1
|
Awad H, El-Brolossy TA, Abdallah T, Osman A, Negm S, Mansour OI, Girgis SA, Hafez HM, Zaki AM, Talaat H. Accurate and reliable surface-enhanced Raman spectroscopy assay for early detection of SARS-CoV-2 RNA with exceptional sensitivity. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 315:124184. [PMID: 38608556 DOI: 10.1016/j.saa.2024.124184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 02/28/2024] [Accepted: 03/22/2024] [Indexed: 04/14/2024]
Abstract
This research proposes a highly sensitive and simple surface-enhanced Raman spectroscopy (SERS) assay for the detection of SARS-CoV-2 RNA using suitably designed probes specific for RdRp and N viral genes attached to a Raman marker. The sensitivity of the assay was optimized through precise adjustments to the conditions of immobilization and hybridization processes of the target RNA, including modifications to factors such as time and temperature. The assay achieved a remarkable sensitivity down to 58.39 copies/mL, comparable to or lower than the sensitivities reported for commercial fluorescent polymerase chain reaction (PCR) based methods. It has good selectivity in discriminating SARS-CoV-2 RNA against other respiratory viruses, respiratory syncytial virus (RSV), and influenza A virus. The reliability of the assay was validated by testing 24 clinical samples, including 12 positive samples with varying cycle threshold (Ct) values and 12 negative samples previously tested using real-time PCR. The assay consistently predicted true results that were in line with the PCR results for all samples. Furthermore, the assay demonstrated a notable limit of detection (LOD) of Ct (38 for RdRp gene and 37.5 for N-gene), indicating its capability to detect low concentrations of the target analyte and potentially facilitating early detection of the pathogen.
Collapse
Affiliation(s)
- Hend Awad
- Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt
| | | | - Tamer Abdallah
- Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt
| | - Ahmed Osman
- Institute of Basic and Applied Science - Egpt-Japan University of Science and Technology (E-JUST), Egypt
| | - Sohair Negm
- Department of Physics and Mathematics, Banha University, Banha, Egypt
| | | | | | - Hala M Hafez
- Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Ali M Zaki
- Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Hassan Talaat
- Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt
| |
Collapse
|
2
|
Cao Q, Liu Y, Yang L, Tan T, He J, Chen W, Li R, Wang W. Popcorn-like bimetallic palladium/platinum exhibiting enhanced peroxidase-like activity for signal enhancement in lateral flow immunoassay. Anal Chim Acta 2024; 1309:342698. [PMID: 38772661 DOI: 10.1016/j.aca.2024.342698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 05/06/2024] [Indexed: 05/23/2024]
Abstract
BACKGROUND The lateral flow immunoassay (LFIA) is widely employed as a point-of-care testing (POCT) technique. However, its limited sensitivity hinders its application in detecting biomarkers with low abundance. Recently, the utilization of nanozymes has been implemented to enhance the sensitivity of LFIA by catalyzing the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB). The catalytic performance of nanozymes plays a crucial role in influencing the sensitivity of LFIA. RESULTS The Cornus officinalis Sieb. et Zucc-Pd@Pt (CO-Pd@Pt) nanozyme with good peroxidase-like activity was synthesized herein through a facile one-pot method employing Cornus officinalis Sieb. et Zucc extract as a reducing agent. The morphology and composition of the CO-Pd@Pt nanozyme were characterized using TEM, SEM, XRD, and XPS. As a proof of concept, the as-synthesized CO-Pd@Pt nanozyme was utilized in LFIA (CO-Pd@Pt-LFIA) for the detection of human chorionic gonadotropin (hCG). Compared to conventional gold nanoparticles-based LFIA (AuNPs-LFIA), CO-Pd@Pt-LFIA demonstrated a significant enhancement in the limit of detection (LOD, 0.08 mIU/mL), which is approximately 160 times lower than that of AuNPs-LFIA. Furthermore, experiments evaluating accuracy, precision, selectivity, interference, and stability have confirmed the practical applicability of CO-Pd@Pt-LFIA for hCG content determination. SIGNIFICANCE The present study presents a novel approach for the synthesis of bimetallic nanozymes through environmentally friendly methods, utilizing plant extracts as both protective and reducing agents. Additionally, an easily implementable technique is proposed to enhance signal detection in lateral flow immunoassays.
