Chancharoen P, Tangpornprasert P, Amarase C, Tantavisut S, Virulsri C. Design of osteosynthesis plate for detecting bone union using wire natural frequency. Sci Rep 2024; 14:12569. [PMID: 38822126 PMCID: PMC11143194 DOI: 10.1038/s41598-024-63530-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 05/29/2024] [Indexed: 06/02/2024] Open
Abstract
We have developed a novel osteosynthesis plate with bone union detection using a wire's natural frequency (BUDWF) to provide the quantitative result of bone union detection. The concept for detecting bone union is measuring the rate of frequency change. The frequency is measured from sound generated from the wire attached to a modified plate. The plate is modified from a Syncera ADLER B0409.10 and attached with 0.3 mm diameter 316L stainless steel wire. The sound generation mechanism was created by PEEK and installed on the plate to generate the sound. The preliminary experiments were conducted on a Sawbones tibia composite mimic. We used the cut Sawbones to create fracture samples with a 0, 0.5, 1-, 2-, and 5-mm gap representing the fractured bone with different gap sizes and prepared uncut Sawbones as a union sample. These samples were tested five times, and the sound was recorded from a condenser microphone and analyzed. We found that the BUDWF can differentiate samples with a fracture gap above 2 mm from the union sample, as the differences in the rates of frequency change between samples with a fracture gap above 2 mm and union samples were statistically significant. However, there was a limitation that the BUDWF plate was still unable to differentiate the 0 mm fracture gap and the union sample in this study.
Collapse
Affiliation(s)
- Pisitpong Chancharoen
- Center of Excellence for Prosthetic and Orthopedic Implant, Chulalongkorn University, Bangkok, 10330, Thailand
- Biomedical Engineering Research Center, Faculty of Engineering, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Pairat Tangpornprasert
- Center of Excellence for Prosthetic and Orthopedic Implant, Chulalongkorn University, Bangkok, 10330, Thailand.
- Biomedical Engineering Research Center, Faculty of Engineering, Chulalongkorn University, Bangkok, 10330, Thailand.
- Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, 10330, Thailand.
| | - Chavarin Amarase
- Hip Fracture Research Unit, Department of Orthopedic, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Saran Tantavisut
- Hip Fracture Research Unit, Department of Orthopedic, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Chanyaphan Virulsri
- Center of Excellence for Prosthetic and Orthopedic Implant, Chulalongkorn University, Bangkok, 10330, Thailand
- Biomedical Engineering Research Center, Faculty of Engineering, Chulalongkorn University, Bangkok, 10330, Thailand
- Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, 10330, Thailand
| |
Collapse
|
2
|
Le Stum M, Clave A, Adzinyo Agbemanyole K, Stindel E, Le Goff-Pronost M. A pilot study on preferences from surgeons to deal with an innovative customized and connected knee prosthesis - A discret choice experiment. Heliyon 2024; 10:e30041. [PMID: 38784553 PMCID: PMC11112283 DOI: 10.1016/j.heliyon.2024.e30041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 05/25/2024] Open
Abstract
Background To address the increasing global demand for Total Knee Arthroplasty and reduce the need for revisions, several technologies combining 3D planning and artificial intelligence have emerged. These innovations aim to enhance customization, improve component positioning accuracy and precision. The integration of these advancements paves the way for the development of personalized and connected knee implant. Questions/purposes These groundbreaking advancements may necessitate changes in surgical practices. Hence, it is important to comprehend surgeons' intentions in integrating these technologies into their routine procedures. Our study aims to assess how surgeons' preferences will affect the acceptability of using this new implant and associated technologies within the entire care chain. Methods We employed a Discrete Choice Experiment, a predictive technique mirroring real-world healthcare decisions, to assess surgeons' trade-off evaluations and preferences. Results A total of 90 experienced surgeons, performing a significant number of procedures annually (mostly over 51) answered. Analysis indicates an affinity for technology but limited interest in integrating digital advancements like preoperative software and robotics. However, they are receptive to practice improvements and considering the adoption of future sensors. Conclusions In conclusion, surgeons prefer customized prostheses via augmented reality, accepting extra cost. Embedded sensor technology is deemed premature by them.
Collapse
Affiliation(s)
- Mathieu Le Stum
- Université de Brest, UBO, LATIM, UMR 1101, 22 rue Camille Desmoulins, 29200, Brest, France
- Institut National de la Santé et de la Recherche Médicale, Inserm, LaTIM, UMR 1101, 22 rue Camille Desmoulins, 29200, Brest, France
| | - Arnaud Clave
- Service d'orthopédie, Clinique Saint George, 2 Avenue de Rimiez, 06100, Nice, France
| | - Koffi Adzinyo Agbemanyole
- Institut Mines-Telecom, IMT Atlantique, LATIM, UMR 1101, M@rsouin, 655 Av. du Technopôle, 29280, Plouzané, France
| | - Eric Stindel
- Université de Brest, UBO, LATIM, UMR 1101, 22 rue Camille Desmoulins, 29200, Brest, France
- Centre Hospitalo-Universitaire de Brest, CHU Brest, LATIM, UMR 1101, 2 Avenue Foch, 29200, Brest, France
| | - Myriam Le Goff-Pronost
- Institut Mines-Telecom, IMT Atlantique, LATIM, UMR 1101, M@rsouin, 655 Av. du Technopôle, 29280, Plouzané, France
| |
Collapse
|
3
|
Patel V, Deshpande SV, Goel S, Suneja A, Jadawala VH. Intramedullary Kirschner Wire Fixation for Metatarsal Fractures: A Comprehensive Review of Treatment Outcomes. Cureus 2024; 16:e59368. [PMID: 38817526 PMCID: PMC11137647 DOI: 10.7759/cureus.59368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 04/30/2024] [Indexed: 06/01/2024] Open
Abstract
Metatarsal fractures pose significant challenges in orthopedic practice, necessitating effective treatment methods to ensure optimal patient outcomes. This comprehensive review focuses on intramedullary Kirschner wire fixation as a promising intervention for metatarsal fractures. Beginning with an overview of metatarsal fractures and the imperative for effective treatments, the review delves into intramedullary fixation's definition, historical background, advantages, and disadvantages. Indications for its use in metatarsal fractures are discussed, providing a foundation for understanding its application. The surgical technique section outlines critical aspects, including patient selection criteria and preoperative planning. Before presenting a detailed step-by-step procedure for intramedullary Kirschner wire fixation, anesthesia considerations are explored. Emphasizing precision, fluoroscopic guidance, and meticulous postoperative care, this section provides insights for surgeons and healthcare practitioners. Considerations for rehabilitation follow, addressing postoperative care, expected recovery timelines, and physical therapy recommendations. Early mobilization, weight-bearing guidelines, and a structured rehabilitation program play pivotal roles in recovery. In the conclusion, key findings are summarized, highlighting the efficacy of intramedullary Kirschner wire fixation, its advantages, and recommendations for clinical practice. Additionally, areas for future research are identified, guiding further exploration and refinement of this surgical approach. This review is valuable for clinicians, researchers, and healthcare practitioners involved in metatarsal fracture management, contributing to the evolution of treatment strategies and improving patient care.
Collapse
Affiliation(s)
- Vatsal Patel
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Sanjay V Deshpande
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Sachin Goel
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Anmol Suneja
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Vivek H Jadawala
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
4
|
Murphy RKJ. Smart Spine Implants. Neurosurg Clin N Am 2024; 35:229-234. [PMID: 38423738 DOI: 10.1016/j.nec.2023.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Smart spine implants promise to stimulate healing and provide objective information about healing progression. The ability of implants to accelerate healing and provide objective data could help guide postoperative care, foster better outcomes, and reduce complications. Real-time monitoring, remote control and programming, and data analytics are actively being developed and translated into clinical practice. This article discusses advances in smart spinal implant technology and how they may aid patients and surgeons.
Collapse
Affiliation(s)
- Rory K J Murphy
- Department of Neurosurgery, Barrow Neurological Institute, Neuroscience Publications, St. Joseph's Hospital and Medical Center, 350 West Thomas Road, Phoenix, AZ 85013, USA.
| |
Collapse
|
5
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
6
|
Crisco JJ, Henke JA, McDermott DG, Badida R, Morton AM, Kalshoven JM, Moore DC. Development of an implantable trapezium carpal bone replacement for measuring in vivo loads at the base of the thumb. J Biomech 2024; 165:112013. [PMID: 38401330 PMCID: PMC10956735 DOI: 10.1016/j.jbiomech.2024.112013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 01/22/2024] [Accepted: 02/19/2024] [Indexed: 02/26/2024]
Abstract
Understanding the loads that occur across musculoskeletal joints is critical to advancing our understanding of joint function and pathology, implant design and testing, as well as model verification. Substantial work in these areas has occurred in the hip and knee but has not yet been undertaken in smaller joints, such as those in the wrist. The thumb carpometacarpal (CMC) joint is a uniquely human articulation that is also a common site of osteoarthritis with unknown etiology. We present two potential designs for an instrumented trapezium implant and compare approaches to load calibration. Two instrumented trapezia designs were prototyped using strain gauge technology: Tube and Diaphragm. The Tube design is a well-established structure for sensing loads while the Diaphragm is novel. Each design was affixed to a 6-DOF load cell that was used as the reference. Loads were applied manually, and two calibration methods, supervised neural network (DEEP) and matrix algebra (MAT), were implemented. Bland-Altman 95% confidence interval for the limits of agreement (95% CI LOA) was used to assess accuracy. Overall, the DEEP calibration decreased 95% CI LOA compared with the MAT approach for both designs. The Diaphragm design outperformed the Tube design in measuring the primary load vector (joint compression). Importantly, the Diaphragm design permits the hermetic encapsulation of all electronics, which is not possible with the Tube design, given the small size of the trapezium. Substantial work remains before this device can be approved for implantation, but this work lays the foundation for further device development that will be required.
Collapse
Affiliation(s)
- Joseph J Crisco
- Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States.
| | - Julia A Henke
- Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States
| | - Daniel G McDermott
- Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States
| | - Rohit Badida
- Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States
| | - Amy M Morton
- Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States
| | - Josephine M Kalshoven
- Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States
| | - Douglas C Moore
- Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, United States
| |
Collapse
|
7
|
Sniderman J, Monarrez R, Drew J, Abdeen A. Mobile Application Use and Patient Engagement in Total Hip and Knee Arthroplasty. JBJS Rev 2024; 12:01874474-202402000-00003. [PMID: 38394327 DOI: 10.2106/jbjs.rvw.23.00208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2024]
Abstract
» Mobile applications (MAs) are widely available for use during the perioperative period and are associated with increased adherence to rehabilitation plans, increased satisfaction with care, and considerable cost savings when used appropriately.» MAs offer surgeons and health care stakeholders the ability to collect clinical data and quality metrics that are important to value-based reimbursement models and clinical research.» Patients are willing to use wearable technology to assist with data collection as part of MAs but prefer it to be comfortable, easy to apply, and discreet.» Smart implants have been developed as the next step in MA use and data collection, but concerns exist pertaining to patient privacy and cost.» The ongoing challenge of MA standardization, validation, equity, and cost has persisted as concerns regarding widespread use.
Collapse
Affiliation(s)
- Jhase Sniderman
- Department of Orthopaedic Surgery, Boston Medical Center, Boston University Medical School, Boston, Massachusetts
- Section of Orthopaedic Surgery, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Ruben Monarrez
- Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Replacement, Sinai Hospital, Baltimore, Maryland
| | - Jacob Drew
- Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Ayesha Abdeen
- Department of Orthopaedic Surgery, Boston Medical Center, Boston University Medical School, Boston, Massachusetts
| |
Collapse
|
8
|
Youssef Y, De Wet D, Back DA, Scherer J. Digitalization in orthopaedics: a narrative review. Front Surg 2024; 10:1325423. [PMID: 38274350 PMCID: PMC10808497 DOI: 10.3389/fsurg.2023.1325423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 12/27/2023] [Indexed: 01/27/2024] Open
Abstract
Advances in technology and digital tools like the Internet of Things (IoT), artificial intelligence (AI), and sensors are shaping the field of orthopaedic surgery on all levels, from patient care to research and facilitation of logistic processes. Especially the COVID-19 pandemic, with the associated contact restrictions was an accelerator for the development and introduction of telemedical applications and digital alternatives to classical in-person patient care. Digital applications already used in orthopaedic surgery include telemedical support, online video consultations, monitoring of patients using wearables, smart devices, surgical navigation, robotic-assisted surgery, and applications of artificial intelligence in forms of medical image processing, three-dimensional (3D)-modelling, and simulations. In addition to that immersive technologies like virtual, augmented, and mixed reality are increasingly used in training but also rehabilitative and surgical settings. Digital advances can therefore increase the accessibility, efficiency and capabilities of orthopaedic services and facilitate more data-driven, personalized patient care, strengthening the self-responsibility of patients and supporting interdisciplinary healthcare providers to offer for the optimal care for their patients.
