He Y, Feng Y, Qiu D, Lin M, Jin H, Hu Z, Huang X, Ma S, He Y, Lai M, Jin W, Liu J. Regulation of IFP in solid tumors through acoustic pressure to enhance infiltration of nanoparticles of various sizes. J Drug Target 2024:1-16. [PMID: 38884143 DOI: 10.1080/1061186x.2024.2367579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Accepted: 06/07/2024] [Indexed: 06/18/2024]
Abstract
Numerous nanomedicines have been developed recently that can accumulate selectively in tumors due to the enhanced permeability and retention (EPR) effect. However, the high interstitial fluid pressure (IFP) in solid tumors limits the targeted delivery of nanomedicines. We were previously able to relieve intra-tumoral IFP by low-frequency non-focused ultrasound (LFNFU) through ultrasonic targeted microbubble destruction (UTMD), improving the targeted delivery of FITC-dextran. However, the accumulation of nanoparticles of different sizes and the optimal acoustic pressure were not evaluated. In this study, we synthesized Cy5.5-conjugated mesoporous silica nanoparticles (Cy5.5-MSNs) of different sizes using a one-pot method. The Cy5.5-MSNs exhibited excellent stability and biosafety regardless of size. MCF7 tumor-bearing mice were subjected to UTMD over a range of acoustic pressures (0.5/0.8/1.5/2.0MPa), and injected intravenously with Cy5.5-MSNs. Blood perfusion, tumor IFP and intra-tumoral accumulation of Cy5.5-MSNs were analyzed. Blood perfusion and IFP initially rose, and then declined, as acoustic pressure intensified. Furthermore, UTMD significantly enhanced the accumulation of differentially sized Cy5.5-MSNs in tumor tissues compared to that of the control group, and the increase was 7-fold higher at an acoustic pressure of 1.5MPa. Taken together, UTMD enhanced the infiltration and accumulation of Cy5.5-MSNs of different sizes in solid tumors by reducing intra-tumor IFP.
Collapse
Affiliation(s)
- Yangcheng He
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Yuyi Feng
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Danxai Qiu
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - MinHua Lin
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Hai Jin
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Zhiwen Hu
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Xue Huang
- Department of General Surgery, Zhujiang Hospital, Southern Medical University
| | - Suihong Ma
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Yan He
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Meiqi Lai
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Wenhui Jin
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| | - Jianhua Liu
- Department of Ultrasound, The Second Affliated Hospital, School of Medicine, South China University of Technology
| |
Collapse
|
2
|
Mpekris F, Panagi M, Charalambous A, Voutouri C, Michael C, Papoui A, Stylianopoulos T. A synergistic approach for modulating the tumor microenvironment to enhance nano-immunotherapy in sarcomas. Neoplasia 2024; 51:100990. [PMID: 38520790 PMCID: PMC10978543 DOI: 10.1016/j.neo.2024.100990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 03/08/2024] [Accepted: 03/12/2024] [Indexed: 03/25/2024]
Abstract
The lack of properly perfused blood vessels within tumors can significantly hinder the distribution of drugs, leading to reduced treatment effectiveness and having a negative impact on the quality of life of patients with cancer. This problem is particularly pronounced in desmoplastic cancers, where interactions between cancer cells, stromal cells, and the fibrotic matrix lead to tumor stiffness and the compression of most blood vessels within the tumor. To address this issue, two mechanotherapy approaches-mechanotherapeutics and ultrasound sonopermeation-have been employed separately to treat vascular abnormalities in tumors and have reached clinical trials. Here, we performed in vivo studies in sarcomas, to explore the conditions under which these two mechanotherapy strategies could be optimally combined to enhance perfusion and the efficacy of nano-immunotherapy. Our findings demonstrate that combination of the anti-histamine drug ketotifen, as a mechanotherapeutic, and sonopermeation effectively alleviates mechanical forces by decreasing 50 % collagen and hyaluronan levels and thus, reshaping the tumor microenvironment. Furthermore, the combined therapy normalizes the tumor vasculature by increasing two-fold the pericytes coverage. This combination not only improves six times tumor perfusion but also enhances drug delivery. As a result, blood vessel functionality is enhanced, leading to increased infiltration by 40 % of immune cells (CD4+ and CD8+ T-cells) and improving the antitumor efficacy of Doxil nanomedicine and anti-PD-1 immunotherapy. In conclusion, our research underscores the unique and synergistic potential of combining mechanotherapeutics and sonopermeation. Both approaches are undergoing clinical trials to enhance cancer therapy and have the potential to significantly improve nano-immunotherapy in sarcomas.
Collapse
Affiliation(s)
- Fotios Mpekris
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus.
| | - Myrofora Panagi
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus
| | - Antonia Charalambous
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus
| | - Chrysovalantis Voutouri
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus
| | - Christina Michael
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus
| | - Antonia Papoui
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus
| | - Triantafyllos Stylianopoulos
- Cancer Biophysics Laboratory, Department of Mechanical and Manufacturing Engineering, University of Cyprus, Cyprus.
| |
Collapse
|
3
|
Huang S, Shang M, Guo L, Sun X, Xiao S, Shi D, Meng D, Zhao Y, Wang X, Liu R, Li J. Hydralazine loaded nanodroplets combined with ultrasound-targeted microbubble destruction to induce pyroptosis for tumor treatment. J Nanobiotechnology 2024; 22:193. [PMID: 38643134 PMCID: PMC11031971 DOI: 10.1186/s12951-024-02453-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 04/01/2024] [Indexed: 04/22/2024] Open
Abstract
Pyroptosis, a novel type of programmed cell death (PCD), which provides a feasible therapeutic option for the treatment of tumors. However, due to the hypermethylation of the promoter, the critical protein Gasdermin E (GSDME) is lacking in the majority of cancer cells, which cannot start the pyroptosis process and leads to dissatisfactory therapeutic effects. Additionally, the quick clearance, systemic side effects, and low concentration at the tumor site of conventional pyroptosis reagents restrict their use in clinical cancer therapy. Here, we described a combination therapy that induces tumor cell pyroptosis via the use of ultrasound-targeted microbubble destruction (UTMD) in combination with DNA demethylation. The combined application of UTMD and hydralazine-loaded nanodroplets (HYD-NDs) can lead to the rapid release of HYD (a demethylation drug), which can cause the up-regulation of GSDME expression, and produce reactive oxygen species (ROS) by UTMD to cleave up-regulated GSDME, thereby inducing pyroptosis. HYD-NDs combined with ultrasound (US) group had the strongest tumor inhibition effect, and the tumor inhibition rate was 87.15% (HYD-NDs group: 51.41 ± 3.61%, NDs + US group: 32.73%±7.72%), indicating that the strategy had a more significant synergistic anti-tumor effect. In addition, as a new drug delivery carrier, HYD-NDs have great biosafety, tumor targeting, and ultrasound imaging performance. According to the results, the combined therapy reasonably regulated the process of tumor cell pyroptosis, which offered a new strategy for optimizing the therapy of GSDME-silenced solid tumors.
Collapse
Affiliation(s)
- Shuting Huang
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Mengmeng Shang
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Lu Guo
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Xiao Sun
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Shan Xiao
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Dandan Shi
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Dong Meng
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Yading Zhao
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Xiaoxuan Wang
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Rui Liu
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China
| | - Jie Li
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong, 250012, China.
- Department of Ultrasound, Qilu Hospital (Qingdao) of Shandong University, Qingdao, Shandong, 266035, China.
| |
Collapse
|
4
|
Eleje GU, Nwammuo CB, Nnamani KO, Igbodike EP, Nwankwo EU, Okafor CG, Njoku TK, Ekwebene OC, Egwuatu EC, Malachy DE, Dimgba OO, Ihekwoaba EC, Onu OA, Edokwe ES, Ofiaeli CI, Obi KE, Okwuosa CN, Egwim AV, Okoro CC, Onyejiaka CC, Nneji HC, Ugwu OD, Ezeigwe CO, Madubuko CC, Mathias AA, Udigwe GO. Double true umbilical cord knots coexisting with a nuchal cord with successful fetal outcome: A case report. SAGE Open Med Case Rep 2024; 12:2050313X241239524. [PMID: 38495733 PMCID: PMC10943703 DOI: 10.1177/2050313x241239524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 02/27/2024] [Indexed: 03/19/2024] Open
Abstract
Umbilical nodes and cords play a crucial role in fetal development and are essential for the transfer of nutrients and oxygen between the mother and the fetus. Sonographic diagnosis of umbilical nodes and cords has become an integral part of prenatal care, allowing for the early detection of abnormalities and potential complications. The umbilical cord is a vital structure connecting the fetus to the placenta, providing essential nutrients and oxygen for fetal growth and development. Sonographic examination of the umbilical cord and its associated nodes has become an indispensable tool in prenatal care, enabling the early detection of abnormalities and potential complications. This review aims to analyze the current literature on sonographic diagnosis of umbilical nodes and cords, highlighting the key points and advancements in this field. A 37-year-old booked G4P2+1A2 Nigerian woman was registered for prenatal tertiary health care at 12 weeks of gestation. The booking investigations were normal and the booking packed cell volume was 37%. She was compliant with scheduled clinic visits and routine drugs. Pregnancy was carried to term uneventfully. Elective cesarean section was successfully performed at 38 weeks of gestation owing to the patient's prior history of third-degree perineal tear. The intraoperative findings included a loose cord around the neck of the baby and double true knots along the length of the 65 cm umbilical cord. The baby was delivered with appearance, pulse, grimace, activity and respiration (APGAR) scores of 7 in the first minute, 9 in the fifth minute, and the birth weight was 3.0 kg. Mother and baby were discharged 48 h postpartum in stable clinical condition. Although the presence of true double umbilical knots is rare, its coexistence with the nuchal cord is even rarer. There are risk factors associated with true umbilical knots. The possible risk factor implicated in this index case is the gender of the fetus and maternal multiparity. True umbilical knots are usually associated with certain fetal negative outcomes of pregnancy. There are currently no evidence-based treatment options available.
Collapse
Affiliation(s)
- George Uchenna Eleje
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
- Effective Care Research Unit, Department of Obstetrics and Gynecology, Nnamdi Azikiwe University, Awka, Nigeria
| | - Chijioke Brenda Nwammuo
- Department of Radiology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Kenechi Ogbodo Nnamani
- Department of Paediatrics, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Emeka Philip Igbodike
- Department of Obstetrics and Gynecology, Havana Specialist Hospital, Surulere, Lagos, Nigeria
| | | | - Chigozie Geoffrey Okafor
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Tobechi Kingsley Njoku
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | | | | | | | - Ogechi Odinakachukwu Dimgba
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | | | - Onyekachi Amos Onu
- Department of Surgery, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria
| | - Emeka Stephen Edokwe
- Department of Paediatrics, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | | | - Kenechukwu Ezekwesili Obi
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Chizoba Ndidiamaka Okwuosa
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Adanna Vivian Egwim
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | | | | | - Henry Chinedu Nneji
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Obiora Donatus Ugwu
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Chijioke Ogomegbunam Ezeigwe
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Casmir Chukwudi Madubuko
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Alexander Arinze Mathias
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
| | - Gerald Okanandu Udigwe
- Department of Obstetrics and Gynecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria
- Effective Care Research Unit, Department of Obstetrics and Gynecology, Nnamdi Azikiwe University, Awka, Nigeria
| |
Collapse
|
5
|
Jiao H, Mao Q, Razzaq N, Ankri R, Cui J. Ultrasound technology assisted colloidal nanocrystal synthesis and biomedical applications. ULTRASONICS SONOCHEMISTRY 2024; 103:106798. [PMID: 38330546 PMCID: PMC10865478 DOI: 10.1016/j.ultsonch.2024.106798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 12/08/2023] [Accepted: 02/01/2024] [Indexed: 02/10/2024]
Abstract
Non-invasive and high spatiotemporal resolution mythologies for the diagnosis and treatment of disease in clinical medicine promote the development of modern medicine. Ultrasound (US) technology provides a non-invasive, real-time, and cost-effective clinical imaging modality, which plays a significant role in chemical synthesis and clinical translation, especially in in vivo imaging and cancer therapy. On the one hand, the US treatment is usually accompanied by cavitation, leading to high temperature and pressure, so-called "hot spot", playing a significant role in sonochemical-based colloidal synthesis. Compared with the classical nucleation synthetic method, the sonochemical synthesis strategy presents high efficiency for the fabrication of colloidal nanocrystals due to its fast nucleation and growth procedure. On the other hand, the US is attractive for in vivo and medical treatment, with applications increasing with the development of novel contrast agents, such as the micro and nano bubbles, which are widely used in neuromodulation, with which the US can breach the blood-brain barrier temporarily and safely, opening a new door to neuromodulation and therapy. In terms of cancer treatment, sonodynamic therapy and US-assisted synergetic therapy show great effects against cancer and sonodynamic immunotherapy present unparalleled potentiality compared with other synergetic therapies. Further development of ultrasound technology can revolutionize both chemical synthesis and clinical translation by improving efficiency, precision, and accessibility while reducing environmental impact and enhancing patient care. In this paper, we review the US-assisted sonochemical synthesis and biological applications, to promote the next generation US technology-assisted applications.
