1
|
Sotiropoulos JX, Oei JL, Schmölzer GM, Libesman S, Hunter KE, Williams JG, Webster AC, Vento M, Kapadia V, Rabi Y, Dekker J, Vermeulen MJ, Sundaram V, Kumar P, Kaban RK, Rohsiswatmo R, Saugstad OD, Seidler AL. Initial Oxygen Concentration for the Resuscitation of Infants Born at Less Than 32 Weeks' Gestation: A Systematic Review and Individual Participant Data Network Meta-Analysis. JAMA Pediatr 2024; 178:774-783. [PMID: 38913382 PMCID: PMC11197034 DOI: 10.1001/jamapediatrics.2024.1848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 04/03/2024] [Indexed: 06/25/2024]
Abstract
Importance Resuscitation with lower fractional inspired oxygen (FiO2) reduces mortality in term and near-term infants but the impact of this practice on very preterm infants is unclear. Objective To evaluate the relative effectiveness of initial FiO2 on reducing mortality, severe morbidities, and oxygen saturations (SpO2) in preterm infants born at less than 32 weeks' gestation using network meta-analysis (NMA) of individual participant data (IPD). Data Sources MEDLINE, Embase, CENTRAL, CINAHL, ClinicalTrials.gov, and WHO ICTRP from 1980 to October 10, 2023. Study Selection Eligible studies were randomized clinical trials enrolling infants born at less than 32 weeks' gestation comparing at least 2 initial oxygen concentrations for delivery room resuscitation, defined as either low (≤0.3), intermediate (0.5-0.65), or high (≥0.90) FiO2. Data Extraction and Synthesis Investigators from eligible studies were invited to provide IPD. Data were processed and checked for quality and integrity. One-stage contrast-based bayesian IPD-NMA was performed with noninformative priors and random effects and adjusted for key covariates. Main Outcomes and Measures The primary outcome was all-cause mortality at hospital discharge. Secondary outcomes were morbidities of prematurity and SpO2 at 5 minutes. Results IPD were provided for 1055 infants from 12 of the 13 eligible studies (2005-2019). Resuscitation with high (≥0.90) initial FiO2 was associated with significantly reduced mortality compared to low (≤0.3) (odds ratio [OR], 0.45; 95% credible interval [CrI], 0.23-0.86; low certainty) and intermediate (0.5-0.65) FiO2 (OR, 0.34; 95% CrI, 0.11-0.99; very low certainty). High initial FiO2 had a 97% probability of ranking first to reduce mortality. The effects on other morbidities were inconclusive. Conclusions and Relevance High initial FiO2 (≥0.90) may be associated with reduced mortality in preterm infants born at less than 32 weeks' gestation compared to low initial FiO2 (low certainty). High initial FiO2 is possibly associated with reduced mortality compared to intermediate initial FiO2 (very low certainty) but more evidence is required.
Collapse
Affiliation(s)
- James X. Sotiropoulos
- National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
- School of Women’s and Children’s Health, Faculty of Medicine and Health, University of New South Wales, Kensington, New South Wales, Australia
- Department of Newborn Care, the Royal Hospital for Women, Randwick, New South Wales, Australia
| | - Ju Lee Oei
- School of Women’s and Children’s Health, Faculty of Medicine and Health, University of New South Wales, Kensington, New South Wales, Australia
- Department of Newborn Care, the Royal Hospital for Women, Randwick, New South Wales, Australia
| | - Georg M. Schmölzer
- Department of Pediatrics, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
- Centre for the Studies of Asphyxia and Resuscitation, Neonatology, Royal Alexandra Hospital, Edmonton, Alberta, Canada
| | - Sol Libesman
- National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
| | - Kylie E. Hunter
- National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
| | - Jonathan G. Williams
- National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
| | - Angela C. Webster
- National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
| | - Maximo Vento
- University and Polytechnic Hospital La Fe, Valencia, Spain
- Health Research Institute La Fe, Valencia, Spain
| | - Vishal Kapadia
- Department of Pediatrics, University of Texas Southwestern Medical Center, Dallas
| | - Yacov Rabi
- Department of Pediatrics, University of Calgary, Alberta Children’s Hospital Research Institute, Calgary, Alberta, Canada
| | - Janneke Dekker
- Willem-Alexander Children’s Hospital, Department of Pediatrics, Division of Neonatology, Leiden University Medical Center, Leiden, the Netherlands
| | - Marijn J. Vermeulen
- Department of Neonatal and Pediatric Intensive Care, Division of Neonatology, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Venkataseshan Sundaram
- Division of Neonatology, Department of Pediatrics, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Praveen Kumar
- Division of Neonatology, Department of Pediatrics, Postgraduate Institute of Medical Education and Research, Chandigarh, India
| | - Risma K. Kaban
- Department of Child Health, University of Indonesia Medical School/Dr Cipto Mangunkusumo Hospital, Jakarta, Indonesia
| | - Rinawati Rohsiswatmo
- Department of Child Health, University of Indonesia Medical School/Dr Cipto Mangunkusumo Hospital, Jakarta, Indonesia
| | - Ola D. Saugstad
- Department of Pediatric Research, University of Oslo, Oslo, Norway
- Ann and Robert H. Lurie Children’s Hospital of Chicago, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Anna Lene Seidler
- National Health and Medical Research Council Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia
| |
Collapse
|
2
|
Cramer SJE, Dekker J, Croughan MK, Lee KL, Crossley KJ, McGillick EV, Martherus T, Thio M, Wallace MJ, Kitchen MJ, Hooper SB, Te Pas AB. The effect of vibrotactile stimulation on hypoxia-induced irregular breathing and apnea in preterm rabbits. Pediatr Res 2024; 96:325-331. [PMID: 38356025 DOI: 10.1038/s41390-024-03061-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 12/22/2023] [Accepted: 12/29/2023] [Indexed: 02/16/2024]
Abstract
BACKGROUND Manual tactile stimulation is used to counteract apnea in preterm infants, but it is unknown when this intervention should be applied. We compared an anticipatory to a reactive approach using vibrotactile stimulation to prevent hypoxia induced apneas. METHODS Preterm rabbit kittens were prematurely delivered and randomized to either group. All kittens breathed spontaneously with a positive airway pressure of 8 cmH2O while they were imaged using phase contrast X-ray. Irregular breathing (IB) was induced using gradual hypoxia. The anticipatory group received stimulation at the onset of IB and the reactive group if IB transitioned into apnea. Breathing rate (BR), heart rate (HR) and functional residual capacity (FRC) were compared. RESULTS Anticipatory stimulation significantly reduced apnea incidence and maximum inter-breath intervals and increased BR following IB, compared to reactive stimulation. Recovery in BR but not HR was more likely with anticipatory stimulation, although both BR and HR were significantly higher at 120 s after stimulation onset. FRC values and variability were not different. CONCLUSIONS Anticipated vibrotactile stimulation is more effective in preventing apnea and enhancing breathing when compared to reactive stimulation in preterm rabbits. Stimulation timing is likely to be a key factor in reducing the incidence and duration of apnea. IMPACT Anticipated vibrotactile stimulation can prevent apnea and stimulate breathing effort in preterm rabbits. Anticipated vibrotactile stimulation increases the likelihood of breathing rate recovery following hypoxia induced irregular breathing, when compared to reactive stimulation. Automated stimulation in combination with predictive algorithms may improve the treatment of apnea in preterm infants.
Collapse
Affiliation(s)
- Sophie J E Cramer
- Willem-Alexander Children's Hospital, Department of Pediatrics, Division of Neonatology, Leiden University Medical Center, Leiden, the Netherlands.
| | - Janneke Dekker
- Willem-Alexander Children's Hospital, Department of Pediatrics, Division of Neonatology, Leiden University Medical Center, Leiden, the Netherlands
| | - Michelle K Croughan
- School of Physics and Astronomy, Monash University, Melbourne, VIC, Australia
| | - Katie L Lee
- School of Physics and Astronomy, Monash University, Melbourne, VIC, Australia
- School of Earth and Environmental Science, University of Queensland, Brisbane, QLD, Australia
| | - Kelly J Crossley
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynecology, Monash University, Melbourne, VIC, Australia
| | - Erin V McGillick
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynecology, Monash University, Melbourne, VIC, Australia
| | - Tessa Martherus
- Willem-Alexander Children's Hospital, Department of Pediatrics, Division of Neonatology, Leiden University Medical Center, Leiden, the Netherlands
| | - Martha Thio
- Women's Newborn Research Centre, The Royal Women's Hospital, Melbourne, VIC, Australia
- Centre of Research Excellence in Newborn Medicine, Murdoch Children's Research Institute, Melbourne, VIC, Australia
- Department of Obstetrics and Gynecology, University of Melbourne, Melbourne, VIC, Australia
| | - Megan J Wallace
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynecology, Monash University, Melbourne, VIC, Australia
| | - Marcus J Kitchen
- School of Physics and Astronomy, Monash University, Melbourne, VIC, Australia
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
| | - Stuart B Hooper
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynecology, Monash University, Melbourne, VIC, Australia
| | - Arjan B Te Pas
- Willem-Alexander Children's Hospital, Department of Pediatrics, Division of Neonatology, Leiden University Medical Center, Leiden, the Netherlands
| |
Collapse
|
3
|
Sotiropoulos JX, Oei JL. The role of oxygen in the development and treatment of bronchopulmonary dysplasia. Semin Perinatol 2023; 47:151814. [PMID: 37783577 DOI: 10.1016/j.semperi.2023.151814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Oxygen (O2) is crucial for both the development and treatment of one of the most important consequences of prematurity: bronchopulmonary dysplasia (BPD). In fetal life, the hypoxic environment is important for alveolar development and maturation. After birth, O2 becomes a double-edged sword. While O2 is needed to prevent hypoxia, it also causes oxidative stress leading to a plethora of morbidities, including retinopathy and BPD. The advent of continuous O2 monitoring with pulse oximeters has allowed clinicians to recognize the narrow therapeutic margins of oxygenation for the preterm infant, but more knowledge is needed to understand what these ranges are at different stages of the preterm infant's life, including at birth, in the neonatal intensive care unit and after hospital discharge. Future research, especially in innovative technologies such as automated O2 control and remote oximetry, will improve the understanding and treatment of the O2 needs of infants with BPD.
