1
|
Park DS, Na MH, Jeong MH, Sim DS, Jin YJ, Kee HJ, Kim MK, Kim JH, Hong YJ, Cho KH, Hyun DY, Oh S, Lim KS, Byeon DH, Kim JH. Efficacy and Safety Evaluation of Tacrolimus-Eluting Stent in a Porcine Coronary Artery Model. Tissue Eng Regen Med 2024; 21:723-735. [PMID: 38834902 PMCID: PMC11187055 DOI: 10.1007/s13770-024-00646-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 03/16/2024] [Accepted: 04/21/2024] [Indexed: 06/06/2024] Open
Abstract
BACKGROUND A drug-eluting stent (DES) is a highly beneficial medical device used to widen or unblock narrowed blood vessels. However, the drugs released by the implantation of DES may hinder the re-endothelialization process, increasing the risk of late thrombosis. We have developed a tacrolimus-eluting stent (TES) that as acts as a potent antiproliferative and immunosuppressive agent, enhancing endothelial regeneration. In addition, we assessed the safety and efficacy of TES through both in vitro and in vivo tests. METHODS Tacrolimus and Poly(lactic-co-glycolic acid) (PLGA) were applied to the metal stent using electrospinning equipment. The surface morphology of the stent was examined before and after coating using a scanning electron microscope (SEM) and energy dispersive X-rays (EDX). The drug release test was conducted through high-performance liquid chromatography (HPLC). Cell proliferation and migration assays were performed using smooth muscle cells (SMC). The stent was then inserted into the porcine coronary artery and monitored for a duration of 4 weeks. RESULTS SEM analysis confirmed that the coating surface was uniform. Furthermore, EDX analysis showed that the surface was coated with both polymer and drug components. The HPCL analysis of TCL at a wavelength of 215 nm revealed that the drug was continuously released over a period of 4 weeks. Smooth muscle cell migration was significantly decreased in the tacrolimus group (54.1% ± 11.90%) compared to the non-treated group (90.1% ± 4.86%). In animal experiments, the stenosis rate was significantly reduced in the TES group (29.6% ± 7.93%) compared to the bare metal stent group (41.3% ± 10.18%). Additionally, the fibrin score was found to be lower in the TES group compared to the group treated with a sirolimus-eluting stent (SES). CONCLUSION Similar to SES, TES reduces neointimal proliferation in a porcine coronary artery model, specifically decreasing the fibrins score. Therefore, tacrolimus could be considered a promising drug for reducing restenosis and thrombosis.
Collapse
Affiliation(s)
- Dae Sung Park
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
- The Research Institute of Medical Sciences, Chonnam National University, Gwangju, Korea
| | - Mi Hyang Na
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
| | - Myung Ho Jeong
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea.
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea.
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea.
- Department of Cardiovascular Medicine, Chonnam National University Medical School, Gwangju, Korea.
- Department of Cardiovascular Center, Gwangju Veterans Hospital, Gwangju, Korea.
| | - Doo Sun Sim
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea.
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea.
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea.
- Department of Cardiovascular Medicine, Chonnam National University Medical School, Gwangju, Korea.
| | - Yu Jeong Jin
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
| | - Hae Jin Kee
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
| | - Mun Ki Kim
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
| | - Jeong Ha Kim
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
| | - Young Joon Hong
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
- Department of Cardiovascular Medicine, Chonnam National University Medical School, Gwangju, Korea
| | - Kyung Hoon Cho
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
- Department of Cardiovascular Medicine, Chonnam National University Medical School, Gwangju, Korea
| | - Dae Young Hyun
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Seok Oh
- The Korea Cardiovascular Stent Research Institute, Chonnam National University, Gwangju, Korea
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea Ministry of Health and Welfare, Gwangju, Korea
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Kyung Seob Lim
- Futuristic Animal Resource & Research Center, Korea Research Institute of Bioscience and Biotechnology, Ochang, Korea
| | | | - Jeong Hun Kim
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
| |
Collapse
|
2
|
de Oliveira Laterza Ribeiro M, Correia VM, Herling de Oliveira LL, Soares PR, Scudeler TL. Evolving Diagnostic and Management Advances in Coronary Heart Disease. Life (Basel) 2023; 13:951. [PMID: 37109480 PMCID: PMC10143565 DOI: 10.3390/life13040951] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 04/02/2023] [Accepted: 04/03/2023] [Indexed: 04/29/2023] Open
Abstract
Despite considerable improvement in diagnostic modalities and therapeutic options over the last few decades, the global burden of ischemic heart disease is steadily rising, remaining a major cause of death worldwide. Thus, new strategies are needed to lessen cardiovascular events. Researchers in different areas such as biotechnology and tissue engineering have developed novel therapeutic strategies such as stem cells, nanotechnology, and robotic surgery, among others (3D printing and drugs). In addition, advances in bioengineering have led to the emergence of new diagnostic and prognostic techniques, such as quantitative flow ratio (QFR), and biomarkers for atherosclerosis. In this review, we explore novel diagnostic invasive and noninvasive modalities that allow a more detailed characterization of coronary disease. We delve into new technological revascularization procedures and pharmacological agents that target several residual cardiovascular risks, including inflammatory, thrombotic, and metabolic pathways.
Collapse
Affiliation(s)
| | | | | | | | - Thiago Luis Scudeler
- Instituto do Coração (InCor), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo 05403-010, Brazil
| |
Collapse
|
3
|
Koźlik M, Harpula J, Chuchra PJ, Nowak M, Wojakowski W, Gąsior P. Drug-Eluting Stents: Technical and Clinical Progress. Biomimetics (Basel) 2023; 8:biomimetics8010072. [PMID: 36810403 PMCID: PMC9944483 DOI: 10.3390/biomimetics8010072] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 02/02/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023] Open
Abstract
Drug-eluting stents (DES) demonstrated superior efficacy when compared to bare metal stents and plain-old balloon angioplasty and are nowadays used in almost all percutaneous revascularization procedures. The design of the stent platforms is constantly improving to maximize its efficacy and safety. Constant development of DES includes adoption of new materials used for scaffold production, new design types, improved overexpansion abilities, new polymers coating and, finally, improved antiproliferative agents. Especially nowadays, with the immense number of available DES platforms, it is crucial to understand how different aspects of stents impact the effect of their implantation, as subtle differences between various stent platforms could impact the most important issue-clinical outcomes. This review discusses the current status of coronary stents and the impact of stent material, strut design and coating techniques on cardiovascular outcomes.
Collapse
Affiliation(s)
- Maciej Koźlik
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
- Correspondence:
| | - Jan Harpula
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
| | - Piotr J. Chuchra
- Students’ Scientific Society, Department of Cardiology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Magdalena Nowak
- Students’ Scientific Society, Department of Cardiology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
| | - Wojciech Wojakowski
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
| | - Paweł Gąsior
- Division of Cardiology and Structural Heart Disease, Medical University of Silesia, 40-635 Katowice, Poland
| |
Collapse
|
4
|
Shazly T, Torres WM, Secemsky EA, Chitalia VC, Jaffer FA, Kolachalama VB. Understudied factors in drug-coated balloon design and evaluation: A biophysical perspective. Bioeng Transl Med 2023; 8:e10370. [PMID: 36684110 PMCID: PMC9842065 DOI: 10.1002/btm2.10370] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 05/28/2022] [Accepted: 06/12/2022] [Indexed: 01/25/2023] Open
Abstract
Drug-coated balloon (DCB) percutaneous interventional therapy allows for durable reopening of the narrowed lumen via physical tissue expansion and local anti-restenosis drug delivery, providing an alternative to traditional uncoated balloons or a permanent indwelling implant such as a conventional metallic drug-eluting stent. While DCB-based treatment of peripheral arterial disease (PAD) has been incorporated into clinical guidelines, DCB use has been recently curtailed due to reports that showed evidence of increased mortality risk in patients treated with paclitaxel (PTX)-coated balloons. Given the United States Food and Drug Administration's 2019 consequent warning regarding PTX-eluting DCBs and the subsequent marked reduction in clinical DCB use, there is now a critical need to better understand the compositional and mechanical factors underlying DCB efficacy and safety. Most work to date on DCB refinement has focused on designing both the enabling balloon catheter and alternate coatings composed of various drugs and excipients, followed by device evaluation in preclinical and clinical studies. We contend that improvement in DCB performance will require a better understanding of the biophysical factors operative during and following balloon deployment, and moreover that the elaboration and demonstrated control of these factors are needed to address current concerns with DCB use. This article provides a perspective on the biophysical interactions that govern DCB performance and offers new design strategies for the development of next-generation DCB devices.
