Huang M, Dang Z, Tian L, Guan Y, Liu G, Lu Y, Tian Y. Detection of early pulmonary emphysema by multi-contrast x-ray Talbot-Lau interferometer. Med Phys 2024; 51:4133-4142. [PMID: 38578373 DOI: 10.1002/mp.17053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 03/14/2024] [Accepted: 03/24/2024] [Indexed: 04/06/2024] Open
Abstract
BACKGROUND Pulmonary emphysema is a part of chronic obstructive pulmonary disease, which is an irreversible chronic respiratory disease. In order to avoid further damage to lung tissue, early diagnosis and treatment of pulmonary emphysema is essential. PURPOSE Early pulmonary emphysema diagnosis is difficult with conventional radiographic imaging. Recently, x-ray phase contrast imaging has proved to be an effective and promising imaging strategy for soft tissue, due to its high sensitivity and multi-contrast. The aim of this study is to diagnose pulmonary emphysema early utilizing an x-ray Talbot-Lau interferometer (TLI). METHODS We successfully established the mouse model of emphysema by porcine pancreatic elastase treatment, and then used the established x-ray TLI to perform imaging experiments on the mice with different treatment time. The traditional absorption CT and phase contrast CT were obtained simultaneously through TLI. The CT results and histopathology of mice lung in different treatment time were quantitatively analyzed. RESULTS By imaging mice lungs, it can be found that phase contrast has higher sensitivity than absorption contrast in early pulmonary emphysema. The results show that the phase contrast signal could distinguish the pulmonary emphysema earlier than the conventional attenuation signal, which can be consistent with histological images. Through the quantitative analysis of pathological section and phase contrast CT, it can be found that there is a strong linear correlation. CONCLUSIONS In this study, we quantitatively analyze mean linear intercept of histological sections and CT values of mice. The results show that the phase contrast signal has higher imaging sensitivity than the attenuation signal. X-ray TLI multi-contrast imaging is proved as a potential diagnostic method for early pulmonary emphysema in mice.
Collapse
Affiliation(s)
- Qisi Lin
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
| | - Zhao Wu
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
| | - Meng Huang
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
- Ultrasonic Department, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Zheng Dang
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
| | - Lijiao Tian
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
| | - Yong Guan
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
| | - Gang Liu
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
| | - Yalin Lu
- Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, China
| | - Yangchao Tian
- National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
| |
Collapse
|
2
|
Zou X, Ren Y, Yang H, Zou M, Meng P, Zhang L, Gong M, Ding W, Han L, Zhang T. Screening and staging of chronic obstructive pulmonary disease with deep learning based on chest X-ray images and clinical parameters. BMC Pulm Med 2024; 24:153. [PMID: 38532368 DOI: 10.1186/s12890-024-02945-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 03/01/2024] [Indexed: 03/28/2024] Open
Abstract
BACKGROUND Chronic obstructive pulmonary disease (COPD) is underdiagnosed with the current gold standard measure pulmonary function test (PFT). A more sensitive and simple option for early detection and severity evaluation of COPD could benefit practitioners and patients. METHODS In this multicenter retrospective study, frontal chest X-ray (CXR) images and related clinical information of 1055 participants were collected and processed. Different deep learning algorithms and transfer learning models were trained to classify COPD based on clinical data and CXR images from 666 subjects, and validated in internal test set based on 284 participants. External test including 105 participants was also performed to verify the generalization ability of the learning algorithms in diagnosing COPD. Meanwhile, the model was further used to evaluate disease severity of COPD by predicting different grads. RESULTS The Ensemble model showed an AUC of 0.969 in distinguishing COPD by simultaneously extracting fusion features of clinical parameters and CXR images in internal test, better than models that used clinical parameters (AUC = 0.963) or images (AUC = 0.946) only. For the external test set, the AUC slightly declined to 0.934 in predicting COPD based on clinical parameters and CXR images. When applying the Ensemble model to determine disease severity of COPD, the AUC reached 0.894 for three-classification and 0.852 for five-classification respectively. CONCLUSION The present study used DL algorithms to screen COPD and predict disease severity based on CXR imaging and clinical parameters. The models showed good performance and the approach might be an effective case-finding tool with low radiation dose for COPD diagnosis and staging.
Collapse
Affiliation(s)
- XiaoLing Zou
- Department of Pulmonary and Critical Care Medicine, The Third Affiliated Hospital of Sun Yat-sen University, Institute of Respiratory Diseases of Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - Yong Ren
- Scientific research project department, Guangdong Artificial Intelligence and Digital Economy Laboratory (Guangzhou), Pazhou Lab, Guangzhou, China
- Shensi lab, Shenzhen Institute for Advanced Study, UESTC, Shenzhen, China
| | - HaiLing Yang
- Department of Pulmonary and Critical Care Medicine, The Third Affiliated Hospital of Sun Yat-sen University, Institute of Respiratory Diseases of Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - ManMan Zou
- Department of Pulmonary and Critical Care Medicine, Dongguan People's Hospital, Dongguan, China
| | - Ping Meng
- Department of Pulmonary and Critical Care Medicine, the Six Affiliated Hospital of Guangzhou Medical University, Qingyuan People's Hospital, Qingyuan, China
| | - LiYi Zhang
- Department of Pulmonary and Critical Care Medicine, The Third Affiliated Hospital of Sun Yat-sen University, Institute of Respiratory Diseases of Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - MingJuan Gong
- Department of Internal Medicine, Huazhou Hospital of Traditional Chinese Medicine, Huazhou, China
| | - WenWen Ding
- Department of Pulmonary and Critical Care Medicine, The Third Affiliated Hospital of Sun Yat-sen University, Institute of Respiratory Diseases of Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China
| | - LanQing Han
- Center for artificial intelligence in medicine, Research Institute of Tsinghua, Pearl River Delta, Guangzhou, China.
| | - TianTuo Zhang
- Department of Pulmonary and Critical Care Medicine, The Third Affiliated Hospital of Sun Yat-sen University, Institute of Respiratory Diseases of Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, 510630, China.
| |
Collapse
|
3
|
Alloo SJ, Morgan KS, Paganin DM, Pavlov KM. Multimodal intrinsic speckle-tracking (MIST) to extract images of rapidly-varying diffuse X-ray dark-field. Sci Rep 2023; 13:5424. [PMID: 37012270 PMCID: PMC10070351 DOI: 10.1038/s41598-023-31574-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 03/14/2023] [Indexed: 04/05/2023] Open
Abstract
Speckle-based phase-contrast X-ray imaging (SB-PCXI) can reconstruct high-resolution images of weakly-attenuating materials that would otherwise be indistinguishable in conventional attenuation-based X-ray imaging. The experimental setup of SB-PCXI requires only a sufficiently coherent X-ray source and spatially random mask, positioned between the source and detector. The technique can extract sample information at length scales smaller than the imaging system's spatial resolution; this enables multimodal signal reconstruction. "Multimodal Intrinsic Speckle-Tracking" (MIST) is a rapid and deterministic formalism derived from the paraxial-optics form of the Fokker-Planck equation. MIST simultaneously extracts attenuation, refraction, and small-angle scattering (diffusive dark-field) signals from a sample and is more computationally efficient compared to alternative speckle-tracking approaches. Hitherto, variants of MIST have assumed the diffusive dark-field signal to be spatially slowly varying. Although successful, these approaches have been unable to well-describe unresolved sample microstructure whose statistical form is not spatially slowly varying. Here, we extend the MIST formalism such that this restriction is removed, in terms of a sample's rotationally-isotropic diffusive dark-field signal. We reconstruct multimodal signals of two samples, each with distinct X-ray attenuation and scattering properties. The reconstructed diffusive dark-field signals have superior image quality-as measured by the naturalness image quality evaluator, signal-to-noise ratio, and azimuthally averaged power-spectrum-compared to our previous approaches which assume the diffusive dark-field to be a slowly varying function of transverse position. Our generalisation may assist increased adoption of SB-PCXI in applications such as engineering and biomedical disciplines, forestry, and palaeontology, and is anticipated to aid the development of speckle-based diffusive dark-field tensor tomography.