Collapse
Affiliation(s)
- J X Sotiropoulos
- School of Women's and Children's Health, Faculty of Medicine, University of New South Wales, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, New South Wales, Australia; NHMRC Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Australia
| | - J L Oei
- School of Women's and Children's Health, Faculty of Medicine, University of New South Wales, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, New South Wales, Australia; NHMRC Clinical Trials Centre, Faculty of Medicine and Health, University of Sydney, Australia.
| |
Collapse
|
4
|
Escrig-Fernández R, Zeballos-Sarrato G, Gormaz-Moreno M, Avila-Alvarez A, Toledo-Parreño JD, Vento M. The Respiratory Management of the Extreme Preterm in the Delivery Room. CHILDREN (BASEL, SWITZERLAND) 2023; 10:351. [PMID: 36832480 PMCID: PMC9955623 DOI: 10.3390/children10020351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 02/03/2023] [Accepted: 02/06/2023] [Indexed: 02/12/2023]
Abstract
The fetal-to-neonatal transition poses an extraordinary challenge for extremely low birth weight (ELBW) infants, and postnatal stabilization in the delivery room (DR) remains challenging. The initiation of air respiration and the establishment of a functional residual capacity are essential and often require ventilatory support and oxygen supplementation. In recent years, there has been a tendency towards the soft-landing strategy and, subsequently, non-invasive positive pressure ventilation has been generally recommended by international guidelines as the first option for stabilizing ELBW in the delivery room. On the other hand, supplementation with oxygen is another cornerstone of the postnatal stabilization of ELBW infants. To date, the conundrum concerning the optimal initial inspired fraction of oxygen, target saturations in the first golden minutes, and oxygen titration to achieve desired stability saturation and heart rate values has not yet been solved. Moreover, the retardation of cord clamping together with the initiation of ventilation with the patent cord (physiologic-based cord clamping) have added additional complexity to this puzzle. In the present review, we critically address these relevant topics related to fetal-to-neonatal transitional respiratory physiology, ventilatory stabilization, and oxygenation of ELBW infants in the delivery room based on current evidence and the most recent guidelines for newborn stabilization.
Collapse
Affiliation(s)
- Raquel Escrig-Fernández
- Department of Neonatology, Hospital Universitari i Politècnic La Fe, 106 Fernando Abril Martorell Avenue, 46026 Valencia, Spain
| | | | - María Gormaz-Moreno
- Department of Neonatology, Hospital Universitari i Politècnic La Fe, 106 Fernando Abril Martorell Avenue, 46026 Valencia, Spain
| | - Alejandro Avila-Alvarez
- Division of Neonatology, Pediatric Department, Complexo Hospitalario Universitario de A Coruña (CHUAC), Sergas, 15006 A Coruña, Spain
| | - Juan Diego Toledo-Parreño
- Department of Neonatology, Hospital Universitari i Politècnic La Fe, 106 Fernando Abril Martorell Avenue, 46026 Valencia, Spain
| | - Máximo Vento
- Department of Neonatology, Hospital Universitari i Politècnic La Fe, 106 Fernando Abril Martorell Avenue, 46026 Valencia, Spain
| |
Collapse
|
5
|
Pemberton C, Howarth C. Resuscitation Council UK: review of updated 2021 neonatal life support guideline. Arch Dis Child Educ Pract Ed 2023; 108:38-42. [PMID: 35383127 DOI: 10.1136/archdischild-2021-323277] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Accepted: 03/09/2022] [Indexed: 01/26/2023]
Affiliation(s)
- Chloe Pemberton
- NICU, Homerton University Hospital NHS Foundation Trust, London, UK
| | - Claire Howarth
- NICU, Homerton University Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
6
|
Sotiropoulos JX, Vento M, Saugstad OD, Oei JL. The quest for optimum oxygenation during newborn delivery room resuscitation: Is it the baby or is it us? Semin Perinatol 2022; 46:151622. [PMID: 35725654 DOI: 10.1016/j.semperi.2022.151622] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Achieving "normal oxygenation" in sick newborn infants requiring resuscitation is one of the most difficult and incompletely informed practices in neonatal care. Suboptimal oxygenation, whether too little or too much, has profound repercussions, including death. In the last two decades, clinicians have lost equipoise for the use of higher oxygen strategies due to concerns of hyperoxia but emerging evidence suggests that lower oxygen strategies may also be as detrimental, especially in infants with pulmonary pathologies such as those born at the cusp of viability. Practice at the coalface using rapidly evolving recommendations has also uncovered continuing complexities in the quest to achieve optimum oxygenation during the first critical minutes of life. There are adjustable factors, such as the practical impediments to acquiring knowledge, equipment and expertise as well as unadjustable factors, such as inherent infant pathology, that necessitates agile clinical manipulation to "first do no harm". This review will address the deficiencies in knowledge that currently impede our quest to determine the best and safest means to deliver oxygen to sick infants during the first critical minutes of life and suggest practical solutions for current practice while awaiting definitive evidence from large scale, well defined, randomized controlled studies.
Collapse
Affiliation(s)
- James Xavier Sotiropoulos
- Faculty of Medicine, School of Women's and Children's Health, University of New South Wales, Kensington, NSW, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, NSW, Australia
| | - Maximo Vento
- University and Polytechnic Hospital La Fe, Valencia, Spain; Health Research Institute La Fe, Valencia, Spain
| | - Ola D Saugstad
- Northwestern University, Chicago, USA; University of Oslo, Oslo, Norway
| | - Ju Lee Oei
- Faculty of Medicine, School of Women's and Children's Health, University of New South Wales, Kensington, NSW, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, NSW, Australia.
| |
Collapse
|
7
|
Technology in the delivery room supporting the neonatal healthcare provider's task. Semin Fetal Neonatal Med 2022; 27:101333. [PMID: 35400603 DOI: 10.1016/j.siny.2022.101333] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Very preterm infants are a unique and highly vulnerable group of patients that have a narrow physiological margin within which interventions are safe and effective. The increased understanding of the foetal to neonatal transition marks the intricacy of the rapid and major physiological changes that take place, making delivery room stabilisation and resuscitation an increasingly complex and sophisticated activity for caregivers to perform. While modern, automated technologies are progressively implemented in the neonatal intensive care unit (NICU) to enhance the caregivers in providing the right care for these patients, the technology in the delivery room still lags far behind. Diligent translation of well-known and promising technological solutions from the NICU to the delivery room will allow for better support of the caregivers in performing their tasks. In this review we will discuss the current technology used for stabilisation of preterm infants in the delivery room and how this could be optimised in order to further improve care and outcomes of preterm infants in the near future.