Collapse
Affiliation(s)
- Tarek Shazly
- College of Engineering & ComputingUniversity of South CarolinaColumbiaSouth CarolinaUSA
| | - William M. Torres
- College of Engineering & ComputingUniversity of South CarolinaColumbiaSouth CarolinaUSA
- Exponent Inc.PhiladelphiaPennsylvaniaUSA
| | - Eric A. Secemsky
- Smith Center for Outcomes Research in CardiologyBeth Israel Deaconess Medical CenterBostonMassachusettsUSA
| | - Vipul C. Chitalia
- Department of Medicine, Boston University School of MedicineBoston Veterans Affairs Healthcare SystemBostonMassachusettsUSA
| | - Farouc A. Jaffer
- Cardiovascular Research Center and Cardiology DivisionMassachusetts General HospitalBostonMassachusettsUSA
| | - Vijaya B. Kolachalama
- Department of Medicine, Boston University School of Medicine; Department of Computer Science and Faculty of Computing & Data SciencesBoston UniversityBostonMassachusettsUSA
| |
Collapse
|
5
|
Salvi S, Jain A, Pontrelli G, McGinty S. Modeling Dual Drug Delivery from Eluting Stents: The Influence of Non-Linear Binding Competition and Non-Uniform Drug Loading. Pharm Res 2023; 40:215-230. [PMID: 36473984 DOI: 10.1007/s11095-022-03419-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Accepted: 10/15/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVE There is increasing interest in simultaneous endovascular delivery of more than one drug from a drug-loaded stent into a diseased artery. There may be an opportunity to obtain a therapeutically desirable uptake profile of the two drugs over time by appropriate design of the initial drug distribution in the stent. Due to the non-linear, coupled nature of diffusion and reversible specific/non-specific binding of both drugs as well as competition between the drugs for a fixed binding site density, a comprehensive numerical investigation of this problem is critically needed. METHODS This paper presents numerical computation of dual drug delivery in a stent-artery system, accounting for diffusion as well as specific and non-specific reversible binding. The governing differential equations are discretized in space, followed by integration over time using a stiff numerical solver. Three different cases of initial dual drug distribution are considered. RESULTS For the particular case of sirolimus and paclitaxel, results show that competition for a limited non-specific binding site density and the significant difference in the forward/backward reaction coefficients play a key role in determining the nature of drug uptake. The nature of initial distribution of the two drugs in the stent is also found to influence the binding process, which can potentially be used to engineer a desirable dual drug uptake profile. CONCLUSIONS These results help improve the fundamental understanding of endovascular dual drug delivery. In addition, the numerical technique and results presented here may be helpful for designing and optimizing other drug delivery problems as well.
Collapse
Affiliation(s)
- Swapnil Salvi
- Mechanical and Aerospace Engineering Department, University of Texas at Arlington, 500 W First St, Rm 211, Arlington, TX, 76019, USA
| | - Ankur Jain
- Mechanical and Aerospace Engineering Department, University of Texas at Arlington, 500 W First St, Rm 211, Arlington, TX, 76019, USA.
| | - Giuseppe Pontrelli
- Istituto per le Applicazioni del Calcolo - CNR, Via dei Taurini 19, 00185, Rome, Italy
| | - Sean McGinty
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK.,Glasgow Computational Engineering Centre, University of Glasgow, Glasgow, UK
| |
Collapse
|
6
|
McQueen A, Escuer J, Schmidt AF, Aggarwal A, Kennedy S, McCormick C, Oldroyd K, McGinty S. An intricate interplay between stent drug dose and release rate dictates arterial restenosis. J Control Release 2022; 349:992-1008. [PMID: 35921913 DOI: 10.1016/j.jconrel.2022.07.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 07/14/2022] [Accepted: 07/26/2022] [Indexed: 10/15/2022]
Abstract
Since the introduction of percutaneous coronary intervention (PCI) for the treatment of obstructive coronary artery disease (CAD), patient outcomes have progressively improved. Drug eluting stents (DES) that employ anti-proliferative drugs to limit excess tissue growth following stent deployment have proved revolutionary. However, restenosis and a need for repeat revascularisation still occurs after DES use. Over the last few years, computational models have emerged that detail restenosis following the deployment of a bare metal stent (BMS), focusing primarily on contributions from mechanics and fluid dynamics. However, none of the existing models adequately account for spatiotemporal delivery of drug and the influence of this on the cellular processes that drive restenosis. In an attempt to fill this void, a novel continuum restenosis model coupled with spatiotemporal drug delivery is presented. Our results indicate that the severity and time-course of restenosis is critically dependent on the drug delivery strategy. Specifically, we uncover an intricate interplay between initial drug loading, drug release rate and restenosis, indicating that it is not sufficient to simply ramp-up the drug dose or prolong the time course of drug release to improve stent efficacy. Our model also shows that the level of stent over-expansion and stent design features, such as inter-strut spacing and strut thickness, influence restenosis development, in agreement with trends observed in experimental and clinical studies. Moreover, other critical aspects of the model which dictate restenosis, including the drug binding site density are investigated, where comparisons are made between approaches which assume this to be either constant or proportional to the number of smooth muscle cells (SMCs). Taken together, our results highlight the necessity of incorporating these aspects of drug delivery in the pursuit of optimal DES design.
Collapse
Affiliation(s)
- Alistair McQueen
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK
| | - Javier Escuer
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
| | | | - Ankush Aggarwal
- Glasgow Computational Engineering Centre, Division of Infrastructure and Environment, University of Glasgow, Glasgow, UK
| | - Simon Kennedy
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK
| | | | - Keith Oldroyd
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK
| | - Sean McGinty
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK; Glasgow Computational Engineering Centre, Division of Infrastructure and Environment, University of Glasgow, Glasgow, UK.
| |
Collapse
|
7
|
Abbasnezhad N, Zirak N, Champmartin S, Shirinbayan M, Bakir F. An Overview of In Vitro Drug Release Methods for Drug-Eluting Stents. Polymers (Basel) 2022; 14:2751. [PMID: 35808798 PMCID: PMC9269075 DOI: 10.3390/polym14132751] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 06/15/2022] [Accepted: 06/16/2022] [Indexed: 01/08/2023] Open
Abstract
The drug release profile of drug-eluting stents (DESs) is affected by a number of factors, including the formulation, design, and physicochemical properties of the utilized material. DES has been around for twenty years and despite its widespread clinical use, and efficacy in lowering the rate of target lesion restenosis, it still requires additional development to reduce side effects and provide long-term clinical stability. Unfortunately, for analyzing these implants, there is still no globally accepted in vitro test method. This is owing to the stent's complexity as well as the dynamic arterial compartments of the blood and vascular wall. The former is the source of numerous biological, chemical, and physical mechanisms that are more commonly observed in tissue, lumen, and DES. As a result, universalizing bio-relevant apparatus, suitable for liberation testing of such complex implants is difficult. This article aims to provide a comprehensive review of the methods used for in vitro release testing of DESs. Aspects related to the correlation of the release profiles in the cases of in vitro and in vivo are also addressed.