Collapse
Affiliation(s)
- Yasmin Youssef
- Department of Orthopaedics, Trauma and Plastic Surgery, University Hospital of Leipzig, Leipzig, Germany
| | - Deana De Wet
- Orthopaedic Research Unit, University of Cape Town, Cape Town, South Africa
| | - David A. Back
- Center for Musculoskeletal Surgery, Charité University Medicine Berlin, Berlin, Germany
| | - Julian Scherer
- Orthopaedic Research Unit, University of Cape Town, Cape Town, South Africa
- Department of Traumatology, University Hospital of Zurich, Zurich, Switzerland
| |
Collapse
|
9
|
Labus KM, Wolynski J, Easley J, Stewart HL, Ilic M, Notaros B, Zagrocki T, Puttlitz CM, McGilvray KC. Employing direct electromagnetic coupling to assess acute fracture healing: An ovine model assessment. Injury 2023; 54:111080. [PMID: 37802738 PMCID: PMC10843464 DOI: 10.1016/j.injury.2023.111080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/13/2023] [Accepted: 09/26/2023] [Indexed: 10/08/2023]
Abstract
OBJECTIVES This study explored the efficacy of collecting temporal fracture site compliance data via an advanced direct electromagnetic coupling (DEC) system equipped with a Vivaldi-type antenna, novel calibration technique, and multi-antenna setup (termed maDEC) as an approach to monitor acute fracture healing progress in a translational large animal model. The overarching goal of this approach was to provide insights into the acute healing dynamics, offering a promising avenue for optimizing fracture management strategies. METHODS A sample of twelve sheep, subjected to ostectomies and intramedullary nail fixations, was divided into two groups, simulating normal and impaired healing scenarios. Sequential maDEC compliance or stiffness measurements and radiographs were taken from the surgery until euthanasia at four or eight weeks and were subsequently compared with post-sacrifice biomechanical, micro-CT, and histological findings. RESULTS The results showed that the maDEC system offered straightforward quantification of fracture site compliance via a multiantenna array. Notably, the rate of change in the maDEC-measured bending stiffness significantly varied between normal and impaired healing groups during both the 4-week (p = 0.04) and 8-week (p = 0.02) periods. In contrast, radiographically derived mRUST healing measurements displayed no significant differences between the groups (p = 0.46). Moreover, the cumulative normalized stiffness maDEC data significantly correlated with post-sacrifice mechanical strength (r2 = 0.80, p < 0.001), micro-CT measurements of bone volume fraction (r2 = 0.60, p = 0.003), and density (r2 = 0.60, p = 0.003), and histomorphometric measurements of new bone area fraction (r2 = 0.61, p = 0.003) and new bone area (r2 = 0.60, p < 0.001). CONCLUSIONS These data indicate that the enhanced maDEC system provides a non-invasive, accurate method to monitor fracture healing during the acute healing phase, showing distinct stiffness profiles between normal and impaired healing groups and offering critical insights into the healing process's progress and efficiency.
Collapse
Affiliation(s)
- Kevin M Labus
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Jakob Wolynski
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Jeremiah Easley
- Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Holly L Stewart
- Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Milan Ilic
- University of Belgrade, School of Electrical Engineering, Belgrade, Serbia
| | - Branislav Notaros
- Electromagnetic Laboratory, Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, Colorado, USA
| | - Taylor Zagrocki
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Christian M Puttlitz
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Kirk C McGilvray
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA.
| |
Collapse
|
10
|
Yocum D, Elashoff B, Verta P, Armock G, Yergler J. Patient reported outcomes do not correlate to functional knee recovery and range of motion in total knee arthroplasty. J Orthop 2023; 43:36-40. [PMID: 37564705 PMCID: PMC10409997 DOI: 10.1016/j.jor.2023.07.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 07/12/2023] [Accepted: 07/14/2023] [Indexed: 08/12/2023] Open
Abstract
Background Many total knee arthroplasty (TKA) patients exhibit continued pain and limited function following surgery. Determining TKA outcomes is typically reliant on post-operative evaluations and completing patient-reported outcomes (PROMs). Due to low compliance rates, it is essential to identify new strategies for monitoring patients. The purpose of this analysis was to assess the correlations between gait kinematics, PROMs, and knee range of motion (ROM). Methods 130 patients (75 female) received Persona IQ TKA (Zimmer Biomet, Warsaw, IN, USA) which includes a stem extension with embedded accelerometer and gyroscope. PROM scores were compared at baseline and 6 weeks post-TKA using a paired t-test. Gait kinematics were recorded daily via the Persona IQ stem extension. Pearson's correlation coefficients were derived between PROMs and average gait kinematics. Results Knee Injury and Osteoarthritis Outcome Score (KOOS Jr.) and Veterans RAND 12 (VR-12) physical scores improved following surgery (p ≤ 0.001, p = 0.003, respectively). Weak statistically significant correlations were found between PROMS and gait kinematics. Conclusion Weak correlations between PROMs and gait kinematics indicate patient perception of improvement and objectively measured functional status may not be interchangeable. Further, compliance with Persona IQ data reached 95.4-97.7% (depending on the parameter) at 6 weeks following surgery, a 20% higher compliance rate over PROMs. Daily functional measurements provide insight into the patient's progression and may be useful in detecting poor outcomes.
Collapse
Affiliation(s)
- Derek Yocum
- South Bend Orthopaedics, 53880 Carmichael Dr., South Bend, IN, 46635, USA
| | | | - Patrick Verta
- Canary Medical, 2710 Loker Ave W, Carlsbad, CA, 92010, USA
| | - Gary Armock
- South Bend Orthopaedics, 53880 Carmichael Dr., South Bend, IN, 46635, USA
| | - Jeffrey Yergler
- South Bend Orthopaedics, 53880 Carmichael Dr., South Bend, IN, 46635, USA
| |
Collapse
|
11
|
Jeyaraman M, Jayakumar T, Jeyaraman N, Nallakumarasamy A. Sensor Technology in Fracture Healing. Indian J Orthop 2023; 57:1196-1202. [PMID: 37525725 PMCID: PMC10386990 DOI: 10.1007/s43465-023-00933-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Accepted: 06/08/2023] [Indexed: 08/02/2023]
Abstract
Introduction SMART sensor technology may provide the solution to bridge the gap between the current radiographic determination of fracture healing and clinical assessment. The displacement and rigidity between the fracture ends can be accurately measured using strain gauges. Progressively increasing stiffness is a sign of fracture consolidation which can be monitored using sensors. The design of standard orthopaedic implants can remain the same and needs no major modifications as the sensor can be mounted onto the implant without occupying much space. Data regarding various fracture morphologies and their strain levels throughout the fracture healing process may help develop AI algorithms that can subsequently be used to optimise implant design/materials. Materials and Methods The literature search was performed in PubMed, PubMed Central, Scopus, and Web of Science databases for reviewing and evaluating the published scientific data regarding sensor technology in fracture healing. Results and Interpretation SMART sensor technology comes with a variety of uses such as determining fracture healing progress, predicting early implant failure, and determining fractures liable for non-union to exemplify a few. The main limitations are that it is still in its inception and needs extensive refinement before it becomes widely and routinely used in clinical practice. Nevertheless, with continuous advances in microprocessor technology, research designs, and additive manufacturing, the utilisation and application of SMART implants in the field of trauma and orthopaedic surgery are constantly growing. Conclusion Mass production of such SMART implants will reduce overall production costs and see its use in routine clinical practice in the future and is likely to make a significant contribution in the next industrial revolution termed 'Industry 5.0' which aims at personalised patient-specific implants and devices. SMART sensor technology may, therefore, herald a new era in the field of orthopaedic trauma.
Collapse
Affiliation(s)
- Madhan Jeyaraman
- Department of Orthopaedics, ACS Medical College and Hospital, Dr MGR Educational and Research Institute, Chennai, Tamil Nadu 600056 India
| | - Tarun Jayakumar
- Department of Orthopaedics, KIMS-Sunshine Hospital, Hyderabad, Telangana 500003 India
| | - Naveen Jeyaraman
- Department of Orthopaedics, Shri Sathya Sai Medical College and Research Institute, Sri Balaji Vidyapeeth, Chengalpattu, Tamil Nadu 603108 India
| | - Arulkumar Nallakumarasamy
- Department of Orthopaedics, All India Institute of Medical Sciences, Bhubaneswar, Odisha 751019 India
| |
Collapse
|
12
|
Tovar-Lopez FJ. Recent Progress in Micro- and Nanotechnology-Enabled Sensors for Biomedical and Environmental Challenges. SENSORS (BASEL, SWITZERLAND) 2023; 23:5406. [PMID: 37420577 DOI: 10.3390/s23125406] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/01/2023] [Accepted: 06/05/2023] [Indexed: 07/09/2023]
Abstract
Micro- and nanotechnology-enabled sensors have made remarkable advancements in the fields of biomedicine and the environment, enabling the sensitive and selective detection and quantification of diverse analytes. In biomedicine, these sensors have facilitated disease diagnosis, drug discovery, and point-of-care devices. In environmental monitoring, they have played a crucial role in assessing air, water, and soil quality, as well as ensured food safety. Despite notable progress, numerous challenges persist. This review article addresses recent developments in micro- and nanotechnology-enabled sensors for biomedical and environmental challenges, focusing on enhancing basic sensing techniques through micro/nanotechnology. Additionally, it explores the applications of these sensors in addressing current challenges in both biomedical and environmental domains. The article concludes by emphasizing the need for further research to expand the detection capabilities of sensors/devices, enhance sensitivity and selectivity, integrate wireless communication and energy-harvesting technologies, and optimize sample preparation, material selection, and automated components for sensor design, fabrication, and characterization.
Collapse
|
13
|
Kulkarni PG, Paudel N, Magar S, Santilli MF, Kashyap S, Baranwal AK, Zamboni P, Vasavada P, Katiyar A, Singh AV. Overcoming Challenges and Innovations in Orthopedic Prosthesis Design: An Interdisciplinary Perspective. BIOMEDICAL MATERIALS & DEVICES (NEW YORK, N.Y.) 2023:1-12. [PMID: 37363137 PMCID: PMC10180679 DOI: 10.1007/s44174-023-00087-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 04/29/2023] [Indexed: 06/28/2023]
Abstract
Recent advances in the orthopedic prostheses design have significantly improved the quality of life for individuals with orthopedic disabilities. However, there are still critical challenges that need to be addressed to further enhance the functionality of orthopedic prostheses improving biocompatibility to promote better integration with natural tissues, enhancing durability to withstand the demands of daily use, and improving sensory feedback for better control of movement are the most pressing issues. To address these challenges, promising emerging solutions such as smart prosthetics, 3D printing, regenerative medicine, and artificial intelligence have been developed. These innovative technologies hold the potential to significantly enhance the functionality of orthopedic prostheses. Realizing the full potential of these next-generation orthopedic prostheses requires addressing several critical factors. These include interdisciplinary collaboration between experts in orthopedics, materials science, biology, and engineering, increased investment in research and development, standardization of components to ensure quality and reliability, and improved access to prosthetics. A comprehensive review of these challenges and considerations for future orthopedic prosthesis design is s provided in this paper addressing the further advances to the field. By addressing these issues, we can continue to improve the lives of individuals with orthopedic disabilities and further enhance the field of orthopedic prosthetics.