Collapse
Affiliation(s)
- Samantha J Alloo
- School of Physical and Chemical Sciences, University of Canterbury, Christchurch, New Zealand.
| | - Kaye S Morgan
- School of Physics and Astronomy, Monash University, Clayton, VIC, Australia
| | - David M Paganin
- School of Physics and Astronomy, Monash University, Clayton, VIC, Australia
| | - Konstantin M Pavlov
- School of Physical and Chemical Sciences, University of Canterbury, Christchurch, New Zealand
- School of Physics and Astronomy, Monash University, Clayton, VIC, Australia
- School of Science and Technology, University of New England, Armidale, NSW, Australia
| |
Collapse
|
4
|
Dark-field chest X-ray imaging for the assessment of COVID-19-pneumonia. COMMUNICATIONS MEDICINE 2022; 2:147. [PMID: 36411311 PMCID: PMC9678896 DOI: 10.1038/s43856-022-00215-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 11/09/2022] [Indexed: 11/22/2022] Open
Abstract
Background Currently, alternative medical imaging methods for the assessment of pulmonary involvement in patients infected with COVID-19 are sought that combine a higher sensitivity than conventional (attenuation-based) chest radiography with a lower radiation dose than CT imaging. Methods Sixty patients with COVID-19-associated lung changes in a CT scan and 40 subjects without pathologic lung changes visible in the CT scan were included (in total, 100, 59 male, mean age 58 ± 14 years). All patients gave written informed consent. We employed a clinical setup for grating-based dark-field chest radiography, obtaining both a dark-field and a conventional attenuation image in one image acquisition. Attenuation images alone, dark-field images alone, and both displayed simultaneously were assessed for the presence of COVID-19-associated lung changes on a scale from 1 to 6 (1 = surely not, 6 = surely) by four blinded radiologists. Statistical analysis was performed by evaluation of the area under the receiver–operator-characteristics curves (AUC) using Obuchowski’s method with a 0.05 level of significance. Results We show that dark-field imaging has a higher sensitivity for COVID-19-pneumonia than attenuation-based imaging and that the combination of both is superior to one imaging modality alone. Furthermore, a quantitative image analysis shows a significant reduction of dark-field signals for COVID-19-patients. Conclusions Dark-field imaging complements and improves conventional radiography for the visualisation and detection of COVID-19-pneumonia. Computed tomography (CT) imaging uses X-rays to obtain images of the inside of the body. It is used to look at lung damage in patients with COVID-19. However, CT imaging exposes the patient to a considerable amount of radiation. As radiation exposure can lead to the development of cancer, exposure should be minimised. Conventional plain X-ray imaging uses lower amounts of radiation but lacks sensitivity. We used dark-field chest X-ray imaging, which also uses low amounts of radiation, to assess the lungs of patients with COVID-19. Radiologists identified pneumonia in patients more easily from dark-field images than from usual plain X-ray images. We anticipate dark-field X-ray imaging will be useful to follow-up patients suspected of having lung damage. Frank, Gassert et al. use dark-field chest X-ray imaging to assess COVID-19-pneumonia. Dark-field imaging has a higher sensitivity for COVID-19-pneumonia than attenuation-based imaging and provides an ultralow dose alternative to computed tomography imaging for that purpose.
Collapse
|
5
|
Dark-field chest x-ray imaging: first experience in patients with alpha1-antitrypsin deficiency. Eur Radiol Exp 2022; 6:9. [PMID: 35229244 PMCID: PMC8885951 DOI: 10.1186/s41747-022-00263-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 01/04/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Spirometry and conventional chest x-ray have limitations in investigating early emphysema, while computed tomography, the reference imaging method in this context, is not part of routine patient care due to its higher radiation dose. In this work, we investigated a novel low-dose imaging modality, dark-field chest x-ray, for the evaluation of emphysema in patients with alpha1-antitrypsin deficiency.
Methods
By exploiting wave properties of x-rays for contrast formation, dark-field chest x-ray visualises the structural integrity of the alveoli, represented by a high signal over the lungs in the dark-field image. We investigated four patients with alpha1-antitrypsin deficiency with a novel dark-field x-ray prototype and simultaneous conventional chest x-ray. The extent of pulmonary function impairment was assessed by pulmonary function measurement and regional emphysema distribution was compared with CT in one patient.
Results
We show that dark-field chest x-ray visualises the extent of pulmonary emphysema displaying severity and regional differences. Areas with low dark-field signal correlate with emphysematous changes detected by computed tomography using a threshold of -950 Hounsfield units. The airway parameters obtained by whole-body plethysmography and single breath diffusing capacity of the lungs for carbon monoxide demonstrated typical changes of advanced emphysema.
Conclusions
Dark-field chest x-ray directly visualised the severity and regional distribution of pulmonary emphysema compared to conventional chest x-ray in patients with alpha1-antitrypsin deficiency. Due to the ultra-low radiation dose in comparison to computed tomography, dark-field chest x-ray could be beneficial for long-term follow-up in these patients.
Collapse
|
6
|
A Laser Frequency Transverse Modulation Might Compensate for the Spectral Broadening Due to Large Electron Energy Spread in Thomson Sources. PHOTONICS 2022. [DOI: 10.3390/photonics9020062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Compact laser plasma accelerators generate high-energy electron beams with increasing quality. When used in inverse Compton backscattering, however, the relatively large electron energy spread jeopardizes potential applications requiring small bandwidths. We present here a novel interaction scheme that allows us to compensate for the negative effects of the electron energy spread on the spectrum, by introducing a transverse spatial frequency modulation in the laser pulse. Such a laser chirp, together with a properly dispersed electron beam, can substantially reduce the broadening of the Compton bandwidth due to the electron energy spread. We show theoretical analysis and numerical simulations for hard X-ray Thomson sources based on laser plasma accelerators.
Collapse
|
7
|
Burkhardt R, Gora T, Fingerle AA, Sauter AP, Meurer F, Gassert FT, Dobiasch S, Schilling D, Feuchtinger A, Walch AK, Multhoff G, Herzen J, Noël PB, Rummeny EJ, Combs SE, Schmid TE, Pfeiffer F, Wilkens JJ. In-vivo X-ray dark-field computed tomography for the detection of radiation-induced lung damage in mice. Phys Imaging Radiat Oncol 2021; 20:11-16. [PMID: 34611553 PMCID: PMC8476771 DOI: 10.1016/j.phro.2021.09.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 09/13/2021] [Accepted: 09/13/2021] [Indexed: 11/22/2022] Open
Abstract
Radiation-induced lung damage was observed using X-ray dark-field tomography. In this pre-clinical study, mouse lungs were irradiated and subsequently imaged. We report increased sensitivity of X-ray dark-field tomography over absorption-based tomography.
Background and Purpose Radiotherapy of thoracic tumours can lead to side effects in the lung, which may benefit from early diagnosis. We investigated the potential of X-ray dark-field computed tomography by a proof-of-principle murine study in a clinically relevant radiotherapeutic setting aiming at the detection of radiation-induced lung damage. Material and Methods Six mice were irradiated with 20 Gy to the entire right lung. Together with five unirradiated control mice, they were imaged using computed tomography with absorption and dark-field contrast before and 16 weeks post irradiation. Mean pixel values for the right and left lung were calculated for both contrasts, and the right-to-left-ratio R of these means was compared. Radiologists also assessed the tomograms acquired 16 weeks post irradiation. Sensitivity, specificity, inter- and intra-reader accuracy were evaluated. Results In absorption contrast the group-average of R showed no increase in the control group and increased by 7% (p = 0.005) in the irradiated group. In dark-field contrast, it increased by 2% in the control group and by 14% (p = 0.005) in the irradiated group. Specificity was 100% for both contrasts but sensitivity was almost four times higher using dark-field tomography. Two cases were missed by absorption tomography but were detected by dark-field tomography. Conclusions The applicability of X-ray dark-field computed tomography for the detection of radiation-induced lung damage was demonstrated in a pre-clinical mouse model. The presented results illustrate the differences between dark-field and absorption contrast and show that dark-field tomography could be advantageous in future clinical settings.
