1
|
Gómez-Álvarez J, Miranda I, Álvarez-Llanas A, Lisón JF, Bosch-Morell F, Doménech J. Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty. J Clin Med 2024; 13:527. [PMID: 38256664 PMCID: PMC10816639 DOI: 10.3390/jcm13020527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 12/30/2023] [Accepted: 01/16/2024] [Indexed: 01/24/2024] Open
Abstract
BACKGROUND Metal-on-metal (M-M) total hip arthroplasty (THA) has shown adverse reactions to metal debris, abnormal soft-tissue reactions, and high blood metal ion levels. This study aims to: (1) assess whether the toxicity of high levels of ions is related to altered oxidative stress and (2) evaluate tribological factors related to increased blood levels of chromium (Cr) and cobalt (Co) ions. METHODS A cross-sectional analytical descriptive study was conducted on 75 patients. A total of 25 underwent M-M THA, 25 ceramic-on-metal (C-M) THA, and 25 were on the THA waiting list. Ion metallic levels in blood, oxidative stress, physical activity, and implant position were compared. RESULTS In the M-M group, Co and Cr levels were significantly higher than those found in the C-M group and the control group (p < 0.01). We found no differences in terms of oxidative stress between the groups. Also, we did not find a correlation between metal blood levels and oxidative stress indicators, the physical activity of the patients or the position of the implants between groups. CONCLUSIONS The use of M-M bearing surfaces in THA raises the levels of metals in the blood without modifying oxidative stress regardless of the physical activity levels of the patients. Therefore, although patients with M-M bearings require close monitoring, it does not seem necessary to recommend the restriction of physical activity in patients with M-M or C-M arthroplasties.
Collapse
Affiliation(s)
- Jorge Gómez-Álvarez
- Department of Orthopedic Surgery, Clínica Universidad de Navarra, 31008 Pamplona, Spain;
| | - Ignacio Miranda
- Department of Orthopedic Surgery, Hospital Arnau de Vilanova, 46015 Valencia, Spain
- Faculty of Health Sciences, Universidad Católica de Valencia, 46001 Valencia, Spain
| | - Alejandro Álvarez-Llanas
- Department of Orthopedic Surgery, Hospital Arnau de Vilanova, 46015 Valencia, Spain
- Faculty of Health Sciences, Universidad Católica de Valencia, 46001 Valencia, Spain
| | - Juan F. Lisón
- Department of Biomedical Sciences, Faculty of Health Sciences, University CEU Cardenal Herrera, 46115 Alfara del Patriarca, Spain; (J.F.L.); (F.B.-M.)
- CIBER de Fisiopatología de la Obesidad y Nutrición, Instituto de Salud Carlos III, 28029 Madrid, Spain
| | - Francisco Bosch-Morell
- Department of Biomedical Sciences, Faculty of Health Sciences, University CEU Cardenal Herrera, 46115 Alfara del Patriarca, Spain; (J.F.L.); (F.B.-M.)
| | - Julio Doménech
- Department of Orthopedic Surgery, Clínica Universidad de Navarra, 31008 Pamplona, Spain;
| |
Collapse
|
2
|
Skrajnowska D, Jagielska A, Ruszczyńska A, Idkowiak J, Bobrowska-Korczak B. Effect of Copper and Selenium Supplementation on the Level of Elements in Rats' Femurs under Neoplastic Conditions. Nutrients 2022; 14:1285. [PMID: 35334941 PMCID: PMC8951585 DOI: 10.3390/nu14061285] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 03/11/2022] [Accepted: 03/16/2022] [Indexed: 02/04/2023] Open
Abstract
A study was conducted to determine the effect of long-term supplementation with selenium and copper, administered at twice the level used in the standard diet of rats, on the content of selected elements in the femoral bones of healthy rats and rats with implanted LNCaP cancer cells. After an adaptation period, the animals were randomly divided into two experimental groups. The rats in the experimental group were implanted with prostate cancer cells. The rats in the control group were kept in the same conditions as those in the experimental group and fed the same diet, but without implanted cancer cells. The cancer cells (LNCaP) were intraperitoneally implanted in the amount of 1 × 106 (in PBS 0.4 mL) at the age of 90 days. The content of elements in the samples was determined by a quadrupole mass spectrometer with inductively coupled plasma ionization (ICP-MS). In the femoral bones of rats with implanted LNCaP cells, in the case of the standard diet and the copper-enriched diet, there was a marked decreasing trend in the content of the analysed elements relative to the control rats. This may indicate slow osteolysis taking place in the bone tissue. Contrasting results were obtained for the diet enriched with selenium; there was no significant reduction in the level of these elements, and there was even an increase in the concentrations of Fe and K in the bones of rats with implanted LNCaP cells. Particularly, numerous changes in the mineral composition of the bones were generated by enriching the diet with copper. The elements that most often underwent changes (losses) in the bones were cobalt, iron, manganese and molybdenum. The changes observed, most likely induced by the implantation of LNCaP cells, may indicate a disturbance of mineral homeostasis.