Collapse
Affiliation(s)
- Navideh Abbasnezhad
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
- Arts et Métiers Institute of Technology, CNAM, PIMM, HESAM University, F-75013 Paris, France;
| | - Nader Zirak
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
- Arts et Métiers Institute of Technology, CNAM, PIMM, HESAM University, F-75013 Paris, France;
| | - Stéphane Champmartin
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
| | - Mohammadali Shirinbayan
- Arts et Métiers Institute of Technology, CNAM, PIMM, HESAM University, F-75013 Paris, France;
| | - Farid Bakir
- Arts et Métiers Institute of Technology, CNAM, LIFSE, HESAM University, F-75013 Paris, France; (N.Z.); (S.C.)
| |
Collapse
|
8
|
Nicolas J, Pivato CA, Chiarito M, Beerkens F, Cao D, Mehran R. Evolution of drug-eluting coronary stents: a back-and-forth journey from the bench-to-bedside. Cardiovasc Res 2022; 119:631-646. [PMID: 35788828 DOI: 10.1093/cvr/cvac105] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 05/06/2022] [Accepted: 05/11/2022] [Indexed: 11/13/2022] Open
Abstract
Coronary stents have revolutionized the treatment of coronary artery disease. Compared with balloon angioplasty, bare-metal stents effectively prevented abrupt vessel closure but were limited by in-stent restenosis due to smooth muscle cell proliferation and neointimal hyperplasia. The first-generation drug-eluting stent (DES), with its antiproliferative drug coating, offered substantial advantages over bare-metal stents as it mitigated the risk of in-stent restenosis. Nonetheless, they had several design limitations that increased the risk of late stent thrombosis. Significant advances in stent design, including thinner struts, enhanced polymers' formulation, and more potent antiproliferative agents, have led to the introduction of new-generation DES with a superior safety profile. Cardiologists have over 20 different DES types to choose from, each with its unique features and characteristics. This review highlights the evolution of stent design and summarizes the clinical data on the different stent types. We conclude by discussing the clinical implications of stent design in high-risk subsets of patients.
Collapse
Affiliation(s)
- Johny Nicolas
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Carlo Andrea Pivato
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.,IRCCS Humanitas Research Hospital, via Manzoni 56, 20089 Rozzano, Milan, Italy
| | - Mauro Chiarito
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Department of Biomedical Sciences, Humanitas University, Pieve Emanuele-Milan, Italy.,IRCCS Humanitas Research Hospital, via Manzoni 56, 20089 Rozzano, Milan, Italy
| | - Frans Beerkens
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Davide Cao
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.,Cardiovascular Department, Humanitas Gavazzeni, Bergamo, Italy
| | - Roxana Mehran
- The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| |
Collapse
|
9
|
Ali J, Rha SW, Choi BG, Byun JK, Choi SY, Cha JA, Park S, Lee K, Back S, Lee J, Kang DO, Choi JY, Roh SY, Na JO, Choi CU, Kim JW, Kim EJ, Park CG, Seo HS, Wasim M, Hassan Z. Impact of Drug-Eluting Stent-associated Coronary Artery Spasm on 3-Year Clinical Outcomes: A Propensity Score Matching Analysis. Indian Heart J 2022; 74:182-186. [PMID: 35576993 PMCID: PMC9243619 DOI: 10.1016/j.ihj.2022.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 04/26/2022] [Accepted: 05/08/2022] [Indexed: 11/17/2022] Open
Abstract
Background It has been reported that significant endothelial dysfunction or clinically evident vasospasm can be associated with drug-eluting stents (DESs). However, the impact of DES associated coronary artery spasm (CAS) on long-term clinical outcomes has not been fully elucidated as compared with those of patients with vasospastic angina. Methods A total of 2797 consecutive patients without significant coronary artery lesion (<70%), who underwent the Acetylcholine (Ach) provocation test, were enrolled between Nov 2004 and Oct 2010. DES-associated spasm was defined as significant CAS in proximal or distal to previously implanted DES site at follow-up angiography with Ach test. Patients were divided into two groups (DES-CAS; n = 108, CAS; n = 1878). For adjustment, propensity score matching (PSM) was done (C-statistics = 0.766, DES-CAS; n = 102, CAS; n = 102). SPSS 20 (Inc., Chicago, Illinois) was used to analyze this data. Results Baseline characteristics were worse in the DES-CAS group. After PSM, both baseline characteristics and the Ach test results were balanced except higher incidence of diffuse CAS and ECG change in the DES-CAS group. During Ach test, the incidence of diffuse spasm (93.1% vs. 81.3%, p = 0.012) and ST-T change (10.7% vs. 1.9%, p = 0.010) were higher in the DES-CAS group. At 3-year, before and after adjustment, the DES-CAS group showed a higher incidence of coronary revascularization (9.8% vs. 0.0%, p = 0.001), recurrent chest pain requiring follow up coronary angiography (CAG, 24.5% vs. 7.8%, p = 0.001) and major adverse cardiac events (MACEs, 9.8% vs. 0.9%, p < 0.005). Conclusion In this study, DES associated CAS was associated with higher incidence of diffuse spasm, ST-T change and adverse 3-year clinical outcomes. Special caution should be exercised in this particular subset of patients.
Collapse
|
10
|
Escuer J, Schmidt AF, Peña E, Martínez MA, McGinty S. Mathematical modelling of endovascular drug delivery: balloons versus stents. Int J Pharm 2022; 620:121742. [DOI: 10.1016/j.ijpharm.2022.121742] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Revised: 04/03/2022] [Accepted: 04/08/2022] [Indexed: 01/15/2023]
|
11
|
Hemodynamic Impact of Stenting on Carotid Bifurcation: A Potential Role of the Stented Segment and External Carotid Artery. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2021; 2021:7604532. [PMID: 34868344 PMCID: PMC8642019 DOI: 10.1155/2021/7604532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 10/26/2021] [Accepted: 11/05/2021] [Indexed: 11/30/2022]
Abstract
Carotid stenting near the bifurcation carina is associated with adverse events, especially in-stent restenosis, thrombosis, and side branch occlusion in clinical data. This study is aimed at determining the potential biomechanical mechanisms for these adverse events after carotid stenting. The patient-specific carotid models were constructed with different stenting scenarios to study the flow distribution and hemodynamic parameters, such as wall shear stress (WSS), flow velocity, relative residence time (RRT), and oscillating shear index (OSI) in the carotid bifurcation. The results suggested that the existing stents surely reduced blood flow to the external carotid artery (ECA) but enhanced local flow disturbance both in ECA and stented internal carotid artery (ICA), and the inner posterior wall of the stented ICA and the outer posterior wall of ECA might endure a relatively low level of WSS and remarkably elevated OSI and RRT. In addition, the implanted stent leads to more ECA adverse flow than ICA after stenting. While disturbed flow near the strut increased as stent length increased, blood flow and areas of local flow disturbance in ECA slightly decreased as stent length increased. In conclusion, the results revealed that ECA might be in relatively high levels of abnormal local hemodynamics after stenting, followed by stented ICA, leading to potential adverse events after intervention.
Collapse
|
12
|
Biswas S, Sarifuddin, Mandal PK. An unsteady analysis of two-phase binding of drug in an asymmetric stenosed vessel. Biomed Phys Eng Express 2021. [DOI: 10.1088/2057-1976/ac3d9b] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Abstract
In this paper, we investigate endovascular delivery to get a step ahead of the pharmacological limitations it has due to the complexity of dealing with a patient-specific vessel through a mathematical model. We divide the domain of computation into four sub-domains: the lumen, the lumen-tissue interface, the upper tissue and the lower tissue which are extracted from an asymmetric atherosclerotic image derived by the intravascular ultrasound (IVUS) technique. The injected drug at the luminal inlet is transported with the streaming blood which is considered Newtonian. An irreversible uptake kinetics of the injected drug at the lumen-tissue interface from the luminal side to the tissue domains is assumed. Subsequently, the drug is dispersed within the tissue followed by its retention in the extracellular matrix (ECM) and by receptor-mediated binding. The Marker and Cell (MAC) method has been leveraged to get a quantitative insight into the model considered. The effect of the wall absorption parameter on the concentration of all drug forms (free as well as two-phase bound) has been thoroughly investigated, and some other important factors, such as the averaged concentration, the tissue content, the fractional effect, the concentration variance and the effectiveness of drug have been graphically analyzed to gain a clear understanding of endovascular delivery. The simulated results predict that with increasing values of the absorption parameter, the averaged concentrations of all drug forms do decrease. An early saturation of binding sites takes place for smaller values of the absorption parameter, and also rapid saturation of ECM binding sites occurs as compared to receptor binding sites. Results also predict the influence of surface roughness as well as asymmetry of the domain about the centerline on the distribution and retention of drug. A thorough sensitivity analysis has been carried out to determine the influence of some parameters involved.
