1
|
Ishizaki Y, Wang J, Kim J, Matsumoto T, Maeda E. Contributions of collagen and elastin to elastic behaviours of tendon fascicle. Acta Biomater 2024; 176:334-343. [PMID: 38237712 DOI: 10.1016/j.actbio.2024.01.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 01/02/2024] [Accepted: 01/11/2024] [Indexed: 02/03/2024]
Abstract
Tendon exhibits the capacity to be stretched and to return to its original length without suffering structural damage in vivo, a capacity known as elastic recoil. Collagen fibres are aligned longitudinally and elastin fibres mostly run parallel to collagen fibres in tendon. However, their interactions and contributions to tendon elastic behaviours are not well understood. The present study examined functional roles of collagen and elastin in tendon elastic behaviours using a variety of mechanical tests. We prepared three types of fascicle specimens from mouse tail tendon: fascicles freshly isolated, those digested with elastase in PBS to selectively remove elastin, and those incubated in PBS without elastase. A quasi-static tensile test demonstrated that elastase-treated fascicles had higher tangent moduli and strength compared to fresh and PBS fascicles. Cyclic stretching tests showed that fresh and PBS fascicles could withstand cyclic strain at both small and large amplitudes, but elastase-treated fascicles could only behave elastically to a limited degree. Fibre-sliding analysis revealed that fresh fascicles could be elongated both through stretching of collagen fibers and through movement of the fibres. However, elastase-treated fascicles could be stretched only via fibre stretching. This evidence suggests that normal tendons can be extended through both fibre stretching and fibre sliding, whereas tendons without elastin can only extend as much as collagen fibers can withstand. Accordingly, collagen fibres mainly contribute to tendon elastic behaviours by furnishing rigidity and elasticity, whereas elastin provides tendon viscoelasticity and also enables sliding of collagen fibres during elastic behaviours. STATEMENT OF SIGNIFICANCE: The present study revealed distinct mechanical functions of collagen and elastin fibres in elastic behaviours of mouse tail tendon fascicle using a variety of mechanical tests at both microscopic and macroscopic levels. It was demonstrated that collagen mainly governs tendon fascicle rigidity and elasticity, but only possesses limited extensibility, whereas elastin contributes to viscoelasticity and collagen fibre sliding, enabling elastic recoil behaviour against relatively large deformation. By their interactions, tendon can be elongated without suffering major structural damage and withstand a large magnitude of tensile force in response to mechanical loading. Such information should be particularly useful in designing collagen-based biomaterials such as artificial tendons, in that previous studies have merely considered collagen without incorporation of elastin.
Collapse
Affiliation(s)
- Yusei Ishizaki
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Aichi, Japan
| | - Junfeng Wang
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Aichi, Japan
| | - Jeonghyun Kim
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Aichi, Japan
| | - Takeo Matsumoto
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Aichi, Japan
| | - Eijiro Maeda
- Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Aichi, Japan.
| |
Collapse
|
2
|
Voce GT, Michalek AJ. Fluorescent labeling with 5-DTAF reduces collagen fiber uncrimping in loaded tendons. J Mech Behav Biomed Mater 2023; 138:105646. [PMID: 36580857 DOI: 10.1016/j.jmbbm.2022.105646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 12/14/2022] [Accepted: 12/26/2022] [Indexed: 12/28/2022]
Abstract
A fluorescent dye commonly used to image tissues under load (5-DTAF) has previously been shown to stiffen tendons. This study hypothesized that 5-DTAF staining stiffens tendons through reduced fiber sliding, altering the rate at which crimped collagen fibers straighten under load. This was tested by using reflected cross-polarized light microscopy to measure fiber crimp period of cervine extensor digitorum longus tendon specimens under axial load. Specimens were treated with either phosphate buffered saline (negative control), genipin (positive control), or 5-DTAF. In saline treated specimens, crimp period (relative to unstretched) increased at approximately 2.5 times the applied axial strain, indicating substantial fiber sliding. In both 5-DTAF and genipin treated specimens, this ratio was reduced to 1:1, indicating no fiber sliding. These results add further evidence that care should be taken when using 5-DTAF to stain tissue for studying microscale deformations in tissues.
Collapse
Affiliation(s)
- Gianna T Voce
- Department of Computer Science, Clarkson University, Potsdam, NY, USA
| | - Arthur J Michalek
- Department of Mechanical & Aerospace Engineering, Clarkson University, Potsdam, NY, USA.
| |
Collapse
|
3
|
Disney C, Mo J, Eckersley A, Bodey A, Hoyland J, Sherratt M, Pitsillides A, Lee P, Bay B. Regional variations in discrete collagen fibre mechanics within intact intervertebral disc resolved using synchrotron computed tomography and digital volume correlation. Acta Biomater 2022; 138:361-374. [PMID: 34644611 PMCID: PMC8904373 DOI: 10.1016/j.actbio.2021.10.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 10/01/2021] [Accepted: 10/06/2021] [Indexed: 01/14/2023]
Abstract
Many soft tissues, such as the intervertebral disc (IVD), have a hierarchical fibrous composite structure which suffers from regional damage. We hypothesise that these tissue regions have distinct, inherent fibre structure and structural response upon loading. Here we used synchrotron computed tomography (sCT) to resolve collagen fibre bundles (∼5μm width) in 3D throughout an intact native rat lumbar IVD under increasing compressive load. Using intact samples meant that tissue boundaries (such as endplate-disc or nucleus-annulus) and residual strain were preserved; this is vital for characterising both the inherent structure and structural changes upon loading in tissue regions functioning in a near-native environment. Nano-scale displacement measurements along >10,000 individual fibres were tracked, and fibre orientation, curvature and strain changes were compared between the posterior-lateral region and the anterior region. These methods can be widely applied to other soft tissues, to identify fibre structures which cause tissue regions to be more susceptible to injury and degeneration. Our results demonstrate for the first time that highly-localised changes in fibre orientation, curvature and strain indicate differences in regional strain transfer and mechanical function (e.g. tissue compliance). This included decreased fibre reorientation at higher loads, specific tissue morphology which reduced capacity for flexibility and high strain at the disc-endplate boundary. Statement of significance The analyses presented here are applicable to many collagenous soft tissues which suffer from regional damage. We aimed to investigate regional intervertebral disc (IVD) structural and functional differences by characterising collagen fibre architecture and linking specific fibre- and tissue-level deformation behaviours. Synchrotron CT provided the first demonstration of tracking discrete fibres in 3D within an intact IVD. Detailed analysis of regions was performed using over 200k points, spaced every 8 μm along 10k individual fibres. Such comprehensive structural characterisation is significant in informing future computational models. Morphological indicators of tissue compliance (change in fibre curvature and orientation) and fibre strain measurements revealed localised and regional differences in tissue behaviour.