Collapse
Affiliation(s)
| | - Namuna Paudel
- Department of Chemistry, Amrit Campus, Institute of Science and Technology, Tribhuvan University, Lainchaur, Kathmandu, 44600 Nepal
| | - Shilpa Magar
- Seeta Nursing Home, Shivaji Nagar, Nashik, Maharashtra 422002 India
| | | | | | | | - Paolo Zamboni
- Chair Vascular Diseases Center, University of Ferrara, 44124 Ferrara, Italy
| | - Priyank Vasavada
- M.S. Ramaiah Medical College and Hospital, Bengaluru, 560054 India
| | - Aman Katiyar
- Jain University, Bengaluru, Karnataka 560069 India
| | - Ajay Vikram Singh
- Department of Chemical and Product Safety, German Federal Institute of Risk Assessment (BfR), Maxdohrnstrasse 8-10, 10589 Berlin, Germany
| |
Collapse
|
14
|
Zhang Y, Cui J, Chen KY, Kuo SH, Sharma J, Bhatta R, Liu Z, Ellis-Mohr A, An F, Li J, Chen Q, Foss KD, Wang H, Li Y, McCoy AM, Lau GW, Cao Q. A smart coating with integrated physical antimicrobial and strain-mapping functionalities for orthopedic implants. SCIENCE ADVANCES 2023; 9:eadg7397. [PMID: 37146142 PMCID: PMC10162669 DOI: 10.1126/sciadv.adg7397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 04/04/2023] [Indexed: 05/07/2023]
Abstract
The prevalence of orthopedic implants is increasing with an aging population. These patients are vulnerable to risks from periprosthetic infections and instrument failures. Here, we present a dual-functional smart polymer foil coating compatible with commercial orthopedic implants to address both septic and aseptic failures. Its outer surface features optimum bioinspired mechano-bactericidal nanostructures, capable of killing a wide spectrum of attached pathogens through a physical process to reduce the risk of bacterial infection, without directly releasing any chemicals or harming mammalian cells. On its inner surface in contact with the implant, an array of strain gauges with multiplexing transistors, built on single-crystalline silicon nanomembranes, is incorporated to map the strain experienced by the implant with high sensitivity and spatial resolution, providing information about bone-implant biomechanics for early diagnosis to minimize the probability of catastrophic instrument failures. Their multimodal functionalities, performance, biocompatibility, and stability are authenticated in sheep posterolateral fusion model and rodent implant infection model.
Collapse
Affiliation(s)
- Yi Zhang
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Jinsong Cui
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Kuan-Yu Chen
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Shanny Hsuan Kuo
- Department of Pathobiology, University of Illinois Urbana-Champaign, Urbana, IL 61802, USA
| | - Jaishree Sharma
- Department of Pathobiology, University of Illinois Urbana-Champaign, Urbana, IL 61802, USA
| | - Rimsha Bhatta
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Zheng Liu
- Department of Industrial and Enterprise Systems Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Austin Ellis-Mohr
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Fufei An
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Jiahui Li
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Qian Chen
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Kari D. Foss
- Department of Veterinary Clinical Medicine, University of Illinois Urbana-Champaign. Urbana, IL 61802, USA
- Veterinary Teaching Hospital, University of Illinois Urbana-Champaign, Urbana, IL 61802, USA
| | - Hua Wang
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Yumeng Li
- Department of Industrial and Enterprise Systems Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Annette M. McCoy
- Department of Veterinary Clinical Medicine, University of Illinois Urbana-Champaign. Urbana, IL 61802, USA
- Veterinary Teaching Hospital, University of Illinois Urbana-Champaign, Urbana, IL 61802, USA
| | - Gee W. Lau
- Department of Pathobiology, University of Illinois Urbana-Champaign, Urbana, IL 61802, USA
| | - Qing Cao
- Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
- Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
- Frederick Seitz Materials Research Laboratory, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
- Holonyak Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
15
|
Remote Patient Monitoring Following Total Joint Arthroplasty. Orthop Clin North Am 2023; 54:161-168. [PMID: 36894289 DOI: 10.1016/j.ocl.2022.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
This review article presents the current state of remote patient monitoring (RPM) in total joint arthroplasty. RPM refers to the use of telecommunication with wearable and implantable technology to assess and treat patients. Several forms of RPM are discussed including telemedicine, patient engagement platforms, wearable devices, and implantable devices. The benefits to patients and physicians are discussed in the context of postoperative monitoring. Insurance coverage and reimbursement of these technologies are reviewed.
Collapse
|
16
|
Won SM, Cai L, Gutruf P, Rogers JA. Wireless and battery-free technologies for neuroengineering. Nat Biomed Eng 2023; 7:405-423. [PMID: 33686282 PMCID: PMC8423863 DOI: 10.1038/s41551-021-00683-3] [Citation(s) in RCA: 96] [Impact Index Per Article: 96.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Accepted: 12/28/2020] [Indexed: 12/16/2022]
Abstract
Tethered and battery-powered devices that interface with neural tissues can restrict natural motions and prevent social interactions in animal models, thereby limiting the utility of these devices in behavioural neuroscience research. In this Review Article, we discuss recent progress in the development of miniaturized and ultralightweight devices as neuroengineering platforms that are wireless, battery-free and fully implantable, with capabilities that match or exceed those of wired or battery-powered alternatives. Such classes of advanced neural interfaces with optical, electrical or fluidic functionality can also combine recording and stimulation modalities for closed-loop applications in basic studies or in the practical treatment of abnormal physiological processes.
Collapse
Affiliation(s)
- Sang Min Won
- Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, South Korea
| | - Le Cai
- Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ, USA
| | - Philipp Gutruf
- Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ, USA.
- Bio5 Institute and Neuroscience GIDP, University of Arizona, Tucson, AZ, USA.
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ, USA.
| | - John A Rogers
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, USA.
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
- Center for Advanced Molecular Imaging, Northwestern University, Evanston, IL, USA.
- Department of Mechanical Engineering, Northwestern University, Evanston, IL, USA.
- Department of Chemistry, Northwestern University, Evanston, IL, USA.
- Department of Neurological Surgery, Northwestern University, Evanston, IL, USA.
- Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL, USA.
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Evanston, IL, USA.
| |
Collapse
|
17
|
Gait Analysis to Monitor Fracture Healing of the Lower Leg. Bioengineering (Basel) 2023; 10:bioengineering10020255. [PMID: 36829749 PMCID: PMC9952799 DOI: 10.3390/bioengineering10020255] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/07/2023] [Accepted: 02/13/2023] [Indexed: 02/17/2023] Open
Abstract
Fracture healing is typically monitored by infrequent radiographs. Radiographs come at the cost of radiation exposure and reflect fracture healing with a time lag due to delayed fracture mineralization following increases in stiffness. Since union problems frequently occur after fractures, better and timelier methods to monitor the healing process are required. In this review, we provide an overview of the changes in gait parameters following lower leg fractures to investigate whether gait analysis can be used to monitor fracture healing. Studies assessing gait after lower leg fractures that were treated either surgically or conservatively were included. Spatiotemporal gait parameters, kinematics, kinetics, and pedography showed improvements in the gait pattern throughout the healing process of lower leg fractures. Especially gait speed and asymmetry measures have a high potential to monitor fracture healing. Pedographic measurements showed differences in gait between patients with and without union. No literature was available for other gait measures, but it is expected that further parameters reflect progress in bone healing. In conclusion, gait analysis seems to be a valuable tool for monitoring the healing process and predicting the occurrence of non-union of lower leg fractures.
Collapse
|
18
|
Jalalah M, Ahmad A, Saleem A, Qadir MB, Khaliq Z, Khan MQ, Nazir A, Faisal M, Alsaiari M, Irfan M, Alsareii SA, Harraz FA. Electrospun Nanofiber/Textile Supported Composite Membranes with Improved Mechanical Performance for Biomedical Applications. MEMBRANES 2022; 12:membranes12111158. [PMID: 36422150 PMCID: PMC9693054 DOI: 10.3390/membranes12111158] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 11/03/2022] [Accepted: 11/11/2022] [Indexed: 05/27/2023]
Abstract
Textile-supported nanocomposite as a scaffold has been extensively used in the medical field, mainly to give support to weak or harmed tissues. However, there are some challenges in fabricating the nanofiber/textile composite, i.e., suitable porous structure with defined pore size, less skin contact area, biocompatibility, and availability of degradable materials. Herein, polyamide-6 (PA) nanofibers were synthesized using needleless electrospinning with the toothed wheel as a spinneret. The electrospinning process was optimized using different process and solution parameters. In the next phase, optimized PA nanofiber membranes of optimum fiber diameter with uniform distribution and thickness were used in making nanofiber membrane-textile composite. Different textile fabrics (woven, non-woven, knitted) were developed. The optimized nanofiber membranes were combined with non-woven, woven, and knitted fabrics to make fabric-supported nanocomposite. The nanofiber/fabric composites were compared with available market woven and knitted meshes for mechanical properties, morphology, structure, and chemical interaction analysis. It was found that the tear strength of the nanofiber/woven composite was three times higher than market woven mesh, and the nanofiber/knitted composite was 2.5 times higher than market knitted mesh. The developed composite structures with woven and knitted fabric exhibited improved bursting strength (613.1 and 751.1 Kpa), tensile strength (195.76 and 227.85 N), and puncture resistance (68.76 and 57.47 N), respectively, than market available meshes. All these properties showed that PA nanofibers/textile structures could be utilized as a composite with multifunctional properties.
Collapse
Affiliation(s)
- Mohammed Jalalah
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, Najran 11001, Saudi Arabia
- Department of Electrical Engineering, College of Engineering, Najran University, Najran 61441, Saudi Arabia
| | - Adnan Ahmad
- Department of Textile Engineering, National Textile University, Faisalabad 37610, Pakistan
| | - Asad Saleem
- Department of Textile Engineering, National Textile University, Faisalabad 37610, Pakistan
| | - Muhammad Bilal Qadir
- Department of Textile Engineering, National Textile University, Faisalabad 37610, Pakistan
| | - Zubair Khaliq
- Department of Materials, National Textile University, Faisalabad 37610, Pakistan
| | - Muhammad Qamar Khan
- Department of Textile & Clothing, Karachi Campus, National Textile University, Karachi 74900, Pakistan
| | - Ahsan Nazir
- Department of Textile Engineering, National Textile University, Faisalabad 37610, Pakistan
| | - M. Faisal
- Department of Chemistry, Faculty of Science and Arts, Najran University, Najran 11001, Saudi Arabia
| | - Mabkhoot Alsaiari
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, Najran 11001, Saudi Arabia
- Department of Chemistry, Faculty of Science and Arts at Sharurah, Najran University, Najran 11001, Saudi Arabia
| | - Muhammad Irfan
- Department of Electrical Engineering, College of Engineering, Najran University, Najran 61441, Saudi Arabia
| | - S. A. Alsareii
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, Najran 11001, Saudi Arabia
- Department of Surgery, College of Medicine, Najran University, Najran 11001, Saudi Arabia
| | - Farid A. Harraz
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, Najran 11001, Saudi Arabia
- Department of Chemistry, Faculty of Science and Arts at Sharurah, Najran University, Najran 11001, Saudi Arabia
| |
Collapse
|
19
|
Merle G, Miclau T, Parent-Harvey A, Harvey EJ. Sensor technology usage in orthopedic trauma. Injury 2022; 53 Suppl 3:S59-S63. [PMID: 36182592 DOI: 10.1016/j.injury.2022.09.036] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Revised: 08/25/2022] [Accepted: 09/08/2022] [Indexed: 02/02/2023]
Abstract
Medicine in general is quickly transitioning to a digital presence. Orthopaedic surgery is also being impacted by the tenets of digital health but there are also direct efforts with trauma surgery. Sensors are the pen and paper of the next wave of data acquisition. Orthopaedic trauma can and will be part of this new wave of medicine. Early sensor products that are now coming to market, or are in early development, will directly change the way we think about surgical diagnosis and outcomes. Sensor development for biometrics is already here. Wellness devices, pressure, temperature, and other parameters are already being measured. Data acquisition and analysis is going to be a fruitful addition to our research armamentarium with the volume of information now available. A combination of broadband internet, micro electrical machine systems (MEMS), and new wireless communication standards is driving this new wave of medicine. The Internet of Things (IoT) [1] now has a subset which is the Internet of Medical Devices [2-5] permitting a much more in-depth dive into patient procedures and outcomes. IoT devices are now being used to enable remote health monitoring, in hospital treatment, and guide therapies. This article reviews current sensor technology that looks to impact trauma care.