Collapse
Affiliation(s)
- Qianqian Cao
- Institute of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, HengYang, 421000, Hunan, China
| | - Yiqin Liu
- Institute of Pathogenic Biology, Hengyang Medical School, University of South China, Hengyang, 421000, Hunan, China
| | - Lin Yang
- Institute of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, HengYang, 421000, Hunan, China
| | - Ting Tan
- Institute of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, HengYang, 421000, Hunan, China
| | - Jian He
- Institute of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, HengYang, 421000, Hunan, China
| | - Weiwei Chen
- Institute of Pathogenic Biology, Hengyang Medical School, University of South China, Hengyang, 421000, Hunan, China
| | - Ranhui Li
- Institute of Pathogenic Biology, Hengyang Medical School, University of South China, Hengyang, 421000, Hunan, China.
| | - Weiguo Wang
- Institute of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, HengYang, 421000, Hunan, China.
| |
Collapse
|
3
|
Kaewarsa P, Schenkel MS, Rahn KL, Laiwattanapaisal W, Henry CS. Improving design features and air bubble manipulation techniques for a single-step sandwich electrochemical ELISA incorporating commercial electrodes into capillary-flow driven immunoassay devices. Analyst 2024; 149:2034-2044. [PMID: 38407468 PMCID: PMC10962017 DOI: 10.1039/d3an01704d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 02/15/2024] [Indexed: 02/27/2024]
Abstract
Integrating electrochemistry into capillary-flow driven immunoassay devices provides unique opportunities for quantitative point-of-care testing. Although custom electrodes can be inexpensive and are tunable, they require skilled fabrication. Here, we report the incorporation of a commercial electrode into a capillary-flow driven immunoassay (iceCaDI) device for a single end-user step sandwich electrochemical enzyme-linked immunosorbent assay (ELISA). The iceCaDI device is a pump-free portable microfluidic device with an integrated commercial screen-printed electrode and flow driven by capillary action. The iceCaDI device is composed of alternating polyester transparency film and double-sided adhesive film layers that are patterned with a laser cutter. This platform was designed to address known limitations of laminated device fabrication methods and operation. First, we developed a foldable laminated device fabrication using hinges for easy assembly and precise alignment. Second, reagent dispersing was achieved by incorporating a 1 mm wide arrow-shaped notch in the middle of the channel that trapped an air bubble and formed a baffle that facilitated reagent spreading to cover the detection area. Third, small vent holes were added to the top layer of the channels to prevent air bubbles from blocking flow. Finally, we fabricated a CRP immunosensor with a detection range of 0.625 to 10.0 μg mL-1 as a proof-of-concept to demonstrate an automatically driven sandwich electrochemical ELISA using the iceCaDI device. Three concentrations of CRP were successfully measured under flow conditions within 8 min. Our proposed device is a promising approach and a step forward in the development of point-of-care (POC) devices for techniques that traditionally require multiple user steps.
Collapse
Affiliation(s)
- Phuritat Kaewarsa
- Graduate Program in Clinical Biochemistry and Molecular Medicine, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Melissa S Schenkel
- Department of Chemistry, Colorado State, University, Fort Collins, Colorado, 80526, USA
| | - Kira L Rahn
- Department of Chemistry, Colorado State, University, Fort Collins, Colorado, 80526, USA
| | - Wanida Laiwattanapaisal
- Biosensors and Bioanalytical Technology for Cell and Innovative Testing Research Unit, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Charles S Henry
- Department of Chemistry, Colorado State, University, Fort Collins, Colorado, 80526, USA
- Materials and Metallurgy Research Institute, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
4
|
Wang W, Srivastava S, Garg A, Xiao C, Hawks S, Pan J, Duggal N, Isaacman-VanWertz G, Zhou W, Marr LC, Vikesland PJ. Digital Surface-Enhanced Raman Spectroscopy-Lateral Flow Test Dipstick: Ultrasensitive, Rapid Virus Quantification in Environmental Dust. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:4926-4936. [PMID: 38452107 PMCID: PMC10956432 DOI: 10.1021/acs.est.3c10311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Revised: 02/15/2024] [Accepted: 02/20/2024] [Indexed: 03/09/2024]
Abstract
This study introduces a novel surface-enhanced Raman spectroscopy (SERS)-based lateral flow test (LFT) dipstick that integrates digital analysis for highly sensitive and rapid viral quantification. The SERS-LFT dipsticks, incorporating gold-silver core-shell nanoparticle probes, enable pixel-based digital analysis of large-area SERS scans. Such an approach enables ultralow-level detection of viruses that readily distinguishes positive signals from background noise at the pixel level. The developed digital SERS-LFTs demonstrate limits of detection (LODs) of 180 fg for SARS-CoV-2 spike protein, 120 fg for nucleocapsid protein, and 7 plaque forming units for intact virus, all within <30 min. Importantly, digital SERS-LFT methods maintain their robustness and their LODs in the presence of indoor dust, thus underscoring their potential for accurate and reliable virus diagnosis and quantification in real-world environmental settings.
