1
|
Qiu L, Jiang H, Cho K, Yu Y, Jones LA, Huang T, Perlmutter JS, Gropler RJ, Brier MR, Patti GJ, Benzinger TLS, Tu Z. Metabolite Study and Structural Authentication for the First-in-Human Use Sphingosine-1-phosphate Receptor 1 Radiotracer. ACS Chem Neurosci 2024; 15:1882-1892. [PMID: 38634759 PMCID: PMC11103254 DOI: 10.1021/acschemneuro.4c00077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2024] Open
Abstract
The sphingosine-1-phosphate receptor 1 (S1PR1) radiotracer [11C]CS1P1 has shown promise in proof-of-concept PET imaging of neuroinflammation in multiple sclerosis (MS). Our HPLC radiometabolite analysis of human plasma samples collected during PET scans with [11C]CS1P1 detected a radiometabolite peak that is more lipophilic than [11C]CS1P1. Radiolabeled metabolites that cross the blood-brain barrier complicate quantitative modeling of neuroimaging tracers; thus, characterizing such radiometabolites is important. Here, we report our detailed investigation of the metabolite profile of [11C]CS1P1 in rats, nonhuman primates, and humans. CS1P1 is a fluorine-containing ligand that we labeled with C-11 or F-18 for preclinical studies; the brain uptake was similar for both radiotracers. The same lipophilic radiometabolite found in human studies also was observed in plasma samples of rats and NHPs for CS1P1 labeled with either C-11 or F-18. We characterized the metabolite in detail using rats after injection of the nonradioactive CS1P1. To authenticate the molecular structure of this radiometabolite, we injected rats with 8 mg/kg of CS1P1 to collect plasma for solvent extraction and HPLC injection, followed by LC/MS analysis of the same metabolite. The LC/MS data indicated in vivo mono-oxidation of CS1P1 produces the metabolite. Subsequently, we synthesized three different mono-oxidized derivatives of CS1P1 for further investigation. Comparing the retention times of the mono-oxidized derivatives with the metabolite observed in rats injected with CS1P1 identified the metabolite as N-oxide 1, also named TZ82121. The MS fragmentation pattern of N-oxide 1 also matched that of the major metabolite in rat plasma. To confirm that metabolite TZ82121 does not enter the brain, we radiosynthesized [18F]TZ82121 by the oxidation of [18F]FS1P1. Radio-HPLC analysis confirmed that [18F]TZ82121 matched the radiometabolite observed in rat plasma post injection of [18F]FS1P1. Furthermore, the acute biodistribution study in SD rats and PET brain imaging in a nonhuman primate showed that [18F]TZ82121 does not enter the rat or nonhuman primate brain. Consequently, we concluded that the major lipophilic radiometabolite N-oxide [11C]TZ82121, detected in human plasma post injection of [11C]CS1P1, does not enter the brain to confound quantitative PET data analysis. [11C]CS1P1 is a promising S1PR1 radiotracer for detecting S1PR1 expression in the CNS.
