1
|
Draeger E, Roberts K, Decker RD, Bahar N, Wilson LD, Contessa J, Husain Z, Williams BB, Flood AB, Swartz HM, Carlson DJ. In Vivo Verification of Electron Paramagnetic Resonance Biodosimetry Using Patients Undergoing Radiation Therapy Treatment. Int J Radiat Oncol Biol Phys 2024; 119:292-301. [PMID: 38072322 DOI: 10.1016/j.ijrobp.2023.11.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 09/28/2023] [Accepted: 11/19/2023] [Indexed: 01/06/2024]
Abstract
PURPOSE Electron paramagnetic resonance (EPR) biodosimetry, used to triage large numbers of individuals incidentally exposed to unknown doses of ionizing radiation, is based on detecting a stable physical response in the body that is subject to quantifiable variation after exposure. In vivo measurement is essential to fully characterize the radiation response relevant to a living tooth measured in situ. The purpose of this study was to verify EPR spectroscopy in vivo by estimating the radiation dose received in participants' teeth. METHODS AND MATERIALS A continuous wave L-band spectrometer was used for EPR measurements. Participants included healthy volunteers and patients undergoing head and neck and total body irradiation treatments. Healthy volunteers completed 1 measurement each, and patients underwent measurement before starting treatment and between subsequent fractions. Optically stimulated luminescent dosimeters and diodes were used to determine the dose delivered to the teeth to validate EPR measurements. RESULTS Seventy measurements were acquired from 4 total body irradiation and 6 head and neck patients over 15 months. Patient data showed a linear increase of EPR signal with delivered dose across the dose range tested. A linear least-squares weighted fit of the data gave a statistically significant correlation between EPR signal and absorbed dose (P < .0001). The standard error of inverse prediction (SEIP), used to assess the usefulness of fits, was 1.92 Gy for the dose range most relevant for immediate triage (≤7 Gy). Correcting for natural background radiation based on patient age reduced the SEIP to 1.51 Gy. CONCLUSIONS This study demonstrated the feasibility of using spectroscopic measurements from radiation therapy patients to validate in vivo EPR biodosimetry. The data illustrated a statistically significant correlation between the magnitude of EPR signals and absorbed dose. The SEIP of 1.51 Gy, obtained under clinical conditions, indicates the potential value of this technique in response to large radiation events.
Collapse
Affiliation(s)
- Emily Draeger
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut.
| | - Kenneth Roberts
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Roy D Decker
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Nina Bahar
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Lynn D Wilson
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Joseph Contessa
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Zain Husain
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Benjamin B Williams
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - Ann Barry Flood
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - Harold M Swartz
- Department of Radiology & EPR Center, Geisel Medical School at Dartmouth, Hanover, New Hampshire
| | - David J Carlson
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut.
| |
Collapse
|
2
|
Park JI, Koo CU, Oh J, Kim IJ, Choi K, Ye SJ. Enhancing Precision in L-band Electron Paramagnetic Resonance Tooth Dosimetry: Incorporating Digital Image Processing and Radiation Therapy Plans for Geometric Correction. HEALTH PHYSICS 2024; 126:79-95. [PMID: 37948057 DOI: 10.1097/hp.0000000000001773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2023]
Abstract
ABSTRACT Following unforeseen exposure to radiation, quick dose determination is essential to prioritize potential patients that require immediate medical care. L-band electron paramagnetic resonance tooth dosimetry can be efficiently used for rapid triage as this poses no harm to the human incisor, although geometric variations among human teeth may hinder accurate dose estimation. Consequently, we propose a practical geometric correction method using a mobile phone camera. Donated human incisors were irradiated with calibrated 6-MV photon beam irradiation, and dose-response curves were developed by irradiation with a predetermined dose using custom-made poly(methyl methacrylate) slab phantoms. Three radiation treatment plans for incisors were selected and altered to suit the head phantom. The mean doses on tooth structures were calculated using a commercial treatment planning system, and the electron paramagnetic resonance signals of the incisors were measured. The enamel area was computed from camera-acquired tooth images. The relative standard uncertainty was rigorously estimated both with and without geometric correction. The effects on the electron paramagnetic resonance signal caused by axial and rotational movements of tooth samples were evaluated through finite element analysis. The mean absolute deviations of mean doses both with and without geometric correction showed marginal improvement. The average relative differences without and with geometric correction significantly decreased from 21.0% to 16.8% (p = 0.01). The geometric correction method shows potential in improving dose precision measurement with minimal delay. Furthermore, our findings demonstrated the viability of using treatment planning system doses in dose estimation for L-band electron paramagnetic resonance tooth dosimetry.
Collapse
Affiliation(s)
- Jong In Park
- Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
| | - Chang Uk Koo
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | - Jeonghun Oh
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | - In Jung Kim
- Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea
| | - Kwon Choi
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | | |
Collapse
|
3
|
Choi K, Koo CU, Oh J, Kim J, Park JI, Kim SH, Lee JH, Kang DG, Ye SJ. Enhanced Dosimetric Accuracy Using Quality Factor Compensation Method for In Vivo Electron Paramagnetic Resonance Tooth Dosimetry. HEALTH PHYSICS 2023; 125:352-361. [PMID: 37565831 DOI: 10.1097/hp.0000000000001727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/12/2023]
Abstract
ABSTRACT We aim to develop a dose assessment method compensating for quality factors (Q factor) observed during in vivo EPR tooth dosimetry. A pseudo-in-vivo phantom made of tissue-equivalent material was equipped with one each of four extracted human central incisors. A range of Q factors was measured at tooth-depths of -2, 0, and 2 mm in the pseudo-in-vivo phantom. In addition, in vivo Q factors were measured from nine human volunteers. For the dose-response data, the above four sample teeth were irradiated at 0, 1, 2, 5, and 10 Gy, and the radiation-induced signals were measured at the same tooth-depths using an in vivo EPR tooth dosimetry system. To validate the method, the signals of two post-radiotherapy patients and three unirradiated volunteers were measured using the same system. The interquartile range of the Q factors measured in the pseudo-in-vivo phantom covered that observed from the human volunteers, which implied that the phantom represented the Q factor distribution of in vivo conditions. The dosimetric sensitivities and background signals were decreased as increasing the tooth-depth in the phantom due to the decrease in Q factors. By compensating for Q factors, the diverged dose-response data due to various Q factors were converged to improve the dosimetric accuracy in terms of the standard error of inverse prediction (SEIP). The Q factors of patient 1 and patient 2 were 98 and 64, respectively, while the three volunteers were 100, 92, and 99. The assessed doses of patient 1 and patient 2 were 2.73 and 12.53 Gy, respectively, while expecting 4.43 and 13.29 Gy, respectively. The assessed doses of the unirradiated volunteers were 0.53, 0.50, and - 0.22 Gy. We demonstrated that the suggested Q factor compensation could mitigate the uncertainty induced by the variation of Q factors.