Collapse
Affiliation(s)
- Wei Wang
- Department
of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
- Virginia
Tech Institute of Critical Technology and Applied Science (ICTAS)
Sustainable Nanotechnology Center (VTSuN), Blacksburg, Virginia 24061, United States
| | - Sonali Srivastava
- Department
of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
- Virginia
Tech Institute of Critical Technology and Applied Science (ICTAS)
Sustainable Nanotechnology Center (VTSuN), Blacksburg, Virginia 24061, United States
| | - Aditya Garg
- Department
of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Chuan Xiao
- Department
of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Seth Hawks
- Department
of Biomedical Sciences and Pathobiology, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Jin Pan
- Department
of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Nisha Duggal
- Department
of Biomedical Sciences and Pathobiology, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Gabriel Isaacman-VanWertz
- Department
of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Wei Zhou
- Department
of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Linsey C. Marr
- Department
of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
- Virginia
Tech Institute of Critical Technology and Applied Science (ICTAS)
Sustainable Nanotechnology Center (VTSuN), Blacksburg, Virginia 24061, United States
| | - Peter J. Vikesland
- Department
of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
- Virginia
Tech Institute of Critical Technology and Applied Science (ICTAS)
Sustainable Nanotechnology Center (VTSuN), Blacksburg, Virginia 24061, United States
| |
Collapse
|
5
|
Russo A, Cavalera S, Murray R, Lovera P, Quinn A, Anfossi L, Iacopino D. Pen direct writing of SERRS-based lateral flow assays for detection of penicillin G in milk. NANOSCALE ADVANCES 2024; 6:1524-1534. [PMID: 38419877 PMCID: PMC10898433 DOI: 10.1039/d3na00846k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 02/10/2024] [Indexed: 03/02/2024]
Abstract
Direct pen writing offers versatile opportunities for development of low-cost tests for point-of-care applications. In this work a lateral flow immunoassay (LFIA) test was fabricated by hand "writing" immunoprobes onto hand-cut nitrocellulose strips with a commercial fountain pen. The qualitative capabilities of the test were extended by addition of a Raman reporter and consequent design and fabrication of a Surface Enhanced Resonant Raman Scattering (SERRS)-LFIA test. As proof-of-concept, dual detection of penicillin G was achieved in milk with a visual LOD of 20 ppm and a dynamic range of 0.03-97.5 ppm. Evaluation against equivalent tests performed with conventionally prepared LFIA strips showed comparable results, thus demonstrating the validity of the test. These results demonstrate the potential for further decrease in cost and consequent broader use of LFIA tests in remote regions and resource-limited environments.
Collapse
Affiliation(s)
- Alida Russo
- Tyndall National Institute, University College Cork Lee Maltings Complex, Dyke Parade T12R5CP Cork Ireland
| | - Simone Cavalera
- Department of Chemistry, University of Turin Via P. Giuria 5 10125 Turin Italy
| | - Richard Murray
- Tyndall National Institute, University College Cork Lee Maltings Complex, Dyke Parade T12R5CP Cork Ireland
| | - Pierre Lovera
- Tyndall National Institute, University College Cork Lee Maltings Complex, Dyke Parade T12R5CP Cork Ireland
| | - Aidan Quinn
- Tyndall National Institute, University College Cork Lee Maltings Complex, Dyke Parade T12R5CP Cork Ireland
| | - Laura Anfossi
- Department of Chemistry, University of Turin Via P. Giuria 5 10125 Turin Italy
| | - Daniela Iacopino
- Tyndall National Institute, University College Cork Lee Maltings Complex, Dyke Parade T12R5CP Cork Ireland
| |
Collapse
|
6
|
Yu Q, Wu T, Tian B, Li J, Liu Y, Wu Z, Jin X, Wang C, Wang C, Gu B. Recent advances in SERS-based immunochromatographic assay for pathogenic microorganism diagnosis: A review. Anal Chim Acta 2024; 1286:341931. [PMID: 38049231 DOI: 10.1016/j.aca.2023.341931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/02/2023] [Accepted: 10/17/2023] [Indexed: 12/06/2023]
Abstract
Infectious diseases caused by bacteria, viruses, fungi, and other pathogenic microorganisms are among the most harmful public health problems in the world, causing tens of millions of deaths and incalculable economic losses every year. The establishment of rapid, simple, and highly sensitive diagnostic methods for pathogenic microorganisms is important for the prevention and control of infectious diseases, guidance of timely treatment, and the reduction of public safety risks. Lateral flow immunoassay (LFA) based on the colorimetric signal of colloidal gold is the most popular point-of-care testing technology at present, but it is limited by poor sensitivity and low throughput and hardly meets the needs of the highly sensitive screening of pathogenic microorganisms. In recent years, the combination of surface-enhanced Raman scattering (SERS) and LFA technology has developed into a novel analytical platform with high sensitivity and multiple detection capabilities and has shown great advantages in the detection of pathogenic microorganisms and infectious diseases. This review summarizes the working principle, design ideas, and application of the existing SERS-based LFA methods in pathogenic microorganism detection and further introduces the effect of new technologies such as Raman signal encoding, magnetic enrichment, novel membrane nanotags, and integrated Raman reading equipment on the performance of SERS-LFA. Finally, the main challenges and the future direction of development in this field of SERS-LFA are discussed.