Collapse
Affiliation(s)
- Lin Qiu
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Hao Jiang
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Kevin Cho
- Center for Mass Spectrometry and Metabolic Tracing, Department of Chemistry, Department of Medicine, Washington University, Saint Louis, Missouri 63130, United States
| | - Yanbo Yu
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Lynne A Jones
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Tianyu Huang
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Joel S Perlmutter
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
- Departments of Neurology, Neuroscience, Physical Therapy and Occupational Therapy, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Robert J Gropler
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Matthew R Brier
- Departments of Neurology, Neuroscience, Physical Therapy and Occupational Therapy, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Gary J Patti
- Center for Mass Spectrometry and Metabolic Tracing, Department of Chemistry, Department of Medicine, Washington University, Saint Louis, Missouri 63130, United States
| | - Tammie L S Benzinger
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| | - Zhude Tu
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri 63110, United States
| |
Collapse
|
2
|
Akbari B, Huber BR, Sherman JH. Unlocking the Hidden Depths: Multi-Modal Integration of Imaging Mass Spectrometry-Based and Molecular Imaging Techniques. Crit Rev Anal Chem 2023:1-30. [PMID: 37847593 DOI: 10.1080/10408347.2023.2266838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2023]
Abstract
Multimodal imaging (MMI) has emerged as a powerful tool in clinical research, combining different imaging modes to acquire comprehensive information and enabling scientists and surgeons to study tissue identification, localization, metabolic activity, and molecular discovery, thus aiding in disease progression analysis. While multimodal instruments are gaining popularity, challenges such as non-standardized characteristics, custom software, inadequate commercial support, and integration issues with other instruments need to be addressed. The field of multimodal imaging or multiplexed imaging allows for simultaneous signal reproduction from multiple imaging strategies. Intraoperatively, MMI can be integrated into frameless stereotactic surgery. Recent developments in medical imaging modalities such as magnetic resonance imaging (MRI), and Positron Emission Topography (PET) have brought new perspectives to multimodal imaging, enabling early cancer detection, molecular tracking, and real-time progression monitoring. Despite the evidence supporting the role of MMI in surgical decision-making, there is a need for comprehensive studies to validate and perform integration at the intersection of multiple imaging technologies. They were integrating mass spectrometry-based technologies (e.g., imaging mass spectrometry (IMS), imaging mass cytometry (IMC), and Ion mobility mass spectrometry ((IM-IM) with medical imaging modalities, offering promising avenues for molecular discovery and clinical applications. This review emphasizes the potential of multi-omics approaches in tissue mapping using MMI integrated into desorption electrospray ionization (DESI) and matrix-assisted laser desorption ionization (MALDI), allowing for sequential analyses of the same section. By addressing existing knowledge gaps, this review encourages future research endeavors toward multi-omics approaches, providing a roadmap for future research and enhancing the value of MMI in molecular pathology for diagnosis.
Collapse
Affiliation(s)
- Behnaz Akbari
- Department of Chemistry, Purdue University, West Lafayette, Indiana, USA
| | - Bertrand Russell Huber
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
- Boston University Alzheimer's Disease and CTE Center, Boston University School of Medicine, Boston, Massachusetts, USA
- Department of Neurology, Boston University School of Medicine, Boston, Massachusetts, USA
- US Department of Veteran Affairs, VA Boston Healthcare System, Boston, Massachusetts USA
- US Department of Veterans Affairs, National Center for PTSD, Boston, Massachusetts USA
| | - Janet Hope Sherman
- Chobanian and Avedisian School of Medicine, Boston University, Boston, Massachusetts, USA
| |
Collapse
|
3
|
Collier TL, Dahl K, Stephenson NA, Holland JP, Riley A, Liang SH, Vasdev N. Recent applications of a single quadrupole mass spectrometer in 11C, 18F and radiometal chemistry. J Fluor Chem 2018; 210:46-55. [PMID: 30410189 PMCID: PMC6217822 DOI: 10.1016/j.jfluchem.2018.02.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Mass spectrometry (MS) has longstanding applications in radiochemistry laboratories, stemming from carbon-dating. However, research on the development of radiotracers for molecular imaging with either positron emission tomography (PET) or single photon emission computed tomography has yet to take full advantage of MS. This inertia has been attributed to the relatively low concentrations of radiopharmaceutical formulations and lack of access to the required MS equipment due to the high costs for purchase and maintenance of specialized MS systems. To date, single quadrupole (SQ)-MS coupled to liquid chromatography (LC) systems is the main form of MS that has been used in radiochemistry laboratories. These LC/MS systems are primarily used for assessing the chemical purity of radiolabeling precursor or standard molecules but also have applications in the determination of metabolites. Herein, we highlight personal experiences using a compact SQ-MS in our PET radiochemistry laboratories, to monitor the small amounts of carrier observed in most radiotracer preparations, even at high molar activities. The use of a SQ-MS in the observation of the low mass associated with non-radioactive species which are formed along with the radiotracer from the trace amounts of carrier found is demonstrated. Herein, we describe a pre-concentration system to detect dilute radiopharmaceutical formulations and metabolite analyses by SQ-MS. Selected examples where SQ-MS was critical for optimization of radiochemical reactions and for unequivocal characterization of radiotracers are showcased. We also illustrate examples where SQ-MS can be applied in identification of radiometal complexes and development of a new purification methodology for Pd-catalyzed radiofluorination reactions, shedding light on the identity of metal complexes present in the labelling solution.