Collapse
|
4
|
Sibole SC, Moo EK, Federico S, Herzog W. The Protective Function of Directed Asymmetry in the Pericellular Matrix Enveloping Chondrocytes. Ann Biomed Eng 2022; 50:39-55. [PMID: 34993700 DOI: 10.1007/s10439-021-02900-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 12/01/2021] [Indexed: 01/10/2023]
Abstract
The specialized pericellular matrix (PCM) surrounding chondrocytes within articular cartilage is critical to the tissue's health and longevity. Growing evidence suggests that PCM alterations are ubiquitous across all trajectories of osteoarthritis, a crippling and prevalent joint disease. The PCM geometry is of particular interest as it influences the cellular mechanical environment. Observations of asymmetrical PCM thickness have been reported, but a quantified characterization is lacking. To this end, a novel microscopy protocol was developed and applied to acquire images of the PCM surrounding live cells. Morphometric analysis indicated a statistical bias towards thicker PCM on the inferior cellular surface. The mechanical effects of this bias were investigated with multiscale modelling, which revealed potentially damaging, high tensile strains in the direction perpendicular to the membrane and localized on the inferior surface. These strains varied substantially between PCM asymmetry cases. Simulations with a thicker inferior PCM, representative of the observed geometry, resulted in strain magnitudes approximately half of those calculated for a symmetric geometry, and a third of those with a thin inferior PCM. This strain attenuation suggests that synthesis of a thicker inferior PCM may be a protective adaptation. PCM asymmetry may thus be important in cartilage development, pathology, and engineering.
Collapse
Affiliation(s)
- Scott C Sibole
- Human Performance Laboratory, University of Calgary, Calgary, Canada.
| | - Eng Kuan Moo
- Human Performance Laboratory, University of Calgary, Calgary, Canada.,Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Salvatore Federico
- Human Performance Laboratory, University of Calgary, Calgary, Canada.,Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Canada
| | - Walter Herzog
- Human Performance Laboratory, University of Calgary, Calgary, Canada.,Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, Canada
| |
Collapse
|
5
|
Khin MNOE, Ahammed S, Zhong F. Development of (5-(4,6-dichlorotriazinyl) aminofluorescein) DTAF-labelled polysaccharides for characterization of microstructure and phase distribution of composite hydrogel visualization of hydrogels using CLSM. FOOD BIOSCI 2021. [DOI: 10.1016/j.fbio.2021.100909] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
6
|
Peterson BE, Szczesny SE. Dependence of tendon multiscale mechanics on sample gauge length is consistent with discontinuous collagen fibrils. Acta Biomater 2020; 117:302-309. [PMID: 33010516 DOI: 10.1016/j.actbio.2020.09.046] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 09/22/2020] [Accepted: 09/24/2020] [Indexed: 12/27/2022]
Abstract
While collagen fibrils are understood to be the primary load-bearing elements in tendon, controversy still exists on how fibrils functionally transmit load from muscle to bone. Specifically, it's unclear whether fibrils are structurally continuous along the tendon length and bear load independently, or if they are discontinuous and transfer load through interfibrillar shear forces. To address this question, we investigated whether the multiscale mechanics of rat tail tendon fascicles is dependent on sample gauge length. We hypothesized that as the grip-to-grip length is reduced and approaches the length of the collagen fibrils, tendon fascicles will adopt a multiscale mechanical response consistent with structurally continuous fibrils. Our findings show that, for gauge lengths of 20 mm or greater, the local fibril strains are less than the bulk tissue strains, which can be explained by relative sliding between discontinuous collagen fibrils. In contrast, at a 5 mm gauge length, the fibril strains are equivalent to the applied tissue strains, suggesting that the collagen fibrils are structurally continuous between the grips. Additionally, the macroscale tissue modulus is increased at gauge lengths of 5 and 10 mm. Together, these data support the hypothesis that collagen fibrils in rat tail tendon fascicles are discontinuous and also suggest that their length is between 5 and 10 mm. This fundamental information regarding tendon structure-function relationships underscores the importance of the tissue components that transmit load between fibrils and is critical for understanding tendon pathology as well as establishing structural benchmarks for suitable tissue engineered replacements.
Collapse
|
7
|
Safa BN, Bloom ET, Lee AH, Santare MH, Elliott DM. Evaluation of transverse poroelastic mechanics of tendon using osmotic loading and biphasic mixture finite element modeling. J Biomech 2020; 109:109892. [PMID: 32807341 DOI: 10.1016/j.jbiomech.2020.109892] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 05/15/2020] [Accepted: 06/09/2020] [Indexed: 12/14/2022]
Abstract
Tendon's viscoelastic behaviors are important to the tissue mechanical function and cellular mechanobiology. When loaded in longitudinal tension, tendons often have a large Poisson's ratio (ν>2) that exceeds the limit of incompressibility for isotropic material (ν=0.5), indicating that tendon experiences volume loss, inducing poroelastic fluid exudation in the transverse direction. Therefore, transverse poroelasticity is an important contributor to tendon material behavior. Tendon hydraulic permeability which is required to evaluate the fluid flow contribution to viscoelasticity, is mostly unavailable, and where available, varies by several orders of magnitude. In this manuscript, we quantified the transverse poroelastic material parameters of rat tail tendon fascicles by conducting transverse osmotic loading experiments, in both tension and compression. We used a multi-start optimization method to evaluate the parameters using biphasic finite element modeling. Our tendon samples had a transverse hydraulic permeability of 10-4 to 10-5 mm4. (Ns)-1 and showed a significant tension-compression nonlinearity in the transverse direction. Further, using these results, we predict hydraulic permeability during longitudinal (fiber-aligned) tensile loading, and the spatial distribution of fluid flow during osmotic loading. These results reveal novel aspects of tendon mechanics and can be used to study the physiomechanical response of tendon in response to mechanical loading.