Collapse
Affiliation(s)
- Qing Yu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, China
| | - Ting Wu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Benshun Tian
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Jiaxuan Li
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Yun Liu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China
| | - Zelan Wu
- Guangzhou Labway Clinical Laboratory Co., Ltd, Guangdong, 510000, China
| | - Xiong Jin
- Guangzhou Labway Clinical Laboratory Co., Ltd, Guangdong, 510000, China
| | - Chaoguang Wang
- College of Intelligence Science and Technology, National University of Defense Technology, Changsha, 410073, China.
| | - Chongwen Wang
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China; College of Life Sciences, Anhui Agricultural University, Hefei, 230036, China.
| | - Bing Gu
- Department of Clinical Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510000, China.
| |
Collapse
|
7
|
Kim YJ, Min J. Advances in nanobiosensors during the COVID-19 pandemic and future perspectives for the post-COVID era. NANO CONVERGENCE 2024; 11:3. [PMID: 38206526 PMCID: PMC10784265 DOI: 10.1186/s40580-023-00410-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 12/07/2023] [Indexed: 01/12/2024]
Abstract
The unprecedented threat of the highly contagious virus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes exponentially increased infections of coronavirus disease 2019 (COVID-19), highlights the weak spots of the current diagnostic toolbox. In the midst of catastrophe, nanobiosensors offer a new opportunity as an alternative tool to fill a gap among molecular tests, rapid antigen tests, and serological tests. Nanobiosensors surpass the potential of antigen tests because of their enhanced sensitivity, thus enabling us to see antigens as stable and easy-to-access targets. During the first three years of the COVID-19 pandemic, a substantial number of studies have reported nanobiosensors for the detection of SARS-CoV-2 antigens. The number of articles on nanobiosensors and SARS-CoV-2 exceeds the amount of nanobiosensor research on detecting previous infectious diseases, from influenza to SARS-CoV and MERS-CoV. This unprecedented publishing pace also implies the significance of SARS-CoV-2 and the present pandemic. In this review, 158 studies reporting nanobiosensors for detecting SARS-CoV-2 antigens are collected to discuss the current challenges of nanobiosensors using the criteria of point-of-care (POC) diagnostics along with COVID-specific issues. These advances and lessons during the pandemic pave the way for preparing for the post-COVID era and potential upcoming infectious diseases.
Collapse
Affiliation(s)
- Young Jun Kim
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea
| | - Junhong Min
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea.
| |
Collapse
|
8
|
Lee S, Bi L, Chen H, Lin D, Mei R, Wu Y, Chen L, Joo SW, Choo J. Recent advances in point-of-care testing of COVID-19. Chem Soc Rev 2023; 52:8500-8530. [PMID: 37999922 DOI: 10.1039/d3cs00709j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2023]
Abstract
Advances in microfluidic device miniaturization and system integration contribute to the development of portable, handheld, and smartphone-compatible devices. These advancements in diagnostics have the potential to revolutionize the approach to detect and respond to future pandemics. Accordingly, herein, recent advances in point-of-care testing (POCT) of coronavirus disease 2019 (COVID-19) using various microdevices, including lateral flow assay strips, vertical flow assay strips, microfluidic channels, and paper-based microfluidic devices, are reviewed. However, visual determination of the diagnostic results using only microdevices leads to many false-negative results due to the limited detection sensitivities of these devices. Several POCT systems comprising microdevices integrated with portable optical readers have been developed to address this issue. Since the outbreak of COVID-19, effective POCT strategies for COVID-19 based on optical detection methods have been established. They can be categorized into fluorescence, surface-enhanced Raman scattering, surface plasmon resonance spectroscopy, and wearable sensing. We introduced next-generation pandemic sensing methods incorporating artificial intelligence that can be used to meet global health needs in the future. Additionally, we have discussed appropriate responses of various testing devices to emerging infectious diseases and prospective preventive measures for the post-pandemic era. We believe that this review will be helpful for preparing for future infectious disease outbreaks.