Collapse
Affiliation(s)
- Géraldine Merle
- École Polytechnique de Montréal, Université de Montréal, Montréal, Canada
| | - Theodore Miclau
- Orthopaedic Trauma Institute, University of Calfornia, School of Medicine, Department of Orthopaedics, San Francisco, USA
| | | | | |
Collapse
|
20
|
Rouf S, Malik A, Raina A, Irfan Ul Haq M, Naveed N, Zolfagharian A, Bodaghi M. Functionally graded additive manufacturing for orthopedic applications. J Orthop 2022; 33:70-80. [PMID: 35874041 PMCID: PMC9304666 DOI: 10.1016/j.jor.2022.06.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/22/2022] [Accepted: 06/27/2022] [Indexed: 11/20/2022] Open
Abstract
Background Additive Manufacturing due to its benefits in developing parts with complex geometries and shapes, has evolved as an alternate manufacturing process to develop implants with desired properties. The structure of human bones being anisotropic in nature is biologically functionally graded i,e. The structure possesses different properties in different directions. Therefore, various orthopedic implants such as knee, hip and other bone plates, if functionally graded can perform better. In this context, the development of functionally graded (FG) parts for orthopedic application with tailored anisotropic properties has become easier through the use of additive manufacturing (AM). Objectives and Rationale: The current paper aims to study the various aspects of additively manufactured FG parts for orthopedic applications. It presents the details of various orthopedic implants such as knee, hip and other bone plates in a structured manner. A systematic literature review is conducted to study the various material and functional aspects of functionally graded parts for orthopedic applications. A section is also dedicated to discuss the mechanical properties of functionally graded parts. Conclusion The literature revealed that additive manufacturing can provide lot of opportunities for development of functionally graded orthopedic implants with improved properties and durability. Further, the effect of various FG parameters on the mechanical behavior of these implants needs to be studied in detail. Also, with the advent of various AM technologies, the functional grading can be achieved by various means e.g. density, porosity, microstructure, composition, etc. By varying the AM parameters. However, the current limitations of cost and material biocompatibility prevent the widespread exploitation of AM technologies for various orthopedic applications.
Collapse
Affiliation(s)
- Saquib Rouf
- School of Mechanical Engineering, Shri Mata Vaishno Devi University, J&K, India
| | - Abrar Malik
- School of Mechanical Engineering, Shri Mata Vaishno Devi University, J&K, India
| | - Ankush Raina
- School of Mechanical Engineering, Shri Mata Vaishno Devi University, J&K, India
| | - Mir Irfan Ul Haq
- School of Mechanical Engineering, Shri Mata Vaishno Devi University, J&K, India
| | - Nida Naveed
- Faculty of Technology, University of Sunderland, UK
| | | | - Mahdi Bodaghi
- School of Science and Technology, Nottingham Trent University, UK
| |
Collapse
|
21
|
Veletić M, Apu EH, Simić M, Bergsland J, Balasingham I, Contag CH, Ashammakhi N. Implants with Sensing Capabilities. Chem Rev 2022; 122:16329-16363. [PMID: 35981266 DOI: 10.1021/acs.chemrev.2c00005] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Because of the aging human population and increased numbers of surgical procedures being performed, there is a growing number of biomedical devices being implanted each year. Although the benefits of implants are significant, there are risks to having foreign materials in the body that may lead to complications that may remain undetectable until a time at which the damage done becomes irreversible. To address this challenge, advances in implantable sensors may enable early detection of even minor changes in the implants or the surrounding tissues and provide early cues for intervention. Therefore, integrating sensors with implants will enable real-time monitoring and lead to improvements in implant function. Sensor integration has been mostly applied to cardiovascular, neural, and orthopedic implants, and advances in combined implant-sensor devices have been significant, yet there are needs still to be addressed. Sensor-integrating implants are still in their infancy; however, some have already made it to the clinic. With an interdisciplinary approach, these sensor-integrating devices will become more efficient, providing clear paths to clinical translation in the future.
Collapse
Affiliation(s)
- Mladen Veletić
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ehsanul Hoque Apu
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Division of Hematology and Oncology, Department of Internal Medicine, Michigan Medicine, University of Michigan, Ann Arbor, Michigan 48105, United States
| | - Mitar Simić
- Faculty of Electrical Engineering, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
| | - Jacob Bergsland
- The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Ilangko Balasingham
- Department of Electronic Systems, Norwegian University of Science and Technology, 7491 Trondheim, Norway.,The Intervention Centre, Technology and Innovation Clinic, Oslo University Hospital, 0372 Oslo, Norway
| | - Christopher H Contag
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States
| | - Nureddin Ashammakhi
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, Michigan 48824, United States.,Department of Bioengineering, University of California, Los Angeles, California 90095, United States
| |
Collapse
|
22
|
Ganse B, Orth M, Roland M, Diebels S, Motzki P, Seelecke S, Kirsch SM, Welsch F, Andres A, Wickert K, Braun BJ, Pohlemann T. Concepts and clinical aspects of active implants for the treatment of bone fractures. Acta Biomater 2022; 146:1-9. [PMID: 35537678 DOI: 10.1016/j.actbio.2022.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 04/24/2022] [Accepted: 05/02/2022] [Indexed: 12/17/2022]
Abstract
Nonunion is a complication of long bone fractures that leads to disability, morbidity and high costs. Early detection is difficult and treatment through external stimulation and revision surgery is often a lengthy process. Therefore, alternative diagnostic and therapeutic options are currently being explored, including the use of external and internal sensors. Apart from monitoring fracture stiffness and displacement directly at the fracture site, it would be desirable if an implant could also vary its stiffness and apply an intervention to promote healing, if needed. This could be achieved either by a predetermined protocol, by remote control, or even by processing data and triggering the intervention itself (self-regulated 'intelligent' or 'smart' implant). So-called active or smart materials like shape memory alloys (SMA) have opened up opportunities to build active implants. For example, implants could stimulate fracture healing by active shortening and lengthening via SMA actuator wires; by emitting pulses, waves, or electromagnetic fields. However, it remains undefined which modes of application, forces, frequencies, force directions, time durations and periods, or other stimuli such implants should ideally deliver for the best result. The present paper reviews the literature on active implants and interventions for nonunion, discusses possible mechanisms of active implants and points out where further research and development are needed to build an active implant that applies the most ideal intervention. STATEMENT OF SIGNIFICANCE: Early detection of delays during fracture healing and timely intervention are difficult due to limitations of the current diagnostic strategies. New diagnostic options are under evaluation, including the use of external and internal sensors. In addition, it would be desirable if an implant could actively facilitate healing ('Intelligent' or 'smart' implant). Implants could stimulate fracture healing via active shortening and lengthening; by emitting pulses, waves, or electromagnetic fields. No such implants exist to date, but new composite materials and alloys have opened up opportunities to build such active implants, and several groups across the globe are currently working on their development. The present paper is the first review on this topic to date.
Collapse
|
23
|
Nash KE, Ong KG, Guldberg RE. Implantable biosensors for musculoskeletal health. Connect Tissue Res 2022; 63:228-242. [PMID: 35172654 PMCID: PMC8977250 DOI: 10.1080/03008207.2022.2041002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE A healthy musculoskeletal system requires complex functional integration of bone, muscle, cartilage, and connective tissues responsible for bodily support, motion, and the protection of vital organs. Conditions or injuries to musculoskeeltal tissues can devastate an individual's quality of life. Some conditions that are particularly disabling include severe bone and muscle injuries to the extremities and amputations resulting from unmanageable musculoskeletal conditions or injuries. Monitoring and managing musculoskeletal health is intricate because of the complex mechanobiology of these interconnected tissues. METHODS For this article, we reviewed literature on implantable biosensors related to clinical data of the musculoskeletal system, therapeutics for complex bone injuries, and osseointegrated prosthetics as example applications. RESULTS As a result, a brief summary of biosensors technologies is provided along with review of noteworthy biosensors and future developments needed to fully realize the translational benefit of biosensors for musculoskeletal health. CONCLUSIONS Novel implantable biosensors capable of tracking biophysical parameters in vivo are highly relevant to musculoskeletal health because of their ability to collect clinical data relevant to medical decisions, complex trauma treatment, and the performance of osseointegrated prostheses.
Collapse
Affiliation(s)
- Kylie E. Nash
- Phil and Penny Knight Campus for Accelerating Scientific Impact Department of Bioengineering, University of Oregon, Eugene, OR 97403
| | - Keat Ghee Ong
- Phil and Penny Knight Campus for Accelerating Scientific Impact Department of Bioengineering, University of Oregon, Eugene, OR 97403
| | - Robert E. Guldberg
- Phil and Penny Knight Campus for Accelerating Scientific Impact Department of Bioengineering, University of Oregon, Eugene, OR 97403,Corresponding Author: Robert E. Guldberg, Ph.D., 3231 University of Oregon, Eugene OR, 97403,
| |
Collapse
|
24
|
Shen YW, Yang Y, Liu H, Qiu Y, Li M, Ma LT, Gan FJ. Biomechanical Evaluation of Intervertebral Fusion Process After Anterior Cervical Discectomy and Fusion: A Finite Element Study. Front Bioeng Biotechnol 2022; 10:842382. [PMID: 35372323 PMCID: PMC8969047 DOI: 10.3389/fbioe.2022.842382] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 02/15/2022] [Indexed: 12/25/2022] Open
Abstract
Introduction: Anterior cervical discectomy and fusion (ACDF) is a widely accepted surgical procedure in the treatment of cervical radiculopathy and myelopathy. A solid interbody fusion is of critical significance in achieving satisfactory outcomes after ACDF. However, the current radiographic techniques to determine the degree of fusion are inaccurate and radiative. Several animal experiments suggested that the mechanical load on the spinal instrumentation could reflect the fusion process and evaluated the stability of implant. This study aims to investigate the biomechanical changes during the fusion process and explore the feasibility of reflecting the fusion status after ACDF through the load changes borne by the interbody fusion cage. Methods: The computed tomography (CT) scans preoperatively, immediately after surgery, at 3 months, and 6 months follow-up of patients who underwent ACDF at C5/6 were used to construct the C2–C7 finite element (FE) models representing different courses of fusion stages. A 75-N follower load with 1.0-Nm moments was applied to the top of C2 vertebra in the models to simulate flexion, extension, lateral bending, and axial rotation with the C7 vertebra fixed. The Von Mises stress at the surfaces of instrumentation and the adjacent intervertebral disc and force at the facet joints were analyzed. Results: The facet contact force at C5/6 suggested a significantly stepwise reduction as the fusion proceeded while the intradiscal pressure and facet contact force of adjacent levels changed slightly. The stress on the surfaces of titanium plate and screws significantly decreased at 3 and 6 months follow-up. A markedly changed stress distribution in extension among three models was noted in different fusion stages. After solid fusion is achieved, the stress was more uniformly distributed interbody fusion in all loading conditions. Conclusions: Through a follow-up study of 6 months, the stress on the surfaces of cervical instrumentation remarkably decreased in all loading conditions. After solid intervertebral fusion formed, the stress distributions on the surfaces of interbody cage and screws were more uniform. The stress distribution in extension altered significantly in different fusion status. Future studies are needed to develop the interbody fusion device with wireless sensors to achieve longitudinal real-time monitoring of the stress distribution during the course of fusion.
Collapse
Affiliation(s)
- Yi-Wei Shen
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Yi Yang
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Hao Liu
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
- *Correspondence: Hao Liu,
| | - Yue Qiu
- West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, China
| | - Ming Li
- Department of Measurement and Control Technology and Instrument, Sichuan University, Chengdu, China
| | - Li-Tai Ma
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, China
| | - Fang-Ji Gan
- Department of Measurement and Control Technology and Instrument, Sichuan University, Chengdu, China
| |
Collapse
|
25
|
Kim SJ, Wang T, Pelletier MH, Walsh WR. 'SMART' implantable devices for spinal implants: a systematic review on current and future trends. JOURNAL OF SPINE SURGERY (HONG KONG) 2022; 8:117-131. [PMID: 35441100 DOI: 10.21037/jss-21-100] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 02/28/2022] [Indexed: 01/18/2023]
Abstract
Background 'SMART' implants refer to modified orthopedic implants that combine the biomechanical safety and efficacy of traditional devices with the intelligence of data-logging sensors. This review aims to systematically assess the available literature on SMART spinal implants and present these findings in a clinically relevant manner. Methods A search of PubMed, Scopus, and Google Scholar databases was conducted by two separate reviewers. Information including sensor type, intended application, and sample size, was extracted from included studies. Risk of bias assessment was conducted using the Office of Health Assessment and Translation (OHAT) risk of bias tool. Results Eighteen studies were included for analysis. Eight studies involved SMART rods and ten studies used SMART vertebral body replacements (VBR). No more than 20 patients are reported to have received a SMART spinal implant. Including non-primary evidence, seven unique designs for SMART spinal implants were found. The majority of these used strain gauges with recent designs including thermometers and accelerometers. Discussion At present, SMART spinal implants have primarily focused on utilising strain gauges to report loading on the implant itself. This is a logical first step as it allows quantification of real-world requirements of an implant, detection of catastrophic failure, while also allowing researchers and clinicians to estimate changes in load sharing between newly forming bone and the implant itself, providing real-time information on the progression of healing and fusion. Future work includes documenting the correlation between data provided by these SMART implants and clinical findings, including complications such as pedicle screw loosening and interbody cage subsidence.