Collapse
Affiliation(s)
- Babak N Safa
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Ellen T Bloom
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Andrea H Lee
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Michael H Santare
- Department of Mechanical Engineering, University of Delaware, Newark, DE, United States; Department of Biomedical Engineering, University of Delaware, Newark, DE, United States
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE, United States.
| |
Collapse
|
8
|
Muench JR, Thelen DG, Henak CR. Interfibrillar shear behavior is altered in aging tendon fascicles. Biomech Model Mechanobiol 2019; 19:841-849. [PMID: 31707625 DOI: 10.1007/s10237-019-01251-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 11/04/2019] [Indexed: 12/11/2022]
Abstract
Tendon elongation involves both stretching and sliding between adjacent fascicles and fibers. Hence, age-related changes in tendon matrix properties may alter sliding behavior and thereby affect injury thresholds. The objective of this study was to investigate the effects of age on interfibrillar shear behavior in partial cut tendon fascicles. Cine microscopic imaging was used to track deformation patterns of intact and partial cut fascicles from mature (9 months, n = 10) and aged (32 months, n = 10) rat tail tendons. Finite element (FE) models coupled with experimental data provided insight into age-related changes in tissue constitutive properties that could give rise to age-dependent behavior. Intact fascicles from aged tendons exhibited a 28% lower linear region modulus and reduced toe region when compared to fascicles from mature tendons. Partial cut tendon fascicles consistently exhibited a shearing plane that extended longitudinally from the tip of the cut. Both mature and aged fascicles exhibited distinct failure that was observable in differential displacement across the shearing plane. However, aged fascicles exhibited 11-20% higher grip-to-grip strain at failure and tended to exhibit more variable and greater differential displacement at failure, when compared to mature fascicles. FE models suggest that this age-related change in shear behavior arises from a reduction in interfibrillar shear modulus with age. These data suggest that aging alters interfibrillar failure mechanisms and hence may contribute to the increased propensity for injury that is commonly seen in older tendons.
Collapse
Affiliation(s)
- Jared R Muench
- Department of Mechanical Engineering, University of Wisconsin-Madison, 3031 Mechanical Engineering Building, 1513 University Avenue, Madison, WI, 53706, USA
| | - Darryl G Thelen
- Department of Mechanical Engineering, University of Wisconsin-Madison, 3031 Mechanical Engineering Building, 1513 University Avenue, Madison, WI, 53706, USA.,Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 Engineering Drive, Madison, WI, USA.,Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, USA
| | - Corinne R Henak
- Department of Mechanical Engineering, University of Wisconsin-Madison, 3031 Mechanical Engineering Building, 1513 University Avenue, Madison, WI, 53706, USA. .,Department of Biomedical Engineering, University of Wisconsin-Madison, 1550 Engineering Drive, Madison, WI, USA. .,Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, USA.
| |
Collapse
|
9
|
Lee AH, Elliott DM. Multi-Scale Loading and Damage Mechanisms of Plantaris and Rat Tail Tendons. J Orthop Res 2019; 37:1827-1837. [PMID: 30977538 PMCID: PMC6790141 DOI: 10.1002/jor.24309] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Revised: 02/21/2019] [Accepted: 03/13/2019] [Indexed: 02/04/2023]
Abstract
Tendinopathy, degeneration of the tendon that leads to pain and dysfunction, is common in both sports and occupational settings, but multi-scale mechanisms for tendinopathy are still unknown. We recently showed that micro-scale sliding (shear) is responsible for both load transfer and damage mechanisms in the rat tail tendon; however, the rat tail tendon is a specialized non-load-bearing tendon, and thus the load transfer and damage mechanisms are still unknown for load-bearing tendons. The objective of this study was to investigate the load transfer and damage mechanisms of load-bearing tendons using the rat plantaris tendon. We demonstrated that micro-scale sliding is a key component for both mechanisms in the plantaris tendon, similar to the tail tendon. Namely, the micro-scale sliding was correlated with applied strain, demonstrating that load was transferred via micro-scale sliding in the plantaris and tail tendons. In addition, while the micro-scale strain fully recovered, the micro-scale sliding was non-recoverable and strain-dependent, and correlated with tissue-scale mechanical parameters. When the applied strain was normalized, the % magnitudes of non-recoverable sliding was similar between the plantaris and tail tendons. Statement of clinical significance: Understanding the mechanisms responsible for the pathogenesis and progression of tendinopathy can improve prevention and rehabilitation strategies and guide therapies and the design of engineered constructs. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1827-1837, 2019.