Collapse
Affiliation(s)
- Rico Burkhardt
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany.,Physics Department, Technical University of Munich, Garching, Germany
| | - Thomas Gora
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Alexander A Fingerle
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Andreas P Sauter
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Felix Meurer
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Florian T Gassert
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Sophie Dobiasch
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany
| | - Daniela Schilling
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany
| | - Annette Feuchtinger
- Abteilung Analytische Pathologie, Helmholtz Zentrum München, Neuherberg, Germany
| | - Axel K Walch
- Abteilung Analytische Pathologie, Helmholtz Zentrum München, Neuherberg, Germany
| | - Gabriele Multhoff
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany.,TranslaTUM, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Julia Herzen
- Physics Department, Technical University of Munich, Garching, Germany.,Chair of Biomedical Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering (MSB), Technical University of Munich, Garching, Germany
| | - Peter B Noël
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Ernst J Rummeny
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Stephanie E Combs
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany.,Deutsches Konsortium für Translationale Krebsforschung (DKTK), Partner Site Munich, Munich, Germany
| | - Thomas E Schmid
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany
| | - Franz Pfeiffer
- Physics Department, Technical University of Munich, Garching, Germany.,Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Chair of Biomedical Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering (MSB), Technical University of Munich, Garching, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Physics Department, Technical University of Munich, Garching, Germany.,Chair of Biomedical Physics, Technical University of Munich, Garching, Germany
| |
Collapse
|
8
|
Pyakurel U, Sun W, Cheung P, D'Moore D, Zhang X, MacDonald CA, Petruccelli JC. Phase and dark-field imaging with mesh-based structured illumination and polycapillary optics. Med Phys 2021; 48:6642-6657. [PMID: 34554583 DOI: 10.1002/mp.15247] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 08/23/2021] [Accepted: 09/07/2021] [Indexed: 12/30/2022] Open
Abstract
PURPOSE X-ray phase and dark-field (DF) imaging have been shown to improve the diagnostic capabilities of X-ray systems. However, these methods have found limited clinical use due to the need for multiple precision gratings with limited field of view or requirements on X-ray coherence that may not be easily translated to clinical practice. This work aims to develop a practicable X-ray phase and DF imaging system that could be translated and practiced in the clinic. METHODS This work employs a conventional source to create structured illumination with a simple wire mesh. A mesh-shifting algorithm is used to allow wider Fourier windowing to enhance resolution. Deconvolution of the source spot width and camera resolution improves accuracy. Polycapillary optics are employed to enhance coherence. The effects of incorporating optics with two different focal lengths are compared. Information apparent in enhanced absorption images, phase images, and DF images of fat embedded phantoms were compared and subjected to a limited receiver operator characteristic (ROC) study. The DF images of the moist and dry porous object (sponges) were compared. RESULTS The mesh-based phase and DF imaging system constructs images with three different information types: scatter-free absorption images, differential phase images, and scatter magnitude/DF images, simultaneously from the same original image. The polycapillary optic enhances the coherence of the beam. The deblurring technique corrects the phase signal error due to geometrical blur and the limitation of the camera modulation transfer function (MTF) and removes image artifacts to improve the resolution in a single shot. The mesh-shifting method allows the use of a wider Fourier processing window, which gives even higher resolution, at the expense of an increased dose. The limited ROC study confirms the efficacy of the system over the conventional system. DF images of moist and dry porous object show the significance of the system in the imaging of lung infections. CONCLUSION The mesh-based X-ray phase and DF imaging system is an inexpensive and easy setup in terms of alignment and data acquisition and can produce phase and DF images in a single shot with wide field of view. The system shows significant potential for use in diagnostic imaging in a clinical setting.
Collapse
Affiliation(s)
- Uttam Pyakurel
- Department of Physics, University at Albany, Albany, New York, USA
| | - Weiyuan Sun
- Department of Physics, University at Albany, Albany, New York, USA
| | - Pikting Cheung
- Department of Physics, University at Albany, Albany, New York, USA
| | - Desirée D'Moore
- Department of Physics, University at Albany, Albany, New York, USA
| | - Xiaoyun Zhang
- Department of Physics, University at Albany, Albany, New York, USA.,Nuclear Science and Technology, Beijing Normal University, Beijing, China
| | | | | |
Collapse
|
9
|
Meyer S, Shi SZ, Shapira N, Maidment ADA, Noël PB. Quantitative analysis of speckle-based X-ray dark-field imaging using numerical wave-optics simulations. Sci Rep 2021; 11:16113. [PMID: 34373478 PMCID: PMC8352882 DOI: 10.1038/s41598-021-95227-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 07/12/2021] [Indexed: 11/24/2022] Open
Abstract
The dark-field signal measures the small-angle scattering strength and provides complementary diagnostic information. This is of particular interest for lung imaging due to the pronounced small-angle scatter from the alveolar microstructure. However, most dark-field imaging techniques are relatively complex, dose-inefficient, and require sophisticated optics and highly coherent X-ray sources. Speckle-based imaging promises to overcome these limitations due to its simple and versatile setup, only requiring the addition of a random phase modulator to conventional X-ray equipment. We investigated quantitatively the influence of sample structure, setup geometry, and source energy on the dark-field signal in speckle-based X-ray imaging with wave-optics simulations for ensembles of micro-spheres. We show that the dark-field signal is accurately predicted via a model originally derived for grating interferometry when using the mean frequency of the speckle pattern power spectral density as the characteristic speckle size. The size directly reflects the correlation length of the diffuser surface and did not change with energy or propagation distance within the near-field. The dark-field signal had a distinct dependence on sample structure and setup geometry but was also affected by beam hardening-induced modifications of the visibility spectrum. This study quantitatively demonstrates the behavior of the dark-field signal in speckle-based X-ray imaging.
Collapse
Affiliation(s)
- Sebastian Meyer
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19103, USA.
| | - Serena Z Shi
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19103, USA
| | - Nadav Shapira
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19103, USA
| | - Andrew D A Maidment
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19103, USA
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19103, USA.
- Department of Diagnostic and Interventional Radiology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, 81675, Munich, Germany.
| |
Collapse
|
10
|
Frank M, Urban T, Willer K, Noichl W, De Marco F, Schick R, Gleich B, Schegerer A, Lechel U, Meyer P, Mohr J, Koehler T, Yaroshenko A, Maack I, Pralow T, Proksa R, Renger B, Noël P, Fingerle A, Pfeiffer D, Rummeny E, Herzen J, Pfeiffer F. Dosimetry on first clinical dark-field chest radiography. Med Phys 2021; 48:6152-6159. [PMID: 34314019 DOI: 10.1002/mp.15132] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 06/02/2021] [Accepted: 06/30/2021] [Indexed: 12/20/2022] Open
Abstract
PURPOSE The purpose of this study was to evaluate the dose characteristic for patient examinations at the first clinical X-ray dark-field chest radiography system and to determine whether the effective patient dose is within a clinically acceptable dose range. METHODS A clinical setup for grating-based dark-field chest radiography was constructed and commissioned, operating at a tube voltage of 70 kVp. Thermoluminescent dosimeter (TLD) measurements were conducted using an anthropomorphic phantom modeling the reference person to obtain a conversion coefficient relating dose area product (DAP) to effective patient dose at the dark-field system. For 92 patients, the DAP values for posterior-anterior measurements were collected at the dark-field system. Using the previously determined conversion coefficient, the effective dose was calculated. RESULTS A reference person, modeled by an anthropomorphic phantom, receives an effective dose of 35 µSv. For the examined patients, a mean effective dose of 39 µSv was found. CONCLUSIONS The effective dose at the clinical dark-field radiography system, generating both attenuation and dark-field images, is within the range of reported standard dose values for chest radiography.
Collapse
Affiliation(s)
- Manuela Frank
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Theresa Urban
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Konstantin Willer
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Wolfgang Noichl
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Fabio De Marco
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Rafael Schick
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Bernhard Gleich
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Alexander Schegerer
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Ursula Lechel
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Neuherberg, Germany
| | - Pascal Meyer
- Karlsruhe Institute of Technology, Institute of Microstructure Technology, Eggenstein-Leopoldshafen, Germany
| | - Juergen Mohr
- Karlsruhe Institute of Technology, Institute of Microstructure Technology, Eggenstein-Leopoldshafen, Germany
| | | | | | - Ingo Maack
- Philips Medical Systems DMC GmbH, Hamburg, Germany
| | | | | | - Bernhard Renger
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany
| | - Peter Noël
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany
| | - Alexander Fingerle
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany
| | - Ernst Rummeny
- Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany
| | - Julia Herzen
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics, School of Natural Sciences and Munich School of BioEngineering, Technical University of Munich, Garching, Germany.,Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany
| |
Collapse
|
11
|
Andrejewski J, De Marco F, Willer K, Noichl W, Gustschin A, Koehler T, Meyer P, Kriner F, Fischer F, Braun C, Fingerle AA, Herzen J, Pfeiffer F, Pfeiffer D. Whole-body x-ray dark-field radiography of a human cadaver. Eur Radiol Exp 2021; 5:6. [PMID: 33495889 PMCID: PMC7835263 DOI: 10.1186/s41747-020-00201-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 12/03/2020] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND Grating-based x-ray dark-field and phase-contrast imaging allow extracting information about refraction and small-angle scatter, beyond conventional attenuation. A step towards clinical translation has recently been achieved, allowing further investigation on humans. METHODS After the ethics committee approval, we scanned the full body of a human cadaver in anterior-posterior orientation. Six measurements were stitched together to form the whole-body image. All radiographs were taken at a three-grating large-object x-ray dark-field scanner, each lasting about 40 s. Signal intensities of different anatomical regions were assessed. The magnitude of visibility reduction caused by beam hardening instead of small-angle scatter was analysed using different phantom materials. Maximal effective dose was 0.3 mSv for the abdomen. RESULTS Combined attenuation and dark-field radiography are technically possible throughout a whole human body. High signal levels were found in several bony structures, foreign materials, and the lung. Signal levels were 0.25 ± 0.13 (mean ± standard deviation) for the lungs, 0.08 ± 0.06 for the bones, 0.023 ± 0.019 for soft tissue, and 0.30 ± 0.02 for an antibiotic bead chain. We found that phantom materials, which do not produce small-angle scatter, can generate a strong visibility reduction signal. CONCLUSION We acquired a whole-body x-ray dark-field radiograph of a human body in few minutes with an effective dose in a clinical acceptable range. Our findings suggest that the observed visibility reduction in the bone and metal is dominated by beam hardening and that the true dark-field signal in the lung is therefore much higher than that of the bone.
