1
|
Amin N, Foster T, Hossain MI, Hasan MR, Sarkar S, Rahman A, Adnan SD, Rahman M, Willetts J. Inadequate sanitation in healthcare facilities: A comprehensive evaluation of toilets in major hospitals in Dhaka, Bangladesh. PLoS One 2024; 19:e0295879. [PMID: 38776266 PMCID: PMC11111017 DOI: 10.1371/journal.pone.0295879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 04/15/2024] [Indexed: 05/24/2024] Open
Abstract
BACKGROUND Lack of access to functional and hygienic toilets in healthcare facilities (HCFs) is a significant public health issue in low- and middle-income countries (LMICs), leading to the transmission of infectious diseases. Globally, there is a lack of studies characterising toilet conditions and estimating user-to-toilet ratios in large urban hospitals in LMICs. We conducted a cross-sectional study in 10-government and two-private hospitals to explore the availability, functionality, cleanliness, and user-to-toilet ratio in Dhaka, Bangladesh. METHODS From Aug-Dec 2022, we undertook infrastructure assessments of toilets in selected hospitals. We observed all toilets and recorded attributes of intended users, including sex, disability status, patient status (in-patient/out-patient/caregiver) and/or staff (doctor/nurse/cleaner/mixed-gender/shared). Toilet functionality was defined according to criteria used by the WHO/UNICEF Joint-Monitoring Programme in HCFs. Toilet cleanliness was assessed, considering visible feces on any surface, strong fecal odor, presence of flies, sputum, insects, and rodents, and solid waste. RESULTS Amongst 2875 toilets, 2459 (86%) were observed. Sixty-eight-percent of government hospital toilets and 92% of private hospital toilets were functional. Only 33% of toilets in government hospitals and 56% in private hospitals were clean. A high user-to-toilet ratio was observed in government hospitals' outpatients service (214:1) compared to inpatients service (17:1). User-to-toilet ratio was also high in private hospitals' outpatients service (94:1) compared to inpatients wards (19:1). Only 3% of toilets had bins for menstrual-pad disposal and <1% of toilets had facilities for disabled people. CONCLUSION A high percentage of unclean toilets coupled with high user-to-toilet ratio hinders the achievement of SDG by 2030 and risks poor infection-control. Increasing the number of usable, clean toilets in proportion to users is crucial. The findings suggest an urgent call for attention to ensure basic sanitation facilities in Dhaka's HCFs. The policy makers should allocate resources for adequate toilets, maintenance staff, cleanliness, along with strong leadership of the hospital administrators.
Collapse
Affiliation(s)
- Nuhu Amin
- Institute for Sustainable Futures, University of Technology Sydney, Ultimo, NSW, Australia
- Health System and Population Studies Division, Environmental Health and WASH, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, Bangladesh
| | - Tim Foster
- Institute for Sustainable Futures, University of Technology Sydney, Ultimo, NSW, Australia
| | - Md. Imam Hossain
- Health System and Population Studies Division, Environmental Health and WASH, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, Bangladesh
| | - Md Rezaul Hasan
- Health System and Population Studies Division, Environmental Health and WASH, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, Bangladesh
| | - Supriya Sarkar
- Hospital Services Management, Directorate General of Health Services (DGHS), MoH&FW, Mohakhali, Dhaka, Bangladesh
| | - Aninda Rahman
- Communicable Disease Control (CDC) Program, Directorate General of Health Services (DGHS), MoH&FW, Mohakhali, Dhaka, Bangladesh
| | - Shaikh Daud Adnan
- Hospital Services Management, Directorate General of Health Services (DGHS), MoH&FW, Mohakhali, Dhaka, Bangladesh
| | - Mahbubur Rahman
- Health System and Population Studies Division, Environmental Health and WASH, International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, Bangladesh
| | - Juliet Willetts
- Institute for Sustainable Futures, University of Technology Sydney, Ultimo, NSW, Australia
| |
Collapse
|
2
|
Paddy EN, Afolabi OOD, Sohail M. Exploring toilet plume bioaerosol exposure dynamics in public toilets using a Design of Experiments approach. Sci Rep 2024; 14:10665. [PMID: 38724540 PMCID: PMC11082142 DOI: 10.1038/s41598-024-61039-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 04/30/2024] [Indexed: 05/12/2024] Open
Abstract