Collapse
Affiliation(s)
- Dorota Skrajnowska
- Department of Bromatology, Faculty of Pharmacy, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland;
| | - Agata Jagielska
- Biological and Chemical Research Centre, Faculty of Chemistry, University of Warsaw, Zwirki i Wigury 101, 02-089 Warsaw, Poland; (A.J.); (A.R.)
| | - Anna Ruszczyńska
- Biological and Chemical Research Centre, Faculty of Chemistry, University of Warsaw, Zwirki i Wigury 101, 02-089 Warsaw, Poland; (A.J.); (A.R.)
| | - Jakub Idkowiak
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, 53210 Pardubice, Czech Republic;
| | - Barbara Bobrowska-Korczak
- Department of Bromatology, Faculty of Pharmacy, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland;
| |
Collapse
|
3
|
Shinners L, Aggar C, Grace S, Smith S. Exploring healthcare professionals' perceptions of artificial intelligence: Validating a questionnaire using the e-Delphi method. Digit Health 2021; 7:20552076211003433. [PMID: 33815816 PMCID: PMC7995296 DOI: 10.1177/20552076211003433] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 02/23/2021] [Indexed: 01/15/2023] Open
Abstract
Objective The aim of this study was to draw upon the collective knowledge of experts in the fields of health and technology to develop a questionnaire that measured healthcare professionals' perceptions of Artificial Intelligence (AI). Methods The panel for this study were carefully selected participants who demonstrated an interest and/or involvement in AI from the fields of health or information technology. Recruitment was accomplished via email which invited the panel member to participate and included study and consent information. Data were collected from three rounds in the form of an online survey, an online group meeting and email communication. A 75% median threshold was used to define consensus. Results Between January and March 2019, five healthcare professionals and three IT experts participated in three rounds of study to reach consensus on the structure and content of the questionnaire. In Round 1 panel members identified issues about general understanding of AI and achieved consensus on nine draft questionnaire items. In Round 2 the panel achieved consensus on demographic questions and comprehensive group discussion resulted in the development of two further questionnaire items for inclusion. In a final e-Delphi round, a draft of the final questionnaire was distributed via email to the panel members for comment. No further amendments were put forward and 100% consensus was achieved. Conclusion A modified e-Delphi method was used to validate and develop a questionnaire to explore healthcare professionals' perceptions of AI. The e-Delphi method was successful in achieving consensus from an interdisciplinary panel of experts from health and IT. Further research is recommended to test the reliability of this questionnaire.
