1
|
Mehadji B, Ruvalcaba CA, Hernandez AM, Abdelhafez YG, Goldman R, Roncali E. Translating contrast enhanced computed tomography images to liver radioembolization dose distribution for more comprehensively indicating patients. Phys Med Biol 2024; 69:165016. [PMID: 39048102 DOI: 10.1088/1361-6560/ad6748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 07/23/2024] [Indexed: 07/27/2024]
Abstract
Objective.Contrast-enhanced computed tomography (CECT) is commonly used in the pre-treatment evaluation of liver Y-90 radioembolization feasibility. CECT provides detailed imaging of the liver and surrounding structures, allowing healthcare providers to assess the size, location, and characteristics of liver tumors prior to the treatment. Here we propose a method for translating CECT images to an expected dose distribution for tumor(s) and normal liver tissue.Approach.A pre-procedure CECT is used to obtain an iodine arterial-phase distribution by subtracting the non-contrast CT from the late arterial phase. The liver segments surrounding the targeted tumor are selected using Couinaud's method. The resolution of the resulting images is then degraded to match the resolution of the positron emission tomography (PET) images, which can image the Y-90 activity distribution post-treatment. The resulting images are then used in the same way as PET images to compute doses using the local deposition method. CECT images from three patients were used to test this method retrospectively and were compared with Y-90 PET-based dose distributions through dose volume histograms.Main results.Results show a concordance between predicted and delivered Y-90 dose distributions with less than 10% difference in terms of mean dose, for doses greater than 10% of the 98th percentile (D2%).Significance.CECT-derived predictions of Y-90 radioembolization dose distributions seem promising as a supplementary tool for physicians when assessing treatment feasibility. This dosimetry prediction method could provide a more comprehensive pre-treatment evaluation-offering greater insights than a basic assessment of tumor opacification on CT images.
Collapse
Affiliation(s)
- Brahim Mehadji
- Department of Radiology, University of California, Davis, Sacramento, CA, United States of America
| | - Carlos A Ruvalcaba
- Department of Department of Biomedical Engineering, University of California, Davis, Davis, CA, United States of America
| | - Andrew M Hernandez
- Department of Radiology, University of California, Davis, Sacramento, CA, United States of America
| | - Yasser G Abdelhafez
- Department of Radiology, University of California, Davis, Sacramento, CA, United States of America
| | - Roger Goldman
- Department of Radiology, University of California, Davis, Sacramento, CA, United States of America
| | - Emilie Roncali
- Department of Radiology, University of California, Davis, Sacramento, CA, United States of America
- Department of Department of Biomedical Engineering, University of California, Davis, Davis, CA, United States of America
| |
Collapse
|
2
|
Kim TP, Gandhi RT, Tolakanahalli R, Herrera R, Chuong MD, Gutierrez AN, Alvarez D. Establishing Updated Safety Standards for Independent 99mTc-MAA SPECT/CT Treatment Planning in Radioembolization. Int J Radiat Oncol Biol Phys 2024; 119:1285-1296. [PMID: 38925768 DOI: 10.1016/j.ijrobp.2023.12.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 12/08/2023] [Accepted: 12/30/2023] [Indexed: 06/28/2024]
Abstract
PURPOSE Significant improvements within radioembolization imaging and dosimetry permit the development of an accurate and personalized pretreatment plan using technetium 99m-labeled macroaggregated albumin (99mTc-MAA) and single-photon emission computed tomography (SPECT) combined with anatomical CT (SPECT/CT). Despite these potential advantages, the clinical transition to pretreatment protocols with SPECT/CT is hindered by their unknown safety constraints. This study aimed to address this issue by establishing novel dose limits for 99mTc-MAA SPECT/CT to enable quantitative pretreatment planning. METHODS AND MATERIALS Stratification criteria to determine images most viable for dosimetry analysis were created from a cohort of 85 patients. SPECT/CT, cone beam CT, and activity calculations derived from the local deposition method were used to create an accurate pretreatment protocol. Planar and SPECT/CT images were compared using linear regression and modified Bland-Altman analyses to convert accepted planar dose limits to SPECT/CT. To validate these new dose limits, activity calculations based on SPECT/CT were compared with those calculated with the body surface area and planar methods for three treatment plans. RESULTS A total of 38 of 85 patients were deemed viable for dosimetry analysis. SPECT yielded greater lung shunt fractions (LSFs) than planar imaging when LSFs were <4.89%, whereas SPECT yielded lower LSFs than planar imaging when LSFs were >4.89%. Planar to SPECT/CT dose conversions were 0.76×, 0.70×, and 0.55× for the whole liver, normal liver, and lungs, respectively. Patients with SPECT LSFs ≤4.89% were safely treated with the direct application of planar lung dose limits. Activity calculations with the newly established SPECT/CT dose limits were greater than those of the body surface area method by a median range of 33.1% to 61.9% and were lower than planar-based activity calculations by a median range of 12.5% to 13.7% for the whole liver and by 29.4% to 32.2% for the normal liver. CONCLUSIONS This study demonstrated a safe method for translating dose limits from 99mTc-MAA planar imaging to SPECT/CT. A robust pretreatment protocol was further developed guided by the current knowledge in the field. Established SPECT/CT dose limits safely treated 97.5% of patients and permitted the application of independent pretreatment planning with 99mTc-MAA SPECT/CT.
Collapse
Affiliation(s)
| | - Ripal T Gandhi
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida; Interventional Radiology Department, Miami Cardiac and Vascular Institute, Miami, Florida
| | | | - Robert Herrera
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| | - Michael D Chuong
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| | | | - Diane Alvarez
- Radiation Oncology Department, Miami Cancer Institute, Miami, Florida
| |
Collapse
|
3
|
Kim TP, Enger SA. Characterizing the voxel-based approaches in radioembolization dosimetry with reDoseMC. Med Phys 2024; 51:4007-4027. [PMID: 38703394 DOI: 10.1002/mp.17054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 02/15/2024] [Accepted: 02/20/2024] [Indexed: 05/06/2024] Open
Abstract
BACKGROUND Yttrium-90 (90 Y $^{90}{\rm {Y}}$ ) represents the primary radioisotope used in radioembolization procedures, while holmium-166 (166 Ho $^{166}{\rm {Ho}}$ ) is hypothesized to serve as a viable substitute for90 Y $^{90}{\rm {Y}}$ due to its comparable therapeutic potential and improved quantitative imaging. Voxel-based dosimetry for these radioisotopes relies on activity images obtained through PET or SPECT and dosimetry methods, including the voxel S-value (VSV) and the local deposition method (LDM). However, the evaluation of the accuracy of absorbed dose calculations has been limited by the use of non-ideal reference standards and investigations restricted to the liver. The objective of this study was to expand upon these dosimetry characterizations by investigating the impact of image resolutions, voxel sizes, target volumes, and tissue materials on the accuracy of90 Y $^{90}{\rm {Y}}$ and166 Ho $^{166}{\rm {Ho}}$ dosimetry techniques. METHODS A specialized radiopharmaceutical dosimetry software called reDoseMC was developed using the Geant4 Monte Carlo toolkit and validated by benchmarking the generated90 Y $^{90}{\rm {Y}}$ kernels with published data. The decay spectra of both90 Y $^{90}{\rm {Y}}$ and166 Ho $^{166}{\rm {Ho}}$ were also compared. Multiple VSV kernels were generated for the liver, lungs, soft tissue, and bone for isotropic voxel sizes of 1 mm, 2 mm, and 4 mm. Three theoretical phantom setups were created with 20 or 40 mm activity and mass density inserts for the same three voxel sizes. To replicate the limited spatial resolutions present in PET and SPECT images, image resolutions were modeled using a 3D Gaussian kernel with a Full Width at Half Maximum (FWHM) ranging from 0 to 16 mm and with no added noise. The VSV and LDM dosimetry methods were evaluated by characterizing their respective kernels and analyzing their absorbed dose estimates calculated on theoretical phantoms. The ground truth for these estimations was calculated using reDoseMC. RESULTS The decay spectra obtained through reDoseMC showed less than a 1% difference when compared to previously published experimental data for energies below 1.9 MeV in the case of90 Y $^{90}{\rm {Y}}$ and less than 1% for energies below 1.5 MeV for166 Ho $^{166}{\rm {Ho}}$ . Additionally, the validation kernels for90 Y $^{90}{\rm {Y}}$ VSV exhibited results similar to those found in published Monte Carlo codes, with source dose depositions having less than a 3% error margin. Resolution thresholds (FWHM thresh s ${\rm {FWHM}}_\mathrm{thresh}{\rm {s}}$ ), defined as resolutions that resulted in similar dose estimates between the LDM and VSV methods, were observed for90 Y $^{90}{\rm {Y}}$ . They were 1.5 mm for bone, 2.5 mm for soft tissue and liver, and 8.5 mm for lungs. For166 Ho $^{166}{\rm {Ho}}$ , the accuracy of absorbed dose deposition was found to be dependent on the contributions of absorbed dose from photons. Volume errors due to variations in voxel size impacted the final dose estimates. Larger target volumes yielded more accurate mean doses than smaller volumes. For both radioisotopes, the radial dose profiles for the VSV and LDM approximated but never matched the reference standard. CONCLUSIONS reDoseMC was developed and validated for radiopharmaceutical dosimetry. The accuracy of voxel-based dosimetry was found to vary widely with changes in image resolutions, voxel sizes, chosen target volumes, and tissue material; hence, the standardization of dosimetry protocols was found to be of great importance for comparable dosimetry analysis.
Collapse
Affiliation(s)
- Taehyung Peter Kim
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Québec, Canada
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montréal, Québec, Canada
| | - Shirin A Enger
- Medical Physics Unit, Department of Oncology, McGill University, Montreal, Québec, Canada
- Lady Davis Institute for Medical Research, Jewish General Hospital, Montréal, Québec, Canada
| |
Collapse
|
4
|
Kappadath SC, Henry EC, Lopez BP, Mahvash A. Quantitative evaluation of 90Y-PET/CT and 90Y-SPECT/CT-based dosimetry following Yttrium-90 radioembolization. Med Phys 2024. [PMID: 38781554 DOI: 10.1002/mp.17175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 05/02/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024] Open
Abstract
BACKGROUND Following yttrium-90 radioembolization (90Y-RE), 90Y-PET/CT and 90Y-SPECT/CT imaging provide the means to calculate the voxelized absorbed dose distribution. Given the widespread use of the two imaging modalities and lack of well-established standardized dosimetry protocols for 90Y-RE, there is a clinical need to systematically investigate and evaluate differences in the performance of voxel-based dosimetry between 90Y-PET/CT and 90Y-SPECT/CT. PURPOSE To quantitatively analyze and compare 90Y-PET/CT and 90Y-SPECT/CT-based dosimetry following 90Y-RE. METHODS 90Y-PET/CT and 90Y-SPECT/CT imaging was acquired for 35 patients following 90Y-RE with TheraSphere for the treatment of unresectable hepatocellular carcinoma. Dosimetry was performed using the local deposition method with known activity and the mean dose (Dmean) was calculated for perfused liver volumes (PV), tumors (T), and perfused normal livers (NL). Additionally, the absorbed dose to x% of the volume (Dx, x ∈ $ \in $ [5%, 10%, …, 90%, 95%]) and the volume receiving y Gy (Vy, y ∈ $ \in $ [10 Gy, 20 Gy, …, 190 Gy, 200 Gy]) were calculated for T and NL, respectively. Dose metrics were compared using linear regression, Bland-Altman analysis, and statistical testing. RESULTS Both 90Y-SPECT/CT and 90Y-PET/CT-based tumor Dmean were strongly correlated (R2 ≥ 0.90) with Dx, excluding metrics on the extrema. Intra-modality comparisons of various Dx and Vy metrics yielded statistically significant differences (ANOVA, p < 0.001) for both90Y-PET/CT and 90Y-SPECT/CT. Based on statistical testing, only Dx metrics separated by greater than 20%-30% coverage, and only Vy metrics separated by greater than 40-70 Gy, reported significant differences. For PV, there was a strong correlation (R2 ≥ 0.99) between Dmean derived separately from 90Y-PET/CT and 90Y-SPECT/CT imaging. The strength of the correlation was slightly reduced for T and NL with R2 = 0.91 and R2 = 0.95, respectively. For PV, the mean bias ± standard error (SE) and 95% limits of agreement (LOA) between Dmean from the two modalities was effectively zero with -0.8 ± 0.4% (± 2.5%). For T and NL, the mean bias ± SE (± LOA) was -14.5 ± 3.7% (± 24%) and 9.4 ± 4.7% (± 27%), respectively. CONCLUSION The strong correlation between Dmean and Dx suggests information from multiple dose metrics (e.g., D70 and Dmean) is largely redundant when establishing dose-response relationships in 90Y-RE. Dmean is highly correlated between 90Y-PET/CT and 90Y-SPECT/CT-based dosimetry, for all liver VOIs. Relative to 90Y-SPECT/CT, 90Y-PET/CT, on average, yielded higher Dmean to tumors (14%) and lower Dmean to perfused normal livers (9%). Absorbed dose differences for perfused liver volumes between 90Y-SPECT/CT and 90Y-PET/CT were negligible.
Collapse
Affiliation(s)
| | - Eric Courtney Henry
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Benjamin P Lopez
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Armeen Mahvash
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
5
|
Henry EC, Mahvash A, Lopez BP, Kappadath SC. A comparison of methods for in vivo activity and absorbed dose quantification with PET/CT following yttrium-90 radioembolization. Med Phys 2024. [PMID: 38772046 DOI: 10.1002/mp.17174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 05/02/2024] [Accepted: 05/07/2024] [Indexed: 05/23/2024] Open
Abstract
BACKGROUND Yttrium-90 (90Y) positron emission tomography (PET)/computed tomography (CT) imaging is increasingly being used to perform tumor (T) and normal liver (NL) voxel dosimetry after 90Y-radioembolization (90Y-RE). Yet, the accuracy of in vivo 90Y-PET/CT imaging, subject to motion blur and co-registration inaccuracies, and 90Y-PET/CT dose quantification, subject to availability of different voxel dosimetry algorithms, are not well understood. PURPOSE The purpose of this study was to investigate the accuracy of 90Y-PET/CT-based activity estimates following 90Y-RE and characterize differences between 90Y-PET/CT-based voxel dosimetry algorithms. METHODS Thirty-five patients underwent 90Y-PET/CT imaging after 90Y-RE with TheraSphere. The net administered 90Y activity (Aadmin) was determined using a dose calibrator and pre- and post-procedure exposure rate measurements. The summation of image-based activity (Aimage) was extracted from perfused volume (PV) and 3D-isotropically 2-cm expanded PV contour (PV+2 cm). Absorbed doses were calculated using voxel S-value (VSV), local deposition method (LDM), and LDM with known activity (LDMKA) dosimetry algorithms. Linear regression and Bland-Altman analysis quantified the relationship between Aimage and Aadmin and between mean dose estimates (DLDM, DVSV, DLDM-KA) for PV, T, and perfused NL volumes. RESULTS While Aadmin and Aimage in PV were highly correlated (R2 > 0.95), the mean bias ± standard error (SE) and (95% limits of agreement, LOA) was significantly non-zero with -22.7 ± 4.7% (± 28.4%). In PV+2 cm, the mean bias ± SE (± LOA) decreased to 1.3 ± 3.4% (± 18.0%) consistent with zero mean error. DLDM and DVSV were highly correlated (R2 > 0.99) for all volumes of interest (VOIs) and the mean bias ± SE (± LOA) was 2.2 ± 0.2% (± 1.0%), 0.7 ± 0.4% (± 2.8%), and 3.2 ± 0.5% (± 2.8%) for PV, T, and NL, respectively. DLDM-KA and DVSV were correlated with R2 = 0.86, 0.80, and 0.86 for PV, T, and NL, respectively. The mean bias ± SE (± LOA) between DLDM-KA and DVSV was significantly non-zero with -19.6 ± 5.1% (± 31.0%), -20.8 ± 4.4% (± 29.0%), and -18.1 ± 5.3% (± 31.1%) for PV, T, and NL, respectively. CONCLUSIONS The summation of Aimage in PV was underestimated relative to Aadmin. Only by accounting for respiratory motion, limited spatial resolution, and PET/CT co-registration errors through VOI expansion was Aimage, on average, equal to Aadmin. The differences between DLDM and DVSV were not clinically relevant, though DLDM-KA was approximately 20% greater than DVSV. Given the high quantitative accuracy of dose calibrators and challenges associated with accurate 90Y-PET/CT quantification, LDMKA is the preferred algorithm for accurate 90Y-PET/CT-based dosimetry following 90Y-RE.