Collapse
Affiliation(s)
- Haorong Jiao
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China
| | - Qiulian Mao
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China
| | - Noman Razzaq
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China
| | - Rinat Ankri
- The Biomolecular and Nanophotonics Lab, Ariel University, 407000, P.O.B. 3, Ariel, Israel.
| | - Jiabin Cui
- The Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X) and Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Soochow University, 199 Renai Road, Industrial Park, Suzhou 215123, Jiangsu, China.
| |
Collapse
|
6
|
Ma RF, Xue LL, Liu JX, Chen L, Xiong LL, Wang TH, Liu F. Transcranial Doppler Ultrasonography detection on cerebral infarction and blood vessels to evaluate hypoxic ischemic encephalopathy modeling. Brain Res 2024; 1822:148580. [PMID: 37709160 DOI: 10.1016/j.brainres.2023.148580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 09/04/2023] [Accepted: 09/11/2023] [Indexed: 09/16/2023]
Abstract
BACKGROUND This study aimed to observe changes of rats' brain infarction and blood vessels during neonatal hypoxic ischemic encephalopathy (NHIE) modeling by Transcranial Doppler Ultrasonography (TCD) so as to assess the feasibility of TCD in evaluating NHIE modeling. METHODS Postnatal 7-days (d)-old Sprague Dawley (SD) rats were divided into the Sham group, hypoxic-ischemic (HI) group, and hypoxia (H) group. Rats in the HI group and H group were subjected to hypoxia-1 hour (h), 1.5 h and 2.5 h, respectively. Evaluation on brain lesion was made based on Zea-Longa scores, hematoxylin-eosin (HE) staining and Nissl staining. The brain infarction and blood vessels of rats were monitored and analyzed under TCD. Correlation analysis was applied to reveal the connection between hypoxic duration and infarct size detected by TCD or Nissl staining. RESULTS In H and HI modeling, longer duration of hypoxia was associated with higher Zea-Longa scores and more severe nerve damage. On the 1 d after modeling, necrosis was found in SD rats' brain indicated by HE and Nissl staining, which was aggravated as hypoxic duration prolonged. Alteration of brain structures and blood vessels of SD rats was displayed in Sham, HI and H rats under TCD. TCD images for coronal section revealed that brain infarct was detected at the cortex and there was marked cerebrovascular back-flow of HI rats regardless of hypoxic duration. On the 7 d after modeling, similar infarct was detected under TCD at the cortex of HI rats in hypoxia-1 h, 1.5 h and 2.5 h groups, whereas the morphological changes were deteriorated with longer hypoxic time. Correlation analysis revealed positive correlation of hypoxic duration with infarct size detected by histological detection and TCD. CONCLUSIONS TCD dynamically monitored cerebral infarction after NHIE modeling, which will be potentially served as a useful auxiliary method for future animal experimental modeling evaluation in the case of less animal sacrifice.
Collapse
Affiliation(s)
- Rui-Fang Ma
- Department of Anesthesiology, Institute of Neurological Disease, National-Local Joint Engineering Research Center of Translational Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China; School of Basic Medical Sciences, Kunming Medical University, Kunming 650000, Yunnan, China
| | - Lu-Lu Xue
- State Key Laboratory of Biotherapy, Sichuan University, Chengdu 610041, Sichuan, China
| | - Jin-Xiang Liu
- School of Basic Medical Sciences, Kunming Medical University, Kunming 650000, Yunnan, China
| | - Li Chen
- Department of Anesthesiology, Institute of Neurological Disease, National-Local Joint Engineering Research Center of Translational Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| | - Liu-Lin Xiong
- Department of Anesthesiology, Affiliated Hospital of Zunyi Medical University, Zunyi 563000, Guizhou, China.
| | - Ting-Hua Wang
- Department of Anesthesiology, Institute of Neurological Disease, National-Local Joint Engineering Research Center of Translational Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China; School of Basic Medical Sciences, Kunming Medical University, Kunming 650000, Yunnan, China.
| | - Fei Liu
- Department of Anesthesiology, Institute of Neurological Disease, National-Local Joint Engineering Research Center of Translational Medicine, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China
| |
Collapse
|
7
|
Barmin RA, Moosavifar M, Dasgupta A, Herrmann A, Kiessling F, Pallares RM, Lammers T. Polymeric materials for ultrasound imaging and therapy. Chem Sci 2023; 14:11941-11954. [PMID: 37969594 PMCID: PMC10631124 DOI: 10.1039/d3sc04339h] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 10/11/2023] [Indexed: 11/17/2023] Open
Abstract
Ultrasound (US) is routinely used for diagnostic imaging and increasingly employed for therapeutic applications. Materials that act as cavitation nuclei can improve the resolution of US imaging, and facilitate therapeutic US procedures by promoting local drug delivery or allowing temporary biological barrier opening at moderate acoustic powers. Polymeric materials offer a high degree of control over physicochemical features concerning responsiveness to US, e.g. via tuning chain composition, length and rigidity. This level of control cannot be achieved by materials made of lipids or proteins. In this perspective, we present key engineered polymeric materials that respond to US, including microbubbles, gas-stabilizing nanocups, microcapsules and gas-releasing nanoparticles, and discuss their formulation aspects as well as their principles of US responsiveness. Focusing on microbubbles as the most common US-responsive polymeric materials, we further evaluate the available chemical toolbox to engineer polymer shell properties and enhance their performance in US imaging and US-mediated drug delivery. Additionally, we summarize emerging applications of polymeric microbubbles in molecular imaging, sonopermeation, and gas and drug delivery, based on refinement of MB shell properties. Altogether, this manuscript provides new perspectives on US-responsive polymeric designs, envisaging their current and future applications in US imaging and therapy.
Collapse
Affiliation(s)
- Roman A Barmin
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital Aachen 52074 Germany
| | - MirJavad Moosavifar
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital Aachen 52074 Germany
| | - Anshuman Dasgupta
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital Aachen 52074 Germany
| | - Andreas Herrmann
- DWI - Leibniz Institute for Interactive Materials Aachen 52074 Germany
- Institute of Technical and Macromolecular Chemistry, RWTH Aachen University Aachen 52074 Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital Aachen 52074 Germany
| | - Roger M Pallares
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital Aachen 52074 Germany
| | - Twan Lammers
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital Aachen 52074 Germany
| |
Collapse
|
8
|
Parvathy G, Nazir A, Morani Z, Nazir A. Unveiling the power of imaging techniques: comparing high-resolution ultrasound and functional MR neurography in peripheral nervous system pathology: a short communication. Ann Med Surg (Lond) 2023; 85:5834-5837. [PMID: 37915668 PMCID: PMC10617846 DOI: 10.1097/ms9.0000000000001368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Accepted: 09/20/2023] [Indexed: 11/03/2023] Open
Abstract
MRI and ultrasonography are used for diagnosing and helping manage peripheral nervous system pathologies. Multiple studies have compared the diagnostic accuracy of these two modalities, but the results can vary depending on the specific conditions being evaluated. In general, high-resolution ultrasound is considered a reliable and accurate tool for evaluating peripheral nerves, with high sensitivity and specificity. High-resolution ultrasound and functional MR neurography are both noninvasive imaging techniques used to evaluate nerve structures in the body. However, they differ in several technical aspects like imaging modality, spatial resolution, field of view, image quality, and accessibility. Establishing consensus on image acquisition techniques, and reporting formats to facilitate effective communication and comparison of results will further enhance the outcomes. The use of advanced ultrasound techniques, such as contrast-enhanced ultrasound, elastography, and ultrasound biomicroscopy, should be promoted for better visualization and characterization of nervous tissues, like transcranial Doppler for cerebrovascular evaluation.
Collapse
Affiliation(s)
- Gauri Parvathy
- Oli Health Magazine Organization, Research, and Education, Kigali, Rwanda
- Department of Medicine, Tbilisi State Medical University, Tbilisi, Georgia
| | - Abubakar Nazir
- Oli Health Magazine Organization, Research, and Education, Kigali, Rwanda
- Department of Medicine, King Edward Medical University, Lahore, Pakistan
| | - Zoya Morani
- Washington University of Health and Science ,San Pedro, Belize
| | - Awais Nazir
- Oli Health Magazine Organization, Research, and Education, Kigali, Rwanda
- Department of Medicine, King Edward Medical University, Lahore, Pakistan
| |
Collapse
|
9
|
Pineda C, Sandoval H. Tracing our roots: on the relevance of rheumatology history. Clin Rheumatol 2023; 42:2929-2930. [PMID: 37672193 DOI: 10.1007/s10067-023-06640-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/11/2023] [Accepted: 05/15/2023] [Indexed: 09/07/2023]
Affiliation(s)
- Carlos Pineda
- National Institute of Rehabilitation Luis Guillermo Ibarra Ibarra, Calzada México- Xochimilco 289, Arenal de Guadalupe, Ciudad de México, 14389, México
| | - Hugo Sandoval
- National Institute of Rehabilitation Luis Guillermo Ibarra Ibarra, Calzada México- Xochimilco 289, Arenal de Guadalupe, Ciudad de México, 14389, México.
| |
Collapse
|
10
|
Liu T, Shi J, Fu Y, Zhang Y, Bai Y, He S, Deng W, Jin Q, Chen Y, Fang L, He L, Li Y, Yang Y, Zhang L, Lv Q, Wang J, Xie M. New trends in non-pharmacological approaches for cardiovascular disease: Therapeutic ultrasound. Trends Cardiovasc Med 2023; 33:431-440. [PMID: 35461990 DOI: 10.1016/j.tcm.2022.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Revised: 04/05/2022] [Accepted: 04/19/2022] [Indexed: 11/30/2022]
Abstract
Significant advances in application of therapeutic ultrasound have been reported in the past decades. Therapeutic ultrasound is an emerging non-invasive stimulation technique. This approach has shown high potential for treatment of various disease including cardiovascular disease. In this review, application principle and significance of the basic parameters of therapeutic ultrasound are summarized. The effects of therapeutic ultrasound in myocardial ischemia, heart failure, myocarditis, arrhythmias, and hypertension are explored, with key focus on the underlying mechanism. Further, the limitations and challenges of ultrasound therapy on clinical translation are evaluated to promote application of the novel strategy in cardiovascular diseases.