Collapse
Affiliation(s)
- Thomas L. Collier
- Division of Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital (MGH) & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Advion, Inc., Ithaca, New York, USA
| | - Kenneth Dahl
- Division of Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital (MGH) & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Nickeisha A. Stephenson
- Division of Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital (MGH) & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Jason P. Holland
- Division of Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital (MGH) & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Adam Riley
- Division of Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital (MGH) & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Steven H. Liang
- Division of Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital (MGH) & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Neil Vasdev
- Division of Nuclear Medicine and Molecular Imaging, Massachusetts General Hospital (MGH) & Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
4
|
Exploring the Metabolism of (+)-[ 18F]Flubatine in Vitro and in Vivo: LC-MS/MS Aided Identification of Radiometabolites in a Clinical PET Study. Molecules 2018; 23:molecules23020464. [PMID: 29461507 PMCID: PMC6017759 DOI: 10.3390/molecules23020464] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 02/15/2018] [Accepted: 02/16/2018] [Indexed: 01/25/2023] Open
Abstract
Both (+)-[18F]flubatine and its enantiomer (−)-[18F]flubatine are radioligands for the neuroimaging of α4β2 nicotinic acetylcholine receptors (nAChRs) by positron emission tomography (PET). In a clinical study in patients with early Alzheimer’s disease, (+)-[18F]flubatine ((+)-[18F]1) was examined regarding its metabolic fate, in particular by identification of degradation products detected in plasma and urine. The investigations included an in vivo study of (+)-flubatine ((+)-1) in pigs and structural elucidation of formed metabolites by LC-MS/MS. Incubations of (+)-1 and (+)-[18F]1 with human liver microsomes were performed to generate in vitro metabolites, as well as radiometabolites, which enabled an assignment of their structures by comparison of LC-MS/MS and radio-HPLC data. Plasma and urine samples taken after administration of (+)-[18F]1 in humans were examined by radio-HPLC and, on the basis of results obtained in vitro and in vivo, formed radiometabolites were identified. In pigs, (+)-1 was monohydroxylated at different sites of the azabicyclic ring system of the molecule. Additionally, one intermediate metabolite underwent glucuronidation, as also demonstrated in vitro. In humans, a fraction of 95.9 ± 1.9% (n = 10) of unchanged tracer remained in plasma, 30 min after injection. However, despite the low metabolic degradation, both radiometabolites formed in humans could be characterized as (i) a product of C-hydroxylation at the azabicyclic ring system, and (ii) a glucuronide conjugate of the precedingly-formed N8-hydroxylated (+)-[18F]1.