Collapse
Affiliation(s)
- Eric Courtney Henry
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Armeen Mahvash
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Benjamin P Lopez
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | | |
Collapse
|
6
|
Bastiaannet R, Lin M, Frey EC, de Jong HW. Intraprocedural C-arm dual-phase cone-beam enhancement patterns correlate with tumor absorbed dose after radioembolization. Med Phys 2024; 51:3045-3052. [PMID: 38064591 PMCID: PMC10994751 DOI: 10.1002/mp.16882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 11/17/2023] [Accepted: 11/17/2023] [Indexed: 04/05/2024] Open
Abstract
BACKGROUND Recent studies have shown a clear relationship between absorbed dose and tumor response to treatment after hepatic radioembolization. These findings help to create more personalized treatment planning and dosimetry. However, crucial to this goal is the ability to predict the dose distribution prior to treatment. The microsphere distribution is ultimately determined by (i) the hepatic vasculature and the resulting blood flow dynamics and (ii) the catheter position. PURPOSE To show that pretreatment, intra-procedural imaging of blood flow patterns, as quantified by catheter-directed intra-arterial contrast enhancement, correlate with posttreatment microsphere accumulation and, consequently, absorbed dose. MATERIALS AND METHODS Patients who participated in a clinical trial (NCT01177007) and for whom both a pretreatment dual-phase contrast-enhanced cone-beam CT (CBCT) and a posttreatment 90Y PET/CT scan were available were included in this retrospective study. Tumors and perfused volumes were manually delineated on the CBCT by an experienced radiologist. The mean, sum, and standard deviation of the voxels in each volume were recorded. The delineations were transferred to the PET-based absorbed dose maps by coregistration of the corresponding CTs. Linear multiple regression was used to correlate pretreatment CBCT enhancement to posttreatment 90Y PET/CT-based absorbed dose in each region. Leave-one-out cross-validation and Bland-Altman analyses were performed on the predicted versus measured absorbed doses. RESULTS Nine patients, with a total of 23 tumors were included. All presented with hepatocellular carcinoma (HCC). Visually, all patients had a clear correspondence between CBCT enhancement and absorbed dose. The correlation between CBCT enhancement and posttherapy absorbed tumor dose based was strong (R2 = 0.91), and moderate for the non-tumor liver tissue (R2 = 0.61). Limits of agreement were approximately ±55 Gray for tumor tissue. CONCLUSION There is a linear relationship between pretreatment blood dynamics in HCC tumors and posttreatment absorbed dose, which, if shown to be generalizable, allows for pretreatment tumor absorbed dose prediction.
Collapse
Affiliation(s)
- Remco Bastiaannet
- The Russell H Morgan Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, MD, United States
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - MingDe Lin
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, CT, United States
| | - Eric C. Frey
- The Russell H Morgan Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, MD, United States
| | - Hugo W.A.M. de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
7
|
Busse NC, Al‐Ghazi MSAL, Abi‐Jaoudeh N, Alvarez D, Ayan AS, Chen E, Chuong MD, Dezarn WA, Enger SA, Graves SA, Hobbs RF, Jafari ME, Kim SP, Maughan NM, Polemi AM, Stickel JR. AAPM Medical Physics Practice Guideline 14.a: Yttrium-90 microsphere radioembolization. J Appl Clin Med Phys 2024; 25:e14157. [PMID: 37820316 PMCID: PMC10860558 DOI: 10.1002/acm2.14157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 06/19/2023] [Accepted: 08/25/2023] [Indexed: 10/13/2023] Open
Abstract
Radioembolization using Yttrium-90 (90 Y) microspheres is widely used to treat primary and metastatic liver tumors. The present work provides minimum practice guidelines for establishing and supporting such a program. Medical physicists play a key role in patient and staff safety during these procedures. Products currently available are identified and their properties and suppliers summarized. Appropriateness for use is the domain of the treating physician. Patient work up starts with pre-treatment imaging. First, a mapping study using Technetium-99m (Tc-99m ) is carried out to quantify the lung shunt fraction (LSF) and to characterize the vascular supply of the liver. An MRI, CT, or a PET-CT scan is used to obtain information on the tumor burden. The tumor volume, LSF, tumor histology, and other pertinent patient characteristics are used to decide the type and quantity of 90 Y to be ordered. On the day of treatment, the appropriate dose is assayed using a dose calibrator with a calibration traceable to a national standard. In the treatment suite, the care team led by an interventional radiologist delivers the dose using real-time image guidance. The treatment suite is posted as a radioactive area during the procedure and staff wear radiation dosimeters. The treatment room, patient, and staff are surveyed post-procedure. The dose delivered to the patient is determined from the ratio of pre-treatment and residual waste exposure rate measurements. Establishing such a treatment modality is a major undertaking requiring an institutional radioactive materials license amendment complying with appropriate federal and state radiation regulations and appropriate staff training commensurate with their respective role and function in the planning and delivery of the procedure. Training, documentation, and areas for potential failure modes are identified and guidance is provided to ameliorate them.
Collapse
Affiliation(s)
| | | | - Nadine Abi‐Jaoudeh
- Department of Radiological SciencesUniversity of CaliforniaIrvineCaliforniaUSA
| | - Diane Alvarez
- Baptist HospitalMiami Cancer InstituteMiamiFloridaUSA
| | - Ahmet S. Ayan
- Department of Radiation OncologyOhio State UniversityColumbusOhioUSA
| | - Erli Chen
- Department of Radiation OncologyCheshire Medical CenterKeeneNew HampshireUSA
| | - Michael D. Chuong
- Department of Radiation OncologyMiami Cancer InstituteMiamiFloridaUSA
| | - William A. Dezarn
- Department of Radiation OncologyWake Forest University School of MedicineWinston‐SalemNorth CarolinaUSA
| | | | | | - Robert F. Hobbs
- Department of Radiation OncologyJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Mary Ellen Jafari
- Diagnostic Physics, Atlantic Health SystemMorristown Medical CenterMorristownNew JerseyUSA
| | - S. Peter Kim
- Medical Physics UnitMcGill UniversityMontrealCanada
| | - Nichole M. Maughan
- Department of Radiation OncologyWashington University in St. LouisSaint LouisMissouriUSA
| | - Andrew M. Polemi
- Department of RadiologyUniversity of VirginiaCharlottesvilleVirginiaUSA
| | | |
Collapse
|
8
|
Della Gala G, Santoro M, Rasoatsaratanany GA, Paolani G, Strolin S, Strigari L. A single centre intercomparison between commercial treatment planning systems for 90Y radioembolization using virtual and experimental phantoms. Phys Med 2023; 116:103172. [PMID: 38001000 DOI: 10.1016/j.ejmp.2023.103172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 10/30/2023] [Accepted: 11/14/2023] [Indexed: 11/26/2023] Open
Abstract
INTRODUCTION Dedicated Treatment Planning Systems (TPSs) were developed to personalize 90Y-transarterial radioembolization. This study evaluated the agreement among four commercial TPSs assessing volumes of interest (VOIs) volumes and dose metrics. METHODS A homogeneous (EH) and an anthropomorphic phantom with hot and cold inserts (EA) filled with 99mTc-pertechnetate were acquired with a SPECT/CT scanner. Their virtual versions (VH and VA, respectively) and a phantom with activity inside a single voxel (VK) were generated by an in-house MATLAB script. Images and delineated VOIs were imported into the TPSs to compute voxel-based absorbed dose distributions with various dose deposition approaches: local deposition method (LDM) and dose kernel convolution (DKC) with/without local density correction (LDC). VOI volumes and mean absorbed doses were assessed against their median value across TPSs. Dose-volume histograms (DVHs) and VK-derived dose profiles were evaluated. RESULTS Small (<2.1 %) and large (up to 42.4 %) relative volume differences were observed on large (>500 ml) and small VOIs, respectively. Mean absorbed doses relative differences were < 3 % except for small VOIs with steep dose gradients (up to 89.1 % in the VA Cold Sphere VOI). Within the same TPS, LDC negligibly affected the mean absorbed dose, while DKC and LDM showed differences up to 63 %. DHVs were mostly overlapped in experimental phantoms, with some differences in the virtual versions. Dose profiles agreed within 1 %. CONCLUSION TPSs showed an overall good agreement except for small VOI volumes and mean absorbed doses of VOIs with steep dose gradients. These discrepancies should be considered in the dosimetry uncertainty assessment, thus requiring an appropriate harmonization.
Collapse
Affiliation(s)
- Giuseppe Della Gala
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Miriam Santoro
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Garoson Albertine Rasoatsaratanany
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy; International Center for Theoretical Physics (ICTP), Strada Costiera, 11, 34151, Trieste, Italy
| | - Giulia Paolani
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Silvia Strolin
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Lidia Strigari
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy.
| |
Collapse
|
9
|
Pham TP, Presles B, Popoff R, Alberini JL, Vrigneaud JM. Pre-treatment dosimetry in 90Y-SIRT: Is it possible to optimise SPECT reconstruction parameters and calculation methods for accurate dosimetry? Phys Med 2023; 115:103145. [PMID: 37852020 DOI: 10.1016/j.ejmp.2023.103145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 06/03/2023] [Accepted: 09/21/2023] [Indexed: 10/20/2023] Open
Abstract
PURPOSE The aim of this study was (a) to optimise the99mTc-SPECT reconstruction parameters for the pre-treatment dosimetry of90Y-selective internal radiation therapy (SIRT) and (b) to compare the accuracy of clinical dosimetry methods with full Monte-Carlo dosimetry (fMCD) performed with Gate. METHODS To optimise the reconstruction parameters, two hundred reconstructions with different parameters were performed on a NEMA phantom, varying the number of iterations, subsets, and post-filtering. The accuracy of the dosimetric methods was then investigated using an anthropomorphic phantom. Absorbed dose maps were generated using (1) the Partition Model (PM), (2) the Dose Voxel Kernel (DVK) convolution, and (3) the Local Deposition Method (LDM) with known activity restricted to the whole phantom (WP) or to the liver and lungs (LL). The dose to the lungs was calculated using the "multiple DVK" and "multiple LDM" methods. RESULTS Optimal OSEM reconstruction parameters were found to depend on object size and dosimetric criterion chosen (Dmean or DVH-derived metric). The Dmean of all three dosimetric methods was close (≤ 10%) to the Dmean of fMCD simulations when considering large segmented volumes (whole liver, normal liver). In contrast, the Dmean to the small volume (∅=31) was systemically underestimated (12%-25%). For lungs, the "multiple DVK" and "multiple LDM" methods yielded a Dmean within 20% for the WP method and within 10% for the LL method. CONCLUSIONS All three methods showed a substantial degradation of the dose-volume histograms (DVHs) compared to fMCD simulations. The DVK and LDM methods performed almost equally well, with the "multiple DVK" method being more accurate in the lungs.
Collapse
Affiliation(s)
- Tien-Phong Pham
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France.
| | - Benoit Presles
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France
| | - Romain Popoff
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France
| | - Jean-Louis Alberini
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France
| | - Jean-Marc Vrigneaud
- Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) - UMR CNRS 6302, University of Burgundy, Dijon, France; Department of Nuclear Medicine, Georges-François Leclerc Cancer Centre, Dijon, France.
| |
Collapse
|
10
|
Tabotta F, Gnesin S, Dunet V, Ponti A, Digklia A, Boughdad S, Schaefer N, Prior JO, Villard N, Tsoumakidou G, Denys A, Duran R. 99mTc-macroaggregated albumin SPECT/CT predictive dosimetry and dose-response relationship in uveal melanoma liver metastases treated with first-line selective internal radiation therapy. Sci Rep 2023; 13:13118. [PMID: 37573346 PMCID: PMC10423257 DOI: 10.1038/s41598-023-39994-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 08/03/2023] [Indexed: 08/14/2023] Open
Abstract
First-line selective internal radiation therapy (SIRT) showed promising outcomes in patients with uveal melanoma liver metastases (UMLM). Patient survival depends on liver's disease control. SIRT planning is essential and little is known about dosimetry. We investigated whether 99mTc-MAA-SPECT/CT dosimetry could predict absorbed doses (AD) evaluated on 90Y-PET/CT and assess the dose-response relationship in UMLM patients treated with first-line SIRT. This IRB-approved, single-center, retrospective analysis (prospectively collected cohort) included 12 patients (median age 63y, range 43-82). Patients underwent MRI/CT, 18F-FDG-PET/CT before and 3-6 months post-SIRT, and 90Y-PET/CT immediately post-SIRT. Thirty-two target lesions were included. AD estimates in tumor and non-tumor liver were obtained from 99mTc-MAA-SPECT/CT and post-SIRT 90Y-PET/CT, and assessed with Lin's concordance correlation coefficients (ρc and Cb), Pearson's coefficient correlation (ρ), and Bland-Altman analyses (mean difference ± standard deviation; 95% limits-of-agreement (LOA)). Influence of tumor characteristics and microsphere type on AD was analyzed. Tumor response was assessed according to size-based, enhancement-based and metabolic response criteria. Mean target lesion AD was 349 Gy (range 46-1586 Gy). Concordance between 99mTc-MAA-SPECT/CT and 90Y-PET/CT tumor dosimetry improved upon dose correction for the recovery coefficient (RC) (ρ = 0.725, ρc = 0.703, Cb = 0.969) with good agreement (mean difference: - 4.93 ± 218.3 Gy, 95%LOA: - 432.8-422.9). Without RC correction, concordance was better for resin microspheres (ρ = 0.85, ρc = 0.998, Cb = 0.849) and agreement was very good between predictive 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (mean difference: - 4.05 ± 55.9 Gy; 95%LOA: - 113.7-105.6). After RC correction, 99mTc-MAA-SPECT/CT dosimetry overestimated AD (- 70.9 ± 158.9 Gy; 95%LOA: - 382.3-240.6). For glass microspheres, concordance markedly improved with RC correction (ρ = 0.790, ρc = 0.713, Cb = 0.903 vs without correction: ρ = 0.395, ρc = 0.244, Cb = 0.617) and 99mTc-MAA-SPECT/CT dosimetry underestimated AD (148.9 ± 267.5 Gy; 95%LOA: - 375.4-673.2). For non-tumor liver, concordance was good between 99mTc-MAA-SPECT/CT and 90Y-PET/CT dosimetry (ρ = 0.942, ρc = 0.852, Cb = 0.904). 99mTc-MAA-SPECT/CT slightly overestimated liver AD for resin (3.4 ± 3.4 Gy) and glass (11.5 ± 13.9 Gy) microspheres. Tumor AD was not correlated with baseline or post-SIRT lesion characteristics and no dose-response threshold could be identified. 99mTc-MAA-SPECT/CT dosimetry provides good estimates of AD to tumor and non-tumor liver in UMLM patients treated with first-line SIRT.
Collapse
Affiliation(s)
- Flavian Tabotta
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Silvano Gnesin
- Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Vincent Dunet
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Alexandre Ponti
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Antonia Digklia
- Department of Medical Oncology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Sarah Boughdad
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Niklaus Schaefer
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - John O Prior
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Nicolas Villard
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Georgia Tsoumakidou
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Alban Denys
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Rafael Duran
- Department of Radiology and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| |
Collapse
|
11
|
Stella M, van Rooij R, Lam MGEH, de Jong HWAM, Braat AJAT. Lung Dose Measured on Postradioembolization 90Y PET/CT and Incidence of Radiation Pneumonitis. J Nucl Med 2022; 63:1075-1080. [PMID: 34772794 PMCID: PMC9258566 DOI: 10.2967/jnumed.121.263143] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 10/26/2021] [Indexed: 01/03/2023] Open
Abstract
Radiation pneumonitis is a rare but possibly fatal side effect of 90Y radioembolization. It may occur 1-6 mo after therapy, if a significant part of the 90Y microspheres shunts to the lungs. In current clinical practice, a predicted lung dose greater than 30 Gy is considered a criterion to exclude patients from treatment. However, contrasting findings regarding the occurrence of radiation pneumonitis and lung dose were previously reported in the literature. In this study, the relationship between the lung dose and the eventual occurrence of radiation pneumonitis after 90Y radioembolization was investigated. Methods: We retrospectively analyzed 317 90Y liver radioembolization procedures performed during an 8-y period (February 2012 to September 2020). We calculated the predicted lung mean dose (LMD) using 99mTc-MAA planar scintigraphy (LMDMAA) acquired during the planning phase and left LMD (LMDY-90) using the 90Y PET/CT acquired after the treatment. For the lung dose computation, we used the left lung as the representative lung volume, to compensate for scatter from the liver moving in the craniocaudal direction because of breathing and mainly affecting the right lung. Results: In total, 272 patients underwent 90Y procedures, of which 63% were performed with glass microspheres and 37% with resin microspheres. The median injected activity was 1,974 MBq (range, 242-9,538 MBq). The median LMDMAA was 3.5 Gy (range, 0.2-89.0 Gy). For 14 procedures, LMDMAA was more than 30 Gy. Median LMDY-90 was 1 Gy (range, 0.0-22.1 Gy). No patients had an LMDY-90 of more than 30 Gy. Of the 3 patients with an LMDY-90 of more than 12 Gy, 2 patients (one with an LMDY-90 of 22.1 Gy and an LMDMAA of 89 Gy; the other with an LMDY-90 of 17.7 Gy and an LMDMAA of 34.1 Gy) developed radiation pneumonitis and consequently died. The third patient, with an LMDY-90 of 18.4 Gy (LMDMAA, 29.1 Gy), died 2 mo after treatment, before the imaging evaluation, because of progressive disease. Conclusion: The occurrence of radiation pneumonitis as a consequence of a lung shunt after 90Y radioembolization is rare (<1%). No radiation pneumonitis developed in patients with a measured LMDY-90 lower than 12 Gy.