Collapse
Affiliation(s)
- Sungwoon Lee
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
| | - Liyan Bi
- School of Special Education and Rehabilitation, Binzhou Medical University, Yantai, 264003, China
| | - Hao Chen
- School of Environmental and Material Engineering, Yantai University, Yantai 264005, China
| | - Dong Lin
- School of Pharmacy, Bianzhou Medical University, Yantai, 264003, China
| | - Rongchao Mei
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Yantai 264003, China
| | - Yixuan Wu
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Yantai 264003, China
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Yantai 264003, China
- School of Pharmacy, Bianzhou Medical University, Yantai, 264003, China
| | - Sang-Woo Joo
- Department of Information Communication, Materials, and Chemistry Convergence Technology, Soongsil University, Seoul 06978, South Korea
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea.
| |
Collapse
|
9
|
Akalın P, Yazgan-Karataş A. Development of a nucleic acid-based lateral flow device as a reliable diagnostic tool for respiratory viral infections. MethodsX 2023; 11:102372. [PMID: 37744884 PMCID: PMC10511794 DOI: 10.1016/j.mex.2023.102372] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Accepted: 09/08/2023] [Indexed: 09/26/2023] Open
Abstract
Viral infections continue to pose a significant threat to the public health, leading to high morbidity and mortality rates worldwide. To combat these challenges, early detection and treatment are essential in reducing hospitalizations and preventing severe complications. Simple, inexpensive, and sensitive diagnostic methods are in constant demand in many areas. In this study, we report the development of a nucleic acid-based lateral flow immunoassay device (NALFIA) and demonstrate its successful application in conjunction with a multiplexed reverse-transcription loop-mediated isothermal amplification assay (LAMP) for the detection of SARS-CoV-2 and influenza. In our approach the NALFIA part preparation is independent of the target, and has the potential to ensure widespread use in diagnostics particularly where testing speed is critical such as in respiratory viral infections.•Simple, inexpensive, sensitive and reliable rapid diagnostic tool.•Target independent design.•Effective use for respiratory samples due to practical sample extraction.
Collapse
Affiliation(s)
- Pınar Akalın
- Dr. Orhan Öcalgiray Molecular Biology, Biotechnology and Genetics Research Center (ITU-MOBGAM), Istanbul Technical University, Maslak 34469, Istanbul, Turkey
| | - Ayten Yazgan-Karataş
- Dr. Orhan Öcalgiray Molecular Biology, Biotechnology and Genetics Research Center (ITU-MOBGAM), Istanbul Technical University, Maslak 34469, Istanbul, Turkey
- Faculty of Science and Letters, Department of Molecular Biology and Genetics, Istanbul Technical University, Maslak 34469 Istanbul, Turkey
| |
Collapse
|
10
|
Khristoforova Y, Bratchenko L, Bratchenko I. Raman-Based Techniques in Medical Applications for Diagnostic Tasks: A Review. Int J Mol Sci 2023; 24:15605. [PMID: 37958586 PMCID: PMC10647591 DOI: 10.3390/ijms242115605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 10/23/2023] [Accepted: 10/24/2023] [Indexed: 11/15/2023] Open
Abstract
Raman spectroscopy is a widely developing approach for noninvasive analysis that can provide information on chemical composition and molecular structure. High chemical specificity calls for developing different medical diagnostic applications based on Raman spectroscopy. This review focuses on the Raman-based techniques used in medical diagnostics and provides an overview of such techniques, possible areas of their application, and current limitations. We have reviewed recent studies proposing conventional Raman spectroscopy and surface-enhanced Raman spectroscopy for rapid measuring of specific biomarkers of such diseases as cardiovascular disease, cancer, neurogenerative disease, and coronavirus disease (COVID-19). As a result, we have discovered several most promising Raman-based applications to identify affected persons by detecting some significant spectral features. We have analyzed these approaches in terms of their potentially diagnostic power and highlighted the remaining challenges and limitations preventing their translation into clinical settings.