Bioaerosols generated during toilet flushing can contribute to the spread of airborne pathogens and cross-contamination in indoor environments. This presents an increased risk of fomite-mediated or aerosol disease transmission. This study systematically investigated the factors contributing to increased bioaerosol exposure following toilet flushing and developed an empirical model for predicting the exposure-relevant bioaerosol concentration. Air in a toilet cubicle was sampled by impaction after seeding with Clostridium difficile spores. Design of Experiments (DoE) main effects screening and full factorial design approaches were then employed to investigate the significant factors that heighten the risk of exposure to bioaerosols post-flush. Our findings reveal that the inoculated bacterial concentration (C), time elapsed after flushing (t), lateral distance (d), and mechanical ventilation (v) are significant predictors of bioaerosol concentration, with p-values < 0.05. The interaction term, C × d showed a marked increase in bioaerosol concentration up to 232 CFU/m3 at the closest proximity and highest pathogen load. The interplay of C and t (C × t) demonstrated a time-dependent attenuation of bioaerosol viability, with concentrations peaking at 241 CFU/m3 immediately post-flush and notably diminishing over time. The lateral distance and time post-flush (d × t) interaction also revealed a gradual decrease in bioaerosol concentration, highlighting the effectiveness of spatial and temporal dilution in mitigating bioaerosol exposure risks. Furthermore, there is an immediate rise in relative humidity levels post-flush, impacting the air quality in the toilet environment. This study not only advances our understanding of exposure pathways in determining bioaerosol exposure, but also offers pivotal insights for designing targeted interventions to reduce bioaerosol exposure. Recommendations include designing public toilets with antimicrobial surfaces, optimizing ventilation, and initiating timely disinfection protocols to prioritise surfaces closest to the toilet bowl during peak exposure periods, thereby promoting healthier indoor environments and safeguarding public health in high-traffic toilet settings.
Collapse
Affiliation(s)
- Elizabeth N Paddy
- School of Architecture, Building and Civil Engineering, Loughborough University, Loughborough, Leicestershire, UK.
| | - Oluwasola O D Afolabi
- School of Architecture, Building and Civil Engineering, Loughborough University, Loughborough, Leicestershire, UK
| | - M Sohail
- School of Architecture, Building and Civil Engineering, Loughborough University, Loughborough, Leicestershire, UK
| |
Collapse
|
3
|
Bechmann L, Bauer K, Zerban P, Esser T, Tersteegen A, Fuchs SA, Kaasch AJ, Wolleschak D, Schalk E, Fischer T, Mougiakakos D, Geginat G. Prevention of legionella infections from toilet flushing cisterns. J Hosp Infect 2024; 146:37-43. [PMID: 38224856 DOI: 10.1016/j.jhin.2023.12.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/27/2023] [Accepted: 12/10/2023] [Indexed: 01/17/2024]
Abstract
INTRODUCTION Immunocompromised patients are at an increased risk of severe legionella infections. We present the results of an outbreak investigation initiated following a fatal case of hospital-acquired legionellosis linked to contaminated water from a toilet-flushing cistern. Additionally, we provide experimental data on the growth of Legionella spp. in flushing cisterns and propose a straightforward protocol for prevention. METHODS We monitored the growth of Legionella spp. in the building's hot- and cold-water systems using quantitative bacterial culture on selective agar. Molecular typing of Legionella pneumophila isolates from the infected patient and the water system was conducted through core-genome multi-locus sequence typing (cgMLST). RESULTS Legionella contamination in the hospital building's cold-water system was significantly higher than in the hot-water system and significantly higher in toilet flushing cistern's water compared with cold water from bathroom sinks and showers. Isolates from the patient and from the flushing cistern of the patient's bathroom were identical by cgMLST. In an experimental setting, daily toilet flushing for a period of 21 days resulted in a 67% reduction in the growth of Legionella spp. in the water of toilet flushing cisterns. Moreover, a one-time disinfection of cisterns with peracetic acid, followed by daily flushing, decreased legionella growth to less than 1% over a period of at least seven weeks in these setting. CONCLUSIONS One-time disinfection of highly contaminated cisterns with peracetic acid and daily toilet flushing as short-term measure can significantly reduce legionella contamination in flushing cisterns. These measures may aid in preventing legionella infection among immunocompromised patients.
