1
|
Zheng H, Li J, Leung SSY. Inhalable polysorbates stabilized nintedanib nanocrystals to facilitate pulmonary nebulization and alveolar macrophage evasion. BIOMATERIALS ADVANCES 2025; 166:214084. [PMID: 39471574 DOI: 10.1016/j.bioadv.2024.214084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 10/18/2024] [Accepted: 10/22/2024] [Indexed: 11/01/2024]
Abstract
Pulmonary delivery of nintedanib has noticeable advantages over the current oral administration in managing idiopathic pulmonary fibrosis (IPF). However, it remains a challenge to construct an efficient lung delivery system for insoluble nintedanib to resist nebulization instabilities and alveolar macrophage clearance. Herein, we attempted to develop nintedanib as inhalable nanocrystals stabilized with polysorbates. Different types of polysorbates (polysorbate 20, 40, 60, 80) and various drug-surfactant molar ratios (DSR = 10, 30, 60) were screened to determine the optimal nintedanib nanocrystal formulation. Most formulations (except those stabilized by polysorbate 40) could tailor nintedanib nanocrystals with sizes around 600 nm, and the nebulization-caused drug loss could be significantly reduced when DSR increased to 60. Meanwhile, all nanocrystals boosted the in vitro drug dissolution rate and improved the aerosol performance of nintedanib. Although nebulization-caused particle aggregation was found in most formulations, the nanocrystal stabilized with polysorbate 80 at DSR 60 presented no apparent size change after nebulization. This formulation exhibited superior alveolar macrophage evasion, enhanced fibroblast cluster infiltration, and improved fibroblast cluster inhibition compared with other formulations, indicating its significant potential for pulmonary nintedanib delivery. Overall, this study explored the potential of polysorbates in stabilizing nintedanib nanocrystals for nebulization and proposed practical solutions to transfer nintedanib from oral to lung delivery.
Collapse
Affiliation(s)
- Huangliang Zheng
- School of Pharmacy, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Jiaqi Li
- School of Pharmacy, The Chinese University of Hong Kong, Shatin, Hong Kong
| | | |
Collapse
|
2
|
Abu Elella MH, Al Khatib AO, Al-Obaidi H. Spray-Dried Nanolipid Powders for Pulmonary Drug Delivery: A Comprehensive Mini Review. Pharmaceutics 2024; 16:680. [PMID: 38794342 PMCID: PMC11125033 DOI: 10.3390/pharmaceutics16050680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/28/2024] [Accepted: 05/15/2024] [Indexed: 05/26/2024] Open
Abstract
Lung diseases have received great attention in the past years because they contribute approximately one-third of the total global mortality. Pulmonary drug delivery is regarded as one of the most appealing routes to treat lung diseases. It addresses numerous drawbacks linked to traditional dosage forms. It presents notable features, such as, for example, a non-invasive route, localized lung drug delivery, low enzymatic activity, low drug degradation, higher patient compliance, and avoiding first-pass metabolism. Therefore, the pulmonary route is commonly explored for delivering drugs both locally and systemically. Inhalable nanocarrier powders, especially, lipid nanoparticle formulations, including solid-lipid and nanostructured-lipid nanocarriers, are attracting considerable interest in addressing respiratory diseases thanks to their significant advantages, including deep lung deposition, biocompatibility, biodegradability, mucoadhesion, and controlled drug released. Spray drying is a scalable, fast, and commercially viable technique to produce nanolipid powders. This review highlights the ideal criteria for inhalable spray-dried SLN and NLC powders for the pulmonary administration route. Additionally, the most promising inhalation devices, known as dry powder inhalers (DPIs) for the pulmonary delivery of nanolipid powder-based medications, and pulmonary applications of SLN and NLC powders for treating chronic lung conditions, are considered.
Collapse
Affiliation(s)
- Mahmoud H. Abu Elella
- School of Pharmacy, University of Reading, Reading RG6 6UR, UK; (M.H.A.E.); (A.O.A.K.)
| | - Arwa Omar Al Khatib
- School of Pharmacy, University of Reading, Reading RG6 6UR, UK; (M.H.A.E.); (A.O.A.K.)
- Faculty of Pharmacy, Al Ahliyya Amman University, Amman 19111, Jordan
| | - Hisham Al-Obaidi
- School of Pharmacy, University of Reading, Reading RG6 6UR, UK; (M.H.A.E.); (A.O.A.K.)
| |
Collapse
|
3
|
Peng Y, Wu Z, Lin K, Huang R, Huang J, Lin J, Chen S, Zheng J, Gao Y. Exploration of quality criteria for the detection of peak inspiratory flow under different resistance conditions. Technol Health Care 2024; 32:9-18. [PMID: 37393451 PMCID: PMC10789355 DOI: 10.3233/thc-220905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 04/28/2023] [Indexed: 07/03/2023]
Abstract
BACKGROUND At present, robust quality criteria and methods for the assessment of Peak inspiratory flow meter performance are lacking. OBJECTIVE A standard flow-volume simulator for quality control analyses of an inhalation assessment device was utilized with different simulated resistance levels in order to propose a quality testing method and associated standard for this device type. METHODS A standard flow-volume simulator was utilized to assess the performance of an In-Check DIAL® (Device I) and an intelligent inhalation assessment device (Device P) at a fixed volume and flow rate. Indices used to evaluate these two instruments included repeatability, accuracy, linearity, and impedance. RESULTS Both devices exhibited good repeatability (<± 3 L/min). The difference between test results and standard simulator values for Device P was less than ± 5 L/min at resistance level R1 but higher than ± 5 L/min at resistance levels R2-5, while Device I were greater than 5 L/min at all resistance levels. The relative error for Device P was <± 10% at resistance levels R1, R2, and R4, but > 10% at resistance levels R3 and R5. The relative error values for Device I at all five resistance levels were > 10%. Device P passed the linearity test at the R2 resistance level, while Device I partially passed the linearity test at all five resistance levels. CONCLUSION Standard monitoring methods and standards provide a valuable approach to the more reliable clinical assessment and application of these instruments.
Collapse
Affiliation(s)
| | | | | | - Ruibo Huang
- National Center for Respiratory Medicine, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Jinhai Huang
- National Center for Respiratory Medicine, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Junfeng Lin
- National Center for Respiratory Medicine, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Shubing Chen
- National Center for Respiratory Medicine, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Jinping Zheng
- National Center for Respiratory Medicine, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Yi Gao
- National Center for Respiratory Medicine, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou Institute of Respiratory Health, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, China
| |
Collapse
|
4
|
Shrinath V, Thatikonda A, Pandey I, Marwah V, Deshpande S, Tentu AK, Kishore K, Tyagi R, Yadav A, Choudhary R. A cross sectional observational study on uncontrolled bronchial asthma and inhaler technique among out patients in a tertiary care centre in Western Maharashtra. Lung India 2023; 40:440-444. [PMID: 37787358 PMCID: PMC10553788 DOI: 10.4103/lungindia.lungindia_559_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/08/2023] [Accepted: 04/03/2023] [Indexed: 10/04/2023] Open
Abstract
Background The 2014 Asia Pacific - Asthma Insight and Management (AP-AIM) study showed that none of the Indian asthmatics had controlled asthma when evaluated objectively. Our study aims to detect through objective measurements, uncontrolled asthma in OPD patients, the adequacy of their inhaler technique, and their awareness regarding the importance of inhaler technique. Method The asthma Control Test (ACT) score was used to screen for uncontrolled asthma. A validated objective questionnaire and scoring were used to objectively assess the correctness and awareness of the inhalation technique. Result The study was carried out over 2 month period and 80 patients meeting the inclusion criteria were enrolled. Out of 80 patients; 47 (58.75%) had well-controlled asthma and 33 (41.25%) had uncontrolled asthma. 64 (80%) patients had good, and 16 (20%) had poor inhalation techniques. Among the 64 patients with good inhalation technique 43 (67.18%) had well-controlled asthma and 21 (32.82%) had uncontrolled asthma. Among the 16 patients with poor inhalation technique 4 (25%) had well-controlled asthma and 12 (75%) had uncontrolled asthma. There was a statistically significant association between asthma control and inhaler technique (P value 0.002). In the study population 56 (70%) patients were aware of the inhalation technique and 24 (30%) were unaware of the inhalation technique. Out of the 56 patients who were aware of the inhalation technique 53 (94.64%) had good inhaler technique and 3 (5.36%) had poor inhalation technique. Among the 24 patients who were unaware of the inhaler technique 11 (45.83%) had good inhaler technique and 13 (54.17%) had poor inhaler technique. There was a statistically significant association between awareness of inhaler technique and good inhaler technique (P value 0.001). Conclusion There is a statistically significant association between asthma control and inhaler technique and between inhaler technique and inhaler awareness. Improving the awareness regarding inhaler technique among bronchial asthma patients is the way forward to improve asthma control in our country.
Collapse
Affiliation(s)
- V Shrinath
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| | | | - Indramani Pandey
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| | - Vikas Marwah
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| | | | - Ajai Kumar Tentu
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| | - Kislay Kishore
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| | - Rahul Tyagi
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| | - Aseem Yadav
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| | - Robin Choudhary
- Department of Respiratory Medicine, AICTS, Pune, Maharashtra, India
| |
Collapse
|
5
|
Mahler DA, Watz H, Emerson-Stadler R, Ritz J, Gardev A, Shaikh A, Drummond MB. Clinical Implications of Peak Inspiratory Flow in COPD: Post Hoc Analyses of the TRONARTO Study. Int J Chron Obstruct Pulmon Dis 2023; 18:1729-1740. [PMID: 37599896 PMCID: PMC10432827 DOI: 10.2147/copd.s404243] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 07/24/2023] [Indexed: 08/22/2023] Open
Abstract
Background In patients with COPD, inhalation ability should be assessed when considering inhaler choice. To evaluate whether the soft mist inhaler (SMI) is suitable for COPD patients irrespective of inhalation ability, the TRONARTO study investigated the efficacy of dual long-acting bronchodilator therapy delivered via the Respimat® SMI on lung function in patients with COPD stratified by inhalation ability. Tiotropium/olodaterol delivered via the SMI was effective both in patients with peak inspiratory flow (PIF) <60 L/min and PIF ≥60 L/min, measured against medium-low resistance. Methods This congress compilation summarizes post hoc analyses from the TRONARTO study presented at the annual American Thoracic Society 2022 and European Respiratory Society 2022 meetings. These analyses evaluated PIF in over 200 patients, with PIF measurements taken daily at home for 4 weeks, and in the clinic at baseline, Weeks 2 and 4. Results Overall, 57.9% of patients had a PIF range (difference between lowest and highest PIF measurements) <20 L/min (12.4% of patients had PIF range <10 L/min). At-home PIF range decreased over the study period, suggesting that inhaler training/repeated PIF measurements may help to make patients' inspiratory effort more consistent. Some patient characteristics correlated with lower PIF (female gender, shorter stature, more severe disease, worse airflow obstruction) and lower PIF range (more severe disease). PIF measurements differed between medium-low and high-resistance settings, highlighting the importance of measuring PIF at the resistance of a patient's inhaler. PIF correlated poorly with spirometry measurements. Conclusion As indicated in COPD management guidelines, choice of inhaler is essential to optimize pharmacologic therapies for COPD. Poor inspiratory ability should be viewed as a treatable trait that can help to inform inhaler choice. Inhaler training and consideration of PIF (if patients use a dry powder inhaler) can reduce patient-to-inhaler mismatch, with potential consequences for health status and exacerbation risk.
Collapse
Affiliation(s)
- Donald A Mahler
- Geisel School of Medicine at Dartmouth, Hanover, NH, USA
- Valley Regional Hospital, Claremont, NH, USA
| | - Henrik Watz
- Pulmonary Research Institute at LungenClinic Grosshansdorf, Grosshansdorf, Germany
| | | | | | - Asparuh Gardev
- Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany
| | - Asif Shaikh
- Boehringer Ingelheim Pharmaceuticals, Inc., Ridgefield, CT, USA
| | - M Bradley Drummond
- Pulmonary Diseases and Critical Care Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| |
Collapse
|
6
|
Trushenko NV, Stoliarevich AA, Andriukov BG, Nuralieva GS, Tsareva NA, Lavginova BB, Avdeev SN. [Assessment of inhalation technique in patients with bronchial asthma and chronic obstructive pulmonary disease]. TERAPEVT ARKH 2023; 95:210-216. [PMID: 37167141 DOI: 10.26442/00403660.2023.03.202151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Indexed: 05/13/2023]
Abstract
AIM Investigate inhalation techniques using different inhalers types and their effect on the course of disease. MATERIALS AND METHODS This cross-sectional study included 110 patients with asthma, chronic obstructive pulmonary disease using the inhaler at least one month. Inhaler errors performed during demonstration were evaluated for each patient and entered in the check-lists. We also collected information about co-morbidities, education, mMRC dyspnea score, rate of exacerbations, and performed spirometry. RESULTS 80.9% of patients used metered-dose inhaler, 20.9% - single-dose and 21.8% - multiple-dose dry powder inhaler, 22.7% - soft-mist inhaler. Inhaler errors were made by 80.9% patients. The mean number of mistakes in metered-dose inhaler use was 2±1.6, single-dose powder inhaler -1.5±1.3, multiple-dose dry powder inhaler - 1.25±1.4, soft-mist inhaler - 0.68±0.7 (р=0.003). Age, diagnosis, duration of disease, education level, inhalers usage by relatives have no influence on the inhalation technique. A number of errors was related to female gender (р=0.007) and usage of more than 2 inhalers (r=0.3, p=0.002), previous instruction about inhalation technique (r=0.3, p=0.001). On the other hand, there were correlations between the number of errors and degree of bronchial obstruction, asthma control, severity of dyspnea by mMRC score, exacerbation rate. CONCLUSION Patients with bronchoobstructive diseases perform many inhaler errors, that substantially influences the severity and course of asthma and chronic obstructive pulmonary disease.