Collapse
Affiliation(s)
- Andrea H. Lee
- Department of Biomedical Engineering, University of Delaware
| | - Dawn M. Elliott
- Department of Biomedical Engineering, University of Delaware
| |
Collapse
|
10
|
Synchrotron tomography of intervertebral disc deformation quantified by digital volume correlation reveals microstructural influence on strain patterns. Acta Biomater 2019; 92:290-304. [PMID: 31082569 DOI: 10.1016/j.actbio.2019.05.021] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Revised: 05/01/2019] [Accepted: 05/07/2019] [Indexed: 11/22/2022]
Abstract
The intervertebral disc (IVD) has a complex and multiscale extracellular matrix structure which provides unique mechanical properties to withstand physiological loading. Low back pain has been linked to degeneration of the disc but reparative treatments are not currently available. Characterising the disc's 3D microstructure and its response in a physiologically relevant loading environment is required to improve understanding of degeneration and to develop new reparative treatments. In this study, techniques for imaging the native IVD, measuring internal deformation and mapping volumetric strain were applied to an in situ compressed ex vivo rat lumbar spine segment. Synchrotron X-ray micro-tomography (synchrotron CT) was used to resolve IVD structures at microscale resolution. These image data enabled 3D quantification of collagen bundle orientation and measurement of local displacement in the annulus fibrosus between sequential scans using digital volume correlation (DVC). The volumetric strain mapped from synchrotron CT provided a detailed insight into the micromechanics of native IVD tissue. The DVC findings showed that there was no slipping at lamella boundaries, and local strain patterns were of a similar distribution to the previously reported elastic network with some heterogeneous areas and maximum strain direction aligned with bundle orientation, suggesting bundle stretching and sliding. This method has the potential to bridge the gap between measures of macro-mechanical properties and the local 3D micro-mechanical environment experienced by cells. This is the first evaluation of strain at the micro scale level in the intact IVD and provides a quantitative framework for future IVD degeneration mechanics studies and testing of tissue engineered IVD replacements. STATEMENT OF SIGNIFICANCE: Synchrotron in-line phase contrast X-ray tomography provided the first visualisation of native intact intervertebral disc microstructural deformation in 3D. For two annulus fibrosus volumes of interest, collagen bundle orientation was quantified and local displacement mapped as strain. Direct evidence of microstructural influence on strain patterns could be seen such as no slipping at lamellae boundaries and maximum strain direction aligned with collagen bundle orientation. Although disc elastic structures were not directly observed, the strain patterns had a similar distribution to the previously reported elastic network. This study presents technical advances and is a basis for future X-ray microscopy, structural quantification and digital volume correlation strain analysis of soft tissue.
Collapse
|
11
|
Safa B, Lee A, Santare MH, Elliott DM. Evaluating Plastic Deformation and Damage as Potential Mechanisms for Tendon Inelasticity using a Reactive Modeling Framework. J Biomech Eng 2019; 141:2731931. [PMID: 31004138 DOI: 10.1115/1.4043520] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Indexed: 12/12/2022]
Abstract
Inelastic behaviors, such as softening, a progressive decrease in modulus before failure, occur in tendon and are important aspect in degeneration and tendinopathy. These inelastic behaviors are generally attributed to two potential mechanisms: plastic deformation and damage. However, it is not clear which is primarily responsible. In this study, we evaluated these potential mechanisms of tendon inelasticity by using a recently developed reactive inelasticity model (RIE), which is a structurally-inspired continuum mechanics framework that models tissue inelasticity based on the molecular bond kinetics. Using RIE, we formulated two material models, one specific to plastic deformation and the other to damage. The models were independently fit to published experimental tensile tests of rat tail tendons. We quantified the inelastic effects and compared the performance of the two models in fitting the mechanical response during loading, relaxation, unloading, and reloading phases. Additionally, we validated the models by using the resulting fit parameters to predict an independent set of experimental stress-strain curves from ramp-to-failure tests. Overall, the models were both successful in fitting the experiments and predicting the validation data. However, the results did not strongly favor one mechanism over the other. As a result, to distinguish between plastic deformation and damage, different experimental protocols will be needed. Nevertheless, these findings suggest the potential of RIE as a comprehensive framework for studying tendon inelastic behaviors.
Collapse
Affiliation(s)
- Babak Safa
- Department of Mechanical Engineering, Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716
| | - Andrea Lee
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716
| | - Michael H Santare
- ASME Fellow, Department of Mechanical Engineering, Department of Biomedical Engineering, University of Delaware Newark, Delaware 19716
| | - Dawn M Elliott
- ASME Fellow, Department of Biomedical Engineering, Department of Mechanical Engineering, University of Delaware Newark, Delaware 19716
| |
Collapse
|
12
|
Disney CM, Lee PD, Hoyland JA, Sherratt MJ, Bay BK. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo. J Microsc 2018; 272:165-179. [PMID: 29655273 DOI: 10.1111/jmi.12701] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 03/08/2018] [Accepted: 03/16/2018] [Indexed: 12/16/2022]
Abstract
Many biological tissues have a complex hierarchical structure allowing them to function under demanding physiological loading conditions. Structural changes caused by ageing or disease can lead to loss of mechanical function. Therefore, it is necessary to characterise tissue structure to understand normal tissue function and the progression of disease. Ideally intact native tissues should be imaged in 3D and under physiological loading conditions. The current published in situ imaging methodologies demonstrate a compromise between imaging limitations and maintaining the samples native mechanical function. This review gives an overview of in situ imaging techniques used to visualise microstructural deformation of soft tissue, including three case studies of different tissues (tendon, intervertebral disc and artery). Some of the imaging techniques restricted analysis to observational mechanics or discrete strain measurement from invasive markers. Full-field local surface strain measurement has been achieved using digital image correlation. Volumetric strain fields have successfully been quantified from in situ X-ray microtomography (micro-CT) studies of bone using digital volume correlation but not in soft tissue due to low X-ray transmission contrast. With the latest developments in micro-CT showing in-line phase contrast capability to resolve native soft tissue microstructure, there is potential for future soft tissue mechanics research where 3D local strain can be quantified. These methods will provide information on the local 3D micromechanical environment experienced by cells in healthy, aged and diseased tissues. It is hoped that future applications of in situ imaging techniques will impact positively on the design and testing of potential tissue replacements or regenerative therapies. LAY DESCRIPTION: The soft tissues in our bodies, such as tendons, intervertebral discs and arteries, have evolved to have complicated structures which deform and bear load during normal function. Small changes in these structures can occur with age and disease which then leads to loss of function. Therefore, it is important to image tissue microstructure in 3D and under functional conditions. This paper gives an overview of imaging techniques used to record the deformation of soft tissue microstructures. Commonly there are compromises between obtaining the best imaging result and retaining the samples native structure and function. For example, invasive markers and dissecting samples damages the tissues natural structure, and staining or clearing (making the tissue more transparent) can distort tissue structure. Structural deformation has been quantified from 2D imaging techniques (digital image correlation) to create surface strain maps which help identify local tissue mechanics. When extended to 3D (digital volume correlation), deformation measurement has been limited to bone samples using X-ray micro-CT. Recently it has been possible to image the 3D structure of soft tissue using X-ray micro-CT meaning that there is potential for internal soft tissue mechanics to be mapped in 3D. Future application of micro-CT and digital volume correlation will be important for soft tissue mechanics studies particularly to understand normal function, progression of disease and in the design of tissue replacements.