Collapse
|
13
|
Shim JW, Kim SS, Kim HK, Bae IH, Park DS, Park JK, Kim JU, Kim HB, Lee MY, Kim JS, Kim JH, Koo BS, Jeong KJ, Kim SU, Kim MC, Sim DS, Hong YJ, Ahn Y, Lim KS, Jeong MH. Effect of Novel Polymer-Free Nitrogen-Doped Titanium Dioxide Film-Coated Coronary Stent Loaded With Mycophenolic Acid. Front Bioeng Biotechnol 2021; 9:650408. [PMID: 34778222 PMCID: PMC8585759 DOI: 10.3389/fbioe.2021.650408] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 10/15/2021] [Indexed: 01/12/2023] Open
Abstract
Background: Titanium is commonly used in blood-exposed medical devices because it has superior blood compatibility. Mycophenolic acid inhibits the proliferation of vascular smooth muscle cells. This study examined the effect of a non-polymer TiO2 thin film–coated stent with mycophenolic acid in a porcine coronary overstretch restenosis model. Methods: Thirty coronary arteries in 15 pigs were randomized into three groups in which the coronary arteries were treated with a TiO2 film–coated stent with mycophenolic acid (NTM, n = 10), everolimus-eluting stent with biodegradable polymer (EES, n = 10), or TiO2 film–coated stent (NT, n = 10). A histopathologic analysis was performed 28 days after the stenting. Results: There were no significant intergroup differences in injury score, internal elastic lamina area, or inflammation score. Percent area stenosis was significantly smaller in the NTM and EES groups than in the NT group (36.1 ± 13.63% vs. 31.6 ± 7.74% vs. 45.5 ± 18.96%, respectively, p = 0.0003). Fibrin score was greater in the EES group than in the NTM and NT groups [2.0 (range, 2.0–2.0) vs. 1.0 (range, 1.0–1.75) vs. 1.0 (range, 1.0–1.0), respectively, p < 0.0001]. The in-stent occlusion rate measured by micro-computed tomography demonstrated similar percent area stenosis rates on histology analysis (36.1 ± 15.10% in NTM vs. 31.6 ± 8.89% in EES vs. 45.5 ± 17.26% in NT, p < 0.05). Conclusion: The NTM more effectively reduced neointima proliferation than the NT. Moreover, the inhibitory effect of NTM on smooth muscle cell proliferation was not inferior to that of the polymer-based EES with lower fibrin deposition in this porcine coronary restenosis model.
Collapse
Affiliation(s)
- Jae Won Shim
- Korea Cardiovascular Stent Research Institute, Jangsung, South Korea.,Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Sung Soo Kim
- Division of Cardiology, Chosun University Hospital, Gwangju, South Korea
| | - Hyun Kuk Kim
- Division of Cardiology, Chosun University Hospital, Gwangju, South Korea
| | - In Ho Bae
- Korea Cardiovascular Stent Research Institute, Jangsung, South Korea.,Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Dae Sung Park
- Korea Cardiovascular Stent Research Institute, Jangsung, South Korea.,Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea.,Research Institute of Medical Sciences, Chonnam National University, Gwangju, South Korea
| | | | - Jae Un Kim
- Korea Cardiovascular Stent Research Institute, Jangsung, South Korea.,Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Han Byul Kim
- Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Min Young Lee
- College of Pharmacy, Research Institute of Pharmaceutical Sciences, Kyungpook National University, Daegu, South Korea
| | - Joong Sun Kim
- College of Veterinary Medicine, Chonnam National University, Gwangju, South Korea
| | - Jung Ha Kim
- Korea Cardiovascular Stent Research Institute, Jangsung, South Korea.,Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Bon-Sang Koo
- Futuristic Animal Resource and Research Center, National Primate Research Center, Korea Research Institute of Bioscience and Biotechnology, Chungbuk, South Korea
| | - Kang-Jin Jeong
- Futuristic Animal Resource and Research Center, National Primate Research Center, Korea Research Institute of Bioscience and Biotechnology, Chungbuk, South Korea
| | - Sun-Uk Kim
- Futuristic Animal Resource and Research Center, National Primate Research Center, Korea Research Institute of Bioscience and Biotechnology, Chungbuk, South Korea
| | - Min Chul Kim
- Futuristic Animal Resource and Research Center, National Primate Research Center, Korea Research Institute of Bioscience and Biotechnology, Chungbuk, South Korea
| | - Doo Sun Sim
- Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Young Joon Hong
- Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Youngkeun Ahn
- Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| | - Kyung Seob Lim
- Futuristic Animal Resource and Research Center, National Primate Research Center, Korea Research Institute of Bioscience and Biotechnology, Chungbuk, South Korea
| | - Myung Ho Jeong
- Korea Cardiovascular Stent Research Institute, Jangsung, South Korea.,Cardiovascular Research Center, Chonnam National University Hospital, Gwangju, South Korea
| |
Collapse
|
14
|
Russ JB, Li RL, Herschman AR, Waisman H, Vedula V, Kysar JW, Kalfa D. Design optimization of a cardiovascular stent with application to a balloon expandable prosthetic heart valve. MATERIALS & DESIGN 2021; 209:109977. [PMID: 34366534 PMCID: PMC8336925 DOI: 10.1016/j.matdes.2021.109977] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
A cardiovascular stent design optimization method is proposed with application to a pediatric balloon-expandable prosthetic heart valve. The prosthetic valved conduit may be expanded to a larger permanent diameter in vivo via subsequent transcatheter balloon dilation procedures. While multiple expandable prosthetic heart valves are currently at different stages of development, this work is focused on one particular design in which a stent is situated inside of an expandable polymeric valved conduit. Since the valve and conduit must be joined with a robust manufacturing technique, a polymeric glue layer is inserted between the two, which results in radial retraction of the valved region after expansion. Design of an appropriate stent is proposed to counteract this phenomenon and maintain the desired permanent diameter throughout the device after a single non-compliant balloon dilation procedure. The finite element method is used to compute performance metrics related to the permanent expansion diameter and required radial force. Additionally, failure due not only to high cycle fatigue but also due to ductile fracture is incorporated into the design study through the use of an existing ductile fracture criterion for metals. Surrogate models are constructed with the results of the high fidelity simulations and are subsequently used to numerically obtain a set of Pareto-optimal stent designs. Finally, a single design is identified by optimizing a normalized aggregate objective function with equal weighting of all design objectives.