Collapse
Affiliation(s)
- Lucy Shinners
- Faculty of Health, Southern Cross University, Gold Coast Airport, Bilinga, Australia
| | - Christina Aggar
- Faculty of Health, Southern Cross University, Gold Coast Airport, Bilinga, Australia
| | - Sandra Grace
- Faculty of Health, Southern Cross University, East Lismore, Australia
| | - Stuart Smith
- Faculty of Health, Southern Cross University, Coffs Harbour, Australia
| |
Collapse
|
4
|
Dias Corpa Tardelli J, Bolfarini C, Cândido Dos Reis A. Comparative analysis of corrosion resistance between beta titanium and Ti-6Al-4V alloys: A systematic review. J Trace Elem Med Biol 2020; 62:126618. [PMID: 32663743 DOI: 10.1016/j.jtemb.2020.126618] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 06/19/2020] [Accepted: 07/08/2020] [Indexed: 01/20/2023]
Abstract
BACKGROUND The knowledge of the electrochemical property (corrosion resistance) of beta titanium alloys compared to Ti-6Al-4 V for implants is relevant because of the potential cytotoxic effects that the released ions could cause to long-term health. OBJECTIVES The objective of this systematic review was to seek information on the electrochemical properties (corrosion resistance) of beta titanium alloys compared to Ti-6Al-4 V since the awareness of the electrochemical behavior of the implant surface in the medium is essential for the best indication of the alloys or compositional changes, which may promote benefits to bone-implant interaction in all areas that this procedure is required. METHODS The PubMed, LILACS, COCHRANE Library, and Science Direct databases were electronically searched for the terms: dental implants AND beta-titanium AND Ti-6Al-4 V AND electrochemical technics. The inclusion criteria were research articles that studied beta-titanium compared to Ti-6Al-4 V using electrochemical techniques in electrolytes of chemical composition similar to body fluid, published in English, between 2000 and 2020. Articles that did not compare the corrosion resistance of these alloys in electrolytes similar to body fluids were excluded. RESULTS A total of 189 articles were restored and selected by title and/or abstract according to the inclusion and exclusion criteria, which resulted in 15 articles that were reduced to 8 after read in full. The studies in vitro evaluated the corrosion resistance in electrolytes Hank, Ringer, SBF, and 0.9 % NaCl, between beta titanium alloys, obtained by arc fusion or bars stock, and Ti-6Al-4 V, for dental or biomedical implants submitted to surface treatments by heat treatment, plasma electrolytic oxidation (PEO), alkaline treatment, and thermomechanical. CONCLUSION The evaluated literature allowed to determine that 1) The oxides Nb2O 5, Ta2O 5, and ZrO2 have higher stability and protection quality than that of TiO2 modified by the oxides of Al and V; 2) A higher modulus of elasticity of the Ti-6Al-4 V alloy favors protection against corrosion by maintaining a thicker and more firmly adhered oxide layer; 3) The increase in the thickness of the Ti alloys superficial layer contributes to the improvement of the corrosion resistance.
Collapse
Affiliation(s)
- Juliana Dias Corpa Tardelli
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
| | - Claudemiro Bolfarini
- Department of Materials Engineering, Federal University of São Carlos (UFSCAR), São Carlos, SP, Brazil.
| | - Andréa Cândido Dos Reis
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil.
| |
Collapse
|
5
|
Qin HM, Herrera D, Liu DF, Chen CQ, Nersesyan A, Mišík M, Knasmueller S. Genotoxic properties of materials used for endoprostheses: Experimental and human data. Food Chem Toxicol 2020; 145:111707. [PMID: 32889016 DOI: 10.1016/j.fct.2020.111707] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 08/13/2020] [Accepted: 08/22/2020] [Indexed: 12/28/2022]
Abstract
Approximately 2 million endoprostheses are implanted annually and metal ions as well as particles are released into the body from the materials which are used. This review describes the results of studies concerning genotoxic damage caused by artificial joints. DNA damage leads to various adverse long-term health effects in humans including cancer. Experiments with mammalian cells showed that metal ions and particles from orthopedic materials cause DNA damage. Induction of chromosomal aberrations (CA) was found in several in vitro experiments and in studies with rodents with metals from orthopedic materials. Human studies focused mainly on induction of CA (7 studies). Only few investigations (4) concerned sister chromatid exchanges, oxidative DNA damage (2) and micronucleus formation (1). CA are a reliable biomarker for increased cancer risks in humans) and were increased in all studies in patients with artificial joints. No firm conclusion can be drawn at present if the effects in humans are due to oxidative stress and if dissolved metal ions or release particles play a role. Our findings indicate that patients with artificial joints may have increased cancer risks due to damage of the genetic material. Future studies should be performed to identify safe materials and to study the molecular mechanisms in detail.