Collapse
Affiliation(s)
- C M Disney
- Centre for Doctoral Training in Regenerative Medicine, University of Manchester, Manchester, U.K.,Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, U.K
| | - P D Lee
- School of Materials, University of Manchester, Manchester, U.K
| | - J A Hoyland
- Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, U.K.,NIHR Manchester Biomedical Research Centre, Manchester Academic Health Science Centre, Central Manchester University Hospitals NHS Foundation Trust, Manchester, U.K
| | - M J Sherratt
- Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, U.K
| | - B K Bay
- School of Mechanical, Industrial and Manufacturing Engineering, Oregon State University, Corvallis, Oregon, U.S.A
| |
Collapse
|
13
|
Moo EK, Sibole SC, Han SK, Herzog W. Three-dimensional micro-scale strain mapping in living biological soft tissues. Acta Biomater 2018; 70:260-269. [PMID: 29425715 DOI: 10.1016/j.actbio.2018.01.048] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2017] [Revised: 01/16/2018] [Accepted: 01/30/2018] [Indexed: 10/18/2022]
Abstract
Non-invasive characterization of the mechanical micro-environment surrounding cells in biological tissues at multiple length scales is important for the understanding of the role of mechanics in regulating the biosynthesis and phenotype of cells. However, there is a lack of imaging methods that allow for characterization of the cell micro-environment in three-dimensional (3D) space. The aims of this study were (i) to develop a multi-photon laser microscopy protocol capable of imprinting 3D grid lines onto living tissue at a high spatial resolution, and (ii) to develop image processing software capable of analyzing the resulting microscopic images and performing high resolution 3D strain analyses. Using articular cartilage as the biological tissue of interest, we present a novel two-photon excitation imaging technique for measuring the internal 3D kinematics in intact cartilage at sub-micrometer resolution, spanning length scales from the tissue to the cell level. Using custom image processing software, we provide accurate and robust 3D micro-strain analysis that allows for detailed qualitative and quantitative assessment of the 3D tissue kinematics. This novel technique preserves tissue structural integrity post-scanning, therefore allowing for multiple strain measurements at different time points in the same specimen. The proposed technique is versatile and opens doors for experimental and theoretical investigations on the relationship between tissue deformation and cell biosynthesis. Studies of this nature may enhance our understanding of the mechanisms underlying cell mechano-transduction, and thus, adaptation and degeneration of soft connective tissues. STATEMENT OF SIGNIFICANCE We presented a novel two-photon excitation imaging technique for measuring the internal 3D kinematics in intact cartilage at sub-micrometer resolution, spanning from tissue length scale to cellular length scale. Using a custom image processing software (lsmgridtrack), we provide accurate and robust micro-strain analysis that allowed for detailed qualitative and quantitative assessment of the 3D tissue kinematics. The approach presented here can also be applied to other biological tissues such as meniscus and annulus fibrosus, as well as tissue-engineered tissues for the characterization of their mechanical properties. This imaging technique opens doors for experimental and theoretical investigation on the relationship between tissue deformation and cell biosynthesis. Studies of this nature may enhance our understanding of the mechanisms underlying cell mechano-transduction, and thus, adaptation and degeneration of soft connective tissues.
Collapse
|
14
|
Sliding enhances fluid and solute transport into buried articular cartilage contacts. Osteoarthritis Cartilage 2017; 25:2100-2107. [PMID: 28888900 DOI: 10.1016/j.joca.2017.08.014] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2017] [Revised: 08/10/2017] [Accepted: 08/30/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Solutes and interstitial water are naturally transported from cartilage by load-induced interstitial fluid pressures. Fluid and solute recovery during joint articulation have been primarily attributed to passive diffusion and mechanical 'pumping' from dynamic loading. This paper tests if the sliding action of articulation is a significant and independent driver of fluid and solute transport in cartilage. DESIGN The large osteochondral samples utilized in the present study preserve the convergent wedges necessary for physiological hydrodynamics. Following static load-induced fluid exudation and prior to sliding, a fluorescent solute (AlexaFluor 633) was added to the lubricant bath. In situ confocal microscopy was used to quantify the transport of solute from the bath into the buried stationary contact area (SCA) during sliding. RESULTS Following static exudation, significant reductions in friction and strain during sliding at 60 mm/s were accompanied by significant solute transport into the inaccessible center of the buried contact; no such transport was detected for the 0- or 1 mm/s sliding conditions. The results suggest that external hydrodynamic pressures from sliding induced advective flows that carried solutes from the bath toward the center of contact. CONCLUSIONS These results provide the first direct evidence that the action of sliding is a significant contributor to fluid and solute recovery by cartilage. Furthermore, they indicate that the sliding-induced transport of solutes into the buried interface was orders of magnitude greater than that attributable to diffusion alone, a result with critical implications for disease prevention and tissue engineering.