Collapse
Affiliation(s)
- Jonathan B. Russ
- Columbia University, Department of Civil Engineering and Engineering Mechanics, New York, NY, USA
| | - Richard L. Li
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| | - Abigail R. Herschman
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| | - Haim Waisman
- Columbia University, Department of Civil Engineering and Engineering Mechanics, New York, NY, USA
| | - Vijay Vedula
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
| | - Jeffrey W. Kysar
- Columbia University, Department of Mechanical Engineering, New York, NY, USA
- Department of Otolaryngology Head and Neck Surgery, Columbia University Medical Center, New York, NY, USA
| | - David Kalfa
- Division of Cardiac, Thoracic and Vascular Surgery, Section of Pediatric and Congenital Cardiac Surgery, New-York Presbyterian - Morgan Stanley Children’s Hospital, Columbia University Medical Center, New York, NY, USA
| |
Collapse
|
15
|
Rahvar M, Ahmadi Lakalayeh G, Nazeri N, Marouf BT, Shirzad M, Najafi T Shabankareh A, Ghanbari H. Assessment of structural, biological and drug release properties of electro-sprayed poly lactic acid-dexamethasone coating for biomedical applications. Biomed Eng Lett 2021; 11:393-406. [PMID: 34616584 DOI: 10.1007/s13534-021-00205-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 07/28/2021] [Accepted: 08/20/2021] [Indexed: 10/20/2022] Open
Abstract
The efficacy of an implant is highly depends on its coating characteristics mainly determined by polymer properties and coating technique. Electro-spraying is an inexpensive and versatile coating technique with various advantages for biomedical application. In this study, the efficacy of electro-sprayed (ES) poly lactic acid (PLA)-dexamethasone (DEX) coatings for medical implants was evaluated and compared with spin-coated samples as control. Structural properties of coatings were investigated using X-ray diffraction (XRD) and differential scanning calorimetry (DSC). Confocal and scanning electron microscopy (SEM), contact angle measurement and nanoindentation tests were used to study surface properties. Coating degradation rate and drug release profile were studied for 40 days. Cell viability experiments were also performed on human endothelial (HUVEC) and smooth muscle cells (HUASMC) using MTT assay and SEM. XRD and DSC analysis showed electro-spraying significantly reduce PLA and DEX crystallinity. Surface studies showed ES coatings has significantly higher hydrophobicity and roughness with microbead-nanofiber morphology vs. micro-nanoporous structure of spin-coated samples. Initial burst release of DEX was 22% and 10% after 6 h and total release was 71% and 46% after 40 days for ES and spin-coated samples, respectively. HUVEC viability of ES samples was higher than spin-coated ones after 1 and 4 days. However, dexamethasone release profile reduced HUASMC proliferation in ES PLA-DEX samples in comparison to spin-coated after 1 and 3 days. In conclusion, in vitro results showed potential of ES PLA-DEX as a biocompatible and efficient anti-inflammatory coating with suitable drug release profile for future applications such as coronary drug eluting stents.
Collapse
Affiliation(s)
- Mostafa Rahvar
- Department of Medical Nanotechnology, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences (IUMS), Tehran, Iran.,Department of Medical Nanotechnology, School of Advanced Technologies in Medicine (SATM), Tehran University of Medical Sciences (TUMS), Italia Street, Tehran, Iran
| | - Gholamreza Ahmadi Lakalayeh
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine (SATM), Tehran University of Medical Sciences (TUMS), Italia Street, Tehran, Iran
| | - Niloofar Nazeri
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine (SATM), Tehran University of Medical Sciences (TUMS), Italia Street, Tehran, Iran.,Research Institute for Prevention of Non-Communicable Diseases, Qazvin University of Medical Sciences, Qazvin, Iran
| | - Bahereh T Marouf
- Department of Materials Science and Engineering, Faculty of Engineering, Urmia University, Urmia, Iran
| | - Mahdieh Shirzad
- Department of Microbiology, School of Biology and Center of Excellence in Phylogeny of Living Organisms, College of Science, University of Tehran, Tehran, Iran
| | - Azar Najafi T Shabankareh
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine (SATM), Tehran University of Medical Sciences (TUMS), Italia Street, Tehran, Iran
| | - Hossein Ghanbari
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine (SATM), Tehran University of Medical Sciences (TUMS), Italia Street, Tehran, Iran.,Research Center for Advanced Technologies in Cardiovascular Medicine, Tehran Heart Center, Tehran University of Medical Sciences (TUMS), Tehran, Iran
| |
Collapse
|
16
|
SARIFUDDIN, ALSEMIRY REIMAD, MANDAL PRASHANTAKUMAR. EFFECTS OF COATING PROPERTIES ON CONTROLLED DELIVERY FROM AN EMBEDDED DRUG-ELUTING STENT: A SIMULATION STUDY. J BIOL SYST 2021. [DOI: 10.1142/s0218339021500145] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The present investigation deals with the effects of biodegradable, biodurable and polymer-free coating of a stent on the release mechanism of the drug in a porous medium. The Brinkman equations for the interstitial fluid, the unsteady convection-diffusion-reaction equation for the transport of free drug in the tissue and the unsteady reaction equations for the bound as well as the internalized drug have been considered. In the coating, the transport of drug has been modeled as a diffusion process. Effects of different percentages of the embedment, convection and various coating properties of the stent on the transport of free drug, its retention and the internalization of the bound drug have been studied. Immersed Boundary Method (IBM) in the staggered grid formulation (IBM-MAC) has been used to tackle numerically the system of nonlinear governing equations. Simulated results predict the fastest release of drug from a biodegradable coating, but the averaged concentrations of all drug forms do reach a quasi-steady state in case of a biodurable coating irrespective of the degrees of embedment. Moreover, for all embedment levels of the stent, a biodegradable coating is superior to that of biodurable and polymer-free coating in the presence/absence of convection for larger times, but this superiority is lost for smaller times. Unlike biodurable coating, it is also predicted that the more the embedment level does not necessarily imply the more the effectiveness of delivery for biodegradable and polymer-free coatings of a stent.
Collapse
Affiliation(s)
- SARIFUDDIN
- Department of Mathematics, Berhampore College, P.O.-Berhampore, Dist.-Murshidabad, WB 742101, India
| | - REIMA D. ALSEMIRY
- Department of Mathematics, Faculty of Science, Taibah University, P.O. Box 89, Yanbu 41911, Saudi Arabia
- Department of Mathematical Sciences, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | | |
Collapse
|
17
|
Song J, Kouidri S, Bakir F. Review on the numerical investigations of mass transfer from drug eluting stent. Biocybern Biomed Eng 2021. [DOI: 10.1016/j.bbe.2021.06.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
18
|
The Use of Bioactive Polymers for Intervention and Tissue Engineering: The New Frontier for Cardiovascular Therapy. Polymers (Basel) 2021; 13:polym13030446. [PMID: 33573282 PMCID: PMC7866823 DOI: 10.3390/polym13030446] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 01/19/2021] [Accepted: 01/25/2021] [Indexed: 12/28/2022] Open
Abstract
Coronary heart disease remains one of the leading causes of death in most countries. Healthcare improvements have seen a shift in the presentation of disease with a reducing number of ST-segment elevation myocardial infarctions (STEMIs), largely due to earlier reperfusion strategies such as percutaneous coronary intervention (PCI). Stents have revolutionized the care of these patients, but the long-term effects of these devices have been brought to the fore. The conceptual and technologic evolution of these devices from bare-metal stents led to the creation and wide application of drug-eluting stents; further research introduced the idea of polymer-based resorbable stents. We look at the evolution of stents and the multiple advantages and disadvantages offered by each of the different polymers used to make stents in order to identify what the stent of the future may consist of whilst highlighting properties that are beneficial to the patient alongside the role of the surgeon, the cardiologist, engineers, chemists, and biophysicists in creating the ideal stent.
Collapse
|
19
|
Anbalakan K, Toh HW, Ang HY, Buist ML, Leo HL. Assessing the influence of atherosclerosis on drug coated balloon therapy using computational modelling. Eur J Pharm Biopharm 2020; 158:72-82. [PMID: 33075477 DOI: 10.1016/j.ejpb.2020.09.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 09/11/2020] [Accepted: 09/21/2020] [Indexed: 10/23/2022]
Abstract
Interventional therapies such as drug-eluting stents (DES) and drug-coated balloons (DCB) have significantly improved the clinical outcomes of patients with coronary occlusions in recent years. Despite this marked improvement, ischemic cardiovascular disease remains the most common cause of death worldwide. To address this, research efforts are focused on improving the safety and efficacy of the next generation of these devices. However, current experimental methods are unable to account for the influence of atherosclerotic lesions on drug uptake and retention. Therefore, in this study, we used an integrated approach utilizing both in vitro and in silico methods to assess the performance of DCB therapy. This approach was validated against existing in vivo results before being used to numerically estimate the effect of the atheroma. A bolus release of sirolimus was observed with our coating matrix. This, coupled with the rapid saturation of specific and non-specific binding sites observed in our study, indicated that increasing the therapeutic dose coated onto the balloons might not necessarily result in greater uptake and/or retention. Additionally, our findings alluded to an optimal exposure time, dependent on the coating matrix, for the DCBs to be expanded against the vessel. Moreover, our findings suggest that a biphasic drug release profile might be beneficial for establishing and maintaining the saturation of bindings sites within severely occluded vessels. Ultimately, we have demonstrated that computational methods may be capable of assessing the efficacy of DCB therapy as well as predict the influence of atherosclerotic lesions on said efficacy.