Collapse
Affiliation(s)
- Hong-Min Qin
- Hip Surgery of Orthopedic Hospital, Affiliated Hospital of Panzhihua University, Panzhihua, 617000, Sichuan Province, China
| | - Denise Herrera
- Institute of Cancer Research, Department of Internal Medicine I, Medical University of Vienna, 1090, Borschkegasse 8A, Vienna, Austria
| | - Dian-Feng Liu
- Hip Surgery of Orthopedic Hospital, Affiliated Hospital of Panzhihua University, Panzhihua, 617000, Sichuan Province, China
| | - Chao-Qian Chen
- Hip Surgery of Orthopedic Hospital, Affiliated Hospital of Panzhihua University, Panzhihua, 617000, Sichuan Province, China
| | - Armen Nersesyan
- Institute of Cancer Research, Department of Internal Medicine I, Medical University of Vienna, 1090, Borschkegasse 8A, Vienna, Austria
| | - Miroslav Mišík
- Institute of Cancer Research, Department of Internal Medicine I, Medical University of Vienna, 1090, Borschkegasse 8A, Vienna, Austria
| | - Siegfried Knasmueller
- Institute of Cancer Research, Department of Internal Medicine I, Medical University of Vienna, 1090, Borschkegasse 8A, Vienna, Austria.
| |
Collapse
|
6
|
Hameister R, Kaur C, Dheen ST, Lohmann CH, Singh G. Reactive oxygen/nitrogen species (ROS/RNS) and oxidative stress in arthroplasty. J Biomed Mater Res B Appl Biomater 2020; 108:2073-2087. [PMID: 31898397 DOI: 10.1002/jbm.b.34546] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/19/2019] [Accepted: 12/08/2019] [Indexed: 12/16/2022]
Abstract
The interplay between implant design, biomaterial characteristics, and the local microenvironment adjacent to the implant is of utmost importance for implant performance and success of the joint replacement surgery. Reactive oxygen and nitrogen species (ROS/RNS) are among the various factors affecting the host as well as the implant components. Excessive formation of ROS and RNS can lead to oxidative stress, a condition that is known to damage cells and tissues and also to affect signaling pathways. It may further compromise implant longevity by accelerating implant degradation, primarily through activation of inflammatory cells. In addition, wear products of metallic, ceramic, polyethylene, or bone cement origin may also generate oxidative stress themselves. This review outlines the generation of free radicals and oxidative stress in arthroplasty and provides a conceptual framework on its implications for soft tissue remodeling and bone resorption (osteolysis) as well as implant longevity. Key findings derived from cell culture studies, animal models, and patients' samples are presented. Strategies to control oxidative stress by implant design and antioxidants are explored and areas of controversy and challenges are highlighted. Finally, directions for future research are identified. A better understanding of the host-implant interplay and the role of free radicals and oxidative stress will help to evaluate therapeutic approaches and will ultimately improve implant performance in arthroplasty.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shaikali Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Gurpal Singh
- Centre for Orthopaedics Pte Ltd, Singapore, Singapore
| |
Collapse
|
7
|
Kovochich M, Finley BL, Novick R, Monnot AD, Donovan E, Unice KM, Fung ES, Fung D, Paustenbach DJ. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review. Crit Rev Toxicol 2019; 48:853-901. [DOI: 10.1080/10408444.2018.1563048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
8
|
Abstract
Healthcare is at a different place than it once was, over the past few decades, there has been an accelerated revolution with information technology (IT) and how it is used. Electronic Health Record (EHR) systems are a common healthcare IT deemed as a crucial step in advancing healthcare with both positive and negative impacts. Many unintended consequences stem from technical issues and/or sociotechnical issues – workflows, culture and interactions with the EHR system. The complexity of both the healthcare industry and EHR systems demonstrate the criticality to keep investigating and addressing issues with interaction of the two. This paper reports on the common factors leading to unintended consequences and medical errors, while exploring mitigation factors to address the associated risks.