Collapse
|
5
|
Development of fluorine-18 labeled peptidic PET tracers for imaging active tissue transglutaminase. Nucl Med Biol 2017; 44:90-104. [DOI: 10.1016/j.nucmedbio.2016.10.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 09/22/2016] [Accepted: 10/06/2016] [Indexed: 01/30/2023]
|
6
|
LC-MS Supported Studies on the in Vitro Metabolism of both Enantiomers of Flubatine and the in Vivo Metabolism of (+)-[(18)F]Flubatine-A Positron Emission Tomography Radioligand for Imaging α4β2 Nicotinic Acetylcholine Receptors. Molecules 2016; 21:molecules21091200. [PMID: 27617996 PMCID: PMC6273452 DOI: 10.3390/molecules21091200] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 09/01/2016] [Accepted: 09/02/2016] [Indexed: 12/27/2022] Open
Abstract
Both enantiomers of [18F]flubatine are promising radioligands for neuroimaging of α4β2 nicotinic acetylcholine receptors (nAChRs) by positron emission tomography (PET). To support clinical studies in patients with early Alzheimer’s disease, a detailed examination of the metabolism in vitro and in vivo has been performed. (+)- and (−)-flubatine, respectively, were incubated with liver microsomes from mouse and human in the presence of NADPH (β-nicotinamide adenine dinucleotide 2′-phosphate reduced tetrasodium salt). Phase I in vitro metabolites were detected and their structures elucidated by LC-MS/MS (liquid chromatography-tandem mass spectrometry). Selected metabolite candidates were synthesized and investigated for structural confirmation. Besides a high level of in vitro stability, the microsomal incubations revealed some species differences as well as enantiomer discrimination with regard to the formation of monohydroxylated products, which was identified as the main metabolic pathway in this assay. Furthermore, after injection of 250 MBq (+)-[18F]flubatine (specific activity > 350 GBq/μmol) into mouse, samples were prepared from brain, liver, plasma, and urine after 30 min and investigated by radio-HPLC (high performance liquid chromatography with radioactivity detection). For structure elucidation of the radiometabolites of (+)-[18F]flubatine formed in vivo, identical chromatographic conditions were applied to LC-MS/MS and radio-HPLC to compare samples obtained in vitro and in vivo. By this correlation approach, we assigned three of four main in vivo radiometabolites to products that are exclusively C- or N-hydroxylated at the azabicyclic ring system of the parent molecule.
Collapse
|
7
|
van der Wildt B, Lammertsma AA, Drukarch B, Windhorst AD. Strategies towards in vivo imaging of active transglutaminase type 2 using positron emission tomography. Amino Acids 2016; 49:585-595. [PMID: 27380031 PMCID: PMC5332496 DOI: 10.1007/s00726-016-2288-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Accepted: 06/22/2016] [Indexed: 01/04/2023]
Abstract
Transglutaminase type 2 (TG2) is increasingly linked to the pathogenesis of several diseases, such as celiac disease, cancer, and fibrotic and neurodegenerative diseases. In parallel with becoming an attractive target for therapy, interest in the development of compounds for in vivo imaging of TG2 is rising. Such imaging biomarkers might assist in clarifying the role of TG2 in pathology and in monitoring TG2 inhibition in vivo and thus assist in drug development. In this review, the latest results together with various strategies in TG2 PET tracer development are discussed, including radiolabelling of irreversible and reversible active-site inhibitors, as well as allosteric inhibitors, acyl-donor and acyl-acceptor substrates, and anti-TG2 monoclonal antibodies.
Collapse
Affiliation(s)
- Berend van der Wildt
- Departments of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands.
- Departments of Anatomy and Neurosciences, VU University Medical Center, Amsterdam, The Netherlands.