Collapse
Affiliation(s)
| | | | - Ivan Bratchenko
- Department of Laser and Biotechnical Systems, Samara National Research University, 34 Moskovskoye Shosse, Samara 443086, Russia; (Y.K.)
| |
Collapse
|
11
|
Sensitive detection of SARS-CoV-2 spike protein based on electrochemical impedance spectroscopy of Fe 3O 4@SiO 2–Au/GCE biosensor. ADVANCED SENSOR AND ENERGY MATERIALS 2023; 2:100067. [PMCID: PMC10212796 DOI: 10.1016/j.asems.2023.100067] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 05/23/2023] [Accepted: 05/24/2023] [Indexed: 02/25/2024]
Abstract
Highly contagious COVID-19 disease is caused by a novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which poses a serious threat to global public health. Therefore, the development of a fast and reliable method for the detection of SARS-CoV-2 is an urgent research need. The Fe3O4@SiO2–Au is enriched with a variety of functional groups, which can be used to fabricate a sensitive electrochemical biosensor by biofunctionalization with angiotensin-converting enzyme 2 (ACE2). Accordingly, we developed a novel electrochemical sensor by chemically modifying a glassy carbon electrode (GCE) with Fe3O4@SiO2–Au nanocomposites (hereafter Fe3O4@SiO2–Au/GCE) for the rapid detection of S-protein spiked SARS-CoV-2 by electrochemical impedance spectroscopy (EIS). The new electrochemical sensor has a low limit detection (viz., 4.78 pg/mL) and a wide linear dynamic range (viz., 0.1 ng/mL to 10 μg/mL) for detecting the EIS response signal of S-protein. The robust Fe3O4@SiO2–Au/GCE biosensor has high selectivity, stability, and reproducibility for the detection of S-protein with good recovery of saliva samples.
Collapse
|
12
|
Yoon S, Lim YK, Kweon OJ, Kim TH, Lee MK. Clinical performance of SARS-CoV-2 antigen-detection rapid diagnostic test using SERS-based lateral flow immunoassay. Heliyon 2023; 9:e19492. [PMID: 37809408 PMCID: PMC10558587 DOI: 10.1016/j.heliyon.2023.e19492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/16/2023] [Accepted: 08/24/2023] [Indexed: 10/10/2023] Open
Abstract
Background 'ACROSIS COVID-19 Ag (NPS)' kit (SG Medical, Seoul, Korea) is a newly developed severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen-detection rapid diagnostic test (Ag-RDT) using surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFIA). We evaluated its clinical performance compared with STANDARD Q COVID-19 Ag (SD Biosensor, Suwon, Korea), a previously approved Ag-RDT. Methods A total of 286 nasopharyngeal swab specimens were collected: 104 positive and 182 negative specimens in SARS-CoV-2 real-time reverse-transcription polymerase-chain-reaction (rRT-PCR). SARS-CoV-2-positive specimens were divided according to the cycle threshold (Ct) value in rRT-PCR. The clinical performance of ACROSIS was compared with that of STANDARD Q. Results ACROSIS showed significantly higher sensitivity than STANDARD Q (92.3% vs. 85.6%, P = 0.02), especially in specimens with 25 ≤ Ct < 30 (78.6% vs. 42.9%). The Ct values of RdRp/S genes for 95% detection rates by ACROSIS and STANDARD Q were 25.8 and 23.0, respectively. Conclusions This is the first study that evaluated the performance of ACROSIS compared with STANDARD Q. The overall clinical performance of ACROSIS was superior to that of STANDARD Q, especially in specimens with 25 ≤ Ct < 30. ACROSIS could be useful for SARS-CoV-2 Ag detection even in relatively low viral load specimens.
Collapse
Affiliation(s)
- Sumi Yoon
- Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Yong Kwan Lim
- Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Oh Joo Kweon
- Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Tae-Hyoung Kim
- Department of Urology, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Mi-Kyung Lee
- Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea
| |
Collapse
|
13
|
Yu H, Yang Z, Fu S, Zhang Y, Panneerselvamc R, Li B, Zhang L, Chen Z, Wang X, Li J. Intelligent convolution neural network-assisted SERS to realize highly accurate identification of six pathogenic Vibrio. Chem Commun (Camb) 2023; 59:5779-5782. [PMID: 37096554 DOI: 10.1039/d3cc01129a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2023]
Abstract
Based on label-free SERS technology, the relationship between the Raman signals of pathogenic Vibrio microorganisms and purine metabolites was analyzed in detail. A deep learning CNN model was successfully developed, achieving a high accuracy rate of 99.7% in the identification of six typical pathogenic Vibrio species within 15 minutes, providing a new method for pathogen identification.