Collapse
Affiliation(s)
- N V Trushenko
- Sechenov First Moscow State Medical University (Sechenov University)
- Federal Pulmonology Research Institute
| | | | - B G Andriukov
- Central State Medical Academy Presidential Administration
| | - G S Nuralieva
- Sechenov First Moscow State Medical University (Sechenov University)
- Federal Pulmonology Research Institute
| | - N A Tsareva
- Sechenov First Moscow State Medical University (Sechenov University)
- Federal Pulmonology Research Institute
| | - B B Lavginova
- Sechenov First Moscow State Medical University (Sechenov University)
| | - S N Avdeev
- Sechenov First Moscow State Medical University (Sechenov University)
- Federal Pulmonology Research Institute
| |
Collapse
|
7
|
Çakmaklı S, Özdemir A, Fırat H, Aypak C. An evaluation of the use of inhalers in asthma and chronic obstructive pulmonary disease. J Taibah Univ Med Sci 2023; 18:860-867. [PMID: 36852239 PMCID: PMC9957742 DOI: 10.1016/j.jtumed.2023.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 12/12/2022] [Accepted: 01/01/2023] [Indexed: 01/15/2023] Open
Abstract
Objectives Inhaled therapy is the treatment of choice for obstructive lung diseases such as asthma and chronic obstructive pulmonary disease (COPD). However, the maximum benefit from such therapy depends on the correct use of inhaler devices. In this study, our primary aim was to evaluate inhaler techniques in patients with asthma and COPD in order to identify common errors. In addition, we investigated the effect of various parameters on the rate of inhaler misuse. Methods We enrolled a total of 300 asthma/COPD patients, who presented at the Chest Diseases and Family Medicine Outpatient Clinics of a tertiary hospital located in Ankara, Turkey. We used a face-to-face survey that included questions about sociodemographic features and inhaler therapy. Subsequently, we requested patients to demonstrate how they use their inhalers and assessed their inhalation technique according to checklists. Results Of the 300 patients, 70.2% used their inhaler drugs incorrectly. The rate of misuse among metered dose inhaler (MDI) users was significantly higher than those using dry powder inhalers (DPIs) (77.6% vs 64%; p = 0.002). When DPI devices were analyzed, the rates of misuse were significantly higher in Handihaler users (p = 0.012) and Diskus inhaler users (p = 0.009) when compared to Sanohaler users. Gender, type of disease (asthma/COPD), duration of inhaler use, and duration of illness had no impact on the rate of misuse. However, an advanced age (>60 years old), a level of education lower than high school, and the use of MDI were all identified as factors associated with misuse. The most common mistake was 'failing to breath out before inhalation' for all types of devices (for MDI: 66.7%, and for DPI: 71.1-82.8%). Conclusions The rate of inhaler drug misuse was high. The identification of factors associated with misuse could provide information to implement appropriate actions to reduce the rates of misuse.
Collapse
Affiliation(s)
- Seçil Çakmaklı
- Department of Family Medicine, University of Health Sciences, Ankara Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey
| | - Ayşe Özdemir
- Department of Family Medicine, University of Health Sciences, Ankara Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey
| | - Hikmet Fırat
- Department of Pulmonary Diseases, University of Health Sciences, Ankara Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey
| | - Cenk Aypak
- Department of Family Medicine, University of Health Sciences, Ankara Dışkapı Yıldırım Beyazıt Training and Research Hospital, Ankara, Turkey,Corresponding address: Department of Family Medicine, University of Health Sciences, Ankara Dışkapı Yıldırım Beyazıt Training and Research Hospital, 06110, Ankara, Turkey.
| |
Collapse
|
8
|
Inhaler use in chronic obstructive pulmonary disease patients: a meta-analysis †. FRONTIERS OF NURSING 2022. [DOI: 10.2478/fon-2022-0044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Abstract
Objective: To evaluate errors in the use of inhalation techniques in patients with chronic obstructive pulmonary disease (COPD), and to provide evidence for improving the effectiveness of drugs.
Methods: A meta-analysis was performed after searching for literature at PubMed, Embase, Web of Science, Cochrane Library, CINAHL, China National Knowledge Infrastructure (CNKI), WanFang, VIP, and SionMed databases which were published from January 2011 to October 2020, addressing errors in the use of inhalation technologies for the treatment of COPD. After reviewing the literature, extracting pertinent information, and evaluating the risk of bias for the included studies, statistical analysis was performed using Stata 15.1.
Results: Thirteen papers (12 in English and 1 in Chinese), representing 2527 patients, met the search criteria and were included in the meta-analysis. The results showed that the combined effect size of COPD patients making at least one operational error was 76% (95% CI: 0.69–0.83). The error rate varied with inhaler type; the combined effect size error for powered inhalers was 66% (95% CI: 0.57, 0.74), 67% (95% CI. 0.57, 0.77) for metered-dose inhalers (MDI), and 51% (95% CI: 0.38, 0.64) for soft mist inhalers (SMI).
Conclusions: More than 75% of patients with COPD were unable to consistently use inhalers correctly, with the highest error rate for MDI. Therefore, health care providers must continue to educate patients on proper use of inhaler, ensuring their correct use and reducing the risk of acute COPD exacerbations.
Collapse
|
9
|
Mossadeq S, Shah R, Shah V, Bagul M. Formulation, Device, and Clinical Factors Influencing the Targeted Delivery of COVID-19 Vaccines to the Lungs. AAPS PharmSciTech 2022; 24:2. [PMID: 36416999 PMCID: PMC9684852 DOI: 10.1208/s12249-022-02455-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Accepted: 10/31/2022] [Indexed: 11/25/2022] Open
Abstract
The COVID-19 pandemic has proven to be an unprecedented health crisis in the human history with more than 5 million deaths worldwide caused to the SARS-CoV-2 and its variants ( https://www.who.int/emergencies/diseases/novel-coronavirus-2019 ). The currently authorized lipid nanoparticle (LNP)-encapsulated mRNA vaccines have been shown to have more than 90% vaccine efficacy at preventing COVID-19 illness (Baden et al. New England J Med 384(5):403-416, 2021; Thomas et al., 2021). In addition to vaccines, other small molecules belonging to the class of anti-viral and anti-inflammatory compounds have also been prescribed to reduce the viral proliferation and the associated cytokine storm. These anti-viral and anti-inflammatory compounds have also been shown to be effective in reducing COVID-19 exacerbations especially in reducing the host inflammatory response to SARS-CoV-2. However, all of the currently FDA-authorized vaccines for COVID-19 are meant for intramuscular injection directly into the systemic circulation. Also, most of the small molecules investigated for their anti-COVID-19 efficacy have also been explored using the intravenous route with a few of them explored for the inhalation route (Ramakrishnan et al. Lancet Respir Med 9:763-772, 2021; Horby et al. N Engl J Med 384(8):693-704, 2021). The fact that the SARS-CoV-2 enters the human body mainly via the nasal and airway route resulting in the lungs being the primary organs of infection as characterized by acute respiratory distress syndrome (ARDS)-mediated cytokine storm in the alveolar region has made the inhalation route gain significant attention for the purposes of targeting both vaccines and small molecules to the lungs (Mitchell et al., J Aerosol Med Pulm Drug Deliv 33(4):235-8, 2020). While there have been many studies reporting the safety and efficacy of targeting various therapeutics to the lungs to treat COVID-19, there is still a need to match the choice of inhalation formulation and the delivery device platform itself with the patient-related factors like breathing pattern and respiratory rate as seen in a clinical setting. In that perspective, this review aims to describe the various formulation and patient-related clinical factors that can play an important role in the judicious choice of the inhalation delivery platforms or devices for the development of inhaled COVID-19 vaccines.
Collapse
Affiliation(s)
- Sayeed Mossadeq
- Raptim Research Private Limited, 1378 Rt.206., STE 6/280, Skillman, NJ, 08558, USA.
| | - Rajen Shah
- Raptim Research Private Limited, 1378 Rt.206., STE 6/280, Skillman, NJ, 08558, USA
| | - Viraj Shah
- Raptim Research Private Limited, 1378 Rt.206., STE 6/280, Skillman, NJ, 08558, USA
| | - Milind Bagul
- Raptim Research Private Limited, 1378 Rt.206., STE 6/280, Skillman, NJ, 08558, USA
| |
Collapse
|
10
|
Lower Inspiratory Breathing Depth Enhances Pulmonary Delivery Efficiency of ProAir Sprays. Pharmaceuticals (Basel) 2022; 15:ph15060706. [PMID: 35745624 PMCID: PMC9227885 DOI: 10.3390/ph15060706] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 05/31/2022] [Accepted: 06/01/2022] [Indexed: 12/17/2022] Open
Abstract
Effective pulmonary drug delivery using a metered-dose inhaler (MDI) requires a match between the MDI sprays, the patient’s breathing, and respiratory physiology. Different inhalers generate aerosols with distinct aerosol sizes and speeds, which require specific breathing coordination to achieve optimized delivery efficiency. Inability to perform the instructed breathing maneuver is one of the frequently reported issues during MDI applications; however, their effects on MDI dosimetry are unclear. The objective of this study is to systemically evaluate the effects of breathing depths on regional deposition in the respiratory tract using a ProAir-HFA inhaler. An integrated inhaler mouth-throat-lung geometry model was developed that extends to the ninth bifurcation (G9). Large-eddy simulation (LES) was used to compute the airflow dynamics due to concurrent inhalation and orifice flows. The discrete-phase Lagrangian model was used to track droplet motions. Experimental measurements of ProAir spray droplet sizes and speeds were used as initial and boundary conditions to develop the computational model for ProAir-pulmonary drug delivery. The time-varying spray plume from a ProAir-HFA inhaler into the open air was visualized using a high-speed imaging system and was further used to validate the computational model. The inhalation dosimetry of ProAir spray droplets in the respiratory tract was compared among five breathing depths on a regional, sub-regional, and local basis. The results show remarkable differences in airflow dynamics within the MDI mouthpiece and the droplet deposition distribution in the oral cavity. The inhalation depth had a positive relationship with the deposition in the mouth and a negative relationship with the deposition in the five lobes beyond G9 (small airways). The highest delivery efficiency to small airways was highest at 15 L/min and declined with an increasing inhalation depth. The drug loss inside the MDI was maximal at 45–60 L/min. Comparisons to previous experimental and numerical studies revealed a high dosimetry sensitivity to the inhaler type and patient breathing condition. Considering the appropriate inhalation waveform, spray actuation time, and spray properties (size and velocity) is essential to accurately predict inhalation dosimetry from MDIs. The results highlight the importance of personalized inhalation therapy to match the patient’s breathing patterns for optimal delivery efficiencies. Further complimentary in vitro or in vivo experiments are needed to validate the enhanced pulmonary delivery at 15 L/min.
Collapse
|
11
|
W H Kocks J, Wouters H, Bosnic-Anticevich S, van Cooten J, Correia de Sousa J, Cvetkovski B, Dekhuijzen R, Dijk L, Dvortsin E, Garcia Pardo M, Gardev A, Gawlik R, van Geer-Postmus I, van der Ham I, Harbers M, de la Hoz A, Janse Y, Kerkhof M, Lavorini F, Maricoto T, Meijer J, Metz B, Price D, Roman-Rodriguez M, Schuttel K, Stoker N, Tsiligianni I, Usmani O, Leving MT. Factors associated with health status and exacerbations in COPD maintenance therapy with dry powder inhalers. NPJ Prim Care Respir Med 2022; 32:18. [PMID: 35618739 PMCID: PMC9135702 DOI: 10.1038/s41533-022-00282-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 05/10/2022] [Indexed: 01/25/2023] Open
Abstract
The study aimed to determine the associations of Peak Inspiratory Flow (PIF), inhalation technique and adherence with health status and exacerbations in participants with COPD using DPI maintenance therapy. This cross-sectional multi-country observational real-world study included COPD participants aged ≥40 years using a DPI for maintenance therapy. PIF was measured three times with the In-Check DIAL G16: (1) typical PIF at resistance of participant’s inhaler, (2) maximal PIF at resistance of participant’s inhaler, (3) maximal PIF at low resistance. Suboptimal PIF (sPIF) was defined as PIF lower than required for the device. Participants completed questionnaires on health status (Clinical COPD Questionnaire (CCQ)), adherence (Test of Adherence to Inhalers (TAI)) and exacerbations. Inhalation technique was assessed by standardised evaluation of video recordings. Complete data were available from 1434 participants (50.1% female, mean age 69.2 years). GOLD stage was available for 801 participants: GOLD stage I (23.6%), II (54.9%), III (17.4%) and IV (4.1%)). Of all participants, 29% had a sPIF, and 16% were shown able to generate an optimal PIF but failed to do so. sPIF was significantly associated with worse health status (0.226 (95% CI 0.107–0.346), worse units on CCQ; p = 0.001). The errors ‘teeth and lips sealed around mouthpiece’, ‘breathe in’, and ‘breathe out calmly after inhalation’ were related to health status. Adherence was not associated with health status. After correcting for multiple testing, no significant association was found with moderate or severe exacerbations in the last 12 months. To conclude, sPIF is associated with poorer health status. This study demonstrates the importance of PIF assessment in DPI inhalation therapy. Healthcare professionals should consider selecting appropriate inhalers in cases of sPIF.
Collapse
Affiliation(s)
- Janwillem W H Kocks
- General Practitioners Research Institute, Groningen, The Netherlands. .,University of Groningen, University Medical Center Groningen, GRIAC Research Institute, Groningen, The Netherlands. .,Observational and Pragmatic Research Institute, Singapore, Singapore. .,Department of Pulmonology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
| | - Hans Wouters
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Sinthia Bosnic-Anticevich
- Woolcock Institute of Medical Research, University of Sydney, Sydney, Australia.,Sydney Local Health District, Sydney, Australia
| | - Joyce van Cooten
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Jaime Correia de Sousa
- Life and Health Sciences Research Institute (ICVS), PT Government Associate Laboratory, School of Medicine, University of Minho, Braga, Portugal
| | - Biljana Cvetkovski
- Woolcock Institute of Medical Research, University of Sydney, Sydney, Australia
| | | | - Lars Dijk
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Evgeni Dvortsin
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Marina Garcia Pardo
- Primary Care Respiratory Research Unit, Instituto De Investigación Sanitaria De Baleares (IdISBa), Palma de Mallorca, Spain
| | - Asparuh Gardev
- Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany
| | - Radosław Gawlik
- Department of Internal Medicine, Allergology, Clinical Immunology, Medical University of Silesia, Katowice, Poland
| | | | - Iris van der Ham
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Marten Harbers
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Alberto de la Hoz
- Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany
| | - Ymke Janse
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Marjan Kerkhof
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Federico Lavorini
- Department of Clinical and Experimental Medicine, Careggi University Hospital, Florence, Italy
| | - Tiago Maricoto
- Faculty of Health Sciences, University of Beira Interior, Covilha, Portugal
| | - Jiska Meijer
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Boyd Metz
- General Practitioners Research Institute, Groningen, The Netherlands
| | - David Price
- Observational and Pragmatic Research Institute, Singapore, Singapore.,Centre of Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Aberdeen, UK
| | - Miguel Roman-Rodriguez
- Primary Care Respiratory Research Unit, Instituto De Investigación Sanitaria De Baleares (IdISBa), Palma de Mallorca, Spain
| | - Kirsten Schuttel
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Nilouq Stoker
- General Practitioners Research Institute, Groningen, The Netherlands
| | - Ioanna Tsiligianni
- Department of Social Medicine, Health Planning Unit, Faculty of Medicine, University of Crete, Rethymno, Greece
| | - Omar Usmani
- Airway Disease, National Heart and Lung Institute (NHLI), Imperial College London and Royal Brompton Hospital, London, UK
| | - Marika T Leving
- General Practitioners Research Institute, Groningen, The Netherlands
| |
Collapse
|
12
|
Lung Function Can Predict the Expected Inspiratory Airflow Rate through Dry Powder Inhalers in Asthmatic Adolescents. CHILDREN 2022; 9:children9030377. [PMID: 35327749 PMCID: PMC8947273 DOI: 10.3390/children9030377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/24/2022] [Accepted: 03/04/2022] [Indexed: 11/17/2022]
Abstract
Several factors affect drug delivery from dry powder inhalers (DPIs). Some are related to patient’s physiological characteristics, while others depend on DPIs’ technical aspects. The patient’s inspiratory airflow rate (IAR) affects the pressure drop and the turbulence needed to disaggregate the powder inside a DPI. The present study investigated whether lung function limitations occurring in asthmatic adolescents affect their IAR when inhaling through a DPI simulator. Eighteen consecutive adolescents with asthma were recruited, and IAR was randomly assessed at low-, mid-, and high-resistance regimens. A multiple logistic model was developed to evaluate the association of patients’ lung function characteristics and devices’ resistance with the probability to achieve the expected IAR (E-IAR). The mean value of E-IAR achieved seemed to be sex- and age-independent. Low- and high-resistance regimens were less likely to consent the E-IAR level (odds ratio [OR] = 0.035 and OR = 0.004, respectively). Only the basal residual volume and the inspiratory resistance, but not the Forced Expiratory Volume in 1 s (FEV1), seemed to affect the extent of IAR in asthmatic adolescents (OR = 1.131 and OR = 0.290, respectively). The results suggest that the assessment of current lung function is crucial for choosing the proper DPI for asthmatic adolescents.