Collapse
|
8
|
Higher CPAP levels improve functional residual capacity at birth in preterm rabbits. Pediatr Res 2022; 91:1686-1694. [PMID: 34294868 DOI: 10.1038/s41390-021-01647-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 06/03/2021] [Accepted: 06/17/2021] [Indexed: 11/08/2022]
Abstract
BACKGROUND Preterm infants are commonly supported with 4-8 cm H2O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC). METHODS Preterm rabbits delivered at 29/32 days (~26-28 weeks human) gestation received 0, 5, 8, 12, 15 cm H2O of CPAP or variable CPAP of 15 to 5 or 15 to 8 cm H2O (decreasing ~2 cm H2O/min) for up to 10 min after birth. RESULTS FRC was lower in the 0 (6.8 (1.0-11.2) mL/kg) and 5 (10.1 (1.1-16.8) mL/kg) compared to the 15 (18.8 (10.9-22.4) mL/kg) cm H2O groups (p = 0.003). Fewer kittens achieved FRC > 15 mL/kg in the 0 (20%), compared to 8 (36%), 12 (60%) and 15 (73%) cm H2O groups (p = 0.008). While breathing rates were not different (p = 0.096), apnoea tended to occur more often with CPAP < 8 cm H2O (p = 0.185). CPAP belly and lung bulging rates were similar whereas pneumothoraces were rare. Lowering CPAP from 15 to 5, but not 15 to 8 cm H2O, decreased FRC and breathing rates. CONCLUSION In all, 15 cm H2O of CPAP improved lung aeration and reduced apnoea, but did not increase the risk of lung over-expansion, pneumothorax or CPAP belly immediately after birth. FRC and breathing rates were maintained when CPAP was decreased to 8 cm H2O. IMPACT Although preterm infants are commonly supported with 4-8 cm H2O CPAP at birth, preclinical studies have shown that higher PEEP levels improve lung aeration. In this study, CPAP levels of 15 cm H2O improved lung aeration and reduced apnoea in preterm rabbit kittens immediately after birth. In all, 15 cm H2O CPAP did not increase the risk of lung over-expansion (indicated by bulging between the ribs), pneumothorax, or CPAP belly. These results can be used when designing future studies on CPAP strategies for preterm infants in the delivery room.
Collapse
|
9
|
Kaufmann M, Mense L, Springer L, Dekker J. Tactile stimulation in the delivery room: past, present, future. A systematic review. Pediatr Res 2022:10.1038/s41390-022-01945-9. [PMID: 35124690 DOI: 10.1038/s41390-022-01945-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/05/2021] [Accepted: 12/14/2021] [Indexed: 11/08/2022]
Abstract
In current resuscitation guidelines, tactile stimulation is recommended for infants with insufficient respiratory efforts after birth. No recommendations are made regarding duration, onset, and method of stimulation. Neither is mentioned how tactile stimulation should be applied in relation to the gestational age. The aim was to review the physiological mechanisms of respiratory drive after birth and to identify and structure the current evidence on tactile stimulation during neonatal resuscitation. A systematic review of available data was performed using PubMed, covering the literature up to April 2021. Two independent investigators screened the extracted references and assessed their methodological quality. Six studies were included. Tactile stimulation management, including the onset of stimulation, overall duration, and methods as well as the effect on vital parameters was analyzed and systematically presented. Tactile stimulation varies widely between, as well as within different centers and no consensus exists which stimulation method is most effective. Some evidence shows that repetitive stimulation within the first minutes of resuscitation improves oxygenation. Further studies are warranted to optimize strategies to support spontaneous breathing after birth, assessing the effect of stimulating various body parts respectively within different gestational age groups.
Collapse
Affiliation(s)
- M Kaufmann
- Division of Neonatology and Paediatric Intensive Care Medicine, Department of Paediatrics, Medical Faculty, TU Dresden, Dresden, Germany.
| | - L Mense
- Division of Neonatology and Paediatric Intensive Care Medicine, Department of Paediatrics, Medical Faculty, TU Dresden, Dresden, Germany
- Saxony Center for Feto-Neonatal Health, Medical Faculty, TU Dresden, Dresden, Germany
| | - L Springer
- Division of Neonatology, Department of Paediatrics, University Children's Hospital Tuebingen, Tuebingen, Germany
| | - J Dekker
- Division of Neonatology, Department of Paediatrics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
10
|
Lara-Cantón I, Badurdeen S, Dekker J, Davis P, Roberts C, Te Pas A, Vento M. Oxygen saturation and heart rate in healthy term and late preterm infants with delayed cord clamping. Pediatr Res 2022:10.1038/s41390-021-01805-y. [PMID: 34997223 DOI: 10.1038/s41390-021-01805-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 10/03/2021] [Accepted: 10/06/2021] [Indexed: 01/10/2023]
Abstract
Blood oxygen in the fetus is substantially lower than in the newborn infant. In the minutes after birth, arterial oxygen saturation rises from around 50-60% to 90-95%. Initial respiratory efforts generate negative trans-thoracic pressures that drive liquid from the airways into the lung interstitium facilitating lung aeration, blood oxygenation, and pulmonary artery vasodilatation. Consequently, intra- (foramen ovale) and extra-cardiac (ductus arteriosus) shunting changes and the sequential circulation switches to a parallel pulmonary and systemic circulation. Delaying cord clamping preserves blood flow through the ascending vena cava, thus increasing right and left ventricular preload. Recently published reference ranges have suggested that delayed cord clamping positively influenced the fetal-to-neonatal transition. Oxygen saturation in babies with delayed cord clamping plateaus significantly earlier to values of 85-90% than in babies with immediate cord clamping. Delayed cord clamping may also contribute to fewer episodes of brady-or-tachycardia in the first minutes after birth, but data from randomized trials are awaited. IMPACT: Delaying cord clamping during fetal to neonatal transition contributes to a significantly earlier plateauing of oxygen saturation and fewer episodes of brady-and/or-tachycardia in the first minutes after birth. We provide updated information regarding the changes in SpO2 and HR during postnatal adaptation of term and late preterm infants receiving delayed compared with immediate cord clamping. Nomograms in newborn infants with delayed cord clamping will provide valuable reference ranges to establish target SpO2 and HR in the first minutes after birth.