Collapse
|
15
|
Lee AH, Elliott DM. Freezing does not alter multiscale tendon mechanics and damage mechanisms in tension. Ann N Y Acad Sci 2017; 1409:85-94. [PMID: 29068534 DOI: 10.1111/nyas.13460] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2017] [Revised: 07/24/2017] [Accepted: 08/02/2017] [Indexed: 12/18/2022]
Abstract
It is common in biomechanics to use previously frozen tissues, where it is assumed that the freeze-thaw process does not cause consequential mechanical or structural changes. We have recently quantified multiscale tendon mechanics and damage mechanisms using previously frozen tissue, where damage was defined as an irreversible change in the microstructure that alters the macroscopic mechanical parameters. Because freezing has been shown to alter tendon microstructures, the objective of this study was to determine if freezing alters tendon multiscale mechanics and damage mechanisms. Multiscale testing using a protocol that was designed to evaluate tendon damage (tensile stress-relaxation followed by unloaded recovery) was performed on fresh and previously frozen rat tail tendon fascicles. At both the fascicle and fibril levels, there was no difference between the fresh and frozen groups for any of the parameters, suggesting that there is no effect of freezing on tendon mechanics. After unloading, the microscale fibril strain fully recovered, and interfibrillar sliding only partially recovered, suggesting that the tendon damage is localized to the interfibrillar structures and that mechanisms of damage are the same in both fresh and previously frozen tendons.
Collapse
Affiliation(s)
- Andrea H Lee
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware
| |
Collapse
|
16
|
Szczesny SE, Fetchko KL, Dodge GR, Elliott DM. Evidence that interfibrillar load transfer in tendon is supported by small diameter fibrils and not extrafibrillar tissue components. J Orthop Res 2017; 35:2127-2134. [PMID: 28071819 PMCID: PMC5503823 DOI: 10.1002/jor.23517] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Accepted: 01/06/2017] [Indexed: 02/06/2023]
Abstract
Collagen fibrils in tendon are believed to be discontinuous and transfer tensile loads through shear forces generated during interfibrillar sliding. However, the structures that transmit these interfibrillar forces are unknown. Various extrafibrillar tissue components (e.g., glycosaminoglycans, collagens XII and XIV) have been suggested to transmit interfibrillar loads by bridging collagen fibrils. Alternatively, collagen fibrils may interact directly through physical fusions and interfibrillar branching. The objective of this study was to test whether extrafibrillar proteins are necessary to transmit load between collagen fibrils or if interfibrillar load transfer is accomplished directly by the fibrils themselves. Trypsin digestions were used to remove a broad spectrum of extrafibrillar proteins and measure their contribution to the multiscale mechanics of rat tail tendon fascicles. Additionally, images obtained from serial block-face scanning electron microscopy were used to determine the three-dimensional fibrillar organization in tendon fascicles and identify any potential interfibrillar interactions. While trypsin successfully removed several extrafibrillar tissue components, there was no change in the macroscale fascicle mechanics or fibril:tissue strain ratio. Furthermore, the imaging data suggested that a network of smaller diameter fibrils (<150 nm) wind around and fuse with their neighboring larger diameter fibrils. These findings demonstrate that interfibrillar load transfer is not supported by extrafibrillar tissue components and support the hypothesis that collagen fibrils are capable of transmitting loads themselves. Conclusively determining how fibrils bear load within tendon is critical for identifying the mechanisms that impair tissue function with degeneration and for restoring tissue properties via cell-mediated regeneration or engineered tissue replacements. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2127-2134, 2017.
Collapse
Affiliation(s)
- Spencer E. Szczesny
- Department of Bioengineering, University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104
| | - Kristen L. Fetchko
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE 19716
| | - George R. Dodge
- Department of Orthopaedic Surgery, University of Pennsylvania, 424 Stemmler Hall, 36 St & Hamilton Walk, Philadelphia, PA 19104,Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz Veterans Affairs Medical Center, 3900 Woodland Ave, Philadelphia, PA 19104
| | - Dawn M. Elliott
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE 19716,Corresponding Author: Dawn M. Elliott, Ph.D., 161 Colburn Lab, 150 Academy Street, Newark, DE 19716, Phone: 302-831-1295,
| |
Collapse
|
17
|
Lee AH, Szczesny SE, Santare MH, Elliott DM. Investigating mechanisms of tendon damage by measuring multi-scale recovery following tensile loading. Acta Biomater 2017; 57:363-372. [PMID: 28435080 PMCID: PMC6688648 DOI: 10.1016/j.actbio.2017.04.011] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2016] [Revised: 04/07/2017] [Accepted: 04/11/2017] [Indexed: 01/28/2023]
Abstract
Tendon pathology is associated with damage. While tendon damage is likely initiated by mechanical loading, little is known about the specific etiology. Damage is defined as an irreversible change in the microstructure that alters the macroscopic mechanical parameters. In tendon, the link between mechanical loading and microstructural damage, resulting in macroscopic changes, is not fully elucidated. In addition, tendon damage at the macroscale has been proposed to initiate when tendon is loaded beyond a strain threshold, yet the metrics to define the damage threshold are not determined. We conducted multi-scale mechanical testing to investigate the mechanism of tendon damage by simultaneously quantifying macroscale mechanical and microstructural changes. At the microscale, we observe full recovery of the fibril strain and only partial recovery of the interfibrillar sliding, indicating that the damage initiates at the interfibrillar structures. We show that non-recoverable sliding is a mechanism for tendon damage and is responsible for the macroscale decreased linear modulus and elongated toe-region observed at the fascicle-level, and these macroscale properties are appropriate metrics that reflect tendon damage. We concluded that the inflection point of the stress-strain curve represents the damage threshold and, therefore, may be a useful parameter for future studies. Establishing the mechanism of damage at multiple length scales can improve prevention and rehabilitation strategies for tendon pathology. STATEMENT OF SIGNIFICANCE Tendon pathology is associated with mechanically induced damage. Damage, as defined in engineering, is an irreversible change in microstructure that alters the macroscopic mechanical properties. Although microstructural damage and changes to macroscale mechanics are likely, this link to microstructural change was not yet established. We conducted multiscale mechanical testing to investigate the mechanism of tendon damage by simultaneously quantifying macroscale mechanical and microstructural changes. We showed that non-recoverable sliding between collagen fibrils is a mechanism for tendon damage. Establishing the mechanism of damage at multiple length scales can improve prevention and rehabilitation strategies for tendon pathology.