Collapse
|
13
|
Ohar JA, Ferguson GT, Mahler DA, Drummond MB, Dhand R, Pleasants RA, Anzueto A, Halpin DMG, Price DB, Drescher GS, Hoy HM, Haughney J, Hess MW, Usmani OS. Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease. Int J Chron Obstruct Pulmon Dis 2022; 17:79-92. [PMID: 35023914 PMCID: PMC8747625 DOI: 10.2147/copd.s319511] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 10/25/2021] [Indexed: 12/03/2022] Open
Abstract
Dry powder inhalers (DPIs) are breath actuated, and patients using DPIs need to generate an optimal inspiratory flow during the inhalation maneuver for effective drug delivery to the lungs. However, practical and standardized recommendations for measuring peak inspiratory flow (PIF)—a potential indicator for effective DPI use in chronic obstructive pulmonary disease (COPD)—are lacking. To evaluate recommended PIF assessment approaches, we reviewed the Instructions for Use of the In-Check™ DIAL and the prescribing information for eight DPIs approved for use in the treatment of COPD in the United States. To evaluate applied PIF assessment approaches, we conducted a PubMed search from inception to August 31, 2021, for reports of clinical and real-life studies where PIF was measured using the In-Check™ DIAL or through a DPI in patients with COPD. Evaluation of collective sources, including 47 applicable studies, showed that instructions related to the positioning of the patient with their DPI, instructions for exhalation before the inhalation maneuver, the inhalation maneuver itself, and post-inhalation breath-hold times varied, and in many instances, appeared vague and/or incomplete. We observed considerable variation in how PIF was measured in clinical and real-life studies, underscoring the need for a standardized method of PIF measurement. Standardization of technique will facilitate comparisons among studies. Based on these findings and our clinical and research experience, we propose specific recommendations for PIF measurement to standardize the process and better ensure accurate and reliable PIF values in clinical trials and in daily clinical practice.
Collapse
Affiliation(s)
- Jill A Ohar
- Section of Pulmonary, Critical Care, Allergy, and Immunology, School of Medicine, Wake Forest University, Winston-Salem, NC, USA
| | - Gary T Ferguson
- Pulmonary Research Institute of Southeast Michigan, Farmington Hills, MI, USA
| | | | - M Bradley Drummond
- Division of Pulmonary Diseases and Critical Care Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
| | - Rajiv Dhand
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, USA
| | - Roy A Pleasants
- Division of Pulmonary Diseases and Critical Care Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.,Department of Quality, University of Michigan, Ann Arbor, MI, USA
| | - Antonio Anzueto
- Pulmonology Section, University of Texas Health, and South Texas Veterans Health Care System, San Antonio, TX, USA
| | - David M G Halpin
- University of Exeter Medical School, College of Medicine and Health, University of Exeter, Exeter, UK
| | - David B Price
- Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Aberdeen, UK.,Observational and Pragmatic Research Institute, Singapore
| | - Gail S Drescher
- Pulmonary Services Department, MedStar Washington Hospital Center, Washington, DC, USA
| | - Haley M Hoy
- Transplant Center, Vanderbilt University Medical Center, Nashville, TN, USA
| | - John Haughney
- Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Aberdeen, UK
| | | | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| |
Collapse
|
14
|
Leving M, Wouters H, de la Hoz A, Bosnic-Anticevich S, Dekhuijzen R, Gardev A, Lavorini F, Meijer J, Price D, Rodríguez MR, Tsiligianni I, Usmani O, Wijnsma B, Kocks J. Impact of PIF, Inhalation Technique and Medication Adherence on Health Status and Exacerbations in COPD: Protocol of a Real-World Observational Study (PIFotal COPD Study). Pulm Ther 2021; 7:591-606. [PMID: 34533772 PMCID: PMC8445793 DOI: 10.1007/s41030-021-00172-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 08/25/2021] [Indexed: 11/26/2022] Open
Abstract
INTRODUCTION Dry powder inhalers (DPIs), a commonly prescribed inhaler type for respiratory diseases, require patients to generate sufficient peak inspiratory flow (PIF) to ensure optimal drug delivery to the airways. Effectiveness of therapy also requires a good inhalation technique and adequate medication adherence. For patients with chronic obstructive pulmonary disease (COPD), recent studies conducted in tertiary care suggest that DPI users with suboptimal PIF have poorer COPD-related health status and increased exacerbation risk versus those with optimal PIF. The PIFotal study will investigate the impact of PIF, inhalation technique and medication adherence on patient-reported outcomes in patients with COPD in primary care using a DPI for their maintenance therapy. METHODS AND ANALYSIS This cross-sectional observational study will assess 1200 patients (aged ≥ 40 years, diagnosed with COPD and using a DPI for COPD maintenance therapy for ≥ 3 months) from the Netherlands, Spain, Portugal, Poland, Greece and Australia. Assessments will consist of (1) PIF measurements (usual patient inhalation manoeuvre, maximal PIF against resistance of own inhaler, and maximal PIF against low resistance); (2) Clinical COPD Questionnaire (CCQ), COPD Assessment Test and Test of Adherence to Inhalers scores; and (3) video recordings of patient inhalation technique. Dependent variables include health status (CCQ score), number of self-reported exacerbations in previous 12 months, and healthcare resource utilisation in previous 6 months. Independent variables include PIF values, inhalation technique errors, medication adherence, and demographic and clinical characteristics. In the primary analysis, the mean difference in CCQ score between patients (1) with optimal/suboptimal PIF, (2) exhibiting/not exhibiting inhalation technique errors, and (3) adhering/not adhering to medication will be examined in a multivariable linear mixed model. ETHICS The study protocol was approved by ethics committees/institutional review boards of all participating sites prior to enrolment; written informed consent was obtained from all study participants. TRIAL REGISTRATION NUMBER ClinicalTrials.gov: NCT04532853.
Collapse
Affiliation(s)
- Marika Leving
- General Practitioners Research Institute, Professor Enno Dirk Wiersmastraat 5, 9713 GH, Groningen, The Netherlands.
| | - Hans Wouters
- General Practitioners Research Institute, Professor Enno Dirk Wiersmastraat 5, 9713 GH, Groningen, The Netherlands
| | - Alberto de la Hoz
- Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany
| | - Sinthia Bosnic-Anticevich
- Woolcock Institute of Medical Research, University of Sydney, Sydney, Australia
- Sydney Local Health District, Sydney, Australia
| | | | - Asparuh Gardev
- Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany
| | - Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy
| | - Jiska Meijer
- General Practitioners Research Institute, Professor Enno Dirk Wiersmastraat 5, 9713 GH, Groningen, The Netherlands
| | - David Price
- Observational and Pragmatic Research Institute, Singapore, Singapore
- Division of Applied Health Sciences, Centre of Academic Primary Care, University of Aberdeen, Aberdeen, UK
| | - Miguel Román Rodríguez
- Primary Care Respiratory Research Unit, Instituto de Investigación Sanitaria de Baleares (IdISBa), Palma, Spain
| | - Ioanna Tsiligianni
- Health Planning Unit, Department of Social Medicine, Faculty of Medicine, University of Crete, Heraklion, Greece
| | - Omar Usmani
- National Heart and Lung Institute (NHLI), Imperial College London, London, UK
- Royal Brompton Hospital, London, UK
| | - Birgit Wijnsma
- General Practitioners Research Institute, Professor Enno Dirk Wiersmastraat 5, 9713 GH, Groningen, The Netherlands
| | - Janwillem Kocks
- General Practitioners Research Institute, Professor Enno Dirk Wiersmastraat 5, 9713 GH, Groningen, The Netherlands
- Observational and Pragmatic Research Institute, Singapore, Singapore
- University Medical Center Groningen, GRIAC Research Institute, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
15
|
Chawla R, Banerjee S, Yadav V, Chaudhary G, Chawla A. Impact of training on use of inhalational techniques of different inhaler devices: A single institutional cross sectional observation study. Indian J Tuberc 2021; 68:502-509. [PMID: 34752321 DOI: 10.1016/j.ijtb.2021.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Revised: 09/20/2020] [Accepted: 01/19/2021] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To assess the impact of training on use of inhalational techniques of different inhaler devices in spirometry proved cases of COPD and Bronchial Asthma in a tertiary care centre. METHODS A total of 128 spirometry proved cases of Asthma and COPD were enrolled. They were equally distributed in four groups comprising of 32 patients each according to their inhalation devices namely pMDI, Rotahaler, Accuhaler and Turbohaler. Patients were asked to demonstrate their inhalation technique and errors were noted according to their inhaler specific checklist. Patients were also interviewed regarding their knowledge about inhalation devices. Training about proper inhalation techniques was given to every participant. Rechecking of inhalation technique was again done at the second visit after 2 wks in the similar manner. Correct and incorrect steps of inhalation technique again evaluated by filling the checklist of the individual device to see post training improvement. RESULT In our study, out of total cases more than one third of the patients were >60 yrs of age (41.4%) and most of the patients were males (62.5%). During the interview at first visit, almost 92% patients claimed to know how to use the inhalation device correctly but in reality most of the patients (around 96.1%) had committed at least one mistakes in their inhalation technique among all the inhalation steps. Errors were noted in different steps of inhalation including the essential steps among all the four devices. Statistically significant improvement in inhalation techniques including the essential steps were found among all the four devices after educational intervention and demonstration of sequential steps involved in particular inhaler. CONCLUSION Our study confirmed a significant increase in the percentage of improvement in inhalation technique after proper demonstration and training about the inhalation devices. Inhalation technique including essential steps of inhalation significantly improved in all the four devices used.
Collapse
|
16
|
Mahler DA, Ludwig-Sengpiel A, Ferguson GT, de la Hoz A, Ritz J, Shaikh A, Watz H. TRONARTO: A Randomized, Placebo-Controlled Study of Tiotropium/Olodaterol Delivered via Soft Mist Inhaler in COPD Patients Stratified by Peak Inspiratory Flow. Int J Chron Obstruct Pulmon Dis 2021; 16:2455-2465. [PMID: 34511891 PMCID: PMC8414074 DOI: 10.2147/copd.s324467] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 08/12/2021] [Indexed: 12/04/2022] Open
Abstract
Background Inhaled bronchodilator therapy is currently the mainstay of treatment for patients with chronic obstructive pulmonary disease (COPD). Some inhalers require patients to achieve certain inhalation efforts either to activate the device or to deliver medication to the site of action. For dry powder inhalers, low peak inspiratory flow (PIF) can result in poor medication delivery but the clinical significance of this is not well understood. Methods TRONARTO was a 4-week, randomized, double-blind, placebo-controlled, multicenter, parallel-group study which stratified patients with moderate-to-severe COPD according to their PIF against medium-low resistance at screening. Patients were randomized to receive tiotropium/olodaterol (5 μg/5 μg) or matched placebo delivered via the Respimat® Soft Mist™ inhaler (SMI). After 4 weeks of treatment, we assessed change from baseline in forced expiratory volume in 1 second (FEV1) area under the curve 0–3 hours (FEV1 AUC0–3h) and trough FEV1. Results Overall, 213 patients were randomized, of whom 106 received tiotropium/olodaterol (PIF <60 L/min, 55; PIF ≥60 L/min, 51) and 107 received placebo (PIF <60 L/min, 55; PIF ≥60 L/min, 52). For FEV1 AUC0–3h, the adjusted mean change from baseline versus placebo was 336 mL (95% confidence interval [CI] 246–425 mL; P<0.0001) in the PIF <60 L/min group and 321 mL (95% CI 233–409 mL; P<0.0001) in the PIF ≥60 L/min group. For trough FEV1, the adjusted mean change from baseline versus placebo was 201 mL (95% CI 117–286 mL; P<0.0001) in the PIF <60 L/min group and 217 mL (95% CI 135–299 mL; P<0.0001) in the PIF ≥60 L/min group. Conclusion In the TRONARTO study, which included patients with moderate-to-severe COPD and varying inspiratory flow abilities, treatment with tiotropium/olodaterol resulted in significant lung function improvements versus placebo. This SMI can be used irrespective of the PIF that a patient can generate.
Collapse
Affiliation(s)
- Donald A Mahler
- Geisel School of Medicine at Dartmouth, Hanover, NH, USA.,Section of Pulmonary Medicine, Valley Regional Hospital, Claremont, NH, USA
| | | | - Gary T Ferguson
- Department of Medicine, Pulmonary Research Institute of Southeast Michigan, Farmington Hills, MI, USA
| | - Alberto de la Hoz
- Cardio-Metabolism and Respiratory, Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany
| | - John Ritz
- Biostatistics, Boehringer Ingelheim Pharmaceuticals, Inc., Ridgefield, CT, USA
| | - Asif Shaikh
- Clinical Development & Medical Affairs, Boehringer Ingelheim Pharmaceuticals, Inc., Ridgefield, CT, USA
| | - Henrik Watz
- Pulmonary Research Institute at LungenClinic Grosshansdorf, Airway Research Center North (ARCN), German Center for Lung Research (DZL), Grosshansdorf, Germany
| |
Collapse
|
17
|
Ding N, Zhang W, Wang Z, Bai C, He Q, Dong Y, Feng X, Zhang J, Gao S. Prevalence and Associated Factors of Suboptimal Daily Peak Inspiratory Flow and Technique Misuse of Dry Powder Inhalers in Outpatients with Stable Chronic Airway Diseases. Int J Chron Obstruct Pulmon Dis 2021; 16:1913-1924. [PMID: 34188467 PMCID: PMC8236256 DOI: 10.2147/copd.s311178] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 06/01/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The present study aimed to investigate the prevalence and associated factors of suboptimal daily peak inspiratory flow (PIF) and technical misuse of three commonly used dry powder inhalers (DPIs) in outpatients with stable chronic airway diseases. Patients and Methods Included in this study were 85 outpatients with stable asthma, chronic obstructive pulmonary disease (COPD), or asthma-COPD Overlap (ACO) and had previously used any of Turbuhaler® (TUR), Diskus® (DIS), HandiHaler® (HAN) between December 2018 and September 2019. The patient’s daily PIF against the resistance of a specific DPI and operation technique was investigated by two pharmacists by using In-Check DIAL G16 and a checklist. Results Of the 85 patients, the proportion of patients with a suboptimal daily PIF and technical misuse was 38.8% and 65.9%, respectively. In logistic regression, we observed that the factors that increase the risk for suboptimal daily PIF were age (OR=1.06) and combination with respiratory diseases (OR = 6.59). The factor that decreases the risk for misuse was the higher education level (OR =0.63). Conclusion Even if patients have received training at the time of initial prescription, the standardization of the use of DPIs by patients in our center was still unoptimistic. Age and combined with respiratory diseases were associated with suboptimal PIF. Higher education level decreased the incidence of technique misuse.