Collapse
Affiliation(s)
- Karthic Anbalakan
- Department of Biomedical Engineering, National University of Singapore, Singapore 117576, Singapore.
| | - Han Wei Toh
- Department of Biomedical Engineering, National University of Singapore, Singapore 117576, Singapore; National Heart Research Institute Singapore, National Heart Center Singapore 169609, Singapore
| | - Hui Ying Ang
- Department of Biomedical Engineering, National University of Singapore, Singapore 117576, Singapore; National Heart Research Institute Singapore, National Heart Center Singapore 169609, Singapore
| | - Martin Lindsay Buist
- Department of Biomedical Engineering, National University of Singapore, Singapore 117576, Singapore.
| | - Hwa Liang Leo
- Department of Biomedical Engineering, National University of Singapore, Singapore 117576, Singapore.
| |
Collapse
|
20
|
Sarifuddin, Roy S, Mandal PK. Computational model of stent-based delivery from a half-embedded two-layered coating. Comput Methods Biomech Biomed Engin 2020; 23:815-831. [PMID: 32588648 DOI: 10.1080/10255842.2020.1767775] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
An attempt is made in the present investigation to develop a computational model for the purpose of studying the effect of interstitial flow in the porous media on the distribution of drug eluted from a half-embedded drug-eluting stent and its retention in the presence of two-layered coating of the stent. The transport of free drug inside the coatings is considered as an unsteady diffusion process while that in the tissue as an unsteady convection-diffusion-reaction process. The bound drug is governed by an unsteady reaction process only. Immersed boundary method (IBM) in the staggered grid formulation, popularly known as marker and cell (MAC) method, has been leveraged to tackle numerically the governing equations. This model highlights the benefits of consideration of two-layered coating and does predict underlying mechanism for better efficacy by tweaking the kinetics parameters. Comparisons are also made with the results available for stent-based delivery.
Collapse
Affiliation(s)
- Sarifuddin
- Department of Mathematics, Berhampore College, Berhampore, West Bengal, India
| | - Somnath Roy
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, West Bengal, India
| | | |
Collapse
|
21
|
Escuer J, Cebollero M, Peña E, McGinty S, Martínez MA. How does stent expansion alter drug transport properties of the arterial wall? J Mech Behav Biomed Mater 2020; 104:103610. [DOI: 10.1016/j.jmbbm.2019.103610] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Revised: 12/23/2019] [Accepted: 12/29/2019] [Indexed: 11/28/2022]
|
22
|
Zhi B, Mao Y. Vapor-Deposited Nanocoatings for Sustained Zero-Order Release of Antiproliferative Drugs. ACS APPLIED BIO MATERIALS 2020; 3:1088-1096. [DOI: 10.1021/acsabm.9b01044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Bin Zhi
- Departments of Biosystems Engineering, Oklahoma State University, Stillwater, Oklahoma 74078, United States
| | - Yu Mao
- Departments of Biosystems Engineering, Oklahoma State University, Stillwater, Oklahoma 74078, United States
| |
Collapse
|
23
|
McKittrick CM, Cardona MJ, Black RA, McCormick C. Development of a Bioactive Polymeric Drug Eluting Coronary Stent Coating Using Electrospraying. Ann Biomed Eng 2019; 48:271-281. [PMID: 31441008 PMCID: PMC6928095 DOI: 10.1007/s10439-019-02346-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 08/13/2019] [Indexed: 02/05/2023]
Abstract
Drug-eluting stents are now routinely used in the treatment of acute coronary syndromes caused by coronary artery disease. Whilst the sustained release of anti-proliferative drugs from these devices has greatly reduced the need for repeat revascularisation procedures, this approach is not suitable for all patients and appears to delay regrowth of the endothelium, necessitating the use of prolonged dual anti-platelet therapy. Although the development of more advanced stent platforms and drug coatings has produced modest improvements in performance, these devices have not fully addressed the limitations experienced with their first-generation counterparts. In the present study, we developed a novel stent coating that provides controlled sirolimus release from a bioactive polymer (accelerate™ AT) that has previously been shown to support endothelial cell growth in vitro. A bespoke electrospray deposition process provided control over the coating thickness, surface roughness, drug load, and release kinetics. The resultant optimised coating combines rapid release of an anti-proliferative agent from a bioactive polymer coating that promotes re-endothelialisation, thereby offering potential protection against in-stent restenosis and thrombosis. This novel, dual-action coating therefore has significant therapeutic potential, with the enhanced control of drug load and release kinetics offered by electrospray deposition also opening up opportunities for more personalised treatment approaches. Further development and evaluation of these technologies in vitro and in vivo is therefore warranted.
Collapse
Affiliation(s)
- C M McKittrick
- Department of Biomedical Engineering, University of Strathclyde, Graham Hills Building, 40 George Street, Glasgow, G1 1QE, UK.
| | - M J Cardona
- Department of Biomedical Engineering, University of Strathclyde, Graham Hills Building, 40 George Street, Glasgow, G1 1QE, UK
| | - R A Black
- Department of Biomedical Engineering, University of Strathclyde, Graham Hills Building, 40 George Street, Glasgow, G1 1QE, UK
| | - C McCormick
- Department of Biomedical Engineering, University of Strathclyde, Graham Hills Building, 40 George Street, Glasgow, G1 1QE, UK
| |
Collapse
|
24
|
McKittrick CM, McKee S, Kennedy S, Oldroyd K, Wheel M, Pontrelli G, Dixon S, McGinty S, McCormick C. Combining mathematical modelling with in vitro experiments to predict in vivo drug-eluting stent performance. J Control Release 2019; 303:151-161. [PMID: 30878363 DOI: 10.1016/j.jconrel.2019.03.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 03/08/2019] [Accepted: 03/10/2019] [Indexed: 11/15/2022]
Abstract
In this study, we developed a predictive model of in vivo stent based drug release and distribution that is capable of providing useful insights into performance. In a combined mathematical modelling and experimental approach, we created two novel sirolimus-eluting stent coatings with quite distinct doses and release kinetics. Using readily measurable in vitro data, we then generated parameterised mathematical models of drug release. These were then used to simulate in vivo drug uptake and retention. Finally, we validated our model predictions against data on drug kinetics and efficacy obtained in a small in vivo evaluation. In agreement with the in vivo experimental results, our mathematical model predicted consistently higher sirolimus content in tissue for the higher dose stents compared with the lower dose stents. High dose stents resulted in statistically significant improvements in three key efficacy measures, providing further evidence of a basic relationship between dose and efficacy within DES. However, our mathematical modelling suggests a more complex relationship is at play, with efficacy being dependent not only on delivering an initial dose of drug sufficient to achieve receptor saturation, but also on the consequent drug release rate being tuned to ensure prolonged saturation. In summary, we have demonstrated that our combined in vitro experimental and mathematical modelling framework may be used to predict in vivo DES performance, opening up the possibility of an in silico approach to optimising the drug release profile and ultimately the effectiveness of the device.