Collapse
Affiliation(s)
- Inmaculada Lara-Cantón
- Neonatal Research Group, Health Research Institute and University and Polytechnic Hospital La Fe, Valencia, Spain
| | - Shiraz Badurdeen
- Newborn Research Center and Neonatal Services, The Royal Women´s Hospital, Melbourne, VIC, Australia
| | - Janneke Dekker
- Division of Neonatology, Department of Paediatrics, Leiden University Medical Centre, Leiden, The Netherlands
| | - Peter Davis
- Newborn Research Center and Neonatal Services, The Royal Women´s Hospital, Melbourne, VIC, Australia
| | - Calum Roberts
- Department of Paediatrics, Monash University, Clayton, VIC, Australia
| | - Arjan Te Pas
- Division of Neonatology, Department of Paediatrics, Leiden University Medical Centre, Leiden, The Netherlands
| | - Máximo Vento
- Neonatal Research Group, Health Research Institute and University and Polytechnic Hospital La Fe, Valencia, Spain.
| |
Collapse
|
11
|
Mangat A, Bruckner M, Schmölzer GM. Face mask versus nasal prong or nasopharyngeal tube for neonatal resuscitation in the delivery room: a systematic review and meta-analysis. Arch Dis Child Fetal Neonatal Ed 2021; 106:561-567. [PMID: 33504574 DOI: 10.1136/archdischild-2020-319460] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 12/17/2020] [Accepted: 01/10/2021] [Indexed: 11/04/2022]
Abstract
IMPORTANCE The current neonatal resuscitation guidelines recommend positive pressure ventilation via face mask or nasal prongs at birth. Using a nasal interface may have the potential to improve outcomes for newborn infants. OBJECTIVE To determine whether nasal prong/nasopharyngeal tube versus face mask during positive pressure ventilation of infants born <37 weeks' gestation in the delivery room reduces in-hospital mortality and morbidity. DATA SOURCES MEDLINE (through PubMed), Google Scholar and EMBASE, Clinical Trials.gov and the Cochrane Central Register of Controlled Trials through August 2019. STUDY SELECTION Randomised controlled trials comparing nasal prong/nasopharyngeal tube versus face mask during positive pressure ventilation of infants born <37 weeks' gestation in the delivery room. DATA ANALYSIS Risk of bias was assessed using the Covidence Collaboration Tool, results were pooled into a meta-analysis using a random effects model. MAIN OUTCOME In-hospital mortality. RESULTS Five RCTs enrolling 873 infants were combined into a meta-analysis. There was no statistical difference in in-hospital mortality (risk ratio (RR 0.98, 95% CI 0.63 to 1.52, p=0.92, I2=11%), rate of chest compressions in the delivery room (RR 0.37, 95% CI 0.10 to 1.33, p=0.13, I2=28%), rate of intraventricular haemorrhage (RR 1.54, 95% CI 0.88 to 2.70, p=0.13, I2=0%) or delivery room intubations in infants ventilated with a nasal prong/tube (RR 0.63, 95% CI 0.39,1.02, p=0.06, I2=52%). CONCLUSION In infants born <37 weeks' gestation, in-hospital mortality and morbidity were similar following positive pressure ventilation during initial stabilisation with a nasal prong/tube or a face mask.
Collapse
Affiliation(s)
- Avneet Mangat
- Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada
| | - Marlies Bruckner
- Department of Pediatrics and Adolescent Medicine, Medical University of Graz, Graz, Steiermark, Austria
| | - Georg M Schmölzer
- Department of Pediatrics and Adolescent Medicine, Medical University of Graz, Graz, Steiermark, Austria .,Neonatology, University of Alberta, Edmonton, Alberta, Canada.,Department of Pediatrics and Adolescent Medicine, Medical University Graz, Graz, Steiermark, Austria
| |
Collapse
|
12
|
Gottimukkala SB, Sotiropoulos JX, Lorente-Pozo S, Monti Sharma A, Vento M, Saugstad OD, Oei JL. Oxygen saturation (SpO2) targeting for newborn infants at delivery: Are we reaching for an impossible unknown? Semin Fetal Neonatal Med 2021; 26:101220. [PMID: 33674253 DOI: 10.1016/j.siny.2021.101220] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
For more than 200 years, pure oxygen was given ad libitum to newborn infants requiring resuscitation. Due to oxidative stress and injury concerns, a paradigm shift towards using "less" oxygen, including air (21% oxygen) instead of pure (100%) oxygen, occurred about twenty years ago. A decade later, clinicians were advised to adjust fractional inspired oxygen (FiO2) to target oxygen saturations (SpO2) that were derived from spontaneously breathing, healthy, mature infants. Whether these recommendations are achievable, beneficial, harmful or redundant is uncertain. The underlying pathology leading to resuscitation varies between infants and may considerably alter an infant's response to supplemental oxygen. In this review, we summarize available evidence for the use of SpO2 monitoring at delivery for newborn infants, elucidate existing knowledge and service gaps, and suggest future research recommendations that will lead to the safest clinical strategies for this standard and important practice.