Collapse
Affiliation(s)
- Kwon Choi
- Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Korea
| | - Chang Uk Koo
- Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Korea
| | - Jeonghun Oh
- Program in Biomedical Radiation Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Korea
| | - Jiwon Kim
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Korea
| | - Jong In Park
- Ionizing Radiation Metrology Group, Korea Research Institute of Standards and Science, Daejeon 34113, Korea
| | - Sung Hwan Kim
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon 16247, Korea
| | - Jong Hoon Lee
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon 16247, Korea
| | - Dae Gyu Kang
- Department of Radiation Oncology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Suwon 16247, Korea
| | | |
Collapse
|
4
|
Karim ET, Szalai V, Cumberland L, Myers AF, Takagi S, Frukhtbeyn SA, Pazos I, Chow LC. Electron Paramagnetic Resonance Characterization of Sodium- and Carbonate-Containing Hydroxyapatite Cement. Inorg Chem 2022; 61:13022-13033. [PMID: 35930806 PMCID: PMC9400659 DOI: 10.1021/acs.inorgchem.2c01177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Ionizing radiation-induced paramagnetic defects in calcified tissues like tooth enamel are indicators of irradiation dose. Hydroxyapatite (HA), the principal constituent in these materials, incorporates a variety of anions (CO32-, F-, Cl-, and SiO44-) and cations (Mn2+, Li+, Cu2+, Fe3+, Mg2+, and Na+) that directly or indirectly contribute to the formation of stable paramagnetic centers upon irradiation. Here, we used an underexploited synthesis method based on the ambient temperature setting reaction of a self-hardening calcium phosphate cement (CPC) to create carbonate-containing hydroxyapatite (CHA) and investigate its paramagnetic properties following γ-irradiation. Powder X-ray diffraction and IR spectroscopic characterization of the hardened CHA samples indicate the formation of pure B-type CHA cement. CHA samples exposed to γ-radiation doses ranging from 1 Gy to 150 kGy exhibited an electron paramagnetic resonance (EPR) signal from an orthorhombic CO2•- free radical. At γ-radiation doses from 30 to 150 kGy, a second signal emerged that is assigned to the CO3•- free radical. We observed that the formation of this second species is dose-dependent, which provided a means to extend the useful dynamic range of irradiated CHA to doses >30 kGy. These results indicate that CHA synthesized via a CPC cement is a promising substrate for EPR-based dosimetry. Further studies on the CHA cement are underway to determine the suitability of these materials for a range of biological and industrial dosimetry applications.
Collapse
Affiliation(s)
- Eaman T Karim
- American Dental Association Science and Research Institute, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Veronika Szalai
- Microsystems and Nanotechnology Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Lonnie Cumberland
- Radiation Physics Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Alline F Myers
- Center for Nanoscale Science and Technology, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Shozo Takagi
- American Dental Association Science and Research Institute, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Stanislav A Frukhtbeyn
- American Dental Association Science and Research Institute, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Ileana Pazos
- Radiation Physics Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| | - Laurence C Chow
- American Dental Association Science and Research Institute, 100 Bureau Drive, Gaithersburg, Maryland 20899, United States
| |
Collapse
|
5
|
X-band TE101 rectangular aperture cavity for in vivo EPR tooth dosimetry after radiation emergency. Appl Radiat Isot 2021; 178:109958. [PMID: 34598040 DOI: 10.1016/j.apradiso.2021.109958] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 08/25/2021] [Accepted: 09/16/2021] [Indexed: 11/22/2022]
Abstract
The TE101 mode rectangle EPR cavity was newly developed to achieve X-band in vivo EPR tooth dosimetry for the rescue of nuclear emergency. An aperture for sample detection was opened on the cavity's surface. Its characteristics were evaluated by measuring DPPH and intact human incisor samples. Remarkable radiation induced signal from EPR spectrum of 1Gy-8Gy irradiated teeth was observed. In vivo measurements of rat was performed to verify its application for in vivo tooth dosimetry.
Collapse
|
6
|
Park JI, Choi K, Koo CU, Oh J, Hirata H, Swartz HM, Ye SJ. Dependence of Radiation-induced Signals on Geometry of Tooth Enamel Using a 1.15 GHz Electron Paramagnetic Resonance Spectrometer: Improvement of Dosimetric Accuracy. HEALTH PHYSICS 2021; 120:152-162. [PMID: 32701613 DOI: 10.1097/hp.0000000000001292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
ABSTRACT We aim to improve the accuracy of electron paramagnetic resonance (EPR)-based in vivo tooth dosimetry using the relationship between tooth geometry and radiation-induced signals (RIS). A homebuilt EPR spectrometer at L-band frequency of 1.15 GHz originally designed for non-invasive and in vivo measurements of intact teeth was used to measure the RIS of extracted human teeth. Twenty human central incisors were scanned by microCT and irradiated by 220 kVp x-rays. The RISs of the samples were measured by the EPR spectrometer as well as simulated by using the finite element analysis of the electromagnetic field. A linear relationship between simulated RISs and tooth geometric dimensions, such as enamel area, enamel volume, and labial enamel volume, was confirmed. The dose sensitivity was quantified as a slope of the calibration curve (i.e., RIS vs. dose) for each tooth sample. The linear regression of these dose sensitivities was established for each of three tooth geometric dimensions. Based on these findings, a method for the geometry correction was developed by use of expected dose sensitivity of a certain tooth for one of the tooth geometric dimensions. Using upper incisors, the mean absolute deviation (MAD) without correction was 1.48 Gy from an estimated dose of 10 Gy; however, the MAD corrected by enamel area, volume, and labial volume was reduced to 1.04 Gy, 0.77 Gy, and 0.83 Gy, respectively. In general, the method corrected by enamel volume showed the best accuracy in this study. This homebuilt EPR spectrometer for the purpose of non-invasive and in vivo tooth dosimetry was successfully tested for achieving measurements in situ. We demonstrated that the developed correction method could reduce dosimetric uncertainties resulting from the variations in tooth geometric dimensions.
Collapse
Affiliation(s)
| | | | | | - Jeonghun Oh
- Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea
| | - Hiroshi Hirata
- Division of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Sapporo, 060-0814, Japan
| | - Harold M Swartz
- Geisel School of Medicine, HB 7785 Dartmouth College, Hanover, NH 03755
| | | |
Collapse
|
7
|
Zou J, Guo J, Ma L, Dong G, Cong J, Liu Y, Tian Y, Wu K. A normalization method of the volume and geometry of tooth for X-band in vivo EPR dosimetry. Appl Radiat Isot 2019; 149:123-129. [PMID: 31054478 DOI: 10.1016/j.apradiso.2019.04.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 04/16/2019] [Accepted: 04/17/2019] [Indexed: 11/29/2022]
Abstract
The accuracy of in vivo EPR tooth dosimetry may be influenced by the volume and geometry variations in teeth, especially when there is considerable non-uniform sensitivity distribution in the active detection area of the cavity. To solve this problem, the present research proposed a normalization method specifically for X-band EPR in vivo tooth dosimetry. The volume and geometry of the measured tooth were reconstructed by digital image processing with images of the tooth impression slices, which were obtained by a custom-made impression module. The sensitivity distribution in the active detection area was established based on experiments with a point sample. Consequently, a composite normalization process that could calibrate the evaluated dose effectively was carried out by taking into account the influences not only from tooth volume and geometry but also from the non-uniform distribution of sensitivity. The effect and practicability of the method were evaluated by incisor samples. Results showed that the standard deviation could be reduced a maximum of 54.8% approximately after the composite normalization, an improvement compared to results from solely tooth volume. The correlation coefficient of the dose-response curve could be improved from 0.731 to 0.986. The preliminary method provides an approach potentially useful on site after radiation accidents when dealing with the influence of variations in the tooth volume and geometry for X-band EPR in vivo dose estimations.