Collapse
Affiliation(s)
- Andrea H Lee
- Department of Biomedical Engineering, University of Delaware, United States
| | - Spencer E Szczesny
- Department of Orthopaedic Surgery, University of Pennsylvania, United States
| | - Michael H Santare
- Department of Mechanical Engineering, University of Delaware, United States
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, United States.
| |
Collapse
|
18
|
Exposure to buffer solution alters tendon hydration and mechanics. J Biomech 2017; 61:18-25. [PMID: 28720201 DOI: 10.1016/j.jbiomech.2017.06.045] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 06/20/2017] [Accepted: 06/29/2017] [Indexed: 11/22/2022]
Abstract
A buffer solution is often used to maintain tissue hydration during mechanical testing. The most commonly used buffer solution is a physiological concentration of phosphate buffered saline (PBS); however, PBS increases the tissue's water content and decreases its tensile stiffness. In addition, solutes from the buffer can diffuse into the tissue and interact with its structure and mechanics. These bathing solution effects can confound the outcome and interpretation of mechanical tests. Potential bathing solution artifacts, including solute diffusion, and their effect on mechanical properties, are not well understood. The objective of this study was to measure the effects of long-term exposure of rat tail tendon fascicles to several concentrations (0.9-25%) of NaCl, sucrose, polyethylene glycol (PEG), and SPEG (NaCl+PEG) solutions on water content, solute diffusion, and mechanical properties. We found that with an increase in solute concentration the apparent water content decreased for all solution types. Solutes diffused into the tissue for NaCl and sucrose, however, no solute diffusion was observed for PEG or SPEG. The mechanical properties changed for both NaCl solutions, in particular after long-term (8h) incubation the modulus and equilibrium stress decreased compared to short-term (15min) for 25% NaCl, and the cross sectional area increased for 0.9% NaCl. However, the mechanical properties were unchanged for both PEG and SPEG except for minor alterations in stress relaxation parameters. This study shows that NaCl and sucrose buffer solutions are not suitable for long-term mechanical tests. We therefore propose using PEG or SPEG as alternative buffer solutions that after long-term incubation can maintain tissue hydration without solute diffusion and produce a consistent mechanical response.
Collapse
|
19
|
Fang F, Lake SP. Experimental evaluation of multiscale tendon mechanics. J Orthop Res 2017; 35:1353-1365. [PMID: 27878999 DOI: 10.1002/jor.23488] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 11/16/2016] [Indexed: 02/04/2023]
Abstract
Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| | - Spencer P Lake
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Orthopaedic Surgery, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| |
Collapse
|
20
|
Advanced glycation end-products: Mechanics of aged collagen from molecule to tissue. Matrix Biol 2016; 59:95-108. [PMID: 27616134 DOI: 10.1016/j.matbio.2016.09.001] [Citation(s) in RCA: 160] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 08/29/2016] [Accepted: 09/01/2016] [Indexed: 01/03/2023]
Abstract
Concurrent with a progressive loss of regenerative capacity, connective tissue aging is characterized by a progressive accumulation of Advanced Glycation End-products (AGEs). Besides being part of the typical aging process, type II diabetics are particularly affected by AGE accumulation due to abnormally high levels of systemic glucose that increases the glycation rate of long-lived proteins such as collagen. Although AGEs are associated with a wide range of clinical disorders, the mechanisms by which AGEs contribute to connective tissue disease in aging and diabetes are still poorly understood. The present study harnesses advanced multiscale imaging techniques to characterize a widely employed in vitro model of ribose induced collagen aging and further benchmarks these data against experiments on native human tissues from donors of different age. These efforts yield unprecedented insight into the mechanical changes in collagen tissues across hierarchical scales from molecular, to fiber, to tissue-levels. We observed a linear increase in molecular spacing (from 1.45nm to 1.5nm) and a decrease in the D-period length (from 67.5nm to 67.1nm) in aged tissues, both using the ribose model of in vitro glycation and in native human probes. Multiscale mechanical analysis of in vitro glycated tendons strongly suggests that AGEs reduce tissue viscoelasticity by severely limiting fiber-fiber and fibril-fibril sliding. This study lays an important foundation for interpreting the functional and biological effects of AGEs in collagen connective tissues, by exploiting experimental models of AGEs crosslinking and benchmarking them for the first time against endogenous AGEs in native tissue.
Collapse
|
21
|
Fang F, Lake SP. Multiscale mechanical integrity of human supraspinatus tendon in shear after elastin depletion. J Mech Behav Biomed Mater 2016; 63:443-455. [PMID: 27472764 DOI: 10.1016/j.jmbbm.2016.06.032] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 06/27/2016] [Accepted: 06/30/2016] [Indexed: 01/28/2023]
Abstract
Human supraspinatus tendon (SST) exhibits region-specific nonlinear mechanical properties under tension, which have been attributed to its complex multiaxial physiological loading environment. However, the mechanical response and underlying multiscale mechanism regulating SST behavior under other loading scenarios are poorly understood. Furthermore, little is known about the contribution of elastin to tendon mechanics. We hypothesized that (1) SST exhibits region-specific shear mechanical properties, (2) fiber sliding is the predominant mode of local matrix deformation in SST in shear, and (3) elastin helps maintain SST mechanical integrity by facilitating force transfer among collagen fibers. Through the use of biomechanical testing and multiphoton microscopy, we measured the multiscale mechanical behavior of human SST in shear before and after elastase treatment. Three distinct SST regions showed similar stresses and microscale deformation. Collagen fiber reorganization and sliding were physical mechanisms observed as the SST response to shear loading. Measures of microscale deformation were highly variable, likely due to a high degree of extracellular matrix heterogeneity. After elastase treatment, tendon exhibited significantly decreased stresses under shear loading, particularly at low strains. These results show that elastin contributes to tendon mechanics in shear, further complementing our understanding of multiscale tendon structure-function relationships.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering & Materials Science, Washington University in St. Louis, United States
| | - Spencer P Lake
- Department of Mechanical Engineering & Materials Science, Washington University in St. Louis, United States; Department of Biomedical Engineering, Washington University in St. Louis, United States; Department of Orthopaedic Surgery, Washington University in St. Louis, United States.