Collapse
Affiliation(s)
- Sasi Bhushan Gottimukkala
- School of Women's and Children's Health, Faculty of Medicine, University of New South Wales, Kensington, NSW, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, NSW, Australia
| | | | | | | | | | | | - Ju Lee Oei
- School of Women's and Children's Health, Faculty of Medicine, University of New South Wales, Kensington, NSW, Australia; Department of Newborn Care, The Royal Hospital for Women, Randwick, NSW, Australia.
| |
Collapse
|
13
|
Morrison JL, Ayonrinde OT, Care AS, Clarke GD, Darby JRT, David AL, Dean JM, Hooper SB, Kitchen MJ, Macgowan CK, Melbourne A, McGillick EV, McKenzie CA, Michael N, Mohammed N, Sadananthan SA, Schrauben E, Regnault TRH, Velan SS. Seeing the fetus from a DOHaD perspective: discussion paper from the advanced imaging techniques of DOHaD applications workshop held at the 2019 DOHaD World Congress. J Dev Orig Health Dis 2021; 12:153-167. [PMID: 32955011 DOI: 10.1017/s2040174420000884] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Advanced imaging techniques are enhancing research capacity focussed on the developmental origins of adult health and disease (DOHaD) hypothesis, and consequently increasing awareness of future health risks across various subareas of DOHaD research themes. Understanding how these advanced imaging techniques in animal models and human population studies can be both additively and synergistically used alongside traditional techniques in DOHaD-focussed laboratories is therefore of great interest. Global experts in advanced imaging techniques congregated at the advanced imaging workshop at the 2019 DOHaD World Congress in Melbourne, Australia. This review summarizes the presentations of new imaging modalities and novel applications to DOHaD research and discussions had by DOHaD researchers that are currently utilizing advanced imaging techniques including MRI, hyperpolarized MRI, ultrasound, and synchrotron-based techniques to aid their DOHaD research focus.
Collapse
Affiliation(s)
- Janna L Morrison
- Early Origins of Adult Health Research Group, Health and Biomedical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, SA, Australia
| | - Oyekoya T Ayonrinde
- Fiona Stanley Hospital, Murdoch, WA, Australia
- Medical School, The University of Western Australia, Perth, WA, Australia
| | - Alison S Care
- The Robinson Research Institute and Adelaide Medical School, University of Adelaide, Adelaide, SA, Australia
| | - Geoffrey D Clarke
- Department of Radiology, University of Texas Health Science Center, San Antonio, TX, USA
| | - Jack R T Darby
- Early Origins of Adult Health Research Group, Health and Biomedical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, SA, Australia
| | - Anna L David
- Elizabeth Garrett Anderson Institute for Women's Health, University College London, London, UK
| | - Justin M Dean
- Department of Physiology, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Stuart B Hooper
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, Victoria, Australia
- The Department of Obstetrics and Gynecology, Monash University, Melbourne, Victoria, Australia
| | - Marcus J Kitchen
- School of Physics and Astronomy, Monash University, Melbourne, Victoria, Australia
| | | | - Andrew Melbourne
- School of Biomedical Engineering and Imaging Sciences, Kings College London, London, UK
| | - Erin V McGillick
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, Victoria, Australia
- The Department of Obstetrics and Gynecology, Monash University, Melbourne, Victoria, Australia
| | - Charles A McKenzie
- Department of Medical Biophysics, Western University, London, ON, Canada
- Lawson Health Research Institute and Children's Health Research Institute, London, ON, Canada
| | - Navin Michael
- Singapore Institute for Clinical Sciences, Agency for Science, Technology, and Research (A*STAR), Singapore, Singapore
| | - Nuruddin Mohammed
- Maternal Fetal Medicine Unit, Department of Obstetrics and Gynecology, Aga Khan University Hospital, Karachi, Pakistan
| | - Suresh Anand Sadananthan
- Singapore Institute for Clinical Sciences, Agency for Science, Technology, and Research (A*STAR), Singapore, Singapore
| | - Eric Schrauben
- Translational Medicine, Hospital for Sick Children, Toronto, ON, Canada
| | - Timothy R H Regnault
- Lawson Health Research Institute and Children's Health Research Institute, London, ON, Canada
- Department of Obstetrics and Gynecology, Western University, London, ON, Canada
- Department of Physiology and Pharmacology, Western University, London, ON, Canada
| | - S Sendhil Velan
- Singapore Bioimaging Consortium, Agency for Science, Technology, and Research (A*STAR), Singapore, Singapore
- Singapore Institute for Clinical Sciences, Agency for Science, Technology, and Research (A*STAR), Singapore, Singapore
| |
Collapse
|
14
|
European Resuscitation Council Guidelines 2021: Newborn resuscitation and support of transition of infants at birth. Resuscitation 2021; 161:291-326. [PMID: 33773829 DOI: 10.1016/j.resuscitation.2021.02.014] [Citation(s) in RCA: 237] [Impact Index Per Article: 79.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The European Resuscitation Council has produced these newborn life support guidelines, which are based on the International Liaison Committee on Resuscitation (ILCOR) 2020 Consensus on Science and Treatment Recommendations (CoSTR) for Neonatal Life Support. The guidelines cover the management of the term and preterm infant. The topics covered include an algorithm to aid a logical approach to resuscitation of the newborn, factors before delivery, training and education, thermal control, management of the umbilical cord after birth, initial assessment and categorisation of the newborn infant, airway and breathing and circulation support, communication with parents, considerations when withholding and discontinuing support.