Collapse
Affiliation(s)
- Jierui Zou
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
| | - Junwang Guo
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
| | - Lei Ma
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
| | - Guofu Dong
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
| | - Jianbo Cong
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
| | - Ye Liu
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
| | - Ye Tian
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
| | - Ke Wu
- Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China.
| |
Collapse
|
8
|
Kobayashi K, Dong R, Nicolalde RJ, Calderon P, Du G, Williams BB, Lee MCI, Swartz HM, Flood AB. Development of a novel mouth model as an alternative tool to test the effectiveness of an in vivo EPR dosimetry system. Phys Med Biol 2018; 63:165002. [PMID: 30033935 DOI: 10.1088/1361-6560/aad518] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In a large-scale radiation event, thousands may be exposed to unknown amounts of radiation, some of which may be life-threatening without immediate attention. In such situations, a method to quickly and reliably estimate dose would help medical responders triage victims to receive life-saving care. We developed such a method using electron paramagnetic resonance (EPR) to make in vivo measurements of the maxillary incisors. This report provides evidence that the use of in vitro studies can provide data that are fully representative of the measurements made in vivo. This is necessary because, in order to systematically test and improve the reliability and accuracy of the dose estimates made with our EPR dosimetry system, it is important to conduct controlled studies in vitro using irradiated human teeth. Therefore, it is imperative to validate whether our in vitro models adequately simulate the measurements made in vivo, which are intended to help guide decisions on triage after a radiation event. Using a healthy volunteer with a dentition gap that allows using a partial denture, human teeth were serially irradiated in vitro and then, using a partial denture, placed in the volunteer's mouth for measurements. We compared dose estimates made using in vivo measurements made in the volunteer's mouth to measurements made on the same teeth in our complex mouth model that simulates electromagnetic and anatomic properties of the mouth. Our results demonstrate that this mouth model can be used in in vitro studies to develop the system because these measurements appropriately model in vivo conditions.
Collapse
Affiliation(s)
- Kyo Kobayashi
- EPR Center for the Study of Viable Systems, Radiology Department, Geisel School of Medicine at Dartmouth, HB 7785, Williamson Translational Research Bldg, Lebanon, NH, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Umakoshi M, Yamaguchi I, Hirata H, Kunugita N, Williams BB, Swartz HM, Miyake M. In Vivo Electron Paramagnetic Resonance Tooth Dosimetry: Dependence of Radiation-Induced Signal Amplitude on the Enamel Thickness and Surface Area of Ex Vivo Human Teeth. HEALTH PHYSICS 2017; 113:262-270. [PMID: 28796750 DOI: 10.1097/hp.0000000000000698] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In vivo L-band electron paramagnetic resonance tooth dosimetry is a newly developed and very promising method for retrospective biodosimetry in individuals who may have been exposed to significant levels of ionizing radiation. The present study aimed to determine the relationships among enamel thickness, enamel area, and measured electron paramagnetic resonance signal amplitude with a view to improve the quantitative accuracy of the dosimetry technique. Ten isolated incisors were irradiated using well-characterized doses, and their radiation-induced electron paramagnetic resonance signals were measured. Following the measurements, the enamel thickness and area of each tooth were measured using micro-focus computed tomography. Linear regression showed that the enamel area at each measurement position significantly affected the radiation-induced electron paramagnetic resonance signal amplitude (p < 0.001). Simulation data agreed well with this result. These results indicate that it is essential to properly consider enamel thickness and area when interpreting electron paramagnetic resonance tooth dosimetry measurements to optimize the accuracy of dose estimation.
Collapse
Affiliation(s)
- Michitaka Umakoshi
- *Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Kagawa University, Kagawa,761-0793, Japan; †Department of Environmental Health, National Institute of Public Health, Wako, 351-0197, Japan; ‡Division of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University, Sapporo, 060-0814, Japan; §EPR Center for the Study of Viable Systems, Department of Radiology, The Geisel School of Medicine at Dartmouth, Lebanon, NH 03766
| | | | | | | | | | | | | |
Collapse
|
10
|
Miyake M, Nakai Y, Yamaguchi I, Hirata H, Kunugita N, Williams BB, Swartz HM. IN-VIVO RADIATION DOSIMETRY USING PORTABLE L BAND EPR: ON-SITE MEASUREMENT OF VOLUNTEERS IN FUKUSHIMA PREFECTURE, JAPAN. RADIATION PROTECTION DOSIMETRY 2016; 172:248-253. [PMID: 27522046 PMCID: PMC5225973 DOI: 10.1093/rpd/ncw214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The aim of this study was to make direct measurements of the possible radiation-induced EPR signals in the teeth of volunteers who were residents in Fukushima within 80 km distance from the Fukushima Nuclear Power plant at the time of the disaster, and continued to live there for at least 3 month after the disaster. Thirty four volunteers were enrolled in this study. These measurements were made using a portable L-band EPR spectrometer, which was originally developed in the EPR Center at Dartmouth. All measurements were performed using surface loop resonators that have been specifically designed for the upper incisor teeth. Potentially these signals include not only radiation-induced signals induced by the incident but also background signals including those from prior radiation exposure from the environment and medical exposure. We demonstrated that it is feasible to transport the dosimeter to the measurement site and make valid measurements. The intensity of the signals that were obtained was not significantly above those seen in volunteers who had not had potential radiation exposures at Fukushima.
Collapse
Affiliation(s)
- Minoru Miyake
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Kagawa University, 750-1 Ikenobe, Miki-cho, Kita-gun , Kagawa Prefecture 761-0793, Japan
| | - Yasuhiro Nakai
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Kagawa University, 750-1 Ikenobe, Miki-cho, Kita-gun , Kagawa Prefecture 761-0793, Japan
| | - Ichiro Yamaguchi
- Department of Environmental Health, NIPH (National Institute of Public Health ), 2-3-6 Minami, Wako-shi , Saitama 351-0197, Japan
| | - Hiroshi Hirata
- EPR group in the Division of Bioengineering and Bioinformatics, Hokkaido University, Kita 14, Nishi 9, Kita-ku, Sapporo, Hokkaido 060-0814, Japan
| | - Naoki Kunugita
- Department of Environmental Health, NIPH (National Institute of Public Health ), 2-3-6 Minami, Wako-shi , Saitama 351-0197, Japan
| | - Benjamin B Williams
- Dartmouth EPR Center, Department of Radiology, The Geisel School of Medicine at Dartmouth, Lebanon, NH 03756, USA
| | - Harold M Swartz
- Dartmouth EPR Center, Department of Radiology, The Geisel School of Medicine at Dartmouth, Lebanon, NH 03756, USA
| |
Collapse
|
11
|
Guo J, Zou J, Dong G, Ma L, Cong J, Fan K, Yang G, Wu K. The Application and Distribution of Magnetic Field Modulation in the Detection Apertures of X-band EPR Cavities for In Vivo Tooth Dosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:103-111. [PMID: 27473705 PMCID: PMC5225977 DOI: 10.1093/rpd/ncw173] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In vivo electron paramagnetic resonance tooth dosimetry could be a practical and ideal tool for quick mass triage of victims in the rescue following a disaster event involving irradiation radiation. Magnetic field modulation is an important issue to improve the sensitivity of X-band in vivo tooth dosimetry. We designed a couple of trapezoidal modulation coil sets fixed on the magnet poles that could be used to apply sufficient magnet field modulation into the detection aperture of the resonant cavity. Measurements of irradiated teeth with such coil sets demonstrated significant radiation-induced signals. The modulation generation efficiencies and magnetic field distributions in apertures with different cavity geometries were analytically calculated, simulated by a finite element method and evaluated by measurements of a free radical point sample to study the influences caused by the geometries of the apertures and other factors.