Collapse
Affiliation(s)
- Martina Stella
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Rob van Rooij
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Marnix G E H Lam
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Hugo W A M de Jong
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Arthur J A T Braat
- Division of Imaging and Oncology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
12
|
Ramonaheng K, van Staden JA, du Raan H. Accuracy of two dosimetry software programs for 177Lu radiopharmaceutical therapy using voxel-based patient-specific phantoms. Heliyon 2022; 8:e09830. [PMID: 35865988 PMCID: PMC9293745 DOI: 10.1016/j.heliyon.2022.e09830] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 02/18/2022] [Accepted: 06/24/2022] [Indexed: 12/01/2022] Open
Abstract
Purpose Virtual dosimetry using voxel-based patient-specific phantoms and Monte Carlo (MC) simulations offer the advantage of having a gold standard against which absorbed doses may be benchmarked to establish the dosimetry accuracy. Furthermore, these reference values assist in investigating the accuracy of the absorbed dose methodologies from different software programs. Therefore, this study aimed to compare the accuracy of the absorbed doses computed using LundADose and OLINDA/EXM 1.0. Methods The accuracy was based on 177Lu-DOTATATE distributions of three voxel-based phantoms. SPECT projection images were simulated for 1, 24, 96, and 168 h post-administration and reconstructed with LundADose using 3D OS-EM reconstruction. Mono-exponential curves were fitted to the bio-kinetic data for the kidneys, liver, spleen, and tumours resulting in SPECT time-integrated activity (SPECT-TIA). The SPECT-TIA were used to compute mean absorbed doses using LundADose (LND-DSPECT) and OLINDA (OLINDA-DSPECT) for the organs. Pre-defined true activity images, were used to obtain TRUE-TIA and, together with full MC simulations, computed the true doses (MC-DTrue). The dosimetry accuracy was assessed by comparing LND-DSPECT and OLINDA-DSPECT to MC-DTrue. Results Overall, the results presented an overestimation of the mean absorbed dose by LND-DSPECT compared to the MC-DTrue with a dosimetry accuracy ≤6.6%. This was attributed to spill-out activity from the reconstructed LND-DSPECT, resulting in a higher dose contribution than the MC-DTrue. There was a general underestimation (<8.1%) of OLINDA-DSPECT compared to MC-DTrue attributed to the geometrical difference in shape between the voxel-based phantoms and the OLINDA models. Furthermore, OLINDA-DSPECT considers self-doses while MC-DTrue reflects self-doses plus cross-doses. Conclusion The better than 10% accuracy suggests that the mean dose values obtained with LND-DSPECT and OLINDA-DSPECT approximate the true values. The mean absorbed doses of the two software programs, and the gold standard were comparable. This work shall be of use for optimising 177Lu dosimetry for clinical applications.
Collapse
Affiliation(s)
- Keamogetswe Ramonaheng
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, P.O. Box 339, Bloemfontein, 9300, South Africa
| | - Johannes A van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, P.O. Box 339, Bloemfontein, 9300, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, P.O. Box 339, Bloemfontein, 9300, South Africa
| |
Collapse
|
13
|
Henry EC, Strugari M, Mawko G, Brewer K, Liu D, Gordon AC, Bryan JN, Maitz C, Karnia JJ, Abraham R, Kappadath SC, Syme A. Precision dosimetry in yttrium-90 radioembolization through CT imaging of radiopaque microspheres in a rabbit liver model. EJNMMI Phys 2022; 9:21. [PMID: 35312882 PMCID: PMC8938593 DOI: 10.1186/s40658-022-00447-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 03/02/2022] [Indexed: 12/24/2022] Open
Abstract
PURPOSE To perform precision dosimetry in yttrium-90 radioembolization through CT imaging of radiopaque microspheres in a rabbit liver model and to compare extracted dose metrics to those produced from conventional PET-based dosimetry. MATERIALS AND METHODS A CT calibration phantom was designed containing posts with nominal microsphere concentrations of 0.5 mg/mL, 5.0 mg/mL, and 25.0 mg/mL. The mean Hounsfield unit was extracted from the post volumes to generate a calibration curve to relate Hounsfield units to microsphere concentration. A nominal bolus of 40 mg of microspheres was administered to the livers of eight rabbits, followed by PET/CT imaging. A CT-based activity distribution was calculated through the application of the calibration curve to the CT liver volume. Post-treatment dosimetry was performed through the convolution of yttrium-90 dose-voxel kernels and the PET- and CT-based cumulated activity distributions. The mean dose to the liver in PET- and CT-based dose distributions was compared through linear regression, ANOVA, and Bland-Altman analysis. RESULTS A linear least-squares fit to the average Hounsfield unit and microsphere concentration data from the calibration phantom confirmed a strong correlation (r2 > 0.999) with a slope of 14.13 HU/mg/mL. A poor correlation was found between the mean dose derived from CT and PET (r2 = 0.374), while the ANOVA analysis revealed statistically significant differences (p < 10-12) between the MIRD-derived mean dose and the PET- and CT-derived mean dose. Bland-Altman analysis predicted an offset of 15.0 Gy between the mean dose in CT and PET. The dose within the liver was shown to be more heterogeneous in CT than in PET with an average coefficient of variation equal to 1.99 and 1.02, respectively. CONCLUSION The benefits of a CT-based approach to post-treatment dosimetry in yttrium-90 radioembolization include improved visualization of the dose distribution, reduced partial volume effects, a better representation of dose heterogeneity, and the mitigation of respiratory motion effects. Post-treatment CT imaging of radiopaque microspheres in yttrium-90 radioembolization provides the means to perform precision dosimetry and extract accurate dose metrics used to refine the understanding of the dose-response relationship, which could ultimately improve future patient outcomes.
Collapse
Affiliation(s)
- E Courtney Henry
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, Canada.
| | - Matthew Strugari
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, Canada
- Biomedical Translational Imaging Centre, Halifax, NS, Canada
| | - George Mawko
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, Canada
- Department of Medical Physics, Nova Scotia Health Authority, Halifax, NS, Canada
- Department of Radiation Oncology, Dalhousie University, Halifax, NS, Canada
- Department of Diagnostic Radiology, Dalhousie University, Halifax, NS, Canada
| | - Kimberly Brewer
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, Canada
- Biomedical Translational Imaging Centre, Halifax, NS, Canada
- Department of Diagnostic Radiology, Dalhousie University, Halifax, NS, Canada
- Department of Biomedical Engineering, Dalhousie University, Halifax, NS, Canada
| | - David Liu
- School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
| | - Andrew C Gordon
- Department of Radiology, Northwestern University, Chicago, IL, USA
| | - Jeffrey N Bryan
- Department of Veterinary Medicine and Surgery, University of Missouri, Columbia, MO, USA
| | - Charles Maitz
- Department of Veterinary Medicine and Surgery, University of Missouri, Columbia, MO, USA
| | - James J Karnia
- Department of Veterinary Medicine and Surgery, University of Missouri, Columbia, MO, USA
| | - Robert Abraham
- Department of Diagnostic Radiology, Dalhousie University, Halifax, NS, Canada
- ABK Biomedical Inc., Halifax, NS, Canada
| | - S Cheenu Kappadath
- Department of Imaging Physics, University of Texas MD Anderson Cancer Centre, Houston, TX, USA
| | - Alasdair Syme
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, Canada
- Department of Medical Physics, Nova Scotia Health Authority, Halifax, NS, Canada
- Department of Radiation Oncology, Dalhousie University, Halifax, NS, Canada
| |
Collapse
|
14
|
Danieli R, Milano A, Gallo S, Veronese I, Lascialfari A, Indovina L, Botta F, Ferrari M, Cicchetti A, Raspanti D, Cremonesi M. Personalized Dosimetry in Targeted Radiation Therapy: A Look to Methods, Tools and Critical Aspects. J Pers Med 2022; 12:205. [PMID: 35207693 PMCID: PMC8874397 DOI: 10.3390/jpm12020205] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/13/2022] [Accepted: 01/14/2022] [Indexed: 12/10/2022] Open
Abstract
Targeted radiation therapy (TRT) is a strategy increasingly adopted for the treatment of different types of cancer. The urge for optimization, as stated by the European Council Directive (2013/59/EURATOM), requires the implementation of a personalized dosimetric approach, similar to what already happens in external beam radiation therapy (EBRT). The purpose of this paper is to provide a thorough introduction to the field of personalized dosimetry in TRT, explaining its rationale in the context of optimization and describing the currently available methodologies. After listing the main therapies currently employed, the clinical workflow for the absorbed dose calculation is described, based on works of the most experienced authors in the literature and recent guidelines. Moreover, the widespread software packages for internal dosimetry are presented and critical aspects discussed. Overall, a selection of the most important and recent articles about this topic is provided.
Collapse
Affiliation(s)
- Rachele Danieli
- Dipartimento di Fisica, Università degli Studi di Pavia, Via Bassi 6, 27100 Pavia, Italy;
| | - Alessia Milano
- Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo F. Vito 1, 00168 Roma, Italy;
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Università Cattolica del Sacro Cuore, Largo F. Vito 1, 00168 Roma, Italy
| | - Salvatore Gallo
- Dipartimento di Fisica “Aldo Pontremoli”, Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (S.G.); (I.V.)
- INFN Sezione di Milano, Via Celoria 16, 20133 Milano, Italy
| | - Ivan Veronese
- Dipartimento di Fisica “Aldo Pontremoli”, Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (S.G.); (I.V.)
- INFN Sezione di Milano, Via Celoria 16, 20133 Milano, Italy
| | - Alessandro Lascialfari
- INFN-Pavia Unit, Department of Physics, University of Pavia, Via Bassi 6, 27100 Pavia, Italy;
| | - Luca Indovina
- Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo F. Vito 1, 00168 Roma, Italy;
| | - Francesca Botta
- Medical Physics Unit, European Institute of Oncology IRCCS, Via Giuseppe Ripamonti 435, 20141 Milano, Italy; (F.B.); (M.F.)
| | - Mahila Ferrari
- Medical Physics Unit, European Institute of Oncology IRCCS, Via Giuseppe Ripamonti 435, 20141 Milano, Italy; (F.B.); (M.F.)
| | - Alessandro Cicchetti
- Prostate Cancer Program, Fondazione IRCCS Istituto Nazionale dei Tumori, Via Giacomo Venezian, 1, 20133 Milano, Italy;
| | - Davide Raspanti
- Temasinergie S.p.A., Via Marcello Malpighi 120, 48018 Faenza, Italy;
| | - Marta Cremonesi
- Radiation Research Unit, European Institute of Oncology IRCCS, Via Giuseppe Ripamonti 435, 20141 Milano, Italy;
| |
Collapse
|
15
|
Kennedy J, Chicheportiche A, Keidar Z. Quantitative SPECT/CT for dosimetry of peptide receptor radionuclide therapy. Semin Nucl Med 2021; 52:229-242. [PMID: 34911637 DOI: 10.1053/j.semnuclmed.2021.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Neuroendocrine tumors (NETs) are uncommon malignancies of increasing incidence and prevalence. As these slow growing tumors usually overexpress somatostatin receptors (SSTRs), the use of 68Ga-DOTA-peptides (gallium-68 chelated with dodecane tetra-acetic acid to somatostatin), which bind to the SSTRs, allows for PET based imaging and selection of patients for peptide receptor radionuclide therapy (PRRT). PRRT with radiolabeled somatostatin analogues such as 177Lu-DOTATATE (lutetium-177-[DOTA,Tyr3]-octreotate), is mainly used for the treatment of metastatic or inoperable NETs. However, PRRT is generally administered at a fixed injected activity in order not to exceed dose limits in critical organs, which is suboptimal given the variability in radiopharmaceutical uptake among patients. Advances in SPECT (single photon emission computed tomography) imaging enable the absolute quantitative measure of the true radiopharmaceutical distribution providing for PRRT dosimetry in each patient. Personalized PRRT based on patient-specific dosimetry could improve therapeutic efficacy by optimizing effective tumor absorbed dose while limiting treatment related radiotoxicity.
Collapse
Affiliation(s)
- John Kennedy
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel; B. Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
| | - Alexandre Chicheportiche
- Department of Nuclear Medicine and Biophysics, Hadassah Medical Organization and Faculty of Medicine, Hebrew University of Jerusalem, Israel
| | - Zohar Keidar
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel; B. Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
16
|
Della Gala G, Bardiès M, Tipping J, Strigari L. Overview of commercial treatment planning systems for targeted radionuclide therapy. Phys Med 2021; 92:52-61. [PMID: 34864422 DOI: 10.1016/j.ejmp.2021.11.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 10/23/2021] [Accepted: 11/12/2021] [Indexed: 10/19/2022] Open
Abstract
INTRODUCTION Targeted Radionuclide Therapy (TRT) is a branch of cancer medicine dealing with the therapeutic use of radioisotopes associated with biological vectors accumulating in the tumors/targets, indicated as Molecular Radiotherapy (MRT), or directly injected into the arteries that supply blood to liver tumour vasculature, indicated as Selective RT (SRT). The aim of this work is to offer a panoramic view on the increasing number of commercially-available TRT treatment planning systems (TPSs). MATERIALS AND METHODS A questionnaire was sent to manufacturers' representatives. Academic software were not considered. Questions were grouped as follows: general information, clinical workflow, calibration procedure, image processing/reconstruction, image registration and segmentation tools, time-activity curve (TAC) fitting and absorbed dose calculation. RESULTS All software reported have CE-marking. TPSs were divided between SRT-dedicated software [4] and MRT [5] dosimetry software. In SRT, since no kinetic process is involved, absorbed dose calculation does not require TAC fitting, and image registration is not fully developed in all TPS. All software requires a radionuclide-specific calibration. In SRT, a relative image calibration can be obtained by scaling the counts to a known activity. Automated VOI contouring and rigid/deformable propagation between different acquisitions time-points is implemented in most TPSs, although DICOM export is rare. Different TAC fits are available depending on the number of time-points. Voxel S-value and Local deposition methods are the most frequent dosimetric approaches; dose-voxel kernel convolution and semi-Monte Carlo method are also available. CONCLUSIONS Available TPSs allows performing personalized dosimetry in clinical practice. Individual variations in methodology/algorithms must be considered in the standardisation/harmonization processes.
Collapse
Affiliation(s)
- Giuseppe Della Gala
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Manuel Bardiès
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier (ICM), Montpellier F-34298, France; IRCM, UMR 1194 INSERM, Université de Montpellier and Institut Régional du Cancer de Montpellier (ICM), Montpellier F-34298, France
| | - Jill Tipping
- The Christie NHS Foundation Trust, Manchester, UK
| | - Lidia Strigari
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
| |
Collapse
|
17
|
Yoo MY, Paeng JC, Kim HC, Lee MS, Lee JS, Lee DS, Kang KW, Cheon GJ. Efficacy of voxel-based dosimetry map for predicting response to trans-arterial radioembolization therapy for hepatocellular carcinoma: a pilot study. Nucl Med Commun 2021; 42:1396-1403. [PMID: 34392298 DOI: 10.1097/mnm.0000000000001471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE Typical clinical dosimetry models for trans-arterial radioembolization (TARE) assume uniform dose distribution in each tissue compartment. We performed simple voxel-based dosimetry using post-treatment 90Y PET following TARE with 90Y-resin microspheres and investigated its prognostic value in a pilot cohort. METHOD Ten patients with 14 hepatocellular carcinoma lesions who underwent TARE with 90Y-resin microspheres were retrospectively included. The partition model-based expected target tumor dose (TDp) was calculated using a pretreatment 99mTc-macroaggregated albumin scan. From post-treatment 90Y-microsphere PET and voxel-wise S-value kernels, voxel-based dose maps were produced and the absorbed dose of each lesion (TDv) was calculated. Heterogeneity of intratumoral absorbed doses was assessed using the SD and coefficient of variation of voxel doses. The response of each lesion was determined based on contrast-enhanced MRI or CT, or both. Lesion responses were classified as local control success or failure. Prognostic values of dosimetry parameters and clinicopathological factors were evaluated in terms of progression-free survival (PFS) of each lesion. RESULTS TDv was significantly different between local control success and failure groups, whereas tumor size, TDp and intratumoral dose heterogeneity were not. Univariate survival analysis identified serum aspartate transaminase level ≥40 IU/L, tumor size ≥66 mm and TDv <81 Gy as significant prognostic factors for PFS. However, only TDv was an independent predictive factor in the multivariate analysis (P = 0.022). There was a significant correlation between TDv and PFS (P = 0.009; r = 0.669). CONCLUSIONS In TARE, voxel-based dose index TDv can be estimated on post-treatment 90Y PET using a simple method. TDv was a more effective prognostic factor for TARE than TDp and clinicopathologic factors in this pilot study. Further studies are warranted on the role of voxel-based dose and dose distribution in TARE.
