1
|
Aydın EB, Aydın M, Sezgintürk MK. A new immunosensing platform based on conjugated Poly(ThidEp-co-EDOT) copolymer for resistin detection, a new obesity biomarker. Mikrochim Acta 2024; 191:69. [PMID: 38165489 DOI: 10.1007/s00604-023-06145-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 12/09/2023] [Indexed: 01/03/2024]
Abstract
The design of a novel electrochemical impedimetric biosensor for label-free analysis of resistin, a biomarker for obesity, is reported. For the fabrication of the immunosensor, a novel approach composed of electrochemical copolymerization of double epoxy groups-substituted thiophene (ThidEp) and 3,4-Ethylenedioxythiophene (EDOT) monomers was utilized. Anti-resistin antibodies were covalently attached to the copolymer-coated electrode. The capture of resistin antigens by anti-resistin antibodies caused significant variations in charge transfer resistance (Rct) because of the immunoreactions between these proteins. Under optimum experimental variables, the changes in impedance signals were employed for the determination of resistin antigen concentration, and the prepared immunosensor based on conjugated copolymer illustrated a wide linear range between 0.0125 and 22.5 pg/mL, a low detection limit (LOD) of 3.71 fg/mL, and a good sensitivity of 1.22 kΩ pg-1mL cm2. The excellent analytical performance of the resistin immunosensor in terms of selectivity, sensitivity, repeatability, reproducibility, storage stability, and low detection limit might be attributed to the conductive copolymer film layer generation on the disposable indium tin oxide (ITO) platform. The capability of this system for the determination of resistin in human serum and saliva samples was also tested. The immunosensor results were in accordance with the enzyme-linked immunosorbent assay (ELISA) results. The matrix effects of human serum and saliva were also investigated, and the proposed immunosensor displayed good recovery ranging from 95.91 to 106.25%. The engineered immunosensor could open new avenues for obesity monitoring.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Tekirdağ, Turkey.
| | - Muhammet Aydın
- Scientific and Technological Research Center, Tekirdağ Namık Kemal University, Tekirdağ, Turkey
| | - Mustafa Kemal Sezgintürk
- Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| |
Collapse
|
2
|
Bankole OE, Verma DK, Chávez González ML, Ceferino JG, Sandoval-Cortés J, Aguilar CN. Recent trends and technical advancements in biosensors and their emerging applications in food and bioscience. FOOD BIOSCI 2022. [DOI: 10.1016/j.fbio.2022.101695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
3
|
Joshi H, Kandari D, Maitra SS, Bhatnagar R. Biosensors for the detection of Mycobacterium tuberculosis: a comprehensive overview. Crit Rev Microbiol 2022; 48:784-812. [PMID: 35196464 DOI: 10.1080/1040841x.2022.2035314] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Tuberculosis (TB) infection is one of the leading causes of death in the world. According to WHO reports 2019, the average rate of decrease in global TB incidences was only 1.6% per year from 2000 to 2018, besides that the global decline in TB deaths was just 11%. Therefore, the dire need for early detection of the pathogen for the successful diagnosis of TB seems justified. Mycobacterium tuberculosis secretory proteins have gained more attention as TB biomarkers, for the early diagnosis and treatment of TB. Here in this review, we elaborate on the recent advancements made in the field of piezoelectric, magnetic, optical, and electrochemical biosensors, in addition to listing their merits and setbacks. Additionally, this review also discusses the construction of biosensors through modern integrated technologies, such as combinations of analytical chemistry, molecular biology, and nanotechnology. Integrated technologies enhance the detection for perceiving highly selective, specific, and sensitive signals to detect M. tuberculosis. Furthermore, this review highlights the recent challenges and scope of improvement in numerous biosensors developed for rapid, specific, selective, and sensitive detection of tuberculosis to reduce the TB burden and successful treatment.