Collapse
Affiliation(s)
- Jana Andrejewski
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.
| | - Fabio De Marco
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | - Konstantin Willer
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | - Wolfgang Noichl
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | - Alex Gustschin
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | | | - Pascal Meyer
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, 76344, Eggenstein-Leopoldshafen, Germany
| | - Fabian Kriner
- Institut für Rechtsmedizin, Ludwig-Maximilians-Universität München, 80336, Munich, Germany
| | - Florian Fischer
- Institut für Rechtsmedizin, Ludwig-Maximilians-Universität München, 80336, Munich, Germany
| | - Christian Braun
- Institut für Rechtsmedizin, Ludwig-Maximilians-Universität München, 80336, Munich, Germany
| | - Alexander A Fingerle
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, 81675, Munich, Germany
| | - Julia Herzen
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany.,Department of Diagnostic and Interventional Radiology, Technical University of Munich, 81675, Munich, Germany
| | - Daniela Pfeiffer
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, 81675, Munich, Germany
| |
Collapse
|
12
|
Nelson BJ, Leng S, Shanblatt ER, McCollough CH, Koenig T. Empirical beam hardening and ring artifact correction for x-ray grating interferometry (EBHC-GI). Med Phys 2021; 48:1327-1340. [PMID: 33338261 DOI: 10.1002/mp.14672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 11/03/2020] [Accepted: 12/08/2020] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Talbot-Lau grating interferometry enables the use of polychromatic x-ray sources, extending the range of potential applications amenable to phase contrast imaging. However, these sources introduce beam hardening effects not only from the samples but also from the gratings. As a result, grating inhomogeneities due to manufacturing imperfections can cause spectral nonuniformity artifacts when used with polychromatic sources. Consequently, the different energy dependencies of absorption, phase, and visibility contrasts impose challenges that so far have limited the achievable image quality. The purpose of this work was to develop and validate a correction strategy for grating-based x-ray imaging that accounts for beam hardening generated from both the imaged object and the gratings. METHODS The proposed two-variable polynomial expansion strategy was inspired by work performed to address beam hardening from a primary modulator. To account for the multicontrast nature of grating interferometry, this approach was extended to each contrast to obtain three sets of correction coefficients, which were determined empirically from a calibration scan. The method's feasibility was demonstrated using a tabletop Talbot-Lau grating interferometer micro-computed tomography (CT) system using CT acquisitions of a water sample and a silicon sample, representing low and high atomic number materials. Spectral artifacts such as cupping and ring artifacts were quantified using mean squared error (MSE) from the beam-hardening-free target image and standard deviation within a reconstructed image of the sample. Finally, the model developed using the water sample was applied to a fixated murine lung sample to demonstrate robustness for similar materials. RESULTS The water sample's absorption CT image was most impacted by spectral artifacts, but following correction to decrease ring artifacts, an 80% reduction in MSE and 57% reduction in standard deviation was observed. The silicon sample created severe artifacts in all contrasts, but following correction, MSE was reduced by 94% in absorption, 96% in phase, and 90% in visibility images. These improvements were due to the removal of ring artifacts for all contrasts and reduced cupping in absorption and phase images and reduced capping in visibility images. When the water calibration coefficients were applied to the lung sample, ring artifacts most prominent in the absorption contrast were eliminated. CONCLUSIONS The described method, which was developed to remove artifacts in absorption, phase, and normalized visibility micro-CT images due to beam hardening in the system gratings and imaged object, reduced the MSE by up to 96%. The method depends on calibrations that can be performed on any system and does not require detailed knowledge of the x-ray spectrum, detector energy response, grating attenuation properties and imperfections, or the geometry and composition of the imaged object.
Collapse
Affiliation(s)
- Brandon J Nelson
- Graduate Program in Biomedical Engineering and Physiology, Mayo Clinic Graduate School of Biomedical Sciences, Rochester, MN, 55905, USA.,Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA
| | | | | | - Thomas Koenig
- Graduate Program in Biomedical Engineering and Physiology, Mayo Clinic Graduate School of Biomedical Sciences, Rochester, MN, 55905, USA.,Ziehm Imaging, Lina-Ammon-Str. 10, Nuremberg, 90471, Germany
| |
Collapse
|
13
|
Burkhardt R, Gora T, Fingerle AA, Sauter AP, Meurer F, Umkehrer S, von Teuffenbach M, Kampfer S, Schilling D, Feuchtinger A, Walch AK, Rummeny E, Combs SE, Schmid TE, Pfeiffer F, Wilkens JJ, Herzen J. Early detection of radiation-induced lung damage with X-ray dark-field radiography in mice. Eur Radiol 2020; 31:4175-4183. [PMID: 33211140 PMCID: PMC8128748 DOI: 10.1007/s00330-020-07459-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 10/12/2020] [Accepted: 11/03/2020] [Indexed: 02/01/2023]
Abstract
OBJECTIVE Assessing the advantage of x-ray dark-field contrast over x-ray transmission contrast in radiography for the detection of developing radiation-induced lung damage in mice. METHODS Two groups of female C57BL/6 mice (irradiated and control) were imaged obtaining both contrasts monthly for 28 weeks post irradiation. Six mice received 20 Gy of irradiation to the entire right lung sparing the left lung. The control group of six mice was not irradiated. A total of 88 radiographs of both contrasts were evaluated for both groups based on average values for two regions of interest, covering (irradiated) right lung and healthy left lung. The ratio of these average values, R, was distinguished between healthy and damaged lungs for both contrasts. The time-point when deviations of R from healthy lung exceeded 3σ was determined and compared among contrasts. The Wilcoxon-Mann-Whitney test was used to test against the null hypothesis that there is no difference between both groups. A selection of 32 radiographs was assessed by radiologists. Sensitivity and specificity were determined in order to compare the diagnostic potential of both contrasts. Inter-reader and intra-reader accuracy were rated with Cohen's kappa. RESULTS Radiation-induced morphological changes of lung tissue caused deviations from the control group that were measured on average 10 weeks earlier with x-ray dark-field contrast than with x-ray transmission contrast. Sensitivity, specificity, and accuracy doubled using dark-field radiography. CONCLUSION X-ray dark-field radiography detects morphological changes of lung tissue associated with radiation-induced damage earlier than transmission radiography in a pre-clinical mouse model. KEY POINTS • Significant deviations from healthy lung due to irradiation were measured after 16 weeks with x-ray dark-field radiography (p = 0.004). • Significant deviations occur on average 10 weeks earlier for x-ray dark-field radiography in comparison to x-ray transmission radiography. • Sensitivity and specificity doubled when using x-ray dark-field radiography instead of x-ray transmission radiography.
Collapse
Affiliation(s)
- Rico Burkhardt
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany. .,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany. .,Physics Department, Technical University of Munich, Garching, Germany.
| | - Thomas Gora
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Alexander A Fingerle
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Andreas P Sauter
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Felix Meurer
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Stephan Umkehrer
- Chair of Biomedical Physics, Technical University of Munich, Garching, Germany
| | | | - Severin Kampfer
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Physics Department, Technical University of Munich, Garching, Germany
| | - Daniela Schilling
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany
| | - Annette Feuchtinger
- Abteilung Analytische Pathologie, Helmholtz Zentrum München, Neuherberg, Germany
| | - Axel K Walch
- Abteilung Analytische Pathologie, Helmholtz Zentrum München, Neuherberg, Germany
| | - Ernst Rummeny
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany
| | - Stephanie E Combs
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany.,Deutsches Konsortium für Translationale Krebsforschung (DKTK), Partner Site Munich, Munich, Germany
| | - Thomas E Schmid
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Neuherberg, Germany
| | - Franz Pfeiffer
- Department of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Chair of Biomedical Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering (MSB), Technical University of Munich, Garching, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Technical University of Munich, School of Medicine and Klinikum rechts der Isar, Munich, Germany.,Physics Department, Technical University of Munich, Garching, Germany.,Chair of Biomedical Physics, Technical University of Munich, Garching, Germany
| | - Julia Herzen
- Physics Department, Technical University of Munich, Garching, Germany.,Chair of Biomedical Physics, Technical University of Munich, Garching, Germany.,Munich School of BioEngineering (MSB), Technical University of Munich, Garching, Germany
| |
Collapse
|
14
|
Kitchen MJ, Buckley GA, Kerr LT, Lee KL, Uesugi K, Yagi N, Hooper SB. Emphysema quantified: mapping regional airway dimensions using 2D phase contrast X-ray imaging. BIOMEDICAL OPTICS EXPRESS 2020; 11:4176-4190. [PMID: 32923035 PMCID: PMC7449757 DOI: 10.1364/boe.390587] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 05/29/2020] [Accepted: 06/02/2020] [Indexed: 06/11/2023]
Abstract
We have developed an analyser-based phase contrast X-ray imaging technique to measure the mean length scale of pores or particles that cannot be resolved directly by the system. By combining attenuation, phase and ultra-small angle X-ray scattering information, the technique was capable of measuring differences in airway dimension between lungs of healthy mice and those with mild and severe emphysema. Our measurements of airway dimensions from 2D images showed a 1:1 relationship to the actual airway dimensions measured using micro-CT. Using 80 images, the sensitivity and specificity were measured to be 0.80 and 0.89, respectively, with the area under the ROC curve close to ideal at 0.96. Reducing the number of images to 11 slightly decreased the sensitivity to 0.75 and the ROC curve area to 0.90, whilst the specificity remained high at 0.89.