Collapse
Affiliation(s)
- Min Young Yoo
- Departments of Nuclear Medicine, Chungbuk National University Hospital, Cheongju
| | - Jin Chul Paeng
- Department of Nuclear Medicine, Seoul National University Hospital
| | - Hyo-Cheol Kim
- Department of Radiology, Seoul National University Hospital
| | - Min Sun Lee
- Department of Nuclear Medicine, Seoul National University Hospital
- Interdisciplinary Program in Radiation Applied Life Science, Seoul National University, Seoul
- Nuclear Emergency and Environmental Protection Division, Korea Atomic Energy Research Institute, Daejeon
| | - Jae Sung Lee
- Department of Nuclear Medicine, Seoul National University Hospital
- Interdisciplinary Program in Radiation Applied Life Science, Seoul National University, Seoul
- Department of Biomedical Sciences, Seoul National University College of Medicine
| | - Dong Soo Lee
- Department of Nuclear Medicine, Seoul National University Hospital
- Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul National University, Seoul
| | - Keon Wook Kang
- Department of Nuclear Medicine, Seoul National University Hospital
- Cancer Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Gi Jeong Cheon
- Department of Nuclear Medicine, Seoul National University Hospital
- Cancer Research Institute, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
18
|
Chiesa C, Sjogreen-Gleisner K, Walrand S, Strigari L, Flux G, Gear J, Stokke C, Gabina PM, Bernhardt P, Konijnenberg M. EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres. EJNMMI Phys 2021; 8:77. [PMID: 34767102 PMCID: PMC8589932 DOI: 10.1186/s40658-021-00394-3] [Citation(s) in RCA: 59] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 06/21/2021] [Indexed: 11/27/2022] Open
Abstract
The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in 90Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of 99mTc albumin macro-aggregates (MAA) and 90Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between 99mTc-MAA predictions and actual 90Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments.Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected 99mTc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and 90Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected 99mTc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative 90Y bremsstrahlung SPECT can be used if dedicated correction methods are available.The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
Collapse
Affiliation(s)
- Carlo Chiesa
- Nuclear Medicine Unit, Foundation IRCCS Istituto Nazionale Tumori, Milan, Italy
| | | | - Stephan Walrand
- Nuclear Medicine, Molecular Imaging, Radiotherapy and Oncology Unit (MIRO), IECR, Université Catholique de Louvain, Brussels, Belgium
| | - Lidia Strigari
- Medical Physics Division, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Glenn Flux
- Joint Department of Physics, Royal Marsden Hospital & Institute of Cancer Research, Sutton, UK
| | - Jonathan Gear
- Joint Department of Physics, Royal Marsden Hospital & Institute of Cancer Research, Sutton, UK
| | - Caroline Stokke
- Department of Diagnostic Physics, Oslo University Hospital, Oslo, Norway
| | - Pablo Minguez Gabina
- Department of Medical Physics and Radiation Protection, Gurutzeta/Cruces University Hospital, Barakaldo, Spain
| | - Peter Bernhardt
- Department of Radiation Physics, Institute of Clinical Science, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Mark Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.
| |
Collapse
|
19
|
Kim SP, Juneau D, Cohalan C, Enger SA. Standardizing SPECT/CT dosimetry following radioembolization with yttrium-90 microspheres. EJNMMI Phys 2021; 8:71. [PMID: 34716850 PMCID: PMC8557238 DOI: 10.1186/s40658-021-00413-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 09/10/2021] [Indexed: 12/19/2022] Open
Abstract
Background Multiple post-treatment dosimetry methods are currently under investigation for Yttrium-90 (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$^{90}\hbox {Y}$$\end{document}90Y) radioembolization. Within each methodology, a variety of dosimetric inputs exists that affect the final dose estimates. Understanding their effects is essential to facilitating proper dose analysis and crucial in the eventual standardization of radioembolization dosimetry. The purpose of this study is to investigate the dose differences due to different self-calibrations and mass density assignments in the non-compartmental and local deposition methods. A practical mean correction method was introduced that permits dosimetry in images where the quality is compromised by patient motion and partial volume effects. Methods Twenty-one patients underwent \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$^{90}\hbox {Y}$$\end{document}90Y radioembolization and were imaged with SPECT/CT. Five different self-calibrations (FOV, Body, OAR, Liverlung, and Liver) were implemented and dosimetrically compared. The non-compartmental and local deposition method were used to perform dosimetry based on either nominal- or CT calibration-based mass densities. A mean correction method was derived assuming homogeneous densities. Cumulative dose volume histograms, linear regressions, boxplots, and Bland Altman plots were utilized for analysis. Results Up to 270% weighted dose difference was found between self-calibrations with mean dose differences up to 50 Gy in the liver and 23 Gy in the lungs. Between the local deposition and non-compartmental methods, the liver and lung had dose differences within 0.71 Gy and 20 Gy, respectively. The local deposition method’s nominal and CT calibration-based mass density implementations dosimetric metrics were within 1.4% in the liver and 24% in the lungs. The mean lung doses calculated with the CT method were shown to be inflated. The mean correction method demonstrated that the corrected mean doses were greater by up to \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\sim 5$$\end{document}∼5 Gy in the liver and lower by up to \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\sim 12$$\end{document}∼12 Gy in the lungs. Conclusions The OAR calibration may be utilized as a potentially more accurate and precise self-calibration. The non-compartmental method was found more comparable to the local deposition method in organs that were more homogeneous in mass densities. Due to the potential for inflated lung mean doses, the non-compartmental and local deposition method implemented with nominal mass densities is recommended for more consistent dosimetric results. If patient motion and partial volume effects are present in the liver, our practical correction method will calculate more representative doses in images suboptimal for dosimetry.
Collapse
Affiliation(s)
- S Peter Kim
- Medical Physics Unit, McGill University, Montreal, Canada. .,Biological and Biomedical Engineering, McGill University, Montreal, Canada.
| | - Daniel Juneau
- Department of Medical Imaging, Centre Hospitalier de l'Université de Montréal, Montreal, Canada
| | - Claire Cohalan
- Department of Physics and Biomedical Engineering, Centre Hospitalier de l'Université de Montréal, Montreal, Canada
| | - Shirin A Enger
- Medical Physics Unit, McGill University, Montreal, Canada.,Biological and Biomedical Engineering, McGill University, Montreal, Canada.,Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, Canada
| |
Collapse
|
20
|
Hesse M, d'Abadie P, Lhommel R, Jamar F, Walrand S. Yttrium-90 TOF-PET-Based EUD Predicts Response Post Liver Radioembolizations Using Recommended Manufacturer FDG Reconstruction Parameters. Front Oncol 2021; 11:592529. [PMID: 34676157 PMCID: PMC8523947 DOI: 10.3389/fonc.2021.592529] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Accepted: 09/07/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose Explaining why 90Y TOF-PET based equivalent uniform dose (EUD) using recommended manufacturer FDG reconstruction parameters has been shown to predict response. Methods The hot rods insert of a Jaszczak deluxe phantom was partially filled with a 2.65 GBq 90Y - 300ml DTPA water solution resulting in a 100 Gy mean absorbed dose in the 6 sectors. A two bed 20min/position acquisition was performed on a 550ps- and on a 320ps- TOF-PET/CT and reconstructed with recommended manufacturer FDG reconstruction parameters, without and with additional filtering. The whole procedure was repeated on both PET after adding 300ml of water (50Gy setup). The phantom was acquired again after decay by a factor of 10 (5Gy setup), but with 200min per bed position. For comparison, the phantom was also acquired with 18F activity corresponding to a clinical FDG whole body acquisition. Results The 100Gy-setup provided a hot rod sectors image almost as good as the 18F phantom. However, despite acquisition time compensation, the 5Gy-setup provides much lower quality imaging. TOF-PET based sectors EUDs for the three large rod sectors agreed with the actual EUDs computed with a radiosensitivity of 0.021Gy-1 well in the range observed in external beam radiotherapy (EBRT), i.e. 0.01-0.04Gy-1. This agreement explains the reunification of the dose-response relationships of the glass and resin spheres in HCC using the TOF-PET based EUD. Additional filtering reduced the EUDs agreement quality. Conclusions Recommended manufacturer FDG reconstruction parameters are suitable in TOF-PET post 90Y liver radioembolization for accurate tumour EUD computation. The present results rule out the use of low specific activity phantom studies to optimize reconstruction parameters.
Collapse
Affiliation(s)
- Michel Hesse
- Nuclear Medicine, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Philipe d'Abadie
- Nuclear Medicine, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Renaud Lhommel
- Nuclear Medicine, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Francois Jamar
- Nuclear Medicine, Cliniques universitaires Saint-Luc, Brussels, Belgium
| | - Stephan Walrand
- Nuclear Medicine, Cliniques universitaires Saint-Luc, Brussels, Belgium
| |
Collapse
|
21
|
Georgiou MF, Kuker RA, Studenski MT, Ahlman PP, Witte M, Portelance L. Lung shunt fraction calculation using 99mTc-MAA SPECT/CT imaging for 90Y microsphere selective internal radiation therapy of liver tumors. EJNMMI Res 2021; 11:96. [PMID: 34585259 PMCID: PMC8479035 DOI: 10.1186/s13550-021-00837-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Accepted: 09/11/2021] [Indexed: 01/16/2023] Open
Abstract
BACKGROUND 99mTc-macroaggregated albumin (99mTc-MAA) scintigraphy is utilized in treatment planning for Yttrium-90 (90Y) Selective Internal Radiation Therapy (SIRT) of liver tumors to evaluate hepatopulmonary shunting by calculating the lung shunt fraction (LSF). The purpose of this study was to evaluate if LSF calculation using SPECT/CT instead of planar gamma camera imaging is more accurate and if this can potentially lead to more effective treatment planning of hepatic lesions while avoiding excessive pulmonary irradiation. RESULTS LSF calculation was obtained using two different methodologies in 85 cases from consecutive patients intended to receive 90Y SIRT. The first method was based on planar gamma camera imaging in the anterior and posterior views with geometric mean calculation of the LSF from regions of interest of the liver and lungs. The second method was based on segmentation of the liver and lungs from SPECT/CT images of the thorax and abdomen. The differences in planar imaging versus SPECT/CT derived LSF values along with the estimated absorbed lung mean dose (LMD) were evaluated. The LSF values were higher in planar imaging versus SPECT/CT in 81/85 cases, with a mean value of 8.5% vs. 4.6% respectively; the difference was statistically significant using a paired t-test (alpha = 0.05). In those patients who received SIRT, the estimated absorbed LMD calculated with planar imaging was significantly higher than with SPECT/CT (t-test, P < 0.005). Repeated phantom experiments using an anthropomorphic torso phantom with variable 99mTc activity concentrations for the liver and lungs were performed with the standard patient protocol, demonstrated improved accuracy of the LSF calculation based on SPECT/CT than planar imaging (mean overestimated value of 6% vs. 26%). CONCLUSIONS This study demonstrates that LSF calculation using planar imaging can be significantly overestimated while calculation using SPECT/CT imaging and appropriate segmentation tools can be more accurate. Minimizing the errors in obtaining the LSF can lead to more effective 90Y SIRT treatment planning for hepatic tumors while ensuring the lung dose will not exceed the standard acceptable safety thresholds.
Collapse
Affiliation(s)
- Mike F Georgiou
- Department of Radiology, Miller School of Medicine, University of Miami, 1611 NW 12th Avenue, JMH C-248, Miami, FL, 33136, USA.
| | - Russ A Kuker
- Department of Radiology, Miller School of Medicine, University of Miami, 1611 NW 12th Avenue, JMH C-248, Miami, FL, 33136, USA
| | - Matthew T Studenski
- Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL, USA
| | - Preeti P Ahlman
- Department of Radiology, Miller School of Medicine, University of Miami, 1611 NW 12th Avenue, JMH C-248, Miami, FL, 33136, USA
| | - Megan Witte
- Department of Biomedical Engineering, University of Miami, Miami, FL, USA
| | - Lorraine Portelance
- Department of Radiation Oncology, Miller School of Medicine, University of Miami, Miami, FL, USA
| |
Collapse
|
22
|
Labour J, Boissard P, Baudier T, Khayi F, Kryza D, Durebex PV, Martino SPD, Mognetti T, Sarrut D, Badel JN. Yttrium-90 quantitative phantom study using digital photon counting PET. EJNMMI Phys 2021; 8:56. [PMID: 34318383 PMCID: PMC8316557 DOI: 10.1186/s40658-021-00402-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 06/23/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND PET imaging of 90Y-microsphere distribution following radioembolisation is challenging due to the count-starved statistics from the low branching ratio of e+/e- pair production during 90Y decay. PET systems using silicon photo-multipliers have shown better 90Y image quality compared to conventional photo-multiplier tubes. The main goal of the present study was to evaluate reconstruction parameters for different phantom configurations and varying listmode acquisition lengths to improve quantitative accuracy in 90Y dosimetry, using digital photon counting PET/CT. METHODS Quantitative PET and dosimetry accuracy were evaluated using two uniform cylindrical phantoms specific for PET calibration validation. A third body phantom with a 9:1 hot sphere-to-background ratio was scanned at different activity concentrations of 90Y. Reconstructions were performed using OSEM algorithm with varying parameters. Time-of-flight and point-spread function modellings were included in all reconstructions. Absorbed dose calculations were carried out using voxel S-values convolution and were compared to reference Monte Carlo simulations. Dose-volume histograms and root-mean-square deviations were used to evaluate reconstruction parameter sets. Using listmode data, phantom and patient datasets were rebinned into various lengths of time to assess the influence of count statistics on the calculation of absorbed dose. Comparisons between the local energy deposition method and the absorbed dose calculations were performed. RESULTS Using a 2-mm full width at half maximum post-reconstruction Gaussian filter, the dosimetric accuracy was found to be similar to that found with no filter applied but also reduced noise. Larger filter sizes should not be used. An acquisition length of more than 10 min/bed reduces image noise but has no significant impact in the quantification of phantom or patient data for the digital photon counting PET. 3 iterations with 10 subsets were found suitable for large spheres whereas 1 iteration with 30 subsets could improve dosimetry for smaller spheres. CONCLUSION The best choice of the combination of iterations and subsets depends on the size of the spheres. However, one should be careful on this choice, depending on the imaging conditions and setup. This study can be useful in this choice for future studies for more accurate 90Y post-dosimetry using a digital photon counting PET/CT.
Collapse
Affiliation(s)
- Joey Labour
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | | | - Thomas Baudier
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Fouzi Khayi
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - David Kryza
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
- Hospices Civils de Lyon; Université de Lyon; Université Claude Bernard Lyon 1; LAGEPP UMR 5007 CNRS, Lyon, France
| | | | | | | | - David Sarrut
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Jean-Noël Badel
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| |
Collapse
|
23
|
Nodari G, Popoff R, Riedinger JM, Lopez O, Pellegrinelli J, Dygai-Cochet I, Tabouret-Viaud C, Presles B, Chevallier O, Gehin S, Gallet M, Latournerie M, Manfredi S, Loffroy R, Vrigneaud JM, Cochet A. Impact of contouring methods on pre-treatment and post-treatment dosimetry for the prediction of tumor control and survival in HCC patients treated with selective internal radiation therapy. EJNMMI Res 2021; 11:24. [PMID: 33687596 PMCID: PMC7943673 DOI: 10.1186/s13550-021-00766-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 02/23/2021] [Indexed: 12/16/2022] Open
Abstract
INTRODUCTION The aim of this study was to evaluate the impact of the contouring methods on dose metrics and their predictive value on tumor control and survival, in both situations of pre-treatment and post-treatment dosimetry, for patients with advanced HCC treated with SIRT. METHODS Forty-eight patients who underwent SIRT between 2012 and 2020 were retrospectively included in this study. Target volumes were delineated using two methods: MRI-based contours manually drawn by a radiologist and then registered on SPECT/CT and PET/CT via deformable registration (Pre-CMRI and Post-CMRI), 99mTc-MAA-SPECT and 90Y-microspheres-PET 10% threshold contouring (Pre-CSPECT and Post-CPET). The mean absorbed dose (Dm) and the minimal absorbed dose delivered to 70% of the tumor volume (D70) were evaluated with both contouring methods; the tumor-to-normal liver uptake ratio (TNR) was evaluated with MRI-based contours only. Tumor response was assessed using the mRECIST criteria on the follow-up MRIs. RESULTS No significant differences were found for Dm and TNR between pre- and post-treatment. TNR evaluated with radiologic contours (Pre-CMRI and Post-CMRI) were predictive of tumor control at 6 months on pre- and post-treatment dosimetry (OR 5.9 and 7.1, respectively; p = 0.02 and 0.01). All dose metrics determined with both methods were predictive of overall survival (OS) on pre-treatment dosimetry, but only Dm with MRI-based contours was predictive of OS on post-treatment images with a median of 23 months for patients with a supramedian Dm versus 14 months for the others (p = 0.04). CONCLUSION In advanced HCC treated with SIRT, Dm and TNR determined with radiologic contours were predictive of tumor control and OS. This study shows that a rigorous clinical workflow (radiologic contours + registration on scintigraphic images) is feasible and should be prospectively considered for improving therapeutic strategy.