Collapse
Affiliation(s)
- Nan Ding
- Department of Pharmacy, First Affiliated Hospital of Naval Medical University (Changhai Hospital), Shanghai, People's Republic of China
| | - Wei Zhang
- Department of Pharmacy, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, People's Republic of China
| | - Zhuo Wang
- Department of Pharmacy, First Affiliated Hospital of Naval Medical University (Changhai Hospital), Shanghai, People's Republic of China
| | - Chong Bai
- Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Naval Medical University (Changhai Hospital), Shanghai, People's Republic of China
| | - Qian He
- Department of Health Statistics, Faculty of Health Service, Naval Medical University, Shanghai, People's Republic of China
| | - Yuchao Dong
- Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Naval Medical University (Changhai Hospital), Shanghai, People's Republic of China
| | - Xiumin Feng
- Department of Respiratory and Critical Care Medicine, Changji Branch of First Affiliated Hospital of Xinjiang Medical University, Xinjiang, People's Republic of China
| | - Jingxi Zhang
- Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Naval Medical University (Changhai Hospital), Shanghai, People's Republic of China
| | - Shen Gao
- Department of Pharmacy, First Affiliated Hospital of Naval Medical University (Changhai Hospital), Shanghai, People's Republic of China
| |
Collapse
|
18
|
Dal Negro RW, Turco P, Povero M. The contribution of patients' lung function to the inspiratory airflow rate achievable through a DPIs' simulator reproducing different intrinsic resistance rates. Multidiscip Respir Med 2021; 16:752. [PMID: 33953914 PMCID: PMC8077610 DOI: 10.4081/mrm.2021.752] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 03/24/2021] [Indexed: 11/28/2022] Open
Abstract
Background The performance of DPIs depends on several physiological (patient-dependent) and technological (device-dependent) factors. The inspiratory airflow rate is the only active force generated and operating in the system for inducing the required pressure drop and eliciting the resistance-induced turbulence needed to disaggregate the powder through the device. The present study aimed to investigate in the most prevalent respiratory disorders whether and at what extent the inspiratory airflow rate achievable when inhaling through a DPIs’ simulator reproducing different intrinsic resistance regimens (low, mid, and high resistance) is affected by peculiar changes in lung function and/or can be predicted by any specific lung function parameter. Methods The inspiratory airflow rate was assessed in randomized order by the In-Check DIAL G16 at low, mid, and high resistance regimens in a sample of consecutive subjects at recruitment. Independent predictors of the probability to achieve the expected inhalation airflow rate were investigated by means of a multivariate logistic regression model, specific to the disease. Results A total of 114 subjects were recruited (asthmatics n=30; COPD n=50, restrictive patients n=16, and normal subjects n=18). The mean values of the expected inspiratory airflow rate achieved proved significantly different within the groups (p<0.0001), independently of sex and age. In asthmatics and in COPD patients, the mid-resistance regimen proved highly associated with the highest mean values of airflow rates obtained. Low- and high-resistance regimens were significantly less likely to consent to achieve the expected level of inspiratory airflow rate (OR<1 in all comparisons). Restrictive patients performed the lowest airflow rates at the low-resistance regimen (p<0.01). Unlike FEV1, RV in asthmatics (OR=1.008); RV and IRaw in COPD (OR=0.587 and OR=0.901, respectively), and FIF and TLC in restrictive patients (OR=1.041, and OR=0.962, respectively) proved the only sensitive predictors of the inspiratory airflow rate achievable at the different resistive regimens. Conclusions The intrinsic resistive regimen of DPIs can play a critical role. The patients’ lung function profile also affects the extent of their inhalation airflow rate. Some specific lung function parameters (such as: FIF; RV; IRaw; TLC, but not FEV1) may be regarded as specific predictors in real-life. In order to optimize the DPI choice, further to the device’s technology, also the current patients’ lung function should be properly investigated and carefully assessed.
Collapse
Affiliation(s)
- Roberto W Dal Negro
- National Centre for Respiratory Pharmacoeconomics and Pharmacoepidemiology, Verona
| | - Paola Turco
- Research & Clinical Governance, Verona, Italy
| | | |
Collapse
|
19
|
Petite SE, Hess MW, Wachtel H. The Role of the Pharmacist in Inhaler Selection and Education in Chronic Obstructive Pulmonary Disease. J Pharm Technol 2021; 37:95-106. [PMID: 34752567 PMCID: PMC7953076 DOI: 10.1177/8755122520937649] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective: To review the role of pharmacists in educating and monitoring patients with chronic obstructive pulmonary disease (COPD) on inhalation technique. Data Sources: A PubMed search (January 2000 to May 2020) was performed using the following keywords and associated medical subject headings: adherence, chronic obstructive pulmonary disease/COPD, education, inhaler, pharmacist, and technique. Study Selection and Data Extraction: The search was conducted to identify English language articles highlighting the importance of correct inhaler technique in COPD management and benefits of pharmacist inhaler training such as improved adherence, quality of life (QoL), and disease control. Randomized controlled trials, retrospective studies, observational studies, systematic reviews, and meta-analysis reporting pharmacist training were included. Data Synthesis: This review summarizes that incorrect inhaler use negatively affects treatment outcomes, prognosis, and QoL. Pharmacists are in a unique position to educate and monitor patients with COPD on optimal inhaler technique and an individualized, multifactorial approach to COPD management involving pharmacists could provide cost-effective patient care and improve adherence and minimize inhaler misuse. Several strategies used by pharmacists can optimize patient inhaler use, such as face-to-face technique demonstrations, the "teach-back" method, telemonitoring, instructional videos, or informational leaflets. An individualized action plan involving education and regular monitoring of inhaler use further enhances optimal adherence and disease management. Conclusions: As pharmacists are easily accessible to both patients and health care providers, they are ideally placed to play an important role in the enhancement of education on, and continuous assessment of, optimal inhaler technique, thereby improving adherence, disease control, and QoL.
Collapse
Affiliation(s)
| | - Michael W. Hess
- WMed Health, Western Michigan University, Kalamazoo, MI, USA
| | - Herbert Wachtel
- Boehringer Ingelheim Pharma GmbH & Co KG, Ingelheim am Rhein, Germany
| |
Collapse
|
20
|
Basheti I, Mahboub B, Salameh L, Al-Ani M, Jairoun AA, Saddik B, Abu-Gharbieh E. Assessment of Novel Inhaler Technique Reminder Labels in Image Format on the Correct Demonstration of Inhaler Technique Skills in Asthma: A Single-Blinded Randomized Controlled Trial. Pharmaceuticals (Basel) 2021; 14:ph14020150. [PMID: 33673280 PMCID: PMC7918490 DOI: 10.3390/ph14020150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/07/2021] [Accepted: 02/08/2021] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Prevalence of asthma in the United Arab Emirates (UAE) is high, and training patients on correct inhaler technique is vital. OBJECTIVES To assess the effectiveness of inhaler technique labels incorporating the individual technique steps in image format on the retention of correct inhaler technique for patients with asthma living in the UAE and following inhaler training; secondly to investigate the effect of inhaler technique education using self-check pictorial labels on patients' overall asthma control. METHODS This single-blinded randomized controlled study was conducted in 2019 and followed consecutive recruitment of asthma patients visiting respiratory clinics at Rashid Hospital in Dubai. Patients were using a controller inhaler (Turbuhaler (TH), Accuhaler (ACC), or pressurized metered-dose inhaler (pMDI)). Following recruitment, patients were randomized into active group receiving educational intervention plus the inhaler label, and control group receiving educational intervention without the label. Patients were assessed at baseline and at one-month on their inhaler technique and asthma control. RESULTS Participants (n = 245; 93 = TH, 70 = ACC, 82 = pMDI) showed a significant difference between the groups at one-month for inhaler technique scores for TH (active 5.29 ± 1.86 vs. control = 24.4 ± 21.28), ACC (active = 3.99 ± 1.43 vs. control = 25.45 ± 22.57), and pMDI (active = 4.59 ± 0.10 vs. control = 120.55 ± 17.2), p < 0.001 for all. Asthma control for active group indicated significant improvements compared to control for TH and pMDI (p < 0.001 for both), but not ACC group (p = 0.087). CONCLUSIONS Retention of correct inhaler technique and improved asthma control can be enhanced by using a specialized inhaler technique label in image format.
Collapse
Affiliation(s)
- Iman Basheti
- Department of Clinical Pharmacy and Therapeutics, Faculty of Pharmacy, Applied Science Private University, P.O. Box 166, Amman 11931, Jordan;
| | - Bassam Mahboub
- Rashid Hospital, Dubai Health Authority, Dubai 4545, United Arab Emirates; (B.M.); (L.S.)
| | - Laila Salameh
- Rashid Hospital, Dubai Health Authority, Dubai 4545, United Arab Emirates; (B.M.); (L.S.)
- Sharjah Institute for Medical Research, University of Sharjah, Sharjah 27272, United Arab Emirates; (M.A.-A.); (B.S.)
| | - Mena Al-Ani
- Sharjah Institute for Medical Research, University of Sharjah, Sharjah 27272, United Arab Emirates; (M.A.-A.); (B.S.)
| | | | - Basema Saddik
- Sharjah Institute for Medical Research, University of Sharjah, Sharjah 27272, United Arab Emirates; (M.A.-A.); (B.S.)
- Department of Family and Community Medicine and Behavioral Sciences, College of Medicine, University of Sharjah, Sharjah 27272, United Arab Emirates
| | - Eman Abu-Gharbieh
- Department of Clinical Sciences, College of Medicine, University of Sharjah, Sharjah 27272, United Arab Emirates
- Correspondence: ; Tel.: +971-6-505-7289
| |
Collapse
|
21
|
Alvarez-Gutiérrez FJ, Gómez-Bastero Fernández A, Medina Gallardo JF, Campo Sien C, Rytilä P, Delgado Romero J. Preference for Easyhaler ® Over Previous Dry Powder Inhalers in Asthma Patients: Results of the DPI PREFER Observational Study. Patient Prefer Adherence 2021; 15:349-358. [PMID: 33628015 PMCID: PMC7897861 DOI: 10.2147/ppa.s295710] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 01/30/2021] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVE To study patient preference for and satisfaction with the Easyhaler® device and to assess ease of training and use of the inhaler in patients previously treated with a variety of dry powder inhalers (DPIs). METHODS We designed a non-interventional, cross-sectional, single-visit observational study of adult patients with persistent asthma referred to specialized care who had previously been treated with DPI inhalers for at least 3 months. Once clinical baseline data had been checked, patients filled in questionnaires on asthma control (GINA 2019), Feeling of Satisfaction with the Inhaler (FSI-10), and adherence (TAI and Morisky-Green questionnaires). Thereafter, all patients were trained in the use of Easyhaler. We assessed ease of use and satisfaction (FSI-10) with Easyhaler, as well as inhaler device preferences. RESULTS We recruited 502 patients (mean age, 50.2 ± 16.2 y; 63.1% female), of whom 485 were evaluable. In response to the main objective of the study, we compared the values of the self-completed adapted FSI-10, to measure satisfaction with the inhaler. A significantly higher score in each item of the questionnaire was recorded for Easyhaler. Overall, 38% of patients showed exclusive preference for Easyhaler (compared with 15% for the previous device) or were evenly matched in 46% of cases. CONCLUSION In the present study, Easyhaler achieved better patient ratings in terms of preference and satisfaction than previously used DPI devices. In order to improve asthma adherence strategies, patient preferences and device choice should be taken into account.
Collapse
Affiliation(s)
- Francisco Javier Alvarez-Gutiérrez
- Unidad de Asma, Hospital Universitario Virgen del Rocio, Sevilla, Spain
- Correspondence: Francisco Javier Alvarez-Gutiérrez Unidad de Asma, Hospital Universitario Virgen del Rocio, Av. Manuel Siurot, S/n, Sevilla, 41013, Spain Email
| | | | | | | | | | | |
Collapse
|
22
|
Ciciliani AM, Denny M, Langguth P, Voshaar T, Wachtel H. Lung Deposition Using the Respimat ® Soft Mist™ Inhaler Mono and Fixed-Dose Combination Therapies: An In Vitro/ In Silico Analysis. COPD 2020; 18:91-100. [PMID: 33302718 DOI: 10.1080/15412555.2020.1853091] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Tiotropium and olodaterol are mainstay treatments for chronic obstructive pulmonary disease (COPD) and yield important clinical improvements, especially when used in fixed-dose combination. Whilst previous studies have shown consistent delivery of tiotropium to the lungs with the Respimat® inhaler, no such study has been carried out for olodaterol or the components of their fixed-dose combination (TIO/OLO). Combining in vitro and in silico models, we measured the amount of drug retained in the mouth-throat area, entering the trachea and reaching the lung periphery. We applied a hybrid deposition model that considered the experimentally determined output of an Alberta throat model (in vitro - dose to lung) combined with a computational fluid dynamic model of the lungs (in silico). Regardless of the COPD breathing pattern, ≥50% of the nominal dose of either tiotropium, olodaterol, or TIO and OLO in the fixed-dose combination reached the lung. Of the dose reaching the lungs, greater than 50% is deposited in the lung periphery (from generation 8 onwards). Our study demonstrated that aerosol delivery via the Respimat inhaler achieved high deposition deep into the lung periphery with all formulations evaluated.