Collapse
Affiliation(s)
- Tianshu Liu
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Jiawei Shi
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Yanan Fu
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Yichan Zhang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Ying Bai
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Shukun He
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Wenhui Deng
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Qiaofeng Jin
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Yihan Chen
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Lingyun Fang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Lin He
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Yuman Li
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Yali Yang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Li Zhang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Qing Lv
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Jing Wang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
| | - Mingxing Xie
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China; Hubei Province Clinical Research Center for Medical Imaging, Wuhan 430022, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China.
| |
Collapse
|
11
|
Vomer RP, Boggess S, Boggess B. Ultrasound Evaluation of Knee Osteoarthritis. Cureus 2023; 15:e39188. [PMID: 37378133 PMCID: PMC10292167 DOI: 10.7759/cureus.39188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/18/2023] [Indexed: 06/29/2023] Open
Abstract
While radiographs and magnetic resonance imaging (MRI) have long been used in the assessment of osteoarthritis (OA), ultrasound imaging has been rapidly accepted by musculoskeletal providers in both the assessment and treatment of OA. A limiting factor in the use of ultrasound is the proper training required by the user for results to be reliable and reproducible. A standardized ultrasound protocol can potentially address this limiting factor. The critical information to consider in a standardized protocol include proper patient positioning, probe alignment, probe orientation, and identification of the appropriate anatomic landmarks. The outlined protocol considers these factors with the purpose of providing a step-by-step method to assess and monitor knee OA.
Collapse
Affiliation(s)
- Rock P Vomer
- Department of Family and Community Health/Department of Orthopedics, Division of Sports Medicine, Duke University, Durham, USA
- Family Medicine, Mayo Clinic Jacksonville Campus, Jacksonville, USA
| | - Samuel Boggess
- Department of Osteopathic Medicine, Philadelphia College of Osteopathic Medicine-Georgia, Suwanee, USA
| | - Blake Boggess
- Department of Orthopedics, Division of Sports Medicine, Duke University, Durham, USA
| |
Collapse
|
12
|
Hafid A, Difallah S, Alves C, Abdullah S, Folke M, Lindén M, Kristoffersson A. State of the Art of Non-Invasive Technologies for Bladder Monitoring: A Scoping Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:2758. [PMID: 36904965 PMCID: PMC10007578 DOI: 10.3390/s23052758] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 02/02/2023] [Accepted: 02/28/2023] [Indexed: 06/18/2023]
Abstract
Bladder monitoring, including urinary incontinence management and bladder urinary volume monitoring, is a vital part of urological care. Urinary incontinence is a common medical condition affecting the quality of life of more than 420 million people worldwide, and bladder urinary volume is an important indicator to evaluate the function and health of the bladder. Previous studies on non-invasive techniques for urinary incontinence management technology, bladder activity and bladder urine volume monitoring have been conducted. This scoping review outlines the prevalence of bladder monitoring with a focus on recent developments in smart incontinence care wearable devices and the latest technologies for non-invasive bladder urine volume monitoring using ultrasound, optical and electrical bioimpedance techniques. The results found are promising and their application will improve the well-being of the population suffering from neurogenic dysfunction of the bladder and the management of urinary incontinence. The latest research advances in bladder urinary volume monitoring and urinary incontinence management have significantly improved existing market products and solutions and will enable the development of more effective future solutions.
Collapse
Affiliation(s)
- Abdelakram Hafid
- School of Innovation, Design and Engineering, Mälardalen University, P.O. Box 883, 721 23 Västerås, Sweden
- Textile Materials Technology, Department of Textile Technology, Faculty of Textiles, Engineering and Business Swedish School of Textiles, University of Borås, 501 90 Borås, Sweden
| | - Sabrina Difallah
- Laboratory of Instrumentation, University of Sciences and Technology Houari Boumediene, 16111 Algiers, Algeria
| | - Camille Alves
- Assistive Technology Lab (NTA), Faculty of Electrical Engineering, Federal University of Uberlandia, Uberlandia 38408-100, Brazil
- Laboratoire de Conception, d’Optimisation et de Modélisation des Systèmes (LCOMS), Université de Lorraine, 57000 Metz, France
| | - Saad Abdullah
- School of Innovation, Design and Engineering, Mälardalen University, P.O. Box 883, 721 23 Västerås, Sweden
| | - Mia Folke
- School of Innovation, Design and Engineering, Mälardalen University, P.O. Box 883, 721 23 Västerås, Sweden
| | - Maria Lindén
- School of Innovation, Design and Engineering, Mälardalen University, P.O. Box 883, 721 23 Västerås, Sweden
| | - Annica Kristoffersson
- School of Innovation, Design and Engineering, Mälardalen University, P.O. Box 883, 721 23 Västerås, Sweden
| |
Collapse
|
13
|
Brost EE, Stish BJ, Lee CU, Urban MW, Deufel CL. Improving ultrasound-based brachytherapy needle conspicuity by applying an echogenic coating. Med Phys 2023; 50:1418-1427. [PMID: 36511174 DOI: 10.1002/mp.16138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 11/08/2022] [Accepted: 11/08/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Applicator conspicuity in ultrasound-guided brachytherapy procedures is commonly impaired by imaging artifacts or non-ideal imaging geometry, which can slow down applicator position digitization and increase the geometric uncertainty of the delivered dose distribution. PURPOSE The purpose of this study was to improve the conspicuity of high-dose rate (HDR) brachytherapy needles under B-mode ultrasound imaging by applying an echogenic surface coating. Our hypothesis was that an echogenic coating would reduce artifacts and improve needle visualization within regions of signal degradation. METHODS In this study, 17-gauge, 25-cm long titanium HDR brachytherapy needles were coated with acoustically reflective microspheres over a 2.5 cm region starting from the needle tip. Three coating thicknesses (27 μm, 40 μm, 64 μm) were compared against an uncoated control needle. The coated and uncoated needles were imaged using B-mode ultrasound in a tissue-equivalent prostate phantom and in a cadaverous male pelvis using a transrectal probe. Needle conspicuity was assessed under multiple conditions: a single needle implant, an implant with multiple needles between the probe and the needle of interest, and an angled needle implant. All images were assessed qualitatively for needle conspicuity and the presence of artifacts and quantitatively using grey-scale image intensity values. RESULTS The 64 μm echogenic coating reduced the magnitude of reverberation artifacts by 31 ± 14% and comet tail artifacts by 40%-70%. The echogenic coating also improved needle contrast, measured by the relative differences in signal intensity compared with the adjacent environment, when needles were angled up to 30° with respect to the transducer probe in the cadaver. The improvements in conspicuity and artifact reduction increased with increasing coating thickness. The performance of the needles coated with the 64 μm thickness was qualitatively superior and yielded high-contrast, well-circumscribed signals in the cadaverous male pelvis, even under situations where a needle was acoustically shadowed by multiple other needles. CONCLUSIONS An echogenic surface coating reduced imaging artifacts and improved needle conspicuity under realistic clinical conditions for ultrasound-based prostate or gynecological brachytherapy. The improved conspicuity has the potential to improve the efficiency of needle placement and the accuracy of needle position digitization during brachytherapy procedures.
Collapse
Affiliation(s)
- Eric E Brost
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Bradley J Stish
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA
| | - Christine U Lee
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Matthew W Urban
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | |
Collapse
|
14
|
Alfuraih AM, Alqarni MA, Alhuthaili HS, Mubaraki MY, Alotaibi NN, Almusalim FM. Reproducibility and feasibility of a handheld ultrasound device compared to a standard ultrasound machine in muscle thickness measurements. Australas J Ultrasound Med 2023; 26:13-20. [PMID: 36960135 PMCID: PMC10030094 DOI: 10.1002/ajum.12333] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Objective To test the feasibility and reproducibility of a handheld ultrasound device (HUD) compared to a standard ultrasound machine for muscle thickness measurements in healthy participants. Methods A prospective cross-sectional study was designed where two novice operators tested the thickness of the vastus lateralis, rectus femoris, and vastus intermedius muscles on recruited asymptomatic participants with no history of muscle diseases. The anterior-posterior thickness of each muscle was measured three times per operator to evaluate intra-operator reproducibility and using two machines to evaluate inter-system reproducibility. Scanning started using the HUD followed by the standard system. Intraclass correlation coefficients (ICC) and simple linear regression were used to test for reproducibility and proportional bias respectively. Results A total of 33 male participants volunteered to take part in this study with a mean age of 22.7 years (6.8). Intra-operator reproducibility was almost perfect for both operators on both machines (ICC > 0.80). The measurements difference percentage between the machines ranged from 1.8% to 6.6% and inter-system reproducibility ICC ranged from 0.815 to 0.927 showing excellent reproducibility. Inter-operator reproducibility was poor to moderate on both machines (ICC: 0.522-0.849). Regression analysis showed no proportional bias in the measurements. All measurements were completed successfully using the HUD. Conclusion The HUD demonstrated excellent accuracy compared to the standard ultrasound machine for measuring thigh muscle thickness.
Collapse
Affiliation(s)
- Abdulrahman M. Alfuraih
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Mohammed A. Alqarni
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Hamad S. Alhuthaili
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Meshal Y. Mubaraki
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Nader N. Alotaibi
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| | - Fahad M. Almusalim
- Radiology and Medical Imaging DepartmentCollege of Applied Medical Sciences, Prince Sattam bin Abdulaziz UniversityKharjSaudi Arabia
| |
Collapse
|
15
|
Liu R, Xu Y, Qu S, Dai Z. Major Strategies for Spatial Control of Ultrasound-Driven Gene Expression to Enhance Therapeutic Specificity. Crit Rev Biomed Eng 2023; 51:29-40. [PMID: 37522539 DOI: 10.1615/critrevbiomedeng.2023047680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
A major challenge of gene therapy is to achieve highly specific transgene expression in tissues of interest with minimized off-target expression. Ultrasound in combination with microbubbles can transiently increase permeability of desired cells or tissues and thereby facilitate gene transfer. This kind of ultrasound-driven transgene expression has gained increasing attention due to its deep tissue penetration and high spatiotemporal resolution. However, successful genetic manipulation in vivo with ultrasound need to well optimize various aspects involved in this process. Ultrasound parameters, microbubble dose, and gene vectors need to be optimized for highly increased transgene expression in the cells of interest. Conversely, the potential off-target transgene expression and toxicities need to be reduced by modification of gene vectors and/or promoter sequence. This review will discuss some major strategies for enhanced specificity of the ultrasound-mediated gene transfer in vivo. Five major strategies will be discussed, including the integration of real-time imaging methods, local injection, targeted microbubbles loaded with nucleic acids, stealth nanocarriers, and cell-specific promoter. The advantages and limitations of each strategy were outlined, hoping to provide a guideline for researchers in achieving high specific ultrasound-driven gene expression.
Collapse
Affiliation(s)
- Renfa Liu
- Department of Biomedical Engineering, College of Future Technology, National Biomedical Imaging Center, Peking University, China
| | - Yunxue Xu
- Department of Biomedical Engineering, College of Future Technology, National Biomedical Imaging Center, Peking University, China
| | - Shuai Qu
- Department of Biomedical Engineering, College of Future Technology, National Biomedical Imaging Center, Peking University, China
| | - Zhifei Dai
- Department of Biomedical Engineering, College of Future Technology, National Biomedical Imaging Center, Peking University, China
| |
Collapse
|
16
|
Ultrasound Radiomics for the Detection of Early-Stage Liver Fibrosis. Diagnostics (Basel) 2022; 12:diagnostics12112737. [PMID: 36359580 PMCID: PMC9689042 DOI: 10.3390/diagnostics12112737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 11/06/2022] [Accepted: 11/07/2022] [Indexed: 11/10/2022] Open
Abstract
Objective: The study evaluates quantitative ultrasound (QUS) texture features with machine learning (ML) to enhance the sensitivity of B-mode ultrasound (US) for the detection of fibrosis at an early stage and distinguish it from advanced fibrosis. Different ML methods were evaluated to determine the best diagnostic model. Methods: 233 B-mode images of liver lobes with early and advanced-stage fibrosis induced in a rat model were analyzed. Sixteen features describing liver texture were measured from regions of interest (ROIs) drawn on B-mode images. The texture features included a first-order statistics run length (RL) and gray-level co-occurrence matrix (GLCM). The features discriminating between early and advanced fibrosis were used to build diagnostic models with logistic regression (LR), naïve Bayes (nB), and multi-class perceptron (MLP). The diagnostic performances of the models were compared by ROC analysis using different train-test sampling approaches, including leave-one-out, 10-fold cross-validation, and varying percentage splits. METAVIR scoring was used for histological fibrosis staging of the liver. Results: 15 features showed a significant difference between the advanced and early liver fibrosis groups, p < 0.05. Among the individual features, first-order statics features led to the best classification with a sensitivity of 82.1−90.5% and a specificity of 87.1−89.8%. For the features combined, the diagnostic performances of nB and MLP were high, with the area under the ROC curve (AUC) approaching 0.95−0.96. LR also yielded high diagnostic performance (AUC = 0.91−0.92) but was lower than nB and MLP. The diagnostic variability between test-train trials, measured by the coefficient-of-variation (CV), was higher for LR (3−5%) than nB and MLP (1−2%). Conclusion: Quantitative ultrasound with machine learning differentiated early and advanced fibrosis. Ultrasound B-mode images contain a high level of information to enable accurate diagnosis with relatively straightforward machine learning methods like naïve Bayes and logistic regression. Implementing simple ML approaches with QUS features in clinical settings could reduce the user-dependent limitation of ultrasound in detecting early-stage liver fibrosis.