Collapse
Affiliation(s)
- Craig M McKittrick
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Sean McKee
- Department of Mathematics & Statistics, University of Strathclyde, Glasgow, UK
| | - Simon Kennedy
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, UK
| | | | - Marcus Wheel
- Department of Mechanical & Aerospace Engineering, University of Strathclyde, Glasgow, UK
| | | | | | - Sean McGinty
- Division of Biomedical Engineering, University of Glasgow, Glasgow, UK.
| | | |
Collapse
|
25
|
Strobel HA, Qendro EI, Alsberg E, Rolle MW. Targeted Delivery of Bioactive Molecules for Vascular Intervention and Tissue Engineering. Front Pharmacol 2018; 9:1329. [PMID: 30519186 PMCID: PMC6259603 DOI: 10.3389/fphar.2018.01329] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 10/29/2018] [Indexed: 01/25/2023] Open
Abstract
Cardiovascular diseases are the leading cause of death in the United States. Treatment often requires surgical interventions to re-open occluded vessels, bypass severe occlusions, or stabilize aneurysms. Despite the short-term success of such interventions, many ultimately fail due to thrombosis or restenosis (following stent placement), or incomplete healing (such as after aneurysm coil placement). Bioactive molecules capable of modulating host tissue responses and preventing these complications have been identified, but systemic delivery is often harmful or ineffective. This review discusses the use of localized bioactive molecule delivery methods to enhance the long-term success of vascular interventions, such as drug-eluting stents and aneurysm coils, as well as nanoparticles for targeted molecule delivery. Vascular grafts in particular have poor patency in small diameter, high flow applications, such as coronary artery bypass grafting (CABG). Grafts fabricated from a variety of approaches may benefit from bioactive molecule incorporation to improve patency. Tissue engineering is an especially promising approach for vascular graft fabrication that may be conducive to incorporation of drugs or growth factors. Overall, localized and targeted delivery of bioactive molecules has shown promise for improving the outcomes of vascular interventions, with technologies such as drug-eluting stents showing excellent clinical success. However, many targeted vascular drug delivery systems have yet to reach the clinic. There is still a need to better optimize bioactive molecule release kinetics and identify synergistic biomolecule combinations before the clinical impact of these technologies can be realized.
Collapse
Affiliation(s)
- Hannah A. Strobel
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, United States
| | - Elisabet I. Qendro
- Graduate School of Biomedical Sciences, University of Massachusetts Medical School, Worcester, MA, United States
| | - Eben Alsberg
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Marsha W. Rolle
- Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA, United States
| |
Collapse
|
26
|
Saha R. A Computational Approach for Stent Elution Rate Determined Specific Drug Binding and Receptor-mediated Effects in Arterial Tissue. JOURNAL OF EXPLORATORY RESEARCH IN PHARMACOLOGY 2018; 3:105-118. [DOI: 10.14218/jerp.2018.00018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
27
|
Farah S, Domb AJ. Crystalline paclitaxel coated DES with bioactive protective layer development. J Control Release 2018; 271:107-117. [PMID: 29289571 DOI: 10.1016/j.jconrel.2017.12.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 11/29/2017] [Accepted: 12/27/2017] [Indexed: 01/01/2023]
Abstract
Drug eluting stents (DES) based on polymeric-carriers currently lead the market, however, reports on clinical complications encourage the development of safer and more effective DES. We recently reported on carrier-free DES based on rapamycin crystalline coating as a potential therapeutic solution. Here, we report for the first time surface crystallization of paclitaxel (PT) onto metallic stents. The physicochemical principles of crystallization and key process parameters were extensively studied for fabrication of controllable and homogeneous crystalline coatings on stent scaffolds. Stents loaded with nearly 100μg PT were chosen as a potential therapeutic device with a multilayer coating of 4-7μm thickness. In vitro PT release from these coated stents shows constant release for at least 28days with 10% cumulatively released. The effect of fast dissolving top coating on the physical stability of the coated stent was determined. The top coating enhances the mechanical stability of the crystalline coating during deployment and expansion simulations. Also, incorporating PT in the protective top coating for developing bioactive top coating for multilayer controlled release purpose was intensively studied. This process has wide applications that can be further implemented for other drugs for effective local drug delivery from implantable medical devices.
Collapse
Affiliation(s)
- Shady Farah
- Institute of Drug Research, School of Pharmacy-Faculty of Medicine, Center for Nanoscience and Nanotechnology and The Alex Grass Center for Drug Design and Synthesis, The Hebrew University of Jerusalem, 91120, Israel.
| | - Abraham J Domb
- Institute of Drug Research, School of Pharmacy-Faculty of Medicine, Center for Nanoscience and Nanotechnology and The Alex Grass Center for Drug Design and Synthesis, The Hebrew University of Jerusalem, 91120, Israel.
| |
Collapse
|
28
|
Mandal AP, Mandal PK. Distribution and retention of drug through an idealised atherosclerotic plaque eluted from a half-embedded stent. ACTA ACUST UNITED AC 2017. [DOI: 10.1007/s40435-017-0372-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
29
|
Naghipoor J, Rabczuk T. A mechanistic model for drug release from PLGA-based drug eluting stent: A computational study. Comput Biol Med 2017; 90:15-22. [DOI: 10.1016/j.compbiomed.2017.09.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 09/01/2017] [Accepted: 09/01/2017] [Indexed: 11/15/2022]
|
30
|
Long-term (2-5 years) adverse clinical outcomes associated with ZES versus SES, PES and EES: A Meta-Analysis. Sci Rep 2017; 7:6385. [PMID: 28743907 PMCID: PMC5527000 DOI: 10.1038/s41598-017-06705-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Accepted: 06/16/2017] [Indexed: 01/23/2023] Open
Abstract
Several previously published trials comparing Zotarolimus Eluting Stents (ZES) with Sirolimus Eluting Stents (SES), Paclitaxel Eluting Stents (PES) or Everolimus Eluting Stents (EES) at a follow up period of 1 year, were continually being followed up in order to assess the long-term outcomes. In this meta-analysis, we aimed to compare the long-term (2–5 years) adverse clinical outcomes which were associated with ZES versus SES, PES and EES following Percutaneous Coronary Intervention (PCI). Risk Ratios (RR) with 95% Confidence Intervals (CIs) were generated and the analysis was carried out by the RevMan 5.3 software. In this analysis with a total number of 17,606 participants, ZES and EES were associated with similar adverse outcomes including Stent Thrombosis (ST), myocardial infarction (MI), major adverse cardiac events and repeated revascularization. When ZES were compared with SES and PES during the long-term, MI and definite or probable ST were significantly lower with ZES, with RR: 1.35, 95% CI: 1.17–1.56; P = 0.0001 and RR: 1.91, 95% CI: 1.33–2.75; P = 0.0004 respectively whereas the other adverse outcomes were similarly manifested. Future research should be able to confirm this hypothesis.
Collapse
|
31
|
Mandal AP, Mandal PK. Computational Modelling of Three-phase Stent-based Delivery. JOURNAL OF EXPLORATORY RESEARCH IN PHARMACOLOGY 2017; 2:31-40. [DOI: 10.14218/jerp.2017.00001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
32
|
Udenni Gunathilake TMS, Ching YC, Ching KY, Chuah CH, Abdullah LC. Biomedical and Microbiological Applications of Bio-Based Porous Materials: A Review. Polymers (Basel) 2017; 9:E160. [PMID: 30970839 PMCID: PMC6431923 DOI: 10.3390/polym9050160] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 04/15/2017] [Accepted: 04/25/2017] [Indexed: 12/27/2022] Open
Abstract
Extensive employment of biomaterials in the areas of biomedical and microbiological applications is considered to be of prime importance. As expected, oil based polymer materials were gradually replaced by natural or synthetic biopolymers due to their well-known intrinsic characteristics such as biodegradability, non-toxicity and biocompatibility. Literature on this subject was found to be expanding, especially in the areas of biomedical and microbiological applications. Introduction of porosity into a biomaterial broadens the scope of applications. In addition, increased porosity can have a beneficial effect for the applications which exploit their exceptional ability of loading, retaining and releasing of fluids. Different applications require a unique set of pore characteristics in the biopolymer matrix. Various pore morphologies have different characteristics and contribute different performances to the biopolymer matrix. Fabrication methods for bio-based porous materials more related to the choice of material. By choosing the appropriate combination of fabrication technique and biomaterial employment, one can obtain tunable pore characteristic to fulfill the requirements of desired application. In our previous review, we described the literature related to biopolymers and fabrication techniques of porous materials. This paper we will focus on the biomedical and microbiological applications of bio-based porous materials.