Collapse
Affiliation(s)
- Junwang Guo
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| | - Jierui Zou
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| | - Guofu Dong
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| | - Lei Ma
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| | - Jianbo Cong
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| | - Kai Fan
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| | - Guoshan Yang
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| | - Ke Wu
- Beijing Key Laboratory of Radiation Biology (No. BZ0325), Beijing Institute of Radiation Medicine, No. 27 Tai Ping Road, Beijing, China
| |
Collapse
|
12
|
Gallez B. Contribution of Harold M. Swartz to In Vivo EPR and EPR Dosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:16-37. [PMID: 27421469 DOI: 10.1093/rpd/ncw157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In 2015, we are celebrating half a century of research in the application of Electron Paramagnetic Resonance (EPR) as a biodosimetry tool to evaluate the dose received by irradiated people. During the EPR Biodose 2015 meeting, a special session was organized to acknowledge the pioneering contribution of Harold M. (Hal) Swartz in the field. The article summarizes his main contribution in physiology and medicine. Four emerging themes have been pursued continuously along his career since its beginning: (1) radiation biology; (2) oxygen and oxidation; (3) measuring physiology in vivo; and (4) application of these measurements in clinical medicine. The common feature among all these different subjects has been the use of magnetic resonance techniques, especially EPR. In this article, you will find an impressionist portrait of Hal Swartz with the description of the 'making of' this pioneer, a time-line perspective on his career with the creation of three National Institutes of Health-funded EPR centers, a topic-oriented perspective on his career with a description of his major contributions to Science, his role as a mentor and his influence on his academic children, his active role as founder of scientific societies and organizer of scientific meetings, and the well-deserved international recognition received so far.
Collapse
Affiliation(s)
- Bernard Gallez
- Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Avenue Mounier 73.08, B-1200, Brussels, Belgium
| |
Collapse
|
13
|
Desmet CM, Levêque P, Gallez B. Factors Affecting the Quality of Tooth Enamel for In Vivo EPR-Based Retrospective Biodosimetry. RADIATION PROTECTION DOSIMETRY 2016; 172:96-102. [PMID: 27473693 PMCID: PMC5225974 DOI: 10.1093/rpd/ncw212] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In vivo electron paramagnetic resonance biodosimetry on tooth enamel is likely to be an important technology for triage of overexposed individuals after a major radiological incident. The accuracy and robustness of the technique relies on various properties of the enamel such as the geometry of the tooth, the presence of restorations, whitening treatments or exposition to sunlight. Those factors are reviewed, and their influence on dosimetry specifically for triage purposes is discussed.
Collapse
Affiliation(s)
- Céline M Desmet
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| | - Philippe Levêque
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université Catholique de Louvain, Avenue Mounier 73 - B1.73.08, B-1200 Brussels, Belgium
| |
Collapse
|
14
|
Schreiber W, Petryakov SV, Kmiec MM, Feldman MA, Meaney PM, Wood VA, Boyle HK, Flood AB, Williams BB, Swartz HM. FLEXIBLE, WIRELESS, INDUCTIVELY COUPLED SURFACE COIL RESONATOR FOR EPR TOOTH DOSIMETRY. RADIATION PROTECTION DOSIMETRY 2016; 172:87-95. [PMID: 27421470 PMCID: PMC6287419 DOI: 10.1093/rpd/ncw153] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a viable method to accurately estimate the amount of ionizing radiation to which an individual has been exposed. In the intended measurement conditions and scenario, it is essential that the measurement process be fast, straightforward and provides meaningful and accurate dose estimations for individuals in the expected measurement conditions. The sensing component of a conventional L-band EPR spectrometer used for tooth dosimetry typically consists of a surface coil resonator that is rigidly, physically attached to the coupler. This design can result in cumbersome operation, limitations in teeth geometries that may be measured and hinder the overall utility of the dosimeter. A novel surface coil resonator has been developed for the currently existing L-band (1.15 GHz) EPR tooth dosimeter for the intended use as a point of care device by minimally trained operators. This resonator development provides further utility to the dosimeter, and increases the usability of the dosimeter by non-expert operators in the intended use scenario.
Collapse
Affiliation(s)
- Wilson Schreiber
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Sergey V Petryakov
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Maciej M Kmiec
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Matthew A Feldman
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Paul M Meaney
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
- Thayer School of Engineering at Dartmouth, Hanover, NH 03755, USA
| | - Victoria A Wood
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Holly K Boyle
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Ann Barry Flood
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Benjamin B Williams
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| | - Harold M Swartz
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA
| |
Collapse
|
15
|
Sproull M, Camphausen K. State-of-the-Art Advances in Radiation Biodosimetry for Mass Casualty Events Involving Radiation Exposure. Radiat Res 2016; 186:423-435. [PMID: 27710702 DOI: 10.1667/rr14452.1] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
With the possibility of large-scale terrorist attacks around the world, the need for modeling and development of new medical countermeasures for potential future chemical, biological, radiological and nuclear (CBRN) has been well established. Project Bioshield, initiated in 2004, provided a framework to develop and expedite research in the field of CBRN exposures. To respond to large-scale population exposures from a nuclear event or radiation dispersal device (RDD), new methods for determining received dose using biological modeling became necessary. The field of biodosimetry has advanced significantly beyond this original initiative, with expansion into the fields of genomics, proteomics, metabolomics and transcriptomics. Studies are ongoing to evaluate the use of lymphocyte kinetics for dose assessment, as well as the development of field-deployable EPR technology. In addition, expansion of traditional cytogenetic assessment methods through the use of automated platforms and the development of laboratory surge capacity networks have helped to advance our biodefense preparedness. In this review of the latest advances in the field of biodosimetry we evaluate our progress and identify areas that still need to be addressed to achieve true field-deployment readiness.