Collapse
|
17
|
Kehrer A, Ruewe M, Platz Batista da Silva N, Lonic D, Heidekrueger PI, Knoedler S, Jung EM, Prantl L, Knoedler L. Using High-Resolution Ultrasound to Assess Post-Facial Paralysis Synkinesis—Machine Settings and Technical Aspects for Facial Surgeons. Diagnostics (Basel) 2022; 12:diagnostics12071650. [PMID: 35885554 PMCID: PMC9322000 DOI: 10.3390/diagnostics12071650] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 07/05/2022] [Indexed: 12/27/2022] Open
Abstract
Background: Synkinesis of the facial musculature is a detrimental sequalae in post-paralytic facial palsy (PPFP) patients. Detailed knowledge on the technical requirements and device properties in a high-resolution ultrasound (HRUS) examination is mandatory for a reliable facial muscle assessment in PPFP patients. We therefore aimed to outline the key steps in a HRUS examination and extract an optimized workflow schema. Methods: From December 2020 to April 2021, 20 patients with unilateral synkinesis underwent HRUS. All HRUS examinations were performed by the first author using US devices with linear multifrequency transducers of 4–18 MHz, including a LOGIQ E9 and a LOGIQ S7 XDclear (GE Healthcare; Milwaukee, WI, USA), as well as Philips Affinity 50G (Philips Health Systems; Eindhoven, the Netherlands). Results: Higher-frequency and multifrequency linear probes ≥15 MHz provided superior imaging qualities. The selection of the preset program Small Parts, Breast or Thyroid was linked with a more detailed contrast of the imaging morphology of facial tissue layers. Frequency (Frq) = 15 MHz, Gain (Gn) = 25–35 db, Depth (D) = 1–1.5 cm, and Focus (F) = 0.5 cm enhanced the image quality and assessability. Conclusions: An optimized HRUS examination protocol for quantitative and qualitative facial muscle assessments was proposed.
Collapse
Affiliation(s)
- Andreas Kehrer
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (M.R.); (D.L.); (P.I.H.); (L.P.); (L.K.)
- Correspondence: ; Tel.: +49-941-944-6763
| | - Marc Ruewe
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (M.R.); (D.L.); (P.I.H.); (L.P.); (L.K.)
| | | | - Daniel Lonic
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (M.R.); (D.L.); (P.I.H.); (L.P.); (L.K.)
| | - Paul Immanuel Heidekrueger
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (M.R.); (D.L.); (P.I.H.); (L.P.); (L.K.)
| | - Samuel Knoedler
- Department of Plastic Surgery and Hand Surgery, Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany;
| | - Ernst Michael Jung
- Department of Radiology, University Hospital Regensburg, 93053 Regensburg, Germany; (N.P.B.d.S.); (E.M.J.)
| | - Lukas Prantl
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (M.R.); (D.L.); (P.I.H.); (L.P.); (L.K.)
| | - Leonard Knoedler
- Department of Plastic, Hand and Reconstructive Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (M.R.); (D.L.); (P.I.H.); (L.P.); (L.K.)
| |
Collapse
|
18
|
Yang CD, Jessen J, Lin KY. Ultrasound-assisted ocular drug delivery: A review of current evidence. JOURNAL OF CLINICAL ULTRASOUND : JCU 2022; 50:685-693. [PMID: 35474512 DOI: 10.1002/jcu.23214] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 04/11/2022] [Accepted: 04/15/2022] [Indexed: 06/14/2023]
Abstract
Efficient ocular drug delivery is a challenging clinical problem with various therapeutic options but no clearly preferred methodology. Given the ubiquity of ultrasound as a diagnostic technique, the safety profile of ultrasound in an ocular context, and the prospect of custom-made ultrasound-sensitive contrast agents, ultrasound presents an attractive ocular drug delivery modality. In this review, we evaluate our present understanding of ultrasound as it relates to ocular drug delivery and significant knowledge gaps in the field. In doing so, we hope to call attention to a potentially novel drug delivery pathway that could be manipulated to treat or cure ocular diseases.
Collapse
Affiliation(s)
- Christopher D Yang
- Department of Ophthalmology, University of California, Irvine School of Medicine, Irvine, California, USA
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, California, USA
| | - Jordan Jessen
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, California, USA
| | - Ken Y Lin
- Department of Ophthalmology, University of California, Irvine School of Medicine, Irvine, California, USA
- Gavin Herbert Eye Institute, University of California, Irvine, Irvine, California, USA
- Department of Biomedical Engineering, University of California, Irvine, California, USA
| |
Collapse
|
19
|
Wang P, Tian M, Ren W. Correlation Between Contrast-Enhanced Ultrasound and Immune Response of Distant Hepatocellular Carcinoma After Radiofrequency Ablation in a Murine Model. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2022; 41:713-723. [PMID: 34018628 DOI: 10.1002/jum.15753] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Revised: 04/27/2021] [Accepted: 05/06/2021] [Indexed: 06/12/2023]
Abstract
OBJECTIVES To investigate the relationships between contrast-enhanced ultrasound (CEUS) and the immune status of a distant tumor after radiofrequency ablation (RFA) in a mouse model of hepatocellular carcinoma (HCC). METHODS Twenty-four mice with two liver tumors were randomized into two groups. RFA was performed on the left tumor in the RFA group. Growth of the right tumors in both groups was monitored after RFA. According to tumor growth, two time points at which tumor growth was halted and restored were selected for study. Then, another 24 mice were randomized into RFA and non-RFA groups. The CEUS parameters, apoptosis, CD8+ T cell, and vasculogenic mimicry (VM) of the right tumors were analyzed on the two aforementioned time points in each group. RESULTS Days 3 and 6 were selected as the time points of tumor retardation and progressive growth, respectively. The different immune status of the distant tumors at the two time points after RFA was confirmed by CD8+ T cell and apoptosis (both P < 0.001). Peak intensity, time to peak, area wash-in, and area wash-out of the CEUS parameters increased significantly in the day-6 RFA group versus the day-3 RFA group (P < .001, P = .017, P = .005, P = .002, respectively). VM of the day-6 RFA group was higher than that of the day-3 RFA group (P = .003). CONCLUSIONS CEUS maybe a good method to follow the immune response after RFA in an advanced HCC mouse model.
Collapse
Affiliation(s)
- Peng Wang
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| | - Mi Tian
- Department of Nephrology, Shengjing Hospital of China Medical University, Shenyang, China
| | - Weidong Ren
- Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China
| |
Collapse
|
20
|
Chu J, Zhang Y, Zhang W, Zhao D, Xu J, Yu T, Yang G. The value of multimodal ultrasonography in differential diagnosis of tuberculous and non-tuberculous superficial lymphadenitis. BMC Surg 2021; 21:416. [PMID: 34906107 PMCID: PMC8670034 DOI: 10.1186/s12893-021-01418-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 12/01/2021] [Indexed: 12/21/2022] Open
Abstract
Background To investigate the value of multimodal ultrasonography in differentiating tuberculosis from other lymphadenopathy. Methods Sixty consecutive patients with superficial lymphadenopathy treated at our hospital from January 2017 to December 2018 were categorized into four types based on the color Doppler ultrasound, five types based on contrast-enhanced ultrasound, and five types based on elastography. Sensitivity and specificity were calculated of all the three imaging, including color Doppler examination, contrast-enhanced ultrasound and one individual multimodal method, for detecting lymph nodes. Results A total of 60 patients were included in the final analysis. Of those, Mycobacterium tuberculosis was positive in 38 patients and negative in 22 patients. Among the 38 patients who were positive for Mycobacterium tuberculosis, of which 23 had a history of pulmonary tuberculosis, accounting for 60.53% of the positive cases, and the remaining patients did not combine lesions of other organs. Among the 60 superficial lymph nodes, 63.3% presented with tuberculous lymphadenitis. The sensitivity, specificity, and accuracy of the color Doppler examination were 73.68%, 68.18%, and 71.67%, respectively. The sensitivity, specificity and accuracy of contrast-enhanced ultrasound were 89.47%, 63.64% and 80.00%, respectively. The sensitivity, specificity and accuracy of the elastography were 63.16%, 63.64% and 63.33%, respectively. The sensitivity, specificity and accuracy of one individual multimodal method were 42.11%, 95.45% and 61.67%, respectively. The sensitivity, specificity and accuracy of all modes combined were 100.00%, 27.27% and 73.33%, respectively. Conclusion Multimodal ultrasonography has high predictive value for the differential diagnosis of superficial tuberculous lymphadenitis.
Collapse
Affiliation(s)
- Jie Chu
- Department of Ultrasound, Zhejiang Hospital of Integrated Traditional Chinese and Western Medicine, 208 Huancheng East Road, Downtown District, Hangzhou, 310003, Zhejiang, China
| | - Ying Zhang
- Department of Ultrasound, Zhejiang Hospital of Integrated Traditional Chinese and Western Medicine, 208 Huancheng East Road, Downtown District, Hangzhou, 310003, Zhejiang, China
| | - Wenzhi Zhang
- Department of Ultrasound, Zhejiang Hospital of Integrated Traditional Chinese and Western Medicine, 208 Huancheng East Road, Downtown District, Hangzhou, 310003, Zhejiang, China
| | - Dan Zhao
- Department of Ultrasound, Zhejiang Hospital of Integrated Traditional Chinese and Western Medicine, 208 Huancheng East Road, Downtown District, Hangzhou, 310003, Zhejiang, China
| | - Jianping Xu
- Department of Ultrasound, Zhejiang Hospital of Integrated Traditional Chinese and Western Medicine, 208 Huancheng East Road, Downtown District, Hangzhou, 310003, Zhejiang, China
| | - Tianzhuo Yu
- Department of Ultrasound, Zhejiang Hospital of Integrated Traditional Chinese and Western Medicine, 208 Huancheng East Road, Downtown District, Hangzhou, 310003, Zhejiang, China
| | - Gaoyi Yang
- Department of Ultrasound, Zhejiang Hospital of Integrated Traditional Chinese and Western Medicine, 208 Huancheng East Road, Downtown District, Hangzhou, 310003, Zhejiang, China.
| |
Collapse
|
21
|
Sabuncu S, Yildirim A. Gas-stabilizing nanoparticles for ultrasound imaging and therapy of cancer. NANO CONVERGENCE 2021; 8:39. [PMID: 34851458 PMCID: PMC8636532 DOI: 10.1186/s40580-021-00287-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 11/05/2021] [Indexed: 05/06/2023]
Abstract
The use of ultrasound in the clinic has been long established for cancer detection and image-guided tissue biopsies. In addition, ultrasound-based methods have been widely explored to develop more effective cancer therapies such as localized drug delivery, sonodynamic therapy, and focused ultrasound surgery. Stabilized fluorocarbon microbubbles have been in use as contrast agents for ultrasound imaging in the clinic for several decades. It is also known that microbubble cavitation could generate thermal, mechanical, and chemical effects in the tissue to improve ultrasound-based therapies. However, the large size, poor stability, and short-term cavitation activity of microbubbles limit their applications in cancer imaging and therapy. This review will focus on an alternative type of ultrasound responsive material; gas-stabilizing nanoparticles, which can address the limitations of microbubbles with their nanoscale size, robustness, and high cavitation activity. This review will be of interest to researchers who wish to explore new agents to develop improved methods for molecular ultrasound imaging and therapy of cancer.