Collapse
Affiliation(s)
- Anna-Maria Ciciliani
- Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, Mainz, Germany
| | - Mark Denny
- Respiratory Drug Delivery, Boehringer Ingelheim Pharma GmbH & Co. KG, Ingelheim am Rhein, Germany
| | - Peter Langguth
- Institute of Pharmacy and Biochemistry, Johannes Gutenberg University Mainz, Mainz, Germany
| | | | - Herbert Wachtel
- Analytical Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Ingelheim am Rhein, Germany
| |
Collapse
|
23
|
Principe S, Battaglia S, Benfante A, Arena C, Scichilone N. Does the frequency of switching inhalers represent a predictive factor of exacerbation in asthma? J Asthma 2020; 59:370-377. [PMID: 33252290 DOI: 10.1080/02770903.2020.1850766] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE Management of asthma includes monitoring of inhaler technique and level of adherence to treatment. Both factors could be influenced by high frequency of switching inhaler devices. We explored whether switching inhalers is an independent predictive factor of exacerbations. METHODS Data were collected from 2015 to 2017 from the outpatient clinic of asthma at the University of Palermo, Italy. This observational study consisted of two phases: Phase 1 included subjects of at least three visits in the previous year who reported the frequency of inhalers switched; Phase 2 included subjects of at least two visits during the second year, and the rate of switches and exacerbations was recorded. We included adult (24-84 years old) mild/moderate asthmatics under regular inhaled treatment; uncontrolled asthma was defined as poor symptom control, exacerbations (≥2/year) requiring oral corticosteroids (OCS), or serious exacerbations (≥1/year) requiring hospitalization. RESULTS A total of 109 records were retrieved for the analysis. A significant correlation between the rate of switches in Phase 1 and exacerbations in Phase 2 was found (p = 0.001). Age and the rates of exacerbations in Phase 1 were also independently associated with a higher number of exacerbations in Phase 2 (p < 0.0001). The multivariate regression model showed that the numbers of switches, as well as exacerbations in Phase 1, were independently correlated to the number of exacerbations in Phase 2 (p = 0.003). CONCLUSIONS The frequency of switching inhalers independently affects the risk of exacerbations in asthma. These results imply that changing inhaler requires careful management in clinical practice.
Collapse
Affiliation(s)
- Stefania Principe
- Dipartimento Universitario di Promozione della Salute, Materno Infantile, Medicina Interna e Specialistica di Eccellenza "G. D'Alessandro" (PROMISE), Division of Respiratory Medicine, "Paolo Giaccone" University Hospital, University of Palermo, Palermo, Italy
| | - Salvatore Battaglia
- Dipartimento Universitario di Promozione della Salute, Materno Infantile, Medicina Interna e Specialistica di Eccellenza "G. D'Alessandro" (PROMISE), Division of Respiratory Medicine, "Paolo Giaccone" University Hospital, University of Palermo, Palermo, Italy
| | - Alida Benfante
- Dipartimento Universitario di Promozione della Salute, Materno Infantile, Medicina Interna e Specialistica di Eccellenza "G. D'Alessandro" (PROMISE), Division of Respiratory Medicine, "Paolo Giaccone" University Hospital, University of Palermo, Palermo, Italy
| | - Cinzia Arena
- Dipartimento Universitario di Promozione della Salute, Materno Infantile, Medicina Interna e Specialistica di Eccellenza "G. D'Alessandro" (PROMISE), Division of Respiratory Medicine, "Paolo Giaccone" University Hospital, University of Palermo, Palermo, Italy
| | - Nicola Scichilone
- Dipartimento Universitario di Promozione della Salute, Materno Infantile, Medicina Interna e Specialistica di Eccellenza "G. D'Alessandro" (PROMISE), Division of Respiratory Medicine, "Paolo Giaccone" University Hospital, University of Palermo, Palermo, Italy
| |
Collapse
|
24
|
Himes BE, Leszinsky L, Walsh R, Hepner H, Wu AC. Mobile Health and Inhaler-Based Monitoring Devices for Asthma Management. THE JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE 2020; 7:2535-2543. [PMID: 31706485 DOI: 10.1016/j.jaip.2019.08.034] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 08/22/2019] [Accepted: 08/23/2019] [Indexed: 12/16/2022]
Abstract
Mobile health and web applications (apps), wearables, and other personal monitoring devices have tremendous potential to improve the management of asthma. More than 500 asthma-related apps, whether standalone or paired with sensors on inhalers, are currently available for health education, symptom recording, tracking of inhaler use, displaying environmental alerts, and providing medication reminders. Benefits of these tools include the ability to longitudinally collect symptom, trigger, and inhaler usage data, allowing the detection of significant changes over time to help patients and their caregivers determine whether symptoms are worsening. In addition, data from external information sources, including weather, allergen, and air quality reports, can be integrated with user-specific data to enhance predictions on when patients may experience symptoms and/or need to avoid triggers. Barriers to adoption of asthma-related apps and inhaler-based devices include uncertain efficacy and effectiveness, potential high cost, sustained user engagement, and concerns about privacy. Moreover, ensuring the acceptability and utility of asthma management apps for individuals of all races/ethnicities, socioeconomic groups, ages, genders, and literacy levels is necessary. Based on studies thus far, mobile health apps and inhaler-based devices have great potential to serve as useful tools in the patient-doctor relationship and revolutionize asthma care.
Collapse
Affiliation(s)
- Blanca E Himes
- Department of Biostatistics, Epidemiology and Informatics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pa.
| | - Lena Leszinsky
- Department of Biostatistics, Epidemiology and Informatics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pa
| | - Ryan Walsh
- Center for Healthcare Research in Pediatrics (CHeRP) and PRecisiOn Medicine Translational Research (PROMoTeR) Center, Department of Population Medicine, Harvard Pilgrim Health Care Institute and Harvard Medical School, Boston, Mass
| | - Hannah Hepner
- Center for Healthcare Research in Pediatrics (CHeRP) and PRecisiOn Medicine Translational Research (PROMoTeR) Center, Department of Population Medicine, Harvard Pilgrim Health Care Institute and Harvard Medical School, Boston, Mass
| | - Ann Chen Wu
- Center for Healthcare Research in Pediatrics (CHeRP) and PRecisiOn Medicine Translational Research (PROMoTeR) Center, Department of Population Medicine, Harvard Pilgrim Health Care Institute and Harvard Medical School, Boston, Mass
| |
Collapse
|
25
|
ElKasabgy NA, Adel IM, Elmeligy MF. Respiratory Tract: Structure and Attractions for Drug Delivery Using Dry Powder Inhalers. AAPS PharmSciTech 2020; 21:238. [PMID: 32827062 DOI: 10.1208/s12249-020-01757-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 07/13/2020] [Indexed: 12/26/2022] Open
Abstract
Respiratory tract is one of the oldest routes for drug delivery. It can be used for local and systemic drug deliveries. Inhalation therapy has several advantages over oral. It delivers the drug efficiently to the lung with minimal systemic exposure, thus avoiding systemic side effects common with oral route. In this review, different types of inhaler devices are illustrated like metered dose inhalers (MDIs), dry powder inhalers (DPIs), nebulizers, and the new soft mist inhalers (SMIs). Since dry powder is more stable than when in liquid form, we will discuss in detail DPIs highlighting different techniques utilized in preparation of dry powders with or without carrier to improve flowability and drug delivery to deep lungs. Types of DPIs are briefly discussed with examples from the market. Several mechanisms for particle deposition are mentioned with factors governing the process. Pharmacokinetic profile of the inhaled particles is detailed starting from the dissolution, followed by the rapid absorption and ending with systemic clearance. New technologies like 3D printing in pulmonary field are also highlighted.
Collapse
|
26
|
Zhang W, Xu L, Gao S, Ding N, Shu P, Wang Z, Li Y. Technical Evaluation of Soft Mist Inhaler Use in Patients with Chronic Obstructive Pulmonary Disease: A Cross-Sectional Study. Int J Chron Obstruct Pulmon Dis 2020; 15:1471-1479. [PMID: 32606655 PMCID: PMC7319532 DOI: 10.2147/copd.s253338] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Accepted: 05/22/2020] [Indexed: 11/23/2022] Open
Abstract
Background Proper inhaler technique is highly relevant to the effective management of chronic obstructive pulmonary disease (COPD). The tiotropium bromide spray (TBS) (Spiriva® Respimat®) is a soft mist inhaler (SMI) preferred by patients to pressurized metered-dose inhalers (pMDIs) and dry powder inhalers (DPIs) because of its convenience in use. However, the technique of using TBS inhaler in the real world is unclear. Objective To evaluate techniques in using TBS inhaler and investigate the association between the patient characteristics and the correct use of TBS inhaler. Methods This cross-sectional study enrolled 74 COPD patients who used TBS inhaler device for more than 3 months. The sociodemographic and clinical characteristics of the patients were recorded. The technique of using TBS inhaler was evaluated step by step. Incorrect use was defined as the patient’s inability to complete the key steps in the inhalation manoeuvre. The percentage of incorrect use was compared between the groups. Risk factors related to incorrect use were analyzed by logistic regression analysis. Results Of the 74 participants, only 2 (2.7%) patients completed all the steps correctly, and 48 (64.9%) patients misused the key steps in the inhalation manoeuvre. Incorrect preparation of the TBS inhaler for the first use was the most frequently misused step, accounting for 77.0%. Factors associated with misuse of TBS inhaler included the educational background (p=0.010), living state (p=0.031) and COPD assessment test (CAT) score (p=0.005) of the patients. Additionally, logistic regression analysis showed that the COPD duration was significantly associated with the incorrect use (p=0.019). Compared with patients with a higher educational background, patients with an elementary school background [OR 11652.99, CI: 22.72–5975697.72], junior high school background [OR 7187.78, CI: 16.41–3146787] and high school background [OR 1563, CI: 4.27–572329.67] were more likely to misuse TBS inhaler. Patients living with their spouses alone were also more likely to commit errors in using TBS inhaler as compared with those living with their children [OR 12.29, CI of 1.14–1.96]. Clinical factors like the COPD symptoms were relative to the technical use of the device. Better technique was accompanied by a lower CAT score [OR 1.49, CI of 1.14–1.96]. Conclusion The incorrect use of TBS inhaler was common in COPD patients. Healthcare providers should not only teach the patients about the drug preparation but help them use the inhaler correctly. Special attention should be paid to patients with a short COPD duration and a low educational background and those who live without the company of their children. Proper use of TBS inhaler can significantly improve the symptom control of COPD patients.
Collapse
Affiliation(s)
- Wei Zhang
- Department of Pharmacy, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai 200433, People's Republic of China
| | - Lili Xu
- Department of Pharmacy, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai 200433, People's Republic of China
| | - Shen Gao
- Department of Pharmacy, Changhai Hospital Affiliated to The Second Military Medical University, Shanghai 200433, People's Republic of China
| | - Nan Ding
- Department of Pharmacy, Changhai Hospital Affiliated to The Second Military Medical University, Shanghai 200433, People's Republic of China
| | - Ping Shu
- Department of Pharmacy, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai 200433, People's Republic of China
| | - Zhuo Wang
- Department of Pharmacy, Changhai Hospital Affiliated to The Second Military Medical University, Shanghai 200433, People's Republic of China
| | - Yuping Li
- Department of Pharmacy, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai 200433, People's Republic of China
| |
Collapse
|
27
|
Larsson K, Kankaanranta H, Janson C, Lehtimäki L, Ställberg B, Løkke A, Høines K, Roslind K, Ulrik CS. Bringing asthma care into the twenty-first century. NPJ Prim Care Respir Med 2020; 30:25. [PMID: 32503985 PMCID: PMC7275071 DOI: 10.1038/s41533-020-0182-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 04/21/2020] [Indexed: 12/16/2022] Open
Abstract
Despite access to diagnostic tests and effective therapies, asthma often remains misdiagnosed and/or poorly controlled or uncontrolled. In this review, we address the key issues of asthma diagnosis and management, recent evidence for levels of asthma control, the consequences of poor control and, in line with that, explore the potential reasons for poor asthma control and acute exacerbations. Based on recent evidence and current guidelines, we also aim to provide practical answers to the key questions of how to improve asthma management, with the best possible prevention of exacerbations, addressing the basics-adherence, inhaler misuse, obesity and smoking-and how to facilitate a new era of asthma care in the twenty-first century. We hope this review will be useful to busy primary care clinicians in their future interactions with their patients with both suspected and proven asthma.
Collapse
Affiliation(s)
- Kjell Larsson
- Integrative Toxicology, National Institute of Environmental Medicine, IMM, Karolinska Institute, Stockholm, Sweden.
| | - Hannu Kankaanranta
- Department of Respiratory Medicine, Seinäjoki Central Hospital, Seinäjoki, Finland
- Faculty of Medicine and Health Technology, University of Tampere, Tampere, Finland
| | - Christer Janson
- Department of Medical Sciences: Respiratory, Allergy and Sleep Research, Uppsala University, Uppsala, Sweden
| | - Lauri Lehtimäki
- Faculty of Medicine and Health Technology, University of Tampere, Tampere, Finland
- Allergy Centre, Tampere University Hospital, Tampere, Finland
| | - Björn Ställberg
- Department of Public Health and Caring Sciences, Family Medicine and Preventive Medicine, Uppsala University, Uppsala, Sweden
| | - Anders Løkke
- Department of Medicine, Little Belt Hospital, Vejle, Denmark
| | | | | | - Charlotte Suppli Ulrik
- Respiratory Research Unit Hvidovre, Department of Respiratory Medicine, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark
- Institute of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
28
|
Perumal R, Leite M, van Zyl-Smit RN. The Relationship Between Clinical Trial Participation and Inhaler Technique Errors in Asthma and COPD Patients. Int J Chron Obstruct Pulmon Dis 2020; 15:1217-1224. [PMID: 32581528 PMCID: PMC7277230 DOI: 10.2147/copd.s249620] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Background Incorrect inhaler use is associated with poorer health outcomes, reduced quality of life, and higher healthcare utilisation in patients with asthma and COPD. Methods We performed an observational study of pressurized metered-dose inhaler technique in patients with asthma or COPD. Patients were assessed using a six-point inhaler checklist to identify common critical inhaler technique errors. An inadequate inhaler technique was defined as the presence of one or more critical errors. A multivariate logistic regression model was used to determine the odds of an inadequate inhaler technique. Results During the 14-month study period, 357 patients were enrolled. At least one critical error was executed by 66.7% of participants, and 24.9% made four or more critical errors. The most common errors were failure to exhale completely prior to pMDI activation and inhalation (49.6%), failure to perform a slow, deep inhalation following device activation (48.7%), and failure to perform a breath-hold at the end of inspiration (47.3%). The risk of a critical error was higher in COPD patients (aOR 2.25, 95% CI 1.13-4.47). Prior training reduced error risk specifically when trained by a doctor (aOR 0.08, 95% CI 0.1-0.57) or a pharmacist (aOR 0.02, 95% CI 0.01-0.26) compared to those with no training. Previous clinical trial participation significantly reduced error risk and rate: <3 trials (aOR 0.35, 95% CI 0.19-0.66) and ≥3 trials (aOR 0.17, 95% CI 0.07-0.42). The rate of critical errors was not significantly associated with age, sex, or prior pMDI experience. Conclusion This study found a high rate of critical inhaler technique errors in a mixed population of asthma and COPD patients; however, prior training and, in particular, multiple previous clinical trial participation significantly reduced the risk of errors.