Collapse
Affiliation(s)
- Sihyong J Kim
- Faculty of Medicine, University of New South Wales (UNSW), Sydney, Australia.,Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| | - Tian Wang
- Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| | - Matthew H Pelletier
- Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| | - William R Walsh
- Surgical and Orthopaedics Research Laboratory, Prince of Wales Hospital, Randwick, NSW, Australia
| |
Collapse
|
26
|
Application and Development of Modern 3D Printing Technology in the Field of Orthopedics. BIOMED RESEARCH INTERNATIONAL 2022; 2022:8759060. [PMID: 35211626 PMCID: PMC8863440 DOI: 10.1155/2022/8759060] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 01/06/2022] [Accepted: 01/17/2022] [Indexed: 12/31/2022]
Abstract
3D printing, also known as additive manufacturing, is a technology that uses a variety of adhesive materials such as powdered metal or plastic to construct objects based on digital models. Recently, 3D printing technology has been combined with digital medicine, materials science, cytology, and other multidisciplinary fields, especially in the field of orthopedic built-in objects. The development of advanced 3D printing materials continues to meet the needs of clinical precision medicine and customize the most suitable prosthesis for everyone to improve service life and satisfaction. This article introduces the development of 3D printing technology and different types of materials. We also discuss the shortcomings of 3D printing technology and the current challenges, including the poor bionics of 3D printing products, lack of ideal bioinks, product safety, and lack of market supervision. We also prospect the future development trends of 3D printing.
Collapse
|
27
|
Evaluation of Bone Consolidation in External Fixation with an Electromechanical System. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12052328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The monitoring of fracture or osteotomy healing is vital for orthopedists to help advise, if necessary, secondary treatments for improving healing outcomes and minimizing patient suffering. It has been decades since osteotomy stiffness has been identified as one main parameter to quantify and qualify the outcome of a regenerated callus. Still, radiographic imaging remains the current standard diagnostic technique of orthopedists. Hence, with recent technological advancements, engineers need to use the new branches of knowledge and improve or innovate diagnostic technologies. An electromechanical system was developed to help diagnose changes in osteotomy stiffness treated with the external fixator LRS Orthofix®. The concept was evaluated experimentally and numerically during fracture healing simulation using two different models: a simplified model of a human tibia, consisting of a nylon bar with a diameter of 30 mm, and a synthetic tibia with the anatomical model from fourth-generation Sawbones®. Moreover, Sawbones® blocks with different densities simulated the mechanical characteristics of the regenerated bone in many stages of bone callus growth. The experimental measurements using the developed diagnostic were compared to the numerically simulated results. For this external fixator, it was possible to show that the displacement in osteotomy was always lower than the displacement prescribed in the elongator. Nevertheless, a relationship was established between the energy consumption by the electromechanical system used to perform callus stimulus and the degree of osteotomy consolidation. Hence, this technology may lead to methodologies of mechanical stimulation for regenerating bone, which will play a relevant role for bedridden individuals with mobility limitations.
Collapse
|
28
|
Loenen ACY, Noailly J, Ito K, Willems PC, Arts JJ, van Rietbergen B. Patient-Specific Variations in Local Strain Patterns on the Surface of a Trussed Titanium Interbody Cage. Front Bioeng Biotechnol 2022; 9:750246. [PMID: 35087797 PMCID: PMC8786731 DOI: 10.3389/fbioe.2021.750246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 12/21/2021] [Indexed: 11/13/2022] Open
Abstract
Introduction: 3D printed trussed titanium interbody cages may deliver bone stimulating mechanobiological strains to cells attached at their surface. The exact size and distribution of these strains may depend on patient-specific factors, but the influence of these factors remains unknown. Therefore, this study aimed to determine patient-specific variations in local strain patterns on the surface of a trussed titanium interbody fusion cage.Materials and Methods: Four patients eligible for spinal fusion surgery with the same cage size were selected from a larger database. For these cases, patient-specific finite element models of the lumbar spine including the same trussed titanium cage were made. Functional dynamics of the non-operated lumbar spinal segments, as well as local cage strains and caudal endplate stresses at the operated segment, were evaluated under physiological extension/flexion movement of the lumbar spine.Results: All patient-specific models revealed physiologically realistic functional dynamics of the operated spine. In all patients, approximately 30% of the total cage surface experienced strain values relevant for preserving bone homeostasis and stimulating bone formation. Mean caudal endplate contact pressures varied up to 10 MPa. Both surface strains and endplate contact pressures varied more between loading conditions than between patients.Conclusions: This study demonstrates the applicability of patient-specific finite element models to quantify the impact of patient-specific factors such as bone density, degenerative state of the spine, and spinal curvature on interbody cage loading. In the future, the same framework might be further developed in order to establish a pipeline for interbody cage design optimizations.
Collapse
Affiliation(s)
- Arjan C. Y. Loenen
- Laboratory for Experimental Orthopaedics, Department of Orthopaedic Surgery, CAPHRI, Maastricht University Medical Center, Maastricht, Netherlands
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Jérôme Noailly
- Department of Information and Communication Technologies, BCN MedTech, Universitat Pompeu Fabra, Barcelona, Spain
| | - Keita Ito
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Paul C. Willems
- Laboratory for Experimental Orthopaedics, Department of Orthopaedic Surgery, CAPHRI, Maastricht University Medical Center, Maastricht, Netherlands
| | - Jacobus J. Arts
- Laboratory for Experimental Orthopaedics, Department of Orthopaedic Surgery, CAPHRI, Maastricht University Medical Center, Maastricht, Netherlands
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Bert van Rietbergen
- Laboratory for Experimental Orthopaedics, Department of Orthopaedic Surgery, CAPHRI, Maastricht University Medical Center, Maastricht, Netherlands
- Orthopaedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- *Correspondence: Bert van Rietbergen,
| |
Collapse
|
29
|
Schröder HC, Wang X, Neufurth M, Wang S, Müller WEG. Biomimetic Polyphosphate Materials: Toward Application in Regenerative Medicine. PROGRESS IN MOLECULAR AND SUBCELLULAR BIOLOGY 2022; 61:83-130. [PMID: 35697938 DOI: 10.1007/978-3-031-01237-2_5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In recent years, inorganic polyphosphate (polyP) has attracted increasing attention as a biomedical polymer or biomaterial with a great potential for application in regenerative medicine, in particular in the fields of tissue engineering and repair. The interest in polyP is based on two properties of this physiological polymer that make polyP stand out from other polymers: polyP has morphogenetic activity by inducing cell differentiation through specific gene expression, and it functions as an energy store and donor of metabolic energy, especially in the extracellular matrix or in the extracellular space. No other biopolymer applicable in tissue regeneration/repair is known that is endowed with this combination of properties. In addition, polyP can be fabricated both in the form of a biologically active coacervate and as biomimetic amorphous polyP nano/microparticles, which are stable and are activated by transformation into the coacervate phase after contact with protein/body fluids. PolyP can be used in the form of various metal salts and in combination with various hydrogel-forming polymers, whereby (even printable) hybrid materials with defined porosities and mechanical and biological properties can be produced, which can even be loaded with cells for 3D cell printing or with drugs and support the growth and differentiation of (stem) cells as well as cell migration/microvascularization. Potential applications in therapy of bone, cartilage and eye disorders/injuries and wound healing are summarized and possible mechanisms are discussed.
Collapse
Affiliation(s)
- Heinz C Schröder
- ERC Advanced Investigator Group, Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Xiaohong Wang
- ERC Advanced Investigator Group, Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Meik Neufurth
- ERC Advanced Investigator Group, Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Shunfeng Wang
- ERC Advanced Investigator Group, Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Mainz, Germany
| | - Werner E G Müller
- ERC Advanced Investigator Group, Institute for Physiological Chemistry, University Medical Center of the Johannes Gutenberg University, Mainz, Germany.
| |
Collapse
|
30
|
Yapp LZ, Robinson PG, Clement ND, Scott CEH. Total Knee Arthroplasty and Intra-Articular Pressure Sensors: Can They Assist Surgeons with Intra-Operative Decisions? Curr Rev Musculoskelet Med 2021; 14:361-368. [PMID: 34962638 PMCID: PMC8733123 DOI: 10.1007/s12178-021-09724-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/22/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW Soft tissue imbalance, presenting as instability or stiffness, is an important cause of revision total knee arthroplasty (TKA). Traditional methods of determining soft tissue balance of the knee lack precision and are not reliable between operators. Use of intra-operative pressure sensors offers the potential to identify and avoid soft tissue imbalance following TKA. This review aims to summarise the literature supporting the clinical indication for the use of intra-articular pressure sensors during TKA. RECENT FINDINGS Analytical validation studies suggest that intra-operative pressure sensors demonstrate 'moderate' to 'good' intra-observer reliability and 'good' to 'excellent' interobserver reliability throughout the flexion arc. However, there are important errors associated with measurements when devices are used out-with the stated guidelines and clinicians should be aware of the limitations of these devices in isolation. Current evidence regarding patient benefit is conflicting. Despite positive early results, several prospective studies have subsequently failed to demonstrate significant differences in overall survival, satisfaction, and patient-reported outcome measures within 1 year of surgery. Surgeon-defined soft tissue stability appears to be significantly different from the absolute pressures measured by the intra-operative sensor. Whilst it could be argued that this confirms the need for intra-articular sensor guidance in TKA; the optimal 'target' balance remains unclear and the relationship with outcome in patients is not determined. Future research should (1) identify a suitable reference standard for comparison; (2) improve the accuracy of the sensor outputs; and (3) demonstrate that sensor-assisted TKA leads to patient benefit in patient-reported outcome measures and/or enhanced implant survival.
Collapse
Affiliation(s)
- Liam Z. Yapp
- Department of Orthopaedics, Deanery of Clinical Sciences, University of Edinburgh, Chancellors Building, 49 Little France Crescent, Edinburgh, EH16 4SB UK
- Department of Trauma & Orthopaedic Surgery, Royal Infirmary of Edinburgh, NHS Lothian, 51 Little France Crescent, Edinburgh, EH16 4SY UK
| | - Patrick G. Robinson
- Department of Orthopaedics, Deanery of Clinical Sciences, University of Edinburgh, Chancellors Building, 49 Little France Crescent, Edinburgh, EH16 4SB UK
- Department of Trauma & Orthopaedic Surgery, Royal Infirmary of Edinburgh, NHS Lothian, 51 Little France Crescent, Edinburgh, EH16 4SY UK
| | - Nicholas D. Clement
- Department of Orthopaedics, Deanery of Clinical Sciences, University of Edinburgh, Chancellors Building, 49 Little France Crescent, Edinburgh, EH16 4SB UK
- Department of Trauma & Orthopaedic Surgery, Royal Infirmary of Edinburgh, NHS Lothian, 51 Little France Crescent, Edinburgh, EH16 4SY UK
| | - Chloe E. H. Scott
- Department of Orthopaedics, Deanery of Clinical Sciences, University of Edinburgh, Chancellors Building, 49 Little France Crescent, Edinburgh, EH16 4SB UK
- Department of Trauma & Orthopaedic Surgery, Royal Infirmary of Edinburgh, NHS Lothian, 51 Little France Crescent, Edinburgh, EH16 4SY UK
| |
Collapse
|
31
|
Shah NV, Gold R, Dar QA, Diebo BG, Paulino CB, Naziri Q. Smart Technology and Orthopaedic Surgery: Current Concepts Regarding the Impact of Smartphones and Wearable Technology on Our Patients and Practice. Curr Rev Musculoskelet Med 2021; 14:378-391. [PMID: 34729710 PMCID: PMC8733100 DOI: 10.1007/s12178-021-09723-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/17/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE OF REVIEW While limited to case reports or small case series, emerging evidence advocates the inclusion of smartphone-interfacing mobile platforms and wearable technologies, consisting of internet-powered mobile and wearable devices that interface with smartphones, in the orthopaedic surgery practice. The purpose of this review is to investigate the relevance and impact of this technology in orthopaedic surgery. RECENT FINDINGS Smartphone-interfacing mobile platforms and wearable technologies are capable of improving the patients' quality of life as well as the extent of their therapeutic engagement, while promoting the orthopaedic surgeons' abilities and level of care. Offered advantages include improvements in diagnosis and examination, preoperative templating and planning, and intraoperative assistance, as well as postoperative monitoring and rehabilitation. Supplemental surgical exposure, through haptic feedback and realism of audio and video, may add another perspective to these innovations by simulating the operative environment and potentially adding a virtual tactile feature to the operator's visual experience. Although encouraging in the field of orthopaedic surgery, surgeons should be cautious when using smartphone-interfacing mobile platforms and wearable technologies, given the lack of a current academic governing board certification and clinical practice validation processes.