| | - Adriaan A Lammertsma
- Departments of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
| | - Benjamin Drukarch
- Departments of Anatomy and Neurosciences, VU University Medical Center, Amsterdam, The Netherlands
| | - Albert D Windhorst
- Departments of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
8
|
In vitro permeability, pharmacokinetics and brain uptake of WAY-100635 and FCWAY in rats using liquid chromatography electrospray ionization tandem mass spectrometry. Arch Pharm Res 2014; 38:1072-9. [PMID: 24838378 DOI: 10.1007/s12272-014-0369-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2013] [Accepted: 03/13/2014] [Indexed: 01/16/2023]
Abstract
Positron emission tomography (PET) is a sensitive non-invasive imaging technique. To reduce imaging measurements of defects, there is a demand for proper LC-ESI-MS/MS method to carry out with its specificity and sensitivity. This study describes a rapid and simple liquid chromatography electrospray ionization tandem-MS/MS (LC-ESI-MS/MS) method for determination of both PET tracers: N-[2-[4-(2-methoxyphenyl)-1-piperazinyl]ethyl]-N-(2-pyridyl)cyclohexanecarboxamide (WAY-100635) and 4-fluoro-N-[2-[4-(2-methoxylphenyl)-1-piperazino]ethyl]-N-(2-pyridyl)cyclohexanecarboxamide (FCWAY). Both target compounds were prepared by one-step protein precipitation with acetonitrile and methanol (1:1, v/v), and analyzed using a C18 column. This simple method has an excellent linearity, selectivity and sensitivity. Precision and accuracy values for the intra-day and inter-day validation were below 12%. The limit of quantification (LOQ) for both target compounds was defined as 1 ng/mL in plasma and 5 ng/mL in brain homogenate. The stability of both compounds is considered stable under a various experimental conditions. The in vitro MDR-MDCK cell permeability showed the both compounds have high permeability (Papp, A→B ≥ 20 × 10(-6 )cm/s) and low efflux ratio (≤2.0). Brain to blood (AUCbrain/AUCblood) distribution ratios in rats were 3.15 ± 0.42 for WAY-100635 and 2.20 ± 0.34 for FCWAY, respectively, and these results suggest that LC-ESI-MS/MS method might be a supplementary way for the identifying and understanding of radiopharmaceuticals.
Collapse
|
9
|
Amini N, Nakao R, Schou M, Halldin C. Identification of PET radiometabolites by cytochrome P450, UHPLC/Q-ToF-MS and fast radio-LC: applied to the PET radioligands [11C]flumazenil, [18F]FE-PE2I, and [11C]PBR28. Anal Bioanal Chem 2012. [DOI: 10.1007/s00216-012-6541-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
10
|
Ketola RA, Mauriala T. Mass spectrometric tools for cell and tissue studies. Eur J Pharm Sci 2012; 46:293-314. [DOI: 10.1016/j.ejps.2012.03.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2012] [Revised: 03/14/2012] [Accepted: 03/23/2012] [Indexed: 10/28/2022]
|
11
|
Du J, Zhu L, Zhou X, Yin W, Deng A, Qiao J. Dose-response relationships of FMISO between trace dose and various macro-doses in rat by ultra-performance liquid chromatography with mass spectrometry and radioactivity analysis. J Pharm Biomed Anal 2012; 70:499-504. [PMID: 22867691 DOI: 10.1016/j.jpba.2012.07.016] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Revised: 07/13/2012] [Accepted: 07/14/2012] [Indexed: 12/27/2022]
Abstract
Screening the pharmacokinetics of candidates using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) may be efficacious and safe for the research and development of new PET imaging agents. However, the PET imaging agent is administered as trace dose and the sensitivity of LC-MS/MS is often insufficient. If the dose was increased to be quantifiable, it should be necessary to prove whether the pharmacokinetics between trace and macro-doses is consistent or not. In this paper, fluoromisonidazole (FMISO), a tumor PET imaging agent, was chosen to evaluate the dose-response pharmacokinetics by administering various single intravenous doses (0.1, 0.4, 1.6 and 6.4 mg/kg) in male Sprague-Dawley rats. The plasma concentration of FMISO was determined by an ultra-performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method, and the blood radioactivity of [(18)F]FMISO was detected by a gamma counter. By calculating and comparing the pharmacokinetic parameters, the total area under the plasma concentration-time curve from time zero to infinity (AUC(0-∞)) and peak plasma concentration (C(max)) values increased with the selected FMISO doses, and showing linear dose-dependent. On the other hand, some parameters related to time, such as the elimination half-lives (t(1/2)) and elimination rate constant (K(e)) were dose-independent, and there is no significant deference between trace dose and various macro-doses. The data should be useful to evaluate the novel 2-nitroimidazole derivatives as potential PET tumor imaging agents.