Collapse
Affiliation(s)
- Hemant Joshi
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India
| | - Divya Kandari
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India
| | - Subhrangsu Sundar Maitra
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India
| | - Rakesh Bhatnagar
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India.,Amity University of Rajasthan, Jaipur, India
| |
Collapse
|
4
|
Revisiting Some Recently Developed Conducting Polymer@Metal Oxide Nanostructures for Electrochemical Sensing of Vital Biomolecules: A Review. JOURNAL OF ANALYSIS AND TESTING 2022. [DOI: 10.1007/s41664-022-00209-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
5
|
Zouaoui F, Zine N, Errachid A, Jaffrezic‐Renault N. Mathematical Model and Numerical Simulation of Conductometric Biosensor of Urea. ELECTROANAL 2022. [DOI: 10.1002/elan.202100610] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Fares Zouaoui
- University of Lyon Institute of Analytical Sciences UMR 5280 CNRS 69100 Villeurbanne France
| | - Nadia Zine
- University of Lyon Institute of Analytical Sciences UMR 5280 CNRS 69100 Villeurbanne France
| | - Abdelhamid Errachid
- University of Lyon Institute of Analytical Sciences UMR 5280 CNRS 69100 Villeurbanne France
| | | |
Collapse
|
6
|
Baluta S, Meloni F, Halicka K, Szyszka A, Zucca A, Pilo MI, Cabaj J. Differential pulse voltammetry and chronoamperometry as analytical tools for epinephrine detection using a tyrosinase-based electrochemical biosensor. RSC Adv 2022; 12:25342-25353. [PMID: 36199318 PMCID: PMC9446417 DOI: 10.1039/d2ra04045j] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 09/01/2022] [Indexed: 12/20/2022] Open
Abstract
The main goal of the presented study was to design a biosensor-based system for epinephrine (EP) detection using a poly-thiophene derivative and tyrosinase as a biorecognition element. We compared two different electroanalytical techniques to select the most prominent technique for analyzing the neurotransmitter. The prepared biosensor system exhibited good parameters; the differential pulse (DPV) technique presented a wide linear range (1–20 μM and 30–200 μM), with a low detection limit (0.18 nM and 1.03 nM). In the case of chronoamperometry (CA), a high signal-to-noise ratio and lower reproducibility were observed, causing a less broad linear range (10–200 μM) and a higher detection limit (125 nM). Therefore, the DPV technique was used for the calculation of sensitivity (0.0011 μA mM−1 cm−2), stability (49 days), and total surface coverage (4.18 × 10−12 mol cm−2). The biosensor also showed very high selectivity in the presence of common interfering species (i.e. ascorbic acid, uric acid, norepinephrine, dopamine) and was successfully applied for EP determination in a pharmaceutical sample. GCE/poly-4,4′-bBT/tyrosinase biosensor for epinephrine was constructed. Comparison of differential pulse voltammetry (DPV) and chronoamperometry was performed. DPV showed more reproducible results giving high selectivity, sensitivity, stability.![]()
Collapse
Affiliation(s)
- Sylwia Baluta
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Francesca Meloni
- Department of Chemistry and Pharmacy, University of Sassari, Via Vienna 2, 07100 Sassari, Italy
| | - Kinga Halicka
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Adam Szyszka
- Faculty of Microsystem Electronics and Photonics, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Antonio Zucca
- Department of Chemistry and Pharmacy, University of Sassari, Via Vienna 2, 07100 Sassari, Italy
| | - Maria Itria Pilo
- Department of Chemistry and Pharmacy, University of Sassari, Via Vienna 2, 07100 Sassari, Italy
| | - Joanna Cabaj
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| |
Collapse
|
7
|
Ahumada JC, Soto JP, Alemán C, Torras J. Synthesis and characterization of a new benzobisoxazole/thiophene derivative polymer and the effect of the substituent on the push/pull properties. JOURNAL OF POLYMER SCIENCE 2021. [DOI: 10.1002/pol.20210566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Juan Carlos Ahumada
- Departamento de Química Universidad Técnica Federico Santa María Valparaíso Chile
- Department of Chemical Engineering and Barcelona Research Center for Multiscale Science and Engineering Universitat Politècnica de Catalunya, Escola d'Enginyeria de Barcelona Est (EEBE) Barcelona Spain
| | - Juan Pablo Soto
- Laboratorio de Polímeros, Instituto de Química Facultad de Ciencias, Pontificia Universidad Católica de Valparaíso Valparaíso Chile
| | - Carlos Alemán
- Department of Chemical Engineering and Barcelona Research Center for Multiscale Science and Engineering Universitat Politècnica de Catalunya, Escola d'Enginyeria de Barcelona Est (EEBE) Barcelona Spain
| | - Juan Torras
- Department of Chemical Engineering and Barcelona Research Center for Multiscale Science and Engineering Universitat Politècnica de Catalunya, Escola d'Enginyeria de Barcelona Est (EEBE) Barcelona Spain
| |
Collapse
|
8
|