Collapse
Affiliation(s)
- Neil V Shah
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY) Downstate Medical Center, 450 Clarkson Ave, MSC 30, Brooklyn, NY, 11203, USA.
| | - Richard Gold
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY) Downstate Medical Center, 450 Clarkson Ave, MSC 30, Brooklyn, NY, 11203, USA
- School of Medicine, Saint George's University, True Blue, West Indies, Grenada
| | - Qurratul-Ain Dar
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY) Downstate Medical Center, 450 Clarkson Ave, MSC 30, Brooklyn, NY, 11203, USA
| | - Bassel G Diebo
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY) Downstate Medical Center, 450 Clarkson Ave, MSC 30, Brooklyn, NY, 11203, USA
| | - Carl B Paulino
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY) Downstate Medical Center, 450 Clarkson Ave, MSC 30, Brooklyn, NY, 11203, USA
- Department of Orthopaedic Surgery, New York-Presbyterian Brooklyn Methodist Hospital, Brooklyn, NY, USA
| | - Qais Naziri
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY) Downstate Medical Center, 450 Clarkson Ave, MSC 30, Brooklyn, NY, 11203, USA
| |
Collapse
|
32
|
Cai L, Burton A, Gonzales DA, Kasper KA, Azami A, Peralta R, Johnson M, Bakall JA, Barron Villalobos E, Ross EC, Szivek JA, Margolis DS, Gutruf P. Osseosurface electronics-thin, wireless, battery-free and multimodal musculoskeletal biointerfaces. Nat Commun 2021; 12:6707. [PMID: 34795247 PMCID: PMC8602388 DOI: 10.1038/s41467-021-27003-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 10/27/2021] [Indexed: 01/23/2023] Open
Abstract
Bioelectronic interfaces have been extensively investigated in recent years and advances in technology derived from these tools, such as soft and ultrathin sensors, now offer the opportunity to interface with parts of the body that were largely unexplored due to the lack of suitable tools. The musculoskeletal system is an understudied area where these new technologies can result in advanced capabilities. Bones as a sensor and stimulation location offer tremendous advantages for chronic biointerfaces because devices can be permanently bonded and provide stable optical, electromagnetic, and mechanical impedance over the course of years. Here we introduce a new class of wireless battery-free devices, named osseosurface electronics, which feature soft mechanics, ultra-thin form factor and miniaturized multimodal biointerfaces comprised of sensors and optoelectronics directly adhered to the surface of the bone. Potential of this fully implanted device class is demonstrated via real-time recording of bone strain, millikelvin resolution thermography and delivery of optical stimulation in freely-moving small animal models. Battery-free device architecture, direct growth to the bone via surface engineered calcium phosphate ceramic particles, demonstration of operation in deep tissue in large animal models and readout with a smartphone highlight suitable characteristics for exploratory research and utility as a diagnostic and therapeutic platform.
Collapse
Affiliation(s)
- Le Cai
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Alex Burton
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - David A Gonzales
- Department of Orthopaedic Surgery and Arizona Arthritis Center, University of Arizona, Tucson, AZ, 85721, USA
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Amirhossein Azami
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Roberto Peralta
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Megan Johnson
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Jakob A Bakall
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Efren Barron Villalobos
- Department of Orthopaedic Surgery and Arizona Arthritis Center, University of Arizona, Tucson, AZ, 85721, USA
| | - Ethan C Ross
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - John A Szivek
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
- Department of Orthopaedic Surgery and Arizona Arthritis Center, University of Arizona, Tucson, AZ, 85721, USA
| | - David S Margolis
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.
- Department of Orthopaedic Surgery and Arizona Arthritis Center, University of Arizona, Tucson, AZ, 85721, USA.
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.
- Departments of Electrical and Computer Engineering, BIO5 Institute, Neuroscience GIDP, University of Arizona, Tucson, AZ, 85721, USA.
| |
Collapse
|
33
|
Loeza-Mejía CI, Sánchez-DelaCruz E, Pozos-Parra P, Landero-Hernández LA. The potential and challenges of Health 4.0 to face COVID-19 pandemic: a rapid review. HEALTH AND TECHNOLOGY 2021; 11:1321-1330. [PMID: 34603926 PMCID: PMC8477175 DOI: 10.1007/s12553-021-00598-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 09/14/2021] [Indexed: 11/05/2022]
Abstract
The COVID-19 pandemic has generated the need to evolve health services to reduce the risk of contagion and promote a collaborative environment even remotely. Advances in Industry 4.0, including the internet of things, mobile networks, cloud computing, and artificial intelligence make Health 4.0 possible to connect patients with healthcare professionals. Hence, the focus of this work is analyzing the potentiality, and challenges of state-of-the-art Health 4.0 applications to face the COVID-19 pandemic including augmented environments, diagnosis of the virus, forecasts, medical robotics, and remote clinical services. It is concluded that Health 4.0 can be applied in the prevention of contagion, improve diagnosis, promote virtual learning environments, and offer remote services. However, there are still ethical, technical, security, and legal challenges to be addressed. Additionally, more imaging datasets for COVID-19 detection need to be made available to the scientific community. Working in the areas of opportunity will help to address the new normal. Likewise, Health 4.0 can be applied not only in the COVID-19 pandemic, but also in future global viruses and natural disasters.
Collapse
|
34
|
Smart sensor implant technology in total knee arthroplasty. J Clin Orthop Trauma 2021; 22:101605. [PMID: 34631412 PMCID: PMC8479248 DOI: 10.1016/j.jcot.2021.101605] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 09/19/2021] [Accepted: 09/19/2021] [Indexed: 01/30/2023] Open
Abstract
Innovations in computer technology and implant design have paved the way for the development of smart instruments and intelligent implants in trauma and orthopaedics to improve patient-related functional outcomes. Sensor technology uses embedded devices that detect physical, chemical and biological signals and provide a way for these signals to be measured and recorded. Sensor technology applications have been introduced in various fields of medicine in the diagnosis, treatment and monitoring of diseases. Intelligent 'Smart' implants are devices that can provide diagnostic capabilities along with therapeutic benefits. In trauma and orthopaedics, applications of sensors is increasing because of the advances in microchip technologies for implant devices and research designs. It offers real-time monitoring from the signals transmitted by the embedded sensors and thus provides early management solutions. Smart orthopaedic implants have applications in total knee arthroplasty, hip arthroplasty, spine surgery, fracture healing, early detection of infection and implant loosening. Here we have explored the role of Smart sensor implant technology in total knee arthroplasty. Smart sensor assisted can be used intraoperatively to provide objective assessment of ligament and soft tissue balancing whilst maintaining the sagittal and coronal alignment to achieve desired kinematic targets following total knee arthroplasty. It can also provide post-implantation data to monitor implant performance in natural conditions and patient's clinical recovery during rehabilitation. The use of Smart Sensor implant technology in total knee arthroplasty appears to provide superior patient satisfaction rates and improved functional outcomes.
Collapse
|
35
|
Performance of a Piezoelectric Energy Harvesting System for an Energy-Autonomous Instrumented Total Hip Replacement: Experimental and Numerical Evaluation. MATERIALS 2021; 14:ma14185151. [PMID: 34576375 PMCID: PMC8470322 DOI: 10.3390/ma14185151] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 08/31/2021] [Accepted: 09/01/2021] [Indexed: 01/16/2023]
Abstract
Instrumented implants can improve the clinical outcome of total hip replacements (THRs). To overcome the drawbacks of external energy supply and batteries, energy harvesting is a promising approach to power energy-autonomous implants. Therefore, we recently presented a new piezoelectric-based energy harvesting concept for THRs. In this study, the performance of the proposed energy harvesting system was numerically and experimentally investigated. First, we numerically reproduced our previous results for the physiologically based loading situation in a simplified setup. Thereafter, this configuration was experimentally realised by the implantation of a functional model of the energy harvesting concept into an artificial bone segment. Additionally, the piezoelectric element alone was investigated to analyse the predictive power of the numerical model. We measured the generated voltage for a load profile for walking and calculated the power output. The maximum power for the directly loaded piezoelectric element and the functional model were 28.6 and 10.2 µW, respectively. Numerically, 72.7 µW was calculated. The curve progressions were qualitatively in good accordance with the numerical data. The deviations were explained by sensitivity analysis and model simplifications, e.g., material data or lower acting force levels by malalignment and differences between virtual and experimental implantation. The findings verify the feasibility of the proposed energy harvesting concept and form the basis for design optimisations with increased power output.
Collapse
|
36
|
Wang D, Tan J, Zhu H, Mei Y, Liu X. Biomedical Implants with Charge-Transfer Monitoring and Regulating Abilities. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2004393. [PMID: 34166584 PMCID: PMC8373130 DOI: 10.1002/advs.202004393] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 05/12/2021] [Indexed: 05/06/2023]
Abstract
Transmembrane charge (ion/electron) transfer is essential for maintaining cellular homeostasis and is involved in many biological processes, from protein synthesis to embryonic development in organisms. Designing implant devices that can detect or regulate cellular transmembrane charge transfer is expected to sense and modulate the behaviors of host cells and tissues. Thus, charge transfer can be regarded as a bridge connecting living systems and human-made implantable devices. This review describes the mode and mechanism of charge transfer between organisms and nonliving materials, and summarizes the strategies to endow implants with charge-transfer regulating or monitoring abilities. Furthermore, three major charge-transfer controlling systems, including wired, self-activated, and stimuli-responsive biomedical implants, as well as the design principles and pivotal materials are systematically elaborated. The clinical challenges and the prospects for future development of these implant devices are also discussed.
Collapse
Affiliation(s)
- Donghui Wang
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
- School of Materials Science and EngineeringHebei University of TechnologyTianjin300130China
| | - Ji Tan
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
| | - Hongqin Zhu
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
- Department of Materials ScienceFudan UniversityShanghai200433China
| | - Yongfeng Mei
- Department of Materials ScienceFudan UniversityShanghai200433China
| | - Xuanyong Liu
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
- School of Chemistry and Materials ScienceHangzhou Institute for Advanced StudyUniversity of Chinese Academy of SciencesHangzhou310024China
| |
Collapse
|
37
|
Lightsey HM, Yeung CM, Samartzis D, Makhni MC. The past, present, and future of remote patient monitoring in spine care: an overview. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2021; 30:2102-2108. [PMID: 34241698 DOI: 10.1007/s00586-021-06921-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2020] [Revised: 04/25/2021] [Accepted: 07/05/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE Remote patient monitoring (RPM) has revolutionized the landscape of healthcare. From humble beginnings rooted in landline home telephone calls to present-day devices with near instantaneous wireless connectivity, the evolution of technology has ushered in an era of digital medicine and remote care. Presently, a vast array of healthcare data points can be automatically generated, analyzed, and forwarded to providers to supplement clinical decision-making. While RPM originated and was popularized within medicine, its role in orthopedics, and particularly within spine surgery, is evolving. We sought to provide an overview of RPM within orthopedics, with specific attention on spine care, analyzing its origins, present-day form, and prospects. METHODS We reviewed the literature to date as it pertains to RPM within healthcare at large, orthopedics, and spine care. RESULTS We detail the development and clinical use of wearable technology and smart implants, examining the underlying technology and evaluating the spectrum of their present-day and potential applications. CONCLUSIONS Technological advancements are not only reshaping the paradigm of musculoskeletal care but are also redefining the physician-patient relationship as well as reimagining traditional perspectives on healthcare data collection and privacy.