Collapse
Affiliation(s)
- L Bechmann
- Department of Medical Microbiology and Infection Control, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.
| | - K Bauer
- Department of Medical Microbiology and Infection Control, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - P Zerban
- Department of Medical Microbiology and Infection Control, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - T Esser
- Department of Medical Microbiology and Infection Control, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - A Tersteegen
- Department of Medical Microbiology and Infection Control, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - S A Fuchs
- Institute of Medical Microbiology and Hospital Hygiene, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany
| | - A J Kaasch
- Department of Medical Microbiology and Infection Control, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - D Wolleschak
- Department of Haematology and Oncology, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - E Schalk
- Department of Haematology and Oncology, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - T Fischer
- Department of Haematology and Oncology, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - D Mougiakakos
- Department of Haematology and Oncology, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| | - G Geginat
- Department of Medical Microbiology and Infection Control, Otto-von-Guericke University Magdeburg, Magdeburg, Germany
| |
Collapse
|
4
|
Eisenberg S, Walton A, Connor TH. The Occupational and Environmental Hazards of Uncovered Toilets. Am J Nurs 2024; 124:55-60. [PMID: 38511713 DOI: 10.1097/01.naj.0001010592.45177.43] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/22/2024]
Abstract
ABSTRACT Substantial evidence demonstrates that plumes from uncovered toilets potentially expose nurses and other health care workers to aerosols containing infectious agents and hazardous drugs, including antineoplastic drugs. Most hospitals in the United States utilize flushometer-type toilets, which operate under high pressure and do not have a permanently attached closure or lid, which is known to reduce the aerosols generated by flushing. This article aims to raise awareness among nurses of the potential exposure risks associated with toilet plume aerosols, so they can educate other health care workers and take part in initiatives to address these risks.
Collapse
Affiliation(s)
- Seth Eisenberg
- Seth Eisenberg is an oncology nursing consultant and the former professional practice coordinator of infusion services at the Fred Hutchinson Cancer Center, Seattle. AnnMarie Walton is an associate professor at the Duke University School of Nursing, Durham, NC. Thomas Harry Connor is a retired hazardous drug researcher for the National Institute for Occupational Safety and Health and a former associate professor at the University of Texas Health Science Center at Houston. Contact author: Thomas Harry Connor, . The authors have disclosed no potential conflicts of interest, financial or otherwise
| | | | | |
Collapse
|
5
|
Luo D, Huang J, Zheng X, Liu F, Li Y, Wang Y, Qian H. Spread of flushing-generated fecal aerosols in a squat toilet cubicle: Implication for infection risk. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 859:160212. [PMID: 36395842 DOI: 10.1016/j.scitotenv.2022.160212] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 10/27/2022] [Accepted: 11/12/2022] [Indexed: 06/16/2023]
Abstract
Toilet flushing generates and spread fecal aerosols, potentially leading to infection transmission risk. Squat toilets are widely used in public restrooms in some Asian countries including China and India, and remain to be studied. Aerosol dispersion while flushing squat toilet in cubicle was visualized, while the aerosol concentrations were measured on different surfaces by monitoring fluorescence intensity through seeding simulated fluorescence feces. Flushing-generated fecal aerosols could spread to the breathing zone, deposit on floor, and partitions in squat toilet cubicles, and spread even beyond to the restroom lobby. A total of 0.24 % and 0.17 % of seeded fecal waste deposits on the floor and partition (lower than 0.20 m) for each flush. Aerosol concentration decays rapidly, with 86.8 ± 2.2 % reduction in the second minute after a previous flush compared to that in the first minute. Public toilet users are recommended to wait for 2 min after the early flush before entering the cubicle.