Urbanowicz M, Sadowska K, Paziewska-Nowak A, Sołdatowska A, Pijanowska DG. Highly Stable Potentiometric (Bio)Sensor for Urea and Urease Activity Determination. MEMBRANES 2021; 11:membranes11110898. [PMID: 34832127 PMCID: PMC8623495 DOI: 10.3390/membranes11110898] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 11/10/2021] [Accepted: 11/18/2021] [Indexed: 11/23/2022]
Abstract
There is growing interest for bioanalytical tools that might be designed for a specific user, primarily for research purposes. In this perspective, a new, highly stable potentiometric sensor based on glassy carbon/polyazulene/NH4+-selective membrane was developed and utilized for urease activity determination. Urease–urea interaction studies were carried out and the Michaelis–Menten constant was established for this enzymatic reaction. Biofunctionalization of the ammonium ion-selective sensor with urease lead to urea biosensor with remarkably good potential stability (drift coefficient ~0.9 mV/h) and short response time (t95% = 36 s). The prepared biosensor showed the Nernstian response (S = 52.4 ± 0.7 mV/dec) in the urea concentration range from 0.01 to 20 mM, stable for the experimental time of 60 days. In addition, some insights into electrical properties of the ion-to-electron transducing layer resulting from impedance spectroscopy measurements are presented. Based on the RCQ equivalent circuits comparison, it can be drawn that the polyazulene (PAz) layer shows the least capacitive behavior, which might result in good time stability of the sensor in respect to response as well as potential E0. Both the polyazulene-based solid-contact ion selective electrodes and urea biosensors were successfully used in trial studies for determination of ammonium ion and urea in human saliva samples. The accuracy of ammonium ion and urea levels determination by potentiometric method was confirmed by two reference spectrophotometric methods.
Collapse
|
9
|
Potentiometric urea biosensors. Clin Chim Acta 2021; 524:154-163. [PMID: 34774544 DOI: 10.1016/j.cca.2021.11.011] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 11/04/2021] [Accepted: 11/08/2021] [Indexed: 12/17/2022]
Abstract
Excess nitrogen in the body is converted to urea in the liver, and urea is disposed as a waste product in urine. Urea concentration can change in body fluids such as blood due to the presence of certain disorders. Therefore, the determination of urea is of high importance in various areas including medical diagnosis, as well as food quality control and environmental monitoring. Potentiometric sensors have certain advantages over their alternatives, such as rapidity, portability, cost effectiveness, high sensitivity, easy operation and simple apparatus. Potentiometric urea biosensors based on enzyme urease have been developed using various materials including nanoparticles and films, and also using different methodologies. In this review, we covered potentiometric urea biosensors reported in the literature, and touched upon their certain structure characteristics and performance parameters including detection limit, working concentration range, response time and lifetime, all of which are of practical importance. Each potentiometric urea biosensor has its own advantages and drawbacks, thus the selection of appropriate method depends on the sample to be analyzed, its urea concentration range and other requirements of the particular application. Further research is needed in order to optimize the performance of these devices and to broaden their applicability.
Collapse
|
10
|
Asav E. Development of a functional impedimetric immunosensor for accurate detection of thyroid-stimulating hormone. Turk J Chem 2021; 45:819-834. [PMID: 34385869 PMCID: PMC8329345 DOI: 10.3906/kim-2012-69] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 03/26/2021] [Indexed: 12/03/2022] Open
Abstract
Thyroid-stimulating hormone (TSH), which regulates the synthesis of thyroid gland hormones affecting the whole metabolism, is a pituitary hormone. Determination of TSH is crucial for monitoring thyroid gland-related disorders and some metabolic diseases.In this study, a nonlabeled immunosensor based on covalent immobilization of anti-TSH antibody by using the formation of self-assembled monolayers (SAM) of 4-mercaptophenylacetic acid (4-MPA) and functionalization of carboxyl ends with 1-ethyl-3-(3-dimetilaminopropil) carbodiimide (EDC)/N-Hydroxysuccinimide (NHS) was fabricated for detection of TSH. Immobilization steps including the concentration of 4-MPA, the concentration of anti-TSH antibody, and duration of anti-TSH antibody incubation were optimized by utilizing electrochemical impedance spectroscopy. Under optimal conditions, a sensitive, rapid, and accurate determination of TSH at a concentration range between 0.7 and 3.5 mIU/L was accomplished with a notable linearity and LOD value of 0.034 mIU/L, as well as reproducibility and repeatability. Moreover, for comparison, linear range experiments were also carried out by using other electrochemical methods, including linear sweep voltammetry, cyclic voltammetry, and capacitance spectroscopy. Finally, the constructed immunosensor was used for analyzing TSH levels spiked in the artificial serum samples.