Collapse
Affiliation(s)
- Rubeshan Perumal
- Division of Pulmonology, Department of Medicine, Faculty of Health Sciences, University of Cape Town, Western Cape, South Africa
| | - Marcia Leite
- UCT Lung Institute, University of Cape Town, Western Cape, South Africa
| | - Richard Nellis van Zyl-Smit
- Division of Pulmonology, Department of Medicine, Faculty of Health Sciences, University of Cape Town, Western Cape, South Africa
- UCT Lung Institute, University of Cape Town, Western Cape, South Africa
| |
Collapse
|
29
|
Navaie M, Dembek C, Cho-Reyes S, Yeh K, Celli BR. Device use errors with soft mist inhalers: A global systematic literature review and meta-analysis. Chron Respir Dis 2020; 17:1479973119901234. [PMID: 31984767 PMCID: PMC6985977 DOI: 10.1177/1479973119901234] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 12/28/2019] [Indexed: 11/30/2022] Open
Abstract
Inhaled bronchodilators are the cornerstone of treatment for chronic obstructive pulmonary disease (COPD). Soft mist inhalers (SMIs) are devices that deliver bronchodilators. Although correct device use is paramount to successful medication delivery, patient errors are common. This global systematic literature review and meta-analysis examined device use errors with SMIs among patients with obstructive lung diseases. PubMed, EMBASE, PsycINFO, Cochrane, and Google Scholar were searched to identify studies published between 2010 and 2019 that met the following inclusion criteria: (a) English language; (b) a diagnosis of COPD, bronchitis, or emphysema; and (c) reported device use errors among adults receiving long-acting bronchodilator treatment with Respimat® SMI (i.e. Spiriva®, Stiolto®, Spiolto®, and Striverdi®). Descriptive statistics examined sociodemographics, clinical characteristics, and device use errors. Meta-analysis techniques were employed with random-effects models to generate pooled mean effect sizes and 95% confidence intervals (CIs) for overall and step-by-step errors. The I2 statistic measured heterogeneity. Twelve studies (n = 1288 patients) were included in this meta-analysis. Eighty-eight percent of patients had COPD, and most had moderate/very severe airflow limitation (Global Initiative for Chronic Obstructive Lung Disease spirometric stages II to IV). Aggregate results revealed that 58.9% (95% CI: 42.4-75.5; I2 = 92.8%) of patients made ≥1 device use errors. Among 11 studies with step-by-step data, the most common errors were failure to (1) exhale completely and away from the device (47.8% (95% CI: 33.6-62.0)); (2) hold breath for up to 10 seconds (30.6% (95% CI: 17.5-43.7)); (3) take a slow, deep breath while pressing the dose release button (27.9% (95% CI: 14.5-41.2)); (4) hold the inhaler upright (22.6% (95% CI: 6.2-39.0)); and (5) turn the base toward the arrows until it clicked (17.6% (95% CI: 3.0-32.2)). Device use errors occurred in about 6 of 10 patients who used SMIs. An individualized approach to inhalation device selection and ongoing training and monitoring of device use are important in optimizing bronchodilator treatment.
Collapse
Affiliation(s)
- Maryam Navaie
- Advance Health Solutions, LLC, New York, NY, USA
- School of Professional Studies, Columbia University, New York, NY, USA
| | - Carole Dembek
- Global Health Economics and Outcomes Research, Sunovion Pharmaceuticals Inc., Marlborough, MA, USA
| | | | - Karen Yeh
- Advance Health Solutions, LLC, New York, NY, USA
| | - Bartolome R Celli
- Chronic Obstructive Pulmonary Disease Center, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
30
|
Mahler DA. The role of inspiratory flow in selection and use of inhaled therapy for patients with chronic obstructive pulmonary disease. Respir Med 2019; 161:105857. [PMID: 32056720 DOI: 10.1016/j.rmed.2019.105857] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 12/11/2019] [Accepted: 12/27/2019] [Indexed: 11/26/2022]
Abstract
Inhalation therapy is the mainstay of chronic obstructive pulmonary disease management, and inhaler selection can have a profound impact on drug delivery and medication adherence, as well as on treatment outcomes. Although multiple delivery systems, such as pressurized metered-dose inhalers, dry powder inhalers, slow-mist inhalers, and nebulizers, are available, clinical benefits achieved by patients rely on effective delivery of the inhaled medication to the airways. Among several factors influencing drug deposition, inspiratory flow is one of the most important. Inspiratory flow impacts drug delivery and subsequent clinical efficacy, making it necessary to adequately train patients to ensure correct inhaler use. Peak inspiratory flow is the maximal airflow generated during a forced inspiratory maneuver. Health care professionals need to select the appropriate delivery system after carefully considering patient characteristics, including lung function, optimal inspiratory flow, manual dexterity, and cognitive function. Herein, the role of inspiratory flow in the selection and use of inhaled therapy in patients with COPD is reviewed.
Collapse
Affiliation(s)
- Donald A Mahler
- Emeritus Professor of Medicine, Geisel School of Medicine at Dartmouth, One Rope Ferry Road, Hanover, NH, 03755, USA; Valley Regional Hospital, Kane Center, 243 Elm Street, Claremont, NH, 03743, USA.
| |
Collapse
|
31
|
Abstract
Breathlessness is a common symptom for patients with terminal illness and can be challenging to manage. Breathlessness is acknowledged to be an interaction between body and mind. There are a variety of pharmacological and non-pharmacological therapies that can be beneficial. The holistic assessment of the breathlessness patient should enable delivery of a tailored package of care focused on relief of symptoms.
Collapse
Affiliation(s)
- Suzie Gillon
- Consultant in Palliative Medicine, Department of Palliative Care, St James's University Hospital, Leeds LS9 7TF
| | - Ian J Clifton
- Consultant in Respiratory Medicine, Department of Respiratory Medicine, St James's University Hospital, Leeds
| |
Collapse
|
32
|
Ahn JH, Chung JH, Shin KC, Choi EY, Jin HJ, Lee MS, Nam MJ, Lee KH. Critical Inhaler Handling Error Is an Independent Risk Factor for Frequent Exacerbations of Chronic Obstructive Pulmonary Disease: Interim Results of a Single Center Prospective Study. Int J Chron Obstruct Pulmon Dis 2019; 14:2767-2775. [PMID: 31819409 PMCID: PMC6896926 DOI: 10.2147/copd.s234774] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Accepted: 11/21/2019] [Indexed: 12/02/2022] Open
Abstract
Objective Chronic obstructive pulmonary disease (COPD) acute exacerbations are significant causes of morbidity and mortality. “Frequent exacerbator” phenotypes are considered a distinct subgroup and this phenotype has a negative effect on lung function, quality of life, activity, hospital admission, and mortality. We assess inhaler handling technique and adherence, and evaluate risk factors associated with frequent exacerbations in COPD patients. Methods This study was a cross-sectional, case-control study. We prospectively enrolled 189 COPD patients from Yeungnam University Hospital from January 2018 to November 2018. Subjects were tested regarding their inhaler technique in face-to-face interviews with an advanced practice nurse of inhaler upon study entry. Frequency of moderate to severe COPD exacerbations were reviewed via electronic medical records during 12 months prior to study entry. Frequent exacerbations were defined as ≥2 moderate to severe exacerbations in the prior 12 months. Multivariate logistic regression was performed to identify risk factors for frequent exacerbations. Results Among 189 COPD patients, 50 (26.5%) were frequent exacerbators. Based on univariate analyses, body mass index (BMI) < 25 kg/m2, lower forced expiratory volume in 1 s (FEV1), higher mMRC, lower feeling of satisfaction with the inhaler, and any critical errors were potential risk factors for frequent exacerbations. Multivariate logistic regression analyses revealed that BMI < 25 kg/m2 (OR, 2.855, 95% CI, 1.247–6.534; p=0.013), higher mMRC (OR, 1.625, 95% CI, 1.072–2.463; p=0.022), and any critical error (OR, 2.020, 95% CI, 1.021–3.999; p=0.044) were risk factors. Conclusion Any critical error, BMI < 25 kg/m2 and high mMRC are independent risk factors for frequent exacerbations in COPD patients. Careful monitoring and education around inhaler devices, particularly in frequent exacerbators, are important components of COPD treatment.
Collapse
Affiliation(s)
- June Hong Ahn
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| | - Jin Hong Chung
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| | - Kyeong-Cheol Shin
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| | - Eun Young Choi
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| | - Hyun Jung Jin
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| | - Mi Suk Lee
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| | - Mi Jeong Nam
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| | - Kwan Ho Lee
- Division of Pulmonology and Allergy, Department of Internal Medicine, Yeungnam University Medical Center, College of Medicine, Yeungnam University, Daegu, South Korea
| |
Collapse
|
33
|
Ortsäter G, Borgström F, Soulard S, Miltenburger C. A Budget Impact Model to Estimate the Environmental Impact of Adopting RESPIMAT ® Re-usable in the Nordics and Benelux. Adv Ther 2019; 36:3435-3445. [PMID: 31625130 PMCID: PMC6860470 DOI: 10.1007/s12325-019-01114-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Indexed: 11/25/2022]
Abstract
Introduction The healthcare sector contributes 5–8% of the global greenhouse gas emissions. Global and regional organizations and governments have started to design and implement measures to reduce global greenhouse gas emissions in the healthcare sector, e.g. by green public procurement policies and inclusion of ecological considerations in the decision-making process for purchasing and funding of healthcare technologies. The objective of this study was to perform budget impact analysis of adopting RESPIMAT re-usable in the Nordics and Benelux that considered both the traditional healthcare costs as well as the environmental impact. Methods Inhaler costs and environmental impact over 5 years in the Nordics and Benelux in a scenario with RESPIMAT re-usable compared to a scenario without RESPIMAT re-usable were estimated using an budget impact model. RESPIMAT re-usable enables patients to re-use the inhaler device and its availability therefore reduces the number of inhalers and associated wastage. The carbon emissions were derived for each treatment pattern considering the whole life cycle (cradle-to-grave) of the inhaler product. The cost of carbon emissions was estimated using a societal cost per ton of carbon emission. Results Progressively introducing RESPIMAT re-usable in the Nordics and Benelux was estimated to decrease the number of inhalers used by 2023 by 7,466,621 compared to a scenario without RESPIMAT re-usable, which would result in a reduction of the environmental burden of inhaler use of 4717 tCO2e and a decrease in societal cost of €205,888. Conclusions Adopting RESPIMAT re-usable would lead to a substantial reduction in CO2 emissions, leading to savings from a societal perspective. Funding Boehringer Ingelheim. Electronic supplementary material The online version of this article (10.1007/s12325-019-01114-1) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
| | - Fredrik Borgström
- Quantify Research, Stockholm, Sweden
- LIME/MMC, Karolinska Institutet, Stockholm, Sweden
| | | | | |
Collapse
|
34
|
Adult asthma: Diagnosis and treatment. Nurse Pract 2019; 42:16-24. [PMID: 28957947 DOI: 10.1097/01.npr.0000525716.32405.eb] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Adult asthma is a prevalent chronic medical condition that is associated with high morbidity, mortality, and cost. Early identification, evidence-based diagnosis, and step-wise management can lead to improvements in patient outcomes, decrease exacerbations, and eliminate respiratory function decline as the patient ages.
Collapse
|
35
|
McKiernan AP. Inhaler Spray Investigation Using High-Speed Phase-Contrast X-Ray and Schlieren Imaging. Pharm Res 2019; 36:120. [DOI: 10.1007/s11095-019-2657-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 06/10/2019] [Indexed: 10/26/2022]
|
36
|
Duarte-de-Araújo A, Teixeira P, Hespanhol V, Correia-de-Sousa J. COPD: misuse of inhaler devices in clinical practice. Int J Chron Obstruct Pulmon Dis 2019; 14:1209-1217. [PMID: 31213798 PMCID: PMC6549399 DOI: 10.2147/copd.s178040] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 10/25/2018] [Indexed: 01/08/2023] Open
Abstract
Background and objectives: Inhalers mishandling remain an important clinical issue worldwide. The aim of this study was to evaluate inhalation technique in stable COPD out-patients. The variables under study were type of inhaler device (ID), patients’ preference for an inhaler, number of IDs used by each patient, beliefs about inhaler medication and some demographic, clinical and functional patients' characteristics. We aim to assess how they are related to inhalation technique. Methods: A cross-sectional study was conducted in a hospital outpatient respiratory care. COPD patients over 40 years old, diagnosed according to GOLD criteria, and using IDs were included consecutively. The Beliefs about Medicines Questionnaire (BMQ), a demographic and a clinical survey were applied. The number of IDs used by each patient and the patients’ preference for some IDs were recorded. Patients were asked to demonstrate the use of their prescribed inhalation devices, and inhaler technique was assessed by using previously defined checklists, including essential steps and critical errors. A statistics analysis was then performed. Results: We studied 300 subjects performing a total of 521 inhalation manoeuvers with 10 different IDs. At least one step incorrectly performed was found in 48.2% of demonstrations and in 29.9% critical errors were observed. Misuse was related to priming/loading in 6.9%, to inhalation manoeuver in 13.1% and to both in 10%. There was a statistically significant association between critical errors and type of ID (P<0.001). No significant relationship was found between correct performance of key manoeuvers and patients’ preference or number of inhalers used per patient. Misuse due to critical errors was observed in 39.3% of patients and was positively related to female gender, age ≥65, lower education level and lower socioeconomic status (higher Graffar classification score), but not to patients’ clinical or functional characteristics. In the sub-group of patients presenting critical errors when using IDs, there was a statistically significant inverse association between BMQ Necessity score and number of critical errors. Conclusions: Inhalers mishandling remains disappointingly common. A good inhalation technique depends on the type of ID, and failure of inhalation manoeuver was the main cause of ID misuse. It was not associated to multiple inhalers’ use nor to patient’s preference, but to the patient’s beliefs about the necessity to use them. Elderly patients, women and those with lower education level or lower socioeconomic status demonstrate a worse inhalation technique.