Collapse
Affiliation(s)
- Jinglei Du
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, PR China
| | | | | | | | | | | |
Collapse
|
12
|
Nakao R, Schou M, Halldin C. Rapid and sensitive measurement of PET radioligands in plasma by fast liquid chromatography/radiometric detection. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 895-896:116-22. [DOI: 10.1016/j.jchromb.2012.03.028] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Revised: 03/05/2012] [Accepted: 03/18/2012] [Indexed: 11/29/2022]
|
13
|
Zhou X, Qiao J, Yin W, Zhu L, Kung HF. Determination of the penetration of 9-fluoropropyl-(+)-dihydrotetrabenazine across the blood-brain barrier in rats by microdialysis combined with liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:3041-6. [PMID: 21937290 DOI: 10.1016/j.jchromb.2011.08.043] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 08/16/2011] [Accepted: 08/30/2011] [Indexed: 11/19/2022]
Abstract
To evaluate the penetration of the blood-brain barrier by 9-fluoropropyl-(+)-dihydrotetrabenazine (AV-133), microdialysis probes were implanted simultaneously into rat blood and brain, and a liquid chromatography-tandem mass spectrometric method was developed and validated to monitor the AV-133 concentration in the microdialysates. The chromatographic separation was performed on an XTerra C(18) column (150 mm × 2.1 mm i.d., 5 μm particles) with gradient elution. The mass spectrometer was operated in positive mode using electrospray ionization. The analytes were measured using the multiple-reaction-monitoring mode. The calibration curves were linear over the range of 5.00-1000 ng/mL AV-133, with a coefficient of determination >0.995. The accuracies ranged from 99.5% to 105.0% and the precisions were <10% for AV-133. This method was used to determine the concentrations of AV-133 and its pharmacokinetics in the brains and blood of rats. The blood and brain concentration-time profiles for AV-133 were obtained, and the blood-brain barrier penetration was evaluated.
Collapse
Affiliation(s)
- Xue Zhou
- Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, PR China
| | | | | | | | | |
Collapse
|
14
|
LC/MS evaluation of metabolism and membrane transport of bombesin peptides. Amino Acids 2010; 40:669-75. [PMID: 20676905 DOI: 10.1007/s00726-010-0696-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2010] [Accepted: 07/10/2010] [Indexed: 10/19/2022]
Abstract
Two bombsin peptides, GRPR agonist [Aca-QWAVGHLM-NH(2)] and antagonist [fQWAVGHL-NHEthyl] were evaluated. We employed the highly sensitive Waters Q-Tof Premier MS coupled with a UPLC system to identify the metabolites produced by rat hepatocytes or PC-3 human prostate cancer cells; and we utilized the AB/MDS 4000 Q-Trap LC/MS/MS system with highly sensitive quantitative and qualitative performance, to quantitatively analyze the internalization of GRPR agonist and antagonist in PC-3 cells. The major metabolites of both GRPR agonist and antagonist were the result of peptide bond hydrolysis between W and A which was demonstrated by observation of the N-terminal fragment m/z 446 (Aca-QW-OH) for agonist and m/z 480 (fQW-OH) for antagonist. Both peptides were also hydrolyzed between A and V which formed peaks m/z 517 [Aca-QWA-OH] and m/z 555 (VGHLM-NH2) for the agonist and m/z 551 [fQWA-OH] and m/z 452 (VGHL-NHEthyl) for the antagonist. The peptide agonist also formed a unique metabolite that resulted from hydrolysis of the C-terminal amide. The antagonist showed significantly slower metabolism as compared to the agonist in both rat hepatocytes and PC-3 cells. The antagonist also showed significantly lower PC-3 cell internalization rate than that of the agonist. In conclusion, the metabolism profiles of both GRPR agonist and antagonist peptides were identified by LC/MS. The antagonist peptide was more stable than the agonist peptide in rat hepatocyte incubation. One major factor could be the hydrolysis-resistant C-terminal L-NHEthyl group compared with the unsubstituted amide of the agonist. Another factor could be different amino acid sequences of the agonist and antagonist that may also influence the enzymatic hydrolysis. The antagonist ligand is potentially more useful for receptor-targeted imaging due primarily to its higher metabolic stability.
Collapse
|