Collapse
Affiliation(s)
- Hui Yu
- College of Materials, State Key Laboratory for Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, School of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
| | - Zhilan Yang
- College of Materials, State Key Laboratory for Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, School of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
| | - Shiying Fu
- College of Materials, State Key Laboratory for Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, School of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
| | - Yuejiao Zhang
- College of Materials, State Key Laboratory for Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, School of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
| | | | - Baoqiang Li
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
| | - Lin Zhang
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China.
| | - Zehui Chen
- Xiamen City Center for Disease Control and Prevention, Xiamen 361005, China.
| | - Xin Wang
- College of Materials, State Key Laboratory for Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, School of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
| | - Jianfeng Li
- College of Materials, State Key Laboratory for Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, College of Energy, School of Aerospace Engineering, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
14
|
Alhabbab RY. Lateral Flow Immunoassays for Detecting Viral Infectious Antigens and Antibodies. MICROMACHINES 2022; 13:1901. [PMID: 36363922 PMCID: PMC9694796 DOI: 10.3390/mi13111901] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 10/14/2022] [Accepted: 10/19/2022] [Indexed: 05/28/2023]
Abstract
Abundant immunological assays currently exist for detecting pathogens and identifying infected individuals, making detection of diseases at early stages integral to preventing their spread, together with the consequent emergence of global health crises. Lateral flow immunoassay (LFIA) is a test characterized by simplicity, low cost, and quick results. Furthermore, LFIA testing does not need well-trained individuals or laboratory settings. Therefore, it has been serving as an attractive tool that has been extensively used during the ongoing COVID-19 pandemic. Here, the LFIA strip's available formats, reporter systems, components, and preparation are discussed. Moreover, this review provides an overview of the current LFIAs in detecting infectious viral antigens and humoral responses to viral infections.
Collapse
Affiliation(s)
- Rowa Y. Alhabbab
- Vaccines and Immunotherapy Unit, King Fahad Medical Research Center, King Abdulaziz University, Jeddah 21589, Saudi Arabia;
- Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| |
Collapse
|
15
|
Torres-Torres C, García-Pérez BE. Fundamentals of SARS-CoV-2 Biosensors. BIOSENSORS 2022; 12:880. [PMID: 36291016 PMCID: PMC9599352 DOI: 10.3390/bios12100880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
A beautiful topic in its essence and content is represented by the powerful assistance of sensing methods and techniques for automatically revealing biological agents and biological functions in this era [...].
Collapse
Affiliation(s)
- Carlos Torres-Torres
- Sección de Estudios de Posgrado e Investigación, Escuela Superior de Ingeniería Mecánica y Eléctrica Unidad Zacatenco, Instituto Politécnico Nacional, Mexico City 07738, Mexico
| | - Blanca Estela García-Pérez
- Departamento de Microbiología, Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Mexico City 11340, Mexico
| |
Collapse
|
16
|
Song T, Zhang L, Guo Z, Hong Q, Zheng K, Wu Y, Cao H, Liao M, Fang Q. Sensitive Immunochromatographic Assay (ICA) for the Determination of Thiamethoxam in Fruit, Vegetables, and Natural Water. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2110257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Tianwei Song
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Linwei Zhang
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
| | - Zhihui Guo
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Qiwen Hong
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
| | - Kang Zheng
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
| | - Yancan Wu
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Hefei Inspection Center for Agricultural Products Quality, Anhui Province, Hefei, China
| | - Haiqun Cao
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Min Liao
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| | - Qingkui Fang
- School of Plant Protection, Provincial Key Laboratory for Agri-Food Safety, Anhui Agricultural University, Hefei, China
- Anhui Province Key Laboratory of Integrated Pest Management on Crops, Anhui Agricultural University, Hefei, China
- Anhui Province Engineering Laboratory for Green Pesticide Development and Application, Anhui Agricultural University, Hefei, China
| |
Collapse
|
17
|
Abstract
Rapid and early diagnosis of lethal coronavirus disease-19 (COVID-19) caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is an important issue considering global human health, economy, education, and other activities. The advancement of understanding of the chemistry/biochemistry and the structure of the SARS-CoV-2 virus has led to the development of low-cost, efficient, and reliable methods for COVID-19 diagnosis over “gold standard” real-time reverse transcription-polymerase chain reaction (RT-PCR) due to its several limitations. This led to the development of electrochemical sensors/biosensors for rapid, fast, and low-cost detection of the SARS-CoV-2 virus from the patient’s biological fluids by detecting the components of the virus, including structural proteins (antigens), nucleic acid, and antibodies created after COVID-19 infection. This review comprehensively summarizes the state-of-the-art research progress of electrochemical biosensors for COVID-19 diagnosis. They include the detection of spike protein, nucleocapsid protein, whole virus, nucleic acid, and antibodies. The review also outlines the structure of the SARS-CoV-2 virus, different detection methods, and design strategies of electrochemical SARS-CoV-2 biosensors by highlighting the current challenges and future perspectives.