Collapse
Affiliation(s)
- A Duarte-de-Araújo
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, Portugal.,ICVS/3B's, PT Government Associate Laboratory, Braga/Guimarães, Portugal.,Respiratory Department, H. Sª Oliveira, Guimarães, Portugal
| | - P Teixeira
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, Portugal.,ICVS/3B's, PT Government Associate Laboratory, Braga/Guimarães, Portugal
| | - V Hespanhol
- Department of Pneumology, Centro Hospitalar de S. João, Porto, Portugal.,Faculty of Medicine (FMUP), University of Porto, Porto, Portugal
| | - J Correia-de-Sousa
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Braga, Portugal.,ICVS/3B's, PT Government Associate Laboratory, Braga/Guimarães, Portugal.,Horizonte Family Health Unit, Matosinhos, Portugal
| |
Collapse
|
37
|
Balamurugan S, Apte K, Singh BP, Deb AK, Deshmukh C, Modi K, Godse A, Dhar R, Lahiri KR, Singh V, Pandya H, Rajan S, Vaidya A, Gaur V, Gogtay J. Device-handling study of a novel breath-actuated inhaler, Synchrobreathe®, versus a pMDI. Respir Med 2019; 161:105707. [PMID: 32056719 DOI: 10.1016/j.rmed.2019.05.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 05/06/2019] [Accepted: 05/22/2019] [Indexed: 12/16/2022]
Abstract
INTRODUCTION Synchrobreathe®, a new-generation, novel breath-actuated inhaler (BAI) can address the key issues arising during the use of both pressurised metered dose inhalers ([pMDIs]; hand-breath coordination) and dry powder inhalers ([DPIs]; high inspiratory flow required) with respect to optimal drug deposition. MATERIALS AND METHODS This was an open-label, prospective, 2-week, multicentre study that assessed device handling, ease of use, errors and participant perception regarding the use of Synchrobreathe® versus a pMDI in patients with chronic obstructive pulmonary disease (COPD) (n = 162) or asthma (n = 239) and inhaler-naïve healthy volunteers (n = 59). Ability to use the device without errors at the first attempt, total number of errors before and after training, time taken to use the device correctly and total number of training sessions, and number of attempts to perform the correct technique on Day 1 and Day 14 were evaluated. Device handling and preference questionnaires were also administered on Day 14. RESULTS Of 460 participants, 421 completed the study. The number of participants using Synchrobreathe without any error after reading the patient information leaflet (PIL) was significantly low (p < 0.05) on Day 1. On Day 14, significantly more number of participants used Synchrobreathe without any error (p < 0.001). The total number of errors before and after training with Synchrobreathe was significantly less (p < 0.001). The average time required to perform the inhalation technique correctly (p < 0.01) and the total number of attempts (P < 0.001) with Synchrobreathe were significantly lower. The average number of attempts to inhale correctly was significantly (p < 0.001) less with Synchrobreathe on Day1 and Day 14. Most participants rated Synchrobreathe as their choice of inhaler. CONCLUSION Synchrobreathe is an easy-to-use and easy-to-handle device with significantly less number of errors, which may have positive implications for disease control in asthma and COPD.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Keya Rani Lahiri
- Padmashree Dr. D. Y. Patil Medical College, Hospital & Research Centre, Navi Mumbai, India
| | | | - Hiren Pandya
- Ratandeep Multispecialty Hospital, Ahmedabad, India
| | | | | | - Vaibhav Gaur
- Medical Affairs Department, Cipla Ltd, Mumbai, India
| | | |
Collapse
|
38
|
Nobody Does it Better: A Patient Physician Perspective of Asthma Management. Pulm Ther 2019; 5:5-10. [PMID: 32026425 PMCID: PMC6966971 DOI: 10.1007/s41030-019-0088-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Indexed: 11/19/2022] Open
Abstract
This article, co-authored by a patient living with asthma and a consultant physician in respiratory medicine, describes the patient’s experience of asthma. The physician then discusses asthma management in the context of the patient’s experiences.
Collapse
|
39
|
Duarte AG, Tung L, Zhang W, Hsu ES, Kuo YF, Sharma G. Spirometry Measurement of Peak Inspiratory Flow Identifies Suboptimal Use of Dry Powder Inhalers in Ambulatory Patients with COPD. CHRONIC OBSTRUCTIVE PULMONARY DISEASES-JOURNAL OF THE COPD FOUNDATION 2019; 6:246-255. [PMID: 31189057 DOI: 10.15326/jcopdf.6.3.2018.0163] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Objectives Determine the prevalence of suboptimal peak inspiratory flow rate (PIFR) and associated patient characteristics and compare PIFR measurements obtained with spirometry and In-Check DIAL® device in ambulatory patients with COPD. Methods Patients underwent PIFR measurement with In-Check DIAL® device and pulmonary function testing with calibrated equipment. Group characteristics and lung function were compared for patients with suboptimal (≤ 60 L/min) and optimal (> 60 L/min) PIFR. Receiver operating curve analysis determined the best maximal forced inspiratory flow (FIF max) value in identifying optimal PIFR by gender and height. Results From July 1, 2016 to January 31, 2018, a total of 303 patients with chronic obstructive pulmonary disease (COPD) had PIFR and pulmonary function measurements. Group mean age was 65.5 ± 11.3 years with equal gender distribution. Suboptimal PIFR was observed in 61 (20.1%) patients. A significant correlation was observed between PIFR and FIF max, inspiratory capacity and residual volume (RV) to total lung capacity (TLC) ratio. In the suboptimal PIFR group, mean FIF max measured by spirometry was significantly less compared with the optimal PIFR group; 178.5 ± 56.9 L/min and 263.4 ± 89.9 L/min, respectively (p<0.0001). Receiver operator curve analysis of FIF max to identify an optimal PIFR yielded an area under the curve of 0.79. Males < 65 inches had a suboptimal PIFR in 16.7 % of the male cohort, while females < 65 inches had a suboptimal PIFR in 27.4 % of the women. Conclusions Suboptimal PIFR was present in 1 in 5 stable patients with COPD and was more frequent in short statured females. Spirometry determined FIF max was associated with PIFR based on gender and height.
Collapse
Affiliation(s)
- Alexander G Duarte
- Division of Pulmonary, Critical Care and Sleep Medicine, Department of Internal Medicine, University of Texas Medical Branch, Galveston
| | - Leon Tung
- Division of Pulmonary, Critical Care and Sleep Medicine, Department of Internal Medicine, University of Texas Medical Branch, Galveston
| | - Wei Zhang
- Division of Pulmonary, Critical Care and Sleep Medicine, Department of Internal Medicine, University of Texas Medical Branch, Galveston
| | - En Shuo Hsu
- Office of Biostatistics, University of Texas Medical Branch, Galveston
| | - Yong-Fang Kuo
- Office of Biostatistics, University of Texas Medical Branch, Galveston.,Sealy Center of Aging, University of Texas Medical Branch, Galveston
| | - Gulshan Sharma
- Division of Pulmonary, Critical Care and Sleep Medicine, Department of Internal Medicine, University of Texas Medical Branch, Galveston.,Sealy Center of Aging, University of Texas Medical Branch, Galveston
| |
Collapse
|
40
|
Errors in Aerosol Inhaler Use and Their Effects on Maternal and Fetal Outcomes among Pregnant Asthmatic Women (Subanalysis from QAKCOP Study). Can Respir J 2018; 2018:7649629. [PMID: 30662579 PMCID: PMC6312601 DOI: 10.1155/2018/7649629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 09/17/2018] [Accepted: 11/01/2018] [Indexed: 11/17/2022] Open
Abstract
Data on inhaler technique and its effects on maternal and fetal outcomes during pregnancy are seldom reported. The primary objective of this study was to evaluate inhaler technique and identify errors in inhaler use among pregnant women with asthma. Secondary objectives were to identify factors associated with poor inhaler technique and study the association between inhaler technique and maternal and fetal outcomes. This was a cross-sectional, face-to-face, prospective study of 80 pregnant women with physician-diagnosed asthma. Seventy-three and 41 asthmatic pregnant women reported using pressurized metered dose inhalers (pMDIs) and dry powder inhalers (DPIs), respectively. Overall, wrong inhaler technique was observed in 47 (64.4%) subjects. Among pMDI users, correct inhaler use was observed in only 26/73 (35.6%) of the patients, with lack of coordination between inhalation and generation of the aerosol and failure to breathe out gently before using the inhaler, being the most common errors. Among DPI users, 21 (51.2%) demonstrated correct inhaler use, with failure to perform a breath-hold for 10 seconds after inhaling the powder and to exhale gently before using the inhaler being the most common errors. Significant associations between inhaler technique and patient's understanding of asthma medications and the kind of follow-up clinic (respiratory versus nonrespiratory clinic) were found. No significant associations between inhaler technique and various maternal and fetal outcomes or asthma control were found. In conclusion, improper inhalation technique is significantly prevalent in pregnant asthmatic women, particularly among those being followed in nonspecialized respiratory clinics. The lack of significant association between the inhaler technique and asthma control (and hence maternal and fetal outcomes) may simply reflect the high prevalence of uncontrolled asthma and significant contribution of other barriers to poor asthma control in the current patient's cohort. Multidisciplinary management of asthma during pregnancy with particular emphasis on patient's education is imperative.
Collapse
|
41
|
Wang H, Sebrié C, Judé S, Maurin A, Rétif S, Le Mée M, Julea F, Dubuisson RM, Willoquet G, Bouazizi K, Darrasse L, Guillot G, Maître X, de Rochefort L. Quantitative Gd-DOTA-based aerosol deposition mapping in the lungs of asthmatic rats using 3D UTE-MRI. NMR IN BIOMEDICINE 2018; 31:e4013. [PMID: 30307075 DOI: 10.1002/nbm.4013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 08/09/2018] [Accepted: 08/13/2018] [Indexed: 06/08/2023]
Abstract
Asthma is a chronic respiratory disease, commonly treated with inhaled therapy. Better understanding of the mechanisms of aerosol deposition is required to improve inhaled drug delivery. Three-dimensional ultrashort echo time (UTE) MRI acquisitions at 1.5 T were combined with spontaneous nose-only inhalation of aerosolized gadolinium (Gd) to map the aerosol deposition and to characterize signal enhancement in asthmatic rat lungs. The rats were sensitized to ovalbumin (OVA) to develop asthmatic models and challenged before imaging by nebulization of OVA to trigger asthmatic symptoms. The negative controls were not sensitized or challenged by nebulization of saline. The animal lungs were imaged before and after administration of Gd-based aerosol in freely breathing rats, by using a T1 -weighted 3D UTE sequence. A contrast-enhanced quantitative analysis was performed to assess regional concentration. OVA-sensitized rats had lower signal enhancement and lower deposited aerosol concentration. Their enhancement dynamics showed large inter-subject variability. The signal intensity was homogeneously enhanced for controls while OVA-sensitized rats showed heterogeneous enhancement. Contrast-enhanced 3D UTE was applied with aerosolized Gd to efficiently measure spatially resolved deposition in asthmatic lungs. The small administered dose (around 1 μmol/kg body weight) and the use of standard clinical MRI suggest a potential application for the exploration of asthma.
Collapse
Affiliation(s)
- Hongchen Wang
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Catherine Sebrié
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | | | - Anne Maurin
- Centre de Recherches Biologiques CERB, Baugy, France
| | - Stéphanie Rétif
- Centre d'Imagerie du Petit Animal CIPA, PHENOMIN-TAAM UPS44, CNRS Orléans, France
| | - Marilyne Le Mée
- Centre d'Imagerie du Petit Animal CIPA, PHENOMIN-TAAM UPS44, CNRS Orléans, France
| | - Felicia Julea
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Rose-Marie Dubuisson
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Georges Willoquet
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Khaoula Bouazizi
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Luc Darrasse
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Geneviève Guillot
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Xavier Maître
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
| | - Ludovic de Rochefort
- Imagerie par Résonance Magnétique Médicale et Multi-Modalités (UMR8081) IR4M, CNRS, Université Paris-Sud, Université Paris-Saclay, Orsay, France
- Center for Magnetic Resonance in Biology and Medicine (UMR 7339), CRMBM, CNRS-Aix Marseille Université, Marseille, France
| |
Collapse
|
42
|
Windisch W, Schwarz SB, Magnet FS, Dreher M, Schmoor C, Storre JH, Knipel V. Using web-based videos to improve inhalation technique in COPD patients requiring hospitalization: A randomized controlled trial. PLoS One 2018; 13:e0201188. [PMID: 30325931 PMCID: PMC6191087 DOI: 10.1371/journal.pone.0201188] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 07/06/2018] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Inhalation errors frequently occur in patients receiving inhalation treatment, which can significantly impair treatment success. While this underscores the importance of inhalation training, the role of modern web-based instructional videos has not yet been investigated. METHODS A randomized controlled trial using standardized checklists (10 items: preparation, N = 3, inhalation routine, N = 6, and closure of inhalation, N = 1) was carried out to determine the relative effects of web-based, device-specific videos versus standard personal instruction on reducing multiple (≥2) inhalation errors in severe COPD patients requiring hospitalisation. Investigators assessing inhalation errors were blinded to the intervention. RESULTS Multiple handling errors were recorded at baseline in 152 out of 159 patients (95.6%). Each teaching method led to a similar reduction in errors (videos: from 4.2±1.6 to 1.5±1.5 errors; personal instruction: from 3.8±1.5 to 1.3±1.6; p<0.0001), although non-inferiority of web-based video teaching could not be confirmed statistically due to an unpredictably high number of patients in both groups still making multiple handling errors (44.0% versus 40.3%, mean difference 3.7%; 95%CI [-12.0-19.4%]). CONCLUSION Multiple inhalation errors regularly occur in severe COPD patients requiring hospitalisation. Web-based video teaching is capable of reducing inhalation errors. However, compared to personal instruction non-inferiority could not be established. This was due to an unexpectedly high number of patients with persisting inhalation errors despite training. TRIAL REGISTRATION Clinical trial Registration: German Clinical Trial Register, DRKS 00004320.
Collapse
Affiliation(s)
- Wolfram Windisch
- Department of Pneumology, Kliniken der Stadt Köln gGmbH, Universität Witten/Herdecke, Cologne, Germany
| | - Sarah Bettina Schwarz
- Department of Pneumology, Kliniken der Stadt Köln gGmbH, Universität Witten/Herdecke, Cologne, Germany
| | - Friederike Sophie Magnet
- Department of Pneumology, Kliniken der Stadt Köln gGmbH, Universität Witten/Herdecke, Cologne, Germany
| | - Michael Dreher
- Department of Pneumology, University Hospital RWTH Aachen, Aachen, Germany
| | - Claudia Schmoor
- Clinical Trials Department, Faculty of Medicine and Medical Center—University of Freiburg, Freiburg, Germany
| | - Jan Hendrik Storre
- Department of Intensive Care, Sleep Medicine and Mechanical Ventilation, Asklepios Fachkliniken Munich-Gauting, Munich-Gauting, Germany
- Department of Pneumology, University Medical Hospital, Freiburg, Germany
| | - Verena Knipel
- Department of Pneumology, Kliniken der Stadt Köln gGmbH, Universität Witten/Herdecke, Cologne, Germany
| |
Collapse
|
43
|
Adib-Hajbaghery M, Karimi Z. Comparing the Effects of Face-to-face and Video-based Education on Inhaler Use: A Randomized, Two-group Pretest/posttest Study. IRANIAN JOURNAL OF NURSING AND MIDWIFERY RESEARCH 2018; 23:352-357. [PMID: 30186339 PMCID: PMC6111659 DOI: 10.4103/ijnmr.ijnmr_17_18] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Background: The quality of inhaler use can significantly affect the effectiveness of inhalation medications. This study was done to compare the effects of face-to-face and video-based education methods on inhaler use. Materials and Methods: A quasi-experimental, pretest/posttest clinical trial study was conducted on 120 patients with respiratory diseases who were under treatment with metered-dose inhalers. Patients were randomly allocated into two groups to receive either face-to-face (n = 60) or video-based education (n = 60) about correct inhaler use. Inhaler use was assessed using a 15-item checklist before, 2 weeks, and 1 month after the education. Chi-square and independent sample t-test as well as repeated-measures analysis of variance were used for data analysis. Results: At baseline, the groups did not differ significantly in inhaler use as shown by the mean score (t = 0.81, p = 0.33). Repeated-measures analysis showed that the mean score of inhaler use significantly increased in both groups 2 weeks and 1 month after the intervention (F = 585.07, p < 0.001). The t-test showed that at 2 weeks and 1 month after intervention the amount of increase in the face-to-face group was significantly greater than the video-based group (t = 3.31 and 5.93, p < 0.001). Conclusions: Both face-to-face and video-based education methods significantly improve inhaler use, even though the effects of the face-to-face method are significantly greater. Nurses can use either of these two methods or both for education of patients about inhaler use.