Collapse
Affiliation(s)
- Sinan Sabuncu
- CEDAR, Knight Cancer Institute, School of Medicine, Oregon Health & Science University, Portland, OR, 97201, USA
| | - Adem Yildirim
- CEDAR, Knight Cancer Institute, School of Medicine, Oregon Health & Science University, Portland, OR, 97201, USA.
| |
Collapse
|
22
|
Sidi M, Sani GM, Ya’u A, Zira JD, Loshugno SS, Luntsi G. The current status of ultrasound practice in Kano metropolis, Nigeria. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [DOI: 10.1186/s43055-021-00509-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Abstract
Background
Ultrasound has been in clinical use to image the human body for over half a century. An audit should be performed on professional practice aimed at taking corrective measures where errors are identified and improvement in the practice when errors are not detected. This study is aimed at evaluating the current status of ultrasound practice in Kano metropolis, Nigeria.
Results
Out of the 70 (100%) administered questionnaires, 68 (97.14%) were returned, and 64 (91.43%) were properly filled. Fifty-eight (90.6%) knew the exact meaning of ultrasound, and 34 (53%) considered ultrasound as a modality of choice for imaging and diagnosis of abdominal masses. None of the participants was exposed to advanced ultrasound technology. Only 3 (4.7%) and 5 (7.8%) of the respondents performed infection control, air reverberation pattern and electronic noise checks.
Conclusion
Ultrasound practitioners demonstrate good knowledge of ultrasound and its application. However, there was unavailability of advanced ultrasound equipment. There was also poor understanding and practice of quality assurance among practitioners. Ultrasound equipment might have been grossly underutilized and qualities of images produced by the equipment are not certain were optimal.
Collapse
|
23
|
Byrne J, Huang HW, McRae JC, Babaee S, Soltani A, Becker SL, Traverso G. Devices for drug delivery in the gastrointestinal tract: A review of systems physically interacting with the mucosa for enhanced delivery. Adv Drug Deliv Rev 2021; 177:113926. [PMID: 34403749 DOI: 10.1016/j.addr.2021.113926] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 07/14/2021] [Accepted: 08/09/2021] [Indexed: 12/14/2022]
Abstract
The delivery of macromolecules via the gastrointestinal (GI) tract remains a significant challenge. A variety of technologies using physical modes of drug delivery have been developed and investigated to overcome the epithelial cell layer of the GI tract for local and systemic delivery. These technologies include direct injection, jetting, ultrasound, and iontophoresis, which have been largely adapted from transdermal drug delivery. Direct injection of agents using needles through endoscopy has been used clinically for over a century. Jetting, a needle-less method of drug delivery where a high-speed stream of fluid medication penetrates tissue, has been evaluated pre-clinically for delivery of agents into the buccal mucosa. Ultrasound has been shown to be beneficial in enhancing delivery of macromolecules, including nucleic acids, in pre-clinical animal models. The application of an electric field gradient to drive drugs into tissues through the technique of iontophoresis has been shown to deliver highly toxic chemotherapies into GI tissues. Here in, we provide an in-depth overview of these physical modes of drug delivery in the GI tract and their clinical and preclinical uses.
Collapse
Affiliation(s)
- James Byrne
- Division of Gastroenterology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02142, USA; Harvard Radiation Oncology Program, Boston, MA 02114, USA; Department of Radiation Oncology, University of Iowa, Iowa City, IA 52242, USA; Department of Biomedical Engineering, University of Iowa, Iowa City, IA 52240, USA
| | - Hen-Wei Huang
- Division of Gastroenterology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02142, USA
| | - James C McRae
- Division of Gastroenterology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Sahab Babaee
- Division of Gastroenterology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02142, USA
| | - Amin Soltani
- Division of Gastroenterology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Sarah L Becker
- Division of Gastroenterology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Giovanni Traverso
- Division of Gastroenterology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| |
Collapse
|
24
|
Zhang D, Jiang F, Yin R, Wu GG, Wei Q, Cui XW, Zeng SE, Ni XJ, Dietrich CF. A Review of the Role of the S-Detect Computer-Aided Diagnostic Ultrasound System in the Evaluation of Benign and Malignant Breast and Thyroid Masses. Med Sci Monit 2021; 27:e931957. [PMID: 34552043 PMCID: PMC8477643 DOI: 10.12659/msm.931957] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Accepted: 06/10/2021] [Indexed: 12/24/2022] Open
Abstract
Computer-aided diagnosis (CAD) systems have attracted extensive attention owing to their performance in the field of image diagnosis and are rapidly becoming a promising auxiliary tool in medical imaging tasks. These systems can quantitatively evaluate complex medical imaging features and achieve efficient and high-diagnostic accuracy. Deep learning is a representation learning method. As a major branch of artificial intelligence technology, it can directly process original image data by simulating the structure of the human brain neural network, thus independently completing the task of image recognition. S-Detect is a novel and interactive CAD system based on a deep learning algorithm, which has been integrated into ultrasound equipment and can help radiologists identify benign and malignant nodules, reduce physician workload, and optimize the ultrasound clinical workflow. S-Detect is becoming one of the most commonly used CAD systems for ultrasound evaluation of breast and thyroid nodules. In this review, we describe the S-Detect workflow and outline its application in breast and thyroid nodule detection. Finally, we discuss the difficulties and challenges faced by S-Detect as a precision medical tool in clinical practice and its prospects.
Collapse
Affiliation(s)
- Di Zhang
- Department of Medical Ultrasound, Affiliated Hospital of Nantong University, Nantong, Jiangsu, PR China
| | - Fan Jiang
- Department of Medical Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, PR China
| | - Rui Yin
- Department of Ultrasound, Affiliated Renhe Hospital of China Three Gorges University, Yichang, Hubei, PR China
| | - Ge-Ge Wu
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Qi Wei
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Shu-E Zeng
- Department of Ultrasound, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Xue-Jun Ni
- Department of Medical Ultrasound, Affiliated Hospital of Nantong University, Nantong, Jiangsu, PR China
| | | |
Collapse
|
25
|
Schmidbauer VU, Dovjak GO, Yildirim MS, Mayr-Geisl G, Weber M, Diogo MC, Gruber GM, Prayer F, Milos RI, Stuempflen M, Ulm B, Binder J, Bettelheim D, Kiss H, Prayer D, Kasprian G. Mapping Human Fetal Brain Maturation In Vivo Using Quantitative MRI. AJNR Am J Neuroradiol 2021; 42:2086-2093. [PMID: 34503947 DOI: 10.3174/ajnr.a7286] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Accepted: 07/19/2021] [Indexed: 01/16/2023]
Abstract
BACKGROUND AND PURPOSE On the basis of a single multidynamic multiecho sequence acquisition, SyMRI generates a variety of quantitative image data that can characterize tissue-specific properties. The aim of this retrospective study was to evaluate the feasibility of SyMRI for the qualitative and quantitative assessment of fetal brain maturation. MATERIALS AND METHODS In 52 fetuses, multidynamic multiecho sequence acquisitions were available. SyMRI was used to perform multidynamic multiecho-based postprocessing. Fetal brain maturity was scored qualitatively on the basis of SyMRI-generated MR imaging data. The results were compared with conventionally acquired T1-weighted/T2-weighted contrasts as a standard of reference. Myelin-related changes in T1-/T2-relaxation time/relaxation rate, proton density, and MR imaging signal intensity of the developing fetal brain stem were measured. A Pearson correlation analysis was used to detect correlations between the following: 1) the gestational age at MR imaging and the fetal brain maturity score, and 2) the gestational age at MR imaging and the quantitative measurements. RESULTS SyMRI provided images of sufficient quality in 12/52 (23.08%) (range, 23 + 6-34 + 0) fetal multidynamic multiecho sequence acquisitions. The fetal brain maturity score positively correlated with gestational age at MR imaging (SyMRI: r = 0.915, P < .001/standard of reference: r = 0.966, P < .001). Myelination-related changes in the T2 relaxation time/T2 relaxation rate of the medulla oblongata significantly correlated with gestational age at MR imaging (T2-relaxation time: r = -0.739, P = .006/T2-relaxation rate: r = 0.790, P = .002). CONCLUSIONS Fetal motion limits the applicability of multidynamic multiecho-based postprocessing. However, SyMRI-generated image data of sufficient quality enable the qualitative assessment of maturity-related changes of the fetal brain. In addition, quantitative T2 relaxation time/T2 relaxation rate mapping characterizes myelin-related changes of the brain stem prenatally. This approach, if successful, opens novel possibilities for the evaluation of structural and biochemical aspects of fetal brain maturation.
Collapse
Affiliation(s)
- V U Schmidbauer
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - G O Dovjak
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - M S Yildirim
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | | | - M Weber
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - M C Diogo
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - G M Gruber
- Department of Anatomy and Biomechanics (G.M.G.), Karl Landsteiner University of Health Sciences, Krems an der Donau, Austria
| | - F Prayer
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - R-I Milos
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - M Stuempflen
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - B Ulm
- Obstetrics and Gynecology (B.U., J.B., D.B., H.K.), Medical University of Vienna, Vienna, Austria
| | - J Binder
- Obstetrics and Gynecology (B.U., J.B., D.B., H.K.), Medical University of Vienna, Vienna, Austria
| | - D Bettelheim
- Obstetrics and Gynecology (B.U., J.B., D.B., H.K.), Medical University of Vienna, Vienna, Austria
| | - H Kiss
- Obstetrics and Gynecology (B.U., J.B., D.B., H.K.), Medical University of Vienna, Vienna, Austria
| | - D Prayer
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| | - G Kasprian
- From the Departments of Biomedical Imaging and Image-Guided Therapy (V.U.S., G.O.D., M.S.Y., M.W., M.C.D., F.P., R.-I.M., M.S., D.P. G.K)
| |
Collapse
|
26
|
Krafft MP, Riess JG. Therapeutic oxygen delivery by perfluorocarbon-based colloids. Adv Colloid Interface Sci 2021; 294:102407. [PMID: 34120037 DOI: 10.1016/j.cis.2021.102407] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 03/18/2021] [Accepted: 03/25/2021] [Indexed: 02/06/2023]
Abstract
After the protocol-related indecisive clinical trial of Oxygent, a perfluorooctylbromide/phospholipid nanoemulsion, in cardiac surgery, that often unduly assigned the observed untoward effects to the product, the development of perfluorocarbon (PFC)-based O2 nanoemulsions ("blood substitutes") has come to a low. Yet, significant further demonstrations of PFC O2-delivery efficacy have continuously been reported, such as relief of hypoxia after myocardial infarction or stroke; protection of vital organs during surgery; potentiation of O2-dependent cancer therapies, including radio-, photodynamic-, chemo- and immunotherapies; regeneration of damaged nerve, bone or cartilage; preservation of organ grafts destined for transplantation; and control of gas supply in tissue engineering and biotechnological productions. PFC colloids capable of augmenting O2 delivery include primarily injectable PFC nanoemulsions, microbubbles and phase-shift nanoemulsions. Careful selection of PFC and other colloid components is critical. The basics of O2 delivery by PFC nanoemulsions will be briefly reminded. Improved knowledge of O2 delivery mechanisms has been acquired. Advanced, size-adjustable O2-delivering nanoemulsions have been designed that have extended room-temperature shelf-stability. Alternate O2 delivery options are being investigated that rely on injectable PFC-stabilized microbubbles or phase-shift PFC nanoemulsions. The latter combine prolonged circulation in the vasculature, capacity for penetrating tumor tissues, and acute responsiveness to ultrasound and other external stimuli. Progress in microbubble and phase-shift emulsion engineering, control of phase-shift activation (vaporization), understanding and control of bubble/ultrasound/tissue interactions is discussed. Control of the phase-shift event and of microbubble size require utmost attention. Further PFC-based colloidal systems, including polymeric micelles, PFC-loaded organic or inorganic nanoparticles and scaffolds, have been devised that also carry substantial amounts of O2. Local, on-demand O2 delivery can be triggered by external stimuli, including focused ultrasound irradiation or tumor microenvironment. PFC colloid functionalization and targeting can help adjust their properties for specific indications, augment their efficacy, improve safety profiles, and expand the range of their indications. Many new medical and biotechnological applications involving fluorinated colloids are being assessed, including in the clinic. Further uses of PFC-based colloidal nanotherapeutics will be briefly mentioned that concern contrast diagnostic imaging, including molecular imaging and immune cell tracking; controlled delivery of therapeutic energy, as for noninvasive surgical ablation and sonothrombolysis; and delivery of drugs and genes, including across the blood-brain barrier. Even when the fluorinated colloids investigated are designed for other purposes than O2 supply, they will inevitably also carry and deliver a certain amount of O2, and may thus be considered for O2 delivery or co-delivery applications. Conversely, O2-carrying PFC nanoemulsions possess by nature a unique aptitude for 19F MR imaging, and hence, cell tracking, while PFC-stabilized microbubbles are ideal resonators for ultrasound contrast imaging and can undergo precise manipulation and on-demand destruction by ultrasound waves, thereby opening multiple theranostic opportunities.