Collapse
Affiliation(s)
- Guillaume Nodari
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.
| | - Romain Popoff
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Jean Marc Riedinger
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | - Olivier Lopez
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Julie Pellegrinelli
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Inna Dygai-Cochet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | | | - Benoit Presles
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Olivier Chevallier
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France.,Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Sophie Gehin
- Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Matthieu Gallet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France
| | | | - Sylvain Manfredi
- Department of Gastroenterology, University Hospital Dijon, Dijon, France
| | - Romaric Loffroy
- ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France.,Department of Vascular and Interventional Radiology, University Hospital Dijon, Dijon, France
| | - Jean Marc Vrigneaud
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| | - Alexandre Cochet
- Department of Nuclear Medicine, Centre Georges-François Leclerc, Dijon, France.,ImViA Laboratory, IFTIM Team, EA 7535, University of Burgundy, Dijon, France
| |
Collapse
|
24
|
Zhang JW, Yu ZY, Li HB, Yi SH, Liu W, Yang Y, Wang GY. Severe bile duct complication after yttrium-90 radioembolization therapy in a patient with recurrent hepatocellular carcinoma after liver transplantation: A case report. LIVER RESEARCH 2021. [DOI: 10.1016/j.livres.2020.10.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
25
|
Relationship of radiation dose to efficacy of radioembolization of liver metastasis from breast cancer. Eur J Radiol 2021; 136:109539. [PMID: 33476965 DOI: 10.1016/j.ejrad.2021.109539] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 12/07/2020] [Accepted: 01/06/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE To determine the relationship of tumoral and nontumoral radiation dose to response and toxicity after transarterial radioembolization (TARE) of breast cancer liver metastasis. METHODS This retrospective study evaluated all patients with breast cancer liver metastases treated with TARE (2/2011-6/2019). Extent of disease was measured as unilobar or bilobar on baseline PET/CT prior to TARE. Response was assessed for targeted regions with modified PERCIST criteria on first follow-up PET/CT. Tumoral and nontumoral liver dosimetry was evaluated by performing volumetric segmentation on post-TARE Bremsstrahlung SPECT/CT. ≥Grade 3 hepatotoxicity was defined as ≥grade 3 bilirubin/AST/ALT elevation or ascites requiring intervention. Fisher's exact tests, Wilcoxon rank sum tests, and Kaplan-Meier survival analysis were performed. RESULTS Among 64 women, 60 patients had pre- and post-TARE PET/CT, of whom 46/60 (77 %) achieved objective response (OR). Responders received higher tumoral dose with a median (interquartile range) of 167 (96-217) vs. 54 (45-62) Gy (p < 0.001). ≥Grade 3 hepatotoxicity occurred in 8/64 (12.5 %) and was associated with higher pre-treatment bilirubin levels of 0.9 (0.9-1.1) vs. 0.5 (0.4-0.7) mg/dL (p = 0.013). Median overall survival (OS) was 11 (95 % CI 10-19) months. Bilobar disease (Hazard Ratio [HR]: 2.77, 95 % CI 1.11-6.89, p = 0.028) and elevated pre-TARE AST (HR 1.02, 95 % CI 1.01-1.03, p < 0.001) were independently associated with shorter survival. ≥Grade 3 hepatotoxicity was associated with reduced survival (p < 0.001). OR was associated with longer OS of 17 months, compared with 10 months (p = 0.027). CONCLUSION In TARE for breast cancer liver metastasis, higher tumoral radiation dose (>79.5 Gy) was associated with OR, which was associated with longer survival. Pre-existing liver dysfunction was associated with hepatotoxicity, which was associated with decreased survival.
Collapse
|
26
|
Santoro L, Pitalot L, Trauchessec D, Mora-Ramirez E, Kotzki PO, Bardiès M, Deshayes E. Clinical implementation of PLANET® Dose for dosimetric assessment after [ 177Lu]Lu-DOTA-TATE: comparison with Dosimetry Toolkit® and OLINDA/EXM® V1.0. EJNMMI Res 2021; 11:1. [PMID: 33394212 PMCID: PMC7782649 DOI: 10.1186/s13550-020-00737-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Accepted: 11/23/2020] [Indexed: 01/03/2023] Open
Abstract
Background The aim of this study was to compare a commercial dosimetry workstation (PLANET® Dose) and the dosimetry approach (GE Dosimetry Toolkit® and OLINDA/EXM® V1.0) currently used in our department for quantification of the absorbed dose (AD) to organs at risk after peptide receptor radionuclide therapy with [177Lu]Lu-DOTA-TATE. Methods An evaluation on phantom was performed to determine the SPECT calibration factor variations over time and to compare the Time Integrated Activity Coefficients (TIACs) obtained with the two approaches. Then, dosimetry was carried out with the two tools in 21 patients with neuroendocrine tumours after the first and second injection of 7.2 ± 0.2 GBq of [177Lu]Lu-DOTA-TATE (40 dosimetry analyses with each software). SPECT/CT images were acquired at 4 h, 24 h, 72 h and 192 h post-injection and were reconstructed using the Xeleris software (General Electric). The liver, spleen and kidneys masses and TIACs were determined using Dosimetry Toolkit® (DTK) and PLANET® Dose. The ADs were calculated using OLINDA/EXM® V1.0 and the Local Deposition Method (LDM) or Dose voxel-Kernel convolution (DK) on PLANET® Dose. Results With the phantom, the 3D calibration factors showed a slight variation (0.8% and 3.3%) over time, and TIACs of 225.19 h and 217.52 h were obtained with DTK and PLANET® Dose, respectively. In patients, the root mean square deviation value was 8.9% for the organ masses, 8.1% for the TIACs, and 9.1% and 7.8% for the ADs calculated with LDM and DK, respectively. The Lin’s concordance correlation coefficient was 0.99 and the Bland–Altman plot analysis estimated that the AD value difference between methods ranged from − 0.75 to 0.49 Gy, from − 0.20 to 0.64 Gy, and from − 0.43 to 1.03 Gy for 95% of the 40 liver, kidneys and spleen dosimetry analyses. The dosimetry method had a minor influence on AD differences compared with the image registration and organ segmentation steps. Conclusions The ADs to organs at risk obtained with the new workstation PLANET® Dose are concordant with those calculated with the currently used software and in agreement with the literature. These results validate the use of PLANET® Dose in clinical routine for patient dosimetry after targeted radiotherapy with [177Lu]Lu-DOTA-TATE.
Collapse
Affiliation(s)
- Lore Santoro
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), Univ. Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex 5, France.
| | - L Pitalot
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), Univ. Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex 5, France
| | - D Trauchessec
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), Univ. Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex 5, France
| | - E Mora-Ramirez
- Centre de Recherche en Cancérologie de Toulouse, Toulouse, France.,INSERM, UMR 1037, Toulouse III Paul Sabatier University, Toulouse, France.,University of Costa Rica, Physics School, CICANUM, San José, Costa Rica
| | - P O Kotzki
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), Univ. Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex 5, France.,Montpellier Cancer Research Institute, UMR 1194, Univ. Montpellier, Montpellier, France
| | - M Bardiès
- Centre de Recherche en Cancérologie de Toulouse, Toulouse, France.,INSERM, UMR 1037, Toulouse III Paul Sabatier University, Toulouse, France
| | - E Deshayes
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), Univ. Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex 5, France.,Montpellier Cancer Research Institute, UMR 1194, Univ. Montpellier, Montpellier, France
| |
Collapse
|
27
|
Abstract
Radiopharmaceutical therapy (RPT) has grown rapidly over the last decade for treatment of numerous cancer types. Dosimetric guidance, as with other radiotherapy modalities, has benefitted patients by reducing the incidence of side effects and improving overall survival in populations treated under this paradigm. Development of tools and techniques for dosimetry-guided therapy is ongoing, with numerous the Food and Drug Administration-cleared products reaching the U.S. market in 2019. Safe use of commercial dosimetry platforms requires a deep understanding of the underlying physical principles and thoroughly vetted input data. Likewise, interpretation of dosimetry results relies on an understanding of radiobiological principles, and the principles of uncertainty propagation. In this article, we review strategies commonly employed for dosimetry-guided RPT - including quantitative imaging, dose calculation methods, and modeling of dose across time-points. Additionally, we review recent literature evidence (2013-2020) demonstrating the efficacy of personalized RPT.
Collapse
Affiliation(s)
| | - Robert F Hobbs
- Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD
| |
Collapse
|
28
|
Craig AJ, Rojas B, Wevrett JL, Hamer E, Fenwick A, Gregory R. IPEM topical report: current molecular radiotherapy service provision and guidance on the implications of setting up a dosimetry service. Phys Med Biol 2020; 65:245038. [PMID: 33142274 DOI: 10.1088/1361-6560/abc707] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Despite a growth in molecular radiotherapy treatment (MRT) and an increase in interest, centres still rarely perform MRT dosimetry. The aims of this report were to assess the main reasons why centres are not performing MRT dosimetry and provide advice on the resources required to set-up such a service. A survey based in the United Kingdom was developed to establish how many centres provide an MRT dosimetry service and the main reasons why it is not commonly performed. Twenty-eight per cent of the centres who responded to the survey performed some form of dosimetry, with 88% of those centres performing internal dosimetry. The survey showed that a 'lack of clinical evidence', a 'lack of guidelines' and 'not current UK practice' were the largest obstacles to setting up an MRT dosimetry service. More practical considerations, such as 'lack of software' and 'lack of staff training/expertise', were considered to be of lower significance by the respondents. Following on from the survey, this report gives an overview of the current guidelines, and the evidence available demonstrating the benefits of performing MRT dosimetry. The resources required to perform such techniques are detailed with reference to guidelines, training resources and currently available software. It is hoped that the information presented in this report will allow MRT dosimetry to be performed more frequently and in more centres, both in routine clinical practice and in multicentre trials. Such trials are required to harmonise dosimetry techniques between centres, build on the current evidence base, and provide the data necessary to establish the dose-response relationship for MRT.
Collapse
Affiliation(s)
- Allison J Craig
- Joint Department of Physics, Royal Marsden NHSFT, Sutton, United Kingdom. The Institute of Cancer Research, London, United Kingdom. Author to whom any correspondence should be addressed
| | | | | | | | | | | |
Collapse
|
29
|
Morán V, Prieto E, Sancho L, Rodríguez-Fraile M, Soria L, Zubiria A, Martí-Climent JM. Impact of the dosimetry approach on the resulting 90Y radioembolization planned absorbed doses based on 99mTc-MAA SPECT-CT: is there agreement between dosimetry methods? EJNMMI Phys 2020; 7:72. [PMID: 33284389 PMCID: PMC7721939 DOI: 10.1186/s40658-020-00343-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Accepted: 11/24/2020] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Prior radioembolization, a simulation using 99mTc-macroaggregated albumin as 90Y-microspheres surrogate is performed. Gamma scintigraphy images (planar, SPECT, or SPECT-CT) are acquired to evaluate intrahepatic 90Y-microspheres distribution and detect possible extrahepatic and lung shunting. These images may be used for pre-treatment dosimetry evaluation to calculate the 90Y activity that would get an optimal tumor response while sparing healthy tissues. Several dosimetry methods are available, but there is still no consensus on the best methodology to calculate absorbed doses. The goal of this study was to retrospectively evaluate the impact of using different dosimetry approaches on the resulting 90Y-radioembolization pre-treatment absorbed dose evaluation based on 99mTc-MAA images. METHODS Absorbed doses within volumes of interest resulting from partition model (PM) and 3D voxel dosimetry methods (3D-VDM) (dose-point kernel convolution and local deposition method) were evaluated. Additionally, a new "Multi-tumor Partition Model" (MTPM) was developed. The differences among dosimetry approaches were evaluated in terms of mean absorbed dose and dose volume histograms within the volumes of interest. RESULTS Differences in mean absorbed dose among dosimetry methods are higher in tumor volumes than in non-tumoral ones. The differences between MTPM and both 3D-VDM were substantially lower than those observed between PM and any 3D-VDM. A poor correlation and concordance were found between PM and the other studied dosimetry approaches. DVH obtained from either 3D-VDM are pretty similar in both healthy liver and individual tumors. Although no relevant global differences, in terms of absorbed dose in Gy, between both 3D-VDM were found, important voxel-by-voxel differences have been observed. CONCLUSIONS Significant differences among the studied dosimetry approaches for 90Y-radioembolization treatments exist. Differences do not yield a substantial impact in treatment planning for healthy tissue but they do for tumoral liver. An individual segmentation and evaluation of the tumors is essential. In patients with multiple tumors, the application of PM is not optimal and the 3D-VDM or the new MTPM are suggested instead. If a 3D-VDM method is not available, MTPM is the best option. Furthermore, both 3D-VDM approaches may be indistinctly used.
Collapse
Affiliation(s)
- Verónica Morán
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Madrid, Spain
| | - Elena Prieto
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Pamplona, Spain.,IdisNA, Navarra Institute for Health Research, Pamplona, Spain
| | - Lidia Sancho
- Department of Nuclear Medicine, Clínica Universidad de Navarra, Madrid, Spain
| | - Macarena Rodríguez-Fraile
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Pamplona, Spain.,Department of Nuclear Medicine, Clínica Universidad de Navarra, Pamplona, Spain
| | - Leticia Soria
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Madrid, Spain
| | - Arantxa Zubiria
- Department of Radiation Oncology, Clínica Universidad de Navarra, Pamplona, Spain
| | - Josep M Martí-Climent
- Department of Medical Physics and Radiation Safety, Clínica Universidad de Navarra, Pamplona, Spain. .,IdisNA, Navarra Institute for Health Research, Pamplona, Spain.
| |
Collapse
|
30
|
Brosch J, Gosewisch A, Kaiser L, Seidensticker M, Ricke J, Zellmer J, Bartenstein P, Ziegler S, Ilhan H, Todica A, Böning G. 3D image-based dosimetry for Yttrium-90 radioembolization of hepatocellular carcinoma: Impact of imaging method on absorbed dose estimates. Phys Med 2020; 80:317-326. [PMID: 33248338 DOI: 10.1016/j.ejmp.2020.11.016] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 11/09/2020] [Accepted: 11/11/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND To improve therapy outcome of Yttrium-90 selective internal radiation therapy (90Y SIRT), patient-specific post-therapeutic dosimetry is required. For this purpose, various dosimetric approaches based on different available imaging data have been reported. The aim of this work was to compare post-therapeutic 3D absorbed dose images using Technetium-99m (99mTc) MAA SPECT/CT, Yttrium-90 (90Y) bremsstrahlung (BRS) SPECT/CT, and 90Y PET/CT. METHODS Ten SIRTs of nine patients with unresectable hepatocellular carcinoma (HCC) were investigated. The 99mTc SPECT/CT data, obtained from 99mTc-MAA-based treatment simulation prior to 90Y SIRT, were scaled with the administered 90Y therapy activity. 3D absorbed dose images were generated by dose kernel convolution with scaled 99mTc/90Y SPECT/CT, 90Y BRS SPECT/CT, and 90Y PET/CT data of each patient. Absorbed dose estimates in tumor and healthy liver tissue obtained using the two SPECT/CT methods were compared against 90Y PET/CT. RESULTS The percentage deviation of tumor absorbed dose estimates from 90Y PET/CT values was on average -2 ± 18% for scaled 99mTc/90Y SPECT/CT, whereas estimates from 90Y BRS SPECT/CT differed on average by -50 ± 13%. For healthy liver absorbed dose estimates, all three imaging methods revealed comparable values. CONCLUSION The quantification capabilities of the imaging data influence 90Y SIRT tumor dosimetry, while healthy liver absorbed dose values were comparable for all investigated imaging data. When no 90Y PET/CT image data are available, the proposed scaled 99mTc/90Y SPECT/CT dosimetry method was found to be more appropriate for HCC tumor dosimetry than 90Y BRS SPECT/CT based dosimetry.
Collapse
Affiliation(s)
- Julia Brosch
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany.
| | - Astrid Gosewisch
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Lena Kaiser
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Max Seidensticker
- Department of Radiology, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Jens Ricke
- Department of Radiology, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Johannes Zellmer
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Peter Bartenstein
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Sibylle Ziegler
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Harun Ilhan
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Andrei Todica
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| | - Guido Böning
- Department of Nuclear Medicine, University Hospital, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
31
|
Correlation and Agreement of Yttrium-90 Positron Emission Tomography/Computed Tomography with Ex Vivo Radioembolization Microsphere Deposition in the Rabbit VX2 Liver Tumor Model. J Vasc Interv Radiol 2020; 32:23-32.e1. [PMID: 33189539 DOI: 10.1016/j.jvir.2020.09.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 08/14/2020] [Accepted: 09/03/2020] [Indexed: 01/14/2023] Open
Abstract
PURPOSE To demonstrate a stronger correlation and agreement of yttrium-90 (90Y) positron emission tomography (PET)/computed tomography (CT) measurements with explant liver tumor dosing compared with the standard model (SM) for radioembolization. MATERIALS AND METHODS Hepatic VX2 tumors were implanted into New Zealand white rabbits, with growth confirmed by 7 T magnetic resonance imaging. Seventeen VX2 rabbits provided 33 analyzed tumors. Treatment volumes were calculated from manually drawn volumes of interest (VOI) with three-dimensional surface renderings. Radioembolization was performed with glass 90Y microspheres. PET/CT imaging was completed with scatter and attenuation correction. Three-dimensional ellipsoid VOI were drawn to encompass tumors on fused images. Tumors and livers were then explanted for inductively coupled plasma (ICP)-optical emission spectroscopy (OES) analysis of microsphere content. 90Y PET/CT and SM measurements were compared with reference standard ICP-OES measurements of tumor dosing with Pearson correlation and Bland-Altman analyses for agreement testing with and without adjustment for tumor necrosis. RESULTS The median infused activity was 33.3 MBq (range, 5.9-152.9). Tumor dose was significantly correlated with 90Y PET/CT measurements (r = 0.903, P < .001) and SM estimates (r = 0.607, P < .001). Bland-Altman analyses showed that the SM tended to underestimate the tumor dosing by a mean of -8.5 Gy (CI, -26.3-9.3), and the degree of underestimation increased to a mean of -18.3 Gy (CI, -38.5-1.9) after the adjustment for tumor necrosis. CONCLUSIONS 90Y PET/CT estimates were strongly correlated and had better agreement with reference measurements of tumor dosing than SM estimates.