Collapse
|
15
|
Amarelle L, Quintela L, Hurtado J, Malacrida L. Hyperoxia and Lungs: What We Have Learned From Animal Models. Front Med (Lausanne) 2021; 8:606678. [PMID: 33768102 PMCID: PMC7985075 DOI: 10.3389/fmed.2021.606678] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 02/15/2021] [Indexed: 12/19/2022] Open
Abstract
Although oxygen (O2) is essential for aerobic life, it can also be an important source of cellular damage. Supra-physiological levels of O2 determine toxicity due to exacerbated reactive oxygen species (ROS) production, impairing the homeostatic balance of several cellular processes. Furthermore, injured cells activate inflammation cascades, amplifying the tissue damage. The lung is the first (but not the only) organ affected by this condition. Critically ill patients are often exposed to several insults, such as mechanical ventilation, infections, hypo-perfusion, systemic inflammation, and drug toxicity. In this scenario, it is not easy to dissect the effect of oxygen toxicity. Translational investigations with animal models are essential to explore injuring stimuli in controlled experimental conditions, and are milestones in understanding pathological mechanisms and developing therapeutic strategies. Animal models can resemble what happens in critical care or anesthesia patients under mechanical ventilation and hyperoxia, but are also critical to explore the effect of O2 on lung development and the role of hyperoxic damage on bronchopulmonary dysplasia. Here, we set out to review the hyperoxia effects on lung pathology, contributing to the field by describing and analyzing animal experimentation's main aspects and its implications on human lung diseases.
Collapse
Affiliation(s)
- Luciano Amarelle
- Department of Pathophysiology, Hospital de Clínicas, School of Medicine, Universidad de la República, Montevideo, Uruguay
| | - Lucía Quintela
- Department of Pathophysiology, Hospital de Clínicas, School of Medicine, Universidad de la República, Montevideo, Uruguay
| | - Javier Hurtado
- Department of Pathophysiology, Hospital de Clínicas, School of Medicine, Universidad de la República, Montevideo, Uruguay
| | - Leonel Malacrida
- Department of Pathophysiology, Hospital de Clínicas, School of Medicine, Universidad de la República, Montevideo, Uruguay.,Advanced Bioimaging Unit, Institut Pasteur Montevideo and Universidad de la República, Montevideo, Uruguay
| |
Collapse
|
16
|
Martherus T, Kuypers KLAM, Böhringer S, Dekker J, Witlox RSGM, Hooper SB, Te Pas AB. Feasibility and Effect of Physiological-Based CPAP in Preterm Infants at Birth. Front Pediatr 2021; 9:777614. [PMID: 34926350 PMCID: PMC8678466 DOI: 10.3389/fped.2021.777614] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 11/09/2021] [Indexed: 12/18/2022] Open
Abstract
Background: Preterm infants are commonly supported with 5-8 cmH2O CPAP. However, animal studies demonstrate that high initial CPAP levels (12-15 cmH2O) which are then reduced (termed physiological based (PB)-CPAP), improve lung aeration without adversely affecting cardiovascular function. We investigated the feasibility of PB-CPAP and the effect in preterm infants at birth. Methods: Preterm infants (24-30 weeks gestation) were randomized to PB-CPAP or 5-8 cmH2O CPAP for the first 10 min after birth. PB-CPAP consisted of 15 cmH2O CPAP that was decreased when infants were stabilized (heart rate ≥100 bpm, SpO2 ≥85%, FiO2 ≤ 0.4, spontaneous breathing) to 8 cmH2O with steps of ~2/3 cmH2O/min. Primary outcomes were feasibility and SpO2 in the first 5 min after birth. Secondary outcomes included physiological and breathing parameters and short-term neonatal outcomes. Planned enrollment was 42 infants. Results: The trial was stopped after enrolling 31 infants due to a low inclusion rate and recent changes in the local resuscitation guideline that conflict with the study protocol. Measurements were available for analysis in 28 infants (PB-CPAP n = 8, 5-8 cmH2O n = 20). Protocol deviations in the PB-CPAP group included one infant receiving 3 inflations with 15 cmH2O PEEP and two infants in which CPAP levels were decreased faster than described in the study protocol. In the 5-8 cmH2O CPAP group, three infants received 4, 10, and 12 cmH2O CPAP. During evaluations, caregivers indicated that the current PB-CPAP protocol was difficult to execute. The SpO2 in the first 5 min after birth was not different [61 (49-70) vs. 64 (47-74), p = 0.973]. However, infants receiving PB-CPAP achieved higher heart rates [121 (111-130) vs. 97 (82-119) bpm, p = 0.016] and duration of mask ventilation was shorter [0:42 (0:34-2:22) vs. 2:58 (1:36-6:03) min, p = 0.020]. Infants in the PB-CPAP group required 6:36 (5:49-11:03) min to stabilize, compared to 9:57 (6:58-15:06) min in the 5-8 cmH2O CPAP group (p = 0.256). There were no differences in short-term outcomes. Conclusion: Stabilization of preterm infants with PB-CPAP is feasible but tailoring CPAP appeared challenging. PB-CPAP did not lead to higher SpO2 but increased heart rate and shortened the duration of mask ventilation, which may reflect faster lung aeration.