Collapse
Affiliation(s)
- Marie Pierre Krafft
- University of Strasbourg, Institut Charles Sadron (CNRS), 23 rue du Loess, 67034 Strasbourg, France.
| | - Jean G Riess
- Harangoutte Institute, 68160 Ste Croix-aux-Mines, France
| |
Collapse
|
27
|
Xia H, Yang D, He W, Zhu X, Yan Y, Liu Z, Liu T, Yang J, Tan S, Jiang J, Hou X, Gao H, Ni L, Lu J. Ultrasound-mediated microbubbles cavitation enhanced chemotherapy of advanced prostate cancer by increasing the permeability of blood-prostate barrier. Transl Oncol 2021; 14:101177. [PMID: 34271256 PMCID: PMC8287239 DOI: 10.1016/j.tranon.2021.101177] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 07/04/2021] [Accepted: 07/08/2021] [Indexed: 12/25/2022] Open
Abstract
Combination therapy increased cell apoptosis and the inhibition of cell viability. Combination therapy enhanced chemotherapy efficacy by increasing cell permeability. Success in developing an orthotopic model of prostate tumor implantation in mice. Combination therapy inhibited tumor growth and prolonged the survival of mice.
Although chemotherapy is an important treatment for advanced prostate cancer, its efficacy is relatively limited. Ultrasound-induced cavitation plays an important role in drug delivery and gene transfection. However, whether cavitation can improve the efficacy of chemotherapy for prostate cancer remains unclear. In this study, we treated RM-1 mouse prostate carcinoma cells with a combination of ultrasound-mediated microbubble cavitation and paclitaxel. Our results showed that combination therapy led to a more pronounced inhibition of cell viability and increased cell apoptosis. The enhanced efficacy of chemotherapy was attributed to the increased cell permeability induced by cavitation. Importantly, compared with chemotherapy alone (nab-paclitaxel), chemotherapy combined with ultrasound-mediated microbubble cavitation significantly inhibited tumor growth and prolonged the survival of tumor-bearing mice in an orthotopic mouse model of RM-1 prostate carcinoma, indicating the synergistic effects of combined therapy on tumor reduction. Furthermore, we analyzed tumor-infiltrating lymphocytes and found that during chemotherapy, the proportions of CTLA4+ cells and PD-1+/CTLA4+ cells in CD8+ T cells slightly increased after cavitation treatment.
Collapse
Affiliation(s)
- Haizhui Xia
- Department of Urology, Peking University Third Hospital, Beijing 100191, China
| | - Decao Yang
- Institute of Medical Innovation and Research, Peking University Third Hospital, Beijing 100191, China
| | - Wei He
- Department of Urology, Peking University Third Hospital, Beijing 100191, China
| | - Xuehua Zhu
- Department of Urology, Peking University Third Hospital, Beijing 100191, China
| | - Ye Yan
- Department of Urology, Peking University Third Hospital, Beijing 100191, China
| | - Zenan Liu
- Department of Urology, Peking University Third Hospital, Beijing 100191, China
| | - Tong Liu
- Institute of Medical Innovation and Research, Peking University Third Hospital, Beijing 100191, China
| | - Jianling Yang
- Institute of Medical Innovation and Research, Peking University Third Hospital, Beijing 100191, China
| | - Shi Tan
- Department of Ultrasound, Peking University Third Hospital, Beijing 100191, China
| | - Jie Jiang
- Department of Ultrasound, Peking University Third Hospital, Beijing 100191, China
| | - Xiaofei Hou
- Department of Urology, Peking University Third Hospital, Beijing 100191, China
| | - Huile Gao
- Key Laboratory of Drug-Targeting and Drug Delivery System of the Education Ministry, Sichuan Engineering Laboratory for Plant-Sourced Drug and Sichuan Research Center for Drug Precision Industrial Technology, West China School of Pharmacy, Sichuan University, Chengdu 610064, China
| | - Ling Ni
- Institute for Immunology and School of Medicine, Tsinghua University, Medical Research Building, Beijing 100084, China
| | - Jian Lu
- Department of Urology, Peking University Third Hospital, Beijing 100191, China.
| |
Collapse
|
28
|
Montoya Mira J, Wu L, Sabuncu S, Sapre A, Civitci F, Ibsen S, Esener S, Yildirim A. Gas-Stabilizing Sub-100 nm Mesoporous Silica Nanoparticles for Ultrasound Theranostics. ACS OMEGA 2020; 5:24762-24772. [PMID: 33015494 PMCID: PMC7528327 DOI: 10.1021/acsomega.0c03377] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 08/28/2020] [Indexed: 05/22/2023]
Abstract
Recent studies have demonstrated that gas-stabilizing particles can generate cavitating micron-sized bubbles when exposed to ultrasound, offering excellent application potential, including ultrasound imaging, drug delivery, and tumor ablation. However, the majority of the reported gas-stabilizing particles are relatively large (>200 nm), and smaller particles require high acoustic pressures to promote cavitation. Here, this paper reports the preparation of sub-100 nm gas-stabilizing nanoparticles (GSNs) that can initiate cavitation at low acoustic intensities, which can be delivered using a conventional medical ultrasound imaging system. The highly echogenic GSNs (F127-hMSN) were prepared by carefully engineering the surfaces of ∼50 nm mesoporous silica nanoparticles. It was demonstrated that the F127-hMSNs could be continuously imaged with ultrasound in buffer or biological solutions or agarose phantoms for up to 20 min. Also, the F127-hMSN can be stored in phosphate-buffered saline for at least a month with no loss in ultrasound responsiveness. The particles significantly degraded when diluted in simulated body fluids, indicating possible biodegradation of the F127-hMSNs in vivo. Furthermore, at ultrasound imaging conditions, F127-hMSNs did not cause detectable cell death, supporting the potential safety of these particles. Finally, strong cavitation activity generation by the F127-hMSNs under high-intensity focused ultrasound insonation was demonstrated and applied to effectively ablate cancer cells.
Collapse
Affiliation(s)
- Jose Montoya Mira
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
- Biomedical Engineering, School of Medicine, Oregon Health and Science University, Portland, Oregon 97239, United States
| | - Lucy Wu
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Sinan Sabuncu
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Ajay Sapre
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Fehmi Civitci
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| | - Stuart Ibsen
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
- Biomedical Engineering, School of Medicine, Oregon Health and Science University, Portland, Oregon 97239, United States
| | - Sadik Esener
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
- Biomedical Engineering, School of Medicine, Oregon Health and Science University, Portland, Oregon 97239, United States
| | - Adem Yildirim
- CEDAR, Knight Cancer
Institute, School of Medicine, Oregon Health
and Science University, Portland, Oregon 97201, United States
| |
Collapse
|
29
|
Salih M, Ali SM, Jena N, Ananthasubramaniam K. Review of ultrasound contrast agents in current clinical practice with special focus on DEFINITY ® in cardiac imaging. Future Cardiol 2020; 17:197-214. [PMID: 32897099 DOI: 10.2217/fca-2020-0049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Echocardiography is the most widely used noninvasive modality to evaluate the structure and function of the cardiac muscle in daily practice. However, up to 15-20% of echocardiograms are considered suboptimal. To enable accurate assessment of cardiac function and wall motion abnormality, the use of ultrasound microbubble contrast has shown substantial benefits in cases of salvaging nondiagnostic studies and enhancing the diagnostic accuracy in daily practice. DEFINITY® is a perflutren based, lipid shelled microbubble contrast agent, which is US FDA approved for left ventricular opacification. The basis of ultrasound microbubbles, its development, and the clinical role of DEFINITY (characteristics, indications and case examples, side effect profile and existing evidence) is the subject of discussion in this review.
Collapse
Affiliation(s)
- Mohammed Salih
- Department of Medicine, St Joseph Mercy Oakland Hospital, Pontiac, MI 48341, USA
| | - Syed Musadiq Ali
- Department Of Cardiology, Beth Israel Deaconess Hospital, Boston, MA 02215, USA
| | - Nihar Jena
- Department of Medicine, St Joseph Mercy Oakland Hospital, Pontiac, MI 48341, USA
| | | |
Collapse
|
30
|
Yin R, Jiang M, Lv WZ, Jiang F, Li J, Hu B, Cui XW, Dietrich CF. Study Processes and Applications of Ultrasomics in Precision Medicine. Front Oncol 2020; 10:1736. [PMID: 33014858 PMCID: PMC7494734 DOI: 10.3389/fonc.2020.01736] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 08/04/2020] [Indexed: 12/12/2022] Open
Abstract
Ultrasomics is the science of transforming digitally encrypted medical ultrasound images that hold information related to tumor pathophysiology into mineable high-dimensional data. Ultrasomics data have the potential to uncover disease characteristics that are not found with the naked eye. The task of ultrasomics is to quantify the state of diseases using distinctive imaging algorithms and thereby provide valuable information for personalized medicine. Ultrasomics is a powerful tool in oncology but can also be applied to other medical problems for which a disease is imaged. To date there is no comprehensive review focusing on ultrasomics. Here, we describe how ultrasomics works and its capability in diagnosing disease in different organs, including breast, liver, and thyroid. Its pitfalls, challenges and opportunities are also discussed.