Collapse
Affiliation(s)
- Harry M Lightsey
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Caleb M Yeung
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Dino Samartzis
- Department of Orthopaedic Surgery, Rush Medical College, Chicago, IL, USA
| | - Melvin C Makhni
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA.
| |
Collapse
|
38
|
Ernst M, Richards RG, Windolf M. Smart implants in fracture care - only buzzword or real opportunity? Injury 2021; 52 Suppl 2:S101-S105. [PMID: 32980139 DOI: 10.1016/j.injury.2020.09.026] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 09/07/2020] [Accepted: 09/15/2020] [Indexed: 02/02/2023]
Abstract
The assessment of fracture healing is still marked by a subjective and diffuse outcome due to the lack of clinically available quantitative measures. Without reliable information on the progression of healing and uniform criteria for union and non-union, therapeutic decision making, e.g. regarding the allowed weight bearing, hinges on the experience and the subjective evaluation of physicians. Already decades ago, fracture stiffness has been identified as a valid outcome measure for the maturity of the repair tissue. Despite early promising results, so far no method has made its way into practice beyond clinical studies. However, with current technological advancements and a general trend towards digital health care, measuring fracture healing seems to regain momentum. New generations of instrumented implants with sensoring capabilities, often termed as "smart implants", are under development. They target X-ray free and timely provision of reliable feedback upon the mechanical competence of the repair tissue and the healing environment to support therapeutic decision making and individualized after-care. With the gained experience from these devices, the next generations of smart implants may become increasingly sophisticated by internally analyzing the measured data and suggesting adequate therapeutic actions on their own.
Collapse
Affiliation(s)
- Manuela Ernst
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos Platz, Switzerland.
| | - R Geoff Richards
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos Platz, Switzerland.
| | - Markus Windolf
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos Platz, Switzerland.
| |
Collapse
|
39
|
Losic D. Advancing of titanium medical implants by surface engineering: recent progress and challenges. Expert Opin Drug Deliv 2021; 18:1355-1378. [PMID: 33985402 DOI: 10.1080/17425247.2021.1928071] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Introduction:Titanium (Ti) and their alloys are used as main implant materials in orthopedics and dentistry for decades having superior mechanical properties, chemical stability and biocompatibility. Their rejections due lack of biointegration and bacterial infection are concerning with considerable healthcare costs and impacts on patients. To address these limitations, conventional Ti implants need improvements where the use of surface nanoengineering approaches and the development of a new generation of implants are recognized as promising strategies.Areas covered:This review presents an overview of recent progress on the application of surface engineering methods to advance Ti implants enable to address their key limitations. Several promising surface engineering strategies are presented and critically discussed to generate advanced surface properties and nano-topographies (tubular, porous, pillars) able not only to improve their biointegration, antibacterial performances, but also to provide multiple functions such as drug delivery, therapy, sensing, communication and health monitoring underpinning the development of new generation and smart medical implants.Expert opinion:Recent advances in cell biology, materials science, nanotechnology and additive manufacturing has progressively influencing improvements of conventional Ti implants toward the development of the next generation of implants with improved performances and multifunctionality. Current research and development are in early stage, but progressing with promising results and examples of moving into in-vivo studies an translation into real applications.
Collapse
Affiliation(s)
- Dusan Losic
- School of Chemical Engineering and Advanced Materials, The University of Adelaide, Engineering North Building, Adelaide, SA, Australia.,ARC Research Hub for Graphene Enabled Industry Transformation, The University of Adelaide, Engineering North Building, Adelaide, SA, Australia
| |
Collapse
|
40
|
Pawelec KM, Chakravarty S, Hix JML, Perry KL, van Holsbeeck L, Fajardo R, Shapiro EM. Design Considerations to Facilitate Clinical Radiological Evaluation of Implantable Biomedical Structures. ACS Biomater Sci Eng 2021; 7:718-726. [PMID: 33449622 PMCID: PMC8670580 DOI: 10.1021/acsbiomaterials.0c01439] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Clinical effectiveness of implantable medical devices would be improved with in situ monitoring to ensure device positioning, determine subsequent damage, measure biodegradation, and follow healing. While standard clinical imaging protocols are appropriate for diagnosing disease and injury, these protocols have not been vetted for imaging devices. This study investigated how radiologists use clinical imaging to detect the location and integrity of implanted devices and whether embedding nanoparticle contrast agents into devices can improve assessment. To mimic the variety of devices available, phantoms from hydrophobic polymer films and hydrophilic gels were constructed, with and without computed tomography (CT)-visible TaOx and magnetic resonance imaging (MRI)-visible Fe3O4 nanoparticles. Some phantoms were purposely damaged by nick or transection. Phantoms were implanted in vitro into tissue and imaged with clinical CT, MRI, and ultrasound. In a blinded study, radiologists independently evaluated whether phantoms were present, assessed the type, and diagnosed whether phantoms were damaged or intact. Radiologists identified the location of phantoms 80% of the time. However, without incorporated nanoparticles, radiologists correctly assessed damage in only 54% of cases. With an incorporated imaging agent, the percentage jumped to 86%. The imaging technique which was most useful to radiologists varied with the properties of phantoms. With benefits and drawbacks to all three imaging modalities, future implanted devices should be engineered for visibility in the modality which best fits the treated tissue, the implanted device's physical location, and the type of required information. Imaging protocols should also be tailored to best exploit the properties of the imaging agents.
Collapse
Affiliation(s)
- Kendell M Pawelec
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Shatadru Chakravarty
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Jeremy M L Hix
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Karen L Perry
- College of Veterinary Medicine, Michigan State University, East Lansing, Michigan 48824, United States
| | - Lodewijk van Holsbeeck
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Ryan Fajardo
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Erik M Shapiro
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| |
Collapse
|
41
|
Hall TAG, Cegla F, van Arkel RJ. Simple Smart Implants: Simultaneous Monitoring of Loosening and Temperature in Orthopaedics With an Embedded Ultrasound Transducer. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:102-110. [PMID: 33471767 DOI: 10.1109/tbcas.2021.3052970] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Implant failure can have devastating consequences on patient outcomes following joint replacement. Time to diagnosis affects subsequent treatment success, but current diagnostics do not give early warning and lack accuracy. This research proposes an embedded ultrasound system to monitor implant fixation and temperature - a potential indicator of infection. Requiring only two implanted components: a piezoelectric transducer and a coil, pulse-echo responses are elicited via a three-coil inductive link. This passive system avoids the need for batteries, energy harvesters, and microprocessors, resulting in minimal changes to existing implant architecture. Proof-of-concept was demonstrated in vitro for a titanium plate cemented into synthetic bone, using a small embedded coil with 10 mm diameter. Gross loosening - simulated by completely debonding the implant-cement interface - was detectable with 95% confidence at up to 12 mm implantation depth. Temperature was calibrated with root mean square error of 0.19°C at 5 mm, with measurements accurate to ±1°C with 95% confidence up to 6 mm implantation depth. These data demonstrate that with only a transducer and coil implanted, it is possible to measure fixation and temperature simultaneously. This simple smart implant approach minimises the need to modify well-established implant designs, and hence could enable mass-market adoption.
Collapse
|
42
|
Sarraf M, Nasiri-Tabrizi B, Yeong CH, Madaah Hosseini HR, Saber-Samandari S, Basirun WJ, Tsuzuki T. Mixed oxide nanotubes in nanomedicine: A dead-end or a bridge to the future? CERAMICS INTERNATIONAL 2021; 47:2917-2948. [PMID: 32994658 PMCID: PMC7513735 DOI: 10.1016/j.ceramint.2020.09.177] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 09/16/2020] [Accepted: 09/18/2020] [Indexed: 05/12/2023]
Abstract
Nanomedicine has seen a significant rise in the development of new research tools and clinically functional devices. In this regard, significant advances and new commercial applications are expected in the pharmaceutical and orthopedic industries. For advanced orthopedic implant technologies, appropriate nanoscale surface modifications are highly effective strategies and are widely studied in the literature for improving implant performance. It is well-established that implants with nanotubular surfaces show a drastic improvement in new bone creation and gene expression compared to implants without nanotopography. Nevertheless, the scientific and clinical understanding of mixed oxide nanotubes (MONs) and their potential applications, especially in biomedical applications are still in the early stages of development. This review aims to establish a credible platform for the current and future roles of MONs in nanomedicine, particularly in advanced orthopedic implants. We first introduce the concept of MONs and then discuss the preparation strategies. This is followed by a review of the recent advancement of MONs in biomedical applications, including mineralization abilities, biocompatibility, antibacterial activity, cell culture, and animal testing, as well as clinical possibilities. To conclude, we propose that the combination of nanotubular surface modification with incorporating sensor allows clinicians to precisely record patient data as a critical contributor to evidence-based medicine.
Collapse
Key Words
- ALP, Alkaline Phosphatase
- APH, Anodization-Cyclic Precalcification-Heat Treatment
- Ag2O NPs, Silver Oxide Nanoparticles
- AgNPs, Silver Nanoparticles
- Anodization
- BIC, Bone-Implant Contact
- Bioassays
- CAGR, Compound Annual Growth Rate
- CT, Computed Tomography
- DMF, Dimethylformamide
- DMSO, Dimethyl Sulfoxide
- DRI, Drug-Releasing Implants
- E. Coli, Escherichia Coli
- ECs, Endothelial Cells
- EG, Ethylene Glycol
- Electrochemistry
- FA, Formamide
- Fe2+, Ferrous Ion
- Fe3+, Ferric Ion
- Fe3O4, Magnetite
- GEP, Gene Expression Programming
- GO, Graphene Oxide
- HA, Hydroxyapatite
- HObs, Human Osteoblasts
- HfO2 NTs, Hafnium Oxide Nanotubes
- IMCs, Intermetallic Compounds
- LEDs, Light emitting diodes
- MEMS, Microelectromechanical Systems
- MONs, Mixed Oxide Nanotubes
- MOPSO, Multi-Objective Particle Swarm Optimization
- MSCs, Mesenchymal Stem Cells
- Mixed oxide nanotubes
- NMF, N-methylformamide
- Nanomedicine
- OPC1, Osteo-Precursor Cell Line
- PSIs, Patient-Specific Implants
- PVD, Physical Vapor Deposition
- RF, Radio-Frequency
- ROS, Radical Oxygen Species
- S. aureus, Staphylococcus Aureus
- S. epidermidis, Staphylococcus Epidermidis
- SBF, Simulated Body Fluid
- TiO2 NTs, Titanium Dioxide Nanotubes
- V2O5, Vanadium Pentoxide
- VSMCs, Vascular Smooth Muscle Cells
- XPS, X-ray Photoelectron Spectroscopy
- ZrO2 NTs, Zirconium Dioxide Nanotubes
- hASCs, Human Adipose-Derived Stem Cells
Collapse
Affiliation(s)
- Masoud Sarraf
- Centre of Advanced Materials, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Materials Science and Engineering Department, Sharif University of Technology, P.O. Box 11155-9466, Azadi Avenue, Tehran, Iran
| | - Bahman Nasiri-Tabrizi
- School of Biosciences, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya, Malaysia
- New Technologies Research Center, Amirkabir University of Technology, Tehran, Iran
| | - Chai Hong Yeong
- School of Medicine, Faculty of Health and Medical Sciences, Taylor's University, Subang Jaya, Malaysia
| | - Hamid Reza Madaah Hosseini
- Materials Science and Engineering Department, Sharif University of Technology, P.O. Box 11155-9466, Azadi Avenue, Tehran, Iran
| | | | - Wan Jefrey Basirun
- Department of Chemistry, Faculty of Science, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Takuya Tsuzuki
- Research School of Electrical Energy and Materials Engineering, College of Engineering and Computer Science, Australian National University, Canberra, 2601, Australia
| |
Collapse
|
43
|
Baumann AP, O'Neill C, Owens MC, Weber SC, Sivan S, D'Amico R, Carmody S, Bini S, Sawyer AJ, Lotz JC, Goel V, Dmitriev AE. FDA public workshop: Orthopaedic sensing, measuring, and advanced reporting technology (SMART) devices. J Orthop Res 2021; 39:22-29. [PMID: 32827329 DOI: 10.1002/jor.24833] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 08/10/2020] [Accepted: 08/18/2020] [Indexed: 02/04/2023]
Abstract
Traditional orthopaedic devices do not communicate with physicians or patients post-operatively. After implantation, follow-up of traditional orthopaedic devices is generally limited to episodic monitoring. However, the orthopaedic community may be shifting towards incorporation of smart technology. Smart technology in orthopaedics is a term that encompasses a wide range of potential applications. Smart orthopaedic implants offer the possibility of gathering data and exchanging it with an external reader. They incorporate technology that enables automated sensing, measuring, processing, and reporting of patient or device parameters at or near the implant. While including advanced technology in orthopaedic devices has the potential to benefit patients, physicians, and the scientific community, it may also increase the patient risks associated with the implants. Understanding the benefit-risk profile of new smart orthopaedic devices is critical to ensuring their safety and effectiveness. The 2018 FDA public workshop on orthopaedic sensing, measuring, and advanced reporting technology (SMART) devices was held on April 30, 2018, at the FDA White Oak Campus in Silver Spring, MD with the goal of fostering a collaborative dialogue amongst the orthopaedic community. Workshop attendees discussed four key areas related to smart orthopaedic devices: engineering and technology considerations, clinical and patient perspectives, cybersecurity, and regulatory considerations. The workshop presentations and associated discussions highlighted the need for the orthopaedic community to collectively craft a responsible path for incorporating smart technology in musculoskeletal disease care.