Collapse
Affiliation(s)
- Danting Luo
- School of Energy and Environment, Southeast University, Nanjing, China; Engineering Research Center for Building Energy Environments & Equipments, Ministry of Education, China; Hubei Engineering Center for Infectious Disease Prevention, Control and Treatment, Wuhan, China
| | - Jiayu Huang
- School of Energy and Environment, Southeast University, Nanjing, China; Engineering Research Center for Building Energy Environments & Equipments, Ministry of Education, China
| | - Xiaohong Zheng
- School of Energy and Environment, Southeast University, Nanjing, China; Engineering Research Center for Building Energy Environments & Equipments, Ministry of Education, China
| | - Fan Liu
- School of Energy and Environment, Southeast University, Nanjing, China; University of Shanghai for Science and Technology, Shanghai, China
| | - Yuguo Li
- Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Ying Wang
- Hubei Engineering Center for Infectious Disease Prevention, Control and Treatment, Wuhan, China; Department of infection management, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China
| | - Hua Qian
- School of Energy and Environment, Southeast University, Nanjing, China; Engineering Research Center for Building Energy Environments & Equipments, Ministry of Education, China; Hubei Engineering Center for Infectious Disease Prevention, Control and Treatment, Wuhan, China.
| |
Collapse
|
6
|
Potentially Virulent Multi-Drug Resistant Escherichia fergusonii Isolated from Inanimate Surface in a Medical University: Omphisa fuscidentalis as an Alternative for Bacterial Virulence Determination. Diagnostics (Basel) 2023; 13:diagnostics13020279. [PMID: 36673089 PMCID: PMC9858318 DOI: 10.3390/diagnostics13020279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 12/29/2022] [Accepted: 01/01/2023] [Indexed: 01/14/2023] Open
Abstract
Multi-drug resistant (MDR) bacteria are becoming a worldwide problem due to limited options for treatment. Moreover, patients infected by MDR with highly virulent accessories are worsening the symptoms, even to the point of causing death. In this study, we isolated bacteria from 14 inanimate surfaces that could potentially be reservoirs for the spread of bacterial infections in the medical university. Blood agar media was used for bacterial isolation. The bacterial colony that showed hemolytic activities on each surface was tested for antimicrobial susceptibility against eight different antibiotics. We found that MDR bacterium, namely TB1, which was isolated from a toilet bowl, was non-susceptible to ampicillin, imipenem, chloramphenicol, amoxicillin-clavulanic acid, gentamicin, and tetracycline. Another MDR bacterium isolated from the mobile phone screen of security officers, namely HSO, was resistant to chloramphenicol, gentamicin, tetracycline, and cefixime. An in vivo virulence test of bacterial isolates used Omphisa fuscidentalis larvae as an alternative to Galleria mellonella larvae for the infection model. A virulence test of TB1 in O. fuscidentalis larvae revealed 20% survival in the bacterial density of 104 and 105 CFU/larvae; and 0% survival in the bacterial density of 106 CFU/larvae at 24 h after injection. Bacterial identification was performed for TB1 as a potential virulent isolate. Bacterial identification using partial 16s rRNA gene showed that TB1 exhibited 99.84% identity to Escherichia fergusonii 2611. This study concludes that TB1 is a potentially virulent MDR E. fergusonii isolated from toilet bowls at a medical university.
Collapse
|
7
|
Paraskevopoulos S, Smeets P, Tian X, Medema G. Using Artificial Intelligence to extract information on pathogen characteristics from scientific publications. Int J Hyg Environ Health 2022; 245:114018. [PMID: 35985219 DOI: 10.1016/j.ijheh.2022.114018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 07/29/2022] [Accepted: 07/30/2022] [Indexed: 10/15/2022]
Abstract
Health risk assessment of environmental exposure to pathogens requires complete and up to date knowledge. With the rapid growth of scientific publications and the protocolization of literature reviews, an automated approach based on Artificial Intelligence (AI) techniques could help extract meaningful information from the literature and make literature reviews more efficient. The objective of this research was to determine whether it is feasible to extract both qualitative and quantitative information from scientific publications about the waterborne pathogen Legionella on PubMed, using Deep Learning and Natural Language Processing techniques. The model effectively extracted the qualitative and quantitative characteristics with high precision, recall and F-score of 0.91, 0.80, and 0.85 respectively. The AI extraction yielded results that were comparable to manual information extraction. Overall, AI could reliably extract both qualitative and quantitative information about Legionella from scientific literature. Our study paved the way for a better understanding of the information extraction processes and is a first step towards harnessing AI to collect meaningful information on pathogen characteristics from environmental microbiology publications.