Collapse
|
9
|
Hemsley B, Georgiou A, Carter R, Hill S, Higgins I, van Vliet P, Balandin S. Use of the My Health Record by people with communication disability in Australia: A review to inform the design and direction of future research. Health Inf Manag 2016; 45:107-115. [PMID: 27269277 DOI: 10.1177/1833358316652060] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/05/2016] [Indexed: 12/17/2022]
Abstract
BACKGROUND People with communication disability often struggle to convey their health information to multiple service providers and are at increased risk of adverse health outcomes related to the poor exchange of health information. OBJECTIVE The purpose of this article was to (a) review the literature informing future research on the Australian personally controlled electronic health record, 'My Health Record' (MyHR), specifically to include people with communication disability and their family members or service providers, and (b) to propose a range of suitable methodologies that might be applied in research to inform training, policy and practice in relation to supporting people with communication disability and their representatives to engage in using MyHR. METHOD The authors reviewed the literature and, with a cross-disciplinary perspective, considered ways to apply sociotechnical, health informatics, and inclusive methodologies to research on MyHR use by adults with communication disability. RESEARCH OUTCOMES This article outlines a range of research methods suitable for investigating the use of MyHR by people who have communication disability associated with a range of acquired or lifelong health conditions, and their family members, and direct support workers. CONCLUSION In planning the allocation of funds towards the health and well-being of adults with disabilities, both disability and health service providers must consider the supports needed for people with communication disability to use MyHR. There is an urgent need to focus research efforts on MyHR in populations with communication disability, who struggle to communicate their health information across multiple health and disability service providers. The design of studies and priorities for future research should be set in consultation with people with communication disability and their representatives.
Collapse
|
10
|
Savarino L, Fotia C, Roncuzzi L, Greco M, Cadossi M, Baldini N, Giannini S. Does chronic raise of metal ion levels induce oxidative DNA damage and hypoxia-like response in patients with metal-on-metal hip resurfacing? J Biomed Mater Res B Appl Biomater 2015; 105:460-466. [PMID: 26477446 DOI: 10.1002/jbm.b.33555] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 06/24/2015] [Accepted: 10/03/2015] [Indexed: 02/06/2023]
Abstract
Metal-on-metal hip resurfacing (MOM-HR) represents a viable alternative to traditional arthroplasty. Nevertheless, in MOM coupling both metal nanoparticles and ions are released, whose toxicity remains a matter of concern. We investigated whether 'endogenous' chronic exposure to cobalt and chromium induced a state of oxidative stress, DNA damage and a hypoxia-like response in patients with well-functioning MOM-HR. Twenty-two patients with unilateral MOM-HR were recruited at long-term. Twenty-one osteoarthritic subjects were enrolled for comparison. Serum ion levels were measured and correlated with 8-hydroxydeoxyguanosine and circulating-free-DNA, as markers of oxidative DNA damage. Moreover, the hypoxia-inducible factor-1α, marker of hypoxic state, was evaluated. Ion concentrations were found to be 5-to-15 times higher in MOM-HR patients than in presurgery subjects (p < 0.001); circulating-free-DNA, 8-hydroxydeoxyguanosine, and hypoxia-inducible factor-1α levels were not significantly different between groups and did not correlate with ion levels. Analyzing the results according to gender, MOM-HR males had higher 8-hydroxydeoxyguanosine levels (p = 0.01) compared with MOM-HR females. Similarly, circulating-free-DNA values were higher in males than females, even if this difference did not reach statistical significance. This research is the first that attempted to investigate the long-term effects of ion dissemination in subjects with well-fixed MOM implants. A significant correlation between biomarkers increase and ion levels was not demonstrated. Nevertheless, both circulating-free-DNA and 8-hydroxydeoxyguanosine showed a tendency to increase in MOM-HR males. Further studies with a larger sample size should be performed to detect the clinical relevance of biomarkers increase especially in younger subjects, where a chronic moderately elevated exposure has to be faced. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 460-466, 2017.