Collapse
|
32
|
Abbott EM, Falzone N, Lee BQ, Kartsonaki C, Winter H, Greenhalgh TA, McGowan DR, Syed N, Denis-Bacelar AM, Boardman P, Sharma RA, Vallis KA. The Impact of Radiobiologically Informed Dose Prescription on the Clinical Benefit of 90Y SIRT in Colorectal Cancer Patients. J Nucl Med 2020; 61:1658-1664. [PMID: 32358093 DOI: 10.2967/jnumed.119.233650] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 03/16/2020] [Indexed: 12/31/2022] Open
Abstract
The purpose of this study was to establish the dose-response relationship of selective internal radiation therapy (SIRT) in patients with metastatic colorectal cancer (mCRC), when informed by radiobiological sensitivity parameters derived from mCRC cell lines exposed to 90Y. Methods: Twenty-three mCRC patients with liver metastases refractory to chemotherapy were included. 90Y bremsstrahlung SPECT images were transformed into dose maps assuming the local dose deposition method. Baseline and follow-up CT scans were segmented to derive liver and tumor volumes. Mean, median, and D70 (minimum dose to 70% of tumor volume) values determined from dose maps were correlated with change in tumor volume and volumetric RECIST response using linear and logistic regression, respectively. Radiosensitivity parameters determined by clonogenic assays of mCRC cell lines HT-29 and DLD-1 after exposure to 90Y or external beam radiotherapy (EBRT; 6 MV photons) were used in biologically effective dose (BED) calculations. Results: Mean administered radioactivity was 1,469 ± 428 MBq (range, 847-2,185 MBq), achieving a mean absorbed radiation dose to tumor of 35.5 ± 9.4 Gy and mean normal liver dose of 26.4 ± 6.8 Gy. A 1.0 Gy increase in mean, median, and D70 absorbed dose was associated with a reduction in tumor volume of 1.8%, 1.8%, and 1.5%, respectively, and an increased probability of a volumetric RECIST response (odds ratio, 1.09, 1.09, and 1.10, respectively). Threshold mean, median and D70 doses for response were 48.3, 48.8, and 41.8 Gy, respectively. EBRT-equivalent BEDs for 90Y are up to 50% smaller than those calculated by applying protraction-corrected radiobiological parameters derived from EBRT alone. Conclusion: Dosimetric studies have assumed equivalence between 90Y SIRT and EBRT, leading to inflation of BED for SIRT and possible undertreatment. Radiobiological parameters for 90Y were applied to a BED model, providing a calculation method that has the potential to improve assessment of tumor control.
Collapse
Affiliation(s)
- Elliot M Abbott
- Oxford Institute for Radiation Oncology, Department of Oncology, Oxford University, Oxford, United Kingdom
| | - Nadia Falzone
- Oxford Institute for Radiation Oncology, Department of Oncology, Oxford University, Oxford, United Kingdom
| | - Boon Q Lee
- Oxford Institute for Radiation Oncology, Department of Oncology, Oxford University, Oxford, United Kingdom
| | | | - Helen Winter
- Department of Oncology, Oxford University, Oxford, United Kingdom
| | | | - Daniel R McGowan
- Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Nigar Syed
- Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | | | - Philip Boardman
- Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Ricky A Sharma
- Radiation Oncology, University College London, London, United Kingdom
| | - Katherine A Vallis
- Oxford Institute for Radiation Oncology, Department of Oncology, Oxford University, Oxford, United Kingdom
| |
Collapse
|
33
|
Thomas MA, Mahvash A, Abdelsalam M, Kaseb AO, Kappadath SC. Planning dosimetry for 90 Y radioembolization with glass microspheres: Evaluating the fidelity of 99m Tc-MAA and partition model predictions. Med Phys 2020; 47:5333-5342. [PMID: 32790882 DOI: 10.1002/mp.14452] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 07/12/2020] [Accepted: 07/30/2020] [Indexed: 01/10/2023] Open
Abstract
PURPOSE 99m Tc-MAA-SPECT/CT may be used in 90 Y-glass microsphere radioembolization treatment planning to assess perfused liver volumes and absorbed dose distributions. The partition model (PM) offers a more detailed planning dosimetry option beyond the single-compartment model more traditionally used in 90 Y radioembolization. As 90 Y radioembolization treatments shift toward activities and doses that aim to achieve tumor control, accurate and reliable treatment planning dosimetry for both tumors and normal liver (NL) becomes more critical. In this work, we explore the accuracy and precision of 90 Y dosimetry predictions from pretherapy 99m Tc-MAA and PM. METHODS Both PM and voxel dosimetry models were used to calculate tumor and NL mean doses using both planning 99m Tc-MAA and verification 90 Y-SPECT/CT in this retrospective analysis of hepatocellular carcinoma cases treated with glass microspheres (NCT01900002, n = 32). Linear regression models were developed at first access, and then later correct, the estimates by (a) 99m Tc-MAA for 90 Y voxel dosimetry and (b) 99m Tc-MAA PM for voxel dosimetry, separately for both tumors and NL. Bland-Altman analysis was then used to evaluate the accuracy and precision of the regression model predictions with the mean bias and 95% prediction intervals (PI, ±1.96σ). Two categories of cases were stratified (catheter matched vs catheter unmatched) by establishing the level of 99m Tc-MAA and 90 Y catheter position alignment. Only catheter-matched cases were included in the 99m Tc-MAA vs 90 Y voxel dosimetry comparison, while all cases were used to compare dosimetry models (PM vs voxel). RESULTS Half (16/32) of cases were deemed catheter matched. 99m Tc-MAA could reliably predict NL doses in catheter-matched cases after application of the linear model, with mean bias (PI) of -1% (±31%). PM was equivalent to voxel dosimetry for NL doses with mean bias (PI) of 0% (±1%). Even among catheter-matched cases, 99m Tc-MAA planning for 90 Y tumor voxel doses was poor, overestimating dose by an average of nearly 40%. Upon application of the linear model, 99m Tc-MAA predictions for 90 Y tumor voxel dose were only minimally biased (-4%) but possessed very large PI (±104%). PM predictions for tumor voxel dose using the linear model also showed small bias (-6%) but maintained similarly high PI of ±90%. Cases with tumors representing a large majority (>80%) of the total tumor volume demonstrated the best scenarios for 99m Tc-MAA and PM tumor dose predictions, with mean biases (PI) of -3% (±53%) and -4% (±21%), respectively. CONCLUSION The unconditional use of 99m Tc-MAA to predict 90 Y dosimetry across all cases is not recommended due to: (a) demonstrated the risk of unmatched catheter positions between procedures, and (b) large bias and uncertainty in 99m Tc-MAA predictions in cases with matched catheter locations. However, NL voxel dose predictions with 99m Tc-MAA are clinically viable and either PM or voxel dosimetry can be used to produce equivalent predictions. Both 99m Tc-MAA and PM can provide tumor dose predictions with potential clinical utility, but only in catheter-matched cases and with tumors comprising a clear majority (>80%) of the total tumor volume. These findings stratify the predictive fidelity of 99m Tc-MAA- and PM-based treatment planning for 90 Y dosimetry in improving treatment outcomes.
Collapse
Affiliation(s)
- M Allan Thomas
- Department of Imaging Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Armeen Mahvash
- Department of Interventional Radiology, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Mohamed Abdelsalam
- Department of Interventional Radiology, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Ahmed O Kaseb
- Department of GI Medical Oncology, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - S Cheenu Kappadath
- Department of Imaging Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| |
Collapse
|
34
|
Pasciak AS, Manupipatpong S, Hui FK, Gainsburg L, Krimins R, Zink MC, Brayton CF, Morris M, Sage J, Donahue DR, Dreher MR, Kraitchman DL, Weiss CR. Yttrium-90 radioembolization as a possible new treatment for brain cancer: proof of concept and safety analysis in a canine model. EJNMMI Res 2020; 10:96. [PMID: 32804262 PMCID: PMC7431501 DOI: 10.1186/s13550-020-00679-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/28/2020] [Indexed: 12/22/2022] Open
Abstract
Purpose To evaluate the safety, feasibility, and preliminary efficacy of yttrium-90 (90Y) radioembolization (RE) as a minimally invasive treatment in a canine model with presumed spontaneous brain cancers. Materials Three healthy research dogs (R1–R3) and five patient dogs with spontaneous intra-axial brain masses (P1–P5) underwent cerebral artery RE with 90Y glass microspheres (TheraSphere). 90Y-RE was performed on research dogs from the unilateral internal carotid artery (ICA), middle cerebral artery (MCA), and posterior cerebral artery (PCA) while animals with brain masses were treated from the ICA. Post-treatment 90Y PET/CT was performed along with serial neurological exams by a veterinary neurologist. One month after treatment, research dogs were euthanized and the brains were extracted and sent for microdosimetric and histopathologic analyses. Patient dogs received post-treatment MRI at 1-, 3-, and 6-month intervals with long-term veterinary follow-up. Results The average absorbed dose to treated tissue in R1–R3 was 14.0, 30.9, and 73.2 Gy, respectively, with maximum doses exceeding 1000 Gy. One month after treatment, research dog pathologic analysis revealed no evidence of cortical atrophy and rare foci consistent with chronic infarcts, e.g., < 2-mm diameter. Absorbed doses to masses in P1–P5 were 45.5, 57.6, 58.1, 45.4, and 64.1 Gy while the dose to uninvolved brain tissue was 15.4, 27.6, 19.2, 16.7, and 33.3 G, respectively. Among both research and patient animals, 6 developed acute neurologic deficits following treatment. However, in all surviving dogs, the deficits were transient resolving between 7 and 33 days post-therapy. At 1 month post-therapy, patient animals showed a 24–94% reduction in mass volume with partial response in P1, P3, and P4 at 6 months post-treatment. While P2 initially showed a response, by 5 months, the mass had advanced beyond pre-treatment size, and the dog was euthanized. Conclusion This proof of concept demonstrates the technical feasibility and safety of 90Y-RE in dogs, while preliminary, initial data on the efficacy of 90Y-RE as a potential treatment for brain cancer is encouraging.
Collapse
Affiliation(s)
- Alexander S Pasciak
- School of Medicine, The Johns Hopkins University School of Medicine, 1800 Orleans St, Baltimore, MD, 21287, USA.
| | - Sasicha Manupipatpong
- School of Medicine, The Johns Hopkins University School of Medicine, 1800 Orleans St, Baltimore, MD, 21287, USA
| | - Ferdinand K Hui
- Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Larry Gainsburg
- Mid-Atlantic Veterinary Neurology and Neurosurgery, Baltimore, MD, USA
| | - Rebecca Krimins
- Department of Molecular and Comparative Pathobiology, The Johns Hopkins University, Baltimore, MD, USA.,Department of Radiology and Radiological Science, Express Radiology Research Lab, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Radiology and Radiological Science, Veterinary Clinical Trials Network, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Anesthesiology and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - M Christine Zink
- Department of Molecular and Comparative Pathobiology, The Johns Hopkins University, Baltimore, MD, USA
| | - Cory F Brayton
- Department of Molecular and Comparative Pathobiology, The Johns Hopkins University, Baltimore, MD, USA
| | - Meaghan Morris
- Department of Pathology, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | | | - Danielle R Donahue
- Mouse Imaging Facility, National Institutes of Health, Bethesda, MD, USA
| | - Matthew R Dreher
- Biocompatibles UK Ltd., a BTG International group company, Farnham, Surrey, UK
| | - Dara L Kraitchman
- Department of Molecular and Comparative Pathobiology, The Johns Hopkins University, Baltimore, MD, USA.,Department of Radiology and Radiological Science, Center for Image-Guided Animal Therapy, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Clifford R Weiss
- Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department Biomedical Engineering, The Johns Hopkins Whiting School of Engineering, Baltimore, MD, USA
| |
Collapse
|
35
|
Jafargholi Rangraz E, Tang X, Van Laeken C, Maleux G, Dekervel J, Van Cutsem E, Verslype C, Baete K, Nuyts J, Deroose CM. Quantitative comparison of pre-treatment predictive and post-treatment measured dosimetry for selective internal radiation therapy using cone-beam CT for tumor and liver perfusion territory definition. EJNMMI Res 2020; 10:94. [PMID: 32797332 PMCID: PMC7427681 DOI: 10.1186/s13550-020-00675-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Accepted: 07/17/2020] [Indexed: 11/21/2022] Open
Abstract
Background Selective internal radiation therapy (SIRT) is a promising treatment for unresectable hepatic malignancies. Predictive dose calculation based on a simulation using 99mTc-labeled macro-aggregated albumin (99mTc-MAA) before the treatment is considered as a potential tool for patient-specific treatment planning. Post-treatment dose measurement is mainly performed to confirm the planned absorbed dose to the tumor and non-tumor liver volumes. This study compared the predicted and measured absorbed dose distributions. Methods Thirty-one patients (67 tumors) treated by SIRT with resin microspheres were analyzed. Predicted and delivered absorbed dose was calculated using 99mTc-MAA-SPECT and 90Y-TOF-PET imaging. The voxel-level dose distribution was derived using the local deposition model. Liver perfusion territories and tumors have been delineated on contrast-enhanced CBCT images, which have been acquired during the 99mTc-MAA work-up. Several dose-volume histogram (DVH) parameters together with the mean dose for liver perfusion territories and non-tumoral and tumoral compartments were evaluated. Results A strong correlation between the predicted and measured mean dose for non-tumoral volume was observed (r = 0.937). The ratio of measured and predicted mean dose to this volume has a first, second, and third interquartile range of 0.83, 1.05, and 1.25. The difference between the measured and predicted mean dose did not exceed 11 Gy. The correlation between predicted and measured mean dose to the tumor was moderate (r = 0.623) with a mean difference of − 9.3 Gy. The ratio of measured and predicted tumor mean dose had a median of 1.01 with the first and third interquartile ranges of 0.58 and 1.59, respectively. Our results suggest that 99mTc-MAA-based dosimetry could predict under or over dosing of the non-tumoral liver parenchyma for almost all cases. For more than two thirds of the tumors, a predictive absorbed dose correctly indicated either good tumor dose coverage or under-dosing of the tumor. Conclusion Our results highlight the predictive value of 99mTc-MAA-based dose estimation to predict non-tumor liver irradiation, which can be applied to prescribe an optimized activity aiming at avoiding liver toxicity. Compared to non-tumoral tissue, a poorer agreement between predicted and measured absorbed dose is observed for tumors.