Collapse
Affiliation(s)
- Sotirios Paraskevopoulos
- KWR Water Research Institute, Groningenhaven 7, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands; Department of Water Management, Delft University of Technology, Stevinweg 1, 2628, CN Delft, the Netherlands.
| | - Patrick Smeets
- KWR Water Research Institute, Groningenhaven 7, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands
| | - Xin Tian
- KWR Water Research Institute, Groningenhaven 7, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands
| | - Gertjan Medema
- KWR Water Research Institute, Groningenhaven 7, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands; Department of Water Management, Delft University of Technology, Stevinweg 1, 2628, CN Delft, the Netherlands
| |
Collapse
|
8
|
Proctor C, Garner E, Hamilton KA, Ashbolt NJ, Caverly LJ, Falkinham JO, Haas CN, Prevost M, Prevots DR, Pruden A, Raskin L, Stout J, Haig SJ. Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication. WATER RESEARCH 2022; 211:117997. [PMID: 34999316 PMCID: PMC8821414 DOI: 10.1016/j.watres.2021.117997] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 12/13/2021] [Accepted: 12/19/2021] [Indexed: 05/10/2023]
Abstract
In recent years, drinking water-associated pathogens that can cause infections in immunocompromised or otherwise susceptible individuals (henceforth referred to as DWPI), sometimes referred to as opportunistic pathogens or opportunistic premise plumbing pathogens, have received considerable attention. DWPI research has largely been conducted by experts focusing on specific microorganisms or within silos of expertise. The resulting mitigation approaches optimized for a single microorganism may have unintended consequences and trade-offs for other DWPI or other interests (e.g., energy costs and conservation). For example, the ecological and epidemiological issues characteristic of Legionella pneumophila diverge from those relevant for Mycobacterium avium and other nontuberculous mycobacteria. Recent advances in understanding DWPI as part of a complex microbial ecosystem inhabiting drinking water systems continues to reveal additional challenges: namely, how can all microorganisms of concern be managed simultaneously? In order to protect public health, we must take a more holistic approach in all aspects of the field, including basic research, monitoring methods, risk-based mitigation techniques, and policy. A holistic approach will (i) target multiple microorganisms simultaneously, (ii) involve experts across several disciplines, and (iii) communicate results across disciplines and more broadly, proactively addressing source water-to-customer system management.
Collapse
Affiliation(s)
- Caitlin Proctor
- Department of Agricultural and Biological Engineering, Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, USA
| | - Emily Garner
- Wadsworth Department of Civil & Environmental Engineering, West Virginia University, Morgantown, WV, USA
| | - Kerry A Hamilton
- School of Sustainable Engineering and the Built Environment and The Biodesign Centre for Environmental Health Engineering, Arizona State University, Tempe, AZ, USA
| | - Nicholas J Ashbolt
- Faculty of Science and Engineering, Southern Cross University, Gold Coast. Queensland, Australia
| | - Lindsay J Caverly
- Department of Pediatrics, University of Michigan Medical School, Ann Arbor, MI, USA
| | | | - Charles N Haas
- Department of Civil, Architectural & Environmental Engineering, Drexel University, Philadelphia, PA, USA
| | - Michele Prevost
- Department of Civil, Geological and Mining Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
| | - D Rebecca Prevots
- Epidemiology Unit, Laboratory of Clinical Immunology and Microbiology, Division of Intramural Research, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, MD, USA
| | - Amy Pruden
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, VA USA
| | - Lutgarde Raskin
- Department of Civil & Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Janet Stout
- Department of Civil & Environmental Engineering, University of Pittsburgh, and Special Pathogens Laboratory, Pittsburgh, PA, USA
| | - Sarah-Jane Haig
- Department of Civil & Environmental Engineering, and Department of Environmental & Occupational Health, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
9
|
Abney S, Bright K, McKinney J, Ijaz MK, Gerba C. Toilet hygiene-review and research needs. J Appl Microbiol 2021; 131:2705-2714. [PMID: 33899991 PMCID: PMC9292268 DOI: 10.1111/jam.15121] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 03/26/2021] [Accepted: 04/21/2021] [Indexed: 11/26/2022]
Abstract
The goal of good toilet hygiene is minimizing the potential for pathogen transmission. Control of odours is also socially important and believed to be a societal measure of cleanliness. Understanding the need for good cleaning and disinfecting is even more important today considering the potential spread of emerging pathogens such as SARS-CoV-2 virus. While the flush toilet was a major advancement in achieving these objectives, exposure to pathogens can occur from failure to clean and disinfect areas within a restroom, as well as poor hand hygiene. The build-up of biofilm within a toilet bowl/urinal including sink can result in the persistence of pathogens and odours. During flushing, pathogens can be ejected from the toilet bowl/urinal/sink and be transmitted by inhalation and contaminated fomites. Use of automatic toilet bowl cleaners can reduce the number of microorganisms ejected during a flush. Salmonella bacteria can colonize the underside of the rim of toilets and persist up to 50 days. Pathogenic enteric bacteria appear in greater numbers in the biofilm found in toilets than in the water. Source tracking of bacteria in homes has demonstrated that during cleaning enteric bacteria are transferred from the toilet to the bathroom sinks and that these same bacteria colonize cleaning tools used in the restroom. Quantitative microbial risk assessment has shown that significant risks exist from both aerosols and fomites in restrooms. Cleaning with soaps and detergents without the use of disinfectants in public restrooms may spread bacteria and viruses throughout the restroom. Odours in restrooms are largely controlled by ventilation and flushing volume in toilet/urinals. However, this results in increased energy and water usage. Contamination of both the air and surfaces in restrooms is well documented. Better quantification of the risks of infection are needed as this will help determine what interventions will minimize these risks.