Collapse
Affiliation(s)
- Marcus J. Kitchen
- School of Physics and Astronomy, Monash
University, Clayton, Victoria, 3800, Australia
| | - Genevieve A. Buckley
- School of Physics and Astronomy, Monash
University, Clayton, Victoria, 3800, Australia
| | | | - Katie L. Lee
- School of Physics and Astronomy, Monash
University, Clayton, Victoria, 3800, Australia
| | - Kentaro Uesugi
- The Ritchie Centre, MIMR-PHI Institute of
Medical Research and the Department of Obstetrics and Gynaecology,
Monash University, Clayton, Victoria, 3168, Australia
| | - Naoto Yagi
- The Ritchie Centre, MIMR-PHI Institute of
Medical Research and the Department of Obstetrics and Gynaecology,
Monash University, Clayton, Victoria, 3168, Australia
| | | |
Collapse
|
15
|
Exploring potential of different X-ray imaging methods for early-stage lung cancer detection. RADIATION DETECTION TECHNOLOGY AND METHODS 2020. [DOI: 10.1007/s41605-020-00173-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
16
|
Yang L, Gradl R, Dierolf M, Möller W, Kutschke D, Feuchtinger A, Hehn L, Donnelley M, Günther B, Achterhold K, Walch A, Stoeger T, Razansky D, Pfeiffer F, Morgan KS, Schmid O. Multimodal Precision Imaging of Pulmonary Nanoparticle Delivery in Mice: Dynamics of Application, Spatial Distribution, and Dosimetry. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2019; 15:e1904112. [PMID: 31639283 DOI: 10.1002/smll.201904112] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2019] [Revised: 09/12/2019] [Indexed: 06/10/2023]
Abstract
Targeted delivery of nanomedicine/nanoparticles (NM/NPs) to the site of disease (e.g., the tumor or lung injury) is of vital importance for improved therapeutic efficacy. Multimodal imaging platforms provide powerful tools for monitoring delivery and tissue distribution of drugs and NM/NPs. This study introduces a preclinical imaging platform combining X-ray (two modes) and fluorescence imaging (three modes) techniques for time-resolved in vivo and spatially resolved ex vivo visualization of mouse lungs during pulmonary NP delivery. Liquid mixtures of iodine (contrast agent for X-ray) and/or (nano)particles (X-ray absorbing and/or fluorescent) are delivered to different regions of the lung via intratracheal instillation, nasal aspiration, and ventilator-assisted aerosol inhalation. It is demonstrated that in vivo propagation-based phase-contrast X-ray imaging elucidates the dynamic process of pulmonary NP delivery, while ex vivo fluorescence imaging (e.g., tissue-cleared light sheet fluorescence microscopy) reveals the quantitative 3D drug/particle distribution throughout the entire lung with cellular resolution. The novel and complementary information from this imaging platform unveils the dynamics and mechanisms of pulmonary NM/NP delivery and deposition for each of the delivery routes, which provides guidance on optimizing pulmonary delivery techniques and novel-designed NM for targeting and efficacy.
Collapse
Affiliation(s)
- Lin Yang
- Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, 81377, Germany
- Institute of Lung Biology and Disease, Helmholtz Zentrum München-German Research Center for Environmental Health, Neuherberg, 85764, Germany
- Faculty of Medicine, Technical University of Munich, Munich, 80333, Germany
| | - Regine Gradl
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, 85748, Germany
- Munich School of BioEngineering, Technical University of Munich, Garching, 85748, Germany
- Institute for Advanced Study, Technical University of Munich, Garching, 85748, Germany
| | - Martin Dierolf
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, 85748, Germany
- Munich School of BioEngineering, Technical University of Munich, Garching, 85748, Germany
| | - Winfried Möller
- Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, 81377, Germany
- Institute of Lung Biology and Disease, Helmholtz Zentrum München-German Research Center for Environmental Health, Neuherberg, 85764, Germany
| | - David Kutschke
- Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, 81377, Germany
- Institute of Lung Biology and Disease, Helmholtz Zentrum München-German Research Center for Environmental Health, Neuherberg, 85764, Germany
| | - Annette Feuchtinger
- Research Unit Analytical Pathology, Helmholtz Zentrum München, Neuherberg, 85764, Germany
| | - Lorenz Hehn
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, 85748, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, München, 81675, Germany
| | - Martin Donnelley
- Robinson Research Institute and Adelaide Medical School, University of Adelaide, Adelaide, 5000, Australia
- Respiratory and Sleep Medicine, Women's and Children's Hospital, North Adelaide, SA, 5006, Australia
| | - Benedikt Günther
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, 85748, Germany
- Munich School of BioEngineering, Technical University of Munich, Garching, 85748, Germany
| | - Klaus Achterhold
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, 85748, Germany
- Munich School of BioEngineering, Technical University of Munich, Garching, 85748, Germany
| | - Axel Walch
- Research Unit Analytical Pathology, Helmholtz Zentrum München, Neuherberg, 85764, Germany
| | - Tobias Stoeger
- Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, 81377, Germany
- Institute of Lung Biology and Disease, Helmholtz Zentrum München-German Research Center for Environmental Health, Neuherberg, 85764, Germany
| | - Daniel Razansky
- Faculty of Medicine, Technical University of Munich, Munich, 80333, Germany
- Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg, 85764, Germany
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Zurich, CH-8057, Switzerland
- Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich, 8093, Switzerland
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, 85748, Germany
- Munich School of BioEngineering, Technical University of Munich, Garching, 85748, Germany
- Institute for Advanced Study, Technical University of Munich, Garching, 85748, Germany
- Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, München, 81675, Germany
| | - Kaye S Morgan
- Chair of Biomedical Physics, Department of Physics, Technical University of Munich, Garching, 85748, Germany
- Institute for Advanced Study, Technical University of Munich, Garching, 85748, Germany
- School of Physics and Astronomy, Monash University, Clayton, Victoria, 3800, Australia
| | - Otmar Schmid
- Comprehensive Pneumology Center (CPC-M), Member of the German Center for Lung Research (DZL), Munich, 81377, Germany
- Institute of Lung Biology and Disease, Helmholtz Zentrum München-German Research Center for Environmental Health, Neuherberg, 85764, Germany
| |
Collapse
|
17
|
Gradl R, Dierolf M, Yang L, Hehn L, Günther B, Möller W, Kutschke D, Stoeger T, Gleich B, Achterhold K, Donnelley M, Pfeiffer F, Schmid O, Morgan KS. Visualizing treatment delivery and deposition in mouse lungs using in vivo x-ray imaging. J Control Release 2019; 307:282-291. [DOI: 10.1016/j.jconrel.2019.06.035] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 06/18/2019] [Accepted: 06/25/2019] [Indexed: 01/17/2023]
|
18
|
Imaging features in post-mortem x-ray dark-field chest radiographs and correlation with conventional x-ray and CT. Eur Radiol Exp 2019; 3:25. [PMID: 31292790 PMCID: PMC6620231 DOI: 10.1186/s41747-019-0104-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 05/29/2019] [Indexed: 02/01/2023] Open
Abstract
Background Although x-ray dark-field imaging has been intensively investigated for lung imaging in different animal models, there is very limited data about imaging features in the human lungs. Therefore, in this work, a reader study on nine post-mortem human chest x-ray dark-field radiographs was performed to evaluate dark-field signal strength in the lungs, intraobserver and interobserver agreement, and image quality and to correlate with findings of conventional x-ray and CT. Methods In this prospective work, chest x-ray dark-field radiography with a tube voltage of 70 kVp was performed post-mortem on nine humans (3 females, 6 males, age range 52–88 years). Visual quantification of dark-field and transmission signals in the lungs was performed by three radiologists. Results were compared to findings on conventional x-rays and 256-slice computed tomography. Image quality was evaluated. For ordinal data, median, range, and dot plots with medians and 95% confidence intervals are presented; intraobserver and interobserver agreement were determined using weighted Cohen κ. Results Dark-field signal grading showed significant differences between upper and middle (p = 0.004–0.016, readers 1–3) as well as upper and lower zones (p = 0.004–0.016, readers 1–2). Median transmission grading was indifferent between all lung regions. Intraobserver and interobserver agreements were substantial to almost perfect for grading of both dark-field (κ = 0.793–0.971 and κ = 0.828–0.893) and transmission images (κ = 0.790–0.918 and κ = 0.700–0.772). Pulmonary infiltrates correlated with areas of reduced dark-field signal. Image quality was rated good for dark-field images. Conclusions Chest x-ray dark-field images provide information of the lungs complementary to conventional x-ray and allow reliable visual quantification of dark-field signal strength. Electronic supplementary material The online version of this article (10.1186/s41747-019-0104-7) contains supplementary material, which is available to authorized users.