| |
Collapse
|
22
|
Fang F, Lake SP. Multiscale strain analysis of tendon subjected to shear and compression demonstrates strain attenuation, fiber sliding, and reorganization. J Orthop Res 2015; 33:1704-12. [PMID: 26036894 DOI: 10.1002/jor.22955] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 05/21/2015] [Indexed: 02/04/2023]
Abstract
The manner in which strains are passed down the hierarchical length scales of tendons dictates how cells within the collagen network regulate the tissue response to loading. How tendons deform in different hierarchical levels under shear and compression is unknown. The aims of this study were: (i) to evaluate whether specific regions of bovine deep digital flexor tendons exhibited different strain attenuation from macro to micro length scales, and (ii) to elucidate mechanisms responsible for tendon deformation under shear and compression. Samples from distal and proximal regions of flexor tendons were subjected to three-step incremental stress-relaxation tests. Images of tissue markers, photobleached lines on collagen fibers, and nuclei locations were collected before and after loading. Results showed that strain transfer was attenuated from tissue to local matrix under both shear and compression. Nuclear aspect ratios exhibited smaller changes for distal samples, suggesting that cells are more shielded from deformation in the distal region. Collagen fiber sliding was observed to contribute significantly in response to shear, while uncrimping and fiber reorganization were the predominant mechanisms under compression. This study provides insight into microscale mechanisms responsible for multiscale strain attenuation of tendons under non-tensile macroscale loading.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, Missouri
| | - Spencer P Lake
- Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, Missouri.,Department of Biomedical Engineering, Washington University, St. Louis, Missouri.,Department of Orthopaedic Surgery, Washington University, St. Louis, Missouri
| |
Collapse
|
23
|
Szczesny SE, Caplan JL, Pedersen P, Elliott DM. Quantification of Interfibrillar Shear Stress in Aligned Soft Collagenous Tissues via Notch Tension Testing. Sci Rep 2015; 5:14649. [PMID: 26469396 PMCID: PMC4606738 DOI: 10.1038/srep14649] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Accepted: 09/02/2015] [Indexed: 11/29/2022] Open
Abstract
The mechanical function of soft collagenous tissues is largely determined by their hierarchical organization of collagen molecules. While collagen fibrils are believed to be discontinuous and transfer load through shearing of the interfibrillar matrix, interfibrillar shear stresses have never been quantified. Scaling traditional shear testing procedures down to the fibrillar length scale is impractical and would introduce substantial artifacts. Here, through the use of a novel microscopic variation of notch tension testing, we explicitly demonstrate the existence of interfibrillar shear stresses within tendon fascicles and provide the first measurement of their magnitude. Axial stress gradients along the sample length generated by notch tension testing were measured and used to calculate a value of 32 kPa for the interfibrillar shear stress. This estimate is comparable to the interfibrillar shear stress predicted by previous multiscale modeling of tendon fascicles, which supports the hypothesis that fibrils are discontinuous and transmit load through interfibrillar shear. This information regarding the structure-function relationships of tendon and other soft collagenous tissues is necessary to identify potential causes for tissue impairment with degeneration and provide the foundation for developing regenerative repair strategies or engineering biomaterials for tissue replacement.
Collapse
Affiliation(s)
- Spencer E Szczesny
- Department of Bioengineering. University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104
| | - Jeffrey L Caplan
- Delaware Biotechnology Institute, 15 Innovation Way, Suite 117, Newark, DE 19716
| | - Pal Pedersen
- Carl Zeiss Microscopy, One Zeiss Drive, Thornwood, NY 10594
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, 161 Colburn Lab, 150 Academy Street, Newark, DE 19716
| |
Collapse
|
24
|
Szczesny SE, Elliott DM. Incorporating plasticity of the interfibrillar matrix in shear lag models is necessary to replicate the multiscale mechanics of tendon fascicles. J Mech Behav Biomed Mater 2014; 40:325-338. [PMID: 25262202 DOI: 10.1016/j.jmbbm.2014.09.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 08/26/2014] [Accepted: 09/02/2014] [Indexed: 11/18/2022]
Abstract
Despite current knowledge of tendon structure, the fundamental deformation mechanisms underlying tendon mechanics and failure are unknown. We recently showed that a shear lag model, which explicitly assumed plastic interfibrillar load transfer between discontinuous fibrils, could explain the multiscale fascicle mechanics, suggesting that fascicle yielding is due to plastic deformation of the interfibrillar matrix. However, it is unclear whether alternative physical mechanisms, such as elastic interfibrillar deformation or fibril yielding, also contribute to fascicle mechanical behavior. The objective of the current work was to determine if plasticity of the interfibrillar matrix is uniquely capable of explaining the multiscale mechanics of tendon fascicles including the tissue post-yield behavior. This was examined by comparing the predictions of a continuous fibril model and three separate shear lag models incorporating an elastic, plastic, or elastoplastic interfibrillar matrix with multiscale experimental data. The predicted effects of fibril yielding on each of these models were also considered. The results demonstrated that neither the continuous fibril model nor the elastic shear lag model can successfully predict the experimental data, even if fibril yielding is included. Only the plastic or elastoplastic shear lag models were capable of reproducing the multiscale tendon fascicle mechanics. Differences between these two models were small, although the elastoplastic model did improve the fit of the experimental data at low applied tissue strains. These findings suggest that while interfibrillar elasticity contributes to the initial stress response, plastic deformation of the interfibrillar matrix is responsible for tendon fascicle post-yield behavior. This information sheds light on the physical processes underlying tendon failure, which is essential to improve our understanding of tissue pathology and guide the development of successful repair.
Collapse
Affiliation(s)
- Spencer E Szczesny
- Department of Bioengineering, University of Pennsylvania, 240 Skirkanich Hall, 210 South 33rd St, Philadelphia, PA 19104, United States.
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, 125 East Delaware Avenue, Newark, DE 19716, United States.
| |
Collapse
|