Collapse
Affiliation(s)
- Mary Sproull
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| | - Kevin Camphausen
- Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland
| |
Collapse
|
16
|
Desmet CM, Djurkin A, Dos Santos-Goncalvez AM, Dong R, Kmiec MM, Kobayashi K, Rychert K, Beun S, Leprince JG, Leloup G, Levêque P, Gallez B. Tooth Retrospective Dosimetry Using Electron Paramagnetic Resonance: Influence of Irradiated Dental Composites. PLoS One 2015; 10:e0131913. [PMID: 26125565 PMCID: PMC4488324 DOI: 10.1371/journal.pone.0131913] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 06/08/2015] [Indexed: 11/25/2022] Open
Abstract
In the aftermath of a major radiological accident, the medical management of overexposed individuals will rely on the determination of the dose of ionizing radiations absorbed by the victims. Because people in the general population do not possess conventional dosimeters, after the fact dose reconstruction methods are needed. Free radicals are induced by radiations in the tooth enamel of victims, in direct proportion to dose, and can be quantified using Electron Paramagnetic Resonance (EPR) spectrometry, a technique that was demonstrated to be very appropriate for mass triage. The presence of dimethacrylate based restorations on teeth can interfere with the dosimetric signal from the enamel, as free radicals could also be induced in the various composites used. The aim of the present study was to screen irradiated composites for a possible radiation-induced EPR signal, to characterize it, and evaluate a possible interference with the dosimetric signal of the enamel. We investigated the most common commercial composites, and experimental compositions, for a possible class effect. The effect of the dose was studied between 10 Gy and 100 Gy using high sensitivity X-band spectrometer. The influence of this radiation-induced signal from the composite on the dosimetric signal of the enamel was also investigated using a clinical L-Band EPR spectrometer, specifically developed in the EPR center at Dartmouth College. In X-band, a radiation-induced signal was observed for high doses (25-100 Gy); it was rapidly decaying, and not detected after only 24h post irradiation. At 10 Gy, the signal was in most cases not measurable in the commercial composites tested, with the exception of 3 composites showing a significant intensity. In L-band study, only one irradiated commercial composite influenced significantly the dosimetric signal of the tooth, with an overestimation about 30%. In conclusion, the presence of the radiation-induced signal from dental composites should not significantly influence the dosimetry for early dose assessment.
Collapse
Affiliation(s)
- Céline M. Desmet
- Biomedical Magnetic Resonance Research group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | - Andrej Djurkin
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium
| | - Ana Maria Dos Santos-Goncalvez
- Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | - Ruhong Dong
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Maciej M. Kmiec
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Kyo Kobayashi
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Kevin Rychert
- EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, United States of America
| | - Sébastien Beun
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium
| | - Julian G. Leprince
- Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
| | - Gaëtane Leloup
- Advanced Drug Delivery and Biomaterials Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
| | - Philippe Levêque
- Biomedical Magnetic Resonance Research group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Research group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
- * E-mail:
| |
Collapse
|
17
|
Rychert KM, Zhu G, Kmiec MM, Nemani VK, Williams BB, Flood AB, Swartz HM, Gimi B. Imaging tooth enamel using zero echo time (ZTE) magnetic resonance imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2015; 9417:94171I. [PMID: 25914509 PMCID: PMC4405678 DOI: 10.1117/12.2083995] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
In an event where many thousands of people may have been exposed to levels of radiation that are sufficient to cause the acute radiation syndrome, we need technology that can estimate the absorbed dose on an individual basis for triage and meaningful medical decision making. Such dose estimates may be achieved using in vivo electron paramagnetic resonance (EPR) tooth biodosimetry, which measures the number of persistent free radicals that are generated in tooth enamel following irradiation. However, the accuracy of dose estimates may be impacted by individual variations in teeth, especially the amount and distribution of enamel in the inhomogeneous sensitive volume of the resonator used to detect the radicals. In order to study the relationship between interpersonal variations in enamel and EPR-based dose estimates, it is desirable to estimate these parameters nondestructively and without adding radiation to the teeth. Magnetic Resonance Imaging (MRI) is capable of acquiring structural and biochemical information without imparting additional radiation, which may be beneficial for many EPR dosimetry studies. However, the extremely short T2 relaxation time in tooth structures precludes tooth imaging using conventional MRI methods. Therefore, we used zero echo time (ZTE) MRI to image teeth ex vivo to assess enamel volumes and spatial distributions. Using these data in combination with the data on the distribution of the transverse radio frequency magnetic field from electromagnetic simulations, we then can identify possible sources of variations in radiation-induced signals detectable by EPR. Unlike conventional MRI, ZTE applies spatial encoding gradients during the RF excitation pulse, thereby facilitating signal acquisition almost immediately after excitation, minimizing signal loss from short T2 relaxation times. ZTE successfully provided volumetric measures of tooth enamel that may be related to variations that impact EPR dosimetry and facilitate the development of analytical procedures for individual dose estimates.
Collapse
Affiliation(s)
- Kevin M. Rychert
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Gang Zhu
- MRI Division, Bruker BioSpin Corporation, 15 Fortune Drive, Billerica, MA 01821
| | - Maciej M. Kmiec
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Venkata K. Nemani
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Benjamin B. Williams
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Ann Barry Flood
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Harold M. Swartz
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| | - Barjor Gimi
- Department of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH 03755
| |
Collapse
|
18
|
Woflson H, Ahmad R, Twig Y, Williams B, Blank A. A magnetic resonance probehead for evaluating the level of ionizing radiation absorbed in human teeth. HEALTH PHYSICS 2015; 108:326-335. [PMID: 25627944 DOI: 10.1097/hp.0000000000000187] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A miniature electron spin resonance (ESR) probehead that includes a static field source and a microwave resonator for in vivo measurement of paramagnetic defects in tooth enamel was developed. These defects are known to be a good marker for quantifying the ionizing radiation dose absorbed in teeth. The probehead has a typical length of just 30 mm and total weight of 220 g. The patient "bites" into the probehead while the measurement procedure is being carried out. The probehead operates in pulsed mode at a frequency of ∼ 11.2 GHz and supplies a static magnetic field of ∼ 400 mT. A detailed design of the probehead is provided together with its specifications in terms of measurement volume and signal-to-noise ratio for a typical sample. A specially developed simulation program was used to predict the spatial distribution of the acquired signal under conditions of grossly inhomogeneous static and RF fields. Experimental results with irradiated incisor teeth validated the probehead's sensitivity, being able to detect signals in tooth irradiated by only 2 Gy. Subject to additional improvements and tests, this type of probehead can potentially have significant clinical applications ranging from mass triage following major nuclear events to routine occupational evaluation of ionizing radiation absorbed over long periods of time.
Collapse
Affiliation(s)
- Helen Woflson
- *Schulich Faculty of Chemistry, Technion-Israel Institute of Technology, Haifa 32000, Israel; †Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, 43210; ‡The Geisel School of Medicine at Dartmouth, Departments of Medicine and Radiology, Lebanon, NH 03766
| | | | | | | | | |
Collapse
|
19
|
New developed cylindrical TM010 mode EPR cavity for X-band in vivo tooth dosimetry. PLoS One 2014; 9:e106587. [PMID: 25222483 PMCID: PMC4164439 DOI: 10.1371/journal.pone.0106587] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 07/30/2014] [Indexed: 11/20/2022] Open
Abstract
EPR tooth in vivo dosimetry is an attractive approach for initial triage after unexpected nuclear events. An X-band cylindrical TM010 mode resonant cavity was developed for in vivo tooth dosimetry and used in EPR applications for the first time. The cavity had a trapezoidal measuring aperture at the exact position of the cavity's cylindrical wall where strong microwave magnetic field H1 concentrated and weak microwave electric field E1 distributed. Theoretical calculations and simulations were used to design and optimize the cavity parameters. The cavity features were evaluated by measuring DPPH sample, intact incisor samples embed in a gum model and the rhesus monkey teeth. The results showed that the cavity worked at designed frequency and had the ability to make EPR spectroscopy in relative high sensitivity. Sufficient modulation amplitude and microwave power could be applied into the aperture. Radiation induced EPR signal could be observed remarkably from 1 Gy irradiated intact incisor within only 30 seconds, which was among the best in scan time and detection limit. The in vivo spectroscopy was also realized by acquiring the radiation induced EPR signal from teeth of rhesus monkey whose teeth was irradiated by dose of 2 Gy. The results suggested that the cavity was sensitive to meet the demand to assess doses of significant level in short time. This cavity provided a very potential option for the development of X-band in vivo dosimetry.