Collapse
|
18
|
Xu B, Tang H, Weng Y, Jones VS, Luo S, Cho CY, Lin Y, Fang J, Song X, Huang R. Development and evaluation of time-resolved fluorescent immunochromatographic assay for quantitative detection of SARS-CoV-2 spike antigen. J Clin Lab Anal 2022; 36:e24513. [PMID: 35692032 PMCID: PMC9279991 DOI: 10.1002/jcla.24513] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 03/28/2022] [Accepted: 04/25/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND The spread of COVID-19 worldwide caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has necessitated efficient, sensitive diagnostic methods to identify infected people. We report on the development of a rapid 15-minute time-resolved fluorescent (TRF) lateral flow immunochromatographic assay for the quantitative detection of the SARS-CoV-2 spike protein receptor-binding domain (S1-RBD). OBJECTIVES Our objective was to develop an efficient method of detecting SARS-CoV-2 within 15 min of sample collection. METHODS We constructed and evaluated a portable, disposable lateral flow device, which detected the S1-RBD protein directly in nasopharyngeal swab samples. The device emits a fluorescent signal in the presence of S1-RBD, which can be captured by an automated TRF instrument. RESULTS The TRF lateral flow assay signal was linear from 0 to 20 ng/ml and demonstrated high accuracy and reproducibility. When evaluated with clinical nasopharyngeal swabs, the assay was performed at >80% sensitivity, >84% specificity, and > 82% accuracy for detection of the S1-RBD antigen. CONCLUSION The new S1-RBD antigen test is a rapid (15 min), sensitive, and specific assay that requires minimal sample preparation. Critically, the assay correlated closely with PCR-based methodology in nasopharyngeal swab samples, showing that the detected S1-RBD antigen levels correlate with SARS-CoV-2 virus load. Therefore, the new TRF lateral flow test for S1-RBD has potential application in point-of-care settings.
Collapse
Affiliation(s)
| | - Hao Tang
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
| | | | | | - Shuhong Luo
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
| | | | - Yongping Lin
- The First Affiliated Hospital of Guangzhou Medical UniversityGuangzhouChina
| | - Jianmin Fang
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
| | | | - Ruo‐Pan Huang
- RayBiotech, GuangzhouGuangzhouChina
- RayBiotech LifePeachtree CornersGeorgiaUSA
- The First Affiliated Hospital of Guangzhou Medical UniversityGuangzhouChina
- South China Biochip Research CenterGuangzhouChina
| |
Collapse
|
19
|
Current Advances in Paper-Based Biosensor Technologies for Rapid COVID-19 Diagnosis. BIOCHIP JOURNAL 2022; 16:376-396. [PMID: 35968255 PMCID: PMC9363872 DOI: 10.1007/s13206-022-00078-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 07/06/2022] [Accepted: 07/22/2022] [Indexed: 12/29/2022]
Abstract
The global coronavirus disease 2019 (COVID-19) pandemic has had significant economic and social impacts on billions of people worldwide since severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first reported in Wuhan, China, in November 2019. Although polymerase chain reaction (PCR)-based technology serves as a robust test to detect SARS-CoV-2 in patients with COVID-19, there is a high demand for cost-effective, rapid, comfortable, and accurate point-of-care diagnostic tests in medical facilities. This review introduces the SARS-CoV-2 viral structure and diagnostic biomarkers derived from viral components. A comprehensive introduction of a paper-based diagnostic platform, including detection mechanisms for various target biomarkers and a COVID-19 commercial kit is presented. Intrinsic limitations related to the poor performance of currently developed paper-based devices and unresolved issues are discussed. Furthermore, we provide insight into novel paper-based diagnostic platforms integrated with advanced technologies such as nanotechnology, aptamers, surface-enhanced Raman spectroscopy (SERS), and clustered regularly interspaced short palindromic repeats (CRISPR)-Cas. Finally, we discuss the prospects for the development of highly sensitive, accurate, cost-effective, and easy-to-use point-of-care COVID-19 diagnostic methods.
Collapse
|