Collapse
|
19
|
Vignero J, Marshall NW, Vande Velde G, Bliznakova K, Bosmans H. Translation from murine to human lung imaging using x-ray dark field radiography: A simulation study. PLoS One 2018; 13:e0206302. [PMID: 30372458 PMCID: PMC6205805 DOI: 10.1371/journal.pone.0206302] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 10/10/2018] [Indexed: 02/01/2023] Open
Abstract
Recent studies on murine models have demonstrated the potential of dark field (DF) x-ray imaging for lung diseases. The alveolar microstructure causes small angle scattering, which is visualised in DF images. Whether DF imaging works for human lungs is not a priori guaranteed as human alveoli are larger and system settings for murine imaging will probably have to be adapted. This work examines the potential of translating DF imaging to human lungs. The DF contrast due to murine and human lung models was studied using numerical wave propagation simulations, where the lungs were modelled as a volume filled with spheres. Three sphere diameters were used: 39, 60 and 80 μm for the murine model and 200, 300 and 400 μm spheres for the human model. System settings applied for murine lung response modelling were taken from a prototype grating interferometry scanner used in murine lung experiments. The settings simulated for human lung imaging simulations combine the requirements for grating interferometry and conventional chest RX in terms of x-ray energy and pixel size. The DF signal in the simulated murine model was consistent with results from experimental DF data. The simulated linear diffusion coefficient for medium alveoli diameters was found to be (1.31±0.01)⋅10-11 mm-1, 120 times larger than those of human lung tissue ((1.09±0.01)⋅10-13 mm-1). However, as the human thorax is typically a factor 15 times larger than that of murine animals, the overall DF effect in human lungs remains substantial. At the largest lung thickness and for the DF setup simulated, human lungs have an estimated DF response of around 0.31 and murine lungs of 0.23. Dark field imaging can therefore be considered a promising modality for use in human lung imaging.
Collapse
Affiliation(s)
- Janne Vignero
- Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
| | - Nicholas W. Marshall
- Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
- Department of Radiology, UZ Leuven, Leuven, Belgium
| | | | - Kristina Bliznakova
- Laboratory of Computer Simulations in Medicine, Technical University of Varna, Varna, Bulgaria
| | - Hilde Bosmans
- Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
- Department of Radiology, UZ Leuven, Leuven, Belgium
| |
Collapse
|
20
|
Hauke C, Bartl P, Leghissa M, Ritschl L, Sutter SM, Weber T, Zeidler J, Freudenberger J, Mertelmeier T, Radicke M, Michel T, Anton G, Meinel FG, Baehr A, Auweter S, Bondesson D, Gaass T, Dinkel J, Reiser M, Hellbach K. A preclinical Talbot-Lau prototype for x-ray dark-field imaging of human-sized objects. Med Phys 2018; 45:2565-2571. [DOI: 10.1002/mp.12889] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 03/09/2018] [Accepted: 03/09/2018] [Indexed: 12/13/2022] Open
Affiliation(s)
- C. Hauke
- Siemens Healthcare GmbH; 91301 Forchheim Germany
- Erlangen Centre for Astroparticle Physics; FAU Erlangen-Nuremberg; 91058 Erlangen Germany
| | - P. Bartl
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - M. Leghissa
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - L. Ritschl
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - S. M. Sutter
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - T. Weber
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - J. Zeidler
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | | | | | - M. Radicke
- Siemens Healthcare GmbH; 91301 Forchheim Germany
| | - T. Michel
- Erlangen Centre for Astroparticle Physics; FAU Erlangen-Nuremberg; 91058 Erlangen Germany
| | - G. Anton
- Erlangen Centre for Astroparticle Physics; FAU Erlangen-Nuremberg; 91058 Erlangen Germany
| | - F. G. Meinel
- Department of Diagnostic and Interventional Radiology; University of Rostock Medical Center; 18057 Rostock Germany
| | - A. Baehr
- Department of Veterinary Science; LMU Munich; 85764 Oberschleissheim Germany
| | - S. Auweter
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - D. Bondesson
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - T. Gaass
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - J. Dinkel
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - M. Reiser
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| | - K. Hellbach
- Department of Radiology; University Hospital; LMU Munich; 80336 Munich Germany
| |
Collapse
|
21
|
Pfeiffer F, Reiser M, Rummeny E. [X‑ray Phase Contrast : Principles, potential and advances in clinical translation]. Radiologe 2018; 58:218-225. [PMID: 29374312 DOI: 10.1007/s00117-018-0357-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
More than 100 years ago Max von Laue in Munich discovered that X‑rays can be interpreted not only as X‑ray quanta in a particle picture, but also show a wave character. This property has been used for a long time in basic research (e.g. in crystallography for determining the structure of proteins), but so far has had no application in medical imaging. In the last 10 years, however, very impressive technological progress could be made in preclinical research, which also makes the utilization of the wave character of X‑ray light possible for medical imaging. These novel radiography procedures, so-called phase-contrast and dark-field imaging, have a great potential for a pronounced improvement in X‑ray imaging and therefore, also the diagnosis of important diseases. This article describes the basic principles of these novel procedures, summarizes the preclinical research results already achieved exemplified by various organs and shows the potential for future clinical utilization in radiography and computed tomography.
Collapse
Affiliation(s)
- F Pfeiffer
- Lehrstuhl für Biomedizinische Physik, Department Physik & Munich School of BioEngineering, Technische Universität München, München, Deutschland. .,Institut für diagnostische und interventionelle Radiologie, Klinikum rechts der Isar, Technische Universität München, München, Deutschland.
| | - M Reiser
- Klinik und Poliklinik für Radiologie, Klinikum der Universität, Ludwig-Maximilians-Universität München, München, Deutschland
| | - E Rummeny
- Institut für diagnostische und interventionelle Radiologie, Klinikum rechts der Isar, Technische Universität München, München, Deutschland
| |
Collapse
|
22
|
Aulakh GK, Mann A, Belev G, Wiebe S, Kuebler WM, Singh B, Chapman D. Multiple image x-radiography for functional lung imaging. Phys Med Biol 2017; 63:015009. [PMID: 29116051 DOI: 10.1088/1361-6560/aa9904] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Detection and visualization of lung tissue structures is impaired by predominance of air. However, by using synchrotron x-rays, refraction of x-rays at the interface of tissue and air can be utilized to generate contrast which may in turn enable quantification of lung optical properties. We utilized multiple image radiography, a variant of diffraction enhanced imaging, at the Canadian light source to quantify changes in unique x-ray optical properties of lungs, namely attenuation, refraction and ultra small-angle scatter (USAXS or width) contrast ratios as a function of lung orientation in free-breathing or respiratory-gated mice before and after intra-nasal bacterial endotoxin (lipopolysaccharide) instillation. The lung ultra small-angle scatter and attenuation contrast ratios were significantly higher 9 h post lipopolysaccharide instillation compared to saline treatment whereas the refraction contrast decreased in magnitude. In ventilated mice, end-expiratory pressures result in an increase in ultra small-angle scatter contrast ratio when compared to end-inspiratory pressures. There were no detectable changes in lung attenuation or refraction contrast ratio with change in lung pressure alone. In effect, multiple image radiography can be applied towards following optical properties of lung air-tissue barrier over time during pathologies such as acute lung injury.