Collapse
Affiliation(s)
- Engin Asav
- Department of Nutrition and Dietetics, School of Health, Kırklareli University Turkey
| |
Collapse
|
11
|
Bulla SS, Bhajantri RF, Chavan C, Sakthipandi K. Synthesis and characterization of polythiophene/zinc oxide nanocomposites for chemiresistor organic vapor-sensing application. JOURNAL OF POLYMER RESEARCH 2021. [DOI: 10.1007/s10965-021-02618-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
12
|
Singh S, Sharma M, Singh G. Recent advancements in urea biosensors for biomedical applications. IET Nanobiotechnol 2021; 15:358-379. [PMID: 34694714 PMCID: PMC8675831 DOI: 10.1049/nbt2.12050] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 01/06/2021] [Accepted: 02/14/2021] [Indexed: 12/22/2022] Open
Abstract
The quick progress in health care technology as a recurrent measurement of biochemical factors such as blood components leads to advance development and growth in biosensor technology necessary for effectual patient concern. The review wok of authors present a concise information and brief discussion on the development made in the progress of potentiometric, field effect transistor, graphene, electrochemical, optical, polymeric, nanoparticles and nanocomposites based urea biosensors in the past two decades. The work of authors is also centred on different procedures/methods for detection of urea by using amperometric, potentiometric, conductometric and optical processes, where graphene, polymer etc. are utilised as an immobilised material for the fabrication of biosensors. Further, a comparative revision has been accomplished on various procedures of urea analysis using different materials-based biosensors, and it discloses that electrochemical and potentiometric biosensor is the most promise one among all, in terms of rapid response time, extensive shelf life and resourceful design.
Collapse
Affiliation(s)
- Saravjeet Singh
- Department of Biomedical EngineeringDeenbandhu Chhotu Ram University of Science and TechnologyMurthalSonepatIndia
| | - Minakshi Sharma
- Department of ZoologyMaharishi Dayanand UniversityRohtakHaryanaIndia
| | - Geeta Singh
- Department of Biomedical EngineeringDeenbandhu Chhotu Ram University of Science and TechnologyMurthalSonepatIndia
| |
Collapse
|
13
|
Botewad SN, Gaikwad DK, Girhe NB, Thorat HN, Pawar PP. Urea biosensors: A comprehensive review. Biotechnol Appl Biochem 2021; 70:485-501. [PMID: 33847399 DOI: 10.1002/bab.2168] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 04/02/2021] [Indexed: 01/11/2023]
Abstract
Present study is specially designed for the recent advances in biosensors to detect and quantify urea concentration. Urea (carbamide) is an organic compound made up of the carbonyl (C=O) functional group with two -NH2 groups having chemical formula CO (NH2 )2 . In nature, urea is found everywhere as the result of various processes, and in the human body, urea is an end product of nitrogen metabolism. An excessive concentration of urea in the human body is responsible for different critical diseases such as indigestion, acidity, ulcers, cancer, malfunctioning of kidneys, renal failure, urinary tract obstruction, dehydration, shock, burns, gastrointestinal bleeding, and so on. Moreover, below the normal level may cause hepatic failure, nephritic syndrome, cachexia, and so on. As well as in various fields such as fishery, dairy, food preservation, agriculture, and so on, urea is normally found and its detection is necessary. In urea biosensors, enzyme urease (Urs) is used as a bioreceptor element and retains its long last activity is the critical issue in front of the researcher. During recent decades, different nanoparticles (zinc oxide, nickel oxide, iron oxide, titanium dioxide, tin(IV) oxide, etc.), conducting polymer (polyaniline, polypyrrole, etc.), conducting polymer-nanoparticles composites, carbon materials (carbon nanotubes, graphene oxide, reduced graphene oxide graphene), and so on are used in urea biosensors. The main emphasis of the present study is to provide cumulative and comprehensive information about the sensing parameters of urea biosensors based on the materials used for enzyme immobilization. Besides this special task, this review provides a fruitful discussion on the basics of biosensors briefly for new and upcoming researchers. Thus, the present study may act as a gift for a large audience that come from different fields and are working in biosensors research.