Collapse
Affiliation(s)
- Andrew P Baumann
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| | - Colin O'Neill
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| | - Michael C Owens
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| | - Stephen C Weber
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| | - Shiril Sivan
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| | - Reid D'Amico
- American Institute of Medical and Biological Engineering (AIMBE) Scholar, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| | - Seth Carmody
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| | - Stefano Bini
- Department of Orthopaedic Surgery, University of California, San Francisco (UCSF), San Francisco, California
| | - Aenor J Sawyer
- Department of Orthopaedic Surgery, University of California, San Francisco (UCSF), San Francisco, California
| | - Jeffrey C Lotz
- Department of Orthopaedic Surgery, University of California, San Francisco (UCSF), San Francisco, California
| | - Vijay Goel
- Departments of Bioengineering and Orthopaedic Surgery, Colleges of Engineering and Medicine, University of Toledo, Toledo, Ohio
| | - Anton E Dmitriev
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland
| |
Collapse
|
44
|
Palmroth A, Salpavaara T, Vuoristo P, Karjalainen S, Kääriäinen T, Miettinen S, Massera J, Lekkala J, Kellomäki M. Materials and Orthopedic Applications for Bioresorbable Inductively Coupled Resonance Sensors. ACS APPLIED MATERIALS & INTERFACES 2020; 12:31148-31161. [PMID: 32568505 PMCID: PMC7467565 DOI: 10.1021/acsami.0c07278] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Accepted: 06/22/2020] [Indexed: 06/11/2023]
Abstract
Bioresorbable passive resonance sensors based on inductor-capacitor (LC) circuits provide an auspicious sensing technology for temporary battery-free implant applications due to their simplicity, wireless readout, and the ability to be eventually metabolized by the body. In this study, the fabrication and performance of various LC circuit-based sensors are investigated to provide a comprehensive view on different material options and fabrication methods. The study is divided into sections that address different sensor constituents, including bioresorbable polymer and bioactive glass substrates, dissolvable metallic conductors, and atomic layer deposited (ALD) water barrier films on polymeric substrates. The manufactured devices included a polymer-based pressure sensor that remained pressure responsive for 10 days in aqueous conditions, the first wirelessly readable bioactive glass-based resonance sensor for monitoring the complex permittivity of its surroundings, and a solenoidal coil-based compression sensor built onto a polymeric bone fixation screw. The findings together with the envisioned orthopedic applications provide a reference point for future studies related to bioresorbable passive resonance sensors.
Collapse
Affiliation(s)
- Aleksi Palmroth
- BioMediTech,
Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
| | - Timo Salpavaara
- BioMediTech,
Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
| | - Petri Vuoristo
- Materials
Science and Environmental Engineering, Faculty of Engineering and
Natural Sciences, Tampere University, Korkeakoulunkatu 6, Tampere 33720, Finland
| | - Sanna Karjalainen
- BioMediTech,
Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
| | - Tommi Kääriäinen
- Department
of Chemistry, University of Colorado Boulder, Boulder, Colorado 80309, United States
| | - Susanna Miettinen
- BioMediTech,
Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
| | - Jonathan Massera
- BioMediTech,
Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
| | - Jukka Lekkala
- BioMediTech,
Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
| | - Minna Kellomäki
- BioMediTech,
Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 3, Tampere 33720, Finland
| |
Collapse
|
45
|
Suckey MM, Benza D, Arifuzzaman M, Millhouse PW, Anderson D, Heath J, DesJardins JD, Anker JN. Luminescent Spectral Rulers for Noninvasive Displacement Measurement through Tissue. ACS Sens 2020; 5:711-718. [PMID: 32096404 DOI: 10.1021/acssensors.9b01930] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
A luminescent spectral ruler was developed to measure micrometer to millimeter displacements through tissue. The spectral ruler has two components: a luminescent encoder patterned with alternating stripes of two spectrally distinct luminescent materials and an analyzer mask with periodic transparent windows the same width as the encoder stripes. The analyzer mask is placed over the encoder and held so that only one type of luminescent stripe is visible through the window; sliding the analyzer over the encoder modulates the luminescence spectrum acquired through the analyzer windows, enabling detection of small displacements without imaging. We prepared two types of spectral rulers, one with a fluorescent encoder and a second with an X-ray excited optical luminescent (XEOL) encoder. The fluorescent ruler used two types of quantum dots to form stripes that were excited with 633 nm light and emitted at 645 and 680 nm, respectively. Each ruler type was covered with chicken breast tissue to simulate implantation. The XEOL ruler generated a strong signal with negligible tissue autofluorescence but used ionizing radiation, while the fluorescence ruler used non-ionizing red light excitation but required spectral fitting to account for tissue autofluorescence. The precision for both types of luminescent spectral rulers (with 1 mm wide analyzer windows, and measured through 6 mm of tissue) was <2 μm, mostly limited by shot noise. The approach enabled high micrometer to millimeter displacement measurements through tissue and has applications in biomechanical and mechanochemical measurements (e.g., tracking postsurgical bone healing and implant-associated infection).
Collapse
Affiliation(s)
- Melissa M. Suckey
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| | - Donald Benza
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
- Department of Electrical and Computer Engineering, Clemson University, Clemson, South Carolina 29634, United States
| | - Md. Arifuzzaman
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| | - Paul W. Millhouse
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| | - Dakotah Anderson
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| | - Jonathan Heath
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| | - John D. DesJardins
- Department of BioEngineering, Clemson University, Clemson, South Carolina 29634, United States
| | - Jeffrey N. Anker
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
- Center for Optical Materials Science and Engineering Technology (COMSET) and Environmental Toxicology Program, Clemson University, Clemson, South Carolina 29634, United States
- Department of BioEngineering, Clemson University, Clemson, South Carolina 29634, United States
| |
Collapse
|
46
|
Schmal H, Brix M, Bue M, Ekman A, Ferreira N, Gottlieb H, Kold S, Taylor A, Toft Tengberg P, Ban I. Nonunion - consensus from the 4th annual meeting of the Danish Orthopaedic Trauma Society. EFORT Open Rev 2020; 5:46-57. [PMID: 32071773 PMCID: PMC7017598 DOI: 10.1302/2058-5241.5.190037] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Nonunions are a relevant economic burden affecting about 1.9% of all fractures. Rather than specifying a certain time frame, a nonunion is better defined as a fracture that will not heal without further intervention. Successful fracture healing depends on local biology, biomechanics and a variety of systemic factors. All components can principally be decisive and determine the classification of atrophic, oligotrophic or hypertrophic nonunions. Treatment prioritizes mechanics before biology. The degree of motion between fracture parts is the key for healing and is described by strain theory. If the change of length at a given load is > 10%, fibrous tissue and not bone is formed. Therefore, simple fractures require absolute and complex fractures relative stability. The main characteristics of a nonunion are pain while weight bearing, and persistent fracture lines on X-ray. Treatment concepts such as ‘mechanobiology’ or the ‘diamond concept’ determine the applied osteosynthesis considering soft tissue, local biology and stability. Fine wire circular external fixation is considered the only form of true biologic fixation due to its ability to eliminate parasitic motions while maintaining load-dependent axial stiffness. Nailing provides intramedullary stability and biology via reaming. Plates are successful when complex fractures turn into simple nonunions demanding absolute stability. Despite available alternatives, autograft is the gold standard for providing osteoinductive and osteoconductive stimuli. The infected nonunion remains a challenge. Bacteria, especially staphylococcus species, have developed mechanisms to survive such as biofilm formation, inactive forms and internalization. Therefore, radical debridement and specific antibiotics are necessary prior to reconstruction.
Cite this article: EFORT Open Rev 2020;5:46-57. DOI: 10.1302/2058-5241.5.190037
Collapse
Affiliation(s)
- Hagen Schmal
- Department of Orthopaedics and Traumatology, Odense University Hospital, Odense, Denmark.,Department of Orthopaedics and Traumatology, Freiburg University Hospital, Freiburg, Germany
| | - Michael Brix
- Department of Orthopaedics and Traumatology, Odense University Hospital, Odense, Denmark
| | - Mats Bue
- Department of Orthopaedic Surgery, Horsens Regional Hospital, Horsens, Denmark
| | - Anna Ekman
- Orthopaedic Department, Södersjukhuset, Stockholm, Sweden
| | - Nando Ferreira
- Division of Orthopaedics, Faculty of Medicine and Health Sciences, Stellenbosch University, Tygerberg Hospital, Cape Town, South Africa
| | - Hans Gottlieb
- Department of Orthopaedic Surgery, Herlev Hospital, Herlev, Denmark
| | - Søren Kold
- Department of Orthopaedic Surgery, Aalborg University Hospital, Aalborg University, Aalborg, Denmark
| | - Andrew Taylor
- Department of Orthopaedic Surgery, Nottingham University Hospitals, UK
| | - Peter Toft Tengberg
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark
| | - Ilija Ban
- Department of Orthopaedic Surgery, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark
| | | |
Collapse
|
47
|
Kim T, See CW, Li X, Zhu D. Orthopedic implants and devices for bone fractures and defects: Past, present and perspective. ENGINEERED REGENERATION 2020. [DOI: 10.1016/j.engreg.2020.05.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
48
|
Cachão JH, Soares dos Santos MP, Bernardo R, Ramos A, Bader R, Ferreira JAF, Torres Marques A, Simões JAO. Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants. SENSORS 2019; 20:s20010104. [PMID: 31878028 PMCID: PMC6982938 DOI: 10.3390/s20010104] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 11/07/2019] [Accepted: 11/10/2019] [Indexed: 02/02/2023]
Abstract
Musculoskeletal disorders are becoming an ever-growing societal burden and, as a result, millions of bone replacements surgeries are performed per year worldwide. Despite total joint replacements being recognized among the most successful surgeries of the last century, implant failure rates exceeding 10% are still reported. These numbers highlight the necessity of technologies to provide an accurate monitoring of the bone–implant interface state. This study provides a detailed review of the most relevant methodologies and technologies already proposed to monitor the loosening states of endoprosthetic implants, as well as their performance and experimental validation. A total of forty-two papers describing both intracorporeal and extracorporeal technologies for cemented or cementless fixation were thoroughly analyzed. Thirty-eight technologies were identified, which are categorized into five methodologies: vibrometric, acoustic, bioelectric impedance, magnetic induction, and strain. Research efforts were mainly focused on vibrometric and acoustic technologies. Differently, approaches based on bioelectric impedance, magnetic induction and strain have been less explored. Although most technologies are noninvasive and are able to monitor different loosening stages of endoprosthetic implants, they are not able to provide effective monitoring during daily living of patients.
Collapse
Affiliation(s)
- João Henrique Cachão
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Marco P. Soares dos Santos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
- Associated Laboratory for Energy, Transports and Aeronautics (LAETA), 4150-179 Porto, Portugal
- Correspondence:
| | - Rodrigo Bernardo
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Ramos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| | - Rainer Bader
- Department of Orthopedics, University Medicine Rostock, 18057 Rostock, Germany
| | - Jorge A. F. Ferreira
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Torres Marques
- Associated Laboratory for Energy, Transports and Aeronautics (LAETA), 4150-179 Porto, Portugal
- Mechanical Engineering Department, University of Porto, 4200-465 Porto, Portugal
| | - José A. O. Simões
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
- Center for Mechanical Technology & Automation (TEMA), University of Aveiro, 3810-193 Aveiro, Portugal
| |
Collapse
|
49
|
Garino JP. CORR Insights®: Partially Melted Ti6Al4V Particles Increase Bacterial Adhesion and Inhibit Osteogenic Activity on 3D-printed Implants: An In Vitro Study. Clin Orthop Relat Res 2019; 477:2783. [PMID: 31764351 PMCID: PMC6907298 DOI: 10.1097/corr.0000000000001020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2019] [Accepted: 10/09/2019] [Indexed: 01/31/2023]
Affiliation(s)
- Jonathan P Garino
- J. P. Garino, Clinical Professor, Pennsylvania Orthopedic Center, Department of Orthopedic Surgery, Malvern, PA, USA
| |
Collapse
|