Collapse
Affiliation(s)
- G K Aulakh
- Small Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, Canada
| | | | | | | | | | | | | |
Collapse
|
23
|
Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography. Invest Radiol 2017; 51:597-601. [PMID: 27603110 DOI: 10.1097/rli.0000000000000285] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE The aim of this study was to evaluate the diagnostic value of x-ray dark-field imaging in projection radiography-based depiction of pneumothoraces in the neonatal murine lung, a potentially life-threatening medical condition that requires a timely and correct diagnosis. MATERIALS AND METHODS By the use of a unique preclinical model, 7-day-old C57Bl/6N mice received mechanical ventilation for 2 or 8 hours with oxygen-rich gas (FIO2 = 0.4; n = 24). Unventilated mice either spontaneously breathed oxygen-rich gas (FIO2 = 0.4) for 2 or 8 hours or room air (n = 22). At the end of the experiment, lungs were inflated with a standardized volume of air after a lethal dose of pentobarbital was administered to the pups. All lungs were imaged with a prototype grating-based small-animal scanner to acquire x-ray transmission and dark-field radiographs. Image contrast between the air-filled pleural space and lung tissue was quantified for both transmission and dark-field radiograms. After the independent expert's assessment, 2 blinded readers evaluated all dark-field and transmission images for the presence or absence of pneumothoraces. Contrast ratios, diagnostic accuracy, as well as reader's confidence and interreader agreement were recorded for both imaging modalities. RESULTS Evaluation of both x-ray transmission and dark-field radiographs by independent experts revealed the development of a total of 10 pneumothoraces in 8 mice. Here, the contrast ratio between the air-filled pleural space of the pneumothoraces and the lung tissue was significantly higher in the dark field (8.4 ± 3.5) when compared with the transmission images (5.1 ± 2.8; P < 0.05). Accordingly, the readers' diagnostic confidence for the diagnosis of pneumothoraces was significantly higher for dark-field compared with transmission images (P = 0.001). Interreader agreement improved from moderate for the analysis of transmission images alone (κ = 0.41) to very good when analyzing dark-field images alone (κ = 0.90) or in combination with transmission images (κ = 0.88). Diagnostic accuracy significantly improved for the analysis of dark-field images alone (P = 0.04) or in combination with transmission images (P = 0.02), compared with the analysis of transmission radiographs only. CONCLUSIONS The significant improvement in contrast ratios between lung parenchyma and free air in the dark-field images allows the facilitated detection of pneumothoraces in the newborn mouse. These preclinical experiments indicate the potential of the technique for future clinical applications.
Collapse
|
24
|
Abstract
OBJECTIVES The aim of this study was to evaluate the suitability of in vivo x-ray dark-field radiography for early-stage diagnosis of pulmonary emphysema in mice. Furthermore, we aimed to analyze how the dark-field signal correlates with morphological changes of lung architecture at distinct stages of emphysema. MATERIALS AND METHODS Female 8- to 10-week-old C57Bl/6N mice were used throughout all experiments. Pulmonary emphysema was induced by orotracheal injection of porcine pancreatic elastase (80-U/kg body weight) (n = 30). Control mice (n = 11) received orotracheal injection of phosphate-buffered saline. To monitor the temporal patterns of emphysema development over time, the mice were imaged 7, 14, or 21 days after the application of elastase or phosphate-buffered saline. X-ray transmission and dark-field images were acquired with a prototype grating-based small-animal scanner. In vivo pulmonary function tests were performed before killing the animals. In addition, lungs were obtained for detailed histopathological analysis, including mean cord length (MCL) quantification as a parameter for the assessment of emphysema. Three blinded readers, all of them experienced radiologists and familiar with dark-field imaging, were asked to grade the severity of emphysema for both dark-field and transmission images. RESULTS Histopathology and MCL quantification confirmed the introduction of different stages of emphysema, which could be clearly visualized and differentiated on the dark-field radiograms, whereas early stages were not detected on transmission images. The correlation between MCL and dark-field signal intensities (r = 0.85) was significantly higher than the correlation between MCL and transmission signal intensities (r = 0.37). The readers' visual ratings for dark-field images correlated significantly better with MCL (r = 0.85) than visual ratings for transmission images (r = 0.36). Interreader agreement and the diagnostic accuracy of both quantitative and visual assessment were significantly higher for dark-field imaging than those for conventional transmission images. CONCLUSIONS X-ray dark-field radiography can reliably visualize different stages of emphysema in vivo and demonstrates significantly higher diagnostic accuracy for early stages of emphysema than conventional attenuation-based radiography.
Collapse
|
25
|
Trimborn B, Meyer P, Kunka D, Zuber M, Albrecht F, Kreuer S, Volk T, Baumbach T, Koenig T. Imaging properties of high aspect ratio absorption gratings for use in preclinical x-ray grating interferometry. Phys Med Biol 2015; 61:527-41. [PMID: 26683256 DOI: 10.1088/0031-9155/61/2/527] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
X-ray grating interferometry is one among various methods that allow extracting the so-called phase and visibility contrasts in addition to the well-known transmission images. Crucial to achieving a high image quality are the absorption gratings employed. Here, we present an in-depth analysis of how the grating type and lamella heights influence the final images. Benchmarking gratings of two different designs, we show that a frequently used proxy for image quality, a grating's so-called visibility, is insufficient to predict contrast-to-noise ratios (CNRs). Presenting scans from an excised rat lung, we demonstrate that the CNRs obtained for transmission and visibility images anti-correlate. This is explained by the stronger attenuation implied by gratings that are engineered to provide high visibilities by means of an increased lamella height. We show that even the visibility contrast can suffer from this effect when the associated reduced photon flux on the detector is not outweighed by a corresponding gain in visibility. Resulting in an inevitable trade-off between the quality of the two contrasts, the question of how an optimal grating should be designed can hence only be answered in terms of Pareto optimality.
Collapse
Affiliation(s)
- Barbara Trimborn
- Institute for Photon Science and Synchrotron Radiation (IPS) & ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Kitchen MJ, Buckley GA, Leong AFT, Carnibella RP, Fouras A, Wallace MJ, Hooper SB. X-ray specks: low dose in vivo imaging of lung structure and function. Phys Med Biol 2015; 60:7259-76. [PMID: 26348552 DOI: 10.1088/0031-9155/60/18/7259] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Respiratory health is directly linked to the structural and mechanical properties of the airways of the lungs. For studying respiratory development and pathology, the ability to quantitatively measure airway dimensions and changes in their size during respiration is highly desirable. Real-time imaging of the terminal airways with sufficient contrast and resolution during respiration is currently not possible. Herein we reveal a simple method for measuring lung airway dimensions in small animals during respiration from a single propagation-based phase contrast x-ray image, thereby requiring minimal radiation. This modality renders the lungs visible as a speckled intensity pattern. In the near-field regime, the size of the speckles is directly correlated with that of the dominant length scale of the airways. We demonstrate that Fourier space quantification of the speckle texture can be used to statistically measure regional airway dimensions at the alveolar scale, with measurement precision finer than the spatial resolution of the imaging system. Using this technique we discovered striking differences in developmental maturity in the lungs of rabbit kittens at birth.
Collapse
Affiliation(s)
- Marcus J Kitchen
- School of Physics and Astronomy, Monash University, Clayton, Victoria, Australia
| | | | | | | | | | | | | |
Collapse
|
27
|
Abstract
OBJECTIVES The purpose of this study was to assess whether the recently developed method of grating-based x-ray dark-field radiography can improve the diagnosis of pulmonary emphysema in vivo. MATERIALS AND METHODS Pulmonary emphysema was induced in female C57BL/6N mice using endotracheal instillation of porcine pancreatic elastase and confirmed by in vivo pulmonary function tests, histopathology, and quantitative morphometry. The mice were anesthetized but breathing freely during imaging. Experiments were performed using a prototype small-animal x-ray dark-field scanner that was operated at 35 kilovolt (peak) with an exposure time of 5 seconds for each of the 10 grating steps. Images were compared visually. For quantitative comparison of signal characteristics, regions of interest were placed in the upper, middle, and lower zones of each lung. Receiver-operating-characteristic statistics were performed to compare the effectiveness of transmission and dark-field signal intensities and the combined parameter "normalized scatter" to differentiate between healthy and emphysematous lungs. RESULTS A clear visual difference between healthy and emphysematous mice was found for the dark-field images. Quantitative measurements of x-ray dark-field signal and normalized scatter were significantly different between the mice with pulmonary emphysema and the control mice and showed good agreement with pulmonary function tests and quantitative histology. The normalized scatter showed a significantly higher discriminatory power (area under the receiver-operating-characteristic curve [AUC], 0.99) than dark-field (AUC, 0.90; P = 0.01) or transmission signal (AUC, 0.69; P < 0.001) alone did, allowing for an excellent discrimination of healthy and emphysematous lung regions. CONCLUSIONS In a murine model, x-ray dark-field radiography is technically feasible in vivo and represents a substantial improvement over conventional transmission-based x-ray imaging for the diagnosis of pulmonary emphysema.