Collapse
Affiliation(s)
- Tessa Martherus
- Division of Neonatology, Department of Pediatrics, Willem-Alexander Children's Hospital, Leiden University Medical Center, Leiden, Netherlands
| | - Kristel L A M Kuypers
- Division of Neonatology, Department of Pediatrics, Willem-Alexander Children's Hospital, Leiden University Medical Center, Leiden, Netherlands
| | - Stefan Böhringer
- Department of Biomedical Data Sciences, Leiden University Medical Center, Leiden, Netherlands
| | - Janneke Dekker
- Division of Neonatology, Department of Pediatrics, Willem-Alexander Children's Hospital, Leiden University Medical Center, Leiden, Netherlands
| | - Ruben S G M Witlox
- Division of Neonatology, Department of Pediatrics, Willem-Alexander Children's Hospital, Leiden University Medical Center, Leiden, Netherlands
| | - Stuart B Hooper
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia.,Department of Obstetrics and Gynecology, Monash University, Melbourne, VIC, Australia
| | - Arjan B Te Pas
- Division of Neonatology, Department of Pediatrics, Willem-Alexander Children's Hospital, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|
17
|
Abstract
The European Resuscitation Council has produced these newborn life support guidelines, which are based on the International Liaison Committee on Resuscitation (ILCOR) 2020 Consensus on Science and Treatment Recommendations (CoSTR) for Neonatal Life Support. The guidelines cover the management of the term and preterm infant. The topics covered include an algorithm to aid a logical approach to resuscitation of the newborn, factors before delivery, training and education, thermal control, management of the umbilical cord after birth, initial assessment and categorisation of the newborn infant, airway and breathing and circulation support, communication with parents, considerations when withholding and discontinuing support.
Collapse
|
18
|
Optimizing Oxygenation of the Extremely Premature Infant during the First Few Minutes of Life: Start Low or High? J Pediatr 2020; 227:295-299. [PMID: 32663594 DOI: 10.1016/j.jpeds.2020.07.034] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 07/02/2020] [Accepted: 07/08/2020] [Indexed: 02/04/2023]
|
19
|
Dekker J, Martherus T, Lopriore E, Giera M, McGillick EV, Hutten J, van Leuteren RW, van Kaam AH, Hooper SB, Te Pas AB. The Effect of Initial High vs. Low FiO 2 on Breathing Effort in Preterm Infants at Birth: A Randomized Controlled Trial. Front Pediatr 2019; 7:504. [PMID: 31921719 PMCID: PMC6927294 DOI: 10.3389/fped.2019.00504] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Accepted: 11/21/2019] [Indexed: 11/13/2022] Open
Abstract
Background: Infants are currently stabilized at birth with initial low FiO2 which increases the risk of hypoxia and suppression of breathing in the first minutes after birth. We hypothesized that initiating stabilization at birth with a high O2 concentration, followed by titration, would improve breathing effort when compared to a low O2 concentration, followed by titration. Methods: In a bi-center randomized controlled trial, infants <30 weeks gestation were stabilized at birth with an initial O2 concentration of 30 or 100%, followed by oxygen titration. Primary outcome was minute volume of spontaneous breathing. We also assessed tidal volumes, mean inspiratory flow rate (MIFR) and respiratory rate with a respiratory function monitor in the first 5 min after birth, and evaluated the duration of mask ventilation in the first 10 min after birth. Pulse oximetry was used to measure heart rate and SpO2 values in the first 10 min. Hypoxemia was defined as SpO2 < 25th percentile and hyperoxemia as SpO2 >95%. 8-iso-prostaglandin F2α (8iPGF2α) was measured to assess oxidative stress in cord blood and 1 and 24 h after birth. Results: Fifty-two infants were randomized and recordings were obtained in 44 infants (100% O2-group: n = 20, 30% O2-group: n = 24). Minute volumes were significantly higher in the 100% O2-group (146.34 ± 112.68 mL/kg/min) compared to the 30% O2-group (74.43 ± 52.19 mL/kg/min), p = 0.014. Tidal volumes and MIFR were significantly higher in the 100% O2-group, while the duration of mask ventilation given was significantly shorter. Oxygenation in the first 5 min after birth was significantly higher in infants in the 100% O2-group [85 (64-93)%] compared to the 30% O2-group [58 (46-67)%], p < 0.001. The duration of hypoxemia was significantly shorter in the 100% O2-group, while the duration of hyperoxemia was not different between groups. There was no difference in oxidative stress marker 8iPGF2α between the groups. Conclusion: Initiating stabilization of preterm infants at birth with 100% O2 led to higher breathing effort, improved oxygenation, and a shorter duration of mask ventilation as compared to 30% O2, without increasing the risk for hyperoxia or oxidative stress. Clinical Trial Registration: This study was registered in www.trialregister.nl, with registration number NTR6878.
Collapse
Affiliation(s)
- Janneke Dekker
- Department of Neonatology, Leiden University Medical Center, Leiden, Netherlands
| | - Tessa Martherus
- Department of Neonatology, Leiden University Medical Center, Leiden, Netherlands
| | - Enrico Lopriore
- Department of Neonatology, Leiden University Medical Center, Leiden, Netherlands
| | - Martin Giera
- Center Proteomics Metabolomics, Leiden University Medical Center, Leiden, Netherlands
| | - Erin V McGillick
- The Ritchie Centre, Hudson Institute for Medical Research, Melbourne, VIC, Australia.,Department of Obstetrics and Gynaecology, Monash University, Melbourne, VIC, Australia
| | - Jeroen Hutten
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Ruud W van Leuteren
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Anton H van Kaam
- Department of Neonatology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Stuart B Hooper
- The Ritchie Centre, Hudson Institute for Medical Research, Melbourne, VIC, Australia.,Department of Obstetrics and Gynaecology, Monash University, Melbourne, VIC, Australia
| | - Arjan B Te Pas
- Department of Neonatology, Leiden University Medical Center, Leiden, Netherlands
| |
Collapse
|