Collapse
|
20
|
Flood AB, Boyle HK, Du G, Demidenko E, Nicolalde RJ, Williams BB, Swartz HM. Advances in a framework to compare bio-dosimetry methods for triage in large-scale radiation events. RADIATION PROTECTION DOSIMETRY 2014; 159:77-86. [PMID: 24729594 PMCID: PMC4067227 DOI: 10.1093/rpd/ncu120] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Planning and preparation for a large-scale nuclear event would be advanced by assessing the applicability of potentially available bio-dosimetry methods. Using an updated comparative framework the performance of six bio-dosimetry methods was compared for five different population sizes (100-1,000,000) and two rates for initiating processing of the marker (15 or 15,000 people per hour) with four additional time windows. These updated factors are extrinsic to the bio-dosimetry methods themselves but have direct effects on each method's ability to begin processing individuals and the size of the population that can be accommodated. The results indicate that increased population size, along with severely compromised infrastructure, increases the time needed to triage, which decreases the usefulness of many time intensive dosimetry methods. This framework and model for evaluating bio-dosimetry provides important information for policy-makers and response planners to facilitate evaluation of each method and should advance coordination of these methods into effective triage plans.
Collapse
Affiliation(s)
- Ann Barry Flood
- Geisel School of Medicine at Dartmouth, EPR Center, Hanover, NH 03768, USA
| | - Holly K Boyle
- Geisel School of Medicine at Dartmouth, EPR Center, Hanover, NH 03768, USA
| | - Gaixin Du
- Geisel School of Medicine at Dartmouth, EPR Center, Hanover, NH 03768, USA
| | - Eugene Demidenko
- Geisel School of Medicine at Dartmouth, EPR Center, Hanover, NH 03768, USA
| | | | | | - Harold M Swartz
- Geisel School of Medicine at Dartmouth, EPR Center, Hanover, NH 03768, USA
| |
Collapse
|
21
|
Williams BB, Flood AB, Salikhov I, Kobayashi K, Dong R, Rychert K, Du G, Schreiber W, Swartz HM. In vivo EPR tooth dosimetry for triage after a radiation event involving large populations. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:335-46. [PMID: 24711003 PMCID: PMC11064839 DOI: 10.1007/s00411-014-0534-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Accepted: 02/27/2014] [Indexed: 05/26/2023]
Abstract
The management of radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation will rely critically on the availability and use of suitable biodosimetry methods. In vivo electron paramagnetic resonance (EPR) tooth dosimetry has a number of valuable and unique characteristics and capabilities that may help enable effective triage. We have produced a prototype of a deployable EPR tooth dosimeter and tested it in several in vitro and in vivo studies to characterize the performance and utility at the state of the art. This report focuses on recent advances in the technology, which strengthen the evidence that in vivo EPR tooth dosimetry can provide practical, accurate, and rapid measurements in the context of its intended use to help triage victims in the event of an improvised nuclear device. These advances provide evidence that the signal is stable, accurate to within 0.5 Gy, and can be successfully carried out in vivo. The stability over time of the radiation-induced EPR signal from whole teeth was measured to confirm its long-term stability and better characterize signal behavior in the hours following irradiation. Dosimetry measurements were taken for five pairs of natural human upper central incisors mounted within a simple anatomic mouth model that demonstrates the ability to achieve 0.5 Gy standard error of inverse dose prediction. An assessment of the use of intact upper incisors for dose estimation and screening was performed with volunteer subjects who have not been exposed to significant levels of ionizing radiation and patients who have undergone total body irradiation as part of bone marrow transplant procedures. Based on these and previous evaluations of the performance and use of the in vivo tooth dosimetry system, it is concluded that this system could be a very valuable resource to aid in the management of a massive radiological event.
Collapse
Affiliation(s)
- Benjamin B Williams
- Department of Radiology, EPR Center for the Study of Viable Systems, Geisel School of Medicine at Dartmouth, Hanover, NH, USA,
| | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Tucker JD, Joiner MC, Thomas RA, Grever WE, Bakhmutsky MV, Chinkhota CN, Smolinski JM, Divine GW, Auner GW. Accurate Gene Expression-Based Biodosimetry Using a Minimal Set of Human Gene Transcripts. Int J Radiat Oncol Biol Phys 2014; 88:933-9. [DOI: 10.1016/j.ijrobp.2013.11.248] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 11/26/2013] [Accepted: 11/30/2013] [Indexed: 10/25/2022]
|
23
|
Swartz HM, Williams BB, Zaki BI, Hartford AC, Jarvis LA, Chen EY, Comi RJ, Ernstoff MS, Hou H, Khan N, Swarts SG, Flood AB, Kuppusamy P. Clinical EPR: unique opportunities and some challenges. Acad Radiol 2014; 21:197-206. [PMID: 24439333 DOI: 10.1016/j.acra.2013.10.011] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/03/2013] [Accepted: 10/14/2013] [Indexed: 11/29/2022]
Abstract
Electron paramagnetic resonance (EPR) spectroscopy has been well established as a viable technique for measurement of free radicals and oxygen in biological systems, from in vitro cellular systems to in vivo small animal models of disease. However, the use of EPR in human subjects in the clinical setting, although attractive for a variety of important applications such as oxygen measurement, is challenged with several factors including the need for instrumentation customized for human subjects, probe, and regulatory constraints. This article describes the rationale and development of the first clinical EPR systems for two important clinical applications, namely, measurement of tissue oxygen (oximetry) and radiation dose (dosimetry) in humans. The clinical spectrometers operate at 1.2 GHz frequency and use surface-loop resonators capable of providing topical measurements up to 1 cm depth in tissues. Tissue pO2 measurements can be carried out noninvasively and repeatedly after placement of an oxygen-sensitive paramagnetic material (currently India ink) at the site of interest. Our EPR dosimetry system is capable of measuring radiation-induced free radicals in the tooth of irradiated human subjects to determine the exposure dose. These developments offer potential opportunities for clinical dosimetry and oximetry, which include guiding therapy for individual patients with tumors or vascular disease by monitoring of tissue oxygenation. Further work is in progress to translate this unique technology to routine clinical practice.