Collapse
Affiliation(s)
- S.E. Abney
- Department of Environmental Science University of Arizona Tucson AZ USA
| | - K.R. Bright
- Department of Environmental Science University of Arizona Tucson AZ USA
| | - J. McKinney
- Global Research and Development for Lysol and Dettol Reckitt Benckiser LLC Montvale NJ USA
| | - M. Khalid Ijaz
- Global Research and Development for Lysol and Dettol Reckitt Benckiser LLC Montvale NJ USA
- Department of Biology Medgar Evers College of the City University of New York (CUNY) Brooklyn NY USA
| | - C.P. Gerba
- Department of Environmental Science University of Arizona Tucson AZ USA
| |
Collapse
|
10
|
Schreck JH, Lashaki MJ, Hashemi J, Dhanak M, Verma S. Aerosol generation in public restrooms. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2021; 33:033320. [PMID: 33897239 PMCID: PMC8060976 DOI: 10.1063/5.0040310] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 02/11/2021] [Indexed: 05/04/2023]
Abstract
Aerosolized droplets play a central role in the transmission of various infectious diseases, including Legionnaire's disease, gastroenteritis-causing norovirus, and most recently COVID-19. Respiratory droplets are known to be the most prominent source of transmission for COVID-19; however, alternative routes may exist given the discovery of small numbers of viable viruses in urine and stool samples. Flushing biomatter can lead to the aerosolization of micro-organisms; thus, there is a likelihood that bioaerosols generated in public restrooms may pose a concern for the transmission of COVID-19, especially since these areas are relatively confined, experience heavy foot traffic, and may suffer from inadequate ventilation. To quantify the extent of aerosolization, we measure the size and number of droplets generated by flushing toilets and urinals in a public restroom. The results indicate that the particular designs tested in the study generate a large number of droplets in the size range 0.3 μ m - 3 μ m , which can reach heights of at least 1.52 m. Covering the toilet reduced aerosol levels but did not eliminate them completely, suggesting that aerosolized droplets escaped through small gaps between the cover and the seat. In addition to consistent increases in aerosol levels immediately after flushing, there was a notable rise in ambient aerosol levels due to the accumulation of droplets from multiple flushes conducted during the tests. This highlights the need for incorporating adequate ventilation in the design and operation of public spaces, which can help prevent aerosol accumulation in high occupancy areas and mitigate the risk of airborne disease transmission.
Collapse
Affiliation(s)
- Jesse H. Schreck
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, Florida 33431, USA
| | - Masoud Jahandar Lashaki
- Department of Civil, Environmental and Geomatics Engineering, Florida Atlantic University, Boca Raton, Florida 33431, USA
| | - Javad Hashemi
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, Florida 33431, USA
| | - Manhar Dhanak
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, Florida 33431, USA
| | - Siddhartha Verma
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, Florida 33431, USA
- Also at: Harbor Branch Oceanographic Institute, Florida Atlantic University, Fort Pierce, FL 34946, USA. Author to whom correspondence should be addressed:. URL:http://www.computation.fau.edu
| |
Collapse
|