Collapse
Affiliation(s)
- Rui Yin
- Department of Ultrasound, Affiliated Renhe Hospital of China Three Gorges University, Yichang, China
| | - Meng Jiang
- Sino-German Tongji-Caritas Research Center of Ultrasound in Medicine, Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wen-Zhi Lv
- Department of Artificial Intelligence, Julei Technology, Wuhan, China
| | - Fan Jiang
- Department of Ultrasound, The Second Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Jun Li
- Department of Ultrasound, The First Affiliated Hospital, School of Medicine, Shihezi University, Shihezi, China
| | - Bing Hu
- Department of Ultrasound, Affiliated Renhe Hospital of China Three Gorges University, Yichang, China
| | - Xin-Wu Cui
- Sino-German Tongji-Caritas Research Center of Ultrasound in Medicine, Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | | |
Collapse
|
31
|
Melich R, Bussat P, Morici L, Vivien A, Gaud E, Bettinger T, Cherkaoui S. Microfluidic preparation of various perfluorocarbon nanodroplets: Characterization and determination of acoustic droplet vaporization (ADV) threshold. Int J Pharm 2020; 587:119651. [DOI: 10.1016/j.ijpharm.2020.119651] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 07/08/2020] [Accepted: 07/10/2020] [Indexed: 12/16/2022]
|
32
|
Liang Y, Yang H, Li Q, Zhao P, Li H, Zhang Y, Cai W, Ma X, Duan Y. Novel biomimetic dual-mode nanodroplets as ultrasound contrast agents with potential ability of precise detection and photothermal ablation of tumors. Cancer Chemother Pharmacol 2020; 86:405-418. [PMID: 32797251 DOI: 10.1007/s00280-020-04124-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 08/04/2020] [Indexed: 01/20/2023]
Abstract
PURPOSE Molecule-targeted ultrasound imaging has attracted extensive attention for precise diagnosis and targeted therapy of tumors. The aim of this research is to prepare novel biomimetic dual-mode nanoscale ultrasound contrast agents (UCAs), which can not only evade the immune clearance of reticuloendothelial system, but also have the potential ability of precise detection and photothermal ablation of tumors. METHODS In this study, for the first time, the novel biomimetic UCAs were prepared by encapsulating liquid perfluorohexanes with red blood cell membranes carrying IR-780 iodide and named IR780-RBCM@NDs. The characteristics of that were verified through the particle size analyzer, scanning electron microscopy, transmission electron microscopy and laser scanning confocal microscopy. The stability of IR780-RBCM@NDs at 37 °C was explored. The abilities of immune escape, dual-mode imaging and photothermal effect for IR780-RBCM@NDs were verified via in vitro experiments. RESULTS The novel prepared nanodroplets have good characteristics such as mean diameter, zeta potential, and relatively stability. Importantly, the integrin-associated protein expressed on the surface of RBCMs was detected on IR780-RBCM@NDs. Then, compared with control groups, IR780-RBCM@NDs performed excellent immune escape function away from macrophages in vitro. Furthermore, the IR-780 iodide was observed on the new nanodroplets and that was able to perform the dual-mode imaging with near-infrared fluorescence imaging and contrast-enhanced ultrasound imaging after the phase change. Finally, the effective photothermal ablation ability of IR780-RBCM@NDs was verified in tumor cells. CONCLUSION The newly prepared biomimetic IR780-RBCM@NDs provided novel ideas for evading immune clearance, performing precise diagnosis and photothermal ablation of tumor cells.
Collapse
Affiliation(s)
- Yuan Liang
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Air Force Medical University, Xi'an, China
| | - Hengli Yang
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Xi'an Medical College, Xi'an, China.
| | - Qiaoying Li
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Air Force Medical University, Xi'an, China
| | - Ping Zhao
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Air Force Medical University, Xi'an, China
| | - Han Li
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Air Force Medical University, Xi'an, China
| | - Yuxin Zhang
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Air Force Medical University, Xi'an, China
| | - Wenbin Cai
- Special Diagnosis Department, General Hospital of Tibet Military Command, Lhasa, China
| | - Xiaoju Ma
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Air Force Medical University, Xi'an, China
| | - Yunyou Duan
- Department of Ultrasound Diagnosis, The Second Affiliated Hospital, Air Force Medical University, Xi'an, China.
| |
Collapse
|
33
|
Beyer T, Bidaut L, Dickson J, Kachelriess M, Kiessling F, Leitgeb R, Ma J, Shiyam Sundar LK, Theek B, Mawlawi O. What scans we will read: imaging instrumentation trends in clinical oncology. Cancer Imaging 2020; 20:38. [PMID: 32517801 PMCID: PMC7285725 DOI: 10.1186/s40644-020-00312-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 04/17/2020] [Indexed: 12/16/2022] Open
Abstract
Oncological diseases account for a significant portion of the burden on public healthcare systems with associated costs driven primarily by complex and long-lasting therapies. Through the visualization of patient-specific morphology and functional-molecular pathways, cancerous tissue can be detected and characterized non-invasively, so as to provide referring oncologists with essential information to support therapy management decisions. Following the onset of stand-alone anatomical and functional imaging, we witness a push towards integrating molecular image information through various methods, including anato-metabolic imaging (e.g., PET/CT), advanced MRI, optical or ultrasound imaging. This perspective paper highlights a number of key technological and methodological advances in imaging instrumentation related to anatomical, functional, molecular medicine and hybrid imaging, that is understood as the hardware-based combination of complementary anatomical and molecular imaging. These include novel detector technologies for ionizing radiation used in CT and nuclear medicine imaging, and novel system developments in MRI and optical as well as opto-acoustic imaging. We will also highlight new data processing methods for improved non-invasive tissue characterization. Following a general introduction to the role of imaging in oncology patient management we introduce imaging methods with well-defined clinical applications and potential for clinical translation. For each modality, we report first on the status quo and, then point to perceived technological and methodological advances in a subsequent status go section. Considering the breadth and dynamics of these developments, this perspective ends with a critical reflection on where the authors, with the majority of them being imaging experts with a background in physics and engineering, believe imaging methods will be in a few years from now. Overall, methodological and technological medical imaging advances are geared towards increased image contrast, the derivation of reproducible quantitative parameters, an increase in volume sensitivity and a reduction in overall examination time. To ensure full translation to the clinic, this progress in technologies and instrumentation is complemented by advances in relevant acquisition and image-processing protocols and improved data analysis. To this end, we should accept diagnostic images as “data”, and – through the wider adoption of advanced analysis, including machine learning approaches and a “big data” concept – move to the next stage of non-invasive tumour phenotyping. The scans we will be reading in 10 years from now will likely be composed of highly diverse multi-dimensional data from multiple sources, which mandate the use of advanced and interactive visualization and analysis platforms powered by Artificial Intelligence (AI) for real-time data handling by cross-specialty clinical experts with a domain knowledge that will need to go beyond that of plain imaging.
Collapse
Affiliation(s)
- Thomas Beyer
- QIMP Team, Centre for Medical Physics and Biomedical Engineering, Medical University Vienna, Währinger Gürtel 18-20/4L, 1090, Vienna, Austria.
| | - Luc Bidaut
- College of Science, University of Lincoln, Lincoln, UK
| | - John Dickson
- Institute of Nuclear Medicine, University College London Hospital, London, UK
| | - Marc Kachelriess
- Division of X-ray imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, DE, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 20, 52074, Aachen, DE, Germany.,Fraunhofer Institute for Digital Medicine MEVIS, Am Fallturm 1, 28359, Bremen, DE, Germany
| | - Rainer Leitgeb
- Centre for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, AT, Austria
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Lalith Kumar Shiyam Sundar
- QIMP Team, Centre for Medical Physics and Biomedical Engineering, Medical University Vienna, Währinger Gürtel 18-20/4L, 1090, Vienna, Austria
| | - Benjamin Theek
- Institute for Experimental Molecular Imaging, University Clinic and Helmholtz Institute for Biomedical Engineering, RWTH Aachen University, Pauwelsstrasse 20, 52074, Aachen, DE, Germany.,Fraunhofer Institute for Digital Medicine MEVIS, Am Fallturm 1, 28359, Bremen, DE, Germany
| | - Osama Mawlawi
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
34
|
Facchin C, Perez-Liva M, Garofalakis A, Viel T, Certain A, Balvay D, Yoganathan T, Woszczyk J, De Sousa K, Sourdon J, Provost J, Tanter M, Lussey-Lepoutre C, Favier J, Tavitian B. Concurrent imaging of vascularization and metabolism in a mouse model of paraganglioma under anti-angiogenic treatment. Theranostics 2020; 10:3518-3532. [PMID: 32206105 PMCID: PMC7069082 DOI: 10.7150/thno.40687] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Accepted: 01/23/2020] [Indexed: 11/21/2022] Open
Abstract
Rationale: Deregulation of metabolism and induction of vascularization are major hallmarks of cancer. Using a new multimodal preclinical imaging instrument, we explored a sequence of events leading to sunitinib-induced resistance in a murine model of paraganglioma (PGL) invalidated for the expression of succinate dehydrogenase subunit B (Sdhb-/-). Methods: Two groups of Sdhb-/- tumors bearing mice were treated with sunitinib (6 weeks) or vehicle (3 weeks). Concurrent Positron Emission Tomography (PET) with 2′ -deoxy-2′-[18F]fluoro-D-glucose (FDG), Computed Tomography (CT) and Ultrafast Ultrasound Imaging (UUI) imaging sessions were performed once a week and ex vivo samples were analyzed by western blots and histology. Results: PET-CT-UUI enabled to detect a rapid growth of Sdhb-/- tumors with increased glycolysis and vascular development. Sunitinib treatment prevented tumor growth, vessel development and reduced FDG uptake at week 1 and 2 (W1-2). Thereafter, imaging revealed tumor escape from sunitinib treatment: FDG uptake in tumors increased at W3, followed by tumor growth and vessel development at W4-5. Perfused vessels were preferentially distributed in the hypermetabolic regions of the tumors and the perfused volume increased during escape from sunitinib treatment. Finally, initial changes in total lesion glycolysis and maximum vessel length at W1 were predictive of resistance to sunitinib. Conclusion: These results demonstrate an adaptive resistance of Sdhb-/- tumors to six weeks of sunitinib treatment. Early metabolic changes and delayed vessel architecture changes were detectable and predictable in vivo early during anti-angiogenic treatment. Simultaneous metabolic, anatomical and functional imaging can monitor precisely the effects of anti-angiogenic treatment of tumors.
Collapse
|
35
|
May JN, Golombek SK, Baues M, Dasgupta A, Drude N, Rix A, Rommel D, von Stillfried S, Appold L, Pola R, Pechar M, van Bloois L, Storm G, Kuehne AJC, Gremse F, Theek B, Kiessling F, Lammers T. Multimodal and multiscale optical imaging of nanomedicine delivery across the blood-brain barrier upon sonopermeation. Am J Cancer Res 2020; 10:1948-1959. [PMID: 32042346 PMCID: PMC6993230 DOI: 10.7150/thno.41161] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 11/20/2019] [Indexed: 01/15/2023] Open
Abstract
Rationale: The blood-brain barrier (BBB) is a major obstacle for drug delivery to the brain. Sonopermeation, which relies on the combination of ultrasound and microbubbles, has emerged as a powerful tool to permeate the BBB, enabling the extravasation of drugs and drug delivery systems (DDS) to and into the central nervous system (CNS). When aiming to improve the treatment of high medical need brain disorders, it is important to systematically study nanomedicine translocation across the sonopermeated BBB. To this end, we here employed multimodal and multiscale optical imaging to investigate the impact of DDS size on brain accumulation, extravasation and penetration upon sonopermeation. Methods: Two prototypic DDS, i.e. 10 nm-sized pHPMA polymers and 100 nm-sized PEGylated liposomes, were labeled with fluorophores and intravenously injected in healthy CD-1 nude mice. Upon sonopermeation, computed tomography-fluorescence molecular tomography, fluorescence reflectance imaging, fluorescence microscopy, confocal microscopy and stimulated emission depletion nanoscopy were used to study the effect of DDS size on their translocation across the BBB. Results: Sonopermeation treatment enabled safe and efficient opening of the BBB, which was confirmed by staining extravasated endogenous IgG. No micro-hemorrhages, edema and necrosis were detected in H&E stainings. Multimodal and multiscale optical imaging showed that sonopermeation promoted the accumulation of nanocarriers in mouse brains, and that 10 nm-sized polymeric DDS accumulated more strongly and penetrated deeper into the brain than 100 nm-sized liposomes. Conclusions: BBB opening via sonopermeation enables safe and efficient delivery of nanomedicine formulations to and into the brain. When looking at accumulation and penetration (and when neglecting issues such as drug loading capacity and therapeutic efficacy) smaller-sized DDS are found to be more suitable for drug delivery across the BBB than larger-sized DDS. These findings are valuable for better understanding and further developing nanomedicine-based strategies for the treatment of CNS disorders.
Collapse
|
36
|
Abstract
Contrast-enhanced ultrasound (CEUS) imaging is a valuable tool for preclinical and clinical diagnostics. The most frequently used ultrasound contrast agents are microbubbles. Besides them, novel nano-sized materials are under investigation, which are briefly discussed in this chapter. For molecular CEUS, the ultrasound contrast agents are modified to actively target disease-associated molecular markers with a site-specific ligand. The most common markers for tumor imaging are related to neoangiogenesis, like the vascular endothelial growth factor receptor-2 (VEGFR2) and αvβ3 integrin. In this chapter, applications of molecular ultrasound to longitudinally monitor receptor expression during tumor growth, to detect neovascularization, and to evaluate therapy responses are described. Furthermore, we report on first clinical trials of molecular CEUS with VEGFR2-targeted phospholipid microbubbles showing promising results regarding patient safety and its ability to detect tumors of prostate, breast, and ovary. The chapter closes with an outlook on ultrasound theranostics, where (targeted) ultrasound contrast agents are used to increase the permeability of tumor tissues and to support drug delivery.