Collapse
Affiliation(s)
- Harold M Swartz
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766.
| | - Benjamin B Williams
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Bassem I Zaki
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Alan C Hartford
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Lesley A Jarvis
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Eunice Y Chen
- Department of Surgery, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Richard J Comi
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Marc S Ernstoff
- Department of Medicine, Geisel School of Medicine at Dartmouth, Dartmouth College, Hanover, NH
| | - Huagang Hou
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Nadeem Khan
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Steven G Swarts
- Dept. of Radiation Oncology, University of Florida, Gainesville, FL
| | - Ann B Flood
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| | - Periannan Kuppusamy
- Department of Radiology, Geisel School of Medicine at Dartmouth, Dartmouth College, 48 Lafayette Street, Lebanon, NH 03766
| |
Collapse
|
24
|
Tucker JD, Divine GW, Grever WE, Thomas RA, Joiner MC, Smolinski JM, Auner GW. Gene expression-based dosimetry by dose and time in mice following acute radiation exposure. PLoS One 2013; 8:e83390. [PMID: 24358280 PMCID: PMC3865163 DOI: 10.1371/journal.pone.0083390] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2013] [Accepted: 11/04/2013] [Indexed: 11/19/2022] Open
Abstract
Rapid and reliable methods for performing biological dosimetry are of paramount importance in the event of a large-scale nuclear event. Traditional dosimetry approaches lack the requisite rapid assessment capability, ease of use, portability and low cost, which are factors needed for triaging a large number of victims. Here we describe the results of experiments in which mice were acutely exposed to (60)Co gamma rays at doses of 0 (control) to 10 Gy. Blood was obtained from irradiated mice 0.5, 1, 2, 3, 5, and 7 days after exposure. mRNA expression levels of 106 selected genes were obtained by reverse-transcription real time PCR. Stepwise regression of dose received against individual gene transcript expression levels provided optimal dosimetry at each time point. The results indicate that only 4-7 different gene transcripts are needed to explain ≥ 0.69 of the variance (R(2)), and that receiver-operator characteristics, a measure of sensitivity and specificity, of ≥ 0.93 for these statistical models were achieved at each time point. These models provide an excellent description of the relationship between the actual and predicted doses up to 6 Gy. At doses of 8 and 10 Gy there appears to be saturation of the radiation-response signals with a corresponding diminution of accuracy. These results suggest that similar analyses in humans may be advantageous for use in a field-portable device designed to assess exposures in mass casualty situations.
Collapse
Affiliation(s)
- James D. Tucker
- Department of Biological Sciences, Wayne State University, Detroit, Michigan, United States of America
| | - George W. Divine
- Department of Public Health Sciences, Henry Ford Hospital, Detroit, Michigan, United States of America
| | - William E. Grever
- Department of Biological Sciences, Wayne State University, Detroit, Michigan, United States of America
| | - Robert A. Thomas
- Department of Biological Sciences, Wayne State University, Detroit, Michigan, United States of America
| | - Michael C. Joiner
- Department of Radiation Oncology, Wayne State University, Detroit, Michigan, United States of America
| | - Joseph M. Smolinski
- Department of Electrical and Computer Engineering, Wayne State University, Detroit, Michigan, United States of America
| | - Gregory W. Auner
- Department of Electrical and Computer Engineering, Wayne State University, Detroit, Michigan, United States of America
| |
Collapse
|
25
|
Sullivan JM, Prasanna PGS, Grace MB, Wathen L, Wallace RL, Koerner JF, Coleman CN. Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations. HEALTH PHYSICS 2013; 105:540-54. [PMID: 24162058 PMCID: PMC3810609 DOI: 10.1097/hp.0b013e31829cf221] [Citation(s) in RCA: 144] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Following a mass-casualty nuclear disaster, effective medical triage has the potential to save tens of thousands of lives. In order to best use the available scarce resources, there is an urgent need for biodosimetry tools to determine an individual's radiation dose. Initial triage for radiation exposure will include location during the incident, symptoms, and physical examination. Stepwise triage will include point of care assessment of less than or greater than 2 Gy, followed by secondary assessment, possibly with high throughput screening, to further define an individual's dose. Given the multisystem nature of radiation injury, it is unlikely that any single biodosimetry assay can be used as a standalone tool to meet the surge in capacity with the timeliness and accuracy needed. As part of the national preparedness and planning for a nuclear or radiological incident, the authors reviewed the primary literature to determine the capabilities and limitations of a number of biodosimetry assays currently available or under development for use in the initial and secondary triage of patients. Understanding the requirements from a response standpoint and the capability and logistics for the various assays will help inform future biodosimetry technology development and acquisition. Factors considered include: type of sample required, dose detection limit, time interval when the assay is feasible biologically, time for sample preparation and analysis, ease of use, logistical requirements, potential throughput, point-of-care capability, and the ability to support patient diagnosis and treatment within a therapeutically relevant time point.
Collapse
Affiliation(s)
- Julie M. Sullivan
- Office of Preparedness and Emergency Operations, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
- AAAS Science and Technology Policy Fellow, Washington DC
| | - Pataje G. S. Prasanna
- Radia on Research Program, Division of Cancer Treatment and Diagnosis, National Cancer Institute, Bethesda, MD
| | - Marcy B. Grace
- Biomedical Advanced Research & Development Authority, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - Lynne Wathen
- Biomedical Advanced Research & Development Authority, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - Rodney L. Wallace
- Biomedical Advanced Research & Development Authority, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - John F. Koerner
- Office of Preparedness and Emergency Operations, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
| | - C. Norman Coleman
- Office of Preparedness and Emergency Operations, Office of the Assistant Secretary for Preparedness and Response, Department of Health and Human Services, Washington, DC
- Radia on Research Program, Division of Cancer Treatment and Diagnosis, National Cancer Institute, Bethesda, MD
| |
Collapse
|
26
|
Levêque P, Desmet C, Dos Santos-Goncalvez AM, Beun S, Leprince JG, Leloup G, Gallez B. Influence of free radicals signal from dental resins on the radio-induced signal in teeth in EPR retrospective dosimetry. PLoS One 2013; 8:e62225. [PMID: 23704875 PMCID: PMC3660527 DOI: 10.1371/journal.pone.0062225] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Accepted: 03/19/2013] [Indexed: 11/27/2022] Open
Abstract
In case of radiological accident, retrospective dosimetry is needed to reconstruct the absorbed dose of overexposed individuals not wearing personal dosimeters at the onset of the incident. In such a situation, emergency mass triage will be required. In this context, it has been shown that Electron Paramagnetic Resonance (EPR) spectroscopy would be a rapid and sensitive method, on the field deployable system, allowing dose evaluation of a great number of people in a short time period. This methodology uses tooth enamel as a natural dosimeter. Ionising radiations create stable free radicals in the enamel, in a dose dependent manner, which can be detected by EPR directly in the mouth with an appropriate resonator. Teeth are often subject to restorations, currently made of synthetic dimethacrylate-based photopolymerizable composites. It is known that some dental composites give an EPR signal which is likely to interfere with the dosimetric signal from the enamel. So far, no information was available about the occurrence of this signal in the various composites available on the market, the magnitude of the signal compared to the dosimetric signal, nor its evolution with time. In this study, we conducted a systematic characterization of the signal (intensity, kinetics, interference with dosimetric signal) on 19 most widely used composites for tooth restoration, and on 14 experimental resins made with the most characteristic monomers found in commercial composites. Although a strong EPR signal was observed in every material, a rapid decay of the signal was noted. Six months after the polymerization, the signal was negligible in most composites compared to a 3 Gy dosimetric signal in a tooth. In some cases, a stable atypical signal was observed, which was still interfering with the dosimetric signal.