Collapse
Affiliation(s)
- Esmaeel Jafargholi Rangraz
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium.
| | - Xikai Tang
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| | | | - Geert Maleux
- Radiology Section, University Hospitals Leuven, Department of Imaging and Pathology, Leuven, Belgium
| | - Jeroen Dekervel
- Digestive Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Eric Van Cutsem
- Digestive Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Chris Verslype
- Digestive Oncology, University Hospitals Leuven, Leuven, Belgium
| | - Kristof Baete
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| | - Johan Nuyts
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| | - Christophe M Deroose
- Nuclear Medicine, University Hospitals Leuven, Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, Leuven, Belgium
| |
Collapse
|
36
|
Mora-Ramirez E, Santoro L, Cassol E, Ocampo-Ramos JC, Clayton N, Kayal G, Chouaf S, Trauchessec D, Pouget JP, Kotzki PO, Deshayes E, Bardiès M. Comparison of commercial dosimetric software platforms in patients treated with 177 Lu-DOTATATE for peptide receptor radionuclide therapy. Med Phys 2020; 47:4602-4615. [PMID: 32632928 PMCID: PMC7589428 DOI: 10.1002/mp.14375] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 06/21/2020] [Accepted: 06/22/2020] [Indexed: 12/17/2022] Open
Abstract
Purpose The aim of this study was to quantitatively compare five commercial dosimetric software platforms based on the analysis of clinical datasets of patients who benefited from peptide receptor radionuclide therapy (PRRT) with 177Lu‐DOTATATE (LUTATHERA®). Methods The dosimetric analysis was performed on two patients during two cycles of PRRT with 177Lu. Single photon emission computed tomography/computed tomography images were acquired at 4, 24, 72, and 192 h post injection. Reconstructed images were generated using Dosimetry Toolkit® (DTK) from Xeleris™ and HybridRecon‐Oncology version_1.3_Dicom (HROD) from HERMES. Reconstructed images using DTK were analyzed using the same software to calculate time‐integrated activity coefficients (TIAC), and mean absorbed doses were estimated using OLINDA/EXM V1.0 with mass correction. Reconstructed images from HROD were uploaded into PLANET® OncoDose from DOSIsoft, STRATOS from Phillips, Hybrid Dosimetry Module™ from HERMES, and SurePlan™ MRT from MIM. Organ masses, TIACs, and mean absorbed doses were calculated from each application using their recommendations. Results The majority of organ mass estimates varied by <9.5% between all platforms. The highest variability for TIAC results between platforms was seen for the kidneys (28.2%) for the two patients and the two treatment cycles. Relative standard deviations in mean absorbed doses were slightly higher compared with those observed for TIAC, but remained of the same order of magnitude between all platforms. Conclusions When applying a similar processing approach, results obtained were of the same order of magnitude regardless of the platforms used. However, the comparison of the performances of currently available platforms is still difficult as they do not all address the same parts of the dosimetric analysis workflow. In addition, the way in which data are handled in each part of the chain from data acquisition to absorbed doses may be different, which complicates the comparison exercise. Therefore, the dissemination of commercial solutions for absorbed dose calculation calls for the development of tools and standards allowing for the comparison of the performances between dosimetric software platforms.
Collapse
Affiliation(s)
- Erick Mora-Ramirez
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,Escuela de Física - CICANUM, Universidad de Costa Rica, San José, 11501-2060, Costa Rica
| | - Lore Santoro
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Emmanuelle Cassol
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,Département de Médecine Nucléaire, Hôpitaux Toulouse, Toulouse, F-31059, France.,Faculté de Médecine Rangueil, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Juan C Ocampo-Ramos
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Naomi Clayton
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Gunjan Kayal
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol, BE-2400, Belgium
| | - Soufiane Chouaf
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Dorian Trauchessec
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Jean-Pierre Pouget
- Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Pierre-Olivier Kotzki
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Emmanuel Deshayes
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Manuel Bardiès
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| |
Collapse
|
37
|
Siman W, Mawlawi OR, Mourtada F, Kappadath SC. Systematic and random errors of PET‐based
90
Y 3D dose quantification. Med Phys 2020; 47:2441-2449. [DOI: 10.1002/mp.14117] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 01/21/2020] [Accepted: 02/26/2020] [Indexed: 11/10/2022] Open
Affiliation(s)
- W. Siman
- Department of Radiology The University of Colorado School of Medicine Denver CO USA
| | - O. R. Mawlawi
- Department of Imaging Physics The University of Texas MD Anderson Cancer Center Houston TX USA
- The University of Texas Graduate School of Biomedical Sciences at Houston Houston TX USA
| | | | - S. C. Kappadath
- Department of Imaging Physics The University of Texas MD Anderson Cancer Center Houston TX USA
- The University of Texas Graduate School of Biomedical Sciences at Houston Houston TX USA
| |
Collapse
|
38
|
Seo Y, Khalighi MM, Wangerin KA, Deller TW, Wang YH, Jivan S, Kohi MP, Aggarwal R, Flavell RR, Behr SC, Evans MJ. Quantitative and Qualitative Improvement of Low-Count [ 68Ga]Citrate and [ 90Y]Microspheres PET Image Reconstructions Using Block Sequential Regularized Expectation Maximization Algorithm. Mol Imaging Biol 2020; 22:208-216. [PMID: 30993558 PMCID: PMC6800603 DOI: 10.1007/s11307-019-01347-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE There are several important positron emission tomography (PET) imaging scenarios that require imaging with very low photon statistics, for which both quantitative accuracy and visual quality should not be neglected. For example, PET imaging with the low photon statistics is closely related to active efforts to significantly reduce radiation exposure from radiopharmaceuticals. We investigated two examples of low-count PET imaging: (a) imaging [90Y]microsphere radioembolization that suffers the very small positron emission fraction of Y-90's decay processes, and (b) cancer imaging with [68Ga]citrate with uptake time of 3-4 half-lives, necessary for visualizing tumors. In particular, we investigated a type of penalized likelihood reconstruction algorithm, block sequential regularized expectation maximization (BSREM), for improving both image quality and quantitative accuracy of these low-count PET imaging cases. PROCEDURES The NEMA/IEC Body phantom filled with aqueous solution of Y-90 or Ga-68 was scanned to mimic the low-count scenarios of corresponding patient data acquisitions on a time-of-flight (TOF) PET/magnetic resonance imaging system. Contrast recovery, background variation, and signal-to-noise ratio were evaluated in different sets of count densities using both conventional TOF ordered subset expectation (TOF-OSEM) and TOF-BSREM algorithms. The regularization parameter, beta, in BSREM that controls the tradeoff between image noise and resolution was evaluated to find a value for improved confidence in image interpretation. Visual quality assessment of the images obtained from patients administered with [68Ga]citrate (n = 6) was performed. We also made preliminary visual image quality assessment for one patient with [90Y]microspheres. In Y-90 imaging, the effect of 511-keV energy window selection for minimizing the number of random events was also evaluated. RESULTS Quantitatively, phantom images reconstructed with TOF-BSREM showed improved contrast recovery, background variation, and signal-to-noise ratio values over images reconstructed with TOF-OSEM. Both phantom and patient studies of delayed imaging of [68Ga]citrate show that TOF-BSREM with beta = 500 gives the best tradeoff between image noise and image resolution based on visual assessment by the readers. The NEMA-IQ phantom study with [90Y]microspheres shows that the narrow energy window (460-562 keV) recovers activity concentrations in small spheres better than the regular energy window (425-650 keV) with the beta value of 2000 using the TOF-BSREM algorithm. For the images obtained from patients with [68Ga]citrate using TOF-BSREM with beta = 500, the visual analogue scale (VAS) was improved by 17 % and the Likert score was increased by 1 point on average, both in comparison to corresponding scores for images reconstructed using TOF-OSEM. CONCLUSION Our investigation shows that the TOF-BSREM algorithm improves the image quality and quantitative accuracy in low-count PET imaging scenarios. However, the beta value in this algorithm needed to be adjusted for each radiopharmaceutical and counting statistics at the time of scans.
Collapse
Affiliation(s)
- Youngho Seo
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, 94143-0946, USA.
- Department of Radiation Oncology, University of California, San Francisco, CA, USA.
- UC Berkeley - UCSF Graduate Program in Bioengineering, University of California, Berkeley and San Francisco, California, CA, USA.
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
| | - Mohammad Mehdi Khalighi
- GE Healthcare, Waukesha, WI, USA
- Department of Radiology, Stanford University, Stanford, CA, USA
| | | | | | | | - Salma Jivan
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, 94143-0946, USA
| | - Maureen P Kohi
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, 94143-0946, USA
| | - Rahul Aggarwal
- Division of Hematology and Oncology, Department of Medicine, University of California, San Francisco, CA, USA
| | - Robert R Flavell
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, 94143-0946, USA
- Department of Pharmaceutical Chemistry, University of California, San Francisco, CA, USA
| | - Spencer C Behr
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, 94143-0946, USA
| | - Michael J Evans
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, 94143-0946, USA
- Department of Pharmaceutical Chemistry, University of California, San Francisco, CA, USA
| |
Collapse
|
39
|
The number of microspheres in Y90 radioembolization directly affects normal tissue radiation exposure. Eur J Nucl Med Mol Imaging 2019; 47:816-827. [PMID: 31741021 DOI: 10.1007/s00259-019-04588-x] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 10/22/2019] [Indexed: 12/13/2022]
Abstract
PURPOSE In Y90 radioembolization, the number of microspheres infused varies by more than a factor of 20 over the shelf-life of the glass radioembolization device. We investigated the effect of the number of Y90 microspheres on normal liver tissue. METHOD Healthy pigs received lobar radioembolization with glass Y90 microspheres at 4, 8, 12, and 16 days post-calibration, representing a > 20× range in the number of microspheres deposited per milliliter in tissue. Animals were survived for 1-month post-treatment and the livers were explanted and scanned on a micro CT system to fully characterize the microscopic distribution of individual microspheres. A complete 3D microdosimetric evaluation of each liver was performed with a spatially correlated analysis of histopathologic effect. RESULTS Through whole-lobe microscopic identification of each microsphere, a consistent number of microspheres per sphere cluster was found at 4, 8, and 12 days postcalibration, despite an 8-fold increase in total microspheres infused from days 4 to 12. The additional microspheres instead resulted in more clusters formed and, therefore, a more homogeneous microscopic absorbed dose. The increased absorbed-dose homogeneity resulted in a greater volume fraction of the liver receiving a potentially toxic absorbed dose based on radiobiologic models. Histopathologic findings in the animals support a possible increase in normal liver toxicity in later treatments with more spheres (i.e., ≥ day 12) compared to early treatments with less spheres (i.e., ≤ day 8). CONCLUSION The microdosimetric evidence presented supports a recommendation of caution when treating large volumes (e.g., right lobe) using glass 90Y microspheres at more than 8 days post-calibration, i.e., after "2nd week" Monday. The favorable normal tissue microscopic distribution and associated low toxicity of first week therapies may encourage opportunities for dose escalation with glass microspheres and could also be considered for patients with decreased hepatic reserve.
Collapse
|
40
|
|
41
|
Jadoul A, Bernard C, Lovinfosse P, Gérard L, Lilet H, Cornet O, Hustinx R. Comparative dosimetry between 99mTc-MAA SPECT/CT and 90Y PET/CT in primary and metastatic liver tumors. Eur J Nucl Med Mol Imaging 2019; 47:828-837. [PMID: 31388721 DOI: 10.1007/s00259-019-04465-7] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 07/26/2019] [Indexed: 12/22/2022]
Abstract
INTRODUCTION The aim of this study is to determine whether 99mTc-MAA SPECT/CT-based dosimetry could predict the actual absorbed dose in hepatocellular carcinoma (HCC) or liver metastases, treated by glass or resin microspheres. MATERIAL AND METHODS Fifty-seven patients who underwent selective internal radiation therapy (SIRT) were retrospectively included in the study, for a total of 59 treatments. Nineteen HCC were treated by resin microspheres (HCC-SIR), 20 HCC with glass microspheres (HCC-Thera), and 20 liver metastases with resin microspheres (Metastases-SIR). The mean absorbed doses in tumoral liver (Dm) and non-tumoral liver (DmNTL) were determined on the 99mTc-MAA SPECT/CT and the 90Y PET/CT, and compared with each other. RESULTS DmNTL was < 50 Gy in the 3 groups, with a strong correlation in all population, albeit slightly lower in Metastases-SIR than HCC-SIR and HCC-Thera (CCC 0.8, 0.94 and 0.96, respectively). In tumoral liver, Dm was higher in HCC than metastases (159 ± 117 Gy versus 63 ± 31 Gy). 99mTc-MAA SPECT/CT proved to be a better indicator of Dm in HCC compared with metastases, with similar 99mTc-MAA-90Y concordance in resin and glass microspheres (CCC HCC-SIR 0.82, CCC HCC-Thera 0.82, and CCC Metastases-SIR 0.52). CONCLUSION 99mTc-MAA SPECT/CT is a reasonably reliable tool for predicting the dose to the non-tumoral liver in both HCC and metastases, regardless of the type of microspheres. It is also fairly reliable for predicting the tumor dose in HCC, again regardless of the type of spheres, although individual variations are observed.
Collapse
Affiliation(s)
- Alexandre Jadoul
- Division of Nuclear Medicine and Oncological Imaging, University Hospital of Liege, B35 Domaine Universitaire du Sart-Tilman, 4000, Liege, Belgium.
| | - Claire Bernard
- Division of Nuclear Medicine and Oncological Imaging, University Hospital of Liege, B35 Domaine Universitaire du Sart-Tilman, 4000, Liege, Belgium
| | - Pierre Lovinfosse
- Division of Nuclear Medicine and Oncological Imaging, University Hospital of Liege, B35 Domaine Universitaire du Sart-Tilman, 4000, Liege, Belgium
| | - Laurent Gérard
- Division of Radiology, University Hospital of Liege, Liege, Belgium
| | - Henri Lilet
- Division of Nuclear Medicine and Oncological Imaging, University Hospital of Liege, B35 Domaine Universitaire du Sart-Tilman, 4000, Liege, Belgium
| | - Olivier Cornet
- Division of Radiology, University Hospital of Liege, Liege, Belgium
| | - Roland Hustinx
- Division of Nuclear Medicine and Oncological Imaging, University Hospital of Liege, B35 Domaine Universitaire du Sart-Tilman, 4000, Liege, Belgium
| |
Collapse
|
42
|
Dewaraja YK, Devasia T, Kaza RK, Mikell JK, Owen D, Roberson PL, Schipper MJ. Prediction of Tumor Control in 90Y Radioembolization by Logit Models with PET/CT-Based Dose Metrics. J Nucl Med 2019; 61:104-111. [PMID: 31147404 DOI: 10.2967/jnumed.119.226472] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 05/23/2019] [Indexed: 12/17/2022] Open
Abstract
The aim of this work was to develop models for tumor control probability (TCP) in radioembolization with 90Y PET/CT-derived radiobiologic dose metrics. Methods: Patients with primary liver cancer or liver metastases who underwent radioembolization with glass microspheres were imaged with 90Y PET/CT for voxel-level dosimetry to determine lesion absorbed dose (AD) metrics, biological effective dose (BED) metrics, equivalent uniform dose, and equivalent uniform BED for 28 treatments (89 lesions). The lesion dose-shrinkage correlation was assessed on the basis of RECIST and, when available, modified RECIST (mRECIST) at first follow-up. For a subset with mRECIST, logit regression TCP models were fit via maximum likelihood to relate lesion-level binary response to the dose metrics. As an exploratory analysis, the nontumoral liver dose-toxicity relationship was also evaluated. Results: Lesion dose-shrinkage analysis showed that there were no significant differences between model parameters for primary and metastatic subgroups and that correlation coefficients were superior with mRECIST. Therefore, subsequent TCP analysis was performed for the combined group using mRECIST only. The overall lesion-level mRECIST response rate was 57%. The AD and BED metrics yielding 50% TCP were 292 and 441 Gy, respectively. All dose metrics considered for TCP modeling, including mean AD, were significantly associated with the probability of response, with high areas under the curve (0.87-0.90, P < 0.0001) and high sensitivity (>0.75) and specificity (>0.83) calculated using a threshold corresponding to 50% TCP. Because nonuniform AD deposition by microspheres cannot be determined by PET at a microscopic scale, radiosensitivity values extracted here by fitting models to clinical response data were substantially lower than reported for in vitro cell cultures or for external-beam radiotherapy clinical studies. There was no correlation between nontumoral liver AD and toxicity measures. Conclusion: Despite the heterogeneous patient cohort, logistic regression TCP models showed a strong association between various dose metrics and the probability of response. The performance of mean AD was comparable to that of radiobiologic dose metrics that involve more complex calculations. These results demonstrate the importance of considering TCP in treatment planning for radioembolization.
Collapse
Affiliation(s)
- Yuni K Dewaraja
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - Theresa Devasia
- Department of Biostatistics, University of Michigan, Ann Arbor, Michigan; and
| | - Ravi K Kaza
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - Justin K Mikell
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Dawn Owen
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Peter L Roberson
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| | - Matthew J Schipper
- Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan
| |
Collapse
|
43
|
Maughan NM, Garcia-Ramirez J, Arpidone M, Swallen A, Laforest R, Goddu SM, Parikh PJ, Zoberi JE. Validation of post-treatment PET-based dosimetry software for hepatic radioembolization of Yttrium-90 microspheres. Med Phys 2019; 46:2394-2402. [PMID: 30742714 DOI: 10.1002/mp.13444] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2018] [Revised: 01/27/2019] [Accepted: 01/28/2019] [Indexed: 01/06/2023] Open
Abstract
PURPOSE Yttrium-90 (90 Y) microsphere radioembolization enables selective internal radiotherapy for hepatic malignancies. Currently, there is no standard postdelivery imaging and dosimetry of the microsphere distribution to verify treatment. Recent studies have reported utilizing the small positron yield of 90 Y (32 ppm) with positron emission tomography (PET) to perform treatment verification and dosimetry analysis. In this study, we validated a commercial dosimetry software, MIM SurePlan™ LiverY90 (MIM Software Inc., Cleveland, OH), for clinical use. METHODS A MATLAB-based algorithm for 90 Y PET-based dosimetry was developed in-house and validated for the purpose of commissioning the commercial software. The algorithm is based on voxel S values and dosimetry formalism reported in MIRD Pamphlet 17. We validated the in-house algorithm to establish it as the ground truth by comparing results from a digital point phantom and a digital uniform cylinder to manual calculations. Once we validated our in-house MATLAB-based algorithm, we used it to perform acceptance testing and commissioning of the commercial dosimetry software, MIM SurePlan, which uses the same dosimetry formalism. A 0.4 cm/5% gamma test was performed on PET-derived dose maps from each algorithm of uniform digital and nonuniform physical phantoms filled with 90 Y chloride solution. Average dose (Davg ) and minimum dose to 70% (D70 ) of a given volume of interest (VOI) were compared for the digital phantom, the physical phantom, and five patient cases (27 tumor VOIs), representing different clinical scenarios. RESULTS The gamma-pass rates were 97.26% and 97.66% for the digital and physical phantoms, respectively. The differences between Davg and D70 were 0.076% and 0.10% for the digital phantom, respectively, and <5.2% for various VOIs in the physical phantom. In the clinical cases, 96.3% of the VOIs had a difference <5% for Davg , and 88.9% of the VOIs had a difference <5% for D70 . CONCLUSIONS Dose calculation results from MIM SurePlan were found to be in good agreement with our in-house algorithm. This indicates that MIM SurePlan performs as it should and, hence, can be deemed accepted and commissioned for clinical use for post-implant PET-based dosimetry of 90 Y radioembolization.