Collapse
Affiliation(s)
- T M S Udenni Gunathilake
- Department of Chemical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Yern Chee Ching
- Department of Chemical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Kuan Yong Ching
- University of Reading Malaysia, Persiaran Graduan, Kota Ilmu, Educity, Iskandar Puteri Johor 79200, Malaysia.
| | - Cheng Hock Chuah
- Department of Chemistry, Faculty of Science, University of Malaya, Kuala Lumpur 50603, Malaysia.
| | - Luqman Chuah Abdullah
- Department of Chemical Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia.
| |
Collapse
|
33
|
Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling. Ann Biomed Eng 2017; 45:853-872. [PMID: 28160103 DOI: 10.1007/s10439-017-1806-8] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Accepted: 01/28/2017] [Indexed: 01/02/2023]
|
34
|
Sun W, Huang Y, Yin T, Wang J, Du R, Qiu J, Zhang Y, Wang Y, Chen J, Wang G. Effects of elemene on inhibiting proliferation of vascular smooth muscle cells and promoting reendothelialization at the stent implantation site. Biomater Sci 2017; 5:1144-1155. [DOI: 10.1039/c7bm00190h] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Elemene coated stents prepared by electrospray could inhibit proliferation of VSMCs and promote endothelialization after implantation into rabbit iliac arteries.
Collapse
|
35
|
Ferreira JA, Gonçalves L, Naghipoor J, de Oliveira P, Rabczuk T. The influence of atherosclerotic plaques on the pharmacokinetics of a drug eluted from bioabsorbable stents. Math Biosci 2017; 283:71-83. [DOI: 10.1016/j.mbs.2016.11.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 09/03/2016] [Accepted: 11/05/2016] [Indexed: 11/28/2022]
|
36
|
Dalal A. Organ transplantation and drug eluting stents: Perioperative challenges. World J Transplant 2016; 6:620-631. [PMID: 28058211 PMCID: PMC5175219 DOI: 10.5500/wjt.v6.i4.620] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 07/18/2016] [Accepted: 09/18/2016] [Indexed: 02/05/2023] Open
Abstract
Patients listed for organ transplant frequently have severe coronary artery disease (CAD), which may be treated with drug eluting stents (DES). Everolimus and zotarolimus eluting stents are commonly used. Newer generation biolimus and novolimus eluting biodegradable stents are becoming increasingly popular. Patients undergoing transplant surgery soon after the placement of DES are at increased risk of stent thrombosis (ST) in the perioperative period. Dual antiplatelet therapy (DAPT) with aspirin and a P2Y12 inhibitor such as clopidogrel, prasugrel and ticagrelor is instated post stenting to decrease the incident of ST. Cangrelor has recently been approved by Food and Drug Administration and can be used as a bridging antiplatelet drug. The risk of ischemia vs bleeding must be considered when discontinuing or continuing DAPT for surgery. Though living donor transplant surgery is an elective procedure and can be optimally timed, cadaveric organ availability is unpredictable, therefore, discontinuation of antiplatelet medication cannot be optimally timed. The type of stent and timing of transplant surgery can be of utmost importance. Many platelet function point of care tests such as Light Transmittance Aggregrometry, Thromboelastography Platelet Mapping, VerifyNow, Multiple Electrode Aggregrometry are used to assess bleeding risk and guide perioperative platelet transfusion. Response to allogenic platelet transfusion to control severe intraoperative bleeding may differ with the antiplatelet drug. In stent thrombosis is an emergency where management with either a drug eluting balloon or a DES has shown superior outcomes. Post-transplant complications often involved stenosis of an important vessel that may need revascularization. DES are now used for endovascular interventions for transplant orthotropic heart CAD, hepatic artery stenosis post liver transplantation, transplant renal artery stenosis following kidney transplantation, etc. Several antiproliferative drugs used in the DES are inhibitors of mammalian target of rapamycin. Thus they are used for post-transplant immunosuppression to prevent acute rejection in recipients with heart, liver, lung and kidney transplantation. This article describes in detail the various perioperative challenges encountered in organ transplantation surgery and patients with drug eluting stents.
Collapse
|
37
|
Karimi M, Zare H, Bakhshian Nik A, Yazdani N, Hamrang M, Mohamed E, Sahandi Zangabad P, Moosavi Basri SM, Bakhtiari L, Hamblin MR. Nanotechnology in diagnosis and treatment of coronary artery disease. Nanomedicine (Lond) 2016; 11:513-30. [PMID: 26906471 DOI: 10.2217/nnm.16.3] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Nanotechnology could provide a new complementary approach to treat coronary artery disease (CAD) which is now one of the biggest killers in the Western world. The course of events, which leads to atherosclerosis and CAD, involves many biological factors and cellular disease processes which may be mitigated by therapeutic methods enhanced by nanotechnology. Nanoparticles can provide a variety of delivery systems for cargoes such as drugs and genes that can address many problems within the arteries. In order to improve the performance of current stents, nanotechnology provides different nanomaterial coatings, in addition to controlled-release nanocarriers, to prevent in-stent restenosis. Nanotechnology can increase the efficiency of drugs, improve local and systematic delivery to atherosclerotic plaques and reduce the inflammatory or angiogenic response after intravascular intervention. Nanocarriers have potential for delivery of imaging and diagnostic agents to precisely targeted destinations. This review paper will cover the current applications and future outlook of nanotechnology, as well as the main diagnostic methods, in the treatment of CAD.
Collapse
Affiliation(s)
- Mahdi Karimi
- Department of Medical Nanotechnology, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Hossein Zare
- Biomaterials Group, Materials Science & Engineering Department, Iran University of Science & Technology, P.O. Box 1684613114 Tehran, Iran
| | - Amirala Bakhshian Nik
- Division of Biomedical Engineering, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran 1439957131 Tehran, Iran
| | - Narges Yazdani
- Biomaterials Group, Materials Science & Engineering Department, Iran University of Science & Technology, P.O. Box 1684613114 Tehran, Iran
| | - Mohammad Hamrang
- Biomaterials Group, Materials Science & Engineering Department, Iran University of Science & Technology, P.O. Box 1684613114 Tehran, Iran
| | - Elmira Mohamed
- Biomaterials Group, Materials Science & Engineering Department, Iran University of Science & Technology, P.O. Box 1684613114 Tehran, Iran
| | - Parham Sahandi Zangabad
- Department of Materials Science & Engineering, Sharif University of Technology, P.O. Box 11365-9466, 14588 Tehran, Iran
| | - Seyed Masoud Moosavi Basri
- School of Computer Science, Institute for Research in Fundamental Sciences, Tehran, Iran.,Civil & Environmental Engineering Department, Shahid Beheshti University, Tehran, Iran
| | - Leila Bakhtiari
- Biomaterials Group, Materials Science & Engineering Department, Iran University of Science & Technology, P.O. Box 1684613114 Tehran, Iran
| | - Michael R Hamblin
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA.,Department of Dermatology, Harvard Medical School, Boston, MA 02115, USA.,Harvard-MIT Division of Health Sciences & Technology, Cambridge, MA 02139, USA
| |
Collapse
|
38
|
McGinty S, Pontrelli G. A general model of coupled drug release and tissue absorption for drug delivery devices. J Control Release 2015; 217:327-36. [DOI: 10.1016/j.jconrel.2015.09.025] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2015] [Revised: 08/24/2015] [Accepted: 09/14/2015] [Indexed: 11/26/2022]
|
39
|
Design Optimisation of Coronary Artery Stent Systems. Ann Biomed Eng 2015; 44:357-67. [DOI: 10.1007/s10439-015-1373-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Accepted: 06/23/2015] [Indexed: 10/23/2022]
|