Collapse
Affiliation(s)
- Philippe Levêque
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
| | - Céline Desmet
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
| | | | - Sébastien Beun
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium
| | - Julian G. Leprince
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
- Institute of Condensed Matter and Nanosciences, Bio- and Soft- Matter, Université catholique de Louvain, Louvain-la-Neuve, Belgium
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium
| | - Gaëtane Leloup
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
- Institute of Condensed Matter and Nanosciences, Bio- and Soft- Matter, Université catholique de Louvain, Louvain-la-Neuve, Belgium
- School of Dentistry and Stomatology, Université catholique de Louvain, Brussels, Belgium
| | - Bernard Gallez
- Biomedical Magnetic Resonance Research Group, Louvain Drug Research Institute, Université catholique de Louvain, Brussels, Belgium
- Center for Research and Engineering on Biomaterials CRIBIO, Université catholique de Louvain, Brussels, Belgium
- * E-mail:
| |
Collapse
|
27
|
Omaruddin RA, Roland TA, Wallace HJ, Chaudhry MA. Gene expression as a biomarker for human radiation exposure. Hum Cell 2013; 26:2-7. [PMID: 23446844 DOI: 10.1007/s13577-013-0059-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2012] [Accepted: 01/10/2013] [Indexed: 11/25/2022]
Abstract
Accidental exposure to ionizing radiation can be unforeseen, rapid, and devastating. The detonation of a radiological device leading to such an exposure can be detrimental to the exposed population. The radiation-induced damage may manifest as acute effects that can be detected clinically or may be more subtle effects that can lead to long-term radiation-induced abnormalities. Accurate identification of the individuals exposed to radiation is challenging. The availability of a rapid and effective screening test that could be used as a biomarker of radiation exposure detection is mandatory. We tested the suitability of alterations in gene expression to serve as a biomarker of human radiation exposure. To develop a useful gene expression biomonitor, however, gene expression changes occurring in response to irradiation in vivo must be measured directly. Patients undergoing radiation therapy provide a suitable test population for this purpose. We examined the expression of CC3, MADH7, and SEC PRO in blood samples of these patients before and after radiotherapy to measure the in vivo response. The gene expression after ionizing radiation treatment varied among different patients, suggesting the complexity of the response. The expression of the SEC PRO gene was repressed in most of the patients. The MADH7 gene was found to be upregulated in most of the subjects and could serve as a molecular marker of radiation exposure.
Collapse
Affiliation(s)
- Romaica A Omaruddin
- Department of Medical Laboratory and Radiation Sciences, University of Vermont, 302 Rowell Building, Burlington, VT 05405, USA
| | | | | | | |
Collapse
|
28
|
Demidenko E, Williams BB, Flood AB, Swartz HM. Standard error of inverse prediction for dose-response relationship: approximate and exact statistical inference. Stat Med 2012; 32:2048-61. [PMID: 23124816 DOI: 10.1002/sim.5668] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2012] [Accepted: 10/01/2012] [Indexed: 11/12/2022]
Abstract
This paper develops a new metric, the standard error of inverse prediction (SEIP), for a dose-response relationship (calibration curve) when dose is estimated from response via inverse regression. SEIP can be viewed as a generalization of the coefficient of variation to regression problem when x is predicted using y-value. We employ nonstandard statistical methods to treat the inverse prediction, which has an infinite mean and variance due to the presence of a normally distributed variable in the denominator. We develop confidence intervals and hypothesis testing for SEIP on the basis of the normal approximation and using the exact statistical inference based on the noncentral t-distribution. We derive the power functions for both approaches and test them via statistical simulations. The theoretical SEIP, as the ratio of the regression standard error to the slope, is viewed as reciprocal of the signal-to-noise ratio, a popular measure of signal processing. The SEIP, as a figure of merit for inverse prediction, can be used for comparison of calibration curves with different dependent variables and slopes. We illustrate our theory with electron paramagnetic resonance tooth dosimetry for a rapid estimation of the radiation dose received in the event of nuclear terrorism.
Collapse
Affiliation(s)
- Eugene Demidenko
- Dartmouth Physically Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR), Geisel School of Medicine at Dartmouth, Hanover, NH 03755, USA.
| | | | | | | |
Collapse
|
29
|
Pernot E, Hall J, Baatout S, Benotmane MA, Blanchardon E, Bouffler S, El Saghire H, Gomolka M, Guertler A, Harms-Ringdahl M, Jeggo P, Kreuzer M, Laurier D, Lindholm C, Mkacher R, Quintens R, Rothkamm K, Sabatier L, Tapio S, de Vathaire F, Cardis E. Ionizing radiation biomarkers for potential use in epidemiological studies. MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH 2012; 751:258-286. [DOI: 10.1016/j.mrrev.2012.05.003] [Citation(s) in RCA: 135] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2012] [Revised: 05/04/2012] [Accepted: 05/28/2012] [Indexed: 02/07/2023]
|
30
|
Swartz HM, Flood AB, Williams BB, Dong R, Swarts SG, He X, Grinberg O, Sidabras J, Demidenko E, Gui J, Gladstone DJ, Jarvis LA, Kmiec MM, Kobayashi K, Lesniewski PN, Marsh SDP, Matthews TP, Nicolalde RJ, Pennington PM, Raynolds T, Salikhov I, Wilcox DE, Zaki BI. Electron paramagnetic resonance dosimetry for a large-scale radiation incident. HEALTH PHYSICS 2012; 103:255-67. [PMID: 22850230 PMCID: PMC3649772 DOI: 10.1097/hp.0b013e3182588d92] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
With possibilities for radiation terrorism and intensified concerns about nuclear accidents since the recent Fukushima Daiichi event, the potential exposure of large numbers of individuals to radiation that could lead to acute clinical effects has become a major concern. For the medical community to cope with such an event and avoid overwhelming the medical care system, it is essential to identify not only individuals who have received clinically significant exposures and need medical intervention but also those who do not need treatment. The ability of electron paramagnetic resonance to measure radiation-induced paramagnetic species, which persist in certain tissues (e.g., teeth, fingernails, toenails, bone, and hair), has led to this technique becoming a prominent method for screening significantly exposed individuals. Although the technical requirements needed to develop this method for effective application in a radiation event are daunting, remarkable progress has been made. In collaboration with General Electric and through funding committed by the Biomedical Advanced Research and Development Authority, electron paramagnetic resonance tooth dosimetry of the upper incisors is being developed to become a Food and Drug Administration-approved and manufacturable device designed to carry out triage for a threshold dose of 2 Gy. Significant progress has also been made in the development of electron paramagnetic resonance nail dosimetry based on measurements of nails in situ under point-of-care conditions, and in the near future this may become a second field-ready technique. Based on recent progress in measurements of nail clippings, it is anticipated that this technique may be implementable at remotely located laboratories to provide additional information when the measurements of dose on-site need to be supplemented. The authors conclude that electron paramagnetic resonance dosimetry is likely to be a useful part of triage for a large-scale radiation incident.
Collapse
|