Collapse
Affiliation(s)
- Lucia Savarino
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Caterina Fotia
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Laura Roncuzzi
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Michelina Greco
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Matteo Cadossi
- Department I of Orthopaedics and Traumatology, Rizzoli Orthopedic Institute, Bologna, Italy
| | - Nicola Baldini
- Laboratory for Orthopaedic Pathophysiology and Regenerative Medicine, Rizzoli Orthopaedic Institute, Bologna, Italy.,Department of Biomedical and Neuromotor Sciences, Bologna University, Bologna, Italy
| | - Sandro Giannini
- Department I of Orthopaedics and Traumatology, Rizzoli Orthopedic Institute, Bologna, Italy.,Department of Biomedical and Neuromotor Sciences, Bologna University, Bologna, Italy
| |
Collapse
|
11
|
Yusof MM. A case study evaluation of a Critical Care Information System adoption using the socio-technical and fit approach. Int J Med Inform 2015; 84:486-99. [PMID: 25881560 DOI: 10.1016/j.ijmedinf.2015.03.001] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2014] [Revised: 03/08/2015] [Accepted: 03/09/2015] [Indexed: 11/15/2022]
Abstract
BACKGROUND Clinical information systems have long been used in intensive care units but reports on their adoption and benefits are limited. This study evaluated a Critical Care Information System implementation. METHODS A case study summative evaluation was conducted, employing observation, interview, and document analysis in operating theatres and 16-bed adult intensive care units in a 400-bed Malaysian tertiary referral centre from the perspectives of users (nurses and physicians), management, and information technology staff. System implementation, factors influencing adoption, fit between these factors, and the impact of the Critical Care Information System were evaluated after eight months of operation. RESULTS Positive influences on system adoption were associated with technical factors, including system ease of use, usefulness, and information relevancy; human factors, particularly user attitude; and organisational factors, namely clinical process-technology alignment and champions. Organisational factors such as planning, project management, training, technology support, turnover rate, clinical workload, and communication were barriers to system implementation and use. Recommendations to improve the current system problems were discussed. Most nursing staff positively perceived the system's reduction of documentation and data access time, giving them more time with patients. System acceptance varied among doctors. System use also had positive impacts on timesaving, data quality, and clinical workflow. CONCLUSIONS Critical Care Information Systems is crucial and has great potentials in enhancing and delivering critical care. However, the case study findings showed that the system faced complex challenges and was underutilised despite its potential. The role of socio-technical factors and their fit in realizing the potential of Critical Care Information Systems requires continuous, in-depth evaluation and stakeholder understanding and acknowledgement. The comprehensive and specific evaluation measures of the Human-Organisation-Technology Fit framework can flexibly evaluate Critical Care Information Systems.
Collapse
Affiliation(s)
- Maryati Mohd Yusof
- Centre for Software Technology and Management, Faculty of Information Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia.
| |
Collapse
|
12
|
Posada OM, Tate RJ, Grant MH. Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells. Toxicol In Vitro 2014; 29:271-80. [PMID: 25433333 DOI: 10.1016/j.tiv.2014.11.006] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2014] [Revised: 11/07/2014] [Accepted: 11/18/2014] [Indexed: 12/12/2022]
Abstract
Hip resurfacing with cobalt-chromium (CoCr) alloy was developed as a surgical alternative to total hip replacement. However, the biological effects of nanoparticles generated by wear at the metal-on-metal articulating surfaces has limited the success of such implants. The aim of this study was to investigate the effects of the combined exposure to CoCr nanoparticles and cobalt ions released from a resurfacing implant on monocytes (U937 cells) and whether these resulted in morphology changes, proliferation alterations, toxicity and cytokine release. The interaction between prior exposure to Co ions and the cellular response to nanoparticulate debris was determined to simulate the situation in patients with metal-on-metal implants receiving a second implant. Effects on U937 cells were mainly seen after 120h of treatment. Prior exposure to Co ions increased the toxic effects induced by the debris, and by Co ions themselves, suggesting the potential for interaction in vivo. Increased TNF-α secretion by resting cells exposed to nanoparticles could contribute to osteolysis processes in vivo, while increased IFN-γ production by activated cells could represent cellular protection against tissue damage. Data suggest that interactions between Co ions and CoCr nanoparticles would occur in vivo, and could threaten the survival of a CoCr metal implant.