Collapse
Affiliation(s)
- Jasmin Baier
- Institute for Experimental Molecular Imaging Organization University Clinics, RWTH Aachen University, Forckenbeckstrasse 55, 52074 Aachen, Germany
| | - Anne Rix
- Institute for Experimental Molecular Imaging Organization University Clinics, RWTH Aachen University, Forckenbeckstrasse 55, 52074 Aachen, Germany
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging Organization University Clinics, RWTH Aachen University, Forckenbeckstrasse 55, 52074 Aachen, Germany.
| |
Collapse
|
37
|
Tharkar P, Varanasi R, Wong WSF, Jin CT, Chrzanowski W. Nano-Enhanced Drug Delivery and Therapeutic Ultrasound for Cancer Treatment and Beyond. Front Bioeng Biotechnol 2019; 7:324. [PMID: 31824930 PMCID: PMC6883936 DOI: 10.3389/fbioe.2019.00324] [Citation(s) in RCA: 87] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 10/28/2019] [Indexed: 12/24/2022] Open
Abstract
While ultrasound is most widely known for its use in diagnostic imaging, the energy carried by ultrasound waves can be utilized to influence cell function and drug delivery. Consequently, our ability to use ultrasound energy at a given intensity unlocks the opportunity to use the ultrasound for therapeutic applications. Indeed, in the last decade ultrasound-based therapies have emerged with promising treatment modalities for several medical conditions. More recently, ultrasound in combination with nanomedicines, i.e., nanoparticles, has been shown to have substantial potential to enhance the efficacy of many treatments including cancer, Alzheimer disease or osteoarthritis. The concept of ultrasound combined with drug delivery is still in its infancy and more research is needed to unfold the mechanisms and interactions of ultrasound with different nanoparticles types and with various cell types. Here we present the state-of-art in ultrasound and ultrasound-assisted drug delivery with a particular focus on cancer treatments. Notably, this review discusses the application of high intensity focus ultrasound for non-invasive tumor ablation and immunomodulatory effects of ultrasound, as well as the efficacy of nanoparticle-enhanced ultrasound therapies for different medical conditions. Furthermore, this review presents safety considerations related to ultrasound technology and gives recommendations in the context of system design and operation.
Collapse
Affiliation(s)
- Priyanka Tharkar
- Faculty of Medicine and Health, Sydney School of Pharmacy, Sydney Nano Institute, The University of Sydney, Camperdown, NSW, Australia
| | - Ramya Varanasi
- Faculty of Medicine and Health, Sydney School of Pharmacy, Sydney Nano Institute, The University of Sydney, Camperdown, NSW, Australia
| | - Wu Shun Felix Wong
- School of Women's and Children's Health, University of New South Wales, Sydney, NSW, Australia
| | - Craig T Jin
- Faculty of Engineering, School of Electrical and Information Engineering, The University of Sydney, Sydney, NSW, Australia
| | - Wojciech Chrzanowski
- Faculty of Medicine and Health, Sydney School of Pharmacy, Sydney Nano Institute, The University of Sydney, Camperdown, NSW, Australia
| |
Collapse
|
38
|
Drug-Loaded Microbubbles Combined with Ultrasound for Thrombolysis and Malignant Tumor Therapy. BIOMED RESEARCH INTERNATIONAL 2019; 2019:6792465. [PMID: 31662987 PMCID: PMC6791276 DOI: 10.1155/2019/6792465] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 07/22/2019] [Accepted: 09/14/2019] [Indexed: 12/14/2022]
Abstract
Cardiac-cerebral thrombosis and malignant tumor endanger the safety of human life seriously. Traditional chemotherapy drugs have side effects which restrict their applications. Drug-loaded microbubbles can be destroyed by ultrasound irradiation at the focus position and be used for thrombolysis and tumor therapy. Compared with traditional drug treatment, the drug-loaded microbubbles can be excited by ultrasound and release drugs to lesion sites, increasing the local drug concentration and the exposure dose to nonfocal regions, thus reducing the cytotoxicity and side effects of drugs. This article reviews the applications of drug-loaded microbubbles combined with ultrasound for thrombolysis and tumor therapy. We focus on highlighting the advantages of using this new technique for disease treatment and concluding with recommendations for future efforts on the applications of this technology.
Collapse
|
39
|
D'Souza JC, Sultan LR, Hunt SJ, Schultz SM, Brice AK, Wood AKW, Sehgal CM. B-mode ultrasound for the assessment of hepatic fibrosis: a quantitative multiparametric analysis for a radiomics approach. Sci Rep 2019; 9:8708. [PMID: 31213661 PMCID: PMC6581954 DOI: 10.1038/s41598-019-45043-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Accepted: 05/29/2019] [Indexed: 01/03/2023] Open
Abstract
Hepatic fibrosis and cirrhosis are a growing global health problem with increasing mortality rates. Early diagnosis and staging of hepatic fibrosis represent a major challenge. Currently liver biopsy is the gold standard for fibrosis assessment; however, biopsy requires an invasive procedure and is prone to sampling error and reader variability. In the current study we investigate using quantitative analysis of computer-extracted features of B-mode ultrasound as a non-invasive tool to characterize hepatic fibrosis. Twenty-two rats were administered diethylnitrosamine (DEN) orally for 12 weeks to induce hepatic fibrosis. Four control rats did not receive DEN. B-mode ultrasound scans sampling throughout the liver were acquired at baseline, 10, and 13 weeks. Computer extracted quantitative parameters representing brightness (echointensity, hepatorenal index) and variance (heterogeneity, anisotropy) of the liver were studied. DEN rats showed an increase in echointensity from 37.1 ± SD 7.8 to 53.5 ± 5.7 (10 w) to 57.5 ± 6.1 (13 w), while the control group remained unchanged at an average of 34.5 ± 4.5. The three other features studied increased similarly over time in the DEN group. Histologic analysis showed METAVIR fibrosis grades of F2-F4 in DEN rats and F0-F1 in controls. Increasing imaging parameters correlated with increasing METAVIR grades, and anisotropy showed the strongest correlation (ρ = 0.58). Sonographic parameters combined using multiparametric logistic regression were able to differentiate between clinically significant and insignificant fibrosis. Quantitative B-mode ultrasound imaging can be implemented in clinical settings as an accurate non-invasive tool for fibrosis assessment.
Collapse
Affiliation(s)
- Julia C D'Souza
- Ultrasound Research Lab, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.,Penn Image-Guided Interventions Lab, University of Pennsylvania, Philadelphia, PA, USA
| | - Laith R Sultan
- Ultrasound Research Lab, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
| | - Stephen J Hunt
- Ultrasound Research Lab, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.,Penn Image-Guided Interventions Lab, University of Pennsylvania, Philadelphia, PA, USA
| | - Susan M Schultz
- Ultrasound Research Lab, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Angela K Brice
- University Laboratory Animal Resources, University of Pennsylvania, Philadelphia, PA, USA.,Department of Pathobiology, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Andrew K W Wood
- Ultrasound Research Lab, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.,Department of Pathobiology, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Chandra M Sehgal
- Ultrasound Research Lab, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
40
|
Snipstad S, Sulheim E, de Lange Davies C, Moonen C, Storm G, Kiessling F, Schmid R, Lammers T. Sonopermeation to improve drug delivery to tumors: from fundamental understanding to clinical translation. Expert Opin Drug Deliv 2018; 15:1249-1261. [PMID: 30415585 DOI: 10.1080/17425247.2018.1547279] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Ultrasound in combination with microbubbles can make cells and tissues more accessible for drugs, thereby achieving improved therapeutic outcomes. In this review, we introduce the term 'sonopermeation', covering mechanisms such as pore formation (traditional sonoporation), as well as the opening of intercellular junctions, stimulated endocytosis/transcytosis, improved blood vessel perfusion and changes in the (tumor) microenvironment. Sonopermeation has gained a lot of interest in recent years, especially for delivering drugs through the otherwise impermeable blood-brain barrier, but also to tumors. AREAS COVERED In this review, we summarize various in vitro assays and in vivo setups that have been employed to unravel the fundamental mechanisms involved in ultrasound-enhanced drug delivery, as well as clinical trials that are ongoing in patients with brain, pancreatic, liver and breast cancer. We summarize the basic principles of sonopermeation, describe recent findings obtained in (pre-) clinical trials, and discuss future directions. EXPERT OPINION We suggest that an improved mechanistic understanding, and microbubbles and ultrasound equipment specialized for drug delivery (and not for imaging) are key aspects to create more effective treatment regimens by sonopermeation. Real-time feedback and tools to predict therapeutic outcome and which tumors/patients will benefit from sonopermeation-based interventions will be important to promote clinical translation.
Collapse
Affiliation(s)
- Sofie Snipstad
- a Department of Physics , Norwegian University of Science and Technology (NTNU) , Trondheim , Norway.,b Department of Biotechnology and Nanomedicine , SINTEF AS , Trondheim , Norway.,c Cancer Clinic , St. Olavs Hospital , Trondheim , Norway
| | - Einar Sulheim
- a Department of Physics , Norwegian University of Science and Technology (NTNU) , Trondheim , Norway.,b Department of Biotechnology and Nanomedicine , SINTEF AS , Trondheim , Norway.,c Cancer Clinic , St. Olavs Hospital , Trondheim , Norway
| | - Catharina de Lange Davies
- a Department of Physics , Norwegian University of Science and Technology (NTNU) , Trondheim , Norway
| | - Chrit Moonen
- d Imaging Division , University Medical Center , Utrecht , The Netherlands
| | - Gert Storm
- e Department of Pharmaceutics , Utrecht University , Utrecht , The Netherlands.,f Department of Targeted Therapeutics , University of Twente , Enschede , The Netherlands
| | - Fabian Kiessling
- g Institute for Experimental Molecular Imaging , RWTH Aachen University , Aachen , Germany
| | - Ruth Schmid
- b Department of Biotechnology and Nanomedicine , SINTEF AS , Trondheim , Norway
| | - Twan Lammers
- e Department of Pharmaceutics , Utrecht University , Utrecht , The Netherlands.,f Department of Targeted Therapeutics , University of Twente , Enschede , The Netherlands.,g Institute for Experimental Molecular Imaging , RWTH Aachen University , Aachen , Germany
| |
Collapse
|
41
|
A High-Efficiency Super-Resolution Reconstruction Method for Ultrasound Microvascular Imaging. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8071143] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The emergence of super-resolution imaging makes it possible to display the microvasculatures clearly using ultrasound imaging, which is of great importance in the early diagnosis of cancer. At present, the super-resolution performance can only be achieved when the sampling signal is long enough (usually more than 10,000 frames). Thus, the imaging time resolution is not suitable for clinical use. In this paper, we proposed a novel super-resolution reconstruction method, which is proved to have a satisfactory resolution using shorter sampling signal sequences. In the microbubble localization step, the integrated form of the 2D Gaussian function is innovatively adopted for image deconvolution in our method, which enhances the accuracy of microbubble positioning. In the trajectory tracking step, for the first time the averaged shifted histogram technique is presented for the visualization, which greatly improves the precision of reconstruction. In vivo experiments on rabbits were conducted to verify the effectiveness of the proposed method. Compared to the conventional reconstruction method, our method significantly reduces the Full-Width-at-Half-Maximum (FWHM) by 50% using only 400-frame signals. Besides, there is no significant increase in the running time using the proposed method. Considering its imaging performance and used frame number, the conclusion can be drawn that the proposed method advances the application of super-resolution imaging to the clinical use with a much higher time resolution.
Collapse
|