Collapse
|
28
|
Strengell S, Keyriläinen J, Suortti P, Bayat S, Sovijärvi ARA, Porra L. Radiation dose and image quality in K-edge subtraction computed tomography of lung in vivo. JOURNAL OF SYNCHROTRON RADIATION 2014; 21:1305-1313. [PMID: 25343799 DOI: 10.1107/s160057751401697x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Accepted: 07/23/2014] [Indexed: 06/04/2023]
Abstract
K-edge subtraction computed tomography (KES-CT) allows simultaneous imaging of both structural features and regional distribution of contrast elements inside an organ. Using this technique, regional lung ventilation and blood volume distributions can be measured experimentally in vivo. In order for this imaging technology to be applicable in humans, it is crucial to minimize exposure to ionizing radiation with little compromise in image quality. The goal of this study was to assess the changes in signal-to-noise ratio (SNR) of KES-CT lung images as a function of radiation dose. The experiments were performed in anesthetized and ventilated rabbits using inhaled xenon gas in O2 at two concentrations: 20% and 70%. Radiation dose, defined as air kerma (Ka), was measured free-in-air and in a 16 cm polymethyl methacrylate phantom with a cylindrical ionization chamber. The dose free-in-air was varied from 2.7 mGy to 8.0 Gy. SNR in the images of xenon in air spaces was above the Rose criterion (SNR > 5) when Ka was over 400 mGy with 20% xenon, and over 40 mGy with 70% xenon. Although in human thorax attenuation is higher, based on these findings it is estimated that, by optimizing the imaging sequence and reconstruction algorithms, the radiation dose could be further reduced to clinically acceptable levels.
Collapse
Affiliation(s)
- S Strengell
- Department of Physics, University of Helsinki, Helsinki 00370, Finland
| | - J Keyriläinen
- Department of Oncology, Helsinki University Central Hospital, Helsinki, Finland
| | - P Suortti
- Department of Physics, University of Helsinki, Helsinki 00370, Finland
| | - S Bayat
- Université de Picardie Jules Verne, Inserm U1105 and CHU Amiens, France
| | - A R A Sovijärvi
- Department of Clinical Physiology and Nuclear Medicine, Helsinki University Central Hospital, Helsinki, Finland
| | - L Porra
- Department of Physics, University of Helsinki, Helsinki 00370, Finland
| |
Collapse
|
29
|
Velroyen A, Bech M, Zanette I, Schwarz J, Rack A, Tympner C, Herrler T, Staab-Weijnitz C, Braunagel M, Reiser M, Bamberg F, Pfeiffer F, Notohamiprodjo M. X-ray phase-contrast tomography of renal ischemia-reperfusion damage. PLoS One 2014; 9:e109562. [PMID: 25299243 PMCID: PMC4192129 DOI: 10.1371/journal.pone.0109562] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2014] [Accepted: 09/02/2014] [Indexed: 01/28/2023] Open
Abstract
Purpose The aim of the study was to investigate microstructural changes occurring in unilateral renal ischemia-reperfusion injury in a murine animal model using synchrotron radiation. Material and Methods The effects of renal ischemia-reperfusion were investigated in a murine animal model of unilateral ischemia. Kidney samples were harvested on day 18. Grating-Based Phase-Contrast Imaging (GB-PCI) of the paraffin-embedded kidney samples was performed at a Synchrotron Radiation Facility (beam energy of 19 keV). To obtain phase information, a two-grating Talbot interferometer was used applying the phase stepping technique. The imaging system provided an effective pixel size of 7.5 µm. The resulting attenuation and differential phase projections were tomographically reconstructed using filtered back-projection. Semi-automated segmentation and volumetry and correlation to histopathology were performed. Results GB-PCI provided good discrimination of the cortex, outer and inner medulla in non-ischemic control kidneys. Post-ischemic kidneys showed a reduced compartmental differentiation, particularly of the outer stripe of the outer medulla, which could not be differentiated from the inner stripe. Compared to the contralateral kidney, after ischemia a volume loss was detected, while the inner medulla mainly retained its volume (ratio 0.94). Post-ischemic kidneys exhibited severe tissue damage as evidenced by tubular atrophy and dilatation, moderate inflammatory infiltration, loss of brush borders and tubular protein cylinders. Conclusion In conclusion GB-PCI with synchrotron radiation allows for non-destructive microstructural assessment of parenchymal kidney disease and vessel architecture. If translation to lab-based approaches generates sufficient density resolution, and with a time-optimized image analysis protocol, GB-PCI may ultimately serve as a non-invasive, non-enhanced alternative for imaging of pathological changes of the kidney.
Collapse
Affiliation(s)
- Astrid Velroyen
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Martin Bech
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
- Medical Radiation Physics, Lund University, Lund, Sweden
| | - Irene Zanette
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Jolanda Schwarz
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Alexander Rack
- European Synchrotron Radiation Facility, Grenoble, France
| | - Christiane Tympner
- Institute of Pathology, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Tanja Herrler
- Department of General, Trauma, Hand, and Plastic Surgery, Ludwig-Maximilians-University Hospital Munich, Munich, Germany
| | - Claudia Staab-Weijnitz
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
- Comprehensive Pneumology Center, University Hospital, Ludwig-Maximilians-University and Helmholtz Zentrum Munich, Munich, Germany
| | - Margarita Braunagel
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
| | - Maximilian Reiser
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
| | - Fabian Bamberg
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
- Department of Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Franz Pfeiffer
- Chair of Biomedical Physics, Department of Physics (E17), Munich, Bavaria, Germany
| | - Mike Notohamiprodjo
- Institute for Clinical Radiology, University Hospitals Munich, Munich, Germany
- Department of Radiology, University Hospital Tuebingen, Tuebingen, Germany
- * E-mail:
| |
Collapse
|
30
|
Subnanoradian X-ray phase-contrast imaging using a far-field interferometer of nanometric phase gratings. Nat Commun 2014; 4:2659. [PMID: 24189696 PMCID: PMC3831282 DOI: 10.1038/ncomms3659] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2013] [Accepted: 09/23/2013] [Indexed: 12/04/2022] Open
Abstract
Hard X-ray phase-contrast imaging characterizes the electron density distribution in an object without the need for radiation absorption. The power of phase contrast to resolve subtle changes, such as those in soft tissue structures, lies in its ability to detect minute refractive bending of X-rays. Here we report a far-field, two-arm interferometer based on the new nanometric phase gratings, which can detect X-ray refraction with subnanoradian sensitivity, and at the same time overcomes the fundamental limitation of ultra-narrow bandwidths (Δλ/λ~10−4) of the current, most sensitive methods based on crystal interferometers. On a 1.5% bandwidth synchrotron source, we demonstrate clear visualization of blood vessels in unstained mouse organs in simple projection views, with over an order-of-magnitude higher phase contrast than current near-field grating interferometers. Phase-contrast imaging has become popular for medical diagnostic purposes because of the ability to see transparent structures at relatively small radiation energy dosed to samples. Wen et al. further develop this technique using nanometric phase gratings to achieve subnanoradian sensitivity.
Collapse
|
31
|
Yaroshenko A, Hellbach K, Bech M, Grandl S, Reiser MF, Pfeiffer F, Meinel FG. Grating-based X-ray dark-field imaging: a new paradigm in radiography. CURRENT RADIOLOGY REPORTS 2014. [DOI: 10.1007/s40134-014-0057-9] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
32
|
|
33
|
Bech M, Tapfer A, Velroyen A, Yaroshenko A, Pauwels B, Hostens J, Bruyndonckx P, Sasov A, Pfeiffer F. In-vivo dark-field and phase-contrast x-ray imaging. Sci Rep 2013; 3:3209. [PMID: 24220606 PMCID: PMC3826096 DOI: 10.1038/srep03209] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Accepted: 10/29/2013] [Indexed: 02/06/2023] Open
Abstract
Novel radiography approaches based on the wave nature of x-rays when propagating through matter have a great potential for improved future x-ray diagnostics in the clinics. Here, we present a significant milestone in this imaging method: in-vivo multi-contrast x-ray imaging of a mouse using a compact scanner. Of particular interest is the enhanced contrast in regions related to the respiratory system, indicating a possible application in diagnosis of lung diseases (e.g. emphysema).
Collapse
Affiliation(s)
- M Bech
- 1] Physics Department & Institute for Medical Engineering, Technische Universität München, 85748 Garching, Germany [2] Medical Radiation Physics, Lund University, 221 85 Lund, Sweden
| | | | | | | | | | | | | | | | | |
Collapse
|