Collapse
Affiliation(s)
- Olga M Posada
- Biomedical Engineering Department, University of Strathclyde, Wolfson Centre, Glasgow G4 0NW, UK.
| | - Rothwelle J Tate
- Strathclyde Institute for Pharmacy & Biomedical Sciences, University of Strathclyde, Glasgow G4 0RE, UK.
| | - M Helen Grant
- Biomedical Engineering Department, University of Strathclyde, Wolfson Centre, Glasgow G4 0NW, UK.
| |
Collapse
|
13
|
Matusiewicz H. Potential release of in vivo trace metals from metallic medical implants in the human body: from ions to nanoparticles--a systematic analytical review. Acta Biomater 2014; 10:2379-403. [PMID: 24565531 DOI: 10.1016/j.actbio.2014.02.027] [Citation(s) in RCA: 116] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/04/2013] [Accepted: 02/13/2014] [Indexed: 02/06/2023]
Abstract
Metal ion release from metallic materials, e.g. metallic alloys and pure metals, implanted into the human body in dental and orthopedic surgery is becoming a major cause for concern. This review briefly provides an overview of both metallic alloys and pure metals used in implant materials in dental and orthopedic surgery. Additionally, a short section is dedicated to important biomaterials and their corrosive behavior in both real solutions and various types of media that model human biological fluids and tissues. The present review gives an overview of analytical methods, techniques and different approaches applied to the measurement of in vivo trace metals released into body fluids and tissues from patients carrying metal-on-metal prostheses and metal dental implants. Reference levels of ion concentrations in body fluids and tissues that have been determined by a host of studies are compiled, reviewed and presented in this paper. Finally, a collection of published clinical data on in vivo released trace metals from metallic medical implants is included.
Collapse
|
14
|
Unnithan C. RFID Implementation in Australian Hospitals. INTERNATIONAL JOURNAL OF ENTERPRISE INFORMATION SYSTEMS 2014. [DOI: 10.4018/ijeis.2014040103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Radio Frequency Identification (RFID) is a mobile technology that was explored in hospitals in the last decade for improving process efficiencies. However, in the Australian context, this technology is still regarded as an innovation that health ICT practitioners and hospitals are reluctant to trial. This technology, although non-intrusive, is perceived as disruptive by hospitals. Information Systems professionals in the ICT sector and Health Informatics practitioners in Australia are exploring best practices for implementation. In this research paper, I report on findings from empirical research that was conducted in Australia, based in two large hospitals1, to better understand the factors involved in the successful implementation of RFID in Australian hospitals. Findings from this study are presented and endorsed by health ICT practitioners and informatics professionals as current implications for the field.
Collapse
Affiliation(s)
- Chandana Unnithan
- Faculty of Business and Law, Deakin University, Melbourne, Australia
| |
Collapse
|
15
|
In-vitro-Analyse des Einflusses von Metallionen auf humane Lymphozyten. DER ORTHOPADE 2013; 42:643-50. [DOI: 10.1007/s00132-012-2039-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
16
|
Wilson JM, Jones N, Jin L, Shin YC. Laser deposited coatings of Co-Cr-Mo onto Ti-6Al-4V and SS316L substrates for biomedical applications. J Biomed Mater Res B Appl Biomater 2013; 101:1124-32. [PMID: 23564675 DOI: 10.1002/jbm.b.32921] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2012] [Revised: 11/06/2012] [Accepted: 12/26/2012] [Indexed: 11/07/2022]
Affiliation(s)
- J. Michael Wilson
- School of Mechanical Engineering; Purdue University, Center for Laser-Based Manufacturing; West Lafayette IN 47907
| | - Nolan Jones
- School of Mechanical Engineering; Purdue University, Center for Laser-Based Manufacturing; West Lafayette IN 47907
| | - Li Jin
- School of Mechanical Engineering; Purdue University, Center for Laser-Based Manufacturing; West Lafayette IN 47907
| | - Yung C. Shin
- School of Mechanical Engineering; Purdue University, Center for Laser-Based Manufacturing; West Lafayette IN 47907
| |
Collapse
|
17
|
|
18
|
Afolaranmi GA, Akbar M, Brewer J, Grant MH. Distribution of metal released from cobalt-chromium alloy orthopaedic wear particles implanted into air pouches in mice. J Biomed Mater Res A 2012; 100:1529-38. [DOI: 10.1002/jbm.a.34091] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Revised: 12/10/2011] [Accepted: 01/10/2012] [Indexed: 11/11/2022]
|