Collapse
Affiliation(s)
- Nichole M Maughan
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Jose Garcia-Ramirez
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | | | | | - Richard Laforest
- Department of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - S Murty Goddu
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Parag J Parikh
- Department of Radiation Oncology, Henry Ford Hospital, Detroit, MI, 48202, USA
| | - Jacqueline E Zoberi
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| |
Collapse
|
44
|
Siman W, Mikell JK, Mawlawi OR, Mourtada F, Kappadath SC. Dose volume histogram-based optimization of image reconstruction parameters for quantitative 90 Y-PET imaging. Med Phys 2018; 46:229-237. [PMID: 30375655 DOI: 10.1002/mp.13269] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 10/21/2018] [Accepted: 10/22/2018] [Indexed: 12/20/2022] Open
Abstract
PURPOSE 90 Y-microsphere radioembolization or selective internal radiation therapy is increasingly being used as a treatment option for tumors that are not candidates for surgery and external beam radiation therapy. Recently, volumetric 90 Y-dosimetry techniques have been implemented to explore tumor dose-response on the basis of 3D 90 Y-activity distribution from PET imaging. Despite being a theranostic study, the optimization of quantitative 90 Y-PET image reconstruction still uses the mean activity concentration recovery coefficient (RC) as the objective function, which is more relevant to diagnostic and detection tasks than is to dosimetry. The aim of this study was to optimize 90 Y-PET image reconstruction by minimizing errors in volumetric dosimetry via the dose volume histogram (DVH). We propose a joint optimization of the number of equivalent iterations (the product of the iterations and subsets) and the postreconstruction filtration (FWHM) to improve the accuracy of voxel-level 90 Y dosimetry. METHODS A modified NEMA IEC phantom was used to emulate clinically relevant 90 Y-PET imaging conditions through various combinations of acquisition durations, activity concentrations, sphere-to-background ratios, and sphere diameters. PET data were acquired in list mode for 300 min in a single-bed position; we then rebinned the list mode PET data to 60, 45, 30, 15, and 5 min per bed, with 10 different realizations. Errors in the DVH were calculated as root mean square errors (RMSE) of the differences in the image-based DVH and the expected DVH. The new optimization approach was tested in a phantom study, and the results were compared with the more commonly used objective function of the mean activity concentration RC. RESULTS In a wide range of clinically relevant imaging conditions, using 36 equivalent iterations with a 5.2-mm filtration resulted in decreased systematic errors in volumetric 90 Y dosimetry, quantified as image-based DVH, in 90 Y-PET images reconstructed using the ordered subset expectation maximization (OSEM) iterative reconstruction algorithm with time of flight (TOF) and point spread function (PSF) modeling. Our proposed objective function of minimizing errors in DVH, which allows for joint optimization of 90 Y-PET iterations and filtration for volumetric quantification of the 90 Y dose, was shown to be superior to conventional RC-based optimization approaches for image-based absorbed dose quantification. CONCLUSION Our proposed objective function of minimizing errors in DVH, which allows for joint optimization of iterations and filtration to reduce errors in the PET-based volumetric quantification 90 Y dose, is relevant to dosimetry in therapy procedures. The proposed optimization method using DVH as the objective function could be applied to any imaging modality used to assess voxel-level quantitative information.
Collapse
Affiliation(s)
- Wendy Siman
- Department of Radiology, The University of Tennessee Medical Center, Knoxville, TN, USA.,The University of Tennessee Graduate School of Medicine, Knoxville, TN, USA
| | - Justin K Mikell
- Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, MI, USA
| | - Osama R Mawlawi
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.,The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA
| | | | - S Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.,The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA
| |
Collapse
|
45
|
Bastiaannet R, Kappadath SC, Kunnen B, Braat AJAT, Lam MGEH, de Jong HWAM. The physics of radioembolization. EJNMMI Phys 2018; 5:22. [PMID: 30386924 PMCID: PMC6212377 DOI: 10.1186/s40658-018-0221-z] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 06/19/2018] [Indexed: 12/11/2022] Open
Abstract
Radioembolization is an established treatment for chemoresistant and unresectable liver cancers. Currently, treatment planning is often based on semi-empirical methods, which yield acceptable toxicity profiles and have enabled the large-scale application in a palliative setting. However, recently, five large randomized controlled trials using resin microspheres failed to demonstrate a significant improvement in either progression-free survival or overall survival in both hepatocellular carcinoma and metastatic colorectal cancer. One reason for this might be that the activity prescription methods used in these studies are suboptimal for many patients.In this review, the current dosimetric methods and their caveats are evaluated. Furthermore, the current state-of-the-art of image-guided dosimetry and advanced radiobiological modeling is reviewed from a physics' perspective. The current literature is explored for the observation of robust dose-response relationships followed by an overview of recent advancements in quantitative image reconstruction in relation to image-guided dosimetry.This review is concluded with a discussion on areas where further research is necessary in order to arrive at a personalized treatment method that provides optimal tumor control and is clinically feasible.
Collapse
Affiliation(s)
- Remco Bastiaannet
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - S. Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1155 Pressler St, Unit 1352, Houston, TX 77030 USA
| | - Britt Kunnen
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Arthur J. A. T. Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Marnix G. E. H. Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Hugo W. A. M. de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| |
Collapse
|
46
|
Knešaurek K, Tuli A, Kim E, Heiba S, Kostakoglu L. Comparison of PET/CT and PET/MR imaging and dosimetry of yttrium-90 ( 90Y) in patients with unresectable hepatic tumors who have received intra-arterial radioembolization therapy with 90Y microspheres. EJNMMI Phys 2018; 5:23. [PMID: 30159638 PMCID: PMC6115317 DOI: 10.1186/s40658-018-0222-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Accepted: 07/27/2018] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND The aim of our study was to compare 90Y dosimetry obtained from PET/MRI versus PET/CT post-therapy imaging among patients with primary or metastatic hepatic tumors. First, a water-filled Jaszczak phantom containing fillable sphere with 90Y-chloride was acquired on both the PET/CT and PET/MRI systems, in order to check the cross-calibration of the modalities. Following selective internal radiation therapy (SIRT) with 90Y microspheres, 32 patients were imaged on a PET/CT system, immediately followed by a PET/MRI study. Reconstructed images were transferred to a common platform and used to calculate 90Y dosimetry. A Passing-Bablok regression scatter diagram and the Bland and Altman method were used to analyze the difference between the dosimetry values. RESULTS The phantom study showed that both modalities were calibrated with less than 1% error. The mean liver doses for the 32 subjects calculated from PET/CT and PET/MRI were 51.6 ± 24.7 Gy and 46.5 ± 22.7 Gy, respectively, with a mean difference of 5.1 ± 5.0 Gy. The repeatability coefficient was 9.0 (18.5% of the mean). The Spearman rank correlation coefficient was very high, ρ = 0.97. Although the maximum dose to the liver can be significantly different (up to 40%), mean liver doses from each modalities were relatively close, with a difference of 18.5% or less. CONCLUSIONS The two main contributors to the difference in 90Y dosimetry calculations using PET/CT versus PET/MRI can be attributed to the differences in regions of interest (ROIs) and differences attributed to attenuation correction. Due to the superior soft-tissue contrast of MRI, liver contours are usually better seen than in CT images. However, PET/CT provides better quantification of PET images, due to better attenuation correction. In spite of these differences, our results demonstrate that the dosimetry values obtained from PET/MRI and PET/CT in post-therapy 90Y studies were similar.
Collapse
Affiliation(s)
- Karin Knešaurek
- Division of Nuclear Medicine, Department of Radiology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box 1141, New York, NY, 10029, USA.
| | - Abbas Tuli
- Division of Nuclear Medicine, Department of Radiology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box 1141, New York, NY, 10029, USA
| | - Edward Kim
- Division of Interventional Radiology, Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, USA
| | - Sherif Heiba
- Division of Nuclear Medicine, Department of Radiology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box 1141, New York, NY, 10029, USA
| | - Lale Kostakoglu
- Division of Nuclear Medicine, Department of Radiology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box 1141, New York, NY, 10029, USA
| |
Collapse
|
47
|
Feasibility assessment of yttrium-90 liver radioembolization imaging using amplitude-based gated PET/CT. Nucl Med Commun 2018; 39:222-227. [PMID: 29351124 PMCID: PMC5882249 DOI: 10.1097/mnm.0000000000000794] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Purpose The usage of PET/computed tomography (CT) to monitor hepatocellular carcinoma patients following yttrium-90 (90Y) radioembolization has increased. Respiratory motion causes liver movement, which can be corrected using gating techniques at the expense of added noise. This work examines the use of amplitude-based gating on 90Y-PET/CT and its potential impact on diagnostic integrity. Patients and methods Patients were imaged using PET/CT following 90Y radioembolization. A respiratory band was used to collect respiratory cycle data. Patient data were processed as both standard and motion-corrected images. Regions of interest were drawn and compared using three methods. Activity concentrations were calculated and converted into dose estimates using previously determined and published scaling factors. Diagnostic assessments were performed using a binary scale created from published 90Y-PET/CT image interpretation guidelines. Results Estimates of radiation dose were increased (P<0.05) when using amplitude-gating methods with 90Y PET/CT imaging. Motion-corrected images show increased noise, but the diagnostic determination of success, using the Kao criteria, did not change between static and motion-corrected data. Conclusion Amplitude-gated PET/CT following 90Y radioembolization is feasible and may improve 90Y dose estimates while maintaining diagnostic assessment integrity.
Collapse
|
48
|
Potrebko PS, Shridhar R, Biagioli MC, Sensakovic WF, Andl G, Poleszczuk J, Fox TH. SPECT/CT image-based dosimetry for Yttrium-90 radionuclide therapy: Application to treatment response. J Appl Clin Med Phys 2018; 19:435-443. [PMID: 29962026 PMCID: PMC6123162 DOI: 10.1002/acm2.12400] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Revised: 05/17/2018] [Accepted: 05/29/2018] [Indexed: 12/18/2022] Open
Abstract
This work demonstrates the efficacy of voxel‐based 90Y microsphere dosimetry utilizing post‐therapy SPECT/CT imaging and applies it to the prediction of treatment response for the management of patients with hepatocellular carcinoma (HCC). A 90Y microsphere dosimetry navigator (RapidSphere) within a commercial platform (Velocity, Varian Medical Systems) was demonstrated for three microsphere cases that were imaged using optimized bremsstrahlung SPECT/CT. For each case, the 90Y SPECT/CT was registered to follow‐up diagnostic MR/CT using deformable image registration. The voxel‐based dose distribution was computed using the local deposition method with known injected activity. The system allowed the visualization of the isodose distributions on any of the registered image datasets and the calculation of dose‐volume histograms (DVHs). The dosimetric analysis illustrated high local doses that are characteristic of blood‐flow directed brachytherapy. In the first case, the HCC mass demonstrated a complete response to treatment indicated by a necrotic region in follow‐up MR imaging. This result was dosimetrically predicted since the gross tumor volume (GTV) was well covered by the prescription isodose volume (V150 Gy = 85%). The second case illustrated a partial response to treatment which was characterized by incomplete necrosis of an HCC mass and a remaining area of solid enhancement in follow‐up MR imaging. This result was predicted by dosimetric analysis because the GTV demonstrated incomplete coverage by the prescription isodose volume (V470 Gy = 18%). The third case demonstrated extrahepatic activity. The dosimetry indicated that the prescription (125 Gy) isodose region extended outside of the liver into the duodenum (178 Gy maximum dose). This was predictive of toxicity as the patient later developed a duodenal ulcer. The ability to predict outcomes and complications using deformable image registration, calculated isodose distributions, and DVHs, points to the clinical utility of patient‐specific dose calculations for 90Y radioembolization treatment planning.
Collapse
Affiliation(s)
- Peter S Potrebko
- College of Medicine, University of Central Florida, Orlando, FL, USA.,Department of Physics, University of Central Florida, Orlando, FL, USA.,Department of Radiation Oncology, Florida Hospital, Orlando, FL, USA
| | - Ravi Shridhar
- Department of Radiation Oncology, Florida Hospital, Orlando, FL, USA
| | | | - William F Sensakovic
- College of Medicine, University of Central Florida, Orlando, FL, USA.,Department of Radiology, Florida Hospital, Orlando, FL, USA
| | | | - Jan Poleszczuk
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
| | | |
Collapse
|
49
|
Hepatic selective internal radiation therapy: how well does pretreatment 99mTc-macroaggregated albumin activity distribution and quantification agree with post-therapy bremsstrahlung imaging? Nucl Med Commun 2018; 39:809-817. [PMID: 29879091 DOI: 10.1097/mnm.0000000000000872] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIM The aim of this study was to examine the agreement of pretreatment Tc-macroaggregated albumin imaging performed for selective internal radiation therapy (SIRT) workup with Y percentage lung shunt (PLS) and regional hepatic distribution in subsequent post-therapy bremsstrahlung imaging. PATIENTS AND METHODS Planar images were used to calculate PLS. The significant Y bremsstrahlung scatter required background correction. Results using both Y lung background regions of interest (ROI) reported in previous studies and extended ROIs (reflecting lung background variation) were compared with Tc-MAA PLS. Lesion and healthy liver volumes were outlined on diagnostic computed tomography scans and registered to Tc-MAA and Y single-photon emission computed tomography/computed tomographydata. Single-photon emission computed tomography voxel values were normalized to injected Y activity. Volume mean activities were calculated, and converted into the mean absorbed dose. Agreement was quantified using Bland-Altman analysis. RESULTS PLS: The bias using previous studies' lung background ROIs was -10.71%, with a 95% confidence interval (CI) of -18.79 to -2.64%. The extended ROI yielded a bias of 0.77% (95% CI: -2.23 to 3.70%). Liver: The healthy liver bias was 0.01 MBq/ml (0.17 Gy), with a -0.05 to 0.06 MBq/ml (95% CI:0.80 -1.93 Gy). The lesion mean activity/ml bias was -0.02 MBq/ml (3.71 Gy), with a -0.81 to 0.76 MBq/ml (95% CI: -35.49 to 28.07 Gy). CONCLUSIONS The PLS agreement was sensitive to the Y lung background correction ROI, potentially explaining a previously published controversy. The mean activity and absorbed dose agreement for the metastatic lesions was poorer than the healthy liver volumes studied here.
Collapse
|
50
|
A Woman with Black Beads in Her Stomach: Severe Gastric Ulceration Caused by Yttrium-90 Radioembolization. Case Rep Med 2018; 2018:1413724. [PMID: 29849654 PMCID: PMC5925165 DOI: 10.1155/2018/1413724] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 02/12/2018] [Accepted: 03/01/2018] [Indexed: 12/25/2022] Open
Abstract
Radioembolization (RE) is a selective internal radiation therapy (SIRT) delivering targeted, high-dose, intra-arterial radiation directly to the vascular supply of liver tumors. Complications can occur due to aberrant deposition or migration of radiation microspheres into nontarget locations, including normal hepatic parenchyma, lungs, pancreas, and upper gastrointestinal (UGI) tract. We report a case of gastric ulcers due to yttrium-90 (90Y) seed migration to the stomach to alert clinicians to this rare cause of gastric injury. A 57-year-old woman with stage IV breast cancer with liver and lung metastases presented to the hospital with 2 months of worsening nausea and vomiting. Two months prior, she had received SIRT with 90Y microspheres without complications. Upper GI endoscopy showed diffuse gastritis and extensive antral ulceration. Biopsies revealed black, spherical foreign bodies, consistent with 90Y microspheres, documenting radiation injury. Radiation-induced UGI ulceration is caused by direct radiation injury from beta-radiation. Delay in diagnosis may be due to the nonspecificity of symptoms and temporal delay of symptom onset from SIRT, which was 2 months in our patient. Also, complaints may be attributed erroneously to adjuvant chemotherapy or widespread metastatic disease. Clinicians must consider radiation-associated toxicity in any SIRT-treated patient developing abdominal symptoms.
Collapse
|