Collapse
Affiliation(s)
- Sunil N Botewad
- Department of Physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad, Maharashtra, India
| | | | - Nitin B Girhe
- Jawahar Science, Commerce and Arts College, Andoor, Tq. Tuljapur District, Osmanabad, India
| | - Hanuman N Thorat
- Department of Physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad, Maharashtra, India
| | - Pravina P Pawar
- Department of Physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad, Maharashtra, India
| |
Collapse
|
14
|
Öndeş B, Akpınar F, Uygun M, Muti M, Aktaş Uygun D. High stability potentiometric urea biosensor based on enzyme attached nanoparticles. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105667] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
15
|
Enzyme activity of thiophene-fluorene based-copolymer blended with urease in thin films. Colloids Surf A Physicochem Eng Asp 2020. [DOI: 10.1016/j.colsurfa.2020.125139] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
16
|
Abstract
PURPOSE OF REVIEW Hypertension (HTN) and chronic kidney disease (CKD) are significant problems. With recent advances in technologies, biosensors have shown a great potential to provide better home monitoring in hypertension (HTN), medication compliance, diagnostic device for kidney disease, CKD/end-stage renal disease (ESRD) care, and post kidney transplant management. RECENT FINDINGS Multiple devices/biosensors have been developed related to HTN, kidney function including real-time glomerular filtration rate, CKD/end-stage renal disease, and transplant care. In recent advances in wearable biosensors, point of care monitoring system could provide more integrated care to the patients via telenephrology. SUMMARY This review focuses on the recent advances in biosensors which may be useful for HTN and nephrology. We will discuss future potential clinical implication of these biosensors.
Collapse
|
17
|
Dakshayini B, Reddy KR, Mishra A, Shetti NP, Malode SJ, Basu S, Naveen S, Raghu AV. Role of conducting polymer and metal oxide-based hybrids for applications in ampereometric sensors and biosensors. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.061] [Citation(s) in RCA: 134] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
18
|
Artigues M, Oh S, Gilabert-Porres J, Abellà J, Borrós S, Colominas S. Novel grafted electrochemical interface for covalent glucose oxidase immobilization using reactive pentafluorophenyl methacrylate. Colloids Surf B Biointerfaces 2019; 175:1-9. [PMID: 30508760 DOI: 10.1016/j.colsurfb.2018.11.076] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 10/24/2018] [Accepted: 11/27/2018] [Indexed: 11/19/2022]
Abstract
One of the most important factors for the proper functioning of enzymatic electrochemical biosensors is the enzyme immobilization strategy. In this work, glucose oxidase was covalently immobilized using pentafluorophenyl methacrylate (PFM) by applying two different surface modification techniques (plasma polymerization and plasma-grafting). The grafted surface was specifically designed to covalently anchor enzyme molecules. It was observed using QCM-D measurements the PFM plasma-grafted surfaces were able to retain a higher number of active enzyme molecules than the PFM polymerized surfaces. An amperometric glucose biosensor using titanium dioxide nanotubes array (TiO2NTAs) modified by PFM plasma-grafted surface was prepared. The resulting biosensor exhibited a fast response and short analysis time (approximately eight minutes per sample). Moreover, this biosensor achieved high sensitivity (9.76 μA mM-1) with a linear range from 0.25 to 1.49 mM and a limit of detection (LOD) equal to 0.10 mM of glucose. In addition, the glucose content of 16 different food samples was successfully measured using the developed biosensor. The obtained results were compared with the respective HPLC value and a deviation smaller than 10% was obtained in all the cases. Therefore, the biosensor was able to overcome all possible interferences in the selected samples/matrices.