Collapse
Affiliation(s)
- Mohsen Adib-Hajbaghery
- Trauma Nursing Research Centre, Faculty of Nursing and Midwifery, Kashan University of Medical Sciences, Kashan, Iran
| | - Zeynab Karimi
- Trauma Nursing Research Centre, Faculty of Nursing and Midwifery, Kashan University of Medical Sciences, Kashan, Iran
| |
Collapse
|
44
|
Scullion J. The Nurse Practitioners' Perspective on Inhaler Education in Asthma and Chronic Obstructive Pulmonary Disease. Can Respir J 2018; 2018:2525319. [PMID: 30154941 PMCID: PMC6098863 DOI: 10.1155/2018/2525319] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Accepted: 07/09/2018] [Indexed: 12/13/2022] Open
Abstract
Asthma and chronic obstructive pulmonary disease (COPD) can be debilitating conditions adversely affecting a person's quality of life. Effective treatments are available, but common errors in the use of inhalers compound the issue of disease control. The beliefs and concerns of a patient can also have an impact on treatment adherence, the consequences of which are diminished disease control and the occurrence of exacerbations. Once a treatment has been prescribed, it is often nurses who manage the patient long-term, and they may even be the main care provider. This puts nurses in a key position to monitor inhaler technique, communicate with the patient to improve adherence, and even suggest alternative treatments if the patient and therapy are incompatible. This review examines the central role that nurses play in disease management and emphasizes how effective inhaler education can make a difference to disease control. Good communication between the nurse and patient is vital if this is to be achieved. Recent updates to asthma and COPD guidelines are reviewed, and key resources available to help manage patients are highlighted. Finally, with regard to inhaler education, we reconsider the nursing keystones of "Know it," "Show it," "Teach it," and "Review it."
Collapse
Affiliation(s)
- Jane Scullion
- University Hospitals of Leicester NHS Trust, Leicester, UK
| |
Collapse
|
45
|
Locke ER, Thomas RM, Woo DM, Nguyen EHK, Tamanaha BK, Press VG, Reiber GE, Kaboli PJ, Fan VS. Using Video Telehealth to Facilitate Inhaler Training in Rural Patients with Obstructive Lung Disease. Telemed J E Health 2018; 25:230-236. [PMID: 30016216 DOI: 10.1089/tmj.2017.0330] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Proper inhaler technique is important for effective drug delivery and symptom control in chronic obstructive pulmonary disease (COPD) and asthma, yet not all patients receive inhaler instructions. INTRODUCTION Using a retrospective chart review of participants in a video telehealth inhaler training program, the study compared inhaler technique within and between monthly telehealth visits and reports associated with patient satisfaction. MATERIALS AND METHODS Seventy-four (N = 74) rural patients prescribed ≥1 inhaler participated in three to four pharmacist telehealth inhaler training sessions using teach-to-goal (TTG) methodology. Within and between visit inhaler technique scores are compared, with descriptive statistics of pre- and postprogram survey results including program satisfaction and computer technical issues. Healthcare utilization is compared between pre- and post-training periods. RESULTS Sixty-nine (93%) patients completed all three to four video telehealth inhaler training sessions. During the initial visit, patients demonstrated improvement in inhaler technique for metered dose inhalers (albuterol, budesonide/formoterol), dry powder inhalers (formoterol, mometasone, tiotropium), and soft mist inhalers (ipratropium/albuterol) (p < 0.01 for all). Improved inhaler technique was sustained at 2 months (p < 0.01). Ninety-four percent of participants were satisfied with the program. Although technical issues were common, occurring among 63% of attempted visits, most of these visits (87%) could be completed. There was no significant difference in emergency department visits and hospitalizations pre- and post-training. DISCUSSION This study demonstrated high patient acceptance of video telehealth training and objective improvement in inhaler technique. CONCLUSIONS Video telehealth inhaler training using the TTG methodology is a promising program that improved inhaler technique and access to inhaler teaching for rural patients with COPD or asthma.
Collapse
Affiliation(s)
- Emily R Locke
- 1 Health Services Research and Development (HSR&D), Seattle Center of Innovation for Veteran-Centered and Value-Driven Care, VA Puget Sound Health Care System, Seattle, Washington
| | - Rachel M Thomas
- 1 Health Services Research and Development (HSR&D), Seattle Center of Innovation for Veteran-Centered and Value-Driven Care, VA Puget Sound Health Care System, Seattle, Washington
| | - Deborah M Woo
- 2 Pharmacy and Nutritional Care, VA Puget Sound Health Care System, Seattle, Washington
| | - Ethan H K Nguyen
- 2 Pharmacy and Nutritional Care, VA Puget Sound Health Care System, Seattle, Washington
| | - Bryson K Tamanaha
- 2 Pharmacy and Nutritional Care, VA Puget Sound Health Care System, Seattle, Washington
| | - Valerie G Press
- 3 Department of Medicine, University of Chicago, Chicago, Illinois
| | - Gayle E Reiber
- 1 Health Services Research and Development (HSR&D), Seattle Center of Innovation for Veteran-Centered and Value-Driven Care, VA Puget Sound Health Care System, Seattle, Washington
| | - Peter J Kaboli
- 4 The Comprehensive Access and Delivery Research and Evaluation (CADRE) Center, Iowa City VA Health Care System, Iowa City, Iowa.,5 Department of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, Iowa
| | - Vincent S Fan
- 1 Health Services Research and Development (HSR&D), Seattle Center of Innovation for Veteran-Centered and Value-Driven Care, VA Puget Sound Health Care System, Seattle, Washington.,6 Department of Medicine, University of Washington, Seattle, Washington
| |
Collapse
|
46
|
Luczak-Wozniak K, Dabrowska M, Domagala I, Miszczuk M, Lubanski W, Leszczynski A, Krenke R. Mishandling of pMDI and DPI inhalers in asthma and COPD - Repetitive and non-repetitive errors. Pulm Pharmacol Ther 2018; 51:65-72. [PMID: 29964174 DOI: 10.1016/j.pupt.2018.06.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 06/23/2018] [Accepted: 06/28/2018] [Indexed: 11/27/2022]
Abstract
BACKGROUND Pharmacological treatment of asthma and chronic obstructive pulmonary disease (COPD) is based mainly on inhaled medications. There is a continuous need to examine and train patients in their inhalation technique. The objective of the presented study is to determine whether the errors which patients made during inhalations are repetitive, and therefore easier to eradicate, or rather accidental, hence require more attention and effort from the health care professionals. METHODS It was a prospective, cohort study which included adults with asthma or COPD, who have used at least one inhaler daily on a regular basis. Inhalation technique was evaluated twice in a six months interval basing on a list of the most common errors in the inhalation technique. There was no training of inhalation skills between visits. RESULTS There were 92 patients (46 asthmatics, 46 with COPD; median age 66 years, median duration of the disease 10 years) included into the analysis. 92% of patients made at least one error during their inhalation. Among pMDI users the most common device mishandlings were: no or too short breath-holding after inhalation (60% of the patients during the first visit; 50% during the 2nd), too rapid and too forceful inhalation (52%; 61%) and lack of exhalation before the use of the medicine (48%; 43%). Among the DPI users, the most numerous errors were: no or too short (less than 3 s) breath-holding after inhalation (62%; 55%) and slow and not forceful enough inhalation (38%; 36%). When comparing the mishandlings in the inhalation technique conducted during the first and second visit the majority of the errors conducted by the patients were repetitive. However, some errors such as too early termination of inhalation (p = 0.016), inhalation through the nose during actuation (p = 0.002) among pMDI users and lack of expiration before inhalation (p = 0.027) among DPI users, were non-permanent. CONCLUSIONS Improper inhalation technique is very common and the majority of errors made in inhalation technique are repetitive. This emphasizes the role of an ongoing verification and training of a proper inhalation technique in all patients that are regularly treated with inhalers.
Collapse
Affiliation(s)
| | - Marta Dabrowska
- Department of Internal Medicine, Pulmonary Diseases and Allergy, Medical University of Warsaw, Poland.
| | - Izabela Domagala
- Students' Research Group "Alveolus", Medical University of Warsaw, Poland
| | - Marta Miszczuk
- Students' Research Group "Alveolus", Medical University of Warsaw, Poland
| | - Wojciech Lubanski
- Students' Research Group "Alveolus", Medical University of Warsaw, Poland
| | | | - Rafal Krenke
- Department of Internal Medicine, Pulmonary Diseases and Allergy, Medical University of Warsaw, Poland
| |
Collapse
|
47
|
Chronic obstructive pulmonary disease in the long-term care setting: current practices, challenges, and unmet needs. Curr Opin Pulm Med 2018; 23 Suppl 1:S1-S28. [PMID: 28990958 DOI: 10.1097/mcp.0000000000000416] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
: Chronic obstructive pulmonary disease (COPD) is a prevalent and disabling disorder in the United States, especially affecting older individuals, women, and those with a history of smoking. Studies show that COPD may be underrepresented, underdiagnosed, and undertreated in elderly patients residing in long-term care (LTC) facilities. The quality of care for LTC residents with COPD is heterogeneous in regard to both the facility and the patient. For LTC facilities, care should be driven by staff education, interstaff communication, and interfacility communication. From the perspective of the LTC patient, choice of medication and device should be based on appropriate diagnosis, comorbidities, ability to perform treatment, and patient preferences. Nebulization is currently underutilized in LTC settings, although it would benefit older patients with low peak inspiratory flow, cognitive impairment, and/or physical impairment, which may preclude them from using other inhalation devices. Authors developed a COPD treatment algorithm that focuses on three primary patient aspects to consider when deciding on respiratory device in patients in LTC facilities: inspiratory flow, hand dexterity and coordination, and cognitive capacity.
Collapse
|
48
|
Mehri R, Tang W, Matida EA, Lai EPC. Aerosolization of Zn-DTPA Decorporation Agent Using Jet and Ultrasonic Nebulizers. J Aerosol Med Pulm Drug Deliv 2018; 31:311-320. [PMID: 29641361 DOI: 10.1089/jamp.2017.1419] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Chelating agents such as diethylenetriamine pentaacetic acid (DTPA) can be used as a decorporation drug in the zinc (Zn) form to treat internal radioactive contamination after exposure to plutonium or americium in a nuclear accident. Although Zn-DTPA is normally administered intravenously, inhalation of Zn-DTPA in aerosol form is a better route for direct delivery to the lungs. This work investigates the feasibility of synthesizing Zn-DTPA from three common chemicals and aerosolizing it using a jet or ultrasonic nebulizer. METHODS The particle size distribution (PSD) of this decorporation agent at different concentrations were tested in vitro using two different methods: inertial impaction and aerodynamic time of flight. The particles were generated using either a jet nebulizer or an ultrasonic nebulizer. Two parameters, namely the mass median aerodynamic diameter and the geometric standard deviation, were assessed to determine the PSD of the generated aerosols. These parameters were obtained for different concentrations of Zn-DTPA using both nebulizers. RESULTS AND CONCLUSIONS Zn-DTPA was successfully synthesized for decorporation purposes. Aerosol particles within the inhalable range were successfully generated by both nebulizers from four different concentrations of Zn-DTPA. It was found that the medication concentration did not affect the PSD of Zn-DTPA. The ultrasonic nebulizer was observed to produce a slightly larger aerosol particle size and required slightly longer treatment periods to deliver an effective dose to the lungs when compared with the jet nebulizer. Both nebulizers can be sustainably run to administer the agent for effective decorporation treatment of a large population after any major nuclear accident.
Collapse
Affiliation(s)
- Rym Mehri
- 1 Department of Mechanical and Aerospace Engineering, Carleton University , Ottawa, Ontario, Canada
| | - Weiquan Tang
- 2 Department of Chemistry, Carleton University , Ottawa, Ontario, Canada
| | - Edgar A Matida
- 1 Department of Mechanical and Aerospace Engineering, Carleton University , Ottawa, Ontario, Canada
| | - Edward P C Lai
- 2 Department of Chemistry, Carleton University , Ottawa, Ontario, Canada
| |
Collapse
|
49
|
McIvor RA, Devlin HM, Kaplan A. Optimizing the Delivery of Inhaled Medication for Respiratory Patients: The Role of Valved Holding Chambers. Can Respir J 2018; 2018:5076259. [PMID: 29849831 PMCID: PMC5904796 DOI: 10.1155/2018/5076259] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2017] [Revised: 01/26/2018] [Accepted: 02/12/2018] [Indexed: 02/02/2023] Open
Abstract
Valved holding chambers (VHCs) have been used with pressurized metered-dose inhalers since the early 1980s. They have been shown to increase fine particle delivery to the lungs, decrease oropharyngeal deposition, and reduce side effects such as throat irritation, dysphonia, and oral candidiasis that are common with use of pressurized metered-dose inhalers (pMDIs) alone. VHCs act as aerosol reservoirs, allowing the user to actuate the pMDI device and then inhale the medication in a two-step process that helps users overcome challenges in coordinating pMDI actuation with inhalation. The design of VHC devices can have an impact on performance. Features such as antistatic properties, effective face-to-facemask seal feedback whistles indicating correct inhalation speed, and inhalation indicators all help improve function and performance, and have been demonstrated to improve asthma control, reduce the rate of exacerbations, and improve quality of life. Not all VHCs are the same, and they are not interchangeable. Each pairing of a pMDI device plus VHC should be considered as a unique delivery system.
Collapse
Affiliation(s)
- R. Andrew McIvor
- St. Joseph's Healthcare Hamilton, McMaster University, Hamilton, ON, Canada
| | | | - Alan Kaplan
- Family Physician Airways Group of Canada, Richmond Hill, ON, Canada
- Department of Family and Community Medicine, University of Toronto, Toronto, ON, Canada
- Health Quality Ontario COPD Community Standards Project, Toronto, ON, Canada
| |
Collapse
|
50
|
Bosnic-Anticevich SZ. Continued Innovation in Respiratory Care: The Importance of Inhaler Devices. Tuberc Respir Dis (Seoul) 2018; 81:91-98. [PMID: 29589381 PMCID: PMC5874147 DOI: 10.4046/trd.2017.0119] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Revised: 11/03/2017] [Accepted: 11/06/2017] [Indexed: 11/30/2022] Open
Abstract
When it comes to the use in inhalers in the management of chronic obstructive pulmonary diseases, there are many options, considerations and challenges, which health care professionals need to address. Considerations for prescribing and dispensing, administering and following up, education, and adherence; all of these factors impact on treatment success and all are intrinsically linked to the device selected. This review brings together relevant evidence, real-life data and practice tools to assist health care professionals in making decisions about the use of inhalers in the management of chronic obstructive pulmonary diseases. It covers some of the key technical device issues to be considered, the evidence behind the role of inhalers in disease control, population studies which link behaviors and adherence to inhaler devices as well as practice advice on inhaler technique education and the advantages and disadvantages in selecting different inhaler devices. Finally, a list of key considerations to aid health care providers in successfully managing the use of inhaler devices are summarized.
Collapse
|