Collapse
Affiliation(s)
- Margalida Artigues
- Electrochemical Methods Laboratory - Analytical and Applied Chemistry Department at Institut Químic de Sarrià, Universitat Ramon Llull, Via Augusta, 390, 08017, Barcelona, Spain
| | - Sejin Oh
- Grup d'Enginyeria de Materials (GEMAT) at Institut Químic de Sarrià, Universitat Ramon Llull, Via Augusta, 390, 08017, Barcelona, Spain
| | - Joan Gilabert-Porres
- Grup d'Enginyeria de Materials (GEMAT) at Institut Químic de Sarrià, Universitat Ramon Llull, Via Augusta, 390, 08017, Barcelona, Spain
| | - Jordi Abellà
- Electrochemical Methods Laboratory - Analytical and Applied Chemistry Department at Institut Químic de Sarrià, Universitat Ramon Llull, Via Augusta, 390, 08017, Barcelona, Spain
| | - Salvador Borrós
- Grup d'Enginyeria de Materials (GEMAT) at Institut Químic de Sarrià, Universitat Ramon Llull, Via Augusta, 390, 08017, Barcelona, Spain; CIBER-BBN, Networking Center on Bioengineering, Biomaterials and Nanomedicine, Zaragoza, Spain
| | - Sergi Colominas
- Electrochemical Methods Laboratory - Analytical and Applied Chemistry Department at Institut Químic de Sarrià, Universitat Ramon Llull, Via Augusta, 390, 08017, Barcelona, Spain.
| |
Collapse
|
19
|
Lee KM, Kim KH, Yoon H, Kim H. Chemical Design of Functional Polymer Structures for Biosensors: From Nanoscale to Macroscale. Polymers (Basel) 2018; 10:E551. [PMID: 30966585 PMCID: PMC6415446 DOI: 10.3390/polym10050551] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 05/14/2018] [Accepted: 05/14/2018] [Indexed: 11/16/2022] Open
Abstract
Over the past decades, biosensors, a class of physicochemical detectors sensitive to biological analytes, have drawn increasing interest, particularly in light of growing concerns about human health. Functional polymeric materials have been widely researched for sensing applications because of their structural versatility and significant progress that has been made concerning their chemistry, as well as in the field of nanotechnology. Polymeric nanoparticles are conventionally used in sensing applications due to large surface area, which allows rapid and sensitive detection. On the macroscale, hydrogels are crucial materials for biosensing applications, being used in many wearable or implantable devices as a biocompatible platform. The performance of both hydrogels and nanoparticles, including sensitivity, response time, or reversibility, can be significantly altered and optimized by changing their chemical structures; this has encouraged us to overview and classify chemical design strategies. Here, we have organized this review into two main sections concerning the use of nanoparticles and hydrogels (as polymeric structures) for biosensors and described chemical approaches in relevant subcategories, which act as a guide for general synthetic strategies.
Collapse
Affiliation(s)
- Kyoung Min Lee
- Department of Polymer Engineering, Graduate School, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.
- Department of Materials Science and Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea.
| | - Kyung Ho Kim
- Department of Polymer Engineering, Graduate School, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.
| | - Hyeonseok Yoon
- Department of Polymer Engineering, Graduate School, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.
- School of Polymer Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.
| | - Hyungwoo Kim
- Department of Polymer Engineering, Graduate School, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.
- School of Polymer Science and Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea.
| |
Collapse
|
20
|
Jakhar S, Pundir C. Preparation, characterization and application of urease nanoparticles for construction of an improved potentiometric urea biosensor. Biosens Bioelectron 2018; 100:242-250. [DOI: 10.1016/j.bios.2017.09.005] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Revised: 09/01/2017] [Accepted: 09/04/2017] [Indexed: 10/18/2022]
|
21
|
Hassan RYA, Kamel AM, Hashem MS, Hassan HNA, Abd El-Ghaffar MA. A new disposable biosensor platform: carbon nanotube/poly(o-toluidine) nanocomposite for direct biosensing of urea. J Solid State Electrochem 2018. [DOI: 10.1007/s10008-017-3857-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
22
|
|
23
|
Pandey AK, Pandey PC, Agrawal NR, Das I. Synthesis and characterization of dendritic polypyrrole silver nanocomposite and its application as a new urea biosensor. J Appl Polym Sci 2017. [DOI: 10.1002/app.45705] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Avinash Kumar Pandey
- Chemistry Department; DDU Gorakhpur University; Gorakhpur 273009 Uttar Pradesh India
| | - Prem Chandra Pandey
- Chemistry Department; IIT Banaras Hindu University; Varanasi 221005 Uttar Pradesh India
| | - Namita Rani Agrawal
- Chemistry Department; St. Andrew's College; Gorakhpur 273001 Uttar Pradesh India
| | - Ishwar Das
- Chemistry Department; DDU Gorakhpur University; Gorakhpur 273009 Uttar Pradesh India
| |
Collapse
|